Panasonic HY Relays

Page 1

HY NON-POLARIZED 1 FORM C RELAY

FEATURES

7.4 .291

12 .472

HY RELAYS

• High sensitivity: 150 mW/200 mW • A wide range of ambient temperature: –40°C to +70°C –40°F to +158°F • Sealed construction • Rating: 1 A 30 V DC

10.1 .398

mm inch

SPECIFICATIONS Contact

Characteristics (at 25°C 77°F, 50% Relative humidity)

Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Max. switching power Rating Max. switching voltage (resistive) Max. switching current Max. carrying current Mechanical (at 180 cpm) Expected life Electrical (at 20 cpm) (min. operations) 1 A 30 V DC

1 Form C

Max. operating speed Between contacts Initial insulation Between contact and resistance*1 coil

100 mΩ Gold-clad silver 1 A 30 V DC 30 W 60 V DC 1A 2A 107

Between open contacts Between contacts and coil Operate time*3 (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Temperature rise at nominal voltage Contact carrying current 1 A at 20°C Functional*4 Shock resistance Destructive*5

Initial breakdown voltage*2

105

Coil Nominal operating power

Standard type High sensitivity type

200 mW 150 mW

1,000 Vrms Max. 5 ms (approx. 2 ms) Max. 4 ms (approx. 1 ms) Max. 50°C

Humidity

5 to 85% R.H.

Destructive Conditions for operation, transport and storage*7 (Not freezing and condensing at low temperature) Unit weight

500 Vrms

Ambient temp.

Vibration resistance

* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT

Min. 100 MΩ at 500 V DC

Min. 98 m/s2 (10 G) Min. 980 m/s2 (100 G) 58.8 m/s2 {6 G}, 10 to 55 Hz at double amplitude of 1 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2 mm –40°C to +70°C –40°F to +158°F

Functional*6

Remarks

20 cpm (at nominal voltage) Min. 100 MΩ at 500 V DC

1.8 g .063 oz

TYPICAL APPLICATIONS • Low-voltage signal switching and motor control of small home appliances such as portable video tape recorders and audio devices.

• Automotive: Switching to small motor 1) Automirrow controller 2)Retractable head light controller • Push button device: Dial pulsing

• Operating of dish-control motors for PCs and word processors

ORDERING INFORMATION Ex. HY

1

Z

3V

Contact arrangement

Sensitivity

Coil voltage (DC)

1: 1 Form C

Nil: High sensitivity 150 mW Z: Standard 200 mW

1.5, 3, 4.5, 5, 6, 9, 12, 24 V

Standard packing: Tube: 50 pcs.; Case: 2,000 pcs. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


HY TYPES AND COIL DATA (at 20°C 68°F) 200 mW Standard type Part No.

Nominal voltage, V DC

Pick-up voltage, V DC (max.)

HY1Z-1.5V HY1Z-3V HY1Z-4.5V HY1Z-5V HY1Z-6V HY1Z-9V HY1Z-12V HY1Z-24V

1.5 3 4.5 5 6 9 12 24

1.125 2.25 3.375 3.75 4.5 6.75 9 18

Drop-out voltage, V DC (min.) 0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4

Coil resistance, Ω (±10%) 11.25 45 101.2 125 180 405 720 2,880

Nominal operating current, mA 133.3 66.7 44.5 40 33.3 22.2 16.7 8.3

Nominal operating power, mW 200 200 200 200 200 200 200 200

Max. allowable voltage, V DC (at 70°C 158°F) 1.8 3.6 5.4 6 7.2 10.8 14.4 28.8

Nominal operating current, mA 100 50 33.3 30.1 25 16.7 12.5 6.25

Nominal operating power, mW 150 150 150 150 150 150 150 150

Max. allowable voltage, V DC (at 70°C 158°F) 2.1 4.2 6.3 7 8.4 12.6 16.8 33.6

150 mW High sensitivity type Part No.

Nominal voltage, V DC

Pick-up voltage, V DC (max.)

1.5 3 4.5 5 6 9 12 24

1.125 2.25 3.375 3.75 4.5 6.75 9 18

HY1-1.5V HY1-3V HY1-4.5V HY1-5V HY1-6V HY1-9V HY1-12V HY1-24V

Drop-out voltage, V DC (min.) 0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4

Coil resistance, Ω (±10%) 15 60 135 166 240 540 960 3,840

DIMENSIONS

mm inch PC board pattern (Copper-side view) 2.54 .100

7.62 .300

(0.82) (.032)

12 .462

7.4 .291

10.1 .398

6-1 dia. 6-.039 dia.

5.08 .200

0.5 .020

2.54 .100

3.5 .138 0.5 .020

5.08 .200

0.25 .010

2.54 .100

0.4 dia. .016 dia. 2.54 .100

0.25 .010

7.62 .300

Schematic (Bottom view) N.C.

(0.82) (.032)

COM

N.O.

General tolerance: ±0.3 ±.012

Tolerance: ±0.1 ±.004

REFERENCE DATA 1. Maximum switching power

2. Life curve

3. Mechanical life

5.0

2.0

300 200

30 V DC resistive load

100 Life, ×104

Contact current, A

DC resistive AC resistive

1.0

50 30 20 10

0.5

100 V AC resistive load

0.2

Ratio against the rated voltage, %V

Tested sample: HY1Z-12V, 10 pcs. Ambient temperature: 20°C to 25°C 68°F to 77°F 100 90 80 70 Pick-up voltage

60

Max.

50

Min.

40 Drop-out voltage

30

Max.

20 Min.

10 0.1 10

30

60 100 300 Contact voltage, V

0.2

0.4

0.6 0.8 1.0 1.2 1.4 Switching current, A

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

0

10

100 1,000 2,000 No. of operations, ×104


HY 4. Electrical life Change of pick-up and drop-out voltage

N.C. side: 3 pcs. N.O. side: 3 pcs.

90 Pick-up voltage

80 70

Max.

60 Min.

50 40

Drop-out voltage

30

Max.

20

Min.

10 4 No. of operations, ×10

5-(1). Coil temperature rise (150 mW high sensitivity type)

5-(2). Coil temperature rise (200 mW Standard type)

Tested sample: HY1-9V, 5 pcs. Ambient temperature:24°C 75°F

Tested sample: HY1Z-12V, 5 pcs. Ambient temperature: 23°C 74°F

90

1A

60 50

0A

40 30

Coil temperature rise, °C

100

90

Coil temperature rise, °C

100

70

Min. 20

0A

40 30

0

120 140 160 180 Coil applied voltage, %V

10 20 No. of operations, × 104

Tested sample: HY1Z-12V, 5 pcs. Ambient temperature: 25°C 77°F

1A

50

10

0

6. Operate/release time characteristics

60

20

100

40

20

70

10 80

Max.

3

80

20

0

60

10 0

80

80

80

100

120 140 160 180 Coil applied voltage, %V

Operate/release time, ms

Circuit:

Change of contact resistance

100 Contact resistance, mΩ

Ratio against the rated voltage, %V

Tested sample: HY1-12V, 6 pcs. Condition: 1 A 30 V DC resistive load, 30 cpm

Operate time 2

1

Release time

0

80

100 120 Coil applied voltage, %V

7. Distribution of pick-up and drop-out voltages

8. Distribution of contact resistance

9. Malfunction shock

Tested sample: HY1-12V, 50 pcs. Ambient temperature: 23°C 74°F

Tested sample: HY1-12V, 50 pcs. N.C. side N.O. side

Tested sample: HY1Z-12V, 6 pcs.

30

30 Drop-out voltage

20 Pick-up voltage 15

20

Y Z X X’ Z’ 980m/s 2 Y Y’ 980m/s 2 X

10

5

5

0

0

980m/s 2 Z’

Z 980m/s 2

980m/s 2 X’

980m/s 2 Y’ 30

40 Contact resistance mΩ

NOTE Soldering and cleaning HY relays have the sealed construction. It is possible to do automatic soldering and automatic cleaning, but avoid the ultrasonic cleaning.

Deenergized condition Energized condition

15

10

10 20 30 40 50 60 70 80 90 100 Pick-up/drop-out voltage, V

N.C. side N.O. side

25

Quantity

Quantity

25

Max. x Min. Max. x Min.

For cleaning, it is recommended that a fluorinated hydrocarbon or other alcoholic solvent be used.

For Cautions for Use, see Relay Technical Information

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.