MANUFACTURING RENOVATION: SOUTHERN TELECOM Site:
Lot in manufacturing disctrict of Brooklyn, NY. Consists of three seperate buildings. An autorepair shop, office both in use, and the warehouse not in use.
Requirements:
Renovate warehouse to be occupiable for two tenants while adding a floor, and utilizing unused space with plumbing from the office building next door as bathrooms.
Design Approach:
Start with facade design based on the NYCECC, and continue based on wall thicknesses to design the interior towards meeting the NYC DOB standards based on zoning laws and building codes.
Responsibilities
This project was handed to me with coments from the client based on an initial design layed out previously. I worked in conjuction with my mentor an RA and Leed AP. We took the project from the design phase to the DOB phase.
Sheena Dee Singh | PG 2/11
7 CLOSED CELL SPRAY FOAM R-38 7”INCH CLOSED CELL SPRAY FOAM INSULATION INSULATION TO ACHIEVE R-38 CASING BEAD CASING BEAD 1/4" SYSTEM WITH STUCCO 1/4” EIFS EIFS WITH STUCCO 1" INSULATION 1” RIGID RIGID INSULATION CONT. EXISTING BLOCK EXISTING 8”8"BLOCK R 10 2BATT 1/2"INSULATON BATT INSULATION 2 1/2” R-10 W/ 2 1/2"GUAGE 20 GAUGE STUD @ 16" O.C. W/ 21/2” METALMETAL @ 16” O.C. ST. LINTEL @ BLOCK ST. LINTEL @ BLCOK OPENING TYP. OPENING, TYP.
EXPOSED INTERIOR ROOF TRUSSES
SEALANT W/ BACKER SEALANT W/BACKER ROD ROD 1" PROJECTING 1” INSULATED INSULATED PROJECTING WINDOW BY WAUSAU WINDOW ALUMINUM WINDOW ALUMINUM WINDOW WALLWALL FRAME SYSTEM FRAME SYSTEM 3/4" FINISH 3/4”FLOOR FLOOR FINISH
3/4”PLYWOOD PLYWOOD SUBFLOOR 3/4" SUBFLOOR 4 1/2” 1/2" CONCRETE CONCRETE SLAB SLAB 2" 20 GAUGE METAL 2” GUAGE METAL DECKDECK SUSPENDED 1/2" GYMPSUM SUSPTENDED 1/2” GYPSUM BOARD CEILING BOARD CEILING 24 GA. ALUM. FLASHING 24 GUAGE ALUMINUM FLASHING
FASTENING CLIPS FASTENING CLIPS
PTD. GYPSUM BOARD PTD. GYPSUM BOARD PTD. EXISTING PTD. EXISTING STL.STL. COL. COL.
LOBBY AND CAFETERIA
1" INSULATION 1” RIGID RIGID INSULATION CONT. 2" RIGID INSULATION 2” RIGID INSULATION TO PREVENT THERMAL BREAK TO PREVENT THERMAL BREAK HORIZONTAL METAL HORIZONTAL METAL PANELPANEL CONCEPT SERIES BY CENTRIA CONCEPT SERIES BY CENTRIA CS-620 GREY CS-620 GREY 15 2BATT 1/2"INSULATON BATT INSULATION 2R1/2” R-10 W/ 2 1/2" 20 GAUGE METAL W/ 21/2” GUAGE METAL @ 16” O.C. STUD @ 16" O.C. 3/4" VINYL TILE FLOOR 3/4” VINYL FLOOR FINISH FINISH
AXO DIAGRAM - PLANS AND SECTION
CS-620 CENTRIA METAL PANEL
PRESSURE TREATED PRESSURE TREATED FIRE RESISTANT WOOD BASE FIRE RESISTANT WOOD BASE SELF LEVELING UNDERLAYMENT SELF LEVELING UNDERLAYMENT
DETAIL WALL SECTION
SETTING BED SETTING BED
ZONING ANDAND LOT INFORMATION ZONING LOT INFORMATION:
138'-412"
MIN. REQUIRED FRONT YARD (FT.): REQUIRED NUMBER OF SIDE YARDS: MIN. REQUIRED TOTAL WIDTH OF SIDE YARDS (FT.) (FOR LOTS WITH FRONTAGE > 40 FT.) REDUCTION OF REQUIRED TOTAL WIDTH OF SIDE YARDS (FT.) FOR LOTS WITH FRONTAGE OF 33 FT. : (40'-33') X 4" = 28" REQUIRED TOTAL WIDTH OF SIDE YARDS FOR LOTS WITH FRONTAGE OF 33 FT.: 13' - 2'-4" MIN. REQUIRED OPEN AREA BETWEEN RESIDENTIAL BUILDINGS MIN. REQUIRED REAR YARD (FT.):
June 10, 2016
DWG. P-001 01 OF 12
79 NARROWS LLC 9614 3RD AVE BROOKLYN, NY 11209
33'-03 4"
32'-113 4"
REAR (SOUTH) LOT LINE
Yards
PLOT PLAN
RESIDENTIAL DEVELOPMENT REGULATIONS:
REQUIRED LOT AREA PLANTING (SQ. FT.): STRIP SIZE: LOT WIDTH (FT.): MINIMUM REQUIRED SIDEWALK WIDTH : WIDTH OF EXISTING PLANTING STRIP Proposed Floor Area WIDTH OF PROPOSED PLANTING STRIP
5'-0"
ZR23-45 ZR23-461(a) ZR23-461(a)
EXISTING
FLOOR FLOOR AREA Front Yard Planting Requirement
2'-4" ZR23-48
FRONT YARD PLANTING: 1220 CELLAR (DEDUCTED) REQUIRED FRONT YARD PLANTING AREA:
10'-8" ZR23-48 8. ZR23-461(c) 30. ZR23-47
9'-0"
9'-0"
ZR23-631(a) 25. 1/1 ZR23-631(a) 30. ZR23-632(b) HEIGHT ABOVE 30 FT /2 30. ZR23-632(b) HEIGHT ABOVE 30 FT /2
9'-0"
9'-0"
9'-2"
1
3/32" = 1'-0"
MINIMUM REQUIRED SIDEWALK WIDTH : WIDTH OF EXISTING PLANTING STRIP WIDTH OF PROPOSED PLANTING STRIP
Front Yard Planting Requirement FRONT YARD PLANTING:
25. ZR23-631(a) 1/1 ZR23-631(a) 30. ZR23-632(b) HEIGHT ABOVE 30 FT /2 30. ZR23-632(b) HEIGHT ABOVE 30 FT /2
ATTIC TOTAL
PROPOSED FA EXCEED
FAR Analysis: ZR23-632(b) ZR23-632(b)
1 ZR25-22 2 1 < 2 EXISTING NON-COMPLIANCE 1 EXISTING NON-COMPLIANCE
1 TREE REQUIRED ZR23-03(b) 0 0 0 0 1 REQUIRED PER ZR23-04 (SPECIAL BAY RIDGE DISTRICT) DEVELOPMENT
WIDTH FEASIBLE GIVEN THE REQUIRED MINIMUM 4582. "THE > GREATEST 3800. OK. PAVED WIDTH OF THE SIDEWALK..." (ZR26-42) 33. < 40. EXISTING NON COMPLIANCE 5'-0" (PER DOT STREET DESIGN) 6'-8" 6'-8" (NO CHANGE) ADDITIONAL FLOOR AREA 553 340 19
ATTIC
0
1120
TOTAL
2412
1479
TOTAL PROPOSED FLOOR AREA
REQUIRED (ZR23-451) 1773 STREET WALL WIDTH= 20'< 33'.16 <34' 25% 1546 AREA REQUIRED (ZR23-451) 15% 1225 (EXISTING NON-COMPLIANCE) SEE DIAGRAM BELOW. 15% (SEE DIAGRAM BELOW) NO CHANGE 1120 YEAR BUILDING BUILT= 1925 ; PRIOR TO APR. 30, 2008 NO INCREASE IN THE DEGREE OF NON-COMPLANCE, OK (ZR23-451) 3891
PROPOSED FA EXCEEDS ALLOWABLE EXISTING FAR PROPOSED FAR
ZR23-632(b)
1 ZR25-22 2 1 < 2 EXISTING NON-COMPLIANCE 1 EXISTING NON-COMPLIANCE
(2412 SF/4582 SF) = (3891 SF/4582 SF) =
Existing Open Space Analysis
ZR23-632(b)
BASE PLANE
BASE PLANE 1 TREE REQUIRED ZR23-03(b) 0 0 0 0 1
REQUIRED PER ZR23-04 (SPECIAL BAY RIDGE DISTRICT) "SHALL BE LOCATED ADJACENT TO, AND EXTEND ALONG, THE ENTIRE LENGTH OF THE CURB OF THE STREET. HOWEVER IN THE EVENT THAT BOTH ADJOINING PROPERTIES HAVE PLANTING STRIPS ADJACENT TO THE FRONT LOT LINE, SUCH PLANTING STRIP MAY BE LOCATED ALONG THE FRONT LOT LINE." (ZR26-42) COMPLIANT/PROVIDED AT STREET LINE
PROPOSED SIDE TO SIDE SECTION
REQUIRED STRIP SIZE: PROPOSED SIDEPLANTING TO SIDE SECTION 3/32" = 1'-0"
SECOND FLOOR
0.53 > 0.5 EXISTING NON-COMPLIANCE 0.85 > 0.50 NON-COMPLIANCE
EXISTING LOT COVERAGE(SQ. FT.): EXISTING OPEN SPACE AREA (SQ. FT.): EXISTING OPEN SPACE RATIO :
1206 4582-1206= 3376 3376/2412 X100 = 140 < 150 EXISTING NON-COMPLIANCE.
PROPOSED LOT COVERAGE(SQ. FT.): PROPOSED OPEN SPACE AREA (SQ. FT.): PROPOSED OPEN SPACE RATIO :
1525 4582-1546= 3036 3036/3891 X100 = 78 < 150 NON-COMPLIANCE.
Proposed Open Space Analysis
Existing Yards
FRONTAGE: 33'/25 TOTAL NUMBER OF TREES REQUIRED BY NYC DOB: EXISTING TREES TO PROTECT : PROPOSED TREES TO REMOVE/RELOCATE PROPOSED TREES TO PLANT: PROPOSED TREES TO PLANT OFF SITE: PROPOSED TREES TO PAY INTO TREE FUND:
P-011
FIRST FLOOR
FAR Analysis:
Street Tree Requirement
22'-2"
1206
FIRST FLOOR
EXISTING PLANTING SECOND FLOOR AREA: 1206 PROPOSED PLANTING AREA:
Off-Street Parking
10'-0" 10'-11"
1'-2" 25'-512" EXISTING TO REMAIN
12'-11"
5'-0"
12'-11"
35'-0" 7'-0" 10'-0"
13'-10" 35'-0"
10'-0"
MAX. HEIGHT OF FRONT WALL ABOVE FRONT YARD LINE (FT): PERMITTED SLOPE OF SKY EXPOSURE PLANE (VERTICAL/HORIZONTAL) MAX. PERMITTED HEIGHT OF WALL BOUNDING SIDE YARD(FT.): REQUIRED SETBACK OF WALL BOUNDING SIDE YARD(FT.): MAX. PERMITTED HEIGHT OF WALL BOUNDING REAR YARD(FT.): REQUIRED SETBACK OF WALL BOUNDING REAR YARD(FT.):
MIN. REQUIRED OFF STREET PARKING SPACE PER DWELLING REQUIRED NUMBER OF OFF STREET PARKING SPACES EXISTING NUMBER OF STREET PARKING SPACE 22'-2" PROPOSED NUMBER OF STREET PARKING SPACE (NO CHANGE)
CELLAR (DEDUCTED)
10'-8" ZR23-48 8. ZR23-461(c) 30. ZR23-47
REQUIRED PLANTING "SHALL EXISTING BE LOCATED ADJACENT TO, AND EXTEND ALONG, EXISTING USE GROUPSTRIP LOCATION: 2A (TWO-FAMILY RESIDENCE) NON-COMPLIANCE THE ENTIRE LENGTH OF THE CURB OF THE STREET. 2B ACCESSORY TO RESIDENCE EXISTING NON-COMPLIANCE HOWEVER IN&THE EVENT THAT BOTH ADJOINING PROPERTIES HAVE (OFF STREET PARKING + BOILER STORAGE) PLANTING STRIPSNON-COMPLIANCE ADJACENT TO THE FRONT LOT LINE, SUCH PLANTING 2A (TWO-FAMILY RESIDENCE) EXISTING PROPOSED USE GROUP STRIP MAY BE LOCATED ALONG THE FRONT LOT LINE." (ZR26-42) 2B ACCESSORY TO RESIDENCE EXISTING NON-COMPLIANCE COMPLIANT/PROVIDED (OFF STREET PARKING + BOILER & STORAGE)AT STREET LINE
Height & Setback
PLANTING STRIP REQUIREMENT: REQUIRED PLANTING STRIP LOCATION:
P-011
15. 2. 13.
(FOR LOTS WITH FRONTAGE > 40 FT.) REDUCTION OF REQUIRED TOTAL WIDTH OF SIDE YARDS (FT.) FOR LOTS WITH FRONTAGE OF 33 FT. : (40'-33') X 4" = 28" REQUIRED TOTAL WIDTH OF SIDE YARDS FOR LOTS WITH FRONTAGE OF 33 FT.: 13' - 2'-4" MIN. REQUIRED OPEN AREA BETWEEN RESIDENTIAL BUILDINGS MIN. REQUIRED REAR YARD (FT.):
Planting Strip Requirement
1
ZR22-11
SIDE 0.5 ZR23-141(a) LINE WEST 150 ZR23-141(a) 22'-3" 6'-11" 2'-9" REQUIRED SIDE YARD 3800. ZR23-32 (10.67'-3.83') (ZR23-48)40. ZR23-32 9'-8" 1900. ZR23-22
Yards 22'-3" 2'-9" MIN. REQUIRED FRONT YARD (FT.):6'-11" (10.67'-3.83') REQUIRED NUMBER OF SIDE YARDS: MIN. REQUIRED TOTAL WIDTH OF SIDE YARDS (FT.) 9'-8"
3'-10"
13'-10"
8'-712"
10'-0"
1A & 1B LOT
MIN. REQUIRED. LOT AREA SQ. FT.) 1 " MIN. REQUIRED.8'-7 LOT WIDTH (FT.): 2 MAX. NO OF DWELLING FACTOR:
EXISTING SIDE YARD NON-COMPLYING
LOT AREA (SQ. FT.): LOT WIDTH (FT.):
Proposed Floor A
"THE GREATEST WIDTH FEASIBLE GIVEN THE REQUIRED MINIMUM PAVED WIDTH OF THE SIDEWALK..." (ZR26-42) 5'-0" (PER DOT STREET DESIGN) 6'-8" 6'-8" (NO CHANGE)
REQUIRED (ZR23-451)
EXISTING FRONT YARD (FT.) EXISTING EAST SIDE YARD EXISTING WEST SIDE YARD EXISTING TOTAL WIDTH OF SIDE YARDS (EAST + WEST) EXISTING DISTANCE BETWEEN ADJACENT BUILDING (EAST) EXISTING DISTANCE BETWEEN ADJACENT BUILDING (WEST) EXISTING REAR YARD
21'-6" > 15' 3'-10" < 5' 8'-11' > 5' 12'-9" > 10'-8" 8'-7 1/2"> 8' 7'-8" > 8' 55'-9" >30'
OK EXISTING NON-COMPLIANCE OK OK OK OK OK
21'-6" > 15' 3'-10" < 5' 6'-11' > 5' 10'-9" > 10'-8" 8'-7 1/2"> 8' 9'-8" > 8' 42'-1" >30'
OK EXISTING NON-COMPLIANCE OK OK OK OK OK
Proposed Yards PROPOSE FRONT YARD (FT.) PROPOSED EAST SIDE YARD PROPOSED WEST SIDE YARD PROPOSED TOTAL WIDTH OF SIDE YARDS (EAST + WEST) PROPOSED DISTANCE BETWEEN ADJACENT BUILDING (EAST) PROPOSED DISTANCE BETWEEN ADJACENT BUILDING (WEST) PROPOSED REAR YARD
Proposed Height & Setback
EXISTING FAR PROPOSED FAR
(2 (3
Existing Open Sp
EXISTING LOT COVERA EXISTING OPEN SPACE EXISTING OPEN SPACE
Proposed Open S
PROPOSED LOT COVER PROPOSED OPEN SPA PROPOSED OPEN SPA
Existing Yards
FRONTAGE: 33'/25 TOTAL NUMBER OF TREES REQUIRED BY NYC DOB: EXISTING TREES TO PROTECT : PROPOSED TREES TO REMOVE/RELOCATE PROPOSED TREES TO PLANT: PROPOSED TREES TO PLANT OFF SITE: PROPOSED TREES TO PAY INTO TREE FUND:
Planting Strip Requirement REQUIRED SIDE YARD PLANTING STRIP REQUIREMENT: ANALYSIS OF PROPOSED (ZR23-48)
9'-2"
SIDE LOT LINE EAST
ZR23-45 ZR23-461(a) ZR23-461(a)
Height & Setback
SIDE LOT LINE WEST
5'-0"
EXISTING SIDE YARD Permitted Use Group NON-COMPLYING MAX. PERMITTED RESIDENTIAL F.A.R.: 5'-0" MIN. REQUIRED OPEN SPACE RATIO: 3'-10"
15. 2. 13.
PROPOSED USE GROUP
Street Tree Requirement
R2 BAY RIDGE 22A 3150716 RES 4 FRAME
LINE EAST
MIN.REQUIRED SIDE YARD (ZR 23-46)
EXISTING USE GROUP
FLOOR
MIN. REQUIRED OFF STREET PARKING SPACE PER DWELLING REQUIRED NUMBER OF OFF STREET PARKING SPACES EXISTING NUMBER OF STREET PARKING SPACE PROPOSED NUMBER OF STREET PARKING SPACE (NO CHANGE)
5976 20
ZONING DISTRICT: SPECIAL DISTRICT: MIN.REQUIRED SIDE ZONING MAP #: YARD (ZR 23-46) BIN: (NO CHANGE) OCCUP. CL.: SIDE LOT CONSTR CL.: Lot Area
ZR23-141(a) ZR23-141(a) ZR23-32 ZR23-32 ZR23-22
Off-Street Parking
ZONING AND LOT INFORMATION: BLOCK LOT
ANALYSIS O
ZR22-11
0.5 150 3800. 40. 1900.
2'-4" ZR23-48
MAX. HEIGHT OF FRONT WALL ABOVE FRONT YARD LINE (FT): PERMITTED SLOPE OF SKY EXPOSURE PLANE (VERTICAL/HORIZONTAL) MAX. PERMITTED HEIGHT OF WALL BOUNDING SIDE YARD(FT.): REQUIRED SETBACK OF WALL BOUNDING SIDE YARD(FT.): MAX. PERMITTED HEIGHT OF WALL BOUNDING REAR YARD(FT.): REQUIRED SETBACK OF WALL BOUNDING REAR YARD(FT.):
PLANTING
1/16" = 1'-0"
7'-0"
P-001
PROPOSED PLOT PLAN.
1A & 1B
MAX. PERMITTED RESIDENTIAL F.A.R.: MIN. REQUIRED OPEN SPACE RATIO: MIN. REQUIRED. LOT AREA SQ. FT.) MIN. REQUIRED. LOT WIDTH (FT.): MAX. NO OF DWELLING FACTOR:
66 79TH ST. 66 79TH STREET BROOKLYN, NY 11209
3'-10" 22'-13 4" 6'-11"
REAR YARD
42'-2" REAR YARD
TRANSVERSE SECTION Sheena Dee Singh | PG 4/11
43'-612" EAST LOT LINE
2'-9"
EXISTING 2 STORY BRICK
Permitted Use Group
PROPOSED ADDITION 1
10'-11"
The initial site visit along with existing and demolition drawings were completed before the project was handed to me. Due to building envelope and special district restrictions, according to the DOB this project was to be sent over the Board of Standards and Appeals (BSA). All construction documents were reformated to meet BSA requirements.
73'-8" WEST LOT LINE
11'-8" 6'-8"
FRONT YARD 21'-51 " 2
Design Approach:
Responsibilities
PROPOSED EXTENSION
PROPOSED 2 STORY STUCCO FRAME AND ATTIC
140'-012"
Demolish the whole building except for two foundation walls and the first floor structure to create a new 2-family building under an Alt-1 type DOB job application.
Consult the clients opinion on the entrance and begin by determining elevations of all levels (except existing first floor) including necessary sturcture while working closely with the structural engineer. Move into circulation and egress according to clientâ&#x20AC;&#x2122;s needs and building code to then begin designing the rest of the space accordingly.
3'-10" EASEMENT DRIVEWAY
R2 BAY RIDGE 22A 3150716 RES 4 FRAME
RESIDENTIAL DEVELOPMENT REGULATIONS:
MASONRY GARAGE
57'-03 4"
13'-612"
8'-812"
SIDEWALK
(60' WIDE)
Requirements:
9'-5"+/-
4'-912"
60'-112"
13'-5"
33'-2"
EXISTING 2 STORY BRICK
21'-21 4"
79TH STREET
Sloped site with a driveway leading to the garage in the back.
21'-7"
STREET FURNITURE
5976 20
ZONING DISTRICT: SPECIAL DISTRICT: ZONING MAP #: BIN: (NO CHANGE) OCCUP. CL.: CONSTR Lot AreaCL.:
Project owner:
STREET (NORTH) LINE
Scale: AS NOTED
HOUSE NO. : 66 BLOCK : 5976 LOT : 20
CURB
Site:
PROPOSED PLOT PLAN
BLOCK LOT
1'-2" 25'-512" EXISTING TO REMAIN
RES 2-FAMILY NEW BUILDING: BSA ELITE DEN
FRONT WALL HEIGHT ABOVE FRONT YARD LINE (FT): N/A FRONT WALL SETBACK 10'-3" FROM FRONT YARD LINE 1/1 OK PROPOSED SLOPE OF SKY EXPOSURE PLANE (VERTICAL/HORIZONTAL): PROPOSED HEIGHT OF WALL BOUNDING SIDE YARD(FT.): 30. OK PROPOSED SETBACK OF WALL BOUNDING SIDE YARD(FT.): 2'-6" OK PROPOSED HEIGHT OF WALL BOUNDING REAR YARD(FT.): 30. OK PROPOSED SETBACK OF WALL BOUNDING REAR YARD(FT.): N/A REAR WALL SETBACK 12'-1" FROM REAR YARD LINE
EXISTING FRONT YARD EXISTING EAST SIDE YA EXISTING WEST SIDE Y EXISTING TOTAL WIDT EXISTING DISTANCE BE EXISTING DISTANCE BE EXISTING REAR YARD
Proposed Yards
PROPOSE FRONT YARD PROPOSED EAST SIDE PROPOSED WEST SIDE PROPOSED TOTAL WID PROPOSED DISTANCE PROPOSED DISTANCE PROPOSED REAR YARD
Proposed Height &
FRONT WALL HEIGHT A PROPOSED SLOPE OF S PROPOSED HEIGHT OF PROPOSED SETBACK O PROPOSED HEIGHT OF PROPOSED SETBACK O
EAST LOT LINE 138'-412"
42'-012"
6'-6"
3'-0"
3'-10"
68'-8" 60'-112" EXISTING TO REMAIN
REF. 15'-0"
21'-712"
19'-912"
16'-9"
FAMILY ROOM 302 SQ FEET
6'-2"
2'-8"
SECOND FLOOR TERRACE ABOVE FIRST FLOOR AND REAR YARD
33'-03 8"
8'-2"
14'-2"
DINING ROOM 258 SQ FEET
6'-11"
2'-8"
22'-112"
15'-0"
LIVING ROOM 317 SQ FEET
20'-112"
20'-2" EXISTING TO REMAIN
TERRACE BELOW 33'-115 " 16
KITCHEN 162 SQ FEET
32'-1113 16"
21'-25 16"
42'-17 8" 21'-51 " 2 FRONT YARD
PROPOSED SECOND FLOOR PLAN
1 P-004
3/32" = 1'-0"
NOTE: PROPOSED ELEVATION OF SECOND FLOOR IS HIGHER THAN EXISTING SECOND FLOOR. NO FLOOR TO REMAIN. EXISTING LINEAR WALL= (60'-1 21" X (2)) + 20'-2"X (2)=160'-7" EXISTING WALL TO REMAIN= 60'-1 21" + 20'-2"= 80'-3 21" PERCENTAGE OF WALL TO REMAIN= 50%
140'-1"
EAST LOT LINE 138'-412"
66'-4"
13'-2"
TERRACE BELOW
5'-6"
13'-2"
6'-11
2'-8"
LAUNDRY 85 SQ FEET
6'-5"
6'-412"
16'-1112"
33'-03 8"
BEDROOM 175 SQ FEET
32'-1113 16"
5'-10"
22'-112"
BEDROOM 185 SQ FEET
13'-412"
5'-8" BATHROOM 75 SQ FEET
BEDROOM 433 SQ FEET
13'-4"
13'-712"
9'-10"
33'-115 " 16
20'-112"
18'-4"
48'-69 16"
3'-10116"
2'-313 16"
21'-25 16"
42'-17 8" 21'-51 " 2
FRONT YARD
PROPOSED ATTIC FLOOR PLAN
1 P-005
3/32" = 1'-0"
NOTE: FLOOR LAYOUT AND MAXIMUM ATTIC FLOOR AREA OF 1120 SQ. FEET. SHALL BE AS APPROVED BY DOB PROPOSED ELEVATION OF ATTIC IS HIGHER THAN EXISTING ATTIC. NO WALLS OR FLOOR TO REMAIN.
PRELIMINARY SKETCH MIN.REQUIRED SIDE YARD (ZR 23-46)
138'-412" EAST LOT LINE
21'-25 16"
3'-10"
24'-412"
19'-2"
5'-7"
32'-1113 16"
6'-0"
33'-03 8"
20'-2" BEDROOM 214 SQ FEET
22'-112"
5'-0"
6'-4"
4'-612"
5'-112"
15'-0"
6'-11"
6'-8"
42'-512"
31'-012"
5'-0"
8'-3"
WD
3'-9"
30'-5" to entrance
43'-3" 42'-17 8"
6'-8"
21'-51 " 2
FRONT YARD
1
PROPOSED FIRST FLOOR PLAN 3/32" = 1'-0"
7'-0"
P-003
10'-0"
13'-10"
21'-0"
DINING ROOM 193 SQ FEET
17'-8"
NOTE: EXISTING 1ST FL. FLOOR AREA= 60'-1 21" X 20'-2"= 1212.5 SQ FT PROPOSED FLOOR AREA= (18'-2"X17'-8")+(20'-2"X42'-5 21")=1177.4 PERCENTAGE OF FLOOR TO REMAIN=97.1% 1 STREET TREE REQUIRED PER ZR 23-03 TO BE PAID IN TO TREE FUND
140'-1"
EAST LOT LINE 138'-412"
78'-518"
20'-112"
33'-115 " 16
1'-2"
6'-27 16"
80'-103 4"
4'-2"
83'-17 8"
42'-17 8" 6'-8"
21'-51 " 2 FRONT YARD
1 P-002
1 P-007
3/32" = 1'-0"
3/32" = 1'-0"
NOTE: EXISTING LINEAR FOUNDATION WALL= (60'-3 21" X (2)) + 20'-2"X (2)= 160.9' EXISTING LINEAR FOUNDATION WALL TO REMAIN= 60'-3 21" PERCENTAGE OF LINEAR FOUNDATION WALL TO REMAIN= 37.5% ALL INTERIOR PARTITIONS SHALL BE AS APPROVED BY DOB
PROPOSED NORTH ELEVATION
PROPOSED NORTH FACADE ELEVATION
PROPOSED CELLAR FLOOR PLAN
PROPOSED PLANS
140'-1"
33'-03 8"
55'-115 8"
6'-3"
32'-1113 16"
20'-99 16" 13'-3"
18'-0"
13'-43 4"
60'-312" EXISTING CELLAR WALL
3'-10116"
21'-67 8"
22'-112"
10'-0"
6'-47 8"
PARALLEL TO STREET LINE AT GARAGE DOOR
20'-113 16" EXISTING TO REMAIN
18'-0"
10'-11"
35'-0"
KITCHEN 146 SQ FEET
14'-112"
14'-2"
LIVING ROOM 258 SQ FEET
8'-0"
8'-8"
15'-11"
3'-2"
8'-712"
6'-11" 2'-9" (10.67'-3.83') 9'-8"
13'-612"
REF.
18'-2" EXISTING WALL TO REMAIN
22'-3"
43'-612"
60'-112" EXISTING WALL TO REMAIN
9'-6"
3'-1112"
4'-912" 3'-10"
33'-115 " 16
EXISTING SIDE YARD NON-COMPLYING
12'-1"
15'-312"
REQUIRED SIDE YARD (ZR23-48)
73'-8" PROPOSED BUILDING LENGTH
1'-1112"
5'-0"
EXISTING WALLS TO REMAIN
57'-07 8"
SIDE LOT LINE WEST
16'-2"
SIDE LOT LINE EAST
140'-1"
RES 2-FAMILY EXPANSION: THE PENT-HOUSE Site:
Small lot right off the R - Train in the center of Bay Ridge, Brooklyn.
Requirements:
Transform one-family house to two-family with addition of third floor (pent house) and extension into the back yard of the existing floors.
Design Approach:
Each unit shall have as much privacy as possible while creating circulation based on existing location of stairs.
Responsibilities
This project was my â&#x20AC;&#x153;babyâ&#x20AC;?, with basic supervision, I had the opportunity to take this project from the initial site visit all the way to the beginning of the construction phase. This included all DOB work.
Sheena Dee Singh | PG 6/11
FIRST FLOOR PLAN
SECOND FLOOR PLAN
PENTHOUSE FLOOR PLAN
MIXED USE REMODELING: GOURMET FRESH
1 A-303
80'-0"
3'-9"
50'-212"
UP
28'-312"
1'-6"
1
DN
A-301
D/W
TANNING ROOM
STORAGE VEST. BATHROOM
STORAGE
16'-91 4"
20'-0"
EXISTING 2 HOUR FIRE RATED WALL
Site:
18'-6" KITCHEN
Two adjacent lots owned by the same corporation with commericial use on the first floor and residential apartments above.
WAXING ROOM
1
WAXING ROOM
12'-6"
S.
3'-4"
2'-0"
DELI BE RELOCATED WITHIN 437-439 COURT STREET
30'-7"
EXISTING DISPLAY SHELVES
6'-61 4"
Redesign the existing beauty salon to an extension of the adjacent supermarket. Create openings between the foundation wall for circulation throughout the two lots.
DELI 1'-412"
23'-312" 1
F.
3'-4"
A-302
CH.
4'-4"
S.
HOT
Requirements:
COUNTER
2'-101 4"
S. DAIRY REF. TO BE RELOCATED INTO 435 COURT STREET
DAIRY REF. TO BE RELOCATED INTO 435 COURT STREET
8'-8"
DISPLAY SHELVES TO BE RELOCATED INTO 435 COURT STREET
1'-6"
A-301
W 8 X 21
3'-4"
A-302
DN
UP
1
8'-4"
DISPLAY SHELVES TO BE RELOCATED WITHIN 437-439 COURT ST.
DISPLAY SHELVES TO BE RELOCATED WITHIN 437-439 COURT ST.
DISPLAY SHELVES TO BE RELOCATED WITHIN 437-439 COURT ST.
CHECKOUT
BATHROOM
DISPLAY SHELVES BEVERAGES REFRIGERATION
Design Approach:
FROZEN FOODS
53'-0"
38'-0" 91'-0"
1
Treat both lots as one large lot, and design accordingly.
A-303
# 1
EXISTING DEMOLITION FIRST FLOOR PLAN A-102
DESIGNATES DEMOLITION WORK AS FOLLOWS:
1. 2. 3. 4. 5. 6.
EXISTING FIRST FLOOR 1/4" = 1'-0"
7. 8. 9. 10. 11. 12.
Responsibilities
13. 14.
This project was my “baby”, with basic supervision, I had the opportunity to take this project from the initial site visit all the way to the beginning of the construction phase. This included all DOB work.
15. 16. 17. 18.
LIGHTING WORK AREA
REMOVE BOARD PARTITION REMOVE MASONRY WALL REMOVE FLOOR COVERINGS REMOVE DOOR AND FRAME IN THEIR ENTIRETY REMOVE WINDOW AND FRAME IN THEIR ENTIRETY REMOVE CEILING, INCLUDING SHEATHING, PLASTER AND FURRING WHERE APPLICABLE REMOVE STAIRS OR STEPS REMOVE BUILT-IN FURNITURE, CABINETRY, ETC. REMOVE APPLIANCES REMOVE SUB-FLOORING REMOVE MECHANICAL EQUIPMENT CUT FLOOR STRUCTURE IN ITS ENTIRETY. SEE STRUCTURAL DRAWINGS FOR OPENING FRAMING PLAN AND DETAILS. REMOVE PLUMBING FIXTURES. REMOVE ROOF STRUCTURE IN ITS ENTIRETY. SEE STRUCTURAL DRAWINGS FOR OPENING FRAMING PLAN AND DETAILS. REMOVE COLUMNS AND POSTS. REMOVE AND RELOCATE BUILT IN FURNITURE, CABINETRY, ETC. REMOVE AND RELOCATE APPLIANCES REMOVE AND RELOCATE PLUMBING FIXTURES
EXISTING EXHAUST FAN TO OUTDOOR WITH 50 CFM CAPACITY
1 A-303
80'-0" 50'-212"
28'-312"
1'-6"
SYMBOL
SM WM 1
SML
A-301
ML22/R (BB)
38' TRACK
20'-0" 72' TRACK
12' TRACK
GOURMET FRESH EXTENDED
VOLTS
NO.
REMARK
TYPE
BB CCU
CEILING CASSETTE UNIT
EXIT SIGN MODULAR FLOURESCENT
EF
2'X2' RATED WATTAGE = 50W / 60W
ML RDG RL
D-5" RATED WATTAGE = 10W
RLS
D - 2 5/8", RATED WATTAGE = 60W
SDD
EXHAUST FAN ELECTRIC SPLICE BOX
MODULAR LED RETURN DUCT GRILL PROPOSED LIGHTING
RECESSED LED SPOTLIGHT SUPPLY DUCT DIFFUSER
SM
SURFACE MOUNTS
RDG
RECTANGLE
SML
SURFACE MOUNTED ROUND LED
SDD
RECTANGLE
TL
ROUND (D=12")
MLX
ROUND (D=12") LED WALL MOUNTED
SDD
LINE DIFFUSER
HZ-K2653L-WH E26 1 CIRCUIT 3 WIRES 1 CIRCUIT 3 WIRES BLACK ALUMINUM
RECESSED LED
HANGING FROM CEILING
RDG
TUBE/STRIP LED
WM
WALL MOUNTS
UL
UTILITY LIGHT
LIGHTING POWER LEGEND: - SWITCHES FOR LIGHTING & DIFFUSER
WITH COVER IN CEILING 2'X4' NOTE:
12'-6"
INTERIOR LIGHTING POWER DENSITY
1. LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS REQUIRED IN SECTIONS 505.2.1, 505.2.2, 505.2.3 AND 505.2 OF THE NYECCC 2. EACH ZONE SHALL BE CONTROLLED BY A SINGLE THERMOSTAT ( ) AS PER SECTION 503.3 OF THE NYCECCC
SYMBOL
LIGHTING FIXTURE LEGEND
WM
1
EF ESB ES ML RL
LIGHTING FIXTURE LEGEND
D-5" RATED WATTAGE = 10W
SM WM SML ML22/R (BB)
RATED WATTAGE = OVER 4W /ft
ESPC
RATED WATTAGE = OVER 4W /ft
ML
WITH COVER IN CEILING 2'X4'
3/16" = 1'-0"
EF ESB ES MF ML RDG RL
EXHAUST FAN ELECTRIC SPLICE BOX EXIT SIGN MODULAR FLOURESCENT
LIGHTING POWER LEGEND: - SWITCHES FOR LIGHTING & DIFFUSER PROPOSED LIGHTING
RECESSED LED RECESSED LED SPOTLIGHT SUPPLY DUCT DIFFUSER
RECTANGLE
SDD
RECTANGLE ROUND (D=12")
SML SURFACE MOUNTED ROUND LED 2. EACH ZONE SHALL BE CONTROLLED BY A SINGLE THERMOSTAT ( ) AS PER SECTION 503.3 OF THE NYCECCC TL TUBE/STRIP LED 3. NO CHANGE IN LIGHTING, POWER, OR ENERGY OTHER THAN AREA MARKED AS " LIGHTING WORK AREA" WM WALL MOUNTS
