Offshore Kabloları Rusça Ürün Kataloğu

Page 1










Ka6en1ı1 AnJI MOpCKlı1X o6beKTOB

RFOU (NEK SOS P�] KA6Enb cııınosoııı, 6E3rAnorEHHbll/l, MAnO,QblMHbll/l, HEPACnPOCTPAHHIOL.Lılıllll roPEHlılE HALOGEN FREE, LOW SMOKE DENSITY, FLAME RETARDANT PO WER CABLE

CTPYKTYPA KA6Eml 1- nPOBO,QHlı1K

: CKpy4eHHbıııı npoBOAHIIIK 1113 311eKTpo11111r1114ecKoııı ny>KeHoııı MeAIII Knacca 2 IEC 60228 (Knacca 5 - no 3anpocy)

2- lı13Onfll-llı1fl

: 6e3ra11oreHHaR 3T11111eHnpon11111eH0BaR pe3111Ha

3- 3AnonHlı1TEnb

: 6e3ra11oreHHbllll KOMnayHA

4- 3KPAH

: 3KpaH111pyıou..ıaR onnerKa 1113 ny>KeHoııı 311eKrpo11111rn4ecKoııı MeA111 (noKpbırne 90%).

5- BHEWHflfl O6OnO4KA : SH2, 4epHbllll

CABLE STRUCTURE 1- CONDUCTOR

: Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request).

2- INSULATION

: Halogen free EPR ar Halogen free HEPR

3-BEDDING

: Halogen free compound.

4-SCREEN

: Electrolytic, tinned copper braided screen ( 90% coverage ).

5- OUTER SHEATH

: SHF2, 8/ack

CTAH,QAPTbl nPOlı13B0,[\CTBA lı1 TECTlılPOBAHlılfl / PRODUCTION AND TEST STANDARDS CTPYKTYPA / CONSTRUCT/ON tı1cnblTAHlı1fl lı1 MATEPlı1Anbl / TESTS AND MA TER/AL HEPAcnPOCTPAHEHlı1E rDPEHlılfl / FLAME RETARDATION CO,QEPi'KAHlı1E rAnOrEHA / HALOGEN CONTENT nnOTHOCTb ,QblMA / SMOKE DENSITY PA6O4Afl TEMnEPATYPA / WORKING TEMPERATURE Mlı1H.PA,Qlı1YC lı13rlı16A(<Dlı1KClı1P.) / MIN. BENDING RADIUS (FIXED) HOMlı1HAnbHOE HAnPfli'KEHlı1E / RA TED VOLTAGE tı1cnblTATEnbHOE HAnPfli'KEHlı1E / TEST VOLTAGE

: : : : : : : : :

NEK 606 P1, IEC 60092/353 IEC 60092 /350-351-359 IEC 60332 /1, IEC 60332 / 3 Cat A IEC 60754 / 1 - 2 IEC 61034 / 1-2 ( DiN EN 50268/1-2) -40°( / + 90°( (Hapy>KHbııii AVlaMeTp) x 8 x(overall diameter) 0,6/1 kV 3,5 kV

nPlı1MEHEHlı1E

APPL/CA TION

Craı..ı1110HapHbllll Ka6enb A11R n111TaHIIIR, ynpasneHIIIR 111 ocseu..ıeH111R.

Fixed installation cable for power, control and lighting.

YCnOBlılfl 3KCnnYATAL..llıllı1

ENVIRONMENT

lı1cnonb3YeTCR np111 nıo6bıx MOpCKIIIX yc11OB111Rx, TaKIIIX Usable at ali conditions in marine environment such KaK cyx111e, sna>KHbıe 11111111 Macno-Heq>Te3arpR3HeHHbıe Mecra. as dry, wet ar oily Jocations.

6E30nACHOCTb

SAFETY

611aroAapR CBOIIIM CBOIIICTBaM HeCOAep>KaHIIIR ranoreHa 111 HepacnpocrpaHeHIIIR ropeHIIIR, OH He BblAenReT Kopp03111pyıou..ı111e ra3bl III npeAOTBpau..ıaer AallbHeıııwee pacnpocrpaHeH111e orHR, 4TO 3au..ı111u..ıaer 4e11ose4ecKYıo

Due ta its' ha/ogen free and f/ame retardant features, it won't create corrosive gases and prevents the fire from spreading around. Thus it protects human life and equipment, during a fire. Low smoke density reduces the risk of smoke suffocation and keeps visibility around the fire zone.

>Klll3Hb 111 06opyAOBaH111e. H1113KaR nnoTHOCTb AblMa yMeHbwaeT plllCK YAYWeHIIIR OT AblMa 111 06ecne4111saeT BIIIAIIIMOCTb BOKpyr 3OHbl orHR.

••• •••

fmııl

FR 72-01 O I REV. O REV. TAR. 01 .05.201 O I Si. 1/3