TA I E S H A E D W A R D S DESIGNPORTFOLIOv2 taiesha.edwards@yahoo.com
PROJECTSCREDITS VCU EVMS GRINNELL TCNJ CARLETON UNION
R. MCCLURE | B. CASTRO R. MCCLURE | J. SMITH | S. SOBBELL R. HARPER | M. DEMING M. BURNS | R. MULLEN M. BURNS C. KIRBY | B. TUCKER
BUILDING 216
A. SCOTT
DC ARCHIVES
B. CANNON | C. SULLIVAN
VU46 ROOFTOP LOUNGE
G. GUMUSYAN | L. SEMENYSHYN
CPW RESIDENCE
G. GUMUSYAN | L. SEMENYSHYN
FINANCIAL FIRM
G. GUMUSYAN | L. SEMENYSHYN | S. PITIERA
FACADE RESTORATION
G. GUMUSYAN
WEINGAST RESIDENCE
T. AHMANN | K. NORTH | W. DEVINE
REVITALIZATION
T. AHMANN
HIGHER EDUCATION PROJECTS
i
MIXED PROJECTS ii
REFERENCE LETTERS
iii
E D U C A T I O N P R O J E C T S ARCHITECTURE, PLANNING + URBAN DESIGN
i
V I R G I N I A C O M M O N W E A L T H UNIVERSITY City: Richmond, VA Type: Higher Education Budget: $87.3 million Gross: 154,000 s.f. Firm: EYP Architecture Term: 2015 - 2019 Contributions • Equipment + lab planning research will THERAPY lead to state of the PHYSICAL CLINICAL SKILLS LABS art facilities which will attract top scholars OFFICES and future contributors to Richmond’s elite healthcare force • First floor planning and dedicated areas STUDENT BREAK ROOM for transparency at the exterior skin promotes CLINICAL SKILLS connection between LABS students and staff with locals and visitors • The urban campus design of the public courtyard will allow for both an active pedestrian throughway and passive communal outdoor space
4
1
CW - PLAN 1/8" = 1'-0"
CLASSROOMS PHYSICAL THERAPY
LEVEL 8 269' - 0"
3
11/2/2015 4:28:18 PM
CW - ELEVATION 1/8" = 1'-0"
CW - 3D VIEW @ TOWER
Printed
2
CURTAIN WALL @ TOWER
EYP/
Virginia Commonwealth University
1
CW PUNCHED - PLAN 1/8" = 1'-0"
2
CW - PUNCHED ELEVATION 1/8" = 1'-0"
0'
1'
3'
5'
1/8" = 1'-0" 11/02/15
11/2/2015 5:16:35 PM
Programs Used • Revit, Lumion, Rhino3D, Photoshop, Illustrator, After Effects, Powerpoint, Excel, Newforma EYP/
CW - 3D VIEW @ WEST ELEVATION
PUNCHED CURTAIN WALL Virginia Commonwealth University
Printed
3
0'
1'
1/8" = 1'-0" 11/02/15
3'
5'
Render | Stacked Study CA Photos | Aerial Front + Courtyard Detail + Photo | Ribbed Precast Render + Elevation | Monumental Stair
E A S T E R V I R G I N I M E D I C A S C H O O
N A L L
City: Norfolk, VA Type: Higher Education Budget: $61.8 million Gross: 144,000 s.f. Firm: EYP Architecture Term: 2017 - 2021
Contributions • Tower planning and program test fits aligned with feedback at client committee meetings • Master plan site studies mapping vehicular versus foot traffic patterns to suggest opportunities for a carfree pedestrian way and a safer, more welcoming entry to campus • Massing studies in relation to neighborhood context • Vignette studies and coordination of exterior enclosure systems in accordance with value engineering cost analyses Programs Used • Revit, Enscape, Photoshop, Illustrator, Powerpoint, Excel, Sketchup
Rendered in-house on Enscape
GRINNELL C O L L E G E City: Grinnell, Iowa Type: Higher Education Budget: $100 million Gross: 175,000 sf Firm: EYP Architecture Term: 2015 - 2020
Contributions • Detailing the atrium connection - the new construction bridging the existing buildings to be renovated. • Corrections, markups, and production of roughly 20 new sheets to the construction documents permit set in roughly 4 weeks effectively assisting the initial project team. • Coordination of of feature wood slat ceiling with structural and MEP
Programs Used • Revit, InDesign Excel
EYP/
No No
SE-Chilled Water SE-Number SE-Load SE-Hardwir SE-NEMA SE-Lab of Phases Watts/Amps e or Plug Plug Config Water(hot/cold/tempered) Requirements
SE-Voltage
120/60/1
1.9
P
5-15P 5-15P
-
SE-RO or DI Water
-
-
SE-Drain (Direct/Indirect) SE-Gases
-
-
3,800 BTU/HOUR HEAT LOAD
8'-4" VIF
6' - 10"
7' - 2"
1/4" = 1'-0"
BIO LEVEL 1 0"
BIO LEVEL 1 0"
4"
LEVEL 1 0"
B143A SOUTH
13
B143-01
7' - 2"
B143-02
WB
3K EAST
Comments
EYP Architecture & Engineering of NJ, Inc. 225 Varick Street - 2nd Floor New York, NY 10014 Telephone 917 981 6000 Fax 917 981 6100
Yes No
SE-UPS
1/4" = 1'-0"
GENERAL NOTES: REFER TO A001 FOR ALL GENERAL NOTES, DEMOLITION KEYNOTES, & NEW WORK KEYNOTES. CONTRACTORS & SUBCONTRACTORS MUST REFER TO GENERAL NOTES & KEYNOTES PRIOR TO COMMENCING WORK ON THIS SHEET.
BIO LEVEL 1 0"
B143 EAST
9
B143 WEST
6
1/4" = 1'-0"
1/4" = 1'-0"
5
PROJECTION SCREEN
PB -XX
PEGBOARD LAB COAT RACK
ES-X
EMERGENCY SHOWER
6' - 10"
7' - 2"
GAS CYLINDER RESTRAINT
WB
WHITE BOARD - REFER TO A009
TB
TACK BOARD - REFER TO A009
CB
CHALK BOARD - REFER TO A009
LCD
LCD MONITOR. MONITOR IN SEPARATE BID PACKAGE. POWER, DATA, & WALL BLOCKING TO BE PROVIDED BY CONTRACTOR AS PART OF THIS PACKAGE. SEE AV DRAWINGS.
