CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
SF CATALOG
705
Current Voltage Power & Frequency Transducers
PAGE
1 OF 12
BI-DIRECTIONAL CURRENT TRANSDUCERS
Series No.
PROVIDE AN ISOLATED BI-POLAR OUTPUT DIRECTLY PROPORTIONAL TO THE INPUT CURRENT. THE OUTPUT SIGNAL TRACTS THE INPUT CURRENT WAVEFORM AND RECREATES ALMOST ANY AC, DC, TRANSIENT OR COMPLEX CURRENT COMBINATION.
905B 909M4 926 929 943 944 947 948 9000 S273 S449 S630 S651 S661B S745 S764 S784
DC CURRENT TRANSDUCERS
Series No.
MONITOR DC CURRENT BY PROVIDING A MAGNETICALLY ISOLATED ANALOG OUTPUT THAT IS DIRECTLY PROPORTIONAL TO THE INPUT. LOW CURRENT RANGES ARE AVAILABLE FOR DIFFERENTIAL AND GROUND FAULT CURRENT MONITORING.
903B 904B 913A 913B 920 921 936 950 952 DCT S218 S347 S444 S465 S619 S646 S728B S767 S770
DC CURRENT DETECTORS COMPARES THE DC INPUT TO A FIXED OR ADJUSTABLE CURRENT LIMIT. THE OUTPUT IS AN ISOLATED SWITCH OR RELAY THAT ACTIVATES AS REQUIRED. DC CURRENT DETECTORS ARE SUITED FOR GROUND FAULT CURRENT MONITORING.
Series No.
AC CURRENT TRANSDUCERS
Series No.
MAINTAIN ISOLATION AND PROVIDE AN ANALOG DC OUTPUT DIRECTLY PROPORTIONAL TO AC INPUT CURRENT. TRUE-RMS AND AVERAGE RESPONDING PRODUCTS ARE AVAILABLE IN CLAMP-ON AND PASS-THRU CONFIGURATIONS.
1001 1002M1 1003AM1 1003AM2 1004 1005 1006 1006X 1055 1055L 1070 ACT ACTS C CX S383 S383L S402 S461 S714 S786
AC CURRENT DETECTORS COMPARES THE AC INPUT TO A FIXED OR ADJUSTABLE CURRENT LIMIT. THE OUTPUT IS AN ISOLATED SWITCH OR RELAY THAT IS ACTIVATED AS REQUIRED. PRODUCTS AVAILABLE IN CLAMP-ON AND PASS-THRU CONFIGURATIONS.
AC VOLTAGE TRANSDUCERS PRODUCE AN ISOLATED ANALOG OUTPUT SIGNAL DIRECTLY PROPORTIONAL TO AC VOLTAGE AT A VARIETY OF FREQUENCIES. HIGH SENSITIVITY VERSIONS ARE AVAILABLE WITH ZERO SUPPRESSED AC INPUT VOLTAGE RANGES.
DC VOLTAGE TRANSDUCER & DETECTOR SERIES S657 PRODUCES AN ISOLATED ANALOG OUTPUT PROPORTIONAL TO DC VOLTAGE. SERIES S631 COMPARES THE DC INPUT TO AN ADJUSTABLE THRESHOLD. THE OUTPUT IS AN ISOLATED RELAY THAT ACTIVATES AS REQUIRED.
AC POWER TRANSDUCERS PROVIDES AN ISOLATED ANALOG DC OUTPUT DIRECTLY PROPORTIONAL TO AC INPUT POWER. TRUE POWER (WATTS) AND VOLT-AMP-REACTIVE (VAR) TRANSDUCERS ARE AVAILABLE FOR A VARIETY OF POWER RANGES AND FREQUENCIES.
FREQUENCY TRANSDUCERS PROVIDES AN ISOLATED ANALOG DC OUTPUT SIGNAL DIRECTLY PROPORTIONAL TO AC INPUT FREQUENCY. MANY RANGES ARE AVAILABLE, STARTING AT 5 TO 100HZ AND ALL THE WAY UP TO 1K TO 20KHZ.
901B S58 S201 S204 S623 S629 S680 S754
Series No.
870 871 880B 881 882 ACS ACS-3 ACS-SC S212
Series No.
101M3 102M3 105 108 108X V VX S190
Series No.
S631 S657
Series No.
415A 416A S73 S217 W&Q
Series No.
S343 S350L
For other products including modified standard & custom specials
Visit http://www.veederline.com.au email sales@veederline.com.au or call toll-free +61 8 8347 3711
Thank you.
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
BI-DIRECTIONAL CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
2 OF12
SEVENTEEN MODELS IN ORDER OF CURRENT RANGE
SERIES
905B XData Sheet
SERIES
S661B XData Sheet
SERIES
926 XData Sheet
SERIES
S764 XData Sheet
SERIES
S273 XData Sheet
MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; RESPONSE 50m-SEC; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS.
0 TO ±100MA 0 TO ±200MA 0 TO ±250MA 0 TO ±300MA
MIL GRADE: OUTPUT 0 TO ±5V; ACCURACY 0.25%FS; POWER +24 TO 32VDC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; RESPONSE 5m-SEC; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO ±5A 0 TO ±10A 0 TO ±15A
INDUSTRIAL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER +12 TO 36VDC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; RESPONSE 1m-SEC; PLASTIC CASE; BARRIER SCREW TERMINATIONS
MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
SPACE FLIGHT; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC;
S449
FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –40° TO +71°C; APERTURE 1/4 INCH DIA; SOLDER HEADER TERMINATIONS
SERIES
S745 XData Sheet
SERIES
929 XData Sheet
SERIES
S651 XData Sheet
SPACE FLIGHT; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±12VDC; FREQUENCY DC-20KHZ; RESPONSE 1-2µ-SEC; TEMPERATURE –55° TO +100°C; APERTURE 3/8 INCH DIA; METAL CASE; WEIGHT 8OZ.; SOLDER HEADER TERMINATIONS
MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS (OVER TEMPERATURE); POWER +10VDC TO +34VDC; FREQUENCY DC-350KHZ; RESPONSE 1µSEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; CONNECTOR OR BARRIER TERMINATIONS
MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER +22 TO
+32VDC; FREQUENCY DC-3.5KHZ; RESPONSE 100µ-SEC; TEMPERATURE –40° TO +65°C; APERTURE 1+3/8 INCH DIA; CONNECTOR TERMINATIONS
0 TO ±1A 0 TO ±2A 0 TO ±5A
CURRENT RANGES 0 TO ±400MA 0 TO ±500MA 0 TO ±750MA 0 TO ±1A
MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; FREQUENCY DC TO 60HZ; RESPONSE 1m-SEC; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
SERIES
XData Sheet
CURRENT RANGES
0 TO ±50MA 0 TO ±100MA 0 TO ±200MA 0 TO ±500MA
CURRENT RANGES 0 TO ±20A 0 TO ±25A
CURRENT RANGES 0 TO ±50A 0 TO ±60A 0 TO ±70A 0 TO ±100A
0 TO ±20A 0 TO ±25A 0 TO ±30A 0 TO ±40A
CURRENT RANGES 0 TO ±200A 0 TO ±250A 0 TO ±300A 0 TO ±350A
0 TO ±25A 0 TO ±50A 0 TO ±100A 0 TO ±150A
CURRENT RANGES 0 TO ±50A 0 TO ±60A
0 TO ±25A 0 TO ±40A
CURRENT RANGES 0 TO ±150A 0 TO ±250A
0 TO ±40A 0 TO ±75A
CURRENT RANGES 0 TO ±200A 0 TO ±250A 0 TO ±300A 0 TO ±400A
0 TO ±50A 0 TO ±75A 0 TO ±100A 0 TO ±150A
CURRENT RANGES 0 TO ±200A
0 TO ±100A
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
BI-DIRECTIONAL CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
3 of 12
CONTINUED (PART TWO OF TWO)
SERIES
S784 XData Sheet
SERIES
947 XData Sheet
SERIES
943A XData Sheet
AIRCRAFT DO-160; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER +16 TO 40VDC; FREQUENCY DC-1KHZ; RESPONSE 500µ-SEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; WEIGHT 9OZ.; SOLDER HEADER TERMINATIONS
INDUSTRIAL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER
±15VDC; FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –20° TO +70°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
MIL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-100KHZ; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 1+3/8 INCH DIA; METAL CASE; BARRIER OR CONNECTOR TERMINATIONS
CURRENT RANGES 0 TO ±400A 0 TO ±500A 0 TO ±600A 0 TO ±750A
0 TO ±100A 0 TO ±200A 0 TO ±250A 0 TO ±300A
CURRENT RANGES 0 TO ±400A 0 TO ±500A 0 TO ±600A
0 TO ±100A 0 TO ±200A 0 TO ±300A
CURRENT RANGES 0 TO ±600A 0 TO ±750A 0 TO ±800A 0 TO ±1000A
0 TO ±100A 0 TO ±200A 0 TO ±300A 0 TO ±400A 0 TO ±500A
MIL GRADE: OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-20KHZ; TEMPERATURE –55° TO +85°C; APERTURE 1+3/8 INCH DIA; METAL CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS
0 TO ±600A 0 TO ±800A 0 TO ±1000A
XData Sheet
INDUSTRIAL GRADE; OUTPUT 0 TO ±5V; ACCURACY 0.5%FS; POWER ±15VDC; FREQUENCY DC-20KHZ; TEMPERATURE –20° TO +70°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO ±600A 0 TO ±800A 0 TO ±1000A
SERIES
CLAMP-ON; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC;
SERIES
944 XData Sheet
SERIES
948
909M4 XData Sheet
RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; METAL CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS
SERIES
CLAMP-ON; OUTPUT 0 TO ±5V; ACCURACY 1%FS; POWER ±15VDC;
9000
RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS
XData Sheet
SERIES
S630 XData Sheet
RAIL TRANSIT; OUTPUT 0 TO ±250MA; ACCURACY 0.5%FS; POWER +24VDC; RESPONSE 1M-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BUS-BAR AVAILABLE; BARRIER SCREW TERMINATIONS
CURRENT RANGES 0 TO ±1500A 0 TO ±2000A
CURRENT RANGES 0 TO ±1500A 0 TO ±2000A
CURRENT RANGES 0 TO ±1000A 0 TO ±1500A 0 TO ±2000A 0 TO ±2500A
0 TO ±150A 0 TO ±250A 0 TO ±500A 0 TO ±750A
CURRENT RANGES 0 TO ±1000A 0 TO ±1500A 0 TO ±2000A 0 TO ±2500A
0 TO ±150A 0 TO ±250A 0 TO ±500A 0 TO ±750A
CURRENT RANGE 0 TO ±1000A OUTPUT TO INPUT RATIO:
±250µA PER AMP
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
DC CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
4 of 12
NINETEEN MODELS IN ORDER OF CURRENT RANGE
SERIES
904B XData Sheet
SERIES
903B XData Sheet
SERIES
S767 XData Sheet
SERIES
936 XData Sheet
SERIES
S218 XData Sheet
SERIES
S619 XData Sheet
SERIES
950 XData Sheet
SERIES
913B XData Sheet
SERIES
913A XData Sheet
MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; TEMPERATURE –55° TO +85°C; INPUT VIA IN-LINE CONNECTION; RESPONSE 50m-SEC; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 50m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO +5MA 0 TO +10MA 0 TO +20MA 0 TO +50MA
DC CURRENT RANGES 0 TO +100MA 0 TO +200MA 0 TO +500MA
DC CURRENT RANGES 0 TO +200MA 0 TO +250MA 0 TO +500MA
GROUND FAULT OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 50m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 1+1/4 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 1m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/8 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO +1A 0 TO +2A 0 TO +5A
DC CURRENT RANGES 0 TO +1A 0 TO +2A 0 TO +5A
0 TO +100MA 0 TO +200MA 0 TO +500MA
SPACE FLIGHT; OUTPUT 0 TO +3.5V (ISOLATED); ACCURACY 2%FS; POWER +4.5 TO +5.5VDC; INPUT CURRENT BY IN-LINE CONNECTION; RESPONSE 1m-SEC; TEMPERATURE –55° TO +85°C; PCB MOUNT; SOLDER TERMINATIONS
MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 1m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO +1A 0 TO +2A 0 TO +5A
0 TO +10MA 0 TO +20MA 0 TO +50MA 0 TO +100MA
0 TO +10MA 0 TO +20MA 0 TO +50MA 0 TO +100MA
MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 0.5%FS; POWER +24 TO 32VDC; RESPONSE 10m-SEC; TEMPERATURE –25° TO +85°C; APERTURE 3/8 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO +1MA 0 TO +2MA 0 TO +5MA
DC CURRENT RANGES 0 TO +200MA 0 TO +250MA 0 TO +500MA 0 TO +1A
SPACE FLIGHT; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +22 TO 36VDC; RESPONSE 50m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 1/2 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
HV GROUND FAULT; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO 32VDC; RESPONSE 100m-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; CHASSIS MOUNT; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
DC CURRENT RANGES
0 TO +100µA 0 TO +200µA 0 TO +500µA
DC CURRENT RANGES 0 TO +10A
0 TO +3.5A
DC CURRENT RANGES 0 TO +40A 0 TO +50A
0 TO +10A 0 TO +20A 0 TO +30A
DC CURRENT RANGES 0 TO +30A 0 TO +50A 0 TO +35A 0 TO +75A 0 TO +40A 0 TO +100A
0 TO +10A 0 TO +15A 0 TO +20A 0 TO +25A
DC CURRENT RANGES 0 TO +40A 0 TO +50A 0 TO +75A 0 TO +100A
0 TO +10A 0 TO +20A 0 TO +25A 0 TO +30A
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
DC CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
5 of 12
CONTINUED (PART TWO OF TWO)
SERIES
S770 XData Sheet
SERIES
920 XData Sheet
SERIES
DCT XData Sheet
SERIES
S728B XData Sheet
SERIES
952 XData Sheet
INDUSTRIAL GRADE; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +12 TO 36VDC; RESPONSE 1m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; CHASSIS MOUNT; BARRIER SCREW TERMINATIONS
DC CURRENT RANGES 0 TO +60A 0 TO +70A 0 TO +100A
0 TO +20A 0 TO +25A 0 TO +30A 0 TO + 50A
CLAMP-ON; OUTPUT 4 TO +20mADC; ACCURACY 1%FS; LOOP POWER +18 TO 28VDC; RESPONSE 10m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 1.60 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO +50A 0 TO +75A
CLAMP-ON; OUTPUT 0 TO +5V OR 4 TO 20MA; ACCURACY 1%FS; POWER +20 TO 50VDC OR 22 TO 38VAC; RESPONSE 100m-SEC; OPENING 0.85 X 0.85 INCH; TEMPERATURE –20° TO +50°C; PLASTIC CASE; BARRIER SCREW TERMINATIONS
-100: 0 TO +50A, 75A OR 100A -200: 0 TO +100A, 150A OR 200A -300: 0 TO +150A, 225A OR 300A -400: 0 TO +200A, 300A OR 400A
SPACE FLIGHT; OUTPUT 0 TO +5V; ACCURACY 0.3% TO 0.5%FS; POWER
+24 TO 32VDC; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 1/2 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER HEADER TERMINATIONS
MIL GRADE; OUTPUT 0 TO +5V; ACCURACY 0.3% TO 0.5%FS; POWER +24 TO 32VDC; RESPONSE 1µ-SEC; TEMPERATURE –55° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; CHASSIS MOUNT; SOLDER HEADER TERMINATIONS
DC CURRENT RANGES 0 TO +100A 0 TO +125A
DC CURRENT RANGES
DC CURRENT RANGES 0 TO +250A 0 TO +300A 0 TO +400A
0 TO +50A 0 TO +100A 0 TO +150A 0 TO +200A
0 TO +50A 0 TO +100A 0 TO +150A 0 TO +200A
DC CURRENT RANGES 0 TO +250A 0 TO +500A 0 TO +300A 0 TO +600A 0 TO +400A 0 TO +750A
CONNECTOR TERMINATIONS
0 TO +100A 0 TO +150A 0 TO +200A 0 TO +250A
DC CURRENT RANGES 0 TO +300A 0 TO +1500A 0 TO +500A 0 TO +2000A 0 TO +750A 0 TO +2500A 0 TO +1000A 0 TO +5000A
XData Sheet
CLAMP-ON; OUTPUT 4 TO +20mADC; ACCURACY 1%FS; LOOP POWER +18 TO 28VDC; RESPONSE 10m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 1.60 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO +200A 0 TO +250A 0 TO +300A
DC CURRENT RANGES 0 TO +400A 0 TO +1000A 0 TO +500A 0 TO +1500A 0 TO +750A 0 TO +2000A
SERIES
CLAMP-ON; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO
SERIES
S347 XData Sheet
SERIES
921
S444 XData Sheet
SERIES
S465 XData Sheet
CLAMP-ON; OUTPUT 0 TO +5V; ACCURACY 1%FS; POWER +24 TO
32VDC; RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; METAL CASE; BARRIER SCREW OR
32VDC; RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS
0 TO +200A 0 TO +225A 0 TO +250A 0 TO +300A
RAIL TRANSIT CLAMP-ON; OUTPUT 4 TO 20MA; ACCURACY 1%FS; POWER
+16 TO 26VDC; RESPONSE 200µ-SEC; TEMPERATURE –25° TO +75°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW OR CONNECTOR TERMINATIONS
SERIES
RAIL TRANSIT CLAMP-ON; OUTPUT 0 TO +6V; ACCURACY 2%FS; POWER
S646
+15VDC; RESPONSE 200µ-SEC; TEMPERATURE –30° TO +60°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
XData Sheet
DC CURRENT RANGES 0 TO +500A 0 TO +1500A 0 TO +750A 0 TO +2000A 0 TO +1000A 0 TO +2500A
DC CURRENT RANGES 0 TO +1000A 0 TO +1500A 0 TO +2000A 0 TO +2500A
0 TO +150A 0 TO +250A 0 TO +500A 0 TO +750A
DC CURRENT RANGES 0 TO +1000A
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
DC CURRENT DETECTORS
DATA SHEETS AT
www.a-a-c.com
PAGE
6 of 12
EIGHT MODELS IN ORDER OF CURRENT RANGE
SERIES
901B XData Sheet
SERIES
S204 XData Sheet
SERIES
S58 XData Sheet
SERIES
S754 XData Sheet
SERIES
S201 XData Sheet
SERIES
S680 XData Sheet
SERIES
S629 XData Sheet
SERIES
S623 XData Sheet
DC CURRENT RANGES 0 TO +500MA 0 TO +1A 0 TO +2A 0 TO +5A
GROUND FAULT; OUTPUT SOLID-STATE-SWITCH AND 0 TO 5VDC; ACCURACY 1%FS; POWER +21 TO +27VDC; RESPONSE 50M-SEC; TEMPERATURE –20° TO +70°C; APERTURE 3/4 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO +20MA 0 TO +50MA 0 TO +100MA 0 TO + 250MA
INDUSTRIAL GRADE; OUTPUT SPDT RELAY; ACCURACY 4% OF SET POINT; POWER +22.8 TO +30.4VDC; RESPONSE 3M-SEC; TEMP. –20° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO +100MA 0 TO +150MA 0 TO +350MA 0 TO +550MA
DC CURRENT RANGES 0 TO +1.2A 0 TO +2A 0 TO +3A 0 TO +5.75A
INDUSTRIAL GRADE; OUTPUT SOLID-STATE-SWITCH; AUTOMATIC RESET; POWER +22.8 TO +30.4VDC; RESPONSE 1M-SEC; TEMPERATURE 0° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
DC CURRENT RANGES 0 TO +15ADC
RAIL TRANSIT; OUTPUT SOLID-STATE-RELAY; PUSHBUTTON RESET; RESPONSE 100M-SEC; POWER +25 TO +45VDC; TEMPERATURE -40° TO +50°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
DC CURRENT RANGES 0 TO +20ADC
SWITCH TRIPS @ 60MADC ±20%
ADJUSTABLE TRIP CURRENT 500MA TO 1ADC
AIRCRAFT DO-160; OUTPUT SPST RELAY; AUTOMATIC RESET; POWER +24 TO +32VDC; RESPONSE 200M-SEC; TEMP. –55° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; CONNECTOR TERMINATIONS; DO-160 ENVIRONMENTAL REQUIREMENTS
DC CURRENT RANGES 0 TO +100ADC
RAIL TRANSIT; OUTPUT SOLID-STATE-RELAY; AUTOMATIC RESET; POWER +25 TO +45VDC; RESPONSE 1M-SEC; TEMPERATURE -25° TO +75°C; APERTURE 1+1/2 INCH DIA; AVAILABLE WITH BUS-BAR; PLASTIC CASE; BARRIER SCREW TERMINATIONS
DC CURRENT RANGES
RAIL TRANSIT; OUTPUT SPST RELAY (10A CONTACTS); AUTOMATIC RESET; RESPONSE 50M-SEC; TEMP –25° TO +75°C; POWER +25 TO +45VDC; APERTURE 1+1/2 INCH DIA; BUS-BAR AVAILABLE; PLASTIC CASE; BARRIER SCREW TERMINATIONS
DC CURRENT RANGES
RAIL TRANSIT GROUND FAULT; OUTPUT SPST RELAY; AUTOMATIC RESET; RESPONSE 50M-SEC; POWER +25 TO +45VDC; TEMP –25° TO +75°C; APERTURE 1+1/2 INCH DIA; DUAL BUS-BAR AVAILABLE; PLASTIC CASE; BARRIER SCREW TERMINATIONS
DC CURRENT RANGES
RELAY TRIPS@ +1ADC ±15%
0 to +1000Adc RELAY TRIPS@
±3Adc ±10%
0 to +1000Adc RELAY TRIPS@ ±45Adc ±0.5Adc
0 to +1600Adc RELAY TRIP ADJUSTMENT RANGE:
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
AC CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
7 OF 12
TWENTY-ONE MODELS IN ORDER OF CURRENT RANGE
SERIES
1055L XData Sheet
SERIES
S383L XData Sheet
SERIES
1002M1 XData Sheet
SERIES
S402 XData Sheet
SERIES
C XData Sheet
SERIES
CX XData Sheet
SERIES
1003AM1 XData Sheet
SERIES
1004 XData Sheet
SERIES
1005 XData Sheet
SERIES
1055 XData Sheet
INDUSTRIAL GRADE; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100mSEC; TEMP. –20° TO +85°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 50MA 0 TO 100MA 0 TO 200MA
PROCESS CONTROL; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100mSEC; TEMP. –40° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 50MA 0 TO 100MA 0 TO 200MA
AC CURRENT RANGES 0 TO 250MA 0 TO 500MA 0 TO 1A
AC CURRENT RANGES 0 TO 250MA 0 TO 500MA 0 TO 1A
MIL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; POWER +24 TO +32VDC; FREQUENCY 375-475HZ (OTHERS AVAILABLE); RESPONSE 10m-SEC; TEMPERATURE -55° TO +85°C; APERTURE 3/4 INCH DIA; SOLDER, CONNECTOR OR BARRIER SCREW TERMINATIONS
0 TO 250MA 0 TO 500MA 0 TO 1A 0 TO 5A 0 TO 10A
RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; POWER +24 TO +32VDC; FREQUENCY 57-63HZ (OTHERS AVAILABLE); RESPONSE 100m-SEC; TEMPERATURE 0° TO 70°C; APERTURE 3/4 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINALS
0 TO 250MA 0 TO 500MA 0 TO 1A 0 TO 2A 0 TO 3A
AC CURRENT RANGES 0 TO 20A 0 0 TO 25A 0 0 TO 50A 0 0 TO 65A 0
TO 100A TO 150A TO 200A TO 250A
AC CURRENT RANGES 0 TO 5A 0 0 TO 10A 0 0 TO 20A 0 0 TO 50A 0
TO 100A TO 150A TO 200A TO 250A
AVERAGE RESPONDING; OUTPUT 0 TO 1mADC; ACCURACY 0.25%FS; POWERED BY INPUT; FREQUENCY 47-1000HZ; RESPONSE 400m-SEC; TEMPERATURE -20° TO +70°C; INPUT BY IN-LINE CONNECTION; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 1A 0 TO 2A 0 TO 5A
AVERAGE RESPONDING; OUTPUT 4 TO 20MADC; ACCURACY 0.25%FS; LOOPPOWER 10 TO 35VDC; FREQUENCY 47-1000HZ; RESPONSE 400M-SEC; TEMPERATURE -20° TO +70°C; INPUT BY IN-LINE CONNECTION; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 1A 0 TO 2A 0 TO 5A
PROCESS OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY 5763HZ (OTHERS AVAILABLE); POWERED BY INPUT; RESPONSE 150m SEC; TEMPERATURE -20° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; BARRIER TERMINALS
AC CURRENT RANGES 0 TO 20A 0 0 TO 25A 0 0 TO 30A 0 0 TO 40A 0
TO 50A TO 60A TO 75A TO 100A
0 TO 2A 0 TO 5A 0 TO 7A 0 TO 10A 0 TO 15A
AC CURRENT RANGES 0 TO 10A 0 TO 20A
AC CURRENT RANGES 0 TO 10A 0 TO 20A
MIL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY 375 TO 475HZ; RESPONSE 150m-SEC; TEMPERATURE -55° TO +85°C; POWERED BY INPUT; APERTURE 3/8 OR 3/4 INCH DIA; METAL CASE; SOLDER, CONNECTOR OR BARRIER TERMINATIONS
0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A
AC CURRENT RANGES 0 TO 50A 0 0 TO 100A 0 0 TO 150A 0 0 TO 200A 0
TO 250A TO 300A TO 350A TO 400A
INDUSTRIAL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 1-2%FS; FREQUENCY 50 TO 60HZ; RESPONSE 80m-SEC; TEMPERATURE -20° TO +70°C; POWERED BY INPUT; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A
AC CURRENT RANGES 0 TO 30A 0 0 TO 50A 0 0 TO 75A 0 0 TO 100A 0
TO 150A TO 200A TO 250A TO 300A
AC CURRENT RANGES 0 TO 30A 0 0 TO 40A 0 0 TO 50A 0 0 TO 75A 0
TO 100A TO 150A TO 200A TO 250A
INDUSTRIAL GRADE; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100m-SEC; TEMPERATURE –20° TO +85°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A 0 TO 25A
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
AC CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
8 OF 12
CONTINUED (PART TWO OF THREE)
SERIES
S383 XData Sheet
SERIES
1070 XData Sheet
SERIES
ACTS XData Sheet
SERIES
ACT XData Sheet
SERIES
1006 XData Sheet
SERIES
1006X XData Sheet
SERIES
S714 XData Sheet
SERIES
S786 XData Sheet
SERIES
1003AM2 XData Sheet
SERIES
1001 XData Sheet
PROCESS CONTROL; OUTPUT 4 TO 20mA; ACCURACY 0.5%FS; TWO WIRE LOOP POWER +7 TO +35VDC; FREQUENCY 50-60HZ; RESPONSE 100m-SEC; TEMPERATURE –40° TO +85°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS AC RMS; OUTPUT 4 TO 20mA; ACCURACY 0.25%FS; TWO WIRE LOOP POWER +12 TO +32VDC; FREQUENCY 20-2KHZ; RESPONSE 300m-SEC; TEMP –40° TO +85°C; APERTURE 3/4 INCH; PLASTIC CASE; BARRIER SCREW, CONNECTOR OR SUB-D TERMINATIONS
0 TO 2A 0 TO 5A 0 TO 10A 0 TO 15A
AC RMS CLAMP-ON; OUTPUT 4 TO 20mA; ACCURACY 0.8%FS; LOOP POWER +24 TO +40VDC; FREQUENCY 10-400HZ; RESPONSE 600mSEC; TEMPERATURE –20° TO +50°C; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS AC-AVG RESPONDING CLAMP-ON; OUTPUT 0 TO 5VDC, 0 TO 10VDC OR 4 TO 20mA; ACCURACY 0.5% OR 1%FS; SELF OR LOOP POWER; FREQUENCY 50-60HZ OR 20-100HZ; TEMPERATURE –20° TO +50°C; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS INDUSTRIAL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; FREQUENCY 50 TO 60HZ; RESPONSE 130m-SEC; TEMPERATURE -20° TO +70°C; POWERED BY INPUT; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
AC CURRENT RANGES 0 TO 30A 0 0 TO 40A 0 0 TO 50A 0 0 TO 75A 0
0 TO 2A 0 TO 5A 0 TO 10A 0 TO 20A
AC CURRENT RANGES 0 TO 50A 0 TO 75A 0 TO 100A 0 TO 150A
0 TO 20A 0 TO 25A 0 TO 30A 0 TO 40A
TO 100A TO 150A TO 200A TO 250A
0 TO 200A 0 TO 250A
AC CURRENT RANGES
-05: -50: -200:
0 TO 2A, OR 5A 0 TO 10A, 20A OR 50A 0 TO 100A, 150A OR 200A
AC CURRENT RANGES
-05: -50: -200:
0 TO 5A 0 TO 10A 0 TO 25A 0 TO 30A 0 TO 50A
0 TO 2A, OR 5A 0 TO 10A, 20A OR 50A 0 TO 100A, 150A OR 200A AC CURRENT RANGES 0 TO 75A 0 0 TO 100A 0 0 TO 150A 0 0 TO 250A 0 0 TO 400A
TO 500A TO 600A TO 800A TO1000A
0 TO 5A 0 TO 10A 0 TO 25A 0 TO 50A 0 TO 75A
AC CURRENT RANGES 0 TO 100A 0 TO 500A 0 TO 150A 0 TO 800A 0 TO 200A 0 TO 1000A 0 TO 300A 0 TO 1200A 0 TO 400A
0 TO 5A 0 TO 10A 0 TO 25A 0 TO 50A
AC CURRENT RANGES 0 TO 75A 0 TO 300A 0 TO 100A 0 TO 400A 0 TO 150A 0 TO 500A 0 TO 200A 0 TO 600A
RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; FREQUENCY 60HZ; POWER +14 TO +32VDC; RESPONSE 75m-SEC; TEMPERATURE -40° TO +85°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 5A 0 TO 10A 0 TO 20A 0 TO 25A 0 TO 50A
AC CURRENT RANGES 0 TO 75A 0 TO 400A 0 TO 100A 0 TO 500A 0 TO 150A 0 TO 600A 0 TO 200A 0 TO 800A 0 TO 300A 0 TO 1000A
AVG RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY 57-63HZ (OTHERS AVAILABLE); POWERED BY INPUT; RESPONSE 150mSEC; TEMPERATURE -20° TO +70°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 10A 0 TO 15A 0 TO 20A 0 TO 25A 0 TO 30A
INDUSTRIAL GRADE; OUTPUT 4 TO 20mADC; ACCURACY 0.5%FS; FREQUENCY 50 TO 60HZ; LOOP POWER +5 TO +35VDC; RESPONSE 100m-SEC; TEMPERATURE -20° TO +70°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; FREQ. 360 TO 440HZ; POWER +14 TO +32VDC; RESPONSE 75m-SEC; TEMPERATURE -40° TO +85°C; APERTURE 1+3/8 INCH DIA; METAL CASE; CONNECTOR OR BARRIER SCREW TERMINATIONS
CLAMP-ON RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY DC TO 480HZ; POWER +24 TO +32VDC; RESPONSE 100m-SEC; TEMPERATURE -25° TO +75°C; APERTURE 1+1/2 INCH DIA; METAL CASE; CONNECTOR OR BARRIER SCREW TERMINATIONS
0 TO 100A 0 TO 150A 0 TO 250A 0 TO 500A
AC CURRENT RANGES 0 TO 50A 0 TO 150A 0 TO 75A 0 TO 200A 0 TO 100A 0 TO 250A 0 TO 125A 0 TO 300A
AC CURRENT RANGES 0 TO 750A 0 TO 2000A 0 TO 1000A 0 TO 2500A 0 TO 1500A 0 TO 3000A
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
AC CURRENT TRANSDUCERS
DATA SHEETS AT
www.a-a-c.com
PAGE
9 OF 12
CONTINUED (PART THREE OF THREE)
SERIES
S461 XData Sheet
CLAMP-ON RMS RESPONDING; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; FREQUENCY DC TO 480HZ; POWER +24 TO +32VDC; RESPONSE 100m-SEC; TEMPERATURE -25° TO +71°C; APERTURE 1+1/2 INCH DIA; PLASTIC CASE; CONNECTOR OR BARRIER SCREW TERMINALS
0 TO 100A 0 TO 150A 0 TO 250A 0 TO 500A
AC CURRENT RANGES 0 TO 750A 0 TO 2000A 0 TO 1000A 0 TO 2500A 0 TO 1500A 0 TO 3000A
AC CURRENT DETECTORS
DATA SHEETS AT
www.a-a-c.com
NINE MODELS IN ORDER OF CURRENT RANGE
SERIES
870 XData Sheet
SERIES
S871 XData Sheet
SERIES
882 XData Sheet
SERIES
ACS XData Sheet
SERIES
ACS-3 XData Sheet
SERIES
ACS-SC XData Sheet
SERIES
881 XData Sheet
SERIES
880B XData Sheet
HEAVY INDUSTRIAL; OUTPUT SPDT-RELAY (10A CONTACTS); AUTO RESET; ADJUSTABLE (20% TO 100%); POWER 115VAC; FREQUENCY 47-63HZ; TEMPERATURE –20° TO +71°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 1A 0 TO 2A 0 TO 5A 0 TO 10A
AC CURRENT RANGES 0 TO 15A 0 TO 150A 0 TO 20A 0 TO 200A 0 TO 50A 0 TO 250A 0 TO 100A 0 TO 300A
WIDE FREQUENCY; OUTPUT SPDT-RELAY (10A CONTACTS); AUTO RESET; ADJUSTABLE (20% TO 100%); POWER 115VAC; FREQUENCY 47-400HZ; TEMPERATURE –20° TO +71°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 1A 0 TO 2A 0 TO 5A 0 TO 10A
AC CURRENT RANGES 0 TO 15A 0 TO 150A 0 TO 20A 0 TO 200A 0 TO 50A 0 TO 250A 0 TO 100A 0 TO 300A
CURRENT CONTROLLER: OUTPUT SPDT RELAY (2A CONTACTS); AUTO RESET; ADJUSTABLE (20% TO 100%); POWER 115VAC; FREQUENCY 50-400HZ; TEMPERATURE –20° TO +71°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 1A 0 TO 2A 0 TO 5A 0 TO 10A
AC CURRENT RANGES 0 TO 15A 0 TO 150A 0 TO 20A 0 TO 200A 0 TO 50A 0 TO 250A 0 TO 100A 0 TO 300A
CLAMP-ON SWITCH; OUTPUT SOLID STATE SWITCH; ADJUSTABLE OR FIXED; FREQUENCY 6-100HZ; RESPONSE 120m-SEC; TEMPERATURE -50° TO +65°C; POWERED BY INPUT; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 250MA 0 TO 500MA 0 TO 1A 0 TO 2A
AC CURRENT RANGES 0 TO 5A 0 0 TO 10A 0 0 TO 20A 0 0 TO 50A 0
CLAMP-ON SWITCH; OUTPUT SOLID STATE SWITCH; RANGE SELECTABLE; FREQUENCY 6-100HZ; RESPONSE 120m-SEC; TEMPERATURE -50° TO +65°C; POWERED BY INPUT; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS
CLAMP-ON SWITCH; OUTPUT SOLID STATE SWITCH; POWERED BY INPUT; FREQUENCY 6-100HZ; RESPONSE 200m-SEC; TEMPERATURE -50° TO +65°C; OPENING 0.85 X 0.85 INCH; PLASTIC CASE; BARRIER SCREW TERMINATIONS
1.5 TO 6A,
TO 100A TO 150A TO 200A TO 250A
AC CURRENT RANGES 6 TO 40A OR 40 TO 200A
SWITCH AVAILABLE NORMALLY OPEN OR NORMALLY CLOSED
0 TO 1A 0 TO 2A 0 TO 5A
AC CURRENT RANGES 0 TO 10A 0 TO 20A
AC CURRENT RANGES
INDUSTRIAL GRADE; OUTPUT SPDT-RELAY (2A CONTACTS); AUTOMATIC RESET; ADJUSTABLE TRIP POINT; POWER 115VAC; FREQUENCY 50400HZ; TEMPERATURE –20° TO +70°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 12A ............. (TRIP ADJ 2-12A) 0 TO 50A ............. (TRIP ADJ 8-50A) 0 TO 120A ........... (TRIP ADJ 40-120A) 0 TO 250A ........... (TRIP ADJ 100-250A)
INDUSTRIAL GRADE; OUTPUT SOLID STATE SWITCH; AUTOMATIC RESET; POWERED BY INPUT; ADJUSTABLE TRIP POINT; FREQUENCY 50-400HZ; TEMPERATURE –20° TO +70°C; APERTURE 3/4 INCH DIA; PLASTIC CASE; BARRIER SCREW TERMINATIONS
0 TO 12A ............. (TRIP ADJ 2-12A) 0 TO 50A ............. (TRIP ADJ 8-50A) 0 TO 120A ........... (TRIP ADJ 40-120A) 0 TO 250A ........... (TRIP ADJ 100-250A)
AC CURRENT RANGES
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
AC CURRENT DETECTORS
DATA SHEETS AT
www.a-a-c.com
PAGE
10 OF 12
CONTINUED (PART THREE OF THREE) SERIES
S212 XData Sheet
DATA SHEETS AT
AIRCRAFT DO-160; OUTPUT SPDT-RELAY; AUTOMATIC RESET; POWER +24 TO +32VDC; RESPONSE 200M-SEC; TEMPERATURE –55° TO +70°C; APERTURE 3/8 INCH DIA; METAL CASE; CONNECTOR TERMINATIONS; DO-160 ENVIRONMENTAL REQUIREMENTS
AC CURRENT RANGES
0 TO 75A (360-440HZ) RELAY TRIPS @ 0.5AAC ±0.75AAC
AC VOLTAGE TRANSDUCERS
www.a-a-c.com
EIGHT MODELS IN ORDER OF VOLTAGE RANGE
SERIES
108 XData Sheet
SERIES
108X XData Sheet
SERIES
S190 XData Sheet
SERIES
V XData Sheet
SERIES
VX XData Sheet
SERIES
101M3 XData Sheet
SERIES
102M3 XData Sheet
SERIES
105 XData Sheet
INDUSTRIAL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; RESPONSE 300mSEC; POWERED BY INPUT; FREQUENCY 57-63HZ (400HZ AVAILABLE); TEMPERATURE –20° TO +70°C; METAL CASE; BARRIER SCREW TERMINALS OR OPTIONAL CONNECTOR
AC VOLTAGE RANGES 0 TO 300V 0 TO 500V 0 TO 600V
0 TO 50V 0 TO 130V 0 TO 150V 0 TO 270V
AC VOLTAGE RANGES 0 TO 300V 0 TO 500V 0 TO 600V
PROCESS CONTROL; OUTPUT 4 TO 20mADC; ACCURACY 0.5%FS; RESPONSE 300m-SEC; LOOP POWER +10 TO +35VDC; FREQUENCY 57-63HZ (400HZ AVAILABLE); TEMPERATURE –20° TO +70°C; METAL CASE; BARRIER SCREW TERMINALS OR OPTIONAL CONNECTOR
0 TO 50V 0 TO 130V 0 TO 150V 0 TO 270V
INDUSTRIAL GRADE; OUTPUT 0 TO 10VDC; ACCURACY 2%FS; RESPONSE 200M-SEC; POWERED BY INPUT; FREQUENCY 47-63HZ (400HZ AVAILABLE); TEMPERATURE 0° TO +60°C; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 130V 0 TO 150V 0 TO 270V
AC VOLTAGE RANGES 0 TO 300V 0 TO 600V
UTILITY GRADE; OUTPUT 0 TO 1mADC; ACCURACY 0.25%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 47-1000HZ; TEMPERATURE – 20° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS
AC VOLTAGE RANGES 0 TO 150V 0 TO 300V 0 TO 500V
PROCESS CONTROL; OUTPUT 4 TO 20mADC; ACCURACY 0.5%FS; RESPONSE 400m-SEC; LOOP POWER +10 TO 32VDC; FREQUENCY 47-1000HZ; TEMPERATURE –20° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS
AC VOLTAGE RANGES 0 TO 150V 0 TO 300V 0 TO 500V
HIGH RESOLUTION; OUTPUT 0 TO 5VDC; ZERO SUPPRESSED INPUT RANGE; ACCURACY 0.5%FS; RESPONSE 1/2-CYCLE OF AC; POWERED BY INPUT; FREQUENCY 57-63HZ; TEMPERATURE -40° TO +70°C; METAL CASE; BARRIER SCREW TERMINALS
AC VOLTAGE RANGES 90 TO 150V
FAST RESPONSE; OUTPUT 0 TO 5VDC; POWERED BY INPUT; ACCURACY 0.5%FS; ZERO SUPPRESSED INPUT RANGE; RESPONSE 1-CYCLE OF AC; FREQUENCY 340-440HZ; TEMPERATURE -40° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS
AC VOLTAGE RANGES 90 TO 175V 105 TO 130V 175 TO 225V
ZERO SUPPRESSED INPUT RANGE; OUTPUT 0 TO 5VDC; ACCURACY 0.5%FS; RESPONSE 1-CYCLE OF AC; POWERED BY INPUT; FREQUENCY 57-63HZ; TEMPERATURE -40° TO +70°C; METAL CASE; BARRIER SCREW TERMINATIONS
AC VOLTAGE RANGES 390 TO 490V 455 TO 505V 430 TO 530V
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
DATA SHEETS AT
DC VOLTAGE TRANSDUCER & DETECTOR
www.a-a-c.com
PAGE
11 OF 12
TWO MODELS IN ORDER OF VOLTAGE RANGE
SERIES
S657 XData Sheet
SERIES
S631 XData Sheet
RAIL TRANSIT GRADE; OUTPUT 4 TO 20MADC PROPORTIONAL TO (±) INPUT ABSOLUTE VALUE; ACCURACY 1%FS OVER TEMP; ISOLATION 5KV; RESPONSE 5M-SEC; POWER +22 TO +26VDC; TEMPERATURE –40° TO +85°C; PLASTIC CASE; CONNECTOR AND MATING CONNECTORS INCLUDED
DC VOLTAGE RANGES
0 TO ±150V 0 TO ±750V 0 TO ±300V 0 TO ±1200V 0 TO ±500V 0 TO ±1500V 0 TO ±2000V DC VOLTAGE RANGE 0 TO +800V
RAIL TRANSIT GRADE; OUTPUT SPST RELAY (10A CONTACTS); AUTOMATIC RESET @ +365VDC; ACCURACY 1%FS; RESPONSE 110m-SEC; POWER +25 TO +45VDC; TEMPERATURE –25° TO +75°C; PLASTIC CASE; BARRIER SCREW TERMINATIONS
DATA SHEETS AT
RELAY TRIPS @ +375VDC ±2VDC
AC POWER TRANSDUCERS
www.a-a-c.com
FIVE MODELS IN ORDER OF POWER RANGE
SERIES
W&Q XData Sheet
SERIES
S73 XData Sheet
SERIES
415A XData Sheet
SERIES
416A XData Sheet
SERIES
S217 XData Sheet
DATA SHEETS AT
UTILITY GRADE; 1φ AND 3φ WATT & VAR TRANSDUCERS; FREQUENCY 60HZ (50 & 400HZ AVAILABLE); OUTPUT 0 TO ±1mADC (±5V & ±10VDC AVAILABLE); ACCURACY 0.25%FS; RESPONSE 400m-SEC; POWERED BY INPUT; TEMPERATURE –20° TO +70°C
AC POWER RANGES
0 TO 6.5AAC AND 85 TO 140VAC 1φ (2-WIRE) ACCEPTS BALANCED 3φ (3-WIRE) OR UNRESTRICTED 3φ (4-WIRE) LOADS & VOLTAGE
BARRIER SCREW TERMINATIONS
0 TO 1KW 0 TO 2KW 0 TO 2.5KW 0 TO 5KW
AC POWER RANGES 0 TO 10KW 0 TO 40KW 0 TO 15KW 0 TO 50KW 0 TO 20KW 0 TO 60KW 0 TO 30KW 0 TO 100KW
80-150VAC OR 160-230VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 5763HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 1KW 0 TO 2KW 0 TO 2.5KW 0 TO 5KW
AC POWER RANGES 0 TO 10KW 0 TO 40KW 0 TO 15KW 0 TO 50KW 0 TO 20KW 0 TO 60KW 0 TO 30KW 0 TO 100KW
TERMINATIONS
0 TO 4KW 0 TO 10KW 0 TO 20KW
AC POWER RANGES 0 TO 40KW 0 TO 100KW 0 TO 50KW 0 TO 200KW 0 TO 80KW
160-300VAC & 320-480VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 5763HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW TERMINATIONS
0 TO 2-4KW 0 TO 5-10KW 0 TO 10-20KW
0-115VAC OR 0-230VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWER 120VAC; FREQUENCY 57-63HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE;
320-560VAC; OUTPUT 0 TO +5VDC; ACCURACY 2%FS; RESPONSE 400m-SEC; POWERED BY INPUT; FREQUENCY 57-63HZ; TEMPERATURE 0° TO +50°C; APERTURE 3/4 INCH DIA; METAL CASE; BARRIER SCREW
AC POWER RANGES 0 TO 20-40KW 0 TO 25-50KW 0 TO 40-80KW
FREQUENCY TRANSDUCERS
www.a-a-c.com
TWO MODELS IN ORDER OF FREQUENCY RANGE SERIES
S350L XData Sheet
FLIGHT TEST; OUTPUT 0 TO 5VDC; LINEARITY 0.1%FS; INPUT VOLTAGES FROM 20MV TO 50V-RMS; RESPONSE =30/FREQUENCY; POWER +22 TO +30VDC; TEMPERATURE –48° TO +74°C; METAL CASE; CONNECTOR TERMINATIONS
100HZ 200HZ 300HZ 500HZ
FREQUENCY RANGES 1KHZ 5KHZ 2KHZ 10KHZ 3KHZ 20KHZ
FREQUENCY RANGES
SERIES
S343 XData Sheet
MIL GRADE; OUTPUT 0 TO 5VDC; ACCURACY 1%FS; RESPONSE 250M-SEC; POWERED BY INPUT; TEMPERATURE –40° TO +70°C; RANGE & ZERO ADJUSTMENTS; METAL CASE; CONNECTOR TERMINATIONS
360 TO 440HZ @ 102-127VAC 360 TO 440HZ @ 200-250VAC AVAILABLE FIELD ADJUSTMENTS RANGE (±3%) & ZERO (±3%)
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
CERTIFIED
ISO 9001:2000 & AS9100:2004 REV B PERRY JOHNSON REGISTRAS
SF CATALOG
705
Current Voltage Power & Frequency Transducers
PAGE
12 OF 12
5-YEAR WARRANTY: AAC warrants all the products in this catalog to be free from defects in material and workmanship. The warranty applies to the product or parts thereof returned to AAC, with transportation charges prepaid, within five years of the original date of delivery to the original purchaser. Our obligation is limited to servicing, adjusting or replacing, at AAC option, any product or part thereof. Returns to the factory must be authorized in advance. For products sold to a manufacturer that uses it within an assembly made for resale, the remaining warranty is transferable, providing the product is sold as original equipment. Since 1965 we have continued to strive toward higher levels of product performance, quality and service. AAC provides AC & DC current, voltage, power and frequency transducers for: Industrial automation; laboratory; rail transit; land vehicles; shipboard; aircraft, missile and space flight applications. Products in this catalog represent only part of a broad line of measurement and control instrumentation. In addition, there are numerous and diverse variations available for unique applications.
Quality, reliability and safety are designed in and carefully monitored throughout each process from order entry to shipment. Systems are based on IPC industry standard plus calibration and metrology traceable to NIST. Many of our products are UL, CSA and EU recognized and come with a FIVE YEAR WARRANTY. AAC is a woman owned small business certified to ISO 9001:2000 & AS9100:2004(B).
New and innovative products are continually being developed to meet customer requirements. Product designs focus on the user’s needs and our customers demand for competitive prices and quick delivery. This is the reason we offer a wide product selection from stock and continue to develop application specific modifications and custom products.
Maintaining a long cherished reputation for outstanding customer service is considered an important priority. Every attempt is made to satisfy any reasonable request. AAC computerized tracking schedule continuously monitors customer orders and provides immediate status upon request. An experienced staff stands ready to assist with product selections and to recommend alternative instrumentation solutions.
The fast delivery of cost effective products is due to: X State of the art CAD engineering from circuit analysis to mechanical design. Y Computerized inventory for quick access to parts and materials.
AAC American Aerospace Controls, Inc. 570 Smith Street, Farmingdale New York 11735-1115 USA
Z Up-to-date in house manufacturing including: coil winding, automated soldering, surface mount technology, encapsulation and more.
Telephone: (631) 694-5100 Toll Free: (888) 873-8559 Facsimile: (631) 694-6739
[ In house testing – random vibration, mechanical shock, thermal vacuum, high-energy pulse testing, high current and high voltage testing.
E-Mail: aac@rcn.com Website: http://www.a-a-c.com
AAC – American Aerospace Controls, Inc. 570 Smith Street, Farmingdale, New York 11735-1115 Tel: (631) 694-5100 Website: http://www.a-a-c.com
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT SENSOR SERIES 905B
PART NO.
INPUT CURRENT RANGE
905B-50 .......................0 TO ±50mA 905B-100 .....................0 TO ±100mA 905B-200 .....................0 TO ±200mA 905B-500 .....................0 TO ±500mA
INPUT CURRENT RANGE
PART NO.
905B-1 ..................................... 0 TO ±1A 905B-1.5 .................................. 0 TO ±1.5A 905B-2 ..................................... 0 TO ±2A 905B-5 ..................................... 0 TO ±5A
OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ± 5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RIPPLE .............................................................................. 2% FS RMS max. RESPONSE....................................................................... 50 m-sec. max. (10 to 90%) IMPEDANCE ..................................................................... 1000 Ohms ±5%, 5mA to 1A range 666 Ohms 1.5A range, 500 Ohms 2A range, 200 Ohms 5A range TEMPERATURE COEFFICIENT...................................... ±.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. ±50mAdc max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -55°C to +85°C STORAGE TEMPERATURE RANGE .............................. -55°C to +85°C INSULATION RESISTANCE ............................................ 100 M-ohms (A thru E to case) DIELECTRIC STRENGTH................................................ 350V RMS (A thru E to case) ALTITUDE ......................................................................... Operating sea level to 60,000 ft. VIBRATION ....................................................................... Operating 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK .............................................................................. Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE ............................................... Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Meets spec. for any mounting position RIPPLE .............................................................................. 40mV reflected onto pass-thru line WEIGHT ............................................................................ 1.25 lbs. max.
TERMINAL IDENTIFICATION A. B. C. D. E. F.
Code Ident. No. 15948
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+) CASE GROUND
AAC
Drawing Number
Rev.
700-905B
K
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES S661B CURRENT PART NUMBER RANGE S661B-100 ...........................0 to 100mA S661B-200 ...........................0 to 200mA S661B-250 ...........................0 to 250mA S661B-300 ...........................0 to 300mA
PART CURRENT NUMBER RANGE S661B-400 ......................... 0 to 400mA S661B-500 ......................... 0 to 500mA S661B-750 ......................... 0 to 750mA S661B-1A........................... 0 to 1A
INPUT POWER RANGE NOMINAL.................................................... OVERLOAD .............................................................. VOLTAGE ................................................................. FREQUENCY RANGE .............................................
See Table mAdc or Ac peak 0 to ±25 Adc 1000 Vrms DC to 60Hz
OUTPUT VOLTAGE SIGNAL................................................... ACCURACY ............................................................ TEMPERATURE COEFFICIENT ............................. OUTPUT IMPEDANCE ............................................ RESPONSE TIME (10 TO 90%) .............................. SHORT CIRCIUT ..................................................... RIPPLE .....................................................................
0 to ±5Vdc or Ac peak ±1% Full Scale ±0.02% FS/°C max. 250 Ohms max. 1 Msec. max. Protected 1% FS RMS
POWER SUPPLY SUPPLY VOLTAGE.................................................. ± 15Vdc (±0.5Vdc) CURRENT DRAIN.................................................... 50mA PROTECTION .......................................................... Reverse Polarity Protected
TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE(-) C. SUPPLY RTN D. OUTPUT RTN E. OUTPUT SIGNAL (+) F. CASE GROUND
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................ -40 to +85°C STORAGE TEMPERATURE ................................... -50 to +85 °C OPERATING HUMIDITY .......................................... 0 to 95% RH Operating MOISTURE RESISTANCE ...................................... Will meet method 106 of Mil-Std-202, Method 507.3 procedure 1 of Mil-Std-810. SALT FOG ................................................................ Mil-Std-202, Method 101, 5% salt solution FUNGUS................................................................... Mil-Std-810, Table 508.4 ALTITUDE................................................................. Operating Sea Level to 60,000 Ft. SHOCK ..................................................................... Operating 50g, 11 m-sec half sine pulse Method 213B condition A of Mil-std-202 VIBRATION............................................................... Operating 0.06 inch D.A. 10Hz to 55Hz Method 201A and Random Method 214A Test Condition 1 Level D, 3 Min. Per Axis, 11.95 Overall RMS G, Per Mil-Std-202. ATTITUDE ................................................................ Performs in any position WEIGHT ................................................................... 0.95 lbs. Max. ESD RATING............................................................ 2000V
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S661B-905
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT SENSOR SERIES 926
INPUT CURRENT MODEL NUMBER 926-5 .. .................................................. 0 TO ±5 926-10 .................................................. 0 TO ±10 926-15 .................................................. 0 TO ±15 926-20 .................................................. 0 TO ±20 926-25 .................................................. 0 TO ±25 INPUT CURRENT RANGE........................................................... Adc See Table CURRENT OVERLOAD.................................................... ±100Adc Nondestructive/Nonlatching/ Saturated Output OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ±5Vdc FS (Full Scale) ACCURACY....................................................................... ±0.25% FS (±12.5mV) OUTPUT IMPEDANCE ..................................................... 100 Ohms max. OUTPUT RIPPLE.............................................................. 0.2% FS RMS max. RESPONSE (10 TO 90%)................................................. 5 m-sec max. TEMPERATURE COEFFICIENT...................................... ±0.006% FS/°C max. OUTPUT PROTECTION .................................................. Short CKT continuously no damage OUTPUT ISOLATION ....................................................... Output/Supply & Case all isolated POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 85mAdc max. OVER VOLTAGE PROTECTION..................................... ±35Vdc without damage REVERSE POLARITY PROTECTION .............................10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -55° to +85°C STORAGE TEMPERATURE ............................................ -55° to +100°C OPERATING HUMIDITY................................................... 0% to 95% RH MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 ALTITUDE ......................................................................... Operating sea level to 60,000 ft. SHOCK .............................................................................. Operating - 50g, 11m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) VIBRATION ....................................................................... Operating - 0.06 inch D.A., 10 to 55Hz (Method 201 of MIL-STD-202) DIELECTRIC STRENGTH................................................ 350V RMS (Method 301 of MIL-STD-202) INSULATION RESISTANCE ............................................ 100-M-Ohms min. @ 500Vdc ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. WEIGHT ............................................................................ 1.25 lbs. Max.
TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT SIGNAL (RTN) D. SPARE E. OUTPUT SIGNAL (+) F. CASE GROUND
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-926
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES S764 PART CURRENT NUMBER RANGE S764-50…………………0 to ±50 S764-60…………………0 to ±60 S764-70…………………0 to ±70 S764-100………………. 0 to ±100
PART CURRENT NUMBER RANGE S764-20 .........................0 to ±20 S764-25 .........................0 to ±25 S764-30 .........................0 to ±30 S764-40…………………0 to ±40 INPUT RANGE .............................................................................. OVERLOAD CONTINUOUS............................................. FREQUENCY RANGE ......................................................
See Table Adc ±2000Adc DC to 350Hz
OUTPUT VOLTAGE SIGNAL ........................................................... ACCURACY....................................................................... RESPONSE (10 to 90%) ................................................... OUTPUT IMPEDANCE ..................................................... LOAD RESISTANCE ........................................................ TEMPERATURE COEFFICIENT...................................... OUTPUT PROTECTION ..................................................
0 to ±5Vdc FS ±1% FS 1 m sec. 10 Ohms 10k Ohms min ±.02%FS per °c max. Short Circuit
POWER SUPPLY SUPPLY VOLTAGE ......................................................... CURRENT DRAIN............................................................. PROTECTION................................................................... TRANSIENT PROTECTION.............................................
+12Vdc to +36Vdc 10mAdc max. Reverse polarity protected ±60V (T<5mS)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -40° to +85°C STORAGE TEMPERATURE RANGE .............................. -40° to +85°C ISOLATION ....................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE ............................................ 500 M-Ohms @ 500Vdc CASE MATERIAL.............................................................. Molded Plastic meets UL flammability rating 94V-O WEIGHT ........................................................................... 10 oz. Max.
TERMINAL IDENTIFICATION 1. 2.
3. 4.
SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+)
TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S764
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 BIDIRECTIONAL CURRENT SENSOR SERIES S273 TEMPERATURE PART NO.
INPUT CURRENT
ACCURACY
COEFFICIENT
S273-25 .......................0 to ±25A ...........................
1%................................. .08%
S273-50 .......................0 to ±50A ...........................
1%................................. .06%
S273-100 .....................0 to ±100A ......................... .5%................................. .04% S273-150 .....................0 to ±150A ......................... .5%................................. .02% S273-200 .....................0 to ±200A ......................... .5%................................. .02% S273-250 .....................0 to ±250A ......................... .5%................................. .02% S273-300 .....................0 to ±300A ......................... .5%................................. .02% S273-350 .....................0 to ±350A ......................... .5%................................. .02% OUTPUT VOLTAGE SIGNAL ........................................................... ACCURACY....................................................................... di/dt ACCURATELY FOLLOWED..................................... DELAY TIME ..................................................................... BANDWIDTH .................................................................... IMPEDANCE .....................................................................
0 to ±5Vdc FS (Full Scale) % FS See Table Better than 50A/u-sec. Better than 1u-sec. DC to 100KHz 500 Ohms (25A) 200 Ohms max. (50 -350A) FS/°C max. See Table
TEMPERATURE COEFFICIENT...................................... POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. 100mAdc max. REVERSE POLARITY PROTECTION ............................. 10µA max. current drain no damage. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -55° to +85°C STORAGE TEMPERATURE ............................................ -55° to +85°C OPERATING HUMIDITY................................................... 0% to 95% RH MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Procedure I of MIL-STD-810 ALTITUDE ......................................................................... Operating: Sea level to 60,000 ft. Non-operating: Sea level to 120,000 ft. (Method 105, Condition A of MIL-STD-202) SHOCK .............................................................................. Non-operating: 50g, 11m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) VIBRATION ....................................................................... Non-operating: 0.06 in. D.A., 10 to 55Hz (Method 201 of MIL-STD-202) DIELECTRIC STRENGTH................................................ 350V RMS dielectric withstanding voltage (Method 301 of MIL-STD-202) INSULATION RESISTANCE ............................................ 10M-Ohms min. (Method 302, Condition A of MIL-STD-202) ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. WEIGHT ........................................................................... 14 oz. max. TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (-) C. SUPPLY VOLTAGE (RTN) D. OUTPUT SIGNAL (RTN) E. OUTPUT SIGNAL (+) F. CASE GROUND
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-S273-925
K
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 BIDIRECTIONAL CURRENT TRANSDUCER SERIES S449
TEMPERATURE PART NO.
INPUT CURRENT
ACCURACY
COEFFICIENT
S449-25 .........................0 to ±25................................ ±1.0% ............................ ±0.05% S449-40 .........................0 to ±40................................ ±0.5% ............................ ±0.03% S449-50 .........................0 to ±50................................ ±0.5% ............................ ±0.025% S449-60 .........................0 to ±60................................ ±0.5% ............................ ±0.025% INPUT CURRENT RANGE................................................................... FREQUENCY RANGE .............................................................. CURRENT OVERLOAD............................................................
Adc or ac peak See Table DC to 2KHz continuous operation Unlimited (Nondestructive Nonlatching/ Saturated Output)
OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... OUTPUT IMPEDANCE ............................................................. RESPONSE (10 to 90%) ........................................................... BANDWIDTH ............................................................................ TEMPERATURE COEFFICIENT.............................................. OUTPUT NOISE ....................................................................... LINEAR OVER RANGE ............................................................
0 to ±5.0Vdc FS (Full Scale) See Table 400 Ohms max. 1u-sec max. DC to 100KHz FS/°C max. See Table 10mV RMS max. 10% above FS
POWER SUPPLY SUPPLY VOLTAGE ................................................................. CURRENT DRAIN..................................................................... MAX. OVER VOLTAGE ............................................................ REVERSE POLARITY ..............................................................
±15Vdc ±250mV ±40mA max. ±17Vdc continuous (Nondestructive) 10µA drain (Nondestructive)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE (TC) ........................................ STORAGE TEMPERATURE .................................................... ISOLATION : INPUT/OUTPUT/CASE ..................................... INSULATION RESISTANCE .................................................... CASE ........................................................................................ FINISH ....................................................................................... WEIGHT ...................................................................................
-40° to +71°C -55° to +125°C 1050V RMS max. 200M-Ohms @ 500Vdc Hermetic seal Fuse Tin Plate 4 oz. max.
TERMINAL IDENTIFICATION A. B. C. D. E.
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT (+)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S449
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 BIDIRECTIONAL CURRENT TRANSDUCER SERIES S745 RESPONSE INPUT RANGE ACCURACY TIME BANDWIDTH PART NO. S745-40 ........... 0 to ±40 Adc.............. ±1 ................. 2u-sec ........ 175Khz ........... S745-75............ 0 to ±75 Adc.............. ±0.75 ............ 1.5u-sec ..... 233Khz ........... S745-150.......... 0 to ±150 Adc............ ±0.5 .............. 1.0u-sec ..... 350Khz ........... S745-250.......... 0 to ±250 Adc............ ±0.5 .............. 1.0u-sec ..... 350Khz ...........
TEMP. COEFF. .05% .04% .03% .03%
INPUT CURRENT RANGE NOMINAL .................................................. See Table OVERLOAD ............................................................ Unlimited (Nondestructive Nonlatching Saturated output) FREQUENCY RANGE ............................................ DC to 20KHz OUTPUT VOLTAGE SIGNAL ................................................. ACCURACY (ROOM TEMP) .................................. TEMPERATURE COEFFICIENT ............................ OUTPUT IMPEDANCE ........................................... RESPONSE TIME (10 TO 90%) ............................. BANDWIDTH .......................................................... OUTPUT PROTECTION ......................................... OUTPUT LOAD.......................................................
0 to ±5Vdc (Full Scale) % FS see table Per °C max. see table 10 Ohms max. Max. see table DC to see table Short Circuit 5K Ohm min.
POWER SUPPLY SUPPLY VOLTAGE ................................................ ±12Vdc (±1Vdc) CURRENT DRAIN .................................................. +15mA max -5mA max. PROTECTION......................................................... Reverse Polarity Protected
TERMINAL IDENTIFICATION A. B. C. D. E.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............................... -55 to +100°C STORAGE TEMPERATURE .................................. -55°C to +100 °C RADIATION............................................................. Operating as specified with a total dose of 1 KRAD (SI). SEL of 37 MeV (no latch or up-set). SHOCK ................................................................... 100 g, 6 m-sec half sine pulse VIBRATION............................................................. 50g HUMIDITY............................................................... 0 to 100% RH Operating INSULATION RESISTANCE................................... 500M-Ohms @ 500Vdc DIELECTRIC STRENGTH ..................................... 1500Vdc FINISH .................................................................... Fuse Tin Plate WEIGHT.................................................................. 0.49 lbs. Max.
SUPPLY (+) SUPPLY (RTN) SUPPLY (-) OUTPUT (+) OUTPUT (RTN)
AAC Code Ident. No. 15948
Drawing Number
700-S745A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Rev.
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES 929 PART CURRENT RANGE NUMBER 929-50.......................... 0 to ±50 929-75 .......................... 0 to ±75 929-100........................ 0 to ±100 929-150………………….0 to ±150
PART CURRENT NUMBER RANGE 929-200………………… 0 to ±200 929-250………………… 0 to ±250 929-300………………… 0 to ±300 929-400………………… 0 to ±400
INPUT RANGE ........................................................................... OVERLOAD CONTINUOUS ........................................... FREQUENCY RANGE....................................................
See Table Adc or AC Peak ±5000Adc DC to 350KHz
OUTPUT VOLTAGE SIGNAL ......................................................... ACCURACY (Over Temperature Range)........................ RESPONSE (10 to 90%)................................................. OUTPUT IMPEDANCE ................................................... LOAD RESISTANCE ..................................................... OUTPUT PROTECTION.................................................
0 to ±5Vdc FS ±1% FS (note 1) 1 u-sec. max. 25 Ohms 5k Ohms min Short Circuit
POWER SUPPLY SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... PROTECTION................................................................. TRANSIENT PROTECTION ...........................................
+10Vdc to +34Vdc 8mAdc max. Reverse polarity protected ±60V (T<5mS)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -40° to +85°C STORAGE TEMPERATURE RANGE............................. -55° to +125°C HUMIDITY (Operating).................................................... 0% to 95%RH MOISTURE RESISTANCE ............................................. MIL-STD-202 Method 106 (note 2) 2 RANDOM VIBRATION (Operating)................................. MIL-STD-810F, Proc.1,Cat.12, WO=.095G /Hz, Time1 hr, Fig. 514.5C-8 Overall level 12.G-RMS SHOCK ........................................................................... 50g 11m-sec. half sine pulse ISOLATION ..................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE........................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O (color light gray) WEIGHT ......................................................................... 6 oz. Max. NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. NOTE 2: Meets Specified Moisture requirements with option C & D only. TERMINAL IDENTIFICATION 1. 2.
SUPPLY VOLTAGE (+) SUPPLY (RTN)
3. 4.
OUTPUT (RTN) OUTPUT SIGNAL (+)
5-9. SPARE
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-929
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES S651 PART NUMBER S651-100-C S651-200-C
TERMINAL IDENTIFICATION A. B. C. D. E. F.
SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SINGAL (+) CASE GROUND SPARE
INPUT CURRENT RANGE 0 TO ±100Adc 0 TO ±200Adc
±100 TO ±125Adc ±200 TO ±250Adc
INPUT RANGE ................................................... See Table OVER RANGE CAPABILITY .................. See Table CURRENT OVERLOAD.......................... ± 5000 amps. DC continuous OUTPUT VOLTAGE SIGNAL ................................ 0 to ± 5Vdc FS ( ±5 to ±6.25Vdc OR ) ACCURACY ............................................ ± 1% (± 50mV) Over -10°C to +65°C LOW TEMP. OPERATION...................... @ -40°C to -10°C Accuracy / Linearity ±2.5% FS ACCURACY OVER RANGE(OR) ........... 2.5% FS LINEARITY.............................................. ±0.5% FS RESPONSE (10 TO 90%)....................... 100 u-sec max. OUTPUT LOAD CURRENT .................... 5mA max. OUTPUT IMPEDANCE ........................... 100 Ω max. POWER SUPPLY SUPPLY VOLTAGE ............................... +22 to 32Vdc CURRENT DRAIN .................................. 140mA max. REVERSE POLARITY PROTECTION.... 10uA max. current drain without damage TRANSIENT............................................ 40V for 20 m-sec ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............... -40°C to +65°C STORAGE TEMPERATURE .................. -55°C to +71°C OPERATING HUMIDITY......................... 0% to 95% RH MOISTURE RESISTANCE .................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE............................................... Operating: Sea Level to 27,000 FT. Non-Operating: Sea Level to 70,000Ft. 2 VIBRATION............................................. 20 to 40Hz + 6dB/ Octave 40 to 120Hz 0.02 G /Hz, 120 2 to 150 Slope By End Point, 150 to 800Hz 0.04 G /Hz, 800-2000 Hz -6dB/Octave ACCELERATION ................................... Operating ±5g’s In All Axes, Both Directions DIELECTRIC STRENGTH ..................... 350V RMS Terminals 1-5 & Case. INSULATION RESISTANCE .................. 1 MΩ @ 200Vdc ATTITUDE............................................... Unit Will Perform As Specified When Mounted In Any Position. SHOCK .................................................. Operating: 20g, Peak Terminal Sawtooth Pulse 11 Milli seconds Duration, All Planes, Both Directions. WEIGHT ................................................. 1.5 lbs. max. COMPONENTS DERATING (EEE COMPONENTS) ........ Derated To The Intent of Naval Air Systems Command AS-4613. MICROCIRCUITS ................................... MIL-M-38510 Class B QPL or DESC DWG. SEMICONDUCTORS.............................. MIL-S-19500 (JANTX) CAPACITORS......................................... MIL-C-39003, MIL-C-39014 (Level R) RESISTORS ........................................... MIL-R-39007, -39008, -39035,-55182 (Level R) TRANSFORMERS & INDUCTORS ........ MIL-T-27 (Class S)
AAC Code Ident. No. 15948
OVER RANGE
Drawing Number
Rev.
700-S651-942
H
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES S784 CURRENT PART CURRENT PART NUMBER RANGE NUMBER RANGE S784-100..............................0 to ±100 S784-400.............................. 0 to ±400 S784-200..............................0 to ±200 S784-500.............................. 0 to ±500 S784-250..............................0 to ±250 S784-600.............................. 0 to ±600 S784-300..............................0 to ±300 S784-750.............................. 0 to ±750 INPUT RANGE ............................................................................. See Table Adc FREQUENCY ................................................................... DC to 1kHz OVERLOAD CURRENT CONTINOUSE ......................... 10KAdc OUTPUT VOLTAGE SIGNAL........................................................... 0 to ±5Vdc FS ACCURACY...................................................................... ±1% FS RESPONSE TIME (10 TO 90%) ..................................... 500 u-sec. max. OUTPUT IMPEDANCE .................................................... 250 Ohms max. TEMPERATURE COEFFICIENT ..................................... ±.02%FS Per°c max. OUTPUT PROTECTION.................................................. Short CKT RECOMMEND OUTPUT LOAD....................................... 50KΩ or greater POWER SUPPLY SUPPLY VOLTAGE ......................................................... +16Vdc to +40Vdc nominal CURRENT DRAIN............................................................ 10mA max. REVERSE POLARITY PROTECTION ............................ 100µA max. Current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -40°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 MOUNTING ...................................................................... Rigid in any position INSULATION RESISTANCE............................................ 200 M-Ohms min. MIL-STD-202 Method 302 Test Condition A WEIGHT ........................................................................... 9 oz. max.
TERMINAL IDENTIFICATION A. B. C. D. E.
SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+) SPARE
CATEGORY SECTION DO-160D ENVIRONMENT TEMPERATURE & ALTITUDE A2 4 TEMPERATURE VARIATION A 5 HUMIDITY A 6 SHOCK & CRASH SAFTY REQ’D 7 VIBRATION H2 CURVE C&R 8 EXPLOSION PROOF X 9 FLUID SUSCEPTIBILITY X 11 SAND AND DUST X 12 FUNGUS RESISTANCE F 13 SALT SPRAY X 14 MAGNETIC EFFECT X 15 VOLTAGE SPIKE A 17 AUDIO FREQUENCY SUSCEPTIBILITY A 18 INDUCED SIGNAL SUSCEPTIBILITY A 19 RADIO FREQUENCY SUSCEPTIBILITY A 20 EMMISION OF RADIO FREQUENCY ENERGY Z 21 LIGHTNING INDUCED TRANSIENT SUSCEPTIBILITY A3C3 22 LIGHTNING DIRECT EFFECT X 23 STATIC DISCHARGE A
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S784
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES 947 TEMPERATURE INPUT CURRENT COEFFICIENT PART NO. 947-100 ................................ 0 to ±100................................... .02% 947-200 ................................ 0 to ±200................................... .01% 947-300 ................................ 0 to ±300.................................. .01% 947-400 ................................ 0 to ±400.................................. .01% 947-500 ................................ 0 to ±500.................................. .01% 947-600 ................................ 0 to ±600.................................. .01% INPUT RANGE ........................................................................................ Amps. DC or AC peak. See Table CURRENT OVERLOAD.............................................................. ±5000 amps. DC continuous FREQUENCY .............................................................................. DC to 100KHz OUTPUT VOLTAGE SIGNAL...................................................................... ACCURACY................................................................................. LINEARITY................................................................................... DI DT CAPABILITY...................................................................... DELAY TIME................................................................................ OUTPUT IMPEDANCE ............................................................... TEMPERATURE COEFFICIENT ................................................
0 to ±5Vdc FS (Full Scale) ± 0.5% FS ±0.1% FS 50A per u-sec 1 u-sec 100 Ohms max. % FS per °C. See Table
POWER SUPPLY SUPPLY VOLTAGE..................................................................... ±15Vdc ±1Vdc CURRENT DRAIN....................................................................... 150mA max. REVERSE POLARITY PROTECTION ....................................... 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................... STORAGE TEMPERATURE ...................................................... OPERATING HUMIDITY ............................................................. INSULATION RESISTANCE....................................................... ATTITUDE ...................................................................................
- 20° C to 70°C - 45°C to 85°C 0% to 95% RH 100 M-Ohms min. Unit will perform as specified when mounted in any position. SHOCK ........................................................................................ Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202 WEIGHT ...................................................................................... 1.5 lbs. max.
TERMINALS:
TERMINAL IDENTIFICATION
6-32 SCREWS, .325” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO .26” WIDE.
1. 2. 3. 4. 5.
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (±)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-947
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT SENSOR SERIES 943A TEMPERATURE INPUT CURRENT COEFFICIENT SUPPLY CURRENT PART NO. 943-100................... 0 to ±100 ......................... .04% ...................................... 85mA 943-200................... 0 to ±200 .......................... .04% ...................................... 115mA 943-300................... 0 to ±300 .......................... .02% ...................................... 165mA 943-400................... 0 to ±400 .......................... .02% ...................................... 215mA 943-500................... 0 to ±500 .......................... .02% ...................................... 265mA 943-600................... 0 to ±600 .......................... .01% ...................................... 265mA 943-750................... 0 to ±750 .......................... .01% ...................................... 265mA 943-800................... 0 to ±800 .......................... .01% ...................................... 265mA 943-1000................. 0 to ±1000 ......................... .01% ...................................... 265mA INPUT CURRENT RANGE ........................................................................................ CURRENT OVERLOAD.............................................................. FREQUENCY .............................................................................. OUTPUT VOLTAGE SIGNAL ..................................................................... ACCURACY................................................................................. LINEARITY .................................................................................. BANDWIDTH .............................................................................. RESPONSE TIME (10 to 90%) ................................................... OUTPUT IMPEDANCE ............................................................... TEMPERATURE COEFFICIENT................................................ POWER SUPPLY SUPPLY VOLTAGE .................................................................... CURRENT DRAIN....................................................................... REVERSE POLARITY PROTECTION ....................................... ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE .................................................. STORAGE TEMPERATURE ...................................................... OPERATING HUMIDITY............................................................. MOISTURE RESISTANCE .........................................................
MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.
ALTITUDE ................................................................................... RANDOM VIBRATION................................................................
DIELECTRIC STRENGTH.......................................................... INSULATION RESISTANCE ...................................................... ATTITUDE ................................................................................... TERMINAL IDENTIFICATION 12345-
Code Ident. No. 15948
A. SUPPLY VOLTAGE (+) B. SUPPLY & OUTPUT (RTN) C. SUPPLY VOLTAGE (-) D. OUTPUT SIGNAL (+) E. CASE GROUND F. SPARE
SHOCK ........................................................................................
WEIGHT ......................................................................................
AAC
Amps. DC or AC peak. See Table ±5000 amps. DC continuous DC to 350KHz 0 to ±5Vdc FS (Full Scale) ± 0.5% FS ±0.1% FS DC to 350KHz 1 u-sec 100 Ohms max. % FS per °C. See Table ±15Vdc ±1Vdc See Table mA max. 10µA max. current drain without damage - 55° C to +85°C - 55°C to +100°C 0% to 95% RH Will meet Method 106 of MIL-STD -202 & Method 507.1, Proc. 1 of MIL-STD-810 Operating: Sea level to 70,000 ft. Operating MIL-STD-810E Category 5, 2 Proc. 1, WO=0.012G Hz, duration 1 Hr. Figure 514. 4-8 suggested vibration levels for high performance Aircraft 12.5 G-RMS composite min. 350V RMS terminals 1-4 to 5 & case 100 M-Ohms min. Unit will perform as specified when mounted in any position. Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD202 1.5 lbs. max.
Drawing Number
Rev.
700-943A
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT SENSOR SERIES 944 INPUT RANGE PART NUMBER 944-600 ............................................... 0 TO ±600 944-800 ............................................... 0 TO ±800 944-1000 ........................................... 0 TO ±1000 944-1500 ........................................... 0 TO ±1500 944-2000 ........................................... 0 TO ±2000 INPUT CURRENT RANGE .............................................................................. Amps. DC or AC peak. See Table CURRENT OVERLOAD.................................................... ±5000 Amps. DC continuous. FREQUENCY .................................................................... DC to 20KHz OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ±5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS LINEARITY ........................................................................ ±.5% FS DI DT CAPABILITY ........................................................... 25A per u-sec OUTPUT IMPEDANCE ..................................................... 100 Ohms max. TEMPERATURE COEFFICIENT...................................... ±0.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. 50mA max. REVERSE POLARITY PROTECTION ............................. 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -55° to +85°C STORAGE TEMPERATURE ............................................ -55° to +100°C OPERATING HUMIDITY................................................... 0% to 95% RH MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE ......................................................................... Operating: Sea level to 70,000 ft. RANDOM VIBRATION...................................................... Operating MIL-STD-810E Category 5, Proc. 1, 2 WO=0.012G Hz, Duration 1 hr., Figure 514.4-8 Suggested Vibration levels for high performance Aircraft 12.5 G-RMS composite min. DIELECTRIC STRENGTH................................................ 350V RMS terminals 1-4 to 5 & case INSULATION RESISTANCE ............................................ 100 M-Ohms min. ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. SHOCK .............................................................................. Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202. WEIGHT ............................................................................ 1.5 lbs. Max. TERMINAL IDENTIFICATION 12345-
Code Ident. No. 15948
A. B. C. D. E. F.
SUPPLY VOLTAGE (+) SUPPLY & OUTPUT (RTN) SUPPLY VOLTAGE (-) OUTPUT SIGNAL (+) CASE GROUND SPARE
MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.
AAC
Drawing Number
Rev.
700-944
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES 948
INPUT CURRENT PART NUMBER 948-600 ............................................. 0 TO ±600 948-800 ............................................. 0 TO ±800 948-1000 ........................................... 0 TO ±1000 948-1500 ........................................... 0 TO ±1500 948-2000 ........................................... 0 TO ±2000 INPUT RANGE .............................................................................. Amps. DC or AC peak. See Table CURRENT OVERLOAD.................................................... ±5000 Amps. DC continuous FREQUENCY .................................................................... DC to 20KHz OUTPUT VOLTAGE SIGNAL ........................................................... 0 to ±5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS LINEARITY ........................................................................ ±.5% FS DI DT CAPABILITY ........................................................... 25A per u-sec OUTPUT IMPEDANCE ..................................................... 100 Ohms max. TEMPERATURE COEFFICIENT...................................... ±0.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±1Vdc CURRENT DRAIN............................................................. 50mA max. REVERSE POLARITY PROTECTION .............................10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -20° to +70°C STORAGE TEMPERATURE ............................................ -45° to +85°C OPERATING HUMIDITY................................................... 0% to 95% RH INSULATION RESISTANCE ............................................ 100 M-Ohms min. ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. SHOCK .............................................................................. Operating: 50g, 11m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) WEIGHT ............................................................................ 1.5 lbs. max.
TERMINALS: 6-32 SCREWS, .325” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO .26” WIDE.
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (±)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-948
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES 909M4 REMOVEABLE YOKE TYPE INPUT RANGE MODEL NUMBER * 909M4-150........................................... 0 TO ±150 909M4-250........................................... 0 TO ±250 909M4-500........................................... 0 TO ±500 909M4-750........................................... 0 TO ±750 909M4-1000....................................... 0 TO ±1000 909M4-1500....................................... 0 TO ±1500 909M4-2000....................................... 0 TO ±2000 909M4-2500....................................... 0 TO ±2500 INPUT CURRENT RANGES........................................................ 0 to (FS) Full Scale, See Table CURRENT OVERLOAD................................................... 100 times FS OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE ...................................................................... TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE .................................................... OUTPUT SHORT-CIRCUIT DURATION.........................
0 to ±5Vdc FS ±1% FS 200 µ-sec. max. ±.05% FS/°C max. 100 Ohms max. Indefinite
POWER SUPPLY SUPPLY VOLTAGE ......................................................... ±15Vdc ±2Vdc SUPPLY BURDEN............................................................ +15Vdc 100mA max. -15Vdc 25mA max. PROTECTION .................................................................. Reverse Polarity Protection ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -25° to +75°C STORAGE TEMPERATURE RANGE ............................. -55° to +85°C ISOLATION....................................................................... Input/Output/Case (Supply & Output / Common) CASE MATERIAL ............................................................. Aluminum Casting FINISH .............................................................................. Black Anodize Finish WEIGHT ........................................................................... 18 oz.
BARRIER 1 2 3 4
TERMINAL IDENTIFICATION CONNECTOR OUTPUT SIGNAL (+) SUPPLY & OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) SPARE SPARE
A B C D E F
*NOTE: SERIES 909M4 NORMALLY SUPPLIED WITH 4 TERMINAL BARRIER STRIP. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR PT02E10-6P OR EQUIVALENT. ADD LETTER “C” AFTER MODEL NUMBER FOR CONNECTOR OPTION. (REFERENCE: CONNECTOR MATES WITH PT06A10-6S (SR) OR EQUIVALENT).
BARRIER MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS AND .375 CENTER DISTANCES. TERMINALS ACCEPT WIRE SIZE UP TO #16 AWG WITH LUGS TO .281 IN. WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-909M4
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
BIDIRECTIONAL CURRENT TRANSDUCER SERIES 9000 REMOVABLE YOKE TYPE PART NO.
INPUT RANGE
9000-150......................0 to ±150 9000-250......................0 to ±250 9000-500......................0 to ±500 9000-750......................0 to ±750
PART NO.
9000-1000................................ 0 to ±1000 9000-1500................................ 0 to ±1500 9000-2000................................ 0 to ±2000 9000-2500................................ 0 to ±2500
INPUT CURRENT RANGE................................................................... CURRENT OVERLOAD............................................................
See Table Unlimited Nondestructive
OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... RESPONSE (10 to 90%) ........................................................... OUTPUT IMPEDANCE ............................................................. TEMPERATURE COEFFICIENT.............................................. SHORT CIRCUIT DURATION..................................................
0 to ±5Vdc FS (Full Scale) ±1% FS 200 u-sec max. 100Ω max. ±0.05% FS/°C typ Continuous
POWER SUPPLY SUPPLY VOLTAGE ................................................................. CURRENT DRAIN..................................................................... REVERSE POLARITY .............................................................. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... ISOLATION ............................................................................... CASE MATERIAL ..................................................................... WEIGHT ...................................................................................
TERMINAL IDENTIFICATION BARRIER 1 2 3 4 5
A B C D E F
-25° to +75°C -55° to +85°C Input/Output/Case (Supply & Output Common) Molded Plastic Meets UL Flammability Rating 94V- 0 12 oz. max.
1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16AWG AND WIRE LUGS TO .250 IN. WIDE. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER C AFTER PART NUMBER FOR CONNECTOR OPTION.
AAC Code Ident. No. 15948
±15Vdc ±1Vdc 100mA max. at +15Vdc 25mA max. at -15Vdc No damage, 10uA current drain
NOTE:
CONNECTOR OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+15V) SUPPLY VOLTAGE (RTN) SUPPLY VOLTAGE (-15) SPARE
INPUT RANGE
Drawing Number
Rev.
700-9000
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER PART NUMBER S630-2500
INPUT MEASURING RANGE (CONTINUOUS) (TRANSIENT) .....
0 to ± 1000Adc FS (Full Scale) 1422A RMS (1 min) 1375A RMS (4 min) 1161A RMS (30 min) 2168A peak (5 sec.) 2514A tr (18 M-sec.)
OUTPUT CURRENT SIGNAL ................................. TURN RATIO ........................................... ACCURACY ............................................ LINEARITY .............................................. LOAD........................................................ RESPONSE .............................................
250uA per 1A Input 4000 to 1 0.5% FS (-25 to +70°C) ± 0.1% max. up to 630mA max. 5.5 Ohms max. 1M-sec. max.
POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... PROTECTION .........................................
±24Vdc ±1Vdc 650mA max. Reverse Polarity Protected
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE................... -40°C to +85°C SHOCK & VIBRATION ........................... IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ....................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 200 M-ohms @ 500Vdc DIELECTRIC STRENGTH ..................... 3.3Kv RMS 60Hz PRIMARY BAR VOLTAGE ..................... 2Kv RMS max. CASE........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 6.5 lbs. max.
NOTE: 1. MOULDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-005.RFP (XIL). 4 .RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.
TERMINAL IDENTIFICATION
1. 2. 3. 4. 5.
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (-) OUTPUT SPARE SPARE
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S630
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES 903B
PART NO.
INPUT CURRENT RANGE
903B-5 .........................0-5mA 903B-10 .......................0-10mA 903B-20 .......................0-20mA 903B-50 .......................0-50mA 903B-100 .....................0-100mA
PART NO.
INPUT CURRENT RANGE
903B-200 ................................. 0-200mA 903B-500 ................................. 0-500mA 903B-1A................................... 0-1A 903B-2A................................... 0-2A 903B-5A...................................0-5A
OUTPUT VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RIPPLE .............................................................................. 2% FS RMS max. IMPEDANCE ..................................................................... 1000 Ohms ±5%, 5mA to 1A range 500 Ohms ±5%, 2A 200 Ohms ±5%, 5A RESPONSE....................................................................... 50 m-sec. max. ( 10 to 90%) TEMPERATURE COEFFICIENT...................................... ±.04% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 50mAdc max. REVERSE POLARITY PROTECTION ............................. 10µA current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -55°C to +85°C STORAGE TEMPERATURE RANGE .............................. -60°C to +100°C INSULATION RESISTANCE ............................................ 100 M-ohms (all terminals to case) DIELECTRIC STRENGTH................................................ 350V RMS (all terminals to case) ALTITUDE ......................................................................... Operating sea level to 60,000 ft. VIBRATION ....................................................................... Operating - 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK .............................................................................. Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE ............................................... Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Meets spec. for any mounting position RIPPLE .............................................................................. 40mV reflected onto pass-thru line WEIGHT ............................................................................ 1.25 lbs. max.
TERMINAL IDENTIFICATION A. B. C. D. E. F.
Code Ident. No. 15948
SUPPLY VOLTAGE (+) SUPPLY AND SIGNAL (RTN) OUTPUT SIGNAL (+) SPARE SPARE CASE GROUND
AAC
Drawing Number
Rev.
700-903B
M
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES S767 CURRENT PART NUMBER RANGE S767-10 ...............................0 to 10mA S767-20 ...............................0 to 20mA S767-50 ...............................0 to 50mA S767-100 .............................0 to 100mA
PART CURRENT NUMBER RANGE S767-200 ........................... 0 to 200mA S767-250 ........................... 0 to 250mA S767-500 ........................... 0 to 500mA S767-1A............................. 0 to 1A
INPUT CURRENT RANGE.................................. See Table CURRENT OVERLOAD........................... 100Adc
TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY (RTN) C. OUTPUT SIGNAL (+) D. OUTPUT (RTN) E. CASE GROUND
OUTPUT VOLTAGE SIGNAL .................................. ACCURACY.............................................. OUTPUT IMPEDANCE ............................ RIPPLE ..................................................... TEMPERATURE COEFFICIENT............. LONG TERM STABILITY......................... RESPONSE (10 TO 90%)........................ PROTECTION..........................................
0 to +5Vdc FS (Full Scale) ± 1% FS (±50mV) 100 Ohms max. 1% FS (RMS) max. ±.02% FS/°C max. ±.2% FS/yr 50 m-sec max. Continuous Short ckt Without damage
POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN.................................... OVER VOLTAGE PROTECTION............ REVERSE POLARITY PROTECTION ....
22Vdc to 36Vdc 12mAdc Terminals A & B ±36Vdc without damage 10µA max. current drain
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -40° to +85°C STORAGE TEMPERATURE ................... -55° to +85°C HUMIDITY ................................................ 0% to 95% RH MOISTURE RESISTANCE ...................... MIL-STD-810, Method 507.1, Proc. I -5 ALTITUDE ................................................ Sea Level to 10 torr (Hard Vacuum) PYROSHOCK (PROTO FLIGHT) ........... 100Hz @ 50g +6dB/Oct to 1100g @ 1KHz flat to 10KHz VIBRATION (SINE) .................................. 0.06 In. D.A., 10 to 55 Hz (RANDOM) ............................................... Overall 37.9g’s 20 to 50 Hz 2 +12db/octave 0.084 to 3.0g /Hz. 3.0 flat. 130 to 300 Hz -6db/octave 2 3.0 to .6g /Hz. 300 to 1 flat 2 1500 to 2000 Hz -6db/octave 0.60 to 0.33g /Hz. INSULATION RESISTANCE .................. 100 M-Ohms min. @ 100Vdc ATTITUDE ................................................ Performs in any position. FINISH ...................................................... Fuse Tin Plate ENCAPSULANT....................................... Stycast 2850FT Cat 11 WEIGHT ................................................... .49lbs max.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S767-903
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES 936
PART NO.
INPUT CURRENT AMPS DC
936-10 ......................... 0 TO 10mA 936-20 ......................... 0 TO 20mA 936-50 ......................... 0 TO 50mA 936-100 ....................... 0 TO 100mA 936-200 ....................... 0 TO 200mA
INPUT CURRENT AMPS DC
PART NO.
936-250.................................... 0 TO 250mA 936-500................................... 0 TO 500mA 936-1A .................................... 0 TO 1A 936-2A .................................... 0 TO 2A 936-5A ..................................... 0 TO 5A
INPUT CURRENT RANGE (Adc) ................................................ TRANSIENT PROTECTION VOLTAGE OF THRU CABLE..................................... VOLTAGE TRANSIENT ............................................. CURRENT TRANSIENT ............................................ REFLECTED RIPPLE (THRU CABLE)............................ OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE (10 TO 90%) ................................................ RIPPLE ............................................................................. TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE (±5%)..........................................
See Table 35KV (with insulated cable) 500 Volts/u-sec 500 Amps/u-sec 40mV
0 to +5Vdc FS (Full Scale) ±1% FS (±50mV) 100 m-sec. max. 2% FS RMS max. ± 0.1% FS/°C max. 1000 Ohms (Ranges 10mA to 1A) 500 Ohms (Range 2A) 200 Ohms (Range 5A)
POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................ 75mAdc max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C INSULATION RESISTANCE............................................ 100 K-Ohms WEIGHT ........................................................................... 28 oz. max.
TERMINAL IDENTIFICATION A. B. C. D. E. F.
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT (RTN) SPARE OUTPUT (+) CASE GROUND
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-936
H
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES S218
PART NO.
INPUT CURRENT RANGE
S218-100..................... 0 TO 100mA S218-200..................... 0 TO 200mA S218-500..................... 0 TO 500mA
PART NO.
INPUT CURRENT RANGE
S218-1A ................................... 0 TO 1A S218-2A .................................. 0 TO 2A S218-5A .................................. 0 TO 5A
OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RIPPLE ............................................................................. IMPEDANCE.....................................................................
0 to +5Vdc FS (Full Scale) ±1% FS (±50mV) 2% FS RMS max. 1000 Ohms ±5%, 100mA to 1A range 500 Ohms ±5%, 2A 200 Ohms ±5%, 5A RESPONSE ...................................................................... 50 m-sec max. (10 to 90%) TEMPERATURE COEFFICIENT ..................................... ± .04%/°C max.
POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................ 65mAdc max. REVERSE POLARITY PROTECTION ............................ 10µA max. Current Drain- no damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -60°C to +100°C INSULATION RESISTANCE............................................ 100 M-Ohms (terminals 1,2,3,&4 to case) DIELECTRIC STRENGTH ............................................... 350V RMS (terminals 1,2,3,&4 to case) ALTITUDE......................................................................... Operating sea level to 60,000 ft. VIBRATION....................................................................... Operating - 0.06 in. D.A., 10 to 55Hz Method 201 of MIL-STD-202. SHOCK ............................................................................. Operating 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202. MOISTURE RESISTANCE .............................................. Will meet Method 106 of MIL-STD-202 and Method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY .................................................. 0 to 95% RH ATTITUDE ........................................................................ Meets spec. for any mounting position. RIPPLE ............................................................................. 40mV reflected onto pass-thru line. WEIGHT ........................................................................... 1.5 lbs. Max.
NOTE: MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT SIGNAL (RTN) OUTPUT SIGNAL (+) CASE GROUND
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S218-903
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 DC CURRENT TRANSDUCER SERIES S619 PART NUMBER
CURRENT RANGE
OVERLOAD
S619-3.5 S619-10
0 TO 3.5A 0 TO 10A
0 TO ±5A 0 TO ±15A
TRANSIENT 250 750
INPUT IMPEDANCE 5 1.75
INPUT CURRENT CURRENT RANGE .................................................................. See Table OVERLOAD .............................................................................. See Table continuous TRANSIENT OVERLOAD ........................................................ See Table sec / hr max. ISOLATION............................................................................... 500V RMS, 60Hz 1 min. INPUT IMPEDANCE................................................................. See Table milli-Ohms max. OUTPUT VOLTAGE SIGNAL................................................................... 0 to +3.5Vdc FS (Full Scale) ACCURACY (@ 25°C).............................................................. ± 2% FS (± 70mV) RESPONSE (0 to 90%) ............................................................ 1 m-sec OUTPUT IMPEDANCE ............................................................ 50 Ohms max. TEMPERATURE COEFFICIENT ............................................. .04% FS /°C max. LOAD IMPEDANCE.................................................................. 10K-Ohms min. POWER SUPPLY (PS) SUPPLY VOLTAGE ................................................................. +5Vdc ± .5Vdc CURRENT DRAIN.................................................................... 5mAdc max. POWER SUPPLY PROTECTION............................................ 0 to +12Vdc withstanding without damage
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5. 6.
INPUT CURRENT (+) INPUT CURRENT (-) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT SIGNAL (RTN) OUTPUT SIGNAL (+)
NOTE: TERMINALS 4 & 5 ARE ELECTRICALLY COMMON.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. -55° to +85°C STORAGE TEMPERATURE RANGE ..................................... -55° to +105°C OPERATING HUMIDITY .......................................................... 0% to 95% RH MOISTURE RESISTANCE ...................................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Procedure I of MIL-STD-810 -8 PRESSURE .............................................................................. 1 X 10 torr. SHOCK ..................................................................................... Operating: 50g, 11 m-sec half sine pulse (Method 213, Condition A of MIL-STD-202) VIBRATION .............................................................................. MIL-STD-202F Method 214 Test Condition G 26.4 GRMS overall DIELECTRIC STRENGTH ....................................................... 350V RMS dielectric withstanding voltage (Method 301 of MIL-STD-202) INSULATION RESISTANCE.................................................... 10 M-ohms min. (Method 302, Condition A of MIL-STD-202) ATTITUDE ................................................................................ Unit will perform as specified when mounted in any position. ENCAPSULANT ...................................................................... Stycast 2850FT Cat 11 CASE ........................................................................................ Diallylpthlalate MIL-M-14F,SDG WEIGHT ................................................................................... 1 oz. Typ.
NOTE: APPLY RTV 133 ADHESIVE (OR EQUIVALENT) 360° AROUND BOTTOM OF UNIT AFTER INSTALLING TO MEET ENVIRONMENTAL CHARACTERISTICS.
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-S619
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES 950 INPUT CURRENT RANGE (AMPS DC) MODEL NUMBER 950-10 ........................................................ 0 - 10 950-20 ........................................................ 0 - 20 950-30 ........................................................ 0 - 30 950-40 ........................................................ 0 - 40 950-50 ........................................................ 0 - 50 OUTPUT VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) ACCURACY....................................................................... ±0.5% FS (±25mV) for 20,30,40, & 50A models ±1% FS (±50mV) for 10A model RESPONSE (10 TO 90%)................................................. 10 m-sec. max. RIPPLE .............................................................................. 25mV (RMS) max. TEMPERATURE COEFFICIENT...................................... ±.02% FS/°C LONG TERM STABILITY.................................................. ±0.1% FS/yr OUTPUT IMPEDANCE ..................................................... 4000 ohms max. OUTPUT PROTECTION .................................................. Output terminals E & C will withstand ±250Vdc for 10m-sec, ±60Vdc continuously, short circuit POWER SUPPLY (PS) SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 70mAdc max. OVER VOLTAGE PROTECTION..................................... Terminals A & B withstand ±35Vdc without damage REVERSE POLARITY PROTECTION ............................. 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -25° to +85°C STORAGE TEMPERATURE RANGE .............................. -55° to +85°C DIELECTRIC STRENGTH................................................ 350 V RMS dielectric withstanding voltage (method 301 of MIL-STD-202) INSULATION RESISTANCE ............................................ 10 M-ohms min. (method 302, Condition A of MIL-STD-202) ALTITUDE ......................................................................... Operating: sea level to 60,00 ft. Non-operating: sea level to 120,000 ft. (method 105, Condition A of MIL-STD-202) VIBRATION ....................................................................... Operating: 0.06 inch D.A., 10 to 55 Hz (method 201 of MIL-STD-202) SHOCK .............................................................................. Operating: 50g, 11 m-sec half sine pulse (method 213, Condition A of MIL-STD-202) MOISTURE RESISTANCE ............................................... Will meet method 106 of MIL-STD-202 and Method 507.1, Procedure I of MIL-STD-810 OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position TERMINAL IDENTIFICATION A. B. C. D. E. F.
Code Ident. No. 15948
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT (RTN) SPARE OUTPUT (+) CASE GROUND
AAC
Drawing Number
Rev.
700-950
F
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES 913B
PART NO.
INPUT CURRENT RANGE
913B-10....................... 0 TO 10A 913B-15....................... 0 TO 15A 913B-20....................... 0 TO 20A 913B-25....................... 0 TO 25A 913B-30....................... 0 TO 30A
PART NO.
INPUT CURRENT RANGE
913B-35 ................................... 0 TO 35A 913B-40 .................................. 0 TO 40A 913B-50 .................................. 0 TO 50A 913B-75 .................................. 0 TO 75A 913B-100 ................................ 0 TO 100A
INPUT CURRENT RANGE ............................................................................. See Table OVER CURRENT (UNLIMITED)...................................... Nondestructive/nonlatching Saturated Output OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE ( 10 TO 90%) ............................................... IMPEDANCE.....................................................................
0 to +5Vdc FS (Full Scale) ±1% FS 1 m-sec. max. 100Ω max. for 10A to 50A ranges 275Ω for 75A to 100A ranges RIPPLE ............................................................................. 10mV RMS max. TEMPERATURE COEFFICIENT ..................................... ±0.02% FS/°C max. OUTPUT PROTECTION.................................................. Terminals D & E will withstand ±32Vdc or short circuit
POWER SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................ 75mA max. REVERSE POLARITY PROTECTION ............................ 10µA max. Current drain without damage
TERMINAL IDENTIFICATION A. B. C. D. E. F.
Code Ident. No. 15948
SPARE SPARE +28Vdc D.C. COMMON 0 TO +5V OUTPUT CASE GROUND
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 INSULATION RESISTANCE............................................ 200 M-ohms min. MIL-STD-202 Method 302 Test Condition A ALTITUDE......................................................................... Operating sea level to 100,000 ft., MIL-STD-202, Method 105, Condition D VIBRATION....................................................................... Operating 0.06 in. D.A., 10Hz to 55 Hz MIL-STD-202 Method 201 SHOCK ............................................................................. Operating 50 g, 11 m-sec MIL-STD-202 Method 213, Condition A MOISTURE RESISTANCE .............................................. MIL-STD-202 Method 106 OPERATING HUMIDITY .................................................. 0% to 95% RH ATTITUDE ........................................................................ Meets spec. for any mounting position WEIGHT ........................................................................... 12 oz. max.
AAC
Drawing Number
Rev.
700-913B
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(6316) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES 913A PART NO.
INPUT CURRENT
913A-10....................... 0 to 10A 913A-20....................... 0 to 20A 913A-25....................... 0 to 25A 913A-30....................... 0 to 30A
PART NO.
INPUT CURRENT
913A-40 ................................... 0 to 40A 913A-50 .................................. 0 to 50A 913A-75 .................................. 0 to 75A 913A-100 ................................ 0 to 100A
INPUT RANGE ............................................................................. See Table OVER CURRENT (UNLIMITED)...................................... Nondestructive/nonlatching Saturated Output OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE(10 TO 90%) ................................................. IMPEDANCE.....................................................................
0 to +5Vdc FS (Full Scale) ±1% FS 1 m-sec max. 100Ω for 10A to 50A ranges 1000Ω for 75A to 100A ranges RIPPLE ............................................................................. 10mV RMS max. TEMPERATURE COEFFICIENT ..................................... ±0.02% FS/°C max. for 10A & 50a RANGES ±0.04% for 75A & 100A ranges OUTPUT PROTECTION.................................................. Terminals D & E will withstand +32Vdc or short circuit
POWER SUPPLY SUPPLY VOLTAGE ......................................................... +28Vdc ±4Vdc CURRENT DRAIN............................................................ 75mA max. REVERSE POLARITY PROTECTION ............................ 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 INSULATION RESISTANCE............................................ 200M-Ohms min. MIL-STD-202 Method 302 Test Condition A ALTITUDE......................................................................... Operating sea level to 100,000 ft. MIL-STD-202, Method 105, Condition D VIBRATION....................................................................... Operating 0.06 in D.A., 10Hz to 55Hz MIL-STD202, Method 201 SHOCK ............................................................................. Operating 50g 11 m-sec MIL-STD-202, Method 213, Condition A MOISTURE RESISTANCE .............................................. MIL-STD-202, Method 106 OPERATING HUMIDITY .................................................. 0 to 95% RH ATTITUDE ........................................................................ Meets specification for any mounting position WEIGHT ........................................................................... 9 oz. max. TERMINAL IDENTIFICATION A. SPARE B. SUPPLY VOLTAGE (RTN) C. SUPPLY VOLTAGE (+) D. OUTPUT SIGNAL (RTN) E. OUTPUT SIGNAL (+) F. CASE GROUND TERMINALS B & D ARE COMMON
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-913A
T
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES S770 PART CURRENT NUMBER RANGE S770-20 .........................0 to 20 S770-25 .........................0 to 25 S770-30 .........................0 to 30 S770-40 .........................0 to 40
PART CURRENT NUMBER RANGE S770-50…………………0 to 50 S770-60…………………0 to 60 S770-70…………………0 to 70 S770-100……………….0 to 100
INPUT RANGE .............................................................................. OVERLOAD CONTINUOUS............................................. FREQUENCY RANGE ......................................................
See Table ±2000Adc DC to 350Hz
OUTPUT VOLTAGE SIGNAL ........................................................... ACCURACY....................................................................... RESPONSE (10 to 90%) ................................................... OUTPUT IMPEDANCE ..................................................... LOAD RESISTANCE ........................................................ TEMPERATURE COEFFICIENT...................................... OUTPUT PROTECTION ..................................................
0 to+5Vdc ±1% FS 1 m sec. 10 Ohms 10k Ohms min ±.02%FS per °c max. Short Circuit
POWER SUPPLY SUPPLY VOLTAGE ......................................................... CURRENT DRAIN............................................................. PROTECTION................................................................... TRANSIENT PROTECTION.............................................
+12Vdc to +36Vdc 10mAdc max. Reverse polarity protected ±60V (T<5mS)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -40° to +85°C STORAGE TEMPERATURE RANGE .............................. -40° to +85°C ISOLATION ....................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE ............................................ 500 M-Ohms @ 500Vdc CASE MATERIAL.............................................................. Molded Plastic meets UL flammability rating 94V-O WEIGHT ........................................................................... 10 oz. Max.
TERMINAL IDENTIFICATION 1. 2.
3. 4.
SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT (RTN) OUTPUT SIGNAL (+)
TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S770
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .06 .XXX ± .030
DC CURRENT TRANSDUCER SERIES 920 4 TO 20 mA 2 WIRE LOOP POWER CLAMP ON PART NO 920-50 920-75 920-100 920-125
TERMINAL IDENTIFICATION PIN 1 : POWER PIN 2 : RTN PIN 3 : N.C. PIN 4 : N.C. PIN 5 : N.C.
CURRENT RANGE 0 TO 50Adc 0 TO 75Adc 0 TO 100Adc 0 TO 125Adc
INPUT RANGE ........................................................................... OVERLOAD CONTINUOUS........................................... FREQUENCY RANGE....................................................
See table ±5000Adc DC to 35Hz
OUTPUT CURRENT SIGNAL ........................................................ ACCURACY (Over Temperature Range) ...................... RESPONSE (10 to 90%) ................................................ LOAD RESISTANCE (RL) .............................................. LOAD RESISTANCE RANGE ....................................... CURRENT SIGNAL @ OVERLOAD............................... PROTECTION ................................................................
4 to 20mAdc See table & Note 1 %FS (Full Scale) 10 m sec. 250 Ohms Nominal 0 to 300 Ohms 24 mAdc typ. Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... SUPPLY VOLTAGE RANGE .......................................... TRANSIENT PROTECTION ...........................................
+24Vdc Nominal 4 to 24mAdc +18 to 28Vdc ±40V (T<5mS)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE......................... -40° to +85°C STORAGE TEMPERATURE RANGE ............................ -45° to +85°C ISOLATION..................................................................... Input to output 2KV rms 60Hz/1min. INSULATION RESISTANCE .......................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O WEIGHT ......................................................................... 14 oz. Max. FINISH ............................................................................ Blue Textured Pantone No. 294C NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. 2: Insert tool and press to release. (Recommended Tool : Screwdriver, 3/16 standard tipped)
AAC Code Ident. No. 15948
ACCURACY 1.25% 1.0% 1.0% 1.0%
Drawing Number
Rev.
700-920
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SPLIT CORE PART. NO.
SELECTABLE MEAS. RANGE
OUTPUT SIGNAL
DCT-05-100 DCT-05-200 DCT-05-300 DCT-05-400 DCT-20-100 DCT-20-200 DCT-20-300 DCT-20-400
50, 75, 100A 100, 150, 200A 150, 225, 300A 200, 300, 400A 50, 75, 100A 100, 150, 200A 150, 225, 300A 200, 300, 400A
0-5VDC 0-5VDC 0-5VDC 0-5VDC 4-20mA 4-20mA 4-20mA 4-20mA
SPECIFICATIONS Output Signal Output Output Limit Accuracy Repeatability Response Time Frequency Range Power Supply Power Consumption Loading
4-20mA or 0-5VDC 4-20mA: 44mA 0-5vdc:: 13VDC 1.0% FS 1.0%FS 100mS (to 90% of step change) DC 20-50VDC, 22-38VAC power input and output signal are not isolated. 2VA 4-20mA:: 650Ω max.
0-5VDC: 250KΩ for rated accuracy; 25KΩ, add 1% error. Isolation Voltage Linearity Current Ranges Sensing Aperture Case Environmental
3KV (monitored line output) 0.75% FS Field selectable ranges from 0-400A. 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -4 to 122° F (-20 to 50° C), 0-95% RH, non-condensing
DCT-
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- DCT
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES S728B AAC PART NUMBER S728B-50 S728B-100 S728B-150 S728B-200 S728B-250 S728B-300 S728B-400
TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT SIGNAL (RTN) D. OUTPUT SIGNAL (+) E. CASE GROUND
INPUT CURRENT RANGE 0 to 50Adc 0 to 100Adc 0 to 150Adc 0 to 200Adc 0 to 250Adc 0 to 300Adc 0 to 400Adc
OUTPUT ACCURACY (SEE NOTE 1) @25°C 0 to 70°C -55to85°C ±0.5% ±0.8% ±1.5% ±0.5% ±0.6% ±1.0% ±0.5% ±0.6% ±1.0% ±0.5% ±0.6% ±0.8% ±0.5% ±0.6% ±0.8% ±0.4% ±0.5% ±0.8% ±0.3% ±0.4% ±0.6%
SUPPLY CURRENT DRAIN 40mA 40mA 50mA 50mA 65mA 80mA 110mA
INPUT CURRENT RANGE .................................................... CURRENT OVERLOAD..........................
See Table 5000Adc Continuous (Nonlatching/Saturated Output)
OUTPUT CURRENT SIGNAL................................. ACCURACY............................................. LINEARITY............................................... BANDWIDTH........................................... RESPONSE TIME ( 10 to 90%)............... OUTPUT IMPEDANCE ...........................
0 to 5Vdc FS (Full Scale) % FS See Table & Note 1 ±0.1% FS. DC TO 350KHZ 1 u-sec. 50 Ohms max.
POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN................................... REVERSE POLARITY PROTECTION ...
28Vdc ±4Vdc See Table 100uA Current Drain Without Damage
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............... -55 to +85°C STORAGE TEMPERATURE .................. -55 to +90°C OPERATING HUMIDITY ......................... 0% to 95% RH MOISTURE RESISTANCE .................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE ............................................... Operating sea level to 60,000 ft. Non-operating - sea level to 120,000 ft. (Method 105, Condition A of MIL-STD-202) SHOCK ................................................... Non-Operating - 50g, 11 m-sec half sine pulse (Method 213 Condition A of MIL-STD-202) 2 RANDOM VIBRATION ............................ Operating MIL-STD-810E Cat.5, Proc.1, WO=0.012G /HZ, Duration 1 hr., Figure 514.4-8 Suggested Vibration Levels for High Performance Aircraft 12.5G-RMS Min. DIELECTRIC STRENGTH ..................... 350V RMS Terminals A-D to E & Case INSULATION RESISTANCE .................. 100 M-Ohms Min. FINISH .................................................... Fuse Tin Plate ALTITUDE................................................ Unit will perform as specified when mounted in any position WEIGHT ................................................. 0.57 lbs. max.
NOTE: Specified accuracy includes the combined worst case effects of Zero Offset, Hysteresis, Supply Swings and Current Cable Positioning
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S728B-952
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES 952 AAC PART NUMBER 952-50 952-100 952-150 952-200 952-250 952-300 952-400 952-500 952-600 952-750
TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT SIGNAL (RTN) D. SPARE E. OUTPUT SIGNAL (+) F. CASE GROUND
INPUT CURRENT RANGE 0 to 50Adc 0 to 100Adc 0 to 150Adc 0 to 200Adc 0 to 250Adc 0 to 300Adc 0 to 400Adc 0 to 500Adc 0 to 600Adc 0 to 750Adc
OUTPUT ACCURACY OUTPUT (SEE NOTE 1) IMPEDANCE @25°C 0 to 70°C -55to85°C OHMS ±0.5% ±0.8% ±1.5% 100 ±0.5% ±0.6% ±1.0% 100 ±0.5% ±0.6% ±1.0% 70 ±0.5% ±0.6% ±0.8% 50 ±0.5% ±0.6% ±0.8% 40 ±0.4% ±0.5% ±0.8% 33 ±0.3% ±0.4% ±0.6% 50 ±0.3% ±0.4% ±0.6% 40 ±0.3% ±0.4% ±0.6% 33 ±0.3% ±0.4% ±0.6% 26
INPUT CURRENT RANGE .................................................... See Table CURRENT OVERLOAD.......................... 5000 Adc Continuous ( Nonlatching/Saturated Output) OUTPUT VOLTAGE SIGNAL.................................. 0 to +5 Vdc FS (Full Scale) ACCURACY............................................. % FS See Table & Note 1 LINEARITY............................................... ±0.1% FS DI/DT ACCURATELY FOLLOWED ........ 100 A/u-sec. BANDWIDTH........................................... DC TO 100KHZ RESPONSE TIME ................................... <1 u-sec. OUTPUT IMPEDANCE ........................... See Table POWER SUPPLY SUPPLY VOLTAGE ................................ 28Vdc ±4Vdc CURRENT DRAIN................................... See Table REVERSE POLARITY PROTECTION ... 10uA Current Drain Without Damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE............... -55 to +85°C STORAGE TEMPERATURE .................. -55 to +85°C OPERATING HUMIDITY ......................... 0% to 95% RH MOISTURE RESISTANCE .................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE ............................................... Operating sea level to 60,000 ft. Non-operating - sea level to 120,000 ft. (Method 105, Condition A of MIL-STD-202) SHOCK ................................................... Non-Operating - 50g, 11 m-sec half sine pulse (Method 213 Condition A of MIL-STD-202) 2 RANDOM VIBRATION ............................ Operating MIL-STD-810E Cat.5, Proc.1, WO=0.012G /HZ, Duration 1 hr., Figure 514.4-8 Suggested Vibration Levels for High Performance Aircraft 12.5G-RMS Min. DIELECTRIC STRENGTH ..................... 350V RMS Terminals 1-5 to 6 & Case INSULATION RESISTANCE .................. 100 M-Ohms Min. ALTITUDE................................................ Unit will perform as specified when mounted in any position WEIGHT ................................................. 1.21 lbs. max.
NOTE: Specified accuracy includes the combined worst case effects of Zero Offset, Hysteresis, Supply Swings and Current Cable Positioning
AAC Code Ident. No. 15948
SUPPLY CURRENT DRAIN 40mA 40mA 60mA 65mA 80mA 100mA 75mA 100mA 140mA 185mA
Drawing Number
Rev.
700-952
K
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES S347 REMOVABLE YOKE TYPE
PART NO.
INPUT CURRENT RANGE
S347-100..................... 0 TO 100A S347-150..................... 0 TO 150A S347-200..................... 0 TO 200A S347-225..................... 0 TO 225A S347-250..................... 0 TO 250A S347-300..................... 0 TO 300A
INPUT CURRENT RANGE
PART NO.
S347-500 ................................. 0 TO 500A S347-750 ................................ 0 TO 750A S347-1000 .............................. 0 TO 1000A S347-1500 .............................. 0 TO 1500A S347-2000 ............................... 0 TO 2000A S347-2500 ............................... 0 TO 2500A S347-5000 ............................... 0 TO 5000A
INPUT CURRENT RANGE .......................................................... 0 to Full Scale (FS) See Table CURRENT OVERLOAD................................................... 100 times FS OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE ...................................................................... TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE ....................................................
0 to +5Vdc (FS) ±1% FS (±50mV) 200 µ-sec. max. ± .05% FS/°C 100 Ohms max.
SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc SUPPLY BURDEN............................................................ 100mA max. PROTECTION .................................................................. Reverse Polarity Protection ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -25°C to +75°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C ISOLATION....................................................................... Input/Output/Case (Supply & Output common) CASE MATERIAL ............................................................. Aluminum Casting FINISH .............................................................................. Black Anodize Finish WEIGHT ........................................................................... 18 oz.
TERMINAL IDENTIFICATION CONNECTOR A B C D E F
SIGNAL OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE
MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS AND .375 CENTER DISTANCES. TERMINALS ACCEPT WIRE SIZE UP TO #16 AWG. WITH LUGS TO .281 IN. WIDE.
Code Ident. No. 15948
BARRIER 1 2 3 4
NOTES: 1. SERIES S347-909 NORMALLY SUPPLIED WITH 4 TERMINAL BARRIER STRIP AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER -C AFTER PART NUMBER FOR CONNECTOR OPTION. (REFERENCE: CONNECTOR MATES WITH PT06A-10-6S (SR) OR EQUIVALENT.
AAC
Drawing Number
Rev.
700-S347-909
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .06 .XXX ± .030
DC CURRENT TRANSDUCER SERIES 921 4 TO 20 mA 2 WIRE LOOP POWER CLAMP ON PART NO 921-200 921-250 921-300 921-400 921-500 921-750 921-1000 921-1500 921-2000
TERMINAL IDENTIFICATION PIN 1 : POWER PIN 2 : RTN PIN 3 : N.C. PIN 4 : N.C PIN 5: N.C.
CURRENT RANGE 0 TO 200Adc 0 TO 250Adc 0 TO 300Adc 0 TO 400Adc 0 TO 500Adc 0 TO 750Adc 0 TO 1000Adc 0 TO 1500Adc 0 TO 2000Adc
INPUT RANGE ........................................................................... OVERLOAD CONTINUOUS........................................... FREQUENCY RANGE....................................................
See table ±5000Adc DC to 35Hz
OUTPUT CURRENT SIGNAL ........................................................ ACCURACY (Over Temperature Range) ...................... RESPONSE (10 to 90%) ................................................ LOAD RESISTANCE (RL) .............................................. LOAD RESISTANCE RANGE ....................................... CURRENT SIGNAL @ OVERLOAD............................... PROTECTION ................................................................
4 to 20mAdc See table & Note 1 %FS (Full Scale) 10 m sec. 250 Ohms Nominal 0 to 300 Ohms 24 mAdc typ. Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... SUPPLY VOLTAGE RANGE .......................................... TRANSIENT PROTECTION ...........................................
+24Vdc Nominal 4 to 24mAdc +18 to 28Vdc ±40V (T<5mS)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE......................... -40° to +85°C STORAGE TEMPERATURE RANGE ............................ -45° to +85°C ISOLATION..................................................................... Input to output 2KV RMS 60Hz/1min. INSULATION RESISTANCE .......................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O WEIGHT ......................................................................... 14 oz. Max. FINISH ............................................................................ Blue Textured Pantone No. 294C NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. 2: Insert tool and press to release. (Recommended Tool : Screwdriver, 3/16 standard tipped)
AAC Code Ident. No. 15948
ACCURACY 1.5% 1.5% 1.5% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
Drawing Number
Rev.
700-921
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES S444 REMOVABLE YOKE TYPE
PART NO.
INPUT CURRENT RANGE
S444-200 .....................0 TO 200 S444-225 .....................0 TO 225 S444-250 .....................0 TO 250 S444-300 .....................0 TO 300 S444-500 .....................0 TO 500
PART NO.
INPUT CURRENT RANGE
S444-750 ................................. 0 TO 750 S444-1000 ............................... 0 TO 1000 S444-1500 ............................... 0 TO 1500 S444-2000 ............................... 0 TO 2000 S444-2500 ............................... 0 TO 2500
INPUT CURRENT RANGE........................................................... See Table CURRENT OVERLOAD.................................................... Unlimited Nondestructive OUTPUT VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RESPONSE (10 TO 90%)................................................. 200 u-sec. max. OUTPUT IMPEDANCE ..................................................... 100 Ohms max. TEMPERATURE COEFFICIENT...................................... ± .05% FS/°C max. SHORT CIRCUIT DURATION.......................................... Continuous OUTPUT LOAD................................................................. 1 K-Ohms min. SUPPLY SUPPLY VOLTAGE ......................................................... 28Vdc ±4Vdc CURRENT DRAIN............................................................. 100mA max. REVERSE POLARITY ...................................................... No damage, 10µA current drain max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -25°C to +75°C STORAGE TEMPERATURE RANGE .............................. -55°C to +85°C ISOLATION ....................................................................... Input/Output/Case (Supply & Output common) CASE MATERIAL.............................................................. GE Lexan (Molded plastic) meets UL flammability rating 94V-0 WEIGHT ............................................................................ 12 oz. max.
TERMINAL IDENTIFICATION CONNECTOR A B C D E F
OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE
BARRIER 1 2 3 4 5
NOTES: 1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16 AWG AND WIRE LUGS TO .250 IN. WIDE. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER -C AFTER PART NUMBER FOR CONNECTOR OPTION.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S444-909
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT TRANSDUCER SERIES S465 REMOVABLE YOKE TYPE PART NO. S465-150.............. S465-250.............. S465-500.............. S465-750..............
INPUT RANGE
PART NO.
INPUT RANGE
0 to 150Adc 0 to 250Adc 0 to 500Adc 0 to 750Adc
S465-1000 .............................. S465-1500 .............................. S465-2000 .............................. S465-2500 ..............................
0 to 1000Adc 0 to 1500Adc 0 to 2000Adc 0 to 2500Adc
INPUT RANGE .................................................... OVERLOAD CONTINUOUS ...................
Adc See Table Unlimited (Nondestructive Nonlatching/ Saturated Output)
OUTPUT CURRENT SIGNAL................................. ACCURACY............................................. TEMPERATURE COEFFICIENT ............ RESPONSE (10 to 90%) ......................... LOAD RESISTANCE .............................. LOAD RESISTANCE RANGE................. CURRENT SIGNAL @ OVERLOAD.......
4 to 20mAdc FS (Full Scale) ± 1% FS or ±0.2mA max. ± 0.05% FS / °C max. 200uS max. 250 Ohms Nominal 0 to 300 Ohms 30mA TYP.
POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN................................... PROTECTION .........................................
16 to 26Vdc 30mA plus I load Reverse Polarity Protected
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE. -25° to +75°C STORAGE TEMPERATURE RANGE .... -40° to +85°C ISOLATION.............................................. Input/Output/Case INSULATION RESISTANCE................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE........... 1.5KV max. (5KV max. with insulated cable) CASE ...................................................... Molded Plastic (GE Lexan) Meets UL Flammability Rating 94 WEIGHT ................................................. 18 oz. Max.
NOTE: HOUSING AND POT HOLES SEALED MAKING TRANSDUCER WATER SPRAY RESISTANT. END USER MUST COAT TERMINAL BLOCK WITH SILICONE TO PREVENT CORROSION. NOTE: TERMINAL IDENTIFICATION 1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16AWG AND WIRE LUGS TO .250 IN. WIDE. AVALIABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER C AFTER PART NUMBER FOR CONNECTOR OPTION.
Code Ident. No. 15948
BARRIER 1 2 3 4 5
CONNECTOR OUTPUT (+) A OUTPUT (RTN) B SUPPLY VOLTAGE (+) C SUPPLY VOLTAGE (RTN) D SPARE E SPARE F
AAC
Drawing Number
Rev.
700-S465-909
F
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03 .010
.XXX ±
DC CURRENT TRANSDUCER PART NUMBER S646S646- 1000 INPUT RANGE NOMINAL ..................................................................... 0 to 1000Adc Full Scale OVERLOAD................................................................................ 0 to 5000Adc VOLTAGE ................................................................................... 2500Vdc OUTPUT VOLTAGE SIGNAL .................................................................... SCALE FACTOR ........................................................................ ACCURACY................................................................................ RESPONSE TIME....................................................................... OUTPUT IMPEDANCE............................................................... LOAD .......................................................................................... SHORT CIRCUIT ........................................................................ TRANSIENT PROTECTION ......................................................
0 to +6Vdc 6mV per Amp ±2% FS (±20Adc) over temperature range 200 µ-sec. max. 15Ω Max. 50K to ∞ Protected t ≤ 1ms ±200V
POWER SUPPLY SUPPLY VOLTAGE ................................................................... +15Vdc (±0.4Vdc) with source impedance 0 to 50 Ohms POWER CONSUMPTION .......................................................... 0.5 W max. PROTECTION............................................................................. Reverse Polarity Protected TRANSIENT PROTECTION ....................................................... t ≤ 100ms +60V/-50V ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE.................................................. -30° C to +60°C STORAGE TEMPERATURE...................................................... -55°C to +85°C SHOCK........................................................................................ Operating 50g 11m-sec MIL-STD-202 Method 213 Condition A VIBRATION................................................................................. Operating 0.06 inch D.A. 10Hz to 55Hz MIL-STD-202 Method 201 HUMIDITY................................................................................... 0 to 95% RH Operating INSULATION RESISTANCE ...................................................... 500 M-Ohms @ 500Vdc DIELECTRIC STRENGTH.......................................................... 2500 DC ATTITUDE................................................................................... Performs in any position CASE MATERIAL....................................................................... Molded plastic (GE LEXAN) meets UL Flammability rating 94V-0 ENCAPSULANT ......................................................................... STYCAST 2850FT CAT 24LV WEIGHT ...................................................................................... 12 oz. max.
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+15V) SUPPLY VOLTAGE (RTN) SPARE
NOTE: 1. SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS AND INT. TOOTH LOCKWASHERS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16AWG AND WIRE LUGS TO .250 IN. WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- S646
G
AAC AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT LEVEL DETECTOR SERIES 901B PART NO.
INPUT CURRENT
901B-20 .......................0 to 20mA 901B-50 .......................0 to 50mA 901B-100 .....................0 to 100mA 901B-200 .....................0 to 200mA 901B-250 .....................0 to 250mA
PART NO.
