Membranes Catalog

Page 1


INDEX Membranes............................................................................................................................................................. 3


Membranes Code: 090001

Filmtec membrane TFC TW30 1812 - 50, 75, 100 GPD (25)

Variants Code

Description

090001-01 090001-02 090001-03

Filmtec membrane TFC TW30 1812 - 50 GPD (25) Filmtec membrane TFC TW30 1812 - 75 GPD (25) Filmtec membrane TFC TW30 1812 - 100 GPD (25)

Code: 090005

Greenfilter membrane TFC 1812/2012/3012/3013 - 50, 75, 100, 150, 180, 300, 400 GPD

Variants Code

Description

090005-50 090005-75 090005-100 090005-180 090005-300 090005-400

Greenfilter membrane TFC 1812 - 50 GPD (25) Greenfilter membrane TFC 1812 - 75 GPD (25) Greenfilter membrane TFC 1812 - 100 GPD (25) Greenfilter membrane TFC 2012 - 180 GPD (25) Greenfilter membrane TFC 3012 - 300 GPD (1) Greenfilter membrane TFC 3013 - 400 GPD (1)

Definition Reverse osmosis process is based on nature and has been used for more than 30 years. These semipermeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. Spacer: EPDM

14 January 2020

3/21


SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090005-50 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090005-75 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 100 GPD Cod. 090005-100 Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 150 GPD Cod. 090005-150 Active surface: x,xxm²(xft²) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts rejection(N2) 97,5% * Recovery del 15% Membrane 180 GPD Cod. 090005-180 Active surface: x,xxm²(xft²) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts rejection(N2) 93% * Recovery del 15% Membrane 300 GPD Cod. 090005-300 Active surface: x,xxm²(xft²) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts rejection(N2) 95% * Recovery del 15% Membrane 400 GPD Cod. 090005-400 Active surface: x,xxm²(xft²) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts rejection(N2) 95% * Recovery del 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm OPERATING LIMITS OF 150, 180, 300,400 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 8,6 bar (125 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * Free Chlorine tolerance¹ <0,1 ppm ¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION • All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite and propylene glycol to prevent biological growth in short-term storage and transport.

14 January 2020

4/21


• It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • To prevent biological growth during prolonged system shutdown, it is recommended that membrane elements be immersed in a preservative solution. • The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Code: 090018

Greenfilter encapsulated membranes TFC 50, 75, 100 GPD

Variants Code

Description

090018-01 090018-02 090018-03 090018-04

Greenfilter encapsulated membrane TFC 50 GPD Greenfilter encapsulated membrane TFC 75 GPD Greenfilter encapsulated membrane TFC 75 GPD Filmtec Greenfilter encapsulated membrane TFC 100 GPD

High efficiency, disposable encapsulate membranes. Change complete of vessel + membrane for maximum hygiene! These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. Spacer: EPDM SPECIFICATIONS OF PRODUCT Membrane 50 GPD Cod. 090018-01 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090018-02 Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15% Membrane 75 GPD Cod. 090018-03 Filmtec® Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts rejection(N2) 97% * Recovery 15%

14 January 2020

5/21


Membrane 100 GPD Cod. 090018-04 Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts rejection(N2) 97% * Recovery 15% (N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF), 15% recovery and specified applied pressure. Permeated flows for individual elements may vary +/- 15%. (N2) Minimum SALT rejection is 95% Connections: * Inlet water: O.D. stem Ø 3/8" * Outlet permeate: O.D. stem Ø 1/4" * Drain: O.D. stem Ø 1/4" OPERATING LIMITS OF 50, 75, 100 GPD * Max. temperature 45ºC (113ºF) * Max. pressure 21 bar (300 psi) * Max. P for element 1 bar (15 psi) * Max feed flow rate 7,6 lpm (2.0 gpm) * pH range, continuous operation 3 - 10 * pH range, short-term cleaning (30 min) 2 - 11 * Max. Feed SDI 5 * Free Chlorine tolerance¹ <0,1 ppm ¹Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. We recommend removing residual free chlorine by pre-treatment prior to membrane exposure. We recommend replacing it every 24 months max. GENERAL INFORMATION • It is suggested that firs hour of pure water to be rejected. • Keep elements moist after initial wetting. • The membrane has a certain short-term resistance against chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided. • The customer is fully responsible for effects of incompatible chemicals and lubricants on elements. • Use just glycerine as a lubricant if is needed. • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design and on the operation and maintenance of the system. Note: The polluting agents removed or reduced by this system are not necessarily in your water. Code: 090017

Ionicore membrane TFC 2012 - 50, 75, 100, 150, 180 GPD (25)

Features Permeate flow rate (+/-20%) 50: Permeate flow rate (+/-20%) 75: Permeate flow rate (+/-20%) 100:

14 January 2020

50 Gpd (190 lt./day) 75 Gpd (284 lt./day) 100 Gpd (379 lt./day)

6/21


Permeate flow rate (+/-20%) 150: Permeate flow rate (+/-20%) 180: Minimum salt rejection: Stabilized salt rejection: Operating pressure test: TDS feed test: Water temperature test: Recovery test: Max. operating pressure: Max. feed SDI: Max. feed flow rate: Chlorine tolerance: Max. operating temperature: Ph range: Max. feed water turbidity: Membrane style:

150 Gpd (568 lt./day) 180 Gpd (681 lt./day) 96% 98% 65 PSI Tap Water (from 450 to 700 ppm) 77°F. (25°C.) 15% 125 - 300 PSIG 5 (15 min) 2 gal./min. (7,57 lt./min.) <0.1 ppm 113°F. (45°C.) 2-11 1 NTU Dry

Variants Code

Description

090017-050 090017-075 090017-100 090017-150 090017-180

Ionicore USmotic membrane TFC 2012 - 50GPD (25) Ionicore USmotic membrane TFC 2012 - 75GPD (25) Ionicore USmotic membrane TFC 2012 - 100GPD (25) Ionicore USmotic membrane TFC 2012 - 150GPD (25) Ionicore USmotic membrane TFC 2012 - 180GPD (25)

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * High Rejection & Flow Rate * Made in the USA * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 µm. 2. Polysulfone 40 µm. 3. Non woven fabric polyester 120 µm. Spacer: EPDM Active surface: 50 GPD 0.35 m2 (3.8 sq. ft) 75 GPD 0.35 m2 (3.8 sq. ft) 100 GPD 0.52 m2 (5.6 sq. ft) 150 GPD 0.58 m2 (6.2 sq. ft) 180 GPD 0.64 m2 (6.9 sq. ft) TFC Nominal Rejection Characteristics:

14 January 2020

7/21


Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.

14 January 2020

8/21


Code: 090025

Ionicore membrane TFC 3012/3013 - 300, 400 GPD (1)

Features Permeate flow rate (+/-20%) 300: Permeate flow rate (+/-20%) 400: Minimum salt rejection: Stabilized salt rejection: Operating pressure test: TDS feed test: Water temperature test: Recovery test: Max. operating pressure: Max. feed SDI: Max. feed flow rate: Chlorine tolerance: Max. operating temperature: Ph range: Max. feed water turbidity: Membrane style:

300 Gpd (1.135 lt./day) 400 Gpd (1.514 lt./day) 97% 97% 100 PSI 250 ppm 77°F. (25°C.) 15% 300 PSIG / 2.06 MPa (20,6 Bar) 5 (15 min) 2 gal./min. (7,57 lt./min.) <0.1 ppm 113°F. (45°C.) 3-10 1 NTU Dry

Variants Code

Description

090025-300 090025-400

Ionicore membrane TFC 3012 - 300GPD (1) Ionicore membrane TFC 3013 - 400GPD (1)

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * High Rejection & Flow Rate * ISO 9001:2008 Certified * Standard dimensions: can be fitted in any RO systems * Max. inlet Hardness: 25°F. (250ppm) * Max. Free Chlorine: 0.1 ppm Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.2 µm. 2. Polysulfone 40 µm.

14 January 2020

9/21


3. Non woven fabric polyester 120 Âľm. Spacer: EPDM Active surface: 300 GPD 1.14 m2 (12.3 sq. ft) 400 GPD 1.42 m2 (15.3 sq. ft) TFC Nominal Rejection Characteristics: Calcium: 93-98% Sodium: 92-98% Magnesium: 93-98% Potassium: 92-96% Manganese: 96-98% Iron: 96-98% Aluminum: 96-98% Copper: 96-98% Nickel: 96-98% Cadmium: 93-97% Silver: 93-96% Zinc: 96-98% Mercury: 94-97% Hardness Ca & Mg: 93-97% Radioactivity: 93-97% Chloride: 92-95% Ammonium: 80-90% Bromide: 90-95% Phosphate: 95-98% Chromate: 85-95% Cyanide: 85-95% Sulfate: 96-98% Thiosulfate: 96-98% Silicate: 92-95% Silica: 80-90% Nitrate: 90-95% Boron: 50-70% Borate: 30-50% Fluoride: 92-95% Polyphosphate: 96-98% Orthophosphate: 96-98% Chromate: 85-95% Virus and Bacteria: 99% + Lead: 95-98% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. WARNING The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.

14 January 2020

10/21


Code: 090019

Pentair GRO encapsulated membranes TLC 36, 50, 75 GPD (16)

Variants Code

Description

090019-01 090019-02 090019-03

Pentair GRO-36EN GPD encapsulated membranes Pentair GRO-50EN GPD encapsulated membranes Pentair GRO-75EN GPD encapsulated membranes

GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high quality reverse osmosis water while wasting 3 times less water to the drain. Features * TLC Thin Layer Composite membrane * 100% dry membrane maximizing shelf life * Double the recovery over standard RO elements * High rejection stability at high input TDS * Maximal Pressure: 6.90 bar * Maximal Temperature: 49°C * pH: 4-11 * Free Chlorine: 0.1 ppm Connections: * Inlet water: 1/4" Quick Fit * Outlet permeate: 1/4" Quick Fit * Drain: 1/4" Quick Fit Benefits * 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO ) * High performances even under extreme conditions * Membrane can be stored for a longer period of time Nominal performance GRO-36EN * Flow* Gpd (Lpd): 36 (136.3) * Rejection: 96% * Drain flow control (ml./min.): 100 Nominal performance GRO-50EN * Flow* Gpd (Lpd): 50 (189.3) * Rejection: 96% * Drain flow control (ml./min.): 150 Nominal performance GRO-75EN * Flow* Gpd (Lpd): 75 (283.9) * Rejection:96% * Drain flow control (ml./min.): 200

14 January 2020

11/21


Note: The data above is based on internal laboratory testing. * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 50% recovery after 24 hours. Individual element flux may vary ± 15%. The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against NSF/ANSI Standard 58 for materials and structural integrity requirements. Here is the expected amount of water saved each year, for a family of 4 people: Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt. Standard RO membrane: 17’520 lt. of rejected water GRO membrane: 4’380 lt. of rejected water The use of GRO membranes allows a saving of about 13’000 lt. of water per year. Code: 090012

Pentair membrane TLC 50, 75, 100 GPD (25)

Variants Code

Description

090012-050 090012-075 090012-100

Pentair membrane TLC - 50GPD (25) Pentair membrane TLC - 75GPD (25) Pentair membrane TLC - 100GPD (25)

TLC™ RESIDENTIAL RO MEMBRANES The best way to assess the overall filtration quality of a RO system is made by measuring the rejection, which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the rejection, the better the membrane performs. The recovery of a RO system represents the quantity of permeate produced compared with the quantity of concentrate rejected to the drain. The higher the recovery, the lower the rejection is. RO MEMBRANE’S CONSTRUCTION The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around a perforated central tube. Purified water passes through the membrane and is collected in the permeate collection material while rejected impurities stay in the feed channel spacer. TLC™ RANGE TLC™ (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any types of needs from the customer. Dimensions of these membranes are standard; they will fit into any reverse osmosis systems from the market. FEATURES • TLC Thin Layer Composite membrane • 100% dry membrane maximizing shelf life • High rejection stability at high input TDS • Standard dimensions: can be fitted in any RO systems • Maximal Pressure: 6.90 bar • Maximal Temperature: 49°C • pH: 4-11 • Hardness: 17°F • Free Chlorine: 0.1 ppm

14 January 2020

12/21


• Rejection*: 98% NOMINAL PERFORMANCE TLC-50 • Flow* Gpd (Lpd): 50 (189.3) NOMINAL PERFORMANCE TLC-75 • Flow* Gpd (Lpd): 75 (283.9) NOMINAL PERFORMANCE TLC-100 • Flow* Gpd (Lpd): 100 (378.5) * Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 15% recovery after 24 hours. Individual element flux may vary ± 15%. BENEFITS OF TLC™ MEMBRANES 100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag. We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost endless! HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS Whatever the amount of total dissolved solids from the inlet water, TLC™ membranes will always give optimal performances. When compared with a membrane from competition, we can clearly see that Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at 1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**. **Results obtained from internal testing (more testing results are available upon request) NSF CERTIFIED Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will save time and money during the NSF certification process of the complete RO system by the OEM. NSF COMPONENT The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS IMPORTANT INFORMATION Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC Membranes are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane element performance can be affected by fluctuations in water quality. Code: 090007

AMI membrane TFC 1812/3012 100, 150, 300 GPD (25)

14 January 2020

13/21


Variants Code

Description

090007-100 090007-150 090007-300

AMI membrane TFC 1812 - 100GPD (25) AMI membrane TFC 1812 - 150GPD (25) AMI membrane TFC 3012 - 300GPD (25)

AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality. Recommended Operating Conditions (50, 75, 100, 150gpd) * Maximum operating pressure: 125 psi (8,61bar) * Maximum feed flow rate: 2 gpm (7,57lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 5 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Minimum brine flow to permeate flow ratio: 4:1 * Dimensions: 50, 75, 100gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,75"(4,57cm) * Dimensions: 150gpd L-11,75"(29,85cm) I-10"(25,4cm) D-1,95"(5cm) Note: Salt rejection and performance specifications shown are from internal test data. Performance specifications based on 500 ppm tap water, 50 psi (3,44bar) applied pressure, 77°F (25°C) feed water temperature, feed water pH 7-8 and 15% recovery. Element permeate flow may vary ± 20%. The 150 gpd membranes are designed for a tight fit in most standard housings. If the membrane fits loosely, you may need to wrap a few layers of tape near one end to make a tight fit. Recommended Operating Conditions (300gpd) * Maximum operating pressure: 300 psi (20,68bar) * Maximum feed flow rate: 6 gpm (22,71lt./min.) * Maximum operating temperature: 113°F (45°C) * Maximum feed water turbidity: 1 NTU * Maximum feed water silt density index (15 min): 4 * Chlorine tolerance: <0.1 ppm * Feed water pH range, Continuous Operation: 2-11 * Feed water pH range, Short-Term Cleaning (30 minutes): 1-12 * Single Element recovery: 15% * Dimensions: 300gpd A-11,75"(29,85cm) B-10,25"(26,03cm) C-3"(7,61cm) E-3,2"(8,12cm) Note: Note: Performance specifications based on, Tap Water, 77°F (25°C) feed water temperature, pH 8 and 10% recovery. Element permeate flow may vary ± 15%. Code: 090006

NF90-2012 nanofiltration membrane - 180 GPD (25)

14 January 2020

14/21


Variants Code

Description

090006-01

NF90-2012 nanofiltration membrane - 180 GPD (25)

ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide composite membrane elements display an outsdanding salt rejection of more than 97% , superior product water flow , high thermal and pressure durability , wide tolerance of chlorine and PH. SPECIFICATIONS OF PRODUCT Membrane 180GPD Cod. 090006-01 NF90-2012 NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD Test condition Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm * Recovery: 15% Operating limits Max. temperature 40ºC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) * Operating PH range: 4-11 * Chlorine tolerance <0,1 ppm Caution Should not be storage in direct sunlight * The flux and rejection performance may take 24 to 48 hours to stabilized Code: 090002

Housings 2,5" for reverse osmosis membrane 1812, 2012 - 50, 75, 100, 150, 180GPD (25)

Variants Code

Description

090002-06 090002-04 090002-03

Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure 1/8" (20) Housings 2,5" for reverse osmosis membrane 1812, 2012 high pressure double o-ring 1/8" (40) 1812, 2012 Housing Wrench for cod. 090002-04

With double o-ring. Code: 090011

Housings for reverse osmosis membrane 3012 - 300GPD Greenfilter (1)

14 January 2020

15/21


Connections * Inlet: 1/8" * Outlet/Drain: 1/8" Code: 090021

Vessel for reverse osmosis membrane 3012 - 300GPD

Connections * Inlet: 1/4" * Outlet/Drain: 1/8" Code: 090014

Yarn Home membrane TFC 3013 - 400 GPD (1)

Code: 090015

Vessel for reverse osmosis membrane 3013 - 400GPD quick fittings connections clips

Connections * Inlet: 3/8" * Outlet/Drain: 1/4"

14 January 2020

16/21


Code: 090022

Vessel for reverse osmosis membrane 3013 - 400GPD

Connections * Inlet: 1/4" * Outlet/Drain: 1/8" Code: 090016

Vessel for reverse osmosis membrane 3013 - 400GPD

Connections * Inlet: 3/8" * Outlet/Drain: 1/4" Code: 090023

Ionicore membrane TFC LP2521, LP2540, LP4040 Medium pressure

Features Permeate flow rate (+/-20%) LP2521: Permeate flow rate (+/-20%) LP2540: Permeate flow rate (+/-20%) LP4040: Minimum salt rejection: Stabilized salt rejection: Operating pressure test: TDS feed test: Water temperature test: Recovery test:

14 January 2020

300 gal./giorno (1.135 lt./giorno) 750 gal./giorno (2.839 lt./giorno) 2.500 gal./giorno (9.463 lt./giorno) 98% 99% 150 PSI (10,3 Bar) 1500 ppm 77°F. (25°C.) 15%

17/21


Ph test: Max. operating pressure: Max. feed SDI: Max. feed flow rate: Chlorine tolerance: Max. operating temperature: Ph range:

7,5 600 PSIG / 4.23 MPa (42,3 Bar) 5 (15 min) 16 gal./min. (60,55 lt./min.) <0.1 ppm 113°F. (45°C.) 3-10

Variants Code

Description

090023-02 090023-03 090023-04

Ionicore membrane TFC LP2521 Medium pressure Ionicore membrane TFC LP2540 Medium pressure Ionicore membrane TFC LP4040 Medium pressure

The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available with different flow rates. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. m174/2004 (Italian Ministerial Decree).The membrane remove up to 99% of total dissolved solids (TDS), delivering healthier and safer drinking water. Features: * ISO 9001:2008 Certified * Max. inlet Hardness: 5°F. (50ppm) * Max. Free Chlorine: 0.1 ppm Active surface: TFC LP2521: 1,3 m2 (14 sq. ft) TFC LP2540: 2,6 m2 (28 sq. ft) TFC LP4040: 8,4 m2 (90 sq. ft) TFC Nominal Rejection Characteristics: Calcium: 99% Sodium: 99% Magnesium: 99% Potassium: 98% Manganese: 99% Iron: 99% Aluminum: 99% Copper: 99% Nickel: 99% Cadmium: 99% Silver: 99% Zinc: 99% Mercury: 99% Radioactivity: 98-99,3% Chloride: 95-97% Ammonium: 88-97% Bromide: 94-96% Phosphate: >99% Chromate: 90-98% Cyanide: 90-97% Sulfate: 85-99% Thiosulfate: 96-99% Silicate: 95-97% Silica: 80-98% Nitrate: 93-96%

14 January 2020

18/21


Boron: 80-86% Borate: 35-70% Fluoride: 94-96% Polyphosphate: >99% Orthophosphate: 98-99% Chromate: 90-98% Virus and Bacteria:100% The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water. Code: 090013

Greenfilter membrane TFC LP2514, LP2521, LP2540, LP4040 Medium pressure

Variants Code

Description

090013-04 090013-01 090013-02 090013-03

Greenfilter membrane TFC LP2514 Medium pressure Greenfilter membrane TFC LP2521 Medium pressure Greenfilter membrane TFC LP2540 Medium pressure Greenfilter membrane TFC LP4040 Medium pressure

Code: 090024

Ionicore Housings 2,5" and 4" for reverse osmosis membranes 2514, 2521, 2540, 4040x1 - 300psi SS304, FRP

Variants Code

Description

090024-01 090024-02 090024-03 090024-04 090024-10 090024-11 090024-12 090024-13

Ionicore Housing 2,5" for R.O. membrane 2514x1 - 300psi SS304 Ionicore Housing 2,5" for R.O. membrane 2521x1 - 300ps SS304 Ionicore Housing 2,5" for R.O. membrane 2540x1 - 300psi SS304 Ionicore Housing 4" for R.O. membrane 4040x1 - 300psi SS304 Ionicore Housing 2,5" for R.O. membrane 2514x1 - 300psi FRP Ionicore Housing 2,5" for R.O. membrane 2521x1 - 300psi FRP Ionicore Housing 2,5" for R.O. membrane 2540x1 - 300psi FRP Ionicore Housing 4" for R.O. membrane 4040x1 - 300psi FRP

14 January 2020

19/21


Code: 090020

Housings 4" for reverse osmosis membrane 4040x1 - 300psiEP Greenfilter

Variants Code

Description

090020-02

Housings 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter

Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02 Features: * Made of fiber reinforced polyester. * Front connection, permeate the collection at both ends. * Close by blocking half-length AISI-304 easy membrane replacement. * EPDM seals. ABS collector plugs. * Compatible with standard 4 "membranes. * Support brackets included. Connections: * Inlet: 1/2" BSP F. * Outlet/Drain: 3/4" BSP F Technical features: * Pressure: 21 kg/cm2, 21 bar (300 psi) * Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi) * Max. temperature: 49째C (120.2째F) * Min. temperature: -10째C (14째F) * pH range, continuous operation: 3-11 * pH range, short-term cleaning: 2-12 (max 30 min.) * Weight: 6 kg

14 January 2020

20/21


Powered by TCPDF (www.tcpdf.org)


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.