FEATURES n Motor Start Timer Star/Delta (⅄/Δ) (Wye/Delta) n Time setting t1 ⅄ (Star): Time range 0.1 second – 100 days 10 time ranges available n Coarse time setting by rotary switch n Time setting t2 (delay) between ⅄/Δ Time range 0.1 – 1 second n Fine time setting by potentiometer n Input voltage: AC/DC 12-240V n Relay output form: DPDT – 16 Amps n Output indicator: Red LED n DIN rail mounting n UL and CE approvals, RoHS compliant

10/15/08

SPECIFICATIONS Number of timing modes. . . 1 Input terminals. . . . . . . . . . . . . A1–A2 Input voltage. . . . . . . . . . . . . . . AC/DC 12–240V (AC 50/60Hz) Power consumption. . . . . . . . 3 watts max Input voltage tolerance. . . . -15% ­­to +10% Input indicator . . . . . . . . . . . . . Green LED Time ranges . . . . . . . . . . . . . . . . t 1: 0.1 second–100 days t2: 0.1–1 second

timing mode motor start timer star / Delta (WYE/DELTA)

Setting accuracy. . . . . . . . . . . . 5% mechanical accuracy Repeatability. . . . . . . . . . . . . . . 0.2% Relay output form. . . . . . . . . . DPDT

Input Voltage Terminals 15-18

otary switch and Time settings by. . . . . . . . . . . . R potentiometer

Rated current. . . . . . . . . . . . . . . 16A/ AC

t1

Switching capacity. . . . . . . . . 4000 VA/ AC, 384 W/ DC

t2

Terminals 25-28

star ⅄

delta Δ

Inrush current. . . . . . . . . . . . . . 30A / < 3s Switching voltage (max). . . . 250VAC / 24VDC Switching capacity DC (min). . 500mW Output indicator . . . . . . . . . . . Red LED Mechanical life . . . . . . . . . . . . . 30 million operations Electrical life (resistive). . . . . 70,000 operations Reset time (max). . . . . . . . . . . . 150ms Operating temperature. . . . -20°C to +55°C Storage temperature. . . . . . . -30°C to +70°C Dielectric strength . . . . . . . . . 4 kV Operating position. . . . . . . . . any Mounting. . . . . . . . . . . . . . . . . . . DIN rail EN 60715 Protection degree. . . . . . . . . . IP 40 from front panel Wire size (max) . . . . . . . . . . . . . 14AWG Standards . . . . . . . . . . . . . . . . . . E N 61812-1, EN 61010-1, UL, CE, RoHS

315-655-8476 n www.peltectimers.com


Peltec103

motor start TIMER star / Delta (wye/delta)

features

wiring diagram 16

A1

18

26

28

Input terminals

Input indicator

Output indicator A2

Coarse time setting t1 Fine time setting t1

15

Motor Starter

Fine time setting t2 A1

25

(Motor)

delta Δ

S1

S3

star ⅄

S2

A2

L1

Output terminals L2

25 26 28 15 16 18

Output terminals

Motor S1

2747 Route 20 East, Cazenovia, NY 13035 315-655-8476 n www.peltectimers.com

star ⅄

S2

delta Δ

L3

S3

10/15/08