ADEMCO N5672V2XX

Page 1

ADDENDUM TO:

INSTALLATION INSTRUCTIONS FOR 4110DL, 4110XM, VIA-16

USE WITH ISSUES:

N5672V2 7/93 (4110DL) N5478V3 12/93 (4110XM) N5478-1V1 7/93 (VIA-16)

RE:

NEW FEATURES

The following features have been added to the above panels: 1. Additional Entry Delay times in program field *38 have been added: 4 = 60 seconds 5 = 90 seconds 2. Additional option for test report timing has been added to program field *48: 2 = Weekly 3. Program field *93 has been added for the purpose of setting the number of Alarm and Alarm Restore communicator reports that can be sent during an armed period. The options are: 0 = 10 Reports 1 = Unlimited Note: Panels that contain these features will report to the downloader as Rev. 05 or higher.

ALARM DEVICE MANUFACTURING CORPORATION A DIVISION OF PITTWAY CORPORATION

165 Eileen Way, Syosset, New York 11791 Copyright Š 1995 PITTWAY CORPORATION

N5672V2XX Rev B 4/99