FLOW Product Data Sheet
DS1720
DP & Flow Transmitter MICRO-BAR DIFFERENTIAL PRESSURE/FLOW TRANSMITTER Micro-Bar electronic transmitter incorporates a capacitance based differential pressure cell for sensitive measurement on Air or other dry gases. Designed for gas flow measurement applications on extraction or ventilation systems, the micro based electronics uses calibration formulae required for FloBar Averaging Pitot tubes, Orifice Plates or other standard DP based sensors. Simply installed adjacent to the flow line, standard pressure impulse tubing links the sensor directly to the Micro-Bar unit. Flow rate,flow units and alarm status are displayed on the two line LCD: external signal transmission is via the 4-20mA loop power,with separate alarm relay and totaliser pulse.
FEATURES •
DP measurement for gases
•
High sensitivity and linearisation for Pitot tube flow measurement
•
Digital flowrate display in Engineering units
•
±0.5% accuracy
•
Flow totaliser pulse output
•
High and low flow alarms
•
Site programmable outputs
With simple adjustment over a 5:1 full scale pressure range available to the operator on site, the Micro-Bar suits varying process conditions or output scaling requirements. The micro based electronics simplifies site setup procedures, allowing adjustment of alarm output set points, totalisation pulse rate, averaging time and zero checking. Micro-Bar is applicable to measuring pressure differentials on operating theatres, clean rooms or glove boxes, to monitor system performance and provide alarms. On process monitoring, Micro-Bar is used for air filter blockage monitoring and burner control on furnaces. For these duties, the display shows the pressure drop directly.
Display & 4mm Push-in Fitting Shown
DS1720
Page 1 of 2
130
MICRO-BAR APPLICATIONS
DIMENSIONS 15
FLOW MEASUREMENT Pressure ports are connected to a Platon Flobar Averaging Pitot tube or orifice plate via 4mm OD nylon impulse pipes. Using the calibration sheet supplied with the Flo-Bar, the Micro-Bar full scale pressure is ranged to the appropriate value for site conditions. Units are selected from the look up table and the square root extraction mode used to give using the Micro-Bar press buttons. Remote transmission is via the 4-20mA loop, wired via a recorder and display to a DC power source.
12
Height 115 3
H 120.4m /S Mode 1: SQRT
185
FLOW TOTALISATION Separate flow totalisation with an external counter/display or a pulse totaliser can be achieved from the second relay output in the Micro-Bar.
Transparent Hinged Lid
MICRO-BAR 55
DP ALARM
Height 70
Simple impulse tube pressure connections can be made to the Micro-Bar unit to monitor DP across a filter, to detect blockage, or to a pressurised clean room, to monitor the maintenance of the required DP and alarm on hazardous conditions. Micro-Bar units provide the analogue output for recording purposes and the alarm output to signal the potential hazard: two separate alarm levels are available.
MOUNTING HOLES 15
SPECIFICATION Media Range (max DP)
See Coding Breakdown For Details
Output 20mA Adjustment Zero DP Setting Output vs DP Display Power Supply Averaging Accuracy@20mA Temperature Range Long Term Drift Static Pressure Max Pressure Connections Alarm Outputs
Flow Totaliser
Enclosure Electrical Connections
Hi
Lo
145 Air or dry non-corrosive gases 0-30 Pa (0-0.1” wg) 0-100 Pa (0-0.4” wg) 0-150 Pa (0-0.6” wg) 0-300 Pa (0-1.2” wg) 0-1000 Pa (0-4” wg) 0-3000 Pa (0-12” wg) 0-10 kPa (0-40” wg) 0-30 kPa (0-120” wg) 0-1 bar (0-400” wg) 4-20mA 20% to 100% of max DP Adjustable 0-100% of max DP range Selectable linear or square root 2 line, 16 x 5mm high digits showing flow/pressure, units and alarm status 10-50vdc loop powered 0-60 seconds adjustable ±0.5% of max DP range ±0.75% of reading 0-40ºC 0.5% per year 5 times max DP range Pushfit sockets for 4mm OD tubing or 1/4” NPT Female 2 x volt free relay contacts Selectable NO/NC Max 1 Amp rating 110V ac/dc One alarm relay optionally selectable as totaliser. Max pulse rate 100 pulse/minute. Pulse length 50msec Polyester. IP66 with separate terminal compartment 2 x M20 glands
10 116 CONNECTIONS SK1
SK2
C NO/NC C NO/NC
Range (Pascals) MB1a = 0-150 MB0 = 0-30 MB1 = 0-100 MB2 = 0-300 MB3 = 0-1000 MB4 = 0-3000 MB5 = 0-10000 MB6 = 0-30000 MB7 = 0-1 bar
+
4-20mA Loop (to DC Power Supply)
1
Alarm Output (Operator Adjustable) Selectable as Either Totaliser Pulse or Second Alarm
2
MB1 - BL - NO - ST
Type of Display BL = Blind System/4-20mA Output DR = Display Rate of Flow/420mA Output DT = Display Rate of Flow/Totalised Display/4-20mA Output
Connections ST = 4mm O/D Tube Push-in Connector CF = 1/4” NPT Female
Electrical Output NO = No Alarm Output 01 = 2 Relay Alarm or Totaliser Outputs (User Selectable) 110Vac @ 1Amp 02 = 2 Relay Alarm or Totaliser Outputs (User Selectable) 30Vac @ 3 Amps
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
03HWAR0510
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838 email: sales@roxspur.com www.roxspur.com
DS1720
Page 2 of 2
FLOW An
Brand
Product Data Sheet
DS2602
DIFFERENTIAL PRESSURE GAUGES MAGNEHELIC DIFFERENTIAL PRESSURE GAUGES The Magnehelic® is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves and monitors blood and respiratory pressures in medical care equipment. Note: Do not use with Hydrogen gas.
