Electrak ... 速
powering the workstation
UNDERFLOOR TO WORKSTATION / SYSTEM guide
POWERED BY SPECIALISTS
Global strength built on local knowledge
Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the driving force behind its development. With an increasing investment in research and development (circa 5% of sales) and more than 4,000 active patents, the Legrand Group is focused on maintaining a high rate of new product launches that present innovative solutions to the market.
Legrand in the UK - powered by specialists
In the UK Legrand has developed a customer focused structure which harnesses the power of its market leading specialist brands including Bticino, Electrak and Zucchini to deliver innovative, integrated solutions for every phase of construction.
LEGRAND’S POWER DISTRIBUTION DIVISION From Zucchini transformers, through rising main busbars and distribution boards to Electrak’s power track, desk modules and lighting control, Legrand’s power distribution division provides market leading solutions to the increasing demands of today’s buildings.
contents
sustainable development From design through to manufacturing, the Legrand Group selects materials and processes that respect people and the environment. • Efficient and environmentally aware product design • Product functions that help to avoid energy waste • Management of manufacturing and logistics sites • I ntegration of environmental concerns and ISO 14001 procedures at the Group’s global sites*
* 84% of sites are ISO 14001:2004 accredited including all UK sites.
POWER TRACK Overview Ordering information Technical information
8 10 17
FLOOR BOXES Overview Ordering information Technical information
22 24 29
GROMMETS Overview Ordering information Technical information
30 32 33
INTERSOC-R Overview Ordering information Technical information
34 38 44
Electrak ... the specialist in power 速
distribution throughout the workplace Electrak, part of the Legrand Group in the UK, is a leading manufacturer of power distribution and lighting control solutions. Its power track, floor boxes, grommets, desk modules and lighting control ranges are installed in high specification offices around the world.
04
Powering the workstation UNDERFLOOR POWER Electrak’s power track system is perfect for supplying underfloor power in cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes, this flexible, easy to install system can be reconfigured as office layouts evolve.
POWER TRACK See page 8
CAVITY FLOOR BOXES See page 22
WORKSTATION POWER Electrak’s access grommets provide the gateway for power to feed from the underfloor power track network to the workstation, where all desk power requirements are met with our new range of desk modules, Intersoc-R.
GROMMETS See page 30
INTERSOC-R See page 34
05
fully addressable lighting control Designed to work in harmony with Electrak’s buscom trunking, Lightrak’s lighting control system offers high end sophistication with unbeatable flexibility and speed of installation. Find out more at www.electrak.co.uk
BUSCOM power and data backbone
LIGHTRAK lighting control system
Electrak ... ÂŽ
UK manufacturing. Global recognition 30 years of experience Electrak has been designing and manufacturing cost effective systems that distribute power reliably and safely throughout the workplace since the 1980s. As the inventor of underfloor busbar systems, Electrak sets the benchmark for flexible power distribution.
INDUSTRY EXPERTS As part of its ongoing commitment to research and development, Electrak continually evolves its product ranges to ensure it produces the best and most innovative solutions available on the market. Electrak takes pride in its enviable reputation for market leading customer service, industry knowledge and product expertise.
Quality assured UK manufacturing With its UK manufacturing base situated in the North East of England, Electrak adapts to the changing demands of projects by providing a rapid production process whilst ensuring quality meets the highest standards. Electrak’s products are manufactured within an ISO 9001 : 2008 facility and many carry the Intertek Diamondmark (where indicated).
06
Trusted thRoughout the UK and across the world
united kingdom
• Morgan Stanley, Canary Wharf • Media City, Manchester • JP Morgan, Canary Wharf • RBS, Edinburgh • Bridgewater Place, Leeds • Network Rail, Nationwide • Swiss Re, City of London • Amazon, Swansea • Heathrow Airport, London • Morgan Stanley, Canary Wharf • Fort Dunlop, Birmingham • Royal Bank of Canada, City of London • Snow Hill, Birmingham • Barclays Capital, Canary Wharf • Temple Back, Bristol • Standard Chartered Bank, City of London • London Underground • BBC, White City • Mann Island, Liverpool
Middle East & India
• ADMA-OPCO HQ, Dubai • Internet City, Dubai • Burjuman Centre, Dubai • ADIC/Al Bahr Towers, Abu Dhabi • Al Dar HQ, Abu Dhabi • Central Bank of Kuwait • Ministry of Education, Kuwait • PIFFS Aridya, Kuwait • PAAET, Kuwait • Qatar News Agency • Barclays, Chennai, India • Barclays, Pune, India • Barclays, Andheri, India • Barclays, Mumbai, India • RBS, Delhi, India • Fidelity, Delhi, India
Asia Pacific
• Credit Suisse, ICC I, Hong Kong • Deutsche Bank, ICC I, Hong Kong • Barclays Capital, Cheung Kong Centre • Customs Headquarters, North Point, Hong Kong • Standard Chartered Bank, IFC II, Hong Kong • Citi Bank Tower, Hong Kong • Macquarie Bank, IFC I, Hong Kong • UBS Bank, IFC II, Hong Kong • JP Morgan, Hong Kong • Standard Chartered Bank, Marina Bay, Singapore • Barclays Capital, Marina Bay, Singapore • Nomura Bank, Marina Bay, Singapore • Credit Suisse, Serangoon Road, Singapore • ABN Amro, One Raffles Quay, Singapore • RBS, One George Street, Singapore • Barclays Capital, Shanghai • Standard Chartered Bank, Shanghai • UBS Bank, Shanghai
07
Power track...
adaptable, reliable underfloor power
08
THE INDUSTRY STANDARD IN UNDERFLOOR POWER Electrak’s power track system is perfect for cavity floor installations. With minimal parts, push-fit assembly and a complementary range of floor boxes and grommets, this flexible, easy to install system can be reconfigured as office layouts evolve.
Integral track connector plugs into feed unit
Lengths simply push-fit together
Integral fixing brackets for rapid installation
Tap-offs plug in to shuttered socket outlets and lock on to track body
The system consists of continuous lengths of track which are fed via a feed unit and can be installed in floor voids as low as 48mm. • 63 A rated, IP 40 protection • Available in five versions: single phase, clean earth, dual circuit, three phase and auxiliary earth • Available in 1.2m, 1.8m, 2.4m and 3.6m lengths • Tap-off outlets are located at every 300 or 600mm pitch • Floor mountable (stand-off brackets also available)
09
Electrak® power track systems
Length (m)
Description Track lengths with 300 mm socket centres
4 sockets
1·2
6 sockets
1·8
8 sockets
2·4
12 sockets
3·6
–
Excluding cables and conduit
–
Flexible metal conduit
1·2
Flexible metal conduit
2·4
3 5 3 5 3 5
3 5 3 5 3 5
3
5
3
5
3
5
3
5
3
5
Track feed
Standard tap-off / auxiliary earth tap-off
32 A unfused 16 mm Ø L, N, PE 13 A fused 16 mm Ø L, N, PE 13 A 543·7 fused 16 mm Ø L, N, PE Low noise / clean earth tap-off
32 A unfused 16 mm Ø CE, L, N, PE 13 A fused 16 mm Ø CE, L, N, PE 13 A 543·7 fused 16 mm Ø CE, L, N, PE Dual circuit tap-off
32 A unfused 20 mm Ø CE, L1, N1 L2, N2, PE
3 phase tap-off
32 A 415 V 3 phase 20 mm Ø L1, L2, L3, N, PE 32 A L1 unfused reconfigurable live pin 16 mm Ø L1, N, PE 32 A L2 unfused reconfigurable live pin 16 mm Ø L2, N, PE 32 A L3 unfused reconfigurable live pin 16 mm Ø L3, N, PE
Key code / Busbar arrangement
10
010_011_Electrak v2.indd 10
20/12/2012 12:39
ELECTRAK 24
ELECTRAK 25
ELECTRAK 26
ELECTRAK 27
ELECTRAK 28
Standard system (white)
Low noise / clean earth system (green)
Dual circuit system (dark green)
3 phase system (grey)
Auxiliary earth system (red)
DA1123
JA2123
KA3123
NA4123
YA5123
DA1183
JA2183
KA3183
NA4183
YA5183
DA1243
JA2243
KA3243
NA4243
YA5243
DA1363
JA2363
KA3363
NA4363
YA5363
DF1010
JF2010
KF3010
NF4010
YF5010
DW1000
JW2000
KW3000
NW4000
YW5000
DW1010
JW2010
KW3010
NW4010
YW5010
DW1020
JW2020
KW3020
NW4020
YW5020
DP1332 DP1532 DP1313 DP1513 DP1327 DP1527
– – – – – –
DP1332 DP1532 DP1313 DP1513 DP1327 DP1527
– – – – – –
YP5332 YP5532 YP5313 YP5513 YP5327 YP5527
– – – – – –
JP2332 JP2532 JP2313 JP2513 JP2327 JP2527
JP2332 JP2532 JP2313 JP2513 JP2327 JP2527
– – – – – –
– – – – – –
–
–
KP3328
–
–
–
–
KP3528
–
–
–
–
–
NZ4331
–
–
–
–
NZ4531
–
–
–
–
NP4332(1)
–
–
–
–
NP4532(1)
–
–
–
–
NP4302(1)
–
–
–
–
(1)
NP4502
–
–
–
–
NP4303(1)
–
–
–
–
NP4503(1)
–
PE
N2 L2
PE CE N1 L1
PE CE N1 L1 N2 L2
PE N L1 L2 L3
PE N1 L1
(1) All NP tap-offs are reconfigurable between L1, L2 or L3 for 3 phase track
11
010_011_Electrak v2.indd 11
20/12/2012 12:39
Electrak® 24 power track system standard system (white)
DF1010
- - -/
---
DW1010
DA1123
picto loupe-65765j.eps
DP1332
Selection chart (p. 10-11) Dimensions and technical information (p. 17-21) Approved to ASTA Standard 138 and ISO 9001 : 2008 Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
1 1 1 1
Track system components
Pack
Cat. Nos.
Electrak 24 standard track lengths
rack lengths fit together using the integral T connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1·2 m, 4 sockets, 2 floor fixing brackets 1·8 m, 6 sockets, 2 floor fixing brackets 2·4 m, 8 sockets, 2 floor fixing brackets 3·6 m, 12 sockets, 3 floor fixing brackets
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit(1) Tap-off units in excess of 3 m should only be used if they contain a fuse or if the power track is protected by a protective device not exceeding 32 A
32 A unfused
1 1
1 1
1 1
DA1123 DA1183 DA1243 DA1363
1
1 1 1
1 1
DZ1210 DZ1230
Track feed unit
DF1010 W ith one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks
Can be used to overcome obstructions or as corners where required DW1000 Excluding cables and conduit DW1010 1·2 m flexible metal conduit DW1020 2·4 m flexible metal conduit
Tap-off units
6 mm Ø‚ L, N, PE 1 DP1332 3 m DP1532 5 m
13 A fused
6 mm Ø‚ L, N, PE 1 DP1313 3 m DP1513 5 m
13 A 543·7 fused - high integrity
6 mm Ø‚ L, N, PE 1 DP1327 3 m DP1527 5 m
Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart For fitting under track body and track feed For fitting under integral track connectors
(1) Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 845 600 6266
12
012_013_Electrak v3.indd 12
20/12/2012 12:38
Electrak® 25 power track system low noise / clean earth system (green)
JF2010
- - -/
---
JW2010
JA2123
picto loupe-65765j.eps
JP2332
Selection chart (p. 10-11) Dimensions and technical information (p. 17-21) Approved to ASTA Standard 138 and ISO 9001 : 2008 Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
1 1 1 1
Track system components
Pack
Cat. Nos.
Electrak 25 low noise / clean earth track lengths
rack lengths fit together using the integral T connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1·2 m, 4 sockets, 2 floor fixing brackets 1·8 m, 6 sockets, 2 floor fixing brackets 2·4 m, 8 sockets, 2 floor fixing brackets 3·6 m, 12 sockets, 3 floor fixing brackets
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit(1) Tap-off units in excess of 3 m should only be used if they contain a fuse or if the power track is protected by a protective device not exceeding 32 A
32 A unfused
1 1
1 1
1 1
JA2123 JA2183 JA2243 JA2363
1
1 1 1
1 1
DZ1210 DZ1230
Track feed unit
JF2010 W ith one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks
Can be used to overcome obstructions or as corners where required JW2000 Excluding cables and conduit JW2010 1·2 m flexible metal conduit JW2020 2·4 m flexible metal conduit
Tap-off units
6 mm Ø‚ CE, L, N, PE 1 JP2332 3 m JP2532 5 m
13 A fused
6 mm Ø‚ CE, L, N, PE 1 JP2313 3 m JP2513 5 m
13 A 543·7 fused - high integrity
6 mm Ø‚ CE, L, N, PE 1 JP2327 3 m JP2527 5 m
Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart For fitting under track body and track feed For fitting under integral track connectors
(1) Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 845 600 6266
13
012_013_Electrak v3.indd 13
20/12/2012 12:38
Electrak® 26 power track system dual circuit system (dark green)
KF3010
- - -/
---
KW3010
KA3123
picto loupe-65765j.eps
KP3328
Selection chart (p. 10-11) Dimensions and technical information (p. 17-21) Approved to ASTA Standard 138 and ISO 9001 : 2008 Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
Track system components
Pack
Cat. Nos.
The dual power track system has both standard and low noise / clean earth systems incorporated
Electrak 26 dual circuit track lengths
rack lengths fit together using the integral T connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1·2 m, 4 sockets, 2 floor fixing brackets 1·8 m, 6 sockets, 2 floor fixing brackets 2·4 m, 8 sockets, 2 floor fixing brackets 3·6 m, 12 sockets, 3 floor fixing brackets
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit(1) Tap-off units in excess of 3 m should only be used if they contain a fuse or if the power track is protected by a protective device not exceeding 32 A
Standard 32 A unfused
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1 1 1
KA3123 KA3183 KA3243 KA3363
1
1 1 1
1 1
DZ1210 DZ1230
Track feed unit
KF3010 W ith two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks
Can be used to overcome obstructions or as corners where required KW3000 Excluding cables and conduit KW3010 1·2 m flexible metal conduit KW3020 2·4 m flexible metal conduit Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart For fitting under track body and track feed For fitting under integral track connectors
Tap-off units
6 mm Ø‚ L, N, PE 1 DP1332 3 m DP1532 5 m
Standard 13 A fused
6 mm Ø‚ L, N, PE 1 DP1313 3 m DP1513 5 m
Standard 13 A 543·7 fused
6 mm Ø‚ L, N, PE 1 DP1327 3 m DP1527 5 m
Low noise / clean earth 32 A unfused
6 mm Ø‚ CE, L, N, PE 1 JP2332 3 m JP2532 5 m
Low noise / clean earth 13 A fused
6 mm Ø‚ CE, L, N, PE 1 JP2313 3 m JP2513 5 m
Low noise / clean earth 13 A 543·7 fused
6 mm Ø‚ CE, L, N, PE 1 JP2327 3 m JP2527 5 m
Dual circuit 32 A unfused
0 mm Ø‚ CE, L1, N1, L2, N2,PE 2 KP3328 3 m KP3528 5 m
(1) Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 845 600 6266
14
014_015_Electrak v3.indd 14
20/12/2012 12:43
Electrak® 27 power track system 3 phase system (grey)
NF4010
- - -/
---
NW4010
NA4123
picto loupe-65765j.eps
NZ4331
Selection chart (p. 10-11) Dimensions and technical information (p. 17-21) Approved to ASTA Standard 138 and ISO 9001 : 2008 Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm
Track system components
Pack
Cat. Nos.
Electrak 27 3 phase track lengths
rack lengths fit together using the integral T connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1·2 m, 4 sockets, 2 floor fixing brackets 1·8 m, 6 sockets, 2 floor fixing brackets 2·4 m, 8 sockets, 2 floor fixing brackets 3·6 m, 12 sockets, 3 floor fixing brackets
Pack
1 1 1 1
Cat. Nos.
NA4123 NA4183 NA4243 NA4363
1
1 1 1
Track feed unit
NF4010 W ith one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks
Can be used to overcome obstructions or as corners where required NW4000 Excluding cables and conduit NW4010 1·2 m flexible metal conduit NW4020 2·4 m flexible metal conduit
Special fixing brackets
1 1
Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart DZ1210 For fitting under track body and track feed DZ1230 For fitting under integral track connectors
1 1
1 1
1 1
1 1
32 A L1(2) unfused
nfused U Reconfigurable live pin 16 mm Ø‚ L, N, PE NP4332 3 m NP4532 5 m 32 A L2(2) unfused
nfused U Reconfigurable live pin 16 mm Ø‚ L, N, PE NP4302 3 m NP4502 5 m
32 A 415 V 3 phase
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit(1) Tap-off units in excess of 3 m should only be used if they contain a fuse or if the power track is protected by a protective device not exceeding 32 A
0 mm Ø‚ L1, L2, L3, N, PE 2 NZ4331 3 m NZ4531 5 m
Tap-off units
32 A L3(2) unfused
nfused U Reconfigurable live pin 16 mm Ø‚ L, N, PE NP4303 3 m NP4503 5 m
(1) Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 845 600 6266 (2) All NP tap-offs are reconfigurable between L1, L2, or L3 for 3 phase track
15
014_015_Electrak v3.indd 15
20/12/2012 12:43
Electrak® 28 power track system auxiliary earth system (red)
YF5010
- - -/
---
YW5010
YA5123
picto loupe-65765j.eps
YP5332
Selection chart (p. 10-11) Dimensions and technical information (p. 17-21) Approved to ASTA Standard 138 and ISO 9001 : 2008 Conforms to BS EN 60439-2 : 2008. Fully complies with the requirements of BS 7671 : 2008 IEE Wiring Regulations A compact system that can be installed in floor voids as low as 48 mm
Pack
Cat. Nos.
1 1 1 1
Track system components
Pack
Cat. Nos.
