American Aerospace AAC-Catalog

Page 1

CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

SF CATALOG

705

Current Voltage Power & Frequency Transducers

PAGE

1 OF 12

BI-DIRECTIONAL CURRENT TRANSDUCERS

Series No.

PROVIDE AN ISOLATED BI-POLAR OUTPUT DIRECTLY PROPORTIONAL TO THE INPUT CURRENT. THE OUTPUT SIGNAL TRACTS THE INPUT CURRENT WAVEFORM AND RECREATES ALMOST ANY AC, DC, TRANSIENT OR COMPLEX CURRENT COMBINATION.

905B 909M4 926 929 943 944 947 948 9000 S273 S449 S630 S651 S661B S745 S764 S784

DC CURRENT TRANSDUCERS

Series No.

MONITOR DC CURRENT BY PROVIDING A MAGNETICALLY ISOLATED ANALOG OUTPUT THAT IS DIRECTLY PROPORTIONAL TO THE INPUT. LOW CURRENT RANGES ARE AVAILABLE FOR DIFFERENTIAL AND GROUND FAULT CURRENT MONITORING.

903B 904B 913A 913B 920 921 936 950 952 DCT S218 S347 S444 S465 S619 S646 S728B S767 S770

DC CURRENT DETECTORS COMPARES THE DC INPUT TO A FIXED OR ADJUSTABLE CURRENT LIMIT. THE OUTPUT IS AN ISOLATED SWITCH OR RELAY THAT ACTIVATES AS REQUIRED. DC CURRENT DETECTORS ARE SUITED FOR GROUND FAULT CURRENT MONITORING.

Series No.

AC CURRENT TRANSDUCERS

Series No.

MAINTAIN ISOLATION AND PROVIDE AN ANALOG DC OUTPUT DIRECTLY PROPORTIONAL TO AC INPUT CURRENT. TRUE-RMS AND AVERAGE RESPONDING PRODUCTS ARE AVAILABLE IN CLAMP-ON AND PASS-THRU CONFIGURATIONS.

1001 1002M1 1003AM1 1003AM2 1004 1005 1006 1006X 1055 1055L 1070 ACT ACTS C CX S383 S383L S402 S461 S714 S786

AC CURRENT DETECTORS COMPARES THE AC INPUT TO A FIXED OR ADJUSTABLE CURRENT LIMIT. THE OUTPUT IS AN ISOLATED SWITCH OR RELAY THAT IS ACTIVATED AS REQUIRED. PRODUCTS AVAILABLE IN CLAMP-ON AND PASS-THRU CONFIGURATIONS.

AC VOLTAGE TRANSDUCERS PRODUCE AN ISOLATED ANALOG OUTPUT SIGNAL DIRECTLY PROPORTIONAL TO AC VOLTAGE AT A VARIETY OF FREQUENCIES. HIGH SENSITIVITY VERSIONS ARE AVAILABLE WITH ZERO SUPPRESSED AC INPUT VOLTAGE RANGES.

DC VOLTAGE TRANSDUCER & DETECTOR SERIES S657 PRODUCES AN ISOLATED ANALOG OUTPUT PROPORTIONAL TO DC VOLTAGE. SERIES S631 COMPARES THE DC INPUT TO AN ADJUSTABLE THRESHOLD. THE OUTPUT IS AN ISOLATED RELAY THAT ACTIVATES AS REQUIRED.

AC POWER TRANSDUCERS PROVIDES AN ISOLATED ANALOG DC OUTPUT DIRECTLY PROPORTIONAL TO AC INPUT POWER. TRUE POWER (WATTS) AND VOLT-AMP-REACTIVE (VAR) TRANSDUCERS ARE AVAILABLE FOR A VARIETY OF POWER RANGES AND FREQUENCIES.

FREQUENCY TRANSDUCERS PROVIDES AN ISOLATED ANALOG DC OUTPUT SIGNAL DIRECTLY PROPORTIONAL TO AC INPUT FREQUENCY. MANY RANGES ARE AVAILABLE, STARTING AT 5 TO 100HZ AND ALL THE WAY UP TO 1K TO 20KHZ.

901B S58 S201 S204 S623 S629 S680 S754

Series No.

870 871 880B 881 882 ACS ACS-3 ACS-SC S212

Series No.

101M3 102M3 105 108 108X V VX S190

Series No.

S631 S657

Series No.

415A 416A S73 S217 W&Q

Series No.

S343 S350L

For other products including modified standard & custom specials

Visit http://www.veederline.com.au email sales@veederline.com.au or call toll-free +61 8 8347 3711

Thank you.

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

BI-DIRECTIONAL CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

2 OF12

SEVENTEEN MODELS IN ORDER OF CURRENT RANGE

SERIES

905B XData Sheet

SERIES

S661B XData Sheet

SERIES

926 XData Sheet

SERIES

S764 XData Sheet

SERIES

S273 XData Sheet

MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; RESPONSE 50m-SEC; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS.

0 TO ±100MA 0 TO ±200MA 0 TO ±250MA 0 TO ±300MA

MIL GRADE: OUTPUT 0 TO ±5V; ACCURACY 0.25%FS; POWER +24 TO 32VDC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; RESPONSE 5m-SEC; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO ±5A 0 TO ±10A 0 TO ±15A

INDUSTRIAL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER +12 TO 36VDC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; RESPONSE 1m-SEC; PLASTIC CASE; BARRIER SCREW TERMINATIONS

MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

SPACE FLIGHT; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC;

S449

FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –40° TO +71°C; APERTURE 1/4 INCH DIA; SOLDER HEADER TERMINATIONS

SERIES

S745 XData Sheet

SERIES

929 XData Sheet

SERIES

S651 XData Sheet

SPACE FLIGHT; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±12VDC; FREQUENCY DC-20KHZ; RESPONSE 1-2µ-SEC; TEMPERATURE –55° TO +100°C; APERTURE 3/8 INCH DIA; METAL CASE; WEIGHT 8OZ.; SOLDER HEADER TERMINATIONS

MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS (OVER TEMPERATURE); POWER +10VDC TO +34VDC; FREQUENCY DC-350KHZ; RESPONSE 1µSEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; CONNECTOR OR BARRIER TERMINATIONS

MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER +22 TO

+32VDC; FREQUENCY DC-3.5KHZ; RESPONSE 100µ-SEC; TEMPERATURE –40° TO +65°C; APERTURE 1+3/8 INCH DIA; CONNECTOR TERMINATIONS

0 TO ±1A 0 TO ±2A 0 TO ±5A

CURRENT RANGES 0 TO ±400MA 0 TO ±500MA 0 TO ±750MA 0 TO ±1A

MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; FREQUENCY DC TO 60HZ; RESPONSE 1m-SEC; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

SERIES

XData Sheet

CURRENT RANGES

0 TO ±50MA 0 TO ±100MA 0 TO ±200MA 0 TO ±500MA

CURRENT RANGES 0 TO ±20A 0 TO ±25A

CURRENT RANGES 0 TO ±50A 0 TO ±60A 0 TO ±70A 0 TO ±100A

0 TO ±20A 0 TO ±25A 0 TO ±30A 0 TO ±40A

CURRENT RANGES 0 TO ±200A 0 TO ±250A 0 TO ±300A 0 TO ±350A

0 TO ±25A 0 TO ±50A 0 TO ±100A 0 TO ±150A

CURRENT RANGES 0 TO ±50A 0 TO ±60A

0 TO ±25A 0 TO ±40A

CURRENT RANGES 0 TO ±150A 0 TO ±250A

0 TO ±40A 0 TO ±75A

CURRENT RANGES 0 TO ±200A 0 TO ±250A 0 TO ±300A 0 TO ±400A

0 TO ±50A 0 TO ±75A 0 TO ±100A 0 TO ±150A

CURRENT RANGES 0 TO ±200A

0 TO ±100A

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

BI-DIRECTIONAL CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

3 of 12

CONTINUED (PART TWO OF TWO)

SERIES

S784 XData Sheet

SERIES

947 XData Sheet

SERIES

943A XData Sheet

AIRCRAFT DO-160; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER +16 TO 40VDC; FREQUENCY DC-1KHZ; RESPONSE 500µ-SEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; WEIGHT 9OZ.; SOLDER HEADER TERMINATIONS

INDUSTRIAL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER

±15VDC; FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –20° TO +70°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 1+3/8 INCH DIA; METAL CASE; BARRIER OR CONNECTOR TERMINATIONS

CURRENT RANGES 0 TO ±400A 0 TO ±500A 0 TO ±600A 0 TO ±750A

0 TO ±100A 0 TO ±200A 0 TO ±250A 0 TO ±300A

CURRENT RANGES 0 TO ±400A 0 TO ±500A 0 TO ±600A

0 TO ±100A 0 TO ±200A 0 TO ±300A

CURRENT RANGES 0 TO ±600A 0 TO ±750A 0 TO ±800A 0 TO ±1000A

0 TO ±100A 0 TO ±200A 0 TO ±300A 0 TO ±400A 0 TO ±500A

MIL GRADE: OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-20KHZ; TEMPERATURE –55° TO +85°C; APERTURE 1+3/8 INCH DIA; METAL CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS

0 TO ±600A 0 TO ±800A 0 TO ±1000A

XData Sheet

INDUSTRIAL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-20KHZ; TEMPERATURE –20° TO +70°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO ±600A 0 TO ±800A 0 TO ±1000A

SERIES

CLAMP-ON; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC;

SERIES

944 XData Sheet

SERIES

948

909M4 XData Sheet

RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; METAL CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS

SERIES

CLAMP-ON; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC;

9000

RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS

XData Sheet

SERIES

S630 XData Sheet

RAIL TRANSIT; OUTPUT 0 TO ±250MA; ACCURACY 0.5%FS; POWER +24VDC; RESPONSE 1M-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BUS-BAR AVAILABLE; BARRIER SCREW TERMINATIONS

CURRENT RANGES 0 TO ±1500A 0 TO ±2000A

CURRENT RANGES 0 TO ±1500A 0 TO ±2000A

CURRENT RANGES 0 TO ±1000A 0 TO ±1500A 0 TO ±2000A 0 TO ±2500A

0 TO ±150A 0 TO ±250A 0 TO ±500A 0 TO ±750A

CURRENT RANGES 0 TO ±1000A 0 TO ±1500A 0 TO ±2000A 0 TO ±2500A

0 TO ±150A 0 TO ±250A 0 TO ±500A 0 TO ±750A

CURRENT RANGE 0 TO ±1000A OUTPUT TO INPUT RATIO:

±250µA PER AMP

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

DC CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

4 of 12

NINETEEN MODELS IN ORDER OF CURRENT RANGE

SERIES

904B XData Sheet

SERIES

903B XData Sheet

SERIES

S767 XData Sheet

SERIES

936 XData Sheet

SERIES

S218 XData Sheet

SERIES

S619 XData Sheet

SERIES

950 XData Sheet

SERIES

913B XData Sheet

SERIES

913A XData Sheet

MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; TEMPERATURE –55° TO +85°C; INPUT VIA IN-LINE CONNECTION; RESPONSE 50m-SEC; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 50m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO +5MA 0 TO +10MA 0 TO +20MA 0 TO +50MA

DC CURRENT RANGES 0 TO +100MA 0 TO +200MA 0 TO +500MA

DC CURRENT RANGES 0 TO +200MA 0 TO +250MA 0 TO +500MA

GROUND FAULT OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 50m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 1+1/4 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 1m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO +1A 0 TO +2A 0 TO +5A

DC CURRENT RANGES 0 TO +1A 0 TO +2A 0 TO +5A

0 TO +100MA 0 TO +200MA 0 TO +500MA

SPACE FLIGHT; OUTPUT 0 TO +3.5V (ISOLATED); ACCURACY 2%FS; POWER +4.5 TO +5.5VDC; INPUT CURRENT BY IN-LINE CONNECTION; RESPONSE 1m-SEC; TEMPERATURE –55° TO +85°C; PCB MOUNT; SOLDER TERMINATIONS

MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 1m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO +1A 0 TO +2A 0 TO +5A

0 TO +10MA 0 TO +20MA 0 TO +50MA 0 TO +100MA

0 TO +10MA 0 TO +20MA 0 TO +50MA 0 TO +100MA

MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 0.5%FS; POWER +24 TO 32VDC; RESPONSE 10m-SEC; TEMPERATURE –25° TO +85°C; APERTURE 3/8 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO +1MA 0 TO +2MA 0 TO +5MA

DC CURRENT RANGES 0 TO +200MA 0 TO +250MA 0 TO +500MA 0 TO +1A

SPACE FLIGHT; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +22 TO 36VDC; RESPONSE 50m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 1/2 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

HV GROUND FAULT; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 100m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

DC CURRENT RANGES

0 TO +100µA 0 TO +200µA 0 TO +500µA

DC CURRENT RANGES 0 TO +10A

0 TO +3.5A

DC CURRENT RANGES 0 TO +40A 0 TO +50A

0 TO +10A 0 TO +20A 0 TO +30A

DC CURRENT RANGES 0 TO +30A 0 TO +50A 0 TO +35A 0 TO +75A 0 TO +40A 0 TO +100A

0 TO +10A 0 TO +15A 0 TO +20A 0 TO +25A

DC CURRENT RANGES 0 TO +40A 0 TO +50A 0 TO +75A 0 TO +100A

0 TO +10A 0 TO +20A 0 TO +25A 0 TO +30A

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

DC CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

5 of 12

CONTINUED (PART TWO OF TWO)

SERIES

S770 XData Sheet

SERIES

920 XData Sheet

SERIES

DCT XData Sheet

SERIES

S728B XData Sheet

SERIES

952 XData Sheet

INDUSTRIAL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +12 TO 36VDC; RESPONSE 1m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; CHASSIS MOUNT; BARRIER SCREW TERMINATIONS

DC CURRENT RANGES 0 TO +60A 0 TO +70A 0 TO +100A

0 TO +20A 0 TO +25A 0 TO +30A 0 TO + 50A

CLAMP-ON; OUTPUT 4 TO +20mADC; ACCURACY 1%FS; LOOP POWER +18 TO 28VDC; RESPONSE 10m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 1.60 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO +50A 0 TO +75A

CLAMP-ON; OUTPUT 0 TO +5V OR 4 TO 20MA; ACCURACY 1%FS; POWER +20 TO 50VDC OR 22 TO 38VAC; RESPONSE 100m-SEC; OPENING 0.85 X 0.85 INCH; TEMPERATURE –20° TO +50°C; PLASTIC CASE; BARRIER SCREW TERMINATIONS

-100: 0 TO +50A, 75A OR 100A -200: 0 TO +100A, 150A OR 200A -300: 0 TO +150A, 225A OR 300A -400: 0 TO +200A, 300A OR 400A

SPACE FLIGHT; OUTPUT 0 TO +5V; ACCURACY 0.3% TO 0.5%FS; POWER

+24 TO 32VDC; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 1/2 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER HEADER TERMINATIONS

MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 0.3% TO 0.5%FS; POWER +24 TO 32VDC; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER HEADER TERMINATIONS

DC CURRENT RANGES 0 TO +100A 0 TO +125A

DC CURRENT RANGES

DC CURRENT RANGES 0 TO +250A 0 TO +300A 0 TO +400A

0 TO +50A 0 TO +100A 0 TO +150A 0 TO +200A

0 TO +50A 0 TO +100A 0 TO +150A 0 TO +200A

DC CURRENT RANGES 0 TO +250A 0 TO +500A 0 TO +300A 0 TO +600A 0 TO +400A 0 TO +750A

CONNECTOR TERMINATIONS

0 TO +100A 0 TO +150A 0 TO +200A 0 TO +250A

DC CURRENT RANGES 0 TO +300A 0 TO +1500A 0 TO +500A 0 TO +2000A 0 TO +750A 0 TO +2500A 0 TO +1000A 0 TO +5000A

XData Sheet

CLAMP-ON; OUTPUT 4 TO +20mADC; ACCURACY 1%FS; LOOP POWER +18 TO 28VDC; RESPONSE 10m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 1.60 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO +200A 0 TO +250A 0 TO +300A

DC CURRENT RANGES 0 TO +400A 0 TO +1000A 0 TO +500A 0 TO +1500A 0 TO +750A 0 TO +2000A

SERIES

CLAMP-ON; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO

SERIES

S347 XData Sheet

SERIES

921

S444 XData Sheet

SERIES

S465 XData Sheet

CLAMP-ON; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO

32VDC; RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; METAL CASE; BARRIER SCREW OR

32VDC; RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS

0 TO +200A 0 TO +225A 0 TO +250A 0 TO +300A

RAIL TRANSIT CLAMP-ON; OUTPUT 4 TO 20MA; ACCURACY 1%FS; POWER

+16 TO 26VDC; RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS

SERIES

RAIL TRANSIT CLAMP-ON; OUTPUT 0 TO +6V; ACCURACY 2%FS; POWER

S646

+15VDC; RESPONSE 200µ-SEC; TEMPERATURE –30° TO +60°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

XData Sheet

DC CURRENT RANGES 0 TO +500A 0 TO +1500A 0 TO +750A 0 TO +2000A 0 TO +1000A 0 TO +2500A

DC CURRENT RANGES 0 TO +1000A 0 TO +1500A 0 TO +2000A 0 TO +2500A

0 TO +150A 0 TO +250A 0 TO +500A 0 TO +750A

DC CURRENT RANGES 0 TO +1000A

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

DC CURRENT DETECTORS

DATA SHEETS AT

www.a-a-c.com

PAGE

6 of 12

EIGHT MODELS IN ORDER OF CURRENT RANGE

SERIES

901B XData Sheet

SERIES

S204 XData Sheet

SERIES

S58 XData Sheet

SERIES

S754 XData Sheet

SERIES

S201 XData Sheet

SERIES

S680 XData Sheet

SERIES

S629 XData Sheet

SERIES

S623 XData Sheet

DC CURRENT RANGES 0 TO +500MA 0 TO +1A 0 TO +2A 0 TO +5A

GROUND FAULT; OUTPUT SOLID-STATE-SWITCH AND 0 TO 5VDC; ACCURACY 1%FS; POWER +21 TO +27VDC; RESPONSE 50M-SEC; TEMPERATURE –20° TO +70°C; APERTURE 3/4 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO +20MA 0 TO +50MA 0 TO +100MA 0 TO + 250MA

INDUSTRIAL GRADE; OUTPUT SPDT RELAY; ACCURACY 4% OF SET POINT; POWER +22.8 TO +30.4VDC; RESPONSE 3M-SEC; TEMP. –20° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO +100MA 0 TO +150MA 0 TO +350MA 0 TO +550MA

DC CURRENT RANGES 0 TO +1.2A 0 TO +2A 0 TO +3A 0 TO +5.75A

INDUSTRIAL GRADE; OUTPUT SOLID-STATE-SWITCH; AUTOMATIC RESET; POWER +22.8 TO +30.4VDC; RESPONSE 1M-SEC; TEMPERATURE 0° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

DC CURRENT RANGES 0 TO +15ADC

RAIL TRANSIT; OUTPUT SOLID-STATE-RELAY; PUSHBUTTON RESET; RESPONSE 100M-SEC; POWER +25 TO +45VDC; TEMPERATURE -40° TO +50°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

DC CURRENT RANGES 0 TO +20ADC

SWITCH TRIPS @ 60MADC ±20%

ADJUSTABLE TRIP CURRENT 500MA TO 1ADC

AIRCRAFT DO-160; OUTPUT SPST RELAY; AUTOMATIC RESET; POWER +24 TO +32VDC; RESPONSE 200M-SEC; TEMP. –55° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; CONNECTOR TERMINATIONS; DO-160 ENVIRONMENTAL REQUIREMENTS

DC CURRENT RANGES 0 TO +100ADC

RAIL TRANSIT; OUTPUT SOLID-STATE-RELAY; AUTOMATIC RESET; POWER +25 TO +45VDC; RESPONSE 1M-SEC; TEMPERATURE -25° TO +75°C; APERTURE 1+1/2 INCH DIA; AVAILABLE WITH BUS-BAR; PLASTIC CASE; BARRIER SCREW TERMINATIONS

DC CURRENT RANGES

RAIL TRANSIT; OUTPUT SPST RELAY (10A CONTACTS); AUTOMATIC RESET; RESPONSE 50M-SEC; TEMP –25° TO +75°C; POWER +25 TO +45VDC; APERTURE 1+1/2 INCH DIA; BUS-BAR AVAILABLE; PLASTIC CASE; BARRIER SCREW TERMINATIONS

DC CURRENT RANGES

RAIL TRANSIT GROUND FAULT; OUTPUT SPST RELAY; AUTOMATIC RESET; RESPONSE 50M-SEC; POWER +25 TO +45VDC; TEMP –25° TO +75°C; APERTURE 1+1/2 INCH DIA; DUAL BUS-BAR AVAILABLE; PLASTIC CASE; BARRIER SCREW TERMINATIONS

DC CURRENT RANGES

RELAY TRIPS@ +1ADC ±15%

0 to +1000Adc RELAY TRIPS@

±3Adc ±10%

0 to +1000Adc RELAY TRIPS@ ±45Adc ±0.5Adc

0 to +1600Adc RELAY TRIP ADJUSTMENT RANGE:

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

AC CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

7 OF 12

TWENTY-ONE MODELS IN ORDER OF CURRENT RANGE

SERIES

1055L XData Sheet

SERIES

S383L XData Sheet

SERIES

1002M1 XData Sheet

SERIES

S402 XData Sheet

SERIES

C XData Sheet

SERIES

CX XData Sheet

SERIES

1003AM1 XData Sheet

SERIES

1004 XData Sheet

SERIES

1005 XData Sheet

SERIES

1055 XData Sheet

INDUSTRIAL GRADE; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100mSEC; TEMP. –20° TO +85°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 50MA 0 TO 100MA 0 TO 200MA

PROCESS CONTROL; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100mSEC; TEMP. –40° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 50MA 0 TO 100MA 0 TO 200MA

AC CURRENT RANGES 0 TO 250MA 0 TO 500MA 0 TO 1A

AC CURRENT RANGES 0 TO 250MA 0 TO 500MA 0 TO 1A

MIL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; POWER +24 TO +32VDC; FREQUENCY 375-475HZ (OTHERS AVAILABLE); RESPONSE 10m-SEC; TEMPERATURE -55° TO +85°C; APERTURE 3/4 INCH DIA; SOLDER, CONNECTOR OR BARRIER SCREW TERMINATIONS

0 TO 250MA 0 TO 500MA 0 TO 1A 0 TO 5A 0 TO 10A

RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; POWER +24 TO +32VDC; FREQUENCY 57-63HZ (OTHERS AVAILABLE); RESPONSE 100m-SEC; TEMPERATURE 0° TO 70°C; APERTURE 3/4 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINALS

0 TO 250MA 0 TO 500MA 0 TO 1A 0 TO 2A 0 TO 3A

AC CURRENT RANGES 0 TO 20A 0 0 TO 25A 0 0 TO 50A 0 0 TO 65A 0

TO 100A TO 150A TO 200A TO 250A

AC CURRENT RANGES 0 TO 5A 0 0 TO 10A 0 0 TO 20A 0 0 TO 50A 0

TO 100A TO 150A TO 200A TO 250A

AVERAGE RESPONDING; OUTPUT 0 TO 1mADC; ACCURACY 0.25%FS; POWERED BY INPUT; FREQUENCY 47-1000HZ; RESPONSE 400m-SEC; TEMPERATURE -20° TO +70°C; INPUT BY IN-LINE CONNECTION; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 1A 0 TO 2A 0 TO 5A

AVERAGE RESPONDING; OUTPUT 4 TO 20MADC; ACCURACY 0.25%FS; LOOPPOWER 10 TO 35VDC; FREQUENCY 47-1000HZ; RESPONSE 400M-SEC; TEMPERATURE -20° TO +70°C; INPUT BY IN-LINE CONNECTION; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 1A 0 TO 2A 0 TO 5A

PROCESS OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY 5763HZ (OTHERS AVAILABLE); POWERED BY INPUT; RESPONSE 150m SEC; TEMPERATURE -20° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; BARRIER TERMINALS

AC CURRENT RANGES 0 TO 20A 0 0 TO 25A 0 0 TO 30A 0 0 TO 40A 0

TO 50A TO 60A TO 75A TO 100A

0 TO 2A 0 TO 5A 0 TO 7A 0 TO 10A 0 TO 15A

AC CURRENT RANGES 0 TO 10A 0 TO 20A

AC CURRENT RANGES 0 TO 10A 0 TO 20A

MIL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY 375 TO 475HZ; RESPONSE 150m-SEC; TEMPERATURE -55° TO +85°C; POWERED BY INPUT; APERTURE 3/8 OR 3/4 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINATIONS

0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A

AC CURRENT RANGES 0 TO 50A 0 0 TO 100A 0 0 TO 150A 0 0 TO 200A 0

TO 250A TO 300A TO 350A TO 400A

INDUSTRIAL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 1-2%FS; FREQUENCY 50 TO 60HZ; RESPONSE 80m-SEC; TEMPERATURE -20° TO +70°C; POWERED BY INPUT; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A

AC CURRENT RANGES 0 TO 30A 0 0 TO 50A 0 0 TO 75A 0 0 TO 100A 0

TO 150A TO 200A TO 250A TO 300A

AC CURRENT RANGES 0 TO 30A 0 0 TO 40A 0 0 TO 50A 0 0 TO 75A 0

TO 100A TO 150A TO 200A TO 250A

INDUSTRIAL GRADE; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100m-SEC; TEMPERATURE –20° TO +85°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A 0 TO 25A

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

AC CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

8 OF 12

CONTINUED (PART TWO OF THREE)

SERIES

S383 XData Sheet

SERIES

1070 XData Sheet

SERIES

ACTS XData Sheet

SERIES

ACT XData Sheet

SERIES

1006 XData Sheet

SERIES

1006X XData Sheet

SERIES

S714 XData Sheet

SERIES

S786 XData Sheet

SERIES

1003AM2 XData Sheet

SERIES

1001 XData Sheet

PROCESS CONTROL; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS AC RMS; OUTPUT 4 TO 20mA; ACCURACY 0.25%FS; TWO WIRE LOOP POWER +12 TO +32VDC; FREQUENCY 20-2KHZ; RESPONSE 300m-SEC; TEMP –40° TO +85°C; APERTURE 3/4 INCH; PLASTIC CASE; BARRIER SCREW, CONNECTOR OR SUB-D TERMINATIONS

0 TO 2A 0 TO 5A 0 TO 10A 0 TO 15A

AC RMS CLAMP-ON; OUTPUT 4 TO 20mA; ACCURACY 0.8%FS; LOOP POWER +24 TO +40VDC; FREQUENCY 10-400HZ; RESPONSE 600mSEC; TEMPERATURE –20° TO +50°C; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS AC-AVG RESPONDING CLAMP-ON; OUTPUT 0 TO 5VDC, 0 TO 10VDC OR 4 TO 20mA; ACCURACY 0.5% OR 1%FS; SELF OR LOOP POWER; FREQUENCY 50-60HZ OR 20-100HZ; TEMPERATURE –20° TO +50°C; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS INDUSTRIAL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; FREQUENCY 50 TO 60HZ; RESPONSE 130m-SEC; TEMPERATURE -20° TO +70°C; POWERED BY INPUT; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

AC CURRENT RANGES 0 TO 30A 0 0 TO 40A 0 0 TO 50A 0 0 TO 75A 0

0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A

AC CURRENT RANGES 0 TO 50A 0 TO 75A 0 TO 100A 0 TO 150A

0 TO 20A 0 TO 25A 0 TO 30A 0 TO 40A

TO 100A TO 150A TO 200A TO 250A

0 TO 200A 0 TO 250A

AC CURRENT RANGES

-05: -50: -200:

0 TO 2A, OR 5A 0 TO 10A, 20A OR 50A 0 TO 100A, 150A OR 200A

AC CURRENT RANGES

-05: -50: -200:

0 TO 5A 0 TO 10A 0 TO 25A 0 TO 30A 0 TO 50A

0 TO 2A, OR 5A 0 TO 10A, 20A OR 50A 0 TO 100A, 150A OR 200A AC CURRENT RANGES 0 TO 75A 0 0 TO 100A 0 0 TO 150A 0 0 TO 250A 0 0 TO 400A

TO 500A TO 600A TO 800A TO1000A

0 TO 5A 0 TO 10A 0 TO 25A 0 TO 50A 0 TO 75A

AC CURRENT RANGES 0 TO 100A 0 TO 500A 0 TO 150A 0 TO 800A 0 TO 200A 0 TO 1000A 0 TO 300A 0 TO 1200A 0 TO 400A

0 TO 5A 0 TO 10A 0 TO 25A 0 TO 50A

AC CURRENT RANGES 0 TO 75A 0 TO 300A 0 TO 100A 0 TO 400A 0 TO 150A 0 TO 500A 0 TO 200A 0 TO 600A

RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; FREQUENCY 60HZ; POWER +14 TO +32VDC; RESPONSE 75m-SEC; TEMPERATURE -40° TO +85°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 5A 0 TO 10A 0 TO 20A 0 TO 25A 0 TO 50A

AC CURRENT RANGES 0 TO 75A 0 TO 400A 0 TO 100A 0 TO 500A 0 TO 150A 0 TO 600A 0 TO 200A 0 TO 800A 0 TO 300A 0 TO 1000A

AVG RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY 57-63HZ (OTHERS AVAILABLE); POWERED BY INPUT; RESPONSE 150mSEC; TEMPERATURE -20° TO +70°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 10A 0 TO 15A 0 TO 20A 0 TO 25A 0 TO 30A

INDUSTRIAL GRADE; OUTPUT 4 TO 20mADC; ACCURACY 0.5%FS; FREQUENCY 50 TO 60HZ; LOOP POWER +5 TO +35VDC; RESPONSE 100m-SEC; TEMPERATURE -20° TO +70°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; FREQ. 360 TO 440HZ; POWER +14 TO +32VDC; RESPONSE 75m-SEC; TEMPERATURE -40° TO +85°C; APERTURE 1+3/8 INCH DIA; METAL CASE; CONNECTOR OR BARRIER SCREW TERMINATIONS

CLAMP-ON RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY DC TO 480HZ; POWER +24 TO +32VDC; RESPONSE 100m-SEC; TEMPERATURE -25° TO +75°C; APERTURE 1+1/2 INCH DIA; METAL CASE; CONNECTOR OR BARRIER SCREW TERMINATIONS

