CAT 4900 2012

Page 1

MP4900™ Features

The Legal Way To Lock Emergency Exit Doors

MP4900™ Exit Police Lock & Exit Devices Offer: 4-Point Protection Against Break-Ins

Optional Alarms To Provide Notification

Easy Exiting To Meet Life Safety Codes

Quick, Simple Installation Onto Existing Doors

Manual, Self Locking & Fire-Rated Models

Full End-User Customization

Alarm Options

Stainless Steel Upper & Lower Deadbolts Are 5” Long & 5/8” in Dia.: Maximum Resistance To Prying

Direct Power Alarm, Single Door With

Steel Mounting Bracket Fastened To The Door With Two Hex-Head Bolts & Thru-Bolt Plate

Individual Key Switch & Door Module or Battery Operated Alarm

1/4”Diameter Threaded Rod Assures Smooth Operation Aluminum Channel Protects Rod & Bolt Against Abuse From Inside

Hinge-Side Steel Deadbolt Installs Easily To The Edge Of The Door ( Not Visible

2-3/4” Long & 3/4” Tall, Pry-Resistant Primary Stainless Steel Deadbolt

When The Door Is Closed)

Heavy-Duty 1/8” Heavy-duty 1/8” thick, Thick, 12” Long long anodized Anodized Aluminum aluminum paddle Paddle;

Alarm Signal Switch Initiated By Paddle Movement

Longer On Fire-Rated Units

Simultaneous Locking/Retraction Of All Deadbolts By Paddle

Non-Ferrous Dustproof Strike Is Mounted Into The Saddle Or Floor To Retard Dirt & Accept The Lower Bolt

Steel Encased Listed Mechanism

Safety & Security Alarmed Exit Locks were created to provide both safety and notification. Certain doors also needed protection against forced entry (security). It violates codes to add locks, burglar bars or any additional bolts to a door that would impede exiting or require “Special Knowledge” to operate. MP4900™ solves the Safety & Security problem by invisibly adding multi-point deadbolt protection to the standard alarmed exit lock operation. New Fire-Rated exit device models allow installation on interior doors. You don’t have to break the law or put people at risk to protect against break-ins.


MP4900™ Features Heavy-Duty Paddle In today’s world an exit lock needs to protect against break-ins without sacrificing safety. Emergency exit codes prevent installing secondary locks, burglar bars or slide bolts on doors with panic bars. Protecting emergency exits from break-ins should not make you break the law! Securitech™’s MP4900™ is the answer. It has stopped break-ins from NY to LA without breaking the law!

The MP4900™ shoots steel deadbolts from the door into the frame at four separate locations, yet depressing the paddle retracts them all at once. It’s the safety and security answer that satisfies both fire marshals and security directors. And it has more customizable features than any other exit lock. You design the model to meet your needs.

4-point, 3-point models available One action release or locking of all deadbolts Manual, self-locking and fire-rated models Double door models available Exit only or exterior entry by key Battery or hardwired alarms Single or multi-door alarms Extra signals for security system integration

“Toughest paddle in the industry” offers durability and easy-to-read emergency label. Optional Exterior Operation/Trim Stainless Steel Guard Plate For Manual Locking Models Vandal-Resistant Lever Trim For Self Locking Models. Key And/Or Electric Release Available. Anti-Pry Protection Laminated Thru-Bolt Plates For Top & Bottom Deadbolts

Stainless Steel Anti-Pry Thru-Bolt Plate For Primary Deadbolt Power Supplies And Alarms All Securitech™ exit devices are available with or without alarms. Options include battery or direct power with battery back-up, local or remote sirens, single door power supplies or units which can operate multiple doors. Custom alarms, power supplies, consoles or other elements can be created to meet special notification needs.

Customized models to meet specific end-user needs

54-45 44th Street Maspeth, NY 11378 www.securitech.com (718) 392-9000 (800) 622-LOCK Fax: (718) 392-8944


SECURITECH SOLUTIONS MODEL SELECTOR

Check local codes to determine requirements by opening

EASY MODEL NUMBER CREATOR 4945 - ML - XX - A10 - FSP - ___

ALL MP PANIC EXIT LOCKS & DEVICES BEGIN WITH "49"

SIZE, SPECIAL NOTES

LOCKING POINTS

SPECIAL OPTIONS

LOCKING METHOD

ALARM & ALARM CYLINDER OPTIONS

EXTERIOR OPERATION

1 Locking Points

2 Locking Method

SINGLE DOOR

DOUBLE DOORS

4945

GATES

4935P

2-Pt. (top & horizontal bolt)

3 Exterior Entry Options

-XX is exit only model

ML -Single Door Cylinder: PC-regular PRML-Double Door Cylinder: PH-regular PB-

OTHERS

4922

3-Pt. per door (no horizontal bolt)

4-Pt.

TG

FIRE-RATED DEVICE

ML

4932

FD

SL

4933

3a PC or PH

PR, PB or BF

RC Rim cylinder

BC Removable core rim cylinder

ML-Gate BF

LL - key activated lever trim LA - key or AC release LD - key or DC release

Easy-to operate thumbpiece TG is for ML single or double

EXIT LOCKS

4931

SL or FD -Single Or Double Door

4

TG, LL, LA, LD

removable core CF- classroom function cylinder, no pull handle LQ - quick-connect wiring Cylinder not provided, unless ordered as an option (see 3a)

MC Mortise cylinder NC Removable core mortise cyl.

All alarms are wall-mounted; key momentarily silences and resets alarm

No Alarm

Battery Powered

AG0 No alarm or signal MSO

110v AC Powered

A10 9v battery included

-L Last Door Out -B Battery Saver

5 SB Strike Bracket (mount on inactive door of a pair)

Additional ordering information:

SL & FD MODELS REQUIRE DOOR SIZE. SPECIFY DOOR WIDTH IF OVER 40”

AG3

Single Door Alarm

Door module #DM1 (No local siren)

AG3DS

AG4

Door module, local siren and keyswitch

Key switch only alarm ordered Keyswitch for Requires single with GelCel AG2 or AG3 separately battery back-up gang box Mortise cylinder not provided, unless ordered as an option EBT

BUP

Extra Bracket & Thru-Bolt Plate PE Paddle Extension (If required by code)

Manual Locking: Shipped for 3’x7’ doors. Can be field cut for shorter. Specify size if taller.

SECURITECH GROUP, INC.

Door Elements For Multi-Door Alarm System

AG2

Single door or multidoor alarm to be determined later:

Stainless Steel (4”x8”) Bolt Underplate For Extra Reinforcement

FSP Set of 2 Stainless Steel Plates (4”x4”) & Brackets

CT Digital Counter

(718)392-9000

OA Keyswitch turns alarms on/off for extended periods Cylinder: Use nomenclature MC or NC (from 3a)

Multi-Door Alarm

Order separately

#49DPS-5

(monitors door usage)

CADA Set of 1 Paddle Extension 1 Paddle Deflector 1 Channel Deflector (See photos on rear)

Self-Locking & Fire Rated: Shipped for 3’x7’ doors. Can be field adjusted downward to 79“ height. Specify height if taller than 84”or less than 79”. If exterior operation is ordered, LHR or RHR must be designated.

(800)622-LOCK

4a

(718)392-8944 fax

Will operate up to 5 doors. Add “AG3” or “AG4” designation to each door lock for operation.

#49DM1 For use with each “AG4” connected to #49DPS5 www.securitech.com


MP4900™ Alarm Options All alarms are wall mounted, not door mounted. In the event that a door is opened and the alarm sounds, the siren will blare within the facility, not to the outside. Alarms or key switch boxes are connected to the locking mechanism via a stainless steel armored cable.

A10 Battery Operated ■ ■ ■ ■ ■ ■

Operates off one 9volt battery Momentary key switch function (key used to shunt alarm) Optional battery saver feature Key cannot be removed unless door is locked Optional lithium 9volt battery for extended life Optional last door out for entry/exit door with exterior key control ■ On/Off key switch option ■ Mortise cylinder for alarm control (By Others) 9volt Battery

AG2 Direct Power, Single Door ■ Hardwired for reliable operation 110v direct power connection ■ Twin 110db siren ■ GelCel battery battery back-up; Projected life of 5 years ■ Momentary key switch function ■ Siren mounted within power supply ■ Optional remote signalling capability ■ LED indicates alarm activation ■ Mortise cylinder for alarm control (By Others) ■ Includes direct power supply/alarm unit and s e p a r a t e key switch box

Power Supply

GelCel Battery

AG3 Individual Key Switch & Door Module ■ To be used with 49DPS-5 door alarm ■ Optional LED Indicator to show alarm is activated ■ Provides alarm sound and LED indication at remote power supply location when activated ■ Optional siren at door ■ Mortise cylinder for alarm control (By Others)

#49DPS-5: Separate Power Supply & Alarm For Up To 5 Doors ■ ■ ■ ■ ■

Install at central location within store or facility Separate LEDs indicate status of each door Locks are ordered “AG3” Momentary key switch & module installed at each door to reset alarm Optional siren at door