MLX
ROUND (D=12") LED WALL MOUNTED
4. NO CHANGE IN LIGHTING, POWER, OR ENERGY IN EXISTING VESTIBULES, OR EXISTING STAIRS. UL
WITH COVER IN CEILING
SALES AREA SUSPEND 9'-0" AFF 122' TRACKS PROPOSED
MODULAR LED RETURN DUCT GRILL
RLS SDD
RDG
LINE DIFFUSER
PROPOSED LIGHTING
RECESSED LED SPOTLIGHT
SUPPLY DUCT DIFFUSER LED PAR 38 SPOT LAMP ---- UL HZ-PAR 38 - 19W SM SURFACE MOUNTS 122*H128MM HZ-K2653L-WH 19W E26 SML SURFACE MOUNTED ROUND LED AC120V 50-60HZ 1 CIRCUIT 3 WIRES TL 3 TUBE/STRIP LED 1PC OOB LED 1 CIRCUIT WIRES 170AM @ 300K BLACK WM WALL MOUNTS ALUMINUM >82 UL UTILITY LIGHT
CEILING CASSETTE UNIT
RDG
INTERIOR LIGHTING POWER DENSITY
LIGHTING POWER LEGEND: - SWITCHES FOR LIGHTING & DIFFUSER
DAYLIGHT ZONE
197
GOURMET FRESH EXTENSION
985
38'-0"
INTERIOR LIGHTING POWER DENSITY
1. LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS REQUIRED IN SECTIONS 505.2.1, 505.2.2, 505.2.3 AND 505.2 OF THE NYECCC
AREA (SF)
ROOM
UTILITY LIGHT
2'X4' NOTE:
PROPOSED REFLECTED CEILING PLAN
CCU
SM SURFACE MOUNTS 505.2.3 AND 505.2 OF THE NYECCC 1. LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS REQUIRED IN SECTIONS 505.2.1, 505.2.2,
2. EACH ZONE SHALL BE CONTROLLED BY A SINGLE THERMOSTAT ( ) AS PER SECTION 503.3 OF THE NYCECCC
4. NO CHANGE IN LIGHTING, POWER, OR ENERGY IN EXISTING VESTIBULES, OR EXISTING STAIRS.
REFLECTED CEILING PLAN
REMARK
RETURN DUCT GRILL
SDD
HANGING FROM CEILING
3. NO CHANGE IN LIGHTING, POWER, OR ENERGY OTHER THAN AREA MARKED AS " LIGHTING WORK AREA"
1
TYPE
MODULAR FLOURESCENT
HZ-K2653L-WH E26 1 CIRCUIT 3 WIRES 1 CIRCUIT 3 WIRES BLACK ALUMINUM
RECESSED LED
RLS
BATTERY BACKUP
NOTE:
ML
A-105
NO.
D-5" RATED WATTAGE = 10W
SDD
91'-0"
VOLTS
BB
D - 2 5/8", RATED WATTAGE = 60W
ESPC
53'-0"
ES CF18/3-L - COMPACT FLUORESCENT, (3) 13W LAMP, RATED RDG RECTANGLE WATTAGE = 48W SDD CF18/3-L - COMPACT FLUORESCENT, (3) 13W LAMP, RATED RECTANGLE WATTAGE = 48W ROUND (D=12") RDG ROUND LED SPOT ON TRACK D - 5" RATED WATTAGE = 30 W A-302 ROUND (D=12") LED WALL MOUNTED MLX 1 2'X2' RATED WATTAGE = 50W / 60W SDD LINE DIFFUSER
TL
ES
1
RLS
TL RL RLS
A-303
DESCRIPTION
30'-7"
GOURMET FRESH
SYMBOL
LAMPS
AREA (SF)
ROOM DAYLIGHT ZONE
197
GOURMET FRESH EXTENSION
985
ALLOWABLE DENSITY (W)
PROPOSED DENSITY (W)
ALLOWABLE DENSITY (W)
AREA (SF)
197 DAYLIGHT ZONE LED PAR 38 SPOT LAMP ---- UL SALES AREA SUSPEND 9'-0" AFF 985 FRESH EXTENSION HZ-PAR 38 GOURMET - 19W 122' TRACKS PROPOSED 122*H128MM 19W AC120V 50-60HZ 1PC OOB LED 170AM @ 300K >82
MODULAR LED
RDG
RATED WATTAGE = OVER 4W /ft D - 2 5/8", RATED WATTAGE = MODEL 60W MANUFACTURER NO. HANGING FROM CEILING
ELECTRIC SPLICE BOX EXIT SIGN
MF
2'X2' RATED WATTAGE = 50W / 60W RATED WATTAGE = OVER 4W /ft
TL
EXISTING LIGHTING FIXTURES SCHEDULE TYPE
EXHAUST FAN
TL RL
Sheena Dee Singh | PG 8/11
MANUFACTURER
ROUND LED SPOT ON TRACK D - 5" RATED WATTAGE = 30 W
SML ML22/R (BB) A-302
DESCRIPTION
4. NO CHANGE IN LIGHTING, POWER, OR ENERGY IN EXISTING VESTIBULES, OR EXISTING STAIRS. BATTERY BACKUP BB LAMPS MODEL REMARK NO. CCU CEILING CASSETTE UNIT VOLTS NO. TYPE
CF18/3-L - COMPACT FLUORESCENT, (3) 13W LAMP, RATED WATTAGE = 48W CF18/3-L - COMPACT FLUORESCENT, (3) 13W LAMP, RATED WATTAGE = 48W
SM
ROOM
3. NO CHANGE IN LIGHTING, POWER, OR ENERGY OTHER THAN AREA MARKED AS " LIGHTING WORK AREA"
EXISTING LIGHTING FIXTURES SCHEDULE TYPE
LED PAR 38 SPOT LAMP ---- UL HZ-PAR 38 - 19W 122*H128MM 19W AC120V 50-60HZ 1PC OOB LED 170AM @ 300K >82
BATTERY BACKUP
ES MF
RATED WATTAGE = OVER 4W /ft
ML
1
LAMPS
MODEL NO.
