IG Limited is part of the The information contained in this brochure was accurate at the date of going to press. The Company, however, reserves the right, while maintaining the essential performance of the lintels described, to introduce at any time modifications and changes of details as may be considered necessary to improve the products described. Every endeavour will be made to bring this brochure up-to-date at regular intervals, but in order to avoid any misunderstanding, any person interested should enquire of the Company as to whether there have been any material alterations since the date of this publication.
(31.9)
Part of the
Xh2
LINTELLIGENCE Forty years of successfully meeting the lintel needs
Features
of specifiers and contractors has taught us to take
C O N T E N T S INTRODUCTION
2
CONTENTS
3
PRODUCT GUIDE
4-6
nothing for granted.
•
Standard lintels for all cavity wall constructions
We have developed our comprehensive range of
•
Standard lintels for timber frame construction
standard lintels to ensure we cover all conventional
•
Special lintels designed and manufactured to specification
CAVITY WALL LINTELS
•
Complete with insulation and plaster key
THE L1 PROFILE
•
Conform to all relevant Building Regulations
STANDARD
•
Available in galvanised mild steel or stainless steel
and timber frame constructions. The range is continually evolving to take account of changing building requirements such as higher standards of insulation.
WIDE INNER LEAF
7 50-70/70-95 CAVITY
8-9
95-110/110-150 CAVITY
10-11
50-70 CAVITY
12
70-95/95-110 CAVITY
13-14
50-110 CAVITY
15
Investment in manufacturing enables us to meet a growing need for lintels of non-standard design we established our special lintels department
WIDE OUTER LEAF
specifically to satisfy those needs. L1/E EAVES LINTELS
Benefits
If our standard range does not provide the lintels you require, we will design and manufacture lintels to meet your specification.
Specifying lintels is not always straightforward, so
•
Technical advice and assistance readily available
•
Free lintel scheduling
•
Investment in manufacture to ensure consistent quality
•
Continually evolving product range to meet changing needs
•
Available through a nationwide network of specialist distributors
in the most effective and efficient manner. This includes free lintel scheduling to help ease your
STANDARD & WIDE INNER
50-100 CAVITY
17
HEAVY DUTY LINTELS
50-110 CAVITY
18
EXTRA HEAVY DUTY LINTELS
50-110 CAVITY
19
TIMBER FRAME LINTELS
we provide a range of technical advice and support services to make sure our lintels are always used
16
busy workload.
Product quality and consistency have always been
20
L7/50 TIMBER FRAME
40-55 CAVITY
21
L7/75 TIMBER FRAME
70-90 CAVITY
21
L8/50 CONCRETE INNER
50-65 CAVITY
21
SINGLE WALL LINTELS
22
L9/L10/L11
23
BOX LINTELS
24
of prime importance - that is why we have always STANDARD
75-200
24-25
HEAVY DUTY
100-200
26
ensured that our lintels meet all current standards of performance and durability. To help make sure that our lintels are as good tomorrow as they are
New Website
today, we have just updated our lintel factory with the latest machinery.
www.igltd.co.uk
INTERNAL LINTELS
27
LINTEL SOFFIT CLADDING
28
UNIVERSAL ARCH
28
STAINLESS STEEL LINTELS
29
SPECIAL LINTELS AND FAX BACK FORM
29-32
TECHNICAL INFORMATION
33-35
CAVITY TRAYS
36-37
KEYLITE ROOF WINDOWS
38-39
Finally, we have also learnt that all the above is only of value if our lintels are available when and where you want them. So our network of specialist distributors has been established to give you ready availability throughout the UK.
Now that is lintelligence - only available from IG Lintels
2
3
L1/S 50
L1/S 50 WOL
L1/S WIL 100
L1/S WIL 75
L1/S WIL 50
L1/E 50
L1/S 11
L7/50
PRODUCT GUIDE CAVITY WALL LINTEL S con t.
C AV ITY WA LL L INTE L S L1/S 50
L 1/ S 7 5
STANDARD
(also available as Stepped Lintels)
Standard L1/S 50
Page 8
L 1/ H D 50 L1/S 50
Heavy
L1/S 50 L1/S 75
Duty
L1/S 50
L1/S 50 L1/HD L1/S 50 75
L1/HD L1/S Page 875 50
L1/S 50
L1/S 100
L1/S 75
Page 12 L1/S 75
L1/S 50
L1/HD L1/S 50 100 L1/HD 75
LL1/S 1 /75S W I L 5 0
Standard
L1/S 75
WIDE INNER BLOCK/BRICK
L1/S 50
L1/S 75
(also available as Stepped Lintels)
L1/S 50
Duty
L1/S 75 L1/S 75
L1/S 100
L1/HD 50
DutyL1/HD 50 L1/HD 75 Page 12
L1/HD 75
Extra
L1/SL1/S 50 75 L1/S 100
Page 10
L1/S 100L1/S WIL 50 L1/S 75
L1/S 100 L1/S WIL 50 L1/S WIL 75
L1/S WIL 50 L1/S WIL 75 L1/S WIL 100
L 1/ H D 10 0
50 75 L 1 / X H D 7L1/HD 5 L1/HD
L1/HDL1/HD 50 75 L1/HD 100
L 1 / X H D 1L1/HD 0 0 L1/HD 75 100
L1/HD 50 75 L1/HD
L1/XHD 50 L1/S 100 L1/S WIL 50
L1/HD WIL 50
L1/HDL1/HD 50 L1/HD 100 75 L1/S WIL 75L1/HD 75 L1/HD 75 L1/XHD 50 L1/HD 100 L1/HD WIL 50
L1/HD L1/HD 75 100 L1/HD WIL 50
L1/S WIL 100 100 L1/HD 100 Page 10L1/HD WIL 75 L1/HD WIL L1/HD 50
L 1 / H D WI L 1 0 0
WIDE OUTER BLOCK/STONE
L1/XHD 50 L1/HD 75 L1/HD 100 L1/S WIL 75
L1/XHD 50 L1/HD 75 L1/S WIL 50
50 L1/HD 50 100 L1/XHD
L1/HD 100 L1/HD L1/S WIL 100 WIL 50
L1/HD 75 L1/HD 100 L1/XHD 50 L1/HD 75 L1/HD 100 L1/XHD 50 L1/HD 75 L1/S WIL 100 L1/S WIL 75 L1/HD 100 L1/HD 75 L1/HD WIL 75 L1/HD WIL 50
L 1/ E 5 0
L1/HD WIL 50
EAVES
L1/HD WIL 100
L1/HD 100
L1/HD 75
Page 15
Page 17
Standard
L1/S WIL 100
L1/HD WIL 75
L1/HD WIL 50
STANDARD
STANDARD
L1/HD WIL 100
L 5/ 5 0
L1/S 100 WOL
Heavy Duty
L1/S 75 WOL
L1/HD WIL 75
Page 18
Extra
L1/S 100 WOL L5 L5/50
L1/HD WIL 100 L6
L 6/ 5 0
L1/S 110 L7/50
L1/S 110
110 CAVITY
130 CAVITY
L1/E L1/S 7575 WOL
75 L1/EL7/75 L1/S 75 WOL
L1/E L7/75 75
L1/E 75 L1/HD WIL 100 L1/S 75 WOL
L1/E L7/75 75 L1/S 75 WOL
L1/E L7/75 75
LL1/HD 1 /SWIL1751L1/HD 0 WIL 100L1/S 75 WOL
L1/HD WIL 100
L1/HD WIL 100 L1/S 75 WOL L1/HD WIL 75
L 1 /S 13 0
Page 11
Page 11
L1/E 75 L1/EL7/75 75 L1/S 75 WOL L1/HD WIL 100L1/S 75 WOL L1/HD WIL 100 L1/S 75 WOL L1/HD WIL 75 L1/S 130 L7/75100 L1/E 75L7/50 L1/SWOL 110 L7/75 L1/S L1/S 100 WOLWIL50 L1/HD WIL L1/E L1/HD WIL 100 L1/E 75 L1/E WIL50 L1/S100 75 WOL
Page 21 L1/S 110 L7/50 L7/75 L1/E WIL50
L7/75 L1/E 75
L1/S 130 L8/50
L L1/S 1 / S1301 5 0 L1/S 130
Page 11
L1/S 130
L8/50
L1/S 130
L1/S 110 L7/50
150 CAVITY
L8/50 L1/S 130
L1/S 110
L7/75
L1/S 130
L1/S 130
L7/75
L1/S 130
L1/S 130
L7/75
L1/S 130
L1/S 150
L1/S 150
L1/HD WIL 50L1/S L1/HD WIL 75 50 WOL
Page 15
L1/HD WIL 50
L1/HD WIL 75 L1/HD WIL 100
L1/HD WIL 75 L1/E 50
Page 15
L1/HD WIL 100 L7/50
L6
L7/50 L1/S 75 WOL
L1/S 110
L1/E 75
L7/75 L1/S 100 WOL L5 L5/50
L1/E 75 L1/HD WIL L6 100 L8/50 L7/75 L1/S 100 WOL
Page 18
L 6/ 75
Lintels are identified by type, loading characteristics and cavity
L1/S 130
L1/E WIL50 L6/75
L1/E WIL50
L1/S 100 WOL L1/E WIL50
L8/50
L1/S 100 WOL L1/S 100 WOL L1/E WIL50 L1/E WIL50 L1/S 130 L1/E WIL50
L8/50
L5 L5/50
L8/50
L1/S 150
L5/75
L 5/ 10 0
L1/S 150 L1/E WIL50 L8/50 L5/75
L1/S 130
L8/50
L1/S 150
Page 18
L 6/ 10 0
L6/100
L1/S 150
L7/75
L1/HD WIL 100 L1/S 100 WOL L1/S 100 WOL L1/E WIL50 L1/S 110
L1/S 130 L1/S 130
L1/E 75
L8/50
L7/75
L6/75
L1/E 75
L1/S 100 WOL L1/E WIL50
L1/HD WIL 100 L1/S 100 WOL L7/75 L1/S 100 WOL
L5/100
L8/50 L1/S 100 WOL L1/E WIL50
L1/E WIL50L8/50 L1/S 150
requirements of intended usage. L1/S 150 L1/S 150
L8/50
L1/S 150
L1/S 150
widths with reference to the appropriate page for full details.
L1/S 100 WOL L1/E WIL50
L1/HD L1/S 100 WOLWIL 100
L1/S 130
L7/75
L 5/ 75
L1/S 50 WOL L1/HD WIL 100 L1/E 50 L1/HD WOL L1/S 110 L1/S WIL100 100 L1/HD WILWOL 75 L1/E100 WIL50 L1/S 50 L1/HD 100 L1/S 100 WOLL7/50 L1/HD WIL110 100 L1/S WIL 75 L1/HD WIL 75 L1/HD WIL 50 L1/E L1/HD WILL1/HD 50 50 L1/S L1/E L1/S 50 WOL L7/50WIL L1/S 110 50 L7/50 L1/S 130 L7/75 L1/E 75 100 WOL L8/50 L1/S L8/50 L1/S 100WIL50 WOL L1/HD WILL1/S 100 75 WOL L1/E L1/S 5075 WOL L1/HD WIL L1/S 110 L1/E WIL50 L1/E 50 L1/HD WIL 100 L7/50
L1/E 75 L7/75 L1/S 75 WOL L1/S 75 L1/E WOL75 L1/S 100 WOL L1/E WIL50 L1/E 75 L1/S 110
Page 14
L1/S 110
L8/50 L1/E WIL50 L1/S 150
L8/50 L1/S WOL L1/E100 WIL50
L1/S 1
that properties and installation of IG steel lintels meet the
L1/HD WIL 100 L1/S 75 WOL L7/50 L1/S 75 WOL
L7/50
Page 17
L1/E 75 L1/HD WIL 100
L1/S 110 L7/50
guide to IG’s range of steel lintels.
L7/75
L 1/ E 7 5
L1/E WIL50
L1/E 50
Page 21
The tables on these pages provide the specifier with a quick
L1/S 75 L1/E WOL75
L1/HD 100 L1/HD WIL 75 L1/HD WIL 50 L1/HD WIL 75 L1/HD WIL 100 L1/HD WIL 50 L1/HD WIL 75 L1/HD WIL 100 L1/HD WIL 5050 WOL L1/S L1/E 50 L7/50 L1/E 75 L1/S 110 L1/S 75 WOL L1/HD WIL 100 L1/HD WIL 75 L1/HD WIL 50 L1/HD WIL 100
L1/S 75 WOL
L1/HD 100 L1/HD WIL 100 L1/HD WIL 75 WIL 75 L1/HD WIL 50L1/S L1/HD WILL1/HD 50 50 WOL L1/EL1/S 50 75 WOL L1/HD WIL 75 WIL 5075L1/HD WILL1/HD L1/HD L1/HD WIL 75 100 WIL 50 L1/HD WIL 100 L1/HD WIL
L1/S 75 L1/E WOL75
L 1 / S 100W OWILL 751 0L1/HD 0 WIL 100 L 1 / S L1/HD W OWIL L 507 5L1/HD WIL 75L1/HD WIL 50 L1/HD WILL1/S 75 L1/HD WIL L1/HD 110
L1/E 50 L1/HD WIL 100
L1/HD WIL 75
Page 17
L1/HD WIL 100
L1/HD WIL 75
L 1 / E W I L 5 0 L1/S 50 WOL
L1/HD WIL 75
L1/HD WIL 100 L1/HD WIL 50
L1/S 75 WOL
L1/S 50 50 WOLL7/50 L1/E
L1/S 50 WOL L1/S50 50 WOL L1/S 50 L1/E 50 WOLL7/50 L1/E 50 L1/S WIL 100 L1/E L1/S WIL 75 L1/S WIL 100 100L1/S WOL L1/E 75 L1/S 110 L1/S 50WOLL1/HD WIL 75 L1/E 50 L1/E 75L1/S L7/75 L7/50 L1/HDL1/S WIL 100 110 L1/E 50 L1/S 75 WOL 75 WOL L7/50 L1/HD WIL 100 L1/HD WIL 100
Standard
L1/HD WIL 100 L1/S 75 WOL
L1/HD WIL 75 L1/HD WIL 100
L1/HD 100
L1/E 75
L1/HD WIL 100 L1/HD WILL1/HD 50 WIL 75
L 1 / X H D W I L L1/HD 1 0 0WIL 100
L 1 / X HL1/HD D WIL W I50LL1/HD 7 5 WIL 75L1/HD WIL 50 L1/HD WIL 75
L1/HD 100
L1/HD 100 L1/HD WILL1/HD 50 WIL 75
L7/75
L1/XHD 50 L1/HD 75 L1/S WIL 100
Standard
L1/HD WIL 100 L1/HD WILL1/HD 50 WIL 75
L1/E 75 L1/S 75 WOL
50
L1/HD WIL 50 L1/E 50
L1/HD 100 L1/HD L1/HD WIL 50 WIL 75
L1/S 75 L1/E WOL75
Page 14
Page 13
L1/HD 100
LOAD
L1/HD WIL 100 L1/S 75 WOL
L1/HD WIL L1/HD 100 WIL 75
Duty
L 1/ S W O L 50
TYPE
L1/HD WIL 100
L1/HD WIL 50 L1/HD WIL 75L1/HD WIL 50 L1/HD WIL 75
Heavy
L1/HD 75 L1/XHD 50 L1/HD 75 L1/HD 100 L1/S 50 WOL
L1/S 50 50 WOL L1/S WIL 100 L1/E
L1/S 150
L1/HD 100
Page 12
L1/S WIL 75 L1/S WIL 100 L1/S 50 WOL
L1/S WOL L8/50 to read the Technical Information pages 33-35 toL8/50verify L1/E WIL50L8/50 L1/S L1/E100 WIL50 L1/S 150 150
Page 13
L1/HD WIL 50
L1/S 110
L1/S 50 WOL 50 WIL 75 WOL WIL110 100 L1/S L1/HD L1/HD WIL 100 L1/S 100 WOLL7/50 WIL 75 L1/HD WIL 100 L1/EL1/HD L1/E100 WIL50 L1/HD WILL1/HD 50 50 L1/S L1/E L7/50 L1/S 110 L7/50
L1/HD 50 L1/HD 75 L1/HD 100 L1/HD 50 L1/HD WIL 75 L1/HD 75 L1/HD 100 L1/HD WIL 50 L1/HD WIL 75 L1/HD 100 L1/HD 75 L1/HD WIL 100 L1/HD 100L1/HD WIL 50 5050L1/HD WIL 75 L1/HD WIL L1/HD 75 L1/HD 75 L1/HD WIL 100 L1/XHD 50 L1/S WIL 50 WOL WIL L1/E 50 L1/HD WIL 100 L1/SL1/HD WIL 100 L1/S WIL 75 L1/S WIL 50 L1/HD 75 L1/HD 100 L1/HD WIL 100 L1/HD WIL 75 L1/HD WIL 50
L1/HD 100
L1/S 110 L7/50
L 8/ 5 0
L1/HD L1/S WIL100 100 WILL1/HD WILWOL 75 L1/HD 50 L1/E L1/S 50 L1/S 50 WOL 50
Page 14
0 L1/HD 50 100 L1/S
LL1/HD 1 / X75H DL1/HDW100 I L 5 0L1/HD 75
L1/S 110 L7/50
100 L1/HD 75 L1/HDL1/HD 75 100 L1/HD 75 L1/HD L1/S WIL L1/S WIL 50 L1/XHD 50 75 WIL 50 L1/SL1/HD WIL 100 WIL 75 L1/S 50 L1/S WILL1/XHD 50 L1/S WIL 100 L1/S WIL 75
L1/HD 50
L1/HD 50
L1/E 50
L1/S 150
0
L1/HD WIL 50
L1/S 50 WOLL7/50 L1/E
L 7 /7 5
L8/50 L1/S 150
Page 13
L1/HD 100
L1/S 50 WOL L1/S WIL 100 L1/E 50
Before consulting tabular information, specifiers are advised
L1/HD 50
L1/HD 100
L1/S WIL 50 L1/S WIL 75L1/S WIL 100 L1/S 50 WOL L1/HD WIL 50 L1/HD WIL 75
L1/S
50-65 CAVITYL7/75 L1/S 110
L1/S 110
L1/S 50 WOL
Page 21
L1/S WIL 100 L1/HD WIL 75
L1/E 75 L7/50
70-90 CAVITY L1/E 50L1/S 75 WOL L7/50
WOL L1/HD WIL 100 L1/S 100 WOL L1/HD WIL 100 L1/S L1/HD WIL 100 WIL 75 L1/E100 WIL50 WIL 75 50 WOL L1/HDL1/S WILL1/HD L1/S 110 L1/E L1/HD 50 L7/50 L1/S 110 L1/E 50 L7/50 L1/S 110 L7/50
L 1/ S W I L 1 00
L 1/ H D W IL 75
L1/HD 75
L1/S 50 WOL L1/HD WIL 100 L1/E 50
L1/HD 100 L1/HD 75 L1/HD WIL 50 WIL L1/S 50 WOL L1/S 50 L1/S WOLWIL 100 L1/E 50
L1/S WIL 75L1/S WIL 50
0
L1/HD 100
L1/S 100 L1/S WIL 50L1/S WIL 75 L1/HD 100 L1/S WIL 75 L1/S WIL 100 L1/HD WIL 50 L1/HD WIL 50
40-55 CAVITY
L 7L1/S /5WIL 0 75 L1/S WIL 100
Standard
L1/S 50 WOL
WILWIL 75 100 L1/HDL1/S
100 L1/HDL1/HD 75 100 L1/HD L1/HD 75 L1/HD WIL 50 L1/XHD 50 L1/S WIL 75 L1/S WIL 100 L1/S WIL 75 L1/S WIL 100
L 1 / S L1/S W IWIL L L1/XHD 7 5L1/HD 50 75 50
L1/S 100
100 75 L1/HD L1/HD L1/HD WIL 50
Page 10
100 L1/HD 75 100 L1/HDL1/HD 75 L1/HD 75 L1/S WIL 75 L1/HD L1/S WIL 50 L1/XHD L1/XHD 50L1/S 100 WIL 50 50 L1/SL1/HD WIL 100 L1/S 100 L1/S 50 WIL 75 L1/S WIL L1/XHD 50 L1/S WIL 100 L1/S WIL 75 L1/S WIL 50 L1/HD 100 L1/HD L1/HD 100 L1/HD 75 L1/HD75 100 WIL 75 WIL 100 WIL 50 L1/HD L1/HD WIL 75 L1/XHD 50 L1/HD 50 L1/HD WIL 50 L1/S WILWIL 100L1/HD L1/S WIL 75 L1/HD L1/S WIL 50
L1/S 100
L1/HD 75
L1/SL1/S 50 75
L1/S 100 WIL 50 L1/XHD 50 L1/HD Page 975L1/HD
LL1/S 1L1/XHD /75H D50L1/SW100 I L 5 0 L1/S 75 L1/HD 75
Heavy
L1/S WIL 50 L1/S WIL 75L1/S WIL 100
L1/HDL1/HD 50 L1/HD 75 100
L1/XHD 50 L1/S WIL 50 L1/S 100
LOAD
L1/S 100 L1/S WIL 50L1/S WIL 75
L1/SL1/S 50 75 L1/S 100 L1/S 75L1/S 100L1/S WIL 50 L1/HD 75 L1/HD 50 L1/S L1/S WIL 50 L1/XHD 100 75 WIL L1/HD L1/HD 10050 L1/S WIL 75 L1/HD 100 L1/HD 75 50L1/S
L1/S WIL 100
WIL5075 L1/SWIL L1/HD
TYPE
L 1 / S 1 0 0L1/S 75L1/S 100L1/S WIL 50
L1/HD 50 75 L1/HD
L1/S 100
L1/S WIL 75
50 75 L1/SL1/S L1/S 100
50100 L1/SL1/HD 75L1/S
Page 9
L1/HD L1/S WIL100 50
L1/S WIL 50
L1/SL1/S 50 75
50 75 L 1 / H D 7 5 L1/SL1/S
L1/HD 50
L 1/ X H D 50
Heavy L1/S 50
L1/S 50
L1/HD 50
Page 8
Extra
Page 9
95-110 CAVITY L1/SL1/HD 100 75
SIZE
L1/S 50
L 1/ S 5 0
L1/HD 50L1/S 100 L1/S 75
70-95 CAVITY L1/S 50 L1/S 75
BLOCK
50-70 CAVITY
TIMBER FRAME CONCRETE INNER
LOAD
WIDER CAVITIES
TYPE
L1/S 50
50
L1/S 100
L1/S 75
L1/E 75
L7/75
L1/S 130 L7/75
L7/75
L1/S 130
L7/75
L8/50
L1/E WIL50
L8/50
L1/E WIL50
L8/50
L1/E WIL50 50 L8/50
L8/50
L1/S 130
L7/75 L7/75
L1/S 130
L1/S 150
60
L1/S 150
For standard duty loading conditions only L1/S 150
L1/S 150
CL1/SA150 VITY
L8/50
L1/S 150
L1/S 130
L1/S 130
LINTE LS SELE CTION CHART
L8/50
L1/S 150
L1/S 130
L1/S 130
L8/50
L1/S 150
L1/S 130
L1/S 130
70
L1/S 150
L1/S 150
SIZE
(Clear)
80
95 150 L1/S
100
105
110
130
150
100
L1/S 50
L1/S 50
L1/S 75
L1/S 75
L1/S 100
L1/S 100
L1/S 100
L1/S 110
L1/S 130
L1/S 150
115
L1/S 50
L1/S 50
L1/S 75
L1/S 75
L1/S 100
L1/S 100
L1/S 100
L1/S 110
L1/S 130
L1/S 150
125
*L1/S 50/ L1/S WIL 50 *L1/S 75/ L1/S WIL 75 L1/S WIL 50 L1/S WIL 75
L1/S 100
L1/S WIL 100 L1/S WIL 100
*L1/S 110/ *L1/S 130/ *L1/S 150/ L1/S WIL 110 L1/S WIL 130 L1/S WIL 150
130
L1/S WIL 50 L1/S WIL 50 L1/S WIL 75 L1/S WIL 75 L1/S WIL 100 L1/S WIL 100 L1/S WIL 100 L1/S WIL 110 L1/S WIL 130 L1/S WIL 150
140
L1/S WIL 50 L1/S WIL 50 L1/S WIL 75 L1/S WIL 75 L1/S WIL 100 L1/S WIL 100 L1/S WIL 100 L1/S WIL 110 L1/S WIL 130 L1/S WIL 150
150
*L1/S WIL 50 *L1/S WIL 50 *L1/S WIL 75 *L1/S WIL 75 *L1/S WIL 100 *L1/S WIL 100 *L1/S WIL 100 *L1/S WIL 110 *L1/S WIL 130 *L1/S WIL 150
190
WIL 50/200
WIL 50/200
WIL 75/200
WIL 75/200 WIL 100/200 WIL 100/200 WIL 100/200 WIL 110/200 WIL 130/200 WIL 150/200
215
WIL 50/200
WIL 50/200
WIL 75/200
WIL 75/200 WIL 100/200 WIL 100/200 WIL 100/200 WIL 110/200 WIL 130/200 WIL 150/200
Heavy Duty
Page 19
Page 19
Page 19 L1/S 100 WOL
L1/HD WIL 100
L6/75
L8/50
L1/E WIL50 L6/75
L5/75
4
L6/100
N.B.
L1/S 150 L6/75 L5/100
*Upstand to be positioned tight to inner block. Maximum overhang 25mm on either flange FOR INSULATED BONDED BLOCK ARRANGEMENTS CONTACT TECHNICAL DEPARTMENT
L6/100
5 L6/100
L5/100
L7/50 L7/50
L8/50
Cavity Wall Lintels L8/50 L8/50
S IN G LE WAL L
L9
L9L9
Page 23
L 10
L11
L11 L11
L10
L11
BOX LINTEL S
Page 24-25
BOX 1 0 0
B O X 14 0
BOX 7 5
S PE C IA L L I NT E LS ARCH LINTEL L10 L10
The L1 Profile
N ON- CAVIT Y WAL L LI NTE L S L11
L9
BOX 2 0 0
Page 27
64 & 1 00
Pages 29-32
MITRED LINTEL Page 31
Page 30
INTERNAL
RADIUS PLAN LINTEL
Page 32
L11 L11
Where lintel requirements cannot be met from the standard range, please refer to our Special Lintels Service on page 29.
STAINLES S ST E E L L INT E L S S TAI NL E SS S TE EL L IN TE LS
Page 29
U NIVE RSAL ARCHES ARCHE S
Page 28
High Performance Lintels for harsh environments
L1 type lintels have a ‘top hat’ profile which offers distinct advantages in terms of durability and structural characteristics including: The maintenance of the integrity of the wall structure and its thermal properties through uniform and continuous bricklaying the upstand of the lintel sits within the cavity;
dpc
LINTEL SO F F IT C L A DDI NG S O FF I T C LAD D IN G
Page 28
C AVIT Y T RAYS
Expanded polystyrene
CAVITY T RAYS
Easy curtain bracket fixing. No batten required
Page 36
A unique single element cavity tray system
Indented flange for plaster key
Excellent thermal efficiency as a direct result of its design which, with the addition of an expanded polystyrene infill (standard on allL1 lintels) , provides a ‘U’ value through the lintel of significantly less than 0.33 W/m2 K; Reduced maintenance costs through the elimination of cracked plaster due to the differential expansion of dissimilar materials associated with Box section lintels. Semi-pierced slots on the inner flange give an excellent key for the plaster finish.
Plaster key across cavity
6
7
CAVITY
WALL
50-70 mm
LINTELS
CAVITY
WALL
70-95 mm
LINTELS
CAVITY
CAVITY
L1/S 5 0
Manufactured Length 150mm increments
L1/S 75
Manufactured Length 150mm increments
For 50-70mm cavity wall construction. Standard duty loading condition.
Height ‘h’
79
98
110
134
150
172
172
209
209
209
For 70-95mm cavity wall construction. Standard duty loading condition.
Height ‘h’
98
89
106
130
142
168
204
204
204
Thickness ‘t’
1.6
1.8
2
2
2
2
2.5
2.9
2.9
3.2
Thickness ‘t’
1.6
1.8
2
2
2
2.5
2.9
2.9
3.2
Total UDL (kN) Load ratio (1)
12
14
19
21
21
26
27
27
26
27
Total UDL(kN) Load ratio (1)
12
14
18
21
21
27
27
26
27
Total UDL (kN) Load ratio (2)
10
12
16
17
19
22
20
20
19
22
Total UDL(kN) Load ratio (2)
10
12
14
17
19
22
20
19
22
0600 1350 1650 1950 2250 2550 2850 3150 3750 4200 1200 1500 1800 2100 2400 2700 3000 3600 4050 4800
‘h’ nominal
95
48
‘h’ nominal
100
95
L1/S 50
68
100 L1/S 75
L1/HD 50
Manufactured Length 150mm increments
0600 1350 1650 2250 2700 3150 3750 1200 1500 2100 2550 3000 3600 4200
L1/HD 75
For 50-70mm cavity wall construction. L1/S 50 Heavy duty loading condition.
Height ‘h’
105
121
171
209
209
209
209
Thickness ‘t’
2.9
2.9
2.9
3.2
3.2
3.2
3.2
For 70-95mm cavity wall construction. L1/Scondition. 75 Heavy duty loading
Total UDL (kN) Load ratio (1)
30
30
40
40
40
35
Total UDL (kN) Load ratio (2)
22
22
35
35
35
32
L1/HD 50
Manufactured Length 150mm increments
0600 1350 1650 2250 2700 3150 3750 1200 1500 2100 2550 3000 3600 4200
Height ‘h’
103
117
167
205
205
205
205
Thickness ‘t’
2.9
2.9
2.9
3.2
3.2
3.2
3.2
33
Total UDL(kN) Load ratio (1)
30
30
40
40
40
35
33
28
Total UDL(kN) Load ratio (2)
22
22
35
35
35
32
28
L1/HD 75
‘h’ nominal
‘h’ nominal
95
48
L1/S 50
95
100
L1/HD 50
68 L1/S 10075
L1/HD 75
L1/HD 75
L1/XHD 50
L1/XHD 50
Manufactured Length 150mm increments
0600 1650 1500 1800
1950 2100
L1/XHD 75
Manufactured Length 150mm increments
0600 1650 1950 1500 1800 2100
For 50-70mm cavity wall construction. L1/HD 50 Extra heavy duty loading condition.
Height ‘h’
171
171
209
Height ‘h’
167
167
205
Thickness ‘t’
3.2
3.2
3.2
For 70-95mm cavity wall construction. L1/HD 75 Extra heavy duty loading condition.
Thickness ‘t’
3.2
3.2
3.2
Total UDL (kN) Load ratio (1)
50
50
55
Total UDL(kN) Load ratio (1)
50
50
55
Total UDL (kN) Load ratio (2)
45
45
45
Total UDL(kN) Load ratio (2)
45
45
45
L1/XHD 50
L1/HD 75
‘h’ nominal
‘h’ nominal
95
8
0600 1350 1650 1950 2250 2550 3150 3750 4200 1200 1500 1800 2100 2400 3000 3600 4050 4800
48
100 L1/XHD 50
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
95
68
100 L1/HD 75
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
9
CAVITY
WALL
95-110 mm
LINTELS
CAVITY
WALL
110-150 mm
LINTELS
CAVITY
CAVITY
L1/S 1 00
Manufactured Length 150mm increments
L1/S 110
Manufactured Length 150mm increments
For 95-110mm cavity wall construction. Standard duty loading condition.
Height ‘h’
88
88
107
125
150
162
171
200
200
200
For 110-125mm cavity wall construction. Standard duty loading condition.
Height ‘h’
95
121
145
195
195
195
Thickness ‘t’
1.6
1.8
2
2
2
2.5
2.5
2.9
2.9
3.2
Thickness ‘t’
2
2
2.5
2.9
3.2
3.2
Total UDL(kN) Load ratio (1)
12
16
19
21
23
27
27
27
26
27
Total UDL(kN) Load ratio (1)
16
22
24
27
26
25
Total UDL(kN) Load ratio (2)
10
13
16
17
18
22
20
20
19
22
Total UDL(kN) Load ratio (2)
13
18
18
22
19
20
0600 1350 1650 1950 2250 2550 2850 3150 3750 4200 1200 1500 1800 2100 2400 2700 3000 3600 4050 4800
‘h’ nominal 95
88
0600 1650 1950 2250 3150 4200 1500 1800 2100 3000 4050 4800
‘h’ nominal
100
95
108
100
L1/S 100
L1/HD 100
Manufactured Length 150mm increments
For 95-110mm cavity wall construction. Heavy duty loading L1/Scondition. 100
Height ‘h’
L1/HD 100
1350 1650 2250 2700 3150 3750 1500 2100 2550 3000 3600 4200
L1/S 130
Manufactured Length 150mm increments
0600 1650 1950 2550 3150 4200 1500 1800 2100 3000 4050 4800
110
135
163
203
203
203
203
Height ‘h’
103
128
190
190
190
190
Thickness ‘t’
2.9
2.9
2.9
3.2
3.2
3.2
3.2
For 130-145mm cavity wall construction. Standard duty loading condition.
Thickness ‘t’
2
2
2.5
2.9
3.2
3.2
Total UDL(kN) Load ratio (1)
30
30
40
40
40
35
33
Total UDL(kN) Load ratio (1)
16
22
24
27
26
25
Total UDL(kN) Load ratio (2)
22
22
35
35
35
32
28
Total UDL(kN) Load ratio (2)
13
18
18
22
19
20
0600 1200
‘h’
‘h’ nominal
95
nominal
100 88 L1/S100
95
128
100
L1/HD 100
L1/HD 100
L1/XHD 10 0
Manufactured Length 150mm increments
0600 1650 1950 1500 1800 2100
L1/S 150
Manufactured Length 150mm increments
0600 1650 1950 2250 3150 4200 1500 1800 2100 3000 4050 4800
For 95-110mm cavity wall construction. L1/HD 100 Extra heavy duty loading condition.
Height ‘h’
163
163
203
Height ‘h’
100
125
180
180
180
180
Thickness ‘t’
3.2
3.2
3.2
For 150-165mm cavity wall construction. Standard duty loading condition.
Thickness ‘t’
2
2
2.5
2.9
3.2
3.2
Total UDL(kN) Load ratio (1)
50
50
55
Total UDL(kN) Load ratio (1)
16
22
24
27
26
25
Total UDL(kN) Load ratio (2)
45
45
45
Total UDL(kN) Load ratio (2)
13
18
18
22
19
20
L1/HD 100
‘h’
‘h’ nominal
95
10
88
100 L1/HD 100
nominal
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
95
148
100
All above Lintels have continuous bottom plates. Heavy duty and Wider Inner Leaf variants available.
Load Ratio - see Structural Performance on page 33.
11
50-70 mm
WIDE INNER LEAF
70-95 mm
WIDE INNER LEAF
CAVITY
L1/S WI L 50
Manufactured Length 150mm increments
For 50-70mm cavity wall construction. Standard duty loading condition.
Height ‘h’
96
110
136
162
172
196
196
Thickness ‘t’
2
2
2
2
2.5
3.2
3.2
Total UDL(kN) Load ratio (1)
12
15
20
24
28
30
27
Total UDL(kN) Load ratio (2)
10
13
18
20
21
26
25
0600 1650 1500 1800
1950 2250 2550 3150 3750 2100 2400 3000 3600 4200
CAVITY
L1/S WI L 7 5 For 70-95mm cavity wall with wide inner block/brick construction. Standard duty loading condition.
48
95
125
68
L1/HD WIL 5 0
Manufactured Length 150mm increments
For 50-70mm cavity wall construction. Heavy duty loading L1/Scondition. WIL 50
Height ‘h’
95
109
161
161
200
Thickness ‘t’
2.9
2.9
2.9
2.9
3.2
Total UDL(kN) Load ratio (1)
20
25
35
30
36
Total UDL(kN) Load ratio (2)
17
22
27
25
32
L1/HD WIL 50
0600 1350 1200 1500
L1/HD WIL 75
1650 1950 2250 1800 2100 2700
For 70-95mm cavity wall with wide inner block/brick construction. L1/S WIL 75 Heavy duty loading condition. L1/HD WIL 75
101
90
110
134
158
167
192
192
Thickness ‘t’
2
2
2
2
2
2.5
3.2
3.2
Total UDL(kN) Load ratio (1)
12
13
20
19
24
27
30
27
Total UDL(kN) Load ratio (2)
10
11
17
17
20
21
26
25
Manufactured Length 150mm increments
0600 1350 1950 2250 1200 1800 2100 2700
Height ‘h’
130
155
192
192
Thickness ‘t’
2.9
2.9
2.9
3.2
Total UDL(kN) Load ratio (1)
20
25
30
36
Total UDL(kN) Load ratio (2)
17
22
25
32
‘h’ nominal
L1/S 125WIL 50
95
68
L1/S WIL 75
125
L1/HD WIL 75
L1/HD WIL 50
L1/HD WIL 50
L1/HD WIL 75
L1/XHD WI L 50
Manufactured Length 150mm increments
0600 1650 1500 1800
1950 2100
L1/XHD WIL 75
Manufactured Length 150mm increments
0600 1650 1950 1500 1800 2100
For 50-70mm cavity wall construction. L1/HD WIL 50 Extra heavy duty loading condition.
Height ‘h’
161
196
196
Height ‘h’
157
192
192
Thickness ‘t’
3.2
3.2
3.2
For 70-95mm cavity wall with wide inner L1/HD block/brick WIL 75 construction. Extra heavy duty loading condition.
Thickness ‘t’
3.2
3.2
3.2
Total UDL(kN) Load ratio (1)
45
45
50
Total UDL(kN) Load ratio (1)
45
45
50
Total UDL(kN) Load ratio (2)
40
40
40
Total UDL(kN) Load ratio (2)
40
40
40
L1/HD WIL 50
L1/HD WIL 75
‘h’ nominal
‘h’ nominal
95
12
Height ‘h’
125
‘h’ nominal
48
1950 2250 2550 3150 3750 1800 2100 2400 3000 3600 4200
L1/S WIL 75
L1/S WIL 50
95
0600 1500 1350 1650
‘h’ nominal
‘h’ nominal 95
Manufactured Length 150mm increments
48
125 L1/HD WIL 50
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
95
68
125 L1/HD WIL 75
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
13
95-110 mm
WIDE INNER LEAF
50-110 mm
WIDE OUTER LEAF
CAVITY
L1/S WI L 100
Manufactured Length 150mm increments
For 95-110mm cavity wall with wide inner block/brick construction. Standard duty loading condition.
Height ‘h’
92
Thickness ‘t’
CAVITY
1950 2550 3150 3750 2400 3000 3600 4200
L1/S WOL 50
Manufactured Length 150mm increments
107
150
177
188
188
Height ‘h’
93
110
162
200
200
200
2
2
2
2.5
3.2
3.2
For 50-70mm cavity wall construction with wide outer masonry. Standard duty loading.
Thickness ‘t’
2.5
2.5
2.5
2.9
3.2
3.2
Total UDL(kN) Load ratio (1)
13
17
23
24
30
27
Total UDL(kN) Load ratio (1)
14
15
23
30
32
30
Total UDL(kN) Load ratio (2)
11
14
18
18
26
25
Total UDL(kN) Load ratio (2)
11
13
18
22
30
26
0600 1350 1200 1800
150 max
‘h’ nominal
‘h’ nominal
95
88
125
125
L1/HD WIL 1 00
Manufactured Length 150mm increments
0600 1500 1350 1800
1950 2250 2100 2700
For 95-110mm cavity wall with wide inner block/brick construction. Heavy duty loading condition.
