Peltec Timers 351

Page 1

351

300 Series

current sensor

FEATURES n Current sensor n Universal input voltage: 24-240VAC and 24VDC n Choice of five AC current ranges: 351-1 – 0.1 to 1 Amp 351-2 – 0.2 to 2 Amps 351-5 – 0.5 to 5 Amps 351-8 – 0.8 to 8 Amps 351-16 – 1.6 to 16 Amps n Overcurrent sensing with 5% hysteresis when returning from fault condition n Adjustable time delay from 0.5 to 10 seconds eliminates nuisance tripping n Relay output form: SPDT – 8 Amps n Green LED indicates sensor is powered n Red LED indicates fault condition n Single-phase applications n DIN rail mounting n UL and CE approvals, RoHS compliant

mode of operation Hysteresis

10/15/08

SPECIFICATIONS Input terminals. . . . . . . . . . . . . A1–A2 4–240VAC (AC 50/60Hz), Input voltage. . . . . . . . . . . . . . . 2 24VDC Input voltage tolerance. . . . -15% to +10% Power consumption (max). . . 1.5VA Current connection. . . . . . . . . between B2–B1 Current ranges (AC) choose 1 of 5. . . . . . . . . . . . . . . . . . . 351-1 351-2 351-5 351-8 351-16

0.1 to 1 Amp 0.2 to 2 Amps 0.5 to 5 Amps 0.8 to 8 Amps 1.6 to 16 Amps

Permanent current (max). . . 351-1 351-2 351-5 351-8 351-16

1 Amp 2 Amps 5 Amps 8 Amps 16 Amps

Overload capacity (max) . . . 100A/1ms Current adjustment by. . . . . Potentiometer Time delay (adjustable) . . . . 0.5 to 10 seconds Setting accuracy. . . . . . . . . . . . 5%

When the sensed current increases above set point, the time delay starts. At the end of the delay the output is energized. When the current falls below set point, a 5% hysteresis occurs before relay transfers to NO condition.

Repeatability. . . . . . . . . . . . . . . <1% Set point tolerance. . . . . . . . . 5% Hysteresis (fault to normal). . . . 5% Relay output form. . . . . . . . . . SPDT Rated current. . . . . . . . . . . . . . . 8 Amps Switching capacity. . . . . . . . . 2500 VA/ AC, 240 W/ DC Output indicator . . . . . . . . . . . Red LED Operating temperature. . . . -20°C to +55°C Storage temperature. . . . . . . -30°C to +70°C Dielectric strength . . . . . . . . . 4 kV Operating position. . . . . . . . . any Mounting. . . . . . . . . . . . . . . . . . . DIN rail EN 60715 Protection degree. . . . . . . . . . IP 40 from front panel Wire size (max) . . . . . . . . . . . . . 10AWG

315-655-8476 n www.peltectimers.com

Standards . . . . . . . . . . . . . . . . . . E N 60255-6, EN 61010-1, UL, CE, RoHS


Peltec 351

current sensor

features Input terminals A1

Current sensing terminals (AC only)

A2 B1

B2

Output indicator Current setting in % Time delay

wiring diagram

40 30 20 10

50 60

Imax

70 [ % In] 80 90 100

L N

Current setting as % of range Overcurrent is indicated by relay transfer and red LED. A1

A2

16

18

Input Voltage

A1

A2

B1

B2

Sensed Current

16 16 0.5

15

18

Output terminals

2747 Route 20 East, Cazenovia, NY 13035 315-655-8476 n www.peltectimers.com

B1

B2

15

15

18

Time delay setting 0.5 to 10 seconds

10/15/08