Comat Control Components The comprehensive offer for the control technology
General Catalogue
Company
Since 1970 Comat AG has been the competent supplier of equipment and systems for industrial automation. In 1996 the company introduced a Quality Management System certified in accordance with ISO norm 9001. As a successful manufacturer in the industrial electronics field, Comat enjoys an outstanding world-wide reputation with its first-class range of industrial-, time delay- and monitoring relays. A variety of international patents underline the high degree of innovation. The subsidiary companies in Spain, Releco S.A. and in China, Comat (Tianjin) Industrial Electronic Co., Ltd. are members of the Comat group. All our own products are continually being re-designed and kept up to date in accordance with the latest state-of–the-art technology. As always, Comat manufactures all its own products at its headquarters in Worb, Switzerland. The in-house development department enables us to react swiftly and flexibly to changing customer requirements. In addition, customer-specific developments can also be realized in the usual business sectors. Starting from its position as the Swiss home market leader, Comat exports its products to 43 agencies in the most industrial countries, supported by a competent in-house team of product specialists. Comat is therefore able at any time to provide its customers comprehensive, technical advice and can actively provide support for problem solutions. In addition, Comat has established itself in the Swiss market as the general agent for well-known international manufacturers. Most of these suppliers are market leaders in their product segments. With its own calibrating laboratory for pressure and electrical parameters, accredited in accordance with EN ICO/IEC 17025, Comat also provides a calibration service of the utmost accuracy. Comat AG has devoted itself to unconditional customer satisfaction and subordinates all business activities to this end. The company’s philosophy proves this clear business policy, both externally as well as internally.
Index
Page 3
Industrial Relays / Miniature Contactor
Page 5
1
Page 51
2
Installations Relays / Staircase Lighting Timers
Page 103
3
Monitoring Relays
Page 111
4
SMS Relay / Miniature Controller Comat BoxX
Page 133
5
Time Delay Relays / Time Cubes / Time Modules
Comat, since over 35 years a strong name in the field of industrial electronics. COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
1
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
2
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Index
Industrial Relays Typ C2 C3 C4 C5 C7 C9 C10 C12 C14 C21 C22 C31 C32 C33 C34 C35 C36 C37 C38 C39 C103.01 C103.06 C133.01 C203.01 C203.04 C203.06 C301.04 C301.08 C311.08 CHA1 CINT-11 CINT-12 CINT-15 CINT-18 CINT-21 CINT-22 CINT-25 CINT-28 CINT-51 CINT-52 CINT-53 CINT-61 CINT-62 CINT-63 CPF11 CPF22 CR11C CR16AX CR16CX CR23A CR31 CR33A CRS1C CT2 CT3 CTV11 KA108 KA115 KA208 KD125 KD215
Page 22 23 24 25 16 18 13 14 13 28 28 29 29 30 30 40 40 40 40 30 37 37 37 37 37 37 37 45 45 12 10 10 10 10 10 10 10 10 11 11 11 11 11 11 46 46 36 36 36 36 17 36 36 32 32 45 41 41 41 42 42
Time Delay Relays Typ KD315 KDM3-24 KDW3-24 KR13 KR23 KR33 RC1 RCL1 RD1 RD2 RD3 RDL1 RDL2 RDL3 RIC20 RIC25 RIC40 RIC63 RIC-AUX RL1 SOC-2 SOC-6 SS-1BM SS-1HM SU-404M SU-422M SU-440M
Page 42 43 44 19 19 19 33 33 33 33 33 33 33 33 50 50 50 50 50 33 49 48 48 48 48 48 48
Typ AA2 AA2M AE2 AE2M AM1 AM2 AM3 C52 C53 C53.3 C53.4 C55 C55.3 C55.4 C56 C63 C64 C65 C66 C81 C82 C83 C84 C85 CCX-350 CCX-550 CEA-126 CEA-226 CFG-126 CIM1 CM1 CM1L CM2 CM3 CN135 CNR1 CNS-4 CPF11 CPF22 CPX-129 CPX-519 CRA1 CRE1 CRT3 CRV1 CRV2 CRV3 CS1 CS2 CS3 CSV2 CT1 CT1L CT2 CT3 CT30 CT32 CT33 CT36 CTI-129 CTI-519
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Page 82 82 82 82 84 84 84 70 70 71 71 70 71 71 70 68 69 69 69 67 67 67 67 67 95 95 79 77 79 84 85 85 85 85 90 86 90 94 94 78 77 82 82 83 83 83 83 68 68 68 83 86 86 61 61 63 63 63 63 78 77
Monitoring Relays Typ CU23 CWR-102 CX 38 CX 39 CY1 ECO31 ECO32 RS 41-M RS 121 RS 121.P RS 121.R RS 122-H RS 122-M RS 122-MH RS 321 RS 521 SBV11 SSV11 SFR1 SFR2
Page 91 79 80 80 82 87 87 76 74 74 74 75 75 75 76 76 93 93 92 92
Typ CT512 CT515 CT516 CT524 CUEBI CUEBU ECR-3D EOCR-AR ESU-D2 EUCR-BR MV52 MV53 MV62 SRCT-35 SSU11 SSU12 SSU13 SSU14 SSU16 SSU22 SSU23 SSU24 SSU25 SSU26 SSU29 SSU31 SSU33 SSU34 SSU36 SSU72 SSU73 SSU74 SSU75 SSU76 SSU79 TSR19
Page 123 123 123 116 124 117 121 120 130 120 114 115 114 122 118 118 118 118 118 118 118 118 118 118 118 128 126 127 127 118 118 118 118 118 118 132
Installation Relays Type A333 AL1 AL2 AL3 AL4 AL4C AL5 B103 CIM1 CRS1C RIC20 RIC25 RIC40 RIC63 RIC-AUX
Page 107 108 108 108 109 109 109 107 106 106 110 110 110 110 110
SMS Relay CMS-10
135
Comat BoxX AF-10 AF-20
139 139
Socket 11PGL C11A C12B C12B0 C12B1 CS8 CS11 CS18 EC8 EC11
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
98 98 98 98 98 98 98 98 98 98
3
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
4
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
1
• Interface Relays • Miniature Relays • Standard Relays • Long Life Relays • Time Cubes and Relay-Modules • DIN Relays • Solid-State Relays • Miniature Contactors
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
5
KAT 2008
Pa ge
Co nta c
So ck
Se rie s
Relays Overview
et
t
Industrial relays
Interface Relays Interface Module ultra slim
CINT 11/ 12 DIN 35
6A
10
Interface Module ultra slim
CINT15 / 18 DIN 35
2A
10
DIN 35
10 A
11
CINT 52 / 53 DIN 35
8A
11
10 A
12
C14 /C10
10 A
13
C12
5A
14
Miniature Industrial Relays 2-pole
C7
10 A
16
Miniature Industrial Relays 3-pole
CR 31
10 A
17
Miniature Industrial Relays 4-pole
C9
5A
18
Miniature Signal Relays 2-pole
KR13
3A
19
Miniature Signal Relays 2-channel
KR 23
2x 3A
19
Miniature Signal Relays 3-channel
KR 33
3x 3A
19
Interface Module 2-pole Interface Module 2-pole Relays for switching of PLC I/O´S
AUTO-ON-OFF-Relays Interface Relays plug-in Interface Relays plug-in 2-pole
CINT 51
CHA1
DIN 35
Miniatur Industrial Relays
The space saving alternative makes the best use of the control panel. In various executions: • Power Relay 10A • Control Relay with twin contacts 6 A • Signal relay with gold contacts
Standard Industrial Relays
The well proven Industrial Relay according IEC 67.1 as: • Power Relay 10A • Control Relay with twin contacts 6A • Signal relay with gold contacts • Remanence Relay
Standard Industrial Relays 2-pole
C2
10 A
22
Standard Industrial Relays 3-pole
C3
10 A
23
Standard Industrial Relays 4-pole
C4
10 A
24
High Power Relay 3-pole
C5
16 A
25
LONG LIFE Industrial Relays 2-pole
C21
10 A
28
LONG LIFE Industrial Relays 2-pole
C 22
6A
28
LONG LIFE Industrial Relays 3-pole
C 31
10 A
29
LONG LIFE Industrial Relays 3-pole
C 32
6A
29
LONG LIFE Power Relays 2-channel
C 33
2x 10 A
30
LONG LIFE Signal Relays 2-channel
C34
2x 5 A
30
LONG LIFE Signal Relays 3-channel
C 39
3x 5 A
30
LONG LIFE Industrial Relays
The well proven Industrial Relay according IEC 67.1 for: • ≥ 100 Mio. mechanical switching cycles • ≥ 700000 switching cycles under max. load as: • Power Relays 10A • Signal Relay with twin contacts 6 A
Time Cubes and Relays Modules
6
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
Plug-in Time Cubes
CT2 / CT3
32
Plug-in Coil Wirings
R-Module
33
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
DIN-Relais CR16
DIN 35
6A
36
Control Relays 2-channel
CR 23 A
DIN 35
2x 3A
36
Control Relays 3-channel
CR 33 A
DIN 35
3x 3 A
36
Signal Relays 2-pole
CR 11C
DIN 35
1A
36
Step-on Step-off Relays
CRS1C
DIN 35
6A
36
Power Relays 1-pole
C103
DIN 35
6A
37
Power Relays 2-pole
C133
DIN 35
6A
37
Control-/Signal Relays 2-channel
C 203
DIN 35
2x 5 A
37
Control Relays 3-channel
C 301
DIN 35
3x 5 A
37
Universal Solide State Relays 1-channel
C 35
UC 0,8 A
40
AC Solide State Relays 2-channel
C 36
2x 0,8 A
40
DC Solide State Relays 1-channel
C 37
5A
40
DC Solide State Relays 2-channel
C 38
2x 2A
40
Power Relays 1-pole
Direct snap on Industrial Relays: • Power Relay • Contol Relay with twin contacts • Signal Relay with gold contact • Step-on/ Step-off Relay
Solide State Relays
The alternative for highest switching frequency and non-wearing switching. • Triac outputs for AC and DC loads, short circuit resistent. • Transistor outputs for DC loads, short circuit resistent.
Universal AC Solide State Relays 1-channel
KA108
Triac 0,8 A
41
Universal AC Solide State Relays 1-channel
KA115
Triac 1,5A
41
Universal AC Solide State Relays 2-channel
KA 208
Triac 2x 0,8 A
41
Universal DCSolide State Relays 1-channel
KD125
2,5 A
42
Universal DC Solide State Relays 2-channel
KD 215
2x 1,5 A
42
Universal DC Solide State Relays 3-channel
KD 315
3x 1,5 A
42
DC Motor Control Relays with brake function
KDM 3-24
DIN 35
3A
43
UC Solide State Changeover Relays
KDW 3-24
DIN 35
3A
44
CTV11
DIN 35
250 mA
45
C301/C 311 DIN 35
3x 2 A
45
Switching Amplifier 1-channel Switching Amplifier 3-channel Pulse Shaper
CPF 11
DIN 35
2A
46
Pulse Shaper
CPF 22
DIN 35
2x 150 mA
46
Universal Miniature Contactors
SOC-6
DIN 35
20 A
48
Universal Miniature Contactors
SOC-2
DIN 35
20 A
49
Installation Contactors
RIC 20
DIN 35
20 A
50
Installation Contactors
RIC 25
DIN 35
25 A
50
Installation Contactors
RIC 40
DIN 35
40 A
50
Installation Contactors
RIC 63
DIN 35
63 A
50
Miniature Contactors
With 3 main contacts 20...63A and auxilliary twin signal contacts 10A. Contact openings >3 mm, test voltage 4000V. Specially suitable for save breaking in low voltage circuits.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
7
KAT 2008
Industrial Relays
Pa ge
Co nta c
So ck
Se rie s
Outline Overview
et
t
Industrial relays
1
General information Contacts There are several different types of contact materials for relays. The main distinction can be made between single contacts and twin contacts. While single contacts are more suitable for higher loads, twin contacts are significantly more reliable for low switching loads, i.e. < 24 V, < 100mA. Contact material There is no all-purpose universal contact. AgNi is used as a standard contact material for a wide range of applications. For applications in aggressive atmospheres, AgNi contacts with hard gold plating (up to 10 µm) are recommended. There is however no other purpose then corrosion protection during storage. Relays with tungsten pre-contacts are available for very high switching currents (up to 500A, 2.5 ms. Minimum load The minimum load values are recommended values under normal working conditions i.e. regular switching, no special ambient conditions, etc. Under these conditions reliable switching can be expected. Contact resistance In practice the contact resistance may vary depending on the switching load and other environmental conditions. For higher currents the contact resistance is around 10mΩ. Contact spacing Normally all open contacts have an air gap between 0,5 .. .1.5mm. They are referred to as µ contacts according to the Low-Voltage Directives and associated standards. These contacts are not suitable for safe disconnection. For switching of DC loads, large contact clearances are requested for the quenching of the electric arcs. (Pls.refer to special relays: Series connections.) Switching capacity The contact switching capacity is the product of switching voltage and switching current. For AC, the permitted switching capacity is generally enough to handle the max. continuous AC1 current over the whole voltage range. It is not allowed to exceed the load limit curve for DC switching because a remaining switch-off-arc would destroy the relay immediately. The DC switching capacity is 100W (DC 1). Drive (coil) A distinction is made between standardised voltages according to EN 60947 as guaranteed values, and typical values which can be expected with a high degree of probability. Pick-up voltage, Release voltage The pick-up voltage is the voltage at which the relay engages safely. The typical trip voltage for DC is approx. 65% of Unom and approx. 75% of Unom for AC. The release voltage is approx. 25 %, resp. 60% of Unom. For DC, these voltages depend strongly on the temperature coefficient for Cu. This is however not the case for AC, where the constant inductive resistance over a wide temperature range is the controlling factor. Under voltages in AC relays results in humming and armature fluttering and should therefore be avoided. Operating voltage range The upper voltage limit of the coil is determined by the heat and the ambient temperature. The self-heating trough the contacts under high loads should not be underestimated since it may even be higher than the dissipated energy of the coil. Significantly high but short period overvoltage however provides no problem for intermittent operations. In doubt please consult our specialist or ask for the respective characteristic curve diagram. Coil connections Different coil connections can be integrated into the relay as an option. A costeffective freewheeling diode is available for DC coils. Please note that the stated release times are generally specified without the coil connection. While an additional LED status indicator has practically no effect, a freewheeling diode (D) will lead to an increase in release time by a factor 2 to 5, or 0 ms to 30 ms. For AC coils, VDRs or RC elements may be used. In this case resonance effects may have to be considered. VDRs and common RC elements may increase release times by < 5 ms.
8
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
General design Comat (Releco) relays are made from carefully selected high-quality materials. The components comply with the latest environmental regulations such as RohS. The meticulous design makes the relays particularly suitable for any industrial application and engineering installation. The robust terminals, mechanical position indicator, dynamic and permanent hand activators, all integrated in the standard relay make them particularly service friendly. Colour coded hand test buttons dependent on the type of coil voltage is another useful feature. Options - Different coil connections - Freewheeling diodes - LED displays - Bridge rectifiers for AC/DC drives, etc. Additionally, because of short-term availability of special versions for practically any drive voltage up to DC 220V / AC 400 V the relays are a cost effective solution for many applications For safety reasons, manual operated test buttons may be replaced with a blank button, if required. Further information To select the most suitable relay and to guarantee a reliable operation and a long service life for the application, several factors need to be considered. In particular these are: -Number of cycles -Switching frequency -Ambient conditions -Load type -Switch-on current and load switch-off energy. Example If the number of cycles are expected to exceed > 100,000 operations per year. (E.g. clock generators, fast running machines), an electronic solution is perhaps more appropriate. Comat is able to offer a suitable relay from our standard product range. In AC applications, crosstalk caused by long control leads is often a problem and can result in constant humming of the relay or even inadvertent triggering due to interference. Here too, we offer solutions. Various, apparently harmless loads may lead to very high switch-on currents or switch-off energy values This may result in an unacceptable reduction of the service life. Inductive DC loads are especially harmful. Characteristics of various loads: Heating circuits No high switch-on currents, no high switch-off loads. Incandescent lamps, halogen lamps Switch-on currents during a few ms in the range 10 x rated IN. Switch-off at rated load. Low-energy lamps Very high, with very short switch-on currents due to built-in decoupling capacitors. Contacts have a tendency to fuse. Transformers, AC contactors Switching on during zero-transition may avoid high inrush currents. If switching before or after the zero crossing, switch-on currents of 8. . .15 x rated IN.may occur. High inductive switch-off energy is possible. The load must be wired, due to EMC problems.
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Interface Relays
1
Interface Relays Recommended application 100A peak
10 A 8A 6A 5A 2A
100A peak
1 2
C14-A10 C10-A14 CINT51 CINT61
CINT11 CINT21 CINT52 CINT62
CINT53 CINT63
C10-T13
C10-T12
CINT12 CINT22
CINT18 CINT28
&
Solid-State
Triac
300 mA 50 mA 10 mA 5 mA 1mA
CINT15 CINT25
C12-A21 C12-A22
1+1
CHA1 twin contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
9
KAT 2008
Interface modules
Interface-Solide-State Modules AC 230VA
CINT1 CINT2
DIN
Interface
12
LABEL
LABEL
Relay module CINT-R1/ CINT-R2
MADE IN EC
A1
V
V
A1
A1
A2
A2
With cage clamp terminals (1x 0,2 - 2,5 mm 2) CINT-21, -22, -25, -28
CINT-11, CINT-21
3600V
Tamb. operation/storage: -20..+55/ - 40..+85°C
and others:
www.comat.ch
MAX MIN
11 12
SOCKET
6,2
Interface Module Complete with integrated LED and switching module.
14
A2
6-24
6-24
With srcew terminals (0,2 - 2,5 mm 2) CINT-11, -12, -15, -18
Test voltage:
Solid-State module CINT-R5 / CINT-R8
(+)
MODULE
MODULE
SOCKET A2
RELAY
RELAY
NC
12 CINT1/ UC6-24VU
14
Max. 6A 250V (see module)
COMAT SOCKET
11
14
12
11
COM
11
RELAY
A2(–)
COIL
A1(+)
A1
RELAY
01
CINT12/UC24V
11
(+)
14
NO
OUT
14
01
CINT-R2/ UC24VU
AVING SPACE S
12
CINT-12, CINT-22
CINT-15, CINT-25
CINT-18, CINT-28
Interface Module
Interface Module
Interface Module
Interface Module
for PLC’s and process control. High power contact AgSnO2. With screw terminals (CINT-11) or cage clamp terminals (CINT-21).
for PLC’s and process control. Signal contact AgNi +5µ Au. With screw terminals (CINT-12) or cage clamp terminals (CINT-22).
for PLC`s and process control. DC solid-state switch NO, pnp. Integrated transient clamp circuit. For fast and high frequency switching. With screw terminals (CINT-15) or cage clamp terminals (CINT-25).
for PLC`s and process control. AC solid-state switch type NO synchronous switching triac. For fast and high frequency switching. With screw terminals (CINT-18) or cage clamp terminals (CINT-28).
6 A 250 V A
6 A 250 V A
2 A 24 V D
2 A 250 V A
10mA 12V
1mA 1V
1mA 6V
10mA 12V
Data at Tamb. =20°C (standard coil)
Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance/voltage drop
AgSnO 2 1500VA ...250W 300VA/230V 100A/2,5ms 10x106 /105 <100m
Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay/release time Parallel circuit
0,7...1,25Un 0,8...1,2UN 0,8...1,2UN 240mW 240mW 240mW 1,1W – 1,1W 5ms/10ms <1ms 5ms/10ms All modules have an internal parallel diode circuit; green LED status indication.
AgNi + 5µ Au 1500VA ...250W – 10A/20ms 10x106 /105 <100m
24, 230 CINT-12/UC.....V CINT-22/UC.....V
DC ≤ 10% CINT-R1/UC110-240V CINT-R1/UC24V
CINT-R2/UC110-240V CINT-R2/UC24V
Connector bridge CINT-BR20
12
KAT 2008
TS 35
With srcew terminals
A1
A1
A2
A2
6,2
With cage clamp terminals
44,3
41,5
(packing unit: 2x 10pin)
10
Marking label (supplied with standard delivery) CINT-BEZ
12 11
Connector bridge CINT-BR20
(packing unit: 64 pieces)
CINT-R8/DC24V
14
Accessories/Sparte parts
Marking label CINT-BEZ
CINT-R5/DC24V
11
47.0
Module d’interface CINT-21/UC24V
CINT-18/DC24V CINT-28/DC24V
14
88,5
Ordering example
CINT-15/DC24V CINT-25/DC24V
93,5
Replacement Switching modules
0,7...1,25Un 240mW – <1ms
TS 35
50/60 Hz /
Solid-state (Triac) 500VA – – 20A/10ms – <1,5V
49,2
24, 230 CINT-11/UC.....V CINT-21/UC.....V
UC
Solid-state – ...60W – 20A/10ms – <100m /200mV
3,4
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
73
6,2
3,4
73
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Interface Modules CINT5 CINT6
Industrial Relays
DIN
Interface RELAY
Relay module CINT-51/61 RELAY
CINT-52/62 CINT-53/63 A1
12 11 14
22 21 24
A2 SOCKET
With srcew terminals (0,5 -2,5 mm 2) CINT-51, -52, -53
With cage clamp terminals (1x 0,5 -2,5 mm 2) CINT-61, -62, -63
CINT-51, CINT-61 Interface Module Complete with integrated LED and relay.ul. Test voltage:
3600V
Isolation / // / : 4000Vrms // 2000Vrms Tamb. operation/storage:
-20..+55/ - 40..+85°C and others:
www.comat.ch
MAX MIN
CINT-52, CINT-62
CINT- 53, CINT- 63
Interface Module
Interface Module
Interface Module
for PLC’s and process control. 1 x CO high power contact AgSnO2. With screw terminals (CINT-51) or cage clamp terminals (CINT-61). With LED output status display.
for PLC’s and process control. 1x CO signal contact AgNi+5µ Au. With screw terminals (CINT-52) or cage clamp terminals (CINT-62). With LED output status display.
for PLC`s and process control. 1x CO signal contact AgNi for standard applications. With screw terminals (CINT-53) or cage clamp terminals (CINT-63). With LED output status display.
10 A (13 A) 250 V A
8 A 250 V A
8 A 250 V A
50mA 24V
1mA 12V
10mA 24V
Data at Tamb. =20°C (standard coil)
Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance
AgSnO 2 2500VA ...300W 300VA /230V 100A /5ms 10x106 /105 <100m
Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay/release time Parallel circuit
0,8...1,2UN 0,8...1,2UN 0,8...1,2UN 480mW 480mW 480mW 1,1W 1,1W 1,1W 5ms /10ms 5ms/10ms 5ms/10ms All modules have an internal parallel diode circuit; green LED status indication.
Replacement relay modules
24, 230 CINT-51/ UC.....V CINT-61/ UC.....V
24, 230 CINT-52 / UC.....V CINT-62 / UC.....V
24, 230 CINT-53 / UC.....V CINT-63 / UC.....V
CINT-R21/UC110-240V CINT-R21/UC24V
CINT-R22/UC110-240V CINT-R22/UC24V
CINT-R23/UC110-240V CINT-R23/UC24V
Connector bridge CINT-BR8
22 NC 12
Ordering example
Marking label (supplied with standard delivery) CINT5-BEZ
22 NC 12 21 COM 11
21 COM 11
Connector bridge CINT-BR8/5 (packing unit: 1x 5 pieces)
Marking label CINT5-BEZ /18 (packing unit: 1x 18pieces)
RELAYS
93
48,5 91
TS 35
With cage clamp terminals
With srcew terminals 220-240 VU
220-240 VU
42,5
Accessories/Spare parts
RELAYS
Interface module CINT-51/UC24V
48
24 NO 14
24 NO 14
TS 35
50/60 Hz /
Ag Ni 2000VA ...250W – 15A/20ms 10x106 /105 <100m
A1
A1
A2
A2
14
3,4
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
72
14
45
UC
AgNi + 5µ Au 2000VA ...250W – 15A /20ms 10x106 /105 <100m
3,4
72
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
11
KAT 2008
1
AUTO - ON - OFF Relay CHA1 Interface
DIN
UR PLC FOR YO A1 A2
B1 B2
24V AC/DC 24 V 300 mA
B1 CHA1 / UC 24 V U
24V AC/DC B1
A1(+)
B2
A2(–)
ON OFF AUTO
A2(–)
S
ON
24V 300mA
ON OFF AUTO
AUT
OFF
S
A1(+)
B2
01
A3
11
14
12
10A 250V
MADE IN EC-01
10A 250 VA
ON 01
A3
11
12
14
10A 250V
11 A3
12 14
CHA1 Interface Module
Interface Module
Complet with hand switch and LED for AUTO position indication.
for control systems with 1x CO high power contact, 1x NO signal contact 300mA. Installation: 45mm front dimension. Front setting: AUTO-ON-OFF for maintenance and emergency operation
Test voltage: 3000V Tamb. operation/storage: -10..+50/ - 40..+85°C
and others:
www.comat.ch
MAX MIN
Data at Tamb. =20°C (standard coil)
10 A 250 V A 10mA 12V Power contact
Signal contact
Contact material Switching current/voltage Switching power AC1 Switching power AC15 Switching power DC1 Peak inrush current Mechanical switching cycles Contact resistance
AgCdO 10A 250V 2500VA 500VA/230V ...250W 100A 2,5ms 10x106 <100m
Ag 300mA /30V 10VA 10W 0,5A 103 <100m
Operation voltage AC50/60Hz Operation voltage DC Power consumption Pmax
0,8..1,2UN 1,1UN (10A) 400mW/24V
–– –– ––
UC 50/60 Hz /
CHA1/UC24V
Marking label (supplied with standard delivery) CHA-BEZ/10
A1 A2
62
45
TS35
84
B1 B2
Ordering example Interface module CHA1/UC24V
11 A3
12 14
Marking label CINT5-BEZ /18
26,5
(packing unit: 1x 18pieces)
12
KAT 2008
11,5
4
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
17 58
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Power Relay
C14 /C10 Interface
C14: 31 C10: 35,5
WH: 12,5 x 29
AC230V
AC230V
RELAY
• Extremley rigid terminal pins (Faston 4,8mm) Test voltage: 5000V Tamb. operation/storage: -20..+60/ - 20..+100°C
MAX MIN
and otheres:
www.comat.ch Connection No. on socket ➞
Designation according to DIN/EN 50011 ➞
3 Au
10 Au
UC24V
RELAY
RELAY
C10 - A10
C10 - T13
Universal Power Relay 10 A
Universal Power Relay 10 A
Relay like .. A10, but with twin contacts 6 A
for AC- and DC-circuits ranging from 10mA 10V. Without manual activation button and mechanical status display.
for AC- and DC-circuits ranging from 10mA 10V. With lockable manual activation button and mechanical status display.
the control relay with highest switching reliability for control circuits ranging from 5mA 5V. With lockable manual activation button and mechanical status display.
1
C10 - T12 Relay like ..T13, but with 10 gold plated twin change over contacts for highest switching reliability. Suitable for signal circuits ranging from 1mA 5V. Recommended for applications up to 0,2A 30V. With lockable manual activation button and mechanical status display.
10 A 250 V A
10 A 250 V A
6 A 250 V A
6 A 250 V A
10mA 10V
10mA 10V
5mA 5V
1mA 5V
3 2 1 12 11 14
3 2 1 12 11 14
3 2 1 12 11 14
3 2 1 12 11 14
z
z
z
z
Connection with interface socket CS-106
+
z = contact opening < 3mm
Signal Relay
DC24V
RELAY
C14 - A10 1-pole Miniature Industrial Relay
Control Relay
Industrial Relays
Power Relay
A2 5
+
A1 4
A2 5
+
A1 4
A2 5
+
A1 4
A2 5
A1 4
Data at Tamb. =20°C (standard coil)
Contact material Switching load AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1)
AgNi 2500VA/...300W//10A 30VD 30A(20ms) 20 x106/≥105
AgNi 2500VA/...300W//10A 30VD 30A(20ms) 20x106/≥105
AgNi+3 Au 1500VA/...150W//5A 30VD 15A(20ms) 20x106/≥105
AgNi+10 Au 1500VA/...150W 15A(20ms) 20x106/≥105
Operation voltage AC 50 Hz / DC Power consumption AC / DC Triggering delay / release time
0,8...1,2UN 1,1VA/700mW 11/8ms
0,8...1,2UN 1,1VA/700mW 11/8ms
0,8...1,2UN 1,1VA/700mW 11/8ms
0,8...1,2UN 1,1VA/700mW 11/8ms
Standard
Standard
Standard
FX X BX
AC 50/60Hz
C14-A10
24, 115, 230 / AC ..... V
AC C10-A10X
50/60Hz
DC ≤ 20%
C14-A10
115, 230 / AC ..... V
115, 230 / AC ..... V
C10-T13X
C10-T12X
24, 48,110 / DC ..... V
≤ 20%
12, 24, 48,110 C10-A10X / DC ..... V
12, 24, 48,110 C10-T13X / DC ..... V
12, 24, 48,110 C10-T12X / DC ..... V
≤ 20% ≤ 20%
12, 110 C10-A10FX / DC ..... V
12, 110 C10-T13FX / DC ..... V
12, 110 C10-T12FX / DC ..... V
24, 48 C10-A10BX / UC ..... V
24, 48 C10-T13BX / UC ..... V
24, 48 C10-T12BX / UC ..... V
DC DC DC UC 50-400 Hz /
Interface socket CS-106
Interface socket CS-116
S10-B
75
Busbar S10-B
12 11 14
12 11 14
3
1
3
CS-116 6 4
5
2
2
(Option)
Option: Conductor bridge refer (next page)
1
Incl. Label: S10-RH
Term. 2 (11)
Ordering example Relay C10-A10X/DC24V Socket CS-106 (clip incl.) Connector S10-B
115, 230 / AC ..... V
75
Standard
Term. 5 (A2)
*) CS-106 standard delivery
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
S10-B
3
23
Incl. Clip S10-CG *)
35,5 / 31 (C15)
5
A2 A2 A1
17
Incl. Clip S10-CG
CS-116 6 4
A2 A2 A1
3
23
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
35,5 / 31 (C14)
13
KAT 2008
Control Relay
Signal Relay
C12 Interface
10 Au
WH: 12,5 x 29
AC230V
DC24V
RELAY
RELAY
C10: 35,5
C12-A 21 2-pole Miniature Industrial Relay
UniversalControl Relay 5 A
• Rigid terminal pins
MAX MIN
and otheres:
Signal Relay 5 A
With two change over contacts for AC- and DC- circuits ranging from 10mA 10V. With lockable manual activation button and mechanical status display.
Test voltage: 5000V 3000V Tamb. operation/storage: -20..+60/ - 20..+100°C
www.comat.ch
C12- A 22 With gold plated twin change over contacts for increased switching reliability. Suitable for AC- and DCcircuits ranging from 5mA 5V. With lockable manual activation button and mechanical status display.
5 A 250 V A
5 A 250 V A
10mA 10V
5mA 5V
Connection No. on socket ➞
9
Designation according to DIN/EN 50011 ➞
8
9
3 2 1 12 11 14
7
3 2 1 12 11 14
7
22 21 24
22 21 24
Connection with interface socket CS-112
8
z
z
+
+
z = contact opening < 3mm
A2 A2 5 6
A2 A2 5 6
A1 4
A1 4
Data at Tamb. =20°C (standard coil)
Contact material Switching load AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1)
AgNi + 0,3µ Au 1250VA/...150W// 5A 30VD 15A(20ms) 10x106/≥105
AgNi+10 Au 1250VA/...150W// 5A 30VD 15A(20ms) 10x106/≥105
Operation voltage AC 50 Hz / DC Power consumption AC/DC Triggering delay / release time
0,8...1,2UN 1,1VA/700mW 10/8ms
0,8...1,2UN 1,1VA/700mW 10/8ms
50/60Hz
C12-A21X
115, 230 / AC ..... V
115, 230 C12-A22X / AC ..... V
DC ≤ 20%
12, 24, 48, 110 C12-A21X / DC ..... V
12, 24, 48, 110 C12-A22X / DC ..... V
≤ 20% ≤ 20%
12, 110 C12-A21FX / DC ..... V
12, 110 C12-A22FX / DC ..... V
24, 48 C12-A21BX / UC ..... V
24, 48 C12-A22BX / UC ..... V
AC
Standard
Standard
DC DC
FX X
UC
BX
50-400 Hz /
Conductor bridge for interface socket CS-112 and CS-116
Interface socket CS-112
12 11 14
12 11 14
3 2 1 22 21 24
3 2 1 22 21 24
9
9
8
7
8
V10-R V10-B
7
V40-G V40-R V40-B
Ordering example Relay C12-A21X/DC24V Socket CS-112 (clip incl.) Conductor bridge V40-B
14
KAT 2008
Type: V10-G
75
Incl. Label: S10-RH
Option: Conductor bridge
5
CS-112 6 4
A2 A2 A1
5
Incl. Clip S10 - CG
CS-112 6 4
A2 A2 A1
17
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
3
23
35,5
A2 -A2
B20-G B20-R B20-B
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Miniature Relays
1
Miniature Relays Recommended application
A detailed list can be found on our web page:
www.comat.ch
500A peak
10 A 6A 5A 3A
Remanence
Comat products comply with different international standards and are certified accordingly.
