FLAT TYPE POWER RELAY
22 .866
JV RELAYS
FEATURES
16 .630
• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height) (.630×.866×.429 inch) • High capacity type (16A) available • High sensitivity type (100 mW: 1 Form A) available • TÜV also approved
10.9 .429
mm inch
SPECIFICATIONS Contact
Standard type
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive)
1 Form A
1 Form C
Characteristics
High capacity High type sensitivity type 1 Form A 1 Form A
Max. operating speed Initial insulation resistance*1 Between open Initial contacts breakdown Between convoltage*2 tacts and coil
50 mΩ
Max. switching power Max. switching voltage Max. switching current
Silver alloy 10 A 125 V AC (N.O.) 10 A 125 V AC 16 A 125 V AC 10 A 125 V AC 6 A 125 V AC (N.C.) 1,250 VA (N.O.) 1,250 VA 2,000 VA 1,250 V 750 VA (N.C.) 125 V AC 10 A (N.O.) 10 A 16 A 10 A 6 A (N.C.)
Expected life (min. ope.) Mechanical at (180 cpm) Electrical at resistive Sealed type (at 20 cpm) Flux-resistant (at rated load) type
Operate time*3 (at nominal voltage) Release time (without diode)* 3 (at nominal voltage)
107
Coil
105
105
3×104
5×104
3×105
105
105
105
1 Form A type
200 mW (up to 48 V coil type) Nominal Standard type 600 mW (100 V coil type) operating High capacity type power High sensitivity type 100 mW
20 cpm Min. 100 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 10 ms Approx. 5 ms (100 V DC coil type) Approx. 4 ms Max. 65°C with nominal coil voltage across coil and at nominal switching capacity
Temperature rise (at 50°C) Functional*4 Shock resistance Destructive*5
Min. 98 m/s2 {10 G} Min. 980 m/s2 {100 G} 10 to 55 Hz Functional*6 at double amplitude of 1.0 mm Vibration resistance 10 to 55 Hz Destructive at double amplitude of 1.6 mm Conditions for opera- Ambient –40°C to +70°C*8 tion, transport and temp. –40°F to +158°F storage*7 (Not freezing and Humidity 5 to 85%R.H. condensing at low temperature) Unit weight Approx. 8 g .282 oz
1 Form C type 400 mW (up to 48 V coil type) 600 mW (100 V coil type) — —
Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage"section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms, detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT . *8 100V type: –40 to + 60°C –40 to + 140°F
TYPICAL APPLICATIONS 1. Home appliances: Air conditioner, heater, etc. 2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION Ex. JV
1a
P
F
Contact arrangement
Rating
Protective construction
1: 1 Form C 1a: 1 Form A
Nil: Standard type P: High capacity type*
Nil: Sealed type F: Flux-resistant type
S
12V
Sensitivity Nil: Standard type (1 Form A: 200 mW, 1Form C: 400 mW 100 V DC coil type: 600 mW) S: High sensitivity type* (1 Form A: 100 mW)
Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs. 2. Coil voltage DC 48, 100 V types are not available for high sensitivity type. UL/CSA, TÜV approved type is standard. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48, 100V
* Only for 1 Form A type
JV TYPES Contact arrangement
Coil voltage, V DC
1 Form A Standard type
1 Form A High capacity type
1 Form A High sensitivity type
1 Form C
5 6 9 12 18 24 48 100 5 6 9 12 18 24 48 100 5 6 9
Sealed type JV1a-5V JV1a-6V JV1a-9V JV1a-12V JV1a-18V JV1a-24V JV1a-48V JV1a-100V JV1aP-5V JV1aP-6V JV1aP-9V JV1aP-12V JV1aP-18V JV1aP-24V JV1aP-48V JV1aP-100V JV1aS-5V JV1aS-6V JV1aS-9V
12 18 24 5 6 9 12 18 24 48 100
JV1aS-12V JV1aS-18V JV1aS-24V JV1-5V JV1-6V JV1-9V JV1-12V JV1-18V JV1-24V JV1-48V JV1-100V
Part No. Flux-resistant type JV1aF-5V JV1aF-6V JV1aF-9V JV1aF-12V JV1aF-18V JV1aF-24V JV1aF-48V JV1aF-100V JV1aPF-5V JV1aPF-6V JV1aPF-9V JV1aPF-12V JV1aPF-18V JV1aPF-24V JV1aPF-48V JV1aPF-100V JV1aFS-5V JV1aFS-6V JV1aFS-9V JV1aFS-12V JV1aFS-18V JV1aFS-24V JV1F-5V JV1F-6V JV1F-9V JV1F-12V JV1F-18V JV1F-24V JV1F-48V JV1F-100V
COIL DATA (at 20°C 68°F) Part No.
1 Form A (Standard type & High capacity type)
1 Form A (High sensitivity type)
1 Form C
Nominal voltage, V DC
Pick-up voltage, V DC (max.)
5 6 9 12 18 24 48 100 5 6 9 12 18 24 5 6 9 12 18 24 48 100
4.0 4.8 7.2 9.6 14.4 19.2 38.4 48 4.0 4.8 7.2 9.6 14.4 19.2 4.0 4.8 7.2 9.6 14.4 19.2 38.4 70
Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 2.4 3 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 5
Coil resistance, Ω (±10%) 125 180 405 720 1,620 2,880 11,520 16,600 250 360 810 1,440 3,240 5,760 62.5 90 202.5 360 810 1,440 5,760 16,600
Nominal operating current, mA (±10%) 40 33.3 22.2 16.7 11.1 8.3 4.2 6 20 16.7 11.1 8.3 5.6 4.2 80 66.7 44.4 33.3 22.2 16.7 8.3 6
Nominal operating power, mW 200 200 200 200 200 200 200 600 100 100 100 100 100 100 400 400 400 400 400 400 400 600
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Max. allowable voltage, V DC 7.5 9 13.5 18 27 36 72 110 9 10.8 16.2 21.6 32.4 43.2 6.5 7.8 11.7 15.6 23.4 31.2 62.4 110
JV DIMENSIONS
mm inch
1 Form A type
1 Form C type
22 .866
16 .630
22 .866
16 .630
10.5 0.4 .413 .016
10.5 0.4 .413 .016
4 .157
4 .157
PC board pattern (Copper-side view)
17.78 .700 2
17.78 .700
1
PC board pattern (Copper-side view)
17.78 .700
2-0.9 dia. 2-.035 dia.
2
12.7 .500 COM 3
NO
2-0.9 dia. 2-.035 dia.
12.7 .500
NC 5
4
17.78 .700
1
COM 3
12.7 .500
10.16 .400
2-1.3 dia. 2-.051 dia.
Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch
General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016
NO
NC 5
4
10.16 .400 10.16 .400
12.7 .500
7.62 .300
3-1.3 dia. 3-.051 dia.
Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch
Tolerance: ±0.1 ±.004
10.16 .400
General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016
7.62 .300
Tolerance: ±0.1 ±.004
REFERENCE DATA 1.-(1) Maximum value for switching capacity (1 Form A type)
1.-(2) Maximum value for switching capacity (1 Form C type) 100
Contact current, A
High capacity type, AC resistive load 16 10 Standard type, AC resistive load
AC resistive load (NO side)
10
1
1
18
Operate/release time, ms
100
Contact current, A
2.-(1) Operate/release time (Standard 1 Form A type)
16 14 12
Operate time
10 8 6 4
Max. – x Min. Max. – x Min.
Release time
2 100
10
1,000
100
16 14 12 10 Operate time
6 Release time
2 0
80
100 120
80
100
120
140
160
180
3.-(1) Coil temperature rise (1 Form A type) Measured portion: Inside the coil
18
4
0
Coil applied voltage, %V
2.-(3) Operate/release time (1 Form C type)
Operate/release time, ms
Operate/release time, ms
2.-(2) Operate/release time (High capacity 1 Form A type)
8
1,000
Contact voltage, V
Contact voltage, V
140 160
Max. – x Min. Max. – x Min. 180
10 8 Operate time 6
Release time 2
0
80
100
80
120
140
60
10 A at 60°C 140°F (Standad type)
40
20
0
160
80
100
Coil applied voltage, %V
3.-(2) Coil temperature rise (1 Form C type)
3.-(3) Coil temperature rise (High sensitivity type)
Measured portion: Inside the coil
Measured portion: Inside the coil
10 A at 15°C 59°F (Standad type)
15 A at 60°C 140°F (High capacity type)
Max. – x Min. Max. – x Min.