PRESSURE RANGES SPECIFICATION Ranges
Pascals, mm or inch WG, pitot flow Media Air & non corrosive gases Accuracy ±2% FSD Rated Pressure -20”Hg to15psig (-68 kPa to 103 kPa) Ambient Temperature -7 to 60°C Connections 1/8" NPT female. high and low pressure taps duplicated - one pair at side and one pair at back of gauge. Plugs and adaptors for 5mm ID tube supplied Housing Die cast aluminium iridite dipped Diaphragm Silicon rubber, overpressure protected Zero Adjust Screw Mounted in meter face Over Pressure Relief plug opens at approximately 25 psig (172 kPa) Weight 0.46kg
Inches Water 0-1 0-2 0-4 0-5 0-10 0-15 0-20 0-50
Model
Pascals
Model
M2001 M2002 M2004 M2005 M2010 M2015 M2020 M2050
0-60 0-100 0-125 0-250 0-500 0-750 0-1K 0-1.5K 0-2K 0-5K
M2000-60Pa M2000-100Pa M2000-125Pa M2000-250Pa M2000-500Pa M2000-750Pa M2000-1Kpa M2000-1.5Kpa M2000-2Kpa M2000-5Kpa
mm Water 0-50 0-100 0-250 0-50cm
Model
Centre zero (Pa) 30-0-30 60-0-60 125-0-125
Model
M2000-50mm M2000-100mm M2000-250mm M2000-50cm
M2300-60Pa M2300-120Pa M2300-250Pa
Other models are available with Flow units scaled for Pitots or Orifice Plates.
DS2602
Issue 1: 27.09.02
Page 1 of 2
Construction Features Bezel provides flangefor flush mounting in panel
O-ring seal for cover assures pressure integrity of case
Clear plastic face is highly resistant to breakage. Provides undistorted view of pointer and scale.
Blowout plug of silicone rubber protects against overpressure on 15 psig (1 barg) rated models. Opens at approximately 25 psig (1.7 barg).
Precision litho-printed scale is accurate and easy to read.
Die cast aluminium case is prcision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark grey hammeroid. One case size is used for all standard pressure options and for both surface and flush mounting.
Red tipped pointer of heat treated aluminium tubing is easy to see. It is rigidly mounted on the helix shaft.
Silicon rubber diaphragm with integrally moulded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
Pointer stops of moulded rubber prevent pointer over-travel without damage. “Wishbone� assembly provides mounting for helix, helix bearing and pointer shaft.
Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reactsto pressure on diaphragm. Live length adjustable for calibration.
Jeweled bearings are shock-resistant mounted; providevirtually friction-free motion for helix. Motion damped with high viscosity silic one fluid. Zero adjustment screw is conveniently located in th eplastic cover and is accessible without removing cover.
Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkage.
Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely following the magnetic field to move the pointer across the scale.
DIMENSIONS
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
0043
DS2602
1 - 4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
Issue 1: 27.09.02
CERTIFICATE NO. 22358
Page 2 of 2
FLOW An
Brand
Product Data Sheet
DS2604
DP Gauge with Alarms PHOTOHELIC ® DIFFERENTIAL PRESSURE GAUGES WITH ALARMS
SPECIFICATION DP Ranges Accuracy Media Housing
Using solid state technology, the Series 3000MR Photohelic® switch/gauges combine the functions of a precise highly repeatable differential pressure switch with a large easy-to-read analogue pressure gauge employing the durable timeproven Magnehelic® design. Switch setting is easy to adjust with large external knobs on the gauge face. Gauge reading is unaffected by switch operation, it will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4 13/16" (122 mm) hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts that are ideal for dry circuits. All models provide both low and high limit control and include 18-inch (45 cm) cable assemblies for electrical connections. Gauge accuracy is ±2%of full scale and switch repeatability is ±1%. Switch deadband is one pointer width; less than 1% of full scale. Compatible with air and other non-combustible non-corrosive gases they can be used in systems with pressures to 25 psig (1.725 bar). Optional construction is available for use to either 35 psig (2.42 bar) or 80 psig (5.51 bar).
DS2604
Pascals (See order codes) ±2% FSD Air & non corrosive gases Die cast aluminium Baked dark gray epoxy hammerloid. Process Connections 1/8" NPT female (rear & side) Max Pressure 25 psig Temperature -5 to 50°C Power Supply 24VDC Output 2 x SPCO relays, 1 Amp @ 30VDC 0.5 Amp at 125VAC Electrical Connection 450mm 8 core cable Panel Cut Out 123mm dia Overall Size 140 dia. x 65mm deep Weight 0.75Kg
PRESSURE RANGES Model 3000-0MR 3001MR 3002MR 3003MR 3005MR 3010MR 3015MR 3020MR 3030MR 3050MR 3100MR
Inches W.C. 0-0.5 0-1.0 0-2.0 0-3.0 0-5.0 0-10 0-15 0-20 0-30 0-50 0-100
Minor Divs. .01 .02 .05 .10 .10 .20 .50 .50 1.0 1.0 2.0
Model 3000MR-60Pa 3000MR-125Pa 3000MR-250Pa 3000MR-500Pa
Pascals 0-60 0-125 0-250 0-500
Minor Divs. 2.0 5.0 5.0 10.0
Model 3000MR-1kPa 3000MR-3kPa 3000MR-4kPa
Kilopascals 0-1.0 0-3.0 0-4.0
Minor Divs. .02 .10 .10
Model 3000MR-6MM 3000MR-10MM 3000MR-25MM 3000MR-50MM 3000MR-100MM
MM W.C. 0-6 0-10 0-25 0-50 0-100
Minor Divs. .20 .50 .50 1.0 2.0
Model 3000MR-20CM
CM W.C. 0-20
Minor Divs .50
Issue 1: 10.10.02
Page 1 of 2
CONSTRUCTION FEATURES Bezel provides flangefor flush mounting in panel
O-ring seal for cover assures pressure integrity of case
Clear plastic face is highly resistant to breakage. Provides undistorted view of pointer and scale.
Blowout plug of silicone rubber protects against overpressure on 15 psig (1 barg) rated models. Opens at approximately 25 psig (1.7 barg).
Precision litho-printed scale is accurate and easy to read.
Die cast aluminium case is prcision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark grey hammeroid. One case size is used for all standard pressure options and for both surface and flush mounting.
Red tipped pointer of heat treated aluminium tubing is easy to see. It is rigidly mounted on the helix shaft.
Silicon rubber diaphragm with integrally moulded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
Pointer stops of moulded rubber prevent pointer over-travel without damage. “Wishbone� assembly provides mounting for helix, helix bearing and pointer shaft.
Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reactsto pressure on diaphragm. Live length adjustable for calibration.
Jeweled bearings are shock-resistant mounted; providevirtually friction-free motion for helix. Motion damped with high viscosity silic one fluid. Zero adjustment screw is conveniently located in th eplastic cover and is accessible without removing cover.
Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkage.
Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely following the magnetic field to move the pointer across the scale.
DIMENSIONS
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
0043
DS2604
1 - 4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
Issue 1: 10.10.02
CERTIFICATE NO. 22358
Page 2 of 2
FLOW An
Product Data Sheet
Brand
DS2605
DP Gauge with Transmitter MAGNEHELIC GAUGES WITH TRANSMITTER
SPECIFICATION
The 605 Series Magnehelic ® Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure. The Series 605 is ideal for control applications in building HVAC systems where local indication is desired during routine maintenance checks or necessary when trouble shooting the system. The easily read dial gauge is complemented by the two-wire, 4-20 mA control signal utilising the time-proven Magnehelic® gauge mechanical design and Series 600 straingauge transmitter technology. The two-wire design with terminal strip on the rear simplifies connection in any 4-20 mA control loop powered by a 12.3-35 VDC supply.
DP Ranges Accuracy Power Supply: Output Signal:
PRESSURE RANGES Model
Inches w.c
Maximum Pressure
605-00N 605-11 605-0 605-1 605-2 605-3 605-6 605-10 605-20 605-30 605-50
.05-0-.20 .25-0-.25 0-.50 0-1.0 0-2.0 0-3.0 0-6.0 0-10 0-20.0 0-30 0-50 Pa 0-250 0-500
1.7 bar 1.7 bar 1.7 bar 2.5 kPa 34.5 kPa 34.5 kPa 1.4 bar 1.4 bar 1.4 bar 1.4 bar
605-250 Pa 605-500 Pa
1.7 bar 2.5 kPa
Electrical Accuracy +/- % 2 2 2 0.5 0.5 0.5 0.5 0.5 0.5
Mechanical Accuracy +/-% 4 3 2 2 2 2 2 2 2
2 0.5
2 2
Pascals or inch WG ±2% FSD 10 to 35 VDC 4 to 20 mA DC, 2 wire (limited at 38 mA max.) Loop Resistance: 0-1250 ohms from 10 to 35 VDC Current Consumption: 38 mA DC (max.) Material: Die cast aluminum case, baked dark gray hammerloid finish, acrylic cover. Span and Zero adjustments: Protected potentiometers Media Air and non corrosive gases Connections 1/8" NPT female Pressure 25 psig max Temperature 0-50°C Panel Cut Out 123mm dia Overall Size 140 dia. x 65mm deep Weight 1.14Kg PERFORMANCE AT 70°F Zero output: 4 mA Full span output: 20 mA Stability: ±1% F.S.O. /yr Warm-up time: 10 minutes Thermal Error: ±1%/50°F typical (-1 to 49°C).
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
0043
DS2605
1 - 4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
CERTIFICATE NO. 22358
Issue 1: 10.10.02
Page 1 of 1
An
PRESSURE
Brand
Product Data Sheet
DS2701
M6420-92 Flush Mounted Transmitter The M6420-92 is ideal for applications where the sensing element has to be in direct contact with the media. This enables measurement of medias that contain particles or are liable to congeal.
DESCRIPTION The M6420-92 pressure transmitter is based on a four active arm strain gauge bridge fused to a high purity ceramic diaphragm, offering high natural output coupled with superb chemical and corrosion resistance. It has a two wire, 4-20mA output proportional to pressure and is fully CE compliant. The sensing element and its associated electronics are housed in a rugged stainless steel case. It has a M24 x 2 threaded pressure fitting and a flush mounted sensor, sealed via an O-ring.
SPECIFICATION Pressure Ranges Excitation Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Safe Over-range Burst Pressure
Pressure Connection Insulation Resistance Load Driving Environmental
Long Term Stability Wetted Materials
FEATURES
EMC Protection ● ● ● ● ● ● ● ●
1, 2, 3, 5, 10, 20 & 50 bar gauge or absolute. Other ranges available 10-32Vdc unregulated 16mA ±1% 4mA ±1% of span <±0.25% span (best fit straight line) -10oC to 80oC -25oC to 120oC <±0.015% span / oC <±0.015% reading / oC 1.5 x rated range minimum 3 x rated range minimum For 50 bar transmitter, burst pressure 2 x rated range M24 x 2 >500M Ω at 500Vdc, over the operable temperature range 1k Ω @ 28Vdc supply IP68 with submersible cable which has a strain wire and a vent tube for gauge format sensors 0.1% / 12 months typical 316L stainless steel, alumina ceramic PUR cable, ESP109 epoxy resin IEC 801 parts 2, 3 & 4
Superb chemical and corrosion resistance 4-20mA, two wire output Excellent linearity Wide temperature range High electrical isolation Rugged construction Excellent long term stability Temperature compensated
APPLICATIONS ● ● ● ● ● ● ● ● ●
Water level/pressure Data logging Chemical processing Soil mechanics Load measurement Automotive Printing, Medical engineering Air compressors
DS2701
● ● ● ● ● ● ● ●
Gas flow Pneumatic controls Central heating Hydraulic machinery Air conditioning Tank contents Crop spraying Paper processing
Issue 3: 12.01.06
Page 1 of 2
DIMENSIONS
Ø27
4 Core Cable with Vent Tube & Strain Wire Cable Gland IP68 to 10 bar 316L Stainless Steel Ø25
Cover 316L Stainless Steel Ø27
TIG Weld 84
Case 316L Stainless Steel Ø27
27 A/F Hex
M24 x 2 (Male thread)
Ceramic sensor front face, flush with end of pressure port
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2701
Issue 3: 12.01.06
Page 2 of 2
PRESSURE Product Data Sheet The FCX-CII pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20mA signal. The transmitter utilizes the unique micromachined capacitive silicon sensor with state-ofthe-art microprocessor technology to provide exceptional performance and functionality.
DS2710
Gauge Pressure Transmitter
FEATURES 1- High accuracy 0.1% accuracy for all calibrated spans is the standard feature covering 81,25mbar to 100bar. Fuji’s micro-capacitance silicon sensor assures this feature for all elevated or suppressed calibration ranges without additional adjustment. 2- Minimum inventory Electronics unit, local indicatiors and electronics housing are interchangeable among all FCX-CII models. 3- Fuji/HART® bilingual communication protocol and FOUNDATION FIELDBUS and PROFIBUS compatibility. FCX-CII series transmitter offers bilingual communication to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX-CII. Further, by upgrading electronics Foundation Fieldbus and Profibus is also available. 4- Application flexibility Example features that render the FCX-CII suitable for almost any process applications includes : - Analog indicator at either the electronics side or terminal side - Full range of hazardous location approvals - Built-in RFI filter and lightning arrester - 5 digits LCD meter 5- Programmable output Linearisation Function In addition to linear and square root, output signal can be freely programmable. 6- Burnout current flexibility (Under Scale: 3,2 to 3,8mA, Over scale: 20,8 to 21,6mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 7- Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.
SPECIFICATIONS Functional specifications Type : FKP : Smart, 4-20mA DC + Fuji/Hart® digital signal FDP : Fieldbus Foundation & Profibus Service : Liquid, gas or vapour Span, range and overrange limit : Type F F F F
P P P P
01 02 03 04
Span Limit (bar) Min. Max. 0.08125 1.3 0.3125 5 1.875 30 6.25 100
Range Limit -1 -1 -1 -1
to +1.3 to +5 to +30 to +100
Overrange Limit (bar) 10 15 90 150
- Lower range limit (vacuum limit) is : Silicone fill sensor : See Fig. 1 Fluorinated fill sensor : 66kPa abs (500mmHg abs) at below 80°C - Conversion factors to different units : 1MPa=10 3 KPa=10bar=10.19716kgf/cm 2 = 145.0377psi 1KPa=10mbar=101.9716mmH 2 O =4.01463inH 2 O Output signal : 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal.
Digital signal based on Foundation Fieldbus or Profibus Power supply : Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester.
DS2710
Issue 1: 26.07.02
Page
1 of 7
Load limitations: see figure below
(-10 to +60°C for fluorinated oil fill transmitter) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process : -40 to +100°C for silicone fill sensor -20 to +80°C for fluorinated oil fill sensor Storage : -40 to +90°C Humidity limit : 0 to 100% RH Communication : With HHC (Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely dis-played or reconfigured. Note : HHC's version must be higher than 6.0 (or FXW 1-A3)
Note : For communication with FXW, min. of 250 . required.
Hazardous locations : Designed to meet international intrinsic safety and flameproof (explosionproof) standards. Please consult the code symbols some pages further on, to know the different types of approvals (digit 10). Consult FUJI for status. Zero/span adjustment : Zero and span are adjustable from the communicator HHC. Zero is also adjustable externally from the adjustable screw. Damping : adjustable electrical damping. The time constant is adjustable between 0 to 38.4 seconds with the communicator HHC. Zero elevation/suppression : Selectable with the communicator HHC Normal/reverse action : Selectable by moving a jumper pin located on the electronics unit. Indication : Analog indicator or 5 digit LCD meter, as specified. Burnout direction: Selected from HHC If self-diagnostic detect transmitter failure, the analog signal will be driven to eighter "Output Hold", "Output Overscale" or "Output Underscale" modes. "Output Hold" : Output signal is hold as the value just before failure happens. "Output Overscale" : approx. 21,6 mA Adjustable within the range 20,8 mA to 21,6 mA from the HHC "Output Underscale" : approx. 3,8 mA Adjustable within the range 3,2 mA to 3,8 mA from the communicator HHC.
