1 minute read

STAY IN PLACE FORMWORK

ARN - 303- Building Construction - IV

Date: 24-09-2021

Advertisement

Images From BTMPC manuals and videos

STAY IN PLACE : PVC WALL FORM

Some Imp Codes And Standards Used In Assessment

TESTING/ VERIFICATION PROCESS

NAME: Muskan Aanand (19110016)

Katta Sheetal (19110011)

Amasa Pranay (19110002)

Shreyes Gupta (19110025)

Test Performed And Test Results

Testing of samples by RDH Building Engineering Ltd, USA

Air Leakage Rate and Water Ingress Resistance Tests

These tests were performed by constructing a wall of 1994 mm x 2032 mm using light weight EPS by Plasti-Fab Advantage ICF as formwork for the steel reinforced 150 mm thick concrete A 584 mm x 584 mm fixed window was installed within the wall assembly.

Air Tightness Test in accordance with ASTM E283

When tested to the standard of ASTM E283 at a pressure differential of 75 Pa, the specimen, as prepared, achieved an Air Leakage Rate per fixed area (qA) of less than 0.0039 L/s.m2.

Water Ingress Resistance Test in accordance with ASTM E331

When tested to the standard of ASTM E331, no water ingress resistance was observed through the specimen at differential pressures of 150, 300, 700, 1400 & 5000Pa

Engineering Evaluation of Logix ICF Water Vapour Transmission

Test by Intertek Testing Services NA Ltd., USA

Intertek has conducted an engineering evaluation of Logix Insulated Concrete Forms Ltd, on Logix ICF to determine if the Logix ICF meets the 2005 National Building Code as a vapour barrier The analysis showed that Logix ICF meete the water permeance requirements and can be installed without a vapour barrier

Page No: 4

ARN - 303- Building Construction - IV

Date: 24-09-2021

STAY