Panasonic RX Relays

Page 1

RX (ARX)

RX RELAYS (ARX)

3 GHz SMALL MICROWAVE RELAY

• Insertion loss 20.5 .807

12.4 .488

0

9.4 .370

• V.S.W.R./ Return loss: 1.2dB or less/ 20.8dB or more 2. High sensitivity • Nominal operating power: 200 mW 3. Small size • Size: 20.5(L) × 12.4(W) × 9.4(H) mm .807(L) × .488(W) × .370(H) inch

mm inch

1. Excellent high frequency characteristics (~2.5GHz, Impedance 50W) • Insertion loss: 0.2 dB or less • Isolation: 60 dB or more

Insertion loss, dB

COM-NC 0.1

0.2 COM-NO 0.3

0.4

0.5 300kHz

1.5GHz

*Also available for unit support (contact us for more details).

2.5GHz3GHz

Frequency

SPECIFICATIONS Contact

Characteristics

Arrangement Contact material Initial contact resistance

Contact rating Rating Contact carrying power Max. switching voltage Max. switching current V.S.W.R. (Return loss) High frequency characteristics Insertion loss (~2.5GHz, Isolation Impedance 50Ω) Input power

Expected life (min. operations)

Mechanical (at 180 cpm) 10mA 24 V DC (resistive load) Electrical 10W 2.5 GHz, Impedance 50Ω, V.S.W.R.&1.2

1 Form C Gold Max. 100 mΩ 10W (2.5 GHz, Impedance 50 Ω, V.S.W.R.&1.2) 10mA 24V DC (resistive load) Max. 20W (at 40°C, V.S.W.R.&1.2, Average) 30 V DC 0.5 A DC Max. 1.2 (Min. 20.8dB) Max. 0.2 dB Min. 60 dB Max. 20W (at 40°C, V.S.W.R.&1.2, Average) 5×106 3×105

• Cellular phone base station (W-CDMA, FPLMTS, IMT-2000, PCS, DCS) • Cellular phone-related measurement devices (SP3T/SP4T switches, etc) • Wireless LAN • Wireless Local Loop

Release time (without diode) [Reset time]*3 Temperature rise (at 20°C)*4 Functional*5 Shock resistance Destructive*6 Functional*7 Vibration resistance Destructive

500 Vrms Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] Max. 60°C Min. 200 m/s2 {20 G} Min. 1,000 m/s2 {100 G} 10 to 55 Hz at double amplitude of 3 mm 10 to 55 Hz at double amplitude of 5 mm

Conditions for operation, Ambient transport and storage*8 temp. (Not freezing and condensing at low Humidity temperature)

–40°C to 70°C –40°F to 158°F 5 to 85% R.H. Approx. 5 g .18 oz

Remarks *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA *3 Nominal operating voltage applied to the coil, excluding contact bounce time. *4 By resistive method, nominal voltage applied to the coil: Contact carrying power: 20W, at 2.5GHz, Impedance 50Ω, V.S.W.R.&1.2 *5 Half-wave pulse of sine wave: 11ms, detection time: 10µs. *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10µs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT

Nominal operating power 200 mW 200 mW 400 mW

TYPICAL APPLICATIONS

Operate time [Set time]*3 (at 20°C)

Min. 100 MΩ (at 500 V DC) 500 Vrms 1,000 Vrms

Unit weight

105

Coil (at 20°C, 68°F) Single side stable 1 coil latching 2 coil latching

Initial insulation resistance*1 Between open contacts Initial Between contact and coil breakdown Between contact and earth voltage*2 terminal

ORDERING INFORMATION Ex.

A

Product name RX

RX Contact arrangement 1: 1 Form C

1

0 Operating function 0: Single side stable 1: 1 coil latching 2: 2 coil latching

Note: Standard packing; Carton: 50 pcs. Case 500 pcs. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

12 Coil voltage, V DC 03: 3 4H: 4.5 06: 6

09: 9 12: 12 24: 24