Panasonic JV Relays

Page 1

FLAT TYPE POWER RELAY

22 .866

JV RELAYS

FEATURES

16 .630

• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height) (.630×.866×.429 inch) • High capacity type (16A) available • High sensitivity type (100 mW: 1 Form A) available • TÜV also approved

10.9 .429

mm inch

SPECIFICATIONS Contact

Standard type

Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive)

1 Form A

1 Form C

Characteristics

High capacity High type sensitivity type 1 Form A 1 Form A

Max. operating speed Initial insulation resistance*1 Between open Initial contacts breakdown Between convoltage*2 tacts and coil

50 mΩ

Max. switching power Max. switching voltage Max. switching current

Silver alloy 10 A 125 V AC (N.O.) 10 A 125 V AC 16 A 125 V AC 10 A 125 V AC 6 A 125 V AC (N.C.) 1,250 VA (N.O.) 1,250 VA 2,000 VA 1,250 V 750 VA (N.C.) 125 V AC 10 A (N.O.) 10 A 16 A 10 A 6 A (N.C.)

Expected life (min. ope.) Mechanical at (180 cpm) Electrical at resistive Sealed type (at 20 cpm) Flux-resistant (at rated load) type

Operate time*3 (at nominal voltage) Release time (without diode)* 3 (at nominal voltage)

107

Coil

105

105

3×104

5×104

3×105

105

105

105

1 Form A type

200 mW (up to 48 V coil type) Nominal Standard type 600 mW (100 V coil type) operating High capacity type power High sensitivity type 100 mW

20 cpm Min. 100 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 10 ms Approx. 5 ms (100 V DC coil type) Approx. 4 ms Max. 65°C with nominal coil voltage across coil and at nominal switching capacity

Temperature rise (at 50°C) Functional*4 Shock resistance Destructive*5

Min. 98 m/s2 {10 G} Min. 980 m/s2 {100 G} 10 to 55 Hz Functional*6 at double amplitude of 1.0 mm Vibration resistance 10 to 55 Hz Destructive at double amplitude of 1.6 mm Conditions for opera- Ambient –40°C to +70°C*8 tion, transport and temp. –40°F to +158°F storage*7 (Not freezing and Humidity 5 to 85%R.H. condensing at low temperature) Unit weight Approx. 8 g .282 oz

1 Form C type 400 mW (up to 48 V coil type) 600 mW (100 V coil type) — —

Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage"section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms, detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT . *8 100V type: –40 to + 60°C –40 to + 140°F

TYPICAL APPLICATIONS 1. Home appliances: Air conditioner, heater, etc. 2. Automotive: Power supply for car stereo and air conditioner

ORDERING INFORMATION Ex. JV

1a

P

F

Contact arrangement

Rating

Protective construction

1: 1 Form C 1a: 1 Form A

Nil: Standard type P: High capacity type*

Nil: Sealed type F: Flux-resistant type

S

12V

Sensitivity Nil: Standard type (1 Form A: 200 mW, 1Form C: 400 mW 100 V DC coil type: 600 mW) S: High sensitivity type* (1 Form A: 100 mW)

Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs. 2. Coil voltage DC 48, 100 V types are not available for high sensitivity type. UL/CSA, TÜV approved type is standard. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48, 100V

* Only for 1 Form A type


JV TYPES Contact arrangement

Coil voltage, V DC

1 Form A Standard type

1 Form A High capacity type

1 Form A High sensitivity type

1 Form C

5 6 9 12 18 24 48 100 5 6 9 12 18 24 48 100 5 6 9

Sealed type JV1a-5V JV1a-6V JV1a-9V JV1a-12V JV1a-18V JV1a-24V JV1a-48V JV1a-100V JV1aP-5V JV1aP-6V JV1aP-9V JV1aP-12V JV1aP-18V JV1aP-24V JV1aP-48V JV1aP-100V JV1aS-5V JV1aS-6V JV1aS-9V