Height ‘h’
113
150
188
188
Thickness ‘t’
2.9
2.9
2.9
3.2
Total UDL(kN) Load ratio (1)
20
25
30
36
Total UDL(kN) Load ratio (2)
17
22
25
32
100
48
L1/S 50 WOL
L1/S WOL 75
Manufactured Length 150mm increments
For 70-95mm cavity wall L1/S 50 WOL construction with wide outer masonry. Standard duty loading. L1/S 75 WOL
‘h’ nominal
0600 1500 1800 2250 2850 3150 1350 1650 2100 2700 3000 3600
‘h’ L1/S 50 WOL
150 max
0600 1500 1800 2250 2850 3150 1350 1650 2100 2700 3000 3600
Height ‘h’
93
110
162
200
200
200
Thickness ‘t’
2.5
2.5
2.5
2.9
3.2
3.2
Total UDL(kN) Load ratio (1)
14
15
23
30
32
30
Total UDL(kN) Load ratio (2)
11
13
18
22
30
26
nominal
95
88
125
125
68
100 L1/S 75 WOL
L1/XHD WIL 100 For 95-110mm cavity wall with wide inner block/brick construction. Extra heavy duty loading condition.
Manufactured Length 150mm increments
0600 1650 1500 1800
1950 2100
Height ‘h’
165
188
188
Thickness ‘t’
3.2
3.2
3.2
Total UDL(kN) Load ratio (1)
45
45
50
Total UDL(kN) Load ratio (2)
40
40
40
L 1 / S W OL1/S L 100 1 0WOL 0 For 95-110mm cavity wall L1/Souter 75 WOL construction with wide masonry. Standard duty loading. L1/S 100 WOL
14
88
125
0600 1500 1800 2250 2850 3150 1350 1650 2100 2700 3000 3600
Height ‘h’
93
110
162
200
200
200
Thickness ‘t’
2.5
2.5
2.5
2.9
3.2
3.2
Total UDL(kN) Load ratio (1)
14
15
23
30
32
30
Total UDL(kN) Load ratio (2)
11
13
18
22
30
26
150 max
‘h’ nominal
95
Manufactured Length 150mm increments
‘h’ nominal
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
125
88
100 L1/S 100 WOL
All above Lintels have continuous bottom plates. Heavy duty and Wider Inner Leaf variants available.
Load Ratio - see Structural Performance on page 33.
15
50-100 mm
L1/E-STANDARD AND INNER LEAF
CAVITY
L1/E Eaves Lintels
Note: Maximum block dimensions 125mm (80mm cavity)
L1/E 50
Manufactured Length 150mm increments
For 50-80mm (max) cavity wall construction. For use at eaves level. Composite beam with blockwork
Height ‘h’
95
134
150
150
Thickness ‘t’
2
2
2
2.5
Total UDL(kN)
18
20
22
25
0600 1650 2250 2550 1500 2100 2400 2700
‘h’ nominal
45 48
100 L1/E 50 Note: Maximum block dimensions 125mm (100mm cavity)
L1/E 75
Manufactured Length 150mm increments
For 70-100mm (max) cavity wall construction. For use at eaves level. Composite beam with blockwork
Height ‘h’
95
134
150
150
Thickness ‘t’
2
2
2
2.5
Total UDL(kN)
18
20
22
25
L1/E 75
0600 1650 2250 2550 1500 2100 2400 2700
‘h’ nominal
L1/E lintels are designed to provide support over
45 68
100 L1/E 50
openings at eaves level. To achieve the loading figures indicated on the opposite page, the lintel must be built in with the
Note: Maximum block dimensions 150mm (80mm cavity)
blockwork as shown, and a continuous wall plate must be provided over the opening and reveals. Expanded polystyrene
The loading figures are achieved by using composite action of the inner leaf blockwork.
Easy curtain bracket fixing. No batten required Indented plaster key
Providing the maximum cavity width for the appropriate lintel is maintained the outer flange will have a brickwork bearing of 13mm.
L1/E WI L 5 0
Manufactured Length 150mm increments
For 50-80mm (max) cavity wall construction. For use at eaves level. Composite beam with wide inner leaf blockwork
Height ‘h’
91
136
136
150
Thickness ‘t’
2
2
2.5
2.5
Total UDL(kN)
18
20
25
20
L1/E WIL50
L1/E 75
The lintels must be ‘built in’ with the blockwork positioned against the upstand of the lintel
Plaster key across cavity
together with a continuous wall plate as shown.
0600 1650 2250 2550 1500 2100 2400 2700
‘h’ nominal
45 48
16
125 L1/E 50
All above Lintels have continuous bottom plates.
Load Ratio - see Structural Performance on page 33.
17
50-110 mm
Heavy Duty Lintels
CAVITY
50-110 mm
Extra Heavy Duty Lintels
Note: Maximum block dimensions 125mm (50mm cavity)
CAVITY
Note: Maximum block dimensions 125mm positioned flush with inner face of Universal Beam (50mm cavity)
L5/50
Manufactured Length 150mm increments
0600 1650 2250 3150 4200 1500 2100 3000 4050 4800
L6/50
Manufactured Length 150mm increments
0600 5200 5400 5800 6200 6600 4800
For 50-70mm cavity wall construction. Heavy duty loading condition.
Height ‘h’
229
229
229
229
229
End bearing
200
200
200
200
200
200
Thickness ‘t’
2.9
2.9
2.9
3.2
3.2
For large span 50-70mm cavity wall construction. Extra heavy duty loading condition.
Total allowable UDL (kN)
86
75
70
65
60
55
Total UDL(kN) Load ratio 19:1
70
60
50
45
40
‘h’ nominal
95
207
100
48
Manufactured from a 203 x 133 x 30kg/m Universal Beam, with external galvanised outer flange and galvanised base plate.
L5 L5/50
245 Note: Maximum block dimensions 125mm (70mm cavity)
L5/75
Manufactured Length 150mm increments
0600 1650 2250 3150 4200 1500 2100 3000 4050 4800
For 70-95mm cavity wall construction. L5 L5/50 Heavy duty loading condition.
Height ‘h’
229
229
229
229
229
Thickness ‘t’
2.9
2.9
2.9
3.2
3.2
Total UDL(kN) Load ratio 19:1
70
60
50
45
40
L5/75
Note: Maximum block dimensions 125mm positioned flush with inner face of Universal Beam (70mm cavity)
L6/75
L6/75
For large span 70-90mm cavity wall construction. Extra heavy duty loading condition.
Manufactured Length 150mm increments
0600 5200 5400 5800 6200 6600 4800
End bearing
200
200
200
200
200
200
Total allowable UDL (kN)
86
75
70
65
60
55
‘h’ nominal 207
L5 L5/50
95
68
100 Manufactured from a 203 x 133 x 30kg/m Universal Beam, with external galvanised outer flange and galvanised base plate.
L5/75
265
Note: Maximum block dimensions 125mm (95mm cavity)
L5/100
L5/100
For 95-110mm cavity wall construction. Heavy duty loadingL5/75 condition. L5/100
Note: Maximum block dimensions 125mm positioned flush with inner face of Universal Beam (95mm cavity)
L6/75
Manufactured Length 150mm increments
0600 1650 2250 3150 4200 1500 2100 3000 4050 4800
L6/100
Height ‘h’
229
229
229
229
229
Thickness ‘t’
2.9
2.9
2.9
3.2
3.2
For large span 95-110mm cavity wall construction. Extra heavy duty loading condition.
Total UDL(kN) Load ratio 19:1
70
60
50
45
40
‘h’ nominal
95
18
88
100 L5/100
Manufactured Length 150mm increments
0600 5200 5400 5800 6200 6600 4800
End bearing
200
200
200
200
200
200
Total allowable UDL (kN)
86
75
70
65
60
55
207
All above Lintels have continuous bottom plates. Heavy duty variants available.
Load Ratio - see Structural Performance on page 33.
Manufactured from a 203 x 133 x 30kg/m Universal Beam, with external galvanised outer flange and galvanised base plate.
285
19 L6/100
45-55 mm
L7-TIMBER FRAME
CAVITY
Timber Frame Lintels
L7/50
Manufactured Length 150mm increments
0600 1350 1950 2550 3750 1200 1800 2400 3600 4800
For 45-55mm cavity timber frame construction. Wider or narrower cavity lintels are available but not stocked. Information on request.
Height ‘h’
110
110
135
185
250
Thickness ‘t’
2.0
2.5
2.5
2.8
3.0
4
5
5
9
12
Total Allowable UDL (kN)
25 23 ‘h’ nominal
95
Heavy duty and wider cavity variants available.
40 L7/50
L7-TIMBER
70-85 mm
FRAME
CAVITY
L7/75
Manufactured Length 150mm increments
0600 1950 2550 3750 1800 2400 3600 4800
For 70-85mm cavity timber frame construction. Wider or narrower cavity lintels are available but not stocked. Information on request. L8/50
Height ‘h’
165
165
240
315
Thickness ‘t’
2.0
2.5
3.0
3.0
9
12
12
12
Total Allowable UDL (kN)
25 40 Wider cavity variants available.
‘h’ nominal
Designed for use in timber frame construction, the L7 lintel provides support to the outer leaf to brickwork over openings. dpc Retaining clip
38mm timber block (not supplied)
95 L7/50
To achieve the loading figures shown, the L7 lintel must be secured with restraining clips and a block /batten (not supplied) must be used to prevent lateral deflection (twist) during the building stage. A single block/batten 300mm long at mid span will be sufficient. Restraining clips should be fixed with 3.3 x 50mm galvanised nails at no more than 500mm centres each side of mid span. Clips should be positioned with their vertical centres at the top of the lintel to allow for lintel movement and shrinkage of timber frame.
68
50-65 mm
L 8 - C O N C L9 R E T E I N N E R L I N T EL11 L
CAVITY
Note; When specifying check height dimensions
L8/50
L8/50
For 50-65mm cavity wall construction. For use with concrete L7/50 lintels. Wider or narrower cavity lintels are available but not stocked. Information on request. L10
Manufactured Length 150mm increments
0600 2250 2550 3150 2100 2400 3000 4800
Height ‘h’
150
225
225
225
Thickness ‘t’
2.5
2.5
2.9
3.2
7
8
10
12
L11
Total Allowable UDL (kN)
‘h’ nominal Wider cavity variants available.
20
95
48 40 L8/50
21
L7/50
SINGLE WALL LINTELS
Single Wall Lintels
Note: This Lintel must be propped during construction.
L7/50
L9
Manufactured Length 150mm increments
For use with solid brick or block wall construction.L8/50 Light duty loading condition.
0600 1350 1800 2250 1200 1650 2100 2700
Height ‘h’
55
86
86
113
Thickness ‘t’
2.5
2.5
2.9
3.2
6
8
8
10
Total Allowable UDL (kN)
‘h’ nominal
200 L9
L8/50
Heavy duty and wider masonry variants available.
