230V SmartOnline 3-Phase UPS System Brochure English (95-2917)

Page 1

SmartOnline 3-Phase UPS Systems ™

• 220/380 , 230/400 or 240/415 VAC

The Most Reliable and Cost-Effective Power Solutions for Your Data Center

SUPPORT UP TO 320 KVA IN PARALLEL

SmartOnline E3 Series (20 - 80 kVA) Ideal Output Power PROTECTS CRITICAL SYSTEMS MODULAR aRCHITECTURE ELIMINATES DOWNTIME 1-to-1 GENERATOR SiZING Lowers Installation Costs Extreme Efficiency Lowers Operating Costs

SmartOnline T3 Series (30 kVA) reliable OPERATION keeps equipment POWERED versatile battery system EXPANDS runtime OPTIONS


SMartONlINe e3 SerIeS UPs systems Extremely efficient protection for your most important equipment Ideal Output pOwer PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated, pure sine wave output, isolating your critical systems from damaging and disruptive power problems.

MOdular arCHIteCture ELIMINATES DOWNTIME Internal N+1 power module redundancy, parallel capability (up to four units) and fault-tolerant bypass features keep your critical systems highly available and productive around the clock.

1-tO-1 GeNeratOr SIZING LOWERS INSTALLATION COSTS An advanced IGBT rectifier produces best-in-class <4% THDi (input Total Harmonic Distortion), eliminating costly over-sizing requirements for generators, breakers and cables.

extreMe effICIeNCy LOWERS OPERATINg COSTS Efficiency up to 97% significantly lowers power and cooling costs compared to multiple smaller units or legacy high-capacity units.

C

O

N

t

e

N

t

S

Ideal OuTpuT pOwER MOdular ARCHITECTuRE parallel FEATuREs 1-tO-1 GENERATOR sIZING extreMe EFFICIENCY GreeN pOwER MONItOrING AND CONtrOl battery CABINETs COMpaCt FOOTpRINT OrderING INFORmATION teCHNICal spECIFICATIONs

SMartONlINe e3 SerIeS upS SySteMS Su80kX 80 kVA / 64 kW Su60kX 60 kVA / 48 kW Su40kX 40 kVA / 32 kW Su20kX 20 kVA / 16 kW

3 3 3 4 4 4 5 5 6 6 7

SMartONlINe t3 SerIeS UPs systems Reliable protection for small and mid-range installations relIable OperatION kEEPS EquIPMENT POWERED On-line operation and fault-tolerant bypass features keep your equipment powered at all times.

verSatIle battery SySteM EXPANDS RuNTIME OPTIONS A hot-swappable battery system with convenient front-panel access allows you to customize battery backup runtime.

C

O

N

SMartONlINe t3 SerIeS upS SySteMS Su30k3/3INT 30 kVA / 24 kW 2

t

e

N

t

teCHNICal spECIFICATIONs relIable OpERATION verSatIle BATTERY sYsTEm OrderING INFORmATION

S 7 8 8 8


SmartOnline E3 Series UPS Systems Ideal Output Power SmartOnline E3 Series UPS Systems isolate your critical equipment from power problems, including surges, line noise, harmonic distortion, electrical impulses, frequency variations, brownouts, overvoltages and blackouts. True on-line operation continually transforms AC input power into filtered DC power, then resynthesizes it into precisionregulated AC output with a pure sine wave. Strong overload capacity supports up to 150% output for up to 60 seconds. Reliable backup power with zero transfer time to battery keeps equipment operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. Rapid recharging restores battery charge levels in as little as two hours.

MODULAR ARCHITECTURE

MODULAR DESIGN ARCHITECTURE INTERNAL N+1 REDUNDANCY PARALLEL FOR N+1 REDUNDANCY

20 kVA

20 kVA

Redundancy

Power Module

20 kVA

Power Module

60 240kVA kVA

20 kVA

Power Module

Load Load

20 kVA

Power Module

80 kVA UPS System

80 kVA UPS System

External Battery Cabinet

80 kVA UPS System

80 kVA UPS System

80 kVA UPS System

Intelligent, independent 20 kVA power modules provide internal redundancy. When the UPS is configured for N+1 redundancy, convenient hot-swap power modules can be replaced without powering down the connected load. In the event of a power module fault, the load is automatically distributed among the remaining modules. Because load redistribution happens without interrupting critical systems, mean time to recovery is zero—far superior to legacy UPS systems. In addition, redundant control circuits eliminate a single point of failure commonly found in less-reliable UPS designs. Dual input connections provide an additional level of redundancy by allowing each UPS system to be powered by two separate utility sources.

In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system. For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less.

If service or repair requires UPS shutdown, all models include a manual bypass breaker and automatic bypass function that maintain system availability by passing through AC power until the UPS system returns to service.