0 TO 100A 0 TO 150A 0 TO 250A 0 TO 500A

AC CURRENT RANGES 0 TO 50A 0 TO 150A 0 TO 75A 0 TO 200A 0 TO 100A 0 TO 250A 0 TO 125A 0 TO 300A

AC CURRENT RANGES 0 TO 750A 0 TO 2000A 0 TO 1000A 0 TO 2500A 0 TO 1500A 0 TO 3000A

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

AC CURRENT TRANSDUCERS

DATA SHEETS AT

www.a-a-c.com

PAGE

9 OF 12

CONTINUED (PART THREE OF THREE)

SERIES

S461 XData Sheet

CLAMP-ON RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY DC TO 480HZ; POWER +24 TO +32VDC; RESPONSE 100m-SEC; TEMPERATURE -25° TO +71°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; CONNECTOR OR BARRIER SCREW TERMINALS

0 TO 100A 0 TO 150A 0 TO 250A 0 TO 500A

AC CURRENT RANGES 0 TO 750A 0 TO 2000A 0 TO 1000A 0 TO 2500A 0 TO 1500A 0 TO 3000A

AC CURRENT DETECTORS

DATA SHEETS AT

www.a-a-c.com

NINE MODELS IN ORDER OF CURRENT RANGE

SERIES

870 XData Sheet

SERIES

S871 XData Sheet

SERIES

882 XData Sheet

SERIES

ACS XData Sheet

SERIES

ACS-3 XData Sheet

SERIES

ACS-SC XData Sheet

SERIES

881 XData Sheet

SERIES

880B XData Sheet

HEAVY INDUSTRIAL; OUTPUT SPDT-RELAY (10A CONTACTS); AUTO RESET; ADJUSTABLE (20% TO 100%); POWER 115VAC; FREQUENCY 47-63HZ; TEMPERATURE –20° TO +71°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 1A 0 TO 2A 0 TO 5A 0 TO 10A

AC CURRENT RANGES 0 TO 15A 0 TO 150A 0 TO 20A 0 TO 200A 0 TO 50A 0 TO 250A 0 TO 100A 0 TO 300A

WIDE FREQUENCY; OUTPUT SPDT-RELAY (10A CONTACTS); AUTO RESET; ADJUSTABLE (20% TO 100%); POWER 115VAC; FREQUENCY 47-400HZ; TEMPERATURE –20° TO +71°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 1A 0 TO 2A 0 TO 5A 0 TO 10A

AC CURRENT RANGES 0 TO 15A 0 TO 150A 0 TO 20A 0 TO 200A 0 TO 50A 0 TO 250A 0 TO 100A 0 TO 300A

CURRENT CONTROLLER: OUTPUT SPDT RELAY (2A CONTACTS); AUTO RESET; ADJUSTABLE (20% TO 100%); POWER 115VAC; FREQUENCY 50-400HZ; TEMPERATURE –20° TO +71°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 1A 0 TO 2A 0 TO 5A 0 TO 10A

AC CURRENT RANGES 0 TO 15A 0 TO 150A 0 TO 20A 0 TO 200A 0 TO 50A 0 TO 250A 0 TO 100A 0 TO 300A

CLAMP-ON SWITCH; OUTPUT SOLID STATE SWITCH; ADJUSTABLE OR FIXED; FREQUENCY 6-100HZ; RESPONSE 120m-SEC; TEMPERATURE -50° TO +65°C; POWERED BY INPUT; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 250MA 0 TO 500MA 0 TO 1A 0 TO 2A

AC CURRENT RANGES 0 TO 5A 0 0 TO 10A 0 0 TO 20A 0 0 TO 50A 0

CLAMP-ON SWITCH; OUTPUT SOLID STATE SWITCH; RANGE SELECTABLE; FREQUENCY 6-100HZ; RESPONSE 120m-SEC; TEMPERATURE -50° TO +65°C; POWERED BY INPUT; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS

CLAMP-ON SWITCH; OUTPUT SOLID STATE SWITCH; POWERED BY INPUT; FREQUENCY 6-100HZ; RESPONSE 200m-SEC; TEMPERATURE -50° TO +65°C; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS

1.5 TO 6A,

TO 100A TO 150A TO 200A TO 250A

AC CURRENT RANGES 6 TO 40A OR 40 TO 200A

SWITCH AVAILABLE NORMALLY OPEN OR NORMALLY CLOSED

0 TO 1A 0 TO 2A 0 TO 5A

AC CURRENT RANGES 0 TO 10A 0 TO 20A

AC CURRENT RANGES

INDUSTRIAL GRADE; OUTPUT SPDT-RELAY (2A CONTACTS); AUTOMATIC RESET; ADJUSTABLE TRIP POINT; POWER 115VAC; FREQUENCY 50400HZ; TEMPERATURE –20° TO +70°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 12A ............. (TRIP ADJ 2-12A) 0 TO 50A ............. (TRIP ADJ 8-50A) 0 TO 120A ........... (TRIP ADJ 40-120A) 0 TO 250A ........... (TRIP ADJ 100-250A)

INDUSTRIAL GRADE; OUTPUT SOLID STATE SWITCH; AUTOMATIC RESET; POWERED BY INPUT; ADJUSTABLE TRIP POINT; FREQUENCY 50-400HZ; TEMPERATURE –20° TO +70°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS

0 TO 12A ............. (TRIP ADJ 2-12A) 0 TO 50A ............. (TRIP ADJ 8-50A) 0 TO 120A ........... (TRIP ADJ 40-120A) 0 TO 250A ........... (TRIP ADJ 100-250A)

AC CURRENT RANGES

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

AC CURRENT DETECTORS

DATA SHEETS AT

www.a-a-c.com

PAGE

10 OF 12

CONTINUED (PART THREE OF THREE) SERIES

S212 XData Sheet

DATA SHEETS AT

AIRCRAFT DO-160; OUTPUT SPDT-RELAY; AUTOMATIC RESET; POWER +24 TO +32VDC; RESPONSE 200M-SEC; TEMPERATURE –55° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; CONNECTOR TERMINATIONS; DO-160 ENVIRONMENTAL REQUIREMENTS

AC CURRENT RANGES

0 TO 75A (360-440HZ) RELAY TRIPS @ 0.5AAC ±0.75AAC

AC VOLTAGE TRANSDUCERS

www.a-a-c.com

EIGHT MODELS IN ORDER OF VOLTAGE RANGE

SERIES

108 XData Sheet

SERIES

108X XData Sheet

SERIES

S190 XData Sheet

SERIES

V XData Sheet

SERIES

VX XData Sheet

SERIES

101M3 XData Sheet

SERIES

102M3 XData Sheet

SERIES

105 XData Sheet

INDUSTRIAL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; RESPONSE 300mSEC; POWERED BY INPUT; FREQUENCY 57-63HZ (400HZ AVAILABLE); TEMPERATURE –20° TO +70°C; METAL CASE; BARRIER SCREW TERMINALS OR OPTIONAL CONNECTOR

AC VOLTAGE RANGES 0 TO 300V 0 TO 500V 0 TO 600V

0 TO 50V 0 TO 130V 0 TO 150V 0 TO 270V

AC VOLTAGE RANGES 0 TO 300V 0 TO 500V 0 TO 600V

PROCESS CONTROL; OUTPUT 4 TO 20mADC; ACCURACY 0.5%FS; RESPONSE 300m-SEC; LOOP POWER +10 TO +35VDC; FREQUENCY 57-63HZ (400HZ AVAILABLE); TEMPERATURE –20° TO +70°C; METAL CASE; BARRIER SCREW TERMINALS OR OPTIONAL CONNECTOR

0 TO 50V 0 TO 130V 0 TO 150V 0 TO 270V

INDUSTRIAL GRADE; OUTPUT 0 TO 10VDC; ACCURACY 2%FS; RESPONSE 200M-SEC; POWERED BY INPUT; FREQUENCY 47-63HZ (400HZ AVAILABLE); TEMPERATURE 0° TO +60°C; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 130V 0 TO 150V 0 TO 270V

AC VOLTAGE RANGES 0 TO 300V 0 TO 600V

UTILITY GRADE; OUTPUT 0 TO 1mADC; ACCURACY 0.25%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 47-1000HZ; TEMPERATURE – 20° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS

AC VOLTAGE RANGES 0 TO 150V 0 TO 300V 0 TO 500V

PROCESS CONTROL; OUTPUT 4 TO 20mADC; ACCURACY 0.5%FS; RESPONSE 400m-SEC; LOOP POWER +10 TO 32VDC; FREQUENCY 47-1000HZ; TEMPERATURE –20° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS

AC VOLTAGE RANGES 0 TO 150V 0 TO 300V 0 TO 500V

HIGH RESOLUTION; OUTPUT 0 TO 5VDC; ZERO SUPPRESSED INPUT RANGE; ACCURACY 0.5%FS; RESPONSE 1/2-CYCLE OF AC; POWERED BY INPUT; FREQUENCY 57-63HZ; TEMPERATURE -40° TO +70°C; METAL CASE; BARRIER SCREW TERMINALS

AC VOLTAGE RANGES 90 TO 150V

FAST RESPONSE; OUTPUT 0 TO 5VDC; POWERED BY INPUT; ACCURACY 0.5%FS; ZERO SUPPRESSED INPUT RANGE; RESPONSE 1-CYCLE OF AC; FREQUENCY 340-440HZ; TEMPERATURE -40° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS

AC VOLTAGE RANGES 90 TO 175V 105 TO 130V 175 TO 225V

ZERO SUPPRESSED INPUT RANGE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; RESPONSE 1-CYCLE OF AC; POWERED BY INPUT; FREQUENCY 57-63HZ; TEMPERATURE -40° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS

AC VOLTAGE RANGES 390 TO 490V 455 TO 505V 430 TO 530V

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

DATA SHEETS AT

DC VOLTAGE TRANSDUCER & DETECTOR

www.a-a-c.com

PAGE

11 OF 12

TWO MODELS IN ORDER OF VOLTAGE RANGE

SERIES

S657 XData Sheet

SERIES

S631 XData Sheet

RAIL TRANSIT GRADE; OUTPUT 4 TO 20MADC PROPORTIONAL TO (±) INPUT ABSOLUTE VALUE; ACCURACY 1%FS OVER TEMP; ISOLATION 5KV; RESPONSE 5M-SEC; POWER +22 TO +26VDC; TEMPERATURE –40° TO +85°C; PLASTIC CASE; CONNECTOR AND MATING CONNECTORS INCLUDED

DC VOLTAGE RANGES

0 TO ±150V 0 TO ±750V 0 TO ±300V 0 TO ±1200V 0 TO ±500V 0 TO ±1500V 0 TO ±2000V DC VOLTAGE RANGE 0 TO +800V

RAIL TRANSIT GRADE; OUTPUT SPST RELAY (10A CONTACTS); AUTOMATIC RESET @ +365VDC; ACCURACY 1%FS; RESPONSE 110m-SEC; POWER +25 TO +45VDC; TEMPERATURE –25° TO +75°C; PLASTIC CASE; BARRIER SCREW TERMINATIONS

DATA SHEETS AT

RELAY TRIPS @ +375VDC ±2VDC

AC POWER TRANSDUCERS

www.a-a-c.com

FIVE MODELS IN ORDER OF POWER RANGE

SERIES

W&Q XData Sheet

SERIES

S73 XData Sheet

SERIES

415A XData Sheet

SERIES

416A XData Sheet

SERIES

S217 XData Sheet

DATA SHEETS AT

UTILITY GRADE; 1φ AND 3φ WATT & VAR TRANSDUCERS; FREQUENCY 60HZ (50 & 400HZ AVAILABLE); OUTPUT 0 TO ±1mADC (±5V & ±10VDC AVAILABLE); ACCURACY 0.25%FS; RESPONSE 400m-SEC; POWERED BY INPUT; TEMPERATURE –20° TO +70°C

AC POWER RANGES

0 TO 6.5AAC AND 85 TO 140VAC 1φ (2-WIRE) ACCEPTS BALANCED 3φ (3-WIRE) OR UNRESTRICTED 3φ (4-WIRE) LOADS & VOLTAGE

BARRIER SCREW TERMINATIONS

0 TO 1KW 0 TO 2KW 0 TO 2.5KW 0 TO 5KW

AC POWER RANGES 0 TO 10KW 0 TO 40KW 0 TO 15KW 0 TO 50KW 0 TO 20KW 0 TO 60KW 0 TO 30KW 0 TO 100KW

80-150VAC OR 160-230VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 5763HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 1KW 0 TO 2KW 0 TO 2.5KW 0 TO 5KW

AC POWER RANGES 0 TO 10KW 0 TO 40KW 0 TO 15KW 0 TO 50KW 0 TO 20KW 0 TO 60KW 0 TO 30KW 0 TO 100KW

TERMINATIONS

0 TO 4KW 0 TO 10KW 0 TO 20KW

AC POWER RANGES 0 TO 40KW 0 TO 100KW 0 TO 50KW 0 TO 200KW 0 TO 80KW

160-300VAC & 320-480VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 5763HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS

0 TO 2-4KW 0 TO 5-10KW 0 TO 10-20KW

0-115VAC OR 0-230VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWER 120VAC; FREQUENCY 57-63HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE;

320-560VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 57-63HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW

AC POWER RANGES 0 TO 20-40KW 0 TO 25-50KW 0 TO 40-80KW

FREQUENCY TRANSDUCERS

www.a-a-c.com

TWO MODELS IN ORDER OF FREQUENCY RANGE SERIES

S350L XData Sheet

FLIGHT TEST; OUTPUT 0 TO 5VDC; LINEARITY 0.1%FS; INPUT VOLTAGES FROM 20MV TO 50V-RMS; RESPONSE =30/FREQUENCY; POWER +22 TO +30VDC; TEMPERATURE –48° TO +74°C; METAL CASE; CONNECTOR TERMINATIONS

100HZ 200HZ 300HZ 500HZ

FREQUENCY RANGES 1KHZ 5KHZ 2KHZ 10KHZ 3KHZ 20KHZ

FREQUENCY RANGES

SERIES

S343 XData Sheet

MIL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; RESPONSE 250M-SEC; POWERED BY INPUT; TEMPERATURE –40° TO +70°C; RANGE & ZERO ADJUSTMENTS; METAL CASE; CONNECTOR TERMINATIONS

360 TO 440HZ @ 102-127VAC 360 TO 440HZ @ 200-250VAC AVAILABLE FIELD ADJUSTMENTS RANGE (±3%) & ZERO (±3%)

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


CERTIFIED

ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS

SF CATALOG

705

Current Voltage Power & Frequency Transducers

PAGE

12 OF 12

5-YEAR WARRANTY: AAC warrants all the products in this catalog to be free from defects in material and workmanship. The warranty applies to the product or parts thereof returned to AAC, with transportation charges prepaid, within five years of the original date of delivery to the original purchaser. Our obligation is limited to servicing, adjusting or replacing, at AAC option, any product or part thereof. Returns to the factory must be authorized in advance. For products sold to a manufacturer that uses it within an assembly made for resale, the remaining warranty is transferable, providing the product is sold as original equipment. Since 1965 we have continued to strive toward higher levels of product performance, quality and service. AAC provides AC & DC current, voltage, power and frequency transducers for: Industrial automation; laboratory; rail transit; land vehicles; shipboard; aircraft, missile and space flight applications. Products in this catalog represent only part of a broad line of measurement and control instrumentation. In addition, there are numerous and diverse variations available for unique applications.

Quality, reliability and safety are designed in and carefully monitored throughout each process from order entry to shipment. Systems are based on IPC industry standard plus calibration and metrology traceable to NIST. Many of our products are UL, CSA and EU recognized and come with a FIVE YEAR WARRANTY. AAC is a woman owned small business certified to ISO 9001:2000 & AS9100:2004(B).

New and innovative products are continually being developed to meet customer requirements. Product designs focus on the user’s needs and our customers demand for competitive prices and quick delivery. This is the reason we offer a wide product selection from stock and continue to develop application specific modifications and custom products.

Maintaining a long cherished reputation for outstanding customer service is considered an important priority. Every attempt is made to satisfy any reasonable request. AAC computerized tracking schedule continuously monitors customer orders and provides immediate status upon request. An experienced staff stands ready to assist with product selections and to recommend alternative instrumentation solutions.

The fast delivery of cost effective products is due to: X State of the art CAD engineering from circuit analysis to mechanical design. Y Computerized inventory for quick access to parts and materials.

AAC American Aerospace Controls, Inc. 570 Smith Street, Farmingdale New York 11735-1115 USA

Z Up-to-date in house manufacturing including: coil winding, automated soldering, surface mount technology, encapsulation and more.

Telephone: (631) 694-5100 Toll Free: (888) 873-8559 Facsimile: (631) 694-6739

[ In house testing – random vibration, mechanical shock, thermal vacuum, high-energy pulse testing, high current and high voltage testing.

E-Mail: aac@rcn.com Website: http://www.a-a-c.com

AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT SENSOR SERIES 905B

PART NO.

INPUT CURRENT RANGE

905B-50 .......................0 TO ±50mA 905B-100 .....................0 TO ±100mA 905B-200 .....................0 TO ±200mA 905B-500 .....................0 TO ±500mA

INPUT CURRENT RANGE

PART NO.

905B-1 ..................................... 0 TO ±1A 905B-1.5 .................................. 0 TO ±1.5A 905B-2 ..................................... 0 TO ±2A 905B-5 ..................................... 0 TO ±5A

OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ± 5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RIPPLE .............................................................................. 2% FS RMS max. RESPONSE....................................................................... 50 m-sec. max. (10 to 90%) IMPEDANCE ..................................................................... 1000 Ohms ±5%, 5mA to 1A range 666 Ohms 1.5A range, 500 Ohms 2A range, 200 Ohms 5A range TEMPERATURE COEFFICIENT...................................... ±.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. ±50mAdc max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -55°C to +85°C STORAGE TEMPERATURE RANGE .............................. -55°C to +85°C INSULATION RESISTANCE ............................................ 100 M-ohms (A thru E to case) DIELECTRIC STRENGTH................................................ 350V RMS (A thru E to case) ALTITUDE ......................................................................... Operating sea level to 60,000 ft. VIBRATION ....................................................................... Operating 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK .............................................................................. Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE ............................................... Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Meets spec. for any mounting position RIPPLE .............................................................................. 40mV reflected onto pass-thru line WEIGHT ............................................................................ 1.25 lbs. max.

TERMINAL IDENTIFICATION A. B. C. D. E. F.

Code Ident. No. 15948

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+) CASE GROUND

AAC

Drawing Number

Rev.

700-905B

K

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES S661B CURRENT PART NUMBER RANGE S661B-100 ...........................0 to 100mA S661B-200 ...........................0 to 200mA S661B-250 ...........................0 to 250mA S661B-300 ...........................0 to 300mA

PART CURRENT NUMBER RANGE S661B-400 ......................... 0 to 400mA S661B-500 ......................... 0 to 500mA S661B-750 ......................... 0 to 750mA S661B-1A........................... 0 to 1A

INPUT POWER RANGE NOMINAL.................................................... OVERLOAD .............................................................. VOLTAGE ................................................................. FREQUENCY RANGE .............................................

See Table mAdc or Ac peak 0 to ±25 Adc 1000 Vrms DC to 60Hz

OUTPUT VOLTAGE SIGNAL................................................... ACCURACY ............................................................ TEMPERATURE COEFFICIENT ............................. OUTPUT IMPEDANCE ............................................ RESPONSE TIME (10 TO 90%) .............................. SHORT CIRCIUT ..................................................... RIPPLE .....................................................................

0 to ±5Vdc or Ac peak ±1% Full Scale ±0.02% FS/°C max. 250 Ohms max. 1 Msec. max. Protected 1% FS RMS

POWER SUPPLY SUPPLY VOLTAGE.................................................. ± 15Vdc (±0.5Vdc) CURRENT DRAIN.................................................... 50mA PROTECTION .......................................................... Reverse Polarity Protected

TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE(-) C. SUPPLY RTN D. OUTPUT RTN E. OUTPUT SIGNAL (+) F. CASE GROUND

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................ -40 to +85°C STORAGE TEMPERATURE ................................... -50 to +85 °C OPERATING HUMIDITY .......................................... 0 to 95% RH Operating MOISTURE RESISTANCE ...................................... Will meet method 106 of Mil-Std-202, Method 507.3 procedure 1 of Mil-Std-810. SALT FOG ................................................................ Mil-Std-202, Method 101, 5% salt solution FUNGUS................................................................... Mil-Std-810, Table 508.4 ALTITUDE................................................................. Operating Sea Level to 60,000 Ft. SHOCK ..................................................................... Operating 50g, 11 m-sec half sine pulse Method 213B condition A of Mil-std-202 VIBRATION............................................................... Operating 0.06 inch D.A. 10Hz to 55Hz Method 201A and Random Method 214A Test Condition 1 Level D, 3 Min. Per Axis, 11.95 Overall RMS G, Per Mil-Std-202. ATTITUDE ................................................................ Performs in any position WEIGHT ................................................................... 0.95 lbs. Max. ESD RATING............................................................ 2000V

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S661B-905

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT SENSOR SERIES 926

INPUT CURRENT MODEL NUMBER 926-5 .. .................................................. 0 TO ±5 926-10 .................................................. 0 TO ±10 926-15 .................................................. 0 TO ±15 926-20 .................................................. 0 TO ±20 926-25 .................................................. 0 TO ±25 INPUT CURRENT RANGE........................................................... Adc See Table CURRENT OVERLOAD.................................................... ±100Adc Nondestructive/Nonlatching/ Saturated Output OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ±5Vdc FS (Full Scale) ACCURACY....................................................................... ±0.25% FS (±12.5mV) OUTPUT IMPEDANCE ..................................................... 100 Ohms max. OUTPUT RIPPLE.............................................................. 0.2% FS RMS max. RESPONSE (10 TO 90%)................................................. 5 m-sec max. TEMPERATURE COEFFICIENT...................................... ±0.006% FS/°C max. OUTPUT PROTECTION .................................................. Short CKT continuously no damage OUTPUT ISOLATION ....................................................... Output/Supply & Case all isolated POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 85mAdc max. OVER VOLTAGE PROTECTION..................................... ±35Vdc without damage REVERSE POLARITY PROTECTION .............................10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -55° to +85°C STORAGE TEMPERATURE ............................................ -55° to +100°C OPERATING HUMIDITY................................................... 0% to 95% RH MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 ALTITUDE ......................................................................... Operating sea level to 60,000 ft. SHOCK .............................................................................. Operating - 50g, 11m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) VIBRATION ....................................................................... Operating - 0.06 inch D.A., 10 to 55Hz (Method 201 of MIL-STD-202) DIELECTRIC STRENGTH................................................ 350V RMS (Method 301 of MIL-STD-202) INSULATION RESISTANCE ............................................ 100-M-Ohms min. @ 500Vdc ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. WEIGHT ............................................................................ 1.25 lbs. Max.

TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT SIGNAL (RTN) D. SPARE E. OUTPUT SIGNAL (+) F. CASE GROUND

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-926

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES S764 PART CURRENT NUMBER RANGE S764-50…………………0 to ±50 S764-60…………………0 to ±60 S764-70…………………0 to ±70 S764-100………………. 0 to ±100

PART CURRENT NUMBER RANGE S764-20 .........................0 to ±20 S764-25 .........................0 to ±25 S764-30 .........................0 to ±30 S764-40…………………0 to ±40 INPUT RANGE .............................................................................. OVERLOAD CONTINUOUS............................................. FREQUENCY RANGE ......................................................

See Table Adc ±2000Adc DC to 350Hz

OUTPUT VOLTAGE SIGNAL ........................................................... ACCURACY....................................................................... RESPONSE (10 to 90%) ................................................... OUTPUT IMPEDANCE ..................................................... LOAD RESISTANCE ........................................................ TEMPERATURE COEFFICIENT...................................... OUTPUT PROTECTION ..................................................

0 to ±5Vdc FS ±1% FS 1 m sec. 10 Ohms 10k Ohms min ±.02%FS per °c max. Short Circuit

POWER SUPPLY SUPPLY VOLTAGE ......................................................... CURRENT DRAIN............................................................. PROTECTION................................................................... TRANSIENT PROTECTION.............................................

+12Vdc to +36Vdc 10mAdc max. Reverse polarity protected ±60V (T<5mS)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -40° to +85°C STORAGE TEMPERATURE RANGE .............................. -40° to +85°C ISOLATION ....................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE ............................................ 500 M-Ohms @ 500Vdc CASE MATERIAL.............................................................. Molded Plastic meets UL flammability rating 94V-O WEIGHT ........................................................................... 10 oz. Max.

TERMINAL IDENTIFICATION 1. 2.

3. 4.

SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+)

TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S764

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 BIDIRECTIONAL CURRENT SENSOR SERIES S273 TEMPERATURE PART NO.

INPUT CURRENT

ACCURACY

COEFFICIENT

S273-25 .......................0 to ±25A ...........................

1%................................. .08%

S273-50 .......................0 to ±50A ...........................

1%................................. .06%

S273-100 .....................0 to ±100A ......................... .5%................................. .04% S273-150 .....................0 to ±150A ......................... .5%................................. .02% S273-200 .....................0 to ±200A ......................... .5%................................. .02% S273-250 .....................0 to ±250A ......................... .5%................................. .02% S273-300 .....................0 to ±300A ......................... .5%................................. .02% S273-350 .....................0 to ±350A ......................... .5%................................. .02% OUTPUT VOLTAGE SIGNAL ........................................................... ACCURACY....................................................................... di/dt ACCURATELY FOLLOWED..................................... DELAY TIME ..................................................................... BANDWIDTH .................................................................... IMPEDANCE .....................................................................

0 to ±5Vdc FS (Full Scale) % FS See Table Better than 50A/u-sec. Better than 1u-sec. DC to 100KHz 500 Ohms (25A) 200 Ohms max. (50 -350A) FS/°C max. See Table

TEMPERATURE COEFFICIENT...................................... POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. 100mAdc max. REVERSE POLARITY PROTECTION ............................. 10µA max. current drain no damage. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -55° to +85°C STORAGE TEMPERATURE ............................................ -55° to +85°C OPERATING HUMIDITY................................................... 0% to 95% RH MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Procedure I of MIL-STD-810 ALTITUDE ......................................................................... Operating: Sea level to 60,000 ft. Non-operating: Sea level to 120,000 ft. (Method 105, Condition A of MIL-STD-202) SHOCK .............................................................................. Non-operating: 50g, 11m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) VIBRATION ....................................................................... Non-operating: 0.06 in. D.A., 10 to 55Hz (Method 201 of MIL-STD-202) DIELECTRIC STRENGTH................................................ 350V RMS dielectric withstanding voltage (Method 301 of MIL-STD-202) INSULATION RESISTANCE ............................................ 10M-Ohms min. (Method 302, Condition A of MIL-STD-202) ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. WEIGHT ........................................................................... 14 oz. max. TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (-) C. SUPPLY VOLTAGE (RTN) D. OUTPUT SIGNAL (RTN) E. OUTPUT SIGNAL (+) F. CASE GROUND

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-S273-925

K

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 BIDIRECTIONAL CURRENT TRANSDUCER SERIES S449

TEMPERATURE PART NO.

INPUT CURRENT

ACCURACY

COEFFICIENT

S449-25 .........................0 to ±25................................ ±1.0% ............................ ±0.05% S449-40 .........................0 to ±40................................ ±0.5% ............................ ±0.03% S449-50 .........................0 to ±50................................ ±0.5% ............................ ±0.025% S449-60 .........................0 to ±60................................ ±0.5% ............................ ±0.025% INPUT CURRENT RANGE................................................................... FREQUENCY RANGE .............................................................. CURRENT OVERLOAD............................................................

Adc or ac peak See Table DC to 2KHz continuous operation Unlimited (Nondestructive Nonlatching/ Saturated Output)

OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... OUTPUT IMPEDANCE ............................................................. RESPONSE (10 to 90%) ........................................................... BANDWIDTH ............................................................................ TEMPERATURE COEFFICIENT.............................................. OUTPUT NOISE ....................................................................... LINEAR OVER RANGE ............................................................

0 to ±5.0Vdc FS (Full Scale) See Table 400 Ohms max. 1u-sec max. DC to 100KHz FS/°C max. See Table 10mV RMS max. 10% above FS

POWER SUPPLY SUPPLY VOLTAGE ................................................................. CURRENT DRAIN..................................................................... MAX. OVER VOLTAGE ............................................................ REVERSE POLARITY ..............................................................

±15Vdc ±250mV ±40mA max. ±17Vdc continuous (Nondestructive) 10µA drain (Nondestructive)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE (TC) ........................................ STORAGE TEMPERATURE .................................................... ISOLATION : INPUT/OUTPUT/CASE ..................................... INSULATION RESISTANCE .................................................... CASE ........................................................................................ FINISH ....................................................................................... WEIGHT ...................................................................................

-40° to +71°C -55° to +125°C 1050V RMS max. 200M-Ohms @ 500Vdc Hermetic seal Fuse Tin Plate 4 oz. max.

TERMINAL IDENTIFICATION A. B. C. D. E.

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT (+)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S449

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 BIDIRECTIONAL CURRENT TRANSDUCER SERIES S745 RESPONSE INPUT RANGE ACCURACY TIME BANDWIDTH PART NO. S745-40 ........... 0 to ±40 Adc.............. ±1 ................. 2u-sec ........ 175Khz ........... S745-75............ 0 to ±75 Adc.............. ±0.75 ............ 1.5u-sec ..... 233Khz ........... S745-150.......... 0 to ±150 Adc............ ±0.5 .............. 1.0u-sec ..... 350Khz ........... S745-250.......... 0 to ±250 Adc............ ±0.5 .............. 1.0u-sec ..... 350Khz ...........

TEMP. COEFF. .05% .04% .03% .03%

INPUT CURRENT RANGE NOMINAL .................................................. See Table OVERLOAD ............................................................ Unlimited (Nondestructive Nonlatching Saturated output) FREQUENCY RANGE ............................................ DC to 20KHz OUTPUT VOLTAGE SIGNAL ................................................. ACCURACY (ROOM TEMP) .................................. TEMPERATURE COEFFICIENT ............................ OUTPUT IMPEDANCE ........................................... RESPONSE TIME (10 TO 90%) ............................. BANDWIDTH .......................................................... OUTPUT PROTECTION ......................................... OUTPUT LOAD.......................................................

0 to ±5Vdc (Full Scale) % FS see table Per °C max. see table 10 Ohms max. Max. see table DC to see table Short Circuit 5K Ohm min.

POWER SUPPLY SUPPLY VOLTAGE ................................................ ±12Vdc (±1Vdc) CURRENT DRAIN .................................................. +15mA max -5mA max. PROTECTION......................................................... Reverse Polarity Protected

TERMINAL IDENTIFICATION A. B. C. D. E.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............................... -55 to +100°C STORAGE TEMPERATURE .................................. -55°C to +100 °C RADIATION............................................................. Operating as specified with a total dose of 1 KRAD (SI). SEL of 37 MeV (no latch or up-set). SHOCK ................................................................... 100 g, 6 m-sec half sine pulse VIBRATION............................................................. 50g HUMIDITY............................................................... 0 to 100% RH Operating INSULATION RESISTANCE................................... 500M-Ohms @ 500Vdc DIELECTRIC STRENGTH ..................................... 1500Vdc FINISH .................................................................... Fuse Tin Plate WEIGHT.................................................................. 0.49 lbs. Max.

SUPPLY (+) SUPPLY (RTN) SUPPLY (-) OUTPUT (+) OUTPUT (RTN)

AAC Code Ident. No. 15948

Drawing Number

700-S745A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739

Rev.


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES 929 PART CURRENT RANGE NUMBER 929-50.......................... 0 to ±50 929-75 .......................... 0 to ±75 929-100........................ 0 to ±100 929-150………………….0 to ±150

PART CURRENT NUMBER RANGE 929-200………………… 0 to ±200 929-250………………… 0 to ±250 929-300………………… 0 to ±300 929-400………………… 0 to ±400

INPUT RANGE ........................................................................... OVERLOAD CONTINUOUS ........................................... FREQUENCY RANGE....................................................

See Table Adc or AC Peak ±5000Adc DC to 350KHz

OUTPUT VOLTAGE SIGNAL ......................................................... ACCURACY (Over Temperature Range)........................ RESPONSE (10 to 90%)................................................. OUTPUT IMPEDANCE ................................................... LOAD RESISTANCE ..................................................... OUTPUT PROTECTION.................................................

0 to ±5Vdc FS ±1% FS (note 1) 1 u-sec. max. 25 Ohms 5k Ohms min Short Circuit

POWER SUPPLY SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... PROTECTION................................................................. TRANSIENT PROTECTION ...........................................

+10Vdc to +34Vdc 8mAdc max. Reverse polarity protected ±60V (T<5mS)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -40° to +85°C STORAGE TEMPERATURE RANGE............................. -55° to +125°C HUMIDITY (Operating).................................................... 0% to 95%RH MOISTURE RESISTANCE ............................................. MIL-STD-202 Method 106 (note 2) 2 RANDOM VIBRATION (Operating)................................. MIL-STD-810F, Proc.1,Cat.12, WO=.095G /Hz, Time1 hr, Fig. 514.5C-8 Overall level 12.G-RMS SHOCK ........................................................................... 50g 11m-sec. half sine pulse ISOLATION ..................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE........................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O (color light gray) WEIGHT ......................................................................... 6 oz. Max. NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. NOTE 2: Meets Specified Moisture requirements with option C & D only. TERMINAL IDENTIFICATION 1. 2.

SUPPLY VOLTAGE (+) SUPPLY (RTN)

3. 4.

OUTPUT (RTN) OUTPUT SIGNAL (+)

5-9. SPARE

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-929

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES S651 PART NUMBER S651-100-C S651-200-C

TERMINAL IDENTIFICATION A. B. C. D. E. F.

SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SINGAL (+) CASE GROUND SPARE

INPUT CURRENT RANGE 0 TO ±100Adc 0 TO ±200Adc

±100 TO ±125Adc ±200 TO ±250Adc

INPUT RANGE ................................................... See Table OVER RANGE CAPABILITY .................. See Table CURRENT OVERLOAD.......................... ± 5000 amps. DC continuous OUTPUT VOLTAGE SIGNAL ................................ 0 to ± 5Vdc FS ( ±5 to ±6.25Vdc OR ) ACCURACY ............................................ ± 1% (± 50mV) Over -10°C to +65°C LOW TEMP. OPERATION...................... @ -40°C to -10°C Accuracy / Linearity ±2.5% FS ACCURACY OVER RANGE(OR) ........... 2.5% FS LINEARITY.............................................. ±0.5% FS RESPONSE (10 TO 90%)....................... 100 u-sec max. OUTPUT LOAD CURRENT .................... 5mA max. OUTPUT IMPEDANCE ........................... 100 Ω max. POWER SUPPLY SUPPLY VOLTAGE ............................... +22 to 32Vdc CURRENT DRAIN .................................. 140mA max. REVERSE POLARITY PROTECTION.... 10uA max. current drain without damage TRANSIENT............................................ 40V for 20 m-sec ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............... -40°C to +65°C STORAGE TEMPERATURE .................. -55°C to +71°C OPERATING HUMIDITY......................... 0% to 95% RH MOISTURE RESISTANCE .................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE............................................... Operating: Sea Level to 27,000 FT. Non-Operating: Sea Level to 70,000Ft. 2 VIBRATION............................................. 20 to 40Hz + 6dB/ Octave 40 to 120Hz 0.02 G /Hz, 120 2 to 150 Slope By End Point, 150 to 800Hz 0.04 G /Hz, 800-2000 Hz -6dB/Octave ACCELERATION ................................... Operating ±5g’s In All Axes, Both Directions DIELECTRIC STRENGTH ..................... 350V RMS Terminals 1-5 & Case. INSULATION RESISTANCE .................. 1 MΩ @ 200Vdc ATTITUDE............................................... Unit Will Perform As Specified When Mounted In Any Position. SHOCK .................................................. Operating: 20g, Peak Terminal Sawtooth Pulse 11 Milli seconds Duration, All Planes, Both Directions. WEIGHT ................................................. 1.5 lbs. max. COMPONENTS DERATING (EEE COMPONENTS) ........ Derated To The Intent of Naval Air Systems Command AS-4613. MICROCIRCUITS ................................... MIL-M-38510 Class B QPL or DESC DWG. SEMICONDUCTORS.............................. MIL-S-19500 (JANTX) CAPACITORS......................................... MIL-C-39003, MIL-C-39014 (Level R) RESISTORS ........................................... MIL-R-39007, -39008, -39035,-55182 (Level R) TRANSFORMERS & INDUCTORS ........ MIL-T-27 (Class S)

AAC Code Ident. No. 15948

OVER RANGE

Drawing Number

Rev.

700-S651-942

H

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES S784 CURRENT PART CURRENT PART NUMBER RANGE NUMBER RANGE S784-100..............................0 to ±100 S784-400.............................. 0 to ±400 S784-200..............................0 to ±200 S784-500.............................. 0 to ±500 S784-250..............................0 to ±250 S784-600.............................. 0 to ±600 S784-300..............................0 to ±300 S784-750.............................. 0 to ±750 INPUT RANGE ............................................................................. See Table Adc FREQUENCY ................................................................... DC to 1kHz OVERLOAD CURRENT CONTINOUSE ......................... 10KAdc OUTPUT VOLTAGE SIGNAL........................................................... 0 to ±5Vdc FS ACCURACY...................................................................... ±1% FS RESPONSE TIME (10 TO 90%) ..................................... 500 u-sec. max. OUTPUT IMPEDANCE .................................................... 250 Ohms max. TEMPERATURE COEFFICIENT ..................................... ±.02%FS Per°c max. OUTPUT PROTECTION.................................................. Short CKT RECOMMEND OUTPUT LOAD....................................... 50KΩ or greater POWER SUPPLY SUPPLY VOLTAGE ......................................................... +16Vdc to +40Vdc nominal CURRENT DRAIN............................................................ 10mA max. REVERSE POLARITY PROTECTION ............................ 100µA max. Current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -40°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 MOUNTING ...................................................................... Rigid in any position INSULATION RESISTANCE............................................ 200 M-Ohms min. MIL-STD-202 Method 302 Test Condition A WEIGHT ........................................................................... 9 oz. max.

TERMINAL IDENTIFICATION A. B. C. D. E.

SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+) SPARE

CATEGORY SECTION DO-160D ENVIRONMENT TEMPERATURE & ALTITUDE A2 4 TEMPERATURE VARIATION A 5 HUMIDITY A 6 SHOCK & CRASH SAFTY REQ’D 7 VIBRATION H2 CURVE C&R 8 EXPLOSION PROOF X 9 FLUID SUSCEPTIBILITY X 11 SAND AND DUST X 12 FUNGUS RESISTANCE F 13 SALT SPRAY X 14 MAGNETIC EFFECT X 15 VOLTAGE SPIKE A 17 AUDIO FREQUENCY SUSCEPTIBILITY A 18 INDUCED SIGNAL SUSCEPTIBILITY A 19 RADIO FREQUENCY SUSCEPTIBILITY A 20 EMMISION OF RADIO FREQUENCY ENERGY Z 21 LIGHTNING INDUCED TRANSIENT SUSCEPTIBILITY A3C3 22 LIGHTNING DIRECT EFFECT X 23 STATIC DISCHARGE A

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S784

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES 947 TEMPERATURE INPUT CURRENT COEFFICIENT PART NO. 947-100 ................................ 0 to ±100................................... .02% 947-200 ................................ 0 to ±200................................... .01% 947-300 ................................ 0 to ±300.................................. .01% 947-400 ................................ 0 to ±400.................................. .01% 947-500 ................................ 0 to ±500.................................. .01% 947-600 ................................ 0 to ±600.................................. .01% INPUT RANGE ........................................................................................ Amps. DC or AC peak. See Table CURRENT OVERLOAD.............................................................. ±5000 amps. DC continuous FREQUENCY .............................................................................. DC to 100KHz OUTPUT VOLTAGE SIGNAL...................................................................... ACCURACY................................................................................. LINEARITY................................................................................... DI DT CAPABILITY...................................................................... DELAY TIME................................................................................ OUTPUT IMPEDANCE ............................................................... TEMPERATURE COEFFICIENT ................................................

0 to ±5Vdc FS (Full Scale) ± 0.5% FS ±0.1% FS 50A per u-sec 1 u-sec 100 Ohms max. % FS per °C. See Table

POWER SUPPLY SUPPLY VOLTAGE..................................................................... ±15Vdc ±1Vdc CURRENT DRAIN....................................................................... 150mA max. REVERSE POLARITY PROTECTION ....................................... 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................... STORAGE TEMPERATURE ...................................................... OPERATING HUMIDITY ............................................................. INSULATION RESISTANCE....................................................... ATTITUDE ...................................................................................

- 20° C to 70°C - 45°C to 85°C 0% to 95% RH 100 M-Ohms min. Unit will perform as specified when mounted in any position. SHOCK ........................................................................................ Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202 WEIGHT ...................................................................................... 1.5 lbs. max.

TERMINALS:

TERMINAL IDENTIFICATION

6-32 SCREWS, .325” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO .26” WIDE.

1. 2. 3. 4. 5.

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (±)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-947

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT SENSOR SERIES 943A TEMPERATURE INPUT CURRENT COEFFICIENT SUPPLY CURRENT PART NO. 943-100................... 0 to ±100 ......................... .04% ...................................... 85mA 943-200................... 0 to ±200 .......................... .04% ...................................... 115mA 943-300................... 0 to ±300 .......................... .02% ...................................... 165mA 943-400................... 0 to ±400 .......................... .02% ...................................... 215mA 943-500................... 0 to ±500 .......................... .02% ...................................... 265mA 943-600................... 0 to ±600 .......................... .01% ...................................... 265mA 943-750................... 0 to ±750 .......................... .01% ...................................... 265mA 943-800................... 0 to ±800 .......................... .01% ...................................... 265mA 943-1000................. 0 to ±1000 ......................... .01% ...................................... 265mA INPUT CURRENT RANGE ........................................................................................ CURRENT OVERLOAD.............................................................. FREQUENCY .............................................................................. OUTPUT VOLTAGE SIGNAL ..................................................................... ACCURACY................................................................................. LINEARITY .................................................................................. BANDWIDTH .............................................................................. RESPONSE TIME (10 to 90%) ................................................... OUTPUT IMPEDANCE ............................................................... TEMPERATURE COEFFICIENT................................................ POWER SUPPLY SUPPLY VOLTAGE .................................................................... CURRENT DRAIN....................................................................... REVERSE POLARITY PROTECTION ....................................... ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE .................................................. STORAGE TEMPERATURE ...................................................... OPERATING HUMIDITY............................................................. MOISTURE RESISTANCE .........................................................

MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.

ALTITUDE ................................................................................... RANDOM VIBRATION................................................................

DIELECTRIC STRENGTH.......................................................... INSULATION RESISTANCE ...................................................... ATTITUDE ................................................................................... TERMINAL IDENTIFICATION 12345-

Code Ident. No. 15948

A. SUPPLY VOLTAGE (+) B. SUPPLY & OUTPUT (RTN) C. SUPPLY VOLTAGE (-) D. OUTPUT SIGNAL (+) E. CASE GROUND F. SPARE

SHOCK ........................................................................................

WEIGHT ......................................................................................

AAC

Amps. DC or AC peak. See Table ±5000 amps. DC continuous DC to 350KHz 0 to ±5Vdc FS (Full Scale) ± 0.5% FS ±0.1% FS DC to 350KHz 1 u-sec 100 Ohms max. % FS per °C. See Table ±15Vdc ±1Vdc See Table mA max. 10µA max. current drain without damage - 55° C to +85°C - 55°C to +100°C 0% to 95% RH Will meet Method 106 of MIL-STD -202 & Method 507.1, Proc. 1 of MIL-STD-810 Operating: Sea level to 70,000 ft. Operating MIL-STD-810E Category 5, 2 Proc. 1, WO=0.012G Hz, duration 1 Hr. Figure 514. 4-8 suggested vibration levels for high performance Aircraft 12.5 G-RMS composite min. 350V RMS terminals 1-4 to 5 & case 100 M-Ohms min. Unit will perform as specified when mounted in any position. Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD202 1.5 lbs. max.

Drawing Number

Rev.

700-943A

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT SENSOR SERIES 944 INPUT RANGE PART NUMBER 944-600 ............................................... 0 TO ±600 944-800 ............................................... 0 TO ±800 944-1000 ........................................... 0 TO ±1000 944-1500 ........................................... 0 TO ±1500 944-2000 ........................................... 0 TO ±2000 INPUT CURRENT RANGE .............................................................................. Amps. DC or AC peak. See Table CURRENT OVERLOAD.................................................... ±5000 Amps. DC continuous. FREQUENCY .................................................................... DC to 20KHz OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ±5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS LINEARITY ........................................................................ ±.5% FS DI DT CAPABILITY ........................................................... 25A per u-sec OUTPUT IMPEDANCE ..................................................... 100 Ohms max. TEMPERATURE COEFFICIENT...................................... ±0.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. 50mA max. REVERSE POLARITY PROTECTION ............................. 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -55° to +85°C STORAGE TEMPERATURE ............................................ -55° to +100°C OPERATING HUMIDITY................................................... 0% to 95% RH MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE ......................................................................... Operating: Sea level to 70,000 ft. RANDOM VIBRATION...................................................... Operating MIL-STD-810E Category 5, Proc. 1, 2 WO=0.012G Hz, Duration 1 hr., Figure 514.4-8 Suggested Vibration levels for high performance Aircraft 12.5 G-RMS composite min. DIELECTRIC STRENGTH................................................ 350V RMS terminals 1-4 to 5 & case INSULATION RESISTANCE ............................................ 100 M-Ohms min. ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. SHOCK .............................................................................. Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202. WEIGHT ............................................................................ 1.5 lbs. Max. TERMINAL IDENTIFICATION 12345-

Code Ident. No. 15948

A. B. C. D. E. F.

SUPPLY VOLTAGE (+) SUPPLY & OUTPUT (RTN) SUPPLY VOLTAGE (-) OUTPUT SIGNAL (+) CASE GROUND SPARE

MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.

AAC

Drawing Number

Rev.

700-944

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES 948

INPUT CURRENT PART NUMBER 948-600 ............................................. 0 TO ±600 948-800 ............................................. 0 TO ±800 948-1000 ........................................... 0 TO ±1000 948-1500 ........................................... 0 TO ±1500 948-2000 ........................................... 0 TO ±2000 INPUT RANGE .............................................................................. Amps. DC or AC peak. See Table CURRENT OVERLOAD.................................................... ±5000 Amps. DC continuous FREQUENCY .................................................................... DC to 20KHz OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ±5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS LINEARITY ........................................................................ ±.5% FS DI DT CAPABILITY ........................................................... 25A per u-sec OUTPUT IMPEDANCE ..................................................... 100 Ohms max. TEMPERATURE COEFFICIENT...................................... ±0.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. 50mA max. REVERSE POLARITY PROTECTION .............................10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -20° to +70°C STORAGE TEMPERATURE ............................................ -45° to +85°C OPERATING HUMIDITY................................................... 0% to 95% RH INSULATION RESISTANCE ............................................ 100 M-Ohms min. ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. SHOCK .............................................................................. Operating: 50g, 11m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) WEIGHT ............................................................................ 1.5 lbs. max.

TERMINALS: 6-32 SCREWS, .325” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO .26” WIDE.

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (±)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-948

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES 909M4 REMOVEABLE YOKE TYPE INPUT RANGE MODEL NUMBER * 909M4-150........................................... 0 TO ±150 909M4-250........................................... 0 TO ±250 909M4-500........................................... 0 TO ±500 909M4-750........................................... 0 TO ±750 909M4-1000....................................... 0 TO ±1000 909M4-1500....................................... 0 TO ±1500 909M4-2000....................................... 0 TO ±2000 909M4-2500....................................... 0 TO ±2500 INPUT CURRENT RANGES........................................................ 0 to (FS) Full Scale, See Table CURRENT OVERLOAD................................................... 100 times FS OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE ...................................................................... TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE .................................................... OUTPUT SHORT-CIRCUIT DURATION.........................

0 to ±5Vdc FS ±1% FS 200 µ-sec. max. ±.05% FS/°C max. 100 Ohms max. Indefinite

POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±2Vdc SUPPLY BURDEN............................................................ +15Vdc 100mA max. -15Vdc 25mA max. PROTECTION .................................................................. Reverse Polarity Protection ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -25° to +75°C STORAGE TEMPERATURE RANGE ............................. -55° to +85°C ISOLATION....................................................................... Input/Output/Case (Supply & Output / Common) CASE MATERIAL ............................................................. Aluminum Casting FINISH .............................................................................. Black Anodize Finish WEIGHT ........................................................................... 18 oz.

BARRIER 1 2 3 4

TERMINAL IDENTIFICATION CONNECTOR OUTPUT SIGNAL (+) SUPPLY & OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SPARE SPARE

A B C D E F

*NOTE: SERIES 909M4 NORMALLY SUPPLIED WITH 4 TERMINAL BARRIER STRIP. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR PT02E10-6P OR EQUIVALENT. ADD LETTER “C” AFTER MODEL NUMBER FOR CONNECTOR OPTION. (REFERENCE: CONNECTOR MATES WITH PT06A10-6S (SR) OR EQUIVALENT).

BARRIER MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS AND .375 CENTER DISTANCES. TERMINALS ACCEPT WIRE SIZE UP TO #16 AWG WITH LUGS TO .281 IN. WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-909M4

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

BIDIRECTIONAL CURRENT TRANSDUCER SERIES 9000 REMOVABLE YOKE TYPE PART NO.

INPUT RANGE

9000-150......................0 to ±150 9000-250......................0 to ±250 9000-500......................0 to ±500 9000-750......................0 to ±750

PART NO.

9000-1000................................ 0 to ±1000 9000-1500................................ 0 to ±1500 9000-2000................................ 0 to ±2000 9000-2500................................ 0 to ±2500

INPUT CURRENT RANGE................................................................... CURRENT OVERLOAD............................................................

See Table Unlimited Nondestructive

OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... RESPONSE (10 to 90%) ........................................................... OUTPUT IMPEDANCE ............................................................. TEMPERATURE COEFFICIENT.............................................. SHORT CIRCUIT DURATION..................................................

0 to ±5Vdc FS (Full Scale) ±1% FS 200 u-sec max. 100Ω max. ±0.05% FS/°C typ Continuous

POWER SUPPLY SUPPLY VOLTAGE ................................................................. CURRENT DRAIN..................................................................... REVERSE POLARITY .............................................................. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... ISOLATION ............................................................................... CASE MATERIAL ..................................................................... WEIGHT ...................................................................................

TERMINAL IDENTIFICATION BARRIER 1 2 3 4 5

A B C D E F

-25° to +75°C -55° to +85°C Input/Output/Case (Supply & Output Common) Molded Plastic Meets UL Flammability Rating 94V- 0 12 oz. max.

1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16AWG AND WIRE LUGS TO .250 IN. WIDE. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER C AFTER PART NUMBER FOR CONNECTOR OPTION.

AAC Code Ident. No. 15948

±15Vdc ±1Vdc 100mA max. at +15Vdc 25mA max. at -15Vdc No damage, 10uA current drain

NOTE:

CONNECTOR OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+15V) SUPPLY VOLTAGE (RTN) SUPPLY VOLTAGE (-15) SPARE

INPUT RANGE

Drawing Number

Rev.

700-9000

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER PART NUMBER S630-2500

INPUT MEASURING RANGE (CONTINUOUS) (TRANSIENT) .....

0 to ± 1000Adc FS (Full Scale) 1422A RMS (1 min) 1375A RMS (4 min) 1161A RMS (30 min) 2168A peak (5 sec.) 2514A tr (18 M-sec.)

OUTPUT CURRENT SIGNAL ................................. TURN RATIO ........................................... ACCURACY ............................................ LINEARITY .............................................. LOAD........................................................ RESPONSE .............................................

250uA per 1A Input 4000 to 1 0.5% FS (-25 to +70°C) ± 0.1% max. up to 630mA max. 5.5 Ohms max. 1M-sec. max.

POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... PROTECTION .........................................

±24Vdc ±1Vdc 650mA max. Reverse Polarity Protected

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE................... -40°C to +85°C SHOCK & VIBRATION ........................... IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ....................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 200 M-ohms @ 500Vdc DIELECTRIC STRENGTH ..................... 3.3Kv RMS 60Hz PRIMARY BAR VOLTAGE ..................... 2Kv RMS max. CASE........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 6.5 lbs. max.

NOTE: 1. MOULDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-005.RFP (XIL). 4 .RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.

TERMINAL IDENTIFICATION

1. 2. 3. 4. 5.

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) OUTPUT SPARE SPARE

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S630

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES 903B

PART NO.

INPUT CURRENT RANGE

903B-5 .........................0-5mA 903B-10 .......................0-10mA 903B-20 .......................0-20mA 903B-50 .......................0-50mA 903B-100 .....................0-100mA

PART NO.

INPUT CURRENT RANGE

903B-200 ................................. 0-200mA 903B-500 ................................. 0-500mA 903B-1A................................... 0-1A 903B-2A................................... 0-2A 903B-5A...................................0-5A

OUTPUT VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RIPPLE .............................................................................. 2% FS RMS max. IMPEDANCE ..................................................................... 1000 Ohms ±5%, 5mA to 1A range 500 Ohms ±5%, 2A 200 Ohms ±5%, 5A RESPONSE....................................................................... 50 m-sec. max. ( 10 to 90%) TEMPERATURE COEFFICIENT...................................... ±.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 50mAdc max. REVERSE POLARITY PROTECTION ............................. 10µA current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -55°C to +85°C STORAGE TEMPERATURE RANGE .............................. -60°C to +100°C INSULATION RESISTANCE ............................................ 100 M-ohms (all terminals to case) DIELECTRIC STRENGTH................................................ 350V RMS (all terminals to case) ALTITUDE ......................................................................... Operating sea level to 60,000 ft. VIBRATION ....................................................................... Operating - 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK .............................................................................. Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE ............................................... Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Meets spec. for any mounting position RIPPLE .............................................................................. 40mV reflected onto pass-thru line WEIGHT ............................................................................ 1.25 lbs. max.

TERMINAL IDENTIFICATION A. B. C. D. E. F.

Code Ident. No. 15948

SUPPLY VOLTAGE (+) SUPPLY AND SIGNAL (RTN) OUTPUT SIGNAL (+) SPARE SPARE CASE GROUND

AAC

Drawing Number

Rev.

700-903B

M

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES S767 CURRENT PART NUMBER RANGE S767-10 ...............................0 to 10mA S767-20 ...............................0 to 20mA S767-50 ...............................0 to 50mA S767-100 .............................0 to 100mA

PART CURRENT NUMBER RANGE S767-200 ........................... 0 to 200mA S767-250 ........................... 0 to 250mA S767-500 ........................... 0 to 500mA S767-1A............................. 0 to 1A

INPUT CURRENT RANGE.................................. See Table CURRENT OVERLOAD........................... 100Adc

TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY (RTN) C. OUTPUT SIGNAL (+) D. OUTPUT (RTN) E. CASE GROUND

OUTPUT VOLTAGE SIGNAL .................................. ACCURACY.............................................. OUTPUT IMPEDANCE ............................ RIPPLE ..................................................... TEMPERATURE COEFFICIENT............. LONG TERM STABILITY......................... RESPONSE (10 TO 90%)........................ PROTECTION..........................................

0 to +5Vdc FS (Full Scale) ± 1% FS (±50mV) 100 Ohms max. 1% FS (RMS) max. ±.02% FS/°C max. ±.2% FS/yr 50 m-sec max. Continuous Short ckt Without damage

POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN.................................... OVER VOLTAGE PROTECTION............ REVERSE POLARITY PROTECTION ....

22Vdc to 36Vdc 12mAdc Terminals A & B ±36Vdc without damage 10µA max. current drain

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -40° to +85°C STORAGE TEMPERATURE ................... -55° to +85°C HUMIDITY ................................................ 0% to 95% RH MOISTURE RESISTANCE ...................... MIL-STD-810, Method 507.1, Proc. I -5 ALTITUDE ................................................ Sea Level to 10 torr (Hard Vacuum) PYROSHOCK (PROTO FLIGHT) ........... 100Hz @ 50g +6dB/Oct to 1100g @ 1KHz flat to 10KHz VIBRATION (SINE) .................................. 0.06 In. D.A., 10 to 55 Hz (RANDOM) ............................................... Overall 37.9g’s 20 to 50 Hz 2 +12db/octave 0.084 to 3.0g /Hz. 3.0 flat. 130 to 300 Hz -6db/octave 2 3.0 to .6g /Hz. 300 to 1 flat 2 1500 to 2000 Hz -6db/octave 0.60 to 0.33g /Hz. INSULATION RESISTANCE .................. 100 M-Ohms min. @ 100Vdc ATTITUDE ................................................ Performs in any position. FINISH ...................................................... Fuse Tin Plate ENCAPSULANT....................................... Stycast 2850FT Cat 11 WEIGHT ................................................... .49lbs max.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S767-903

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES 936

PART NO.

INPUT CURRENT AMPS DC

936-10 ......................... 0 TO 10mA 936-20 ......................... 0 TO 20mA 936-50 ......................... 0 TO 50mA 936-100 ....................... 0 TO 100mA 936-200 ....................... 0 TO 200mA

INPUT CURRENT AMPS DC

PART NO.

936-250.................................... 0 TO 250mA 936-500................................... 0 TO 500mA 936-1A .................................... 0 TO 1A 936-2A .................................... 0 TO 2A 936-5A ..................................... 0 TO 5A

INPUT CURRENT RANGE (Adc) ................................................ TRANSIENT PROTECTION VOLTAGE OF THRU CABLE..................................... VOLTAGE TRANSIENT ............................................. CURRENT TRANSIENT ............................................ REFLECTED RIPPLE (THRU CABLE)............................ OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE (10 TO 90%) ................................................ RIPPLE ............................................................................. TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE (±5%)..........................................

See Table 35KV (with insulated cable) 500 Volts/u-sec 500 Amps/u-sec 40mV

0 to +5Vdc FS (Full Scale) ±1% FS (±50mV) 100 m-sec. max. 2% FS RMS max. ± 0.1% FS/°C max. 1000 Ohms (Ranges 10mA to 1A) 500 Ohms (Range 2A) 200 Ohms (Range 5A)

POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................ 75mAdc max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C INSULATION RESISTANCE............................................ 100 K-Ohms WEIGHT ........................................................................... 28 oz. max.

TERMINAL IDENTIFICATION A. B. C. D. E. F.

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT (RTN) SPARE OUTPUT (+) CASE GROUND

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-936

H

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES S218

PART NO.

INPUT CURRENT RANGE

S218-100..................... 0 TO 100mA S218-200..................... 0 TO 200mA S218-500..................... 0 TO 500mA

PART NO.

INPUT CURRENT RANGE

S218-1A ................................... 0 TO 1A S218-2A .................................. 0 TO 2A S218-5A .................................. 0 TO 5A

OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RIPPLE ............................................................................. IMPEDANCE.....................................................................

0 to +5Vdc FS (Full Scale) ±1% FS (±50mV) 2% FS RMS max. 1000 Ohms ±5%, 100mA to 1A range 500 Ohms ±5%, 2A 200 Ohms ±5%, 5A RESPONSE ...................................................................... 50 m-sec max. (10 to 90%) TEMPERATURE COEFFICIENT ..................................... ± .04%/°C max.

POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................ 65mAdc max. REVERSE POLARITY PROTECTION ............................ 10µA max. Current Drain- no damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -60°C to +100°C INSULATION RESISTANCE............................................ 100 M-Ohms (terminals 1,2,3,&4 to case) DIELECTRIC STRENGTH ............................................... 350V RMS (terminals 1,2,3,&4 to case) ALTITUDE......................................................................... Operating sea level to 60,000 ft. VIBRATION....................................................................... Operating - 0.06 in. D.A., 10 to 55Hz Method 201 of MIL-STD-202. SHOCK ............................................................................. Operating 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202. MOISTURE RESISTANCE .............................................. Will meet Method 106 of MIL-STD-202 and Method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY .................................................. 0 to 95% RH ATTITUDE ........................................................................ Meets spec. for any mounting position. RIPPLE ............................................................................. 40mV reflected onto pass-thru line. WEIGHT ........................................................................... 1.5 lbs. Max.

NOTE: MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT SIGNAL (RTN) OUTPUT SIGNAL (+) CASE GROUND

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S218-903

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 DC CURRENT TRANSDUCER SERIES S619 PART NUMBER

CURRENT RANGE

OVERLOAD

S619-3.5 S619-10

0 TO 3.5A 0 TO 10A

0 TO ±5A 0 TO ±15A

TRANSIENT 250 750

INPUT IMPEDANCE 5 1.75

INPUT CURRENT CURRENT RANGE .................................................................. See Table OVERLOAD .............................................................................. See Table continuous TRANSIENT OVERLOAD ........................................................ See Table sec / hr max. ISOLATION............................................................................... 500V RMS, 60Hz 1 min. INPUT IMPEDANCE................................................................. See Table milli-Ohms max. OUTPUT VOLTAGE SIGNAL................................................................... 0 to +3.5Vdc FS (Full Scale) ACCURACY (@ 25°C).............................................................. ± 2% FS (± 70mV) RESPONSE (0 to 90%) ............................................................ 1 m-sec OUTPUT IMPEDANCE ............................................................ 50 Ohms max. TEMPERATURE COEFFICIENT ............................................. .04% FS /°C max. LOAD IMPEDANCE.................................................................. 10K-Ohms min. POWER SUPPLY (PS) SUPPLY VOLTAGE ................................................................. +5Vdc ± .5Vdc CURRENT DRAIN.................................................................... 5mAdc max. POWER SUPPLY PROTECTION............................................ 0 to +12Vdc withstanding without damage

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5. 6.

INPUT CURRENT (+) INPUT CURRENT (-) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT SIGNAL (RTN) OUTPUT SIGNAL (+)

NOTE: TERMINALS 4 & 5 ARE ELECTRICALLY COMMON.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. -55° to +85°C STORAGE TEMPERATURE RANGE ..................................... -55° to +105°C OPERATING HUMIDITY .......................................................... 0% to 95% RH MOISTURE RESISTANCE ...................................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Procedure I of MIL-STD-810 -8 PRESSURE .............................................................................. 1 X 10 torr. SHOCK ..................................................................................... Operating: 50g, 11 m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) VIBRATION .............................................................................. MIL-STD-202F Method 214 Test Condition G 26.4 GRMS overall DIELECTRIC STRENGTH ....................................................... 350V RMS dielectric withstanding voltage (Method 301 of MIL-STD-202) INSULATION RESISTANCE.................................................... 10 M-ohms min. (Method 302, Condition A of MIL-STD-202) ATTITUDE ................................................................................ Unit will perform as specified when mounted in any position. ENCAPSULANT ...................................................................... Stycast 2850FT Cat 11 CASE ........................................................................................ Diallylpthlalate MIL-M-14F,SDG WEIGHT ................................................................................... 1 oz. Typ.

NOTE: APPLY RTV 133 ADHESIVE (OR EQUIVALENT) 360° AROUND BOTTOM OF UNIT AFTER INSTALLING TO MEET ENVIRONMENTAL CHARACTERISTICS.

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-S619

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES 950 INPUT CURRENT RANGE (AMPS DC) MODEL NUMBER 950-10 ........................................................ 0 - 10 950-20 ........................................................ 0 - 20 950-30 ........................................................ 0 - 30 950-40 ........................................................ 0 - 40 950-50 ........................................................ 0 - 50 OUTPUT VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) ACCURACY....................................................................... ±0.5% FS (±25mV) for 20,30,40, & 50A models ±1% FS (±50mV) for 10A model RESPONSE (10 TO 90%)................................................. 10 m-sec. max. RIPPLE .............................................................................. 25mV (RMS) max. TEMPERATURE COEFFICIENT...................................... ±.02% FS/°C LONG TERM STABILITY.................................................. ±0.1% FS/yr OUTPUT IMPEDANCE ..................................................... 4000 ohms max. OUTPUT PROTECTION .................................................. Output terminals E & C will withstand ±250Vdc for 10m-sec, ±60Vdc continuously, short circuit POWER SUPPLY (PS) SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 70mAdc max. OVER VOLTAGE PROTECTION..................................... Terminals A & B withstand ±35Vdc without damage REVERSE POLARITY PROTECTION ............................. 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -25° to +85°C STORAGE TEMPERATURE RANGE .............................. -55° to +85°C DIELECTRIC STRENGTH................................................ 350 V RMS dielectric withstanding voltage (method 301 of MIL-STD-202) INSULATION RESISTANCE ............................................ 10 M-ohms min. (method 302, Condition A of MIL-STD-202) ALTITUDE ......................................................................... Operating: sea level to 60,00 ft. Non-operating: sea level to 120,000 ft. (method 105, Condition A of MIL-STD-202) VIBRATION ....................................................................... Operating: 0.06 inch D.A., 10 to 55 Hz (method 201 of MIL-STD-202) SHOCK .............................................................................. Operating: 50g, 11 m-sec half sine pulse (method 213, Condition A of MIL-STD-202) MOISTURE RESISTANCE ............................................... Will meet method 106 of MIL-STD-202 and Method 507.1, Procedure I of MIL-STD-810 OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position TERMINAL IDENTIFICATION A. B. C. D. E. F.

Code Ident. No. 15948

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT (RTN) SPARE OUTPUT (+) CASE GROUND

AAC

Drawing Number

Rev.

700-950

F

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES 913B

PART NO.

INPUT CURRENT RANGE

913B-10....................... 0 TO 10A 913B-15....................... 0 TO 15A 913B-20....................... 0 TO 20A 913B-25....................... 0 TO 25A 913B-30....................... 0 TO 30A

PART NO.

INPUT CURRENT RANGE

913B-35 ................................... 0 TO 35A 913B-40 .................................. 0 TO 40A 913B-50 .................................. 0 TO 50A 913B-75 .................................. 0 TO 75A 913B-100 ................................ 0 TO 100A

INPUT CURRENT RANGE ............................................................................. See Table OVER CURRENT (UNLIMITED)...................................... Nondestructive/nonlatching Saturated Output OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE ( 10 TO 90%) ............................................... IMPEDANCE.....................................................................

0 to +5Vdc FS (Full Scale) ±1% FS 1 m-sec. max. 100Ω max. for 10A to 50A ranges 275Ω for 75A to 100A ranges RIPPLE ............................................................................. 10mV RMS max. TEMPERATURE COEFFICIENT ..................................... ±0.02% FS/°C max. OUTPUT PROTECTION.................................................. Terminals D & E will withstand ±32Vdc or short circuit

POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................ 75mA max. REVERSE POLARITY PROTECTION ............................ 10µA max. Current drain without damage

TERMINAL IDENTIFICATION A. B. C. D. E. F.

Code Ident. No. 15948

SPARE SPARE +28Vdc D.C. COMMON 0 TO +5V OUTPUT CASE GROUND

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 INSULATION RESISTANCE............................................ 200 M-ohms min. MIL-STD-202 Method 302 Test Condition A ALTITUDE......................................................................... Operating sea level to 100,000 ft., MIL-STD-202, Method 105, Condition D VIBRATION....................................................................... Operating 0.06 in. D.A., 10Hz to 55 Hz MIL-STD-202 Method 201 SHOCK ............................................................................. Operating 50 g, 11 m-sec MIL-STD-202 Method 213, Condition A MOISTURE RESISTANCE .............................................. MIL-STD-202 Method 106 OPERATING HUMIDITY .................................................. 0% to 95% RH ATTITUDE ........................................................................ Meets spec. for any mounting position WEIGHT ........................................................................... 12 oz. max.

AAC

Drawing Number

Rev.

700-913B

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(6316) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES 913A PART NO.

INPUT CURRENT

913A-10....................... 0 to 10A 913A-20....................... 0 to 20A 913A-25....................... 0 to 25A 913A-30....................... 0 to 30A

PART NO.

INPUT CURRENT

913A-40 ................................... 0 to 40A 913A-50 .................................. 0 to 50A 913A-75 .................................. 0 to 75A 913A-100 ................................ 0 to 100A

INPUT RANGE ............................................................................. See Table OVER CURRENT (UNLIMITED)...................................... Nondestructive/nonlatching Saturated Output OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE(10 TO 90%) ................................................. IMPEDANCE.....................................................................

0 to +5Vdc FS (Full Scale) ±1% FS 1 m-sec max. 100Ω for 10A to 50A ranges 1000Ω for 75A to 100A ranges RIPPLE ............................................................................. 10mV RMS max. TEMPERATURE COEFFICIENT ..................................... ±0.02% FS/°C max. for 10A & 50a RANGES ±0.04% for 75A & 100A ranges OUTPUT PROTECTION.................................................. Terminals D & E will withstand +32Vdc or short circuit

POWER SUPPLY SUPPLY VOLTAGE ......................................................... +28Vdc ±4Vdc CURRENT DRAIN............................................................ 75mA max. REVERSE POLARITY PROTECTION ............................ 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 INSULATION RESISTANCE............................................ 200M-Ohms min. MIL-STD-202 Method 302 Test Condition A ALTITUDE......................................................................... Operating sea level to 100,000 ft. MIL-STD-202, Method 105, Condition D VIBRATION....................................................................... Operating 0.06 in D.A., 10Hz to 55Hz MIL-STD202, Method 201 SHOCK ............................................................................. Operating 50g 11 m-sec MIL-STD-202, Method 213, Condition A MOISTURE RESISTANCE .............................................. MIL-STD-202, Method 106 OPERATING HUMIDITY .................................................. 0 to 95% RH ATTITUDE ........................................................................ Meets specification for any mounting position WEIGHT ........................................................................... 9 oz. max. TERMINAL IDENTIFICATION A. SPARE B. SUPPLY VOLTAGE (RTN) C. SUPPLY VOLTAGE (+) D. OUTPUT SIGNAL (RTN) E. OUTPUT SIGNAL (+) F. CASE GROUND TERMINALS B & D ARE COMMON

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-913A

T

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES S770 PART CURRENT NUMBER RANGE S770-20 .........................0 to 20 S770-25 .........................0 to 25 S770-30 .........................0 to 30 S770-40 .........................0 to 40

PART CURRENT NUMBER RANGE S770-50…………………0 to 50 S770-60…………………0 to 60 S770-70…………………0 to 70 S770-100……………….0 to 100

INPUT RANGE .............................................................................. OVERLOAD CONTINUOUS............................................. FREQUENCY RANGE ......................................................

See Table ±2000Adc DC to 350Hz

OUTPUT VOLTAGE SIGNAL ........................................................... ACCURACY....................................................................... RESPONSE (10 to 90%) ................................................... OUTPUT IMPEDANCE ..................................................... LOAD RESISTANCE ........................................................ TEMPERATURE COEFFICIENT...................................... OUTPUT PROTECTION ..................................................

0 to+5Vdc ±1% FS 1 m sec. 10 Ohms 10k Ohms min ±.02%FS per °c max. Short Circuit

POWER SUPPLY SUPPLY VOLTAGE ......................................................... CURRENT DRAIN............................................................. PROTECTION................................................................... TRANSIENT PROTECTION.............................................

+12Vdc to +36Vdc 10mAdc max. Reverse polarity protected ±60V (T<5mS)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -40° to +85°C STORAGE TEMPERATURE RANGE .............................. -40° to +85°C ISOLATION ....................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE ............................................ 500 M-Ohms @ 500Vdc CASE MATERIAL.............................................................. Molded Plastic meets UL flammability rating 94V-O WEIGHT ........................................................................... 10 oz. Max.

TERMINAL IDENTIFICATION 1. 2.

3. 4.

SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+)

TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S770

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .06 .XXX ± .030

DC CURRENT TRANSDUCER SERIES 920 4 TO 20 mA 2 WIRE LOOP POWER CLAMP ON PART NO 920-50 920-75 920-100 920-125

TERMINAL IDENTIFICATION PIN 1 : POWER PIN 2 : RTN PIN 3 : N.C. PIN 4 : N.C. PIN 5 : N.C.

CURRENT RANGE 0 TO 50Adc 0 TO 75Adc 0 TO 100Adc 0 TO 125Adc

INPUT RANGE ........................................................................... OVERLOAD CONTINUOUS........................................... FREQUENCY RANGE....................................................

See table ±5000Adc DC to 35Hz

OUTPUT CURRENT SIGNAL ........................................................ ACCURACY (Over Temperature Range) ...................... RESPONSE (10 to 90%) ................................................ LOAD RESISTANCE (RL) .............................................. LOAD RESISTANCE RANGE ....................................... CURRENT SIGNAL @ OVERLOAD............................... PROTECTION ................................................................

4 to 20mAdc See table & Note 1 %FS (Full Scale) 10 m sec. 250 Ohms Nominal 0 to 300 Ohms 24 mAdc typ. Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... SUPPLY VOLTAGE RANGE .......................................... TRANSIENT PROTECTION ...........................................

+24Vdc Nominal 4 to 24mAdc +18 to 28Vdc ±40V (T<5mS)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE......................... -40° to +85°C STORAGE TEMPERATURE RANGE ............................ -45° to +85°C ISOLATION..................................................................... Input to output 2KV rms 60Hz/1min. INSULATION RESISTANCE .......................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O WEIGHT ......................................................................... 14 oz. Max. FINISH ............................................................................ Blue Textured Pantone No. 294C NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. 2: Insert tool and press to release. (Recommended Tool : Screwdriver, 3/16 standard tipped)

AAC Code Ident. No. 15948

ACCURACY 1.25% 1.0% 1.0% 1.0%

Drawing Number

Rev.

700-920

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SPLIT CORE PART. NO.

SELECTABLE MEAS. RANGE

OUTPUT SIGNAL

DCT-05-100 DCT-05-200 DCT-05-300 DCT-05-400 DCT-20-100 DCT-20-200 DCT-20-300 DCT-20-400

50, 75, 100A 100, 150, 200A 150, 225, 300A 200, 300, 400A 50, 75, 100A 100, 150, 200A 150, 225, 300A 200, 300, 400A

0-5VDC 0-5VDC 0-5VDC 0-5VDC 4-20mA 4-20mA 4-20mA 4-20mA

SPECIFICATIONS Output Signal Output Output Limit Accuracy Repeatability Response Time Frequency Range Power Supply Power Consumption Loading

4-20mA or 0-5VDC 4-20mA: 44mA 0-5vdc:: 13VDC 1.0% FS 1.0%FS 100mS (to 90% of step change) DC 20-50VDC, 22-38VAC power input and output signal are not isolated. 2VA 4-20mA:: 650Ω max.

0-5VDC: 250KΩ for rated accuracy; 25KΩ, add 1% error. Isolation Voltage Linearity Current Ranges Sensing Aperture Case Environmental

3KV (monitored line output) 0.75% FS Field selectable ranges from 0-400A. 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -4 to 122° F (-20 to 50° C), 0-95% RH, non-condensing

DCT-

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- DCT

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES S728B AAC PART NUMBER S728B-50 S728B-100 S728B-150 S728B-200 S728B-250 S728B-300 S728B-400

TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT SIGNAL (RTN) D. OUTPUT SIGNAL (+) E. CASE GROUND

INPUT CURRENT RANGE 0 to 50Adc 0 to 100Adc 0 to 150Adc 0 to 200Adc 0 to 250Adc 0 to 300Adc 0 to 400Adc

OUTPUT ACCURACY (SEE NOTE 1) @25°C 0 to 70°C -55to85°C ±0.5% ±0.8% ±1.5% ±0.5% ±0.6% ±1.0% ±0.5% ±0.6% ±1.0% ±0.5% ±0.6% ±0.8% ±0.5% ±0.6% ±0.8% ±0.4% ±0.5% ±0.8% ±0.3% ±0.4% ±0.6%

SUPPLY CURRENT DRAIN 40mA 40mA 50mA 50mA 65mA 80mA 110mA

INPUT CURRENT RANGE .................................................... CURRENT OVERLOAD..........................

See Table 5000Adc Continuous (Nonlatching/Saturated Output)

OUTPUT CURRENT SIGNAL................................. ACCURACY............................................. LINEARITY............................................... BANDWIDTH........................................... RESPONSE TIME ( 10 to 90%)............... OUTPUT IMPEDANCE ...........................

0 to 5Vdc FS (Full Scale) % FS See Table & Note 1 ±0.1% FS. DC TO 350KHZ 1 u-sec. 50 Ohms max.

POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN................................... REVERSE POLARITY PROTECTION ...

28Vdc ±4Vdc See Table 100uA Current Drain Without Damage

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............... -55 to +85°C STORAGE TEMPERATURE .................. -55 to +90°C OPERATING HUMIDITY ......................... 0% to 95% RH MOISTURE RESISTANCE .................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE ............................................... Operating sea level to 60,000 ft. Non-operating - sea level to 120,000 ft. (Method 105, Condition A of MIL-STD-202) SHOCK ................................................... Non-Operating - 50g, 11 m-sec half sine pulse (Method 213 Condition A of MIL-STD-202) 2 RANDOM VIBRATION ............................ Operating MIL-STD-810E Cat.5, Proc.1, WO=0.012G /HZ, Duration 1 hr., Figure 514.4-8 Suggested Vibration Levels for High Performance Aircraft 12.5G-RMS Min. DIELECTRIC STRENGTH ..................... 350V RMS Terminals A-D to E & Case INSULATION RESISTANCE .................. 100 M-Ohms Min. FINISH .................................................... Fuse Tin Plate ALTITUDE................................................ Unit will perform as specified when mounted in any position WEIGHT ................................................. 0.57 lbs. max.

NOTE: Specified accuracy includes the combined worst case effects of Zero Offset, Hysteresis, Supply Swings and Current Cable Positioning

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S728B-952

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES 952 AAC PART NUMBER 952-50 952-100 952-150 952-200 952-250 952-300 952-400 952-500 952-600 952-750

TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT SIGNAL (RTN) D. SPARE E. OUTPUT SIGNAL (+) F. CASE GROUND

INPUT CURRENT RANGE 0 to 50Adc 0 to 100Adc 0 to 150Adc 0 to 200Adc 0 to 250Adc 0 to 300Adc 0 to 400Adc 0 to 500Adc 0 to 600Adc 0 to 750Adc

OUTPUT ACCURACY OUTPUT (SEE NOTE 1) IMPEDANCE @25°C 0 to 70°C -55to85°C OHMS ±0.5% ±0.8% ±1.5% 100 ±0.5% ±0.6% ±1.0% 100 ±0.5% ±0.6% ±1.0% 70 ±0.5% ±0.6% ±0.8% 50 ±0.5% ±0.6% ±0.8% 40 ±0.4% ±0.5% ±0.8% 33 ±0.3% ±0.4% ±0.6% 50 ±0.3% ±0.4% ±0.6% 40 ±0.3% ±0.4% ±0.6% 33 ±0.3% ±0.4% ±0.6% 26

INPUT CURRENT RANGE .................................................... See Table CURRENT OVERLOAD.......................... 5000 Adc Continuous ( Nonlatching/Saturated Output) OUTPUT VOLTAGE SIGNAL.................................. 0 to +5 Vdc FS (Full Scale) ACCURACY............................................. % FS See Table & Note 1 LINEARITY............................................... ±0.1% FS DI/DT ACCURATELY FOLLOWED ........ 100 A/u-sec. BANDWIDTH........................................... DC TO 100KHZ RESPONSE TIME ................................... <1 u-sec. OUTPUT IMPEDANCE ........................... See Table POWER SUPPLY SUPPLY VOLTAGE ................................ 28Vdc ±4Vdc CURRENT DRAIN................................... See Table REVERSE POLARITY PROTECTION ... 10uA Current Drain Without Damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............... -55 to +85°C STORAGE TEMPERATURE .................. -55 to +85°C OPERATING HUMIDITY ......................... 0% to 95% RH MOISTURE RESISTANCE .................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE ............................................... Operating sea level to 60,000 ft. Non-operating - sea level to 120,000 ft. (Method 105, Condition A of MIL-STD-202) SHOCK ................................................... Non-Operating - 50g, 11 m-sec half sine pulse (Method 213 Condition A of MIL-STD-202) 2 RANDOM VIBRATION ............................ Operating MIL-STD-810E Cat.5, Proc.1, WO=0.012G /HZ, Duration 1 hr., Figure 514.4-8 Suggested Vibration Levels for High Performance Aircraft 12.5G-RMS Min. DIELECTRIC STRENGTH ..................... 350V RMS Terminals 1-5 to 6 & Case INSULATION RESISTANCE .................. 100 M-Ohms Min. ALTITUDE................................................ Unit will perform as specified when mounted in any position WEIGHT ................................................. 1.21 lbs. max.

NOTE: Specified accuracy includes the combined worst case effects of Zero Offset, Hysteresis, Supply Swings and Current Cable Positioning

AAC Code Ident. No. 15948

SUPPLY CURRENT DRAIN 40mA 40mA 60mA 65mA 80mA 100mA 75mA 100mA 140mA 185mA

Drawing Number

Rev.

700-952

K

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES S347 REMOVABLE YOKE TYPE

PART NO.

INPUT CURRENT RANGE

S347-100..................... 0 TO 100A S347-150..................... 0 TO 150A S347-200..................... 0 TO 200A S347-225..................... 0 TO 225A S347-250..................... 0 TO 250A S347-300..................... 0 TO 300A

INPUT CURRENT RANGE

PART NO.

S347-500 ................................. 0 TO 500A S347-750 ................................ 0 TO 750A S347-1000 .............................. 0 TO 1000A S347-1500 .............................. 0 TO 1500A S347-2000 ............................... 0 TO 2000A S347-2500 ............................... 0 TO 2500A S347-5000 ............................... 0 TO 5000A

INPUT CURRENT RANGE .......................................................... 0 to Full Scale (FS) See Table CURRENT OVERLOAD................................................... 100 times FS OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE ...................................................................... TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE ....................................................

0 to +5Vdc (FS) ±1% FS (±50mV) 200 µ-sec. max. ± .05% FS/°C 100 Ohms max.

SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc SUPPLY BURDEN............................................................ 100mA max. PROTECTION .................................................................. Reverse Polarity Protection ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -25°C to +75°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C ISOLATION....................................................................... Input/Output/Case (Supply & Output common) CASE MATERIAL ............................................................. Aluminum Casting FINISH .............................................................................. Black Anodize Finish WEIGHT ........................................................................... 18 oz.

TERMINAL IDENTIFICATION CONNECTOR A B C D E F

SIGNAL OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE

MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS AND .375 CENTER DISTANCES. TERMINALS ACCEPT WIRE SIZE UP TO #16 AWG. WITH LUGS TO .281 IN. WIDE.

Code Ident. No. 15948

BARRIER 1 2 3 4

NOTES: 1. SERIES S347-909 NORMALLY SUPPLIED WITH 4 TERMINAL BARRIER STRIP AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER -C AFTER PART NUMBER FOR CONNECTOR OPTION. (REFERENCE: CONNECTOR MATES WITH PT06A-10-6S (SR) OR EQUIVALENT.

AAC

Drawing Number

Rev.

700-S347-909

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .06 .XXX ± .030

DC CURRENT TRANSDUCER SERIES 921 4 TO 20 mA 2 WIRE LOOP POWER CLAMP ON PART NO 921-200 921-250 921-300 921-400 921-500 921-750 921-1000 921-1500 921-2000

TERMINAL IDENTIFICATION PIN 1 : POWER PIN 2 : RTN PIN 3 : N.C. PIN 4 : N.C PIN 5: N.C.

CURRENT RANGE 0 TO 200Adc 0 TO 250Adc 0 TO 300Adc 0 TO 400Adc 0 TO 500Adc 0 TO 750Adc 0 TO 1000Adc 0 TO 1500Adc 0 TO 2000Adc

INPUT RANGE ........................................................................... OVERLOAD CONTINUOUS........................................... FREQUENCY RANGE....................................................

See table ±5000Adc DC to 35Hz

OUTPUT CURRENT SIGNAL ........................................................ ACCURACY (Over Temperature Range) ...................... RESPONSE (10 to 90%) ................................................ LOAD RESISTANCE (RL) .............................................. LOAD RESISTANCE RANGE ....................................... CURRENT SIGNAL @ OVERLOAD............................... PROTECTION ................................................................

4 to 20mAdc See table & Note 1 %FS (Full Scale) 10 m sec. 250 Ohms Nominal 0 to 300 Ohms 24 mAdc typ. Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... SUPPLY VOLTAGE RANGE .......................................... TRANSIENT PROTECTION ...........................................

+24Vdc Nominal 4 to 24mAdc +18 to 28Vdc ±40V (T<5mS)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE......................... -40° to +85°C STORAGE TEMPERATURE RANGE ............................ -45° to +85°C ISOLATION..................................................................... Input to output 2KV RMS 60Hz/1min. INSULATION RESISTANCE .......................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O WEIGHT ......................................................................... 14 oz. Max. FINISH ............................................................................ Blue Textured Pantone No. 294C NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. 2: Insert tool and press to release. (Recommended Tool : Screwdriver, 3/16 standard tipped)

AAC Code Ident. No. 15948

ACCURACY 1.5% 1.5% 1.5% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%

Drawing Number

Rev.

700-921

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES S444 REMOVABLE YOKE TYPE

PART NO.

INPUT CURRENT RANGE

S444-200 .....................0 TO 200 S444-225 .....................0 TO 225 S444-250 .....................0 TO 250 S444-300 .....................0 TO 300 S444-500 .....................0 TO 500

PART NO.

INPUT CURRENT RANGE

S444-750 ................................. 0 TO 750 S444-1000 ............................... 0 TO 1000 S444-1500 ............................... 0 TO 1500 S444-2000 ............................... 0 TO 2000 S444-2500 ............................... 0 TO 2500

INPUT CURRENT RANGE........................................................... See Table CURRENT OVERLOAD.................................................... Unlimited Nondestructive OUTPUT VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RESPONSE (10 TO 90%)................................................. 200 u-sec. max. OUTPUT IMPEDANCE ..................................................... 100 Ohms max. TEMPERATURE COEFFICIENT...................................... ± .05% FS/°C max. SHORT CIRCUIT DURATION.......................................... Continuous OUTPUT LOAD................................................................. 1 K-Ohms min. SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 100mA max. REVERSE POLARITY ...................................................... No damage, 10µA current drain max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -25°C to +75°C STORAGE TEMPERATURE RANGE .............................. -55°C to +85°C ISOLATION ....................................................................... Input/Output/Case (Supply & Output common) CASE MATERIAL.............................................................. GE Lexan (Molded plastic) meets UL flammability rating 94V-0 WEIGHT ............................................................................ 12 oz. max.

TERMINAL IDENTIFICATION CONNECTOR A B C D E F

OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE

BARRIER 1 2 3 4 5

NOTES: 1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16 AWG AND WIRE LUGS TO .250 IN. WIDE. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER -C AFTER PART NUMBER FOR CONNECTOR OPTION.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S444-909

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT TRANSDUCER SERIES S465 REMOVABLE YOKE TYPE PART NO. S465-150.............. S465-250.............. S465-500.............. S465-750..............

INPUT RANGE

PART NO.

INPUT RANGE

0 to 150Adc 0 to 250Adc 0 to 500Adc 0 to 750Adc

S465-1000 .............................. S465-1500 .............................. S465-2000 .............................. S465-2500 ..............................

0 to 1000Adc 0 to 1500Adc 0 to 2000Adc 0 to 2500Adc

INPUT RANGE .................................................... OVERLOAD CONTINUOUS ...................

Adc See Table Unlimited (Nondestructive Nonlatching/ Saturated Output)

OUTPUT CURRENT SIGNAL................................. ACCURACY............................................. TEMPERATURE COEFFICIENT ............ RESPONSE (10 to 90%) ......................... LOAD RESISTANCE .............................. LOAD RESISTANCE RANGE................. CURRENT SIGNAL @ OVERLOAD.......

4 to 20mAdc FS (Full Scale) ± 1% FS or ±0.2mA max. ± 0.05% FS / °C max. 200uS max. 250 Ohms Nominal 0 to 300 Ohms 30mA TYP.

POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN................................... PROTECTION .........................................

16 to 26Vdc 30mA plus I load Reverse Polarity Protected

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE. -25° to +75°C STORAGE TEMPERATURE RANGE .... -40° to +85°C ISOLATION.............................................. Input/Output/Case INSULATION RESISTANCE................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE........... 1.5KV max. (5KV max. with insulated cable) CASE ...................................................... Molded Plastic (GE Lexan) Meets UL Flammability Rating 94 WEIGHT ................................................. 18 oz. Max.

NOTE: HOUSING AND POT HOLES SEALED MAKING TRANSDUCER WATER SPRAY RESISTANT. END USER MUST COAT TERMINAL BLOCK WITH SILICONE TO PREVENT CORROSION. NOTE: TERMINAL IDENTIFICATION 1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16AWG AND WIRE LUGS TO .250 IN. WIDE. AVALIABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER C AFTER PART NUMBER FOR CONNECTOR OPTION.

Code Ident. No. 15948

BARRIER 1 2 3 4 5

CONNECTOR OUTPUT (+) A OUTPUT (RTN) B SUPPLY VOLTAGE (+) C SUPPLY VOLTAGE (RTN) D SPARE E SPARE F

AAC

Drawing Number

Rev.

700-S465-909

F

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03 .010

.XXX ±

DC CURRENT TRANSDUCER PART NUMBER S646S646- 1000 INPUT RANGE NOMINAL ..................................................................... 0 to 1000Adc Full Scale OVERLOAD................................................................................ 0 to 5000Adc VOLTAGE ................................................................................... 2500Vdc OUTPUT VOLTAGE SIGNAL .................................................................... SCALE FACTOR ........................................................................ ACCURACY................................................................................ RESPONSE TIME....................................................................... OUTPUT IMPEDANCE............................................................... LOAD .......................................................................................... SHORT CIRCUIT ........................................................................ TRANSIENT PROTECTION ......................................................

0 to +6Vdc 6mV per Amp ±2% FS (±20Adc) over temperature range 200 µ-sec. max. 15Ω Max. 50K to ∞ Protected t ≤ 1ms ±200V

POWER SUPPLY SUPPLY VOLTAGE ................................................................... +15Vdc (±0.4Vdc) with source impedance 0 to 50 Ohms POWER CONSUMPTION .......................................................... 0.5 W max. PROTECTION............................................................................. Reverse Polarity Protected TRANSIENT PROTECTION ....................................................... t ≤ 100ms +60V/-50V ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE.................................................. -30° C to +60°C STORAGE TEMPERATURE...................................................... -55°C to +85°C SHOCK........................................................................................ Operating 50g 11m-sec MIL-STD-202 Method 213 Condition A VIBRATION................................................................................. Operating 0.06 inch D.A. 10Hz to 55Hz MIL-STD-202 Method 201 HUMIDITY................................................................................... 0 to 95% RH Operating INSULATION RESISTANCE ...................................................... 500 M-Ohms @ 500Vdc DIELECTRIC STRENGTH.......................................................... 2500 DC ATTITUDE................................................................................... Performs in any position CASE MATERIAL....................................................................... Molded plastic (GE LEXAN) meets UL Flammability rating 94V-0 ENCAPSULANT ......................................................................... STYCAST 2850FT CAT 24LV WEIGHT ...................................................................................... 12 oz. max.

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+15V) SUPPLY VOLTAGE (RTN) SPARE

NOTE: 1. SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS AND INT. TOOTH LOCKWASHERS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16AWG AND WIRE LUGS TO .250 IN. WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- S646

G

AAC AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT LEVEL DETECTOR SERIES 901B PART NO.

INPUT CURRENT

901B-20 .......................0 to 20mA 901B-50 .......................0 to 50mA 901B-100 .....................0 to 100mA 901B-200 .....................0 to 200mA 901B-250 .....................0 to 250mA

PART NO.

INPUT CURRENT

901B-500 ................................. 0 to 500mA 901B-1A................................... 0 to 1A 901B-2A................................... 0 to 2A 901B-5A................................... 0 to 5A

INPUT CURRENT RANGE (Adc) ................................................. See Table TRANSIENT PROTECTION VOLTAGE OF THRU CABLE ...........................................30KV (with insulated cable) VOLTAGE TRANSIENT.................................................... 500 Volts/u-sec. CURRENT TRANSIENT ................................................... 250 Amps/u-sec. CURRENT CAPABILITY................................................... 250 Amps for 100 m-sec. OUTPUT “A” VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) LOAD ................................................................................. 5K Ω ±1% ACCURACY....................................................................... ±1% FS (±50mV) RIPPLE .............................................................................. 3% FS RMS max. RESPONSE (10 TO 90%)................................................. 50 m-sec. max. TEMPERATURE COEFFICIENT...................................... ±0.1% FS/°C max. OUTPUT “B” VOLTAGE SIGNAL ........................................................... 18Vdc @ 10mA (Above set point) <0.05Vdc (Below set point) SET POINT........................................................................ Adjustable from 70% FS to 110% FS SET POINT REPEATABILITY .......................................... ±2% FS RESPONSE TIME............................................................. 50 m-sec max. POWER SUPPLY (PS) SUPPLY VOLTAGE ......................................................... 24Vdc ±3Vdc CURRENT DRAIN............................................................. 75mA max. REVERSE POLARITY PROTECTION ............................. 10µA current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -20°C to +70°C STORAGE TEMPERATURE RANGE .............................. -55°C to +85°C INSULATION RESISTANCE ............................................ 100 K-ohms (all terminals to case) RIPPLE .............................................................................. 40mV reflected onto pass-thru line WEIGHT ............................................................................ 1.75 lbs. Max.

TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT A (+) D. OUTPUT A (RTN) E. OUTPUT B (+) * F. OUTPUT B (RTN)

Code Ident. No. 15948

* NOTE: FOR BARRIER OPTION ONLY, TERMINALS “A-E” AS SHOWN. OUTPUT A (RTN) AND OUTPUT B (RTN) ARE COMMON AT TERMINAL D.

AAC

Drawing Number

Rev.

700-901B

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT LEVEL DETECTOR SERIES S204 PART NO.

TRIP POINT

S204-100..................... 100mA S204-150..................... 150mA S204-350..................... 350mA S204-550..................... 550mA S204-1......................... 1A

PART NO.

TRIP POINT

S204-1.2 ................................. 1.2A S204-2 ..................................... 2A S204-3 .................................... 3A S204-5 .................................... 5.75A

INPUT RANGE ............................................................................. 0 to 10Amps D.C. TRIP POINT...................................................................... See Table OUTPUT RELAY CONTACT (SPST) .............................................. CONTACT RATING ......................................................... TRIP POINT ACCURACY ................................................ TRIP POINT REPEATABILITY ........................................ RESET .............................................................................. RESPONSE TIME ............................................................ ISOLATION.......................................................................

Energized at & above set point 1 Amp @ 28V and 5V RMS ±4% set point ± 2% of set point Automatic when current falls 15% below trip point 3 m-sec max. 350V RMS @ sea level

POWER SUPPLY SUPPLY VOLTAGE ......................................................... 22.8 to 30.4Vdc CURRENT DRAIN............................................................ 70mA max. REVERSE POLARITY PROTECTION ............................ 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -20°C to +70°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 INSULATION RESISTANCE............................................ 200 M-Ohms min. MIL-STD-202 Method 302 Test Condition A ALTITUDE......................................................................... Operating sea level to 100,000 ft., MIL-STD-202, Method 105, Condition A VIBRATION....................................................................... Operating 0.06 inch D.A., 10Hz to 55Hz MIL-STD-202, Method 201 SHOCK ............................................................................. Operating 50g 11m-sec MIL-STD-202, Method 213, Condition A MOISTURE RESISTANCE .............................................. MIL-STD-202, Method 106 OPERATING HUMIDITY .................................................. 0 to 95% RH ATTITUDE ........................................................................ Meets specification for any mounting position WEIGHT ........................................................................... 12 oz. max.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S204-800

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT LEVEL DETECTOR SERIES S58-800

CURRENT ACTUATION LEVELS ZERO CURRENT INPUT ......................................... CONDITION A 200mA to 10A Max. .................................................. CONDITION B

OUTPUT CONDITION A (ZERO CURRENT) ......................... 1K-Ohm max. between terminal 1 & 2 CONDITION B (ABOVE 200mA).............................. 40K-Ohm min. between terminal 1 & 2

EXCITATION VOLTAGE VOLTAGE.................................................................. 28Vdc Nominal 22.8 to 30.4 Vdc min. to max. voltage. RESPONSE .............................................................. 1 m-sec. max. ADJUSTMENTS ....................................................... None RESET FROM COND. B TO COND. A ................... Automatic when current levels falls within 0 to 200 mA. ENVIRONMENTAL TEMPERATURE RANGE ........................................ 0°C to 70°C

BARRIER BLOCK TERMINAL 6-23 TERMINAL SCREWS.

TERMINAL IDENTIFICATION 1. 2. 3.

+28Vdc EXCITATION VOLTAGE OUTPUT EXCITATION RETURN AND OUTPUT RETURN (DC COMMON)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S58-800

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 DC CURRENT LEVEL DETECTOR PART NUMBER S754-1

INPUT RANGE .................................................... 0 to +20Adc (Continuous) TRIP POINT SETTING SET POINT............................................... 625mAdc TRIP POINT REPEATABILITY ................ 5% TRIP POINT RESPONSE TIME ............ 100 m-sec. ADJUSTMENT RANGE * ........................ Field Adjustable From 500mAdc to 1Adc RESET POINT SETTING RESET ..................................................... Manual by depressing reset switch (S1) . OUTPUT RELAY (Solid State) RELAY CONTACT (SPST) ...................... CONTACT RESISTANCE........................ DIELECTRIC STRENGTH ...................... CURRENT RATING ................................ OPEN CIRCUIT VOLTAGE……………… INDICATOR..............................................

Contacts Open at and above trip point On 1.5 Ohms Max, Off 100M Ohms Min. 2.5KV RMS 60Hz 600mAdc max. 55Vdc Max. LED on at & above trip point

POWER SUPPLY SUPPLY VOLTAGE ................................ +25 to 45Vdc CURRENT DRAIN.................................... 40mA max. TRANSIENT PROTECTION.................... ±60V Peak (30sec.); ±100V Peak (2m sec.) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -40°C to +85°C STORAGE TEMPERATURE ................... -45°C to +85°C OPERATING HUMIDITY ........................ 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ...................... 2.5Kv RMS 60Hz PRIMARY CONDUCTOR VOLTAGE ..... 1000Vdc max. CASE ........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 12 oz. max.

*

FACTORY SET AT 750mA

NOTE: 1. MOLDED TERMINAL BLOCK WITH 8-32 TERMINAL SCREWS, 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 12 AWG. TORQUE 9 IN-LB MAX. 2. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S754

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

D.C. CURRENT LEVEL DETECTOR PART NUMBER S201-800

TRIP POINT (AS CURRENT DECREASES) ........................................ 1Amp DC ±0.15Amp TRIP POINT REPEATABILITY .............................................................. ±0.02 Amps, DC RESET.................................................................................................... Automatic when input current rises approximately 0.15 A above trip point CURRENT RANGE................................................................................ 0 to 100 Amps, DC OUTPUT.................................................................................................SPDT Relay Contacts CONTACT RATING ............................................................................... 1A Resistive @ 28Vdc or 5V 400Hz 200mA Inductive. 100mA Lamp. OUTPUT ISOLATION ............................................................................ 350V RMS at sea level EXCITATION .......................................................................................... 28Vdc, Nominal @ 70mA, max. RESPONSE............................................................................................ 200 m-sec max. TEMPERATURE RANGE ...................................................................... -55°C to +70°C WEIGHT ................................................................................................. 16 oz. max. (unit) 1 oz. max. (mating conn.) MOUNTING ............................................................................................ Rigid in any position DO-160 ENV. CAT. ................................................................................ A2D2/A/CJL/EXXXFSX/ABZ/AB/ZA DO-160 ENVIRONMENT

CATEGORY

TEMPERATURE HUMIDITY VIBRATION EXPLOSION WATERPROOFNESS HYDRAULIC FLUID SAND AND DUST FUNGUS RESISTANCE SALT SPRAY MAGNETIC EFFECT POWER INPUT (NORMAL OPERATING CONDITIONS ONLY) VOLTAGE SPIKES AUDIO FREQUENCY CONDUCTED SUSCEPTIBILITY ELECTROMAGNETIC COMPATIBILITY

A2D2 A CJL E X X X F S X

AAC Code Ident. No. 15948

ABZ AB Z A

Drawing Number

Rev.

700-S201-800

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 DC CURRENT LEVEL DETECTOR PART NUMBER S680

INPUT RANGE .................................................... 0 to ± 1000Adc (Continuous) OVERLOAD / TRANSIENT...................... ± 2004A RMS (1 min) ± 1635A RMS (30 min) ± 2960A Peak (5 sec.) TRIP POINT SETTING SET POINT............................................... ±3Adc (±10%) TRIP POINT DELAY (TYPICAL) ............ 350 m-sec. After input (Absolute Value) Exceeds Trip Point ADJUSTMENT RANGE ........................... Field Adjustable ±3 to ±5Adc RESET POINT SETTING RESET POINT……………………………. One Amp (Absolute Value) Below Trip Point RESET POINT DELAY (TYPICAL)……... 10 Sec. After Input (Absolute Value) Decreases Below Reset Point OUTPUT RELAY (Solid State) RELAY CONTACT (SPST) ...................... Contacts Close at and above trip point CONTACT RESISTANCE........................ On 25 Ohms Max, Off 500M Ohms Min. DIELECTRIC STRENGTH ...................... 3.3KV RMS 60Hz CURRENT LIMIT PROTECTION ............ Automatically Limits Contact Current to 370mA OPEN CIRCUIT VOLTAGE……………… 200Vdc OR Peak Max DUTY CYCLE……………………………… Number Of “Change Of State” Operations Is Unlimited. POWER SUPPLY SUPPLY VOLTAGE ................................ +25 to 45Vdc CURRENT DRAIN.................................... 25mA max. TRANSIENT PROTECTION.................... ±60V Peak (30sec.); ±100V Peak (2m sec.)

NOTE: 1. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-005.RFP (XIZ). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB. 5. YELLOW MARKING PAINTED FOR PROTOTYPE IDENTIFICATION.

Code Ident. No. 15948

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE ................... -40°C to +85°C SHOCK & VIBRATION ............................ IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ........................ 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ...................... 3.3Kv RMS 60Hz PRIMARY BAR VOLTAGE ...................... 2Kv RMS max. CASE ........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 6.5 lbs. max.

AAC

Drawing Number

Rev.

700-S680

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT LEVEL DETECTOR PART NUMBER S629-50

INPUT RANGE .................................................... OVERLOAD / TRANSIENT .....................

TRIP POINT SET POINT .............................................. HYSTERESIS ......................................... REPEATABILITY ..................................... OUTPUT RELAY CONTACT (SPST)...................... CONTACT RATING................................. RESPONSE ............................................ DIELECTRIC STRENGTH .....................

POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... PROTECTION .........................................

0 to ± 1000Adc ± 1422A RMS (1 min) ± 1375A RMS (4 min) ± 1161A RMS (30 min) ± 2168A peak (5 sec.) ± 2514A tr (18 M-sec.)

±45Adc Auto reset 5Adc ±5% below trip point ±0.5 Adc

Actuated at and above trip point 10amp @ 45Vdc 50M-sec. MAX. 4000 V RMS coil to contact 1000 V RMS between open contact

+25 to 45Vdc 75mA max. Reverse polarity protected

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE................... -40°C to +85°C SHOCK & VIBRATION ........................... IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ....................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ..................... 3.3Kv RMS 60Hz PRIMARY BAR VOLTAGE ..................... 2Kv RMS max. CASE........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 6.5 lbs. max. NOTE: 1. MOULDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-005.RFP (XIZ). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-S629

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT LEVEL DETECTOR PART NUMBER S623-50

INPUT INPUT CURRENT.................................... OVERLOAD .............................................

TRIP POINT ADJUSTABLE .......................................... HYSTERESIS........................................... OUTPUT RELAY CONTACT (SPST)...................... CONTACT RATING................................. RESPONSE ............................................ DIELECTRIC STRENGTH .....................

POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... REVERSE POLARITY PROTECTION....

NOTE: 1. MOULDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-006.RFP (XID). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLATWASHER. TORQUE MAXIMUM 18 IN-LB.

± 10 to ± 50Adc Auto reset 5 Adc ±5% below trip point

Actuated at above trip point 10amp @ 125Vdc 50M-sec. MAX. 4000 V RMS coil to contact 1000 V RMS between open contact

+25 to 45Vdc 125mA max. 10uA current drain without damage

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +70°C STORAGE TEMPERATURE................... -45°C to +85°C SHOCK & VIBRATION ........................... IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ....................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc PRIMARY BAR VOLTAGE ..................... 2Kv RMS max. DIELECTRIC STRENGTH ..................... 3.3kV RMS 60Hz ISOLATION .............................................. Input/Output/Supply and Case 200 Meg-Ω @ 500Vdc CASE........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 8 lbs. max.

AAC Code Ident. No. 15948

0 to ± 1009Adc continuous ± 2360A Transient (18 m-sec) ± 2014A Peak (5 sec) ± 1268A RMS (1 min) ± 1221A RMS (4 min) ± 1009A RMS (30 min)

Drawing Number

Rev.

700-S623

K

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

TERMINAL IDENTIFICATION

AC CURRENT TRANSDUCER MODEL 1055L 4 TO 20mA 2 WIRE LOOP OPERATION

1. OUTPUT (+) 2. OUTPUT (RTN) PART NO.

INPUT RANGE

1055L-50............... 0 to 50mA 1055L-100............. 0 to 100mA 1055L-200............. 0 to 200mA

PART NO.

INPUT RANGE

1055L-250 ............................... 0 to 250mA 1055L-500 ............................... 0 to 500mA 1055L-1A................................. 0 to 1A

INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................

Aac See Table 50 to 60 Hz 250Aac 100 Times Range For 250m-sec.

OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................

4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) ±0.25% FS (±0.05 mA RMS) 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................

15Vdc Nominal 20mA 7 to 35Vdc

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -20° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) WEIGHT .................................................. 10 oz. Max.

NOTE: MINIMUM DC SUPPLY VOLTAGE = 7V + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. .

Code Ident. No. 15948

TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.

AAC

Drawing Number

Rev.

700-1055L

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC CURRENT TRANSDUCER SERIES S383L 4 TO 20mA 2 WIRE LOOP OPERATION

TERMINAL IDENTIFICATION 1. OUTPUT (+) 2. OUTPUT (RTN)

PART NO.

INPUT RANGE

S383L-50 .............. 0 to 50mA S383L-100 ............ 0 to 100mA S383L-200 ............ 0 to 200mA

PART NO.

INPUT RANGE

S383L-250............................... 0 to 250mA S383L-500............................... 0 to 500mA S383L-1A ................................ 0 to 1A

INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................

Aac See Table 50 to 60 Hz 250Aac 100 Times Range For 250m-sec.

OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................

4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) ±0.25% FS (±0.05 mA RMS) 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................

15Vdc Nominal 20mA 7 to 35Vdc

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -40° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) CASE **.................................................... Aluminum type 1100-0 (finish black semi-gloss enamel) WEIGHT .................................................. 10 oz. Max.

NOTE: MINIMUM DC SUPPLY VOLTAGE = 7V + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. .

Code Ident. No. 15948

TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.

AAC

Drawing Number

Rev.

700-S383L-1003AM2

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC CURRENT TRANSDUCER SERIES 1002M1 MODEL NO.

INPUT CURRENT

1002M1-250mA .... 0 to 0.25 1002M1-500mA .... 0 to 0.50 1002M1-1.............. 0 to 1 1002M1-5.............. 0 to 5 1002M1-10............ 0 to 10 1002M1-20............ 0 to 20

INPUT CURRENT RANGE..................................................... FREQUENCY........................................... FREQUENCY RANGE............................. OVERLOAD ............................................. OUTPUT VOLTAGE SIGNAL.................................. ACCURACY ............................................. RESPONSE (10 to 90%).......................... RIPPLE..................................................... TEMPERATURE COEFFICIENT ............ OUTPUT IMPEDANCE............................ OUTPUT PROTECTION ......................... POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... OVER VOLTAGE PROTECTION............ REVERSE POLARITY PROTECTION....

TERMINAL IDENTIFICATION A. B. C. D. E. F.

Code Ident. No. 15948

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT SIGNAL (RTN) SPARE OUTPUT SIGNAL (+) SPARE

MODEL NO.

INPUT CURRENT

1002M1-25 .............................. 0 to 25 1002M1-50 .............................. 0 to 50 1002M1-65 .............................. 0 to 65 1002M1-100 ............................ 0 to 100 1002M1-150 ............................ 0 to 150 1002M1-200 ............................ 0 to 200 1002M1-250 ............................ 0 to 250

Aac See Table (ADDITIONAL RANGES AVALIABLE) 400 Hz (50 & 60 Hz models available) 375 TO 475 Hz 500Aac Continuously

0 to +5Vdc FS (Full Scale) ±0.5% FS (±25mA) 10 m-sec max. 10mV RMS max. ±0.005% FS /°C max. 1000Ohms ±5% Output terminals E & C will withstand ±32Vdc or short circuit continuously 28Vdc ±4Vdc 100mA max. Terminals A & B withstand ±35Vdc without damage 10uA max. current drain without damage.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -55° to +85°C STORAGE TEMPERATURE RANGE..... -55° to +125°C DIELECTRIC STRENGTH ...................... 350V RMS (all terminals to case) INSULATION RESISTANCE ................... 100 M-Ohms (all terminals to case) ALTITUDE................................................ Operating sea level to 60,000 ft. VIBRATION.............................................. Operating- 0.06 in. D.A., 10 to 55Hz (method 201 of MIL-STD-202) SHOCK..................................................... Operating 50G, 11 m-sec half sine pulse method 213, Condition A of MIL-STD-202 MOISTURE RESISTANCE ..................... Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY ......................... 0% to 95% RH ATTITUDE................................................ Unit will perform as specified when mounted in any position WEIGHT .................................................. 1.25 lbs. Max.

AAC

Drawing Number

Rev.

700-1002M1

N

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC RMS CURRENT SENSOR SERIES S402

PART NO.

INPUT CURRENT RANGE A RMS

PART NO.

S402-250mA ............... 0 TO 250mA S402-500mA ............... 0 TO 500mA S402-1......................... 0 TO 1A S402-2......................... 0 TO 2A S402-5......................... 0 TO 5A S402-10....................... 0 TO 10A

INPUT CURRENT RANGE A RMS

S402-20 ................................... 0 TO 20A S402-50 .................................. 0 TO 50A S402-100 ................................ 0 TO 100A S402-150 ................................ 0 TO 150A S402-200 ................................. 0 TO 200A S402-250 ................................. 0 TO 250A

INPUT RANGE ..................................................................... See Table FREQUENCY RANGE ............................................. 57 to 63Hz (50 & 400Hz model available) OVERLOAD .............................................................. 200A continuously OUTPUT VOLTAGE SIGNAL................................................... ACCURACY.............................................................. RESPONSE (0 to 90%) ............................................ RIPPLE ..................................................................... TEMPERATURE COEFFICIENT ............................. OUTPUT IMPEDANCE ............................................ OUTPUT PROTECTION..........................................

POWER SUPPLY SUPPLY VOLTAGE ................................................. CURRENT DRAIN.................................................... OVER VOLTAGE PROTECTION ............................ REVERSE POLARITY PROTECTION ....................

TERMINAL IDENTIFICATION A. B. C. D. E. F.

Code Ident. No. 15948

SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT (RTN) SPARE OUTPUT (+) SPARE

0 to 5Vdc FS (Full Scale) ±.5% FS (±25mV) 100 m-sec 10mV RMS max. ± .02% FS/°C max. 1000 Ohms ±5% Output terminals E & C will withstand 32Vdc or short circuit continuously

28Vdc ±4Vdc 100mA max. Terminals A & B withstand ±35Vdc without damage 10µA max current drain without damage.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................. -0°C to +70°C STORAGE TEMPERATURE RANGE ..................... -25°C to +85°C DIELECTRIC STRENGTH ....................................... 350V RMS (all terminals to case) INSULATION RESISTANCE.................................... 100M-Ohms (all terminals to case) ALTITUDE................................................................. Operating: sea level to 60,000 ft. VIBRATION............................................................... Operating: 0.06 in. D.A., 10 to 55 Hz (Method 201 of MIL-STD-202) SHOCK ..................................................................... Operating: 50g, 11 m-sec half sine pulse Method 213, Condition A of MIL-STD-202. MOISTURE RESISTANCE ...................................... Will meet Method 106 of MIL-STD-202 and Method 507.1 Proc. 1 of MIL-STD-810. OPERATING HUMIDITY .......................................... 0% to 95% RH ATTITUDE ................................................................ Unit will perform as specified when mounted in any position. WEIGHT ................................................................... 1.25 lbs. max. ADD “-P” TO MODEL NUMBER FOR SPECIAL POTTING. SENSOR IS CAPABLE OF OPERATING WHILE SUBMERGED IN TRANSFORMER OIL.

AAC

Drawing Number

Rev.

700-S402-1004

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC CURRENT TRANSDUCER SERIES C SELF - POWERED PART

INPUT

NUMBER

OVERLOAD CAPABILITY

CURRENT

CONTINUOUS

AMPS AC TRANSIENT SEC/HR

C-1........................................0 to 1A ............................... 10A ...................................... 50A C-2........................................0 to 2A ............................... 15A ...................................... 100A C-5........................................0 to 5A ............................... 15A ...................................... 250A C-10......................................0 to 10A ............................. 20A ...................................... 500A C-20......................................0 to 20A ............................. 30A ...................................... 500A INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ LINEAR OVER RANGE............................................................. OVER LOAD CAPABILITY........................................................ DIELECTRIC.............................................................................. BURDEN....................................................................................

Aac See Table 47 to 1000Hz 20% of Range Aac See Table 2KV RMS, 60Hz, 1 min. 0.5VA max.

OUTPUT CURRENT SIGNAL................................................................... ACCURACY * (60Hz)................................................................. (47 to 1000Hz).................................................... RIPPLE ...................................................................................... RESPONSE (0 to 99%) ............................................................. LOAD RESISTANCE RANGE................................................... CALIBRATION ADJUSTMENT ................................................. STABILITY PER YEAR..............................................................

0 to 1mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 0 to 11K-Ohms ±10% FS ±0.1% FS max.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................. STORAGE TEMPERATURE .................................................... ISOLATION................................................................................ INSULATION RESISTANCE..................................................... SURGE CAPABILITY ................................................................ WEIGHT ...................................................................................

-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.

* INCLUDES COMBINED WORSE CASE EFFECTS OF TEMPERATURE AND LOAD CHANGES. TERMINAL IDENTIFICATION 1. 2. 3. 4.

OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT

NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.

Code Ident. No. 15948

ADD “-E” AND OR “-F” TO PART NUMBER FOR SPECIAL OPTIONS

“-E” OUTPUT VOLTAGE OPTION ADD -E PLUS DESIRED OUTPUT VOLTAGE FROM 0 TO A MAX OF 10

“-F” CALIBRATION FREQ. OPTION ADD -F PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000

AAC

Drawing Number

Rev.

700-C

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC VOLTAGE TRANSDUCER SERIES CX 4 TO 20mA LOOP - POWERED

PART NUMBER

INPUT CURRENT

OVERLOAD CAPABILITY

AMPS AC

CONTINUOUS

TRANSIENT SEC/HR

CX-1....................................... 0 to 1A.................................. 10A............................................... 50A CX-2....................................... 0 to 2A.................................. 15A............................................... 100A CX-5....................................... 0 to 5A.................................. 15A............................................... 250A CX-10..................................... 0 to 10A................................ 20A............................................... 500A CX-20..................................... 0 to 20A................................ 30A............................................... 500A INPUT RANGE...................................................................................... FREQUENCY............................................................................ LINEAR OVER RANGE ............................................................ OVER LOAD CAPABILITY ....................................................... DIELECTRIC............................................................................. BURDEN ................................................................................... OUTPUT CURRENT SIGNAL .................................................................. ACCURACY * (60Hz)................................................................ (47 to 1000Hz .................................................... RIPPLE...................................................................................... RESPONSE (0 to 99%)............................................................. LOAD RESISTANCE ................................................................ LOAD RESISTANCE RANGE ..................................................

TERMINAL IDENTIFICATION 1. 2. 3. 4.

OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT

Aac See Table 47 to 1000Hz 20% of Range Aac See Table 2KV RMS, 60Hz, 1 min. 0.5VA max.

PROTECTION .......................................................................... CALIBRATION ADJUSTMENT ................................................ STABILITY PER YEAR .............................................................

4 to 20mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 250 Ohms Nominal 0 to 250 Ohms @ 15Vdc 0 to 1100 Ohms @ 32Vdc Reverse Polarity Protected ±10% of FS ±0.1% FS max.

POWER SUPPLY SUPPLY VOLTAGE .................................................................. CURRENT DRAIN .................................................................... SUPPLY VOLTAGE RANGE....................................................

+15Vdc Nominal 20mA 10 to 35Vdc

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ................................................ STORAGE TEMPERATURE.................................................... ISOLATION ............................................................................... INSULATION RESISTANCE .................................................... SURGE CAPABILITY................................................................ WEIGHT ...................................................................................

-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.

* INCLUDES COMBINED WORSE CASE EFFECTS OF TEMPERATURE, SUPPLY VOLTAGE AND LOAD CHANGES. NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.

Code Ident. No. 15948

ADD “-F” TO PART NUMBER PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000Hz FOR CALIBRATION FREQ. OPTION.

AAC

Drawing Number

Rev.

700-CX

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

A.C.CURRENT SENSOR SERIES 1003AM1 OUTPUT INPUT CURRENT IMPEDANCE MODEL NO. 1003AM1-2...............................0 to 2Aac ...........................................................25 1003AM1-5...............................0 to 5Aac ...........................................................10 1003AM1-10.............................0 to 10Aac ........................................................5.0 1003AM1-15.............................0 to 15Aac ........................................................4.0 1003AM1-20.............................0 to 20Aac ........................................................2.5 1003AM1-25.............................0 to 25Aac ........................................................2.2 1003AM1-30.............................0 to 30Aac ........................................................2.0 1003AM1-50.............................0 to 50Aac ........................................................1.0 1003AM1-60.............................0 to 60Aac ........................................................0.8 1003AM1-75.............................0 to 75Aac ......................................................0.75 1003AM1-100...........................0 to 100Aac ......................................................0.5 INPUT CURRENT RANGE................................................................................ FREQUENCY ......................................................................................... FREQUENCY RANGE ........................................................................... OVERLOAD............................................................................................

See Table 60Hz 57 to 63Hz 250Aac Continuous

OUTPUT VOLTAGE SIGNAL ................................................................................ 0 to 5Vdc FS (Full Scale) ACCURACY............................................................................................ ± 1% FS for 10A range and above ±2% FS for 2A & 5A ranges RIPPLE ................................................................................................... 3% FS RMS max. RESPONSE............................................................................................ 150 m-sec max. REPEATABILITY.................................................................................... ± 0.5% FS TEMPERATURE COEFFICIENT........................................................... ± 0.04% FS/ °C max. for 10A ranges & above ±0.08% FS/°C for 2A & 5A ranges OUTPUT IMPEDANCE .......................................................................... K-Ohms See Table OUTPUT SIGNAL @ OVERLOAD ....................................................... 11Vdc max. POWER SUPPLY SUPPLY VOLTAGE ............................................................................... None, self excited ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ............................................... STORAGE TEMPERATURE RANGE ................................................... ISOLATION ............................................................................................ INSULATION RESISTANCE ................................................................. WEIGHT .................................................................................................

- 20° C to 70°C - 55°C to 85°C Input/Output/Case 100 M-Ohms output to case 5 oz. max.

TERMINAL IDENTIFICATION RED LEAD: OUTPUT (+) BLACK LEAD: OUTPUT (RTN)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-1003AM1

K

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 A.C. CURRENT SENSOR SERIES 1004 INPUT PART NO.

CURRENT

OUTPUT

INPUT

IMPEDANCE

PART NO.

1004-2.......................0 TO 2 ................

25

1004-150............ 0 TO 150 ....................

0.9

10

1004-200............ 0 TO 200 ....................

0.6

1004-10.................. 0 TO 10 ................

5.0

1004-250............ 0 TO 250 ....................

0.5

1004-20...................0 TO 20 ................

2.5

1004-300............ 0 TO 300 ....................

0.5

1004-50...................0 TO 50 ................

1.0

1004-350............ 0 TO 350 ....................

0.4

1004-100...............0 TO 100 ................

0.5

1004-400............ 0 TO 400 ....................

0.3

INPUT CURRENT RANGE ...................................................................................... FREQUENCY ............................................................................ FREQUENCY RANGE .............................................................. OVERLOAD...............................................................................

Aac See Table 400Hz 375 to 475Hz 500Aac continuously

OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... RESPONSE............................................................................... RIPPLE ...................................................................................... TEMPERATURE COEFFICIENT.............................................. OUTPUT IMPEDANCE ............................................................. REPEATABILITY....................................................................... OUTPUT SIGNAL @ OVERLOAD ...........................................

0 to +5Vdc FS (Full Scale) ± 0.5% FS (±25mV) 150 m-sec max. 0.4% FS RMS ±0.04% FS/°C max. K-Ohms max. See Table ±0.1% FS 11Vdc typical

POWER SUPPLY (PS) SUPPLY VOLTAGE .................................................................

Non, Self Excited

DIELECTRIC STRENGTH........................................................ ALTITUDE ................................................................................. VIBRATION ............................................................................... SHOCK ...................................................................................... MOISTURE RESISTANCE .......................................................

Code Ident. No. 15948

OUTPUT IMPEDANCE

1004-5...................... 0 TO 5 ................

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... INSULATION RESISTANCE ....................................................

TERMINAL IDENTIFICATION A. SPARE B. SPARE C. OUTPUT (RTN) D. SPARE E. OUTPUT (+) F. CASE GROUND

CURRENT

OPERATING HUMIDITY........................................................... ATTITUDE ................................................................................. WEIGHT ....................................................................................

AAC

-55° to +85°C -60° to +100°C 100M-Ohms (Terminals A thru E to case & terminal F) 350V RMS (Terminals A thru E to case & terminal F) Operating sea level to 60,000 ft. Operating - 0.06 in D.A., 10 to 55Hz method 201 of MIL-STD-202 Operating 50g, 11m-sec half sine pulse method 213 Condition A of MIL-STD-202 Will meet method 106 of MIL-STD-202 and method 507.1 proc. 1 of MIL-STD-810 0% to 95% RH Unit will perform as specified when mounted in any position 1.25 lbs. Max.

Drawing Number

Rev.

700-1004

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 A.C. CURRENT SENSOR

°

SERIES 1005

CURRENT RANGE PART NO.

AMPS AC

OUTPUT

CURRENT

IMPEDANCE K OHMS

PART NO.

AMPS AC

K OHMS

25

1005-50..........................50 ....................

1.5

1005-5................................5 ................

10

1005-75..........................75 ....................

1.0

1005-10............................10 ................

7.0

1005-100......................100 ....................

0.7

1005-15............................15 ................

5.0

1005-150......................150 ....................

0.5

1005-20............................20 ................

3.5

1005-200......................200 ....................

0.4

1005-25............................25 ................

3.0

1005-250......................250 ....................

0.3

1005-30............................30 ................

2.5

1005-300......................300 ....................

0.25

1005-40............................40 ................

1.75

OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY...............................................................................

See Table 50 to 60Hz 200A (2 to 100A ranges) 400A (150 to 300A ranges)

REPEATABILITY....................................................................... VOLTAGE SIGNAL @ OVERLOAD ......................................... VOLTAGE SIGNAL LINEAR TO...............................................

0 to 5Vdc FS (Full Scale) ± 1% FS for 10A range and above ±2% FS for 2A and 5A ranges 100mV RMS typical 80m-sec typical See Table ±0.04% FS/°C max. ±0.08% FS/°C max. (2 & 5A units) ±0.1% FS 11Vdc max. 6Vdc (120% FS)

POWER SUPPLY (PS) SUPPLY VOLTAGE .................................................................

Non, Self Excited

RIPPLE ...................................................................................... RESPONSE (10 to 90%) ........................................................... IMPEDANCE ............................................................................. TEMPERATURE COEFFICIENT..............................................

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... ISOLATION ............................................................................... CONDUCTOR CABLE VOLTAGE............................................ CASE ........................................................................................ WEIGHT ...................................................................................

5-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG AND WIRE LUGS UP TO 9/32” WIDE.

AAC Code Ident. No. 15948

IMPEDANCE

1005-2................................2 ................

INPUT CURRENT RANGE ...................................................................................... OPERATING FREQUENCY ..................................................... OVERLOAD CONTINUOUS.....................................................

TERMINALS:

OUTPUT

RANGE

-20° to +70°C -55° to +85°C Input/Output/Case 1.5KV max. (5KV with Insul. Cable) Molded Plastic Meets UL Flammability Rating 94V- 0 5 oz. max.

Drawing Number

Rev.

700-1005

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

TERMINAL IDENTIFICATION

AC CURRENT TRANSDUCER MODEL 1055 4 TO 20mA 2 WIRE LOOP OPERATION

1. OUTPUT (+) 2. OUTPUT (RTN) PART NO.

INPUT RANGE

1055-2 .................. 0 to 2Aac 1055-5 .................. 0 to 5Aac 1055-10 ................ 0 to 10Aac 1055-15 ................ 0 to 15Aac 1055-20 ................ 0 to 20Aac 1055-25 ................ 0 to 25Aac 1055-30 ................ 0 to 30Aac

PART NO.

INPUT RANGE

1055-40 .................................. 0 to 40Aac 1055-50 .................................. 0 to 50Aac 1055-75 .................................. 0 to 75Aac 1055-100 ................................ 0 to 100Aac 1055-150 ................................ 0 to 150Aac 1055-200 ................................ 0 to 200Aac 1055-250 ................................ 0 to 250Aac

INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................

Aac See Table 50 to 60 Hz 500Aac 10 Times Range For 250m-sec.

OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................

4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) 10mV RMS max. 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................

15Vdc Nominal 20mA 5 to 35Vdc

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -20° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) WEIGHT .................................................. 10 oz. Max.

NOTE: MINIMUM DC SUPPLY VOLTAGE = VX + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. Vx = 7V FOR P/N S383-2 AND S383-5 VX = 5V FOR P/N S383-10 THRU S383-250

Code Ident. No. 15948

TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.

AAC

Drawing Number

Rev.

700-1055

F

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC CURRENT TRANSDUCER SERIES S383 4 TO 20mA 2 WIRE LOOP OPERATION

TERMINAL IDENTIFICATION 1. OUTPUT (+) 2. OUTPUT (RTN)

PART NO.

INPUT RANGE

S383-2A................ 0 to 2Aac S383-3A................ 0 to 3Aac S383-5A................ 0 to 5Aac S383-10A.............. 0 to 10Aac S383-15A.............. 0 to 15Aac S383-20A.............. 0 to 20Aac S383-25A.............. 0 to 25Aac S383-30A.............. 0 to 30Aac

PART NO.

INPUT RANGE

S383-40A ................................ 0 to 40Aac S383-50A ................................ 0 to 50Aac S383-75A ................................ 0 to 75Aac S383-100A .............................. 0 to 100Aac S383-150A .............................. 0 to 150Aac S383-200A .............................. 0 to 200Aac S383-250A .............................. 0 to 250Aac

INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................

Aac See Table 50 to 60 Hz 500Aac 10 Times Range For 250m-sec.

OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................

4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) 10mV RMS max. 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................

15Vdc Nominal 20mA 5 to 35Vdc

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -40° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) CASE **.................................................... Aluminum type 1100-0 (finish black semi-gloss enamel) WEIGHT .................................................. 10 oz. Max.

NOTE: MINIMUM DC SUPPLY VOLTAGE = VX + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. Vx = 7V FOR P/N S383-2 AND S383-5 VX = 5V FOR P/N S383-10 THRU S383-250

Code Ident. No. 15948

TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.

AAC

Drawing Number

Rev.

700-S383-1003AM2

K

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC RMS CURRENT TRANSDUCER SERIES 1070 4 to 20mA 2 WIRE LOOP POWER PART CURRENT NUMBER RANGE 1070-2.......................... 0 to 2 1070-5 .......................... 0 to 5 1070-10........................ 0 to 10 1070-15………………. 0 to 15 1070-20 ........................ 0 to 20 1070-25 ........................ 0 to 25 1070-30 ........................ 0 to 30

PART CURRENT NUMBER RANGE 1070-40………………… 0 to 40 1070-50………………… 0 to 50 1070-75………………… 0 to 75 1070-100……………….. 0 to 100 1070-150 ………………. 0 to 150 1070-200……………….. 0 to 200 1070-250………………. 0 to 250

INPUT RANGE ........................................................................... OVERLOAD ................................................................... FREQUENCY RANGE....................................................

Aac rms (see table) 500Aac 20 to 2KHz

OUTPUT CURRENT SIGNAL ........................................................ ACCURACY (Over the Temperature Range).................. RIPPLE ........................................................................... RESPONSE (10 to 90%)................................................. LOAD RESISTANCE (RL) .............................................. LOAD RESISTANCE RANGE ........................................ CURRENT SIGNAL @ OVERLOAD............................... OUTPUT PROTECTION.................................................

4 to 20mAdc FS ±0.25% FS max. (± 50uA) note 1 .2% max. (40uAac) 300m-sec. 250 Ohms Nominal 0 to 300 Ohms 23mAdc typ. Reverse Polarity Protection

POWER SUPPLY SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... SUPPLY VOLTAGE RANGE ..........................................

+15Vdc 4 to 23mAdc +12 TO 32Vdc

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -40° to +85°C STORAGE TEMPERATURE RANGE............................. -55° to +125°C HUMIDITY (Operating).................................................... 0% to 95%RH MOISTURE RESISTANCE ............................................. MIL-STD-202 Method 106 (note 2) 2 RANDOM VIBRATION (Operating)................................. MIL-STD-810F, Proc.1,Cat.12, WO=.095G /Hz, Time1 hr, Fig. 514.5C-8 Overall level 12.G- RMS SHOCK ........................................................................... 50g 11m-sec. half sine pulse ISOLATION ..................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE........................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O (color light gray) WEIGHT ......................................................................... 6 oz. Max. NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. NOTE 2: Meets Specified Moisture requirements with option C & D only. TERMINAL IDENTIFICATION 1. SUPPLY (+) 2. SUPPLY (RTN) 3-9. SPARE

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-1070

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT TRANSDUCER SPLIT CORE RMS RESPONDING MAXIMUM

MODEL ACTS-20-05

RANGE 2A 5A

CONTINUOUS 80A 100A

ACTS-20-50

10A 20A 50A

80A 110A 175A

125A 150A 215A

250A 300A 400A

ACTS-20-200

100A 150A 200A

200A 300A 400A

300A 450A 500A

600A 800A 1000A

SPECIFICATIONS Output Signal Output Limit Accuracy Response Time Frequency Range Power Supply Isolation Voltage Input Ranges Sensing Aperture Case Environmental Listing

6 SEC. 125A 125A

1 SEC. 250A 250A

4-20mA, Loop-powered._True RMS__________________________ 23mA ______________________________________ .08% FS________ __________________ 600mS (to 90% step change) 10-400Hz 24VDC Nominal, 40VDC Maximum__________________________ UL listed to 1270VAC, tested to 5KV Field selectable ranges from 0-200A. Consult factory for custom ranges.______ __________________ 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -4 to 122° F (-20 to 50° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada), CE

ACTS-

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-ACTS

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT TRANSDUCER SPLIT CORE AVERAGE RESPONDING MAXIMUM

TYPE -05 (ACT-20 only)

RANGE 2A 5A

CONTINUOUS 80A 100A

-50

10A 20A 50A

80A 110A 175A

125A 150A 215A

250A 300A 400A

-200

100A 150A 200A

200A 300A 400A

300A 450A 500A

600A 800A 1000A

MODEL Output Signal Output Limit Accuracy Response Time Frequency Range Other Frequencies Power Supply Loading Isolation Voltage Input Range Sensing Aperture Case Environmental Listing

1 SEC. 200A 250A

ACT-05-(type) ACT-10-(type) ACT-20-(type) 0-5VDC 0-10VDC 4-20mA 10VDC 15VDC 40mA 1.0% FS 1.0% FS 0.5% FS 100mS 100mS 300mS 50-60Hz 50-60Hz 20-100Hz Special calibration available for any frequency from 10-400Hz Self-Powered Self-Powered 12-40VDC Loop-powered 1MΩ minimum for rated accuracy 100mΩ add 1.3% error. UL listed to 1270VAC, tested to 5KV Field selectable ranges from 0-200A. Custom ranges available, consult factory. 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -4 to 122° F (-20 to 50° C), 0-95% RH non-condensing UL 508 Industrial Control Equipment (USA & Canada), CE

AAC Code Ident. No. 15948

6 SEC. 100A 124A

Drawing Number

Rev.

700-ACT

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 A.C. CURRENT SENSOR SERIES 1006 OUTPUT MODEL NO. INPUT CURRENT IMPEDANCE

OUTPUT MODEL NO. INPUT CURRENT IMPEDANCE

1006-5.......................0 TO 5 ................

9

1006-200............ 0 TO 200 ....................

.22

1006-10...................0 TO 10 ................

4.5

1006-250............ 0 TO 250 ....................

.18

1006-20...................0 TO 20 ................

2.2

1006-300........... 0 TO 300 ....................

.22

1006-25...................0 TO 25 ................

1.7

1006-350............ 0 TO 350 ....................

.2

1006-35...................0 TO 35 ................

1.4

1006-400............ 0 TO 400 ....................

.17

1006-50...................0 TO 50 ................

.88

1006-500............ 0 TO 500 ....................

.13

1006-75...................0 TO 75 ................

.61

1006-600............ 0 TO 600 ....................

.11

1006-100...............0 TO 100 ................

.45

1006-800............ 0 TO 800 ....................

.12

1006-150...............0 TO 150 ................

.30

1006-1000........ 0 TO 1000 ....................

.10

INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ OVERLOAD CONTINUOUS.....................................................

Aac See Table 50 & 60Hz 500Aac or two X FS which ever is greater

OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... RIPPLE (RMS)........................................................................... RESPONSE (10 to 90%) ........................................................... IMPEDANCE ............................................................................. TEMPERATURE COEFFICIENT.............................................. REPEATABILITY....................................................................... VOLTAGE SIGNAL @ OVERLOAD ......................................... VOLTAGE SIGNAL LINEAR TO...............................................

0 to 5Vdc FS (Full Scale) * ± 0.5% FS 10mV RMS typical 130m-sec typical K Ohms max. See Table ±0.02% FS/°C max. ±0.1% FS 10Vdc max. 6Vdc (120% FS)

POWER SUPPLY (PS) SUPPLY VOLTAGE .................................................................

None, Self Excited

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... ISOLATION ............................................................................... CONDUCTOR CABLE VOLTAGE............................................ CASE ........................................................................................ WEIGHT ................................................................................... TERMINALS:

-20° to +70°C -55° to +85°C Input/Output/Case 1.5KV max. (5KV with Insul. Cable) Molded Plastic Meets UL Flammability Rating 94V- 0 1.2 lbs. max.

* 4 to 20mA Two Wire Output Option Available

5-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG AND WIRE LUGS UP TO 9/32” WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-1006

H

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT TRANSDUCER SERIES 1006X 4 TO 20 mA 2 WIRE OPERATION

PART NO.

INPUT CURRENT

1006X-5 ................ 5 1006X-10 .............. 10 1006X-20 .............. 20 1006X-25 .............. 25 1006X-50 .............. 50 1006X-75 .............. 75 1006X-100 ............100 1006X-150 ............150

PART NO.

INPUT CURRENT

1006X-200 ............................... 200 1006X-250 ............................... 500 1006X-300 ............................... 300 1006X-400 ............................... 400 1006X-500 ............................... 500 1006X-600 ............................... 600 1006X-800 ............................... 800 1006X-1000 .............................1000 1006X-1200 .............................1200

INPUT CURRENT RANGE..................................................... See Table FREQUENCY ........................................... 50 & 60 Hz OVERLOAD CONTINUOUS.................... 500Aac or two X FS which ever is greater to a maximum of 1750A OUTPUT VOLTAGE SIGNAL.................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%) .......................... TEMPERATURE COEFFICIENT............. LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. REPEATABILITY ..................................... CURRENT SIGNAL @ OVERLOAD ....... PROTECTION ..........................................

4 to 20mAdc FS (Full Scale) ±0.5% FS (±0.1mA) Over Temperature Range .2% FS Typical 100 m-sec max. ± 0.02% FS/°C max. 250 Ohms Nominal 0 to 1400 Ohms (See Table II) ±0.1% FS 30mA Typical Reverse Polarity Protected

POWER SUPPLY SUPPLY VOLTAGE (PS) ........................ 15Vdc Nominal CURRENT DRAIN.................................... 20mA SUPPLY VOLTAGE RANGE................... 5 to 35Vdc (See Table II) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -20° to +70°C STORAGE TEMPERATURE RANGE..... -55° to +85°C ISOLATION ............................................. Input/Output/Case CONDUCTOR CABLE VOLTAGE.......... 1.5KV max. (5KV with Insul. Cable) CASE ........................................................ Molded Plastic meets UL flammability rating 94V-0 WEIGHT .................................................. 1.2 lbs. max.

TERMINALS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32” WIDE.

RL = VX + (.02)RL VX = 5V RL = 5V + (.02)(1400) = 33Vdc Code Ident. No. 15948

TABLE II SUPPLY (PS) VS LOAD LOAD RESISTANCE (RL) SUPPLY LOAD RESISTANCE 10Vdc..................................... 0 to 250 Ohms 15Vdc..................................... 0 to 500 Ohms 20Vdc..................................... 0 to 750 Ohms 25Vdc..................................... 0 to 1000 Ohms 27Vdc..................................... 0 to 1100 Ohms 33Vdc..................................... 0 to 1400 Ohms

AAC

Drawing Number

Rev.

700700- 1006X

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC RMS CURRENT TRANSDUCER SERIES S714 PART CURRENT PART CURRENT NUMBER RANGE NUMBER RANGE S714-5 ................................. 0 to 5 S714-150............................. 0 to 150 S714-10 ............................... 0 to 10 S714-200............................. 0 to 200 S714-20 ............................... 0 to 20 S714-250............................. 0 to 250 S714-25 ............................... 0 to 25 S714-300............................. 0 to 300 S714-50 ............................... 0 to 50 S714-400............................. 0 to 400 S714-75 ............................... 0 to 75 S714-500............................. 0 to 500 S714-100 ............................. 0 to 100 S714-600............................. 0 to 600

TERMINAL IDENTIFICATION 12345-

Code Ident. No. 15948

A. B. C. D. E. F.

SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT SIGNAL (+) OUTPUT (RTN) CASE GROUND SPARE

INPUT RANGE CURRENT RANGE........................................................... See Table Aac FS (Full Scale) CURRENT OVERLOAD CONTINUOUS ......................... 500Aac or two X FS which is greater FREQUENCY RANGE...................................................... 360 TO 440 Hz (60Hz Models available) OUTPUT VOLTAGE SIGNAL........................................................... 0 to +5Vdc FS ACCURACY ..................................................................... ±0.5% FS LINEARITY........................................................................ ±0.20% FS RESPONSE TIME (10 TO 90%)....................................... 75 ms max. CREST FACTOR .............................................................. 0 to 5 OUTPUT IMPEDANCE..................................................... 10 Ohms max. OUTPUT RIPPLE ............................................................. 5mV RMS max. OUTPUT LOAD ................................................................ 10K Ohms min. SHORT CIRCUIT.............................................................. Protected TEMPERATURE COEFFICIENT ..................................... ±0.01% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... +14 TO +32Vdc TRANSIENT PROTECTION ............................................ ±60V (t<100ms) CURRENT DRAIN ............................................................ 10mA max. REVERSE POLARITY PROTECTION............................. 100µA max current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -40° to +85°C STORAGE TEMPERATURE............................................ -55° to +85°C OPERATING HUMIDITY .................................................. 0% to 95% RH MOISTURE RESISTANCE............................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE......................................................................... Operating: Sea level to 70,000 ft. RANDOM VIBRATION...................................................... Operating MIL-STD-810E Category 5, Proc. 1, 2 WO=0.012G Hz, Duration 1 hr., Figure 514.4-8 Suggested Vibration levels for high performance Aircraft 12.5 G-RMS composite DIELECTRIC STRENGTH ............................................... 350V RMS terminals 1-4 to 5 & case INSULATION RESISTANCE ............................................ 100 M-Ohms min. ATTITUDE......................................................................... Unit will perform as specified when mounted in any position. SHOCK.............................................................................. Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202. WEIGHT............................................................................ 1.5 lbs. max. MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.

AAC

Drawing Number

Rev.

700-S714-1006

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC RMS CURRENT TRANSDUCER SERIES S786 PART CURRENT NUMBER RANGE S786-5 ................................. 0 to 5 S786-10 ............................... 0 to 10 S786-20 ............................... 0 to 20 S786-25 ............................... 0 to 25 S786-50 ............................... 0 to 50 S786-75 ............................... 0 to 75 S786-100 ............................. 0 to 100 S786-150 ............................. 0 to 150

PART CURRENT NUMBER RANGE S786-200............................. 0 to 200 S786-250............................. 0 to 250 S786-300............................. 0 to 300 S786-400............................. 0 to 400 S786-500............................. 0 to 500 S786-600............................. 0 to 600 S786-800............................. 0 to 800 S786-1000........................... 0 to 1000

INPUT RANGE CURRENT RANGE........................................................... See Table Aac FS (Full Scale) CURRENT OVERLOAD CONTINUOUS ......................... 500Aac or two X FS which is greater FREQUENCY RANGE...................................................... 60 Hz (400Hz Models available) OUTPUT VOLTAGE SIGNAL........................................................... 0 to +5Vdc FS ACCURACY ..................................................................... ±0.5% FS LINEARITY........................................................................ ±0.20% FS RESPONSE TIME (10 TO 90%)....................................... 130 ms typ. CREST FACTOR .............................................................. 0 to 5 OUTPUT IMPEDANCE..................................................... 10 Ohms max. OUTPUT RIPPLE ............................................................. 10mV RMS typ. OUTPUT LOAD ................................................................ 10K Ohms min. SHORT CIRCUIT.............................................................. Protected TEMPERATURE COEFFICIENT ..................................... ±0.01% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... +14 TO +32Vdc TRANSIENT PROTECTION ............................................ ±60V (t<100ms) CURRENT DRAIN ............................................................ 10mA max. REVERSE POLARITY PROTECTION............................. 100µA max current drain without damage

TERMINAL IDENTIFICATION 12345-

SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT SIGNAL (+) OUTPUT (RTN) SPARE

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -40° to +85°C STORAGE TEMPERATURE............................................ -45° to +85°C OPERATING HUMIDITY .................................................. 0% to 95% RH DIELECTRIC STRENGTH ............................................... 1500V RMS terminals 1-5 to case INSULATION RESISTANCE ............................................ 200 M-Ohms min. CONDUCTOR CABLE VOLTAGE ................................... 1.5KV max. (5KV with insulated cable) ATTITUDE......................................................................... Unit will perform as specified when mounted in any position. CASE………………………………………………………… Molded Plastic meets UL Flammability 94V-0 WEIGHT…………………………………………………….. 1.2lbs. max. MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S786-1006

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC RMS CURRENT TRANSDUCER SERIES 1001 REMOVABLE YOKE TYPE

PART NO.

INPUT CURRENT AMPS RMS

1001-100 ..................... 0 TO 100 1001-150 ..................... 0 TO 150 1001-250 ..................... 0 TO 250 1001-500 ..................... 0 TO 500 1001-750 ..................... 0 TO 750

PART NO.

1001-1000................................ 0 TO 1000 1001-1500............................... 0 TO 1500 1001-2000............................... 0 TO 2000 1001-2500............................... 0 TO 2500 1001-3000............................... 0 TO 3000

INPUT RANGE ............................................................................. FREQUENCY ................................................................... CREST FACTORS ........................................................... OVERLOAD ...................................................................... OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE (0 TO 90%) .................................................. RIPPLE ............................................................................. TEMPERATURE COEFFICENT ...................................... OUTPUT IMPEDANCE .................................................... OUTPUT PROTECTION..................................................

POWER SUPPLY SUPPLY VOLTAGE ......................................................... CURRENT DRAIN............................................................ OVER VOLTAGE PROTECTION .................................... REVERSE POLARITY PROTECTION ............................

TERMINAL IDENTIFICATION CONNECTOR A B C D E F

OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE

BARRIER 1 2 3 4

See Table DC to 480Hz Up to 7 2x Range continuously, 10x for 10 sec.

0 to 5Vdc FS (Full Scale) ±1% FS (±50mV) 100 m-sec 25mV RMS @ 60Hz ±.05% FS/°C max. 1000 Ohms ±5% Output terminals 1 & 2 will withstand ±32Vdc or short circuit continuously

+28Vdc ±4Vdc 100mA max. ±35Vdc without damage 10µA max. current drain without damage

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -25°C to +71°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C DIELECTRIC STRENGTH ............................................... 350V RMS (all terminals to case) INSULATION RESISTANCE............................................ 100 M-ohms (all terminals to case) ALTITUDE......................................................................... Operating sea level to 60,000 ft. VIBRATION....................................................................... Operating - 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK ............................................................................. Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE .............................................. Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY .................................................. 0% to 95% RH ATTITUDE ........................................................................ Units will perform as specified when mounted in any position WEIGHT ........................................................................... 2 lbs. max.

NOTE: MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS AND .375 CENTER DISTANCES. TERMINALS ACCEPT WIRE SIZES UP TO #16 AWG. WITH LUGS TO .281 IN. WIDE. ADD –C TO PART NUMBER FOR CONNECTOR OPTION CONNECTOR TYPE MS3112E-10-6P OR EQUIV.

Code Ident. No. 15948

INPUT CURRENT AMPS RMS

AAC

Drawing Number

Rev.

700-1001

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC RMS CURRENT TRANSDUCER SERIES S461 REMOVABLE YOKE TYPE

PART NO.

INPUT CURRENT AMPS RMS

S461-100 .....................0 TO 100 S461-150 .....................0 TO 150 S461-250 .....................0 TO 250 S461-500 .....................0 TO 500 S461-750 .....................0 TO 750

PART NO.

INPUT CURRENT AMPS RMS

S461-1000 ............................... 0 TO 1000 S461-1500 ............................... 0 TO 1500 S461-2000 ............................... 0 TO 2000 S461-2500 ............................... 0 TO 2500 S461-3000 ............................... 0 TO 3000

INPUT RANGE .............................................................................. See Table FREQUENCY .................................................................... DC to 480Hz CREST FACTORS............................................................ Up to 7 OVERLOAD....................................................................... 2X range continuously, 10X for 10 sec. OUTPUT VOLTAGE SIGNAL ........................................................... 0 to 5Vdc (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RESPONSE (0 to 90%) ..................................................... 100 m-sec RIPPLE .............................................................................. 25mV RMS @ 60Hz TEMPERATURE COEFFICIENT...................................... ± .05% FS/°C max. OUTPUT IMPEDANCE ..................................................... 1000 Ohms ±5% OUTPUT PROTECTION ..................................................Output terminals 1 & 2 will withstand ±32Vdc or short circuit continuously POWER SUPPLY SUPPLY VOLTAGE ......................................................... +28Vdc ±4Vdc CURRENT DRAIN............................................................. 100mA max. OVER VOLTAGE PROTECTION..................................... ±35Vdc without damage REVERSE POLARITY PROTECTION ............................. 10µA max current drain without damage.

TERMINAL IDENTIFICATION BARRIER 1 2 3 4 5

OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE

CONNECTOR A B C D E F

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -25°C to +71°C STORAGE TEMPERATURE RANGE .............................. -55°C to +100°C DIELECTRIC STRENGTH................................................ 350V RMS (all terminals to case) INSULATION RESISTANCE ............................................ 100M-Ohms (all terminals to case) ALTITDUE ......................................................................... Operating: sea level to 60,000 ft. VIBRATION ....................................................................... Operating: 0.06 in. D.A., 10 to 55 Hz (Method 201 of MIL-STD-202) SHOCK .............................................................................. Operating: 50g, 11 m-sec half sine pulse Method 213, Condition A of MIL-STD-202. MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 and Method 507.1 Proc. 1 of MIL-STD-810. OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. CASE MATERIAL.............................................................. Molded plastic meets UL flammability rating 94V-0 WEIGHT ............................................................................ 12 oz. max.

NOTES: 1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16 AWG AND WIRE LUGS TO .250 IN. WIDE. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER -C AFTER PART NUMBER FOR CONNECTOR OPTION.

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-S461-1001

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT LEVEL CONTROLLER SERIES 870

PART NO.

RANGE AMPS AC

870-1............................ 1 870-2............................ 2 870-5............................ 5 870-10..........................10 870-15.......................... 15 870-20.......................... 20

RANGE AMPS AC

PART NO.

870-50 ...................................... 50 870-100 ................................... 100 870-150 ................................... 150 870-200 ................................... 200 870-250 ................................... 250 870-300 ................................... 300

INPUT CURRENT RANGES (FULL SCALE) .............................. See Table Above FREQUENCY.................................................................... 47 to 63Hz OVERLOAD RATING....................................................... 500A for 30 sec/hr OUTPUT RELAY CONTACT RATINGS .......................................... SPDT; Actuated at set point 10 AMPS @ 250 Vac or 24 Vdc * SET POINT ..................................................................... Adjustable 20 to 100% FS SET POINT REPEATABILITY.......................................... ±0.5% of range RESET............................................................................... Automatic when current falls 20% below set point (typical) SET POINT INDICATOR LIGHT ...................................... On when current is at or above set point (Relay energized) RESPONSE....................................................................... 500 m-sec (typical) TIME DELAY (OPTIONAL) .............................................. Adjustable 0.5 sec to 15 sec * Set point normally at approx. mid range when shipped from factory. Set point adjusted by factory to desired level upon request. Set point and time delay adjustment- turn clockwise to increase. SUPPLY (AC LINE) VOLTAGE (STANDARD) ................................................. 115 Vac (105 min. - 130 max.) (OPTIONAL) ................................................... 220 Vac (200 min. - 260 max.) FREQUENCY.................................................................... 47 thru 63 Hz BURDEN ........................................................................... 4Va max. Contact Factory for 440Vac or 400Hz operations.

TERMINAL IDENTIFICATION IDENTIFICATION 1-2 3 4-5-6

AC SUPPLY VOLTAGE CASE GROUND RELAY CONTACTS

ENVIRONMENTAL AND PHYSICAL SPECIFICATION OPERATING TEMPERATURE RANGE.......................... -20°C to +70°C ISOLATION ....................................................................... Input, Relay, Case DIELECTRIC STRENGTH................................................ 2000V RMS WEIGHT ............................................................................ 2 lbs. max.