L11 Note: This Lintel must be propped during construction.
LL7/50 10
Manufactured Length 150mm increments
For use with single 102mm L9 brickwork wall construction. Light duty loading condition.
Height ‘h’
Thickness ‘t’
L10
Face brickwork
L7/50
IG Single Wall Lintels are for the support of loads from half-brick to full brick widths in solid brick or block wall construction.
Total Allowable UDL (kN) L11
L8/50 95
Door lining Door stop
110
210
210
3.0
3.0
2.8
3.0
4
8
10
6
Heavy duty and wider masonry variants available.
L10
L11 Note: This Lintel must be propped during construction.
The L9 Lintel allows the face of brickwork to show on both sides of an opening in a full brick-wide wall.
L11
Meter Box Lintel, L10 and L11 lintels allow the face of the brickwork to show on one side of an opening in half-brick wide constructions. Meter Box Lintel lengths from 750-1350mm in increments of 150mm.
Manufactured Length 150mm increments
Height ‘h’ For use with single leaf face brick L9 or block wall. L11
L8/50
Door
Single skin lintels should always be propped. NHBC guidelines propose no greater than a 1m span for props during construction.
22
60
‘h’ nominal
L10 lintel
Architrave
L11
0600 1350 1950 2850 1200 1800 2700 3000
0600 1950 2550 2850 1800 2400 2700 3600
150
225
225
225
Thickness ‘t’
2.5
2.5
2.9
3.2
Total Allowable UDL (kN)
16
20
12
12
225 150
L9
L10
Heavy duty and wider masonry variants available.
95
95
L11
L11
To achieve loading figures indicated, lintel must be built-in with brickwork/blockwork as shown. In addition, it must be suitably restrained during construction. Heavier duty variants available.
23
75-215 mm
BOX LINTELS - STANDARD
BLOCKWORK
Box Lintels B OX 100
Manufactured Length 150mm increments
For internal openings, eaves or 100 block and tile hanging.
Height ‘h’
75
150
150
150
215
215
215
Thickness ‘t’
2
1.6
2
2
2.5
2.5
2.5
Total allowable UDL (kN)
18
18
25
20
30
25
20
0600 1650 1950 2550 2850 3750 4350 1500 1800 2400 2700 3600 4200 4800
95 95 ‘h’ nominal 75
Perforated steel for plaster key
BOX 140
Manufactured Length 150mm increments
0600 1650 2250 2550 2850 3750 4350 1500 2100 2400 2700 3600 4200 4800
For internal openings, eaves or 140/150 block and tile hanging.
Height ‘h’
150
150
150
150
215
215
215
Thickness ‘t’
1.6
2
2
2
2.5
2.5
2.5
Total allowable UDL (kN)
15
30
25
20
35
30
25
145
‘h’ nominal
Perforated steel for plaster key
B OX 75 For internal openings, 75 blockwork or 100 blockwork.
Manufactured Length 150mm increments
Height ‘h’ Height ‘h’
75mm wide 100mm wide
Thickness ‘t’
0600 1650 1800
100 75
1.6
100 75
Box lintels are designed for use over internal or external openings, or when tile hanging is required with solid brick or block wall construction, or at eaves level.
2.0
BOX 200
Manufactured Length 150mm increments
0600 1950 2550 2850 3750 4350 1800 2400 2700 3600 4200 4800
For internal openings, eaves or 215 block and tile hanging.
Height ‘h’
150
150
150
215
215
215
Thickness ‘t’
1.6
2
2
2.5
2.5
2.5
Total allowable UDL (kN)
18
25
20
30
25
20
95 75
Total allowable UDL (kN)
15
10
Perforated steel for plaster key
‘h’ nominal Care should be taken to avoid shock loading when used with concrete floor or other heavy units. Insulation available at extra cost.
24
200 Perforated steel for plaster key
NOTE: The Flange of the Box 200 (or HD Box 200) is designed to support a nominal masonry load only, up to a maximum of 3kN/m run.
25
100-215 mm
BOX LINTELS - HEAVY DUTY
BLOCKWORK
Internal Lintels HD B OX 100
Manufactured Length 150mm increments
0600 1350 1950 1200 1800 2700
For internal openings, eaves or 100 block and tile hanging.
Height ‘h’
150
150
215
Thickness ‘t’
2.5
2.5
2.5
Total allowable UDL (kN)
50
45
40
64 & 100
‘h’ nominal
100 95
Rendering
100mm lintel Architrave
Perforated steel for plaster key
Plaster facing 28
Door liner
HD B OX 140
Manufactured Length 150mm increments
0600 1350 1950 1200 1800 2700
For internal openings, eaves or 140/150 block and tile hanging.
Height ‘h’
150
150
215
Thickness ‘t’
2.5
2.5
2.5
Total allowable UDL (kN)
50
45
40
Door
Door stop stop
‘h’ nominal
145
Perforated steel for plaster key
H D BOX 200
Manufactured Length 150mm increments
0600 1350 1950 1200 1800 2700
For internal openings, eaves or 215 block and tile hanging.
Height ‘h’
150
50
2.5
45
2.5
40
INT 100 (G790)
Total allowable UDL (kN)
2.5
‘h’ nominal
200
Overall Length of IG Lintel
Maximum Width of span of IG Lintel opening unit
Safe Safe distributed distributed loading with loading with 152mm coursing 229mm coursing of 100mm thick of 75/100mm thick walling above walling above lintel unit lintel unit
215
INT 64 (G780)
Thickness ‘t’
150
CAD CODES
I NT ER NA L 64 & 100
900
700
64
-
5
1050
850
64
-
5
1100
900
64
-
5
1200
1000
64
-
5
900
700
100
5
7
1050
850
100
5
7
1100
900
100
5
7
1200
1000
100
5
7
Designed to provide a quick and safe method of spanning small openings (up to 1000mm) in internal walls, IG internal lintels are both economical and easy to store, carry and use. When a minimum height of 152mm of brick/blockwork with well-filled joints of cement mortar is built over the lintel, the construction will be load-bearing for normal domestic building purposes after curing. The loading capacity of the lintel can be increased by increasing the height of the walling built across it.
In some circumstances these lintels may have an expanded metal lathing attached and may differ from the diagram shown.
Care should be taken to avoid shock loading when used with concrete floor or other heavy units. Perforated steel for plaster key
26
Insulation available at extra cost
NOTE: The Flange of the Box 200 (or HD Box 200) is designed to support a nominal masonry load only, up to a maximum of 3kN/m run.
27
Lintel Soffit Cladding
Stainless Steel Lintels High Performance for harsh environments
Manufactured from rigid PVC to match UPVC window frames, the IG lintel soffit cladding is designed to clip over the front flange of the external wall lintel to provide an aesthetically pleasing appearance to the exposed outer flange.
• IG standard lintels are available in stainless steel.
Supplied in white (type SCW) and brown (type SCB), soffit cladding is available in lengths to meet all standard openings, for example a 1500 mm length is available to fit a structural opening width of 1200 mm. The cladding simply clips into place - no special tools are required.
• Outstanding durability through austenitic chromium nickel steel to BS EN 10088-2 1.4301 (304S15).
Note: When soffit cladding is used, external wall lintels must be installed with a flexible damp proof course (DPC) which must project beyond the front face of the cladding.
• Suitable for use in coastal and industrial environments. • All IG galvanised steel loading tables apply.
109mm
Universal Arch
Special Lintel Enquiry Fax Back Please complete and fax back the form overleaf...
When low rise arches are required in brickwork above openings, the IG Universal Arch provides the ideal former for the bricklayer. Vacuum-formed from white pigmented, external weathering quality, impact resistant polystyrene. Suitable for use in cavity walls and with timber frame construction, the unit is designed to sit on any steel lintel with an outer flange of 90mm to 95mm. The design provides an arch rise of 75mm for arch spans from 475mm to 1785mm, and a rise of 150mm for arch spans from 1916mm to 2725mm.
28
Opening Sizes
Nominal Arch Span
Arch Rise
IG Ref.
CAD Code
450-500 600-650 660-710 900-950 1000-1050 1060-1110 1200-1250 1300-1350 1460-1510 1600-1650 1675-1725 1760-1810 1890-1940 2010-2060 2090-2140 2250-2300 2300-2350 2400-2450 2505-2555 2700-2750
475 625 685 925 1025 1085 1225 1325 1485 1625 1700 1785 1916 2035 2115 2275 2325 2425 2530 2725
75 75 75 75 75 75 75 75 75 75 75 75 150 150 150 150 150 150 150 150
IGAR 475 IGAR 625 IGAR 685 IGAR 925 IGAR 1025 IGAR 1085 IGAR 1225 IGAR 1325 IGAR 1485 IGAR 1625 IGAR 1700 IGAR 1785 IGAR 1916 IGAR 2035 IGAR 2115 IGAR 2275 IGAR 2325 IGAR 2425 IGAR 2530 IGAR 2725
IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 75 IGAR 150 IGAR 150 IGAR 150 IGAR 150 IGAR 150 IGAR 150 IGAR 150 IGAR 150
IG’s comprehensive range of standard lintels covers all applications in conventional building constructions. When a building requires more unconventional support solutions, IG has the expertise to design and manufacture special lintels that suit all shapes and sizes. These special lintels some of which feature below - can include radius, natural arch, gothic arch, corner, apex, cant brick, ‘I’ beam, 200mm-wide inner leaf, feature plate and wider cavity.
IG’s Special Lintel Service is the product of a wide experience in successfully meeting the needs of architects of both domestic and commercial buildings. It embraces every aspect of lintel design and supply, from calculation of shape, size and loading to coordination with construction scheduling and consideration of budgetary requirement. IG’s ultimate aim is to provide the most cost-effective design solution to special lintel problems. In order to best utilise this free service, please ensure that all relevant details are provided i.e. wall construction (outer leaf, cavity, inner leaf), clear spans, arch rise, radius and any other factor which may affect the special lintel design and costing.
When loading figures are not available, then please provide a full set of drawings including: (a) plans (b) elevations (c) sections (d) wall construction (e) floor construction and direction This information will enable our design engineers to calculate the relevant loadings. Information can be sent directly to the Technical Department by email: info@igltd.co.uk or by fax back on 01633 486495.
29
FAX BACK
SPECIAL ARCH LINTELS
FAX BACK
SPECIAL MITRED LINTELS
SPECIAL MITRED LINTEL ENQUIRY FORM
SPECIAL ARCH LINTEL ENQUIRY FORM Please complete all details and submit to Technical on Fax: 01633 486495. If you require further information please Tel: 01633 486461.
Please complete all details and submit to Technical on Fax: 01633 486495. If you require further information please Tel: 01633 486461.
From:
From:
Name
Name Company
Company Tel:
Fax:
Tel:
Fax:
Job reference
Job reference
R A D I U S A RC H L I N T E L
R
AP E X LI N TE L
R
(clear span) A C
ELEVATION
Lintel Dimensions
x째
C
(clear span) A
Wall Construction
ELEVATION
C
Plaster Key Requirements (please tick) Lintel Dimensions
C
Wall Construction
Plaster Key Requirements (please tick)
Clear span
A
mm
Outer leaf
mm
Inside only
Rise
R
mm
Cavity width
mm
Both sides
Clear span
A
mm
Outer leaf
mm
Inside only
End bearing
C
mm
Inner leaf
mm
None
Rise
R
mm
Cavity width
mm
Both sides
End bearing
C
mm
Inner leaf
mm
None
N AT U R A L A R C H L I N T E L
R (clear span) A C
C
ELEVATION
Lintel Dimensions
A
BRICK REVEAL
Plaster Key Requirements (please tick)
Wall Construction
Clear span
A
mm
Outer leaf
mm
Inside only
Rise
R
mm
Cavity width
mm
Both sides
End bearing
C
mm
Inner leaf
mm
None
C O R N E R L IN T E L
BRICK REVEAL
B
C
Dimensions Required
PA RA B O L I C A RC H L I N T E L
R (clear span) A ELEVATION
C
Lintel Dimensions
C
Wall Construction
Clear span
A
mm
Outer leaf
Rise
R
mm
End bearing
C
mm
Important Notes: Do not allow for bearing, this will be added at design stage.
Wall Construction
Plaster Key Requirements (please tick)
A-B =
mm
Outer leaf
mm
Inside only
B-C =
mm
Cavity width
mm
Both sides
A-C =
mm
Inner leaf
mm
None
Plaster Key Requirements (please tick) mm
Inside only
Cavity width
mm
Both sides
Inner leaf
mm
None
Important Notes: Do not allow for bearing, this will be added at design stage.
A
BRICK REVEAL
BRICK REVEAL
D
B AY L I N T E L R
G O T H I C A R C H L IN T E L
C
B (clear span) A ELEVATION
C
Lintel Dimensions
Dimensions Required
C
Wall Construction
Plaster Key Requirements (please tick)
Clear span
A
mm
Outer leaf
mm
Inside only
Rise
R
mm
Cavity width
mm
Both sides
End bearing
C
mm
Inner leaf
mm
None
Wall Construction
Plaster Key Requirements (please tick)
A-B =
mm
Outer leaf
mm
Inside only
B-C =
mm
Cavity width
mm
Both sides
C-D =
mm
Inner leaf
mm
None
Special Lintels continued over page
Enquiries for Special Lintels should be faxed to: 01633 486495 30
Enquiries for Special Lintels should be faxed to: 01633 486495 31
SPECIAL PLAN
FAX BACK
RADIUS LINTELS
TECHNICAL INFORMATION
SPECIAL PLAN RADIUS LINTEL ENQUIRY FORM Please complete all details and submit to Technical on Fax: 01633 486495. If you require further information please Tel: 01633 486461.
From:
Name the humidity and
STRUCTURAL PERFORMANCE
Company
condensation conditions normally experienced in habitable
Tel:
Fax:
Job reference
The loading tables in this brochure are the result of testing at the group’s premises under the supervision and direction of the British Board of Agrèment.
A
Important Notes: Do not allow for bearing, this will be added at design stage.
All
tests
were
carried
out
Lintels conform to the requirements of BS EN 845–2:2003 for corrosion protection, workmanship and materials.
in
accordance
with
BS 5977 Part 2 1983 and BS EN 846–9:2000 and relate to
P L AN R A DI U S LI NT E L
buildings.
the strength and torsional stiffness of lintels to sustain total
IG lintels are rated by the Housing Association Property Mutual as satisfying the ‘35 years to first maintenance’ durability rating, laid down in the ‘HAPM Component Life Manual’.
uniformly distributed loads. R
Galvanised lintels - lintels are fabricated from galvanised The loading tables shown for the L1 (where noted), L1/E, L5 Lintel Dimensions
Wall Construction
Plaster Key Requirements (please tick)
and L11 lintels are the results of testing in accordance with
Clear span
A
mm
Outer leaf
mm
Inside only
BS 5977 Part 2 1983 and BS EN 846–9:2000, taking into
Radius
R
mm
Cavity width
mm
Both sides
account composite assistance from the surrounding
Inner leaf
mm
None
For more information on other special lintels please complete details above, tick boxes below and Faxback or contact the Technical Department Hotline on 01633 486461.
CORNER POST
CANT BRICK LINTEL
I BEAMS
VENETIAN ARCH LINTEL
steel to BS EN 10142 1991 Specification for continually hot dip zinc coated low carbon steel sheet and strip for cold forming: Technical advisory conditions, grade Fe P01 G, with a coating type Z600 giving a minimum coating weight
masonry, this masonry should be of good quality (in
(triple spot test) of 600g/m2; including both sides but with
accordance with BS 5628).
a minimum yield stress of 250 N/mm2.
A lintel should not exceed a maximum vertical or horizontal
Stainless steel - All IG lintels can be manufactured with
deflection of 1/325 x the effective span, when subject to the
stainless steel.
safe working load. Stainless steel lintels and expanded metal lathing are Note:
formed from Austenitic Chromium Nickel Steel to
Load ratio 1 - applies to loads with an inner to outer leaf ratio
BS EN 10088-2 1.4301 (304S15) and require no additional
of between 1 :1 and 3 :1. This ratio is normally applicable to
corrosion treatment. Higher grades of stainless steel can be
lintels that support:
supplied on request - BS EN 10088-2 1.4401 (316S31).
a. masonry
INSTALLATION
b. masonry and timber floors For the lintels to perform to the quoted loading figures and to Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1. This ratio is normally applicable
meet the durability expectations included in this brochure, the following information MUST be adhered to:
to lintels supporting:
TIMBER ARCH LINTEL
ISLAMIC ARCH LINTEL
a. constructions with concrete floors b. eaves applications
1. Lintels damaged in transit should not be used. 2. Check the correct lintel is being installed. 3. All bearing areas should be prepared using full
F IRE TEST
bricks/blocks or padstones. 4. Lintels should be installed with a minimum 150mm end
NOTCHED LINTEL
CRANKED LINTELS
The L1 profile has been subjected to two fire tests by:
bearing at both ends, be fully bedded on bricklaying
a. The fire research station, Boreham Wood.
mortar and levelled both longitudinally and horizontally.
b. The Warrington Fire Research Station.
When limited end bearings are unavoidable, check with
In both cases one hour fire rating was achieved with the
IG technical office for suitability.
load successfully supported 48 hours later. Further details available on request.
5. Open back lintels should be filled with masonry in accordance with BS 5977 and a full block built in
END PLATED LINTELS
STEPPED LINTELS
DURABILITY
through the end bearing and allowed to cure before continuing building.
The service life of lintels will be equal to the life expectancy of the building when installed with a flexible DPC and within
6. The inner and outer leaves supported by the lintel should be raised together to avoid excessive eccentricity of
Enquiries for Special Lintels should be faxed to: 01633 486495 Technical information continued over page
32
33
loading. Masonry above lintels should be allowed to cure before applying floor or roof loads. If this is not achievable, temporary support in the form of props should be used. NHBC guidelines propose no greater than a 1m span for props during construction. 7. When installing concrete floor units or other heavy
10. Masonry should not overhang any flange by more than 25mm. 11. The lintel toe must project beyond the window/door
indicates the degree of stiffness the lintel will exhibit under a given load and span. The greater the value of Ixx, the less
flange and the frame to avoid moisture penetration.
Zxx - This is the section modulas and is used when ●
maximum bending stresses that the lintel section can be 12. When the underside of a lintel is exposed, its appearance
loading. Temporary support in the form of props is
can be enhanced by the addition of lintel soffit cladding,
advisable if there is a limited amount of masonry to the
supplied in white and brown, or by the application of a
Web buckling - This applies to box lintels and indicates the
outer leaf. Pre-cast floor units should be laid on a mortar
good quality etch primer and paint after installation.
maximum end reaction that the lintel can sustain before the
●
Handling, Storage & Disposal ●
●
QUALITY ASSURANCE ●
To help ensure optimum performance and economy from British and European Standards IG lintels are designed to
The service includes:
meet all relevant standards: for manufacture BS 5977 EN 10142 1991 Specification for continuously hot dip zinc coated low carbon steel sheet and strip and for stainless
procedure followed does not compromise the loading/
if future revisions to the specifications are be avoided:
steel BS EN 10088-2 1.4301 (304S15) cold rolled stainless
installation restrictions applicable to the products.
a. Plans including dimensions (1:50 scale preferable)
alloys
●
Agrément Certificate No 97/3343:
COSHH
The BBA have assessed the following lintels which are covered
We are not aware of any risk to the person, arising from
by the certificate: L1/S 50, L1/S 75, L1/S 100, L1/HD 50,
chemicals or any other substances present on or in our products.
L1/HD 75, L1/HD 100, L1/XHD 50, L1/XHD 75, L1/XHD 100,
Part L Compliance
c. Sections (1:50 scale preferable) d. Floor joist layouts or PC concrete floor layouts and loadings (1:50 scale preferable)
f.
Any other relevant information, such as steelwork layouts etc.
L1/S WIL 50, L1/S WIL 75, L1/S WIL 100, L1/HD WIL 50, L1/HD WIL 75, L1/HD WIL 100, L1/XHD WIL 50, L1/XHD WIL 75, L1/XHD WIL 100, L1/ST 50, L1/ST 75, L1/ST 100, L1/ST HD 50, L1/ST HD 75, L1/ST HD 100, L1/ST XHD 50,
masonry between the flange and the application level of
2. Provision of lintel location drawings.
any form of loading.
3. Provision of structural calculations for Building Regulation
BOX 140, BOX 200, L5/50, L5/75 and L5/100. Quality Control
9. In accordance with BS 5628 and NHBC requirements,
approval. We reserve the right to supply these only in
Manufacturing facilities and quality control systems at
all external wall lintels MUST be installed with a flexible
reply to a written request from a Building Control Authority
Cwmbran have been successfully assessed by the British
damp proof course with the exception of those
or upon the receipt of an order/letter of intent.
Standards quality inspectorate and the company has been
adequately protected by an eaves overhang or similar
4. Advice on the use of lintels in uncommon situations
form of protection. Stop ends should be provided as
such as reduced end bearings, point loads and the like. 5. Design and detailing of special lintels, see special lintel
No special disposal requirements, subject to local restrictions.
Following numerical analysis, the British Board of Agrément has concluded that IG’s steel lintels with continuous base plates do comply with the cold bridging requirements of Part L of the Building Regulations.
L1/ST XHD 75, L1/ST XHD 100, L1/S WOL 50, L1/S WOL 75, L1/S WOL 100, L7/50, L8/50, L9, BOX 75, BOX 100,
Environmental The expanded polystyrene core used in IG Lintels has an ozone depletion potential of zero.
awarded a Quality Assurance certificate to BS EN ISO 9002.
FASTRACK DATABASE FOR CAD USERS
page 29.
Proprietary stop ends should be used or alternatively
Tabular information in this brochure includes CAD Codes
the DPC should extend to the edge of the front toe and
TERMINOLOGY USED IN TABLES
that relate to the IG Fastrack Database. This allows architects and specifiers using computer aided design instant access
coursing) to allow formation of an integral stop end at a suitable perp joint. Weepholes should be used in the
Total UDL - This is the safe uniformly distributed load and
external masonry leaf to drain moisture away from the
indicates the total design load spread evenly along the
cavity. A minimum of 2 weepholes should be provided for
length of the lintel including an approximate safety factor.
to IG steel lintel details to produce complete and accurate drawings quickly and easily. Supplied on CD-ROM, the Fastrack Database is available in AutoCAD and DXF format. Specifiers can obtain free
each lintel, generally at 450mm centres. Weepholes can be
34
Where structural products are to be removed from an
These drawings should include the following information
etc. (1:50 scale preferable)
50 - 150mm beyond the end of the lintel (depending on
●
1. Preparation of lintel schedules from drawings supplied.
e. Roof layout, showing positions of girder trusses
avoid moisture entering the cavity near the reveals.
including proper washing of hands after contact.
existing installation, care must be taken to ensure that the
b. Elevations (1:50 or 1:100 scale)
specified by BS 5628 Part 3 1985 and the NHBC to
Some products may have a film of mineral cutting fluid after manufacture, therefore carry out personal hygiene
lintel specifications, IG provide a free expert advisory service.
Part 2:1983 and BS EN 845–2:2003; for galvanised steel BS
Footer plate
Protective gloves should be worn when handling or cutting material to prevent injury from sharp edges.
8. Point loads should not be applied directly to lintel
Prop
Handling of materials must comply with the Manual Handling Operation Regulations 1992.
webs fail by buckling.
TECHNICAL ADVISORY SERVICE
Lintel Header plate
Structural products must be installed in accordance with their specific instructions to prevent the risk of failure.
subjected to without exceeding the design stress.
masonry. Floor units should not be dragged into position.
flanges. Lintels should have a minimum of 150mm
There may be a risk of cuts from sharp edges or projections.
calculating the effects of uneven loading. It indicates the
components, care should be taken to avoid shock
bed to avoid load concentrations at high points in the
!
Hazard Identification
frame and it is recommended that a flexible sealing compound is used between the underside of the lintel
HEALTH AND SAFE TY
the lintel will deflect.
formed with proprietary weep vents or by leaving perp
Ixx - Represents the moment of inertia or the second
copies directly from IG’s Technical Services Department
joints open.
moment of area and is a characteristic of the lintel shape. It
01633 486499.
35
Cavity Trays A UNIQUE SINGLE ELEMENT CAVITY TRAY SYSTEM
GABLE ABUTMENT SYSTEM
that are folded on site to form right-angled corners. The
When a stepped or staggered gable abutment is formed the
75mm or 100mm cavity widths and incorporate mastic sealant
status of the external skin below the roof line changes to that
strips for overlapping areas.
trays are pre-creased and incorporate adjustment for 50mm,
of an internal skin. Accordingly, every gable abutment must be constructed so as to prevent dampness and rainwater from penetrating below the abutting roof line.
REFURBISHMENT SYSTEM The IG Refurbishment Cavity Trays System has been
The IG Gable Abutment Cavity Tray forms a stepped cavity
specifically developed to facilitate both the insertion of a new
dpc which is incorporated into the building during bricklaying.
tray into an existing wall and the repair or alteration of an
The completed structure is ready to receive roof lead flashing
existing damp proof course.
in the conventional way. WHERE TO USE THE IG CAVITY TRAY - TYPE GA Where a new lean-to extension meets an existing building, Manufactured from polypropylene, the IG Gable Abutment
the original external wall becomes an internal partition
Cavity Tray is available in three sizes to suit all roof pitches up
below the roof line and must be protected from dampness
to 60°. It is suitable for use in all brick, block and timber-
and the penetration or rainwater. Similarly, when a flat roof
framed constructions, the large bridging piece catering for
is resurfaced with added insulation, or is reconstructed as an
cavity widths from 50mm to 100mm.
inverted roof with top paving, the roof level may be raised
Supplied flat, the pre-creased trays allow for easy on-site
and thus require the skirting and its corresponding damp
folding to the required shape - catchment, left and right hand
proof course to be lifted.
or ridge tray. A locating lip facilitates the accurate placement
In addition, existing cavity trays which have been poorly
of trays during bricklaying.
constructed or have rotted allowing water to leak through must be replaced.
CALCULATING QUANTITIES The single-element system makes the calculation of quantities
THE IG CAVITY TRAY - TYPE RFT
very simple. Whether you are building with bricks or blocks
Available off-the-shelf in flat-packs, the IG Refurbishment
the rule is the same: you require one cavity tray per course
Tray combines ease of handling, transportation and use
per slope. On a double slope roof this calculation will give you
with complete effectiveness. It meets all current Building
an extra tray that can be used to lengthen the ridge tray if
Regulations and NHBC requirements. Manufactured from
required.
polypropylene, the IG Refurbishment Tray is 620mm wide
SIZES AND ROOF PITCHES
timber-framed constructions. The large bridging piece caters
The IG Gable Abutment Cavity Tray is available in three sizes
for cavity widths from 50mm to 100mm.
as detailed below. Trays are supplied in shrink-wrapped flat
Supplied flat, the pre-creased trays allow for easy on-site
packs in the quantities indicated or as single items.
folding to the required shape including forming left and right
by 280mm deep and is suitable for use in all brick, block and
Unique Products with Outstanding Benefits:
GABLE ABUTMENT
• Available off-the-shelf in easy-to-handle flat packs • Easy to calculate quantities, transport, use and adapt • Three sizes cover all roof pitches and cavity widths • Impact, tear and abuse resistant thermostable polypropylene 0.8mm thick • Compatible with all building materials • Resistant to acid, alkali and sulphate
REFURBISHMENT
• Meets all current Building Regulations and NHBC requirements • Will last the lifetime of the building
36
Outer Leaf Construction
hand end stops. A locating lip facilitates accurate placement
Roof Pitch
Code
Size In mm
Packs of:
during installation and the mastic sealant strip (protected by
Brickwork Blockwork
22.5°-60° more than 45°
GA1
375 x 310
50 or 10
release paper) ensures easy and watertight overlap jointing.
Brickwork Blockwork
15°-30° 35°-45°
GA2
525 x 310
5
SPECIFYING
Brickwork Blockwork
less than 15° 25°-40°
GA3
675 x 310
5
When specifying, the following wording is recommended: “Provide IG Refurbishment Cavity Tray System from
Note: All packs contain full installation instructions and folding instructions are printed on each tray
IG Limited, Cwmbran, Gwent NP44 1XY (01633 486486) to be installed as manufacturer’s instructions. Trays to be folded,
INTERNAL/EXTERNAL CORNERS
as instructions on tray, to form left and right hand stop ends”.
Flat-packed foldable corners complete the IG Gable Abutment
Refurbishment Cavity Trays
• The most cost-effective cavity tray system available
Cavity Tray System. Both internal (GAIC) and external (GAEC)
• Available from a national network of stockists
corner trays comprise factory-jointed two-piece assemblies
Code RFT
Size in mm 620 x 280
Packs of: 10
37
Specify Keylite
Also available from
The UK’s Only Indigenous
Centre Pivot Window
Top Hung Window
Fire Escape/Access Window
Conservation Window
Flat Roof System
White Finish Window
Electric Operation Windows & Blinds
Combination Flashings & Glazing Options
Roof Window Manufacturer
Standard Window Sizes (nominal wxh)mm Thermal
550x780
550x980
660x1180
780x980
780x1180
780x1400
940x1600
1140x1180
1340x980
Spec
01T
02T
03T
04T
05T
06T
07T
08T
09T
Spec
01HT
02HT
03HT
04HT
05HT
06HT
07HT
08HT
09HT
Toughened glazing system (28mm pane ‘Low E’Gas Filled) U = 1.4 w/m2k
Thermo-Plus
Laminated toughened glazing system with a UV filter (28mm pane ‘Low E’Gas Filled) U = 1.4 w/m2k
*U value relates to complete installed window
NOTE: Flashings available
Integral Blind Window The Roof Window... with the blind sealed inside the glass! Blind is permanently sealed within the double glazing unit Totally dust free environment Requires NO CLEANING Always appears new Is protected from damage Provides enhanced sun-shading Improves the u-value of the sealed unit Is factory-fitted Available for entire window range i.e. Centre Pivot, Top Hung, Fire Escape / Access and Conservation Windows Is magnetically operated
38
For more information
visit www.keylite.co.uk
39