Panasonic HJ Relays

Page 1

HJ

TÜV Rheinland

MINIATURE RELAY FOR WIDER APPLICATIONS

HJ RELAYS

FEATURES

TYPICAL APPLICATIONS

• 2 contact arrangements 4 Form C (for 5 A 250 V AC), 2 Form C (for 7 A 250 V AC) • Excellent contact reliability by Au plating • Environmentally friendly Cd-free contacts • Coil breakdown detection function (AC type with LED only) • Convenient Screw terminal sockets with finger protection also available • Test button type available • Built-in diode and CR for surge suppression type available

Control panels Power supply units Molding machines Machine tools Welding equipment Agricultural equipment Office equipment Vending machines Communications equipment Amusement machines

ORDERING INFORMATION Ex. HJ

Contact arrangement 2: 2 Form C 4: 4 Form C

Operation indication

Test button

Coil voltage

Surge suppression

Contact surface

Nil: Without D: With diode R: With CR

Nil: Without 6: With Au plating

Nil: Without LED indication Nil: Without test button AC 12, 24, 48, 100/110, 110/ L: With LED indication T: With test button 120, 200/220, 220/240 V DC 12, 24, 48, 100/110 V

SPECIFICATIONS Contacts Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material

Characteristics 2 Form C

4 Form C 50mΩ

Au plating Silver alloy (Au plating type) Silver alloy (without Au plating type)

Nominal switching 7A 250V AC 5A 250V AC capacity Rating Max. switching power 1,750 VA 1,250 VA (resistive Max. switching voltage 250 V AC load) Max. switching current 7A 5A Min. switching current*9 1 V 1 mA (Au plating type only) Mechanical (at 180 cpm) 2 × 107 Expected 105 105 life (min. Electrical (at 20 cpm) (7A 250 V AC) (5A 250 V AC) operations) (resistive load) 5 × 105 2 × 105 (5A 250 V AC) (3A 250 V AC)

Coil Nominal operating power Remarks

0.9W 1.2V A

* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section *2 Detection current: 10mA *3 Excluding contact bounce time *4 For the AC coil types, the operate/release time will differ depending on the phase. *5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10µs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT *9 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load.

Max. operating speed Initial insulation resistance*1 Between open contacts Initial breakdown Between contact voltage*2 sets Between contact and coil Operate time*3 (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Temperature rise, max. (at 70°C) (at nominal voltage) Functional*5 Shock resistance Destructive*6 Vibration resistance

Functional*7 Destructive

Conditions for operation, Ambient transport and storage*8 temp. (Not freezing and condensing at low Humidity temperature) Without test button Unit weight Test button

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

2 Form C 4 Form C 20 cpm (at max. rating) Min. 100 MΩ at 500 V DC 1,000 Vrms for 1 min. 2,000 Vrms for 1 min. 2,000 Vrms for 1 min. Max. 20 ms*4 Max. 20 ms*4 60°C Min. 100 m/s2 {10 G} Min. 1,000 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1.0 mm 10 to 55 Hz at double amplitude of 1.0 mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Approx. 31g 1.09 oz Approx. 34g 1.20 oz

Approx. 32g 1.13 oz Approx. 34g 1.20 oz


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.