ROUND LED SPOT ON TRACK D - 5" RATED WATTAGE = 30 W
RATED WATTAGE = OVER 4W /ft
ESPC
A-301
MANUFACTURER
ESB
TL
ES
DAYLIGHT ZONE AND ENTRANCE
DESCRIPTION CF18/3-L - COMPACT FLUORESCENT, (3) 13W LAMP, RATED WATTAGE = 48W CF18/3-L - COMPACT FLUORESCENT, (3) 13W LAMP, RATED WATTAGE = 48W
TL RL RLS
18'-6"
LIGHTING FIXTURE LEGEND
EXISTING LIGHTING FIXTURES SCHEDULE TYPE
PROPOSED DENSITY (W)
ALLOWABLE DENSITY (W)
PROPOSED DENSITY (W)
1 A-303
80'-0" 28'-312"
1 A-301
DAIRY REF. RELOCATED
DAIRY REF. RELOCATED
3'-1012"
3'-0"
9'-6"
12'-8"
3'-9"
RELOCATED
A'
PREPARED FOOD RELOCATED
MEATS RELOCATED
12'-6"
A
2'-11" OPENING TO LOT LINE
4'-33 4"
14'-0"
10'-0"
3'-3"
3'-6"
PROPOSED GAS RISER DIAGRAM 3/16" = 1'-0"
GAS RISER DIAGRAM
DELI AREA RELOCATED
7'-5"
4'-0" DISPLAY SHELVES RELOCATED
HOOD
2 A-602
FR
B
34'-0"
5'-4"
BELT
CH
STOVE
4'-13 4"
2'-0"
HOT
2'-4"
1'-7"
DISPLAY SHELVES
DELI
3'-6"
W 8 X 21
30'-7"
6'-61 4"
EXISTING DISPLAY SHELVES
2'-4"
28'-0"
"
DISPLAY SHELVES RELOCATED
2'-10"
4'-4
1
1'-0"
4'-0"
43'-0" 4'-8"
6'-0"
1'-7"
23'-312"
7'-0"
8'-8" 3'-4"
2'-10" OPENING TO LOT LINE 13'-10" OPENING TO LOT LINE
DISPLAY SHELVES
CHEESE 1
6'-0"
20'-0"
31'-5"
CHECKOUT EXISTING BEVERAGES REFRIGERATION
EXISTING DISPLAY SHELVES
3'-0"
4'-0"
CHECKOUT
2'-4"
1'-0"
4'-212"
5'-1" 8'-0"
16'-4"
DRY PRODUCE CHECKOUT
A-302
4'-0"
3'-4"
16'-11"
8'-4"
DISPLAY SHELVES RELOCATED
LOW BOY
8"
EXISTING DISPLAY SHELVES
BREAD WORK TABLE 2'-
B'
4'-0"
DN
UP TO APARTMENTS
3'-7"
A-302
20'-0"
6'-7" 16'-4"
3'-9"
REF.PRODUCE RELOCATED
REF.PRODUCE 1
12'-0"
32'-0"
1'-0"
24'-4"
3'-1012"
9'-012"
6'-9"
24'-4"
2'-0"
DISPLAY SHELVES RELOCATED
5'-8"
16'-91 4"
4'-4"
3'-0"
3'-11"
14'-8" DRY PRODUCE RELOCATED
28'-912"
A-301
DAIRY REF. RELOCATED
3'-9"
CHEESE PREP
EXISTING 2 HOUR FIRE RATED WALL
DRY PRODUCE RELOCATED
18'-6"
1'-6"
DN
UP TO APARTMENTS VEST.
3'-8"
3'-9"
50'-212"
EXISTING FROZEN FOODS
53'-0"
38'-0" 91'-0" EXISTING EXHAUST FAN TO OUTDOOR WITH 50 CFM CAPACITY
1 A-303
1
PROPOSED FIRST FLOOR PLAN
PROPOSED FIRST FLOOR PLAN A-104
1/4" = 1'-0"
SANITARY RISER DIAGRAM 2
A-601
LOT LINE
PROPOSED SANITARY DIAGRAM 3/16" = 1'-0"
LOT LINE
NOTE: FOOTRESTS MAY EXTEND FURTHER FOR VERY LAGE PE0PLE KITCHEN
LIVING ROOM
BEDROOM
CORRIDOR
KITCHEN
LIVING ROOM
BEDROOM
10'-0"
10'-0"
11'-6"
11'-13 4"
CORRIDOR
60" DIAMETER SPACE
PARALLEL APPROACH
42'-9"
42'-53 4"
42'-0"
FORWARD APPROACH
CORRIDOR
LIVING ROOM
BEDROOM
10'-0"
10'-0"
KITCHEN
435 435
437
439 FRESH PRODUCE
GROCERY
DAIRY
SALON
FROZEN
SUPERMARKET DELI
SUPERMARKET CASH REGISTERS
PARALLEL APPROACH
T-SHAPED SPACE FOR 180° TURNS
PASSAGE POINT
FORWARD APPROACH
ORDINARY CELLAR
STORAGE
WORK AREA
8'-51 4"
30'-212" 8'-9"
20'-0"
11'-3"
11'-4"
DELI
CLEAR FLOOR SPACE
PROPOSED FACADE & TRANSVERSE SECTION
1 A-301
EXISTING TRANSVERSE SECTION
WALLS TO BE DEMOLISHED TO ACCOMMODATE OPENINGS BETWEEN ADJACENT LOTS
1/4" = 1'-0"
LOT # 6
LOT # 5
FORWARD APPROACHPARALLEL APPROACH
HANDICAP NOTES
BAZAAR IN MOTION UNDERGRAD DESIGN: SHAKEN & STIRRED Site:
In Downtown Core of Singapore, this is situated in one of the most dense areas of this island nation. Esplanade Park is the intersection point of the business district on one side, and the tourist district on the other. Where work meets play.
SUPERSTRUCTURE ENCLOSED TREE COLUMN
MESH MODEL STUDIES FOR SPATIAL STRUCTURES
Requirements:
Give the residents who mostly stay in the areas of work and sleep, a reason to step into the areas of play on a more regular basis.
PLANAR STALL PLACEMENT STUDIES
Design Approach:
The vazaar is always bustling with contained excitement. Products and currencies are alwayys circulating at high speeds. The locals will shop in hopes of a good bargain while the tourists come for an authentic experience.
3D PRINT STUDIES FOR ROOF
We divided the project into 3 aspects: -The Occupiable Roof -The Stalls & Circulation -Superstructure Columns
Responsibilities
This 4 month project was completed with a partner. We shared and did all our work together, however, I focused more on the graphic presentation, while my partner worked more on the plans and sections. Sheena Dee Singh | PG 10/11
3D AXONOMETRIC DIAGRAM
SITE PLAN
SECTION
STALL TYPES