Programmable output linearization function : Output signal can be characterized with "14 points linear approximation function" from HHC. Field Bus units : Digital signal Transmission technique : according to IEC61158-2 Power supply : 9VDC...32VDC Base current : 15 ±2mA Transmission rate : 31,25kbits/s Profibus-PA : version 3.0, DPVI version 2.0 Foundation Fielbus : FF-890/891
Loop-check output : Transmitter can be configured to provide by HHC constant signal output between 3.8mA and 21.6mA. Temperature limit : Ambient : -40 to +85°C (-20 to +80°C for LCD indicator) (-40 to +60°C for arrester option)
DS2710
Issue 1: 26.07.02
Page
2 of 7
Performance specifications
Physical specifications
Accuracy rating : (including linearity, hysteresis, and repeatability) For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: ± (0.05 + 0.05 0.1 x URL ) % of span span
Electrical connections : 1/2"-14 NPTE, Pg13.5 or M20 x 1.5 Process connections : 1/2"-14NPTI, 1/2"-14NPTE, 1/4"-18NPTI, Rc 1/2", G1/2" A manometer fitting. Process-wetted parts material :
Stability : ±0.2% of upper range limit (URL) for 24 months Temperature effect : Effects per 28°C change between the limits of 40°C and +85°C: Zero shift : ±0.25%/28°C at (1 to 1/2.5) x URL ± (0.25 0.4 x URL) %/28°C span
For spans below 1/2.5 of URL Total effect : ±0.5%/28°C at (1 to 1/2.5) x URL ± (0.25+0.25 0.4 x URL)%/28°C span
For spans below 1/2.5 of URL Overrange effect : Zero shift, 0.3% of URL for any overrange to maximum limit Supply voltage effect : Less than 0.05% fo calibrated span per 10V RFI effect : Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. (Classification: 2-abc: 0.2% span per SAMA PMC 33.1) Step response : (without electrical damping) Time constant : 0.2s Dead time : about 0.3s Time constant ( ) = 63 % output signal Response time = 5 x time constant + dead time Mounting position effect : Zero shift, less than 0.1kPa {1mbar} for a 10° tilt in any plane. No effect on span. This error can be corrected by ad-justing zero. (Double the effect for fluorinated fill sensors) Dielectric strength : 500V AC, 50/60Hz 1 min., between circuit and earth Insulation resistance : More than 100M . at 500V DC Turn-on time : 4 sec. Internal resistance for external field indicator : 12 Ω or less
DS2710
Issue 1: 26.07.02
Non-wetted parts material : Electronics housing : Low copper die cast aluminum alloy (standard), finished with epoxy/polyurethane double coating, as specified. Fill fluid : Silicone oil (standard) or fluorinated oil Mounting bracket : 304 stainless steel Environmental protection : IEC IP67 and NEMA 6/6P Mounting : On 50mm (2") pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass {weight} : Transmitter approximately 1.9kg without options. Add : 0.5kg for mounting bracket 0.8kg for indicator (option)
Page
3 of 7
Optional features Indicator : A plug-in turnable analog indicator (1.5% accuracy) can be located in the electronics compartment or in the terminal box of the housing. An optional 5 digits LCD meter is also available. Arrester : A built-in arrester protects the electronics from lightning surges. Lightning surge immunity : 4KV (1.2 x 50Âľs) Oxygen service : Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Degreasing : Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use for oxygen or chlorine measurement. NACE specification : Metallic materials for all pressure boundary parts comply with NACE MR-01-75. Vacuum service : Special silicone oil and filling procedure are applied. See figure 1 below
ACCESSORIES Hand-held communicator : Model FXW, refer to Data Sheet No. EDS8-47) Two valve Manifold : Available in 316 stainless steel and pressure rating 10MPa (100bar).
Fig.1 Relation between process temperature and operating pressure
Customer tag : A stainless steel tag with customer tag data is wired to the transmitter.
DS2710
Issue 1: 26.07.02
Page
4 of 7
DS2710
Issue 1: 26.07.02
Page
5 of 7
DS2710
Issue 1: 26.07.02
Page
6 of 7
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
10 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspurmc.co.uk www.controlsdirect.com
DS2710
Issue 1: 26.07.02
Page
7 of 7
PRESSURE Product Data Sheet
DS2801
Sensit Trident Series Submersible Level/DepthTransmitter The Sensit Trident Series Level/Depth Transmitter is a temperature compensated pressure transmitter designed for the measurement of liquid level in many applications, such as pump testing, reservoir, borehole, river and tank levels. The unit is of welded construction and is ideal for even the most onerous of applications. ● ● ● ●
● ● ●
Lightning protection as standard Superb chemical and corrosion resistance Excellent linearity Wide operational & compensated temperature range Rugged construction Excellent long term stability CE Compliant
SPECIFICATION Pressure Ranges
Power Supply Output Zero and Span Setting Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Operating Temp Thermal Effects Zero: Span: Safe Over-range Burst Pressure Long Term Stability EMC Protection Electrical Connection Wetted Materials
Available from 1mWG to 500mWG vented. Absolute available from 2.5mWG 10 to 32Vdc 4 to 20mA (two wire) +1% of span <+0.25% of span 0oC to 60oC -10oC to 60oC <+0.015% span/oC <+0.015% reading/oC typical 1.5 x rated range minimum 3 x rated range minimum 0.1% span/12 months Meets EN2004/108/EC PUR vented cable 316L stainless steel, alumina ceramic, polyurethane, acetal and Viton O-ring
OPTIONS ● ● ● ●
● ● ●
DS2801
Materials: duplex stainless steel O-ring materials: nitrile, others available Output: active mV/voltage Calibrated ranges: bar, psi or liquid depth (SG to be specified) NL&H : <±0.1% of span Intrinsically safe to EEx ia IIC T4 (mA only) Cost effective stainless steel gland
Page 1 of 2
DIMENSIONS (mm)
78
Moulded Material Polyurethane
4 Core Cable with Vent Tube & Strain Wire
CASE & COVER MATERIALS 316L ST ST (Duplex Steel also available)
LABEL Tig Welds
Hex 18A/F
Pressure Port G1/4 (BSP) Ă&#x2DC; 25
Submersible transducers and transmitters must be installed to the RM&C recommended method, please contact the Bramley sales office (on +44 (0)1256 884 900) for details. Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
04HWAR0211
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2801
Page 2 of 2
PRESSURE Product Data Sheet
DS2803
Sensit P6420-26 Field Re-Rangeable Transmitter The Sensit P6420-26 is a high performance, temperature compensated pressure transmitter having a two wire, 4-20mA output, with a facility for re-ranging by the user. It is available in standard ranges from 0-10 to 0-100 metres water gauge, or may be scaled to customer requirements. All ranges are available in gauge or absolute format.
FEATURES ● ● ● ● ● ● ●
DESCRIPTION The P6420-26 pressure transmitter is based on a four active arm strain gauge bridge fused to a high purity ceramic diaphragm, offering high natural output coupled with superb chemical and corrosion resistance. It offers a two wire, 4-20mA output proportional to liquid level. The sensing element and its associated electronics are housed in a rugged two part stainless steel case, which provides access to the 5:1 turndown facility DIL switches and zero & span potentiometers. The two halves are secured by means of cap headed screws and an O-ring seal, which when coupled with the IP68 sealed cable gland, provides a high integrity waterproof assembly.
●
5:1 turndown facility 4-20mA, two wire output Excellent linearity Wide temperature range Lightning protection Rugged construction Excellent long term stability Temperature compensated
OPTIONS ● ●
Low power version 9-30V Extended temperature range capability
APPLICATIONS ● ● ●
Water level/pressure Soil mechanics Tank contents
SPECIFICATION Both sensor and electronics are protected from the effects of lightning strikes by the inclusion of a lightning protection circuit.
Pressure Range Excitation Output
Span: Zero: Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Safe Over-Range Burst Pressure Pressure Connection Loading Driving Environmental Protection Electrical Connection
Insulation Resistance Long Term Stability Wetted Parts
DS2803
0-10, 20, 50 and 100 metres water gauge or absolute. Other ranges available 9-30V or 20-50Vdc unregulated (factory set) 16mA +1% 4mA +1% of span at zero pressure <+0.25% of span (best fit straight line) -10oC to 80oC -25oC to 100oC <+0.015% span/oC <+0.008% reading/oC 1.5 x rated range minimum 3 x rated range minimum G1/4 female (1/4”BSP) - for calibration purposes 1.5k Ω @ 50Vdc supply maximum Sealed to IP68 up to 100mWG Fully screened polyurethane sheathed cable with vent tube & strain wire. Red; +ve Blue; -ve White; earth >500M Ω at 500Vdc 0.1% span/12 months 303 stainless steel, alumina ceramic and nitrile rubber seals (other seal materials available)
Page 1 of 2
SWITCH POSITION DETAILS Turndown Ratio 1:1 2:1 3:1 4:1 5:1
Switch 1
Switch 2
Switch 3
Switch 4
off on off off off
off off on off off
off off off on off
on off off off off
OUTLINE DETAILS
Cable: 4-core polyurethane sheathed with strain relief wire and vent tube
Cable gland, sealed to IP68, 10 bar
ADJUSTMENT CONTROLS LAYOUT
Cover, 303 stainless steel. Removable for zero and span adjustment
ON
1 2 3 4 SWITCH
120
Case, 303 stainless steel
Zero adjust Span adjust
29 Self flushing UPVC nose cone
Dimensions mm
ø40
Submersible transducers and transmitters must be installed to the RM&C recommended method, please contact the Bramley sales office (on +44 (0)1256 884 900) for details.
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
04HWAR0211
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2803
Page 2 of 2
PRESSURE Product Data Sheet
DS2804
Sensit P6420-57 Abrasive Material Pressure Transmitter The Sensit P6420-57 is a pressure transducer having a two wire, 4-20mA output. It is available in standard ranges from 5 bar to 50 bar, or may be scaled to customer requirements.
DESCRIPTION The P6420-57 pressure transducer is based on a four active arm strain gauge bridge fused to a high purity ceramic diaphragm, offering high natural output coupled with superb chemical and corrosion resistance. It has been designed primarily for use with concrete slurry and other abrasive fluids and has a cavity free, flush sensing diaphragm covered by a flexible polypropylene shield.
SPECIFICATION Pressure Range Excitation Output
Span: Zero: Non Linearity, Hysteresis & Repeatability (NLH) Operating Temp Range Safe Over-range Burst Pressure Insulation Resistance Loading Driving Environmental Protection Electrical Connections
5,10, 20, & 50 bar SG and G 10-32Vdc unregulated 16mA +1% of span at pressure 4mA +1% of span at zero pressure <+1% of span (best fit straight line) -25oC to +100oC 1.5 times rated range 3 times rated range minimum >500M Ω at 500Vdc, over the operable temperature range 1k Ω @ 28Vdc supply IP68 Cable
It offers a two wire, 4-20mA output proportional to fluid pressure with other outputs available as options. The sensing element and its associated electronics are housed in a rugged stainless steel case.
FEATURES ● ● ● ● ● ● ●
Superb chemical and corrosion resistance 4-20mA, two wire operation (option 5-21mA) Unrivalled abrasion resistance Wide temperature range High electrical isolation Rugged construction Excellent long term stability
APPLICATIONS ●
● ● ●
Concrete pumping & other abrasive applications Gypsum Brick dust Clay
DS2804
Page 1 of 2
DIMENSIONAL DETAILS DIMENSIONS (mm)
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
04HWAR0510
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2804
Page 2 of 2
PRESSURE Product Data Sheet
DS2805
Sensit HPS-A Series 4-20mA Output Pressure Transmitter Two wire, 4-20mA output transmitters offering superb chemical and corrosion resistance. Gauge or Absolute pressure is detected using a four active arm strain gauge bridge sensor, fused to a high-purity ceramic diaphragm. Available in three classes of accuracy and compensation specified below, with ranges from 100mbar to 600 bar or scaled to customer requirements. ● ● ● ● ● ●
Stainless Steel housing Rugged construction Excellent linearity Excellent long term stability Wide temperature range Intrinsically safe versions available
CLASS A HIGH SPECIFICATION TRANSMITTER Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Long Term Stability Power Supply Loop Resistance
16mA ±0.5% 4mA ±0.5% of span ±0.1% of span (best fit straight line) -20oC to 125oC -20oC to 125oC 0 to 100oC, ±0.01% of span / oC <0oC & >100oC, ±0.015% span / oC o ±0.015% reading/ C typical 0.1% / 12 months typical 10 to 32Vdc 1.1k Ω max @32Vdc supply
CLASS B INDUSTRIAL TRANSMITTER Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Long Term Stability Power Supply Loop Resistance
DS2805
CLASS C GENERAL PURPOSE/OEM TRANSMITTER Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Long Term Stability Power Supply Loop Resistance
16mA ±1% 4mA ±1% of span ±0.25% of span (best fit straight line) -0oC to 80oC -20oC to 125oC ±0.04% span / oC ±0.015% reading / oC typical 0.1% / 12 months typical 10 to 32Vdc 1.1k Ω max @32Vdc supply
OPTIONS Pressure Connection G1/4” BSP male or female G1/2” BSP male 1/4” NPT male or female 1/2” NPT male Others available on request Electrical Connection IP65 mini plug & socket IP65 large plug & socket IP65 cable & ferrule IP68 glanded cable Others available on request Housing Material 316L Stainless Steel Others available on request Intrinsically Safe EEx ia IIC T4
16mA ±1% 4mA ±1% of span ±0.15% of span (best fit straight line) -0oC to 100oC -20oC to 125oC ±0.015% span / oC ±0.015% reading/ oC typical 0.1% / 12 months typical 10 to 32Vdc 1.1k Ω max @32Vdc supply
Page 1 of 2
DIMENSIONS (mm) IP65 CABLE & FERRULE
IP68 GLANDED CABLE
4 Core Black PTFE Cable 4 Core Cable with Vent Tube & Strain Wire
LABEL
TIG Welds
75 up to 50 bar
Case & Cover Material 316L ST ST
Cable Outlet, Sleeved & Bonded
81 (100 & 200 bar) 85 above 200 bar
90 up to 50 bar 96 (100 & 200 bar) 101 above 200 bar
Gland IP68 to 10 bar
Case & Cover Material 316L ST ST
LABEL
TIG Welds
*Hex 18 A/F *Hex 18 A/F
Ø 25
DIN 40050 PLUG & SOCKET
DIN 43650 PLUG & SOCKET
Mini DIN Connector to DIN 40050
Case & Cover Material 316L ST ST
LABEL
TIG Welds
75 Up to 50 bar
DIN 43650 Connector
81 (100 & 200 bar) 90 above 200 bar
75 up to 50 bar 81 (100 & 200 bar) 84.5 above 200 bar
Pressure Port G1/4 (other sizes available)
Ø 25
Pressure Port G1/4 (other sizes available)
Case & Cover Material 316L ST ST
LABEL
*Hex 18 A/F
*Hex 18 A/F
Ø25
TIG Welds
Pressure Port G1/4 (other sizes available)
Ø25
Pressure Port G1/4 (other sizes available)
* Note: >200 bar, Hexagon 27 A/F and diameter 27
SENSIT pressure transducers are also available with the following outputs: ● ● ●
Voltage : 0-5V, 0-10V or 1-5V Active mV : 0-100mV or 0-200mV mA : 4-20mA
MECHANICAL SPECIFICATION Safe Over-range Pressure Burst Pressure Wetted Materials
1.5 x rated range 3 x rated range minimum Stainless steel, alumina ceramic, Viton (other O-ring materials available)
For level or depth measurement, use the NEW TRIDENT Series of submersible pressure transducers, or if your application requires something special, contact sales. If we do not already have the solution our OEM design team are ready to help. Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
05HWAR0510
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2805
Page 2 of 2
An
Brand
PRESSURE Product Data Sheet
DS2811
P193 Pressure Capsule The P193 pressure sensor is a low cost pressure capsule available in standard ranges from 100mbar to 600 bar. All ranges are available in gauge or absolute format. It is ideal for continuous use in applications where the pressure medium is wet and corrosive and long term stability is of prime importance.
DESCRIPTION The type P193 pressure sensor is manufactured from high purity alumina ceramic. This material possesses superb chemical and abrasion resistance, making it unrivalled for use with virtually any pressure medium. The diaphragm of the sensing element has a fouractive-arm strain gauge bridge fused to its inner face. This direct fusion ensures excellent long term stability and repeatability, which, coupled with the matched bridge network, provides excellent linear thermal characteristics.
DS2811
SPECIFICATION Range (bar) Sensitivity Non Linearity Thermal Zero Shift Thermal Span Shift Output Tolerance Zero Output Supply Voltage Operating Temperature Range Safe Over-range without Calibration Change Burst Pressure Bridge Resistance
0-100mbar to 0-600 bar 1.0 - 5.0 mV/V dependent on range <±0.25% of span (best fit straight line) <±0.04% span / oC typical <-0.04% reading / oC typical ±30% <±0.2mV/V 1-30Vdc -25 to 125oC 1.5 x minimum 3 x range minimum 10k Ω ±30%
FEATURES ●
Superb chemical and corrosion resistance
●
High output
●
High bridge resistance
●
Excellent linearity
●
Low cost
●
Low supply current
●
High electrical isolation
●
Excellent long term stability
●
Small size
●
Bridge balanced at zero applied pressure
Issue 4: 12.01.06
Page 1 of 2
DIMENSIONAL DETAILS
Connection pads on 2.54 (0.1”) pitch
Vent hole, sealed on absolute versions
Range (bar) 0.1 0.4 1 2 3 5 10 20 50 100 200 400 600
18.6/19.0
Hermetic glass seal
T
T Sensitivity (mm, nominal) (mV/V) ±30%
INSTALLATION DETAILS
6.2 6.2 6.2 6.3 6.35 6.4 6.5 6.6 6.8 7.3 7.8 8.6 9.5
APPLICATIONS
-output -supply
● ● ●
+output +supply
● ●
O-RING DETAILS Ø19.2/19.4 Ø15.5 min
Range
Size
A
●
B
0.1-100 bar 12 x 2 1.35/1.45 16.1/15.95 200-600 bar 7 x 2 1.40/1.50 11.20/11.10
● ● ● ● ●
Sensor
●
A ●
O-ring
● ● ●
Ø To suit O-ring ØB
0.9 2.2 3.0 3.0 3.0 3.5 4.0 5.0 4.5 4.0 5.0 4.0 3.0
●
Water level/pressure Data logging Chemical processing Soil mechanics Load measurement Automotive Printing Medical engineering Air compressors Gas flow Pneumatic controls Central heating Hydraulic machinery Air conditioning Tank contents Crop spraying Paper processing
All dimensions in mm
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2811
Issue 4: 12.01.06
Page 2 of 2
An
PRESSURE
Brand
Product Data Sheet P6420-67 Abrasive Material Pressure Transmitter The P6420-67 is a pressure transducer having a two wire, 4-20mA output. It is available in standard ranges from 5 bar to 50 bar, or may be scaled to customer requirements.
DESCRIPTION The P6420-67 pressure transducer is based on a four active arm strain gauge bridge fused to a high purity ceramic diaphragm, offering high natural output coupled with superb chemical and corrosion resistance. It has been designed primarily for use with slurry and other abrasive fluids and has a cavity free, flush sensing diaphragm covered by a flexible polypropylene shield.
SPECIFICATION Pressure Range Excitation Output
Span Zero Non Linearity, Hysteresis & Repeatability (NLH) Operating Temp Range Safe Over-range Burst Pressure Insulation Resistance Loading Driving Environmental Protection Electrical Connections
8, 10, 16, 20 and 50 bar SG and G 10-32Vdc unregulated 16mA +1% 4mA +1% of span <±5% of span (best fit straight line) -25oC to 100oC 1.5 times rated range 3 times rated range minimum >500M Ω at 500Vdc, over the operable temperature range 1k Ω @ 28Vdc supply IP66 Niphan plug and socket
It offers a two wire, 4-20mA output proportional to fluid pressure with other outputs available as options. The sensing element and its associated electronics are housed in a rugged stainless steel case.
FEATURES ● ● ● ● ● ● ● ●
Superb chemical and corrosion resistance 4-20mA, two wire operation Unrivalled abrasion resistance Wide temperature range High electrical isolation Rugged construction Excellent long term stability Temperature compensated
APPLICATIONS ●
Concrete pumping & other abrasive applications
●
Gypsum
●
Brick dust
●
Clay
DS2815
Issue 1: 31.07.06
Page 1 of 2
DIMENSIONAL DETAILS
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
0043
DS2815
10 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884900 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
Issue 1: 31.07.06
CERTIFICATE NO. 22358
Page 2 of 2
PRESSURE Product Data Sheet
DS2816
Sensit P6420-61 Abrasive Material Pressure Transmitter The P6420-61 is a pressure transducer having a two wire, 4-20mA output. It is available in standard ranges from 5bar to 50bar, or may be scaled to customer requirements.
DESCRIPTION The P6420-61 pressure transducer is based on a four active arm strain gauge bridge fused to a high purity ceramic diaphragm, offering high natural output coupled with superb chemical and corrosion resistance. It has been designed primarily for use with concrete slurry and other abrasive fluids and has a cavity free, flush sensing diaphragm covered by a flexible polypropylene shield.
SPECIFICATION Pressure Range Excitation Output Span: Zero: Non Linearity, Hysteresis & Repeatability (NLH) Operating Temp Range Safe Over-range Burst Pressure Insulation Resistance Loading Driving Environmental Protection Electrical Connections
5,10, 20 & 50 bar SG and G 10-32Vdc unregulated 16mA +1% of span at pressure 4mA +1% of span at zero pressure <+1% of span (best fit straight line) -25oC to 100oC 1.5 times rated range 3 times rated range minimum >500M Ω at 500Vdc, over the operable temperature range 1k Ω @ 28Vdc supply IP67 Terminal Head (IP67)
It offers a two wire, 4-20mA output proportional to fluid pressure with other outputs available as options. The sensing element and its associated electronics are housed in a rugged stainless steel case.
FEATURES ● ● ● ● ● ● ●
Superb chemical and corrosion resistance 4-20mA, two wire operation (option 5-21mA) Unrivalled abrasion resistance Wide temperature range High electrical isolation Rugged construction Excellent long term stability
APPLICATIONS ●
● ● ●
Concrete pumping & other abrasive applications Gypsum Brick Dust Clay
DS2816
Page 1 of 2
DIMENSIONAL DETAILS
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
03HWAR0510
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
0043
DS2816
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884900 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
CERTIFICATE NO. 22358
Page 2 of 2
PRESSURE Product Data Sheet
DS2810
Sensit OEM 4-20mA Output Pressure Transmitter The M6420-50 is a two wire, 4-20mA pressure transmitter and is available in standard ranges from 0.5 bar to 600 bar, or may be scaled to customer requirements. All ranges are available in gauge or absolute format.
FEATURES
DESCRIPTION The M6420-50 pressure transmitter is based on a four active arm strain gauge bridge fused to a high purity alumina ceramic diaphragm, offering high natural output coupled with superb chemical and corrosion resistance. This is housed within a stainless steel case with integral electronics and is supplied with a plug and socket electrical connection. Pressure connection is a G1/4 male thread as standard. Other threads are available on request.
Rugged construction / small size
4-20mA output
Excellent linearity
Cost effective
High electrical isolation
Excellent long term stability
SPECIFICATION Pressure Range Excitation Output - Span Output - Zero Non Linearity, Hysteresis & Repeatability (NLH) Operating Temp Range Thermal Zero Shift Thermal Span Shift Safe Over-range Pressure Burst Pressure Output Resistance Load Driving Environmental Rating Insulation/Isolation Resistance
DS2810
Available in ranges between 0.5 bar and 600 bar gauge or absolute 10-32Vdc 16mA ±1% of span at zero pressure 4mA ±1% span ±0.25% of span (best fit straight line) -25ºC to 80ºC <±0.08% of span/ºC typical <-0.04% reading/ºC typical 1.5 x rated range minimum 3 x rated range minimum >10M Ω 1k Ω @ 30Vdc supply IP65 >500M Ω @ 50Vdc
Page 1 of 2
APPLICATIONS
Water level/pressure Data logging Chemical processing Soil mechanics Load measurement automotive Hydraulic machinery
Air conditioning Tank contents Crop spraying Paper processing Printing Medical engineering
Air compressors Gas flow Pneumatic controls Central heating
OUTLINE DETAILS: (TYPE NUMBER M6420-XXX-50) DIMENSIONS (MM) Electrical Connections Pin 1 Pin 2
Ă&#x2DC;27
Positive Negative
Mini Connection to DIN40050 25
Body, 303 Stainless Steel 50
27 A/F Hex 12 Pressure Port G 1/4 (1/4â&#x20AC;? BSP)
Wetted materials ceramic (AI203), stainless steel and Viton
Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.
04HWAR0510
Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838
1-4 Campbell Court, Bramley, Tadley, Hampshire, RG26 5EG, England Tel: +44(0)1256 884901 Fax: +44(0)1256 882986 email: sales@roxspur.com www.roxspur.com
DS2810