INPUT CURRENT
901B-500 ................................. 0 to 500mA 901B-1A................................... 0 to 1A 901B-2A................................... 0 to 2A 901B-5A................................... 0 to 5A
INPUT CURRENT RANGE (Adc) ................................................. See Table TRANSIENT PROTECTION VOLTAGE OF THRU CABLE ...........................................30KV (with insulated cable) VOLTAGE TRANSIENT.................................................... 500 Volts/u-sec. CURRENT TRANSIENT ................................................... 250 Amps/u-sec. CURRENT CAPABILITY................................................... 250 Amps for 100 m-sec. OUTPUT “A” VOLTAGE SIGNAL ........................................................... 0 to +5Vdc FS (Full Scale) LOAD ................................................................................. 5K Ω ±1% ACCURACY....................................................................... ±1% FS (±50mV) RIPPLE .............................................................................. 3% FS RMS max. RESPONSE (10 TO 90%)................................................. 50 m-sec. max. TEMPERATURE COEFFICIENT...................................... ±0.1% FS/°C max. OUTPUT “B” VOLTAGE SIGNAL ........................................................... 18Vdc @ 10mA (Above set point) <0.05Vdc (Below set point) SET POINT........................................................................ Adjustable from 70% FS to 110% FS SET POINT REPEATABILITY .......................................... ±2% FS RESPONSE TIME............................................................. 50 m-sec max. POWER SUPPLY (PS) SUPPLY VOLTAGE ......................................................... 24Vdc ±3Vdc CURRENT DRAIN............................................................. 75mA max. REVERSE POLARITY PROTECTION ............................. 10µA current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -20°C to +70°C STORAGE TEMPERATURE RANGE .............................. -55°C to +85°C INSULATION RESISTANCE ............................................ 100 K-ohms (all terminals to case) RIPPLE .............................................................................. 40mV reflected onto pass-thru line WEIGHT ............................................................................ 1.75 lbs. Max.
TERMINAL IDENTIFICATION A. SUPPLY VOLTAGE (+) B. SUPPLY VOLTAGE (RTN) C. OUTPUT A (+) D. OUTPUT A (RTN) E. OUTPUT B (+) * F. OUTPUT B (RTN)
Code Ident. No. 15948
* NOTE: FOR BARRIER OPTION ONLY, TERMINALS “A-E” AS SHOWN. OUTPUT A (RTN) AND OUTPUT B (RTN) ARE COMMON AT TERMINAL D.
AAC
Drawing Number
Rev.
700-901B
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT LEVEL DETECTOR SERIES S204 PART NO.
TRIP POINT
S204-100..................... 100mA S204-150..................... 150mA S204-350..................... 350mA S204-550..................... 550mA S204-1......................... 1A
PART NO.
TRIP POINT
S204-1.2 ................................. 1.2A S204-2 ..................................... 2A S204-3 .................................... 3A S204-5 .................................... 5.75A
INPUT RANGE ............................................................................. 0 to 10Amps D.C. TRIP POINT...................................................................... See Table OUTPUT RELAY CONTACT (SPST) .............................................. CONTACT RATING ......................................................... TRIP POINT ACCURACY ................................................ TRIP POINT REPEATABILITY ........................................ RESET .............................................................................. RESPONSE TIME ............................................................ ISOLATION.......................................................................
Energized at & above set point 1 Amp @ 28V and 5V RMS ±4% set point ± 2% of set point Automatic when current falls 15% below trip point 3 m-sec max. 350V RMS @ sea level
POWER SUPPLY SUPPLY VOLTAGE ......................................................... 22.8 to 30.4Vdc CURRENT DRAIN............................................................ 70mA max. REVERSE POLARITY PROTECTION ............................ 10µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -20°C to +70°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 INSULATION RESISTANCE............................................ 200 M-Ohms min. MIL-STD-202 Method 302 Test Condition A ALTITUDE......................................................................... Operating sea level to 100,000 ft., MIL-STD-202, Method 105, Condition A VIBRATION....................................................................... Operating 0.06 inch D.A., 10Hz to 55Hz MIL-STD-202, Method 201 SHOCK ............................................................................. Operating 50g 11m-sec MIL-STD-202, Method 213, Condition A MOISTURE RESISTANCE .............................................. MIL-STD-202, Method 106 OPERATING HUMIDITY .................................................. 0 to 95% RH ATTITUDE ........................................................................ Meets specification for any mounting position WEIGHT ........................................................................... 12 oz. max.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S204-800
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT LEVEL DETECTOR SERIES S58-800
CURRENT ACTUATION LEVELS ZERO CURRENT INPUT ......................................... CONDITION A 200mA to 10A Max. .................................................. CONDITION B
OUTPUT CONDITION A (ZERO CURRENT) ......................... 1K-Ohm max. between terminal 1 & 2 CONDITION B (ABOVE 200mA).............................. 40K-Ohm min. between terminal 1 & 2
EXCITATION VOLTAGE VOLTAGE.................................................................. 28Vdc Nominal 22.8 to 30.4 Vdc min. to max. voltage. RESPONSE .............................................................. 1 m-sec. max. ADJUSTMENTS ....................................................... None RESET FROM COND. B TO COND. A ................... Automatic when current levels falls within 0 to 200 mA. ENVIRONMENTAL TEMPERATURE RANGE ........................................ 0°C to 70°C
BARRIER BLOCK TERMINAL 6-23 TERMINAL SCREWS.
TERMINAL IDENTIFICATION 1. 2. 3.
+28Vdc EXCITATION VOLTAGE OUTPUT EXCITATION RETURN AND OUTPUT RETURN (DC COMMON)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S58-800
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 DC CURRENT LEVEL DETECTOR PART NUMBER S754-1
INPUT RANGE .................................................... 0 to +20Adc (Continuous) TRIP POINT SETTING SET POINT............................................... 625mAdc TRIP POINT REPEATABILITY ................ 5% TRIP POINT RESPONSE TIME ............ 100 m-sec. ADJUSTMENT RANGE * ........................ Field Adjustable From 500mAdc to 1Adc RESET POINT SETTING RESET ..................................................... Manual by depressing reset switch (S1) . OUTPUT RELAY (Solid State) RELAY CONTACT (SPST) ...................... CONTACT RESISTANCE........................ DIELECTRIC STRENGTH ...................... CURRENT RATING ................................ OPEN CIRCUIT VOLTAGE……………… INDICATOR..............................................
Contacts Open at and above trip point On 1.5 Ohms Max, Off 100M Ohms Min. 2.5KV RMS 60Hz 600mAdc max. 55Vdc Max. LED on at & above trip point
POWER SUPPLY SUPPLY VOLTAGE ................................ +25 to 45Vdc CURRENT DRAIN.................................... 40mA max. TRANSIENT PROTECTION.................... ±60V Peak (30sec.); ±100V Peak (2m sec.) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -40°C to +85°C STORAGE TEMPERATURE ................... -45°C to +85°C OPERATING HUMIDITY ........................ 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ...................... 2.5Kv RMS 60Hz PRIMARY CONDUCTOR VOLTAGE ..... 1000Vdc max. CASE ........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 12 oz. max.
*
FACTORY SET AT 750mA
NOTE: 1. MOLDED TERMINAL BLOCK WITH 8-32 TERMINAL SCREWS, 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 12 AWG. TORQUE 9 IN-LB MAX. 2. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S754
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
D.C. CURRENT LEVEL DETECTOR PART NUMBER S201-800
TRIP POINT (AS CURRENT DECREASES) ........................................ 1Amp DC ±0.15Amp TRIP POINT REPEATABILITY .............................................................. ±0.02 Amps, DC RESET.................................................................................................... Automatic when input current rises approximately 0.15 A above trip point CURRENT RANGE................................................................................ 0 to 100 Amps, DC OUTPUT.................................................................................................SPDT Relay Contacts CONTACT RATING ............................................................................... 1A Resistive @ 28Vdc or 5V 400Hz 200mA Inductive. 100mA Lamp. OUTPUT ISOLATION ............................................................................ 350V RMS at sea level EXCITATION .......................................................................................... 28Vdc, Nominal @ 70mA, max. RESPONSE............................................................................................ 200 m-sec max. TEMPERATURE RANGE ...................................................................... -55°C to +70°C WEIGHT ................................................................................................. 16 oz. max. (unit) 1 oz. max. (mating conn.) MOUNTING ............................................................................................ Rigid in any position DO-160 ENV. CAT. ................................................................................ A2D2/A/CJL/EXXXFSX/ABZ/AB/ZA DO-160 ENVIRONMENT
CATEGORY
TEMPERATURE HUMIDITY VIBRATION EXPLOSION WATERPROOFNESS HYDRAULIC FLUID SAND AND DUST FUNGUS RESISTANCE SALT SPRAY MAGNETIC EFFECT POWER INPUT (NORMAL OPERATING CONDITIONS ONLY) VOLTAGE SPIKES AUDIO FREQUENCY CONDUCTED SUSCEPTIBILITY ELECTROMAGNETIC COMPATIBILITY
A2D2 A CJL E X X X F S X
AAC Code Ident. No. 15948
ABZ AB Z A
Drawing Number
Rev.
700-S201-800
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 DC CURRENT LEVEL DETECTOR PART NUMBER S680
INPUT RANGE .................................................... 0 to ± 1000Adc (Continuous) OVERLOAD / TRANSIENT...................... ± 2004A RMS (1 min) ± 1635A RMS (30 min) ± 2960A Peak (5 sec.) TRIP POINT SETTING SET POINT............................................... ±3Adc (±10%) TRIP POINT DELAY (TYPICAL) ............ 350 m-sec. After input (Absolute Value) Exceeds Trip Point ADJUSTMENT RANGE ........................... Field Adjustable ±3 to ±5Adc RESET POINT SETTING RESET POINT……………………………. One Amp (Absolute Value) Below Trip Point RESET POINT DELAY (TYPICAL)……... 10 Sec. After Input (Absolute Value) Decreases Below Reset Point OUTPUT RELAY (Solid State) RELAY CONTACT (SPST) ...................... Contacts Close at and above trip point CONTACT RESISTANCE........................ On 25 Ohms Max, Off 500M Ohms Min. DIELECTRIC STRENGTH ...................... 3.3KV RMS 60Hz CURRENT LIMIT PROTECTION ............ Automatically Limits Contact Current to 370mA OPEN CIRCUIT VOLTAGE……………… 200Vdc OR Peak Max DUTY CYCLE……………………………… Number Of “Change Of State” Operations Is Unlimited. POWER SUPPLY SUPPLY VOLTAGE ................................ +25 to 45Vdc CURRENT DRAIN.................................... 25mA max. TRANSIENT PROTECTION.................... ±60V Peak (30sec.); ±100V Peak (2m sec.)
NOTE: 1. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-005.RFP (XIZ). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB. 5. YELLOW MARKING PAINTED FOR PROTOTYPE IDENTIFICATION.
Code Ident. No. 15948
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE ................... -40°C to +85°C SHOCK & VIBRATION ............................ IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ........................ 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ...................... 3.3Kv RMS 60Hz PRIMARY BAR VOLTAGE ...................... 2Kv RMS max. CASE ........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 6.5 lbs. max.
AAC
Drawing Number
Rev.
700-S680
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT LEVEL DETECTOR PART NUMBER S629-50
INPUT RANGE .................................................... OVERLOAD / TRANSIENT .....................
TRIP POINT SET POINT .............................................. HYSTERESIS ......................................... REPEATABILITY ..................................... OUTPUT RELAY CONTACT (SPST)...................... CONTACT RATING................................. RESPONSE ............................................ DIELECTRIC STRENGTH .....................
POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... PROTECTION .........................................
0 to ± 1000Adc ± 1422A RMS (1 min) ± 1375A RMS (4 min) ± 1161A RMS (30 min) ± 2168A peak (5 sec.) ± 2514A tr (18 M-sec.)
±45Adc Auto reset 5Adc ±5% below trip point ±0.5 Adc
Actuated at and above trip point 10amp @ 45Vdc 50M-sec. MAX. 4000 V RMS coil to contact 1000 V RMS between open contact
+25 to 45Vdc 75mA max. Reverse polarity protected
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE................... -40°C to +85°C SHOCK & VIBRATION ........................... IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ....................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ..................... 3.3Kv RMS 60Hz PRIMARY BAR VOLTAGE ..................... 2Kv RMS max. CASE........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 6.5 lbs. max. NOTE: 1. MOULDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-005.RFP (XIZ). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-S629
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT LEVEL DETECTOR PART NUMBER S623-50
INPUT INPUT CURRENT.................................... OVERLOAD .............................................
TRIP POINT ADJUSTABLE .......................................... HYSTERESIS........................................... OUTPUT RELAY CONTACT (SPST)...................... CONTACT RATING................................. RESPONSE ............................................ DIELECTRIC STRENGTH .....................
POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... REVERSE POLARITY PROTECTION....
NOTE: 1. MOULDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE. TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-006.RFP (XID). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND #8 FLATWASHER. TORQUE MAXIMUM 18 IN-LB.
± 10 to ± 50Adc Auto reset 5 Adc ±5% below trip point
Actuated at above trip point 10amp @ 125Vdc 50M-sec. MAX. 4000 V RMS coil to contact 1000 V RMS between open contact
+25 to 45Vdc 125mA max. 10uA current drain without damage
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +70°C STORAGE TEMPERATURE................... -45°C to +85°C SHOCK & VIBRATION ........................... IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ....................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc PRIMARY BAR VOLTAGE ..................... 2Kv RMS max. DIELECTRIC STRENGTH ..................... 3.3kV RMS 60Hz ISOLATION .............................................. Input/Output/Supply and Case 200 Meg-Ω @ 500Vdc CASE........................................................ Moulded Plastic (GE Lexan) Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 8 lbs. max.
AAC Code Ident. No. 15948
0 to ± 1009Adc continuous ± 2360A Transient (18 m-sec) ± 2014A Peak (5 sec) ± 1268A RMS (1 min) ± 1221A RMS (4 min) ± 1009A RMS (30 min)
Drawing Number
Rev.
700-S623
K
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
TERMINAL IDENTIFICATION
AC CURRENT TRANSDUCER MODEL 1055L 4 TO 20mA 2 WIRE LOOP OPERATION
1. OUTPUT (+) 2. OUTPUT (RTN) PART NO.
INPUT RANGE
1055L-50............... 0 to 50mA 1055L-100............. 0 to 100mA 1055L-200............. 0 to 200mA
PART NO.
INPUT RANGE
1055L-250 ............................... 0 to 250mA 1055L-500 ............................... 0 to 500mA 1055L-1A................................. 0 to 1A
INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................
Aac See Table 50 to 60 Hz 250Aac 100 Times Range For 250m-sec.
OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................
4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) ±0.25% FS (±0.05 mA RMS) 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................
15Vdc Nominal 20mA 7 to 35Vdc
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -20° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) WEIGHT .................................................. 10 oz. Max.
NOTE: MINIMUM DC SUPPLY VOLTAGE = 7V + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. .
Code Ident. No. 15948
TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.
AAC
Drawing Number
Rev.
700-1055L
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC CURRENT TRANSDUCER SERIES S383L 4 TO 20mA 2 WIRE LOOP OPERATION
TERMINAL IDENTIFICATION 1. OUTPUT (+) 2. OUTPUT (RTN)
PART NO.
INPUT RANGE
S383L-50 .............. 0 to 50mA S383L-100 ............ 0 to 100mA S383L-200 ............ 0 to 200mA
PART NO.
INPUT RANGE
S383L-250............................... 0 to 250mA S383L-500............................... 0 to 500mA S383L-1A ................................ 0 to 1A
INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................
Aac See Table 50 to 60 Hz 250Aac 100 Times Range For 250m-sec.
OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................
4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) ±0.25% FS (±0.05 mA RMS) 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................
15Vdc Nominal 20mA 7 to 35Vdc
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -40° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) CASE **.................................................... Aluminum type 1100-0 (finish black semi-gloss enamel) WEIGHT .................................................. 10 oz. Max.
NOTE: MINIMUM DC SUPPLY VOLTAGE = 7V + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. .
Code Ident. No. 15948
TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.
AAC
Drawing Number
Rev.
700-S383L-1003AM2
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC CURRENT TRANSDUCER SERIES 1002M1 MODEL NO.
INPUT CURRENT
1002M1-250mA .... 0 to 0.25 1002M1-500mA .... 0 to 0.50 1002M1-1.............. 0 to 1 1002M1-5.............. 0 to 5 1002M1-10............ 0 to 10 1002M1-20............ 0 to 20
INPUT CURRENT RANGE..................................................... FREQUENCY........................................... FREQUENCY RANGE............................. OVERLOAD ............................................. OUTPUT VOLTAGE SIGNAL.................................. ACCURACY ............................................. RESPONSE (10 to 90%).......................... RIPPLE..................................................... TEMPERATURE COEFFICIENT ............ OUTPUT IMPEDANCE............................ OUTPUT PROTECTION ......................... POWER SUPPLY SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... OVER VOLTAGE PROTECTION............ REVERSE POLARITY PROTECTION....
TERMINAL IDENTIFICATION A. B. C. D. E. F.
Code Ident. No. 15948
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT SIGNAL (RTN) SPARE OUTPUT SIGNAL (+) SPARE
MODEL NO.
INPUT CURRENT
1002M1-25 .............................. 0 to 25 1002M1-50 .............................. 0 to 50 1002M1-65 .............................. 0 to 65 1002M1-100 ............................ 0 to 100 1002M1-150 ............................ 0 to 150 1002M1-200 ............................ 0 to 200 1002M1-250 ............................ 0 to 250
Aac See Table (ADDITIONAL RANGES AVALIABLE) 400 Hz (50 & 60 Hz models available) 375 TO 475 Hz 500Aac Continuously
0 to +5Vdc FS (Full Scale) ±0.5% FS (±25mA) 10 m-sec max. 10mV RMS max. ±0.005% FS /°C max. 1000Ohms ±5% Output terminals E & C will withstand ±32Vdc or short circuit continuously 28Vdc ±4Vdc 100mA max. Terminals A & B withstand ±35Vdc without damage 10uA max. current drain without damage.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -55° to +85°C STORAGE TEMPERATURE RANGE..... -55° to +125°C DIELECTRIC STRENGTH ...................... 350V RMS (all terminals to case) INSULATION RESISTANCE ................... 100 M-Ohms (all terminals to case) ALTITUDE................................................ Operating sea level to 60,000 ft. VIBRATION.............................................. Operating- 0.06 in. D.A., 10 to 55Hz (method 201 of MIL-STD-202) SHOCK..................................................... Operating 50G, 11 m-sec half sine pulse method 213, Condition A of MIL-STD-202 MOISTURE RESISTANCE ..................... Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY ......................... 0% to 95% RH ATTITUDE................................................ Unit will perform as specified when mounted in any position WEIGHT .................................................. 1.25 lbs. Max.
AAC
Drawing Number
Rev.
700-1002M1
N
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC RMS CURRENT SENSOR SERIES S402
PART NO.
INPUT CURRENT RANGE A RMS
PART NO.
S402-250mA ............... 0 TO 250mA S402-500mA ............... 0 TO 500mA S402-1......................... 0 TO 1A S402-2......................... 0 TO 2A S402-5......................... 0 TO 5A S402-10....................... 0 TO 10A
INPUT CURRENT RANGE A RMS
S402-20 ................................... 0 TO 20A S402-50 .................................. 0 TO 50A S402-100 ................................ 0 TO 100A S402-150 ................................ 0 TO 150A S402-200 ................................. 0 TO 200A S402-250 ................................. 0 TO 250A
INPUT RANGE ..................................................................... See Table FREQUENCY RANGE ............................................. 57 to 63Hz (50 & 400Hz model available) OVERLOAD .............................................................. 200A continuously OUTPUT VOLTAGE SIGNAL................................................... ACCURACY.............................................................. RESPONSE (0 to 90%) ............................................ RIPPLE ..................................................................... TEMPERATURE COEFFICIENT ............................. OUTPUT IMPEDANCE ............................................ OUTPUT PROTECTION..........................................
POWER SUPPLY SUPPLY VOLTAGE ................................................. CURRENT DRAIN.................................................... OVER VOLTAGE PROTECTION ............................ REVERSE POLARITY PROTECTION ....................
TERMINAL IDENTIFICATION A. B. C. D. E. F.
Code Ident. No. 15948
SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) OUTPUT (RTN) SPARE OUTPUT (+) SPARE
0 to 5Vdc FS (Full Scale) ±.5% FS (±25mV) 100 m-sec 10mV RMS max. ± .02% FS/°C max. 1000 Ohms ±5% Output terminals E & C will withstand 32Vdc or short circuit continuously
28Vdc ±4Vdc 100mA max. Terminals A & B withstand ±35Vdc without damage 10µA max current drain without damage.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................. -0°C to +70°C STORAGE TEMPERATURE RANGE ..................... -25°C to +85°C DIELECTRIC STRENGTH ....................................... 350V RMS (all terminals to case) INSULATION RESISTANCE.................................... 100M-Ohms (all terminals to case) ALTITUDE................................................................. Operating: sea level to 60,000 ft. VIBRATION............................................................... Operating: 0.06 in. D.A., 10 to 55 Hz (Method 201 of MIL-STD-202) SHOCK ..................................................................... Operating: 50g, 11 m-sec half sine pulse Method 213, Condition A of MIL-STD-202. MOISTURE RESISTANCE ...................................... Will meet Method 106 of MIL-STD-202 and Method 507.1 Proc. 1 of MIL-STD-810. OPERATING HUMIDITY .......................................... 0% to 95% RH ATTITUDE ................................................................ Unit will perform as specified when mounted in any position. WEIGHT ................................................................... 1.25 lbs. max. ADD “-P” TO MODEL NUMBER FOR SPECIAL POTTING. SENSOR IS CAPABLE OF OPERATING WHILE SUBMERGED IN TRANSFORMER OIL.
AAC
Drawing Number
Rev.
700-S402-1004
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC CURRENT TRANSDUCER SERIES C SELF - POWERED PART
INPUT
NUMBER
OVERLOAD CAPABILITY
CURRENT
CONTINUOUS
AMPS AC TRANSIENT SEC/HR
C-1........................................0 to 1A ............................... 10A ...................................... 50A C-2........................................0 to 2A ............................... 15A ...................................... 100A C-5........................................0 to 5A ............................... 15A ...................................... 250A C-10......................................0 to 10A ............................. 20A ...................................... 500A C-20......................................0 to 20A ............................. 30A ...................................... 500A INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ LINEAR OVER RANGE............................................................. OVER LOAD CAPABILITY........................................................ DIELECTRIC.............................................................................. BURDEN....................................................................................
Aac See Table 47 to 1000Hz 20% of Range Aac See Table 2KV RMS, 60Hz, 1 min. 0.5VA max.
OUTPUT CURRENT SIGNAL................................................................... ACCURACY * (60Hz)................................................................. (47 to 1000Hz).................................................... RIPPLE ...................................................................................... RESPONSE (0 to 99%) ............................................................. LOAD RESISTANCE RANGE................................................... CALIBRATION ADJUSTMENT ................................................. STABILITY PER YEAR..............................................................
0 to 1mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 0 to 11K-Ohms ±10% FS ±0.1% FS max.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................. STORAGE TEMPERATURE .................................................... ISOLATION................................................................................ INSULATION RESISTANCE..................................................... SURGE CAPABILITY ................................................................ WEIGHT ...................................................................................
-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.
* INCLUDES COMBINED WORSE CASE EFFECTS OF TEMPERATURE AND LOAD CHANGES. TERMINAL IDENTIFICATION 1. 2. 3. 4.
OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT
NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.
Code Ident. No. 15948
ADD “-E” AND OR “-F” TO PART NUMBER FOR SPECIAL OPTIONS
“-E” OUTPUT VOLTAGE OPTION ADD -E PLUS DESIRED OUTPUT VOLTAGE FROM 0 TO A MAX OF 10
“-F” CALIBRATION FREQ. OPTION ADD -F PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000
AAC
Drawing Number
Rev.
700-C
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC VOLTAGE TRANSDUCER SERIES CX 4 TO 20mA LOOP - POWERED
PART NUMBER
INPUT CURRENT
OVERLOAD CAPABILITY
AMPS AC
CONTINUOUS
TRANSIENT SEC/HR
CX-1....................................... 0 to 1A.................................. 10A............................................... 50A CX-2....................................... 0 to 2A.................................. 15A............................................... 100A CX-5....................................... 0 to 5A.................................. 15A............................................... 250A CX-10..................................... 0 to 10A................................ 20A............................................... 500A CX-20..................................... 0 to 20A................................ 30A............................................... 500A INPUT RANGE...................................................................................... FREQUENCY............................................................................ LINEAR OVER RANGE ............................................................ OVER LOAD CAPABILITY ....................................................... DIELECTRIC............................................................................. BURDEN ................................................................................... OUTPUT CURRENT SIGNAL .................................................................. ACCURACY * (60Hz)................................................................ (47 to 1000Hz .................................................... RIPPLE...................................................................................... RESPONSE (0 to 99%)............................................................. LOAD RESISTANCE ................................................................ LOAD RESISTANCE RANGE ..................................................
TERMINAL IDENTIFICATION 1. 2. 3. 4.
OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT
Aac See Table 47 to 1000Hz 20% of Range Aac See Table 2KV RMS, 60Hz, 1 min. 0.5VA max.
PROTECTION .......................................................................... CALIBRATION ADJUSTMENT ................................................ STABILITY PER YEAR .............................................................
4 to 20mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 250 Ohms Nominal 0 to 250 Ohms @ 15Vdc 0 to 1100 Ohms @ 32Vdc Reverse Polarity Protected ±10% of FS ±0.1% FS max.
POWER SUPPLY SUPPLY VOLTAGE .................................................................. CURRENT DRAIN .................................................................... SUPPLY VOLTAGE RANGE....................................................
+15Vdc Nominal 20mA 10 to 35Vdc
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ................................................ STORAGE TEMPERATURE.................................................... ISOLATION ............................................................................... INSULATION RESISTANCE .................................................... SURGE CAPABILITY................................................................ WEIGHT ...................................................................................
-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.
* INCLUDES COMBINED WORSE CASE EFFECTS OF TEMPERATURE, SUPPLY VOLTAGE AND LOAD CHANGES. NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.
Code Ident. No. 15948
ADD “-F” TO PART NUMBER PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000Hz FOR CALIBRATION FREQ. OPTION.
AAC
Drawing Number
Rev.
700-CX
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
A.C.CURRENT SENSOR SERIES 1003AM1 OUTPUT INPUT CURRENT IMPEDANCE MODEL NO. 1003AM1-2...............................0 to 2Aac ...........................................................25 1003AM1-5...............................0 to 5Aac ...........................................................10 1003AM1-10.............................0 to 10Aac ........................................................5.0 1003AM1-15.............................0 to 15Aac ........................................................4.0 1003AM1-20.............................0 to 20Aac ........................................................2.5 1003AM1-25.............................0 to 25Aac ........................................................2.2 1003AM1-30.............................0 to 30Aac ........................................................2.0 1003AM1-50.............................0 to 50Aac ........................................................1.0 1003AM1-60.............................0 to 60Aac ........................................................0.8 1003AM1-75.............................0 to 75Aac ......................................................0.75 1003AM1-100...........................0 to 100Aac ......................................................0.5 INPUT CURRENT RANGE................................................................................ FREQUENCY ......................................................................................... FREQUENCY RANGE ........................................................................... OVERLOAD............................................................................................
See Table 60Hz 57 to 63Hz 250Aac Continuous
OUTPUT VOLTAGE SIGNAL ................................................................................ 0 to 5Vdc FS (Full Scale) ACCURACY............................................................................................ ± 1% FS for 10A range and above ±2% FS for 2A & 5A ranges RIPPLE ................................................................................................... 3% FS RMS max. RESPONSE............................................................................................ 150 m-sec max. REPEATABILITY.................................................................................... ± 0.5% FS TEMPERATURE COEFFICIENT........................................................... ± 0.04% FS/ °C max. for 10A ranges & above ±0.08% FS/°C for 2A & 5A ranges OUTPUT IMPEDANCE .......................................................................... K-Ohms See Table OUTPUT SIGNAL @ OVERLOAD ....................................................... 11Vdc max. POWER SUPPLY SUPPLY VOLTAGE ............................................................................... None, self excited ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ............................................... STORAGE TEMPERATURE RANGE ................................................... ISOLATION ............................................................................................ INSULATION RESISTANCE ................................................................. WEIGHT .................................................................................................
- 20° C to 70°C - 55°C to 85°C Input/Output/Case 100 M-Ohms output to case 5 oz. max.
TERMINAL IDENTIFICATION RED LEAD: OUTPUT (+) BLACK LEAD: OUTPUT (RTN)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-1003AM1
K
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 A.C. CURRENT SENSOR SERIES 1004 INPUT PART NO.
CURRENT
OUTPUT
INPUT
IMPEDANCE
PART NO.
1004-2.......................0 TO 2 ................
25
1004-150............ 0 TO 150 ....................
0.9
10
1004-200............ 0 TO 200 ....................
0.6
1004-10.................. 0 TO 10 ................
5.0
1004-250............ 0 TO 250 ....................
0.5
1004-20...................0 TO 20 ................
2.5
1004-300............ 0 TO 300 ....................
0.5
1004-50...................0 TO 50 ................
1.0
1004-350............ 0 TO 350 ....................
0.4
1004-100...............0 TO 100 ................
0.5
1004-400............ 0 TO 400 ....................
0.3
INPUT CURRENT RANGE ...................................................................................... FREQUENCY ............................................................................ FREQUENCY RANGE .............................................................. OVERLOAD...............................................................................
Aac See Table 400Hz 375 to 475Hz 500Aac continuously
OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... RESPONSE............................................................................... RIPPLE ...................................................................................... TEMPERATURE COEFFICIENT.............................................. OUTPUT IMPEDANCE ............................................................. REPEATABILITY....................................................................... OUTPUT SIGNAL @ OVERLOAD ...........................................
0 to +5Vdc FS (Full Scale) ± 0.5% FS (±25mV) 150 m-sec max. 0.4% FS RMS ±0.04% FS/°C max. K-Ohms max. See Table ±0.1% FS 11Vdc typical
POWER SUPPLY (PS) SUPPLY VOLTAGE .................................................................
Non, Self Excited
DIELECTRIC STRENGTH........................................................ ALTITUDE ................................................................................. VIBRATION ............................................................................... SHOCK ...................................................................................... MOISTURE RESISTANCE .......................................................
Code Ident. No. 15948
OUTPUT IMPEDANCE
1004-5...................... 0 TO 5 ................
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... INSULATION RESISTANCE ....................................................
TERMINAL IDENTIFICATION A. SPARE B. SPARE C. OUTPUT (RTN) D. SPARE E. OUTPUT (+) F. CASE GROUND
CURRENT
OPERATING HUMIDITY........................................................... ATTITUDE ................................................................................. WEIGHT ....................................................................................
AAC
-55° to +85°C -60° to +100°C 100M-Ohms (Terminals A thru E to case & terminal F) 350V RMS (Terminals A thru E to case & terminal F) Operating sea level to 60,000 ft. Operating - 0.06 in D.A., 10 to 55Hz method 201 of MIL-STD-202 Operating 50g, 11m-sec half sine pulse method 213 Condition A of MIL-STD-202 Will meet method 106 of MIL-STD-202 and method 507.1 proc. 1 of MIL-STD-810 0% to 95% RH Unit will perform as specified when mounted in any position 1.25 lbs. Max.
Drawing Number
Rev.
700-1004
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 A.C. CURRENT SENSOR
°
SERIES 1005
CURRENT RANGE PART NO.
AMPS AC
OUTPUT
CURRENT
IMPEDANCE K OHMS
PART NO.
AMPS AC
K OHMS
25
1005-50..........................50 ....................
1.5
1005-5................................5 ................
10
1005-75..........................75 ....................
1.0
1005-10............................10 ................
7.0
1005-100......................100 ....................
0.7
1005-15............................15 ................
5.0
1005-150......................150 ....................
0.5
1005-20............................20 ................
3.5
1005-200......................200 ....................
0.4
1005-25............................25 ................
3.0
1005-250......................250 ....................
0.3
1005-30............................30 ................
2.5
1005-300......................300 ....................
0.25
1005-40............................40 ................
1.75
OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY...............................................................................
See Table 50 to 60Hz 200A (2 to 100A ranges) 400A (150 to 300A ranges)
REPEATABILITY....................................................................... VOLTAGE SIGNAL @ OVERLOAD ......................................... VOLTAGE SIGNAL LINEAR TO...............................................
0 to 5Vdc FS (Full Scale) ± 1% FS for 10A range and above ±2% FS for 2A and 5A ranges 100mV RMS typical 80m-sec typical See Table ±0.04% FS/°C max. ±0.08% FS/°C max. (2 & 5A units) ±0.1% FS 11Vdc max. 6Vdc (120% FS)
POWER SUPPLY (PS) SUPPLY VOLTAGE .................................................................
Non, Self Excited
RIPPLE ...................................................................................... RESPONSE (10 to 90%) ........................................................... IMPEDANCE ............................................................................. TEMPERATURE COEFFICIENT..............................................
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... ISOLATION ............................................................................... CONDUCTOR CABLE VOLTAGE............................................ CASE ........................................................................................ WEIGHT ...................................................................................
5-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG AND WIRE LUGS UP TO 9/32” WIDE.
AAC Code Ident. No. 15948
IMPEDANCE
1005-2................................2 ................
INPUT CURRENT RANGE ...................................................................................... OPERATING FREQUENCY ..................................................... OVERLOAD CONTINUOUS.....................................................
TERMINALS:
OUTPUT
RANGE
-20° to +70°C -55° to +85°C Input/Output/Case 1.5KV max. (5KV with Insul. Cable) Molded Plastic Meets UL Flammability Rating 94V- 0 5 oz. max.
Drawing Number
Rev.
700-1005
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
TERMINAL IDENTIFICATION
AC CURRENT TRANSDUCER MODEL 1055 4 TO 20mA 2 WIRE LOOP OPERATION
1. OUTPUT (+) 2. OUTPUT (RTN) PART NO.
INPUT RANGE
1055-2 .................. 0 to 2Aac 1055-5 .................. 0 to 5Aac 1055-10 ................ 0 to 10Aac 1055-15 ................ 0 to 15Aac 1055-20 ................ 0 to 20Aac 1055-25 ................ 0 to 25Aac 1055-30 ................ 0 to 30Aac
PART NO.
INPUT RANGE
1055-40 .................................. 0 to 40Aac 1055-50 .................................. 0 to 50Aac 1055-75 .................................. 0 to 75Aac 1055-100 ................................ 0 to 100Aac 1055-150 ................................ 0 to 150Aac 1055-200 ................................ 0 to 200Aac 1055-250 ................................ 0 to 250Aac
INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................
Aac See Table 50 to 60 Hz 500Aac 10 Times Range For 250m-sec.
OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................
4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) 10mV RMS max. 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................
15Vdc Nominal 20mA 5 to 35Vdc
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -20° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) WEIGHT .................................................. 10 oz. Max.
NOTE: MINIMUM DC SUPPLY VOLTAGE = VX + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. Vx = 7V FOR P/N S383-2 AND S383-5 VX = 5V FOR P/N S383-10 THRU S383-250
Code Ident. No. 15948
TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.
AAC
Drawing Number
Rev.
700-1055
F
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC CURRENT TRANSDUCER SERIES S383 4 TO 20mA 2 WIRE LOOP OPERATION
TERMINAL IDENTIFICATION 1. OUTPUT (+) 2. OUTPUT (RTN)
PART NO.
INPUT RANGE
S383-2A................ 0 to 2Aac S383-3A................ 0 to 3Aac S383-5A................ 0 to 5Aac S383-10A.............. 0 to 10Aac S383-15A.............. 0 to 15Aac S383-20A.............. 0 to 20Aac S383-25A.............. 0 to 25Aac S383-30A.............. 0 to 30Aac
PART NO.
INPUT RANGE
S383-40A ................................ 0 to 40Aac S383-50A ................................ 0 to 50Aac S383-75A ................................ 0 to 75Aac S383-100A .............................. 0 to 100Aac S383-150A .............................. 0 to 150Aac S383-200A .............................. 0 to 200Aac S383-250A .............................. 0 to 250Aac
INPUT RANGE..................................................... FREQUENCY........................................... OVERLOAD CONTINUOUS ................... OVERLOAD TRANSIENT .......................
Aac See Table 50 to 60 Hz 500Aac 10 Times Range For 250m-sec.
OUTPUT CURRENT SIGNAL ................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%).......................... LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. CURRENT SIGNAL @ OVERLOAD ....... PROTECTION .........................................
4 to 20mAdc FS (Full Scale) ±0.5% FS or ±0.1mA max. (Over Temperature Range) 10mV RMS max. 100mS max. 250 Ohms Nominal 0 to 1400 Ohms (See Note) 30mA TYP. Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE ................................ CURRENT DRAIN ................................... SUPPLY VOLTAGE RANGE...................
15Vdc Nominal 20mA 5 to 35Vdc
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -40° to +85°C STORAGE TEMPERATURE RANGE..... -40° to +85°C ISOLATION .............................................. Input/Output/Case INSULATION RESISTANCE ................... 200 M-Ohms @ 500Vdc INPUT CONDUCTOR VOLTAGE ........... 1.5KV max. (5KV max. with insulated cable) CASE **.................................................... Aluminum type 1100-0 (finish black semi-gloss enamel) WEIGHT .................................................. 10 oz. Max.
NOTE: MINIMUM DC SUPPLY VOLTAGE = VX + .02 (RL) RL = ANY VALUE BETWEEN 0 AND 1400 OHMS. Vx = 7V FOR P/N S383-2 AND S383-5 VX = 5V FOR P/N S383-10 THRU S383-250
Code Ident. No. 15948
TERMINAL SCREWS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32 WIDE.
AAC
Drawing Number
Rev.
700-S383-1003AM2
K
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC RMS CURRENT TRANSDUCER SERIES 1070 4 to 20mA 2 WIRE LOOP POWER PART CURRENT NUMBER RANGE 1070-2.......................... 0 to 2 1070-5 .......................... 0 to 5 1070-10........................ 0 to 10 1070-15………………. 0 to 15 1070-20 ........................ 0 to 20 1070-25 ........................ 0 to 25 1070-30 ........................ 0 to 30
PART CURRENT NUMBER RANGE 1070-40………………… 0 to 40 1070-50………………… 0 to 50 1070-75………………… 0 to 75 1070-100……………….. 0 to 100 1070-150 ………………. 0 to 150 1070-200……………….. 0 to 200 1070-250………………. 0 to 250
INPUT RANGE ........................................................................... OVERLOAD ................................................................... FREQUENCY RANGE....................................................
Aac rms (see table) 500Aac 20 to 2KHz
OUTPUT CURRENT SIGNAL ........................................................ ACCURACY (Over the Temperature Range).................. RIPPLE ........................................................................... RESPONSE (10 to 90%)................................................. LOAD RESISTANCE (RL) .............................................. LOAD RESISTANCE RANGE ........................................ CURRENT SIGNAL @ OVERLOAD............................... OUTPUT PROTECTION.................................................
4 to 20mAdc FS ±0.25% FS max. (± 50uA) note 1 .2% max. (40uAac) 300m-sec. 250 Ohms Nominal 0 to 300 Ohms 23mAdc typ. Reverse Polarity Protection
POWER SUPPLY SUPPLY VOLTAGE ....................................................... CURRENT DRAIN .......................................................... SUPPLY VOLTAGE RANGE ..........................................
+15Vdc 4 to 23mAdc +12 TO 32Vdc
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -40° to +85°C STORAGE TEMPERATURE RANGE............................. -55° to +125°C HUMIDITY (Operating).................................................... 0% to 95%RH MOISTURE RESISTANCE ............................................. MIL-STD-202 Method 106 (note 2) 2 RANDOM VIBRATION (Operating)................................. MIL-STD-810F, Proc.1,Cat.12, WO=.095G /Hz, Time1 hr, Fig. 514.5C-8 Overall level 12.G- RMS SHOCK ........................................................................... 50g 11m-sec. half sine pulse ISOLATION ..................................................................... Input to output 5KV rms 60Hz/1min. INSULATION RESISTANCE........................................... 500 M-Ohms @ 500Vdc CASE MATERIAL ........................................................... Molded Plastic meets UL flammability rating 94V-O (color light gray) WEIGHT ......................................................................... 6 oz. Max. NOTE 1: Specified accuracy includes the combined worst case effects of Zero Offset, Temperature, Hysteresis, Supply Swings and Current Cable Positioning. NOTE 2: Meets Specified Moisture requirements with option C & D only. TERMINAL IDENTIFICATION 1. SUPPLY (+) 2. SUPPLY (RTN) 3-9. SPARE
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-1070
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT TRANSDUCER SPLIT CORE RMS RESPONDING MAXIMUM
MODEL ACTS-20-05
RANGE 2A 5A
CONTINUOUS 80A 100A
ACTS-20-50
10A 20A 50A
80A 110A 175A
125A 150A 215A
250A 300A 400A
ACTS-20-200
100A 150A 200A
200A 300A 400A
300A 450A 500A
600A 800A 1000A
SPECIFICATIONS Output Signal Output Limit Accuracy Response Time Frequency Range Power Supply Isolation Voltage Input Ranges Sensing Aperture Case Environmental Listing
6 SEC. 125A 125A
1 SEC. 250A 250A
4-20mA, Loop-powered._True RMS__________________________ 23mA ______________________________________ .08% FS________ __________________ 600mS (to 90% step change) 10-400Hz 24VDC Nominal, 40VDC Maximum__________________________ UL listed to 1270VAC, tested to 5KV Field selectable ranges from 0-200A. Consult factory for custom ranges.______ __________________ 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -4 to 122° F (-20 to 50° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada), CE
ACTS-
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-ACTS
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT TRANSDUCER SPLIT CORE AVERAGE RESPONDING MAXIMUM
TYPE -05 (ACT-20 only)
RANGE 2A 5A
CONTINUOUS 80A 100A
-50
10A 20A 50A
80A 110A 175A
125A 150A 215A
250A 300A 400A
-200
100A 150A 200A
200A 300A 400A
300A 450A 500A
600A 800A 1000A
MODEL Output Signal Output Limit Accuracy Response Time Frequency Range Other Frequencies Power Supply Loading Isolation Voltage Input Range Sensing Aperture Case Environmental Listing
1 SEC. 200A 250A
ACT-05-(type) ACT-10-(type) ACT-20-(type) 0-5VDC 0-10VDC 4-20mA 10VDC 15VDC 40mA 1.0% FS 1.0% FS 0.5% FS 100mS 100mS 300mS 50-60Hz 50-60Hz 20-100Hz Special calibration available for any frequency from 10-400Hz Self-Powered Self-Powered 12-40VDC Loop-powered 1MΩ minimum for rated accuracy 100mΩ add 1.3% error. UL listed to 1270VAC, tested to 5KV Field selectable ranges from 0-200A. Custom ranges available, consult factory. 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -4 to 122° F (-20 to 50° C), 0-95% RH non-condensing UL 508 Industrial Control Equipment (USA & Canada), CE
AAC Code Ident. No. 15948
6 SEC. 100A 124A
Drawing Number
Rev.
700-ACT
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 A.C. CURRENT SENSOR SERIES 1006 OUTPUT MODEL NO. INPUT CURRENT IMPEDANCE
OUTPUT MODEL NO. INPUT CURRENT IMPEDANCE
1006-5.......................0 TO 5 ................
9
1006-200............ 0 TO 200 ....................
.22
1006-10...................0 TO 10 ................
4.5
1006-250............ 0 TO 250 ....................
.18
1006-20...................0 TO 20 ................
2.2
1006-300........... 0 TO 300 ....................
.22
1006-25...................0 TO 25 ................
1.7
1006-350............ 0 TO 350 ....................
.2
1006-35...................0 TO 35 ................
1.4
1006-400............ 0 TO 400 ....................
.17
1006-50...................0 TO 50 ................
.88
1006-500............ 0 TO 500 ....................
.13
1006-75...................0 TO 75 ................
.61
1006-600............ 0 TO 600 ....................
.11
1006-100...............0 TO 100 ................
.45
1006-800............ 0 TO 800 ....................
.12
1006-150...............0 TO 150 ................
.30
1006-1000........ 0 TO 1000 ....................
.10
INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ OVERLOAD CONTINUOUS.....................................................
Aac See Table 50 & 60Hz 500Aac or two X FS which ever is greater
OUTPUT VOLTAGE SIGNAL ................................................................... ACCURACY............................................................................... RIPPLE (RMS)........................................................................... RESPONSE (10 to 90%) ........................................................... IMPEDANCE ............................................................................. TEMPERATURE COEFFICIENT.............................................. REPEATABILITY....................................................................... VOLTAGE SIGNAL @ OVERLOAD ......................................... VOLTAGE SIGNAL LINEAR TO...............................................
0 to 5Vdc FS (Full Scale) * ± 0.5% FS 10mV RMS typical 130m-sec typical K Ohms max. See Table ±0.02% FS/°C max. ±0.1% FS 10Vdc max. 6Vdc (120% FS)
POWER SUPPLY (PS) SUPPLY VOLTAGE .................................................................
None, Self Excited
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. STORAGE TEMPERATURE RANGE ...................................... ISOLATION ............................................................................... CONDUCTOR CABLE VOLTAGE............................................ CASE ........................................................................................ WEIGHT ................................................................................... TERMINALS:
-20° to +70°C -55° to +85°C Input/Output/Case 1.5KV max. (5KV with Insul. Cable) Molded Plastic Meets UL Flammability Rating 94V- 0 1.2 lbs. max.
* 4 to 20mA Two Wire Output Option Available
5-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG AND WIRE LUGS UP TO 9/32” WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-1006
H
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT TRANSDUCER SERIES 1006X 4 TO 20 mA 2 WIRE OPERATION
PART NO.
INPUT CURRENT
1006X-5 ................ 5 1006X-10 .............. 10 1006X-20 .............. 20 1006X-25 .............. 25 1006X-50 .............. 50 1006X-75 .............. 75 1006X-100 ............100 1006X-150 ............150
PART NO.
INPUT CURRENT
1006X-200 ............................... 200 1006X-250 ............................... 500 1006X-300 ............................... 300 1006X-400 ............................... 400 1006X-500 ............................... 500 1006X-600 ............................... 600 1006X-800 ............................... 800 1006X-1000 .............................1000 1006X-1200 .............................1200
INPUT CURRENT RANGE..................................................... See Table FREQUENCY ........................................... 50 & 60 Hz OVERLOAD CONTINUOUS.................... 500Aac or two X FS which ever is greater to a maximum of 1750A OUTPUT VOLTAGE SIGNAL.................................. ACCURACY ............................................. RIPPLE..................................................... RESPONSE (10 to 90%) .......................... TEMPERATURE COEFFICIENT............. LOAD RESISTANCE (RL) ....................... LOAD RESISTANCE RANGE ................. REPEATABILITY ..................................... CURRENT SIGNAL @ OVERLOAD ....... PROTECTION ..........................................
4 to 20mAdc FS (Full Scale) ±0.5% FS (±0.1mA) Over Temperature Range .2% FS Typical 100 m-sec max. ± 0.02% FS/°C max. 250 Ohms Nominal 0 to 1400 Ohms (See Table II) ±0.1% FS 30mA Typical Reverse Polarity Protected
POWER SUPPLY SUPPLY VOLTAGE (PS) ........................ 15Vdc Nominal CURRENT DRAIN.................................... 20mA SUPPLY VOLTAGE RANGE................... 5 to 35Vdc (See Table II) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE . -20° to +70°C STORAGE TEMPERATURE RANGE..... -55° to +85°C ISOLATION ............................................. Input/Output/Case CONDUCTOR CABLE VOLTAGE.......... 1.5KV max. (5KV with Insul. Cable) CASE ........................................................ Molded Plastic meets UL flammability rating 94V-0 WEIGHT .................................................. 1.2 lbs. max.
TERMINALS: 5-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG. AND WIRE LUGS UP TO 9/32” WIDE.
RL = VX + (.02)RL VX = 5V RL = 5V + (.02)(1400) = 33Vdc Code Ident. No. 15948
TABLE II SUPPLY (PS) VS LOAD LOAD RESISTANCE (RL) SUPPLY LOAD RESISTANCE 10Vdc..................................... 0 to 250 Ohms 15Vdc..................................... 0 to 500 Ohms 20Vdc..................................... 0 to 750 Ohms 25Vdc..................................... 0 to 1000 Ohms 27Vdc..................................... 0 to 1100 Ohms 33Vdc..................................... 0 to 1400 Ohms
AAC
Drawing Number
Rev.
700700- 1006X
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC RMS CURRENT TRANSDUCER SERIES S714 PART CURRENT PART CURRENT NUMBER RANGE NUMBER RANGE S714-5 ................................. 0 to 5 S714-150............................. 0 to 150 S714-10 ............................... 0 to 10 S714-200............................. 0 to 200 S714-20 ............................... 0 to 20 S714-250............................. 0 to 250 S714-25 ............................... 0 to 25 S714-300............................. 0 to 300 S714-50 ............................... 0 to 50 S714-400............................. 0 to 400 S714-75 ............................... 0 to 75 S714-500............................. 0 to 500 S714-100 ............................. 0 to 100 S714-600............................. 0 to 600
TERMINAL IDENTIFICATION 12345-
Code Ident. No. 15948
A. B. C. D. E. F.
SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT SIGNAL (+) OUTPUT (RTN) CASE GROUND SPARE
INPUT RANGE CURRENT RANGE........................................................... See Table Aac FS (Full Scale) CURRENT OVERLOAD CONTINUOUS ......................... 500Aac or two X FS which is greater FREQUENCY RANGE...................................................... 360 TO 440 Hz (60Hz Models available) OUTPUT VOLTAGE SIGNAL........................................................... 0 to +5Vdc FS ACCURACY ..................................................................... ±0.5% FS LINEARITY........................................................................ ±0.20% FS RESPONSE TIME (10 TO 90%)....................................... 75 ms max. CREST FACTOR .............................................................. 0 to 5 OUTPUT IMPEDANCE..................................................... 10 Ohms max. OUTPUT RIPPLE ............................................................. 5mV RMS max. OUTPUT LOAD ................................................................ 10K Ohms min. SHORT CIRCUIT.............................................................. Protected TEMPERATURE COEFFICIENT ..................................... ±0.01% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... +14 TO +32Vdc TRANSIENT PROTECTION ............................................ ±60V (t<100ms) CURRENT DRAIN ............................................................ 10mA max. REVERSE POLARITY PROTECTION............................. 100µA max current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -40° to +85°C STORAGE TEMPERATURE............................................ -55° to +85°C OPERATING HUMIDITY .................................................. 0% to 95% RH MOISTURE RESISTANCE............................................... Will meet Method 106 of MIL-STD-202 & Method 507.1, Proc. 1 of MIL-STD-810 ALTITUDE......................................................................... Operating: Sea level to 70,000 ft. RANDOM VIBRATION...................................................... Operating MIL-STD-810E Category 5, Proc. 1, 2 WO=0.012G Hz, Duration 1 hr., Figure 514.4-8 Suggested Vibration levels for high performance Aircraft 12.5 G-RMS composite DIELECTRIC STRENGTH ............................................... 350V RMS terminals 1-4 to 5 & case INSULATION RESISTANCE ............................................ 100 M-Ohms min. ATTITUDE......................................................................... Unit will perform as specified when mounted in any position. SHOCK.............................................................................. Operating: 50g, 11 m-sec half sine pulse Method 213 Condition A of MIL-STD-202. WEIGHT............................................................................ 1.5 lbs. max. MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.
AAC
Drawing Number
Rev.
700-S714-1006
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC RMS CURRENT TRANSDUCER SERIES S786 PART CURRENT NUMBER RANGE S786-5 ................................. 0 to 5 S786-10 ............................... 0 to 10 S786-20 ............................... 0 to 20 S786-25 ............................... 0 to 25 S786-50 ............................... 0 to 50 S786-75 ............................... 0 to 75 S786-100 ............................. 0 to 100 S786-150 ............................. 0 to 150
PART CURRENT NUMBER RANGE S786-200............................. 0 to 200 S786-250............................. 0 to 250 S786-300............................. 0 to 300 S786-400............................. 0 to 400 S786-500............................. 0 to 500 S786-600............................. 0 to 600 S786-800............................. 0 to 800 S786-1000........................... 0 to 1000
INPUT RANGE CURRENT RANGE........................................................... See Table Aac FS (Full Scale) CURRENT OVERLOAD CONTINUOUS ......................... 500Aac or two X FS which is greater FREQUENCY RANGE...................................................... 60 Hz (400Hz Models available) OUTPUT VOLTAGE SIGNAL........................................................... 0 to +5Vdc FS ACCURACY ..................................................................... ±0.5% FS LINEARITY........................................................................ ±0.20% FS RESPONSE TIME (10 TO 90%)....................................... 130 ms typ. CREST FACTOR .............................................................. 0 to 5 OUTPUT IMPEDANCE..................................................... 10 Ohms max. OUTPUT RIPPLE ............................................................. 10mV RMS typ. OUTPUT LOAD ................................................................ 10K Ohms min. SHORT CIRCUIT.............................................................. Protected TEMPERATURE COEFFICIENT ..................................... ±0.01% FS/°C max. POWER SUPPLY SUPPLY VOLTAGE ......................................................... +14 TO +32Vdc TRANSIENT PROTECTION ............................................ ±60V (t<100ms) CURRENT DRAIN ............................................................ 10mA max. REVERSE POLARITY PROTECTION............................. 100µA max current drain without damage
TERMINAL IDENTIFICATION 12345-
SUPPLY VOLTAGE (+) SUPPLY (RTN) OUTPUT SIGNAL (+) OUTPUT (RTN) SPARE
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -40° to +85°C STORAGE TEMPERATURE............................................ -45° to +85°C OPERATING HUMIDITY .................................................. 0% to 95% RH DIELECTRIC STRENGTH ............................................... 1500V RMS terminals 1-5 to case INSULATION RESISTANCE ............................................ 200 M-Ohms min. CONDUCTOR CABLE VOLTAGE ................................... 1.5KV max. (5KV with insulated cable) ATTITUDE......................................................................... Unit will perform as specified when mounted in any position. CASE………………………………………………………… Molded Plastic meets UL Flammability 94V-0 WEIGHT…………………………………………………….. 1.2lbs. max. MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS, 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES TO 14 AWG AND WIRE LUGS UP TO 9/32 IN. WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S786-1006
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC RMS CURRENT TRANSDUCER SERIES 1001 REMOVABLE YOKE TYPE
PART NO.
INPUT CURRENT AMPS RMS
1001-100 ..................... 0 TO 100 1001-150 ..................... 0 TO 150 1001-250 ..................... 0 TO 250 1001-500 ..................... 0 TO 500 1001-750 ..................... 0 TO 750
PART NO.
1001-1000................................ 0 TO 1000 1001-1500............................... 0 TO 1500 1001-2000............................... 0 TO 2000 1001-2500............................... 0 TO 2500 1001-3000............................... 0 TO 3000
INPUT RANGE ............................................................................. FREQUENCY ................................................................... CREST FACTORS ........................................................... OVERLOAD ...................................................................... OUTPUT VOLTAGE SIGNAL........................................................... ACCURACY...................................................................... RESPONSE (0 TO 90%) .................................................. RIPPLE ............................................................................. TEMPERATURE COEFFICENT ...................................... OUTPUT IMPEDANCE .................................................... OUTPUT PROTECTION..................................................
POWER SUPPLY SUPPLY VOLTAGE ......................................................... CURRENT DRAIN............................................................ OVER VOLTAGE PROTECTION .................................... REVERSE POLARITY PROTECTION ............................
TERMINAL IDENTIFICATION CONNECTOR A B C D E F
OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE
BARRIER 1 2 3 4
See Table DC to 480Hz Up to 7 2x Range continuously, 10x for 10 sec.
0 to 5Vdc FS (Full Scale) ±1% FS (±50mV) 100 m-sec 25mV RMS @ 60Hz ±.05% FS/°C max. 1000 Ohms ±5% Output terminals 1 & 2 will withstand ±32Vdc or short circuit continuously
+28Vdc ±4Vdc 100mA max. ±35Vdc without damage 10µA max. current drain without damage
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -25°C to +71°C STORAGE TEMPERATURE RANGE ............................. -55°C to +100°C DIELECTRIC STRENGTH ............................................... 350V RMS (all terminals to case) INSULATION RESISTANCE............................................ 100 M-ohms (all terminals to case) ALTITUDE......................................................................... Operating sea level to 60,000 ft. VIBRATION....................................................................... Operating - 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK ............................................................................. Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE .............................................. Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY .................................................. 0% to 95% RH ATTITUDE ........................................................................ Units will perform as specified when mounted in any position WEIGHT ........................................................................... 2 lbs. max.
NOTE: MOLDED TERMINAL BARRIER WITH 5-40 TERMINAL SCREWS AND .375 CENTER DISTANCES. TERMINALS ACCEPT WIRE SIZES UP TO #16 AWG. WITH LUGS TO .281 IN. WIDE. ADD –C TO PART NUMBER FOR CONNECTOR OPTION CONNECTOR TYPE MS3112E-10-6P OR EQUIV.
Code Ident. No. 15948
INPUT CURRENT AMPS RMS
AAC
Drawing Number
Rev.
700-1001
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC RMS CURRENT TRANSDUCER SERIES S461 REMOVABLE YOKE TYPE
PART NO.
INPUT CURRENT AMPS RMS
S461-100 .....................0 TO 100 S461-150 .....................0 TO 150 S461-250 .....................0 TO 250 S461-500 .....................0 TO 500 S461-750 .....................0 TO 750
PART NO.
INPUT CURRENT AMPS RMS
S461-1000 ............................... 0 TO 1000 S461-1500 ............................... 0 TO 1500 S461-2000 ............................... 0 TO 2000 S461-2500 ............................... 0 TO 2500 S461-3000 ............................... 0 TO 3000
INPUT RANGE .............................................................................. See Table FREQUENCY .................................................................... DC to 480Hz CREST FACTORS............................................................ Up to 7 OVERLOAD....................................................................... 2X range continuously, 10X for 10 sec. OUTPUT VOLTAGE SIGNAL ........................................................... 0 to 5Vdc (Full Scale) ACCURACY....................................................................... ±1% FS (±50mV) RESPONSE (0 to 90%) ..................................................... 100 m-sec RIPPLE .............................................................................. 25mV RMS @ 60Hz TEMPERATURE COEFFICIENT...................................... ± .05% FS/°C max. OUTPUT IMPEDANCE ..................................................... 1000 Ohms ±5% OUTPUT PROTECTION ..................................................Output terminals 1 & 2 will withstand ±32Vdc or short circuit continuously POWER SUPPLY SUPPLY VOLTAGE ......................................................... +28Vdc ±4Vdc CURRENT DRAIN............................................................. 100mA max. OVER VOLTAGE PROTECTION..................................... ±35Vdc without damage REVERSE POLARITY PROTECTION ............................. 10µA max current drain without damage.
TERMINAL IDENTIFICATION BARRIER 1 2 3 4 5
OUTPUT (+) OUTPUT (RTN) SUPPLY VOLTAGE (+) SUPPLY VOLTAGE (RTN) SPARE SPARE
CONNECTOR A B C D E F
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -25°C to +71°C STORAGE TEMPERATURE RANGE .............................. -55°C to +100°C DIELECTRIC STRENGTH................................................ 350V RMS (all terminals to case) INSULATION RESISTANCE ............................................ 100M-Ohms (all terminals to case) ALTITDUE ......................................................................... Operating: sea level to 60,000 ft. VIBRATION ....................................................................... Operating: 0.06 in. D.A., 10 to 55 Hz (Method 201 of MIL-STD-202) SHOCK .............................................................................. Operating: 50g, 11 m-sec half sine pulse Method 213, Condition A of MIL-STD-202. MOISTURE RESISTANCE ............................................... Will meet Method 106 of MIL-STD-202 and Method 507.1 Proc. 1 of MIL-STD-810. OPERATING HUMIDITY................................................... 0% to 95% RH ATTITUDE ......................................................................... Unit will perform as specified when mounted in any position. CASE MATERIAL.............................................................. Molded plastic meets UL flammability rating 94V-0 WEIGHT ............................................................................ 12 oz. max.
NOTES: 1. NORMALLY SUPPLIED WITH 5 PIN TERMINAL BARRIER STRIP. MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, .325 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 16 AWG AND WIRE LUGS TO .250 IN. WIDE. AVAILABLE WITH 6 PIN OPTIONAL CONNECTOR MS3112E-10-6P OR EQUIVALENT. ADD LETTER -C AFTER PART NUMBER FOR CONNECTOR OPTION.
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-S461-1001
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT LEVEL CONTROLLER SERIES 870
PART NO.
RANGE AMPS AC
870-1............................ 1 870-2............................ 2 870-5............................ 5 870-10..........................10 870-15.......................... 15 870-20.......................... 20
RANGE AMPS AC
PART NO.
870-50 ...................................... 50 870-100 ................................... 100 870-150 ................................... 150 870-200 ................................... 200 870-250 ................................... 250 870-300 ................................... 300
INPUT CURRENT RANGES (FULL SCALE) .............................. See Table Above FREQUENCY.................................................................... 47 to 63Hz OVERLOAD RATING....................................................... 500A for 30 sec/hr OUTPUT RELAY CONTACT RATINGS .......................................... SPDT; Actuated at set point 10 AMPS @ 250 Vac or 24 Vdc * SET POINT ..................................................................... Adjustable 20 to 100% FS SET POINT REPEATABILITY.......................................... ±0.5% of range RESET............................................................................... Automatic when current falls 20% below set point (typical) SET POINT INDICATOR LIGHT ...................................... On when current is at or above set point (Relay energized) RESPONSE....................................................................... 500 m-sec (typical) TIME DELAY (OPTIONAL) .............................................. Adjustable 0.5 sec to 15 sec * Set point normally at approx. mid range when shipped from factory. Set point adjusted by factory to desired level upon request. Set point and time delay adjustment- turn clockwise to increase. SUPPLY (AC LINE) VOLTAGE (STANDARD) ................................................. 115 Vac (105 min. - 130 max.) (OPTIONAL) ................................................... 220 Vac (200 min. - 260 max.) FREQUENCY.................................................................... 47 thru 63 Hz BURDEN ........................................................................... 4Va max. Contact Factory for 440Vac or 400Hz operations.
TERMINAL IDENTIFICATION IDENTIFICATION 1-2 3 4-5-6
AC SUPPLY VOLTAGE CASE GROUND RELAY CONTACTS
ENVIRONMENTAL AND PHYSICAL SPECIFICATION OPERATING TEMPERATURE RANGE.......................... -20°C to +70°C ISOLATION ....................................................................... Input, Relay, Case DIELECTRIC STRENGTH................................................ 2000V RMS WEIGHT ............................................................................ 2 lbs. max.
NOTE: MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 12 AWG AND WIRE LUGS UP TO 5/16 IN. WIDE
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- 870
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 6946739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT CONTROLLER SERIES 871
PART NO.
RANGE AMPS AC
871-1............................1 871-2............................2 871-5............................ 5 871-10..........................10 871-15.......................... 15 871-20.......................... 20
RANGE AMPS AC
PART NO.
871-50 ......................................50 871-100 ................................... 100 871-150 ................................... 150 871-200 ................................... 200 871-250 ................................... 250 871-300 ................................... 300
INPUT INPUT (LOAD CURRENT) CURRENT RANGES (FULL SCALE) .............................. See Table Above FREQUENCY.................................................................... 47 to 400Hz OVERLOAD...................................................................... 250A for 100AMP FS & below 500A FOR 150 AMP FS & above OUTPUT RELAY .............................................................................. SPDT; Actuated at set point RELAY CONTACT RATINGS .......................................... 10 AMPS @ 250 Vac or 24 Vdc * SET POINT ..................................................................... Adjustable 20 to 100% FS SET POINT REPEATABILITY.......................................... ±0.5% of range RESET............................................................................... Automatic when current falls 20% below set point SET POINT INDICATOR LIGHT ...................................... On when current is at or above set point (Relay energized) RESPONSE....................................................................... 500 m-sec (typical) TIME DELAY (OPTIONAL) .............................................. Adjustable 0.5 sec to 20 sec * Set point normally at mid range when shipped from factory. User desired set point can be factory set upon request. Set point and time delay adjust - turn clockwise to increase. SUPPLY (AC LINE) VOLTAGE ........................................................................ 115 Vac (105 min. - 130 max.) or 220 Vac (200 min. - 260 max.) or 440 Vac (390 min. - 490 max.) FREQUENCY RANGE...................................................... 47 thru 400 Hz ENVIRONMENTAL AND OTHER SPECIFICATIONS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C ISOLATION ....................................................................... Input, Relay, Case DIELECTRIC STRENGTH................................................ 2000V RMS WEIGHT ............................................................................ 2 lbs. max.
TERMINAL IDENTIFICATION 1-2 3 4-5-6
AC SUPPLY VOLTAGE CASE GROUND RELAY CONTACTS
NOTE: MOLDED TERMINAL BLOCK WITH 6-32 TERMINAL SCREWS, 7/16 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 12 AWG AND WIRE LUGS UP TO 5/16 IN.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- 871
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 6946739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT CONTROLLER SERIES 882
PART NO.
CURRENT RANGE AMPS AC
882-1............................ .2 TO 1 882-2............................ .4 TO 2 882-5............................ 1 TO 5 882-10.......................... 2 TO 10 882-15.......................... 3 TO 15 882-20.......................... 4 TO 20
CURRENT RANGE AMPS AC
PART NO.
882-50...................................... 882-100.................................... 882-150.................................... 882-200.................................... 882-250.................................... 882-300....................................
10 TO 50 20 TO 100 30 TO 150 40 TO 200 50 TO 250 60 TO 300
INPUT CURRENT RANGE ........................................................... See Table FREQUENCY .................................................................... 50 to 400Hz OVERLOAD CURRENT CONTINUOUS.......................... 250 Amps or two times range, whichever is greater OVERLOAD CURRENT SURGE ..................................... 10,000 Amps for 6 cycles OUTPUT RELAY CONTACT S.P.D.T. ............................................. Actuated at and above set point SWITCH RATING.............................................................. 2 Amps @ 250Vac or 30Vdc (Resistive Load) * TRIP POINT .................................................................... Adjustable over current range TRIP POINT REPEATABILITY......................................... ±0.5% of range RESET ............................................................................... Automatic @ 20% below set point RESPONSE TIME ............................................................. 500 m-sec max. TIME DELAY (OPTIONAL) .............................................. Adjustable 0.500 m-sec to 15 sec. ** INDICATOR................................................................... LED-on at & above trip POWER SUPPLY (AC LINE) VOLTAGE ........................................................................ 115Vdc VOLTAGE RANGE ........................................................... 105 to 125Vac max. FREQUENCY .................................................................... 47 to 63 Hz BURDEN ........................................................................... 4VA typical ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .......................... -20°C to +70°C STORAGE TEMPERATURE RANGE.............................. -40°C to +85°C DIELECTRIC STRENGTH ................................................ 2000V RMS CASE MATERIAL............................................................. Molded plastic meets UL flammability rating 94V-0 WEIGHT ............................................................................ TBD
DELAY OPTION ADD “-T” TO MODEL NO. FOR THE TIME DELAY OPTION.
TERMINAL BARRIER
NOTES: * TRIP POINT SET AT MID RANGE WHEN SHIPPED. SET POINT AND DELAY ADJUSTMENTS - TURN CLOCKWISE TO INCREASE. SET POINT & DELAY ADJUSTED BY FACTORY TO DESIRED LEVELS UPON REQUEST. ** LIGHT EMITTING DIODE (LED) COLOR RED INDICATES THE ON/OFF STATUS OF THE UNIT.
5-40 SCREWS 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE LUG UP TO 9/32” WIDE.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- 882
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT OPERATED SWITCHES SPLIT CORE AAC MODEL
RANGE
ADJUSTABLE
OUTPUT
ACS-CAJ-150 ACS-OAJ-150 ACS-CNO-250 ACS-ONO-250
1.5-150A 1.5-150A 1.5-250A 1.5-250A
YES YES NO NO
NORMALLY CLOSED NORMALLY OPEN NORMALLY CLOSED NORMALLY OPEN
SPECIFICATIONS Power Supply Output Output Rating
Off State Leakage Response Time Set Point Range Hysteresis
NONE--Self-powered Magnetically Isolated Solid State Switch N.O. Version: 0.2A @ 240VAC or VDC N.C. Version: 0.2A @ 130VAC or VDC Not polarity sensitive None 0.120 Second 1.5-150A 5% of Setpoint
Overload
Model Continuous Normally Open 250A Normally Closed 150A
6 Sec 500A 400A
1 Sec 1000A 1000A
Isolation Voltage Frequency Range Sensing Aperture Case Environmental Listing
UL Listed to 1,270VAC, tested to 5,000VAC 6-100Hz 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -58 to 149° F (-50 to 65° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada); CE
HOW TO ORDER ORDE R ACSACSRANGE
ACSACSRANGE
-150 – 1.5 TO 150A
-250 – 1.5 TO 250A
OUTPUT
OUTPUT
-CAJ – ADJUSTABLE – NORMALLY CLOSED -OAJ – ADJUSTABLE – NORMALLY OPEN
-CNO – NON-ADJUSTABLE – NORMALLY CLOSED -ONO – NON-ADJUSTABLE – NORMALLY OPEN
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- ACS
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT OPERATED OPERATED SWITCHES SPLIT CORE AAC MODEL
RANGES
RANGE SELECT.
OUTPUT
ACS-CAJ-200
1.5-6A 6-40A 40-200A
YES
NORMALLY CLOSED
ACS-OAJ-200
1.5-6A 6-40A 40-200A
YES
NORMALLY OPEN
SPECIFICATIONS Power Supply Supply Output Output Rating
Response Time Set Point Range Hysteresis
NONE--Self-powered Isolated Solid State Switch 1.0A @ 240VAC (Standard Units) 15A @ 120VDC, 10A @ 240VDC (-15 Option) NO: None NC: 2.5mA 0.04 to 0.120 Second 1.5-6, 6-40 & 40-200A 5% of Setpoint
Overload (1 1) (2 2) (3 3)
Current 1-6A 6-40A 40-200A
Isolation Isola tion Voltage Frequency Range Sensing Aperture Case Environmental Listing
UL Listed to 1,270VAC, tested to 5,000VAC 6-100Hz, works on VFDs 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -58 to 149° F (-50 to 65° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada); CE
Off State Leakage
Continuous 150A 150A 210A
6 Sec 400A 500A 800A
1 Sec 600A 800A 1200A
HOW TO ORDER ACSACSRANGE -200 – 1.5 TO 6A – 6 TO 40A – 40 TO 200A RANGE SELECTABLE
OUTPUT -CAJ – NORMALLY CLOSED -OAJ – NORMALLY OPEN
YES YES
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- ACSACS- 3
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT SWITCHES SPLIT CORE SELFSELF- CALIBRATING AAC MODEL
RANGE
FUNCTION
OUTPUT
ACS-CO-150 ACS-CU-150 ACS-CB-150 ACS-OO-150 ACS-OU-150 ACS-OB-150
2.8-150A 2.8-150A 2.8-150A 2.8-150A 2.8-150A 2.8-150A
OVERLOAD UNDERLOAD OVER/UNDER OVERLOAD UNDERLOAD OVER/UNDER
NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN
SPECIFICATIONS Power Supply Output Output Rating
Off State Leakage Response Time Set Point Range Set Point
NONE--Self-powered Magnetically Isolated Solid State Switch N.O. Version: 0.2A @ 240VAC or VDC N.C. Version: 0.2A @ 130VAC or VDC Not polarity sensitive None 0.20 Seconds 2.8-150A Overload: +15% of load
Underload: -15% of load Operating Window +/- 15% of Setpoint
HOW TO ORDER ORD ER
Hysteresis
5% of Setpoint
Overload
Model ALL
Isolation Voltage Volta ge Frequency Range Sensing Aperture Case Environmental Listing
UL Listed to 1,270VAC, tested to 5,000VAC 6-100Hz 0.85” (21.5mm) sq. UL 94V-0 Flammability rated -58 to 149° F (-50 to 65° C), 0-95% RH, non-condensing UL 508 Industrial Control Equipment (USA & Canada); CE
Continuous 150A
6 Sec 500A
1 Sec 1000A
ACS-XX-150 (2.8A TO 150A –only) -XX
FUNCTION
OUTPUT
-CO -CU -CB
OVERLOAD UNDERLOAD OVER/UNDER
NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED
-OO -OU - OB
OVERLOAD UNDERLOAD OVER/UNDER
NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- ACSACS- SC
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC CURRENT CONTROLLER SERIES 881
CURRENT RANGE OVERLOAD MODEL NUMBER AMPS AC AMPS AC 881-12.............................2 - 12 ........................................... 250 881-50..................... .......8 - 50 .......................................... 250 881-120................... ...40 - 120 ........................................... 250 881-250................... .100 - 250 ........................................... 300 INPUT CURRENT RANGE........................................................... See Table FREQUENCY.................................................................... 50 to 400 Hz OVERLOAD CURRENT CONTINUOUS.......................... See Table OVERLOAD CURRENT SURGE ..................................... 10,000 Amps for 6 cycles OUTPUT RELAY CONTACT (S.P.D.T.) .......................................... Actuated at and above set point CONTACT RATING.......................................................... 2 Amps @ 250Vac or 3Vdc (Resistive Load) * TRIP POINT.................................................................... Adjustable over current range RESET (AUTOMATIC) ..................................................... 5% of range below trip point typical RESPONSE TIME............................................................. 200 m-sec max. ** INDICATOR................................................................... LED-on at & above trip POWER SUPPLY (AC LINE) SUPPLY VOLTAGE ........................................................ 115Vac (95 min. - 126 max.) FREQUENCY.................................................................... 47 to 63 Hz BURDEN ........................................................................... 0.9VA ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -20° to +70°C STORAGE TEMPERATURE RANGE ............................. -40° to +85°C DIELECTRIC STRENGTH................................................ 2000V RMS CASE MATERIAL............................................................. Molded plastic meets UL flammability rating 94V-0 WEIGHT ............................................................................ 6 oz. max.
NOTES: TERMINAL BARRIER 5-40 SCREWS 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE LUG UP TO 9/32” WIDE.
* TRIP POINT SET AT MID RANGE WHEN SHIPPED. TURN ADJUSTABLE TRIP POINT DIAL CLOCKWISE TO INCREASE SET POINT LEVEL. SET POINT ADJUSTED BY FACTORY TO DESIRED LEVELS UPON REQUEST. ** LIGHT EMITTING DIODE (LED) COLOR RED INDICATES THE ON/OFF STATUS OF THE UNIT.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- 881
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT CONTROLLER SERIES 880B
CURRENT RANGE OVERLOAD AMPS AC AMPS AC MODEL NUMBER NU MBER 880B-12....................... 2 – 12 .......................................... 250 880B-50................... .. 8 – 50 ......................................... 250 880B-120 ......................40 – 120 ...................................... 250 880B-250.......................100 – 250 .................................... 300 INPUT CURRENT RANGE .......................................................... FREQUENCY ................................................................... OVERLOAD CURRENT CONTINUOUS ......................... OVERLOAD CURRENT SURGE.....................................
See Table 50 to 400 Hz See Table 10,000 Amps for 6 cycles
OUTPUT SOLID STATE SWITCH (S.P.D.T.N.O.)........................... SWITCH RATING ............................................................. MINIMUM SWITCH VOLTAGE ....................................... * TRIP POINT.................................................................... RESET (AUTOMATIC)..................................................... RESPONSE TIME ............................................................ ** INDICATOR ..................................................................
Actuated at and above set point 60mA, 120V, ac or dc max. 3.5V @ 0.5mA to 4.5V @ 60mA Adjustable over current range 5% of range below trip point typical 200 m-sec max. LED-on at & above trip point
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -20° to +70°C STORAGE TEMPERATURE ........................................... -40° to +85°C DIELECTRIC .................................................................... 2000V RMS CASE MATERIAL ............................................................ Molded plastic meets UL flammability rating 94V-0 WEIGHT............................................................................ 6 oz. max.
NOTES: * TRIP POINT SET AT MID RANGE WHEN SHIPPED. TURN ADJUSTABLE TRIP POINT DIAL CLOCKWISE TO INCREASE SET POINT LEVEL. SET POINT ADJUSTED BY FACTORY TO DESIRED LEVELS UPON REQUEST. ** LIGHT EMITTING DIODE (LED) COLOR RED IS IN SERIES WITH THE SOLID STATE SWITCH INDICATES THE ON/OFF STATUS OF THE UNIT.
TERMINAL BARRIER 5-40 SCREWS 3/8” CENTER TO CENTER SPACING ACCEPTS WIRE LUG UP TO 9/32” WIDE.
AAC Code Ident. No. 15948
Drawing Number
R ev.
700700- 880B
B
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC CURRENT LEVEL DETECTOR PART NUMBER S212S212- 850 INPUT RANGE ............................................................................. FREQUENCY ................................................................... OVERLOAD CURRENT CONTINOUSE ......................... OVERLOAD CURRENT SURGE.....................................
0 to 75Aac 400Hz ±10% 100Aac 500Aac for 6 cycles
OUTPUT RELAY CONTACT (SPDT) .............................................. Energized at & above set point CONTACT RATING.......................................................... 1 Amp Resistive @ 28V or 5V 400Hz 200mA Inductive 100mA Lamp TRIP POINT(AS CURRENT DECREASES) ................... 0.5Aac ±0.075Aac TRIP POINT REPEATABILITY........................................ ± .01Aac RESET .............................................................................. Automatic when input current rises approximately 0.1Aac above trip point RESPONSE TIME ............................................................ 200 m-sec max. OUTPUT ISOLATION....................................................... 350V RMS @ sea level POWER SUPPLY SUPPLY VOLTAGE ........................................................ 28Vdc, nominal CURRENT DRAIN ............................................................ 70mA max. REVERSE POLARITY PROTECTION ............................ 100µA max. current drain without damage ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ......................... -55°C to +70°C STORAGE TEMPERATURE RANGE ............................. -55°C to +85°C DIELECTRIC STRENGTH ............................................... 350V RMS MIL-STD-202 Method 301 MOUNTING ...................................................................... Rigid in any position INSULATION RESISTANCE ............................................ 200 M-Ohms min. MIL-STD-202 Method 302 Test Condition A WEIGHT............................................................................ 16 oz. max. (1 oz mating connector) CATEGORY
DO-160 ENVIRONMENT
MATE WITH PT06A-10-65 (SR) (OR EQUIVALENT)
TEMPERATURE & ALTITUDE HUMIDITY VIBRATION EXPLOSION WATERPROOFNESS HYDRAULIC FLUID SAND AND DUST FUNGUS RESISTANCE SALT SPRAY MAGNETIC EFFECT POWER INPUT (NORMAL OPERATING CONDITIONS ONLY) VOLTAGE SPIKES AUDIO FREQUENCY CONDUCTED SUSCEPTIBILITY ELECTROMAGNETIC COMPATIBILITY
AAC Code Ident. No. 15948
A2D2 A CJL E X X X F S X ABZ AB Z A
Drawing Number
Rev.
700700- S212S212- 850
J
A AC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
A.C. VOLTAGE SENSOR SERIES 108 INPUT VOLTAGE CONTINUOUS RANGE Vac OVERLOAD Vac MODEL NO. 108-50 ................................ 0 to 50..............................................................100 108-130 ................................ 0 to 130............................................................180 108-150 ................................ 0 to 150............................................................200 108-270 ................................ 0 to 270............................................................380 108-500 ................................ 0 to 500............................................................700 108-600 ................................ 0 to 600............................................................800 INPUT VOLTAGE RANGE................................................................................ FREQUENCY ........................................................................................ FREQUENCY RANGE .......................................................................... BURDEN................................................................................................ OVERLOAD Vac....................................................................................
See Table 60Hz (400Hz Model Available) * 57 to 63Hz 3mA max. See Table
OUTPUT VOLTAGE SIGNAL................................................................................ 0 to +5Vdc FS (Full Scale) 4 to 20mA Output Models Available ACCURACY........................................................................................... ±0.5% FS (±25mV) RESPONSE (0 to 90%) ......................................................................... 300 m-sec max. RIPPLE .................................................................................................. 25mV RMS max. TEMPERATURE COEFFICENT ........................................................... ±0.02% FS/°C max. REPEATABILITY ................................................................................... ± 0.1% FS OUTPUT IMPEDANCE ......................................................................... 4000 Ohms max. POWER SUPPLY SUPPLY VOLTAGE............................................................................... Self excited ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE............................................... STORAGE TEMPERATURE RANGE .................................................. INSULATION RESISTANCE................................................................. DIELECTRIC STRENGTH .................................................................... WEIGHT ................................................................................................
TERMINAL IDENTIFICATION 1. 2. 3. 4.
AC VOLTAGE INPUT AC VOLTAGE INPUT OUTPUT (+) OUTPUT (RTN)
Code Ident. No. 15948
TERMINAL SCREWS 5-40 3/8 CENTER TO CENTER WIRE SIZES TO 14 AWG WIRE LUGS TO .281 WIDE.
- 20° C to +70°C - 55°C to +85°C 200 M-Ohms (all terminals to case) 1000V RMS 10 oz. max.
* NOTE: ADD SUFFIX -400 TO MODEL NO. FOR 400Hz OPERATION.
AAC
Drawing Number
Rev.
700-108
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
A.C. VOLTAGE TRANSDUCER SERIES 108X 4 TO 20mA 2 WIRE OPERATION INPUT VOLTAGE CONTINUOUS RANGE Vac OVERLOAD Vac PART NO. 108X-50 ................................ 0 to 50..............................................................100 108X-130 ................................ 0 to 130............................................................180 108X-150 ................................ 0 to 150............................................................200 108X-270 ................................ 0 to 270............................................................380 108X-500 ................................ 0 to 500............................................................700 108X-600 ................................ 0 to 600............................................................800 INPUT VOLTAGE RANGE................................................................................ FREQUENCY ........................................................................................ FREQUENCY RANGE .......................................................................... BURDEN................................................................................................ OVERLOAD Vac....................................................................................
See Table 60Hz (400Hz Model Available) * 57 to 63Hz 3mA max. See Table
OUTPUT CURRENT SIGNAL (2 WIRE OPERATION)........................................ CURRENT SIGNAL @ OVERLOAD..................................................... ACCURACY........................................................................................... RIPPLE (RMS)....................................................................................... RESPONSE (0 to 90%) ......................................................................... TEMPERATURE COEFFICENT ........................................................... LOAD RESISTANCE (RL)..................................................................... LOAD RESISTANCE RANGE............................................................... PROTECTION .......................................................................................
4 to 20mAdc FS (Full Scale) 30mA typical ±0.5% FS (±0.1mA) 0.5% FS (±0.1mA RMS) 300 m-sec max. ±0.020% FS/°C max. 250 Ohms nominal 0 to 1100 Ohms (See Table II) Reverse Polarity Protected
POWER SUPPLY (PS) SUPPLY VOLTAGE............................................................................... 15Vdc nominal CURRENT DRAIN................................................................................. 20mA SUPPLY VOLTAGE RANGE................................................................. 10 to 35Vdc (See Table II) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE............................................... STORAGE TEMPERATURE RANGE .................................................. INSULATION RESISTANCE................................................................. DIELECTRIC STRENGTH .................................................................... WEIGHT ................................................................................................
- 20° C to +70°C - 55°C to +85°C 200 M-Ohms (all terminals to case) 1000V RMS 10 oz. max.
TERMINAL IDENTIFICATION 1. 2. 3. 4.
AC VOLTAGE INPUT AC VOLTAGE INPUT OUTPUT (+) OUTPUT (RTN)
TERMINAL SCREWS 5-40 3/8 CENTER TO CENTER WIRE SIZES TO 14 AWG WIRE LUGS TO .281 WIDE.
Code Ident. No. 15948
TABLE II SUPPLY (PS) VS LOAD RESISTANCE (RL) SUPPLY 15 Vdc 20Vdc 25Vdc 30Vdc 32Vdc
LOAD RESISTANCE 0 to 250 Ohms 0 to 500 Ohms 0 to 750 Ohms 0 to 1000 Ohms 0 to 1100 Ohms
* NOTE: ADD SUFFIX -400 TO PART NO. FOR 400Hz OPERATION.
AAC
Drawing Number
Rev.
700-108X
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
A.C. VOLTAGE SENSOR MODEL S190-108
PART NUMBER S190-108-130 S190-108-150 S190-108-270 S190-108-300 S190-108-600
INPUT VOLTAGE RANGES
MAXIMUM OVERVOLTAGE
0 to 130 Vac 0 to 150 Vac 0 to 270 Vac 0 to 300 Vac 0 to 600 Vac
180 Vac 180 Vac 380 Vac 380 Vac 700 Vac
OUTPUT VOLTAGE.............................................................................. 0 to 10Vdc AC INPUT CURRENT DRAIN............................................................... 3mA, max. OUTPUT IMPEDANCE ......................................................................... 10K-Ohms, max. FREQUENCY ........................................................................................ 47 to 63Hz OUTPUT RIPPLE .................................................................................. 3% F.S. RMS, max. ACCURACY........................................................................................... ±2% F.S. REPEATABILITY ................................................................................... ½% F.S. RESPONSE ........................................................................................... 200m-sec., max. OPERATING TEMPERATURE............................................................. 0°C to +60°C STORAGE TEMPERATURE ................................................................ -25°C to +85°C TEMPERATURE COEFFICIENT .......................................................... ± 0.05% F.S./°C WEIGHT ................................................................................................ 10 oz.
TERMINAL IDENTIFICATION 1. 2. 3. 4.
AC INPUT (HI) AC INPUT (RTN) DC OUTPUT (HI) DC OUTPUT (RTN)
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-S190-108
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC VOLTAGE TRANSDUCER SERIES V SELF - POWERED
PART
INPUT
NUMBER
VOLTAGE
TRANSIENT OVERLOAD APPLICATION
SEC/HR
V-120....................................0 to 150V ........................... 115/120V ............................. 220V V-220....................................0 to 300V ........................... 208/220/240V ...................... 375V V-440....................................0 to 500V ........................... 440/480V ............................. 650V INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ LINEAR OVER RANGE............................................................. TRANSIENT CAPABILITY ........................................................ DIELECTRIC.............................................................................. BURDEN....................................................................................
Vac See Table 47 to 1000Hz 20% of Range See Table 2KV RMS, 60Hz, 1 min. 2VA max.
OUTPUT CURRENT SIGNAL................................................................... ACCURACY * (60Hz)................................................................. (47 to 1000Hz).................................................... RIPPLE ...................................................................................... RESPONSE (0 to 99%) ............................................................. LOAD RESISTANCE RANGE................................................... CALIBRATION ADJUSTMENT ................................................. STABILITY PER YEAR..............................................................
0 to 1mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 0 to 11K-Ohms ±10% FS ±0.1% FS
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................. STORAGE TEMPERATURE .................................................... ISOLATION................................................................................ INSULATION RESISTANCE..................................................... SURGE CAPABILITY ................................................................ WEIGHT ...................................................................................
-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.
* INCLUDES COMBINED WORSE CASE EFFECTS OF TEMPERATURE AND LOAD CHANGES. TERMINAL IDENTIFICATION 1. 2. 3. 4.
OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT
NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.
ADD “-E” AND OR “-F” TO PART NUMBER FOR SPECIAL OPTIONS
“-E” OUTPUT VOLTAGE OPTION ADD -E PLUS DESIRED OUTPUT VOLTAGE FROM 0 TO A MAX OF 10
“-F” CALIBRATION FREQ. OPTION ADD -F PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-V
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC VOLTAGE TRANSDUCER SERIES VX 4 TO 20mA LOOP - POWERED
PART NUMBER
INPUT VOLTAGE
TRANSIENT OVERLOAD APPLICATION
SEC/HR
VX-120 .................................0 to 150V ........................... 115/120V ............................. 220V VX-220 .................................0 to 300V ........................... 208/220/240V ...................... 375V VX-440 .................................0 to 500V ........................... 440/480V ............................. 650V INPUT RANGE ...................................................................................... FREQUENCY ............................................................................ LINEAR OVER RANGE............................................................. TRANSIENT CAPABILITY ........................................................ DIELECTRIC.............................................................................. BURDEN....................................................................................
Vac See Table 47 to 1000Hz 20% of Range See Table 2KV RMS, 60Hz, 1 min. 2VA max.
OUTPUT CURRENT SIGNAL................................................................... ACCURACY * (60Hz)................................................................. (47 to 1000Hz).................................................... RIPPLE ...................................................................................... RESPONSE (0 to 99%) ............................................................. LOAD RESISTANCE................................................................. LOAD RESISTANCE RANGE...................................................
4 to 20mA FS (Full Scale) ±0.25% FS ±0.5% FS. 0.5% FS peak max. 400m-sec. max. 250 Ohms Nominal 0 to 250 Ohms @ 15Vdc 0 to 1100 Ohms @ 32Vdc PROTECTION ........................................................................... Reverse Polarity Protected CALIBRATION ADJUSTMENT ................................................. ±10% of FS STABILITY PER YEAR.............................................................. ±0.1% FS max. POWER SUPPLY SUPPLY VOLTAGE................................................................... +15Vdc Nominal CURRENT DRAIN..................................................................... 20mA SUPPLY VOLTAGE RANGE..................................................... 10 to 35Vdc
TERMINAL IDENTIFICATION 1. 2. 3. 4.
OUTPUT SIGNAL (+) OUTPUT (RTN) AC INPUT AC INPUT
NOTE: MOLDED TERMINAL BLOCK WITH 8-32 SCREWS 7/16 IN. CENTER TO CENTER SPACING ACCEPTS WIRE SIZES UP TO 12 AWG AND LUGS UP TO 3/8 IN. WIDE.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE................................................. STORAGE TEMPERATURE .................................................... ISOLATION................................................................................ INSULATION RESISTANCE..................................................... SURGE CAPABILITY ................................................................ WEIGHT ...................................................................................
-20° to +70°C -55° to +85°C Input/Output/Case 100m-Ohms min. @ 500Vdc IEEE SWC transient test 16 oz. Typ.
ADD “-F” TO PART NUMBER PLUS DESIRED CALIBRATION FREQ. FROM 47 TO 1000Hz FOR CALIBRATION FREQ. OPTION.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-VX
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC VOLTAGE TRANSDUCER PART NUMBER 101M3-150
INPUT VOLTAGE RANGE ............................................................................. FREQUENCY ................................................................... BURDEN........................................................................... OVERVOLTAGE CAPABILITY ........................................
90 to 150Vac RMS 60Hz 1 Va Typical 200 Vac max.
OUTPUT SIGNAL VOLTAGE SIGNAL (V min. to V max.) ............................. ACCURACY...................................................................... RESPONSE ...................................................................... RIPPLE ............................................................................. TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE ....................................................
0 to 5Vdc FS (Full Scale) ±0.5% FS (±25mV) Within 0.5 cycle of input frequency 1% 50mV RMS max. ± 0.08% FS/°C max. (±4mVdc /°c) 2.5 K-Ohms max.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -40° to +70°C STORAGE TEMPERATURE RANGE ............................. -55° to +100°C DIELECTRIC STRENGTH ............................................... 300 V-RMS INSULATION RESISTANCE............................................ 100 M Ohms @ 500Vdc VIBRATION....................................................................... Operating, meet or exceed Method 201A of MIL-STD-202F and Method 514.3 cat. 4 of MILSTD-810C. SHOCK ............................................................................. Operating: 50g, 11 m-sec half sine pulse (meet or exceed method 213B, Condition A of MIL-STD-202F) MOISTURE RESISTANCE .............................................. Meet or exceed Method 106 of MIL-STD-202F and Method 507.2 proc. 1 of MIL-STD-810C. OPERATING HUMIDITY .................................................. 0% to 95% RH WEIGHT ........................................................................... 20 oz. max.
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
A.C. INPUT HI A.C. INPUT LO CASE GROUND OUTPUT (RTN) OUTPUT (+)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-101M3
E
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
AC VOLTAGE TRANSDUCER SERIES 102M3 INPUT VOLTAGE RANGE V min. V max. PART NUMBER 102M3-175........................................... 90 TO 175 102M3-130........................................... 105 TO 130 102M3-225........................................... 175 TO 225
INPUT VOLTAGE RANGE ............................................................................. FREQUENCY ................................................................... BURDEN........................................................................... OVERVOLTAGE CAPABILITY ........................................
OUTPUT SIGNAL VOLTAGE SIGNAL (V min. to V max.) ............................. ACCURACY...................................................................... RESPONSE ...................................................................... RIPPLE ............................................................................. TEMPERATURE COEFFICIENT ..................................... OUTPUT IMPEDANCE ....................................................
See Table 340 to 440Hz 1 Va Typical 200 Vac max. for 175, 130 ranges 300 Vac max. for 225 range
0 to 5Vdc FS (Full Scale) ±0.5% FS (±25mV) Within 1 cycle of input frequency 50mV RMS max. ± 0.08% FS/°C max. 2.5 KOhms max.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -40° to +85°C STORAGE TEMPERATURE RANGE ............................. -55° to +100°C DIELECTRIC STRENGTH ............................................... 300 V RMS INSULATION RESISTANCE............................................ 100 MOhms @ 500Vdc VIBRATION....................................................................... Operating, meet or exceed Method 201A of MIL-STD-202F and Method 514.3 cat. 4 of MILSTD-810C. SHOCK ............................................................................. Operating: 50g, 11 m-sec half sine pulse (meet or exceed method 213B, Condition A of MIL-STD-202F) MOISTURE RESISTANCE .............................................. Meet or exceed Method 106 of MIL-STD-202F and Method 507.2 proc. 1 of MIL-STD-810C. OPERATING HUMIDITY .................................................. 0% to 95% RH WEIGHT ........................................................................... 20 oz. max.
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
A.C. INPUT HI A.C. INPUT LO CASE GROUND OUTPUT (RTN) OUTPUT (+)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-102M3
E
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03 fo
.XXX ± .010
AC VOLTAGE SENSOR MODEL 105
PRESET RANGE (VMAX TO VMIN) 390 to 490 VRMS 455 to 505 VRMS 430 to 530 VRMS
MODEL -490 -505 -530
INPUT LINE FREQUENCY...................................................
57 to 63Hz
EXCITATION .........................................................................
Self-excited
BURDEN................................................................................
1Va Typical
OUTPUT FOR PRESET RANGE .........................................
0 to 5Vdc
OUTPUT IMPEDANCE .........................................................
3K Ohms Max.
RESPONSE...........................................................................
Within 1 Cycle of Input Frequency
RIPPLE ..................................................................................
50Mv rms
SUPPRESSION VOLTAGE ACCURACY.............................
± .25% of V Min.
RANGE ACCURACY ............................................................
± 0.5% F.S. Max.
TEMPERATURE COEFFICIENT..........................................
± .08% F.S. per °C
TEMPERATURE RANGE .....................................................
-40 to +85
WEIGHT ................................................................................
20oz. Max.
* OTHER PRESET RANGES AVAILABLE
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
A.C. INPUT HI A.C. INPUT LO CASE GROUND OUTPUT RETURN OUTPUT POSITIVE
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-105
J
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC VOLTAGE TRANSDUCER SERIES S657 RANGE PART NUMBER S657-750 .................................. 0 to ± 750Vdc S657-1200 .................................. 0 to ± 1200Vdc S657-1500 .................................. 0 to ± 1500Vdc
............................... ............................... ...............................
OVERLOAD ± 1500Vdc ± 1500Vdc ± 2000Vdc
INPUT RANGE .............................................................................. See Table OVERLOAD CONTINUOUS............................................. See Table OVERLOAD TRANSIENT................................................. 6Kvdc FOR 100µ µ -sec ISOLATION ....................................................................... 5Kv RMS 60Hz FOR 1 min. BURDEN @ FULL SCALE................................................ 3mA typ. for 750V range 4mA typ. for 1200V range 3.3mA typ. for 1500V range OUTPUT CURRENT SIGNAL........................................................... 4 to 20mAdc FS (Full Scale) ACCURACY....................................................................... ±1% FS (±0.2mA max.) over temp. range POLARITY SENSING ....................................................... 4 to 20mAdc proportional to the absolute. Value of the input voltage. RESPONSE (10 to 90%) ................................................... 5m-sec. max. LOAD RESISTANCE......................................................... 250 Ohms nominal LOAD RESISTANCE RANGE .......................................... 0 to 500 Ohms CURRENT SIGNAL @ OVERLOAD ................................ 22mAdc typ. NOISE FILTERING ........................................................... 1 TO 100KHZ ISOLATION MODE REJECTION RATIO ......................... >85db @ 10KHZ POWER SUPPLY SUPPLY VOLTAGE .......................................................... +24 ± 2Vdc CURRENT DRAIN............................................................. 50mA max. TRANSIENT ...................................................................... 60Vdc 5 sec. 100Vdc 1m-sec PROTECTION................................................................... Reverse Polarity Protected ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ........................................ -40°° to +65°C STORAGE TEMPERATURE ............................................ -40°° to +71°C OPERATION HUMIDITY................................................... 0 to 100% relative humidity SHOCK & VIBRATION...................................................... 20g shock, 10g @ 5-200Hz INSULATION RESISTANCE ............................................ 500M-Ohms @ 500Vdc DIELECTRIC STRENGTH................................................ 1.5Kv RMS 60Hz Continuous. CASE ................................................................................. Thermoplastics Cycolac ABS UL Flammability rating 94V-0. WEIGHT ............................................................................ 1.5 lbs. max. TERMINAL IDENTIFICATION
TERMINAL IDENTIFICATION
J2
J1 J2-A. J2-B. J2-C. J2-D. J2-E.
J1-A. SPARE J1-B. INPUT VOLTS (+/-) J1-C. INPUT VOLTS (+/-)
TRANSDUCER SUPPLIED WITH MATING CONNECTORS AND SOCKET CONTACTS.
Code Ident. No. 15948
SUPPLY VOLTS (+) OUTPUT SIGNAL (+) SUPPLY & OUTPUT (RTN) SPARE SPARE
NOTE: 1.
RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND # 8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.
AAC
Drawing Number
Rev.
700-S657
H
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC VOLTAGE LEVEL DETECTOR PART NUMBER S631-800
INPUT RANGE .................................................... 0 to + 800Vdc OVERLOAD (CONTINUOUS) ................. 1000Vdc (TRANSIENT) 2000Vdc for 25M-sec. TRIP POINT SET POINT............................................... +375Vdc HYSTERESIS ......................................... Auto reset 10Vdc ±5% below trip point REPEATABILITY...................................... ± 0.5% of 400Vdc (-25 to + 70°C) OUTPUT RELAY CONTACT (SPST) ...................... CONTACT RATING ................................. RESPONSE ............................................. DIELECTRIC STRENGTH ......................
Actuated at and above trip point 10amp @ 45Vdc 110M-sec. MAX. 4000 V RMS coil to contact 1000 V RMS between open contact
POWER SUPPLY SUPPLY VOLTAGE ................................ +25 to 45Vdc CURRENT DRAIN.................................... 50mA max. PROTECTION.......................................... Reverse polarity protected ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE ............... -25°C to +75°C STORAGE TEMPERATURE ................... -40°C to +85°C SHOCK & VIBRATION ............................ IAW ADTRANZ Doc. ABB-ES-091291-1 OPERATING HUMIDITY ......................... 0 to 95% Relative Humidity INSULATION RESISTANCE .................. 500 M-ohms @ 500Vdc DIELECTRIC STRENGTH ...................... 3.3Kv RMS 60Hz CASE ........................................................ Thermoplastics Cycolac ABS Meets UL Flammability Rating 94 V-0 WEIGHT .................................................. 1.5 lbs. max.
NOTE: 1. TERMINALS : 1 -- 2 : 6-32 SCREWS TORQUE 8 IN-LB MAX. 3 - 6 : 4-40 SCREWS TORQUE 8 IN-LB MAX. 2. PART TO BE IDENTIFIED WITH ADTRANZ PART NUMBER & REVISION LEVEL IN ACCORDANCE WITH SAE AS478-30, LATEST REVISION. CHARACTER HEIGHT SHALL BE .50 INCH MAX. APPROX. WHERE SHOWN. 3. REFERENCE DOCUMENT NO. E301-010.RFP (XVL). 4. RECOMMENDED MOUNTING HARDWARE #8 SCREW, #8 SPLIT LOCKWASHER AND # 8 FLAT WASHER. TORQUE MAXIMUM 18 IN-LB.
Code Ident. No. 15948
AAC
Drawing Number
Rev.
700-S631
E
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
WATT & VAR TRANSDUCER SERIES W & Q
INPUT POWER RANGE .......................................... 0 to Full Scale (FS) See Table I CURRENT RANGE .................................................. 0 to 6.5A RMS - Note (2) (Current Overload 15A Continuous 250A 1 sec/hr) (Current Burden 0.08VA @ 5A) VOLTAGE RANGE (STANDARD)........................... 85 to 140V RMS - Notes (2) & (3) (Voltage Overload 140Vac Continuous) (Voltage Burden 1.5VA @ 120V one phase, all others .04VA/phase) OPTION “B” VOLTAGE RANGE ............................ 0 to 150V RMS - Note (2) (Voltage Overload 175Vac Continuous) (Voltage Burden 0.04VA @ 120V) FREQUENCY ........................................................... 60Hz (50 & 400Hz models available) POWER FACTOR RANGE ...................................... Any (lead or lag) OUTPUT CURRENT SIGNAL.................................. 0 to ±1mAdc FS - Note (2) ACCURACY ............................................................. ±0.25% FS - Note (1) LOAD RESISTANCE................................................ 0 to 10,000 ohms - Note (2) COMPLIANCE VOLTAGE....................................... 11.5Vdc min. 12.5Vdc typical RIPPLE (Peak to Peak) ........................................... 10µA max. RESPONSE ( 0 to 99%) ........................................... 400 m-sec max. TEMPERATURE COEFFICIENT ............................. ±0.005% FS/°C LONG TERM STABILITY......................................... ±0.1% FS/year OUTPUT RANGE ADJUSTMENT ........................... ±3% FS min. - Note (2) (No zero adjustment required) OPTION “B” SUPPLY VOLTAGE........................... 120V RMS Nominal (85 to 140V RMS) SUPPLY BURDEN @ 120V ..................................... 1.5VA max. (0.8PF) SUPPLY FREQUENCY............................................ 60Hz Nominal (55 to 65Hz) ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE ................. -20°C to +70°C STORAGE TEMPERATURE RANGE ..................... -55°C to +75°C OPERATING HUMIDITY.......................................... 0 to 95% ISOLATION............................................................... Input/Supply/Output/Case DIELECTRIC STRENGTH ....................................... 2000V RMS SURGE CAPABILITY .............................................. IEEE Proposed SWC Test OUTPUT PROTECTION .......................................... Withstand 115Vac 5 minutes standard 1Ma output only SHEET 1 OF 2
TABLE I WATT W106 W156 W206 W256 W306
VAR Q106 Q156 Q206 Q256 Q306
FULL SCALE 500W/VAR 1000W/VAR 1000W/VAR 1500W/VAR 1500W/VAR
APPLICATION SIGNAL PHASE 3 PHASE 3 WIRE (Balanced Load and Voltage) 3 PHASE 3 WIRE (Unrestricted Load and Voltage) 3 PHASE 4 WIRE (Unrestricted Load and Balanced Voltage) 3 PHASE 4 WIRE (Unrestricted Load and Voltage)
OPTION “B”: SPECIFY OPTION “B” FOR POWER, SYSTEMS WITH ABNORMAL LINE VOLTAGE VARIATIONS. FOR EXAMPLE: W106-B1; Q106-B1; W156-B1; Q156-B1; ……. ECT.
Code Ident. No. 15948
NOTES: (1) Includes Combined Worse Case Effects Of Load Changes, Input Current, Voltage And Power Factor. (2) Contact Factory For Available Options. (3) Standard Units Do Not Require An Auxiliary Supply Voltage. (4) Molded Terminal Blocks With 8-32 Terminal Screws And 7/16 Inch Center To Center Spacing. Accepts Wire Sizes Up To No. 12 With Lugs To 3/8 Inch Wide.
AAC
Drawing Number
Rev.
700700- W & Q
E
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
WATT & VAR TRANSDUCER SERIES W & Q
TERMINAL CONNECTIONS Hook-Up Diagrams Shown Are Typical Connections For Single And Three Phase Systems In Which Potential Transformers (PT) And Current Transformers (CT) Interface Between Line And Transducer. When The Line Voltage And Current Fall Within The Transducer’s Standard Current And Voltage Range i.e. 0 To 6.5A RMS And 85 To 140V RMS, Then Connections Can Be Made Directly From The Line To The Transducer Without Using PT’s Or CT’s. When The Actual Load Voltage Is Expected To Vary Beyond The Standard Rating Of 85V To 150V RMS, Then A 120Vac Supply Is Necessary Connected To Terminals 7 & 14 As Shown Below. Under These Conditions Option “B” Should Be Specified.
SHEET 2 OF 2
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- W & Q
E
AAC AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC WATT TRANSDUCER SERIES S73 PART
FULL SCALE (FS)
CURRENT
VOLTAGE
SCALE SCALE
FACTOR NUMBER
POWER RANGE
RANGE (ac)
RANGE (ac)
Vdc/KW
S73-10-115 .......................... 0-1KW................................0-10A ...................................0-150V....................... 3.000 S73-25-115 .......................... 0-2.5KW.............................0-25A ...................................0-150V....................... 2.000 S73-50-115 .......................... 0-5KW................................0-50A ...................................0-150V....................... 1.000 S73-100-115 ........................ 0-10KW..............................0-100A .................................0-150V....................... 0.500 S73-150-115 ........................ 0-15KW..............................0-150A .................................0-150V....................... 0.333 S73-200-115 ........................ 0-20KW..............................0-200A .................................0-150V....................... 0.250 S73-300-115 ........................ 0-30KW..............................0-300A .................................0-150V....................... 0.167 S73-500-115 ........................ 0-50KW..............................0-500A .................................0-150V....................... 0.100 S73-10-230 .......................... 0-2KW................................0-10A ...................................0-300V....................... 2.500 S73-25-230 .......................... 0-5KW................................0-25A ...................................0-300V....................... 1.000 S73-50-230 .......................... 0-10KW..............................0-50A ...................................0-300V....................... 0.500 S73-100-230 ........................ 0-20KW..............................0-100A .................................0-300V....................... 0.250 S73-150-230 ........................ 0-30KW..............................0-150A .................................0-300V....................... 0.167 S73-200-230 ........................ 0-40KW..............................0-200A .................................0-300V....................... 0.125 S73-300-230 ........................ 0-60KW..............................0-300A .................................0-300V....................... 0.083 S73-500-230 ........................ 0-100KW............................0-500A .................................0-300V....................... 0.050
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5. 6. 7.
LOAD POTENTIAL (HI) LOAD POTENTIAL (LO) CASE GROUND OUTPUT (RTN) OUTPUT (+) SUPPLY VOLTAGE SUPPLY VOLTAGE
INPUT POWER RANGE....................................................................... See Table FREQUENCY............................................................................ 60Hz ±5% BURDEN ................................................................................... 1VA typical POWER FACTOR RANGE ...................................................... 1 to zero (lead or lag) OUTPUT VOLTAGE SIGNAL .................................................................. 0 to +5VdcFS (Full Scale) ACCURACY.............................................................................. ±2% FS (±100mV) RESPONSE............................................................................... 400m-sec max. RIPPLE (PEAK) ........................................................................ 2% FS max. TEMPERATURE COEFFICIENT ............................................. ±0.15% FS/°C OUTPUT IMPEDANCE............................................................. 2.5K-Ohms max. P.F. PHASE ANGLE ERROR .................................................. ±3°, max. POWER SUPPLY SUPPLY VOLTAGE ................................................................. 105 to 135Vac FREQUENCY............................................................................ 50/60/400Hz BURDEN ................................................................................... 1VA typical ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. -20° to +60°C STORAGE TEMPERATURE RANGE ..................................... -40° to +85°C DIELECTRIC STRENGTH........................................................ 1000Vac INSULATION RESISTANCE .................................................... 200M-Ohms @ 500Vdc ISOLATION ............................................................................... Input/Output/Supply WEIGHT ................................................................................... 3 lbs. Max.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- S73S73- 413
C
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC WATT TRANSDUCER SERIES 415A PART
115 Vac
CURRENT
NUMBER
KW RANGE
RANGE (Aac)
SCALE FACTOR (V/KW)
415A-10-115 ........................0-1KW................................0-10 ..................................... 5 415A-25-115 ........................0-2.5KW.............................0-25 ..................................... 2 415A-50-115 ........................0-5KW................................0-50 ..................................... 1 415A-100-115 ......................0-10KW..............................0-100 ................................... 0.5 415A-150-115 ......................0-12.5KW...........................0-150 ................................... 0.4 415A-200-115 ......................0-20KW..............................0-200 ................................... 0.25 415A-300-115 ......................0-25KW..............................0-300 ................................... 0.20 415A-500-115 ......................0-50KW..............................0-500 ................................... 0.10 230 Vac KW RANGE 415A-10-230 ........................0-2KW................................0-10 ..................................... 2.5 415A-25-230 ........................0-5KW................................0-25 ..................................... 1.0 415A-50-230 ........................0-10KW..............................0-50 ..................................... 0.5 415A-100-230 ......................0-20KW..............................0-100 ................................... 0.25 415A-150-230 ......................0-25KW..............................0-150 ................................... 0.20 415A-200-230 ......................0-40KW..............................0-200 ................................... 0.125 415A-300-230 ......................0-50KW..............................0-300 ................................... 0.10
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
LOAD POTENTIAL (HI) LOAD POTENTIAL (LO) CASE GROUND OUTPUT (RTN) OUTPUT (+)
415A-500-230 ......................0-100KW............................0-500 ................................... 0.05 INPUT INPUT POWER RANGE........................................................... See Table VOLTAGE RANGE 115Vac NOMINAL ............................................................. 80 to 150Vac 230Vac NOMINAL ............................................................. 160 to 300Vac BURDEN.................................................................................... 1Va typ. CURRENT RANGE (Aac) ......................................................... See Table FREQUENCY ............................................................................ 60Hz ±5% POWER FACTOR RANGE....................................................... 1 to zero (lead or lag) PF PHASE ANGLE ERROR ..................................................... ±3° max. OUTPUT SIGNAL OUTPUT VOLTAGE ................................................................. 0 to 5Vdc FS (Full Scale) ACCURACY............................................................................... ±2% FS RIPPLE (PEAK)......................................................................... 3% FS max. RESPONSE............................................................................... 400m-sec max. OUTPUT IMPEDANCE ............................................................. 2.5K-Ohms max. TEMPERATURE COEFFICIENT.............................................. ±0.2% FS/°C max. SCALE FACTOR (VOLTS/KW) ................................................ See Table ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE .................................. 0° to 50°C STORAGE TEMPERATURE RANGE ...................................... -55° to +85°C ISOLATION ............................................................................... Input/Output/Case DIELECTRIC STRENGTH........................................................ 1000V RMS WEIGHT .................................................................................... 1 lb. max,
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-415A
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC WATT TRANSDUCER SERIES 416A PART
FULL SCALE (FS)
CURRENT
POWER RANGE
RANGE
VOLTAGE
SCALE
FACTOR NUMBER
RANGE
Vdc/KW 416A-10-440........................ 0-4KW................................0-10A ...................................0-560V....................... 1.25 416A-25-440........................ 0-10KW..............................0-25A ...................................0-560V....................... 0.50 416A-50-440........................ 0-20KW..............................0-50A ...................................0-560V....................... 0.25 416A-100-440...................... 0-40KW..............................0-100A .................................0-560V....................... 0.125 416A-150-440...................... 0-50KW..............................0-150A .................................0-560V....................... 0.100 416A-200-440...................... 0-80KW..............................0-200A .................................0-560V....................... 0.0625 416A-300-440...................... 0-100KW............................0-300A .................................0-560V....................... 0.0500 416A-500-440...................... 0-200KW............................0-500A .................................0-560V....................... 0.0250 INPUT POWER RANGE....................................................................... CURRENT RANGE................................................................... LOAD VOLTAGE RANGE ....................................................... FREQUENCY............................................................................ BURDEN ................................................................................... POWER FACTOR RANGE ......................................................
KW See Table Aac RMS See Table 320 to 560Vac 60Hz ±5% 1VA typical 1 to zero (lead or lag)
OUTPUT VOLTAGE SIGNAL .................................................................. ACCURACY.............................................................................. RESPONSE............................................................................... RIPPLE (PEAK) ........................................................................ TEMPERATURE COEFFICIENT ............................................. OUTPUT IMPEDANCE.............................................................
0 to +5VdcFS (Full Scale) ±2% FS (±100mV) 400m-sec max. 3% FS max. ±0.2% FS/°C 2.5K-Ohms max.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. 0° to +50°C STORAGE TEMPERATURE RANGE ..................................... -40° to +85°C DIELECTRIC STRENGTH........................................................ 1000Vac INSULATION RESISTANCE .................................................... 200M-Ohms @ 500Vdc ISOLATION ............................................................................... Input/Output/Supply WEIGHT ................................................................................... 3 lbs. Max.
TERMINAL IDENTIFICATION 1. 2. 3. 4. 5.
LOAD POTENTIAL (HI) LOAD POTENTIAL (LO) CASE GROUND OUTPUT (RTN) OUTPUT (+)
AAC Code Ident. No. 15948
Drawing Number
Rev.
700700- 416A
A
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010 AC WATT TRANSDUCER SERIES S217S217- 413 PART
MAX AMPS
RANGE
SCALE(220Vac) NUMBER
(RMS)
KW
FACTOR
V/KW S217-10 ............................... 10.......................................0-2KW ..................................2.5 S217-25 ............................... 25.......................................0-5KW ..................................1.0 S217-50 ............................... 50.......................................0-10KW ................................0.50 S217-100 ............................. 100.....................................0-20KW ................................0.25 S217-150 ............................. 150.....................................0-25KW ................................0.20 S217-200 ............................. 200.....................................0-40KW ................................0.125 PART
MAX AMPS
RANGE
SCALE
(440Vac) NUMBER
(RMS)
KW
FACTOR
V/KW V/KW S217-10 ............................... 10.......................................0-4KW ..................................1.25 S217-25 ............................... 25.......................................0-10KW ................................0.50 S217-50 ............................... 50.......................................0-20KW ................................0.25 S217-100 ............................. 100.....................................0-40KW ................................0.125 S217-150 ............................. 150.....................................0-50KW ................................0.100 S217-200 ............................. 200.....................................0-80KW ................................0.0625 INPUT POWER RANGE....................................................................... KW See Table CURRENT RANGE................................................................... Aac RMS See Table NOMINAL INPUT VOLTAGE ................................................... User selects 220Vac to 440Vac LOAD VOLTAGE RANGE ....................................................... 220Vac Nominal 160 to 300Vac 440Vac Nominal 320 to 480Vac FREQUENCY............................................................................ 57 TO 63Hz BURDEN ................................................................................... 1VA typical POWER FACTOR RANGE ...................................................... 1 to zero (lead or lag)
TERMINAL IDENTIFICATION 1. LOAD POTENTIAL (HI) (440Vac OPERATION ONLY) 2. LOAD POTENTIAL (HI) (220Vac OPERATION ONLY) 3. LOAD POTENTIAL (LO) (220 OR 440Vac OPERATION) 4. OUTPUT (RTN) 5. OUTPUT (+) 6. CASE GROUND
OUTPUT VOLTAGE SIGNAL .................................................................. ACCURACY.............................................................................. RESPONSE............................................................................... RIPPLE (PEAK) ........................................................................ P.F. PHASE ANGLE ERROR .................................................. TEMPERATURE COEFFICIENT ............................................. OUTPUT IMPEDANCE.............................................................
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.................................. 0° to +50°C STORAGE TEMPERATURE RANGE ..................................... -40° to +85°C
AAC Code Ident. No. 15948
0 to +5VdcFS (Full Scale) ±2% FS (±100mV) 400m-sec max. 3% FS max. ±3°,max. ±0.2% FS/°C 2.5K-Ohms max.
Drawing Number
Rev.
700700- S217S217- 413
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
FREQUENCY TRANSDUCER SERIES S350L PART NO.
RANGE (Hz F.S.)
S350L-100................... 100 S350L-200................... 200 S350L-300................... 300 S350L-500................... 500 S350L-1K .................... 1K
PART NO.
RANGE (Hz F.S.)
S350L-2K ................................. 2K S350L-3K ................................ 3K S350L-5K ................................ 5K S350L-10K .............................. 10K S350L-20K ............................... 20K
AC INPUT FREQUENCY RANGES................................................... See Table SENSITIVITY, MINIMUM.................................................. 20mV RMS 5% to 100% F.S. (sine or sq. wave) SENSITIVITY, MAXIMUM................................................. There shall be no signal output for an input signal of 5mV RMS or less over the frequency range of D.C. to 20KHz PULSE WIDTH ................................................................. Minimum duration must equal 20% of the period of the maximum full scale input frequency. IMPEDANCE..................................................................... 5000 Ohms minimum VOLTAGE RANGE........................................................... The max. allowable input voltage is a function of input freq. and is equal to the input freq. divided by 2 (up to a max. of 50V RMS). INPUT ............................................................................... Transformer coupled may be connected either differentially or signal ended. COMMON MODE REJECTION ....................................... 60dB @ 60Hz with input connected differential. OUTPUT VOLTAGE SIGNAL........................................................... LINEARITY........................................................................ OUTPUT IMPEDANCE .................................................... RIPPLE .............................................................................
0 to 5Vdc F.S. with 5mA max. current ±0.1% of FS freq. @ 26Vdc power 1 Ohm max. <0.1% pk @ F.S. output increasing to approximately 1% pk-pk 1/10 F.S. input freq. ADJUSTMENT.................................................................. A trimpoint adjusts the gains such that a 5Vdc .......................................................................................... max. output may be established for freq. Input ½ F.S. min. LONG TERM STABILITY ................................................. ±0.2% F.S. per year RESPONSE ...................................................................... 30/F where F is the max. F.S. freq. To 63% TEMPERATURE COEFFICIENT ..................................... ±0.01%/°C of F.S. freq.
POWER SUPPLY SUPPLY VOLTAGE ......................................................... +22 to 30Vdc @ 120mA max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE........................................ -48°C to +74°C STORAGE TEMPERATURE ........................................... -55°C to +85°C ISOLATION....................................................................... Input/Output/Power/Case INSULATION RESISTANCE............................................ 100M-Ohms @ 500Vdc VIBRATION....................................................................... 6g RMS 20Hz to 2KHz ALTITUDE......................................................................... Sea Level to 80,000 ft. WEIGHT ........................................................................... 3 lbs. Max. FINISH .............................................................................. Orange paint per FED-STD-595 No. 12197 or equiv.
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S350L
D
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
FREQUENCY TRANSDUCER SERIES S343
PART NO. S343-120 S343-220
VOLTAGE RANGE 102 to 127 Vac 200 to 250 Vac
OVERLOAD
BURDEN
140 Vac max. 280 Vac max.
1.5 VA @ 120V 1.5VA @ 220V
OUTPUT VOLTAGE SIGNAL................................................................................ ACCURACY........................................................................................... RIPPLE AND NOISE (BROADBAND) .................................................. RESPONSE (0 to 99%) ......................................................................... TEMPERATURE ERROR .....................................................................
0Vdc @ 360Hz to 5Vdc @ 440Hz ±1.0% FS (±.05V) 25mV RMS; 50mV peak max. 250mS max. ±1Hz max. (-20°C to 70°C) ±1.3Hz max. (-40°C to 70°C) IMPEDANCE.......................................................................................... 100 Ohms max. RANGE ADJUSTMENT ........................................................................ ±3% F max. (±150mV) ZERO ADJUSTMENT ........................................................................... ±3% F max. (±150mV)
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE............................................... STORAGE TEMPERATURE RANGE .................................................. VIBRATION............................................................................................ ALTITUDE.............................................................................................. DIELECTRIC STRENGTH @ SEA LEVEL........................................... INPUT/OUTPUT ISOLATION ............................................................... WEIGHT ................................................................................................ FINISH HOUSING ................................................................................. IDENTIFICATION ..................................................................................
-40°C to +70°C -55°C to +85°C 6g RMS, 20Hz to 2KHz -1000 ft. to 60,000 ft. 1200Vac, 400Hz (all pins to case except case ground pin) 50M-Ohms @ 50Vdc 28 oz. max. Orange paint per FED-STD-595 Number 12197 or equivalent. Each unit shall be identified with MFR’s P/N, MFR’s S/N and GAC P/N 90SCAE28401-*
AAC P/N
GAC P/N
S343-120
90SCAE28401-1
TERMINAL IDENTIFICATION A. AC INPUT B. AC INPUT (RTN) C. CASE GROUND D. OUTPUT SIGNAL (+) E. OUTPUT SIGNAL (RTN) F. SPARE
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-S343
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ± .010
DC CURRENT SENSOR SERIES 904B PART NO.
CURRENT RANGE
904B-L01 ....................0 TO 100uA 904B-L02 ....................0 TO 200uA 904B-L05 .................... 0 TO 500uA
PART NO.
CURRENT RANGE
904B-L1 .................................. 0 TO 1mA 904B-L2 ................................. 0 TO 2mA 904B-L5 ................................. 0 TO 5Ma
INPUT CURRENT RANGES ....................................................... See Table INPUT RESISTANCE ...................................................... 10 Ohms max. ISOLATION (Input to Output) .......................................... 500Vdc max. OUTPUT VOLTAGE SIGNAL.......................................................... 0 to +5.0Vdc FS (Full Scale) ACCURACY..................................................................... ±1% FS RIPPLE............................................................................ 2% FS RMS IMPEDANCE ................................................................... 1000 Ohms ±5% RESPONSE (10 to 90%) ................................................. 50 m-sec. max. TEMPERATURE COEFFICIENT..................................... ±0.04% FS/°C POWER SUPPLY SUPPLY VOLTAGE ........................................................ +28Vdc ±4Vdc CURRENT DRAIN ........................................................... 50mAdc max. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.......................... -55°C to +85°C STORAGE TEMPERATURE RANGE ............................. -60°C to +100°C INSULATION RESISTANCE ........................................... 100 M-ohms (all terminals to case) DIELECTRIC STRENGTH............................................... 350V RMS (all terminals to case) ALTITUDE ....................................................................... Operating sea level to 60,000 ft. VIBRATION ..................................................................... Operating - 0.06 in. D.A., 10 to 55 Hz method 201 of MIL-STD-202 SHOCK ............................................................................ Operating 50 g, 11 m-sec half sine pulse method 213 Condition A of MIL-STD-202 MOISTURE RESISTANCE.............................................. Will meet method 106 of MIL-STD-202 and method 507.1 Proc. 1 of MIL-STD-810 OPERATING HUMIDITY ................................................. 0% to 95% RH ATTITUDE ....................................................................... Meets spec. for any mounting position WEIGHT .......................................................................... 1.25 lbs. Max.
TERMINAL IDENTIFICATION A. B. C. D. E. F.
SUPPLY VOLTAGE (+) SUPPLY AND OUTPUT (RTN) OUTPUT SIGNAL (+) CURRENT INPUT (+) CURRENT (RTN) CASE GROUND
AAC Code Ident. No. 15948
Drawing Number
Rev.
700-904B
G
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(631) 694-5100 Fax:(631) 694-6739
Dimensions in Inches, Tolerances: .XX ± .03
.XXX ±
A.C.CURRENT SENSOR SERIES 1003AM2-B OUTPUT INPUT CURRENT IMPEDANCE MODEL NO. 1003AM2-10-B ....................... 0 to 10Aac......................................................... 7 1003AM2-15-B ....................... 0 to 15Aac......................................................... 5 1003AM2-20-B ....................... 0 to 20Aac...................................................... 3.5 1003AM2-25-B ....................... 0 to 25Aac...................................................... 3.0 1003AM2-30-B ....................... 0 to 30Aac...................................................... 2.5 1003AM2-50-B ....................... 0 to 50Aac...................................................... 1.5 1003AM2-75-B ....................... 0 to 75Aac...................................................... 1.0 1003AM2-100-B ..................... 0 to 100Aac.................................................... 0.7 1003AM2-125-B ..................... 0 to 125Aac.................................................... 0.6 1003AM2-150-B ..................... 0 to 150Aac.................................................... 0.5 1003AM2-200-B ..................... 0 to 200Aac.................................................... 0.4 1003AM2-250-B ..................... 0 to 250Aac.................................................... 0.3 1003AM2-300-B ..................... 0 to 300Aac.................................................. 0.25 INPUT CURRENT RANGE ............................................................................. See Table FREQUENCY ...................................................................................... 57 to 63Hz OVERLOAD......................................................................................... 500Aac Continuous OUTPUT VOLTAGE SIGNAL.............................................................................. ACCURACY......................................................................................... RIPPLE................................................................................................ IMPEDANCE ....................................................................................... REPEATABILITY................................................................................. RESPONSE......................................................................................... TEMPERATURE COEFFICIENT......................................................... OUTPUT SIGNAL @ OVERLOAD .....................................................
0 to 5Vdc FS (Full Scale) ± 1% FS 3% FS RMS K Ohms See Table 0.5% FS 150 m-sec ± 0.04% FS/ °C 11Vdc max.
POWER SUPPLY SUPPLY VOLTAGE............................................................................. None, self excited ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS OPERATING TEMPERATURE RANGE.............................................. STORAGE TEMPERATURE RANGE ................................................. ISOLATION.......................................................................................... INSULATION RESISTANCE ............................................................... WEIGHT ..............................................................................................
TERMINAL IDENTIFICATION 1. OUTPUT SIGNAL (+) 2. OUTPUT SIGNAL (RTN)
Code Ident. No. 15948
- 20° C to 70°C - 55°C to 85°C Input/Output/Case 100 M-Ohms 1.25 lbs. max.
MOLDED TERMINAL BLOCK WITH 5-40 TERMINAL SCREWS 3/8 IN. CENTER TO CENTER SPACING. ACCEPTS WIRE SIZES UP TO 14 AWG & WIRE LUGS UP TO 9/32 IN. WIDE.
AAC
Drawing Number
Rev.
700-1003AM2-B
E
AAC American Aerospace Controls Inc., 570 Smith Street, Farmingdale, New York 11735 Tel:(516) 694-5100 Fax:(516) 694-6739