Four 80 kVA SmartOnline E3 Series UPS Systems can provide redundant backup power for a 240 kVA load.

PARALLEL FOR N+1 REDUNDANCY

240 kVA Load

80 kVA UPS System

80 kVA UPS System

80 kVA UPS System

80 kVA UPS System

PARALLEL TO MAXIMIZE CAPACITY

Parallel Features Increase fault tolerance or quadruple output capacity by connecting up to four SmartOnline E3 Series UPS Systems in parallel. If one UPS system is taken offline for maintenance, the other UPS systems automatically compensate to support the equipment load—without requiring additional programming. SmartOnline E3 Series UPS Systems ship ready for parallel operation. Patented dual-DSP technology provides optimal synchronization of power sources.

320 kVA Load

80 kVA UPS System

80 kVA UPS System

80 kVA UPS System

80 kVA UPS System

Four 80 kVA SmartOnline E3 Series UPS Systems can provide backup power for a 320 kVA load.

3


1-TO-1 Generator SIZING

Extreme EFFICIENCY

SmartOnline E3 Series UPS Systems have

superior operating efficiency at all load levels—up to 97% in economy mode. Increasing

a generator-friendly design that decreases

efficiency lowers UPS system operating costs by reducing electricity consumption, heat

installation costs. A high input power

emissions and cooling costs. Replacing 160 kVA of legacy UPS capacity with SmartOnline

factor and IGBT rectifier with DSP control

E3 UPS Systems can save more than US$20 000 per year.

create less than 4% input Total Harmonic Distortion (THDi). Low THDi enables costsaving 1-to-1 sizing of UPS systems to generators, allows generators to run cooler and extends the operational lifespan of all

Advanced high-utilization IGBT inverter technology and high-speed DSP control provide

In addition, SmartOnline E3 Series UPS Systems automatically correct the widest range of incoming voltages in their class. The wide voltage window and temperature-compensated charging combine to decrease battery wear significantly, extending service life and reducing replacement costs.

input components. Low THDi also reduces sizing requirements for cables and breakers and improves reliability by eliminating

EFFICIENCY CHART 100%

nuisance breaker tripping and overheated transformers.

Generators Cabling Breakers

SmartOnline E3 Series Extreme Efficiency Advantage

SmartOnline E3 EFFICIENCY

SmartOnline E3

INSTALLATION COST COMPARISON

85%

Related Costs

Legacy UPS

Legacy UPS 70% 50%

75%

100% LOAD

Cost

The extreme efficiency of SmartOnline E3 Series UPS Systems can reduce your data center’s power costs significantly. Replacing 160 kVA of legacy capacity can save more than US$20 000 per year.

SmartOnline E3 Series UPS Systems reduce installation costs up to 30% versus legacy UPS systems.

Green POWER Efficient

SmartOnline

CUMULATIVE ENVIRONMENTAL IMPACT OVER FIVE YEARS

E3

Legacy UPS Energy Usage (MWh)

1 956

Series UPS Systems save

1

energy and reduce your

1 752

SmartOnline E3 Energy Usage (MWh)

1 188 1 065

Legacy UPS CO2 Emissions (Metric Tons)

carbon footprint. Replacing 160 kVA

of

legacy

SmartOnline E3 CO2 Emissions (Metric Tons)

UPS

3 911

capacity can reduce CO2 emissions by

3 504

2

2 378

123 metric tons and save more than 200

2 130

megawatt-hours* of electricity per year— 5 867

enough to power 16 single-family homes.

5 256

3

3 566

An extremely wide voltage correction

3 195

range reduces battery wear up to 40%, so batteries last longer. Batteries are also recyclable and contain a high percentage

7 823 7 008

4

4 755 4 259

of recycled materials, creating an efficient manufacturing

loop

that

conserves 9779

resources and reduces landfill waste.

8 760

5

5 944

Tripp Lite also restricts hazardous

5 324

substances during manufacture, maintaining industry leadership in RoHS compliance. * 1 megawatt-hour = 3,6 gigajoules.

Replacing 160 kVA of legacy UPS capacity with SmartOnline E3 Series UPS Systems can save 200 megawatt-hours* and reduce CO2 emissions by 123 metric tons (enough to offset 2 000+ flights from London to Paris) per year.

4


MONItOrING AND CONtrOl

POWERALERT NETWORK MANAGEMENT SYSTEM

Convenient communication and management features

allow

you

to

monitor

power

conditions, receive automatic alerts and control smartOnline E3 series ups systems with drift-proof digital precision from any distance. • ContaCt CLoSURE IntERfaCE Connects to an Emergency power Off (EpO) circuit for emergency ups system shutdown. Also allows the ups system to monitor external battery cabinets and communicate

Real-Time Power Status Consoles

operational messages.