NOTE: MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 12 AWG AND WIRE LUGS UP TO 5/16 IN. WIDE

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- 870

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 6946739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT CONTROLLER SERIES 871

PART NO.

RANGE AMPS AC

871-1............................1 871-2............................2 871-5............................ 5 871-10..........................10 871-15.......................... 15 871-20.......................... 20

RANGE AMPS AC

PART NO.

871-50 ......................................50 871-100 ................................... 100 871-150 ................................... 150 871-200 ................................... 200 871-250 ................................... 250 871-300 ................................... 300

INPUT INPUT (LOAD CURRENT) CURRENT RANGES (FULL SCALE) .............................. See Table Above FREQUENCY.................................................................... 47 to 400Hz OVERLOAD...................................................................... 250A for 100AMP FS & below 500A FOR 150 AMP FS & above OUTPUT RELAY .............................................................................. SPDT; Actuated at set point RELAY CONTACT RATINGS .......................................... 10 AMPS @ 250 Vac or 24 Vdc * SET POINT ..................................................................... Adjustable 20 to 100% FS SET POINT REPEATABILITY.......................................... ±0.5% of range RESET............................................................................... Automatic when current falls 20% below set point SET POINT INDICATOR LIGHT ...................................... On when current is at or above set point (Relay energized) RESPONSE....................................................................... 500 m-sec (typical) TIME DELAY (OPTIONAL) .............................................. Adjustable 0.5 sec to 20 sec * Set point normally at mid range when shipped from factory. User desired set point can be factory set upon request. Set point and time delay adjust - turn clockwise to increase. SUPPLY (AC LINE) VOLTAGE ........................................................................ 115 Vac (105 min. - 130 max.) or 220 Vac (200 min. - 260 max.) or 440 Vac (390 min. - 490 max.) FREQUENCY RANGE...................................................... 47 thru 400 Hz ENVIRONMENTAL AND OTHER SPECIFICATIONS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C ISOLATION ....................................................................... Input, Relay, Case DIELECTRIC STRENGTH................................................ 2000V RMS WEIGHT ............................................................................ 2 lbs. max.

TERMINAL IDENTIFICATION 1-2 3 4-5-6

AC SUPPLY VOLTAGE CASE GROUND RELAY CONTACTS

NOTE: MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 12 AWG AND WIRE LUGS UP TO 5/16 IN.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- 871

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 6946739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT CONTROLLER SERIES 882

PART NO.

CURRENT RANGE AMPS AC

882-1............................ .2 TO 1 882-2............................ .4 TO 2 882-5............................ 1 TO 5 882-10.......................... 2 TO 10 882-15.......................... 3 TO 15 882-20.......................... 4 TO 20

CURRENT RANGE AMPS AC

PART NO.

882-50...................................... 882-100.................................... 882-150.................................... 882-200.................................... 882-250.................................... 882-300....................................

10 TO 50 20 TO 100 30 TO 150 40 TO 200 50 TO 250 60 TO 300

INPUT CURRENT RANGE ........................................................... See Table FREQUENCY .................................................................... 50 to 400Hz OVERLOAD CURRENT CONTINUOUS.......................... 250 Amps or two times range, whichever is greater OVERLOAD CURRENT SURGE ..................................... 10,000 Amps for 6 cycles OUTPUT RELAY CONTACT S.P.D.T. ............................................. Actuated at and above set point SWITCH RATING.............................................................. 2 Amps @ 250Vac or 30Vdc (Resistive Load) * TRIP POINT .................................................................... Adjustable over current range TRIP POINT REPEATABILITY......................................... ±0.5% of range RESET ............................................................................... Automatic @ 20% below set point RESPONSE TIME ............................................................. 500 m-sec max. TIME DELAY (OPTIONAL) .............................................. Adjustable 0.500 m-sec to 15 sec. ** INDICATOR................................................................... LED-on at & above trip POWER SUPPLY (AC LINE) VOLTAGE ........................................................................ 115Vdc VOLTAGE RANGE ........................................................... 105 to 125Vac max. FREQUENCY .................................................................... 47 to 63 Hz BURDEN ........................................................................... 4VA typical ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -20°C to +70°C STORAGE TEMPERATURE RANGE.............................. -40°C to +85°C DIELECTRIC STRENGTH ................................................ 2000V RMS CASE MATERIAL............................................................. Molded plastic meets UL flammability rating 94V-0 WEIGHT ............................................................................ TBD

DELAY OPTION ADD “-T” TO MODEL NO. FOR THE TIME DELAY OPTION.

TERMINAL BARRIER

NOTES: * TRIP POINT SET AT MID RANGE WHEN SHIPPED. SET POINT AND DELAY ADJUSTMENTS - TURN CLOCKWISE TO INCREASE. SET POINT & DELAY ADJUSTED BY FACTORY TO DESIRED LEVELS UPON REQUEST. ** LIGHT EMITTING DIODE (LED) COLOR RED INDICATES THE ON/OFF STATUS OF THE UNIT.

5-40 SCREWS 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE LUG UP TO 9/32” WIDE.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- 882

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT OPERATED SWITCHES SPLIT CORE AAC MODEL

RANGE

ADJUSTABLE

OUTPUT

ACS-CAJ-150 ACS-OAJ-150 ACS-CNO-250 ACS-ONO-250

1.5-150A 1.5-150A 1.5-250A 1.5-250A

YES YES NO NO

NORMALLY CLOSED NORMALLY OPEN NORMALLY CLOSED NORMALLY OPEN

SPECIFICATIONS Power Supply Output Output Rating

Off State Leakage Response Time Set Point Range Hysteresis

NONE--Self-powered Magnetically Isolated Solid State Switch N.O. Version: 0.2A @ 240VAC or VDC N.C. Version: 0.2A @ 130VAC or VDC Not polarity sensitive None 0.120 Second 1.5-150A 5% of Setpoint

Overload

Model Continuous Normally Open 250A Normally Closed 150A

6 Sec 500A 400A

1 Sec 1000A 1000A

Isolation Voltage Frequency Range Sensing Aperture Case Environmental Listing

UL Listed to 1,270VAC, tested to 5,000VAC 6-100Hz 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -58 to 149° F (-50 to 65° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada); CE

HOW TO ORDER ORDE R ACSACSRANGE

ACSACSRANGE

-150 – 1.5 TO 150A

-250 – 1.5 TO 250A

OUTPUT

OUTPUT

-CAJ – ADJUSTABLE – NORMALLY CLOSED -OAJ – ADJUSTABLE – NORMALLY OPEN

-CNO – NON-ADJUSTABLE – NORMALLY CLOSED -ONO – NON-ADJUSTABLE – NORMALLY OPEN

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- ACS

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT OPERATED OPERATED SWITCHES SPLIT CORE AAC MODEL

RANGES

RANGE SELECT.

OUTPUT

ACS-CAJ-200

1.5-6A 6-40A 40-200A

YES

NORMALLY CLOSED

ACS-OAJ-200

1.5-6A 6-40A 40-200A

YES

NORMALLY OPEN

SPECIFICATIONS Power Supply Supply Output Output Rating

Response Time Set Point Range Hysteresis

NONE--Self-powered Isolated Solid State Switch 1.0A @ 240VAC (Standard Units) 15A @ 120VDC, 10A @ 240VDC (-15 Option) NO: None NC: 2.5mA 0.04 to 0.120 Second 1.5-6, 6-40 & 40-200A 5% of Setpoint

Overload (1 1) (2 2) (3 3)

Current 1-6A 6-40A 40-200A

Isolation Isola tion Voltage Frequency Range Sensing Aperture Case Environmental Listing

UL Listed to 1,270VAC, tested to 5,000VAC 6-100Hz, works on VFDs 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -58 to 149° F (-50 to 65° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada); CE

Off State Leakage

Continuous 150A 150A 210A

6 Sec 400A 500A 800A

1 Sec 600A 800A 1200A

HOW TO ORDER ACSACSRANGE -200 – 1.5 TO 6A – 6 TO 40A – 40 TO 200A RANGE SELECTABLE

OUTPUT -CAJ – NORMALLY CLOSED -OAJ – NORMALLY OPEN

YES YES

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- ACSACS- 3

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT SWITCHES SPLIT CORE SELFSELF- CALIBRATING AAC MODEL

RANGE

FUNCTION

OUTPUT

ACS-CO-150 ACS-CU-150 ACS-CB-150 ACS-OO-150 ACS-OU-150 ACS-OB-150

2.8-150A 2.8-150A 2.8-150A 2.8-150A 2.8-150A 2.8-150A

OVERLOAD UNDERLOAD OVER/UNDER OVERLOAD UNDERLOAD OVER/UNDER

NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN

SPECIFICATIONS Power Supply Output Output Rating

Off State Leakage Response Time Set Point Range Set Point

NONE--Self-powered Magnetically Isolated Solid State Switch N.O. Version: 0.2A @ 240VAC or VDC N.C. Version: 0.2A @ 130VAC or VDC Not polarity sensitive None 0.20 Seconds 2.8-150A Overload: +15% of load

Underload: -15% of load Operating Window +/- 15% of Setpoint

HOW TO ORDER ORD ER

Hysteresis

5% of Setpoint

Overload

Model ALL

Isolation Voltage Volta ge Frequency Range Sensing Aperture Case Environmental Listing

UL Listed to 1,270VAC, tested to 5,000VAC 6-100Hz 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -58 to 149° F (-50 to 65° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada); CE

Continuous 150A

6 Sec 500A

1 Sec 1000A

ACS-XX-150 (2.8A TO 150A –only) -XX

FUNCTION

OUTPUT

-CO -CU -CB

OVERLOAD UNDERLOAD OVER/UNDER

NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED

-OO -OU - OB

OVERLOAD UNDERLOAD OVER/UNDER

NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- ACSACS- SC

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC CURRENT CONTROLLER SERIES 881

CURRENT RANGE OVERLOAD MODEL NUMBER AMPS AC AMPS AC 881-12.............................2 - 12 ........................................... 250 881-50..................... .......8 - 50 .......................................... 250 881-120................... ...40 - 120 ........................................... 250 881-250................... .100 - 250 ........................................... 300 INPUT CURRENT RANGE........................................................... See Table FREQUENCY.................................................................... 50 to 400 Hz OVERLOAD CURRENT CONTINUOUS.......................... See Table OVERLOAD CURRENT SURGE ..................................... 10,000 Amps for 6 cycles OUTPUT RELAY CONTACT (S.P.D.T.) .......................................... Actuated at and above set point CONTACT RATING.......................................................... 2 Amps @ 250Vac or 3Vdc (Resistive Load) * TRIP POINT.................................................................... Adjustable over current range RESET (AUTOMATIC) ..................................................... 5% of range below trip point typical RESPONSE TIME............................................................. 200 m-sec max. ** INDICATOR................................................................... LED-on at & above trip POWER SUPPLY (AC LINE) SUPPLY VOLTAGE ........................................................ 115Vac (95 min. - 126 max.) FREQUENCY.................................................................... 47 to 63 Hz BURDEN ........................................................................... 0.9VA ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -20° to +70°C STORAGE TEMPERATURE RANGE ............................. -40° to +85°C DIELECTRIC STRENGTH................................................ 2000V RMS CASE MATERIAL............................................................. Molded plastic meets UL flammability rating 94V-0 WEIGHT ............................................................................ 6 oz. max.

NOTES: TERMINAL BARRIER 5-40 SCREWS 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE LUG UP TO 9/32” WIDE.

* TRIP POINT SET AT MID RANGE WHEN SHIPPED. TURN ADJUSTABLE TRIP POINT DIAL CLOCKWISE TO INCREASE SET POINT LEVEL. SET POINT ADJUSTED BY FACTORY TO DESIRED LEVELS UPON REQUEST. ** LIGHT EMITTING DIODE (LED) COLOR RED INDICATES THE ON/OFF STATUS OF THE UNIT.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- 881

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT CONTROLLER SERIES 880B

CURRENT RANGE OVERLOAD AMPS AC AMPS AC MODEL NUMBER NU MBER 880B-12....................... 2 – 12 .......................................... 250 880B-50................... .. 8 – 50 ......................................... 250 880B-120 ......................40 – 120 ...................................... 250 880B-250.......................100 – 250 .................................... 300 INPUT CURRENT RANGE .......................................................... FREQUENCY ................................................................... OVERLOAD CURRENT CONTINUOUS ......................... OVERLOAD CURRENT SURGE.....................................

See Table 50 to 400 Hz See Table 10,000 Amps for 6 cycles

OUTPUT SOLID STATE SWITCH (S.P.D.T.N.O.)........................... SWITCH RATING ............................................................. MINIMUM SWITCH VOLTAGE ....................................... * TRIP POINT.................................................................... RESET (AUTOMATIC)..................................................... RESPONSE TIME ............................................................ ** INDICATOR ..................................................................

Actuated at and above set point 60mA, 120V, ac or dc max. 3.5V @ 0.5mA to 4.5V @ 60mA Adjustable over current range 5% of range below trip point typical 200 m-sec max. LED-on at & above trip point

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -20° to +70°C STORAGE TEMPERATURE ........................................... -40° to +85°C DIELECTRIC .................................................................... 2000V RMS CASE MATERIAL ............................................................ Molded plastic meets UL flammability rating 94V-0 WEIGHT............................................................................ 6 oz. max.

NOTES: * TRIP POINT SET AT MID RANGE WHEN SHIPPED. TURN ADJUSTABLE TRIP POINT DIAL CLOCKWISE TO INCREASE SET POINT LEVEL. SET POINT ADJUSTED BY FACTORY TO DESIRED LEVELS UPON REQUEST. ** LIGHT EMITTING DIODE (LED) COLOR RED IS IN SERIES WITH THE SOLID STATE SWITCH INDICATES THE ON/OFF STATUS OF THE UNIT.

TERMINAL BARRIER 5-40 SCREWS 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE LUG UP TO 9/32” WIDE.

AAC Code Ident. No. 15948

Drawing Number

R ev.

700700- 880B

B

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC CURRENT LEVEL DETECTOR PART NUMBER S212S212- 850 INPUT RANGE ............................................................................. FREQUENCY ................................................................... OVERLOAD CURRENT CONTINOUSE ......................... OVERLOAD CURRENT SURGE.....................................

0 to 75Aac 400Hz ±10% 100Aac 500Aac for 6 cycles

OUTPUT RELAY CONTACT (SPDT) .............................................. Energized at & above set point CONTACT RATING.......................................................... 1 Amp Resistive @ 28V or 5V 400Hz 200mA Inductive 100mA Lamp TRIP POINT(AS CURRENT DECREASES) ................... 0.5Aac ±0.075Aac TRIP POINT REPEATABILITY........................................ ± .01Aac RESET .............................................................................. Automatic when input current rises approximately 0.1Aac above trip point RESPONSE TIME ............................................................ 200 m-sec max. OUTPUT ISOLATION....................................................... 350V RMS @ sea level POWER SUPPLY SUPPLY VOLTAGE ........................................................ 28Vdc, nominal CURRENT DRAIN ............................................................ 70mA max. REVERSE POLARITY PROTECTION ............................ 100µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -55°C to +70°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 MOUNTING ...................................................................... Rigid in any position INSULATION RESISTANCE ............................................ 200 M-Ohms min. MIL-STD-202 Method 302 Test Condition A WEIGHT............................................................................ 16 oz. max. (1 oz mating connector) CATEGORY

DO-160 ENVIRONMENT

MATE WITH PT06A-10-65 (SR) (OR EQUIVALENT)

TEMPERATURE & ALTITUDE HUMIDITY VIBRATION EXPLOSION WATERPROOFNESS HYDRAULIC FLUID SAND AND DUST FUNGUS RESISTANCE SALT SPRAY MAGNETIC EFFECT POWER INPUT (NORMAL OPERATING CONDITIONS ONLY) VOLTAGE SPIKES AUDIO FREQUENCY CONDUCTED SUSCEPTIBILITY ELECTROMAGNETIC COMPATIBILITY

AAC Code Ident. No. 15948

A2D2 A CJL E X X X F S X ABZ AB Z A

Drawing Number

Rev.

700700- S212S212- 850

J

A AC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

A.C. VOLTAGE SENSOR SERIES 108 INPUT VOLTAGE CONTINUOUS RANGE Vac OVERLOAD Vac MODEL NO. 108-50 ................................ 0 to 50..............................................................100 108-130 ................................ 0 to 130............................................................180 108-150 ................................ 0 to 150............................................................200 108-270 ................................ 0 to 270............................................................380 108-500 ................................ 0 to 500............................................................700 108-600 ................................ 0 to 600............................................................800 INPUT VOLTAGE RANGE................................................................................ FREQUENCY ........................................................................................ FREQUENCY RANGE .......................................................................... BURDEN................................................................................................ OVERLOAD Vac....................................................................................

See Table 60Hz (400Hz Model Available) * 57 to 63Hz 3mA max. See Table

OUTPUT VOLTAGE SIGNAL................................................................................ 0 to +5Vdc FS (Full Scale) 4 to 20mA Output Models Available ACCURACY........................................................................................... ±0.5% FS (±25mV) RESPONSE (0 to 90%) ......................................................................... 300 m-sec max. RIPPLE .................................................................................................. 25mV RMS max. TEMPERATURE COEFFICENT ........................................................... ±0.02% FS/°C max. REPEATABILITY ................................................................................... ± 0.1% FS OUTPUT IMPEDANCE ......................................................................... 4000 Ohms max. POWER SUPPLY SUPPLY VOLTAGE............................................................................... Self excited ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE............................................... STORAGE TEMPERATURE RANGE .................................................. INSULATION RESISTANCE................................................................. DIELECTRIC STRENGTH .................................................................... WEIGHT ................................................................................................

TERMINAL IDENTIFICATION 1. 2. 3. 4.

AC VOLTAGE INPUT AC VOLTAGE INPUT OUTPUT (+) OUTPUT (RTN)

Code Ident. No. 15948

TERMINAL SCREWS 5-40 3/8 CENTER TO CENTER WIRE SIZES TO 14 AWG WIRE LUGS TO .281 WIDE.

- 20° C to +70°C - 55°C to +85°C 200 M-Ohms (all terminals to case) 1000V RMS 10 oz. max.

* NOTE: ADD SUFFIX -400 TO MODEL NO. FOR 400Hz OPERATION.

AAC

Drawing Number

Rev.

700-108

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

A.C. VOLTAGE TRANSDUCER SERIES 108X 4 TO 20mA 2 WIRE OPERATION INPUT VOLTAGE CONTINUOUS RANGE Vac OVERLOAD Vac PART NO. 108X-50 ................................ 0 to 50..............................................................100 108X-130 ................................ 0 to 130............................................................180 108X-150 ................................ 0 to 150............................................................200 108X-270 ................................ 0 to 270............................................................380 108X-500 ................................ 0 to 500............................................................700 108X-600 ................................ 0 to 600............................................................800 INPUT VOLTAGE RANGE................................................................................ FREQUENCY ........................................................................................ FREQUENCY RANGE .......................................................................... BURDEN................................................................................................ OVERLOAD Vac....................................................................................

See Table 60Hz (400Hz Model Available) * 57 to 63Hz 3mA max. See Table

OUTPUT CURRENT SIGNAL (2 WIRE OPERATION)........................................ CURRENT SIGNAL @ OVERLOAD..................................................... ACCURACY........................................................................................... RIPPLE (RMS)....................................................................................... RESPONSE (0 to 90%) ......................................................................... TEMPERATURE COEFFICENT ........................................................... LOAD RESISTANCE (RL)..................................................................... LOAD RESISTANCE RANGE............................................................... PROTECTION .......................................................................................

4 to 20mAdc FS (Full Scale) 30mA typical ±0.5% FS (±0.1mA) 0.5% FS (±0.1mA RMS) 300 m-sec max. ±0.020% FS/°C max. 250 Ohms nominal 0 to 1100 Ohms (See Table II) Reverse Polarity Protected

POWER SUPPLY (PS) SUPPLY VOLTAGE............................................................................... 15Vdc nominal CURRENT DRAIN................................................................................. 20mA SUPPLY VOLTAGE RANGE................................................................. 10 to 35Vdc (See Table II) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE............................................... STORAGE TEMPERATURE RANGE .................................................. INSULATION RESISTANCE................................................................. DIELECTRIC STRENGTH .................................................................... WEIGHT ................................................................................................

- 20° C to +70°C - 55°C to +85°C 200 M-Ohms (all terminals to case) 1000V RMS 10 oz. max.

TERMINAL IDENTIFICATION 1. 2. 3. 4.

AC VOLTAGE INPUT AC VOLTAGE INPUT OUTPUT (+) OUTPUT (RTN)

TERMINAL SCREWS 5-40 3/8 CENTER TO CENTER WIRE SIZES TO 14 AWG WIRE LUGS TO .281 WIDE.

Code Ident. No. 15948

TABLE II SUPPLY (PS) VS LOAD RESISTANCE (RL) SUPPLY 15 Vdc 20Vdc 25Vdc 30Vdc 32Vdc

LOAD RESISTANCE 0 to 250 Ohms 0 to 500 Ohms 0 to 750 Ohms 0 to 1000 Ohms 0 to 1100 Ohms

* NOTE: ADD SUFFIX -400 TO PART NO. FOR 400Hz OPERATION.

AAC

Drawing Number

Rev.

700-108X

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

A.C. VOLTAGE SENSOR MODEL S190-108

PART NUMBER S190-108-130 S190-108-150 S190-108-270 S190-108-300 S190-108-600

INPUT VOLTAGE RANGES

MAXIMUM OVERVOLTAGE

0 to 130 Vac 0 to 150 Vac 0 to 270 Vac 0 to 300 Vac 0 to 600 Vac

180 Vac 180 Vac 380 Vac 380 Vac 700 Vac

OUTPUT VOLTAGE.............................................................................. 0 to 10Vdc AC INPUT CURRENT DRAIN............................................................... 3mA, max. OUTPUT IMPEDANCE ......................................................................... 10K-Ohms, max. FREQUENCY ........................................................................................ 47 to 63Hz OUTPUT RIPPLE .................................................................................. 3% F.S. RMS, max. ACCURACY........................................................................................... ±2% F.S. REPEATABILITY ................................................................................... ½% F.S. RESPONSE ........................................................................................... 200m-sec., max. OPERATING TEMPERATURE............................................................. 0°C to +60°C STORAGE TEMPERATURE ................................................................ -25°C to +85°C TEMPERATURE COEFFICIENT .......................................................... ± 0.05% F.S./°C WEIGHT ................................................................................................ 10 oz.

TERMINAL IDENTIFICATION 1. 2. 3. 4.

AC INPUT (HI) AC INPUT (RTN) DC OUTPUT (HI) DC OUTPUT (RTN)

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-S190-108

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC VOLTAGE TRANSDUCER SERIES V SELF - POWERED

PART

INPUT

NUMBER

VOLTAGE

TRANSIENT OVERLOAD APPLICATION

SEC/HR

V-120....................................0 to 150V ........................... 115/120V ............................. 220V V-220....................................0 to 300V ........................... 208/220/240V ...................... 375V V-440....................................0 to 500V ........................... 440/480V ............................. 650V INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ LINEAR OVER RANGE............................................................. TRANSIENT CAPABILITY ........................................................ DIELECTRIC.............................................................................. BURDEN....................................................................................

Vac See Table 47 to 1000Hz 20% of Range See Table 2KV RMS, 60Hz, 1 min. 2VA max.

OUTPUT CURRENT SIGNAL................................................................... ACCURACY * (60Hz)................................................................. (47 to 1000Hz).................................................... RIPPLE ...................................................................................... RESPONSE (0 to 99%) ............................................................. LOAD RESISTANCE RANGE................................................... CALIBRATION ADJUSTMENT ................................................. STABILITY PER YEAR..............................................................

0 to 1mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 0 to 11K-Ohms ±10% FS ±0.1% FS

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................. STORAGE TEMPERATURE .................................................... ISOLATION................................................................................ INSULATION RESISTANCE..................................................... SURGE CAPABILITY ................................................................ WEIGHT ...................................................................................

-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.

* INCLUDES COMBINED WORSE CASE EFFECTS OF TEMPERATURE AND LOAD CHANGES. TERMINAL IDENTIFICATION 1. 2. 3. 4.

OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT

NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.

ADD “-E” AND OR “-F” TO PART NUMBER FOR SPECIAL OPTIONS

“-E” OUTPUT VOLTAGE OPTION ADD -E PLUS DESIRED OUTPUT VOLTAGE FROM 0 TO A MAX OF 10

“-F” CALIBRATION FREQ. OPTION ADD -F PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-V

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC VOLTAGE TRANSDUCER SERIES VX 4 TO 20mA LOOP - POWERED

PART NUMBER

INPUT VOLTAGE

TRANSIENT OVERLOAD APPLICATION

SEC/HR

VX-120 .................................0 to 150V ........................... 115/120V ............................. 220V VX-220 .................................0 to 300V ........................... 208/220/240V ...................... 375V VX-440 .................................0 to 500V ........................... 440/480V ............................. 650V INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ LINEAR OVER RANGE............................................................. TRANSIENT CAPABILITY ........................................................ DIELECTRIC.............................................................................. BURDEN....................................................................................

Vac See Table 47 to 1000Hz 20% of Range See Table 2KV RMS, 60Hz, 1 min. 2VA max.

OUTPUT CURRENT SIGNAL................................................................... ACCURACY * (60Hz)................................................................. (47 to 1000Hz).................................................... RIPPLE ...................................................................................... RESPONSE (0 to 99%) ............................................................. LOAD RESISTANCE................................................................. LOAD RESISTANCE RANGE...................................................

4 to 20mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 250 Ohms Nominal 0 to 250 Ohms @ 15Vdc 0 to 1100 Ohms @ 32Vdc PROTECTION ........................................................................... Reverse Polarity Protected CALIBRATION ADJUSTMENT ................................................. ±10% of FS STABILITY PER YEAR.............................................................. ±0.1% FS max. POWER SUPPLY SUPPLY VOLTAGE................................................................... +15Vdc Nominal CURRENT DRAIN..................................................................... 20mA SUPPLY VOLTAGE RANGE..................................................... 10 to 35Vdc

TERMINAL IDENTIFICATION 1. 2. 3. 4.

OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT

NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................. STORAGE TEMPERATURE .................................................... ISOLATION................................................................................ INSULATION RESISTANCE..................................................... SURGE CAPABILITY ................................................................ WEIGHT ...................................................................................

-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.

ADD “-F” TO PART NUMBER PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000Hz FOR CALIBRATION FREQ. OPTION.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-VX

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC VOLTAGE TRANSDUCER PART NUMBER 101M3-150

INPUT VOLTAGE RANGE ............................................................................. FREQUENCY ................................................................... BURDEN........................................................................... OVERVOLTAGE CAPABILITY ........................................

90 to 150Vac RMS 60Hz 1 Va Typical 200 Vac max.

OUTPUT SIGNAL VOLTAGE SIGNAL (V min. to V max.) ............................. ACCURACY...................................................................... RESPONSE ...................................................................... RIPPLE ............................................................................. TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE ....................................................

0 to 5Vdc FS (Full Scale) ±0.5% FS (±25mV) Within 0.5 cycle of input frequency 1% 50mV RMS max. ± 0.08% FS/°C max. (±4mVdc /°c) 2.5 K-Ohms max.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -40° to +70°C STORAGE TEMPERATURE RANGE ............................. -55° to +100°C DIELECTRIC STRENGTH ............................................... 300 V-RMS INSULATION RESISTANCE............................................ 100 M Ohms @ 500Vdc VIBRATION....................................................................... Operating, meet or exceed Method 201A of MIL-STD-202F and Method 514.3 cat. 4 of MILSTD-810C. SHOCK ............................................................................. Operating: 50g, 11 m-sec half sine pulse (meet or exceed method 213B, Condition A of MIL-STD-202F) MOISTURE RESISTANCE .............................................. Meet or exceed Method 106 of MIL-STD-202F and Method 507.2 proc. 1 of MIL-STD-810C. OPERATING HUMIDITY .................................................. 0% to 95% RH WEIGHT ........................................................................... 20 oz. max.

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

A.C. INPUT HI A.C. INPUT LO CASE GROUND OUTPUT (RTN) OUTPUT (+)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-101M3

E

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

AC VOLTAGE TRANSDUCER SERIES 102M3 INPUT VOLTAGE RANGE V min. V max. PART NUMBER 102M3-175........................................... 90 TO 175 102M3-130........................................... 105 TO 130 102M3-225........................................... 175 TO 225

INPUT VOLTAGE RANGE ............................................................................. FREQUENCY ................................................................... BURDEN........................................................................... OVERVOLTAGE CAPABILITY ........................................

OUTPUT SIGNAL VOLTAGE SIGNAL (V min. to V max.) ............................. ACCURACY...................................................................... RESPONSE ...................................................................... RIPPLE ............................................................................. TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE ....................................................

See Table 340 to 440Hz 1 Va Typical 200 Vac max. for 175, 130 ranges 300 Vac max. for 225 range

0 to 5Vdc FS (Full Scale) ±0.5% FS (±25mV) Within 1 cycle of input frequency 50mV RMS max. ± 0.08% FS/°C max. 2.5 KOhms max.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -40° to +85°C STORAGE TEMPERATURE RANGE ............................. -55° to +100°C DIELECTRIC STRENGTH ............................................... 300 V RMS INSULATION RESISTANCE............................................ 100 MOhms @ 500Vdc VIBRATION....................................................................... Operating, meet or exceed Method 201A of MIL-STD-202F and Method 514.3 cat. 4 of MILSTD-810C. SHOCK ............................................................................. Operating: 50g, 11 m-sec half sine pulse (meet or exceed method 213B, Condition A of MIL-STD-202F) MOISTURE RESISTANCE .............................................. Meet or exceed Method 106 of MIL-STD-202F and Method 507.2 proc. 1 of MIL-STD-810C. OPERATING HUMIDITY .................................................. 0% to 95% RH WEIGHT ........................................................................... 20 oz. max.

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

A.C. INPUT HI A.C. INPUT LO CASE GROUND OUTPUT (RTN) OUTPUT (+)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-102M3

E

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03 fo

.XXX ± .010

AC VOLTAGE SENSOR MODEL 105

PRESET RANGE (VMAX TO VMIN) 390 to 490 VRMS 455 to 505 VRMS 430 to 530 VRMS

MODEL -490 -505 -530

INPUT LINE FREQUENCY...................................................

57 to 63Hz

EXCITATION .........................................................................

