July 2021 3/23

Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day) Permeate flow rate (+/-20%) 180: 180 Gpd (681 lt./day) Minimum salt rejection: 96% Stabilized salt rejection: 98% Operating pressure test: 65 PSI TDS feed test: Tap Water (from 450 to 700 ppm) Water temperature test: 77°F. (25°C.)

Recovery test: 15%

Advertisement

Max. operating pressure: Max. feed SDI: Max. feed flow rate: 125 - 300 PSIG 5 (15 min) 2 gal./min. (7,57 lt./min.)

Chlorine tolerance: <0.1 ppm

Max. operating temperature: 113°F. (45°C.)

Ph range: 2-11

Max. feed water turbidity: 1 NTU

Membrane style: Dry

Variants

Code Description

090017-050 Ionicore USmotic RO membrane TFC 2012 - 50GPD (25) 090017-075 Ionicore USmotic RO membrane TFC 2012 - 75GPD (25) 090017-100 Ionicore USmotic RO membrane TFC 2012 - 100GPD (25) 090017-150 Ionicore USmotic RO membrane TFC 2012 - 150GPD (25) 090017-180 Ionicore RO USmotic membrane TFC 2012 - 180GPD (25)

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA).

These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water.

Features: * High Rejection & Flow Rate * Made in the USA * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm

Type of membrane: Spiral wound

Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 µm. 2. Polysulfone 40 µm. 3. Non woven fabric polyester 120 µm.

Spacer: EPDM

Active surface: 50 GPD 0.35 m2 (3.8 sq. ft) 75 GPD 0.35 m2 (3.8 sq. ft) 100 GPD 0.52 m2 (5.6 sq. ft) 150 GPD 0.58 m2 (6.2 sq. ft) 180 GPD 0.64 m2 (6.9 sq. ft)

TFC Nominal Rejection Characteristics:

Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98%

The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water.

WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.

Code: 090026

Ionicore Keypra RO membranes TFC 1812/2012 - 50, 75, 100, 150, 200 GPD (25)

Features

Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day) Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day) Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day) Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day) Permeate flow rate (+/-20%) 200: 200 Gpd (757 lt./day) Minimum salt rejection: 97% Stabilized salt rejection: 98% Operating pressure test: 60 PSI TDS feed test: Tap Water (from 250 to 700 ppm) Water temperature test: Recovery test: 77°F. (25°C.) 15%

Max. operating pressure: Max. feed SDI: Max. feed flow rate: 125 PSIG / 0.86 MPa (8,6 Bar) 5 (15 min) 2 gal./min. (7,57 lt./min.)

Chlorine tolerance: <0.1 ppm

Max. operating temperature: 113°F. (45°C.)

Ph range: 2-11

Max. feed water turbidity: 1 NTU

Membrane style: Dry

Variants

Code Description

090026-050 Ionicore Keypra RO membrane TFC 1812 - 50GPD (25) 090026-075 Ionicore Keypra RO membrane TFC 1812 - 75GPD (25) 090026-100 Ionicore Keypra RO membrane TFC 2012 - 100GPD (25) 090026-150 Ionicore Keypra RO membrane TFC 2012 - 150GPD (25) 090026-200 Ionicore Keypra RO membrane TFC 2012 - 200GPD (25)

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA).

These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 200 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water.

Features: * High Rejection & Flow Rate * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm

Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 µm. 2. Polysulfone 40 µm. 3. Non woven fabric polyester 120 µm.

Spacer: EPDM

Active surface: 50 GPD 0.37 m2 (3.9 sq. ft) 75 GPD 0.40 m2 (4.3 sq. ft) 100 GPD 0.40 m2 (4.3 sq. ft) 150 GPD 0.58 m2 (6.2 sq. ft) 200 GPD 0.77 m2 (8.2 sq. ft)

TFC Nominal Rejection Characteristics: Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98%

The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water.

WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for

that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months. Code: 090025

Ionicore Keypra RO membranes TFC 3012/3013 - 300, 400 GPD (9)

Features

Permeate flow rate (+/-20%) 300: 300 Gpd (1.135 lt./day)

Permeate flow rate (+/-20%) 400: 400 Gpd (1.514 lt./day)

Minimum salt rejection: 97%

Stabilized salt rejection: 97%

Operating pressure test: 100 PSI

TDS feed test: 250 ppm

Water temperature test: 77°F. (25°C.)

Recovery test: 15%

Max. operating pressure: 300 PSIG / 2.06 MPa (20,6 Bar)

Max. feed SDI:

Max. feed flow rate: 5 (15 min) 2 gal./min. (7,57 lt./min.)

Chlorine tolerance: <0.1 ppm

Max. operating temperature: 113°F. (45°C.)

Ph range: 3-10

Max. feed water turbidity: 1 NTU

Membrane style: Dry

Variants

Code Description

090025-300 Ionicore Keypra RO membrane TFC 3012 - 300GPD (9) 090025-400 Ionicore Keypra RO membrane TFC 3013 - 400GPD (9)

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA).

These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 400 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water.

Features: * High Rejection & Flow Rate * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm

Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 µm. 2. Polysulfone 40 µm. 3. Non woven fabric polyester 120 µm.

Spacer: EPDM

Active surface: 300 GPD 1.14 m2 (12.3 sq. ft) 400 GPD 1.42 m2 (15.3 sq. ft)

TFC Nominal Rejection Characteristics: Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98%

The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water.

WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in

your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months. Code: 090019

Pentair RO encapsulated membranes TLC GRO 36, 50, 75 GPD (16)

Variants

Code Description

090019-01 Pentair RO encapsulated membrane TLC GRO-36EN GPD (16) 090019-02 Pentair RO encapsulated membrane TLC GRO-50EN GPD (16) 090019-03 Pentair RO encapsulated membrane TLC GRO-75EN GPD (16)

GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high quality reverse osmosis water while wasting 3 times less water to the drain.

Features * TLC Thin Layer Composite membrane. * 100% dry membrane maximizing shelf life. * Double the recovery over standard RO elements. * High rejection stability at high input TDS. * Maximal Pressure: 6.90 bar. * Maximal Temperature: 49°C. * pH: 4-11. * Free Chlorine: 0.1 ppm.

Connections: * Inlet water: 1/4" Quick Fit.. * Outlet permeate: 1/4" Quick Fit. * Drain: 1/4" Quick Fit.

Benefits * 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO) * High performances even under extreme conditions. * Membrane can be stored for a longer period of time.

Nominal performance GRO-36EN * Flow* Gpd (Lpd): 36 (136.3); * Rejection: 96%; * Drain flow control (ml./min.): 100.

Nominal performance GRO-50EN * Flow* Gpd (Lpd): 50 (189.3); * Rejection: 96%; * Drain flow control (ml./min.): 150.

Nominal performance GRO-75EN * Flow* Gpd (Lpd): 75 (283.9); * Rejection:96%; * Drain flow control (ml./min.): 200.

Nota bene: The data above is based on internal laboratory testing. * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 50% recovery after 24 hours. Individual element flux may vary ± 15%. The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against NSF/ANSI Standard 58 for materials and structural integrity requirements.

Here is the expected amount of water saved each year, for a family of 4 people: Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt. Standard RO membrane: 17’520 lt. of rejected water. GRO membrane: 4’380 lt. of rejected water. The use of GRO membranes allows a saving of about 13’000 lt. of water per year. Code: 090012

Pentair RO membranes TLC 50, 75, 100 GPD (25)

Variants

Code Description

090012-050 Pentair RO membrane TLC - 50GPD (25) 090012-075 Pentair RO membrane TLC - 75GPD (25) 090012-100 Pentair RO membrane TLC - 100GPD (25)

TLC™ RESIDENTIAL RO MEMBRANES The best way to assess the overall filtration quality of a RO system is made by measuring the rejection, which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the rejection, the better the membrane performs. The recovery of a RO system represents the quantity of permeate produced compared with the quantity of concentrate rejected to the drain. The higher the recovery, the lower the rejection is.

RO MEMBRANE’S CONSTRUCTION The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around a perforated central tube. Purified water passes through the membrane and is collected in the permeate collection material while rejected impurities stay in the feed channel spacer.

TLC™ RANGE TLC™ (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any types of needs from the customer. Dimensions of these membranes are standard; they will fit into any reverse osmosis systems from the market.

FEATURES • TLC Thin Layer Composite membrane • 100% dry membrane maximizing shelf life • High rejection stability at high input TDS • Standard dimensions: can be fitted in any RO systems • Maximal Pressure: 6.90 bar • Maximal Temperature: 49°C • pH: 4-11 • Hardness: 17°F • Free Chlorine: 0.1 ppm

NOMINAL PERFORMANCE TLC-50 • Flow* Gpd (Lpd): 50 (189.3)

NOMINAL PERFORMANCE TLC-75 • Flow* Gpd (Lpd): 75 (283.9)

NOMINAL PERFORMANCE TLC-100 • Flow* Gpd (Lpd): 100 (378.5)

* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 15% recovery after 24 hours. Individual element flux may vary ± 15%.

BENEFITS OF TLC™ MEMBRANES 100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag. We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost endless!

HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS Whatever the amount of total dissolved solids from the inlet water, TLC™ membranes will always give optimal performances. When compared with a membrane from competition, we can clearly see that Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at 1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**.

**Results obtained from internal testing (more testing results are available upon request)

NSF CERTIFIED Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will save time and money during the NSF certification process of the complete RO system by the OEM.

NSF COMPONENT The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS

IMPORTANT INFORMATION Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC Membranes are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane element performance can be affected by fluctuations in water quality. Code: 090007

AMI RO membranes TFC 1812/3012 100, 150, 300 GPD (25)

090007-100 AMI RO membrane TFC 1812 - 100GPD (25) 090007-150 AMI RO membrane TFC 1812 - 150GPD (25) 090007-300 AMI RO membrane TFC 3012 - 300GPD (25)

AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality.

Recommended Operating Conditions (50, 75, 100, 150gpd) * Maximum operating pressure: 125 psi (8,61bar) * Maximum feed flow rate: 2 gpm (7,57lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 5 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Minimum brine flow to permeate flow ratio: 4:1 * Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm) * Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm) Note: Salt rejection and performance specifications shown are from internal test data. Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C) feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%.

The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits loosely, you may need to wrap a few layers of tape near one end to make a tight fit.

Recommended Operating Conditions (300gpd) * Maximum operating pressure: 300 psi (20,68bar) * Maximum feed flow rate: 6 gpm (22,71lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Single Element recovery: 15% * Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm) Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8 and 10% recovery. Element permeate flow may vary ± 15%. Code: 090006

NF90-2012 nanofiltration RO membrane - 180GPD (25)

ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide composite membrane elements display an outsdanding salt rejection of more than 97% , superior product water flow , high thermal and pressure durability , wide tolerance of chlorine and PH.

SPECIFICATIONS OF PRODUCT Membrane 180GPD Cod. 090006-01 NF90-2012 NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD

Test condition Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm * Recovery: 15%

Operating limits Max. temperature 40ºC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) * Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm

Caution Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to stabilized

Code: 090002

Housings 2,5" for reverse osmosis membrane 1812, 2012 - 50, 75, 100, 150, 180 GPD

Variants

Code Description

090002-06 Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure 1/8" (20) 090002-04 Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure double o-ring 1/8" (40) 090002-03 1812, 2012 Housing Wrench for cod. 090002-04

With double o-ring.

Code: 090021

Vessel for reverse osmosis membrane 3012 - 300GPD

Code: 090027

Vessel for reverse osmosis membrane 3012 - 300GPD quick fittings connections clips

Variants

Code Description

090027-01 Vessel for reverse osmosis membrane 3012 - 300GPD quick fittings connections clips

Connections * Inlet: 3/8" * Outlet/Drain: 1/4"

Code: 090014

Yarn Home RO membrane TFC 3013 - 400 GPD (1)

Code: 090015

Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips

Variants

Code Description

090015-01 Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips 090015-02 3013 vessel wrench for cod. 090015-01

Code: 090022

Vessel for reverse osmosis membrane 3013 - 400GPD

Connections * Inlet: 1/4" * Outlet/Drain: 1/8"

Code: 090023

Ionicore RO membranes TFC LP2521, LP2540, LP4040 Medium pressure

Features

Permeate flow rate (+/-20%) LP2521: 300 gal./giorno (1.135 lt./giorno)

Permeate flow rate (+/-20%) LP2540: 750 gal./giorno (2.839 lt./giorno)

Permeate flow rate (+/-20%) LP4040: 2.500 gal./giorno (9.463 lt./giorno)

Minimum salt rejection: 98%

Stabilized salt rejection: 99%

Operating pressure test: 150 PSI (10,3 Bar)

TDS feed test: 1500 ppm

Water temperature test: 77°F. (25°C.)

Recovery test: 15%

Ph test: 7,5

Max. operating pressure: 600 PSIG / 4.23 MPa (42,3 Bar)

Max. feed SDI: 5 (15 min)

Max. feed flow rate: 16 gal./min. (60,55 lt./min.)

Chlorine tolerance: <0.1 ppm

Max. operating temperature: 113°F. (45°C.)

Ph range: 3-10

Variants

Code Description

090023-02 Ionicore RO membrane TFC LP2521 Medium pressure 090023-03 Ionicore RO membrane TFC LP2540 Medium pressure 090023-04 Ionicore RO membrane TFC LP4040 Medium pressure

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to

These R.O. TFC(thin film composite) membranes are available with different flow rates. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. m174/2004 (Italian Ministerial Decree).The membrane remove up to 99% of total dissolved solids (TDS), delivering healthier and safer drinking water.

Features: * ISO 9001:2008 Certified * Max. inlet Hardness: 5°F. (50ppm) * Max. Free Chlorine: 0.1 ppm

Active surface: TFC LP2521: 1,3 m2 (14 sq. ft) TFC LP2540: 2,6 m2 (28 sq. ft) TFC LP4040: 8,4 m2 (90 sq. ft)

TFC Nominal Rejection Characteristics: Calcium: 99% Sodium: 99% Magnesium: 99% Potassium: 98% Manganese: 99% Iron: 99% Aluminum: 99% Copper: 99% Nickel: 99% Cadmium: 99% Silver: 99% Zinc: 99% Mercury: 99% Radioactivity: 98-99,3% Chloride: 95-97% Ammonium: 88-97% Bromide: 94-96% Phosphate: >99% Chromate: 90-98% Cyanide: 90-97% Sulfate: 85-99% Thiosulfate: 96-99% Silicate: 95-97% Silica: 80-98% Nitrate: 93-96% Boron: 80-86% Borate: 35-70% Fluoride: 94-96% Polyphosphate: >99% Orthophosphate: 98-99% Chromate: 90-98% Virus and Bacteria:100%

The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water.

Code: 090013

Greenfilter RO membranes TFC LP2514, LP2521, LP2540, LP4040 Medium pressure

Variants

Code Description

090013-04 Greenfilter RO membrane TFC LP2514 Medium pressure 090013-01 Greenfilter RO membrane TFC LP2521 Medium pressure 090013-02 Greenfilter RO membrane TFC LP2540 Medium pressure 090013-03 Greenfilter RO membrane TFC LP4040 Medium pressure

Code: 090024

Ionicore housings 2,5" and 4" for reverse osmosis membranes 2514, 2521, 2540, 4040x1 - 300psi SS304, FRP

Variants

Code Description

090024-01 Ionicore housing 2,5" for R.O. membrane 2514x1 - 300psi SS304 090024-02 Ionicore housing 2,5" for R.O. membrane 2521x1 - 300psi SS304 090024-03 Ionicore housing 2,5" for R.O. membrane 2540x1 - 300psi SS304 090024-04 Ionicore housing 4" for R.O. membrane 4040x1 - 300psi SS304 090024-10 Ionicore housing 2,5" for R.O. membrane 2514x1 - 300psi FRP 090024-11 Ionicore housing 2,5" for R.O. membrane 2521x1 - 300psi FRP 090024-12 Ionicore housing 2,5" for R.O. membrane 2540x1 - 300psi FRP 090024-13 Ionicore housing 4" for R.O. membrane 4040x1 - 300psi FRP

Code: 090020

Housing 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter

Variants

Code Description

090020-02 Housing 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter

Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02

Features: * Made of fiber reinforced polyester. * Front connection, permeate the collection at both ends. * Close by blocking half-length AISI-304 easy membrane replacement. * EPDM seals. ABS collector plugs. * Compatible with standard 4 "membranes. * Support brackets included.

Connections: * Inlet: 1/2" BSP F. * Outlet/Drain: 3/4" BSP F

Technical features: * Pressure: 21 kg/cm2, 21 bar (300 psi) * Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi) * Max. temperature: 49°C (120.2°F) * Min. temperature: -10°C (14°F) * pH range, continuous operation: 3-11 * pH range, short-term cleaning: 2-12 (max 30 min.) * Weight: 6 kg