Entry & Exit Control Systems
SECURITECH
™
MAGLATCH ENTRY & EXIT CONTROL SYSTEMS systems are designed to provide fail-safe and failsecure protection, as determined by the specific user and respectful of local building codes. MAGLATCH functions through use of two integrated locking technologies: mechanical latching and electromagnetic locking. Customization is key. Here are a few systems and the discussion sheet. Sample Entry/Exit Control Systems: System
Door A, Corridor Side
Door A, Vestibule Side
Door B, Vestibule Side
Door B, Room Side
Notes
#101 Entry by key or buzzer if B Exit only if door B is closed
Entry by buzzer if A is closed
Exit only if Door A is closed
Person in the Mantrap can exit at anytime if door B is closed.
Fire Key required Alarm
Exit anytime
Key required
Exit anytime
During a fire alarm, both doors could open.
is closed
#102 Entry by key or buzzer if B Exit anytime
Entry by key or buzzer if Exit anytime A is closed
is closed
There is a possibillity of having both doors open at the same time.
This unit does not require connection to a fire alarm system. Installation of an alarm is recommended to sound if both doors open simultaneously.
# 103 Entry by key or buzzer if B Exit by key or buzzer is closed
Fire Key required Alarm
Exit by key or buzzer only if Door A is closed
This provides the option of locking someone in the Mantrap.
Exit anytime
Exit anytime
During a fire alarm, both doors could open.
Key required
Exterior
Interior
B
Direction Of Exit Travel
Lever Trim With F1 Free Moving Lever Electromagnetic Lock with bond sensor and door status switch
C
Lever Trim With F2 Free Moving Lever & 2 Switches
Mortise D1 Lock
G1
Mortise D2 Lock with latch position switch
Operation Information
Surface Vertical Rod Exit Device
Power Transfers
G2 RimExit Device
H K
Additional Items
made in usa by (800)622-5625
Lever Trim E1 With Electric & Key Release Lever Trim E2 With Electric & Key Release For Double-Sided Use
Push Button Release Console
Interior
Locking Elements
Direction Of Entry Travel
SECURITECH
Supply/ Controller
Protected Area
Mantrap Exterior
Entry Area
Door "B" (Inner Door)
A Power
TrimSelections
Door "A" (Outer Door)
SystemControl
MAGLATCH Entry/Exit Control SystemDiscussion Page
SECURITECH™ Sample 2 Door "Mantrap" System:
Entry by buzzer if A is only if door B is closed closed
Key Switch
I
J L
Pushbutton
SECURITECH GROUP, INC. 54-45 44th St. (718)392-9000 (718)392-8944 fax
M
N
Traffic Light Enclosure
Blue Pull Station
Maspeth, NY 11378 www.securitech.com