EB RELAYS (AEB)
HIGH CAPACITY CUT-OFF RELAY FOR 42V VEHICLES 70 2.756
80 3.150 34 1.339
100A type * 30A type is also under development.
FEATURES
TYPICAL APPLICATIONS
• Compact and high capacity using double contacts in series and permanent magnet installed. (1,000A/3 times) cut-off possible (EB Relay 100A type) • Compact and lightweight for space savings and improved gas mileage.
Equipment requiring high capacity shutoff such as main power supplies for 42 V vehicles, motor assisters, quick recharging power supplies for AGVs (automatic guided vehicle), and motor controls for forklifts, etc.
SPECIFICATIONS Contact
Characteristics
Type Arrangement Between terminal voltage drop (Initial) Material
Rating
Nominal switching capacity (resistive load) Max. carrying current Min. switching capacity #2 Max. cut-off current
Overload opening/ closing rating Mechanical Expected life (min. operations) Electrical*2
30A (Under 100A development#1) 1 Form A Max. 0.15V Max. 0.15V (By voltage drop (By voltage drop 42V DC 100A) 42V DC 10A) Silver alloy 100A 42V DC
30A 42V DC
1,000A (0.1s)
80A (1.0s)
1A 12V DC 1,000A 48V DC/ 3 cycle*1 400A 55V DC/ 10 cycle
80A 55V DC/ 10 cycle —
10 104 105 (at 100A 42V DC) (at 30A 42V DC) 6
Notes: #1 The 30A type is under development; therefore, specifications are subject to change without notice. #2 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. #3 When using a surge absorbing element for the relay coil drive circuit, please use with a surge absorbing element with a clamp voltage of 18V/54V or more. When the coil is connected in parallel with a diode, resistor or capacitor, the revert time will delay which might lead to degradation in shutoff performance and electrical working life. Contact terminals have polarity; therefore, please obey the wiring diagram when connecting contacts. The electrical load performance value applies when a varistor is connected in parallel with the coil.
Type Initial insulation resistance*3 (Initial) (at 500 V DC) Between open Initial breakdown contacts voltage Between contact and (Initial) coil Operate time (at 20°C) (at nominal voltage) Release time (at 20°C) (at nominal voltage) Functional Shock resistance*5 Destructive*6 Functional Vibration resistance*7 Destructive*8 Conditions for operation, transport and storage*9 Ambient (Not freezing and temperature condensing at low temperature) Mass
100A
30A (Under development#1)
Min. 100MΩ
Min. 20MΩ
AC 1,500 Vrms for min. AC 2,500 Vrms for 1 min.
AC 500 Vrms for min. AC 500 Vrms for 1 min.
Max. 30ms*4
Max. 12ms*4
Max. 15ms
Max. 5ms
Min. 196 m/s2 {20.4G} Min. 980 m/s2 {100G} 44.1 m/s2 {4.5G} 10 to 500Hz 44.1 m/s2 {4.5G} 10 to 200 Hz –40°C to +80°C –40°F to +176°F 300g 10.58oz
35g 1.23oz
Remarks *1 Condition: Condition: Nominal switching 100cycles, each cut off 1,000A *2 Resistive load, operating frequency 1s ON, 9s OFF, room temperature *3 Measurement at same location as “Initial breakdown voltage” section. *4 Nominal voltage applied to the coil,excluding bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10µs, 12V DC applied to the coil. *6 Half-wave pulse of sine wave: 6 ms, 12V DC applied to the coil or deenergized. 7 * 12V DC applied to the coil *8 12V DC applied to the coil or deenergized. *9 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
TYPES Contact arrangement 1 Form A
Coil voltage, V DC 12 36
Protective costruction
Terminal shape
Dust cover
Screw terminal
Part No. AEB310012 AEB310036
COIL DATA Type 100A 30A (Under development#)
Coil voltage, V DC 12 36 12 36
Pick-up voltage, V DC (Initial) (at 20°C) Max. 9.0 Max. 27.0 Max. 9.0 Max. 27.0
Drop-out voltage, V DC (Initial) (at 20°C) Min. 1.0 Min. 3.0 Min. 1.0 Min. 3.0
Nominal operating current, mA (at 20°C) 410±10% 139±10% 150±10% 50±10%
Coil resistance, Ω (at 20°C) 29.0±10% 260±10% 80±10% 720±10%
Nominal operating power, W (at 20°C) 5.0 5.0 1.8 1.8
Note: # The 30 A type is under development; therefore, specifications are subject to change without notice.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Max. allowable voltage, V DC 9 to 16 27 to 48 9 to 16 27 to 48