Digital Lumens LightRules Web Application

Page 1

LightRules Product Specifications ™


LightRules™

Product Overview One of the largest energy costs for any facility is expensive, inefficient lighting that is always left ON. Take control of lighting-related energy use to improve operations and the bottom line. MAXIMIZE LIGHTING EFFICIENCY LightRules™, part of the Digital Lumens Intelligent Lighting System, is a lighting management system that maximizes energy efficiency. By integrating robust controls with Intelligent Light Engines (ILEs), LightRules gives commercial and industrial staff unprecedented levels of management ability and operational insight. The end result? Dramatically reduced lighting-related energy use. Featuring an easy-to-use, web-based interface, LightRules enables lighting to be treated as a managed resource, controlling operating hours and energy use, and providing informative daily reports. TAKE CONTROL OF LIGHTING True lighting control means managing all lighting, either individually or facility-wide, so that illumination provided matches a facility’s needs. This means taking a new approach and specifying exactly what any given light does at a given time on a given day. Every decision about lighting behavior makes a material impact on lighting costs. LightRules gives facility staff the ability to make those choices — per fixture or on any group of fixtures — in order to maximize energy efficiency. All without ever getting on a scissor lift to push buttons, re-set DIP switches, or run low-voltage wiring. GAIN VALUABLE INSIGHT In addition to providing complete control over lighting, LightRules delivers informative reports on all aspects of lighting system performance. How much energy have the lights used in a particular shift, day, or month? What are peak activity times of the day or week? With easy access to this data, facility managers can evaluate the lighting program, provide measurement and verification data to their utility, and determine what modifications they need to make to ensure optimal energy usage. TURN LIGHTING INTO A MANAGED RESOURCE Armed with the ability to control lighting and access detailed operational reports, lighting becomes a resource to manage, not just a cost driver on the monthly utility bill. When facility managers can see the results, they can fine-tune lighting settings to match the facility’s needs. Is there a seasonal shift in the business? What needs to be done to the lighting program to accommodate it? With LightRules, making those incremental modifications is a matter of a few mouse clicks, rather than a laborious and time-consuming chore, and can make a significant impact on the energy bill.

2

LightRules™ from Digital Lumens

LightRules provides unprecedented levels of control and insight

FEATURES AND BENEFITS • Control — Easily manage individual ILE fixtures and groups of fixtures — settings, behaviors, light levels, and more. • Ease of Use — The web-based interface offers simple dashboard control, with at-a-glance system updates and a suite of robust reporting tools. • Security — LightRules ensures secure, password-protected control of ILE fixtures from any computer on the facility network. • Scheduling — Flexible scheduling automatically adjusts lighting delivery according to variations in shifts, downtime, holidays, and more. • Reporting — The reports display energy usage, energy cost, and occupancy data at multiple levels of granularity. • Maximum Energy Efficiency — A LightRules-enabled Intelligent Lighting System delivers unprecedented lighting-related energy savings.


The LightRules Web Application SOFTWARE OVERVIEW The LightRules web application is easy-to-use lighting management software accessible from any web browser connected to the facility network. The web application offers the following features via an intuitive interface: • Manual Lighting Control • Scheduled Lighting Control • Standard and Custom Report Templates • Secure User Administration • Diagnostic Tools THE LIGHTRULES DASHBOARD As the main page of the web application, the dashboard provides instant access to lighting controls, reporting, basic configuration options, and administration settings. REPORTING LightRules reports include a suite of tools for graphing and understanding Intelligent Lighting System energy usage, energy cost, and occupancy patterns. Use pre-configured report templates or create custom formats to suit your needs. You can also export data for analysis in other systems.

The dashboard provides a top-level summar y of key system information

CONFIGURATION LightRules configuration contains the scheduling feature, fixture settings, room setup, and more. Use LightRules configuration to optimize your Intelligent Lighting System. MANUAL CONTROL The manual control feature enables real-time override of fixture settings per fixture or for a group of fixtures. This feature accommodates one-time events like unexpected facility maintenance and demandresponse calls. ADMINISTRATION LightRules administration contains system-level settings including user accounts. For secure access control, the LightRules web application includes role-based user access, customizing lighting control to specific users.

Report templates provide insights into energy usage trends, energy cost over time, and occupancy data

Web Browser Compatibility • • • •

Internet Explorer® version 7.0 or higher Firefox® version 3.6 or higher Chrome version 7.0 or higher Safari version 5.0 or higher

Custom reports offer additional levels of reporting flexibility

Product Specifications  3


LightRules Network Infrastructure INFRASTRUCTURE OVERVIEW The LightRules network infrastructure enables communication and data transfer between Intelligent Light Engines, the LightRules Appliance, and the facility network. For performance and security purposes, LightRules requires installation of an Ethernet network dedicated solely to the lighting system. Power over Ethernet (PoE) networks, which deliver electrical power to the LightRules Network Gateways, are preferred for most deployments. PoE eliminates the need for an electrical service at each Gateway location, simplifies setup, and reduces system cost. Optionally, a non-PoE network can be deployed, requiring an AC-DC power supply (ordered separately) for each LightRules Network Gateway.

LIGHTRULES NETWORK GATEWAYS LightRules Network Gateways create a network bridge between the Ethernet components in the LightRules network infrastructure and the wireless Intelligent Light Engine (ILE) fixtures. Each Gateway manages communications for up to 50 fixtures within RF range. r

ity

CP

tiv

Ac

DH

Ne

Po we

k

r

ity

CP

tw or

tiv

we

LightRules ™ Network Gateway

Ac

DH

Po

Ne

tw or

k

LIGHTRULES WEB APPLICATION The LightRules web application is accessible via any supported web browser connected to the facility network.

Item: SN:

31200

0200000E

Contains FCC ID: U6TZIGBIT-B0 The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.

07-10

LightRules ™ Network Gateway

Item: SN:

LIGHTRULES APPLIANCE

Contains FCC ID: U6TZIGBIT-B0 The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.

07-10

The LightRules Appliance is the hear t of the LightRules network infrastructure. The Appliance hosts the software engine, serves the web application, and manages the dedicated LightRules network. The Appliance connects to the facility network from a secure, central location. A UPS (Uninterruptible Power Supply) is included as part of the LightRules Appliance Kit.

LightRules Appliance

31200

0200000E

TCP/IP ETHERNET COMPONENTS PoE (Power over Ethernet) switches and Ethernet cables connect the Appliance to the Gateways. PoE switches also supply electrical power to the Gateways. Note that LightRules is compatible with nonPoE Ethernet switches, if PoE functionality is not desired.

NETWORK EXAMPLE Dedicated LightRules Network (Ethernet Cat-5/5e/6 cable and Zigbee®/802.15.4 wireless) Facility Network (Ethernet) Electrical Power

Room One

Item: SN:

31200 0200000E

Contains FCC ID: U6TZIGBIT-B0 The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.

07-10

LightRules ™ Network Gateway Item: SN:

31200 0200000E

Contains FCC ID: U6TZIGBIT-B0 The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.

07-10

k r

ity

or

CP

tw

tiv

we

Ac

DH

LightRules Network Gateway

Ne

r

ity

or tw

tiv

we

Ac

DH

Ne

CP

k

LightRules Network Gateway

Wireless Network Three:

Up to 50 Intelligent Light Engines

Po

k r

ity

or

CP

tw

tiv

we

Ac

DH

Ne

Po

LightRules ™ Network Gateway

Wireless Network Two:

Up to 50 Intelligent Light Engines

Po

Wireless Network One:

Up to 50 Intelligent Light Engines

Room Two

LightRules ™ Network Gateway Item: SN:

31200 0200000E

Contains FCC ID: U6TZIGBIT-B0 The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.

07-10

LightRules Network Gateway 110-120 VAC

PoE Switch 328 ft (100 m) maximum

110-120 VAC PoE Switch 110-120 VAC Uninterruptible Power Supply

LightRules Web Application

LightRules Appliance

LightRules Appliance

4  LightRules™ from Digital Lumens

Facility Network


LightRules Appliance Kit Specifications PRODUCT OVERVIEW The LightRules Appliance is a small form factor server designed for industrial and commercial environments. The Appliance hosts the software engine, serves the LightRules web application, and manages the LightRules network infrastructure.

LightRules Appliance Kit Contents • LightRules Appliance with power cable • UPS (Uninterruptible Power Supply) with power cable • CAT-5 Ethernet Cable 3 ft (1 m)

LOAD

ON BATT

SENSITIVITY

LOW

ESTIMATED RUN TIME IN MINUTES

LIGHTRULES APPLIANCE

IN OUT LOAD

11.3 in

% Hz kWh

7.5 in

12.7 in

3.4 in

12.2 in

LightRules Appliance Hardware Specifications

UPS Hardware Specifications

ENVIRONMENTAL

ENVIRONMENTAL

3.6 in

Operating Temperature Range

50° to 95° F (10° to 35° C)

Operating Temperature Range

32° to 104° F (0° to 40° C)

Operating Humidity

20 to 80% RH (non-condensing)

Relative Humidity

0 to 95% RH (non-condensing)

ELECTRICAL Power Supply Rating

ELECTRICAL 235 W (42.8 W minimum per ENERGY STAR Version 5.0 “idle” mode)

AC Input Voltage Range

90-264 VAC

AC Input Current Max

3.5 A

AC Input Frequency

47-63 Hz

CERTIFICATION AND WARRANTY Certification

ENERGY STAR Version 5.0 compliant

Warranty

3-year Limited Warranty

Safety

NFPA, NRTL, CE, TÜV, NOM, and others

EMC

FCC Class B, CE Class B, C-Tick Class B, ICES Class B, and others

NETWORKING AND STORAGE (2x) Ethernet Ports

RJ45: Connects to LightRules network

Output Power

700 VA/420 W

Output Voltage (on utility)

120 VAC

Output Frequency (on utility)

60 Hz

Output Voltage (on battery)

115 VAC, +/- 8%

Output Frequency (on battery)

60 Hz

Input Voltage

120 VAC

Input Frequency

50/60 Hz, auto-sensing

Input Current (maximum)

12 A

Battery Type

Sealed, lead-acid, maintenance-free

CERTIFICATION AND WARRANTY Certification

FCC Part 15 Class B, FCC Part 68, NOM, UL 1778, RoHS, REACH: Contains No SVHCs

Warranty

3-year Repair or Replace Warranty

RJ45: Connects to facility network *

Data Rates Supported

10/100/1000 Mbps

Hard Drive Storage

500 GB

PHYSICAL Dimensions (H x W x D)

11.3 x 3.4 x 12.7 in (28.9 x 8.5 x 32.2 cm)

Weight

13.0 lbs (5.9 kg)

PHYSICAL Dimensions (H x W x D)

7.5 x 3.6 x 12.2 in (19.0 x 9.1 x 31.0 cm)

Weight

15.7 lbs (7.1 kg)

ORDERING INFORMATION Kit Item Number

31300

* T he LightRules appliance requires a static IP address.

Product Specifications  5


LightRules Network Gateway Specifications PRODUCT OVERVIEW The LightRules Network Gateway is the device through which the LightRules Appliance communicates with Intelligent Light Engine (ILE) fixtures. A single Gateway manages communications for up to 50 ILE fixtures within RF range.

.4 in

.4 in 5.6 in 6.0 in

k y it or P er w iv C w et ct H A Po N D

31200

LightRules ™ Network Gateway

0200000E

07-10

• Outbound commands from the LightRules Appliance are formatted and transmitted to the fixtures via Zigbee/802.15.4 wireless mesh networking. • Inbound data from the ILE fixtures is packaged and delivered via the Ethernet TCP/IP network to the LightRules Appliance.

SN:

3.8 in

Contains FCC ID: U6TZIGBIT-B0 The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.

NETWORK PROTOCOL TRANSLATION The Gateway’s TCP/IP-to-ZigBee ® onboard translation engine processes data and commands for two-way communication:

Item:

DESIGNED FOR DEMANDING ENVIRONMENTS Rated for temperatures of -40° to 122°F (-40° to 50°C), the Gateway operates in the most demanding commercial and industrial environments, including cold storage and high ambient temperature locations. Using widely available hardware,*  t he Gateway housing mounts rapidly to ceiling structures, walls, and suitable vertical surfaces.

6.4 in

FLEXIBLE POWER OPTIONS The Gateway is a PoE (Power over Ethernet) device, eliminating the need for power service installation. An optional low-temperature AC-DC power supply is available when PoE functionality is not desired (see page 8).

100M

12–48VDC, 3W

Link

1.4 in

+ PoE Port

3.8 in Antenna

.9 in 2.5 in

USB

2.0 in

NETWORKING AND CONTROL

ENVIRONMENTAL IP Rating

IP30

Storage Temperature Range

-40 ° to 122° F (-40° to 50°C)

Operating Temperature Range

-40 ° to 122° F (-40° to 50°C)

ELECTRICAL Standard Power Source

PoE (Power over Ethernet)

Overvoltage Protection

Integrated surge protector

Component Protection

Electrical isolation

Optional Power Source

Low-temperature AC-DC power supply (ordered separately, see page 8 for details)

DC Power Input for Optional Power Source

12-48 VDC, 3 W terminal block

CERTIFICATION AND WARRANTY Certification

FCC Part 15 Class A

Warranty

5-year Limited Warranty

* Mounting hardware not included.

Wireless Networking

Intelligent Light Engine ZigBee-Compliant Platform/802.15.4

Network Integration

IPv4 Ethernet

Programming

Via Ethernet

PHYSICAL Enclosure

ABS polymer, IP30

Radio Antenna

External swivel, SMA

Connectors

• SMA antenna • RJ45 Ethernet (PoE/non-PoE) • Screw terminal DC power input • USB type B

Status LEDs

• Power (blue) • Network connection (green) • DCHP (yellow) • Network activity (red)

Dimensions (H x W x D)

1.4 x 3.8 x 6.4 in (3.6 x 9.7 x 16.3 cm)

Mounting Hole Spacing*

(2x) centerline, 6 in (15.2 cm) apart

Mounting Hole Diameter*

.19 in (5 mm) diameter

Weight

.48 lbs (218 g)

ORDERING INFORMATION Standard Item Number

6  LightRules™ from Digital Lumens

31200 (PoE Powered)


Approved Ethernet Components PRODUCT OVERVIEW PoE (Power over Ethernet) switches are preferred for most LightRules deployments, as they supply electrical power to the LightRules Gateways. The following PoE switches are approved by Digital Lumens for standard temperature and low-temperature environments. STANDARD POE NETWORK SWITCH The NETGEAR FS108P * Ethernet switch is approved for use in standard temperature environments ranging from 32° to 104° F (0° to 40° C). A NETGEAR external power supply is included with this item.

LOW-TEMPERATURE POE NETWORK SWITCH KIT The N-TRON 105TX-POE * Ethernet switch is approved for use in low-temperature environments ranging from -40° to 185° F (-40° to 85° C). An XP Power DNR60US48-JDI001 low-temperature AC-DC power supply is included when ordering this kit (see next page for power supply details).

9.3 in NETGEAR ProSafe POE Switch FS108P

3.5 in

POE Ports

100M 10M

On = Link, Blink = Act

POE Active

PWR

1

2

3

4

POE Fault

1

2

3

4

5

6

7

8

105TXPOE

1.1 in 3.8 in

10/100 UPLINK

V1 V2

-V -V +V +V DC OK

LINK ACT

5 SPD 100

POE

3/4 LINK ACT POE

1/2 LINK ACT

N

L

4.1 in

DNR60US48-JDI001 (see next page for specifications)

1.5 in FS108P

ENVIRONMENTAL

N-TRON 105TX-POE

ENVIRONMENTAL

Operating Temperature Range

32° to 104° F (0° to 40°C)

Operating Temperature Range

-40° to 185°F (-40° to 85°C)

Operating Humidity

90% maximum RH (non-condensing)

Operating Humidity

95% maximum RH (non-condensing)

ELECTRICAL

ELECTRICAL

External Power Supply Input Voltage

120 to 240 VAC, 50/60 Hz

External Power Supply Input Voltage**

85 to 264 VAC, 47 to 63 Hz

Switch Input Voltage

48 VDC

Switch Input Voltage**

46 to 49 VDC

Power

44 W maximum

Power

77 W maximum

PoE 802.3af Power Consumption

32 W maximum (Ports 1-4), 48 VDC, 0.8 A power output

PoE 802.3af Power Consumption

32 W maximum (Ports 1-4), 48 VDC, 0.8 A power output

Power Cord Length (including power brick)

12 ft (3.7 m)

NETWORKING AND CONTROL Networking Connectors

(8) RJ-45 ports (4x PoE)

PHYSICAL Dimensions (H x W x D) Weight

1.1 x 9.3 x 4.1 in (2.7 x 23.5 x 10.3 cm) 1.7 lbs (2.2 kg)

CERTIFICATION AND WARRANTY Warranty

Lifetime Warranty (2-Year Limited Warranty applies to power supply)

ORDERING INFORMATION

NETWORKING AND CONTROL Networking Connectors

(4) RJ-45 TX/PoE Ports (auto speed-sensing), (1) RJ-45 TX Uplink Port

PHYSICAL Dimensions (H x W x D)

3.8 x 1.5 x 3.5 in (9.7 x 3.8 x 8.9 cm)

Weight

0.7 lbs (0.32 kg)

DIN-Rail Mount

Compatible with TS35/7.5 or TS35/15

Enclosure

IP30

CERTIFICATION AND WARRANTY Warranty

3-Year Limited Warranty

ORDERING INFORMATION

Item Number

31400

Item Number

31401

Manufacturer Part Number

NETGEAR FS108P*

Manufacturer Part Number

N-TRON 105TX-POE

* Refer to the manufacturer website for the latest product updates, product certifications, and complete warranty

** Wiring diagram provided; power cabling not included.

information.

Product Specifications  7


Low-Temperature AC-DC Power Supply PRODUCT OVERVIEW The low-temperature AC-DC power supply is included with Item Number 31401, the N-TRON 105TX-POE Ethernet switch. Additionally, the AC-DC power supply is an optional accessory used to power a single LightRules Network Gateway, when PoE functionality is not desired (for example, if non-PoE switches and electrical service are being used).

1.6 in

4.5 in

-V -V +V +V DC OK

3.6 in

N

L

ENVIRONMENTAL

PHYSICAL

Operating Temperature Range

-40° to 158° F (-40° to 70° C); startup at -31° F (-35°)

Operating Humidity

95% maximum RH (non-condensing)

ELECTRICAL Input Voltage

85 to 264 VAC or 90-375 VDC

Input Frequency

47 to 63 Hz

Power Factor

Meets EN61000-3-2 for class A equipment

Earth Leakage Protection

0.8 mA maximum

Input Protection

Internal fuse T2A, 250 VAC

Output Voltage

48 VDC

Output Current

1.25 A

Dimensions (H x W x D)

3.6 x 1.6 x 4.5 in (9.0 x 4.1 x 11.5 cm)

Weight

0.8 lbs (0.35 kg)

DIN-Rail Mount

Compatible with TS35/7.5 or TS35/15

Recommended Wiring Clearance

Front: 2 in (5.08 cm) Top: 1 in (2.54 cm)

ORDERING INFORMATION Item Number

31500

Manufacturer Part Number

XP Power DNR60US48-JDI001*

* Refer to the manufacturer website for the latest product updates, product certifications, and complete warranty information.

CERTIFICATION AND WARRANTY

Safety

• EN60950-1 UL508 Pollution Degree 2 • UL1310 Class 2 • UL60950-1 Overvoltage Category II • UL508 Overvoltage Category III • DNR30 & DNR60: SEMI F47, ANSI/ISA 12.12.01. Class 1 • Division 2 Groups A,B,C and D

Warranty

3-Year Limited Warranty

www.digitallumens.com 110 Canal St, 7th Floor Boston, MA USA 02114-2014 +1 (617 ) 723-1200

All Rights Reserved © 2011 Digital Lumens Incorporated Subject to change without notice. DOC-000026-00 Rev B 02-11