Gama T LED Parking Lot Lighting

Page 1

Brite Energy Solutions - Tom Knoblock - 1-844-533-2897


LED AREA LIGHT GAMA-T Series FEATURES & BENEFITS

IP65 IK08

TUV SUD Productionmonitored safety tested

E467349

● Preserve the classic shoe box style while utilizing LED latest technology. ● Ideal solution for parking lots, area lighting, car dealerships, and etc. ● Minimum 100μm Corrosion resistant polyester powder coating. Pass 1000h salt spray testing per ASTM B117/ ISO 9227:2012. ● Human centered modular design for easy installation, replacement and maintenance. ● Unmatched thermal management and proven lumen maintenance ratio. ● Improved illumination performance and excellent optics control. ● 15+ light distributions are available for virtually any application. ● Multiple smart lighting control options, e.g. motion sensor, photocell, DALI, 1-10V. ● Standard 5 or 10 years limited warranty are optional.

DIMENSIONAL DRAWING

GAMA-T is highly suitable for carparks and shop fronts where direct lighting is required. A simple yet functional modular design allows for energy efficiency.

W

H

Brite Energy Solutions Tom Knoblock 844-533-2897 Toll Free

L

TECHNICAL PARAMETERS

Black

FLA60-T FLB80-T FLC80-T

FLA30-T FLB40-T

Grey

FLA90-T FLB120-T FLC120-T

Bronze

White

FLA120-T FLB160-T FLC160-T

Power

30- 320W

IP Ra ng

IP65

Input

120-277VAC o r 220-240VAC or 347-480 VAC

SPD

Op onal

PF

>0.95

Cer ficate

UL/ CUL /DLC/ LM79 / CB/CE/ ENEC / ErP/ RoHS / IK08

THD

<20% (120-277VAC)/<10% (220-240VAC)

DALI

Op onal

L85

>60,000H

0-10V

Op onal

Opera ng Temperature

-40℃ ~ +50℃

Photocell

Op onal

Typical Efficacy

100lm/W or 110lm/W or 120lm/W

Smart Control

Op onal

ANSI CCT

3000K/4000K/5000K/5700K

Op c (IESNA)

Type I, Type II, Type III, Type IV, Type V

Min CRI

70* or 80 or 85

Color Op ons

Black/Grey/Bronze/White

* Standard

APPLICATIONS FLA180-T FLB240-T FLC240-T

FLB150-T

FLA210-T FLB280-T FLC280-T

FLA240-T FLB320-T FLC320-T

● Parking, airport ● Auto dealership

1

2

3

● Municipal ● Restaurants ● Retails

USA

43

USA

44


LED AREA LIGHT GAMA-T Series BRIEF SPECIFICATIONS Model No.

System Power

LED Modules

LEDs

EPA

ORDERING INFORMATION Net Weight

Gross Weight

Dimensions (L x W x H)

Carton Dimensions (L x W x H)

300 x 330 x 70(mm)

310 x 425 x 160(mm) 12.21" x 16.73" x 6.3"

3000K

4000K/5000K

Efficacy* (lm/W)

3021 lm

3394 lm

108

Luminous Flux

MODEL (Norminal Power)

OPTIC LENS

MOUNTING

CCT (ANSI)

OPTIONAL COLOR

30K

BK**

00

3045

Black (RAL:9011)

Not required

LIGHTING CONTROL

ACCESSORY INFO

FLA: 120V-277VAC or 220V-240VAC, 30W/module FLA30-T FLA60-T FLBA90-T FLA120-T FLA150-T FLA180-T FLA210-T FLA240-T

31.4W 60.4W 87.0W 111.7W 140.8W 171.9W 201.4W 227.7W

1 2 3 4 5 6 7 8

18 36 54 72 90 108 126 144

0.353sq.ft 0.398sq.ft 0.421sq.ft 0.459sq.ft 0.526sq.ft

5.72Kg(12.61Ibs) 6.31Kg(13.91Ibs) 7.29Kg(16.07Ibs) 7.95Kg(17.53Ibs) 8.65Kg(19.07Ibs)

0.564sq.ft 10.63Kg(23.44Ibs) 0.609sq.ft 11.21Kg(24.71Ibs) 0.654sq.ft 11.78Kg(25.97Ibs)

6.22Kg(13.71Ibs) 7.06Kg(15.56Ibs) 8.17Kg(18.01Ibs) 8.83Kg(19.47Ibs) 9.75Kg(21.49Ibs) 11.66Kg(25.71Ibs) 12.26Kg(27.03Ibs) 12.83Kg(28.29Ibs)

11.81" x 12.99" x 2.76" 14.17" x 12.99" x 2.76" 420 x 330 x 70(mm)

360 x 330 x 70(mm)

370 x 425 x 160(mm) 14.57" x 16.73" x 6.3" 430 x 425 x 160(mm)

16.54" x 12.99" x 2.76"

16.93" x 16.73" x 6.3"

480 x 330 x 70(mm)

490 x 425 x 160(mm)

18.90" x 12.99" x 2.76"

19.29" x 16.73" x 6.3"

540 x 330 x 70(mm) 21.26" x 12.99" x 2.76" 660 x 330 x 70(mm)

550 x 425 x 160(mm) 21.65" x 16.73" x 6.3" 670 x 425 x 160(mm)

25.68" x 12.99" x 2.76"

26.38" x 16.73" x 6.3"

720 x 330 x 70(mm)

730 x 425 x 160(mm)

28.35" x 12.99" x 2.76" 780 x 330 x 70(mm)

28.74" x 16.73" x 6.3" 790 x 425 x 160(mm)

30.71" x 12.99" x 2.76"

31.10" x 16.73" x 6.3"

6143 lm 8884 lm 11906 lm 14838 lm 17949 lm 20875 lm 23721 lm

6902 lm 9982 lm 13377 lm 16672 lm 20168 lm 23455 lm 26653 lm

114 115 120 118 117 116 117

FLA30

FLB40

FLC80

30W

40W

80W

FLA60

FLB80

FLC120

60W

80W

120W

FLA90

FLB120

FLC160

90W

120W

160W

FLA120

FLB160

FLC200

120W

160W

200W

40.3W

1

18

0.353sq.ft

5.72Kg(12.61Ibs)

6.22Kg(13.71Ibs)

FLB80-T

77.0W

2

36

0.398sq.ft

6.31Kg(13.91Ibs)

7.06Kg(15.56Ibs)

FLB120-T

115.4W

3

54

0.421sq.ft

7.29Kg(16.07Ibs)

8.17Kg(18.01Ibs)

FLB160-T

151.6W

4

72

0.459sq.ft

7.95Kg(17.53Ibs)

8.83Kg(19.47Ibs)

FLB200-T

191.7W

5

90

0.526sq.ft

9.67Kg(21.32Ibs)

10.7Kg(23.59Ibs)

FLB240-T

229.0W

6

108

0.564sq.ft 10.63Kg(23.44Ibs)

11.66Kg(25.71Ibs)

FLB280-T

268.3W

7

126

0.609sq.ft 11.21Kg(24.71Ibs)

12.26Kg(27.03Ibs)

FLB320-T

304.9W

8

144

0.654sq.ft 11.78Kg(25.97Ibs)

12.83Kg(28.29Ibs)

300 x 330 x 70(mm) 14.17" x 12.99" x 2.76" 360 x 330 x 70(mm)

310 x 425 x 160(mm) 14.57" x 16.73" x 6.3"

14.17" x 12.99" x 2.76" 420 x 330 x 70(mm)

370 x 425 x 160(mm) 14.57" x 16.73" x 6.3" 430 x 425 x 160(mm)

16.54" x 12.99" x 2.76"

16.93" x 16.73" x 6.3"

480 x 330 x 70(mm)

490 x 425 x 160(mm)

18.90" x 12.99" x 2.76"

19.29" x 16.73" x 6.3"

600 x 330 x 70(mm) 23.62" x 12.99" x 2.76"

24.02" x 16.73" x 6.3"

610 x 425 x 160(mm)

660 x 330 x 70(mm)

670 x 425 x 160(mm)

25.68" x 12.99" x 2.76"

26.38" x 16.73" x 6.3"

720 x 330 x 70(mm) 28.35" x 12.99" x 2.76"

730 x 425 x 160(mm)

780 x 330 x 70(mm)

28.74" x 16.73" x 6.3" 790 x 425 x 160(mm)

30.71" x 12.99" x 2.76"

31.10" x 16.73" x 6.3"

360 x 330 x 70(mm) 14.17" x 12.99" x 2.76" 420 x 330 x 70(mm)

370 x 425 x 160(mm) 14.57" x 16.73" x 6.3" 430 x 425 x 160(mm)

16.54" x 12.99" x 2.76"

16.93" x 16.73" x 6.3"

77.0W

2

36

0.398sq.ft

6.31Kg(13.91Ibs)

7.06Kg(15.56Ibs)

FLC120-T

115.4W

3

54

0.421sq.ft

7.29Kg(16.07Ibs)

8.17Kg(18.01Ibs)

FLC160-T

151.6W

4

72

0.459sq.ft

7.95Kg(17.53Ibs)

8.83Kg(19.47Ibs)

FLC240-T

229.0W

5 6

±175K

T3M

40K**

Type III Medium

3985

T3L

±275K

Type III Long

01 GR Grey (RAL:7004)

03*

Bronze (RAL:8014)

Photocell + Motion Sensor

FLC240

150W

200W

240W

T4S

FLA180

FLB240

FLC280

Type IV Short

5028

180W

240W

280W

T5U

±283K

WH

FLA210

FLB280

FLC320

Average Beam angle 10°

210W

280W

320W

57K

White (RAL:9010)

FLA240

FLB320

240W

320W

T5V Average Beam angle 25°

5665

T5W

±355K

02*

10KA/20KA Surge Protection Device Back Light Shield

Motion Sensor

BZ

FLB200

50K**

Photocell

Safety Cable

04* DALI

05 1-10V dimming

4147 lm

103

T5S Average Beam angle 60°

7262 lm

8160 lm

106

10970 lm

12326 lm

107

14556 lm

16355 lm

108

Average Beam angle 120°

18117 lm

20356 lm

106

Diffuser

21771 lm

24462 lm

107

25506 lm

28658 lm

107

29096 lm

32692 lm

107

T5M Average Beam angle 90°

T5L

T5D

* For FLA & FLB only ** In Stock ● Example 1: FLA30-T-T5S-50K-BK-00 ● Example 2: FLB40-T-T5U-50K-BK-01

FLC80-T

191.7W

T2M Type II Medium

Bird Spike

Average Beam angle 40° 3691 lm

FLB: 347-480VAC, 40W/module

FLC200-T

T1M Type I Medium

FLA150

FLB: 120V-277VAC or 220V-240VAC, 40W/module FLB40-T

T

90 108

0.526sq.ft

9.67Kg(21.32Ibs)

0.564sq.ft 10.63Kg(23.44Ibs)

10.7Kg(23.59Ibs) 11.66Kg(25.71Ibs)

FLC280-T

268.3W

7

126

0.609sq.ft 11.21Kg(24.71Ibs)

12.26Kg(27.03Ibs)

FLC320-T

304.9W

8

144

0.654sq.ft 11.78Kg(25.97Ibs)

12.83Kg(28.29Ibs)

480 x 330 x 70(mm)

490 x 425 x 160(mm)

18.90" x 12.99" x 2.76"

19.29" x 16.73" x 6.3"

600 x 330 x 70(mm) 23.62" x 12.99" x 2.76"

610 x 425 x 160(mm) 24.02" x 16.73" x 6.3"

660 x 330 x 70(mm)

670 x 425 x 160(mm)

25.68" x 12.99" x 2.76"

26.38" x 16.73" x 6.3"

720 x 330 x 70(mm) 28.35" x 12.99" x 2.76"

730 x 425 x 160(mm)

780 x 330 x 70(mm)

28.74" x 16.73" x 6.3" 790 x 425 x 160(mm)

30.71" x 12.99" x 2.76"

31.10" x 16.73" x 6.3"

7262 lm

8160 lm

106

10970 lm

12326 lm

107

14556 lm

16355 lm

108

18117 lm

20356 lm

106

21771 lm

24462 lm

107

25506 lm

20356 lm

107

29096 lm

24462 lm

107

● Example 2: FLC80-T-T5U-50K-BK-03

*CCT 4000K/5000K/5700K

46


Light Module ——LED Optical Engine



ARRLUX

GAMA Series LED Area Light

Huizhou Arrlux Optoelectronic Co.,Ltd

INSTALLATION INFORMATION

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION W

IMPORTANT INSTALLATION INFORMATION

W

1.Before commencing installa on or maintenance, ensure electricity is switched off at the mains. Installa on or maintenance should be carried out by a qualified electrician. L

2.The luminaire must not, under any circumstances, be installed directly to flammable materials, and luminaires must not be covered with any flammable materials. 3.Moun ng height range of 6 to 12 meters, this model is suitable for outdoor ligh ng. 4.Ensure there is adequate free air circula on of at least 50cm around the luminaire. All luminaires run hot. It is the installer's responsibility to consider fire risk and take appropriate precau ons.

Main specifica ons: Model No.

No. of LEDs

System Wa age

Dimensions (L x W x H)

Net Weight

EPA*

FLB80-T

36

80W

360(14.17")x330(12.99")x70mm(12.76")

5.88kg(12.94lbs.)

0.034m²

FLB120-T

54

120W

420(16.53")x330(12.99")x70mm(12.76")

6.87kg(15.11lbs.)

0.037m²

FLB160-T

72

160W

480(18.90")x330(12.99")x70mm(12.76")

8.38kg(18.44lbs.)

0.041m²

FLB200-T

90

200W

600(23.61")x330(12.99")x70mm(12.76")

9.25kg(20.35lbs.)

0.048m²

FLB240-T

108

240W

660(26.00")x330(12.99")x70mm(12.76")

10.21kg(22.46lbs.)

0.052m²

Working Environment

IP

- 40℃-+50℃

IP65

Working Environment

IP

- 40℃-+50℃

IP65

Input Voltage:120-277V~50/60Hz The ingress protec on of the fixture is IP65 if the mains supply cable's specifica on is H07RN-F 3*1.5m㎡.

Model No.

No. of LEDs

System Wa age

Dimensions (L x W x H)

Net Weight

EPA*

FLC80-T

36

80W

360(14.17")x330(12.99")x70mm(12.76")

5.88kg(12.94lbs.)

0.034m²

FLC120-T

54

120W

420(16.53")x330(12.99")x70mm(12.76")

6.87kg(15.11lbs.)

0.037m²

FLC160-T

72

160W

480(18.90")x330(12.99")x70mm(12.76")

8.38kg(18.44lbs.)

0.041m²

FLC200-T

90

200W

600(23.61")x330(12.99")x70mm(12.76")

9.25kg(20.35lbs.)

0.048m²

FLC240-T

108

240W

660(26.00")x330(12.99")x70mm(12.76")

10.21kg(22.46lbs.)

0.052m²

Input Voltage:347-480V~50/60Hz The ingress protec on of the fixture is IP65 if the mains supply cable's specifica on is H07RN-F 3*1.5m㎡.


LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

Installa on Instruc on & Installa on Steps Installa on and Moun ng A

1

Installa on and Moun ng A

2 Moun ng arm

Moun ng arm

Pole Pole

Spring washer(M10)

Spring washer(M10)

STEP 1: 1.Loosen the M12 screws, nuts, spring washers on the moun ng arm with a wrench. 2.Insert the pole into the middle hole of moun ng arm ll to the end. See Figure 1.

STEP 2: When the pole is inside the moun ng arm, adjust the moun ng angle of the lamp, then screw the the M12 screws, nuts and spring washers. See Figure 2

Installa on and Moun ng B

3

M10 screw M6 screw

Pole

Installa on and Moun ng B

4

Moun ng plate

STEP 3: 1. Fix the moun ng plate on the pole with M10 screws. 2. Connect the cables from the luminaire and from the pole. Please See figure 3 the wiring diagram.

STEP 4: 1. Fix the luminaire to the moun ng plate with 4 M6*20 screws. See Figure 4

Installa on and Moun ng C

5

Installa on and Moun ng C

6 M10 screw M6 screw

Moun ng plate Wall

Wall

STEP 5: 1. Fix the moun ng plate on the wall with M10 screws. 2. Connect the cables from the luminaire and from the wall. Please See figure 5 the wiring diagram.

STEP 6: 1. Fix the luminaire to the moun ng plate with 4 M6*20 screws. See Figure 6

Safety No ce

Alterna ng Current

WIRING INSTRUCTION ***IF THERE IS JUNCTION BOX IN CEILING: STEP I: Connect the LINE wire in the mains power supply cord to black LINE wire from lightbody . STEP II: Connect the NEUTRAL wire in the mains power supply cord to white NEUTRAL wire from lightbody . STEP III: Connect the green grounding wire in the mains power supply cord to green grounding wire from lightbody .

Input wire H07RN-F 3x1.5mm² (SJOW 3 * 18AWG) or rubber sheathed cable (not supplied).Conductor must have a minimum cross-sec onal area of 1.0mm² (18AWG).

Electrical Connec ons

7

Terminal Block

L

LIVE - Black

GROUND

G

GROUND-Housing

NEGATIVE

N

NEGATIVE - White

LED DrivER

Mains power supply

LIVE

STEP 7: Reference “Electrical Connec ons” sec on for comple ng electrical connec ons. See Figure 7

This logo indicates that this product must not be disposed of with other waste. Please recycle used lamps to prevent environmental hazard and threats to human health resul ng from improper disposal.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.