4
Coil applied voltage, %V
15 A at 26°C 79°F (High capacity type)
Temperature rise, °C
10
120
140 160
180
Coil applied voltage, %V
4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s:1.5s) Ambient temperature: Room temperature 100
60
10 A at 25°C 77°F 60
40
125V AC resistive load 40
Life, ×104
80
Temperature rise, °C
Temperature rise, °C
Standard 200 mW type
10
High sensitivity 100 mW type 20
20
0
80
100
120
140 160
180
Coil applied voltage, %V
0
0 100
120
140
160
180
200
Coil applied voltage, %V
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
1
4
6
8
10
12
14
Contact current, A
16
18
JV Contact current: 10 A
Contact current: 0 A, 10 A, 13 A, 15 A
Contact current: 10 A
Allowable ambient temperatures against % coil voltage (max. inside the coil temperature set as 115°C 239°F)
300
200
Pick-up voltage with a hot-start condition of 100%V on the coil
0 300
200
100
100 Pick-up voltage
0
20
40
60
80
100
0
120
Coil applied voltage, %V
5.-(3) Ambient temperature characteristics (1 Form C type)
Coil applied voltage, %V
5.-(2) Ambient temperature characteristics (High capacity 15 A type, 1 Form A)
Coil applied voltage, %V
5.-(1) Ambient temperature characteristics (Standard 10 A type, 1 Form A)
A
10
A 13 A 15 A
Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 13 A 15 A 115°C 239°F) Pick-up voltage with a hot-start condition of 100%V on the coil 10 A Pick-up voltage 0A 20 40 60 80 100 120
Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F)
200
Pick-up voltage 100
0
20
Ambient temperature, °C
Ambient temperature, °C
40
60
80
Ambient temperature, °C
5.-(4) Ambient temperature characteristics (High sensitivity type) Contact current: 10 A
Coil applied voltage, %V
300 High sensitivity 100 mW type
Standard 200 mW type
200
Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 115°C 239°F)
100
0
0
20
40
60
80
100
120
Temperature rise, °C
Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications:
SPECIFICATIONS Contact
Characteristics
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive Max. switching power load) Max. switching voltage Max. switching current Mechanical (at 300 cpm) Expected Electrical life (min. (DC 12 V motor, 6 A steady current, ope.) 20 A lock current)(at rated load)
1 Form C 100 mΩ Silver alloy 10 A 125 V AC 6A 30 V DC 1,250 V AC 180 W 125 V (AC) 30 V (DC) 10 A (AC) 6 A (DC) 5×106
Functional 4×104
Vibration resistance Destructive
Coil Nominal voltage, V DC Nominal operating power Pick-up voltage, V DC (max.) Drop-out voltage; V DC (min.) Max. allowable voltage
Max. operating speed Initial insulation resistance Initial break Between open contacts down voltage Between contacts and coil Operate time (at nominal voltage) Release time (at nominal voltage) Temperature rise (max.) (at nominal voltage)(at 50°C) Functional Shock resistance Destructive
5, 6, 9, 12, 18, 24 450 mW 70% of nominal voltage 5% of nominal voltage 150% of nominal voltage
Conditions for operation, Ambient temp. transport and storage (Not freezing and condensHumidity ing at low temperature)
20 cpm Min. 100 MΩ (at 500 V DC) 750 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 5 ms Approx. 4 ms 65°C with nominal coil voltage and at maximum allowable contact current Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1.6 mm 10 to 55 Hz at double amplitude of 2 mm –40°C to +70°C –40°F to +158°F
Unit weight
For Cautions for Use, see Relay Technical Information.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
5 to 85%R.H. Approx. 8 g .282 oz