&
10 mA 5 mA 1mA 100 µA 2
C7-A20
3
CR31
C7-W10
C7-T21
4
C7-T22
KR13
C9-A41
1+1
C9-R21
C9-A42
C7-H23
2x 1
KR23
3x 1
KR33 twin contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
15
KAT 2008
Power Relay C7 Miniature SEISMIC
Control Relay Signal Relay
High Power Relay
Power Relay Signal Relay
10 Au
0,2 Au
ED
APPROV
DC 24 V D
37,5
C7-T21
C7-A 20 2-pole Miniature Industrial Relay • lockable manual operation • mechanical flag indicator Test voltage:
AC 230V A
DC 24 V D
AC 230V A
WH: 21x 28
AC 230V A
2500V 2500V
Tamb. operation/storage: -20..+60/ - 40..+85°C
and others:
www.comat.ch
MAX MIN
C7-T22
Universal Power Relay 10 A
Relay like .. A20, but with twin contacts 6A
with 2 power changeovercontacts this is a robust relay for AC and DC circuits ranging from 10mA10V.
the control relay with highest switching reliability for control and signal circuits ranging from 5mA 5V.
10 A 250 V A 10mA 10V
Connection No. on socket ➞
Connection with socket CS-18
6 A 250 V A
6 A 250 V A
10 / 6 A 250 V A
10 A 250 V A
5mA 5V
1mA 5V
10mA 10V // 1mA 5V
10mA 10V
4 2 3 1 24 22 14 12
4
4 2 3 1 24 22 14 12 z
+ A2 21 8 6 4 6 2 24 22 21
3 5 1 14 12 11
z
+
11 A1 5 7
A2 21 8 6
3 5 1 14 12 11
z
A2 8
A1 7
11 A1 5 7
4 6 2 24 22 21
3 5 1 14 12 11
3 5 1 14 12 11
4
5
z
+ A2 8
A1 + 7
A2 8 5
z
+
A1 7
A2 21 8 6
z
+ A2 8
+
11 A1 5 7
4 6 2 24 22 21
with tungsten special early make contact. Specially suitable for filament and halogen lamps, transformers, etc. No mecanical flag indicator.
z
z
+
11 A1 5 7
4 6 2 24 22 21 Connection with socket CS-109
4 2 3 1 24 22 14 12
z
A2 21 8 6
Heavy duty Relay for 500 A inrush current
the twin contact relay with highest switching reliability for signal circuits ranging from 1mA 5V. Recommended upto 0,2A 30V.
z
= contact opening < 3mm
Power Relay 10 A with supplementary twin contact 6A (3zAu) for a secondary circuit switch, i.e. to ensure reliable signal of relay switch position to the central control, SPC, distribution system.
4 2 3 1 24 22 14 12
Designation according to DIN/EN 50011➞
C7-W10
C7- H23
Relay like .. T21, but 10 gold plated contacts
+
A1 7
A2 8
+
A1 7
A2 8
A1 7
Data at Tamb. =20°C (standard coil)
Contact material Switching power AC1 Switching power DC1 Peak inrush power Switch. cycles mech./electr. (AC1)
AgNi 2500VA ...250W 30A(20ms) 20x106/≥ 3x105
AgNi+0,2zAu 1200VA ...150W 15A(20ms) 20x106/≥ 2x105
AgNi+10zAu 1200VA ...150W 15A(20ms) 20x106/≥ 2x105
AgNi // AgNi+3zAu 2500VA // 1500VA ...250W // ...180W 30A // 15A(20ms) 20x106/≥ 2x105
W/Ag 2500VA ...250W 500A(2,5ms) 20x106/≥ 3x105
Operation voltage AC 50 Hz / DC Power consumption AC/DC Triggering delay / release time
0,8...1,2UN 1,5VA/1W 16/8ms
0,8...1,2UN 1,5VA/1W 16/8ms
0,8...1,2UN 1,5VA/1W 16/8ms
0,8...1,2UN 1,4VA/1,1W 15/8ms (30ms “DX”)
0,8...1,2UN 1,8VA/1,5W 20/10ms
24, 48, 115, 230 C7-A20 X / AC ..... V
C7-T21
24, 48, 115, 230 X / AC ..... V
24, 48, 115, 230 C7-T22 X / AC ..... V
≤ 10%
12, 24, 48, 110, 125 C7-A20 / DC ..... V
12, 24, 48, 110, 125 C7-T21 / DC ..... V
12, 24, 48, 110, 125 C7-T22 / DC ..... V
≤ 10%
12, 24, 48, 110, 125 C7-A20D X / DC ..... V
12, 24, 48, 110, 125 C7-T21D X / DC ..... V
12, 24, 48, 110, 125 C7-T22D X / DC ..... V
AC
Standard
50/60Hz
DC
Standard
DC
D, DX
= Type X (option)
Option X = with
2
3
1
24 22 14 12
Ordering example 3
6
Socket CS-18 Retaining clip RC-G (option) Socket CS-109 (clip incl.) A2-connector S7-B (option) Socket S7-P (page 5*) Retaining clip RC-G (option)
16
KAT 2008
8
5
CS-18
24 22 14 12
24 22 14 12
4 21
4 21
2
3 11 2
1
2
3 11
6
5
1
5
Clip RC-G
7
CS-109
CS-109
Plug-in R/C-unit RC0047-100/AC250V
21 11
8A2 6B1 5 7A1
22,5
12, 24, 48, 110, 125 C7-W10D X / DC ..... V
75
1
4
24 C7-H23DX / DC ..... V
75
2
12, 24, 48, 110, 125 C7-W10 / DC ..... V
Interface socket CS-109 (all connections on top)
6
Relay C7-A20X/AC230V Socket ...
24, 48, 115, 230 C7-W10 X / AC ..... V
Entire series of C7. Comply to IEE 323 and IEE 344 (seismic qualified)
System socket CS-18 (connections 5 and 6 on bottom) 4
230 / AC ..... V
C7-H23X
8
9
A2
3
22
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
37,5
22,5
7
8
A1
A2
9
S7-B 7
(A2)
A2-connector S7-B
A1
3
23
Clip S9-CG
37,5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Power Relay
NO COM
10A 250Va
AgNi
285396174
22 2124 32 3134121114 A2
MADE IN EU
+
10A 250Va
AgNi
285396174
A1
Industrial Relays
NC
01
MADE IN EU
CR31D/DC24V D
01
CR31/AC230V A
CR31 Miniature
22 2124 32 3134121114 A2
A1
1
CR31 3-pole Miniature Industrial Relay
Universal Power Relay 10 A The CR31 is a 3-pole miniature industrial relay which accomplishes the highest performance with low consumption and a switching capacity of 10A at AC1. The manual test tab, optionally lockable makes the CR31 the ideal relay for all control and automation uses. R/C-units and LED indication are available optionally in form of plug-in modules for the socket CS-30.
• lockable manual operation • mechanical flag indicator Test voltage: 2500V 2500V Tamb. operation/storage: -40..+60/ - 40..+80°C
MAX MIN
and others:
www.comat.ch Connection No. on socket ➞
Designation according to DIN/EN 50011➞
Connection with socket CS-30
10 A 250 V A 10mA 12V 2 8 5 3 9 6 1 7 4 22 21 24 32 31 34 12 11 14
z
= Contact opening >0,5mm
+ A1
A2 A2 14 14
13
Data at Tamb. =20°C (standard coil)
Contact material Switching power AC1/DC1 Peak inrush power Switch.cycl. mech./electr.(AC1)
AgNi 90/10 2500VA/...250W 20A(20ms) 20x106/≥105
Operation voltage DC/AC50Hz Power consumption AC/DC Trigg.delay/release time Trigg.delay/release time DC
0,75-1,7UN /0,8-1,65UN 1,0VA /0.75W AC:<25/10ms; DC:15/10ms 15/25ms
Standard
Standard
FX X
C31
24, 115, 230 / AC ..... V
≤10%
C31
24 / DC ..... V
≤ 20% ≤10%
C31D
24 / DC ..... V
AC 50/60Hz
DC DC
System socket CS-30 (connections above) 8 CO
9 7
21
M
31 11
5N
6 4
24
34
2N
3 1
O
22
C
Plug-in Socket Module R/C-Unit
14
32 12
CMX1/ UC110-240V CMX1/ UC24-60V
Clip/Marking tag CC-30
12 A 300 V
Ordering example
CS-30
LED or R/C-Module
A1 +
A2
4k7/0,01µF
CMR1/ UC110-240V
14 13
LED-Mod. CMX1/UC24-60V Retaining clip CC-30
R/C-Unit
COIL
MADE IN EU
Ind.Relay CR31/DC24V Socket CS-30 (clip incl.)
01
75
Relay
32
26
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
3
27
470E/0,22µF
CMR1/ UC24-60V
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
17
KAT 2008
Control Relay
Signal Relay
C9 Miniature
Remanence Relay
10 Au
DC 24 V D
AC 230V A
WH: 21x 28
AC 230V A
37,5
C9 -A41
C9 - A42
4-pole Miniature Industrial Relay
Universal Control Relay
• lockable manual operation • mechanical indication
with 4 changeover contacts for AC and DC circuits ranging from 10mA10V.
Test voltage: 2500V 1000V Tamb. operation/storage: -20..+60/ - 40..+85°C
C9 -R21
Relay like ..A41, but with 10 z gold plated contacts
Remanence Relay with AC or DC coil
for control and signal circuits ranging from 5mA 5V. Recommend. upto 0,2A 30V.
A1(13) = ON; A3 (10) = OFF. Minim. triggering time 50ms, permanent triggering admissible. Test voltage 2500V . Without option X.
MAX MIN
and otheres:
www.comat.ch Connection No. on socket ➞
Designation according to DIN/EN 50011 ➞
5 A 250 V A
5 A 250 V A
5 A 250 V A
10mA 10V
5mA 5V
10mA 10V
8 4 44
5 1 14
7 3 6 2 34 24
42
32
22
Connection with socket CS-114
12
= contact opening < 3mm
A1
41 31 12 14 11
7 3 6 2 34 24
42
32
+ A2
21 11 10 13 9
5 1 14
22
z
+ A2
8 4 44
12
22
21 11 10 13 9
12
z
ON
A1
41 31 12 14 11
5 1 14
8 4 24
A2 21 12 14
z
+ A1
OFF
+
A3 11 10 13 9
Data at Tamb. =20°C (standard coil)
Contact material Switching power AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi+0,2zAu 700VA/...75W 15A(10ms) 20x106/≥ 105
AgNi+10z Au 700VA/...75W 15A(10ms) 20x106/≥ 105
AgNi+0,2zAu 700VA/...75W 15A(10ms) 20x106/≥ 105
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
0,8...1,2UN 1,5VA/1W 10/6ms
0,8...1,2UN 1,5VA/1W 10/6ms
0,8...1,2UN ON:1,2VA/W; OFF: 0,3VA/W 10/8ms ( >50ms)
24, 48, 115, 230 C9-A41 X / AC ..... V
24, 48, 115, 230 C9-A42 X / AC ..... V
24, 48, 115, 230 C9-R21 / AC ..... V
≤ 10%
12, 24, 48, 110, 125 C9-A41 / DC ..... V
12, 24, 48, 110, 125 C9-A42 / DC ..... V
12, 24, 48 C9-R21 / DC ..... V
≤ 10%
12, 24, 48, 110, 125 C9-A41D X / DC ..... V
12, 24, 48, 110, 125 C9-A42D X / DC ..... V
AC
Standard
50/60Hz
DC
Standard
DC
D, DX = Type X (Option)
Option X = with
System socket CS-114 34 24 14
4
1
2
3 x 4,4
75
3
Socket for print mounting S9-P
2
1
7
6
5
12 11 10 9
CS -114
Relay C9-A41X/AC230V Socket CS-114 (clip incl.) Socket S9-P Retaining clip RC-G (option)
KAT 2008
3
14
Ordering example
18
4 8
14
13
A2
A1
9
41
11
21
13
RC-G
2
3
4
5
6
7
8
9 10 11 12 13
14
ø 1,4
12 11 10 31
S9 - P
1
4,05
5 12
0,6
7
6,35 6,35
6
42 32 22
0,5 x1,2
8
30
44
22,5
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
Clip S9-CG 3
22
37,5
22,5
4
12,6
13,2
View on solder side
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Signal Relay 3x
3,5 Au
3,5 Au
3,5 Au
Industrial Relays
Signal Relay 2x
01
KR Miniature
Signal Relay
100zA 100 mV... 3A 30V D/250 V A
+ 8 6
7
• 1- to 3-channel • for control and signal circuits • Power consumption only 250mW per channel Test voltage: 2000V 1000V Tamb. operation/storage: -20..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch
1
+
+
6
7
R
3
2
1
+
6
+ 7
5
relay
Case
1
z
3
+ 8
1 z
Case
KR 33 X /DC 24 V D
R
KR 23
B
KR 33
Universal gold plated twin contact relay
Relay like KR13, but 2-channel
Relay like KR13, but 3-channel
1-channel, totaly incapsulated. For highest switching reliability in control and signal circuits ranging from 100 A 100mV.
with a width of 11mm per channel this relay is especially space-saving and cost-effective.
with a width of 7,3mm per channel this relay is especially space-saving and cost-effective.
3A
3A
3A
250 V A // 110 V D
100 A 100mV
Connection No. on socket ➞
4 2 24 23
Designation according to DIN/EN 50011 ➞
Connectio with socket CS-18 = contact opening < 3mm
4 2 13 2 14
2
z
+
13 A1 5 7
A2 8
2
+
250 V A // 110 V D
100 A 100mV
4 2 3 1 13 2 14 1 13 1 14
3 1 14 13
A2 23 8 6
250 V A // 110 V D
100 A 100mV
z
1
z
1 A1
6
7
2
3
+
+
2 A1
3 14
3
+
A2 2 A1 8 6
3 A1
5
1 1 14
1
+
1 A1
7
)
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr. (AC1)
Ag-alloy+3..5 Au 750VA/...90W//3A 30VD 6A(20ms) 20x106/≥ 105
Ag-alloy+3..5 Au 750VA/...90W//3A 30V D 6A(20ms) 20x106/≥105
Ag-alloy+3..5 Au 750VA/...90W//3A 30VD 6A(20ms) 20x106/≥ 105
Operation voltage Power consumption per channel Triggering delay / release time
0,8...1,2UN 350mW 6/4ms (X: 6ms)
0,8...1,2UN 250mW 6/4ms (X: 6ms)
0,8...1,2UN 250mW 6/4ms (X: 6ms)
≤ 20%
12, 24, 48 KR13A / DC ..... V
12, 24 KR23A / DC ..... V
12, 24 KR33A / DC ..... V
≤ 20%
12, 24, 48 KR13X / DC ..... V
12, 24 KR23X / DC ..... V
12, 24 KR33X / DC ..... V
Socket for print mounting S7-P
System socket CS-18 4
2
3
1
Clip GC-T *)
B
2
1
4
3
6
5
8
CS-18
75
22 x 65
7
Clip RC-G
10
Case
24 22 14 12
2
1
4
3
Case
6
R
8
5
S7- P
7
RC-G
1
2
3
4
5
6
7
8
0,6
DC
0,5 x 2
X
DC
30
A
7,25 5,9 4,7
Data at Tamb. =20°C (standard coil
1 z
2 8
KR13 Miniature Industrial Relay
3
z
Case
01
35,5
5
2
100zA100mV...3A30VD/ 250VA
z
4
2 z
01
3 1
KR23X/DC24V D
4 2
100zA100mV...3A30VD/ 250VA
WH: Geh.R: 22 x 28 Geh.B: 22 x 65
KR13X/DC24V D
4
ø 2,2
22 x 28 22,5
5,2
13,1
14,5
Ordering example Clip GC-W *)
Relay KR23X/DC24V Socket CS-18 or S7-P Retaining clip RC-G (option)
View on solder side
21 11
8A2 6B1 5 7A1
22,5
3
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
22
35,5
*) Standard delivery with relay (Case B)
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
19
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
20
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Standard Relays
1
Standard Relays Recommended application 16 A 10 A 6A 1A 10 mA 5 mA 1mA
Series
2
C2-A20 C3-R20
C2-T21
3
C3-A30
C3-T31
4
C4-A40
C5-M10 C3-T32
C5-A30
twin contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
21
KAT 2008
8
C2 Standard
Power Relay
Control Relay
DC 24V D
WH: 35 x 35
AC 230 V A
58
C2-A20 2-pole Miniature Industrial Relay according to IEC 67-1 • lockable manual operation • mechanical flag indicator Test voltage: 2500V 2500V Tamb. operation/storage: -20..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch Connection No. on socket ➞
designation according to DIN/EN 50011 ➞
Connection with socket EC-8
C2-T21
Universal Power Relay 10 A
Relay like .. A20, but with doubel contacts 6A
With 2 power changeovercontacts this is the robust relay for AC and DC circuits ranging from 10mA10V.
The control relay with highest switching reliablility for control and signal circuits ranging from 5mA 5V.
10 A 250 V A
6 A 250 V A
10mA 10V
5mA 5V
6 5 4 3 24 22 12 14
6 5 4 3 24 22 12 14
z
z
+
+
= contact opening < 3mm
A2 21 7 8
Data at Tamb. =20°C (standard coil
A2 21 7 8
11 A1 1 2
11 A1 1 2
)
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi 2500VA/...250W 30A(20ms) 20x106/ ≥ 5x105
AgNi+0,2zAu 1200VA/...150W 15A(20ms) 20x106/ ≥ 2x105
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
0,8...1,2UN 2,2VA/1,3W 16/8ms
0,8...1,2UN 2,2VA/1,3W 16/8ms
AC
Standard
Standard
C2-T21
24, 48, 115, 230 X / AC ..... V
C2-A20
DC ≤ 10%
12, 24, 48, 110, 125, 220 C2-A20 / DC ..... V
12, 24, 48, 110, 125, 220 C2-T21 / DC ..... V
≤ 10%
12, 24, 48, 110, 125, 220 C2-A20D X / DC ..... V
12, 24, 48, 110, 125, 220 C2-T21D X / DC ..... V
DC
D, DX
24, 48, 115, 230 X / AC ..... V
50/60Hz
= Type “ X ” (option)
Option X = with
02
Economy socket EC-8 6
5
4
3
24
22
12
14
EC-8
10 A 10 A 400 V 300 V Listed
62
10 A 400 V
Clip S3-C
Ordering example Relay C2-A20X/AC230V Socket EC-8 Retaining clip S3-C (option)
22
KAT 2008
A2
21
11
A1
7
8
1
2
38
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
4
22
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
11
C3 Standard
Power Relay
Control Relay
Remanence Relay
Signal Relay
DC 24 V D
AC 230 V A
DC 24 V D
WH: 35 x 35
AC 230 V A
Industrial Relays
10 Au
58
SEISMIC
C3-A30 3-pole Miniature Industrial Relay according to IEC 67-1 • lockable manual operation • mechanical flag indicator 2500V 2500V Test voltage: Tamb. operation/storage: -40..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch
C3-T32
C3-R20
Relay like .. T31, but with 10 gold plated contacts
Remanence Relay 10 A with AC or DC coil
With 3 power changeovercontacts this is the robust relay for AC and DC circuits ranging from 10mA10V.
The control relay with highest switching reliablility for control and signal circuits ranging from 5mA 5V.
The twin contact relay with highest switching reliability for signal circuits ranging from 1mA 5V. Recommend. upto 0,2A 30V.
A1(2)=ON; A3(6)=OFF. Minim. triggering time 50ms, permanent triggering admissible. Without option X.
10 A 250 V A
6 A 250 V A
6 A 250 V A
10 A 250 V A
10mA 10V
5mA 5V
1mA 5V
10mA 10V
9 8 7 5 3 4 34 32 24 22 14 12
9 8 7 5 3 4 34 32 24 22 14 12
9 8 7 5 3 4 34 32 24 22 14 12
9 8 24 22
z
z
z
z
+
A2 31 10 11
Data at Tamb. =20°C (standard coil
C3-T31 Relay like .. A30, but with twin contacts 6A
Designation according to DIN/EN 50011 ➞
= contact opening < 3mm
1
ED
Universal Power Relay 10 A
Connection No. on socket ➞
Connection with sockets EC-11, C11A, C12B
APPROV
A2 31 10 11
21 11 A1 6 1 2
+
21 11 A1 6 1 2
OFF
+
A2 31 10 11
3 4 14 12
+
21 11 A1 6 1 2
ON
+
A2 21 A3 11 A1 10 11 6 1 2
)
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi 2500VA/...250W 30A(20ms) 20x106/ ≥ 5x105
AgNi+0,2 z Au 1200VA/...150W 15A(20ms) 20x106/ ≥ 2x105
AgNi+10z Au 1200VA/...150W 15A(20ms) 20x106/ ≥ 2x105
AgNi 2500VA/...250W 30A(20ms) 20x106/ ≥ 3x105
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
0,8...1,2UN 2,2VA/1,3W 16/8ms
0,8...1,2UN 2,2VA/1,3W 16/8ms
0,8...1,2UN 2,2VA/1,3W 16/8ms
0,8...1,2UN ON/OFF 1,5/0,5 VA//W 16/10ms ( >50ms)
Standard
Standard
D, DX
AC
24, 48, 115, 230 X / AC ..... V
50/60Hz
C3-A30
DC ≤ 10%
12, 24, 48, 110, 125, 220 C3-A30 / DC ..... V
≤ 10%
12, 24, 48, 110, 125, 220 C3-A30D X / DC ..... V
DC
24, 48, 115, 230 X / AC ..... V
24, 48, 115, 230 C3-R20 / AC ..... V
12, 24, 48, 110, 125, 220 C3-T31 / DC ..... V
12, 24, 48, 110, 125, 220 C3-T32 / DC ..... V
12, 24, 48, 110, 125 C3-R20 / DC ..... V
12, 24, 48, 110, 125, 220 C3-T31D X / DC ..... V
12, 24, 48, 110, 125, 220 C3-T32D X / DC ..... V
C3-T31
24, 48, 115, 230 X / AC ..... V
C3-T32
Option X = with
= Type “ X ” (option)
Types C3-A30 comply to IEE 323 and IEE 344. (seismic qualified)
System socket C11A *) 5
3
4
22
14
12
Economy socket EC-11
6
3
7
5
3
4
24
22
14
12
10 A 10 A 400 V 300 V Listed
10 A 400 V
04
4
8 32
EC-11
5
75
7 8 9
9 34
02
7 24
30
8 32
10A 250VA
9 34
SWISS
For suitable coil wirings see “R-modules” page 31
Clip S3-C
11
10A 400VA
1
CONNECTOR
C-A2
C-A2
Ordering example SD -1W
Relay C3-A30X/AC230V Socket EC-11 or C11A Retaining clip S3-C (option)
A2
10
31
21
11
A1
11
6
1
2
38
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
4
20
*) with plugged-in neutral conductor connector C-A2 (standard delivery).
Clip S3-C
32
2
10
C11A
A2
31
21
11
A1
10
11
6
1
2
38
4
22
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
23
KAT 2008
Power Relay C4 Standard
WH: 35 x 35
AC 230 V A
50
C4 -A40 4-pole Industrial Relay with faston pins
Universal Power Relay 10 A
• lockable manual operation • mechanical flag indicator
With 4 power changeovercontacts this is the robust relay for AC and DC circuits ranging from 10mA10V.
Test voltage: 2500V 2500V Tamb. operation/storage: -40..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch Connection No. on socket ➞
Designation according to DIN/EN 50011 ➞
10 A 250 V A 10mA 10V 11 10 8 7 5 4 44 34 24 42
32
22
Connection with socket CS-14 = contact opening < 3mm
21 11 6 13 3
)
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi 2000VA/...250W 30A(20ms) 20x106/ ≥ 6x105
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / Release time
0,8...1,2UN 2,4VA/1,4W 20/8ms
AC 50/60Hz
24, 48, 115, 230 C4-A40 X / AC ..... V
≤ 10%
12, 24, 48, 110, 125, 220 C4-A40 / DC ..... V
≤ 10%
12, 24, 48, 110, 125, 220 C4-A40D X / DC ..... V
DC DC
D, DX
z
A1
41 31 12 14 9
Data at Tamb. =20°C (standard coil
Standard
12
+ A2
Standard
2 1 14
= Type “ X ” (option)
Option X = with
Socket CS-14 11 44 8 34 5 24 2 14
10
7
4
1
11
8
5
2
9
6
12
92
10 42 7 32 4 22 1 12
3 14
13 CS-14
14 A2
Ordering example Relay C4-A40X/AC230V Socket CS-14
24
KAT 2008
Clip S3-CMG
13 A1
12 41 9 31 6 21 3 11
38
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
4
28
50
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
High Power Relay for AC and DC 16 A 400 VA
10 A @ 220 VD
DC 24 V D
WH: 35 x 35
AC 230 V A
Industrial Relays
C5 Standard
50
C5 -A30 3-pole Industrial Relay with faston pins
Universal Power Relay 16 A
• lockable manual operation • mechanical flag indicator
With 3 power changeovercontacts this is the robust relay for AC and DC circuits ranging from 10mA10V.
Test voltage: 4000V 4000V Tamb. operation/storage: -40..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch Connection No. on socket ➞
Designation according to DIN/EN 50011 ➞
Highpower Relay, in particular for DC loads upto 10 A 220 V D (DC1) With 2 contacts in seires and a blow magnet for safe arc extinguishing.
16 A 500 V A / 6 A AC15
16 A 500 V A / 6 A AC15
10mA 10V
10mA 10V 4 1 14
6 3 5 2 34 24 32
22
6 13
S N
4 14
12
Connection with socket CS-15
z
+
A2 = contact opening < 3mm (1,7+1,7)
Data at Tamb. =20°C (standard coil
1
C5 - M10
+
A1
31 21 9 B 8
A2
11 7 A
B
A1 A
)
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi 4000VA/...400W 40A(20ms) 20x106/ ≥ 3x105
AgNi 4000VA/...880W 40A(20ms) 20x106/ ≥ 3x105
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / Release time
0,8...1,2UN 2,4VA/1,4W 20/10ms
0,8...1,2UN 2,4VA/1,3W 20/10ms
Standard
Standard
D, DX
24, 48, 115, 230, 400*) C5-A30 X / AC ..... V
24, 48, 115, 230, 400*) C5-M10 X / AC ..... V
≤ 10%
12, 24, 48, 110, 125, 220 C5-A30 / DC ..... V
12, 24, 48, 110, 125, 220 C5-M10 / DC ..... V
≤ 10%
12, 24, 48, 110, 125, 220 C5-A30D X / DC ..... V
12, 24, 48, 110, 125, 220 C5-M10D X / DC ..... V
AC 50/60Hz
DC DC
= Type “ X ” (option)
Option X = with
*) 400V available only without LED ( X ) !
Socket CS-15 6 34
5 24
3 32
2 22
4 14 1 12
80
CS-15
Ordering example Relay C5-A30X/AC230V Socket CS-15
B A2 9 31
A A1 8 21
Clip S3-CMG
7 11
38
3,5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
26,5
50
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
25
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
26
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Long Life Relays
1
Longe Life Relays Recommended application 10 A 6A 5A 1A 10 mA 5 mA 1mA 2
C21
C22
3
C31
C32
2x 1
C33
3x 1
C34 C39
twin contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
27
KAT 2008
8
C20 Long Life
Power Relay
Control Relay
THE UN LOCK
12345
8 21
RELAY A1 2+ 7 A 2 ..D ..L
1 11
C21L / AC 230 VA 220 -240V 50/60Hz 312
• lockable manual operation • mechanical flag indicator Test voltage: 2500V 1500V Tamb. operation/storage: -40..+70/ - 40..+85°C
MAX MIN
and others:
www.comat.ch Connection No. on socket ➞
Designation according to DIN/EN 50011 ➞
Connection on sockets EC-8
C22 Relay like .. C21, but with twin contacts 6A
with 2 power changeovercontacts this is the robust relay for AC and DC circuits ranging from 10mA10V.
The control relay with highest switching reliablility for control and signal circuits ranging from 1mA 5V.
10A 250V /4A 440V A
6A 250V A
10mA 10V
1mA 5V
6 5 4 3 24 22 12 14
6 5 4 3 24 22 12 14
z
z
A2 21 7 8
Data at Tamb. =20°C (standard coil
1 11
Universal Power Relay 10 A
+
+
= contact opening < 3mm
8 21
C22DL / DC 24VD 480 723
C21 2-pole Industrial Relay according to IEC 67-1
6 A 250 V AC1 Ag Ni 24 22 14 12 6 5 3 4
A2 21 7 8
11 A1 1 2
11 A1 1 2
)
Contact material Switching power AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1)
Ag (AgCuNi) 2500VA/...300W 40A(20ms) 100x106/ ≥ 7x105
Ag (AgCuNi) 1500VA/...200W 15A(20ms) 100x106/ ≥ 1,5x105
Operation voltage AC 50 Hz / DC Power consumption Triggering delay / release time
0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms
0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms
AC
Standard
Standard
24, 48, 115, 230 L / AC ..... V
24, 48, 115, 230 L / AC ..... V
50/60Hz
C21
DC ≤ 10%
12, 24, 48, 110, 220 C21 / DC ..... V
12, 24, 48, 110, 220 C22 / DC ..... V
≤ 10%
12, 24, 48, 110, 220 C21D L / DC ..... V
12, 24, 48, 110, 220 C22D L / DC ..... V
DC
D, DL = Type “ L ” (option)
C22D5
...L
10 A 400 V AC1 Ag Ni 24 22 14 12 6 5 3 4
C21A 5
WH: 35 x 35
51
RELAY
ONES
LOCK
12345 A1 2 7N A2
IN
TIBLE C U R T S DE
C22
Option L = with
02
Economy socket EC-8 6
5
4
3
24
22
12
14
EC-8
10 A 10 A 400 V 300 V Listed
62
10 A 400 V
Clip HF-32
Ordering example Relay C21/AC230V Socket EC-8 Retaining clip HF-32 (option)
28
KAT 2008
A2
21
11
A1
7
8
1
2
38
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
4
22
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
C30 Long Life
Power Relay
Control Relay
THE UN LOCK
12345
...L
11 31 6 21
RELAY A1 2+ 10 A 2 ..D ..L
1 11
C31L / AC 230 VA 220 -240V 50/60Hz 312
• lockable manual operation • mechanical flag indicator Test voltage: 2500V 1500V Tamb. operation/storage: -40..+70/ - 40..+85°C
MAX MIN
and others:
www.comat.ch
1
C32
with 3 power changeovercontacts this is the robust relay for AC and DC circuits ranging from 10mA10V.
The control relay with highest switching reliablility for control and signal circuits ranging from 1mA 5V.
10A 250V /4A 440V A
6A 250V A
10mA 10V
1mA 5V
9 8 7 5 3 4 34 32 24 22 14 12
9 8 7 5 3 4 34 32 24 22 14 12
z
z
+
A2 31 10 11
Data at Tamb. =20°C (standard coil
939
Relay like .. C31, but with twin contacts 6A
Designation according to DIN/EN 50011 ➞
= contact opening < 3mm
1 11
Universal Power Relay 10 A
Connection No. on socket ➞
Connection on sockets EC-11, C11A, C12B
11 31 6 21
C32/DC24VD 480
C31 3-pole Industrial Relay according to IEC 67-1
6 A 250 V AC1 Ag Ni 34 32 24 22 14 12 9 8 7 5 3 4
A2 31 10 11
21 11 A1 6 1 2
+
21 11 A1 6 1 2
)
Contact material Switching power AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1)
Ag (AgCuNi) 2500VA/...300W 40A(20ms) 100x106/ ≥ 7x105
Ag (AgCuNi) 1500VA/...200W 15A(20ms) 100x106/ ≥ 1,5x105
Operation voltage AC 50 Hz / DC Power consumption Triggering delay / release time
0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms
0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms
Standard
Standard
D, DL
24, 48, 115, 230 L / AC ..... V
AC
24, 48, 115, 230 L / AC ..... V
50/60Hz
C31
DC ≤ 10%
12, 24, 48, 110, 220 C31 L / DC ..... V
12, 24, 48, 110, 220 C32 / DC ..... V
≤ 10%
12, 24, 48, 110, 220 C31D L / DC ..... V
12, 24, 36, 48, 110, 220 C32D L / DC ..... V
DC
C32
Option L = with
= Type “ L ” (option)
Railway D/R
C32D5
10 A 400 V AC1 Ag Ni 34 32 24 22 14 12 9 8 7 5 3 4
RELAY
C31A 5
WH: 35 x 35
51
ONES
LOCK
12345 A1 2 10 N A2
IN
CTIBLE D E ST R U
Industrial Relays
11
DC ≤ 10%
24, 36, 110 C31D/R DC ..... V
24, 36, 110 C32D/R DC ..... V
The railway-relays C31D/R DC comply to fire protection standards according NFF 16101/2 and ISO 9125/2.
System socket C11A *) 7
5
3
4
24
22
14
12
Economy socket EC-11
6
7
3
8
7
5
3
4
32
24
22
14
12
10 A 10 A 400 V 300 V Listed
10 A 400 V
04
4
9 34
EC-11
5
8 9
75
SWISS
10A 250VA
For suitable coil wirings see “R-modules” page 31
02
8 32
30
9 34
Clip HF-32
11
10A 400VA
1
CONNECTOR
C-A2
C-A2
Ordering example SD -1W
• Relay C31/AC230V • Socket EC-11 or C11A • Retaining clip HF-32 (option)
A2
10
31
21
11
6
11
1
A1
2
38
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
4
20
*) with plugged-in neutral conductor connector C-A2 (standard delivery).
Clip HF-32
32
2
10
C11A
A2
31
21
11
A1
10
11
6
1
2
38
4
22
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
29
KAT 2008
9
7
8
3
5
R2 R1
Control Relay 2x
4
9
8
7
5
R2 R1
3
Control and Signal Relay 3x
4
9 11
51
relay
• Single or twin contacts • Front contact inspection window or LED display (C39) Test voltage: 2000V 2000V Tamb. operation/storage: -25..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch
3
R1 4
11+
6+
relay
2+
1
C39 / DC 24 V D
C39
Double-channel Power Relay 10 A
Relay like C33, but with twin contacts 5 A
Triple-channel Twin Contact Relay 5 A
With 2x1 power changeovercontacts this is a robust relay for AC and DC circuits ranging from 10mA12V. Width per channel: 17,5mm.
The control relay with highest switching reliablility for control and signal circuits ranging from 1mA 6V. Width per channel: 17,5mm.
with 3x1 No contact it is ideal for interface applications ranging from 1mA 100mV. LED display for each channel. Width per channel: 11,7mm.
10 A 250 V A
5 A 250 V A
5 A 250 V A
10mA12V
1mA 6V
1mA100mV
9
Designation according to DIN/EN 50011 ➞
2 14 2 12
75 3 4 1 14 1 12
2
1
Connection on sockets EC-11, C11A, C12B
8
z
+
A2 211 2 A1 10 11 6
Data at Tamb. =20°C (standard coil
10
C 34 / AC 230 V A
C34
Connection No. on socket ➞
= contact opening < 3mm
R2 5
7
2 1
04
relay
C 33 / AC 230 V A
C33 2- and 3-channel Industrial Relays according to IEC 67-1
N 10
6
5 A 250 V A
10 A 250 V A
2 1
04
WH: 35 x 35
N 10
6
11
R3 8
1 11 1
75 3 4 1 14 1 12
2
1
9
z
+
8
+
A2 211 2 A1 10 11 6
A1 2
1
2 14 2 12
1 11 1
1
+
A1 2
9
8
7
5
3 4
3 14 3 13 2 14 2 13 1 14 1 13
z
3
2
+
1
+
A2 3 A1 10 11
+
A1 1 A1 6 1 2
2
)
Contact material Switching power AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1)
AgCdO 2500VA/...300W 40A(16ms) 20x106 / ≥ 105
AgNi 1250VA/...200W 20A(16ms) 20x106 / ≥ 105
Ag-alloy 1250VA/...150W 10A(20ms) 50x106 / ≥ 1,5x105
Operation voltage AC 50 Hz / DC Power consumption per channel Triggering delay / release time
0,8...1,15UN 1,3VA/0,55W 15/25ms
0,8...1,15UN 1,3VA/0,55W 15/25ms
0,8...1,2UN 0,25W 8/12ms
AC 50/60Hz
DC ≤ 10%
C39
5 A 250 V A
C33,34,39 Long Life
Power Relay 2x
05
11
24, 48, 115, 230 C33 / AC ..... V
24, 48, 115, 230 C34 / AC ..... V
12, 24, 48, 110 C33 / DC ..... V
12, 24, 48, 110 C34 / DC ..... V
12, 24, 48 C39 / DC ..... V
System socket C11A *) 5
3
4
22
14
12
Economy socket EC-11
3
7
5
3
4
24
22
14
12
10 A 10 A 400 V 300 V Listed
10 A 400 V
04
4
8 32
EC-11
5
75
SWISS
6
7 8 9
9 34
30
7 24
02
8 32
10A 250VA
9 34
Clip HF-32
11
10A 400VA
1
CONNECTOR
C-A2
C-A2
Ordering example SD -1W
Relay C34/AC230V Socket EC-11 or C11A Retaining clip HF-32 (option)
30
KAT 2008
A2
10
31
11
21
6
11
1
A1
2
38
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
4
20
*) with plugged-in neutral conductor connector C-A2 (standard delivery).
Clip HF-32
32
2
10
C11A
A2
31
21
11
A1
10
11
6
1
2
38
4
22
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Time Cubes and R elay Modules
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
1
Timing Functions (0,2s-30min) Delay functions
E
Shot timing modes
On delay
t
www.comat.ch
A
S R
S ⇒ R on with delay S OFF ⇒ R off
S R
S ⇒ R on S OFF ⇒ R off with delay
W
t
S R
S ⇒ R on for t S OFF ⇒ R off (pulse clipping)
S R
S ⇒ R on/off periodically according to t S OFF ⇒ R off
Off delay
t Pulse shaping
K
One shot leading edge
Blinker functions
Pulse shaping
t COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
S R
S (pulse or continuous contact) ⇒ R on for t S no influence on R and t
B
Blinker, pulse start
t t t
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
31
KAT 2008
CT2/CT3 Time Cubes
8
Plug-in Time Cubes
11
PLUGED SIMPLY N BETWEE 0,2 s - 30 min
0,2 s - 30 min
0,2-3s/min • 2-30s/min
0,2-3s/min • 2-30s/min
On delay
Industrial relay Time cube ®
CT2 (8-pin) 8- /11-pole Plug-in Time Delay Relay System
S ⇒ R on with delay S OFF ⇒ R off
CT3 (11-pin) RELAY
RELAY
The simplest time delay relay sys-tem world-wide, fitting all 8 or 11-pin relay sockets (octal/sub-magnalite). Original time cubes ® are simply placed between socket and relay without rewiring. In this way, even as a retrofit, all industrial relays can be provided with the required timing functions without additional space being required. The contact connections of the relay on the socket remain through-connected.
CT2 7
2
A2 7
A1 2
S B1
+
Socket
CT3 10
<
A2 10
A1 2
One shot leading edge S W t R
+
10A 250 V A
Triggering
E
CT .. - E 30 / ...
A
CT .. - A 30 / ... CT .. - K 30 / ...
H
DC9,5-18V
2 = 8 - pole 3 =11- pole
Function
UC20-65V
Order no.
UC90-265V
S ⇒ R on for t S OFF ⇒ R off (pulse clipping) UC90-150V
MAX
L
S
U M
L
S
U M
L
S
Pulse shaping
K
+
S
Blinker, pulse start
+
K
UC AC/DC
DC
W
W
CT.. -W30 / ...
H
L
S
B
CT .. - B 30 / ...
H
L
S
10%
S ⇒ R on/off periodically according to t S OFF ⇒ R off
ON
Industrial relay
Socket
EC-8
Ordering example
EC-11
6
5
4
3
9
8
7
5
3
4
24
22
12
14
34
32
24
22
14
12
EC-8
EC-11
10 A 10 A 400 V 300 V Listed
10 A 10 A 400 V 300 V Listed
10 A 400 V
62
10 A 400 V
Time cubes CT2-E30/H Socket EC-8 or CS-8
S = Triggering R = Output circuit ⇒ = switches...
OFF
02
CT2 / 3
S R
t t t
B
Clip
32
Relay C2-... Time cubes CT3-E30/H Sockel EC-11 oder C11A Relay C3-...
32
KAT 2008
02
S
t
30
S
S R
S (pulse or continuous contact) ⇒ R on for t S no influence on R and t
A2 A1 A2 B1 A1 A2 B1 A1 +
S R
t
S ⇒ R on S OFF ⇒ R off with delay
S B1
Socket
UC180-265V
and others:
41 3 567 8 11 9
413 586
A
All new types ..30 (0,2s-30min) are fully compatible with all previous types ..20, ..21 and ..25.
www.comat.ch
Off delay
4 1 3 5 6 7 8 119
413 58 6
S R
t
E
S3-CT For Relay C2...C3
HF-33 For Relay* C21...C39
58 ( 51* )
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
25
22
4
A2
21
11
A1
A2
31
21
11
A1
7
8
1
2
10
11
6
1
2
38
38
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Relay modules indicate the relay’s switch mode and /or help limiting cutoff voltage peaks in the control circuit by means of a diode or a RC module. The types R..2/3 are equipped with additional diodes for signal or OR-circuits. For parallel or serial connections the relay modules are simply plugged info the sockets C11A or C12B.
System socket C11A
System socket C12B
2
10
Industrial Relays
R-Module Supplementary products
Plug-in coil wirings for 3-pole Industrial Relays C3, C31 and C30
11
1
2
10
Industrial relay R-module
R-module 02
Module section
Module section
2 15k
1N4007 1000 V 1A
RDL1 / DC 48VD
A2
Relay coil ➞
Illuminated displays
A2
A1
12
A1
/
RL1/ AC 110 -240 V a 10
RL1/ UC12-24 V u
2
150k
A2
10
A1
2
6k8
see RL1/UC...V
A2
A1
RC1/ UC 110 -240 V u
Suppressing units
10
470E
RD1/ DC12 -220 V d
2
0,1µF
2
10
see RC1/UC...V A2
A1
47E
A2
A1
With additional diode output (12), e.g. for collective alarm messages.
With additional diode input (12), e.g. as logical addition.
RD2 / DC12 -220 V d
RD3 / DC12 -220 V d
2
10 47E
A2
12
A1
2
10 47E
A2
12
A1
RC1/ UC 12- 48 V u 10
47E
2
0,47µF
A2
Suppressing units with illuminated displays
RCL1/ AC 110 -240 V a 10
470E
RCL1/ UC 24 V u 10
2
0,1µF
A2
A1
A1
RDL1/ DC12-24 V d 2
47E 0,47µF
A2
A1
10k
A1
22k
Current types
6k8
12
A1
A2
6k8
12
A1
2
10 A2
A1
15k
8
7
5
3
4
9
8
7
5
3
4
34
32
24
22
14
12
34
32
24
22
14
12
+ +
5
6
7
Clip S3-C
5
4
8
4
3
9
3
04
05
8
75
6
7
SWISS
10 A 250 VA
12345
9
2
10
C11A
+
System socket C12B
9
SWISS
+
(+) L
N( )
L
12345
11
2
10 10 A 400 V A
1
CONNECTOR
C 12 B
C-A2
11
10 A 400 V A
1
CONNECTOR
C-A2
C-A2
Ordering example Module section
Relay Type C3-... Clip S3-C (option)
6k8
2
10
/ N
System socket C11A
Module RCL1/UC48V Socket C11A
A2
10 A 250 VA
Triggering
2
47E 0,47µF
A2
A1
2
10
RDL1/ DC 48 V d
RCL1/ UC 48 V u 10
A2
RDL3 / DC12-24 V d
RDL2 / DC12-24 V d 2
10
Module section
A2
31
21
11
A1
A2
31
21
11 B1
10
11
6
1
2
10
11
6
1
Plugged-in neutral conductor connector C-A2 (C11A standard delivery).
A1
Module section 38
38
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
12
2
4
20
Jack on the socket Plug pin on the R-module
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
33
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
34
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
DIN Relays
1
DIN Relays Recommended application
Stepping switch
6A 5A 3A 2A 1A 10 mA 1mA 100 µA 1
CR16 C103.01
CRS1C
C103.06
2
C133.01
CR23
2x 1
C203.01
CR33
3x 1
CR11 C203.04
C203.06 C301.04
twin contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
35
KAT 2008
Power Relay CR.. DIN Interface
Control Relay 2x / 3x
DIN
Signal Relay
Step-on / Step-off Relay
T BASE
WITHOU
13 mm
CR16 AX CR16 CX DIN Interface Relais • No external coil wiring required • Mounting on DIN rail TS 35 Test voltage:
2000V 2000V
MAX MIN
and others:
CR 33 A
CR11C
CRS1C
Power Relay
Control Relay (Signal relays)
Signal Relay
Stepping Relay
13mm series, 1 x NO resp. 1 x CO up to 6A. Integrated LED and coil wiring.
13 mm series, 2/3 channel, each 1 x NO Au twin contact. Recommended max. load 200mA/24V resistiv. Integrated LED and coil wiring.
13mm series,1 channel, 2 x CO Au twin contact. Recommended max. load 200mA/24V, resistiv. Integrated LED and coil wiring.
13mm series, 1 x CO suitable for permanent energizing. Supply loss safe. Integrated LED and coil wiring.
6 A 250 V A
3 A 250 V A
1A 250 V A
6 A 250 V A
10mA 12V
100 A 100mV
100 A 10mV
10 mA 12 V
Tamb. operation/storage: -20..+60/-40..+85°C
www.comat.ch
CR 23 A
13
14
14 12
11 12
1
13 14
2
13 14
12 14
13 3 14 1 14 2 14
11
14 12
22 24
11 12
21
+ A2
A1
+
+ A2
A1
+
1 A1
2 A1
A2
A2
+
+
1 A1
2 A1 A2 3 A1
11 A2
21 + A1
(DC-version)
z = contact opening < 3mm
(DC-version)
(DC-version)
Connection
+ A2
A1
01
Data at Tamb. =20°C
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi 1500VA/...180W 15A/20ms 30x10 6 / ≥ 1,5x10 5
Ag-alloy/Au3 m 750VA/...90W — 20x10 6 / ≥ 1,5x10 5
Ag-alloy/Au5 m 65VA/...30W — 200x10 6 / ≥ 10 5
AgNi 1500VA/...180W 15A/20ms DC:10x10 6; AC:10 5 / ≥ 10 5
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
AC –20%+10%/DC ±15% 2,5VA/0,25W 10ms /20ms
— /DC ±20% 0,25W 6ms /4ms
— /DC ±25% 0,25W 3ms /4ms
AC ±15%/DC ±15% 2VA/1,5W
DC ≤ 10%
AC 50/60Hz
24 CR16AX CR16CX / DC..... V
24 CR 23A CR33A / DC..... V
230 CR16AX CR16CX / AC ..... V
24 CR11C / DC ..... V
Recomm. triggering time ≥ 50ms
24 CRS1C / DC ..... V 230 CRS1C / AC ..... V
BS13-K BS13-G (incl. paper)
90
11
45
44
13
Ordering example Relay CRS1C/AC230V
36
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Power Relays 2x
DIN
Signal Relays 2x Industrial Relays
C100...300 DIN Interface
Control Relays 2x 3x
1
C103.01 C133.01 C203.01 DIN Interface Relay • No external coil wiring required • Mounting on DIN rail TS 35 Test voltage:
2000V 2000V
C203.04 C301.04
Power Relay
Control Relay
Signal Relay
DIN series 17,5mm, 1/2 channels with 1/2 x CO contacts up to 6A. Integrated LED and coil wiring.
High efficient 2/3 channel control relay DIN series 17,5mm, each 1 x CO resp. 1 x NO twin contact. Multi-layer contact up to 5A. Very versatile in application. Integrated LED and coil wiring.
DIN series 17,5mm, 1/2 channel each 1 x CO Au twin contact. Recommended max. load 200mA/24V. Integrated LED and coil wiring.
6 A 250 V A
5 A 250 V A
2 A 125 V A
10 mA 24 V
1mA 0,1V
10 A 10mV
Tamb. operation/storage: -20..+60/-40..+85°C
MAX MIN
and others:
www.comat.ch
C103.06 C203.06
A2
A1
A2
A1
A1 A1 A2
A1 A1 A2
A2 A2 A2
1 2
1 2
A1 A1 A1
Connection 1 z = contact opening < 3mm
11 12 14
11 12 14
21 22 24
11 12 14
1 11 12 14
2 11 12 14
1 2
A1
A2
A1 A1 A2
1 2
3
1 11 12 14
14 14 14
2 11 12 14
2 13 13 13
11 12 14
11 12 14
Data at Tamb. =20°C
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1)
AgNi 1500VA/...300W 15A/20ms 20 x10 6 / ≥ 10 5
Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
0,85...1,15UN ≤ 0,6W ≤ 1,7W 10ms /10ms
50/60Hz
/
0,8...1,2UN 0,25W (per channel) 10ms /20ms
110-127, 220-240 C203.01 / AC ..... V
C103.06
110-127, 220-240 C203.06 / AC ..... V
24, 36, 48 C203.01 / UC ..... V
C103.06
24, 36, 48 C203.06 / UC ..... V
12 C203.01 / DC ..... V
C103.01
C133.01
C103.01
C133.01
UC
0,8...1,2UN 0,25W (per channel) 6ms /30ms
12 C203.06 / DC ..... V
C133.01
AC
Ag-alloy/Au3 m 250VA/...60W — 100 x10 6 / ≥ 10 5
C103.06
C103.01
DC ≤ 10%
2x ≤ 0,6W
Ag-alloy 1250VA/...150W 10A /20ms 50 x10 6 / ≥ 1,5 x10 5
12-15, 24, 48 C203.04 C301.04 / DC ..... V
C103
75
LABEL
Ordering example 4,2
17,5
2,5
C103
Relay C301.04/DC24V
5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
64
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
37
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
38
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Solide- State Relays
1
Solide-State Relays Recommended application 5A 3A 2,5A 2A 1,5A 1A 800A 250mA 30 mA 10 mA 5 mA 2mA 1mA 1x Triac
C35
2 x Triac 1x PNP
KA115
KA108
KA208 C37
KD125
2 x PNP
CPF11 C38
3 x PNP
KD215 KD315
1+1 PNP
KDM3-24
1x co PNP
KDW3-24
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
C36
CTV11
CPF22 C301.08 C311.08
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
39
KAT 2008
9
3 4 0,8 A 265 VU
8
3
DC Solid-State Relay 1x
DC10-32 Vd +
+
DC10-32 Vd
4
0,8 A 265 V A
K
10 N
2
Solid-State
04
Solid-State
51
Tamb. operation/storage: -25..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch
1
PNP
2
C36
5
RL
RL
3
9
5A
K
PNP
Solid-State
10
relay C36 / AC110-240V A
C35 • LED display for each channel • operation voltage range 0,8..1,1UN • galvanically decoupled control (2kV)
6
10 N
relay C35 /AC110-240V A
1- and 2-channel Solid-state Relay according IEC67-1
R1
04
WH: 35 x 35
7 R2
DC Solid-State Relay 2x
2+
K
2A
RL 5
7
3
R2
R1
6+
10
Solid-State
2+
1
05
C35...C38 Solid-State
Universal Solid- AC Solid-State State Relay Relay 1x 2x
05
11
relay C38 / UC110-240V U
relay C37/ UC110-240V U
C37
C38
Universal Solid-State Relay for AC or DC load
AC Solid-State Relay double-channel
DC Solid-State single-channel
DC Solid-State Relay double-channel
Highest switching frequency virtually limitless due to solidstate operation. No external protective wiring required.
Triac output, crossover switching. Built-in RC wiring protection. Especially for bulb-loads and high switching frequencies. • Minimum load: 30mA
Bounce-free and non wearing for DC loads (inductive/ capacitive). Short-circuit/overload proof. No external wiring protection required.
Construction, characteristics and application like C37, but double-channel. 2A constant current per channel.
0,8 A 10 ... 265 V U
0,8 A 20 ... 265 V A
5 A 10 ... 32 V D
2 A 10 ... 32 V D
1mA 10V
30mA 10V
1mA 5V
1mA 5V
N RL
+ Connection No. on socket ➞
3
4
Designation according to DIN/EN 50011 ➞
14
13
L
N RL
9 14
2
RL
L
2
8 13
1
3 14
2
Connection on sockets EC-11, C11A, C12B
1
4 13
7
5 3
+ 13 14
2
2kV
2kV
RL
9 14
7
1+2
A2 10
2
5
3
+ 13
2
2kV
1 14
A1 6
2
A2
1 A1 1 A1
1
2
+ A2 10
A1
10
2kV
1
+
+ A1
10
RL
+
1
2kV
A2
RL
+
2
+
A1 A2 6 1
2
1 A1
2
Data at Tamb. =20°C
Peak inrush power Voltage drop Residual current Short-circuit proof K
1,5A /1s ≤ 3V ≤100 A ≤12A /200 s
8A /20ms ≤1,5V ≤ 3mA —
Control voltage Frequency range Control current Triggering delay Off delay
110-240V 50..60Hz ≤ 35mA ≤ 20ms ≤ 80ms
110-240V 50..60Hz ≤ 17mA ≤ 30ms ≤ 40ms
AC 50/60Hz
UC /
24-48V 40..400Hz ≤ 20mA ≤ 20ms ≤ 80ms
24V 50..60Hz ≤ 12mA ≤ 30ms ≤ 80ms
110-240 C35 / AC ..... V
110-240 C36 / AC ..... V
24-48 C35 / UC ..... V
24 C36 / UC ..... V
15A /1s ≤ 0,2V ≤100 A ≤ 70A /150 s
15A /1s ≤ 0,2V ≤100 A ≤ 70A /150 s
110-240V 40..60Hz ≤ 5mA ≤ 30ms ≤ 30ms
110-240V 40..60Hz ≤ 5mA ≤ 30ms ≤ 30ms
24-48V 40..400Hz ≤ 6mA ≤ 20ms ≤ 30ms
24-48, 110-240 C37 / UC ..... V
24-48V 40..400Hz ≤ 6mA ≤ 20ms ≤ 30ms
24-48, 110-240 C38 / UC ..... V
System socket C11A *) 5
3
4
22
14
12
Economy socket EC-11
3
7
5
3
4
24
22
14
12
10 A 10 A 400 V 300 V Listed
10 A 400 V
04
4
8 32
EC-11
5
75
SWISS
6
7 8 9
9 34
02
7 24
30
8 32
10A 250VA
9 34
Clip HF-32
11
10A 400VA
1
CONNECTOR
C-A2
C-A2
Ordering example SD -1W
Relay C37/UC110-240V Socket EC-11 or C11A Retaining clip HF-32 (option)
40
KAT 2008
A2
10
31
21
11
A1
11
6
1
2
38
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
4
20
*) with plugged-in neutral conductor connector C-A2 (standard delivery).
Clip HF-32
32
2
10
C11A
A2
31
21
11
A1
10
11
6
1
2
38
4
22
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
4
1
relay
KA108 /DC12-24 V D
35,5
1
2 kV
+ 8
7
30 mA ... 0,8 A AC 20-265 V A
WH: Geh.R: 22 x 28 Geh.B: 22 x 65
3
KA115 / UC12- 24 V U
R
01
• 1- and 2-channel • crossover switching • each channel indicated by LED • Triggering/Output 2kV Tamb. operation/storage: -25..+60/ - 40..+85°C
MAX MIN
and others:
www.comat.ch
8
relay
Case
1
2 kV
+
7
1
L1
+ 8
1
3
2
2 kV
+ 6
5
7
relay
Case
Case
KA 208 / DC12- 24 V D
B
KA115
KA108 AC Solid-State Relay
2 L1
L1
L1
TATE SOLID - S
30 mA ..0,8 A AC 20-265 V A
30 mA ..1,5A AC 20-265 V A
3
B
KA208
Universal AC Solid-State Relay
Universal AC Solid-State Relay
Universal AC Solid-State Relay
1-channel, 0,8A/AC240V. Triac output with RC wiring protection. DC Triggering 12...30V galvanically isolated.
1-channel, 1,5A/AC240V. Triac output with RC wiring protection. Triggering galvanically isolated.
2-channel, 0,8A/AC240V (2x0,5A). Triac outputs RC wiring protection. Width per channel: 11mm. Triggering galvanically isolated.
0,8 A
1,5 A
0,8 A
20 ... 265 V A
30mA
Connection No. on socket ➞
3
Designation according to DIN/EN 50011 ➞
3
1
14
13
Connection with socket CS-18 A2 8
20 ... 265 V A
30mA
14
1
13
2kV
+ A1 7
+ A1 7
8
20 ... 265 V A
30mA
2kV
A2
Industrial Relays
AC Solid-State Relay 2x
01
KA Solid-State
AC Solid-State Relay 1x
01
AC Solid-State Relay 1x
4 14
2
2 3 13 1 14
1
2
2kV 1
2kV
2
+ A2 8
1 13
+
A1 A2 6 5
2
1 A1
7
Data at Tamb. =20°C
Peak inrush power Residual current Frequency range Voltage drop
8A (20ms) 3mA 50/60Hz ≤ 1,5V
20A (20ms) 3mA 50/60Hz ≤ 1,5V
8A (20ms) 3mA 50/60Hz ≤ 1,5V
Control voltage Triggering OFF Switching delay Control current
DC10...30Vd U A1: 6V 12ms 10mA (24V)
UC10...30Vu U A1: 6V 12ms 10mA (24V)
DC10...30Vd U A1: 6V 12ms 10mA (24V)
DC ≤ 20%
KA208/DC12-24V
KA108/DC12-24V
UC KA115/UC12-24V
A40-400 Hz /
Socket for printed circuit mounting S7-P
1
Clip GC-T *)
B
2
1
4
3
6
5
8
CS-18
75
22 x 65
7
Clip RC-G
10
Case
24 22 14 12
2
1
4
3
Case
6
R
8
5
S7- P
7
RC-G
1
2
3
4
5
6
7
8
0,6
3
0,5 x 2
2
30
4
7,25 5,9 4,7
System socket CS-18
ø 2,2
22 x 28 22,5
5,2
13,1
14,5
Ordering example Relay KA115/UC12-24V Socket CS-18 or S7-P Retaining clip RC-W (option)
Clip GC-W *)
View on solder side
21 11
8A2 6B1 5 7A1
22,5
3
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
22
35,5
*) Standard delivery with relay (Case B)
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
41
KAT 2008
DC Solid-State Relay 1x
DC Solid-State Relay 3x
01
KD Solid-State
DC Solid-State Relay 2x
PNP K 2,5 / 3 x1,5 A
5k
+
8
Case
Tamb. operation/storage: -25..+60/-40..+85°C
MAX MIN
and others:
www.comat.ch
1
8
7
1
5k
5k
3
1
relay
Case
R
1
3
2
+
6
3
6 + 5 + 7
5k
+
8
RL
2
Case
KD 315 / DC12- 24 V D
B
KD315
Solid-State Relay like KD125, but 2-channel
Solid-State Relay like KD125, but 3-channel
2,5A/DC24V With thermal overload protection and short-circuit resistent.
2,5A/2x1,5A/DC24V. Width per channel: 11mm. With thermal overload protection and short-circuit resistent.
2,5A/3x1,5A/DC24V. Width per channel: 7,3mm. With thermal overload protection and short-circuit resistent.
2,5 A 10 ... 32 V D
1,5 A 10 ... 32 V D
1,5 A 10 ... 32 V D
1mA 5V
1mA 5V
1mA 5V
Connection No. on socket ➞
4 3
Designation according to DIN/EN 50011 ➞
1
2
01
Short-circuit proof universal DC solid-state Relay 1-channel
• 1- and 3-channel • overload/short-circuit proof K • limiting inductive voltage • each channel indicated by LED • Triggering/Output 2kV
2
RL
4
2
KD215
KD125 AC Solid-State Relay
RL
4
R
02
35,5
7
+
PNP K 2,5 / 2 x1,5 A
1
relay
RL
4
KD 215 / DC12-24 V D
+
PNP K 2,5 A
relay
WH: Geh.R: 22 x 28 Geh.B: 22 x 65
KD125 /DC12-24 V D
+
4 2 14 2 13
1 13
+ 14
+
K
Connection with socket CS-18
K
1 13
1
3
K
K
+
K
2
1
+
A2 8
A1 7
+
A1 6
2
3 13
2
1 13
1
K
3
5k
5k
A2 8
4 2 14 2 13
1
5k
+
+
A2 8
1 A1
7
A1 6
2
5k
+
A1 5
3
+
1 A1
7
Data at Tamb. =20°C
Output Current peak Residual current ON-resistance
1PNP (noc) 15A (20ms) <100 A 50m
2x1PNP (noc) 15A (20ms) <100 A 50m
3x1PNP (noc) 15A (20ms) <100 A 50m
Control voltage Triggering OFF ON-OFF-switching delay Control current
DC 5...18V/10...32Vd U A1-2: ≤ 3V/≤ 6V 2,5ms 4mA (24V)
DC 10...32Vd U A1-2: ≤ 3V/≤ 6V 2,5ms 4mA (24V)
DC 10...32Vd U A1-2: ≤ 3V/≤ 6V 2,5ms 4mA (24V)
KD215/DC12-24V
KD315/DC12-24V
6-12, 12-24 KD125 / DC ..... V
Socket for printed circuit mounting S7-P
2
3
1
Clip GC-T *)
B
2
1
4
3
6
5
8
CS-18
75
22 x 65
7
Clip RC-G
10
Case
24 22 14 12
2
1
4
3
Case
6
R
8
5
S7- P
7
RC-G
1
2
3
4
5
6
7
8
0,6
4
7,25 5,9 4,7
System socket CS-18
0,5 x 2
≤ 20%
30
DC
ø 2,2
22 x 28 22,5
5,2
13,1
14,5
Ordering example Relay KD215/DC12-24V Socket CS-18 or S7-P Retaining clip RC-G (option)
42
KAT 2008
Clip GC-W *)
View on solder side
21 11
8A2 6B1 5 7A1
22,5
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
3
22
35,5
*) Standard delivery with relay (Case B)
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
DC-Motor Control Relay +
KDM3-24 Solid-State
D ROL AN RS T N O C O TO DC MOT BRAKE
3A,12-24VD
K
Industrial Relays
PNP NPN
WH: 22 x 65
M
4
2
+
Q2
8
6
3 Q3
1
Q1
1
+
E1
01
7
relay
35,5
Case
KDM3-24/DC12-24VD
B
KDM 3-24 Motor Control Relay • For controlling and braking of DC Motors Tamb. operation/storage: -25..+60/-40..+85°C
MAX MIN
and others:
www.comat.ch Connection No. on socket ➞
Interface Module for PLC’s and control systems with one PNP power contact and one NPN brake contact. For DC motor controls with brake function. The contacts are overload- and short circuit protected.
3 A (5A) 24V d 10mA 10V 4
Designation according to DIN/EN 50011 ➞
+
+
2 3 1 Q2 Q3 Q1 K
Connection with socket CS-18
K
8
6
5
4
2
8
6
3
1
Contact type Switching current/voltage Switching power DC1 Peak inrush current Contact resistance Leakage current Trigg. delay/release time Operation voltage active Power consumption Pmax
9-28V 400mW / DC24V
M
7
E1 + 7
Power contact FET PNP 3A (5A) / 10-32V ...100W 20A / 1s <100m <100µA <1ms
Data at Tamb. =20°C
Adjustment braking action
S K
3A,12-24VD
Break contact FET NPN 3A (5A) / 10-32V ...100W 20A / 1s <100m <100µA <1ms
DC ≤ 20%
KDM3-24/DC12-24V
Socket for printed circuit mounting S7-P
System socket CS-18 4
2
3
1
10
Ordering example Interface module KD215/DC12-24V Socket CS-18 or S7-P Retaining clip RC-G (option)
5
8
CS-18
3
6 8
5
S7- P
7
RC-G
1
2
3
4
5
6
7
8
0,6
3
6
1
4
7,25 5,9 4,7
4
65
1
75
2
2
0,5 x 2
Clip GC-T *)
30
24 22 14 12
ø 2,2
7
22,5
Clip GC-W *)
5,2
13,1
14,5
View on solder side
21 11
8A2 6B1 5 7A1
22,5
3
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
22
35,5
*) Clip GC-T + GC-W Standard delivery with KDM
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
43
KAT 2008
Solide-State Changeover Relay KDW3-24 Solide-State
1x co
DIN
ER WITH V O E G CHAN NDUCTOR SEMI CO
+ Q1 Q2 01
3 A, 12-24 VD
+
Q1
Q2
K
K
(+)
()
A1
A2
KDW 3-24 / UC24-240V SWISS MADE BY COMAT
A1 A2
KDW 3-24 Solid-State AC/DC Relay • Change over PNP for all inductive loads • Mounting onto DIN rail TS 35. Test voltage: 2kV Tamb. operation/storage: -25..+60/-40..+85°C
and others:
www.comat.ch
MAX MIN
Interface Module Solidstate relay with 1x CO output PNP for 3A, 24VD. The contacts are overload- and short circuit protected K . LED status display. Galvanical isolated output. This relay is specially recommended as an alternative to electromechanical relays for applications with high switching cycles. Bounce-free switching.
3 A (5A) 24V d 10mA 10V
+
Q2
Q1
+
K K
Connection
+
Q1 Q2
R L2
R L1
A1 A2
A1
A2
Data at Tamp = 20°C
Contact type Switching current / voltage Switching power DC1 Peak inrush current Contact resistance Leakage current Trigg. delay / release time
FET PNP 3A (5A) / 10-32V ...72W (160W) 20A / 20ms <50m <100µA <5ms
Operation voltage active Power consumption Pmax
18-255V AC/DC 3-8mA / <400mW
UC 50/60 Hz /
KDW3-24/UC24-240V
TS 35
75
LABEL
Interface module KDW3-24/UC24-240V
44
KAT 2008
4,2
2,5
Ordering example
17,5
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
5
64
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
DIN
Industrial Relays
CTV, C300 Solid-State
Solid-State Relay Solid-State Relay Solid-State Relay Switching 3x 3x amplifier
1 I-0 = 2 kV
CTV11 1- and 3-channel DC Solid-State Relay • for high switching cycles • galvanical separation 2kV • mounting onto DIN rail TS 35
MAX MIN
and others:
www.comat.ch
Solid-State Relay
Compact 3-channel Solid-State Relay
Compact 3-channel Solid-State Relay
for the switching of DC loads up to 2A/DC 24 V. Outputs, galvanically isolated. Overload and short-circuit proof. Specially suitable for high switching cycles. (PLC and ancillery)
like C301.08 but without galvanic isolation of outputs.
250 mA 5 ... 60 VD
2 A 10 ... 30 VD
2 A 10 ... 30 VD
1mA 10V
1mA 10V
1mA 10V
with galvanically isolated triggering input to control and switch DC loads. 1 channel 250mA/DC5-60V
Tamb. operation/storage: -25..+60/-40..+85°C
C311.08
C301.08
12-65V
4-18V
+ EH
+ EL
E
A2
A2
A2
+ 1A1 + 2 A1 + 3 A1 2kV
2
1
Connection
A2
+ 1A1 + 2 A1 + 3 A1 1
3
2
3
5k
2kV PNP
250mA
K
+
K
K
K
1O
2O
3O
K
K
K
1O
2O
3O
O RL
5-65V
+
+
Data at Tamb. =20°C
Admissible peak current Residual current Voltage drop / ON-rheostat
0,75A (20ms) <100zA <1V
15A (20ms) <100zA 50m
15A (20ms) <100zA 50m
Control voltage (U nom) Ripple Triggering OUT Control current on A1 Swtiching delay
EH 15-60V / EL 5-15V ≤ 10% @10V EL ≤ 2,5V / EH ≤ 5V Typ. 10mA ON 200zs / OFF 400zs
DC24V (10...30V)D ≤ 10% @10V U A1: ≤ 6V 4mA @ 24V 2,5ms
DC24V (10...30V)D ≤ 10% @10V UA1: ≤ 6V 4mA @ 24V 2,5ms
DC ≤ 10%
CTV11/DC5-60V
C301.08/DC24V
C311.08/DC24V
Note on use C300
CTV11
The 3 channels can be connected parallel in any desired arrangement (Imax.=6A). The outputs are self-resetting after thermal overload. Self-resetting after short-circuit (>17A/150zs): Triggering OFF.
LABEL
75
Limit load diagram (resistive load) (A)
t
≤ 2s
5
t on t off Steady load
Ordering example 4,2
17,5
2,5
Solid-state relay C301.08/DC24V
CTV11 5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
64
2
10
50
t on 100 (%)
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
45
KAT 2008
Pulse Shaper CPF11,22 Solid-State
Pulse Shaper 2x
DIN
CPF11 Pulse shaper with timing function To stretch respective to limit control pulses. Suitable for NAMUR sensors respective to analyze fast sequences with high revolutions and short pulses. Tamb. operation/storage: -25..+60/-40..+85°C
CPF22
Single Channel Pulse Shaper
Double Channel Pulse Shaper
• Input reversible (E-E) • Input and output times separately settable • 3 (6) functions to choose • Built-in free wheel diode 1A • LED display for E and O
• Input /output galvanically isolated 4kV • Input and output times separately settable • 2 functions to choose • LED output display for each channel
• Settable functions:
• Settable functions:
K L A
MAX MIN
and others:
www.comat.ch
K A
Settable times: input pulse
output pulse
Settable times: input pulse
≥1/ 5 ms
5 ÷600 ms
≥ 0,5 / 2,5 ms 50 / 200 ms
2 A 15... 32 V d
150 mA 45 V d
2mA 10V
2mA 10V
+
15÷32VD
NAMUR sensor +
+ S PNP
11K 5K6
4K7
K
150mA
CPF
CPF
2S
1E1 1E2 2E1 2E2
4kV
E1
E1
1S
+
E1 E2
3K3
+
15÷32VD
S
PNP
E2
S NAMUR
+ +
15…32V
19…28V
+
Three-wire sensor
output pulse
+
FD
O
+
0,8A
2O
1RL
10÷45VD
RL
PNP
1O
2RL
DC ≤ 10%
CPF11/DC24V
K
CPF22/DC24V
Pulse shaping
L
Pulse shaping retriggerable (subsequ. time operation from 0)
S R
t
S (pulse or continuous contact) ⇒ R on for t S no influence on R and t
S R
t
S (pulse or continuous contact) ⇒ R on for t S on for t = t RESET
A
Off delay
t
S R
S ⇒ R on S OFF ⇒ R off with delay
CPF11
TS 35
75
CPF22
Pulse shaper CPF11/DC24V
46
KAT 2008
4,2
17,5
2,5
Example of order 8 5
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
64
10
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Industrial Relays
Industrial Relays
Miniature Contactors
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
1
Miniature Contactors Recommended application 63A 40A 25A 20A 10A 6A
&
&
10 mA 5 mA 1mA 2 3 +1
RIC20 SOC-6
4
RIC-AUX
SOC-2 RIC25
RIC40
RIC63
twin contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
47
KAT 2008
1 L1
13
3 L2
23
5 L3
33
Additional auxiliary Snap-on contacts
43
1
2 T1
3
13
MAX MIN
and others:
www.comat.ch Continuous terminal No. ➞
Designation according to DIN/EN 50011 ➞
83 NO
5
14
53 NO
63 NO
71NC
81NC
51NC
61NC
71NC
81NC
10A 400Va
4 T2
24
54 NO
44 34 6 T3 14 NO
64 NO
74 NO
SU-440M
O
54 NO
84 NO
64 NO
72 NC
SU-422M
SS-1BM / UC12-48 VU O
82 NC
52 NC
62 NC
72 NC
01
O
A1
SU-404M
0µ47 150Ω
82 NC
A2
SOC-6 -1a
4000V 4000V Test voltage: Tamb. operation/ storage: -20..+60/ - 40..+85°C
73 NO
01
50/60 Hz
ON 20A 400Va
• All contacts with twin interruption • Manual operation • Mechanical status display
63 NO
SOC-6-1a/AC230V 01
E0414 01
53 NO
3-/4-pole Miniature Contactor
RC Modules
A1
13 NO
01
DIN SOC-6 Miniature Contactor
Miniature Contactor
SU-440M
SU-422M
SU-404M
SS-1...
Universal Miniature Contactor
Additional auxiliary contact block
Additional auxiliary contact block
Additional auxiliary contact block
with 3 main contacts 20A and 1 auxiliary contact 10A (signal twin contact). Contact opening > 3mm and test voltage 4000V. Specially suitable for “safely separation” in low voltage circuits.
4 NO contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 8 NO contacts.
2 NO + 2 NC contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 6 NO and 2 NC contacts.
4 NC contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 4 NO and 4 NC contacts.
20 A // 10 A 400 V A
10 A 400 V A
10 A 400 V A
10 A 400 V A
10mA 24V // 1mA 6V
10mA 24V
10mA 24V
10mA 24V
1 3 5 13 A1+ L1 L2 L3 NO 13 23 33 43
53
63
73
83
53
63
71
81
51
61
71
RC Modul to limit overvoltage. Universal version (UC...V U) for AC and DC coils. Snap-on directly onto miniature contactor SOC-6.
81
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
Connection lay out (top/bottom) 14 24 34 44 T1 T2 T3 NO 2 4 6 14 A2
Data at Tamb. =20°C / ≤40°C Main contacts // Auxiliary contact
Contact material Switching power AC1 Switching power AC 3/4 Switching current AC15 Switching power DC1 Switching power DC13 Making-/Breaking capacity Mechanical switching cycles
AgNi 11kW 400V // 4kW 400V 4kW 9A 400V // – 1,9A 400V // 1,5A 400V ...300W 0,3A 220V // 0,1A 220V 90A / 70A eff 20x106
Operation voltage AC 50 Hz / DC Power consumption Typical make/release time
0,8...1,2UN 4,2VA/3W 20ms/15ms
AC 50Hz
DC ≤ 10%
Interlocking unit
54
64
74
84
AgNi 7kW 400V – 1,9A 400V ...300W 0,3A 220V >30A 10x106
24, 230 SOC-6-1a / AC ..... V
54
64
72
82
62
72
AgNi 7kW 400V – 1,9A 400V ...300W 0,3A 220V >30A 10x106
AgNi 7kW 400V – 1,9A 400V ...300W 0,3A 220V >30A 10x106
SU-440M
52
SU-422M
SU-404M
A1
A2
82
Current consumption: at AC24V : 8mA at DC24V : 4mA at AC230V : 12mA at DC220V: 2,5mA Release time SOC-6 with RC module ≤ 45ms
SS-1HM/UC110-240V SS-1BM / UC12-48 V
24 SOC-6-1a / DC ..... V
SR-6
mechanically prevents the simultaneous engagement of two parallel working SOC-6. Type: 01
SR-6 O
O
Interlock Unit
Arrangement
Ordering example
23
5 L3
33
•Auxiliary contact block
13 NO
SS-1...
SOC-6
(2NO + 2NC contacts)
SU-422M RC module SS-1H/UC110-240V Interlocking unit SR-6
48
KAT 2008
2 T1
14
4 T2
24
34
6 T3
SU-4...
SOC-6
44
14 NO
SU-4... SS-1... SR-6
SR-6
A1
43
TS35
3 L2
58
13
50
1 L1
45,4
Miniature contactor SOC-6-1a/AC230V
A2
35 44
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
6
3
53
1
26,2
1
1
57
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Innstallation Contactor SOC-2-1a Industrial Relays
DIN SOC-2 Miniature Contactor Cover sealed
3
5
13
1
3
13
SOC-2-1a /AC230VA
AC1 20A 400VIEC/EN 13KW 02 60947-4 AC3 2,2kW 400V A1 EN 60947-4; IEC1095; VDE 0660
A2
1
L1 T1
4
6
14
AC1 20A 400V/13kW AC3 2,2kW/400V
O
I
A1
3
50Hz
IEC/EN 60947-4
02
AC1 20A 400V/13kW AC3 2,2kW/400V
50Hz
2
2
5
SOC-2-1a/AC230VA
50Hz
SOC-2-1a /AC230VA
1
5
L2
13
O A1
L3
T2
4
2
I
T3
6
4
14
A214
6
R
NTACTO
RE CO MINIATU
A2
1
02
SOC-2-1a 3- + 1-pol. Miniature Contactor • All contacts with twin interruption • Manual operation • Mechanical status display 4000V 4000V
Test voltage:
Tamb. operation/storage: -20..+55/ - 30..+80°C
and others:
www.comat.ch
MAX MIN
Installation Contactor High power relay up to 3x20A 400V and 1 auxiliary twin contact 6A. For installation mounting with cover conform DIN 43880. The cover can be sealed. For general applications and motors up to 2,2kW. Suitable for pilot control signals.
20 A // 6 A 400 V A 10mA 24V // 1mA 6V
Continuous terminal No. ➞
A1 1 3 5 13 L1 L2 L3 NO 13 23 33 43
Designation according to DIN/EN 50011 ➞
Connection lay out (top/bottom) 14 24 34 44 T1 T2 T3 NO 2 4 6 14 A2
Data at Tamb. =20°C / ≤40°C Main contacts // Auxiliary contact
Contact material Switching power AC1 Switching power AC3/4 Switching current DC1 Inrush current
AgNi 13kW 400V 2,2kW 400V 20A 24V / 2A 110V 100A / 2,5ms
Switching current Switching current DC1 Mechanical life time
6A 400V 6A 24V / 0,5A 220V > 3 x 10 6
Coil voltage Coil power Typical make / release time
0,8 - 1,2 U N 32W 20ms /1,5 W < 20ms / < 20ms
Installation contactor SOC-2-1a/AC230V Bestellbeispiel
TS35
Ordering example
24, 230 SOC-2-1a/AC.....V
62,5
50Hz
50
AC
SOC-2
Spare parts Cover sealed SOC-2COV
4,1 4,5
4,75 35
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
45
1
50.5
8
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
49
KAT 2008
DIN RIC Miniature Contactor
Contactor 20 A
Contactor 25 A
2NO or 2NC or 1NO/1NC
Contactor 40 A
4NO or 4NC or 2NO/2NC
Contactor 63 A
4NO or 4NC or 2NO/2NC
AUX Block 2NO or 2NC or 1NO/1NC
4NO or 2NO/2NC
SE!
TS 35
NO NOI
AC/DC Istallation Contactors No noise! • All contacts doublemake/ doublebrake • Mechanical status display Test voltage: 4kV/3 Tamb. operation/storage: -20..+55/ - 30..+80°C
and others:
www.comat.ch
MAX MIN
RIC 20
RIC 25
RIC 40
RIC 63
RIC-AUX
Contactor 20 A
Contactor 25 A
Contactor 40 A
Contactor 63 A
Auxilary
Contactor with 2NO or 2NC or 1NO+1NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactor with 4NO or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactblock with 2NO or 2NC or 1NO+1NC contacts. For signalling and control applications up to 6 A with crown twin contacts. For all RIC contactors.
20 A 400 V A
25 A 400 V A
40 A 400 V A
63 A 400 V A
6 A 400 V A
10mA 24V
10mA 24V
10mA 24V
10mA 24V
5mA 24V
1
A1
3
1
3
A1
5
7
1
3
A1
5
7
1
3
A1
5
7
51
61
Connection lay out (top/bottom) 2
A2
4
2
4
A2
6
8
2
4
A2
6
8
2
4
A2
6
8
52
62
1
A1
R1
1
R1
A1
R3
3
1
R1
A1
R3
3
1
R1
A1
R3
3
51
61
4
2
4
2
R2
A2
R4
4
52
62
2
A2
R2
2
R2
A2
R4
R2
A2
R4
R1
A1
R3
R1 R3
A1
R5 R7
R1 R3
A1
R5 R7
51 61
R2
A2
R4
R2 R4
A2
R6
R8
R2 R4
A2
R6
R8
52 62
Data at Tamb =20°C
Contact material Switching current I TH Switching voltage Switching power AC3 Switching power AC1/AC7a Op Frequenz max. cycle/hr Electrical life cycles AC1
AgNi 20A 400V 1,3kW/230V 4kW/230V 600 2x105
AgNi 25A 400V 2,2kW/400V 16kW/400V 600 2x105
AgSnO2 40A 400V 5,5kW/400V 26kW/400V 120 1x105
AgSnO2 63A 400V 8,5kW/230V 40kW/400V 120 1x105
AgNi 6A 400V – – 600 2x105
Coil voltage range Power consumption Operate / release time typ.
0,85 - 1,1 U N 2,5W 20ms // 20ms
0,85 - 1,1 U N 3W 10ms // 50ms
0,85 - 1,1 U N 5W 20ms // 35ms
0,85 - 1,1 U N 5W 20ms // 35ms
– – – // –
UC A 50/60 Hz / D
UC A 50/60 Hz / D
UC A 50/60 Hz / D
24, 230 RIC25-400/UC ..... V
24, 230 RIC40-400/UC ..... V
24, 230 RIC63-400/UC ..... V
RIC-AUX20
24, 230 RIC20-110/UC ..... V
24, 230 RIC25-220/UC ..... V
24, 230 RIC40-220/UC ..... V
24, 230 RIC63-220/UC ..... V
RIC-AUX11
24, 230 RIC20-020/UC ..... V
24, 230 RIC25-040/UC ..... V
24, 230 RIC40-040/UC ..... V
RIC-AUX02
RIC25-63
RIC25
RIC40 RIC63
RIC-AUX
45
RIC20
Installation contactor RIC25-400/UC230V
*Option Sealing cover Type: RIC-SEAL20 RIC-SEAL25 RIC-SEAL40-63
TS35
Ordering example
85
RIC20
24, 230 RIC20-200/UC ..... V
Aux block RIC-AUX20 Sealing cover RIC-SEAL20
50
KAT 2008
1.5* 17,5
35
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
54.5
8
5
44 ( 45.5* )
16.5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
Time Delay Relays
2
• Time Cubes® • Multifunction Time Delay Modules • Time Delay Relays • Pulse Shapers • Step-on Step-off Relays • Power Relays • Socket • Accessories
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
51
KAT 2008
Shot timing modes
Delay functions
E
On delay
t
A
S R
S R
S ⇒ R on S OFF ⇒ R off with delay
S R
S ⇒ R on with delay (t1) S OFF ⇒ R off with delay (t 2)
N
t2
O
Pulse shaping
S R
S (pulse or continuous contact) ⇒ R on for t S no influence on R and t
Pulse shaping, retrigger. (subsequ. time operation from 0)
t
M
S R
S (pulse or continuous contact) ⇒ R on for t S on for t = t RESET
S R
S OFF ⇒ R on for t S no influence on R and t
Pulse shaping
t
H
S R
S (pulse or continuous contact) ⇒ R after t1 on for t 2 S no influence on R and t
On delay single shot
S R
t2
t
X1
B1
S ⇒ R on/off periodically according to t S OFF ⇒ R off
Blinker, pulse start, trailing pulse
S R
t t t
S ⇒ R on/off periodically according to t S OFF: last pulse = t
Blinker, interval start
S R
S ⇒ R after t on/off periodically according to t S OFF ⇒ R off
S
S⇒
S R
S ⇒ R on. S OFF ⇒ R off and starts t . S ⇒ R restart only after t .
on for t OFF ⇒ on with delay for t S OFF ⇒ off
Restart delay
t
I
Repeat cycle timer, pulse start
S R
t1 t2 t1
S ⇒ R on/off periodically according to t1 and t 2 S OFF ⇒ R off
Repeat cycle timer, interval start
S R
C55,CT1: t2 t1
S ⇒ R after t1 (t2) on/off periodically according to t 2 and t1 S OFF ⇒ R off
Special functions
-
t
S R
t1 t2 t1
Star-delta timer
t
S ⇒ R on for t1 S OFF ⇒ R on for t 2 S OFF off for t1 ⇒ R off
Blinker, pulse start
t t t
P
S ⇒ R after t1 on for t 2 S OFF ⇒ R off
Special functions
Y
S t2 R
Repeat cycle timer
t2
t1
S OFF ⇒ R on for t S on for t ⇒ R off
One shot leading and trailing edge
t t t
On delay single shot
t1
B
B2
Delayed pulse
G
S R
Blinker functions
t
L
S ⇒ R on for t S OFF ⇒ R off (pulse clipping)
One shot trailing edge
t1
Pulse shaping
K
S R
t
On and off delay
t1
One shot leading edge
t
Off delay
t
F
W
S ⇒ R on with delay S OFF ⇒ R off
S
LS
Step-on / Step-off switch
S R
S ⇒ R on/off
Step-switching (staircase lighting timer), with time lapse
t
S R
t
S ⇒ R on and starts t. S on for t ⇒ R off.
Stop /Reset t STOP
S STOP interrupts t
T
(t-addition)
resets t t RESET tS RESET restarts immediately
S = Triggering R = Output circuit ⇒ = switches...
t is stopped ⇒ R on/off Test
ON
OFF
Pulse sequence monitoring S1/ S2 P (tP)
U tA
tV
R
: Pulse separation is smaller than the time tP : Pulse separation is larger than the time tP
52
KAT 2008
S1/ S2 P (tP)
V tA Start with S1 = without start-up short-out tA Start with S2 = with start-up short-out tA
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
S1/S2 = Monitoring start P = Pulse sequence tP = Pulse separation
R tV = settable alarm delay (tA = tV)
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
왕 왖
DIN Time Delay Relays
1)
alternatively with instantaneous contact 쮿 without auxiliary voltage (relay bistable) 쏔 without auxiliary voltage (relay monostable)
왕 t 2 = t1 왖 t 2 = 0,5s
Special devices from page 89
L
M
쐌
쮿
쐌 쐌 쐌 쐌 쐌 쐌 쐌
P
S
LS X1
U
V
왖 왖
쐌 쐌 쐌
쐌
쐌 쐌 쐌 쐌
쐌 쐌 쐌
A
F
쐌 쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌
N
Q
쐌 쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌
W
왖 왖
쐌 쐌 쐌 쐌
60*
쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌
M
B
B1 B2 G
CRE1 CRA1 AE2 AE2M AA2 AA2M CY1 CRV1 CRV2 CSV2 CRV3 CRT3 AM1 AM2 AM3 1) CIM1 CM1 CM1L CM2 CM3 CNR1 CT1 CT1L ECO31 ECO32 CPF11 CPF22
쐌 쐌 쐌
A
60* 60* 60*
쐌 쐌 쐌 쐌
쐌 쐌
쐌 쐌
H
쐌 쐌 쐌 쐌
쐌 쐌
I
P
S
LS
Y
U
V
쐌
F
쐌
60 60 60
쐌
쐌
Q
쐌 쐌
15 2x15 2x15 15
쐌 1,5
쐌
L
M
B
B1 B2 G
H
I
P
S
LS
쐌 쐌
쐌
쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌
쮿
쮿
쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
쐌
74 74 74 75 75 75 76 76 76 77 77 77 78 78 78 79 79 80 80 90 90
2x999
쐌 쐌
K
day Page
990
Y
U
V
30 30
t max. sec
쐌 쐌
min
hrs
day Page
30 30* 1,5 12 1,5 12
쐌
쐌
15 15
0,1
쐌
N
hrs
2x30 30 30 2x30 99,9 99,9 15 999
쐌
쐌 쐌 왕
W
min
100 100 100
쐌
쐌
60/0,1
30 60* 10*
쐌
2x60*
쐌 쐌 쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌
쐌
쐌
쐌 쐌
쐌 쐌
2x60*
60 60 60
쐌 쐌
60 100
쐌
쐌 쐌
쐌 쐌
쐌
61 61 61 61 61 63 63 63 63 67 67 67 67 67 68 68 68 68 69 69 69 70 70 70 70
t max. sec
쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌
60*
20 6 6 60
쐌 쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌
E
60*
쐌 쐌
쏔 쏔
L
day Page
20
쐌 쐌 쐌 쐌
쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌
쐌
K
hrs
30 60
쮿
쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌
min
60* 60*
Ext. Poti
E
t max. sec
쐌 쐌
t-Reset
쐌 쐌 쐌 쐌
I
t-Stop
쮿
H
30 30 30 30 30 30 60*
쐌 쐌 쐌 쐌 쐌 쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌 왕 쐌 쐌 왕 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌
B1 B2 G
쐌
쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 쐌 왕 쐌 쐌 왕 쐌 쐌
쮿
B
Function Type
Example for a delay time of 38h: 1. Set range switch to 60sec 2. Set 38sec on the potentiometer (e.g. check 38sec by chronometer) 3. Set range switch to 60h The delay time now amounts to 38h.
쐌 쐌
K
Ext. Poti
RS 121 RS 121.P RS 121.R RS 122-M RS 122-MH RS 122-H RS 321 RS 521 RS 41 CPX-519 CTI-519 CEA-226 CPX-129 CFG-126 CTI-129 CEA-126 CWR-102 CX 38 CX 39 1) CNS-4 CN 135
The TF60 time setting methode permits short examination of long delay time settings. Elapsing times of hours can be monitored in the sec. range.
Q
Function Type
* TF-60
쐌
N
12 12 60
쐌 12
쐌 쐌 쐌 쐌
12/ 60
60 20
30 12*
0,6 0,2
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
53
82 82 82 82 82 82 82 83 83 83 83 83 84 84 84 84 85 85 85 85 86 86 86 87 87 94 94
KAT 2008
Time Delay Relays
쎲
W
Ext. Poti
CT..-E 30 CT..-A 30 CT..-K 30 CT..-W 30 CT..-B 30 CT30 1) CT32 1) CT33 1) CT36 1) C81 C82 C83 C84 C85 CS1 CS2 CS3 C63 C64 C65 C66 C52 C53 C55 C56
Plug-in Time Delay Relays
F
t-Reset
A
t -Stop
E
t-Reset
Plug-in Time Delay Relays
Function Type
t -Stop
Plug-in Time Cubes and Time Modules pour Industrial Relays
2
Plug-in Time Cubes for Industrial Relays
t
ty p e
Pa ge
Co nta c
et So ck
an ge Tim er
Se rie s
Time Delay Relays
Monofunktions-Timer 5 different timing functions with delay time settings
CT 2
0,2 s-30 min
10 A
61
Monofunktions-Timer 5 different timing functions with delay time settings
CT 3
0,2 s-30 min
10 A
61
CT 30.1
0,25 s-30 min
10 A
63
CT 30.3
0,25 s-30 min
10 A
63
CT 30.5
0,25 s-30 min
0,8 A
63
CT 30.7
0,25 s-30 min
5A
63
CT 32.1
0,15 s-60 min
10 A
63
CT 32.3
0,15 s-60 min
10 A
63
CT 32.5
0,15 s-60 min
0,8 A
63
CT 32.7
0,15 s-60 min
5A
63
CT 33.1
30 ms-60 h
10 A
63
CT 33.3
30 ms-60 h
10 A
63
CT 33.5
30 ms-60 h
0,8 A
63
CT 33.7
30 ms-60 h
5A
63
CT 36.1
2 x 50 ms-60 h
10 A
63
CT 36.3
2 x 50 ms-60 h
10 A
63
CT 36.5
2 x 50 ms-60 h
0,8 A
63
CT 36.7
2 x 50 ms-60 h
5A
63
8-/11- pole plug-in time delay relay system The simplest time delay relay system world-wide, fitting all 8 or 11- pin relay sockets (octal/ submagnalite). Original time cubes ® are simply placed between socket and relay without rewiring. In this way, even as a retrofit, all industrial relays can be provided with the required timing functions without additional space being required. The contact connections of the relay on the socket remain trough-connected.
The Comat CT System
Economy Timer 3 timing functions. Mains controlled. LED indication
Universal Timer 7 timing functions. Mains kontrolled. Flashing LED shows time lapse.
The time delay relays and monitoring relays consist of the plug-in CT time function modul and 11-pole CT output relay and the system socket C12B. Both system components can be combined freely with one another. This allows the equipment to be selected optimally for specific use. Subsequent modifications, for example a change from mechanical contacts to solid-state outputs, are possible at any time by simple reconnection. This provides the user a complete, universal system, the high flexibility of which is unique throughout the world.
54
KAT 2008
Universal Timer 12 functions, mains controlled. Flashing LED shows elapsing time. Increased setting accuracy with 1:5 scale devision.
Universal Repeat Cycle Timer Pulse or interval start. Independent setting of t1/t2. Flashing LED shows time laps.
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
t
ty p e
Pa ge
Co nta c
et So ck
an ge
Economy-Time Delay Relay 2 functions
C81
0,2 s-30 min
8A
67
Economy-Time Delay Relay 4 functions
C82
0,5 s-60 min
8A
67
Universal Multifunctional Time Delay Relay
C83
50 ms-60 h
8A
67
Time Delay Relay, no auxiliary voltage
C84
0,1s-20 min
5A
67
Double Time Delay Relay and Repate Cycle Timer, 6 functions
C85
2x 50 ms-60 h
8A
67
Economy Time Delay Relay 4 functions
CS1
50 ms-60 min
8A
68
Universal Multifunctional Time Delay Relay, 7 functions
CS2
50 ms-60 h
8A
68
Universal Multifunctional Time Delay Relay
CS3
50 ms-60 h
6A
68
Universal Multifunctional Time Delay Relay
C63
50 ms-60 h
6A
68
Time Delay Relay without auxtliary voltage
C64
0,1s-20 min
5A
69
C65 / 66
1- 6 min
6A
69
Universal Multifunctional Time Delay Relay, 2 functions (digital)
C52
0,1s - 60 min
8A
70
Universal Multifunctional Time Delay Relay, 10 functions (digital)
C53
0,1s- 60 h
8A
70
Universal Multifunctional Time Delay Relay, 10 functions (digital)
C53.3
0,1s - 60 h
0,5 A
70
Universal Multifunctional Time Delay Relay, 10 functions (digital)
C53.4
0,1s- 60 h
2A
70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C55
0,01s - 60 days
5A
70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C55 .3
0,01s - 60 days
0,5 A
70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C55 .4
0,01s - 60 days
2A
70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C56
0,01s - 60 days
5A
70
55
KAT 2008
Restart Delay Relay
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
Time Delay Relays
Plug-in Time Delay Relays
Tim er
Se rie s
Time Delay Relays
2
Plug-in Time Delay Relays
t
ty p e
Pa ge
Co nta c
et So ck
an ge Tim er
Se rie s
Time Delay Relays
RS Serie Multifunctional Time Delay Relay, 5 functions
RS121
10 ms -100 h
5A
74
Multifunctional Time Delay Relay, 5 functions
RS121.P
10 ms -100 h
5A
74
Multifunctional Time Delay Relay 5 functions with t-stop- and t-reset-function
RS121.R
10 ms -100 h
5A
74
Universal Cycle Timer
RS122-
0,1s- 30 h
5A
75
Digital Multifunctional Time Delay Relay, 5 functions
RS 321
10 ms - 99,9 h
5A
76
Digital Multifunctional Time Delay Relay with digital display of elapsing time, 5 functions
RS 521
10 ms - 99,9 h
5A
76
Economy Multifunctional Time Delay Relay, 5 functions
RS 41-M
0,1s -15 min
6A
76
CPX 519 0,01s -999 min
6A
77
Digital Cycle Timer
CTI 519
2x 0,01s - 999 min
6A
77
Digital Multifunctional Time Delay Relay, 2 functions
CEA-226
0,1s -990 min
6A
77
Multifunctional Time Delay Relay, 5 functions
CPX 129
0,1s -15 h
6A
78
Time Delay Relay with 3 double functions (t1/ t2 individual)
CFG 126
2 x 0,1s-5 min
6A
78
Cycle Timer
CTI 129
2 x 0,1s -15 h
6A
78
Multifunctional Time Delay Relay, 2 functions
CEA-126
0,1s -15 min
6A
79
Single Shot Relay 3 functions
CWR-102
0,1-1,5 s
6A
79
Multifunctional Time Delay Relay 3 functions
CX 38
2 x 0,1s -15 h
6A
80
Star-delta Timer ON.. with instantaneous contact
CX 39
1-100 ms 0,1s -15 h
6A
80
C Serie Digital Multifunctional Time Delay Relay with digital display of elapsing time, 5 functions
CX Serie
56
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
idt Co h nta ct
Pa ge
e ra lw Ov
an ge
Mono function Time Delay Relay Economy Time Delay Relay ON-Delay
CRE1
0,5 s- 30 min
13
6A
82
Economy Time Delay Relay OFF-Delay
CRA1
0,3 s- 30 min
13
6A
82
Mono function Economy Time Delay Relay
AE2
0,8 s -12 min
17,5
10 A
82
Mono function Economy Time Delay Relay
AA2
0,8 s -12 min
17,5
10 A
82
Star-Delta Time Delay Relay
CY1
0,5 - 60 s
17,5
6A
82
2
Extra slim 13 mm Multifunctional Time Delay Relay 3 functions
CRV1
0,5 s- 30 min
13
6A
83
Universal Time Delay Relay 3 functions
CRV 2
50 ms- 60 h
13
6A
83
Universal Time Delay Relay 7 functions
CSV 2
8 ms-10 h
13
1,5 A
83
Double Time Delay Relay
CRV 3
50 ms- 60 h
13
6A
83
Universal Repeat Cycle Timer
CRT 3
50 ms- 60 h
13
6A
83
Economy Time Delay Relay 4 functions
AM1
0,5 s- 60 min
17,5
10 A
84
Universal Time Delay Relay 4 functions
AM 2
0,5 s- 60 min
17,5
10 A
84
Universal Time Delay Relay with instantaneous contact, 4 functions
AM 3
0,5 s- 60 min
35
10 A
84
Universal Function Relay with 9 functions including Staircase Lighting Timer
CIM1
0,6 s- 60 h
17,5
16 A
84
Universal Time Delay Relay 4 functions
CM1
50 ms -12 h
17,5
6A
85
Universal Time Delay Relay, 4 functions with external potentiometer and t Stop/ t Reset input
CM 2
0,3 s-12 h
35
6A
85
Universal Time Delay Relay, 7 functions Service ON/OFF
CM 3
50 ms - 60 h
17,5
6A
85
Time Delay Relay, no auxiliary voltage
CNR1
0,1s -12 min
17,5
5A
86
CT1
0,1s - 30 h
17,5
6A
86
Economy Time Delay Relay 3 functions
ECO 31
0,5 s- 20 min
22,5
6A
87
Multifunctional Time Delay Relay 6 functions
ECO 32
0,1s -12 h
22,5
6A
87
57
KAT 2008
DIN A (Installation distribution panel)
DIN C (Industry)
Universal Repeat Cycle Timer
22,5mm mounting series
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
DIN Time Delay Relays
Tim er
Se rie s
Time Delay Relays
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
Specially Time Delay Relays
Amplifier Relays
t Pa ge
Co nta c
ty p e et
0,1s - 30 min
DIN 35
4 x 6A
90
Multifunctional Time Delay Relay 2 functions, external potentiometer
CN 135
0,1s - 30 min
DIN 35
8A
90
Universal Timer Module for PCB mounting 5 functions
CU 23
0,01s-300 min
32 x PNP 120 mA 32 mm NPN 150 mA
90
Amplifier Relay, Switching Amplifier
SFR1
Amplifier for 3 wire and Namur Sensors. Potential free contacts.
5A
92
Amplifier Relay, Switching Amplifier
SFR2
Amplifier for 3 wire and Namur Sensors. Potential free contacts.
6A
92
SBV11 For direction indication blinkers in vehiles. High life expectancy.
10 A DC
93
SSV11 For high switching numbers.
10 A DC
93
Single Channel Pulse Shaper 4 functions
CPF 11
5 - 600 ms
DIN 17,5
PNP DC 0,8 A
94
Double Channel Pulse Shaper 4 functions
CPF 22
50 / 200 ms
DIN 17,5
2 x DC 150mA
94
Preset Counters
KAT 2008
So ck
CNS-4
Switching Amplifier
58
an ge
Cascade Relay
Amplifier Blinker
Pulse Shapers
Tim er
Se rie s
Time Delay Relays
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
Preset Counters 3 functions
CCX 350 Switching after the preset number of pulses are reached, max. 999
6A
95
Preset Counters with display 3 functions
CCX 550 Switching after the preset number of pulses are reached, max. 999
6A
95
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays Time Delay Relays
Plug-in Time Cubes and Time Delay Modules
2
Time Cubes® : CT2 and CT3
CT-System: CT30, CT32, CT33, CT36
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
59
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
60
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Plug-in Time Cubes
11
PLUGE SIMPLY N BETWEE 0,2 s - 30 min
0,2 s - 30 min
0,2-3s/min • 2-30s/min
0,2-3s/min • 2-30s/min
D
Time Delay Relays
CT2 /CT3 Time Cubes
8
On delay
Industrial relay Time cube ®
CT2 (8-pin) 8- /11-pole Plug-in Time Delay Relay System
RELAY
CT2 7
2
A2 7
A1 2
S B1
+
Socket
CT3 10
<
A2 10
A1 2
Triggering
E
CT .. - E 30 / ...
A
CT .. - A 30 / ... CT .. - K 30 / ...
H
DC9,5-18V
UC20-65V
UC90-265V
2 = 8 - pole 3 =11- pole
Function
S ⇒ R on for t S OFF ⇒ R off (pulse clipping) UC90-150V
Order no.
L
S
U M
L
S
U M
L
S
Pulse shaping
K
+
S
Blinker, pulse start
+
K
UC AC/DC
DC 10%
W
W
CT.. -W30 / ...
H
L
S
B
CT .. - B 30 / ...
H
L
S
S ⇒ R on/off periodically according to t S OFF ⇒ R off
ON
Industrial relay
Socket
EC-8
Ordering example
EC-11
6
5
4
3
9
8
7
5
3
4
24
22
12
14
34
32
24
22
14
12
EC-8
EC-11
10 A 10 A 400 V 300 V Listed
10 A 10 A 400 V 300 V Listed
10 A 400 V
62
10 A 400 V
Time cubes CT2-E30/H Socket EC-8 or CS-8
S = Triggering R = Output circuit ⇒ = switches...
OFF
02
CT2 / 3
S R
t t t
B
02
S
t
Clip
32
Relay C2-... Time cubes CT3-E30/H Sockel EC-11 oder C11A
30
S
S R
S (pulse or continuous contact) ⇒ R on for t S no influence on R and t
A2 A1 A2 B1 A1 A2 B1 A1 +
t
One shot leading edge S W t R
+
10A 250 V A
MAX
S R
S ⇒ R on S OFF ⇒ R off with delay
S B1
Socket
UC180-265V
and others:
41 3 567 8 11 9
413 586
A
All new types ..30 (0,2s-30min) are fully compatible with all previous types ..20, ..21 and ..25.
www.comat.ch
Off delay
4 1 3 5 6 7 8 119
413 58 6
2
S ⇒ R on with delay S OFF ⇒ R off
CT3 (11-pin) RELAY
The simplest time delay relay sys-tem world-wide, fitting all 8 or 11-pin relay sockets (octal/sub-magnalite). Original time cubes ® are simply placed between socket and relay without rewiring. In this way, even as a retrofit, all industrial relays can be provided with the required timing functions without additional space being required. The contact connections of the relay on the socket remain through-connected.
S R
t
E
S3-CT For Relay C2...C3
Relay C3-...
HF-33 For Relay* C21...C39
58 ( 51* )
25
22
4
A2
21
11
A1
A2
31
21
11
A1
7
8
1
2
10
11
6
1
2
38
38
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
61
KAT 2008
CT-System
Multifunction Time Delay Relays, Modular
11
The Comat CT System is modular. The time delay relays and monitoring relays consist of the plug-in CT electronic module and an 11-pole CT output relay. Both system components can be combined freely with one another. This allows the equipment to be selected optimally for specific use. Subsequent modifications, for example a change from mechanical contacts to solid-state outputs, are possible at any time by simple reconnection. This provides the user a complete, universal system, the high flexibility of which is unique throughout the world.
RELAYS MODULE
The system socket C12B0 serves as a basis for the vibration-free reception of the electronic module. It has a 4-pole module slot in which the CTmodule –also without output relay– locks in such a way that it is vibration-free. Contact is via twin knife contacts which ensure optimal contact reliability. With the A2-connector C-A2 plug-in flush in the socket, the neutral conductor (N / –) can be connected as a 10A bus from socket to socket. This considerably reduces wiring work. Robust terminals for cross-sections up to 4mm2 and generous labelling facilities are other advantages of this practical comat system socket. As variants to the standard socket C12B0, two identical sockets, but with printed device diagram, are available (C12B1/2). By clearly identifying the connections, these sockets ensure rapid, error-free and therefore economical wiring. When a service is required, they faciliate fault location. The CT module demonstrates comat's practical experience in the area of industrial electronics. All control and display elements are arranged on the front and are labelled in a selfexplanatory manner for international use. The values set are also clearly legible when the module has been installed. Printed diagrams explain the functions, and the connection scheme directly indicates the appropriate terminals in the system socket. A transparent front cover provides protection from unauthorized misadjustment and additionally locks the module onto the output relay. Triggering is performed with the operating voltage (L1or +). Hence, no potential-free contacts are required. Triggering complies with the machine standards. A parallel connection of other users to B1 is admissible. The 2 voltage ranges UC110-240V and UC24-48V have been chosen by comat to ensure a high level of reliability in triggering. They permit use with an AC or DC supply and optimal adaptation to the operating conditions of modern controls. In case of an even broader voltage range, e.g. 24-240V it is often possible to achieve only currents of a few 100µA in the trigger circuit B1 with simultaneous low threshold voltages to less than 20V. This may lead to unintentional triggering due to capacitive/inductive pickups, or faulty switching may occur owing to sufficiently loaded control contacts. During operation, 50V are readily measured on open-ended lines.
The consumption of the CT modules comes to less than 1W. The output relays have the complete device diagram, the performance data and the complete order no. on the front, supported by a colour code, which indicates an AC coil with red and a DC coil with blue. The .1 and .2 relays have a safety manual operation facility as a standard feature, which switches the contacts only after a lock has been released (twohand principle). The standard contacts .1 and .3 have proved their worth millions of times in heavy current applications. The contact material AgNi permits a large switching range and thanks to generous dimensioning achieves a high number of cycles. With its high breaking capacity of up to 10A/400V, this contact is a reliable allround contact for use both in mains circuits and in the lower voltage range from 12V/10mA. The twin contacts .2 and .4 switch every circuit with two independent reeds. Compared with single contacts, they provide up to 100 times greater safety with regard to the level of possible faulty switchings. In spite of their high breaking capacity of up to 6A/250V, these contacts are particularly suitable for low switching currents and switching voltages down to 1mA/6V. The solid-state relays are used instead of mechanical contacts. In the standard version .5, the relay has a potential-free output which switches an AC or DC load in the same way as a mechanical contact. However, it functions without bounce or wear, withstands overloads, has shortcircuit protection and has a practically unlimited life even with full output load. Preferred applications are high switching frequency, for example as repeat cycle timers, flashing bars with bulb load or extreme inductive loads, for example large solenoid valves, couplings, motors, etc. An additional protective wiring of the output or of the load is not necessary in these comat relays for any application. They are completely insensitive in an aggressive atmosphere, for example in the chemical industry, in waste water treatment plants, etc.
Triggering and otheres: www.comat.ch
A2 A1 A2 B1 A1 A2 B1 A1 S
S
Timer module
+
Function /triggering
Time range
E W B
Economy timer
CT30
S
+
+
0,25 s - 30 min 0,25-3s... 2,5-30min
3 functions, voltage controlled, output LED. Seismic approved.
Universal timer
E
0,15 s - 60 min
7 functions, voltage controlled, time lapse display, blinking. Seismic approved.
A N K B1 W B
0,15-1,5s... 6-60min ★
Universal timer
E
30 ms - 60 h
12 functions, voltage controlled, time lapse display, blinking, high setting accuracy by dial graduation 1:5.
A N L F K G B1
30-150ms... 12-60h ★
CT32
CT33
W H B
I P
Universal repeat cycle timer
CT36
2x 50 ms - 60 h 2x 50-600ms... 5-60h ★
Pulse or pause start. t1/ t2 separately settable. Time lapse display t1/ t2.
F O
t2= t1
E
G H
t2=0,5s
★ TF60 setting (page ✹)
Triggering
Function (page ✹)
Note on use
L
According to the standards «Safety of machines» e.g. EN 60 204-1, EN 292-2, triggering with A2potential (N / –) is only admissible in exceptional cirumstances. For that reason the comat CT modules are triggered by A1-potential (L / +). This makes them unrestrictedly suitable also for use in machines and systems which must conform with machine or CE guidelines or directives.
(+) S a)
A1 B1 A2
N
( ) a) A parallel load at B1 is admissible on all CT30 modules.
Order no. for individual module (without output relay): UC110 - 240 V
UC115 V, UC 230 V
UC115 V, UC 230 V
UC110 - 240 V
UC 24 - 48 V
UC 24 - 48 V
UC 24 - 48 V
UC 24 - 48 V
CT30 / .... V
CT32 / .... V
CT33 / .... V
CT36 / .... V
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
62
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
11
CT-System
Time Delay Relay assembled (module + output relay) Solid-state outputs
Contact outputs
2x
.1 MAX
.3
RELAY: C31L /...
.5
RELAY: C33/...
2x1 changeover cont.
Solid-state output
Solid-state output
10A 250 VA 1)
(with instantan.contact) 10A 250 VA 2)
for AC or DC load 0,8A 10-265 VU
for DC load 5 A 10-30 VD
9 8 7 5 3 4
38 36 28 26 18 16
14 12 Y2 Y3 18 16 28 26
1) MODULE
R2
R1 25 MODULE
Order no.
Order no.
5
2)
UC
50/60 Hz
AC/DC
9
8
7 5 3
+
10 11 6 12 1 2
10 11 6 12 1 2
10
11
6
1
R
MODULE
MODULE A2
B1 A1
A2
12 2
10
+
B1 A1 11
6
1
12 2
+
+ Order no. for module + ouput relay (delivery unit):
AC 24, 48,115, 230 V
AC 24, 48,115, 230 V
AC110-240 V
UC110-240 V
DC 24, 48,110, 220 V
DC 24, 48,110 V
UC 24-48 V
UC 24-48 V
CT30.1 / .... V
CT30.3 / .... V
CT30.5 / .... V
CT30.7 / .... V
AC 24, 48,115, 230 V
AC 24, 48,115, 230 V
AC115, 230 V
UC115, 230 V
DC 24, 48,110, 220 V
DC 24, 48,110 V
UC 24-48 V
UC 24-48 V
CT32.1 / .... V
CT32.3 / .... V
CT32.5 / .... V
CT32.7 / .... V
AC 24, 48,115, 230 V
AC 24, 48,115, 230 V
AC115, 230 V
UC115, 230 V
DC 24, 48,110, 220 V
DC 24, 48,110 V
UC 24-48 V
UC 24-48 V
CT33.1 / .... V
CT33.3 / .... V
CT33.5 / .... V
CT33.7 / .... V
AC 24, 48,115, 230 V
AC 24, 48,115, 230 V
AC110-240 V
UC110-240 V
DC 24, 48,110, 220 V
DC 24, 48,110 V
UC 24-48 V
UC 24-48 V
CT36.1 / .... V
CT36.3 / .... V
CT36.5 / .... V
CT36.7 / .... V Please refer to chapter Industrial Relays for relay datas.
System socket C12B0 Figure: with plug-in neutral conductor connector C-A2
DC 10%
2 4
O
K
K
A Jumper 5-7 : R2 = R1 B Jumper 6-12 : R2 = S
AC
3 4 17 18
Order no. for module + ouput relay (delivery unit):
Order no.
7
RL
+
R
A2 11 Y1 B1 15 A1
B
8
9
A2 35 25 B1 15 A1
+
RL
+
9 8 7 5 3 4
R
Order no.
RELAY: C37/...
3 changeover cont.
A
and otheres: www.comat.ch
.7
RELAY: C35/...
Time Delay Relays
MODUL
RELAY
1) Same relay, but with twin contacts 6A 250V A order no. CT.. .2 /...V 2) Same relay, but with twin contacts 5A 250V A order no. CT.. .4 /...V
The Time Relays CT30.., CT32.., CT33.. and CT36.. consist of modules (incl. cover) and output relays. The socket has to be ordered seperatly.
5)
3) To module CT30 (Relay without output LED) 4) To module CT32 ÷ 36 (L= Relay with output LED)
The modules can also be combined with other Comat relays. In this case the relays and the modules have to be ordered seperatly.
5) For relay C3... (instead of C31/32, or CT...1/.2): Retaining clip S3-C Front cover FS-R
Please refer to chapter industrial relays for datas.. Order no. for individual ouput relay (without module): Ordering example Timer CT32.1/AC230V Socket C12B0
AC24,48,115,230V
AC24,48,115,230V
AC110-240V
DC24,48,110,220V
DC24,48,110,220V
UC24-48V
C31/ ...V 3)
C31L / ...V 4)
C33 / ....V
C35 / ....V
UC110-240V UC24-48V C37 / ....V
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
63
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
64
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
Time Delay Relays
Plug-in Time Delay Relays
2
• Multifunction Time Delay Relays • Restart Delay Relays
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
65
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
66
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Multifunctional Time Delay Relays
L ONES A C I T C A THE PR
Time Delay Relays
C80
and otheres: www.comat.ch
C81
C82
C83
C84
2
C85
22,5 mm Plug-in Time Delay Relay System
Economy Time Delay Relay
Economy Time Delay Relay
Universal Multifunctional Time Delay Relay
Time Delay Relay, no auxiliary voltage
Double Time Delay Relay and Repeat Cycle Timer
for all delay, shot timing and blinking functions. Double functions, repeat cycle timing and functions without auxiliary voltage.
on delay or blinking, voltage controlled, output-LED.
on delay, off delay, one shot leading edge, pulse shaping K, voltage controlled, output-LED.
• 12 functions + ON(Test), voltage controlled. • Time lapse display (double blinking= t2) • Input-LED (24-240V) • Output-LED • Seismc approved.
• Off delay • One shot trailing edge • Triggering display • Minimum triggering time 150ms only • Seismc approved.
• 6 functions + test • t1/ t 2 separately settable • Time lapse display (double blinking= t2) • Input-LED (24-240V) • Ouput-LED • Seismc approved.
E
E
A N
E
E B2
Triggering
Function (page ✹)
A K
W H B
A N L F K G B1 O
W
I P
no auxiliary voltage
F O G
H
Time range
0,2 s - 30 min
0,5 s - 60 min
50 ms - 60 h ★
0,1s -20 min
★ TF60 setting (page ✹)
2 x 50 ms - 60 h ★
0,2-3s...2-30min
0,5-6s...5-60min
50-600ms...5-60h
0,1-1,2s...1,7-20min
2 x 50-600ms...5-60h
8 A 250 V A
8 A 250 V A
8 A 250 V A
5 A 250 V A
8 A 250 V A
MAX
Triggering 4
3 1
2
4
2
18 16
3 1
4
2
3 1
4
18 16
18 16
S
+
S
+
S
+
2 3
1
2
3 1
R R
R
15 A1
A2 B1 15 A1
A2 B1 15 A1
A2 25 17 A1
A2 B1 15 A1
5 7
8 6 5 7
8 6 5 7
8 6 5 7
8 6 5 7
R A2
8
6
+
R
+
+
AC 50/60 Hz
AC110 - 240 V
AC110 - 240 V
UC AC/DC
UC 24 - 48 V
UC 24 - 48 V
+
AC 230 V
C 81 / .... V
C 82 / .... V
4
2
3
UC 24 - 48 V
UC 24 V
F O
C 84 / .... V
C 85 / .... V
G H
t2=0,5s
3 5
C 83, 84, 85
C 81 C 82
75
1
4
CS-18
UC 24 - 240 V
UC 24 V
1
2
8
UC110 - 240 V
t2= t1
24 22 14 12
6
AC115 V
UC 24 - 240 V
C 83 / .... V
System socket CS-18 Figure: with inserted retaining clips (standard delivery with relay)
+ AC 230 V
AC115 V
Ordering no.
4
18 16
26 18
A2 A1 A2 B1 A1 A2 B1 A1
7
8 7 67
Ordering example Timer C83/ UC24-240V Socket CS18
21 11
8A2 6B1 5 7A1
22,5
4
22
36
68
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
67
KAT 2008
11
CS, C60
Multifunctional Time Delay Relays
LTIS
THE MU
and otheres: www.comat.ch
CS1
CS2
CS 3 (2nd contact: 6 - 5 -7)
C63 (2nd contact: 1- 4 - 3)
11- pole Plug-in Time Delay Relay System
Economy Time Delay and Blinker Relay
Universal Multifunctional Time Delay Relay
Universal Multifunctional Time Delay Relay
Universal Multifunctional Time Delay Relay
for all delay, short timing and blinking functions from 50ms up to 60 hours. CS1, CS2 with connection for remote potentiometer. Front panel mounting with FZ-50.
With additional connection for remote potentiometer SP-01/1M (up to 50m).
like CS1, but with 7 functions and delay times up to 60 hours.
like CS2, but with 2nd contact instead of Z1-Z2 (terminal 6-5-7).
like CS3, but with 2nd contact on terminal 1-4-3.
Replaces fully compatible CSE2, CSB2
Replaces fully compatible CSA2,CSK2,CSN2
Replaces fully compatible CSE3, CSA3
Replaces fully compatible CX35, CX36
E
E W B B2
E W B B2
E W B B2
A K N
A K N
A K N
50 ms - 60 min ★
50 ms - 60 h ★
50 ms - 60 h ★
50-600ms...5-60min
50-600ms...5-60h
50-600ms...5-60h
50 ms - 60 h ★ 50-600ms...5-60h
8 A 250 V A
8 A 250 V A
6 A 250 V A
6 A 250 V A
EXT POT
EXT POT
E W B B2
Triggering
Function (page ✹)
Time range
★ TF60 setting (page ✹) MAX
Triggering
9 8 7 5
3
4
2nd contact: 6-5-7
9 8 7 5 3
4
18 16 Z2 Z1 B1
18 16 Z2 Z1
9 8 7 5 3
4
18 16 28 26 B1
2nd contact: 1-4-3
9 8 7
3 4
5
28 26 B1
18 16
A2 A1 A2 B1 A1 S
R
S
+
+
Z1
10 11
6
A1
A2 15
Z1 B1 A1
A2 15
25 B1 A1
A2 25 B1
15 A1
2
10 11
6 1 2
10 11
6 1 2
10 11 6
1 2
1
+
UC AC/DC
Ordering no.
R
R
R
A2 15
+
+
+
+
UC110 -240 V
UC110-240 V
UC110-240 V
UC110-240 V
UC 24 -60 V
UC 24-60 V
UC 24-60 V
UC 24-60 V
UC12-15V
UC12 -15 V
UC12 -15 V
CS1 / .... V
CS2 / .... V
CS3 / .... V
C63 / .... V
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
EXT POT 1M 1
2 3
max. 50m 7 5/6 Z2 Z1
CS1/ 2
5
Ordering example
4
Timer CS2 / UC110-240 V Socket C11A
6 7
3
8
2
9 1
10
Built-in potentiometer SP-01/1M (page ✹)
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
68
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
11
C65, C66
Restart Delay Relay
S PROCES D E N I F E NO UND NS AFTER IO T I COND TERRUPTION N MAINS I
Time Delay Relays
C64
11
and otheres: www.comat.ch
2
C65 (50Hz) C66 (60Hz)
C64 L
Time Delay Relay without auxiliary voltage True off delay or one shot trailing edge after cut off power supply. Minimum triggering time 150ms only. Seismc approved.
R
Restart Delay Relay The C65 (50Hz) and C66 (60Hz) are special timers with no auxiliary voltage to guarantee a minimum OFF time after removal of supply. After the interruption of supply, the device will not reclose before the set time (1-6mins.) has elapsed,
0-
S CONTACTOR
t C65/66 N
M
3A
even if there has been a new command to switch ON. Typical application: After a mains failure it is not possible to restart (close contacts) before the machine is at rest. Example: Motor (see diagram on the left).
Replaces RS124, CSR2
X1 Function (page ✹)
A N without auxiliary voltage
S
X1
t
Triggering
0,1s -20 min
Time range
1- 6 min
0,1-1,2s...1,7-20min
Partial ranges
1-1,5 ...4-6min
5 A 250 V A
MAX
Do not connect 5-6-7!
9 8
7
5
28 26
S
t
R
R
6 A 250 V A
Triggering
3 4
9 8
18 16
28 26
7
5
3 4 18 16
A2 A1
R
R
A2 25
10 11
15 A1 6
1 2
S
A2 25
+
10 11
15 A1 6
1 2
+ UC110-240 V UC 24-60 V
AC
Ordering no.
C64 / ....V
50 Hz
60 Hz
AC 230 V
AC 230 V
AC115 V
AC115 V
C65 / .... V
C66 / .... V
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
Ordering example Timer C64/UC110-240V Socket C11A
Ordering example Timer C65/AC230V Socket C11A
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
69
KAT 2008
11
C50
Multifunctional Time Delay Relays
STERS
THE MA
and otheres: www.comat.ch
C52
C53
C55
(C53.3, C53.4)
(C55.3, C55.4)
C56
11-pole Plug-in Time Delay Relay System
Universal Multifunctional Time Delay Relay
Universal Multifunctional Time Delay Relay
Universal Multifunctional Time Delay Relay
Universal Multifunctional Time Delay Relay
for all timing modes from 10ms up to 60 days. Extremly accurate due to quartz time base. Digital functions and residual time display. Front panel mounting with FZ-50. Test function .
• 2 functions • 0.1s-60min (quartz) • 1 change-over contact
• • • •
• 15 functions incl. Puls sequence monitoring (U/V) • 0.01s-60 days (quartz) • Setting step up to 60s :1ms • t-STOP and t-RESET input • 2 changeover contacts • Alternatively solid-state output .3 or .4 • Seismic approved)
like type C55, but with potential free triggering of START, STOP and RESET (insulation from 2-10: 2kV).
E W H B I P
E W H B I P
A K N M G F Q
A K N M G F Q
U V
U V
0,1s - 60 h
0,01s - 60 days
0,01s - 60 days
0,1s-60min...0,1min-60h
0,01-60s...0,1h-60days
0,01-60s...0,1h-60days
8 A 250 V A
5 A 250 V A
5 A 250 V A
Partial ranges
8 A 250 V A
STOP
MAX
Triggering 9
8
7
3 4
5
9
8
7
3 4
9 8 7 5 3 4
9 8 7 5 3 4
18 16
28 26 Y1 Y2 18 16
28 26 COM B1 18 Y1
5
18 16
START
0,1s - 60 min
Time range
RESET
E W H B I A K N F O
STOP
E A
+ 10V
Triggering
RESET
E
Function (page ✹)
10 functions 0.1s-60h (quartz) 1 change-over contact Alternatively solid-state output .3 or .4
A2 B1 A1 A2 B1 A1
R
S
S
+
A2
+
10
11
R
B1 15 A1
A2
6 1 2
10
S1 S2
11
AC 50/60Hz UC AC/DC DC 10%
Y1 Y2
A2 B1 A1
R
A2 25
B1 15 A1
A2 25
Y2 17 A1
6 1 2
10 11
6 1 2
10 11
6 1 2
+
7 5
R
B1 15 A1
+
+
+
AC 230 V
UC110-240 V
UC110-240 V
UC110-240 V
AC110 -120 V
UC 24 - 60 V
UC 24 - 60 V
UC 24 - 60 V
UC 24 V
10 6 2
Ordering no. (P)
+
(P)
S1 S2
C52 / .... V
C53 / .... V
C55 / .... V
C56 / .... V
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
7 5 4 COM B1 Y1
A2 Y2 A1
10 6 2 +
Ordering example Timer C53 / UC110-240 V Socket C11A ✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
70
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
DISPLAY FUNCTION
TIME
t t
S INPUT R OUTPUT
t RESET t STOP
t t t1 t2 t1 t2 t A t P tV
RST STP
EWK ANM B F Q HGIP UV
Time Delay Relays
min Function Function switch
,
sec
Time setting Time inquiry Output ON/OFF
2
Option* Solid-state output for C53, C55 (instead of contact)
C53.3 C55.3
C53.4 C55.4
For AC or DC load 0,5A10-265VU
For DC load 2A 24VD
3
3
18
R
18
PNP
K
A2 17 A1
RL
10 1 2
+ UC110-240 V
R
K
A2
A1
10
2
RL
+ DC 24 V
UC 24 - 60 V C53.3 / ...V
C53.4 / ... V
C55.3 / ...V
C55.4 / ... V
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
71
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
72
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
Time Delay Relays
Plug-in Time Delay Relays
2
• RS Series • C Series • CX Series
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
73
KAT 2008
Plug-in Time Delay Relays
11
RS121
and otheres: www.comat.ch
RS 121
RS 121.P
RS 121.R
Time Delay Relays
Multifunctional Time Delay Relay
Multifunctional Time Delay Relay
Multifunctional Time delay Relay
Field proven since many years. The plug-in timer series from comat for highest quality requirements and unattained versatile operation.
• 5 functions • 2 change-over contacts • potential-free triggering or sensor PNP/NPN
• 5 functions • 2 change-over contacts • potential-free triggering or sensor PNP/NPN • with connection for remote potentiometer
• • • •
E
E
E
Triggering
E 3 4 1 A1
A2
Triggering
Function (page ✹)
S +
W
W
A K N
Time range
10ms -100h
10ms -100h
10ms -100h
Partial range
ms; s; min; h
ms; s; min; h
ms; s; min; h
5 A 250 V A
5 A 250 V A
5 A 250 V A
MAX
S NPN
Diagram
9 8 7 5
Connection with socket C11A
34 32 24 22
R
+ + 3 4 1 A1
A2
28 26 18
AC 50/60Hz UC AC / DC DC
25
15
A2 31
21
10 11
6
10%
1M 1
4
7
1
10
3
2 3
9 8 7 5
3 4
t 1
18
R
15
A1
A2 31
21
2
10 11
6
3 4
34 32 24 22 16
1
16
R
15
A1
A2 31
21
2
10 11
6
A1
1
+
2
+
AC 220-240 V
ATX
AC 220-240 V
ATX
AC 220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
UC 24-48 V
UFK
UC12 V
UCB
DC110-240 V
DNX
Ordering no.
6
18
+
+
5
STOP RST
34 32 24 22
PNP/ NPN
EXT POT
9 8 7 5
3 4 16
t - STOP t - RESET
A K N
EXT POT 1M
3 4 1 A1
W
A K N
PNP
A2
5 functions with t-stop and t-Reset function 1 change-over contact potential-free triggering or sensor PNP/NPN
RS 121/ ....
RS 121.P / ....
RS 121.R / ....
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
8 9
2
max. 50m 7 5/6 Z2 Z1 16
CS1/2
4
38x72cm
Built-in potentiometer SP-01/1M (page ✹)
(M4)
C-A2
Ordering example
FOR PLUG-IN MODULES
Timer RS 121/ATX Socket C11A
FS-23 4
20
92
9
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
74
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Repeat Cycle Timer
11
Time Delay Relays
RS122
and otheres: www.comat.ch
RS 122-M
RS 122-MH
RS 122-H
Cycle Timer
Universal Cycle Timer
Universal Cycle Timer
Universal Cycle Timer
Field proven since many years. The plug-in timer series from comat for highest quality requirements and unattained versatile operation.
• pulse or interval start • Time range 0,1s-30min • 2 change-over contacts
• pulse or interval start • Time range: pulse 0,1s-30min interval 0,1min-30h • 2 change-over contacts
• pulse or interval start • Time range 0,1min-30h • 2 change-over contacts
I
I
I
P
P
P
t I: 0,1s-30 min t P: 0,1s-30 min
t I: 0,1s-30 min t P: 0,1min-30h
t I: 0,1min-30 h t P: 0,1min-30 h
5 A 250 V A
5 A 250 V A
5 A 250 V A
Triggering
A2
E 3 1 A1 S +
Triggering
Function (page ✹)
Time range
MAX A2
2
3 1 A1 S +
Diagram
9 8 7 5
Connection with socket C11A
34 32 24 22 28 26 18
R
25
15
A2 31
21
10 11
6
9 8 7 5
3 4 16
28 26 18
R 1
25
15
A1
A2 31
21
2
10 11
6
UC AC / DC DC Ordering no.
10%
3 4
34 32 24 22 16
28 26 18
R 1
+
AC 50/60Hz
9 8 7 5
3 4
34 32 24 22
25
15
A1
A2 31
21
2
10 11
6
16
A1
1
+
2
+
AC 220-240 V
ATX
AC 220-240 V
ATX
AC 220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
UC 24-48 V
UFK
UC12 V
UCB
UC12 V
UCB
UC12 V
UCB
DC110-240 V
DNX
DC110-240 V
DNX
DC110-240 V
DNX
RS 122-M/ ....
RS 122-MH / ....
RS 122-H/ ....
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
38x72cm
16 4
(M4)
C-A2
Ordering example Timer RS 122-M/ATX Socket C11A
FOR PLUG-IN MODULES
FS-23 4
20
92
9
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
75
KAT 2008
RS 321, 521 RS 41
Plug-in Time Delay Relay
11
0.1-1.5 s
1-15 s
0.35 ... 5 Hz 0.1s -15 m
1-15 m 0.1-1.5 m 8
2
10 14 12
4
6
RS 41-M
and otheres: www.comat.ch
RS 321 Time Delay Relay 11-pole plug-in time relay for highest requirement in regard to quality and performance. Application-oriented, universal employment, operator friendly.
Triggering
Triggering
3 4 1 A1 S +
RS 41-M
Digital Multifunctional Time Delay Relay
Digital Multifunctional Time Delay Relay
Economy Multifunctional Time Delay Relay
• 5 functions • 2 change-over contacts • potential-free triggering
• • • •
• • • •
E
E
W
digital time elapse display time stop function 2 change-over contacts potential-free triggering
W
W B
A
K
A K N
Time range
0,01s-99,9 h
0,01s-99,9 h
0,1s -15min
Partial range
s; min; h
s; min; h
s; min
5 A 250 V A
5 A 250 V A
MAX
6 A 250 V A t-STOP
3 4 1 A1
S NPN
Diagram
9 8 7 5
Connection with socket C11A
34 32 24 22 28 26 18
R
+
3 4 1 A1
25
15
A2 31
21
10 11
6
16
28 26 18
R 1
25
15
A1
A2 31
21
2
10 11
6
AC 50/60Hz
+
UC AC / DC 5 3 4 A2 6 1 A1
DC
S +
10%
16
28 26
R 1
A2 31
21
2
10 11
6
A1
1
ATX
AC110-120 V
ANP
UC 24-48 V
UFK
UC12 V
UCB
DC110-240 V
DNX
AC110-240 V
ANX
UC 24-48 V
UFK
DC110-240 V
DNX
RS 321/ ....
2
+
RS 521/ ....
AC220-240 V
ATX
AC110-120 V
ANP
UC 24-48 V
UFK
RS 41-M / ....
S
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
+
3 4 5 A2 6 1 A1
25
A1
+
AC220-240 V
Ordering no.
3 4
34 32 24 22
+ NPN
9 8 7 5
3 4
34 32 24 22
S
5 3 4 A2 6 1 A1
9 8 7 5
3 4
FS-23
S
FS-40 16
+
4
(M4)
38x72cm
A2
E
A K N
PNP
A2
5 functions 1 change-over contact potential-free triggering with front cover
36x40cm
A2
E
Function (page ✹)
RS 521
C-A2
5
Ordering example
FOR PLUG-IN MODULES
Timer RS 321/ATX Socket C11A
4
20
92
9
85
9
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
76
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Plug-in Time Delay Relay
11
Time Delay Relays
CPX, CTI CEA
and otheres: www.comat.ch
CPX-519 Digital Multifunctional Time Delay Relay
Time Delay Relay Field proven since many years. The plug-in timer series from comat for highest quality requirements and unattained versatile operation.
Triggering
E
• • • •
S +
S +
Time Delay Relay
• • • •
• 2 change-over contacts • potential-free triggering
Rest interval can be set separatley digital time elapsed display 2 change-over contacts potential-free triggering
I
W
2
E A
Time range
0,01s -999 min
2x 0,01s -999 min
0,1s -990 s
Partial range
s; min
s; min
s
6 A 250 V A
6 A 250 V A
6 A 250 V A
Diagram
9 8 7 5 3 4
9 8 7 5 3 4
9 8 7 5 3 4
Connection with socket C11A
34 32 24 22 14 12
34 32 24 22 14 12
34 32 24 22 14 12
28 26
R PNP 6
7
6
UC AC / DC DC
PNP 7
6
16
28 26
R
15
18
25
10%
16
28 26
R
15
18
25
16
15
A2 31
21 11 A1
A2 31
21 11 A1
A2 31
21 11 A1
10 11
6 1 2
10 11
6 1 2
10 11
6 1 2
+
AC 50/60Hz
S
+
6
18
25
NAMUR
5 6 A1
7 A2
7 A2
Digital Cycle Timer
5 6 A1
7 A2
7
CEA - 226
A K N
MAX
7
with digital time elapsed display 5 functions 2 change-over contacts potential-free triggering
E
Triggering
Function (page ✹)
5 6 A1
7 A2
CTI-519
AC110-240 V
+ ANX
AC110-240 V
+ ANX
AC220-240 V
ATX
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
UC 24-48 V
UFK
UC12 V
UCB
UC12 V
UCB
UC12 V
UCB
DC110-240 V
DNX
DC110-240 V
DNX
DC110-240 V
DNX
NAMUR
5 6 A1 +
Ordering no.
CPX-519 / ....
CTI-519 / ....
CEA-226 / ....
S
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
38x72cm
16 4
(M4)
C-A2
Ordering example Timer CPX-519/ANX Socket C11A
FOR PLUG-IN MODULES
FS-23 4
20
78
9
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
77
KAT 2008
Plug-in Time Delay Relay
11
CPX, CFG CTI
and otheres: www.comat.ch
CPX-129
CFG-126
Time Delay Relay
Multifunctional Time Delay Relay
Field proven since many years. The plug-in timer series from comat for highest quality requirements and unattained versatile operation.
• 5 functions • 2 change-over contacts • potential-free triggering
Triggering
E
Function (page ✹)
5 6 A1
7 A2
E
Triggering
S +
• individual setting of t1/ t 2 • 2 change-over contacts • potential-free triggering
F
W
G
Multifunctional Cycle Timer • Reset interval can be set separate • 2 change-over contacts
I
H
Time range
0,1s -15 h
2x 0,01s -15min
2x 0,1s -15 h
Partial range
s; min; h
s; min
s; min; h
6 A 250 V A
6 A 250 V A
6 A 250 V A
5 6 A1
7 A2
S +
Diagram
9 8 7 5 3 4
9 8 7 5 3 4
9 8 7 5 3 4
Connection with socket C11A
34 32 24 22 14 12
34 32 24 22 14 12
34 32 24 22 14 12
28 26
R PNP 6
7
6
UC AC / DC DC
PNP
7 A2
7
6
16
28 26
R
15
18
25
10%
16
28 26
R
15
18
25
16
15
A2 31
21 11 A1
A2 31
21 11 A1
A2 31
21 11 A1
10 11
6 1 2
10 11
6 1 2
10 11
6 1 2
+
AC 50/60Hz
S
+
6
18
25
NAMUR
5 6 A1
7 A2
7
Multifunctional Time Delay Relay with 3 double functions
A K N
MAX
7
CTI-129
+
+
AC220-240 V
ATX
AC220-240 V
ATX
AC220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
UC 24-48 V
UFK
UC12 V
UCB
UC12 V
UCB
UC12 V
UCB
DC110-240 V
DNX
DC110-240 V
DNX
DC110-240 V
DNX
NAMUR
Ordering no.
5 6 A1
CPX-129 / ....
CFG-126 / ....
CTI-129 / ....
S
+
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
38x72cm
16 4
(M4)
C-A2
Ordering example
FOR PLUG-IN MODULES
Timer CPX-129/ATX Socket C11A
FS-23 4
20
78
9
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
78
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Plug-in Time Delay Relay
11
Time Delay Relays
CEA, CWR
and otheres: www.comat.ch
CEA-126
CWR-102
Time Delay Relays
Multifunctional Time Delay Relays
Single Shot Relay
Field proven since many years. The plug-in timer series from comat for highest quality requirements and unattained versatile operation.
• on delay or off delay • 2 change-over contacts • potential-free triggering
• • • •
E
W
A
Q
Time range
0,1s -15 min
0,1-1,5 s
Partial range
s; min
Triggering
E 5 6 A1
7 A2
Triggering
Function (page ✹)
S +
MAX
6 A 250 V A
S +
9 8 7 5 3 4
9 8 7 5 3 4
Connection with socket C11A
34 32 24 22 14 12
34 32 24 22 14 12
PNP 6
7
6
28 26
UC AC / DC DC
PNP 7
6
25
16
28 26
R
15
18
25
10%
16
15
A2 31
21 11 A1
A2 31
21 11 A1
10 11
6 1 2
10 11
6 1 2
+
AC 50/60Hz
S
+
6
18
NAMUR
5 6 A1
7 A2
7 A2
6 A 250 V A
Diagram
R
7
N
5 6 A1
7 A2
7
2
3 functions function t1 = t 2 2 change-over contacts potential-free triggering
+
AC220-240 V
ATX
AC220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
UC12 V
UCB
UC12 V
UCB
DC110-240 V
DNX
DC110-240 V
DNX
NAMUR
5 6 A1 +
Ordering no.
CEA -126 / ....
CWR-102 / ....
S
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
38x72cm
16 4
(M4)
C-A2
Ordering example Timer CEA-126/ATX Socket C11A
FOR PLUG-IN MODULES
FS-23 4
20
78
9
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
79
KAT 2008
Plug-in Time Delay Relay
11
CX
and otheres: www.comat.ch
CX 38
CX 39
Time Delay Relays
Multifunctional Time Delay Relays
Star-Delta Timer
Electronic Timer Relay with mains triggering and 2 change-over contacts. Digital timing generated with RC-Oscilator and frequency conductor with LED indication of relay function.
• 3 functions • delay time ranges can be set individual • 2 change-over contacts • mains triggering
• adjustable - change-over pause. • On delay with instantaneous contacts (R1 = immediately / R 2 = t ) • 2 change-over contacts
F
Y = S E = D
Triggering 7 A2
E
Triggering
Function (page ✹)
5 6 A1 S +
H
Time range
0,1s -15 h
Partial range
s; min, h
t t
6 A 250 V A
6 A 250 V A
MAX 7 A2
5 6 A1 S +
5 6 A1
9 8 7 5 3 4
9 8 7 5 3 4
34 32 24 22 14 12
34 32 24 22 14 12
28 26
18
25
16
28 26
R1
15
25
18
R2
AC 50/60Hz
S
DC
10%
16
R1 ( ) R2 ( )
15
A2 31
21 11 A1
A2 31
21 11 A1
10 11
6 1 2
10 11
6 1 2
+
UC AC / DC 5 6 A1
0,1s -15 h 1-100 ms
Connection with socket C11A
S
+
7 A2
-
Diagram
R 7 A2
G
+
AC220-240 V
ATX
AC220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
UC12 V
UCB
UC12 V
UCB
DC110-240 V
DNX
DC110-240 V
DNX
+
Ordering no. 7 A2
CX 38 / ....
CX 39 / ....
5 6 A1 S +
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
38x72cm
16 4
(M4)
C-A2
Ordering example
FOR PLUG-IN MODULES
Timer CX 38/ATX Socket C11A
FS-23 4
20
78
9
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
80
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
Time delay Relays
DIN Time Delay Relays
2
• Multifunction Time Delay Relays • Extra slime Time Delay Relays 13 mm • DIN-A (Installation, distribution panel) • DIN-C (Industry) • 22,5mm Seies
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
81
KAT 2008
DIN Time Delay Relays ( mono-function) CRE, CRA AE, AA, CY
DIN
and otheres: www.comat.ch
AE2 AE2M
CRA1
CRE1
AA2 AA2M
CY1
Economy time delay relay • on delay • voltage controlled • LED for R.
Economy time delay relay • off delay • votage controlled • LED for R
Economy time delay relay
Economy time delay relay
Star-delta time delay relay
• • • •
• • • •
• with adjustable interval • Safety locking of the ouput
E
A
E
A
Y
Time range
0,5 s- 30 min
0,3 s- 30 min.
★ TF60 setting (page ✹)
s, min
s, min ★
AE2 0,8 s -1,5 min AE2M 0,1-12 min
AA2 0,8 s -1,5 min AA2M 0,1-12 min
t t -
6 A 250 V A
6 A 250 V A
10A 250 V A
10A 250 V A
6 A 250 V A
17
15
Economy Time Delay Relays Only 13 or 17,5mm wide. Ideal for applications with a fixed function E, A or Y. For snap-on installation in accordance with DIN 43880.
E
Triggering
on delay voltage controlled 1changeover contact Output-LED
off delay voltage controlled 1changeover contact Output-LED
Function (page ✹)
MAX
Triggering
+ R
A2 A1 A2 B1 A1 S
18
+
A2
16 A2
A1
B1 A1
Ordering no.
+
+
A1 15 B1
R
+
AC 50/60 Hz UC AC/DC
+
A1 15
R
S
+
18
0,5 - 60 s 50 /100 ms
A1 17
R
16 18 A2
16 18 A2
18 28 A2
+
AC 230 V, AC115 V
AC 230 V
AC 220 -240 V
AC 220 -240 V
UC110-240 V
AC115 V
AC115 V
AC110 -127 V
AC110 -127 V
UC 24 - 60 V
UC 24 V
UC 24 V
UC 24 V
UC 24 V
CRE1 / .... V
AE2 / .... V AE2M / .... V
CRA1 / ....V
AA2 / .... V AA2M / .... V
CY1 / .... V
BS13-K BS13-G (incl.paper)
45
TS 35
75
45
TS35
90
CY1
Timer CRE1/AC230V
4,2
13
44
11
17,5
2,5
Ordering example 5
44
20
8
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
82
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Multifunctional Time Delay Relays CRV, CSV CRT
LIM 13mm S
DIN
BUT. . . . .
Function: F/Q
Function: I/P
Time Delay Relays
CRV3 CRT3
2
and otheres: www.comat.ch
CRV1
CRV2
CSV2
CRV3
CRT3
Extra slim 13 mm Time Delay Relay System
Economy Time Delay and Blinker Relay
Universal Multifunctional Time Delay Relay
Multifunctional Time Delay Relay
Double Time Delay Relay
Universal Repeat Cycle Timer
for all timing functions from 50ms up to 60 hours. With only 13mm fitting width especially suited for use in the industrial inter-face sector.
• 3 functions • voltage controlled • LED for R
• • • •
like CRV2, but with solidstate ouput and connection for remote potentiometer.
• F (E and A) or (W and N) • t1/t 2 separately settable • LED for B1and R • Function switch at the right side of the device
• Pulse or pause start • t1/t 2 separately settable • LED for A1and R • Function switch at the right side of the device
F O
I P
E
E W B
Triggering
Function (page ✹)
2 delay functions 2 shot timing modes pulse shaping K LED for B1and R
E W
E W B B2
A K N
E A K N
Time range
0,5 s- 30 min
0,05 s - 60 h
8 ms -10 h
★ TF60 setting (page ✹)
s, min
s, min, h ★
s, min, h ★
t1: 50 ms - 60 h t2: 50 ms - 60 h ★
t1: 50 ms - 60 h t2: 50 ms - 60 h ★
6 A 250 V A
6 A 250 V A
1,5 A 24 V D
6 A 250 V A
6 A 250 V A
15
15
MAX
EXT POT
Triggering 17
18
15
R
A2 A1 A2 B1 A1 A2 B1 A1
18
Z1
R
Z2 K
S
+
S
+
S
+
A2
16 A2
A1
+
AC 50/60 Hz UC AC/DC DC 10% Ordering no.
O A2
B1 A1
18
R
R
18
R
+ B1 A1
+
16 A2
B1 A1
+
16 A2
16 A1
+
AC 230 V
AC 230 V
AC 230 V
AC 230 V
AC115 V
AC115 V
AC115 V
AC115 V
UC 24 V
UC 24 V
UC 24 V
UC 24 V
CRV1 / .... V
DC 24 V
+
CRV2 / .... V
CSV2 / .... V
CRV3 / .... V
CRT3 / ....V
BS13-K BS13-G (incl.paper)
EXT POT 100k 1
max. 50m 45
TS35
90
3 2
Z1 Z2
CSV2
5
Ordering example
4
Timer CRV1/ AC230 V 44
11
7 8
2
9 1
13
6
3 10
Built-in potentiometer SP-01/100 k (page ✹)
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
83
KAT 2008
AM, CIM XXXX
DIN
Multifunctional Time Delay Relays Universal Function Relay
NEW
and otheres: www.comat.ch
AM1
AM2
17,5 mm time delay relay system
Economy Time Delay and Blinker Relay
in compact design. Suited for snap-on installation in accordance with DIN 43 880. CIM1 mit Treppenhausautomat und Schrittschalter.
• • • •
E
Universal Time Delay Relay • • • • • •
on delay one shot leading edge 2 blinker functions Output-LED
E W B B2
Triggering
Universal Time Delay Relay with instantaneous contact
on delay off delay one shot leading edge pulse shaping K voltage controlled Output-LED
or both contacts delayed (programmable). Functions like type AM2. Display of control input B1(S) in addition to the output-LED.
E
Function (page ✹)
CIM1
AM3
A K
W
• 9 functions • stepping switch (S) • staircase lighting timer (LS) • 1 change-over contact • hand function switch for maintenance functions (ON/OFF)
E
E
A K
Universal Function Relay
B W
A K N B1 S LS
W
Time range
0,5 s - 60 min
0,5 s - 60 min
0,5 s - 60 min
Partial ranges
0,5-6s...5-60min
0,5-6s...5-60min
0,5-6s...5-60min
0,6 s-60 h sec, min, h
10 A 250 V A
10 A 250 V A
10 A 250 V A
16 A 250 V A
MAX
R2= S
Triggering
+
+
A1 15 A2 A1 A2 B1 A1 A2 B1 A1
AC 50/60 Hz UC AC/DC
R
R
A1 B1 A2
R
R2 26
R
28
16 18 A2
16 18 A2
16 18 22 24 A2
15 16 18
UC110 - 240 V
AC 220 - 240 V
AC 220 - 240 V
UC 24-240 V
UC 24 - 60 V
AC110-127 V
UC110-127 V
UC 24 - 60 V
UC 24 - 60 V,
AM1 / .... V
CIM1/ .... V
AM3 / .... V
AM2 / .... V
75
Ordering no.
+
25
S
+
21 B1
45
+
+
+
A1 15
TS 35
S
+
A1 15 B1
75
S
+
R2= R (25-26-28)
4,2
17,5
4,2
35
2,5
Universal function relay CIM1/ UC24-240V
2,5
Ordering example 5
44
20
8
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
84
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Multifunctional Time Delay Relays XXXX CM
ST OUR BE HORSE
Time Delay Relays
DIN
and otheres: www.comat.ch
2 CM1 17,5 mm Time Delay Relay System in compact design. (For snap-on installation in accordance with DIN 43 880, see series DINA and C13.)
E
CM1L
CM3
Universal Time Delay Relay
Universal Time Delay Relay
Universal Time Delay Relay
Universal Time Delay Relay
• • • • • •
like type CM1, but with extended time range.
like type CM1, but with time stop and reset input as well as connection for remote potentiometer 100k. 2 heavy current contacts.
• 7 functions • Mainenance switch ON/OFF • 2 seperate change-over contacts • supply voltages: DC12-24V or DC24-48/AC24-240V
on delay off delay one shot leading edge pulse shaping K voltage controlled LED for B1 and R
E
Triggering
CM2
E
E
E
Function (page ✹)
A K
Time range
50 ms-100 min
0,3 s -12 h
0,3 s -12 h
50 ms -60 h
Partial ranges
ms, s, min
s, min, h
0,3-3s...1,2-12h
ms, s, min, h
6 A 250 V A
6 A 250 V A
6 A 250 V A
5 A 250 V A
+
+
+
A1 15 B1 A2 A1 A2 B1 A1 A2 B1 A1 S
+
S
+
+
+
+
A1 15 27 B1 S
A1 15 B1
R
R
+
Ordering no.
B W
15 16 18 R
R
25 26 28
R
R
S
16 18 A2
16 18 A2
16 18 28 Z1 Z2 A2
A1 B1 A2
+
EXT POT
UC AC/DC DC 10%
A K N B1
W
RESET
Triggering
A K
W
STOP
MAX
A K
W
UC110-240 V 16 / ...60 Hz
UC110-240 V 16 / ...60Hz
UC110-240 V
DC 24-48 V /AC 24-240 V
UC 24 - 60 V
UC 24 - 60 V
UC 24 - 60 V
DC12-24 V
23
23
CM1/.... V
CM1L /.... V
CM 2 /.... V
CM 3 / .... V
CM2
CM3 LABEL
Z1 Z2
LABEL
TS 35
75
75
max. 50m 3 2
1
100k EXT POT 5
Ordering example
4
6 7
4,2
17,5
4,2
35
2,5
Timer CM1/UC110-240V
2,5
3
8
8 9
2 1
5
64
10
10
Built-in potentiometer SP-01/100k (page ✹)
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
85
KAT 2008
Multifunctional Time Delay Relays CNR, CT
DIN
and otheres: www.comat.ch
CT1
CNR1
CT1L
17,5 mm Time Delay Relay System
Time Delay Relay, no auxiliary voltage
Universal Repeat Cycle Timer
Universal Repeat Cycle Timer
in compact design. (For snap-on installation in accordance with DIN 43 880.
• Function runs after cut off power supply • Minimum triggering time 150ms only
• pulse or pause start • t1/ t 2 separately settable • LED for A1 and R
Like CT1 buth with extended time range.
A N
I P
I P
0,1s-12 min sec, min
t1: 0,1s-12 min t2: 0,5 s-60 min
t1: 0,5 s-60 min t2: 0,3 min-30 h
5 A 250 V A
6 A 250 V A
6 A 250 V A
E
Triggering
Function (page ✹)
no auxiliary voltage
Time range Partial ranges MAX
Triggering
+
+
A1 15 A2 A1 A2 B1 A1 A2 B1 A1 S
S
+
+
UC AC/DC
Ordering no.
+
A1 15
R
A1 15
R
R
S
+
16 18 A2
16 18 A2
16 18 A2
UC110-240 V
UC110-240 V
UC110-240 V
UC 24 - 60 V
UC 24 - 60 V
UC 24 - 60 V
CT1 / .... V
CNR1 / .... V
CT1L /.... V
TS 35
75
LABEL
Timer CIM1/ UC24-240V
4,2
17,5
2,5
Ordering example 8 5
64
10
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
86
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Multifunctional Time Delay Relays XXXX ECO
Time Delay Relays
DIN
and otheres: www.comat.ch
2 ECO 31 Multifunctional Time Delay Relays 22,5 mm
Economy Time Delay and Blinker Relay
Multifunctional Time Delay Relay
for timing functions from 0,1s up to 12 hours.
• 3 functions • voltage controlled • LED for R
• • • •
E
E W B
Triggering
2 delay functions 2 shot timing modes blinker pulse shaping K LED for R
E W B
Function (page ✹)
A K N
Time range
0,5 s - 20 min
★ TF60 setting (page ✹)
0,1 s -12 h ★
sec, min
sec, h
6 A 250 V A
6 A 250 V A
16 15 18
16 15 18
MAX
Triggering
R
A2 A1 A2 B1 A1
UC AC/DC
+
AC 230 V
AC 230 V
AC115 V
AC115 V
UC 24 V
UC 24 V ECO32 / .... V
ECO31 / .... V
65
4
32
987
Ordering no.
A2 B1 A1
+
TS35
AC 50/60 Hz
A2 A2 A1
90
+
1
S
+
R
S
10
2
Ordering example Timer ECO31/AC230V 22,5
70
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
87
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
88
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
Time Delay Relays
Specially Time Delay Relays
2
• CN Series Specially Time Delay Relays • SFR Serie Amplifier Relays, Switching Amplifier • SBV Amplifier Blinker • CPF Pulse Shaper • CCX Preset Counters
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
89
KAT 2008
Industrial Time Delay Relays CNS, CN
DIN
and otheres: www.comat.ch
CNS-4
CN 135
Industrial Time Delay Relays
Cascade Relay
Specially Time Delay Relays
CN135 with 2 change-over contacts. CNS-4 with 4 independent outputs.
• • • •
• 2 functions • connections for external potentiometer 1M • 4 outputs • detachable terminals • seismic approved according IEE 323 and IEE 344
E
ON cascades ON /OFF cascades 4 outputs detachable terminals
E4
Triggering
Function (page ✹)
E4
Time range
0.1s-30 min
Partial range
s, min MAX
Triggering
Y1 Y2
S
+
+
AC 50/60Hz UC AC/DC Ordering no.
S
+
A
R1 R2 R3 R4
0.1s-30 min
6 A 250 V A
s, min
8 A 250 V A
Y1 Y2
A2 B1 A1 A2 B1 A1 A2 B1 A1
S
S t t t t
EA 4
A1 A2 B1 A2 B1 A1
E
On delay
EA 4
R1
R2
R3
On delay Off delay
R4
t t t t 15 18 25 28 35 38 45 48
R
Y1 Y2 B1
R
S
S
+
A1 15 25
t t t t R1 R2 R3 R4
16 18 26 28
Z1 Z2 A2
EXT POT
AC 220-240 V
ATX
AC 220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
CNS-4 / .... V
CN 135 / .... V
EXT POT 1M 3 2
1
max. 50m Z1 Z2
CN135 5
6
4
7
1
10
3
8 9
2
Ordering example Cascade Relay CNS-4/ ATX
Built-in potentiometer SP-01/1M (page ✹)
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
90
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Universal Timer Module
Time Delay Relays
CU
and otheres: www.comat.ch
2 CU23
E
Example for external wiring
Universal Timer Module for Print Mounting • the time module for industrial application • 5 functions • t -stop • PNP/NPN output
sec 18
Time range Partial range
x1 1 x6 1 x30 1
2 3 4
E
Triggering
Function (page ✹)
A K N
Series resistor Rv
W
0.01s-300 min
Partial range
s, min
10 11 5
E
6 7 8 9 10
10-28 V
A
+ PNP
CU23
+ 6 7 8 9 10
K
1- 300 min
0,05-1min 0,3 - 6min 1,5-30min
1- 10min 6-60min 30-300min
15
14
14
15
1M
1M
6 7 8 9 10
N A 8 E 9 K 10 1
N
W
10%
DC12-24 V
Ordering no.
CU23 / .... V
– NPN
R
11 12 -
100K 560 nF 1M
Built-in potentiometer (page ✹) SP-01/100k SP-01/1M 6
4
7
1
10
3
R
13
8 9
2
14 Rt 2
3
4 15
t x1 x6 x30
–
S
5
+
6 7
6 7 8 9 10
DC
min s
5 17 18 19 20
S
+
0,05- 30 m
0,05-1s 0,3 - 6s 1,5-30s
Wiring (view from the back)
t
6 7 8 9 10 S
0,05- 30 s
0,01-0,1s 0,06-0,6s 0,3-3s
100K
+ 10 11 5
0,01- 3 s
120 mA 24 VD Programming
Triggering
19
Adjustable resistor Rt
STOP
MAX
17
6K8
Extender capacitor Ct
Time range
min 19
150 mA
with soldering pins for printed circuit mounting.
Ct
120 mA
Universal Timer Module
Time stop ( t - STOP) = the elapsing time is interrupted
Ordering example Timer module CU23/DC12-24V ✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
91
KAT 2008
Amplifier Relays
11
SFR
and otheres: www.comat.ch
SFR1
SFR2
Amplifier Relay
Amplifier Relay
Amplifier Relay
Supply unit with integrated switching amplifier for 3-wire PNP sensors, NAMUR as per DIN 19234 as well as for contact triggering also with external power supply. The input wiring is specifically suitable for long feed wires.
• switching amplifier for: - PNP 3 wire sensors - NAMUR sensors • potential-free contact • integrated sensor supply voltage 24V • The input wiring is specifically suitable for long connection lines
• switching amplifier for: - PNP 3 wire sensors - NAMUR sensors • potential-free contact • integrated sensor supply voltage 14V • The input wiring is specifically suitable for long connection lines
5 A 250 V A
6 A 24 V U
MAX
Diagram
9 8 7 5 3 4
9 8 7 5 3 4
Connection with socket C11A
34 32 24 22 14 12
34 32 24 22 14 12
R
R
A2 31
21 11 A1
A2 31
21 11 A1
10 11
6 1 2
10 11
6 1 2
+ Output supply
DC output supply Output voltage Output current max.
Triggering
+ +
+
DC 22...25V 100mA
5 6 7
output active output inactive output inactive
5 6 7
DC 14V 4mA
5 6 7
output active output inactive output inactive
5 6 7
NAMUR sensor Not damped Damped Wire break
+
+
PNP three-wire sensor
10-30VD
+ O 5 6 7 External power supply / contact On-signal Off-signal triggering current Parallel load energy
Galvanic isolation
DC +18...+30V DC –30...+7,5V 7mA bei DC24V 100V 10ms/1Hz
5 6 7
+
18-30VD
S
S 5 6 7
5 6 7
>2kV (triggering to supply and output) >2kV (triggering to supply and output)
UC AC / DC
Ordering no.
AC 220-240 V
DC +10...+30V DC –10...+5V 7mA bei DC24V 100V 10ms/1Hz
+
10-30VD
S
5 6 7
S 5 6 7
>2kV (triggering to supply and output)
AC110-120 V
UC 24V
SFR1/ ....
SFR2 / ....
System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery).
16 4
38x72cm
AC 50/60 Hz
+
(M4)
C-A2
Ordering example
FOR PLUG-IN MODULES
Amplifier relay SFR1/AC220-240V Socket C11A
FS-23 4
20
92
9
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
92
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Amplifier Relays
SBV
K
K
70
80
60
90
Time Delay Relays
11
UB 10...45V IS 5...15 mA I RL max. 10 A
and otheres: www.comat.ch
SSV11
SBV11 Blinker and Aplifier
Amplifier-Blinker
Switching Amplifier
Relay with solid state output specially suitable for frequent switching cycles.
With solid state output. Adjustable electronic flasher for 60-90 pulses/min. Switching voltage 10-45V DC and switching loads up to 10A. The short circuit limiter and the overload proof design alows wear free switching of filament lamps in general but as well as all ohmic, inductive and capacitive loads. Triggering supply is indicated by LED.
With solid state output. For applications in automation where high switching cycles and loads up to 10A at 10-45V DC are required. For example for solenoids, magnetic clutches and other ohmic inductive or capacitive loads. With built-in short circuit limiter and over-load protection circuit, this amplifier switches wear free and guarantees high service life. LED display for trigger signal.
Function (page ✹)
B
Time range
60-90 I/min MAX
10 A 10 - 45 VD
10 A 10 - 45 VD
Diagram
Amplifier
S
Connection with socket CS11
8
S
Blinker
7 6 5 4
32 24 21 22 12
8
7 6 5 4
32 24 21 22 12
S K
K
34 A2 31 11 A1 14
34 A2 31 11 A1 14
9 10 11 1 2 3
9 10 11 1 2 3
+
+
DC
10%
SBV11/ ....
DC12-36 V
DC12-36 V SSV11/ ....
38x72cm
Ordering no.
DC 24-48 V
+
Ordering example Amplifier relay SBV11/DC12-36V Socket CS11 ✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
93
KAT 2008
2
Pulse Shapers CPF
DIN
and otheres: www.comat.ch
CPF11
CPF22
CPF Pulse Shapers
Single Channel Pulse Shaper
Double Channel Pulse Shaper
with the timing functions K, L and A are specialist devices for the lengthening or the limitation of control pulses. In this fully electronic design with the facility for also con-necting NAMUR sensors they are the ideal interface modules in modern control systems. Always there where fast processes, high rotations, i.e. the briefest pulses, are to be evaluated, the costeffective solution is: CPF Pulse shapers.
• Input reversible (E-E) • Input and output times separately settable • 3(6) functions to choose • Additional free wheel diode 1A • LED display for E and Q
• Input/output galvanically isolated 4kV • Input and output times separately settable • 2 functions to choose • LED output display for each channel
K L A
K A
Function (page ✹) Time range
input pulse
output pulse
input pulse
output pulse
≥1/ 5 ms
5 ÷600 ms
≥ 0,5 / 2,5 ms
50 / 200 ms
+
15÷32VD
NAMUR sensor
Three-wire sensor
+
E2
S PNP
4kV
E1
E1
K
150mA
CPF
CPF
O
+
FD
10÷45VD
RL 10%
Ordering no.
DC 24 V
PNP
1O
+
0,8A
DC
2S
1E1 1E2 2E1 2E2
11K 5K6
4K7
3K3
+
1S
+
E1 E2
PNP
S NAMUR
+
15÷32VD
S
15…32V
19…28V
+
+ +
2O
1RL
2RL
DC 24 V
CPF11 / .... V
CPF22 / .... V
CPF11
TS 35
75
CPF22
Pulse shaper CPF11/DC24V
4,2
2,5
Ordering example 17,5
8 5
64
10
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
94
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
11
Time Delay Relays
CCX
Preset Counters
and otheres: www.comat.ch
CCX-350
CCX-550
Functions
Preset Counters
Preset Counters
Preset Counters with display
Electronic pre-select counter with 2 change-over contacts. Digital value display with LED function indication. Suitable for front panel mounting.
Switching after the preset number of pulses are reached.
Switching after the preset number of pulses are reached. • 7 digit LED display
Triggering: • potential-free contact • NAMUR sensor • PNP
n
Preselection
0 - 999
0 - 999
Count frequency
200Hz
200Hz
6 A 250 V A
6 A 250 V A
MAX
CI
CE CK
CE
Q
U n
Diagram
R Q
U
t
7
6
7
6
7
6
NAMUR
COUNT
C
R RESET
UC AC/DC
7 6 5 4
8
7 6 5 4
32
24 21 22 12
32
24 21 22 12
ON OFF
OUTPUT
Q
Q
34 A2 31 11 A1 14
34 A2 31 11 A1 14
9 10 11 1 2 3
9 10 11 1 2 3
AC220-240 V
ATX
AC220-240 V
ATX
AC110-120 V
ANP
AC110-120 V
ANP
UC 24-48 V
UFK
UC 24-48 V
UFK
CCX-350 / ....
Q
U = Voltage C = Count R = Reset Q = Output relays
CCX-550 / ....
38x72cm
Ordering no.
C
R RESET
8
OUTPUT
AC 50/60 Hz
C
n
Q is active for t 75...125ms on the preselected pulse. The cycle starts again at the beginning. Q and C can be reset with the reset button.
NAMUR
COUNT
1
R
CI
Connection with socket CS11 6
C
Q is active during the preselected number of pulses and can only be reactivated after a reset. Q and C can be reset with the reset button.
PNP
7
1
CK
CI
1 n 1
PNP
C R
1
CE CK
1
Q is active after reaching the preselected number of pulses. Q and C can be reset with the reset button.
Triggering: • potential-free contact • NAMUR sensor • PNP
Function
2
U 1
Ordering example Counters CCX-350 Socket CS11 ✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
95
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
96
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Time Delay Relays
Time Delay Relays
Sockets and Accessories for Time Delay Relays
2
Sockets for Time Delay Relays • Economy Sockets • System Sockets • Chassis Sockets • Accessories pour Sockets Accessories for Time Delay Relays • External Potentiometer • Surface Mounting Case • Divers
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
97
KAT 2008
8
Socket
11
Socket for Time Delay Relays
C11A
EC11
CS11
EC 8
CS 8
System socket 11-pole,
Economy socket
Socket 11-pole
Economy socket
Socket
with white cover and plug-in connector C-A2. (standard delivery)
11-pole
Snaped cover sheet with wiring diagram. (backside neutral white)
8-pole
8-pole
C12B
C12B1
C12B0
CS18
11 PGL
System Socket 11-pole, 12 terminals (+B1). SC-3 inserted for B1-2-A1. Cover transparent.
System Socket 11-pole, like C12B, but with imprinted contact diagram for 3 pole industrial relays.
System Socket 11-pole, similar to C12B. Prepared for CT system (without SC-3, SD-1).
Socket 8-pole for time delay relays C81...C85 series.
Socket 11-pole for chassis mounting with soldering pins.
C81...C85
CT2
CT3... CS... C50... C60... RS... C... CX... SSR... CCX...
CT30...CT36
Suitable for product families
Socket types
Connection layout (from left to the right)
C11A
System-Sockel
●
A
EC -11
Economy-Socket
●
A
CS -11
Socket
●
B
●
C12 B
System Socket
●
A
C12 B0
System Socket
●
A
C12 B1
System Socket
●
CS-18
Socket
CS -8
Socket
EC -8
Economy Socket
11 PGL
Chassis Socket
A ●
●
–
●
–
●
– –
A 9 8
11
7 5
6
4
3
1
B 8 76 5 4
9 11
13
● recommended ● applicable
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
98
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Socket accessories and dimensions Sockets
Socket accessories
Socket types
Description
C11A
CA-11
Coding ring (VE 5 pieces)
EC-11
CS-11
C12B
C12B0
C12B1
●
●
●
EC-8
CS-8
CS-18
● ●
CA-8
Coding ring (VE 5 pieces)
C-A2
Neutral connector bridge (VE 5 or 50 pieces)
●
●
●
●
●
●
●
Time Delay Relays
Type
SC-3
A1-Connector (VE 10 pieces)
LH-1
Marking lable holder (VE 5 pieces)
SL-36
Marking lable holder (VE 5 pieces)
●
●
SP-36
Marking lable strips (VE 5 pieces)
●
●
PS-W
Marking lable strips (VE 5 pieces)
L-16
Marking lable strips (VE 5 pieces)
●
●
●
●
SD-1
Cover lid transparent (VE 5 pieces)
●
●
●
●
SD-1W
Cover lid white
●
●
●
●
SS-T
Cover transparent
●
SS-W
Cover white
●
SA-0
Wall braket
●
LABELS
8
7 6 5
4
●
●
TEST
SP-36
32 24 21 22 12
15
SL-36 3,2
5
ø 5,3
68
8
7
29,5
TS 35
3
34 A2 31 11 A1 14
9 10 11 1
4
20
CA-8 CA-11
2 3
CS-8 CS-11
38
9
7
8
5
3
4
4
2
3
1
PS-W L-16
24 22 14 12
12345 LH-1
S+S, wieland
SS-T
16 30
max 40
75
75
4
M3 FOR M4
10
10
11
CONNECTOR
1
B1
A1
12
2
C11.. C12..
22,5
6
5
4
3
9
8
7
5
3
4
22
12
14
34
32
24
22
14
12
7
11
3,5
CS-18
for M3 14
22,5
EC- 11
62
for M4
8
M4 M3 28
23
CS-18
8A2 6B1 5 7A1
A2
21
11
A1
7
8
1
2
38
24.2
8
62
SS-W
SA-0
24
18
EC 8
5
21
SD-1 SD-1W
EC- 8
4
3
6
for modules
6
22
C-A2
SC-3
38
4
20
6
4
8
C-A2
FOR PLUG-IN MODULES A2
1
SWISS
A2-CONNECTOR
TS 35
C-A2
2
28 for M3
A2
31
21
11
A1
10
11
6
1
2
EC11
38
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
99
KAT 2008
2
Accessories pour Time Delay Relays Accessories External potentiometer
Front panel mounting FZ-50L Consisting of front frame with cover, retaining clips and socket (11 PGL).
SP-01/1M
SP-01/100K 1...6
FERNPOTENTIOMETER REMOTE POTENTIOMETER
SET No. SOCKEL
IP 65
8
2
9
33 + 00,6
1M 100K 1 2
KLEMMFEDER RETAINING CLIP
FRONT
10
1
FRONT FRAME
48
7
45 + 00,6
42,6
1 2 3
6
5 4 3
FRONTRAHMEN
FZ-50L
SOCKET
22…23
3
1,5 .. 5
36
56
30
36
22
Front panel mounting FZ-23
Front panel mounting FZ-40
Consisting of front frame with cover, retaining clips.
Consisting of front frame with cover, retaining clips.
KLEMMFEDER RETAINING CLIP
SET No.
FZ-23
FRONTRAHMEN FRONT FRAME
18
68
1.. 3 15,5 9
KLEMMFEDER RETAINING CLIP
SET No.
FZ- 40
FRONTRAHMEN FRONT FRAME
1.. 4
70 + 00,6
FRONT
38 + 00,6
50
72
40,5 + 00,6
FRONT
36,5 + 00,6
8 42
Marking labels
82
49
15,5
75 / 89
Transparent covers
12
Retaining clips
Large and small for relay system C13.
Matching diverse cases and sockets.
BS13-K BS13-G
HF-24 GC-T GC-W
FA-50 FS-23 FS-40
PLUG-IN MODULE
FS-C FS-R FS-xx
Retaining clips Matching diverse cases and sockets.
HF-32 S3-C
SWISS
HF-50
INDUSTRIAL RELAY
C-A2
PLUG-IN MODULE
HF-33 S3-CT TIME CUBE
INDUSTRIAL RELAY
FS-C FS-R FS-C5
✹ Function Page: 52; ★TF- 60 setting: Page 53; Socket and Accessories: Page 97
100
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Accessories pour Time Delay Relays Accessories
External potentiometer Time delay relays CN 135
Product families
Descriptions
BS13-G
Marking label strip large
BS13-K
Marking label strip small
FA-50
Front cover
CT30...
Type
CS... C50... C60...
RS... C... CX CCx SSR
Accessories for time delay relays and AP-surface mounting case
● ● ● ●
FS-23
Front cover
FS-40
Front cover
FS-C5
Cover for relay C30
●
FS-R
Cover for relay C3-..
●
FS-..
Cover for relay C5-..
FZ-23
Front mounting set
FZ-40
Front mounting set
FZ-50L
Front mounting set (incl. Socket 11PGL)
2
●
● ● ● ●
GC-T
Relay retaining clip transparent
●
GC-W
Relay retaining clip white
● ●
HF-24
Retaining clip
HF-32
Retaining clip for relay C30
HF-33
Retaining clip for relay C20/C30
HF-50
Retaining clip
S3-C
Retaining clip for relay C3
S3-CT
Retaining clip for relay C2/C3
RG
Surface mounting case DIN rail
RG-D2
Surface mounting case DIN rail
RG-C2
Surface mounting incl. Socket CS-8
● ● ●
●
●
●
● ● ●
●
●
●
●
RG-C3
Surface mounting incl. Socket CS-11
RG-50
Surface mounting incl. Socket CS-11
RG-23
Surface mounting incl. Socket CS-11
RG-40
Surface mounting incl. Socket CS-11
● ● ● ● ●
●
Surface Mounting Case with built-in DIN rail or with socket (Screws touch safe) Gray polymer with or without window..
RG - ...
RG
RG - ...
3
50
96
96
TS 35 7,5
94
125
Socket
4,5
Time Delay Relays
RS 121.P
DIN B /C
CS2
DIN A
CS1
C13...
SP-01/1M 액
C80...
CM2
CT3...
CSV2
CT2...
SP-01/100 k 액
RS 40
Type
. . . mm
83,5
97
3
3 24
67
Type RG RG-D2 RG-C2 RG-C3 RG-50 RG-23 RG-40
Socket DIN DIN CS - 8 CS -11 CS -11 CS -11 CS -11
WxH --21 x 46 mm 36 x 36 mm 36 x 36 mm 36 x 50 mm 39 x 73 mm 37 x 40 mm
3
97
✹ Function Page: 52; ★ TF- 60 setting: Page 53; Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
101
KAT 2008
Notes
102
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Installation Relays
Installation Relays
3
• Power Relays • Step-on Step-off Relays • Staircase Lighting Timers • Power Step-on Step-off Relays • Installation Contactors
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
103
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
Lloyd’s; IEC 61810; EN 60974
104
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Step-on Step-off Relays Staircase Lighting Timer
CIM1
Step-on Step-off Relay
Power Relays
Staircase Lighting Timers
Staircase Lighting Timer for central control
Installation Contactors
Pa ge
t
ty p e
Co nta c
et So ck
an ge 0,6 s-60 min
DIN 35
16 A 106
CRS1C
DIN 35
6 A 106
Power Relay
B103
DIN 35
10 A 107
Power Relay
A 333
DIN 35
10 A 107
Staircase Lighting Timer
AL1
30 s -10 min
DIN 35
10 A 108
Staircase Lighting Timer
AL 2
30 s -10 min
DIN 35
10 A 108
Staircase Lighting Timer
AL 3
30 s - 60 min
DIN 35
10 A 108
Staircase Lighting Timer for central control
AL 4
30 s -60 min
DIN 35
10 A 109
Staircase Lighting Timer for central control
AL 5
DIN 35
10 A 109
Installation Contactor
RIC 20
DIN 35
20 A 110
Installation Contactor
RIC 25
DIN 35
25 A 110
Installation Contactor
RIC 40
DIN 35
40 A 110
Installation Contactor
RIC 63
DIN 35
63 A 110
AUX Block
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
RIC-AUX
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
6 A 110
105
KAT 2008
Installation Relays
Step-on Step-off Relays
Tim er
Se rie s
Installation Relays
3
CIM, CRS
Step-On Step-Off Relays
DIN
Step-On Step-Off Relays
Type: AS1 No longer available substituted by CIM1
17,5mm
13 mm CRS1C
CIM1 Step-On Step-off Relay
Step-On Step-Off Relay/ Staircase Lighting Timer
• with integrated LED display • no external wiring required • Mounting on DIN rail TS35
and 7 additional time functions including ON/OFF manual switch for maintenance purpose. LED status display and integrated test switch.
2000V
Test voltage:
Tamb. operation/storage: -20..+60/- 40..+85°C Railway version up to -46°
0,6 s - 60 h 16 A 250 V A
Time Range MAX MIN
and otheres:
www.comat.ch
E
Step-On Step-Off Relay
E
Triggering
Function (page ✹)
Test voltage:
• • • •
2000V
and otheres:
6 A 250 V A
MAX MIN
10mA 12V
B W 14 12
A K N B1 S LS
11 12
+
Triggering
(DC-version)
A1 B1 A2 A2 A1 A2 B1 A1 A2 B1 A1 S
13mm series 1 x CO for permanente drive supply failure protected Integrated LED and coil wiring
Tamb. operation/storage: -20..+60/- 40..+85°C
www.comat.ch
10mA 12V
Step-On Step-Off Relay
• with integrated LED display • no external wiring required • Mounting on DIN rail TS35
S
S
+
+
R
+
+ A2
15 16 18
A1
+
Data at Tamb =20°C
Data at Tamb =20°C
Contact material Switching current /voltage Switching power AC1 // DC1 Switching cycles mech.
AgNi 16A 250V 4000VA // 384W 30 x 10 6
Contact material Switching current /voltage Switching power AC1 // DC1 Switching cycles mech.
AgNi 15A/20ms 1500VA // ...180W DC: 10 x10 6; DC ≥15%
Operating voltage Power consumption AC /DC Triggering delay / release time Glow lamp load
AC ±20% / DC ±20% 1,2VA, 430mW 10ms / 10ms ≤ 10mA
Operating voltage Power consumption Triggering delay / release time
AC ±15% / DC ±15% 2VA 1,5W Recommended triggering time ≥ 50ms
AC CRS1C / AC 230 V
50/60Hz
DC
UC CIM1/ UC 24 -240 V
/
CRS1C / DC 24 V
≤ 10%
BS13-K BS13-G
Ordering example
45
TS35
90
45
TS 35
75
(incl.paper)
4,2
17,5
2,5
Ordering example
Step-on step-off relay CIM1/ UC 24-240 V
5
44
20
Step-on step-off relay CRS1C /AC 230 V
13
44
11
✹ Function Page: 52
106
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
B103
A 333
DIN
Power Relays • with mechanical output status • A333 with DIN 45mm cap dimension Test voltage:
Power Relays
2000V 2000V
Power Relay
Power Relay
• 1 pole power relay with free-wheeling diode and reverse polarity protection • Integrated LED position indicator
• 1 pole power relay with free-wheeling diode and reverse polarity protection • Integrated LED position indicator
Installation Relays
B103, A333
Power Relays
Tamb. operation/storage: -20..+60/- 40..+85°C
3 MAX MIN
and otheres:
www.comat.ch
10 A 250 V A
10 A 250 V A
10 mA 12 V
10 mA 10 V
+
+
A1 11
Connection lay out (top/bottom)
R 12 14 A2
A1 11 21 31 32 R
R
R
12 14 22 24 34 A2
Data at Tamb = 20°C
Contact material Switching power AC1 // DC1 Peak inrush current Switching cycles mech./elec. (AC1)
AgCdo 2200VA // ≤150W (DC) 16A 2x 10 7
AgCdo 1500VA // ≤ 300W (DC) 30A 2x 10 7
Operating voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
AC ±15% / DC ±15% 2VA, 1,5W 20ms / 12ms
0,8...1,1UN 2,2VA, 1,2W 18ms / 10ms
AC 50/60Hz
220-240, 110-127 B103 /AC .... V
48, 24, 12 A333/ DC .... V
DC ≤ 10%
UC 50/60 Hz /
230, 110, 48, 24 A333/AC .... V
48, 24, 8-12 B103 / UC .... V
A 333
Ordering example Power Relay B103/AC220-240V ✹ Function Page: 52
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
107
KAT 2008
Staircase Lighting Timers Staircase Lighting Timers Staircase Lighting Timers AL1... AL3
DIN
AK
E 120 A P
AL1 Staircase Lighting Timers • Trigger status indication • Manual-Auto switch Test voltage:
2500V
Tamb. operation/storage: -45..+60 / - 45..+85°C
Time Range and otheres:
www.comat.ch
MAX MIN
B1
L
Staircase Lighting Timers
Staircase Lighting Timers
• For small to medium-sized installations • Single contact 10A, 250Va • 30s-10min running time, infinitely adjustable • subsequent time operation from zero • Manual ON
• With special contact for high lamp loads • 120A special early make contact • Glow lamp load with AC • 30s-10min running time, infinitely adjustable • subsequent time operation from zero • Manual ON
• With stepping switch functions LS and S • 120A special early make contact • Glow lamp load with AC • 30s-1h running time, infinitely adjustable • subsequent time operation from zero • Manual ON
30 s-10 min 10 A 250 V A
30 s-10 min 10 A 250 V A
30 s-60min 10 A 250 V A (120A peak)
10 mA 12 V
10 mA 12 V
(120A peak)
10 mA 12 V
L
L
L LS S L
L 10 A
t
Y1 Y2
AL3
Staircase Lighting Timers
L
Function/Triggering
LS
AL2
10 A
10 A
10mA
40mA
40mA
t
Y2 Y3
A1 17 B1
S
A1 17
R
Function Triggering (Page ✹)
18 18 A2 1200W N
B1 B1
A1 17 B1 Y1 Y2 Y3 R
R 18 18 N
A2 A2
1200W
Y4 Y5 A2
18 18 N
2000W
N
Data at Tamb =20°C
Contact material Switching power AC1 // DC1 Peak inrush current Switching cycles mech./elec. (AC1)
W+AgSnO2 2200VA // ≤ 440W (DC) 120A /20ms 3x 10 7
W+AgSnO2 2200VA // ≤ 440W (DC) 120A /20ms 3x 10 7
W+AgSnO2 2200VA // ≤ 440W (DC) 120A /20ms 3x 10 7
Operating voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time Glow lamp load
0,85...1,1UN 2,5VA 50ms /≤ 300ms ≤ 10mA
0,85...1,1UN 2,5VA 50ms/≤ 300ms ≤ 40mA
0,85...1,1UN 2,5VA, 1,5W 60ms/≤ 300ms ≤ 40mA
AC 50/60Hz
220-240, 110-127 AL1/AC .... V
UC 50/60 Hz /
220-240, 110-127 AL2/AC .... V
220-240, 110-127, 48-60 AL3/AC .... V 24 AL3/ UC .... V
Ordering example Staircase Lighting Timer AL1/AC220-240V ✹ Function Page: 52
108
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
AL4 ... AL5
DIN
Staircase Lighting Timers Staircase Lighting Timers Power Step-on Step-off for central control for central control Relay for central control AK
10 A 250 V A
10 mA 12 V
10 mA 12 V
10 mA 12 V
S CENTRAL
+
CENTRAL
A1 17 B1
C1 C2
A1 17 B1 C C1 C2
R B1 C1 C2
AL5
R
18 18 Y1 Y2 Y3 A2
A1 11 B1
R
C1 C2
C1 C2
A3 A2 A2
A3 A2 A2
R
18 18 Y1 Y2 Y3 A2
12 12
L
+ OFF
L
ON
24 - 60 V UC
t
S
3
(120A peak)
ON
t
Y2 Y3
L
RESET AUTO
+
Y1 Y2
L LS S CENTRAL
L
Stepping switch funct. S Central ON-OFF 120A special early make contact Output status Neon lamps by AC control (Push button illumination up to 40mA for glow lamps resp. LED’s)
OFF
LS
0,5 s - 60 min 10 A 250 V A (120A peak)
ON
B1
L
30 s-60min 10 A 250 V A (120A peak) L LS S
Function (Page✹) /Triggering AL4 AL4C
• • • • •
40 mA
MAX MIN
and otheres:
www.comat.ch
Power Step-on Step-off Relay
• Two-way lighting control on-off, stepping switch • 120A special early make contact • AC supply for glow lamp • 30s-1h running time, infinitely adjustable • subsequent time operation from zero • Manual ON
RESET AUTO
Time Range
Staircase Lighting Timers
• Two-way lighting control on-off, stepping switch • 120A special early make contact • AC supply for glow lamp • 30s-1h running time, infinitely adjustable • subsequent time operation from zero • Manual ON
ON
2500V 1500V
Tamb. operation/storage: -20..+60 / - 40..+85°C
Staircase Lighting Timers
40 mA
Test voltage:
AL5
40 mA
• Trigger status indication • Electronic switch position indication
AL4 C
Getrennter Steuerkreis. (Spannung wie A1-A2)
AL4 Staircase Lighting Timers
Installation Relays
E 120 A P
N N
2000W
N
2000W
N
N
2000W
Data at Tamb =20°C
Contact material Switching power AC1 // DC1 Peak inrush current Switching cycles mech./elec. (AC1)
W+AgSnO2 2200VA // ≤ 440W (DC) 120A /20ms 3x 10 7
W+AgSnO2 2200VA // ≤ 440W (DC) 120A /20ms 3x 10 7
W+AgSnO2 2200VA // ≤ 440W (DC) 120A /20ms 3x 10 7
Operating voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time Glow lamp load
0,85...1,1UN ≤ 2,5VA, 1,5W ≤ 60ms/≤ 300ms ≤ 40mA
0,85...1,1UN ≤ 2,5VA ≤ 60ms/≤ 300ms ≤ 40mA
0,85...1,1UN ≤ 2,5VA, 1,5W ≤ 60ms/≤ 300ms ≤ 40mA
AC 50/60Hz
UC 50/60Hz /
220-240, 110-127, 48-60 AL4/AC .... V 24 AL4/ UC .... V
220-240, 110-127 AL4C/AC .... V
230, 48-60 AL5/AC .... V 24 AL3/ UC .... V
Ordering example Staircase Lighting Timer AL4/AC220-240V ✹ Function Page: 52
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
109
KAT 2008
DIN RIC Miniature Contactor
Contactor 20 A
Contactor 25 A
2NO or 2NC or 1NO/1NC
Contactor 40 A
4NO or 4NC or 2NO/2NC
Contactor 63 A
4NO or 4NC or 2NO/2NC
AUX Block 2NO or 2NC or 1NO/1NC
4NO or 2NO/2NC
SE!
TS 35
NO NOI
AC/DC Istallation Contactors No noise! • All contacts doublemake/ doublebrake • Mechanical status display Test voltage: 4kV/3 Tamb. operation/storage: -20..+55/ - 30..+80°C
and others:
www.comat.ch
MAX MIN
RIC 20
RIC 25
RIC 40
RIC 63
RIC-AUX
Contactor 20 A
Contactor 25 A
Contactor 40 A
Contactor 63 A
Auxilary
Contactor with 2NO or 2NC or 1NO+1NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactor with 4NO or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
Contactblock with 2NO or 2NC or 1NO+1NC contacts. For signalling and control applications up to 6 A with crown twin contacts. For all RIC contactors.
20 A 400 V A
25 A 400 V A
40 A 400 V A
63 A 400 V A
6 A 400 V A
10mA 24V
10mA 24V
10mA 24V
10mA 24V
5mA 24V
1
A1
3
1
3
A1
5
7
1
3
A1
5
7
1
3
A1
5
7
51
61
Connection lay out (top/bottom) 2
A2
4
2
4
A2
6
8
2
4
A2
6
8
2
4
A2
6
8
52
62
1
A1
R1
1
R1
A1
R3
3
1
R1
A1
R3
3
1
R1
A1
R3
3
51
61
4
2
4
2
R2
A2
R4
4
52
62
2
A2
R2
2
R2
A2
R4
R2
A2
R4
R1
A1
R3
R1 R3
A1
R5 R7
R1 R3
A1
R5 R7
51 61
R2
A2
R4
R2 R4
A2
R6
R8
R2 R4
A2
R6
R8
52 62
Data at Tamb =20°C
Contact material Switching current I TH Switching voltage Switching power AC3 Switching power AC1/AC7a Op Frequenz max. cycle/hr Electrical life cycles AC1
AgNi 20A 400V 1,3kW/230V 4kW/230V 600 2x105
AgNi 25A 400V 2,2kW/400V 16kW/400V 600 2x105
AgSnO2 40A 400V 5,5kW/400V 26kW/400V 120 1x105
AgSnO2 63A 400V 8,5kW/230V 40kW/400V 120 1x105
AgNi 6A 400V – – 600 2x105
Coil voltage range Power consumption Operate / release time typ.
0,85 - 1,1 U N 2,5W 20ms // 20ms
0,85 - 1,1 U N 3W 10ms // 50ms
0,85 - 1,1 U N 5W 20ms // 35ms
0,85 - 1,1 U N 5W 20ms // 35ms
– – – // –
UC A 50/60 Hz / D
UC A 50/60 Hz / D
UC A 50/60 Hz / D
24, 230 RIC25-400/UC ..... V
24, 230 RIC40-400/UC ..... V
24, 230 RIC63-400/UC ..... V
RIC-AUX20
24, 230 RIC20-110/UC ..... V
24, 230 RIC25-220/UC ..... V
24, 230 RIC40-220/UC ..... V
24, 230 RIC63-220/UC ..... V
RIC-AUX11
24, 230 RIC20-020/UC ..... V
24, 230 RIC25-040/UC ..... V
24, 230 RIC40-040/UC ..... V
RIC-AUX02
RIC25-63
RIC25
RIC40 RIC63
RIC-AUX
45
RIC20
Installation contactor RIC25-400/UC230V
*Option Sealing cover Type: RIC-SEAL20 RIC-SEAL25 RIC-SEAL40-63
TS35
Ordering example
85
RIC20
24, 230 RIC20-200/UC ..... V
Aux block RIC-AUX20 Sealing cover RIC-SEAL20
1.5* 17,5
35
54.5
8
5
44 ( 45.5* )
16.5
✹ Function Page: 52
110
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Monitoring Relays
Monitoring Relays
4
• Voltage Monitoring • Current Monitoring • Mains Monitoring • Isolation Monitoring • Thermo Protection Relay
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
111
KAT 2008
Voltage Monitoring
Pa ge
Co nta c
et So ck
Se rie s
t
Monitoring Relays
Undervoltage Monitor
MV52
DIN 35
6 A 114
Undervoltage Monitor
MV62
DIN 35
6 A 114
Overvoltage and Undervoltage Monitor
MV53
DIN 35
6 A 115
DC Voltage Monitor
CT524
AC or DC Voltage Monitor
CUEBU
Precision DC Voltage Monitor
SSU2...
6 A 116 DIN 35
8 A 117 5 A 118
(SSU11)
RMS Precision AC/DC Voltage Monitor
Current Monitoring
EOCR-AR DIN 35
3 A 120
Undervoltage Monitor
EUCR-BR DIN 35
3 A 120
ECR-3D
DIN 35
3 A 120
SRCT-35 DIN 35
122
Current Transformer
Isolation Monitoring
5 A 118
Overvoltage Monitor
Overvoltage and Undervoltage Monitor
Mains Monitoring
SSU7...
DC Current Monitor (200 mA)
CT512
6A 123
DC Current Monitor (2 A)
CT515
6 A 123
DC Current Monitor (6A)
CT516
6 A 123
AC or DC Current Monitor
CUEBI
Three-phase Monitor (50 Hz)
SSU33
Three-phase Monitor (50 Hz)
SSU34
DIN 35
5 A 127
Three-phase Monitor (60 Hz)
SSU36
DIN 35
5 A 127
Phase-sequence Monitor
SSU31
Isolation Monitor
ESU-D2
DIN 35
8 A 124
6 A 126
6 A 128
DIN 35
5 A 130 5A
Thermo Protection Relay
Motor Thermo Protection Relay
TSR19
5A 132 5A
112
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Monitoring Relays
Monitoring Relays
Voltage Monitoring
4
DIN
11
V
V
V
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
113
KAT 2008
Undervoltage Monitor
V
MV 52 (50Hz) MV 62 (60Hz)
11
14
al ok 12 12
A2
A1
Zu schützende Anlageteile Installation à protéger Installation to be protected
and otheres: www.comat.ch
L N
13mm MV52 (50Hz), MV62 (60Hz) U SET (V)
VA t
supply
t
14
gn
11
gn
ok
12
ok
ye
rd
fail
al
rd
The MV52 (50Hz) or MV62 (60Hz) protects control systems, contactors and motors during undervoltage against thermal overload and malfunctions. The monitoring can be set precisely in volts from U N – 30% up to U N. The switching off or on again follows delayed by 0,1/0,5 or 1second. 2 LEDs show the definite monitoring status.
alarm
V
Data at Tamb. = 20°C
Setting range Hysteresis t (fail-al-ok)
0,7 (– 30%) U N ...U N 5% 0,1/0,5/1s
Switching current/voltage Switch rating Mechanical switching cycles
6A 250VA 1500VA/...180W 30x10 6
Voltage tolerance Power consumption Ambient temperature
... U N +15% 3,5VA,1W (–25)–10...+60°C
BS13-K BS13-G
90
45
TS35
(incl.paper)
Order-Nr.
50 Hz 11
114
44
KAT 2008
13
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
MV52 /AC 230 V MV52 /AC115 V
60 Hz
Accessories Label (5Piece) Label (5Piece)
BS13-G BS13-K
MV62 /AC120 V
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Overvoltage and Undervoltage Monitor
V
MV 53
and otheres: www.comat.ch
+ 2,5% + 5 % + 7,5 % +10 % +12,5% +15 % +17,5 %
12 11 14 230V 115 V
236V 118 V
241V 121V
247V 124 V
253V 127 V
258V 129 V
265V 132 V
270V 135 V
30%
35%
al
ok
Alarm threshold value 0%
5%
10 %
15 %
20%
25%
A2 A2 A1 230V 115 V
219 V 109 V
207V 103 V
195 V 97V
184 V 92V
173 V 86V
161V 80V
150 V 74V
Zu schützende Anlageteile Installation à protéger Installation to be protected
+ 0%
L N
Never set both thresholds on 0 % !
The MV53 (50/60Hz) protects single phase consumers in AC networks from over- and undervoltage. Overvoltage and undervoltage thresholds can be set independently in percentage of the nominal voltage using two DIP-switches (see diagram above). Using a potentiometer allows setting an alarm delay of 25ms...2,5s. A two-colored LED shows the definite monitoring status.
V NOM
ok
ye
al fail
tR
ok
ok
12 gn
tO
tR
rd
al
4
alarm
V
U Nom + 2,5...17,5% U Nom – 35...– 5% 2,5% 25ms...2,5sec 70ms
Switching current/voltage Switch rating Mechanical switching cycles
6A 250VA 1750VA/...170W 2x10 7
Voltage tolerance Power consumption Ambient temperature
U N – 35%... +17,5% 3,5VA,2W (–25)–10...+60°C
65
32
90
Data at Tamb. = 20°C
Setting range overvoltage Setting range undervoltage Hysteresis t O Alarm delay t R Reset time
4
TS35
t O : Alarm delay t R : Reset time
987
14
11
tO
10
supply
HYST.
1
V U2 V U1
Monitoring Relays
MV53 HYST.
V O1 V O2
2
Order-Nr. 50/60 Hz
70
22,5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
MV53 /AC 230 V MV53 /AC115 V
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
115
KAT 2008
V
DC Voltage Monitor
CT 524
and otheres: www.comat.ch
Socket C12B0
Relay C32/DC24V
Type CT524.2/DC24V
Module CT524/DC24V
CT524 Economy DC Voltage Monitoring Relay
1
with 3 twin changeover contacts. 4 functions can be selected: Overvoltage/undervoltage monitoring with adjustable hysteresis or 2 range monitors (INT or EXT). Adjustable alarm delay. LED display for errors and ok. Contact inspection window at the top. Manual safety operation.
[V]
supply
MAX
t R fail
t
+
ok
R
R 2 10
tR
t
R
A2
t
tR
t
ok al
EXT
t
tR
R
t
fail ok al
ok
ye
fail
rd
1 12 2
V in
Input resistance 12 ➞10: 100k
+
DC24V
+
t
Data at Tamb. = 20°C
Alarm delay t Reset time t R
0,1/0,5/2s 100ms
Switching current/voltage Switch rating Mechanical switching cycles
6A 250V A 1500VA/...200W 100 x10 6
Voltage tolerance Power consumption Ambient temperature
0,8 -1,2UN ≤ 0,5W –25...+60°C
t R fail
R
tR
6
fail ok al
INT
CT B1 A1
10 11
al
MIN
gn
9 8 7 5 3 4
2
alarm
Order no.
Accessories
Socket Range
U max
0-30 V
40 V
C12 B0
≤ 10%
CT 524.2 / DC24 V
Type No. = Module + Relay (FS-C, HF-32 incl.) Socket and Accessories: Page 97
116
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
V
V
Voltage Monitoring AC or DC
CUEBU
and otheres: www.comat.ch
L N (+)
1
U
AC230V 50/60Hz Pv 4VA Input 5-9
5
9
AC 15 ...480 V DC 15 ...700 V Ri 1M
10
8A 250VA
Monitoring Relays
2 4 6
CUEBU 15 -700
Functions Up Hys
[V] Up
fail
t1
ok al M
R Supply
Monitoring Relay for AC or DC voltages ranging from AC15...480V, DC15...700V. LCD display for the measured value and the parameter setting. LED indication for the alarm status. Snap on to DIN-rail TS35 conform DIN (43880).
[V] Hys
4
Lo Lo
fail
t1
ok al M
R Supply
Up [V] Lo
Hys Up / Lo
t1
t1
ok al M
R Supply
gn
ok
fail
ye
fail
rd
alarm
V
Monitoring range Hysteresis Input resistance Ri Display/Accuracy
Data at Tamb. = 20°C
AC15...480V, DC15...700V 5...50% 1M xxxV/2% ±1digit
t Alarm delay time t1
0,1...12s
Switching current/voltage Switching power AC1 Output contact
8A 250V AC1 /...240W 2000VA /...240W 1x u, AgNi
Operation voltage AC50/60Hz Power consumption Pmax Isolation Temperature: operating/storage
AC230V +10%; -15% 50/60Hz 4,5VA/2,5W 3kV rms /1min -20...+55°C /-40...+70°C
Order-Nr. 50/60 Hz
CUEBU15-700 / AC 230 V
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
117
KAT 2008
V
V
Precision DC/RMS Voltage Monitoring Relay
SSU11 /... SSU2x /... SSU7x /...
and otheres: www.comat.ch
+
RL
9 8 7 5 3 4
Um
()
10 11
50mA
DC 10-32V
(+)
6 1 2
L+ N
35 mm
FAIL OK
U SET U SET
OK FAIL
supply
U SET U SET
t ok
supply ➞3s: + LEDs
t fail
11
gn
normal fail delay alarm
The SSS11, SSU2x and SSU7x are high precision voltage monitoring relays for DC or RMS AC/DC with interactive front operation and display of values and voltmeter function. Two values for FAIL and OK can be programmed. With this, the hysteresis is automatically given. Depending of the programmed values the over- or undervoltage monitoring function is defined. Fixed max. and min. values are given for alarm triggering. However, the min. value monitoring can be disabled. The measuring input is galvanically isolated from the power supply (2-10). High EMC immunity design and self diagnostic features guarantee very high reliability and a long service life. Applications are for example monitoring of battery voltage in industrial installations.
ok al
9 8
ok
SSU11/...; SSU2x/...; SSU7x/...
ye
meas.
rd
alarm
Selection of type For DC measurement
Type SSU 2x / UC...V
For RMS AC/DC
SSU 7x / UC...V
F Measurement range (x) Measurment range Adjustment range Resolution t fail, t ok
9
2
0 - 210mV 0,1 - 200mV 0,5mV
0 - 38V 0,1 - 35V 20mV
3
4
0 - 38V 0 - 77V 0,1 - 10V 10 - 75V 20mV 100mV 0,1s - 600s
5
6
0 - 157V 40 - 150V 100mV
0 - 285V 0*/50 - 270V 0,5V *SSU76
Power supply Power supply tolerance Ambient temp
UC110-240VU -20% +10%
Switching current/voltage
1 x co 5A, 250 V; 1 x no Transistor NPN, DC50mA, 24V
UC60-127VU UC24-48VU -20% +26% -20% +55% +10...+50°C (-25...+60°C)
Example of order SSU DC 0-38V/UC24-48V: SSU23/UC24-48V SSU RMS AC/DC 0-200mV/UC110-240V: SSU79/UC110-240V
UC12-15VU -25% +33%
Accessories Socket: Retaining clip:
C11-A HF-24 Frontpanel mounting: FZ-23
Attention: P/O numbers of several devices were changed (refer below). Devices are identical. Old number: SSU11/UC110-240V SSU11/UC60-127V SSU11/UC24-48V SSU11/UC12-15V
Replaced by: SSU26/UC110-240V SSU25/UC60-127V SSU24/UC24-48V SSU23/UC12-15V
Old number: SSU12/...V SSU13/...V SSU14/...V SSU16/...V
Replaced by: SSU22/...V SSU23/...V SSU24/...V SSU26/...V
Socket and Accessories: Page 97
118
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Monitoring Relays
Monitoring Relays
Current Monitoring
4
DIN
11
A
A
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
119
KAT 2008
Current Monitoring Relays
A
EOCR-AR -05 -30 EUCR-BR -60
and otheres: www.comat.ch
1
1
OP JUST LO
LOAD 2
2
IT
Setting ranges 1x
[A]
2x
3x
4x
5x
-05 0,5-6 0,25-3 0,17-2 0,13-1,5 0,1-1,2 -30 2,5-30 1,25-15 0,83-10 0,62-7,5 0,5-6 -60 5-60 2,5-30 1,7-20 1,25-15 1-12
EOCR-AR
A
EUCR-BR
A tO
tO
tR
1/2
supply
al
L (+) U B N
SCHÜTZ CONTACTOR
15
ok al
18 16 gn
EOCR-AR / EUCR-BR 1 fail
or
2 fail
= FAIL
The EOCR-AR and the EUCR-BR monitor overcurrent and undercurrent on AC power circuits. One or two current paths can be monitored directly up to 60(75)A, by means of the integrated current loop transformers. The adjustable alarm delay ( t O) and the automatic alarm resetting ( t R) permit universal usage in motor and transformer protection systems, monitoring of electrical heating elements and in the control of pumps, ventilation systems, suction and feed devices. The nominal monitoring range in the 3 types -05/-30/-60 can be altered by multiple looping of the conductor (see schedule above).
1
1
2
ok
ye
fail
rd
alarm
al ok
+
A2 A1 15 16 18
+L N
2
t
Data at Tamb. = 20°C
Alarm delay t O Reset time t R
0,3 - 30s 0,5 - 150s
Switching current/voltage Switch rating Mechanical switching cycles
3A 250VA 750VA/...90W 20x10 6
Voltage tolerance AC/UC Power consumption Ambient temperature
0,8-1,1/1,25 U N 3(5) VA /1W –20...+60°C
16
Order-Nr. 10
AC
10
20
05 30 60
A1
15
16
05 30 60
Over current relay
EOCR-AR- ... / AC 230 V EOCR-AR- ... / AC115 V
EOCR-AR- ... / UC 24 V
Under current relay
EUCR-BR- ... / AC 230 V EUCR-BR- ... / AC115 V
EUCR-BR- ... / UC 24 V
18
24
A2
UC (AC/DC)
50/60 Hz
62
120
KAT 2008
54
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Current Monitoring Relays
A
-05 -60
ECR-3D
and otheres: www.comat.ch
Setting ranges
L2
1x
[A]
2x
3x
4x
5x
-05 0,5-6,5 0,25 - 3,2 0,17- 2,1 0,13-1,63 0,1-1,3 -60 5-75 2,5-38 1,7-25 1,25-18,8 1-15
L3
L1 or L 2 or L 3 0
A
U
A
Phase sequence error
tO
R2 L U B (+) N
15
18 16
25
28 26
0
tO tR
supply
R1
L1+L 2 +L 3 off
tR
gn
ok
ye
fail
rd
alarm
Monitoring Relays
L1
ECR-3D 1 fail
or
2 fail
or
3 fail
= FAIL
The ECR-3D is for monitoring overcurrent and undercurrent on AC power circuits. Three current paths of up to 60(75)A can be monitored directly by means of the inte-grated current loop transformers. The adjustable alarm delay ( tO) and the automatic alarm resetting ( tR) permit universal usage in automation and protection techniques. The set values are displayed automatically by setting the respective parameters. Triggered faults remain stored and displayed until reset.
1
1
R2 al ok
+
R1 al ok
A2 A1 26 25 28 16 15 18
+L N
4
2
2
( L1)
( L2)
( L3)
Data at Tamb. = 20°C
0,3 - 30s 1,0 - 120s /
Switching current/voltage Switch rating Mechanical switching cycles
3A 250VA 750VA/...90W 20x10 6
Voltage tolerance AC/UC Power consumption Ambient temperature
0,8-1,1/1,25 U N 3(5) VA /1,5W –20...+60°C
16
3
t Alarm delay t O Reset time t R
10
10
10
30
21
Order-Nr.
UC (AC/DC) 05 60
A2 A1 26 25 28 16 15 18
71
5
5
Current monitoring relays
ECR-3D-... / UC110-240 V ECR-3D-... / UC 24 V
70
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
121
KAT 2008
Current Transformers
SRCT-35 - 50/ 5 A - 100/ 5A - 250/ 5A - 500/ 5A
and otheres: www.comat.ch
SRCT-35 Current transformers of the SRCT-35 series transform high AC currents into proportional secondary current in the ratio 10:1 (type -50) up to 100:1 (type -500). With accuracy class 1, coupled with a large power reserve (PN: 2,5VA) and high overload capacity up to 150%, the SRCT-35 is the ideal transformer for general applications and for the use with Comat monitoring relays ..AR, ..BR, ..3D.
2,5VA Class 1 50/60Hz
Operating voltage Overload Ambient temperature
720V x 1,5 (Class 1,5) –5...+40°C
10
Power Accuracy Frequence range
BEF 1 k
Order-Nr.
Direct mounting
35
86
K
40
38
UC (AC/DC) FOR M4
50 100 250 500 1)
3
ø 4.3
4,5
SRCT-35 - ... / 5 A 50
122
KAT 2008
76
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
2
65
1) Other primary currents on request
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
A
DC Current Monitor
CT 512 CT 515 CT 516
and otheres: www.comat.ch
(200 mA) (2 A) (6 A)
Socket C12B0
Relay C32/DC24V
Type CT512.2/DC24V
Monitoring Relays
Module CT512/DC24V
CT512,515,516 2
Economy DC Current Monitoring Relay
1
with 3 twin changeover contacts. Without external shunt up to 6A. 4 functions can be selected: - Overcurrent/undercurrent monitoring with adjustable hysteresis or 2 range monitors (INT or EXT). - Adjustable alarm delay. - LED display for error and ok. Contact inspection window at the top. Manual safety operation.
[A]
supply
MAX
t R fail
t
+
ok
R
tR
t
R
t
tR
t
ok al
EXT
t
tR
R
t
fail ok al
ok
ye
fail
rd
A2
10 11
6
RL
1 12 2 in
+
Voltage drop (2-12) CT512 : ≤ 300mV CT515 : ≤ 200mV CT516 : ≤ 100mV
4
t
Data at Tamb. = 20°C
Alarm delay t Reset time t R
0,1/0,5/2s 100ms
Switching current/voltage Switch rating Mechanical switching cycles
6A 250VA 1500VA/...200W 100 x10 6
Voltage tolerance Power consumption Ambient temperature
0,8 -1,2UN ≤ 0,5W –25...+60°C
t R fail
R
tR
CT B1 A1
fail ok al
INT
2 10
DC24V
al
MIN
gn
9 8 7 5 3 4
R
alarm
Order no.
Accessories
Socket Range
0-200 mA 0-2 A 0-6 A
max
300 mA 3A 7A
C12 B0
≤ 10%
CT 512.2 / DC 24 V CT 515.2 / DC 24 V CT 516.2 / DC 24 V
Type No. = Module + Relay (FS-C, HF-32 incl.) Socket and Accessories: Page 97
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
123
KAT 2008
A
Current Monitoring AC or DC
A
CUEBI
and otheres: www.comat.ch
L N (+)
1
AC230V 50/60Hz Pv 4VA Input 5-9
U
5
9
AC 0,1A ...10 A DC 0,1A ...10 A Imax.15A Ri 5m
2 4 6
10 8A 250VA
CUEBI01-10
Functions Up Hys
[A] Up
fail
t1
t2
ok al M
R Supply
Monitoring Relay for AC or DC currents ranging from 0,1A up to 10A with start-up delay. LCD display for the measured value and the parameter setting. LED indication for the alarm status. Snap on to DIN-rail TS35 conform DIN (43880).
[A] Hys
Lo Lo
t2
fail
t1
Supply
ok al M
Hys
Up [A] Lo
R
Up / Lo
t2
t1
t1
ok al M
R Supply
gn
ok
fail
ye
fail
rd
alarm
A
Monitoring range Hysteresis Input resistance Ri Display/Accuracy
Data at Tamb. = 20°C
AC/DC 0,1...10A 5...50% 5m xx,xA/2% ±1digit
t Alarm delay time t1 Start-up delay t 2
0,1...12s 0,1...20s
Switching current/voltage Switching power AC1 Output contact
8A 250V AC1 2000VA /...240W 1x u, AgNi
Operation voltage AC50/60Hz Power consumption P max Isolation Temperature: operating / storage
AC230V +10%; -15% 50/60Hz 4,5VA/2,5W 3kV rms /1min -20...+55°C /-40...+70°C
Order-Nr. 50/60 Hz
CUEBI 01-10 / AC 230 V
124
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Monitoring Relays
Monitoring Relays
Mains Monitoring
4
DIN
3
11
3
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
125
KAT 2008
Three-phase Monitoring Relay
3
SSU33 (50Hz)
and otheres: www.comat.ch
230V ( )
< 10
MIN
1)
2)
400V ( )
>
U
µ 6 A 250 VA 1500 VA/ ...270 W
1)
L1 L2 L3 N
MAX 1
0,2 - 5 s
FIX
ok
al
t del
2) 2
11
∆ U, ϕ, ƒ
9 2
PHASE SEQUENCE
fail red SSU33L
ok
alarm
gn 7 4 5
In case of a power failure the alarm is activated without delay!
SSU33L The SSU33 (50Hz) provides comprehensive monitoring of three-phase mains supplies with or without neutral. The following mains faults are monitored: Error signal 1 U (V , V ): Exceeding or dropping below the fixed voltage values Umin/Umax for L1-N or L1-L2 (no differential voltage, phase position or frequency fault). Error signal 2 ∆ U, ∆ ϕ, ∆ ƒ: One or more of the three voltages, phase positions, phase sequence or the mains frequency are diverging from the required value. Depending on the nature of their occurrence ∆-errors are evaluated cumulatively. Any error is signalled by the red LED and is reported after expiry of the set alarmdelay time ( t del 0,2...5s) via 7-4-5. In the correct status (ok) the green LED is illuminated (4-5 open, 4-7 closed).
U
3x230 (400) V
3x400V
1)
2)
L1 N L2 L3
L1 L2 L3
Overvoltage > (U max)
U U
> 275V —
— > 480V
Undervoltage
< (U min)
U U
<160V —
< 280V
Differential range
∆U ∆U
20 - 100V 35 - 173V 3-15°/3-15Hz
20 - 100V 35 - 173V 3-15°/3-15Hz
SSU33L/AC230V
SSU33L/AC400V
1
∆ 2
∆ ϕ /ƒ
75
Order no.
—
Accessories Socket Retaining clip Front mounting
C11A
C11A HF-24 FZ-23
38
Socket and Accessories: Page 97
126
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Three-phase Monitoring Relay
3
SSU34 (50Hz) SSU36 (60Hz)
and otheres: www.comat.ch
DO NOT connect simultaneously: neutral conductor N and bridge L3-L!
MIN
>
U
SSU34/36
MAX 1
oder or
t del L
2
0,2 - 5 s
ok
al
fail
∆ U, ϕ, ƒ
L3 L2 L1
µ 5A 250VA 1250 VA/ ...150 W
< N
red PHASE SEQUENCE
ok
gn
alarm
3
4 5 6 3 7 8
In case of power failure the alarm is activated without delay!
NG
ITORI N O M S
U
Monitoring Relays
SSU34, SSU36
MAIN
E The SSU34 (50Hz) and the SSU36 (60Hz) provide comprehensive monitoring of three-phase mains supplies with or without neutral. The following mains faults are moni-tored: Error signal 1 U (V , V ): Exceeding or dropping below the set voltage values Umin/Umax for L1-N or L1-L3,L (no differential voltage, phase position or frequency fault). Error signal 2 ∆ U, ∆ ϕ, ∆ ƒ: One or more of the three voltages, phase positions, or the mains frequency are diverging from the required value. Depending on the nature of their occurrence ∆errors are evaluated cumulatively. Error signal 3 : Connection polarity reversal (wrong phase-sequence). Any error is signalled by the red LED "fail" and is reported after expiry of the set alarm-delay time ( t del 0,2...5s) (for error signal 3 undelayed) via 5-6 and 7-8. In the correct status (ok) the green LED is illuminated (5-6 and 7-8 open, 5-4 and 7-2 closed).
4
50Hz
50Hz
50Hz
60Hz
60Hz
60Hz
230/400VA 235-275V 410-480V
290/500VA 300-350V 520-600V
120/208VA 125-145V 216-250V
265/460VA 270-320V 470-550V
277/480VA 284-232V 490-575V
Overvoltage > (U max)
U U
58/100VA 60-70V 105-121V
Undervoltage < (U min)
U U
40-55V 70-95V
160-225V 280-390V
200-280V 350-485V
85-115V 148-200V
185-260V 322-450V
194-270V 336-470V
Differential range
∆U ∆U
5-25V 10-50V 3-15°/3-15Hz
20-100V 35-173V 3-15°/3-15Hz
20-100V 35-173V 3-15°/3-15Hz
10-50V 17-87V 5-24°/3-22Hz
20-100V 35-173V 4-21°/ 3-19Hz
20-100V 35-173V 4-21°/ 3-19Hz
SSU34/AC100V
SSU34 /AC400V
SSU34/AC 500V
SSU36/AC208V
SSU36 /AC 460V
SSU36 /AC480 V
1
∆ 2
∆ ϕ /ƒ Order no.
75
Detachable Terminals
105
5
50
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
127
KAT 2008
Phase-sequence Monitoring Relay
3
SSU31
and otheres: www.comat.ch
L1 L2 L3 Failure of L2 or L3 cannot be displayed (LED)!
SSU31 U 50ms
200ms
supply 7
gn
4
ok
5 gn
ok
ye
fail
rd
al
rd
The SSU31 serves as a phase-sequence, three-phase undervoltage and phase failure monitor. The monitoring function helps to ensure the correct rotation direction of pumps, motors and conveyors in mobile devices with connection to different power outlets. The defined undervoltage and phase failure protects against malfunction and damage caused by overheating.
alarm
9 8 7 5 3 4
ok 10 11
al 6 1 2 L1 L2 L3
Data at Tamb. = 20°C
Supply Cut-off undervoltage Hysteresis Power consumption
...1,2 . U N U N –20% 3% / U N 10VA / ≤ 1,5W
Switching current/voltage Switch rating AC1/DC1 Mechanical switching cycles
6A 250VA 1500VA/...200W 30x10 6
Order no. 50/60 Hz
SSU31/AC 400 V SSU31/AC 208 V
Accessories Relay socket Retaining clip Front mounting
C11A HF-24 FZ-23
Socket and Accessories: Page 97
128
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Monitoring Relays
Monitoring Relays
Isolation Monitoring
4
DIN
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
129
KAT 2008
Isolation Monitor
ESU-D2
and otheres: www.comat.ch
ESU-D2
R MAX
30k
(AL1) R SET
supply
(AL2) R MIN
Output AL1 15 contacts
AL2
(37)
25
LEDs
gn
t del
t del
tR
tR
1s
1s
4k (Fix)
18 16 (38)
28 26
ok
ok 4k
ye Scale 30k
al
Trend
+
al
rd gn
ok
ye
meas.
rd
alarm
ESU-D2 The ESU-D2 monitors the isolation resistance in non-grounded DC-networks (24-48VD). Two alarm steps (prealarm AL1 and main alarm AL2) are indicated via separate output contacts. Settable alarm delay ( tdel): 0,1-10sec. Displays: bargraph-display of the measured earthing resistance 4...30k (green = ok). Two red LEDs show the ground tendency towards plus (+) or minus ( ). Measuring terminal 5V for the external display of the earthing resistance (0,1V/k ). Test functions: Periodic automatic check, also with key “Test”. Environmental failures: monitoring of AC-short circuit, overvoltage, ground interruption.
+
Zu überwachende Anlage Installation à surveiller Installation to be monitored
DC 0..52V
E 0,1V/k
V
+
E2
Data at Tamb. = 20°C
Measuring range Error of measurement Setting range AL1/AL2 Time of error-detection Alarm delay time settable Voltage stability + or–/earth
+ 0,1V/k
1k...50k / 0...52VDC ≤10% 4-30k / 4k fix ≤ 800ms / 30k 0,1-10s AC250V
Switching current/voltage Switch rating Mechanical switching cycles
5A 250VA 1250VA/...150W 5x10 6
Voltage tolerance AC/UC Power consumption Ambient temperature
U N ±15% / U N ± 20% 2W (–25) 0...50 (60)°C
Pre alarm
AL1
5V
ESU-D2
15 16 18
AL1
(1mA 12V ) 5A 250VA
AL2 N
L E1 25 26 28 37 38
L (+) UB N
AL2 Main alarm
Connect E1, E2 separately on E.
Only one ESU-D2 per DC network!
75
Detachable Terminals
Order no.
UC (AC/DC)
105
130
KAT 2008
5
50
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
ESU-D2 / UC110-240 V ESU-D2 / UC 24-48 V
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Monitoring Relays
Monitoring Relays
Thermo Protection Relays
4 C
11
M
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
131
KAT 2008
Thermo Protection Relay
C
TSR19
M
and otheres: www.comat.ch
or
2
1
TSR 19 R PTC /
fail
-SWITCH
The TSR19 is intended to monitor the temperature of motor coils, generators and transfomers. It detects the temperature of the windings over the change in resistance of the PTC thermistors 1 or the position of the thermo switches 2 . The circuit is designed to detect a break in the continuity of the detection circuit and ground failures. On position “PTC”, line or sensor fault is also detected. Reset after failure detection: Press reset button or interrupt supply voltage for >200ms.
°C/F 2,5s
supply
gn
1-3
ok
11-9 gn
ok
RESET
ye
fail
al
rd
rd
alarm
1
PTC
2
Thermo Switch
Sensor
9 8 7 5 3 4
al
ok
A2
10 11
A1
6 1 2
+
Data at Tamb. = 20°C
100..1800 ; 0..1800 20 R fail >2200 15V / R sens ∞ ≤ 3mA
Switching current/voltage Switch rating Mechanical switching cycles
5A 250VA 1250VA/...180W 30x10 6
Voltage tolerance Power consumption Ambient temperature
–15/+10% ≤ 5VA –25...+60°C
75
Sensor resistance R ok Sensor wire R max Error-detection R fail Sensor supply U 5-7 Sensor supply 5max
Order no.
Accessories
UC(AC/DC) 50/60 Hz
TSR19 /AC 230 V TSR19 /AC115 V C11A
38
TSR19 / UC 24 -48 V
Socket C11A Retaining clip HF-24 Frontpanel mounting: HF-23
The TSR19 replaces the types TSR17 and TSR18.
Socket and Accessories: Page 97
132
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
SMS Relay / Comat BoxX
SMS Relay / Comat BoxX
5 • SMS Relay • Miniature Controller, Comat BoxX
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
133
KAT 2008
Notes
134
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Automation Products
SMS Relay / Comat BoxX
SMS Relays
5 • Monitoring of all inputs and outputs with SMS messaging • Remote control of outputs by SMS • Sequential alert messaging to 5 different subscribers • Easy configuration with PC and «FAST SMS SET»-up configuration software • Power failure notification by SMS messaging • Status change messages by SMS • User defined message text
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
135
KAT 2008
Applications
CMS -10
SMS Relay
Monitoring Alerting, Controlling Alerting Controlling Monitoring Controlling Monitoring Alerting
136
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Configuration software
CMS-10
Technical Data’s
SMS Relay / Comat BoxX
SMS Relay
Operating voltage
AC 110 -240 VA 50 /60 Hz
DC 12- 48 VD
Power consumption
8 VA / 6 W
6W
Switching capacity
4x 10 A 250 V
Temperature range
Tu: -25 ...+55° C Rel. humidity: 5 ...95 % (non condensing) Protection IP 20
Inputs
6 x digital trigger level 85 Va
Outputs
4 x CO contacts
Provider (Phone/ Network)
User selectable (dependent on SIM card)
max. 10 %
5 6 x digital trigger level 9,5 Vd
Antenne
Dimensions
Installation according to DIN 43 880 COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
137
KAT 2008
CMS -10 SMS Relay
Order-Nr. Type
Description
CMS -10 /AC110-240 V
SMS Relay AC 110 -240 V Base unit only with small antenna (CMS-ANT)
CMS -10 /DC12-48V
SMS Relay DC 12-48 V Base unit only with small antenna (CMS-ANT)
KIT consisting of: A base unit with small antenna, antenna with magnetic pod and 2.5 m cable, programming cable, USB-RS232 Interface connector, CD with «FAST SMS SET»-up programming software and operation manual CMS -10 KIT /AC110-240 V
Installation kit complete (SMS Relay AC110 -240V)
CMS-10 KIT/DC12-48V
Installation kit complete (SMS Relay DC12- 48 V)
Accessories CMS -RS 232
SMS Relay Programming Cable RS232
CMS -USB
USB-RS232 Interface connector (including driver CD)
CMS -ANT
Small spare antenna for base unit, 63 mm long
CMS -ANT -MAG / 2.5 M
Antenna with magnetic pod and 2.5 m antenna cable
CMS -ANT -SPEZ / 5 M
External antenna with 5 m antenna cable
CMS -ANT -KAB /5M
Antenna cable 5m (extension)
CMS -ANT -KAB /10 M
Antenna cable 10 m (extension)
CMS -ANT -ADAPT
Adaptor FME to SMA plug
CMS -CAP
Device cover (spare)
CMS -CD
CD with FAST SMS SET -up programming software and manual
Installation note Antenna with magnetic pod and 2.5 m antenna cable.
The Base unit device is delivered fully operational and includes the small aerial CMS-ANT.
Type: CMS-ANT-MAG/2.5M
For installation inside a control panel, the small device aerial may not be suitable and needs to be replaced by the antenna with magnetic pod (CMS-ANT-MAG/2.5M) or by the external antenna (CMS-ANT-SPEZ/5M).
Before installation, the final location of installation must be taken into consideration.
These two antennae provide considerably better results and improve communication with the mobile network. Please ask our product specialists if you require any support.
External antenna with 5 m antenna cable Type: CMS-ANT-SPEZ /5M
138
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Automation Product
The speaking controller PC NET DC 24VD or
1 2
3
4
0-10V
5
DC12-24VD
6
+
SMS Relay / Comat BoxX
DC 24VD
+ +
BoxX
BoxX
ESC
POW REC
+ OK VOL
MIC DISPLAY UNIT LCD
TYPE: AF-10MR-D-..... /DC24VD
1
Q
2
REL
VOICE & REMOTE UNIT
3
8A 250V
4 PC
AF-MUL/DC12-24VD
1 2 EXT SPK
3 4 WAV
5
PC
• Programming via PC • Remote controlling and voice message over telephone network or Cellular phone • Remote maintenance and remote operation of the installation • Comprehensive function block library • Password protected
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
139
KAT 2008
BoxX
127
The Controller
Function blocks Intermediate relays Timer instructions
• Program storage 64 kByte • Time range 0,01s - 99,99 h • Counting values 1- 999’999 (up to the year 2099) • System timer back up 100 h
Voice module AF-MUL for 98 messages
6 / 12 Inputs
PC
digital / analog
NET
(total max 8 min)
Type “CAP”
Type “LCD”
DC 24VD
DC 24VD or
+ +
1 2
3
4
0-10V
5
AC110 -240 V A
6
L
N
N
BoxX
1 2
3
4
5
AC110-240VA
6
N
L
BoxX
BoxX
ESC
POW REC
+ OK VOL
MIC CAP
COVER
TYPE: AF-10MT-GD-..... /DC24VD
+1
Q
DISPLAY UNIT LCD
TYPE: AF-10MR-A-..... /AC110-240VA
+ 2 PNP + 3 2A + 4 24VD
1
Q
2
4 / 8 Outputs Relay / Transistor
140
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
REL
3
VOICE & REMOTE UNIT
8A 250V
4 PC
AF-MUL/AC110-240VA
1 2 EXT SPK
3 4 WAV
active
PC
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
BoxX
The Application The Comat BoxX can be programmed by PC or with the snap-on LCD display with integrated function keys. It is possible to modify time intervals of the function blocks in the existing control program on site directly on to the installation. The LCD display can be connected to the Comat BoxX to visualize conditions or may be removed (without voltage) and used on another Comat BoxX.
°C
ESC
Analogue inputs
OK
Setting the display
5
0
4
0
3
0
2
0
1
0
0
0
1
0
2
0
SMS Relay / Comat BoxX
BoxX
The 24 V versions of the Comat BoxX can also process analogue signals 0...10 V with increments of 0.1V . All inputs can be used or configured at random as analogue or digital inputs. Function blocks for the comparison of analogue values are available, i.e. to monitor temperature in a heating system.
DISPLAY UNIT LCD
Programming software
Programming the function blocks
The voice and remote module
The programming software QUICK II allows easy and transparent programming of the Comat BoxX with a PC. QUICK II is based on Windows ®. 127 function blocks can be stored inside the program memory of the Comat BoxX. Stored programs cannot be lost even during a power loss. Therefore back up batteries are not needed. With the simulation tool, the set up can be tested on the PC before commissioning. Example: Page 4
Control tasks can be solved easily with the function blocks available in the library. Programming codes in a high-level program language are not required. Simply place the corresponding function blocks and link them with other function blocks according to the required control function.
The voice module allows the playing of messages through either the built-in or external loud speakers. The voice module also replays phone calls or dials phone numbers to send emergency or status messages. Messages are recorded directly over the built-in microphone or are transferred as *.wav files directly from the PC.
5
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
141
KAT 2008
BoxX
Programming software Quick II
Example: Programing environment
142
KAT 2008
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
BoxX
The Extension module
Recording of messages with the PC
Programming via the MUL voice and remote unit
NET
AF-BC
AF-MUL
AF-MUL
Incl. AF-BC AF-ATL
Incl. AF-BC AF-ATL PC
BoxX
EXT SPK
WAV
AF-RS232
AF-RS232
AF-ATL
AF-D232
BoxX
PC
PC
PC
Each Comat BoxX can be controlled via a telephone line if connected to the extension module AF-MUL (voice & remote unit). The AF-MUL will answer calls and allows access after the password is accepted. The Comat BoxX with the AF-MUL is able to broadcast up to 98 predefinded conditions, for example alarms, over the phone network. The designated phone number is dialled and the recorded message is played over the telephone. The message can also be broadcast over auxiliary loudspeakers.
Messages are transferred to the voice module as *.wav files directly from the PC over the AF-AUD cable.
Programming simulation and monitoring with the PC.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
SMS Relay / Comat BoxX
AF-BC
AF-AUD
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
5
143
KAT 2008
BoxX 6 INPUTS 4 OUTPUTS
UB
The Types
AC 110 -240 V
AC 110 -240 V A
50 / 60 Hz 6 /12 Inputs digital AC110 -240 V 4 / 8 Ouputs relays 8 A 250 V A
Order no.
1
2
L N N UB
6
Q2
4x
RELAY 8A 250V
Q4
without display AF-10 MR-A-CAP/AC 110-240 V with display AF-10 MR-A-LCD/AC 110-240 V
DC 24VD
DC 24VD or
INPUT 1
12 x
2
BoxX AF-20MR-A-...
BUS OUTPUT
Q1
AC 110 -240 V A
50 / 60 Hz
6x
BoxX AF-10MR-A-... RELAY 8A 250V
AC 110 -240 V
INPUT
L N N UB
12 INPUTS 8 OUTPUTS
UB
BUS OUTPUT
Q1
Q2
8x
4 / 8 Outputs relays 8 A 250 V A
Order no. 4 / 8 Transistor outputs PNP 2 A 24 V D
Order no.
++
1
2
0-10V
DC 24VD
DC 24VD or
RELAY 8A 250V
++
6
Q2
4x
RELAY 8A 250V
Q4
without display AF-10 MR-D-CAP/DC 24 V with display AF-10 MR-D-LCD / DC 24 V
PNP 2A 24VD
+ Q2
4x
PNP 2A 24VD
Q4
without display AF-10 MT-GD-CAP/DC 24 V with display AF-10 MT-GD-LCD / DC 24 V
Voice and remote unit
AF-MUL / DC12-24 V
Voice and remote unit 1)
1)
8x
OUTPUT
+
+
Q1
Q2
8x
AF-D232
Programming cable
CMS-USB
Converter USB-RS 232 Modem
AF-BC
AF-MUL Bridge connector 2)
AF-M232
Modem Interface connector
AF-ATL
AF-5MUL Audio Cable
AF-LCD
Display with function keys
AF-AUD
Audio Cable
AF-CAP
Cover (instead of AF-LCD)
AF-CDR1
CD-ROM
2)
AF-BC and AF-ATL with AF-MUL
Operating voltage UB
Switching power Ambience conditions
Q8
+ Q8
AF-20
AF- MUL
AC110 -240 V A 50 / 60 Hz
AC110 -240 V A
DC 24 V D
DC 12-24 V D
3 VA /1,5 W 8 A 250 V A Tu without display
- 25 ... + 55 °C
This edition replaces all previous issues. Availability, errors and specification subject to change without notice.
Q2
AF-MOD
Power consumption
KAT 2008
Q1
AF-MUL Programming cable
AF-10
144
OUTPUT
AF-RS232
2) Included
The Data
BUS
Order no.
AF-MUL / AC110-240 V
1) Inclusive
12
without display AF-20MT-GD-CAP/DC 24 V with display AF-20MT-GD-LCD / DC 24 V
Order no. Accessories
12 x
2
without display AF-20MR-D-CAP/DC 24 V with display AF-20MR-D-LCD / DC 24 V
OUTPUT +
+ Q1
1
BoxX AF-20MR-D-...
BUS OUTPUT
Q1
0-10V
INPUT
6x
BoxX AF-10MR-D-...
Q8
without display AF-20MR-A-CAP/AC 110-240 V with display AF-20MR-A-LCD/AC 110-240 V
INPUT 6 /12 Inputs configurable: digital / analog 0 -10 V (0,1V)
12
max.10 % 5 VA /1,5 W
0,8 VA
2 A 24 V D Tu with display Rel. humidity: 5 ... 95 % Protection 0 ... + 55 °C (non condensing) IP20
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • info@comat.ch
Comat worldwide AUSTRALIA OHMIC CONTROLS PTY LTD. www.ohmic.com.au
AUSTRIA ELTAX GMBH www.eltax.at INTERMADOX GMBH www.intermadox.at
BELARUS FEK COMPANY www.turck.by
BELGIUM MULTIPROX N.V. www.multiprox.be
GERMANY COMAT SAM STEUERUNGSTECHNIK www.comat-online.de www.releco-online.de KÜHN CONTROLS S.L. www.multicomat.de www.releco-comat.de
GREAT BRITAIN CAMIS COMPONENTS www.camiscomponents.com
GREECE VASSILIS GETSOS (MEGA EL) getsosva@acci.gr
CANADA CHARTWELL ELECTRONICS INC. www.chartwell.ca
CHINA P.R. ELCO (TIANJIN) ELECTRONICS CO. LTD www.elco-holding.com
CROATIA VARGA ELEKTRONIK D.O.O. www.varga-elektronik.hr TIPTEH D.O.O. www.tipteh.si
CZECH REPUBLIC TURCK S.R.O. www.turck.cz
DENMARK HANS FÖLSGAARD AS www.hf.net
EGYPT E.T.E. EGYPTIAN TRADING AND ENGINEERING CO. ete@internetegypt.com
TURCK HUNGARY KFT. www.turck.hu
OSAUHING «SYSTEM TEST» www.systemtest.ee
FINLAND KY VARESTE KB www.vareste.fi OEM FINLAND OY www.oem.fi
FRANCE TURCK BANNER S.A.S. www.turckbanner.fr
ROMANIA SYSCOM 18 S.R.L. www.syscom.ro TURCK BRANCH OFFICE ROMANIA www.turck.ro
SENSORLINK www.sensorlink.ru
SINGAPORE INDIA CONCORD AUTOMATION & CONTROLS www.cacindia.net
INDONESIA PT.YABESTINDO MITRA UTAMA J.L. yabestindo-pt@yahoo.com
IRELAND CAMIS COMPONENTS www.camiscomponents.com
ITALY S.P.I.I. SOCIETÀ PER AZIONI www.spii.it
MECOMB SINGAPORE LIMITED www.mecomb.com.sg
SLOVAKIA MARPEX S.R.O. www.marpex.sk
SLOVENIA TIPTEH D.O.O. www.tipteh.si
SOUTH AFRICA RET AUTOMATION www.retautomation.co.za
SPAIN KOREA SAMWHA ENGINEERING CO. LTD. Korea Seoul www.samwha.co.kr
LITHUANIA HIDROTEKA www.hidroteka.lt
MALAYSIA ELECTRICAL MARKETING SDN. BHD. www.elemar.com.my
MAROCCO ESTONIA
PORTUGAL SALMON & CIA. LDA. www.salmon.pt
RUSSIA HUNGARY
BULGARIA SENSOMAT GMBH www.sensomat.info
POLAND ANIM EXPORT www.anim.com.pl
CENELEC S.A. cenelec@cenelec.co.ma
NETHERLANDS VIERPOOL B.V. www.vierpool.nl
NORWAY DANYKO A.S. www.danyko.no
PHILIPPINES MANUEL H.M. MANUEL ENTERPRISES www.hmmanuel.com.ph
RELECO S.A. www.releco.com
SWEDEN BEVING ELEKTRONIK AB www.bevingelektronik.se
TAIWAN E-SENSORS & AUTOMATION INT’L CORP. www.e-sensors.com.tw
THAILAND SRINUTCH COMPONENTS CO. LTD. www.srinutch.com
TURKEY CERAN AUTOMATION www.ceran.com.tr
UKRAINE SENSORLINK www.sensorlink.ru
USA WOERTZ-USA www.woertz-usa.com
cw/ 4.08
GK08/ 6.08e EX
COMAT AG • BERNSTR. 4 CH-3076 WORB TEL. +41 (0)31 838 55 77 FAX +41 (0)31 838 55 99 www.comat.ch • info@comat.ch