Electrak 28 auxiliary earth track lengths
rack lengths fit together using the integral T connectors on each length Track lengths should always be secured using the integral floor fixing brackets 300 mm socket centres 1·2 m, 4 sockets, 2 floor fixing brackets 1·8 m, 6 sockets, 2 floor fixing brackets 2·4 m, 8 sockets, 2 floor fixing brackets 3·6 m, 12 sockets, 3 floor fixing brackets
Tap-off length is determined by the cable and not the conduit length, e.g. a 3 m tap-off has 3 m of cable and 2·6 m of flexible metal conduit(1) Tap-off units in excess of 3 m should only be used if they contain a fuse or if the power track is protected by a protective device not exceeding 32 A
32 A unfused
1 1
1 1
1 1
YA5123 YA5183 YA5243 YA5363
1
1 1 1
1 1
DZ1210 DZ1230
Track feed unit
YF5010 W ith one 25 mm diameter hole suitable for MICC, armoured cables or single core cables in conduit Flexible interlinks
Can be used to overcome obstructions or as corners where required YW5000 Excluding cables and conduit YW5010 1·2 m flexible metal conduit YW5020 2·4 m flexible metal conduit
Tap-off units
6 mm Ø‚ L, N, PE 1 YP5332 3 m YP5532 5 m
13 A fused
6 mm Ø‚ L, N, PE 1 YP5313 3 m YP5513 5 m
13 A 543·7 fused - high integrity
6 mm Ø‚ L, N, PE 1 YP5327 3 m YP5527 5 m
Special fixing brackets Required when track is raised off surface level Brackets raise track by 21 mm and should be spaced 600 mm apart For fitting under track body and track feed For fitting under integral track connectors
(1) Tap-offs are supplied as standard with flexible metal conduit For alternative wiring solutions, contact us on +44 (0) 845 600 6266
16
016_Electrak v3.indd 16
20/12/2012 12:58
Electrak® power track systems design and installation
n General installation notes
n Special fixing brackets
Electrak power track is a compact system that can be installed in floor voids as low as 48 mm
When installing track off-floor, Electrak special fixing brackets raise track by 21 mm. Ensure brackets are spaced 600 mm apart and always have support under the integral track connector and track feed. Failure to do so may undermine the integrity of the system
Track feed boxes are provided with one or two 25 mm diameter holes suitable for MICC, armoured cables or single core cables in conduit Track lengths connect together and to track feeds using the integral connectors on each length Track lengths should always be secured using the integral floor fixing brackets ; three on the 3·6 m length and two on 2·4 m, 1·8 m or 1·2 m lengths
Cat. No. DZ1210 raised off-floor fixing brackets are spaced at 600 mm centres along track. Also use bottom half of bracket under track feed and flexible interlink Cat. No. DZ1230 raised off-floor fixing brackets are always used under integral track connectors. Track is secured to raised brackets using the track’s integral fixing bracket
Access to power is provided along the track length by simply plugging tap-off units into shuttered socket outlets. These tap-off units feed all types of conventional floor service outlet boxes or feed workstations directly through the floor via 4 mm2 or 1·5 mm2 insulated conductors contained in flexible metal or VO rated nylon conduit. When connecting tap-offs directly through the floor via grommet outlets to workstations care must be taken to ensure that the tap-off length is adequate Integral track fixing bracket screws to special bracket
The dual power track system has both standard and low noise / clean earth systems incorporated. As well as dual tap-offs, both standard and low noise / clean earth tap-offs can be plugged into any socket outlet along the track length. The dual tap-off incorporates both standard and low noise cables Optimum layout flexibility is achieved by positioning track lengths a maximum of 5·2 m apart and 2·5 m from the wall, and by connecting the 3 m tap-off units to floor outlet boxes. This means every part of the floor area can be served. Flexible interlinks can be used to overcome obstructions or used as corners if required
Integral track connector
50 mm
185 mm
7 mm Ø
7 mm Ø
99 mm
Cat. No. DZ1210
21 mm to underside of track 36 mm to top of track
Cat. No. DZ1230
n Dimensions
75
93
250 46
46 2 x 25 Ø
109
68
118
47
32
15
25 Ø
65
End view A
End view B
92
Integral fixing bracket fixing centres
2·5 m
Example floor layout
track feed
5·2 m
5·2 m
5·2 m
socket outlet points every 300 or 600 mm along track length
3 m flexible tap-off unit
floor service outlet box
integral track connectors
All dimensions (mm) are nominal
17
017_021_Electrak v3.indd 17
20/12/2012 13:00
Electrak® power track systems design and installation (continued)
n Product configuration Tap-off connection
Flexible interlink Track and flexible interlink boxes must be securely fixed inline to surface so no movement can take place after fixing
Depress tap-off side clips and push down Tap-off
Side clip Push down
Interlink feed entry socket. Remove dust cover label
Remove dust cover from power track end entry socket before use
Power track Make sure both tapoff side clips are fully pushed home on both sides of track
Screw fix to surface
Track feed (Cat. No. DF1010) Sub-cabling
Tap-off connection Tap-off metal flexible conduit
Track feed protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
20 mm Ø conduit fitting. Tighten back nut securely
Connector terminals
Lift terminal tab to access terminal screws and close after use
25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
Track feed (Cat. No. JF2010) Sub-cabling
Tap-off connection Tap-off metal flexible conduit
Track feed protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
Connector terminals
20 mm Ø conduit fitting Tighten back nut securely
Lift terminal tab to access terminal screws and close after use Clean earth 25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
18
017_021_Electrak v3.indd 18
20/12/2012 13:00
Track feed (Cat. No. KF3010) Sub-cabling
Dual tap-off connection (dark green) Tap-off metal flexible conduit
Lift terminal tab to access terminal screws and close after use
Protective earth must always be connected via the earth terminal block
Track feed protective earth terminal and earth bond
Lift lid
20 mm Ø conduit fitting Tighten back nut securely
Connections L1, N1, CE = low noise L2, N2, PE = standard
Connections L1, N1, CE = low noise L2, N2, PE = standard Connector terminals Clean earth 2 x 25 mm Ø cable conduit fixing hole
Close lid and secure with lid fixing screw before power up
3 phase tap-off connection
Track feed (Cat. No. NF4010) Sub-cabling
Tap-off metal flexible conduit Track feed protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
20 mm Ø conduit fitting Tighten back nut securely
Connector terminals
Lift terminal tab to access terminal screws and close after use
25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
Tap-off connection
Track feed (Cat. No. YF5010) Sub-cabling
Tap-off metal flexible conduit Track feed protective earth terminal and earth bond Protective earth must always be connected via the earth terminal block
Lift lid
20 mm Ø conduit fitting Tighten back nut securely
Connector terminals
Lift terminal tab to access terminal screws and close after use
25 mm Ø cable conduit fixing hole Close lid and secure with lid fixing screw before power up
19
017_021_Electrak v3.indd 19
20/12/2012 13:01
Electrak庐 power track systems installation
1 Fix track feed to surface Track feed Direction of track run
Make chalk line to align track lengths
2 Connect track length to track feed Remove dust cover
Integral track connector Track length
Push down
Make sure track connector clips are fully pushed home on both sides of track
Push down
Track feed Power track and integral track connector
3 Connect additional track lengths Remove dust cover before connecting track connector
First track fixing bracket
Track outlets reusable plastic dust covers Pull out track fixing bracket lugs and screw fix on both sides
4 Secure track lengths to surface
All integral track fixing brackets must be fixed to surface at 1路2 m fixing centres from first bracket on each track length
20
017_021_Electrak v3.indd 20
20/12/2012 13:01
Electrak® power track systems technical data
n Standards
n Installations with high protective conductor currents
Approved to ASTA Standard 138 BS EN 60439-2 : 2000, BS EN 61534-22 : 2009 and IEC 61534-22 : 2009 Manufactured within an approved ISO 9001 : 2008 facility Assessed Quality Assurance Certificate No. 2029 Electrak fully complies with the requirements of BS 7671 : 2008 + A1 : 2011 (IET Wiring Regulations)
n Earth fault loop impedance BS 7671 : 2008 + A1 : 2011 IET Wiring Regulations require accurate determination of the total earth loop impedance, which must be sufficiently low to allow the protective device to operate within the specified time, which for socket outlets is 0·4 seconds. The values relevant to Electrak for calculating the earth fault loop impedance are shown in the electrical test data table, see opposite
n Durability Electrak systems are superbly designed and extremely robust. They can be expected to stand up to all normal site conditions. Electrak has been short circuit strength tested by ASTA
Volt drops (live and neutral)
Busbars Cable connector Track connector 32 A tap-off + 4 mm2 cable Flexible corner assembly + 10 mm2 cable
3·0 mV/A/m 0·4 mV/A 0·4 mV/A 0·4 mV/A 11 mV/A/m 1·5 mV/A 4·0 mV/A/m
Mechanical data
Number of conductors Busbar conductor cross sectional area Housing cross sectional area (copper equivalent) Cable terminal capacity Tap-off cable 32 A Tap-off cable 13 A fused Tap-off conduit, up to 4 conductors Tap-off conduit, 5 and 6 conductors Flexible corner cable (tri-rated, high temperature) Flexible corner conduit IP rating
3 to 6 13 mm2 13 mm2 16 mm2 4 mm2 1·5 mm2 16 mmØ 20 mmØ 10 mm2 25 mmØ 40
All unfused tap-offs comply with Regulation 543·7 without the need for additional earth conductors. Regulation 543·7·1·103 (ii) states “a single copper protective conductor having a cross-sectional area of not less than 4 mm2, complying with the requirements of Regulations 543·2 and 543·3, the protective conductor being enclosed to provide additional protection against mechanical damage, for example, within a flexible conduit” For installations with high protective conductor currents requiring fused tap-offs, a 543·7 compliant tap-off must be used. Normally fused tap-offs incorporate 1·5 mm2 conductors, however in the fused 543·7 tap-offs, the 1·5 mm2 earth conductor is replaced with a 4 mm2 conductor and therefore complies with Section 543·7·1·103 (ii)
n 32 A tap-off unit The 3 m 32 A tap-off unit comprises an unfused tap-off with either 2·6 m of 16 mm / 20 mm diameter flexible metal conduit or VO rated nylon conduit both with integral 4 mm2 LSOH conductors These units are designed to comply with regulation 434·2·1 of the IET Wiring Regulations by virtue of the following : • maximum length of cable is 3 m • it is factory assembled and fully tested item with cable installed in high quality flexible conduit Fault condition protection for the tap-off assembly and the floor box socket outlets is delivered by the circuit protection device Disconnection time for socket outlets is 0·4 seconds (Regulation 411·3·2·2). The Electrak system meets this requirement Tap-off units in excess of 3 m should only be used if they contain a fuse or the power track is protected by a protective device not exceeding 32 A
Earth fault loop impedance Phase busbar Earth busbar Earth housing Earth busbar and housing Cable connector Track connector 32 A tap-off + 4 mm2 cable Flexible corner assembly + 10 mm2 cable Rated conditional short-circuit current Ambient temperature
1·5 mΩ/m 1·5 mΩ/m 1·1 mΩ/m 0·8 mΩ/m 0·4 mΩ 0·6 mΩ 0·6 mΩ 11 mΩ/m 1·5 mΩ 4·0 mΩ/m 16 KA 25˚C
Electrical test data
Rated current Rated voltage Frequency Conductor resistance - live and neutral Conductor impedance
63 A 230/400 V~ 50/60 Hz 3·0 mΩ/m 1·5 mΩ/m
Material specifications
Power track housing Busbars Busbar insulator Track connector/socket outlet/track feed connector Socket outlet entry shutter Tap-off housing Track connector blades Tap-off blades Tap-off/flexible corner conduit, metal Tap-off conduit, plastic Tap-off cable Flexible interlink cable Track feed box/flexible interlink boxes Track feed connector terminals/earth block Track fixing brackets 13 A tap-off, fuse
Galvanised steel, natural finish High conductivity copper PTFE Flame retardant polycarbonate Acetal Flame retardant polycarbonate Copper Copper Electro-galvanised steel VO rated LSOH to BS 7211 Tri-rated to BS 6231 Galvanised steel Brass Galvanised steel To BS 1362, ASTA approved
21
017_021_Electrak v3.indd 21
20/12/2012 13:01
Floor boxes...
choice, flexibility and easy installation Electrak’s 2, 3 and 4 compartment raised access floor boxes and slab boxes offer complete versatility. Floor boxes are available pre-wired with power track tap-off, or supplied empty (unassembled), with a choice of single or separate compartment bases and three depth options. With a vast selection of power and data plates available, boxes can be tailored to the specific requirements of each office installation.
22
Rapid fit /remove mechanism adjusts for flooring thickness
Quick-fit, reversible lid for rapid installation
Durable ABS trim and lid surround
Various RCD protection options available
Available pre-wired with tap-off
Rapid fit push lock secures base in floor aperture
Three depth options: 75mm, 85mm, 110mm
Single or separate compartment bases
23 Available in 2, 3 and 4 compartments and with a choice of three depths, Electrak’s floor boxes have been developed with a host of special features: • Available pre-wired with tap-off or supplied unassembled • A vast selection of power and data plates, including RCD options • Single or separate compartment bases for ease of data cabling • Rapid installation and fast ratchet mechanism which adjusts to floor finish thickness
access floor service outlet and slab mounted floor boxes empty boxes and accessory plates
2 compartment
Example
mm
366
mm
100 mm width plates
100 mm width plates
mm
mm
290
Empty boxes
230
230
mm 230
To configure boxes as required, select : 1. Box depth 2. Number of compartments required 3. Desired accessory plates
4 compartment
3 compartment
366
75 mm width plates
Single base – 75 mm depth
CR2001
CR011
CR4001
Single base – 85 mm depth (standard box)
CR2002
CR012
CR4002
Single base – 110 mm depth
CR2003
CR013
CR4003
Separate compartment base – 75 mm depth
CR2004
CR014
CR4004
Separate compartment base – 85 mm depth
CR2005
CR015
CR4005
Separate compartment base – 110 mm depth
CR2006
CR016
CR4006
Slab boxes Fix directly onto floor slab (supplied empty)
Accessory plates
1 compartment
2 compartment
3 compartment
CR5102
CR5202
CR5302
For 1, 2 and 3 compartment boxes
mm
4 compartment CR5402 For 4 compartment boxes
Blank plate
CR020
CR4100
2 gang switched socket outlet
CR022
CR4101
2 gang switched socket outlet, low noise / clean earth
CR023
CR4102
2 gang non-standard switched socket outlet
CR027
CR4103
2 gang unswitched socket outlet
CR029
CR4104
3 gang unswitched socket outlet
CR030
CR4105
3 gang unswitched socket outlet, low noise / clean earth
CR044
CR4118
2 gang RCD socket outlet
CR036
CR4111
2 gang RCD socket outlet, low noise / clean earth
CR043
CR4117
Punched plate for 2 x 1 gang accessories (60·3 mm fixing centres)
CR026
–
Punched plate for 2 gang accessories (120·6 mm fixing centres)
CR028
–
Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)
CR042
CR4115
2 x LJ2 accessory plate (50 mm fixing centres)
CR031
CR4106
4 x BNC connector plate
CR033
CR4108
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR024
CR4112
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR025
CR4113
24
024_Electrak v3.indd 24
20/12/2012 16:47
CF-EP0
access floor pre-wired service outlet boxes and accessory plates
Pre-wired service outlet boxes with Electrak tap-offs 1. Select power track tap-off and desired configuration 2. Select additional accessory plates (if required) Includes 1 x twin switched socket outlet
Includes 2 x twin switched socket outlet
Includes 1 x 2 gang RCD socket outlet
Includes 2 x 2 gang RCD socket outlet
DP1332 - 3 m
CR100
CR102
CR100R
CR102R
DP1532 - 5 m
CR101
CR103
CR101R
CR103R
JP2332 - 3 m
CR110
CR112
CR110R
CR112R
JP2532 - 5 m
CR111
CR113
CR111R
CR113R
YP5332 - 3 m
CR104
CR106
CR104R
CR106R
YP5532 - 5 m
CR105
CR107
CR105R
CR107R
3 compartment Electrak 24 - standard tap-off
230
Electrak 25 - low noise / clean earth tap-off
mm m 66 m
3
Electrak 28 - auxiliary earth tap-off
Additional plates for 3 compartment boxes Blank plate
CR020
2 x LJ2 accessory plate (50 mm fixing centres)
CR031
Punched plate for 2 x 1 gang accessories (60路3 mm fixing centres)
CR026
4 x BNC connector plate
CR033
Punched plate for 2 gang accessories (120路6 mm fixing centres)
CR028
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR024
Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)
CR042
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR025
Includes 1 x twin switched socket outlet
Includes 2 x twin switched socket outlet
Includes 1 x 2 gang RCD socket outlet
Includes 2 x 2 gang RCD socket outlet
Modular RCD protecting 2 x twin switched socket outlets and 1 spare compartment
DP1332 - 3 m
CR120
CR122
CR120R
CR122R
CR4402
DP1532 - 5 m
CR121
CR123
CR121R
CR123R
CR4403
JP2332 - 3 m
CR130
CR132
CR130R
CR132R
CR4412
JP2532 - 5 m
CR131
CR133
CR131R
CR133R
CR4413
YP5332 - 3 m
CR124
CR126
CR124R
CR126R
CR4406
YP5532 - 5 m
CR125
CR127
CR125R
CR127R
CR4407
4 compartment Electrak 24 - standard tap-off
Electrak 25 - low noise / clean earth tap-off 230 mm 366
mm
Electrak 28 - auxiliary earth tap-off
Additional plates for 4 compartment boxes Blank plate
CR4100
4 x BNC connector plate
CR4108
Angled punched plate for 4 x RJ45 sockets (37 mm x 22 mm cut-outs)
CR4115
4 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR4112
2 x LJ2 accessory plate (50 mm fixing centres)
CR4106
6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
CR4113
25
025_Electrak v4.indd 25
20/12/2012 16:49
access floor service outlet boxes
slab mounted floor boxes
empty boxes
empty boxes
CR5302
CR4002 3 compartment slab floor box shown with two twin switched socket outlets, punched data plate and a power track tap-off CR5102 picto loupe-65765j.eps
CR012
Selection chart (p. 24) Dimensions and technical information (p. 29) id and trim mouldings are precision engineered from hard wearing L durable ABS. The lid is reinforced with a galvanised mild steel plate Mounting frame and box base - 0路9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Grey mouldings. Alternative colours available to special order. Goosewing grey plates 2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring Supplied in parts or fully assembled and configured to customer specification Conform to IEC-61534-22
Pack
Cat. Nos.
2 compartment floor boxes Empty boxes
100 mm compartment widths
1 1 1 1 1 1
CR2001 CR2002 CR2003 CR2004 CR2005 CR2006
Single base - 75 mm depth ingle base - 85 mm depth (standard box) S Single base - 110 mm depth Separate compartment base - 75 mm depth Separate compartment base - 85 mm depth Separate compartment base - 110 mm depth
3 compartment floor boxes
Empty boxes 100 mm compartment widths
1 1 1 1 1 1
CR011 CR012 CR013 CR014 CR015 CR016
4 compartment floor boxes
Empty boxes 75 mm compartment widths
1 1 1 1 1 1
CR4001 CR4002 CR4003 CR4004 CR4005 CR4006
Single base - 75 mm depth ingle base - 85 mm depth (standard box) S Single base - 110 mm depth Separate compartment base - 75 mm depth Separate compartment base - 85 mm depth Separate compartment base - 110 mm depth
Electrak slab floor boxes are an ideal solution for underfloor power and data requirements Used in conjunction with Electrak floor grommets, slab boxes prevent unwanted access to power and data connections
Pack
Cat. Nos.
Slab floor boxes
1 1 1
75 mm compartment widths
Use plates from the 4 compartment floor box section (p. 24)
1
Fixes directly onto floor slab Fast and efficient installation with integrated fixing plates Wide range of power and data accessory plates Manufactured from 0路9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits 100 mm compartment widths
Use plates from the 1, 2 and 3 compartment floor box section (p. 24) CR5102 1 compartment slab floor box CR5202 2 compartment slab floor box CR5302 3 compartment slab floor box
CR5402 4 compartment slab floor box
Single base - 75 mm depth ingle base - 85 mm depth (standard box) S Single base - 110 mm depth Separate compartment base - 75 mm depth Separate compartment base - 85 mm depth Separate compartment base - 110 mm depth
Screed / edge trim boxes, and metal or lockable lids are available to order contact us on +44 (0) 845 600 6266
26
026_027_Electrak v4.indd 26
20/12/2012 13:04
access floor service outlet boxes accessory plates and ancillary items
picto loupe-65765j.eps
Selection chart (p. 24-25) Dimensions and technical information (p. 29) Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base - 0·9 mm thick galvanised steel Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Grey mouldings. Alternative colours available to special order. Goosewing grey plates 2, 3 and 4 compartment boxes are also available with separate individual compartment base units for convenient offsite pre-wiring Supplied in parts or fully assembled and configured to customer specification Conform to IEC-61534-22
Pack
Cat. Nos.
1 1 1 1 1 1
1 1 1
CR020 CR022 CR023 CR027 CR029 CR030 CR044 CR036 CR043 CR026
1
CR028
1
CR042
1 1 1 1
CR031 CR033 CR024 CR025
1, 2 and 3 compartment accessory plates
Pack
Cat. Nos.
100 mm width
Blank plate 2 gang switched socket outlet 2 gang switched socket outlet, low noise / clean earth 2 gang non-standard switched socket outlet 2 gang unswitched socket outlet 3 gang unswitched socket outlet 3 gang unswitched socket outlet, low noise / clean earth 2 gang RCD socket outlet 2 gang RCD socket outlet, low noise / clean earth Punched plate for 2 x 1 gang accessories (60·3 mm fixing centres) Punched plate for 2 gang accessories (120·6 mm fixing centres) Angled punched plate for 4 x RJ45 (37 mm x 22 mm cut-outs) 2 x LJ2 accessory plate (50 mm fixing centres) 4 x BNC connector plate 4 x Data / telecoms plate (37 mm x 22 mm cut-outs) 6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
1 1 1 1 1 1
1 1 1
CR4100 CR4101 CR4102 CR4103 CR4104 CR4105 CR4118 CR4111 CR4117 CR4115
1 1 1 1
CR4106 CR4108 CR4112 CR4113
1 1 10 10 50 1 1 1 1
CR0001 CR0003 CR0000 CR0010 CR0011 CR0012 CR0002 CR0004 CR0005
1
10 1
4 compartment accessory plates 75 mm compartment widths Blank plate 2 gang switched socket outlet 2 gang switched socket outlet, low noise / clean earth 2 gang non-standard switched socket outlet 2 gang unswitched socket outlet 3 gang unswitched socket outlet 3 gang unswitched socket outlet, low noise / clean earth 2 gang RCD socket outlet 2 gang RCD socket outlet, low noise / clean earth Angled punched plate for 4 x RJ45 (37 mm x 22 mm cut-outs) 2 x LJ2 accessory plate (50 mm fixing centres) 4 x BNC connector plate 4 x Data / telecoms plate (37 mm x 22 mm cut-outs) 6 x Data / telecoms plate (37 mm x 22 mm cut-outs)
Ancillary items for service outlet boxes
Floor tile cut-out template – 2 compartment Floor tile cut-out template – 3/4 compartment Cable outlet flap Cable routers Screws for accessory plates Pack of 5 keys for use with lockable floor boxes Lid – 2 compartment box Lid – 3/4 compartment box Mounting frame for vinyl floor. For 2 compartment box Replaces mounting frame attached to base CR0006 Mounting frame for vinyl floor. For 3/4 compartment box. Replaces mounting frame attached to base CR0007 Floor box lid handle CR0020 Metal lid and trim - replacement for 3 and 4 compartment boxes - powder coated grey
Electrak tap-offs (see p. 12-16)
27
026_027_Electrak v4.indd 27
20/12/2012 13:04
access floor pre-wired service outlet boxes
3 and 4 compartment
CR100
CR122
picto loupe-65765j.eps
Dimensions and technical information (p. 29) Electrak floor boxes can be supplied pre-wired to power track tap-offs with any variation of sockets, tap-offs, depth or other configuration
Pack
Cat. Nos.
1 1 1
CR100 CR101 CR110
1
1
1
3 compartment pre-wired boxes with 1 x TSSO
Pack
Cat. Nos.
100 mm compartment widths
1 1 1
CR120 CR121 CR130
1
1
4 compartment pre-wired boxes with 2 x TSSO
3 compartment pre-wired boxes with 2 x TSSO
75 mm compartment widths
CR102 CR103 CR112
1 1 1
CR122 CR123 CR132
1
1
Single base – 85 mm depth, pre-wired with : 3 m Electrak 24 standard tap-off Cat. No. DP1332 5 m Electrak 24 standard tap-off Cat. No. DP1532 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 CR111 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 CR104 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 CR105 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
1 1 1
1
1
1
100 mm compartment widths
Single base – 85 mm depth, pre-wired with : 3 m Electrak 24 standard tap-off Cat. No. DP1332 5 m Electrak 24 standard tap-off Cat. No. DP1532 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 CR113 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 CR106 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 CR107 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
1
1
4 compartment pre-wired boxes with 1 x TSSO 75 mm compartment widths
Single base – 85 mm depth, pre-wired with : 3 m Electrak 24 standard tap-off Cat. No. DP1332 5 m Electrak 24 standard tap-off Cat. No. DP1532 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 CR131 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 CR124 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 CR125 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
Single base – 85 mm depth, pre-wired with : 3 m Electrak 24 standard tap-off Cat. No. DP1332 5 m Electrak 24 standard tap-off Cat. No. DP1532 3 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2332 CR133 5 m Electrak 25 low noise / clean earth tap-off Cat. No. JP2532 CR126 3 m Electrak 28 auxiliary earth tap-off Cat. No. YP5332 CR127 5 m Electrak 28 auxiliary earth tap-off Cat. No. YP5532
Pre-wired floor boxes can be supplied with RCD rather than standard sockets. Add an R to the end of the part numbers for an RCD version. For example CR100R is a 3 compartment floor box with a twin RCD socket and a DP1332 tap-off
Also available : - pre-wired boxes with fused tap-offs - shallow or deep versions - separate compartment bases contact us on +44 (0) 845 600 6266
28
028_Electrak v3.indd 28
20/12/2012 17:03
access floor service outlet boxes with RCD protection
access floor service outlet boxes technical information
n Floor boxes
picto loupe-65765j.eps
Dimensions Lid can accommodate carpets up to 6 mm depth Accessory plates are 172 mm long, with 162 mm fixing centres Materials Lid and trim mouldings are precision engineered from hard wearing durable ABS. Lid is reinforced with a galvanised mild steel plate Mounting frame and box base – 0¡9 mm thick galvanised steel Floor service unit conforms to IEC-61534-22 Wiring Each compartment has 2 entries for 20 mm and 2 entries for 25 mm flexible conduits Colour Grey mouldings. Alternative colours available to special order Goosewing grey plates
CR4401
Selection chart (p. 24-25) Dimensions and technical information (opposite)
Dimensions from top of floor tile into floor void
Electrak floor boxes are available with various RCD protection options and can be supplied pre-wired to power track tap-offs C
Pack
Cat. Nos. Floor
boxes with RCD protection and 2 x TSSO
A B
Boxes contain 1 spare 75 mm width compartment
1 1
CR4400 Includes standard sockets CR4401 Includes low noise sockets
Pre-wired RCD protected floor boxes
Boxes contain RCD and 2 x TSSO with 1 spare 75 mm compartment
1 1 1 1
CR4402 CR4403 CR4412 CR4413
Pre-wired Pre-wired Pre-wired Pre-wired
with with with with
Cat. Cat. Cat. Cat.
No. No. No. No.
DP1332 tap-off DP1532 tap-off JP2332 tap-off JP2532 tap-off
A (mm)
B Accessory box depth (mm)
C Underside lid to top of accessory (plug clearance) (mm)
75 85 110
35 45 45
35 35 60
n To install box Cut hole in raised floor tile, lower complete box into aperture and push firmly down
Floor tile cut-out dimensions 2 compartment : 263 mm x 203 mm(1) 3 and 4 compartment : 340 mm x 203 mm(1) Floor cut-out aperture is the same for single base or separate compartment base To fit carpet : Detach lid and trim assembly by lifting the blue locking handles and lifting out. Cut and fit carpet. Push lid and trim assembly back into place
(1) The aperture dimension 203 mm has a fixing tolerance between 203 to 205 mm
29
029_Electrak v2.indd 29
20/12/2012 18:31
Floor grommets...
perfectly balancing capacity and size
30
Removable inlay for optional carpet fitting
Cable flap allows permanent connection of services
Flat mounted RCD socket
NEW 169mm diameter provides the perfect balance between size and capacity
Spring loaded screws for rapid installation
Available pre-wired to power track tap-offs
31
Acccess grommets Electrak’s simple to install access grommets allow cables and conduit to link between underfloor power and desk power systems • Ranging from 144mm to 232mm in diameter • NEW 169mm diameter grommet can accommodate up to 3 x 32mm conduits - perfectly balancing capacity and size • Push-fit lid with optional screw fixing to prevent unauthorised access
Power and data grommets Electrak’s new cleaner’s grommets are the latest addition to its power and data grommets range. Within their 169mm diameter, the grommet can now house a flat RCD socket and provide ample space for the user to plug in or unplug equipment. • NEW cleaner’s grommet with flat mounted RCD socket or standard socket options • Push-fit lid with cable flap feature • Spring loaded screws for rapid installation • Available pre-wired to power track tap-offs
floor grommets access / power and data
EG0030
EG0010
EG0040
picto loupe-65765j.eps
EG0045
Dimensions and technical information (p. 33)
Pack
Cat. Nos.
1
1
EG0055 232 mm Ø – cut-out size 215 mm Ø High capacity grommet Recommended for installation in light traffic areas
NEW
1
1
Quick fit installation Precision engineered from hard wearing durable ABS Grey mouldings. Other colours available to special order Grommets conform to IEC-61534-22 Simply secured by pushing down the spring-loaded screws and rotating a quarter turn
EG0030 169 mm Ø – cut-out size 152 mm Ø Allows power, data and flexible conduit up to 32 mm NEW to pass through raised access floor Lid can be locked with screw (included) Maximum number of conduits : 9 x 20 mm Ø 5 x 25 mm Ø 3 x 32 mm Ø
1
Pack
Cat. Nos.
NE W
EG0010 144 mm Ø – cut-out size 127 mm Ø Can accomodate all cable types or three metal conduits up to a 20 mm Ø or 25 mm without foam
Plastic access grommets
Aluminium access grommet ody – cast aluminium B Lid – injection moulded plastic Nylon 66 with neoprene cable gasket Secured by quarter-turn fasteners Floor depth 25 to 55 mm Access grommet depth 60 mm (95 mm when back box included)
EG0015 144 mm Ø – cut-out size 127 mm Ø Allows power, data and flexible conduit up to 25 mm to pass through raised access floor
Plastic power and data grommets 169 mm Ø – cut-out size 152 mm Ø Quick fit installation Precision engineered from hard wearing durable ABS Grey mouldings. Other colours available to special order. Conform to IEC-61534-22 Removable carpet recess Cable flap feature so grommet lid can be closed while in use Simply secured by pushing down the spring loaded screws and rotating a quarter turn
1
EG0040 13 A power grommet Supplied complete with 13 A unswitched socket
1
EG0045 RCD power grommet Supplied complete with 13 A RCD socket
1
EG0051 13 A power/data grommet Supplied complete with 13 A socket and 1 x 37 x 22 mm cut-out
1
EG0052 Data grommet Supplied complete with data plate 2 x 37 x 22 mm cut-out
1 1 1 1
NEW EG0041 EG0042 EG0043 EG0044
Cleaners socket version DP1332 - 3 m unfused DP1532 - 5 m unfused DP1313 - 3 m 13 A fused DP1513 - 5 m 13 A fused
1 1 1 1
EG0046 EG0047 EG0048 EG0049
RCD socket version P1332 - 3 m unfused D DP1532 - 5 m unfused DP1313 - 3 m 13 A fused DP1513 - 5 m 13 A fused
Pre-wired power grommets 169 mm Ø – cut-out size 152 mm Ø
Aluminium power grommet
EG0025 13 A power grommet Supplied complete with 13 A NE W unswitched socket
32
032_Electrak v2.indd 32
20/12/2012 18:33
floor grommets technical information
144 mm Ø
55 mm
n 144 mm Ø plastic floor grommet
n To install plastic floor grommet
Dimensions 144 mm grommet EG0010
A
B
Lift handle and pull to remove lid
Push grommet into raised floor tile aperture Push down spring loaded screws and rotate quarter turn to secure Ensure wings are located under floor panel For honeycombed floor panels one wing should face downwards and one wing should face upwards
C
D
E
Slide lid into lug holes
(1) Push down lid to close (2) If grommet is not in use, replace cable access insert
144 mm Ø
55 mm 90
Recommended hole cutter is a 5"/127 mm hole saw blade
125 mm min 127 mm min
Wing
Floor panel cut-out diameter
90 mm
n 169 mm Ø plastic floor grommets Access grommet
125 mm min 127 mm min
Recommended hole
Cat.cutter No.isEG0030 a 5"/127 mm hole saw blade
55
Floor panel cut-out diameter
1
Ø148
2
Ø 169
Power grommet 60
102
Cable access insert Drop cable access insert into housing opening
Ø148
Ø 169
90
n 144 mm Ø aluminium grommets
Recommended hole cutter is a 6’’/152 mm hole saw blade
Access grommet Cat. No. EG0015
n 232 mm Ø plastic floor grommet 60
Dimensions Large quick fit grommet Cat. No. EG0055
40
232 mm Ø
60 95 90
58 mm
13 A power grommet
144
Cat. No. EG0025 213 mm min 215 mm max
40
60 95
Floor panel cut-out diameter Recommended hole cutter is a adjustable hole saw blade with Ø range of 40 mm - 300 mm
144
Recommended hole cutter is a 5’’/127 mm hole saw blade
33
033_Electrak v3.indd 33
20/12/2012 17:15
Intersoc-R ... fast, reliable, TM
adaptable modular desk power
34
complete solutions for DEMANDING ENVIRONMENTS Intersoc-R is a modular desk power system designed to meet the demands of modern workplaces for faster and more adaptable solutions.
Designed with speed of installation and flexibility in mind, Intersoc-R’s modular configuration enables thousands of different combinations to be made - providing solutions for every installation requirement. • Modular system - rapid configuration and easy workstation relocation • Push-fit connection - modules can simply be disconnected and additional modules inserted • Busbar interconnection - no need for wiring • Easily adapted to meet the changing demands of the workplace
35
36
THE NEXT GENERATION OF POWER DISTRIBUTION Available in standard and clean earth versions, with fixed or rotatable socket options and a safe shuttered electrical connection, Intersoc-R is the next generation of power distribution...
• Simple push-fit, module connection with auto-lock mechanism creates robust joints and makes installation quicker and easier • 32 A system with safe shuttered electrical connections for additional safety, meets the requirements of BS 7671 : 2008 (including section 543.7) • MCB, RCD and RCBO modules, with reversible hinged covers, provide a full range of circuit protection options • 2, 3 or 4 gang British standard socket modules with fixed or rotatable, fused or unfused (BS 6396) sockets options - all the options you need to meet the requirements of any installation • 8 international socket options make Intersoc-R ideal for installations across the globe • Outgoing connections: flexible interlink or end cap with ST or GST options
37
DESK MODULES Intersoc desktop units provide easy access to power and data points. Choose from: • Horizontal or vertical orientation • A choice of electrical connections: BS 1362 plug, GST connector or interlinked to the Intersoc-R underdesk system • A range of socket options: angled to 45º or 90º, fused / unfused • RJ45 and USB outlets available
NEW
Intersoc-RTM desk modules electrical supply
IAB301A
IAB002A IAB660B IAB312A
picto loupe-65765j.eps
IAB610BB
Dimensions and technical information (p. 44-47) Intersoc-R features fast modular connection with push-fit auto lock mechanism, safe shuttered electrical connections and a robustly designed rigid joint between modules Available in standard and clean earth versions, conforms to BS 5733 and the relevant parts of BS 1363 part 2. Manufactured in an approved ISO 9001 : 2008 facility. Meets the requirements of BS 7671 : 2008 for high integrity earthing (section 543·7)
Pack
Cat. Nos.
1 1 1 1
1 1 1 1
1 1 1 1
1 1
1 1
1 1 1 1
1 1 1 1
32 A pre-wired feed modules Standard earth tap-offs (E24 - White tap-off)
IAB311A 3 m unfused metal tap-off Cat. No. DP1332 IAB312A 5 m unfused metal tap-off Cat. No. DP1532 IAB315A 3 m 13 A fused 543·7 metal tap-off Cat. No. DP1327 IAB316A 5 m 13 A fused 543·7 metal tap-off Cat. No. DP1527
Low noise / clean earth tap-offs (E25 - Green tap-off)
IAC311A 3 m unfused metal tap-off Cat. No. JP2332 IAC312A 5 m unfused metal tap-off Cat. No. JP2532 IAC315A 3 m 13 A fused 543·7 metal tap-off Cat. No. JP2327 IAC316A 5 m 13 A fused 543·7 metal tap-off Cat. No. JP2527
Auxiliary earth tap-offs (E28 - Red tap-off)
IAF311A 3 m unfused metal tap-off Cat. No. YP5332 IAF312A 5 m unfused metal tap-off Cat. No. YP5532 IAF315A 3 m 13 A fused 543·7 metal tap-off Cat. No. YP5327 IAF316A 5 m 13 A fused 543·7 metal tap-off Cat. No. YP5527
Pack
1 1 1
1
1 1
Cat. Nos.
6 A feed modules pre-wired to 13 A fused 1 plug
IAB002A With 2 m 1·5 mm2 cable IAB003A With 3 m 1·5 mm2 cable IAB005A With 5 m 1·5 mm2 cable
16 A rewirable feed modules
IAB201A Rewirable feed module (for cable)
6 A feed units with in-built GST 1 connector
IAB660B Compact feed module with male GST connector IAB201B Feed module with male GST and earth bond lead
16 A pre-wired connection leads
13 A fused plug pre-wired to GST connector
32 A re-wirable feed modules
1 1 1
IAB301A Standard earth (for flexible conduit) IAC301A Low noise (for flexible conduit)
1 1 1
2 A feed units with in-built Neutrik 3 connectors
IAB301E Standard earth IAC301E Low noise
32 A tap-offs pre-wired to Neutrik connectors
1
Standard earth tap-offs (E24)
IAB311E 3 m unfused metal tap-off Cat. No. DP1332 IAB312E 5 m unfused metal tap-off Cat. No. DP1532 IAB315E 3 m 13 A fused 543·7 metal tap-off Cat. No. DP1327 IAB316E 5 m 13 A fused 543·7 metal tap-off Cat. No. DP1527
Low noise / clean earth tap-offs (E25)
IAC311E 3 m unfused metal tap-off Cat. No. JP2332 IAC312E 5 m unfused metal tap-off Cat. No. JP2532 IAC315E 3 m 13 A fused 543·7 metal tap-off Cat. No. JP2327 IAC316E 5 m 13 A fused 543·7 metal tap-off Cat. No. JP2527
1
1
1
1
1
1
IAB002B With 2 m 1·5 mm2 cable IAB003B With 3 m 1·5 mm2 cable IAB005B With 5 m 1·5 mm2 cable
GST to GST connection leads
IAB610BB 1 m length IAB620BB 2 m length IAB630BB 3 m length
I nternational plugs pre-wired to GST connector
Schuko
IAB002NB With 2 m 1·5 mm2 cable
French/Belgium
IAB002UB With 2 m 1·5 mm2 cable
5 A Indian
IAB002PB With 2 m 1·5 mm2 cable
15 A South African
IAB002QB With 2 m 1·5 mm2 cable
Australian/Chinese
IAB002RB With 2 m 1·5 mm2 cable
15 A USA
IAB002SB With 2 m 1·5 mm2 cable
20 A USA
IAB002TB With 2 m 1·5 mm2 cable
38
038_039_Electrak v2.indd 38
20/12/2012 18:41
Intersoc-RTM desk modules
NEW
protection, BS sockets, end caps and interlinks
IAC502R
IAB402A
IAB533F
IAB450A
IAZ001A
IAB703A
IAB600B
IAB610B
IAB504R
picto loupe-65765j.eps
Dimensions and technical information (p. 44-47) The BS version is available with fixed or rotatable sockets. Individually fused sockets are available to meet the requirements of BS 6396 : 2008 (5 x 20 mm anti-surge ceramic fuses) A wide range of interconnection solutions are available. When 16 A cabling interconnection is used with 32 A under desk solutions, suitable de-rating protection devices must be incorporated to protect the cables All protection and switching modules, end caps and interlinks are universally compatible with standard and clean earth / low noise systems
Pack
1 1 1 1 1 1 1 1 1 1 1 1
1 1
1 1
1 1
1 1
Cat. Nos.
Protection and switching modules
IAB401A With 13 A fuse IAB402A With 13 A fuse and sw/neon IAB403A With 13 A fuse and neon IAB404A 32 A max. single isolation module IAB405A With 30 mA RCD IAB408A With neon indicator IAB420A With 16 A MCB IAB430A With 20 A MCB IAB440A With 32 A MCB IAB450A With 16 A RCBO IAB460A With 20 A RCBO IAB470A With 32 A RCBO
1 1
1 1
2 gang unfused
1
2 gang individually fused
3 gang unfused
3 gang individually fused
1 1
4 gang unfused
1 1
Socket modules – low noise / clean earth (green sockets)
2 gang unfused
1 1
1 1
IAB504F Fixed sockets IAB504R Rotatable sockets 4 gang individually fused
IAB534F 3·15 A – fixed sockets IAB534R 3·15 A – rotatable sockets
IAC502F Fixed sockets IAC502R Rotatable sockets
1 1
1 1
IAB533F 3·15 A – fixed sockets IAB533R 3·15 A – rotatable sockets
IAB503F Fixed sockets IAB503R Rotatable sockets
IAB532F 3·15 A – fixed sockets IAB532R 3·15 A – rotatable sockets
Pack
Socket modules – standard (grey sockets)
IAB502F Fixed sockets IAB502R Rotatable sockets
2 gang individually fused
IAC532F 3·15 A – fixed sockets IAC532R 3·15 A – rotatable sockets
Cat. Nos.
Socket modules – low noise / clean earth (green sockets) (continued) 3 gang unfused
IAC503F Fixed sockets IAC503R Rotatable sockets
3 gang individually fused
IAC533F 3·15 A – fixed sockets IAC533R 3·15 A – rotatable sockets
4 gang unfused
IAC504F Fixed sockets IAC504R Rotatable sockets
4 gang individually fused
IAC534F 3·15 A – fixed sockets IAC534R 3·15 A – rotatable
End cap
IAZ001A Blank end cap
Intersoc to intersoc pre-wired interconnection
16 A
1 1 1 1 1 1
1 1 1 1 1 1
1 1
1 1 1
IAB603A 0·3 m length IAB605A 0·5 m length IAB610A 1 m length IAB620A 2 m length IAB630A 3 m length IAB650A 5 m length
32 A
IAB703A 0·3 m length IAB705A 0·5 m length IAB710A 1 m length IAB720A 2 m length IAB730A 3 m length IAB750A 5 m length
Power out end caps 16 A
Without flex
IAB600B End cap with female GST connector IAB600C End cap with female ST connector
With flex to female GST connector
IAB610B 1 m length IAB620B 2 m length IAB630B 3 m length
39
038_039_Electrak v2.indd 39
20/12/2012 17:31
Intersoc® international range international socket options
IAB5N4A
IAB5P4A
IAC5P2A
IAF5N2A
picto loupe-65765j.eps
Dimensions and technical information (p. 44-47) The Intersoc 32 A under-desk range is a complete modular power system. Intersoc offers a wide range of international socket options. The Intersoc modular system features safe shuttered electrical connections and a robustly designed rigid joint between modules. All modules connect with single push-fit action and auto lock
Pack
Cat. Nos.
1 1 1 1 1 1 1 1
4 gang – grey socket outlets
2 gang – red socket outlets
IAF5N2A 90° angled sockets IAF5N2B 45° angled sockets
2 gang – grey socket outlets
IAB5N4A 90° angled sockets IAB5N4B 45° angled sockets
IAB5N2A 90° angled sockets IAB5N2B 45° angled sockets
Schuko socket modules
4 gang – red socket outlets
IAF5N4A 90° angled sockets IAF5N4B 45° angled sockets
Pack
1 1
Cat. Nos.
1 1 1 1 1 1
2 gang – green socket outlets
IAC5P2A 90° angled sockets IAC5P2B 45° angled sockets
4 gang – grey socket outlets
IAB5P4A 90° angled sockets IAB5P4B 45° angled sockets
2 gang – grey socket outlets
IAB5P2A 90° angled sockets IAB5P2B 45° angled sockets
5 A Indian socket modules
4 gang – green socket outlets
IAC5P4A 90° angled sockets IAC5P4B 45° angled sockets
French/Belgium socket modules
15 A South African socket modules
2 gang – grey socket outlets
2 gang – grey socket outlets
1 1
IAB5U2A 90° angled sockets IAB5U2B 45° angled sockets
1 1
1 1 1 1
2 gang – red socket outlets
IAF5U2A 90° angled sockets IAF5U2B 45° angled sockets
4 gang – grey socket outlets
IAB5U4A 90° angled sockets IAB5U4B 45° angled sockets
4 gang – red socket outlets
IAF5U4A 90° angled sockets IAF5U4B 45° angled sockets
1 1
IAB5Q2A 90° angled sockets IAB5Q2B 45° angled sockets
1 1
1 1 1 1
2 gang – green socket outlets
IAC5Q2A 90° angled sockets IAC5Q2B 45° angled sockets
4 gang – grey socket outlets
IAB5Q4A 90° angled sockets IAB5Q4B 45° angled sockets
4 gang – green socket outlets
IAC5Q4A 90° angled sockets IAC5Q4B 45° angled sockets
40
040_Electrak v2.indd 40
20/12/2012 18:46
Intersoc® international range international socket options (continued)
IAB5R4A
IAB5S4A
IAC5R2A
IAC5S2A
picto loupe-65765j.eps
Dimensions and technical information (p. 44-47) The Intersoc 32 A under-desk range is a complete modular power system. Intersoc offers a wide range of international socket options. The Intersoc modular system features safe shuttered electrical connections and a robustly designed rigid joint between modules. All modules connect with single push-fit action and auto lock
Pack
1 1
1 1
1 1
1 1
Cat. Nos.
Australian/Chinese socket modules
2 gang – grey socket outlets
1 1
IAB5R2A 90° angled sockets IAB5R2B 45° angled sockets
4 gang – grey socket outlets
IAB5R4A 90° angled sockets IAB5R4B 45° angled sockets
2 gang – green socket outlets
IAC5R2A 90° angled sockets IAC5R2B 45° angled sockets
4 gang – green socket outlets
IAC5R4A 90° angled sockets IAC5R4B 45° angled sockets
Pack
1 1
1 1
1 1
1 1
1 1
1 1
1 1
Cat. Nos.
15 A USA socket modules 2 gang – grey socket outlets
IAB5S2A 90° angled sockets IAB5S2B 45° angled sockets
4 gang – grey socket outlets
IAB5S4A 90° angled sockets IAB5S4B 45° angled sockets
2 gang – green socket outlets
IAC5S2A 90° angled sockets IAC5S2B 45° angled sockets
4 gang – green socket outlets
IAC5S4A 90° angled sockets IAC5S4B 45° angled sockets
20 A USA socket modules
2 gang – grey socket outlets
IAB5T2A 90° angled sockets IAB5T2B 45° angled sockets
4 gang – grey socket outlets
IAB5T4A 90° angled sockets IAB5T4B 45° angled sockets
2 gang – green socket outlets
IAC5T2A 90° angled sockets IAC5T2B 45° angled sockets
4 gang – green socket outlets
IAC5T4A 90° angled sockets IAC5T4B 45° angled sockets
41
041_Electrak v2.indd 41
20/12/2012 17:38
Intersoc® HDU and VDU modules
horizontal and vertical desktop units can be configured to bespoke customer requirements
A Cat. No. for a bespoke unit can be created by following the flow table below : Horizontal or vertical orientation Cat. No. digit 1
H V
Horizontal desk unit Vertical desk unit
A B D
BS1363 plug GST connector Flexible interlink to modular Intersoc system
Electrical connection Cat. No. digit 2
Length of electrical connection cable Cat. No. digit 3
1 2 3 5
1 m connection lead 2 m connection lead 3 m connection lead 5 m connection lead
4 9
Sockets at 45º Sockets at 90º
Angle of socket outlets Cat. No. digit 4
Individual fusing of socket outlets Cat. No. digit 5
0 3 5
Unfused Sockets individualy fused at 3·15 A Sockets individualy fused at 5 A
2 3 4
2 electrical sockets 3 electrical sockets 4 electrical sockets
A B C
No switching Single master switch Sockets individually switched
A B C D E F G H
Unit without data With 1 x RJ45 outlet and 3 m cat 5 lead With 2 x RJ45 outlets and 3 m cat 5 leads With 1 x RJ45 outlet and 3 m cat 6 lead With 2 x RJ45 outlets and 3 m cat 6 leads With 1 x USB outlet and 3 m lead With 2 x USB outlets and 3 m leads With 4 x USB outlets and 3 m leads
Number of sockets Cat. No. digit 6 Switching requirements Cat. No. digit 7 Data Cat. No. digit 8
For example an HD1932BG would have the following specification : H = Horizontal desk unit D = Flexible interlink to modular Intersoc system 1 = 1 m connection lead 9 = Sockets at 90º 3 = Sockets individualy fused at 3.15 A 2 = 2 electrical sockets B = Single master switch G = With 2 x USB outlets and 3 m leads NOTE : Fixings must be ordered separately
42
042_043_Electrak v3.indd 42
20/12/2012 17:52
Intersoc® HDU and VDU modules horizontal and vertical desktop units
Horizontal on-desk unit Vertical on-desk unit picto loupe-65765j.eps
Dimensions and technical information (p. 44-45) Desktop units offer power and data solutions with a range of mounting options to compliment your furniture arrangements All units are housed in an aluminium extrusion and are available in either horizontal or vertical orientation Any combination of socket outlets and other services can be integrated into the aluminium housing to suit individual customer requirements including switching of individual sockets
Pack
Cat. Nos.
1 1
1
1 1
1 1
1
1 1
16 A horizontal desktop units (HDU)
Pack
Cat. Nos.
