CMSS 9100 Single shield twisted pair cable
CMSS 9200 Double shield twisted pair cable ‌
Description CMSS 9100 is a single shielded, single twisted pair cable with the conductors individually insulated with Dupont FEP Teflon, a braided shield with drain wire and an outer insulated jacket also made of clear Dupont FEP Teflon. The cable is wrapped with a color tape under the outer insulated jacket and also has super imposed on the color tape a white marker tape with cable designation and SKF logo. CMSS 9200 is a double shielded, single twisted pair cable with the conductors individually insulated with Dupont FEP Teflon, an inner shield of aluminum polyester foil with drain wire, an inner insulated jacket of Dupont FEP Teflon, a braided outer shield and the outer insulated jacket of clear Dupont FEP Teflon. The cable is wrapped with a color tape under the outer insulated jacket and also has super imposed on the color tape a white marker tape with cable designation and SKF logo.
Recommended uses The single shield cable is recommended for use with sensors in normal industrial applications where historically these type cables have been previously used and installed. The double shield cable is highly recommended for use with sensors in industrial installations where there is a high noise field with one such example being machine tools and another being power generating facilities.
CMSS 9100 Single Shield Twisted Pair Cable CMSS 9200 Double Shield Twisted Pair Cable
Specifications (applicable to both models)
Ordering information
Conductors: Tin plated copper, 19 x 32 strands, size 20 AWG (American Wire Gauge)
• CMSS 9100-500 2-conductor, twisted pair, single shield cable with continuous cable length, 150 meters (500 feet spool).
Color code: Black and white pair, cable color is yellow with white SKF label Outer jacket diameter: 0.190” ± 0.005”, includes glass fillers for roundness Wire materials: All conductors, drain wires and braided shields are of tin plated copper Capacitance: Approximately 89 pF/m (27 pF/ft) Voltage rating: 600 V RMS Working temperature range: -80 °C to +200 °C (-112 °F to +392 °F) Heat and flame resistance: Meets requirements of UL 910 Stiner Tunnel test
For additional information on SKF Reliability Systems products, contact:
SKF Reliability Systems
5271 Viewridge Court • San Diego, California 92123 USA Telephone: +1 858-496-3400 • FAX: +1 858-496-3531 Web Site: www.skf.com/cm • ® SKF is a registered trademark of the SKF Group. • All other trademarks are the property of their respective owners. © SKF Group 2008 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. SKF reserves the right to alter any part of this publication without prior notice. SKF Patents include: #US04768380 • #US05679900 • #US05845230 • #US05854553 • #US05992237 • #US06006164 • #US06199422 • #US06202491 • #US06275781 • #US06489884 • #US06513386 • #US06633822 • #US6,789,025 • #US6,792,360 • US 5,633,811 • US 5,870,699 • #WO_03_048714A1 Publication CM2240 EN (Revised 4-08) • Printed in the United States of America
• CMSS 9100-1000 2-conductor, twisted pair, single shield cable with continuous cable length, 300 meters (1,000 feet spool). • CMSS 9200-500 2-conductor, twisted pair, double shield cable with continuous cable length, 150 meters (500 feet spool).