12 18 24 5 6 9 12 18 24 48 100

JV1aS-12V JV1aS-18V JV1aS-24V JV1-5V JV1-6V JV1-9V JV1-12V JV1-18V JV1-24V JV1-48V JV1-100V

Part No. Flux-resistant type JV1aF-5V JV1aF-6V JV1aF-9V JV1aF-12V JV1aF-18V JV1aF-24V JV1aF-48V JV1aF-100V JV1aPF-5V JV1aPF-6V JV1aPF-9V JV1aPF-12V JV1aPF-18V JV1aPF-24V JV1aPF-48V JV1aPF-100V JV1aFS-5V JV1aFS-6V JV1aFS-9V JV1aFS-12V JV1aFS-18V JV1aFS-24V JV1F-5V JV1F-6V JV1F-9V JV1F-12V JV1F-18V JV1F-24V JV1F-48V JV1F-100V

COIL DATA (at 20°C 68°F) Part No.

1 Form A (Standard type & High capacity type)

1 Form A (High sensitivity type)

1 Form C

Nominal voltage, V DC

Pick-up voltage, V DC (max.)

5 6 9 12 18 24 48 100 5 6 9 12 18 24 5 6 9 12 18 24 48 100

4.0 4.8 7.2 9.6 14.4 19.2 38.4 48 4.0 4.8 7.2 9.6 14.4 19.2 4.0 4.8 7.2 9.6 14.4 19.2 38.4 70

Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 2.4 3 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 5

Coil resistance, Ω (±10%) 125 180 405 720 1,620 2,880 11,520 16,600 250 360 810 1,440 3,240 5,760 62.5 90 202.5 360 810 1,440 5,760 16,600

Nominal operating current, mA (±10%) 40 33.3 22.2 16.7 11.1 8.3 4.2 6 20 16.7 11.1 8.3 5.6 4.2 80 66.7 44.4 33.3 22.2 16.7 8.3 6

Nominal operating power, mW 200 200 200 200 200 200 200 600 100 100 100 100 100 100 400 400 400 400 400 400 400 600

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Max. allowable voltage, V DC 7.5 9 13.5 18 27 36 72 110 9 10.8 16.2 21.6 32.4 43.2 6.5 7.8 11.7 15.6 23.4 31.2 62.4 110


JV DIMENSIONS

mm inch

1 Form A type

1 Form C type

22 .866

16 .630

22 .866

16 .630

10.5 0.4 .413 .016

10.5 0.4 .413 .016

4 .157

4 .157

PC board pattern (Copper-side view)

17.78 .700 2

17.78 .700

1

PC board pattern (Copper-side view)

17.78 .700

2-0.9 dia. 2-.035 dia.

2

12.7 .500 COM 3

NO

2-0.9 dia. 2-.035 dia.

12.7 .500

NC 5

4

17.78 .700

1

COM 3

12.7 .500

10.16 .400

2-1.3 dia. 2-.051 dia.

Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch

General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016

NO

NC 5

4

10.16 .400 10.16 .400

12.7 .500

7.62 .300

3-1.3 dia. 3-.051 dia.

Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch

Tolerance: ±0.1 ±.004

10.16 .400

General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016

7.62 .300

Tolerance: ±0.1 ±.004

REFERENCE DATA 1.-(1) Maximum value for switching capacity (1 Form A type)

1.-(2) Maximum value for switching capacity (1 Form C type) 100

Contact current, A

High capacity type, AC resistive load 16 10 Standard type, AC resistive load

AC resistive load (NO side)

10

1

1

18

Operate/release time, ms

100

Contact current, A

2.-(1) Operate/release time (Standard 1 Form A type)

16 14 12

Operate time

10 8 6 4

Max. – x Min. Max. – x Min.

Release time

2 100

10

1,000

100

16 14 12 10 Operate time

6 Release time

2 0

80

100 120

80

100

120

140

160

180

3.-(1) Coil temperature rise (1 Form A type) Measured portion: Inside the coil

18

4

0

Coil applied voltage, %V

2.-(3) Operate/release time (1 Form C type)

Operate/release time, ms

Operate/release time, ms

2.-(2) Operate/release time (High capacity 1 Form A type)

8

1,000

Contact voltage, V

Contact voltage, V

140 160

Max. – x Min. Max. – x Min. 180

10 8 Operate time 6

Release time 2

0

80

100

80

120

140

60

10 A at 60°C 140°F (Standad type)

40

20

0

160

80

100

Coil applied voltage, %V

3.-(2) Coil temperature rise (1 Form C type)

3.-(3) Coil temperature rise (High sensitivity type)

Measured portion: Inside the coil

Measured portion: Inside the coil

10 A at 15°C 59°F (Standad type)

15 A at 60°C 140°F (High capacity type)

Max. – x Min. Max. – x Min.

4

Coil applied voltage, %V

15 A at 26°C 79°F (High capacity type)

Temperature rise, °C

10

120

140 160

180

Coil applied voltage, %V

4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s:1.5s) Ambient temperature: Room temperature 100

60

10 A at 25°C 77°F 60

40

125V AC resistive load 40

Life, ×104

80

Temperature rise, °C

Temperature rise, °C

Standard 200 mW type

10

High sensitivity 100 mW type 20

20

0

80

100

120

140 160

180

Coil applied voltage, %V

0

0 100

120

140

160

180

200

Coil applied voltage, %V

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

1

4

6

8

10

12

14

Contact current, A

16

18


JV Contact current: 10 A

Contact current: 0 A, 10 A, 13 A, 15 A

Contact current: 10 A

Allowable ambient temperatures against % coil voltage (max. inside the coil temperature set as 115°C 239°F)

300

200

Pick-up voltage with a hot-start condition of 100%V on the coil

0 300

200

100

100 Pick-up voltage

0

20

40

60

80

100

0

120

Coil applied voltage, %V

5.-(3) Ambient temperature characteristics (1 Form C type)

Coil applied voltage, %V

5.-(2) Ambient temperature characteristics (High capacity 15 A type, 1 Form A)

Coil applied voltage, %V

5.-(1) Ambient temperature characteristics (Standard 10 A type, 1 Form A)

A

10

A 13 A 15 A

Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 13 A 15 A 115°C 239°F) Pick-up voltage with a hot-start condition of 100%V on the coil 10 A Pick-up voltage 0A 20 40 60 80 100 120

Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F)

200

Pick-up voltage 100

0

20

Ambient temperature, °C

Ambient temperature, °C

40

60

80

Ambient temperature, °C

5.-(4) Ambient temperature characteristics (High sensitivity type) Contact current: 10 A

Coil applied voltage, %V

300 High sensitivity 100 mW type

Standard 200 mW type

200

Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 115°C 239°F)

100

0

0

20

40

60

80

100

120

Temperature rise, °C

Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications:

SPECIFICATIONS Contact

Characteristics

Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive Max. switching power load) Max. switching voltage Max. switching current Mechanical (at 300 cpm) Expected Electrical life (min. (DC 12 V motor, 6 A steady current, ope.) 20 A lock current)(at rated load)

1 Form C 100 mΩ Silver alloy 10 A 125 V AC 6A 30 V DC 1,250 V AC 180 W 125 V (AC) 30 V (DC) 10 A (AC) 6 A (DC) 5×106

Functional 4×104

Vibration resistance Destructive

Coil Nominal voltage, V DC Nominal operating power Pick-up voltage, V DC (max.) Drop-out voltage; V DC (min.) Max. allowable voltage

Max. operating speed Initial insulation resistance Initial break Between open contacts down voltage Between contacts and coil Operate time (at nominal voltage) Release time (at nominal voltage) Temperature rise (max.) (at nominal voltage)(at 50°C) Functional Shock resistance Destructive

5, 6, 9, 12, 18, 24 450 mW 70% of nominal voltage 5% of nominal voltage 150% of nominal voltage

Conditions for operation, Ambient temp. transport and storage (Not freezing and condensHumidity ing at low temperature)

20 cpm Min. 100 MΩ (at 500 V DC) 750 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 5 ms Approx. 4 ms 65°C with nominal coil voltage and at maximum allowable contact current Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1.6 mm 10 to 55 Hz at double amplitude of 2 mm –40°C to +70°C –40°F to +158°F

Unit weight

For Cautions for Use, see Relay Technical Information.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

5 to 85%R.H. Approx. 8 g .282 oz