230V Network-Grade PDU Brochure English (95-3104)

Page 1

U ni t s

P o w er

U ni t s D is t ri b u t ion P o w er U ni t s D is t ri b u t ion P o w er

D is t ri b u t ion

U ni t s

230V Network-Grade PDUs (Power Distribution Units) Reliable rackmount power distribution for high-density, high-availability IT environments 8 - 38 Outlets With or Without Load Meter With or Without Network Interface With or Without Remote Outlet Control

P o w er

D is t ri b u t ion

Power Distribution Units

1U or 0U (Vertical) Rackmount Installation

Reliable Power Distribution

Load Meter

Tripp Lite network-grade PDUs distribute power from a UPS system, generator or wall outlet to multiple devices, including critical servers, storage and network/ telecom equipment. There are four distinct PDU types: Basic, Metered, Monitored and Switched. Refer to the chart below to understand the features and benefits associated with each type.

Metered, Monitored and Switched PDUs display the connected equipment load (current draw) in amps.

Network Interface

PDU Types Basic Metered Monitored Switched PDUs PDUs PDUs PDUs

Feature

Benefit

Multiple Outlets

Provide reliable power distribution from a UPS system, generator or utility source to multiple devices.

C14 or C20 Inlet

Connects to a detachable input power cord (user-supplied) with a region-specific plug.

Select Models

High-Current Input and Low-Current Outlets

Convert a single highamperage outlet into multiple low-amperage outlets to power multiple devices.

Select Models

Load Meter

Displays connected equipment load (current draw) in amps to safely optimize load levels and prevent overloads.

Network Interface

Provides remote monitoring and alerts to prevent overloads that cause downtime. Supports centralized management via included PowerAlert NMS or a third-party network management system.

Remote Individual Outlet Control

Eliminates costly service calls by rebooting locked devices from any location. Increases runtime of critical systems by turning off nonessential loads automatically during power failures.

Load Meter

Monitored and Switched PDUs support remote monitoring, alerts and centralized management via SNMP, Web or telnet.

Monitored and/or Switched PDUs

TCP/IP

Remote Workstation with PowerAlert Network Management System (See page 4 for additional information about PowerAlert.)

Remote Outlet Control Switched PDUs allow remote control of individual outlets for remote rebooting, load shedding and more.


Feature FOCUS B E

A

I

D

PDUMH15HVNET

E

C

Similar Model: PDUMH20HVNET (20A Version)

A

A

Also includes: H

A

E

C

A

I

E

C B

C

F

A PDU12IEC (front and back)

Similar Model: PDUNV (Includes Fixed Input Cord Terminating with C20 Inlet and Adapters Terminating with C14, 5-15P, 5-20P, L5-20P and L6-20P)

E A

I

D

C

K

E

A

A

A

B

B

PDUMH20HVATNET (front and back)

Also includes: H

D

D

B

B J

F

PDUMV20HVNET

PDUMV20HV

PDUMV32HVNET

Also includes:

Also includes:

Also includes:

E G H

E G H

Similar Model: PDUMNV20HV (Without Remote Outlet Control)

Plug and Outlet Identification

I PLUG

I

E

G

OUTLET

I

H 2

C14

C20

32A Blue IEC 60309 2P+E 6H-P

C13

C19

32A Blue IEC 60309 2P+E 6H-R

32A Blue IEC 60309 2P+E 6H-P 32A Blue IEC 60309 2P+E 6H-P

32A Blue IEC 60309 2P+E 6H-R 32A Blue IEC 60309 2P+E 6H-R


A AC Outlets

G Toolless Mounting Buttons

Distribute power to multiple devices.

Provide quick and easy toolless 0U (vertical) rackmount installation in compatible rack enclosures and open frame racks. Detachable 90° rotation brackets allow PDU outlets to face the rear of the rack enclosure for improved access and airflow.

B AC Inlet (C14 or C20) Connects to a user-supplied input power cord with a region-specific plug.

Switched Outlet

C Load Meter Displays the connected equipment load (current draw) in amps. Load Meter

D Network Interface

Enables remote monitoring over the local network or Internet via SNMP, Web browser or telnet. Supports load threshold and power status alerts. Supports centralized management via included PowerAlert NMS software (see page 4) or a third-party network management system. Monitors temperature and humidity through optional ENVIROSENSE accessory. Switched PDUs also support remote individual outlet control for remote reboots, automatic load shedding and more.

Toolless Mounting Button

H Removable Cord Retention Brackets Secure and organize power cords, reducing the risk of accidental disconnection.

Cord Retention Bracket

I Metal Housing Maximizes durability and safety. Network Interface

J Splash-Proof Plug 32A Blue IEC 60309 2P+E 6H-P plug with IP 44 protection rating connects to a compatible outlet. Splash-Proof Plug

K Automatic Transfer Switch (ATS)

Provides input power redundancy. The PDU includes primary and secondary AC inputs. The PDU automatically switches to the secondary input if the primary input’s voltage or frequency deviates from the designated safe operating range. Two front panel LEDs marked “primary” and “secondary” indicate the active input source. The ATS function can be used to provide redundant power to single-cord devices or to make any on-line UPS system hotswappable. Note: If the primary input is plugged into a UPS system, it must be an on-line UPS system.

ENVIROSENSE

E Removable Mounting Brackets Support rackmount installation and surface mounting.

F Circuit Breakers Protect against short circuits and overloads.

Specifications

Model

Input/Output Voltage (50/60 Hz)

Maximum Input Current (A)

Metered Output Banks (B)

AC InPUT Connector (C)

Outlets

Rack Size  (I)

(Quantity & type)

Switched PDUs (Network-Grade Power Distribution, Load Meters, Network Interface and Remote Outlet Control) PDUMH15HVNET

200-250V

15A

1

C14 inlet (D)

8 (C13)

1U

PDUMH20HVNET

200-250V

20A

1

C20 inlet (E)

8 (C13)

1U

PDUMH20HVATNET

200-250V

20A

1

2 x C20 inlet (F)

10 (8 C13 + 2 C19)

1U

PDUMV20HVNET

200-250V

20A

1

C20 inlet (G)

24 (20 C13 + 4 C19)

0U (163 cm long) (J, K)

PDUMV32HVNET

200-250V

32A

2

32A Blue IEC 60309 2P+E 6H-P plug (H)

24 (20 C13 + 4 C19)

0U (178 cm long) (J, K)

Monitored PDU (Network-Grade Power Distribution, Load Meters and Network Interface) PDUMNV20HV

200-250V

20A

1

C20 inlet (F)

24 (20 C13 + 4 C19)

0U (162 cm long) (J, K)

1

C20 inlet (F)

38 (32 C13 + 6 C19)

0U (162 cm long) (J, K)

Metered PDU (Network-Grade Power Distribution and Load Meters) PDUMV20HV

200-250V

20A

Basic PDUs (Network-Grade Power Distribution) PDU12IEC

100-250V

16A

C20 inlet

14 (12 C13 + 2 C19)

1U or 0U (44 cm long) (J)

PDUNV

100-250V

16A

C20 inlet

14 (12 C13 + 2 C19)

1U or 0U (44 cm long) (J)

(G)

(A) Agency-derated input is 16A for 20A units, 12A for 15A units @ 208V and 10A for 15A units @ 230V. (B) Metered, Monitored and Switched PDUs can display the PDU current for all outlets combined. PDUMV32HVNET can also display the current for each output bank. (C) Connect each inlet to a user-supplied input power cord with a region-specific plug. Connect each plug to a compatible outlet. (D) Includes detachable 198 cm input cord with C14 inlet. (E) Includes detachable 259 cm input cord with C20 inlet, plus adapter for L6-20P plug. (F) Includes primary and secondary AC inputs. The PDU automatically switches to the secondary input if the primary input’s voltage or frequency deviates from the designated safe operating range. (G) Includes detachable 300 cm input cord with L6‑20P plug. (H) Splash-proof plug (IP 44 protection rating). (I) PDUs also support surface mounting. (J) 0U represents vertical rack installation. (K) PDU includes mounting buttons for toolless installation in compatible racks. Detachable 90° rotation brackets allow PDU outlets to face the rear of the rack for improved access and airflow.

3


Centralized Power Management with PowerAlert NMS PowerAlert NMS (Network Management System) software is included with Monitored and Switched PDUs, allowing IT managers to access all PDU functions from any location. PowerAlert NMS can auto-discover and manage up to 250 Monitored or Switched PDUs and associated environmental sensors (model ENVIROSENSE, sold separately) over the network from a single interface. • Monitor PDUs remotely, including load levels, other power conditions, environmental conditions and more. Receive alerts via e-mail, textmessaging or SNMP if values exceed user-defined alarm thresholds. • Mass-configure PDUs with pre-defined settings or firmware updates. • Log power events and data according to user-defined parameters. • Reboot unresponsive devices from any distance, reducing the need for expensive and time-consuming trips to remote sites. (Switched PDUs) • Shed nonessential loads automatically during power failures to increase the runtime of critical systems. (Switched PDUs) • Prevent unauthorized loads by locking out unused outlets. (Switched PDUs) • Schedule equipment idling to reduce power costs by turning off selected devices during off-hours. (Switched PDUs)

PowerAlert Network Management System

Power Cords & Accessories Model

Plug

Outlet

Length

Rating

Description

P004-002-5

C14

C13

0,6 m

10A / 100-250V

Cord (5-Pack)

P005-002

C14

C13

0,6 m

15A / 100-250V

Cord

P005-006

C14

C13

1,8 m

15A / 100-250V

Cord

P005-010

C14

C13

3m

15A / 100-250V

Cord

P047-002

C14

C19

0,6 m

15A / 100-250V

Cord

P047-004

C14

C19

1,2 m

15A / 100-250V

Cord

P047-006

C14

C19

1,8 m

15A / 100-250V

Cord

P047-010

C14

C19

3m

15A / 100-250V

Cord

P036-002

C20

C19

0,6 m

20A / 100-250V

Cord

P036-006

C20

C19

1,8 m

20A / 100-250V

Cord

P032-007

C20

C13

2,1 m

20A / 100-250V

Cord

P056-006

BS1363

C13

1,8 m

13A / 200-250V

Cord

P052-008

BS1363

C19

2,4 m

13A / 200-250V

Cord

P054-006

CEE 7/7

C13

1,8 m

16A / 200-250V

Cord

P050-008

CEE 7/7

C19

2,4 m

16A / 200-250V

Cord

C14

Wonpro*

2,5 cm

10A / 100-250V

Adapter

UNIPLUGINT

* The Wonpro universal outlet is compatible with most household plugs worldwide. Model

Description

ENVIROSENSE

Remote environmental sensor for Monitored and Switched PDUs. Monitors ambient temperature and humidity. Also monitors and controls alarm, security and telecom devices through contact closure communications. Can monitor up to three additional environmental sensors. Connects to optional SRSWITCH magnetic switch kit for rack enclosure door entry detection.

SRSWITCH

Magnetic switch kit. Includes two entry detection switches for rack enclosure doors. Requires ENVIROSENSE.

P350-10N-10

10-pack of reusable black hook-and-loop cable ties. 25 cm x 1,6 cm.

PDUMVROTATEBRKT

Allows vertical PDU outlets to face rear of rack for improved airflow. (Included with vertical Monitored and Switched PDUs.)

About Tripp Lite Since 1922, Tripp Lite has established a global reputation for quality manufacturing, superior value and excellent service. Tripp Lite makes more than 1000 products to power, protect and connect electronic equipment, including UPS systems,

Tripp Lite World Headquarters

replacement batteries, PDUs, rack systems, surge

1111 W. 35th Street, Chicago, IL 60609 USA • +1.773.869.1212 • www.tripplite.com

suppressors, console servers, KVM switches,

Tripp Lite América Latina (Miami): +1.305.406.2523 • info_la@tripplite.com

cables, laptop accessories, power strips and

Tripp Lite Middle East (Dubai): +971.4.887.1633 • salesint@tripplite.com

inverters. Learn more at www.tripplite.com.

Tripp Lite Russia (Moscow): +7.495.799.5607 • inforu@tripplite.com Tripp Lite United Kingdom: +44.12.7651.6838 • salesint@tripplite.com

Copyright © 2010 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ from final products.

4

200910068 95-3104


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.