Self-excited

BURDEN................................................................................

1Va Typical

OUTPUT FOR PRESET RANGE .........................................

0 to 5Vdc

OUTPUT IMPEDANCE .........................................................

3K Ohms Max.

RESPONSE...........................................................................

Within 1 Cycle of Input Frequency

RIPPLE ..................................................................................

50Mv rms

SUPPRESSION VOLTAGE ACCURACY.............................

± .25% of V Min.

RANGE ACCURACY ............................................................

± 0.5% F.S. Max.

TEMPERATURE COEFFICIENT..........................................

± .08% F.S. per °C

TEMPERATURE RANGE .....................................................

-40 to +85

WEIGHT ................................................................................

20oz. Max.

* OTHER PRESET RANGES AVAILABLE

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

A.C. INPUT HI A.C. INPUT LO CASE GROUND OUTPUT RETURN OUTPUT POSITIVE

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-105

J

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC VOLTAGE TRANSDUCER SERIES S657 RANGE PART NUMBER S657-750 .................................. 0 to ± 750Vdc S657-1200 .................................. 0 to ± 1200Vdc S657-1500 .................................. 0 to ± 1500Vdc

............................... ............................... ...............................

OVERLOAD ± 1500Vdc ± 1500Vdc ± 2000Vdc

INPUT RANGE .............................................................................. See Table OVERLOAD CONTINUOUS............................................. See Table OVERLOAD TRANSIENT................................................. 6Kvdc FOR 100µ µ -sec ISOLATION ....................................................................... 5Kv RMS 60Hz FOR 1 min. BURDEN @ FULL SCALE................................................ 3mA typ. for 750V range 4mA typ. for 1200V range 3.3mA typ. for 1500V range OUTPUT CURRENT SIGNAL........................................................... 4 to 20mAdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±0.2mA max.) over temp. range POLARITY SENSING ....................................................... 4 to 20mAdc proportional to the absolute. Value of the input voltage. RESPONSE (10 to 90%) ................................................... 5m-sec. max. LOAD RESISTANCE......................................................... 250 Ohms nominal LOAD RESISTANCE RANGE .......................................... 0 to 500 Ohms CURRENT SIGNAL @ OVERLOAD ................................ 22mAdc typ. NOISE FILTERING ........................................................... 1 TO 100KHZ ISOLATION MODE REJECTION RATIO ......................... >85db @ 10KHZ POWER SUPPLY SUPPLY VOLTAGE .......................................................... +24 ± 2Vdc CURRENT DRAIN............................................................. 50mA max. TRANSIENT ...................................................................... 60Vdc 5 sec. 100Vdc 1m-sec PROTECTION................................................................... Reverse Polarity Protected ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -40°° to +65°C STORAGE TEMPERATURE ............................................ -40°° to +71°C OPERATION HUMIDITY................................................... 0 to 100% relative humidity SHOCK & VIBRATION...................................................... 20g shock, 10g @ 5-200Hz INSULATION RESISTANCE ............................................ 500M-Ohms @ 500Vdc DIELECTRIC STRENGTH................................................ 1.5Kv RMS 60Hz Continuous. CASE ................................................................................. Thermoplastics Cycolac ABS UL Flammability rating 94V-0. WEIGHT ............................................................................ 1.5 lbs. max. TERMINAL IDENTIFICATION

TERMINAL IDENTIFICATION

J2

J1 J2-A. J2-B. J2-C. J2-D. J2-E.

J1-A. SPARE J1-B. INPUT VOLTS (+/-) J1-C. INPUT VOLTS (+/-)

TRANSDUCER SUPPLIED WITH MATING CONNECTORS AND SOCKET CONTACTS.

Code Ident. No. 15948

SUPPLY VOLTS (+) OUTPUT SIGNAL (+) SUPPLY & OUTPUT (RTN) SPARE SPARE

NOTE: 1.

RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND # 8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.

AAC

Drawing Number

Rev.

700-S657

H

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC VOLTAGE LEVEL DETECTOR PART NUMBER S631-800

INPUT RANGE .................................................... 0 to + 800Vdc OVERLOAD (CONTINUOUS) ................. 1000Vdc (TRANSIENT) 2000Vdc for 25M-sec. TRIP POINT SET POINT............................................... +375Vdc HYSTERESIS ......................................... Auto reset 10Vdc ±5% below trip point REPEATABILITY...................................... ± 0.5% of 400Vdc (-25 to + 70°C) OUTPUT RELAY CONTACT (SPST) ...................... CONTACT RATING ................................. RESPONSE ............................................. DIELECTRIC STRENGTH ......................

Actuated at and above trip point 10amp @ 45Vdc 110M-sec. MAX. 4000 V RMS coil to contact 1000 V RMS between open contact

POWER SUPPLY SUPPLY VOLTAGE ................................ +25 to 45Vdc CURRENT DRAIN.................................... 50mA max. PROTECTION.......................................... Reverse polarity protected ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE ................... -40°C to +85°C SHOCK & VIBRATION ............................ IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ......................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ...................... 3.3Kv RMS 60Hz CASE ........................................................ Thermoplastics Cycolac ABS Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 1.5 lbs. max.

NOTE: 1. TERMINALS : 1 -- 2 : 6-32 SCREWS TORQUE 8 IN-LB MAX. 3 - 6 : 4-40 SCREWS TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-010.RFP (XVL). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND # 8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.

Code Ident. No. 15948

AAC

Drawing Number

Rev.

700-S631

E

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

WATT & VAR TRANSDUCER SERIES W & Q

INPUT POWER RANGE .......................................... 0 to Full Scale (FS) See Table I CURRENT RANGE .................................................. 0 to 6.5A RMS - Note (2) (Current Overload 15A Continuous 250A 1 sec/hr) (Current Burden 0.08VA @ 5A) VOLTAGE RANGE (STANDARD)........................... 85 to 140V RMS - Notes (2) & (3) (Voltage Overload 140Vac Continuous) (Voltage Burden 1.5VA @ 120V one phase, all others .04VA/phase) OPTION “B” VOLTAGE RANGE ............................ 0 to 150V RMS - Note (2) (Voltage Overload 175Vac Continuous) (Voltage Burden 0.04VA @ 120V) FREQUENCY ........................................................... 60Hz (50 & 400Hz models available) POWER FACTOR RANGE ...................................... Any (lead or lag) OUTPUT CURRENT SIGNAL.................................. 0 to ±1mAdc FS - Note (2) ACCURACY ............................................................. ±0.25% FS - Note (1) LOAD RESISTANCE................................................ 0 to 10,000 ohms - Note (2) COMPLIANCE VOLTAGE....................................... 11.5Vdc min. 12.5Vdc typical RIPPLE (Peak to Peak) ........................................... 10µA max. RESPONSE ( 0 to 99%) ........................................... 400 m-sec max. TEMPERATURE COEFFICIENT ............................. ±0.005% FS/°C LONG TERM STABILITY......................................... ±0.1% FS/year OUTPUT RANGE ADJUSTMENT ........................... ±3% FS min. - Note (2) (No zero adjustment required) OPTION “B” SUPPLY VOLTAGE........................... 120V RMS Nominal (85 to 140V RMS) SUPPLY BURDEN @ 120V ..................................... 1.5VA max. (0.8PF) SUPPLY FREQUENCY............................................ 60Hz Nominal (55 to 65Hz) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ................. -20°C to +70°C STORAGE TEMPERATURE RANGE ..................... -55°C to +75°C OPERATING HUMIDITY.......................................... 0 to 95% ISOLATION............................................................... Input/Supply/Output/Case DIELECTRIC STRENGTH ....................................... 2000V RMS SURGE CAPABILITY .............................................. IEEE Proposed SWC Test OUTPUT PROTECTION .......................................... Withstand 115Vac 5 minutes standard 1Ma output only SHEET 1 OF 2

TABLE I WATT W106 W156 W206 W256 W306

VAR Q106 Q156 Q206 Q256 Q306

FULL SCALE 500W/VAR 1000W/VAR 1000W/VAR 1500W/VAR 1500W/VAR

APPLICATION SIGNAL PHASE 3 PHASE 3 WIRE (Balanced Load and Voltage) 3 PHASE 3 WIRE (Unrestricted Load and Voltage) 3 PHASE 4 WIRE (Unrestricted Load and Balanced Voltage) 3 PHASE 4 WIRE (Unrestricted Load and Voltage)

OPTION “B”: SPECIFY OPTION “B” FOR POWER, SYSTEMS WITH ABNORMAL LINE VOLTAGE VARIATIONS. FOR EXAMPLE: W106-B1; Q106-B1; W156-B1; Q156-B1; ……. ECT.

Code Ident. No. 15948

NOTES: (1) Includes Combined Worse Case Effects Of Load Changes, Input Current, Voltage And Power Factor. (2) Contact Factory For Available Options. (3) Standard Units Do Not Require An Auxiliary Supply Voltage. (4) Molded Terminal Blocks With 8-32 Terminal Screws And 7/16 Inch Center To Center Spacing. Accepts Wire Sizes Up To No. 12 With Lugs To 3/8 Inch Wide.

AAC

Drawing Number

Rev.

700700- W & Q

E

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

WATT & VAR TRANSDUCER SERIES W & Q

TERMINAL CONNECTIONS Hook-Up Diagrams Shown Are Typical Connections For Single And Three Phase Systems In Which Potential Transformers (PT) And Current Transformers (CT) Interface Between Line And Transducer. When The Line Voltage And Current Fall Within The Transducer’s Standard Current And Voltage Range i.e. 0 To 6.5A RMS And 85 To 140V RMS, Then Connections Can Be Made Directly From The Line To The Transducer Without Using PT’s Or CT’s. When The Actual Load Voltage Is Expected To Vary Beyond The Standard Rating Of 85V To 150V RMS, Then A 120Vac Supply Is Necessary Connected To Terminals 7 & 14 As Shown Below. Under These Conditions Option “B” Should Be Specified.

SHEET 2 OF 2

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- W & Q

E

AAC AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC WATT TRANSDUCER SERIES S73 PART

FULL SCALE (FS)

CURRENT

VOLTAGE

SCALE SCALE

FACTOR NUMBER

POWER RANGE

RANGE (ac)

RANGE (ac)

Vdc/KW

S73-10-115 .......................... 0-1KW................................0-10A ...................................0-150V....................... 3.000 S73-25-115 .......................... 0-2.5KW.............................0-25A ...................................0-150V....................... 2.000 S73-50-115 .......................... 0-5KW................................0-50A ...................................0-150V....................... 1.000 S73-100-115 ........................ 0-10KW..............................0-100A .................................0-150V....................... 0.500 S73-150-115 ........................ 0-15KW..............................0-150A .................................0-150V....................... 0.333 S73-200-115 ........................ 0-20KW..............................0-200A .................................0-150V....................... 0.250 S73-300-115 ........................ 0-30KW..............................0-300A .................................0-150V....................... 0.167 S73-500-115 ........................ 0-50KW..............................0-500A .................................0-150V....................... 0.100 S73-10-230 .......................... 0-2KW................................0-10A ...................................0-300V....................... 2.500 S73-25-230 .......................... 0-5KW................................0-25A ...................................0-300V....................... 1.000 S73-50-230 .......................... 0-10KW..............................0-50A ...................................0-300V....................... 0.500 S73-100-230 ........................ 0-20KW..............................0-100A .................................0-300V....................... 0.250 S73-150-230 ........................ 0-30KW..............................0-150A .................................0-300V....................... 0.167 S73-200-230 ........................ 0-40KW..............................0-200A .................................0-300V....................... 0.125 S73-300-230 ........................ 0-60KW..............................0-300A .................................0-300V....................... 0.083 S73-500-230 ........................ 0-100KW............................0-500A .................................0-300V....................... 0.050

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5. 6. 7.

LOAD POTENTIAL (HI) LOAD POTENTIAL (LO) CASE GROUND OUTPUT (RTN) OUTPUT (+) SUPPLY VOLTAGE SUPPLY VOLTAGE

INPUT POWER RANGE....................................................................... See Table FREQUENCY............................................................................ 60Hz ±5% BURDEN ................................................................................... 1VA typical POWER FACTOR RANGE ...................................................... 1 to zero (lead or lag) OUTPUT VOLTAGE SIGNAL .................................................................. 0 to +5VdcFS (Full Scale) ACCURACY.............................................................................. ±2% FS (±100mV) RESPONSE............................................................................... 400m-sec max. RIPPLE (PEAK) ........................................................................ 2% FS max. TEMPERATURE COEFFICIENT ............................................. ±0.15% FS/°C OUTPUT IMPEDANCE............................................................. 2.5K-Ohms max. P.F. PHASE ANGLE ERROR .................................................. ±3°, max. POWER SUPPLY SUPPLY VOLTAGE ................................................................. 105 to 135Vac FREQUENCY............................................................................ 50/60/400Hz BURDEN ................................................................................... 1VA typical ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. -20° to +60°C STORAGE TEMPERATURE RANGE ..................................... -40° to +85°C DIELECTRIC STRENGTH........................................................ 1000Vac INSULATION RESISTANCE .................................................... 200M-Ohms @ 500Vdc ISOLATION ............................................................................... Input/Output/Supply WEIGHT ................................................................................... 3 lbs. Max.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- S73S73- 413

C

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC WATT TRANSDUCER SERIES 415A PART

115 Vac

CURRENT

NUMBER

KW RANGE

RANGE (Aac)

SCALE FACTOR (V/KW)

415A-10-115 ........................0-1KW................................0-10 ..................................... 5 415A-25-115 ........................0-2.5KW.............................0-25 ..................................... 2 415A-50-115 ........................0-5KW................................0-50 ..................................... 1 415A-100-115 ......................0-10KW..............................0-100 ................................... 0.5 415A-150-115 ......................0-12.5KW...........................0-150 ................................... 0.4 415A-200-115 ......................0-20KW..............................0-200 ................................... 0.25 415A-300-115 ......................0-25KW..............................0-300 ................................... 0.20 415A-500-115 ......................0-50KW..............................0-500 ................................... 0.10 230 Vac KW RANGE 415A-10-230 ........................0-2KW................................0-10 ..................................... 2.5 415A-25-230 ........................0-5KW................................0-25 ..................................... 1.0 415A-50-230 ........................0-10KW..............................0-50 ..................................... 0.5 415A-100-230 ......................0-20KW..............................0-100 ................................... 0.25 415A-150-230 ......................0-25KW..............................0-150 ................................... 0.20 415A-200-230 ......................0-40KW..............................0-200 ................................... 0.125 415A-300-230 ......................0-50KW..............................0-300 ................................... 0.10

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

LOAD POTENTIAL (HI) LOAD POTENTIAL (LO) CASE GROUND OUTPUT (RTN) OUTPUT (+)

415A-500-230 ......................0-100KW............................0-500 ................................... 0.05 INPUT INPUT POWER RANGE........................................................... See Table VOLTAGE RANGE 115Vac NOMINAL ............................................................. 80 to 150Vac 230Vac NOMINAL ............................................................. 160 to 300Vac BURDEN.................................................................................... 1Va typ. CURRENT RANGE (Aac) ......................................................... See Table FREQUENCY ............................................................................ 60Hz ±5% POWER FACTOR RANGE....................................................... 1 to zero (lead or lag) PF PHASE ANGLE ERROR ..................................................... ±3° max. OUTPUT SIGNAL OUTPUT VOLTAGE ................................................................. 0 to 5Vdc FS (Full Scale) ACCURACY............................................................................... ±2% FS RIPPLE (PEAK)......................................................................... 3% FS max. RESPONSE............................................................................... 400m-sec max. OUTPUT IMPEDANCE ............................................................. 2.5K-Ohms max. TEMPERATURE COEFFICIENT.............................................. ±0.2% FS/°C max. SCALE FACTOR (VOLTS/KW) ................................................ See Table ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. 0° to 50°C STORAGE TEMPERATURE RANGE ...................................... -55° to +85°C ISOLATION ............................................................................... Input/Output/Case DIELECTRIC STRENGTH........................................................ 1000V RMS WEIGHT .................................................................................... 1 lb. max,

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-415A

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC WATT TRANSDUCER SERIES 416A PART

FULL SCALE (FS)

CURRENT

POWER RANGE

RANGE

VOLTAGE

SCALE

FACTOR NUMBER

RANGE

Vdc/KW 416A-10-440........................ 0-4KW................................0-10A ...................................0-560V....................... 1.25 416A-25-440........................ 0-10KW..............................0-25A ...................................0-560V....................... 0.50 416A-50-440........................ 0-20KW..............................0-50A ...................................0-560V....................... 0.25 416A-100-440...................... 0-40KW..............................0-100A .................................0-560V....................... 0.125 416A-150-440...................... 0-50KW..............................0-150A .................................0-560V....................... 0.100 416A-200-440...................... 0-80KW..............................0-200A .................................0-560V....................... 0.0625 416A-300-440...................... 0-100KW............................0-300A .................................0-560V....................... 0.0500 416A-500-440...................... 0-200KW............................0-500A .................................0-560V....................... 0.0250 INPUT POWER RANGE....................................................................... CURRENT RANGE................................................................... LOAD VOLTAGE RANGE ....................................................... FREQUENCY............................................................................ BURDEN ................................................................................... POWER FACTOR RANGE ......................................................

KW See Table Aac RMS See Table 320 to 560Vac 60Hz ±5% 1VA typical 1 to zero (lead or lag)

OUTPUT VOLTAGE SIGNAL .................................................................. ACCURACY.............................................................................. RESPONSE............................................................................... RIPPLE (PEAK) ........................................................................ TEMPERATURE COEFFICIENT ............................................. OUTPUT IMPEDANCE.............................................................

0 to +5VdcFS (Full Scale) ±2% FS (±100mV) 400m-sec max. 3% FS max. ±0.2% FS/°C 2.5K-Ohms max.

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. 0° to +50°C STORAGE TEMPERATURE RANGE ..................................... -40° to +85°C DIELECTRIC STRENGTH........................................................ 1000Vac INSULATION RESISTANCE .................................................... 200M-Ohms @ 500Vdc ISOLATION ............................................................................... Input/Output/Supply WEIGHT ................................................................................... 3 lbs. Max.

TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.

LOAD POTENTIAL (HI) LOAD POTENTIAL (LO) CASE GROUND OUTPUT (RTN) OUTPUT (+)

AAC Code Ident. No. 15948

Drawing Number

Rev.

700700- 416A

A

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010 AC WATT TRANSDUCER SERIES S217S217- 413 PART

MAX AMPS

RANGE

SCALE(220Vac) NUMBER

(RMS)

KW

FACTOR

V/KW S217-10 ............................... 10.......................................0-2KW ..................................2.5 S217-25 ............................... 25.......................................0-5KW ..................................1.0 S217-50 ............................... 50.......................................0-10KW ................................0.50 S217-100 ............................. 100.....................................0-20KW ................................0.25 S217-150 ............................. 150.....................................0-25KW ................................0.20 S217-200 ............................. 200.....................................0-40KW ................................0.125 PART

MAX AMPS

RANGE

SCALE

(440Vac) NUMBER

(RMS)

KW

FACTOR

V/KW V/KW S217-10 ............................... 10.......................................0-4KW ..................................1.25 S217-25 ............................... 25.......................................0-10KW ................................0.50 S217-50 ............................... 50.......................................0-20KW ................................0.25 S217-100 ............................. 100.....................................0-40KW ................................0.125 S217-150 ............................. 150.....................................0-50KW ................................0.100 S217-200 ............................. 200.....................................0-80KW ................................0.0625 INPUT POWER RANGE....................................................................... KW See Table CURRENT RANGE................................................................... Aac RMS See Table NOMINAL INPUT VOLTAGE ................................................... User selects 220Vac to 440Vac LOAD VOLTAGE RANGE ....................................................... 220Vac Nominal 160 to 300Vac 440Vac Nominal 320 to 480Vac FREQUENCY............................................................................ 57 TO 63Hz BURDEN ................................................................................... 1VA typical POWER FACTOR RANGE ...................................................... 1 to zero (lead or lag)

TERMINAL IDENTIFICATION 1. LOAD POTENTIAL (HI) (440Vac OPERATION ONLY) 2. LOAD POTENTIAL (HI) (220Vac OPERATION ONLY) 3. LOAD POTENTIAL (LO) (220 OR 440Vac OPERATION) 4. OUTPUT (RTN) 5. OUTPUT (+) 6. CASE GROUND

OUTPUT VOLTAGE SIGNAL .................................................................. ACCURACY.............................................................................. RESPONSE............................................................................... RIPPLE (PEAK) ........................................................................ P.F. PHASE ANGLE ERROR .................................................. TEMPERATURE COEFFICIENT ............................................. OUTPUT IMPEDANCE.............................................................

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. 0° to +50°C STORAGE TEMPERATURE RANGE ..................................... -40° to +85°C

AAC Code Ident. No. 15948

0 to +5VdcFS (Full Scale) ±2% FS (±100mV) 400m-sec max. 3% FS max. ±3°,max. ±0.2% FS/°C 2.5K-Ohms max.

Drawing Number

Rev.

700700- S217S217- 413

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

FREQUENCY TRANSDUCER SERIES S350L PART NO.

RANGE (Hz F.S.)

S350L-100................... 100 S350L-200................... 200 S350L-300................... 300 S350L-500................... 500 S350L-1K .................... 1K

PART NO.

RANGE (Hz F.S.)

S350L-2K ................................. 2K S350L-3K ................................ 3K S350L-5K ................................ 5K S350L-10K .............................. 10K S350L-20K ............................... 20K

AC INPUT FREQUENCY RANGES................................................... See Table SENSITIVITY, MINIMUM.................................................. 20mV RMS 5% to 100% F.S. (sine or sq. wave) SENSITIVITY, MAXIMUM................................................. There shall be no signal output for an input signal of 5mV RMS or less over the frequency range of D.C. to 20KHz PULSE WIDTH ................................................................. Minimum duration must equal 20% of the period of the maximum full scale input frequency. IMPEDANCE..................................................................... 5000 Ohms minimum VOLTAGE RANGE........................................................... The max. allowable input voltage is a function of input freq. and is equal to the input freq. divided by 2 (up to a max. of 50V RMS). INPUT ............................................................................... Transformer coupled may be connected either differentially or signal ended. COMMON MODE REJECTION ....................................... 60dB @ 60Hz with input connected differential. OUTPUT VOLTAGE SIGNAL........................................................... LINEARITY........................................................................ OUTPUT IMPEDANCE .................................................... RIPPLE .............................................................................

0 to 5Vdc F.S. with 5mA max. current ±0.1% of FS freq. @ 26Vdc power 1 Ohm max. <0.1% pk @ F.S. output increasing to approximately 1% pk-pk 1/10 F.S. input freq. ADJUSTMENT.................................................................. A trimpoint adjusts the gains such that a 5Vdc .......................................................................................... max. output may be established for freq. Input ½ F.S. min. LONG TERM STABILITY ................................................. ±0.2% F.S. per year RESPONSE ...................................................................... 30/F where F is the max. F.S. freq. To 63% TEMPERATURE COEFFICIENT ..................................... ±0.01%/°C of F.S. freq.

POWER SUPPLY SUPPLY VOLTAGE ......................................................... +22 to 30Vdc @ 120mA max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE........................................ -48°C to +74°C STORAGE TEMPERATURE ........................................... -55°C to +85°C ISOLATION....................................................................... Input/Output/Power/Case INSULATION RESISTANCE............................................ 100M-Ohms @ 500Vdc VIBRATION....................................................................... 6g RMS 20Hz to 2KHz ALTITUDE......................................................................... Sea Level to 80,000 ft. WEIGHT ........................................................................... 3 lbs. Max. FINISH .............................................................................. Orange paint per FED-STD-595 No. 12197 or equiv.

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S350L

D

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

FREQUENCY TRANSDUCER SERIES S343

PART NO. S343-120 S343-220

VOLTAGE RANGE 102 to 127 Vac 200 to 250 Vac

OVERLOAD

BURDEN

140 Vac max. 280 Vac max.

1.5 VA @ 120V 1.5VA @ 220V

OUTPUT VOLTAGE SIGNAL................................................................................ ACCURACY........................................................................................... RIPPLE AND NOISE (BROADBAND) .................................................. RESPONSE (0 to 99%) ......................................................................... TEMPERATURE ERROR .....................................................................

0Vdc @ 360Hz to 5Vdc @ 440Hz ±1.0% FS (±.05V) 25mV RMS; 50mV peak max. 250mS max. ±1Hz max. (-20°C to 70°C) ±1.3Hz max. (-40°C to 70°C) IMPEDANCE.......................................................................................... 100 Ohms max. RANGE ADJUSTMENT ........................................................................ ±3% F max. (±150mV) ZERO ADJUSTMENT ........................................................................... ±3% F max. (±150mV)

ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE............................................... STORAGE TEMPERATURE RANGE .................................................. VIBRATION............................................................................................ ALTITUDE.............................................................................................. DIELECTRIC STRENGTH @ SEA LEVEL........................................... INPUT/OUTPUT ISOLATION ............................................................... WEIGHT ................................................................................................ FINISH HOUSING ................................................................................. IDENTIFICATION ..................................................................................

-40°C to +70°C -55°C to +85°C 6g RMS, 20Hz to 2KHz -1000 ft. to 60,000 ft. 1200Vac, 400Hz (all pins to case except case ground pin) 50M-Ohms @ 50Vdc 28 oz. max. Orange paint per FED-STD-595 Number 12197 or equivalent. Each unit shall be identified with MFR’s P/N, MFR’s S/N and GAC P/N 90SCAE28401-*

AAC P/N

GAC P/N

S343-120

90SCAE28401-1

TERMINAL IDENTIFICATION A. AC INPUT B. AC INPUT (RTN) C. CASE GROUND D. OUTPUT SIGNAL (+) E. OUTPUT SIGNAL (RTN) F. SPARE

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-S343

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ± .010

DC CURRENT SENSOR SERIES 904B PART NO.

CURRENT RANGE

904B-L01 ....................0 TO 100uA 904B-L02 ....................0 TO 200uA 904B-L05 .................... 0 TO 500uA

PART NO.

CURRENT RANGE

904B-L1 .................................. 0 TO 1mA 904B-L2 ................................. 0 TO 2mA 904B-L5 ................................. 0 TO 5Ma

INPUT CURRENT RANGES ....................................................... See Table INPUT RESISTANCE ...................................................... 10 Ohms max. ISOLATION (Input to Output) .......................................... 500Vdc max. OUTPUT VOLTAGE SIGNAL.......................................................... 0 to +5.0Vdc FS (Full Scale) ACCURACY..................................................................... ±1% FS RIPPLE............................................................................ 2% FS RMS IMPEDANCE ................................................................... 1000 Ohms ±5% RESPONSE (10 to 90%) ................................................. 50 m-sec. max. TEMPERATURE COEFFICIENT..................................... ±0.04% FS/°C POWER SUPPLY SUPPLY VOLTAGE ........................................................ +28Vdc ±4Vdc CURRENT DRAIN ........................................................... 50mAdc max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -60°C to +100°C INSULATION RESISTANCE ........................................... 100 M-ohms (all terminals to case) DIELECTRIC STRENGTH............................................... 350V RMS (all terminals to case) ALTITUDE ....................................................................... Operating sea level to 60,000 ft. VIBRATION ..................................................................... Operating - 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK ............................................................................ Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE.............................................. Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY ................................................. 0% to 95% RH ATTITUDE ....................................................................... Meets spec. for any mounting position WEIGHT .......................................................................... 1.25 lbs. Max.

TERMINAL IDENTIFICATION A. B. C. D. E. F.

SUPPLY VOLTAGE (+) SUPPLY AND OUTPUT (RTN) OUTPUT SIGNAL (+) CURRENT INPUT (+) CURRENT (RTN) CASE GROUND

AAC Code Ident. No. 15948

Drawing Number

Rev.

700-904B

G

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739


Dimensions in Inches, Tolerances: .XX ± .03

.XXX ±

A.C.CURRENT SENSOR SERIES 1003AM2-B OUTPUT INPUT CURRENT IMPEDANCE MODEL NO. 1003AM2-10-B ....................... 0 to 10Aac......................................................... 7 1003AM2-15-B ....................... 0 to 15Aac......................................................... 5 1003AM2-20-B ....................... 0 to 20Aac...................................................... 3.5 1003AM2-25-B ....................... 0 to 25Aac...................................................... 3.0 1003AM2-30-B ....................... 0 to 30Aac...................................................... 2.5 1003AM2-50-B ....................... 0 to 50Aac...................................................... 1.5 1003AM2-75-B ....................... 0 to 75Aac...................................................... 1.0 1003AM2-100-B ..................... 0 to 100Aac.................................................... 0.7 1003AM2-125-B ..................... 0 to 125Aac.................................................... 0.6 1003AM2-150-B ..................... 0 to 150Aac.................................................... 0.5 1003AM2-200-B ..................... 0 to 200Aac.................................................... 0.4 1003AM2-250-B ..................... 0 to 250Aac.................................................... 0.3 1003AM2-300-B ..................... 0 to 300Aac.................................................. 0.25 INPUT CURRENT RANGE ............................................................................. See Table FREQUENCY ...................................................................................... 57 to 63Hz OVERLOAD......................................................................................... 500Aac Continuous OUTPUT VOLTAGE SIGNAL.............................................................................. ACCURACY......................................................................................... RIPPLE................................................................................................ IMPEDANCE ....................................................................................... REPEATABILITY................................................................................. RESPONSE......................................................................................... TEMPERATURE COEFFICIENT......................................................... OUTPUT SIGNAL @ OVERLOAD .....................................................

0 to 5Vdc FS (Full Scale) ± 1% FS 3% FS RMS K Ohms See Table 0.5% FS 150 m-sec ± 0.04% FS/ °C 11Vdc max.

POWER SUPPLY SUPPLY VOLTAGE............................................................................. None, self excited ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.............................................. STORAGE TEMPERATURE RANGE ................................................. ISOLATION.......................................................................................... INSULATION RESISTANCE ............................................................... WEIGHT ..............................................................................................

TERMINAL IDENTIFICATION 1. OUTPUT SIGNAL (+) 2. OUTPUT SIGNAL (RTN)

Code Ident. No. 15948

- 20° C to 70°C - 55°C to 85°C Input/Output/Case 100 M-Ohms 1.25 lbs. max.

MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 14 AWG & WIRE LUGS UP TO 9/32 IN. WIDE.

AAC

Drawing Number

Rev.

700-1003AM2-B

E

AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.