6 minute read

Non woven fabric polyester 100 µm

Next Article
July 2021 3/23

July 2021 3/23

Code: 090001

Filmtec RO membranes TFC TW30 1812 - 50, 75, 100 GPD (25)

Advertisement

Variants

Code Description

090001-01 Filmtec RO membrane TFC TW30 1812 - 50 GPD (25) 090001-02 Filmtec RO membrane TFC TW30 1812 - 75 GPD (25) 090001-03 Filmtec RO membrane TFC TW30 1812 - 100 GPD (25)

Code: 090005

Greenfilter RO membranes TFC 1812/2012/3012/3013 - 50, 75, 100, 150, 180, 300, 400 GPD

Variants

Code Description

090005-50 Greenfilter RO membrane TFC 1812 - 50 GPD (25) 090005-75 Greenfilter RO membrane TFC 1812 - 75 GPD (25) 090005-100 Greenfilter RO membrane TFC 1812 - 100 GPD (25) 090005-180 Greenfilter RO membrane TFC 2012 - 180 GPD (25) 090005-300 Greenfilter RO membrane TFC 3012 - 300 GPD (1) 090005-400 Greenfilter RO membrane TFC 3013 - 400 GPD (1)

Definition Reverse osmosis process is based on nature and has been used for more than 30 years. These semipermeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.

Type of membrane: Spiral wound

Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm.

Spacer: EPDM

SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090005-50 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15%

Membrane 75 GPD Cod. 090005-75 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15%

Membrane 100 GPD Cod. 090005-100 Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15%

Membrane 150 GPD Cod. 090005-150 Active surface: x,xxm²(xft²) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts rejection(N2) 97,5% * Recovery del 15%

Membrane 180 GPD Cod. 090005-180 Active surface: x,xxm²(xft²) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts rejection(N2) 93% * Recovery del 15%

Membrane 300 GPD Cod. 090005-300 Active surface: x,xxm²(xft²) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts rejection(N2) 95% * Recovery del 15%

Membrane 400 GPD Cod. 090005-400 Active surface: x,xxm²(xft²) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts rejection(N2) 95% * Recovery del 15%

(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95%

OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm

OPERATING LIMITS OF 150, 180, 300,400 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 8,6 bar (125 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * Free Chlorine tolerance¹ <0,1 ppm

¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max.

GENERAL INFORMATION • All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite and propylene glycol to prevent biological growth in short-term storage and transport.

• It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • To prevent biological growth during prolonged system shutdown, it is recommended that membrane elements be immersed in a preservative solution. • The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Code: 090018

Greenfilter RO encapsulated membranes TFC 50, 75, 100 GPD

Variants

Code Description

090018-01 Greenfilter RO encapsulated membrane TFC 50 GPD 090018-02 Greenfilter RO encapsulated membrane TFC 75 GPD 090018-03 Greenfilter RO encapsulated membrane TFC 75 GPD Filmtec 090018-04 Greenfilter RO encapsulated membrane TFC 100 GPD

High efficiency, disposable encapsulate membranes. Change complete of vessel + membrane for maximum hygiene! These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.

Type of membrane: Spiral wound

Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm.

Spacer: EPDM

SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090018-01 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15%

Membrane 75 GPD Cod. 090018-02 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15%

Membrane 75 GPD Cod. 090018-03 Filmtec® Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15%

(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95%

Connections: * Inlet water: O.D. stem Ø 3/8" * Outlet permeate: O.D. stem Ø 1/4" * Drain: O.D. stem Ø 1/4"

OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm

¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max.

GENERAL INFORMATION • It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • The membrane has a certain short-term resistance against chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Note: The polluting agents removed or reduced by this system are not necessarily in your water. Code: 090017

Ionicore USmotic RO membranes TFC 2012 - 50, 75, 100, 150, 180 GPD (25)

Features

Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day) Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day) Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day)

This article is from: