STRAUMANN 速 BoneCeramic BUILDING A FOUNDATION FOR SUCCESS
ED
BoneC eramic
LY
Strau mann 速
CLINICA L
* CLINICA L
OCUMEN T
* ED
D LY
U DOC MENT
YOUR FORMULA DESIGNED FOR SUCCESS – BONE VITALITY AND VOLUME IN ONE PRODUCT Vital bone tissue regeneration builds a foundation for the success of the osseointegration of a dental implant and the functional regrowth of periodontal structures. The specific formulation of Straumann® BoneCeramic has been designed to support patients vital bone regeneration, while also restoring and preserving bone volume, which is critical for the esthetic result.
TCP
Hydroxylapatite (HA) and tricalcium phosphate (TCP) are both added during synthesis to form an homogeneous biphasic calcium phosphate.
HA
40 % TCP
60 % HA
Fast resorption
Slow resorption
[A]
[B]
REPLACEMENT BY VITAL BONE
BONE VOLUME PRESERVATION
TCP
HA BONE VITALITY AND VOLUME IN ONE PRODUCT
Straumann® BoneCeramic is a 100 % synthetic bone graft substitute with excellent handling characteristics. The 90 % porosity allows for blood vessels and vital bone in-growth through the material, conferring Straumann® BoneCeramic osteoconductive properties.
THE VITAL TISSUE YOU WANT AROUND YOUR IMPLANT Straumann® BoneCeramic gradually resorbs and is substituted by the patient’s own vital bone. A good bone foundation is key for a successful long-term osseointegration of the dental implant.
[A]
p 28.35 % average newly formed mineralized bone with Straumann® BoneCeramic versus 22.27 % with bovine bone mineral in sinus (p = 0.6024)2* p Trend of increase in bone formation over healing time with Straumann® BoneCeramic2 p 100 % bone vitality in all harvested tissue biopsies2
NMB SBC
* Data collection between 6 and 8 months post-augmentation Straumann® BoneCeramic intergated into patient`s new bone. Stevenel`s blue and Van Gieson`s picro fuchsin, magnification X 200. Image by Prof. Dr. J. Froum. NMB: New mineralized bone SBC: Straumann® BoneCeramic Osteoid: green staining
THE BONE VOLUME YOU NEED FOR AN ESTHETIC RESULT Straumann® BoneCeramic is designed to restore and preserve the patient‘s bone volume, which is critical for the esthetic result. Straumann® BoneCeramic
mm
Bovine bone mineral
p Nearly 50 % less reduction in the bucco-lingual ridge dimension with Straumann® BoneCeramic versus bovine bone mineral5** p Equivalent width of the buccal and palatal/lingual bone plate5 p Equivalent interproximal height of the alveolar bone crest5
Width of the alveolar ridge
10 8 6
-1.1±1 mm
-2.1±1 mm
4 **Data collection at 8 months post-augmentation
2 0 at surgery
8 mos. post-augm.
at surgery
8 mos. post-augm.
[A] Reproduction authorized by Int J Periodontics Restorative Dent
[B] Images by Dr. N. Mardas and Prof. N. Danos
EXCELLENT HANDLING AND PEACE OF MIND p 100 % synthetic, eliminating any risk for disease transmission p Straumann® BoneCeramic rapidly absorbs fluids and thus adheres to the application instrument and subsequently to the bony defect
BROAD RANGE OF INDICATIONS
Tooth extraction sites
Alveolar ridge bony defects
Sinus floor elevations
Studies on Straumann® BoneCeramic 1. Cordaro L. et al. Clin. Oral. Impl. Res. 2008; 19: 796-803 2. Froum S. J.et al. Int. J. Periodontics Restorative Dent. 2008; 28: 273-281 3. Artzi Z. et al. Clin. Oral Impl. Res. 2008; 19: 686-692 4. van Assche N. et al. Poster EAO 2007. Data on file (study CR 04/05) 5. Mardas N. et al. Poster IADR 2008. Data on file (study CR 03/05) 6. Friedmann et al. Clin.Oral Impl. Res. 2009; 20: 708-14 7. Zafiropoulos 2007. Periodontol. 2007; 78: 2216-2225 8. Jensen et al. J Biomed Mater Res B Appl Biomater. 2009; 90(1): 171-81 9. Jensen S. S. et al. Clin. Oral. Impl. Res. 2007; 18: 752-760 10. Schwarz F. et al. Int. J of Oral & Maxillofacial Surgery 2007; 36: 1198-1206
Dehiscences
Intrabony defects/furcations
Indications Sinus floor elevation Sinus floor elevation Sinus floor elevation Dehiscences Ridge dimension preservation Sinus floor elevation and lateral augmentation Periodontal defects Preclinical study, standardized defects in mandible Preclinical study, standardized defects in mandible Preclinical study, dehiscences
A STANDARD FOR SUCCESS “We have now used BoneCeramic just over 1,000 times and it has become an extremely valuable aid when augmentation measures are called for. Because of its fully synthetic components, constant volume and very high success rate of up to 99.6 %, it has become a standard here.“ (Dr. A. Stricker) “My choice of SBC for the graft material is based on its osteoconductive and space-maintaining properties, necessary for the long-term support of the hard and soft peri-implant tissues. The degradability of bone ceramic is a desired property, allowing for gradual substitution of the graft with vital bone, capable of achieving osseointegration.“ (Dr. B. Levin)
© Institut Straumann AG, 2009. All rights reserved. Straumann® and/or other trademarks and logos from Straumann® that are mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved.