CHILLER CATALOGUE
Summit Matsu Chillers June 2013 standard chiller range (please contact us for any non-standard requirement on 1300 244 553)
Table of Contents: CHILLER RANGE: UMWC-8-1KW TO 3KW CADET SERIES
2
CHILLER RANGE: UMWC-8-1.0KW TO 6KW
3
CHILLER RANGE: UMWC-8-7.0KW TO 12KW
5
CHILLER RANGE: UMWC-8-18KW TO 36KW
6
CHILLER RANGE: UMWC-8-46KW TO 76KW
7
CHILLER RANGE: UMWC-8-85KW TO 130KW
8
CHILLER RANGE: UMWC-7-3KW TO 6KW
9
CHILLER RANGE: UMWC-7-7KW TO 16KW
10
CHILLER RANGE: USDA-7-22KW TO 45KW (CAS17)
11
CHILLER RANGE: USDA-7-55KW TO 85KW (CAS17)
12
CHILLER RANGE: USDA-7-75KW TO 140KW
13
CHILLER PRODUCT: COLD SPA CHILLER
14
CHILLER RANGE: USMC-6-120KW TO 240KW – SCROLL OPTION
15
CHILLER RANGE: USMC-6-220KW TO 300KW – SCREW OPTION
16
CHILLER RANGE: USMC-6-360KW TO 450KW – SCREW OPTION
17
CHILLER RANGE: USMC-6-500KW TO 900KW – SCREW OPTION
18
NOTES:
19
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
1
CHILLER CATALOGUE Chiller Range: UMWC-8-1kW to 3kW Cadet Series Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
UMWC-8-1 Cadet
UMWC-8-1.5 Cadet
UMWC-8-2.0 Cadet
UMWC-8-3 Cadet
1 0 5
1.5 0 5
2 0 5
2.9 0 5
700 455 475
700 455 475
700 455 475
700 455 475
35 41 Cas 3 Painted
35 41 Cas 3 Painted
35 41 Cas 3 Painted
35 41 Cas 3 Painted
1 Air Cooled Aluminium Coils in Tank
1.5 Air Cooled Aluminium Coils in Tank
2 Air Cooled Aluminium Coils in Tank
2.9 Air Cooled Aluminium Coils in Tank
Cooling Only Rotary 1 None
Cooling Only Rotary 1 None
Cooling Only Rotary 1 None
Cooling Only Rotary 1 None
R407C 1.5 Axial 45
R407C 1.7 Axial 45
R407C 2 Axial 45
R407C 2 Axial 45
230V 50Hz 1Ph 5.8
230V 50Hz 1Ph 7.0
230V 50Hz 1Ph 8
230V 50Hz 1Ph 10.0
6.8 20.4 Yes Digital Thermostat
7.8 23.4 Yes Digital Thermostat
9 27 Yes Digital Thermostat
12.9 38.7 Yes Digital Thermostat
Yes Yes None 1
Yes Yes None 1
Yes Yes None 1
Yes Yes None 1
Yes 0.02
Yes 0.05
Yes 0.1
Yes 0.12
5M / 50kPa Manual make-up 6L Yes
5M / 50kPa Manual make-up 6L Yes
5M / 50kPa Manual make-up 6L Yes
5M / 50kPa Manual make-up 6L Yes
25 25 No
25 25 No
25 25 No
25 25 No
No
No
No
No
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
2
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: UMWC-8-1.0kW to 6kW Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
UMWC-8-1.0
UMWC-8-2.0
UMWC-8-3
UMWC-8-6
1.0 0 5
2.0 0 5
2.9 0 5
5.8 0 5
760 600 1220 69
760 600 1220 75
760 600 1220 96
760 600 1220 98
176 Cas 4 Painted
187 Cas 4 Painted
197 Cas 4 Painted
198 Cas 4 Painted
1.0 Air Cooled Aluminium Coils in Tank Cooling Only Rotary
2.0 Air Cooled Aluminium Coils in Tank Cooling Only Rotary
3.0 Air Cooled Aluminium Coils in Tank Cooling Only Rotary
5.8 Air Cooled Aluminium Coils in Tank Cooling Only Rotary
1 None R407C 1.5
1 None R407C 2
1 None R407C 2
1 None R407C 2.5
1 - Axial 45
1 - Axial 45
1 - Axial 58
1 - Axial 58
230V 50Hz 1Ph
230V 50Hz 1Ph
230V 50Hz 1Ph
230V 50Hz 1Ph
8.3 9.4 38.7
10.5 11.4 46.2
14.4 15.4 46.5
14.5 15.6 61.5
Yes Digital Thermostat Yes Yes None
Yes Digital Thermostat Yes Yes None
Yes Digital Thermostat Yes Yes None
Yes Digital Thermostat Yes Yes None
1
1
1
1
Yes 0.1 + bypass
Yes 0.14 + bypass
Yes 0.17 + bypass
Yes 0.28 + bypass
10M / 1bar Yes 60./L Yes
10M / 1bar Yes 60./L Yes
10M / 1bar Yes 60./L Yes
10M / 1bar Yes 60./L Yes
25 25 Yes - Manual No
25 25 Yes - Manual No
25 25 Yes - Manual No
25 25 Yes - Manual No
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
3
CHILLER CATALOGUE
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
4
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: UMWC-8-7.0kW to 12kW
Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
UMWC-8-7.0
UMWC-8-9
UMWC-8-12
7.3 0 5
9 0 5
12 0 5
990 830 1220 135
990 830 1220 155
990 830 1220 165
225 Cas 5 Painted
245 Cas 5 Painted
255 Cas 5 Painted
7.3 Air Cooled Aluminium Coils in Tank Cooling Only Hermetic Scroll 1
9 Air Cooled Aluminium Coils in Tank Cooling Only Hermetic Scroll 1
12 Air Cooled Aluminium Coils in Tank Cooling Only Hermetic Scroll 1
None R407C 3.0 1 - Axial
None R407C 3.5 1 - Axial
None R407C 4 1 - Axial
61
61
63
230V 50Hz 1Ph 17 18.1
230V 50Hz 1Ph 18 19.7
400V 50Hz 3Ph 12 13.9
74.1 Yes Digital Thermostat Yes
102 Yes Digital Thermostat Yes
52.2 Yes Digital Thermostat Yes
Yes None 1
Yes None 1
Yes None 1
Yes 0.35 + bypass 10M / 1bar Yes
Yes 0.43 + bypass 10M / 1bar Yes
Yes 0.57 + bypass 10M / 1bar Yes
120/L Yes 25 25
120/L Yes 25 25
120/L Yes 25 25
Yes - Manual No
Yes - Manual No
Yes - Manual No
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
5
CHILLER CATALOGUE Chiller Range: UMWC-8-18kW to 36kW Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
UMWC-8-18 18 0 5
UMWC-8-22
1530 760 1850 600 1100 Cas 6 Painted 18 Air Cooled Aluminium Coils in Tank Cooling Only Scroll 1 None R407C 6 Axial 55 400V 50Hz 3Ph 25 27.1 110
22
UMWC-8-28 28
UMWC-8-36 36
0 5
0 5
0 5
1530
1530
1530
760 1850 600 1100
760 1850 650 1150
760 1850 720 1220
Cas 6 Painted
Cas 6 Painted
Cas 6 Painted
22 Air Cooled Aluminium Coils in Tank Cooling Only Hermetic Reciprocating 1 None R407C
27 Air Cooled Aluminium Coils in Tank Cooling Only Hermetic Reciprocating 1 None R407C
36 Air Cooled Aluminium Coils in Tank Cooling Only Semi Hermetic Scroll 1 None R407C
6 Axial 55
7 Axial 58
8.5 Axial 58
400V 50Hz 3Ph 28 32.1 150
400V 50Hz 3Ph 34 38.1 216
400V 50Hz 3Ph 41 46.2 244
Yes Micro Processor
Yes Micro Processor
Yes Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes 0.9 + bypass 10M / 1bar
Yes 1.1 + bypass 10M / 1bar
Yes 1.3 + bypass 10M / 1bar
Yes 1.7 + bypass 10M / 1bar
Yes 200./L Yes 32
Yes 200./L
Yes 200./L
Yes 200./L
Yes 32
Yes 32
Yes 32
32 Yes
32 Yes
32 Yes
32 Yes
No
No
No
No
Micro Processor
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
6
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: UMWC-8-46kW to 76kW Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
UMWC-8-46 46
UMWC-8-56 56
UMWC-8-66 66
UMWC-8-76 76
0 5
0 5
0 5
0 5
1485
1485
1485
1485
1595 2075 860 1350
1595 2075 880 1380
1595 2075 950 1450
1595 2075 1000 1500
Cas 7 Painted
Cas 7 Painted
Cas 7 Painted
Cas 7 Painted
46 Air Cooled Aluminium Coils in Tank Cooling Only Semi-Hermetic Scroll 1 Nil
56 Air Cooled Aluminium Coils in Tank Cooling Only Semi-Hermetic Reciprocating 1 Step 50 / 100
66 Air Cooled Aluminium Coils in Tank Cooling Only Semi-Hermetic Reciprocating 1 Step 66/ 100
76 Air Cooled Aluminium Coils in Tank Cooling Only Semi-Hermetic Reciprocating 1 Step 66 / 100
R407C 10 Axial 61
R407C 10.5 Axial 63
R407C 11 Axial 65
R407C 12 Axial 70
400V 50Hz 3Ph 35 55.2
400V 50Hz 3Ph
400V 50Hz 3Ph
400V 50Hz 3Ph
51 65.2
60 84.2
74 102.2
285 Yes
202 Yes
225 Yes
257 Yes
Micro Processor
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 2
Yes Yes Gen Fault / Remote Start & Stop 2
Yes Yes Gen Fault / Remote Start & Stop 2
Yes 2.2
Yes 2.8
Yes 3.3
Yes 3.6
10M / 1bar Yes 500./L Yes
10M / 1bar Yes 500/L Yes
10M / 1bar Yes 750./L Yes
10M / 1bar Yes 750./L Yes
50 50 Yes No
50 50 Yes
50 50 Yes
50 50 Yes
No
No
No
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
7
CHILLER CATALOGUE Chiller Range: UMWC-8-85kW to 130kW UMWC-8-85 85
UMWC-8-100 100
UMWC-8-110 110
UMWC-8-130
0 5
0 5
0 5
0 5
3000
3000
3000
3000
1595 2075 1020 1520
1595 2075 1300 2050
1595 2075 1320 2070
1595 2075 1320 2150
Cas 8 Painted
Cas 8 Painted
Cas 8 Painted
Cas 8 Painted
Evaporator Design Unit Operation
85 Air Cooled Aluminium Coils in Tank Cooling Only
100 Air Cooled Aluminium Coils in Tank Cooling Only
110 Air Cooled Aluminium Coils in Tank Cooling Only
130 Air Cooled Aluminium Coils in Tank Cooling Only
Compressor Style
Screw
Screw
Screw
Screw
1 Step 50 / 75 / 100
1 Step 50 / 75 / 100
1 Step 50 / 75 / 100
1 Step 50 / 75 / 100
R407C 20 Axial 78
R407C 23 Axial 78
R407C 25 Axial 85
R407C 30 Axial 85
400V 50Hz 3Ph 80 102.9
400V 50Hz 3Ph
400V 50Hz 3Ph
400V 50Hz 3Ph
90 114.4
96 142.2
114 162.1
321 Yes
351 Yes
344 Yes
362 Yes
Micro Processor
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 3
Yes Yes Gen Fault / Remote Start & Stop 3
Yes Yes Gen Fault / Remote Start & Stop 3
Yes Yes Gen Fault / Remote Start & Stop 3
Yes 4.1 + bypass
Yes 4.8 + bypass
Yes 5.3 + bypass
Yes 6.2 + bypass
10M / 1bar Yes 750./L Yes
10M / 1bar Yes 750/L Yes
10M / 1bar Yes 1000./L Yes
10M / 1bar Yes 1000./L Yes
75 75 Yes No
75 75 Yes
75 75 Yes
75 75 Yes
No
No
No
Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Reset External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
130
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
8
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: UMWC-7-3kW to 6kW Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW)
UMWC-7-3.0 2.9
UMWC-7-6.0 5.8
7 12
7 12
760
760
600 1220 69 79
600 1220 98 108
Cas 4 Painted
Cas 4 Painted
Evaporator Design Unit Operation
2.9 Air Cooled Aluminium Co-Axial or Plate Cooling Only
5.8 Air Cooled Aluminium Co-Axial or Plate Cooling Only
Compressor Style
Rotary
Rotary
1 None
1 None
R407C 2.5 Axial 45
R407C 2.9 Axial 58
230V 50Hz 1Ph 11.6 12.6
230V 50Hz 1Ph 12 13.6
Comp Time Delay Auto Restart
26.4 Yes Digital Thermostat Yes Yes
41 Yes Digital Thermostat Yes Yes
External Controls
None
None
1
1
No 0.14
No 0.28
10M / 1bar No No 25
10M / 1bar No No 25
25 No Yes
25 No Yes
Condenser Design
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type
Control Stages Water Pump In-built Water Flow (l/s) Required Rated Pump Head (min) Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
9
CHILLER CATALOGUE Chiller Range: MWC-7-7kW to 16kW Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW)
UMWC-7-7 7.3
UMWC-7-9 9
UMWC-7-11 11
UMWC-7-14 14
UMWC-7-16 16
7 12
7 12
7 12
7 12
7 12
990
990
990
990
990
680 1220
680 1220
680 1220
680 1220
680 1220
110 120
115 125
120 130
125 135
130 140
Cas 5 Painted
Cas 5 Painted
Cas 5 Painted
Cas 5 Painted
Cas 5 Painted
Evaporator Design Unit Operation
7.3 Air Cooled Aluminium Co-Axial / Plate Cooling Only
9 Air Cooled Aluminium Co-Axial / Plate Cooling Only
11 Air Cooled Aluminium Co-Axial / Plate Cooling Only
14 Air Cooled Aluminium Co-Axial / Plate Cooling Only
16 Air Cooled Aluminium Co-Axial / Plate Cooling Only
Compressor Style
Hermetic Scroll
Hermetic Scroll
Hermetic Scroll
Hermetic Scroll
Hermetic Scroll
1 None
1 None
1 None
1 None
1 None
R407C 2.5 Axial 55
R407C 2.7 Axial 55
R407C 3.0 Axial 55
R407C 3.2 Axial 55
R407C 3.5 Axial 55
230V 50Hz 1Ph 12 13.3
230V 50Hz 1Ph 13 15.3
400V 50Hz 3Ph 7 9.1
400V 50Hz 3Ph 8 11.1
400V 50Hz 3Ph 9 11.1
Comp Time Delay Auto Restart
40 Yes Digital Thermostat Yes Yes
46 Yes Digital Thermostat Yes Yes
28 Yes Digital Thermostat Yes Yes
34 Yes Digital Thermostat Yes Yes
36 Yes Digital Thermostat Yes Yes
External Controls
None
None
None
None
None
1
1
1
1
1
No 0.35
No 0.43
No 0.53
No 0.67
No 0.76
10M / 1bar No No 25
10M / 1bar No No 25
10M / 1bar No No 25
10M / 1bar No No 25
10M / 1bar No No 25
25 No Yes
25 No Yes
25 No Yes
25 No Yes
25 No Yes
Condenser Design
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA PLA LRA Auto Program Controller Controller Type
Control Stages Water Pump In-built Water Flow (l/s) Required Rated Pump Head (min) Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
10
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: USDA-7-22kW to 45kW (Cas17) USDA-7-22-Cas17 22
USDA-7-28-Cas17 28
USDA-7-38-Cas17 38
USDA-7-45-Cas17
7 12
7 12
7 12
7 12
1530
1530
1530
1530
760 1850
760 1850
760 1850
760 1850
860 865 Cas 17 Painted
860 865 Cas 17 Painted
860 865 Cas 17 Painted
860 865 Cas 17 Painted
Evaporator Design Unit Operation
22 Air Cooled Aluminium Plate Cooling Only
28 Air Cooled Aluminium Plate Cooling Only
38 Air Cooled Aluminium Plate Cooling Only
45 Air Cooled Aluminium Plate Cooling Only
Compressor Style
Hermetic Scroll
Semi-Hermetic Scroll
Semi-Hermetic Scroll
Semi-Hermetic Scroll
1 None R407C 6
1 None R407C 6.5
1 None R407C
1 None R407C
8
8.5
Axial 63
Axial 65
Axial 66
Axial 66
400V 50Hz 3Ph
400V 50Hz 3Ph
400V 50Hz 3Ph
400V 50Hz 3Ph
19 23.7 126 Yes
22 28.7 137 Yes
29 34.7 204 Yes
35 40.7 232 Yes
Micro Processor
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes
No 1.1 20 No
No
No
No
1.3 20 No
1.8 20 No
2.2 20 No
No 32 32 No
No 32 32 No
No 40 40 No
No 40 40 No
Terminals
Terminals
Terminals
Terminals
Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C)
45
Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Required Pressure Drop (kPa) Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
Gen Fault / Remote Start & Stop 1
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
11
CHILLER CATALOGUE Chiller Range: USDA-7-55kW to 85kW (Cas17) USDA-7-55-Cas17 55
USDA-7-65-Cas17 65
USDA-7-75-Cas17 75
USDA-7-85-Cas17
7 12
7 12
7 12
7 12
1530
1530
1530
1530
760 1850 860 865
760 1850 860 865
760 1850 860 865
760 1850 860 865
Cas 17 Painted
Cas 17 Painted
Cas 17 Painted
Cas 17 Painted
Evaporator Design Unit Operation
55 Air Cooled Aluminium Plate Cooling Only
65 Air Cooled Aluminium Plate Cooling Only
75 Air Cooled Aluminium Plate Cooling Only
85 Air Cooled Aluminium Plate Cooling Only
Compressor Style
Semi-Hermetic Scroll
Semi-Hermetic Scroll
Semi-Hermetic Scroll
Semi-Hermetic Scroll
1 None
1 None R407C
2 None R407C
2 None R407C
10 Axial 67
12 Axial 72
16 Axial 72
400V 50Hz 3Ph 40 44.7
400V 50Hz 3Ph
400V 50Hz 3Ph
400V 50Hz 3Ph
45 49.7
72 77.7
80 85.4
273 Yes
273 Yes
396 Yes
424 Yes
Micro Processor
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
Yes Yes Gen Fault / Remote Start & Stop 1
No 2.6
No
No
No
3.1
3.6
4.1
20 No No 50
20 No No 50
20 No No 50
20 No No 50
50 No Terminals
50 No Terminals
50 No Terminals
50 No Terminals
Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Required Pressure Drop (kPa) Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
R407C 8.5 Axial 67
85
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
12
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: USDA-7-75kW to 140kW Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) Full load Amps (Comp + Fan) Full load Amps (Pump) Total Full Amps Start Amps (excl Pump) Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
USDA-7-95 95 7 12
USDA-7-125 125 7 12
USDA-7-140 140 7 12
1480 1310 2020
1480 1310 2020
1480 1310 2020
490 510 Cas 1 Painted
510 530 Cas 1 Painted
525 545 Cas 1 Painted
95 Air Cooled Aluminium Vertical Shell and Tube Cooling Only
125 Air Cooled Aluminium Vertical Shell and Tube Cooling Only
140 Air Cooled Aluminium Vertical Shell and Tube Cooling Only
Recip or Screw
Screw
Screw
1
1
1
Step 100 / 50 R407C 14 Axial
Step 100 / 75 / 50 R407C 20 Axial
Step 100 / 75 / 50 R407C 23 Axial
78
78
78
400V 50Hz 3Ph 91.8
400V 50Hz 3Ph 115.8
400V 50Hz 3Ph 117.8
91.8 275.4 Yes
115.8 347.4 Yes
117.8 353.4 Yes
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 2
Yes Yes Gen Fault / Remote Start & Stop 3
Yes Yes Gen Fault / Remote Start & Stop 3
No 4.5 Not included No
No 6 Not included No
No 6.7 Not included No
No No 75 75
No No 75 75
No No 75 75
No Terminals
No Terminals
No Terminals
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
13
CHILLER CATALOGUE Chiller Product: Cold Spa Chiller Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW)
UMWC-7-7.0-Spa 7.3 7 9 990 830 1220 115 125 Cas 5 Painted 7.3
Condenser Design
Air Cooled Aluminium
Evaporator Design Unit Operation
Stainless Plate Cooling Only
Compressor Style
Hermetic Scroll
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) Full load Amps (Comp + Fan) Full load Amps (Pump) Total Full Amps Start Amps (excl Pump) Auto Program Controller Controller Type
1 None R407C 3 Axial 61 230V 50Hz 1Ph 11 14.5 16 45 Yes Digital Thermostat
Comp Time Delay Auto Restart
Yes Yes
External Controls
None
Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head (min) Tank and Water make up Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
** Includes all water piping suitable for swimming pool / spa water
1 Yes 1.0 10M / 1bar No No Yes 25 25 No Yes
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
14
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: USMC-6-120kW to 240kW – Scroll Option USMC-6-120 120
USMC-6-150 150
USMC-6-190 190
USMC-6-240
7 12
7 12
7 12
7 12
3000
3000
3000
3000
2025 2225
2025 2230
2025 2230
2025 2230
Cas 34 Painted
Cas 34 Painted
Cas 34 Painted
Cas 34 Painted
120
150
190
240
Condenser Design
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Unit Operation
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Compressor Style
Semi-Hermetic Scroll
Semi-Hermetic Scroll
Semi-Hermetic Scroll
Semi-Hermetic Scroll
4 Step 100 / 75 / 50 / 25
4 Step 100 / 75 / 50 / 25
4 Step 100 / 75 / 50 / 25
4 Step 100 / 75 / 50 / 25
R407C 26 Axial 75.2
R407C 32 Axial 76.5
R407C 34 Axial 76.6
R407C 48 Axial 76.6
400V 50Hz 3Ph 83 104
400V 50Hz 3Ph 107 133
400V 50Hz 3Ph 128 160
400V 50Hz 3Ph 158 197
570 Yes
788 Yes
910 Yes
1084 Yes
Micro Processor
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
No 5.7
No 7.2
No 9.1
No 11.5
Not included No No 100
Not included No No 100
Not included No No 100
Not included No No 100
100 No No
100 No No
100 No No
100 No No
Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW)
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Required Rated Pump Head Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
240
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
15
CHILLER CATALOGUE Chiller Range: USMC-6-220kW to 300kW – Screw Option Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW)
USMC-6-220 220
USMC-6-250 250
USMC-6-300 300
7 12
7 12
7 12
3250
3250 2400 2225
3250 2400 2225
2400 2225
Cas 31 Painted
Cas 31
Cas 31
Painted
Painted
220
250
300
Condenser Design
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Unit Operation
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Compressor Style
Screw
Screw
Screw
2 Step 100 / 75 / 50 / 25
2 Step 100 / 75 / 50 / 25
2 Step 100 / 75 / 50 / 25
R407C 40 Axial 75.2
R407C 46 Axial 76.5
R407C 50 Axial 76.6
400V 50Hz 3Ph 135 185.4
400V 50Hz 3Ph
400V 50Hz 3Ph
153 205.4
166 273.4
626 Yes
766 Yes
580 Yes
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
No 7.56
No 9.16
No 11.15
Not included No No 100
Not included No No 100
Not included No No 100
100 No No
100 No No
100 No No
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Rated Pump Head Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
16
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Chiller Range: USMC-6-360kW to 450kW – Screw Option Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW)
USMC-6-360 360
USMC-6-400 400
USMC-6-450 450
7 12
7 12
7 12
4800
4800
4800
3250 2225
3250 2225
3250 2225
Cas 31 Painted
Cas 31 Painted
Cas 31 Painted
360
400
450
Condenser Design
Air Cooled Aluminium
Air Cooled Aluminium
Air Cooled Aluminium
Evaporator Design Unit Operation
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Shell and Tube Cooling Only
Compressor Style
Screw
Screw
Screw
1 Step 100 / 75 / 50 / 25
1 Step 100 / 75 / 50 / 25
2 Step 100 / 75 / 50 / 25
R407C 50 Axial 75.2
R407C 55 Axial 76.5
R407C 60 Axial 76.6
400V 50Hz 3Ph 202 295.4
400V 50Hz 3Ph 219 325.4
400V 50Hz 3Ph 270 409.4
493 Yes
583 Yes
676 Yes
Micro Processor
Micro Processor
Micro Processor
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
Yes Yes Gen Fault / Remote Start & Stop 4
No 17.2
No 19.1
No 21.5
Not included No No 100
Not included No No 100
Not included No No 100
100 No No
100 No No
100 No No
Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Required Rated Pump Head Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass Include Flow Switch
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
17
CHILLER CATALOGUE Chiller Range: USMC-6-500kW to 900kW – Screw Option Key Features (Model) kW Size Water Supply Temp (◦C) Water Return Temp (◦C) Cabinet Length (mm) Depth (mm) Height (mm) Shipping Weight (kg) Operating Weight (kg) Cabinet Code Cabinet Finish Refrigeration Capacity (KW) Condenser Design Evaporator Design Unit Operation Compressor Style Number Compressors Comp Capacity Control Gas Type Gas Charge (kg) Fan Type Noise Level (dB(A)) Electrical Power Supply (V/PH/Hz) RLA FLA LRA Auto Program Controller Controller Type Comp Time Delay Auto Restart External Controls Control Stages Water Pump In-built Water Flow (l/s) Required Rated Pump Head Water Tank Prevention from freezing Pipe Size mm (supply) Pipe Size mm (return) Internal Bypass
USMC-6-500 500 7
USMC-6-600 600 7
USMC-6-720 720 7
USMC-6-800 800 7
USMC-6-900 900 7
12
12
12
12
12
4800 3250 2225
4800 3250 2225
4800 3250 2225
4800 3250 2225
4800 3250 2225
2 x Cas 31
2 x Cas 31
2 x Cas 31
2 x Cas 31
2 x Cas 31
Painted
Painted
Painted
Painted
Painted
500 Air Cooled Aluminium
600 Air Cooled Aluminium
720 Air Cooled Aluminium
800 Air Cooled Aluminium
900 Air Cooled Aluminium
Shell & Tube Cooling Only SemiHermetic Screw 4 Step 100 / 75 / 50 / 25 R407C 92 Axial
Shell & Tube Cooling Only SemiHermetic Screw 4 Step 100 / 75 / 50 / 25 R407C 100 Axial
Shell & Tube Cooling Only SemiHermetic Screw 2 Step 100 / 75 / 50 / 25 R407C 100 Axial
Shell & Tube Cooling Only SemiHermetic Screw 2 Step 100 / 75 / 50 / 25 R407C 110 Axial
Shell & Tube Cooling Only SemiHermetic Screw 4 Step 100 / 75 / 50 / 25 R407C 120 Axial
76.5
76.6
75.2
76.5
76.6
400V 50Hz 3Ph 306 411
400V 50Hz 3Ph 332 548
400V 50Hz 3Ph 404 591
400V 50Hz 3Ph 438 651
400V 50Hz 3Ph 540 820
1532 Yes Mcr Prcssr
1160 Yes Mcr Prcssr
946 Yes Mcr Prcssr
1166 Yes Mcr Prcssr
1352 Yes Mcr Prcssr
Yes
Yes
Yes
Yes
Yes
Yes Gen Fault / Remote Start & Stop 4
Yes Gen Fault / Remote Start & Stop 4
Yes Gen Fault / Remote Start & Stop 4
Yes Gen Fault / Remote Start & Stop 4
Yes Gen Fault / Remote Start & Stop 4
No 23.9 Not included
No 28.7 Not included
No 34.4 Not included
No 38.2 Not included
No 43 Not included
No No 2 x 100 2 x 100
No No 2 x 100 2 x 100
No No 2 x 100 2 x 100
No No 2 x 100 2 x 100
No No 2 x 100 2 x 100
No
No
No
No
No
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
18
Summit Matsu Chillers U4, 119-133 McEvoy Street , Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
CHILLER CATALOGUE Notes:
In the pursuit of continuous product improvement these specifications may change without notice This version current at 04 Feb 2013
Summit Matsu Chillers U4, 119-133 McEvoy Street Alexandria, NSW, 2015, Australia Tel: 1300 CHILLERS (1300 244 553) Tel: +61 2 9698 4666 Fax: +61 2 9698 4688 Email: info@matsu.com.au Web: www.matsu.com.au
19