4"
BIO LEVEL 1 0" ES-__
1/4" = 1'-0"
8
2'-10"
B143A NORTH
10
1/4" = 1'-0"
H
NOTE: THERE IS AN ELECTRON MICROSCOPE IN THIS ROOM THAT WILL NEED TO BE REMOVED BY COLLEGE. BE AWARE THAT RADIATION SAFETY OFFICER WILL NEED TO COORDINATE REMOVAL AND UPDATE DISPOSITION WITH STATE.
F
36WSA
7
NEW SINK, EPOXY TOP & ADA CABINET
THIS SINK INSTALLATION TO SERVE AS A MOCK-UP. CONTRACTOR TO COMPLETE THIS INSTALLATION IN ITS ENTIRETY PRIOR TO PRIOR TO COMMENCING CONSTRUCTION OF OTHER NEW CASEWORK INSTALLATIONS
FILL GAP BETWEEN NEW WALL & EXISTING UPPER & LOWER CABINETRY WITH NEW WOOD INFILL PANELS CONSTRUCTED OF SALVAGED CASEWORK SCRAPS. INFILL ALL VISIBLE SIDES, INCLUDING UNDERSIDE OF UPPER CABINET. EXTEND COUNTERTOP TO BIO WALL LEVEL 1 & CONSTRUCT 0" SIDE BACKSPLASH USING SALVAGED COUNTERTOP.
B143 NORTH 1/4" = 1'-0"
E
D
C.3
C
B
A.2
New STEM Bldg
1'-7 1/2"
B143G 238 SF
LCD-01
B143H 133 SF
B143I 280 SF PROVIDE NEW FINISHED END PANEL
MEDICAL CAREERS & ADJUNCT OFFICE B143B 102 SF
B143C 102 SF 14
CLG MOUNTED PROJECTOR FIRE EXTINGUISHER LOC. FUME HOOD AFH: ADA FUME HOOD
WIDTH AtticX:EXIST: EXISTING HOOD
EXISTING CONSTRUCTION AND ROOMS TO REMAIN - N.I.C. NEW CONSTRUCTION EXISTING OR N.I.C. ELEMENTS (GREY) NEW OR RELOCATED ELEMENTS IN CONTRACT (BLACK)
PE1 PE2
3' - 0"
F.O. KEY PLAN:
4' - 6"
B143E 112 SF
S/F
RELOCATED EXISTING SNORKEL CONNECTED TO NEW DUCTWORK SEE 2/A650
Sim
A401
Open to Below
Seminar Stair
S/F DESCRIPTION F.O.
Computer Lab
Classroom
DATE
STEMF.O. COMPLEX PHASE 2 RENOVATIONS
B30A 15
Bldg. Support
The College of New Jersey 2000 Pennington Road Ewing, NJ 08628-0718
B143D 1 2
11
#
A401
FACULTY OFFICE
7230
B143D 108 SF
28
5.8
Stair FOR CONSTRUCTION
Core
REBEKAH A. DUNBAR
DATE:
WB
ST
6
11 AUGUST 2017 As indicated 1013016.02
SCALE: EYP PROJECT NO.: CLIENT PROJECT NO.: DESIGNED BY: DRAWN BY: CHECKED BY:
BIO - 1ST FL - ENLARGED PLAN
1/4" = 1'-0"
1
F.O.
Core
Elev. Core
F.O. 5.4
A140
8/11/2017
F.O.
28
F.O.
NORTH
Computer Lab
Classroom
Conf.
WB 13
F.O.
F.O.
B30A
6"
A140
CAPPED POINT EXHAUST
Core
Bldg. Support
MB TE TO
FILL GAP BETWEEN NEW WALL & EXISTING UPPER & LOWER CABINETRY WITH NEW WOOD INFILL PANELS CONSTRUCTED OF SALVAGED CASEWORK SCRAPS. INFILL ALL VISIBLE SIDES, INCLUDING UNDERSIDE OF UPPER CABINET. EXTEND COUNTERTOP TO WALL & CONSTRUCT SIDE BACKSPLASH USING SALVAGED COUNTERTOP.
2
AFH-X
Sim
7230
7230
WB
OFOI EQUIPMENT
FOR CONSTRUCTION
1
11' - 11" 12
A140 B30A
EQUIPMENT:
WSxxAyy xxyyy
A140
WB
B143E
B143K 263 SF
B143B
ADJUNCT OFFICE
WALL SHELF WIDTH WALL SHELF DEPTH
1
FACULTY OFFICE
OPEN TUTORIAL
Term: 2015 - 2021
PHONE OUTLET BLACK DOT INDICATING 48" A.F.F. (U.O.N.), SEE TA & AV DWGS, TYP.
CASEWORK DESIGNATION (ELEVATION)
Stair
WB
7230
DATA PORT BLACK DOT INDICATING 48" A.F.F. (U.O.N.), & AV INDICATING HDMI & VGA PORTS, SEE TA & AV DWGS, TYP.
F.O.
B30A
WB
BLACK DOT INDICATING 48" A.F.F. (U.O.N.)
ELECTRICAL RACEWAY
16
6" 6"
6" 6"
WBxxEyy
Firm: EYP Architecture
GFCI ELECTRICAL OUTLET SPECIAL POWER, SEE ELEC.
CONSTRUCTION TO DEMOLISH
5
B30A
HELIUM
EMERGENCY POWER
S
HEIGHT COUNTER MATERIAL E - EPOXY RESIN L - PLAM
WALL BENCH DEPTH
28
B30A
Gross: 300,000 s.f.
NITROGEN
DOUBLE DUPLEX ELECTRICAL OUTLET
WBxxEyy
7230
B143F
He
DUPLEX ELECTRICAL OUTLET
EM
A401
25
WB
B30A B143A
WB
2'-8 1/2" 2'-7 1/2"
REUSE CABINETS REUSE COUNTERTOP REUSE CASEWORK
B143C-01
B143J 150 SF 8
PROVIDE FINISHED END PANEL USING SALVAGED CASEWORK PANEL OR NEW TO MATCH EXISTING.
WALL BENCH
4
LOCATE WALL 3" FROM EDGE OF COUNTERTOP
WB
WB
8
B143A 109 SF
10'-8"
• • •
5' - 0" HOLD
8"
2'-6"
9 STUDENT STUDY
2'-7 1/2" 2'-8 1/2"
B143C
21 FROM ROOM B143
3
11' - 5"
B143-02
LCD-01
EM REF.
B143-01
ACCESS CORRIDOR
B133
8
A140A
WB30E36
7
A140
6
A140
EXISTING FLOOR BOX POWERING TABLE
REUSE SHELF FROM GEN. STOR.
FB1
5'-0"
10
3 5
STUDENT BENCH
LEGEND:
1
3"
EXIST
WB30E34
TB
NEW STAFF DIRECTORY
2'-6"
ES-2
B143 407 SF
21
HC
EW HC
DR. AMANDA NORVELL RL RELOCATE EXISTING TELEPHONE AND PHONE JACK
RESEARCH BENCH
SB____
3
A
B143F 169 SF
ALIGN
B143
SPECIALTY GAS, INERT
FACULTY OFFICE
FILL GAP BETWEEN NEW WALL & EXISTING UPPER & LOWER CABINETRY WITH NEW WOOD INFILL PANELS CONSTRUCTED OF SALVAGED CASEWORK SCRAPS. INFILL ALL VISIBLE SIDES, INCLUDING UNDERSIDE OF UPPER CABINET. EXTEND COUNTERTOP TO WALL & CONSTRUCT SIDE BACKSPLASH USING SALVAGED COUNTERTOP.
IMAGING
RB____ WB____
4.1
SEM
HYDROGEN ARGON
SG
WALL BENCH DESIGNATION (PLAN)
9 3/4"
Third Floor
VACUUM OUTLET OXYGEN N2
H2 Ar
CABINET WIDTH CABINET TYPE
Scheme D2 SUPPORT
COMPRESSED AIR OUTLET NATURAL GAS OUTLET
V O2
ELECTRICAL:
A30
1/4" = 1'-0"
BIO LEVEL 1 0"
A30
A WEST
EPOXY SINK
Budget: $87 million
COLD WATER PURE WATER OUTLET EYE WASH
A G
(M)T_____ LAB TABLE
3"
BIO LEVEL 1 0"
HW CW PW EW
CASEWORK:
7' - 2"
1/4" = 1'-0"
B143A EAST
12
SINGLE DECK MTD. FIXTURE 180° DOUBLE DECK MTD. FIXTURE 90° DOUBLE DECK MTD. FIXTURE 4-WAY DECK MTD. FIXTURE SINGLE PANEL/WALL MTD. FIXTURE 90° DOUBLE PANEL/WALL MTD. FIXTURE HOT WATER
LAB EQUIPMENT PROJECTOR
LC-XX
K WEST
PLUMBING:
EQUIPMENT & ACCESSORIES:
CR-___ WB
Type: Higher Education
SYMBOLS LEGEND: XXXX-XX PROJ. PS ___
9'-0" VIF
EL 1 0"
City: Ewing, NJ
eypae.com
EQUIPMENT SCHEDULE B143
xhaust SE-Emergency/ ements Standby Power
THE COLLEGE O F N E W J E R S E Y
BIOLOGY ENLARGED PLANS
Attic NJ REGISTERED ARCHITECT LICENSE NO. 19641
F.O. F.O.
Contributions • Phase 2 of the three phase STEM new, construction, addition, and renovation project • Teaching lab planning with programmed equipment • Ceiling coordination with cost alignment for areas with upgraded designs • Drawing plans, elevations, sections, and details for DD + CD submissions
A140
Programs Used • Revit, Photoshop, Illustrator, Powerpoint
CARLETON C O L L E G E City: Northfield, MN Type: Higher Ed. Research Budget: Gross: Firm: EYP Architecture Term: 2017
Contributions • Addressing the experience of both student and staff in their existing facility prior to new construction • Drafting questions, submitting for comments, previewing, and distributing surveys • Presenting ideas to better the finished product and aligned results between past and future research using similar evauation criteria
Carleton College Faculty Pre-Occupancy STEM Survey
Q21 During the past academic year, about how often have you met with students in one of the public spaces in Hulings, Olin, or Mudd (i.e., outside your classroom, lab, or office)? Answered: 25
Skipped: 8
Never
Once or twice
2-3 times a term About once a month 2-3 times a month About once a week More than once a week 0%
ANSWER CHOICES
Programs Used • Microsoft Word, Survey Monkey, Adobe
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
RESPONSES
Never
16.00%
4
Once or twice
8.00%
2
2-3 times a term
8.00%
2
About once a month
0.00%
0
2-3 times a month
16.00%
4
About once a week
16.00%
4
More than once a week
36.00%
TOTAL
9 25
U N I O N C O L L E G E City: Schenectady, NY Type: Higher Education Budget: $97 million Gross: 115,000 s.f. Firm: EYP Architecture Term: 2015 - 2020 Site Plan New Science & Engineering Center, Union College World’s Leading Liberal Arts College with Science and Engineering
SCHEMATIC DESIGN LAB CHECKLIST ASSIGN FACULTY
PLUMBING
DOORS 36" 42" 48" (36" + 12") 60" (36" + 24") 72" (36" + 36")
FURNITURE FIXED FLEXIBLE HEIGHT STANDING (36") SITTING (30") ADJUSTABLE ADA (34" - (1) STATION IN EACH LAB REQ'D)
c 2016 EYP Architecture & Engineering
ECE ADV TL #1 805 SF
ECE ADV TL #3 629 SF
ECE ADV TL #2 693 SF
DATA SPECIAL REQUIREMENTS?
VIBRATION SENSITIVE - YES
LASERS YES KEY PLAN:
CONSTRUCTION MANAGER
SITE/CIVIL ENGINEER
LAND SURVEYOR/GEOTECHNICAL SERVICES & HAZMAT CONSULTING
COST ESTIMATING
Turner Construction Company 1 Computer Drive South Albany, NY 12205 P: 518.432.0277 F: turnerconstruction.com
The Chazen Companies 547 River Street Troy, NY 12180 P: 518.273.0055 F: 518.273.8391 chazencompanies.com
C.T. Male Associates 50 Century Hill Drive Latham, NY 12110 P: 518.786.7400 F: 518.786.7299 ctmale.com
Danda Inc. 5 Davis Cort Albany, NY 12208 P: 518.489.4160 M: 518.369.4160 E: dandaestimating@aol.com
N
STEINMETZ
UNION COLLEGE
BUTTERFIELD
Floor Plan - Level 1 New Science & Engineering Center, Union College
EMERGENCY POWER UPS (TO BE PROVIDED BY USERS) CLEAN POWER LIGHTING
MECHANICAL FUME HOODS SNORKELS CANOPY HOOD PROCESS CHILLED WATER
CONSULTANTS:
EYP Architecture & Engineering 201 Fuller Road - 5th Floor Albany, NY 12203 Telephone 518 795 3800 eypae.com
ELECTRICAL 120V 208V 220V 240V 480V
SINKS HANDWASH DEEP UTILITY FLOOR DRAINS PURIFIED WATER YES POLISHING UNIT COMPRESSED AIR NATURAL GAS VACUUM CO2 MANIFOLD GAS SYSTEM
SEAT COUNT
01.21.2016 1/4" = 1'-0" 1013033.00 Designer Author Checker
OLIN
New Science and Engineering Complex
danda inc. cost estimating services WOLD
Notice: In accordance with New York State Education Law, it is a violation for any person, unless acting under the direction of a Licensed PE or Registered Architect, to alter these documents in any way. Any modification to these documents shall bear the seal of the altering professional engineer or architect with the notation "altered by" followed by his/her signature and the date of such alteration, and a specific description of the alteration.
DATE: SCALE: EYP PROJ. NO. DESIGNED BY: DRAWN BY: CHECKED BY:
Contributions • New construction phase of the two phase Science + Engineering Complex • Departmental space planning attentive to critical adjacencies for wet and dry labs • Strategizing physical and visual connections within the campus quad • Developing presenation material to supplement the construction documents for clear representation
S&E
Schenectady, New York
BAILEY
NO.
REVISION/SUBMISSION
LEVEL 1 - ECE ADV. TL 1, 2 & 3
P215
DATE
World’s Leading Liberal Arts College with Science and Engineering
Programs Used • Revit, Survey Monkey, Photoshop, Powerpoint
Lightwell Section
M
I
X
E
D
P
R
O
J
E
C
T
S
ARCHITECTURE, PLANNING + URBAN DESIGN
ii
V u 4 6 R o o f t o p L o u n g e The Hotel @ Times Square City: Manhattan, NY Type: Hospitality Budget: Low Firm: GGA Term: 2012 - 2013
Contributions • In NYC, rooftop lounges have gained popularity almost as fast codes regulating them for safety and egress spring up. • This rooftop lounge was a project that personally managed from conception, through construction materialization and over the many hurdles involved in building and fire code approvals. • It’s design is modest as per the client’s wishes but still pushes the expanse of creativity through features such as: the operable roof canopy, responsive lighting bar design and plant generated heated lounge seating.
Programs Used • AutoCAD, Rhino, V-Ray, Photoshop
O R T Y E R ILDING 2 1 6
4
5
US ARMY CORPS OF ENGINEERS
06 TYP
APPR.
BALTIMORE DISTRICT
01
D
DATE
04
06 TYP
02
DESCRIPTION
05
05
1
2
MARK
05
06 TYP
05
DATE
03
01 02 03
FCU
11 23
05
27
S-4 OFFICE S-1 STAFF OFFICE
27
06
15
101
115
27
ANTE ROOM
FCU
113
1 DN
A103
UP
FOYER
DN 05 07
2' - 10"
06
VESTIBULE
104
27
9' - 8"
VAV
4' - 10"
69' - 0" +/-
EXISTING MECHANICAL UNIT, CONDUIT AND PIPING ALONG WALL.
THESE ITEMS MAY BE REMOVED DEPENDING UPON EXTENT OF MECHANICAL SCOPE.
DEMOLITION DOOR KEY NOTES
A
04 05 06 07 08 09 10 11
ELEC CL 9 SF 300
17 18 19 20
1/4" = 1'-0"
STAIRWAYS PERMITTED TO BE UNENCLOSED WHERE SERVING ONE ADJACENT FLOOR 4' 0' 2' PER NFPA 101 43.10.4.7
21 22 23 24
25 27
GENERAL DEMOLITION NOTES
REMOVE AND REPLACE FLOOR FINISH, SUB FLOOR & WOOD FLOOR FRAMING REMOVE PORTION OF FLOOR TO RECEIVE NEW PARTITION / CHASE DISCONNECT AND REMOVE EXISTING 200A SERVICE ENTRANCE DISCONNECT SWITCH. CAP CONDUIT AND PREPARE EXISTING FEEDERS FOR REUSE. DISCONNECT AND REMOVE EXISTING GENERATOR DISCONNECT SWITCH. CONFIRM WITH FACILITY ENGINEERS PRIOR TO REMOVAL DISCONNECT AND REMOVE EXISTING 200A, 3P DISCONNECT SWITCH WITH ALL ASSOCIATED WIRING, CONDUITS AND WIRE TROUGH. REMOVE EXISTING PANELS “L2”, “LP1” AND “L3” WITH ALL ASSOCIATED FEEDERS, BRANCH CIRCUIT WIRES, CONDUITS AND CIRCUIT BREAKERS. REMOVE EXISTING PANELS “L4” AND “L5” WITH ALL ASSOCIATED FEEDERS, BRANCH CIRCUIT WIRES, CONDUITS AND CIRCUIT BREAKERS ACTIVE ELECTRONIC TELECOM EQUIPMENT SHALL BE REMOVED AND TURNED OVER TO THE FT. MYERS TELECOMMUNICATIONS DEPARTMENT VIA CONTRACTING OFFICER REPRESENTATIVE FOR STORAGE AND REUSE DURING NEW WORK PHASE. EXISTING CABLE ENTERING THE BUILDING SHALL BE PROTECTED IN PLACE AND RE-USED DURING THE NEW WORK PHASE. ANY CABLE ATTACHED TO THE EXTERIOR OF THE BUILDING AND ROUTING ALONG THE EXTERIOR OF THE BUILDING SHALL BE PROTECTED IN PLACE. REMOVE EXISTING FLOOR FINISHES. PREPARE TO RECEIVE NEW SUBSTRATE/FINISHES.
8'
PROJECT NORTH
DEMOLITION LEGEND
1. ALL INTERIOR DOORS TO BE REMOVED. UNLESS NOTED OTHERWISE.
EXISTING ELEMENTS TO BE REMOVED
2. DOOR FRAMES TO REMAIN UNLESS NOTED OTHERWISE.
OFFICE 1383 SF 100
DN
SUMMIT CONSTRUCTION AND ENVIORNMENTAL SERVICES, LLC 85'
6290 OLD WARWICK ROAD, SUITE D STORAGE RICHMOND, VIRGINIA 23224 75 SF 300 T: (757) 452-3113 1
CONFERENCE 545 SF 100
DOOR
3. REPAIR/REPLACE DAMAGED WOOD DOOR TRIM. PREPARE TO RECEIVE NEW PAINT.
EXISTING ELEMENTS TO REMAIN
max.
4. DIMENSIONS ARE APPROXIMATE.
400 0.15
AREA OF NEW FLOOR OPENING/CORE DRILL
60"
actual
19
FRONT PORCH AREA OF WORK
EYP ARCHITECTURE AND ENGINEERING, PC
TRUE NORTH
AD101
DN
110'
1000 POTOMAC ST, NW WASHINGTON, DC 20007 T: (202)471-5000
DOOR max.
34"
A
227 0.15 actual
19
PER IBC 303.1.2 SMALL ASSEMBLY SPACES CONFERENCE ROOM IS CONSIDERED GROUP B OCCUPANCY WITH OCCUPANT LOAD OF 6 BASED ON FURNITURE, OCCUPANT LOAD SHOULD BE 37
RESTROOMS / SHOWERS 399 SF 100
JANITOR CLOSET 18 SF 300
4
1
PROJECT SITE
NORTH
2
FIRST FLOOR LIFE SAFETY PLAN 1/8" = 1'-0"
BUILDING 216 RENOVATION
FORT MYER .
Programs Used • Revit, Enscape, Photoshop, Illustrator, Powerpoint, Excel, Sketchup
DESIGNED BY: AS
DATE:
04.20.2017
P
WASHINGTON, DC
VICINITY MAP
BALT
SHEET IDENTIFICATION NUMBER
UP
37
US A OF E
03
P
12 13 14 15 16 16.5
227 0.15
REMOVE EXISTING DAY LOCKERS AND STORE FOR REINSTALLATION REMOVE RUBBER FLOORING AND BASE. PREP SURFACES TO RECEIVE NEW FINISHES. GROUT AND REPAIR CONCRETE FLOOR REPAIR/REPLACE ROTTING WOOD LATTICE SCREEN actualAT BASE OF PORCH REFINISH ENTRY PORCH SURFACE, REPLACE ANY DETERIORATED WOOD. PRIME AND FINISH TO MATCH ADJACENT. REMOVE FLOOR & WALL FINISHES. PREPARE TO RECEIVE NEW SUBSTRATE/FINISHES REMOVE DAMAGED TREADS, BALUSTRADE, RAILINGS CARPET PADS AND NEWEL POST. WOOD FLOORING TO BE REMOVED AND REPLACED. REPLACE DOOR AND FRAME DOCUMENT/SURVEY AND REMOVE EXISTING PORCH STRUCTURE COMPLETE INCLUDING ROOF. DOCUMENT/SURVEY AND REMOVE EXISTING COLUMNS. DOCUMENT/SURVEY AND REMOVE EXISTING STAIRS REMOVE/CUT SECTION OF CONCRETE SILL/WATERTABLE, REMOVE NON-HISTORIC BRICK UNITS AND MORTAR. PREPARE WALL CAVITY TO RECEIVE NEW WORK REPOINT EXTERIOR MASONRY (100%) REMOVE ALL EXISTING PLUMBING FIXTURES AND ACCESSORIES EXTERIOR BASEMENT ACCESS DOORS TO REMAIN. EXISTING COUNTER & FLIP-UP COUNTER TO REMAIN. STRIP, PRIME & PREP PERIMETER SOFFIT TO RECEIVE NEW FINISH. REPLACE / REPAIR DAMAGED RAILING TO MATCH EXISTING.
34"
EXISTING CHILLER TO REMAIN
DEMOLITION KEY NOTES
max.
P
01 02
FCU
EYP PROJECT # 2016051.01
12
04.13.17
25 27
105
18
3' - 7"
3' - 6"
25 27
10
03 03.5
STAFF DUTY OFFICE
108
FCU
DN
B
27
MEN
1/8" = 1'-0"
25
5
100% DEMOLITION DOCUMENTS
VAV
04 13
REMOVE WALL FINISHES IN HATCHED AREA FOR STRUCTURAL INVESTIGATION
04 13
SEAL:
4
SOLICITATION NO.: W912DR−16−R−0049
3
CHECKED BY: TO
2
109
PLOT SCALE: 1:1
1
03
WOMEN
27
119
MARK
04 13
CONFERENCE ROOM
Contributions • Renovation to one of SECOND FLOOR LIFE SAFETY PLAN 3 many properties on BUILDING 216 RENOVATION U.S. Army Corps of FORT MYER Engineers’ grounds FIRST FLOOR DEMOLITION PLAN 1 ARLINGTON, VA • Demo Package revision 1 JOINT BASE MYER-HENDERSON HALL and preparation for ARLINGTON, VA 22211 submission U.S. ARMY CORPS OF ENGINEERS PROJECT NUMBER W912DR-16-R-0049 MRP 19 B • CD Package 65% CONSTRUCTION DOCUMENTS 14 EXITAPRIL 24, 2017 preparation including life safety drawing, floor and ceiling plans, EXIT roof plans, interior and DESIGN/BUILD CONTRACTORS ARCHITECTURE & ENGINEERING exterior elevations 6' - 7"
DN
107 2' - 10"
07
4"
SIZE: 22X34
24 10
APPROVED BY: GB
116
DRAWN BY: TE
CLOSET
117
FIRST FLOOR DEMOLITION PLAN
CLOSET
118
SHEET IDENTIFICATION NUMBER
03.5
1
04.20.2017
C
CLOSET
FCU
DATE:
34' - 10" +/-
C
07 08 09
11' - 1 1/2"
Term: 2016 - 2018
STORAGE 37 SF 300
STORAGE 19 SF 300
DATE
27
114
S-2 OFFICE
DESCRIPTION
23
09
DESIGNED BY: AS
08
A
CHIMNEY (NIC) FRONT PORCH ROOF BELOW RESIZE GUTTER/DOWNSPOUT SYSTEM TO INCREASE DRAINAGE CAPACITY, PROVIDE POSITIVE DRAOMAGE TO DOWNSPOUTS, PROVIDE FULL ICE/WATERSHIELD PROTECTIVE MEMBRANE AT STANDING SEAM ROOF REMOVE PAINT FINISH AT DORMERS, PREPARE PRIME AND PAINT TO MATCH EXISTING, REPLACE/RESTORE DAMAGED DORMER ITEMS 03 REPLACE SLATE ROOF SYSTEM, INCLUDING DAMAGED OR DETERIORATED SUBSTRATE, FLASHING, DRIP EDGES, CANTS, MEMBRANES, SNOW GUARDS AND OTHER ITEMS AS NECESSARY TO ALLOW NEW ROOF SYSTEM INSTALLATION. PROVIDE NEW ASHRAE-COMPLIANT INSULATION, REPLACE DAMAGED RAFTERS/TRUSSES TO MAINTAIN INTEGRITY OF THE STRUCTURE. REUSE EXISTING SLATE MIXED WITH NEW TO ACHEIVE HOMOGENOUS COLOR. REPLACE ALL GUTTER AND DOWNSPOUTS. REATTACH TO EXISTING DRAINAGE SYSTEM AT GRADE EXISTING ROOF VENTS, REFINISH, PRIME AND PAINT TO MATCH EXISTING REAR PORCH ROOF BELOW NEW METAL ROOFING LINE OF ROOF ABOVE - 3 1/4"CHIMNEYS AT REAR OF BUILDING REPOINT / REPAIR9'SMALL
39' - 0 3/4" +/-
Firm: EYP Architecture
04
BALTIMORE DISTRICT
BUILDING 216 RENOVATION FORT MYER JOINT BASE MYER-HENDERSON HALL ARLINGTON, VA 22211
ROOF NEW CONSTRUCTION KEY NOTES D
US ARMY CORPS OF ENGINEERS
APPR.
TRUE NORTH
DATE
PROJECT NORTH
DESCRIPTION
8'
MARK
4'
APPR.
2'
19 20
Einhorn Yaffee Prescott, Architecture & Engineering, P.C. 1000 Potomac Street, NW Washington, DC 200007 T: 202.471.5000, F:202.471.5050 www.eypae.com
0'
14
Summit Construction & Environmental Services, LLC 6290 Old Warwick Road Suite D Richmond, Virginia 23224 T: (757) 452−3113 www.summitconstructiones.com
1/4" = 1'-0"
04.24.17
1
5
57'
ROOF NEW CONSTRUCTION PLAN
ROOF NEW CONSTRUCTION PLAN
4
04.13.17
3
1
Gross: 2 stories
PLOT SCALE: 1:1
04
2
STORAGE 21 SF 300
EYP PROJECT # 2016051.01
P
EXIT
06 TYP
1
100% DEMOLITION DOCUMENTS
B
SIZE: 22X34
04.20.2017
01
APPROVED BY: GB
05
Budget: 3.7 million
SEAL:
DATE:
CHECKED BY: PG
02
SOLICITATION NO.: W912DR−16−R−0049
23
65% CONSTRUCTION DOCUMENTS
Type: Government
OFFICE 2275 SF 100
05
1
DRAWN BY: MK
1
DESIGNED BY: MK
ELEC 6 SF 300
05
Summit Construction & Environmental Services, LLC 6290 Old Warwick Road Suite D Richmond, Virginia 23224 T: (757) 452−3113 www.summitconstructiones.com
STORAGE 09 38 SF 300
06 TYP
D
PLOT DATE: 4/24/2017 4:22:32 PM
City: Arlington, VA
MARK
MRP
DESCRIPTION
05
07
04.13.17
05
04.24.17
1
BUILDING 216 RENOVATION FORT MYER JOINT BASE MYER-HENDERSON HALL ARLINGTON, VA 22211
05
65% CONSTRUCTION DOCUMENTS
STORAGE 11 SF 300
PER NFPA 7.2.8.1.2.1 FIRE ESCAPE STAIRS PERMITTED ON EXISTING BUILDINGS PROVIDED THEY DO NOT SERVE MORE THAN 50% OF REQUIRED MEANS OF EGRESS
100% DEMOLITION DOCUMENTS
APPR.
EXISTING FIRE ESCAPE TO REMAIN
C
3
03
05
PLOT DATE: 4/24/2017 4:23:01 PM
09
Einhorn Yaffee Prescott, Architecture & Engineering, P.C. 1000 Potomac Street, NW Washington, DC 200007 T: 202.471.5000, F:202.471.5050 www.eypae.com
08
B
A
3
Summit Construction & Environmental Services, LLC
C
F M BU #
2
EXIT
D
1
BUILDING 216 PROJECT SITE
LOCATION MAP
BUILDING 216 NORTH
ID
D I S T R I C T OF COLUMBIA ARCHIVES
RHODE ISLAND METRO STATION
NEIGHBORHOOD PRESENCE
NW
City: Washington, DC
E IS
OD
RH
AVE
D LAN
MCKINLEY TECHNICAL HIGH SCHOOL
Type: Government Study
IL RA TA MA
W
RK
W
NORTH CAPITOL NW
NE
YO
AVE
NE
Budget: $24,500
VISIBILITY FROM RAIL + NEW YORK AVE.
Sq. Ft.: -
NOMA-GALLUDET U METRO STATION
FLO
Firm: EYP Architecture RID
NOMA REDEVELOPMENT
A
AV E
Term: 2016 - 2017
NE
4 3 1
WARD
5
RA
ND
2
7 6
8
R PA
G KIN
OL
PH
PL
E
E
T. N
DS
3R
.N
Contributions • Analyzing zoning codes, site relationships, neighborhood context and pedestrian experience. • Developing graphics to be included in a feasibility report comparing multiple sites to house DC Archives. • Massing studies illustrating options for new construction and renovation
Programs Used • Revit, Photoshop, Illustrator, Powerpoint
Financial F i r m 410 Park Avenue
City: Manhattan, NY Type: Corporate Budget: High Firm: GGA Term: 2013
Contributions • Interior Corporate office renovations for Eastgate Reality clientele on Manhattan’s Park Avenue. • Measuring the floor spaces, developing space planning schemes, material research and selection, continued design development, and construction oversight. I attended meetings with city officials, consultants, engineers, and owners. • Also, I attained much skill in the production of technical electrical and power/data coordination.
410 PARK 100'-5"
N
116'-8"
410 PARK AVE. BL. 1290 LOT. 37 & 41 21- STORY 233'-5" H.
EAST 55TH STREET
AVENUE
PARK AVE.
KEY PLAN
1. ALL OUTLETS WITHIN 18" OF WATER SOURCE TO BE GFI. 2. REPLACE ALL EXISTING TELEPHONE CABLING TO NEAREST DISTRIBUTION POINT WITH NEW CAT 6 TELE/DATA CABLING. 3. ALL NEW AND EXISTING TELEPHONE/DATA OUTLETS ARE TO RECEIVE NEW CAT 6 CABLING WIRED AS "HOME RUNS" FROM NEW COMMUNICATIONS PULL BOX 4. ALL NEW CATV OUTLETS ARE TO RECEIVE NEW CO-AXIAL CABLING WIRED AS "HOME RUNS" FROM COMMUNICATION PULL BOX
No.
DATE
COMMENT
5. ALL NEW OUTLETS TO BE 1'-0" ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED. 6. ALL A/V CABLE TO BE INSTALL AND COORDINATE WITH A/V CONSULTANT UNLESS OTHERWISE NOTED. 7. ALL ELECTRICAL AND DATA WALL PLATE SHALL BE LUTRON DESIGNER STYLE COLLECTION. COLOR TO MATCH WALL. 8. ALL LIGHT SWITCHES SHALL BE MAESTRO COLLECTION IN WHITE TO MATCH WALL. A.
#MAF-6AM FOR FLUORESCENT DIMMERABLE
B.
#MAF-S6AM-277 - FLUORESCENT NON DIMMERABLE
C. D.
#MAELV-600 FOR ELECTRONIC LOW VOLTAGE #MAF-6AM -LED COVE LIGHT DIMMERABLE
9. MULTI SWITCH CONTROL SHALL BE LUTRON GRAFIK EYE QS. 10. CEILING MOUNTED SPEAKERS SHALL BE BOSS VIRTUALLY INVISIBLE 191 WITH MATCHING ROUGH-IN KIT. 11. 4 DATA PORTS AND 8 ELECTRICAL OUTLETS (2 QUADS) AT EACH LOCATION. 12. THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL TWO (2) NEW 120V/20AMP ISOLATED GROUND DEDICATED CIRCUIT IN A JUNCTION BOX WITH A NEMA 5-20R DUPLEX RECEPTACLE MOUNTED AT 18" AFF. 13. THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ONE (1) NEW 120V/20 AMP ISOLATED GROUND DEDICATED CIRCUIT IN A JUNCTION BOX WITH A NEMA 5-20R DUPLEX RECEPTACLE MOUNTED AT 18" AFF. 14. THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ONE (1) NEW 120V/20 AMP ISOLATED GROUND DEDICATED CIRCUIT IN A JUNCTION BOX WITH A NEMA 5-20R RECEPTACLE QUADPLEX. CIRCUIT TO BE MOUNTED TO OVERHEAD LADDER RACK, SEE RACK ELEVATIONS.
410 PARK AVE 22ND FLOOR RENOVATION AND UPGRADE
KORSANT PARTNERS, LLC
Programs Used • AutoCAD Power/Data & Furniture Plan
Reflected Ceiling Plan
SOUTH ELEVATION (WEST 72ND ST.)
NORTH ELEVATION (WEST 73RD ST.)
F a ç a d e Restoration Mayfair Towers
City: Manhattan, NY Type: Residential Budget: Average Firm: GGA Term: 2013 EAST ELEVATION (CENTRAL PARK WEST)
SOUTH ELEVATION (WEST 72ND ST.)
WEST ELEVATION
NORTH ELEVATION (WEST 73RD ST.) BRICK REPLACEMENT WORK
MAYFAIR TOWERS FACADE REPAIR 15 WEST 72ND STREET DATE: 06-12-2013
EAST ELEVATION (CENTRAL PARK WEST)
BALCONY RESTORATION (2003)
PARAPET RESTORATION
REPLACE BRICK/DECORATIVE BLOCK IN DRIVEWAY
Contributions • As per statutes of the NYC Department of Buildings, the client needed to restore the façade of a residential property. • Scope of work included evaluation of the existing facade & a plan for restoration to areas in need broken down into phases.
WEST ELEVATION
BRICK REPLACEMENT WORK
MAYFAIR TOWERS FACADE REPAIR 15 WEST 72ND STREET DATE: 06-12-2013
BALCONY RESTORATION (2003)
PARAPET RESTORATION
REPLACE BRICK/DECORATIVE BLOCK IN DRIVEWAY
Programs Used • AutoCAD, Photoshop
W e i n g a s t Residence City: Chevy Chase, MD Type: Residential Budget: High Firm: Ahmann, LLC Term: 2013 - 2014
21'-1"+/- (ALIGN W/ GARAGE BELOW)
W3924
cabs
CL FAM. RM.
CLWINDOW
RENDERING
W3924
W3924
cabs
W3924
CL
1x1
24 GRAFTON STREET, CHEVY CHASE, MD 20815
WM-623 CM8-NG STR8
FLUSH SLATE HEARTH
LIVING
COFFERROOM DETAIL AT BULKHEAD
2
Scale: 2" = 1'-0"
NEW CROWN MOULDING, CHAIR RAIL, & PICTURE FRAME PANEL MOULDING
FAMILY RM
GRILL
1'-6"
LWM-46
BLOCK AS REQ.
CL
3
ALIGN
B18
+/- 1" FILLER
B36
48" RANGE
BD18
BD18
PROVIDE MATCHING KICKSPACE
WHMM4819
W2742
DW
SB36
6'8" 2'-6" x 6'-8"
cubbies
E.Q. 'A'
W3924
TAMBOR CAB. BELOW W/ BK SHLVS ABOVE
+/- 1" FILLER
BWB18
W3348
(No Doors @ Bottom; Matching Interiors)
BUTLER'S PANTRY +/- 2" FILLER
+/- 1" FILLER
DDO3624FHK (21"D) W3348 (9" DEPTH)
DDR1824
W1842
(3) U181896
E.Q. 'A'
Matching End Panel
BASE & CAP TO MATCH EXISTING (TYP.) DDO1524
W1542
(3) U181896 (18" Custom Depth)
desk
(2) DFD1524 W3348 O33
ELEVATION 'A' OPTIONS AT FAMILY ROOM Scale: 1/2" = 1'-0"
EQ
NO CROWN TRIM AT KITCHEN & PANTRY WINDOWS. TYP. OF 3
FIRST FL PLAN
CL EQ
EQ
CM8-NG STR8
CL EQ
BID &
04 F
W3348
O33
W3348 (9" Depth Verify w/ Bumpout)
TS33
(CUT DOWN TO FIT)
WINDOW W/ NEW TRIM
MATCHING END PANELS
DDO3624-FHK (21" Depth Verify w/ Bumpout)
+/- 2" FILLER
2
W1842
W3348
TS33
(CUT DOWN TO FIT)
V48AR (2) DFD1524
WHMM4819 (VERIFY W/ HOOD)
+/- 1" FILLER
DDR1824 DDO1524 -FH
+/- 3" FILLER
ELEVATION 'B' AT KITCHEN & BUTLER'S PANTRY Scale: 1/2" = 1'-0"
ALL CABINETS SUBJECT TO FIELD MEASUREMENT/VERIFICATION AFTER ROUGH FRAMING OF ADDITION.
W1542
W3042
+/- 3" FILLER
BWB18
W3042
HOOD
W1842
W1542
TILE BACKSPLASH T.B.D. BLR8
SB36
DW
+/- 3" BASE END PANEL BEP3R
BD18
+/- 3" FILLER
BLR8
48" RANGE
EXTEND STONE BACKSPLASH UP TO MEET WINDOW STOOL
BD18
24" BEV. CTR.
+/- 1" FILLER
B36
B18
+/- 3" FILLER
ADDITION & RENOVATION
ALL CABINETS SUBJECT TO FIELD MEASUREMENT/VERIFICATION AFTER +/- 1" FILLER EXIST. ROUGH FRAMING OF ADDITION.
WEINGAST RESIDENCE
Scale: 3/8" = 1'-0"
17 1/4" +/-
1
+/- 1" FILLER
W1542 W2742
W1842
1
24" WINE REF.
KITCHEN
4'-5"
pantry
W3924
FIREPLACE T.B.D.
4'-0 1/2"+/-
EQ
INTERIOR
W3924
ALIGN
2'-0"
U361896
ALIGN
2'-3"
W3924
4'-2"
CL ISLAND
36" REF
U361896 (18" Custom Depth)
Matching End Panel
ELEVATIONS
MICRO. B18LFWT SB18 BWB18 BMC272434
POWDER EQ ROOM
5'-3 1/2"+/-
3'-9"
MANTLE T.B.D. SURROUND T.B.D.
DINING
Scale: 2" = 1'-0"
STR8
3'-0" x 6'-8" C.O.
2'4" x
WINDOW & DOOR TRIM TO MATCH EXIST. TYP.
U212496 RTC392496
2" x 2" STL TUBE SUPPORT CROWNW/ T.B.D. VALENCE
ALIGN
CL HALL
U212496
I-1
CL WINDOW
I-1
4'-0" x 6'-8"
CL WINDOW
3
COORDINATE REFRIGERATOR SELECTION W/ DEPTH OF WALL RECESS, VERIFY CM8-NG
1'-6" 2
COFFER DETAIL UP
DN
1x6
LINE OF EXISTING GARAGE BELOW
BD30-3
Programs Used • AutoCAD, Photoshop
LWM-46
PROPOSED ELEVATION 36" DIRECT VENT GAS FIREPLACE T.B.D.
WEINGAST RESIDENCE 7 1/4"
CL WINDOW
1'-6"
Contributions • Extensive property addition, full interior renovation, and exterior restoration project in suburban Maryland. • Ground floor kitchen expansion, living room renovation, as well as added auxiliary spaces. • During the Construction Administration phase, this project gave me a feel for proportions on paper versus in the field, for more expansive spaces.
I
A
BID & PERMIT IS
04 FEBRUARY 2
I-2
Ahmann LLC © 2014
C e n t r a l P a r k W e s t Residence City: Manhattan, NY Type: Residential Budget: Average Firm: GGA Term: 2012
Contributions • Interior high-end apartment renovations on New York City’s Upper West Side. • The confines of this duplex apartment were rather limited so it was important to redefine circulation and expose comfortable spaces. • The ability to document surveys of interior spaces proportionally turned out to be quite a time-saving attribute to the deadline.
Programs Used • AutoCAD, Rhino, Vray Site Survey - 1st Floor
Duplex Proposal Plans
Neighborhood Revitalization HIP Homes County: PG County, MD Type: Residential Budget: Very Limited Firm: Ahmann, LLC Term: 2013 - 2014
Contributions • The Housing Initiative Partnership is an innovative, green nonprofit developer dedicated to revitalizing neighborhoods and removing blight. • Worked closely with developers on several homes from schematic through construction phases, always finding ways to reduce cost and maintain quality. • Analyzed zoning, code compliance coordination, construction, demolition, and landscape plans, kitchen and bathroom renovation details, structural plans coordinated with the engineering consultant, and rendered images displayed at countywide events.
Programs Used • AutoCAD, Photoshop
R E F E R E N C E L E T T E R S P R O F E S S I O N A L + A C A D E M I C
iii
TAI E SHA E DWA RDS ARCHITECTURAL DESIGNER & URBAN PLANNER
QUALIFICATIONS
taiesha.edwards@yahoo.com cell: (240) 475 2389
• Licensure: 2 exams remaining; IDP complete • Proficient in: Revit, AutoCAD, Photoshop, InDesign, Illustrator, After Effects Lumion, Enscape 3D, Rhinoceros 3D, Microsoft Excel, Newforma
• AIA Associate Member
EDUCATION Pratt Institute Institute for Advanced Architecture of Catalonia
• Bachelor’s of Architecture | May 2012 | New York • Master’s of Advanced Architecture | June 2015 | Barcelona Urban Design Research Topic: Intelligent Cities
WORK EXPERIENCE EYP Architecture Washington, D.C. Architectural Designer Aug. 2015 - Present www.eypae.com
Mellissa Burns, Architect + Performance Reviewer | mburns@eypae.com Collaborated full-time on two new building projects for the Higher Education Sector in addition to mid-phase assists on several other project teams. Ability to work quickly and efficiently led to assignments with accelarated design-construction schedules. Involved in research, planning and campus site design. Other assets include: graphic diagrams, in-house renders, thorough coordination and quality drawing sets.
Ahmann Architects, LLC University Park, MD Architectural Intern Nov. 2013 - Sept. 2014 www.ahmanllc.com
Thomas Ahmann, Principal | tahmann@ahmannllc.com | (301) 864 1334 Worked on civic, residential and community revitalization projects from SD through CD with some exposure to bidding, permittng, and general CA. Contacted vendors for material samples, consultants for engineering requirements, city departments for permit administration, and clients for design coordination. Collaborated with Junior and Senior designers.
GGA Architecture, PLLC New York, NY Project Designer May 2011 - Aug. 2013 www.ggany.com
Garo Gumusyan, Principal | garo.aia@ggany.com | (212) 765 6335 Conceptualized and executed plans, elevations, sections, and renders for residential, commercial, corporate and hospitality projects. Managed small design team from schematic design through construction document phases and trained new employees. Worked closely with R.A. Garo Gumusyan and project consultants in the client review and DOB approval processes.
Grimm & Parker Architects Calverton, MD Work Study Intern Aug. 2006 - June 2007 www.grimmandparker.com
Churchill Banks III, Mentor | cbanks@asg-architects.com | (410) 627 2714 Worked on shop drawing markups, archiving drawing sets, presenta�on boards, inventory, and clerical assignments. A�ained skills in effec�ve oral and written communication regarding technical subjects. Produced a research practicum selected for an institution-wide presentation.
AFFILIATIONS
provided upon request
• Cosmo Couture - Most Creative Award | September 2016 • Architecture in the Schools - Teaching Program | January 2016 - March 2016 • Barcelona / Hong Kong Urban Exchage Platform | March 2015 • Roma 20-25 Exhibit @ the Maxxi Museum | January 2015 - July 2015 • Master’s Thesis Project – Data & City Award | June 2015 • Architecture for Humanity NY | March 2013 - August 2013 • Urban Studios of Brooklyn | July 2011 - August 2011