ll units are supplied with sockets angled at 90º A Where data is offered, units come complete with 3 m data leads & RJ45 plugs
1 m power lead – BS 1363 13 A fused plug
1 1
1
1 1
HA1952AA 2 sockets individually fused at 5 A HA1952AB 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet HA1952AC 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets HA1953AA 3 sockets individually fused at 5 A HA1954AA 4 sockets individually fused at 5 A
3 m power lead – BS 1363 13 A fused plug
HA3952AA 2 sockets individually fused at 5 A HA3952AB 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet HA3952AC 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets HA3953AA 3 sockets individually fused at 5 A HA3954AA 4 sockets individually fused at 5 A
1 1
1
1 1
2
10
1 m power lead – male GST connector
1 1
1
1 1
16 A vertical desktop units (VDU) ll units are supplied with sockets angled at 45º A Where data is offered, units come complete with 3 m data leads & RJ45 plugs 1 m power lead – BS 1363 13 A fused plug
VA1452AA 2 sockets individually fused at 5 A VA1452AB 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet VA1452AC 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets VA1453AA 3 sockets individually fused at 5 A VA1454AA 4 sockets individually fused at 5 A
3 m power lead – BS 1363 13 A fused plug
VA3452AA 2 sockets individually fused at 5 A VA3452AB 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet VA3452AC 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets VA3453AA 3 sockets individually fused at 5 A VA3454AA 4 sockets individually fused at 5 A
1 1
1
1 1
Fixings
Fixings
H001
Horizontal desktop unit fixing clamp
2
V001
Vertical desktop unit fixing clamp
H002
Desktop adhesive strip
HB1932AA 2 sockets individually fused at 3·15 A HB1932AB 2 sockets individually fused at 3·15 A + 1 x RJ45 CAT 5e data outlet HB1932AC 2 sockets individually fused at 3·15 A + 2 x RJ45 CAT 5e data outlets HB1933AA 3 sockets individually fused at 3·15 A HB1934AA 4 sockets individually fused at 3·15 A
1 m power lead – male GST connector
VB1432AA 2 sockets individually fused at 3·15 A VB1432AB 2 sockets individually fused at 3·15 A + 1 x RJ45 CAT 5e data outlet VB1432AC 2 sockets individually fused at 3·15 A + 2 x RJ45 CAT 5e data outlets VB1433AA 3 sockets individually fused at 3·15 A VB1434AA 4 sockets individually fused at 3·15 A
Any combination of socket and service outlets can be configured on request (eg USB, IBM, Co-axial, SGVA, RJ45 etc.) contact us on +44 (0) 845 600 6266
43
042_043_Electrak v3.indd 43
20/12/2012 18:48
Rewirable GST 3 Blank socket module 3 socket module interconnect interconnect End view male male end cap TM End view 37·9
End view
37·9 modules Intersoc-R under-desk and Intersoc® desktop
technical information
Rewirable GST Rewirable GST Rewirable GST interconnect interconnect Blank interconnect interconnect Blank interconnect interconnect Blank male male end cap male 2module socket in-feed module socket in-feed module male end cap 2 socket in-feed 4 67 socket in-feed4module 50 23 60 male male end cap n-feed module 4 socket in-feed module n Under-desk dimensions (mm) Rewirable GST Rewirable GST interconnect interconnect Blank interconne interconnect 60 2 Blank socket in-feed module 4 Rewirable male end cap male end cap et in-feed module GST 4 socket in-feed module male male 2 socket in-feed module 4GST socket in-feedRewirable module interconnect interconnect Compact and interconnect interconnect Blank feed unit female female Feed unit male male end cap -feed module GST 60 37·9
214·5
291·5
291·5
60
214·5
291·5
60
60
411·5
411·5
411·5
50 67
50 23 67
23 50
23
67
GST Rewirable291·5 Rewirable GST 50 50interconnect 67 12 Rewirable 67interconnect GST interconnect interconnect interconnectfemale interconnectfemale female 2 socket module 4 socket module female 2 socket module 4 socket module 75 110·5 411·5 50 67 12 female female 2End socket 4 socket module viewmodule End view Rewirable GST Rewirable GST interconnect interconnect interconne interconnect 2 socket mod 60 60 (1) (1) Fixed – Rotatable – (1) Rewirable GST 3 socket module female female 2 socket module 43socket module female female 2 socket module 4 socket module socket module 60 32 end view end view End view End view End view interconnect interconnect w End view female female 4 socket module 60 291·5
60
411·5
291·5
60
60
Interconnection 32
156·5
156·5
60
156·5
411·5
12
276·5
276·5
60156·5
75
214·5 272·5
156·5272·5 214·5
(1) Dimensions only apply to BS sockets and not the international range 272·5
75
37·9
276·5
75
75110·5 37·9
32 110·5
60 110·5
60 75
110·5
156
60
75
110·5
110·5
GST interconnect male
Interconnection Interconnection Blank 77·5 (1) MCB, RCD protection module Protection module MCB, RCD protection module Protection module Interconnection socket in-feed in-feed module 4 socket in-feed module end cap 2 socket in-feed module 42 socket module D protection module Protection module
0
50
60
60
MCB,60RCD protection module module Protection 60 Interconnection
RCD protection module Protection module 174·5
60 (1) 84·5 mm depth
174·5
174·5
60
Interconnection Protection module
6060
50 77·5 60
50
115·5
291·5 115·5
Interconnection MCB, RCD protection module
60
291·5 50 411·5
115·5
60 174·5 n Desktop range dimensions (mm)
2115·5 socket unit
115·5 50
End view
218
50
77·5
2 socket module 2 socket module socket module 2 socket 4and 1 RJ45 unit End view 293
77·5
174·5
60
32
40
156·5 60
60
50
12
GST interconnect 4 socket module female
115·5
60
32
411·5
77·5
50 174·5
77·5
77·5
156·5 272·5
272·5 75
100 40
100
40
2100 socket and 2 RJ45 unit
3 socket unit
348
293
40
60
60
40
Interconnection Protection module
MCB, RCD protection module Protection module
MCB, RCD protection module
100
100 174·5
174·5
4 socket unit
100
60
60
115·5
40 50 115·5
100
Vertical
Horizontal 368
100
40
40 40 100
100
100
40
100 40
100
All dimensions (mm) are nominal 40
44
044_047_Electrak v2.indd 44
100
20/12/2012 18:50
n Under-desk testing and accreditation
n Under-desk and desktop British Standards BS 6396 : 2008 Electrical Systems in Office Furniture and Educational Furniture Specification BS 7671 : 2008 incorporating amendment No. 1 : 2011. Requirements for Electrical Installation (IET Wiring Regulations 17th Edition) Electricity at Work Regulations 1989
Conforms to BS 5733 : 1995 incorporating amendment No. 1 and corrigendum No. 1 Conforms to the relevant parts of BS 1363 part 2 Manufactured within an approved ISO 9001 : 2008 facility Quality assurance certificate No. 2029
up to 32 A 250 V ~ 50/60 Hz
Conductor resistance at 20°C Fixed 2 socket module 4 socket module
0·8 mΩ 1·6 mΩ
For compliance with this standard, socket outlet configurations of up to 4 outlets should be individually fused at 5 A and up to 6 outlets individually fused at 3·15 A Rotatable 0·9 mΩ 1·7 mΩ
1·5 m V/A 3·0 m V/A 4·0 m V/A
(depending on device)
In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2
Total number of Individually fused sockets at 2, 3 or 4 sockets 5A 5 or 6 sockets 3·15 A Meets the requirements of BS 7671 : 2008 (2011) (17th Edition) The Health and Safety Executive states that installations which conform to the standards laid down in BS 7671 : 2008 (2011) are regarded by the HSE as likely to achieve conformity with the relevant parts of the Electricity at Work Regulations 1989
4·0 m V/A 29 m V/A/m 2·0 m V/A 11 m V/A/m
Special note should be taken of regulation 543·7 within BS 7671 : 2008 - Earthing requirements for the installation of equipment having high protective conductor currents Regulation 543·7 has particular importance when there is a requirement for a quantity of information technology equipment being supplied from a final circuit in a location where the sum of their protective currents exceeds 10 mA in normal use. Due to current in the protective conductor arising from the use of IT equipment, there is a requirement to provide mechanically protected 4 mm2 conductor (543·7·1·103 (ii)). Intersoc achieves this when wired in accordance with the installation sheets by providing mechanically protected 5 mm2 protective conductors within the product
2·0 m V/A 29 m V/A/m 11 m V/A/m
Earth fault loop impedance 2 socket module 4 socket module Protection module
In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2
1·5 mΩ 3·0 mΩ 4·0 mΩ
Material specification Under desk : Module housing Socket outlets Busbars Other metalwork On desk : Module housing Module fascia Socket outlets End caps
(depending on device)
2·0 mΩ 29 mΩ/m 2·0 mΩ 11 mΩ/m 4·0 m V/A 29 mΩ/m 11 mΩ/m
Mechanical data Number of conductors Busbar conductor cross-sectional area 16 A rewirable in-feed terminal capacity 32 A rewirable in-feed terminal capacity
A note on individual socket fusing – BS 6396 Compliance : The standard requires individual socket fusing (as per the table below)
Volt drop Live and neutral 2 socket module 4 socket module Protection module
Below is a brief outline of the main criteria within the standards : BS 6396 : 2008 was published with regard to the use of electrical equipment within general office and educational furniture. This standard sets out in its scope the use and testing of electrical socket outlets and associated wiring when used together with a 13 A BS 1363 fused plug for mains supply and makes provision for the routing of cables through furniture
Electrical test data Rated current Rated voltage Frequency
Health & Safety Legislation
Heat resistant ABS polycarbonate high conductivity copper CW004A (C101) phosphor bronze CW451K (PB102), CW452K (PB103) brass CW507L (CZ107), CW508L (CZ108) high conductivity copper CW004A (C101)(1) aluminium flame retardant ABS polycarbonate flame retardant ABS
(1) European grades with nearest British Standard shown in brackets
3 5 mm2 10 mm2 10 mm2
45
044_047_Electrak v2.indd 45
20/12/2012 18:11
Intersoc-RTM under-desk modules installation and configuration
n Installation To connect and disconnect Intersoc modules
1. Connection / disconnection to be made by a competent person 2. Before connecting modules ensure they are the correct way up and in line 3. Push modules together one at a time 4. Modules self-lock when fully pushed together 5. To disconnect modules slide green latch to unlock module and pull apart 6. Always end module run with blank end cap or interconnect
Module self-locking latch
Underside of modules shown
To fix modules to surface 1. Insert through all fixing holes no. 8 pozi-pan screw or M4 bolt to required length 2. Tighten screw / bolt down to mounting surface
Slide green latch
Blank end cap
2 socket module
16 A 4 socket in-feed module
46
044_047_Electrak v2.indd 46
20/12/2012 18:12
n Product configuration
1. Select the type of distribution system - standard, or low noise / clean earth 2. Select the means of powering the system - cable or power track tap-off 3. Select the type of in-feed module to match the cable capacity - 16 A or 32 A 4. Select the means of protection 5. Select the number of socket modules from the 2, 3 or 4 gang range (individually fused or unfused) 6. Select fixed or rotatable sockets 7. Select the interconnection units if required 8. Finish system with the end cap (All modules push fit and lock together on-site or can be factory assembled to customer requirement)
iiiiiil
Floor grommet
llllllllllllllllllllllllll llllllll lllllllllllllll Underfloor power track
1
2
l l ll ll l
lllll 32 A in-feed connected to tap-off and left underfloor until required
l ll l
l l ll
Tap-off
llll l
lllllllllllllllll
lllllll
Raised floor
l l ll l ll ll l
l ll l
In-feed and power module push together and lock with cam lock lever
Tap-off and in-feed pulled through floor grommet after testing and when required
47
044_047_Electrak v2.indd 47
20/12/2012 18:12
Contact details Quotations and Technical Support: The Power Distribution Division of Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 845 600 6266 Fax: +44 (0) 845 600 6760 E-mail: powersales.uk@legrand.co.uk Customer Services: The Power Distribution Division of Legrand Electric Ltd. No. 1 Industrial Estate Medomsley Road, Consett, County Durham, DH8 6SR Tel: +44 (0) 845 600 6266 Fax: +44 (0) 845 600 6366 E-mail: powersales.uk@legrand.co.uk Accounts: Legrand Electric Ltd. Great King Street North, Birmingham, B19 2LF Tel: +44 (0) 870 608 9000 Fax: +44 (0) 870 608 9004
Head office (UK and Ireland): Legrand Electric Limited Great King Street North, Birmingham, B19 2LF Tel: 0870 608 9000 Fax: 0870 608 9004 Website: www.legrand.co.uk
This document is printed on sustainably sourced paper. Please recycle.
The Legrand logo is a registered trademark of the Legrand group of companies.
Electrak underfloor to workstation systems guide 01/2013. 5K
Distributor: