5 minute read
VistaVox S Ceph: 3-in-1 X-ray system from Dürr Dental.
Short scan time and high image quality with a low X-ray dose
Reduced radiation dose thanks to the anatomically adapted volume
Excellent image quality in 2D and 3D thanks to the high-resolution CsI sensor with a pixel size of 49.5 μm
Easy, intuitive workflow
Jaw-shaped field of view
Ideal 3D imaging volume matched to the shape of the jaw (Ø 130 x 85 mm)
Website
Any questions? Please contact: Dürr Dental Middle East, Phone: +968 7194 6652, Mail: middle.east@duerrdental.com
Ø 50 x 50 mm volumes in up to 80 μm resolution
The patient presented to the clinic every 6 weeks for chain replacement because slow intrusion is needed. The 2nd molar was blocked below the distal contact area of the 1st molar, monitored IPR was carried out between the 1st and 2nd molar on both sides to facilitate the intrusive movement. The treatment took 10 months with 7 appointments.
Retention protocol:
Case Discussion
The success of maxillary molar intrusion depend on the stability of the miniscrews placed at the appropriate level on the buccal and palatal side to achieve pure intrusive movements. Forces and appointments intervals needed to be adjusted without over loading the teeth or the miniscrews. Nickel Titanium coil springs could have been used for more constant forces acting on the molars but could pose a problem from hygiene and comfort standpoint, for those reasons , pre-stretched elastomeric chains were applied.
Conclusion:
Molar protrusion and molar protraction, once regarded as among the most difficult tooth movements to achieve are now successfully performed with the use of orthodontic TADs.
- After 7 months of active intrusion, the level of the 2nd molars was found appropriate, but the intrusion force was maintained as a means of retention for 2 more months.
- During that time, the patient placed 2 implants in the lower posterior edentulous areas (1 on each side)
- Debonding was done, and a thermoformed plastic retainer was manufactured and worn by the patient at all times except at meals to act as retention until the final crowns are placed on the implants which will then prevent relapse of the upper 2nd molars .
- The patient was offered the treatment of the cross-bite on the 1st molars with a segmental fixed appliance, but he declined
Bibliography
1. Creekmore TD, Eklund MK. The possibility of skeletal anchorage. J Clin Orthod. 1983 Apr;17(4):266-9. PMID: 6574142.
2. Kanomi, R. (1997). Mini-implant for orthodontic anchorage. Journal of clinical orthodontics, 31(11):763-767.
3. Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg. 1998;13(3):201-9. PMID: 9835819.
4. Hyo-Sang, Park. (1999). The skeletal cortical anchorage using titanium microscrew implants. Korean Journal of Orthodontics, 29(6):699-706.
5. Maino BG, Bednar J, Pagin P, Mura P. The spider screw for skeletal anchorage. J Clin Orthod. 2003 Feb;37(2):90-7. PMID: 12674749.
6. Yamaguchi M, Inami T, Ito K, Kasai K, Tanimoto Y. Miniimplants in the anchorage armamentarium: new paradigms in the orthodontics. Int J Biomater. 2012;2012:394121. doi: 10.1155/2012/394121. Epub 2012 Jun 5. PMID: 22719763; PMCID: PMC3374939.
7. Bae SM, Park HS, Kyung HM, Kwon OW, Sung JH. Clinical application of micro-implant anchorage. J Clin Orthod. 2002 May;36(5):298-302. PMID: 12056211
8. Jae-Hyun Sung, H.-M. K.-M.-S.-W. (2006). Microimplamts in Orthodontics . Daegu: Dentos .
Light-curing Glass Ionomer Filling Material
• Excellent working time and the setting time is individually adjustable by light-curing
• Immediately packable after placement in the cavity
• No varnish required- fill, polymerise and finish
• No need to condition the dental hard tissue
• Does not stick to the instrument and is easy to model
• Suitable for large cavities
Are you interested in our entire product range and detailed product information?
Visit our website or contact us directly!
PROMEDICA
Dental Material GmbH
CA® Pro:
Ultradent Products Introduces new Gemini EVO ™ Laser: Next Evolution in Laser Dentistry
The new standard in aligner treatment
Products, Inc., a leading developer and manufacturer of high-tech dental is introducing the latest addition in the Gemini™ laser family, the Gemini EVO™ EVO™ laser provides 100 watts of peak power—5x the power of the original laser for faster cutting, less heat, and ultra-clean incisions in soft tissue. Useroperation is facilitated through a guided touch interface and multiple preset are divided into three categories for efficient, intuitive use. Wi-Fi connectivity over-the-air updates with dedicated tech support—there’s also a mobile app dashboard to monitor usage statistics, including ROI.
Ultradent Products Introduces new Gemini EVOTM Laser: The Next Evolution in Laser Dentistry
Ultradent Products Introduces new Gemini EVOTM Laser: The Next Evolution in Laser Dentistry
Ultradent Products, Inc., a leading developer and manufacturer of high-tech dental materials, is introducing the latest addition in the GeminiTM laser family, the Gemini EVOTM diode laser.
Innovative double shell construction.
References
adapters are included with the Gemini EVO™ laser (3 mm, 7 mm, and 25 mm) clinicians can take full advantage of laser technology in their office it also features a warranty (which can be extended), has three wavelength modes, and uses the as the original Gemini™ laser. information about Gemini EVO™ please contact sophia.yadi@ultradent.com
CA® Pro
High elasticity and break resistance thanks to the double shell construction with flexible elastomer core.
Ultradent Products Introduces new Gemini EVOTM Laser: The Next Evolution in Laser Dentistry
Ultradent Products, Inc., a leading developer and manufacturer of high-tech dental materials, is introducing the latest addition in the GeminiTM laser family, the Gemini EVOTM diode laser.
The Gemini EVOTM laser provides 100 watts of peak power—5x the power of the original Gemini laser—for faster cutting, less heat, and ultra-clean incisions in soft tissue. User-friendly operation is facilitated through a guided touch interface and multiple preset procedures are divided into three categories for efficient, intuitive use. Wi-Fi connectivity allows for over-the-air updates with dedicated tech support—there’s also a mobile app and dashboard to monitor usage statistics, including ROI.
Magne P, Silva M, Oderich E, Boff LL, Enciso R. Damping behavior of implantsupported restorations. Clinical Oral Implants Research. 2013;24(2):143–8.
The Gemini EVOTM laser provides 100 watts of peak power— 5x the power of the original
Liebig J. Energy Dissipation and Damping Behavior of Commonly Used CAD / CAM Materials. 2018;35392.
Three PBM adapters are included with the Gemini EVOTM laser (3 mm, 7 mm, and 25 mm) so clinicians can take full advantage of laser technology in their office—it also features a two-year warranty (which can be extended), has three wavelength modes, and uses the same tips as the original GeminiTM laser.
3. Reymus M, Roos M, Eichberger M, Edelhoff D, Hickel R, Stawarczyk B. Bonding to new CAD/CAM resin composites: influence of air abrasion and conditioning agents as pretreat-ment strategy. Clinical Oral Investigations. 2019;23(2):529–38.
4. Emsermann I, Eggmann F, Krastl G, Weiger R, Amato J. Influence of Pretreatment Methods on the Adhesion of Composite and Polymer Infiltrated Ceramic CAD-CAM Blocks. The journal of adhesive dentistry. 2019;21(5):1–11.
For more information about Gemini EVOTM please contact sophia.yadi@ultradent.com
About Ultradent Products, Inc.
5. Kaleli N, Sarac D, Külünk S, Öztürk Ö. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study. Journal of Prosthetic Dentistry [Internet]. 2017;1–9. Available from: http:// dx.doi.org/10.1016/j. prosdent.2017.03.008 constant force level less initial force
Gemini laser—for faster cutting, less heat, and ultra-clean incisions in soft tissue. Userfriendly operation is facilitated through a guided touch interface and multiple preset procedures are divided into three categories for efficient, intuitive use. Wi-Fi connectivity allows for over-the-air updates with dedicated tech support—there’s also a mobile app and dashboard to monitor usage statistics, including ROI.
Three PBM adapters are included with the Gemini EVOTM laser (3 mm, 7 mm, and 25 mm) so clinicians can take full advantage of laser technology in their office—it also features a two-year warranty (which can be extended), has three wavelength modes, and uses the same tips as the original Gemini
Contact
continuous force transmisson high wearing comfort
Products, Inc., is a leading developer and manufacturer of high devices, and instruments worldwide. Ultradent’s vision is to improve oral globally. Ultradent also works to improve the quality of life and health of individuals through financial and charitable programs.
For more information about Gemini EVO please contact sophia.yadi@ultradent.com