PowerAlert allows you to manage up to 250 UPS systems from a single workstation.

• RS-232 SERIaL PoRt Connects to a server for shutdown commands and reporting through powerAlert software (included). • aCCESSoRy CaRd SLot Optional network card (sNmpwEBCARD) provides remote monitoring and control. Optional environmental sensor (ENVIROsENsE) monitors

The LED/LCD control panel provides detailed UPS status information.

temperature, humidity and more. • nEtwoRk PowER ManagEMEnt

Contact Closure Interface

You can manage ups systems with powerAlert Network management system (included) or a third-party

Accessory Card slot

network management system. • LEd/LCd ContRoL PanEL Offers convenient push button control and communicates operational modes, conditions and warnings.

parallel Interface

Rs-232 serial port The rear panel includes several communication interfaces.

battery CAbINETS All smartOnline E3 series ups systems can connect to external battery cabinets: • Models SU20KX and SU40KX include internal batteries and do not require external battery cabinets, but external battery cabinets can be added to expand runtime. Model SU20KX also has room to add two additional suRBC2030 internal battery packs. • Models SU60KX and SU80KX do not have internal batteries and require an external battery cabinet. Additional battery cabinets can be connected to expand runtime. External battery cabinets are available in a variety of capacities. models BP480V26B and BP480V40C support temperature-compensated charging for optimal charge levels and increased battery lifespan. They also match the appearance and footprint of the ups system cabinets. Larger models have heavy-gauge steel cabinets with 10-year design life batteries. smartOnline E3 series ups systems handle large battery systems with ease, providing up to 20 amps* of user-selectable charging capacity. * Varies with model.

5

BP480V26B

BP480V40C


COMpaCt FOOTPRINT Each smartOnline E3 series ups system packs enough power for multiple racks of equipment into a compact footprint, saving valuable data center floor space for critical systems and cooling. wall-mounted distribution and bypass panels do not require additional floor space.

OrderING INFORMATION MOdel

Output CapaCIty

NOMINal INput/Output vOltaGe

battery CONfIGuratION

Su20Kx

20 kVA / 16 kW

220/380, 230/400 or 240/415 VAC (3Ø, 4-wire + ground, wye)

Internal batteries; room for two additional SuRbC2030 internal battery packs; external battery cabinet optional.

220/380, 230/400 or 240/415 VAC

Internal batteries; external battery cabinet optional.

Su40Kx

40 kVA / 32 kW

(3Ø, 4-wire + ground, wye)

Su60Kx

60 kVA / 48 kW

220/380, 230/400 or 240/415 VAC

No internal batteries; external battery cabinet required.

(3Ø, 4-wire + ground, wye)

Su80Kx

80 kVA / 64 kW

220/380, 230/400 or 240/415 VAC

No internal batteries; external battery cabinet required.

(3Ø, 4-wire + ground, wye)

ExtERnaL battERy CabInEtS (Hardwire connection. multiple cabinets can be daisy-chained.) bp480v26b

+/- 240 VDC external battery cabinet. Supports temperature-compensated battery charging for optimal charge levels and increased battery lifespan. Matches appearance and footprint of uPS system cabinet.

bpe480vb

Empty +/- 240 VDC external battery cabinet (similar to bP480V26b without batteries). Requires 40 user-supplied batteries (12 VDC / 26 Ah). Includes wiring and fuses. Matches appearance and footprint of uPS system cabinet.

bp480v40C

+/- 240 VDC external battery cabinet. Supports temperature-compensated battery charging for optimal charge levels and increased battery lifespan. Matches appearance and footprint of uPS system cabinet.

bpe480vC

Empty +/- 240 VDC external battery cabinet (similar to bP480V40C without batteries). Requires 40 user-supplied batteries (12 VDC / 40 Ah). Includes wiring and fuses. Matches appearance and footprint of uPS system cabinet.

bp480v55

+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.

bp480v78

+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.

bp480v103

+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.

bp480v140

+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.

SurbC2030

240 VDC internal battery pack for Su20kX.

waLL-MoUntEd ExtERnaL MaIntEnanCE byPaSS PanELS wIth kEyEd SafEty IntERLoCk SyStEM Su20KMbpK

Maintenance bypass panel for Su20kX only. keyed safety interlock system prevents sequence of operation errors.

Su40KMbpKx

Maintenance bypass panel for Su40kX only. keyed safety interlock system prevents sequence of operation errors.

Su60KMbpKx

Maintenance bypass panel for Su60kX only. keyed safety interlock system prevents sequence of operation errors.

Su80KMbpKx

Maintenance bypass panel for Su80kX only. keyed safety interlock system prevents sequence of operation errors.

waLL-MoUntEd PaRaLLEL dIStRIbUtIon PanELS (Required for parallel connection of ups systems.) Supt20Kx

Parallel distribution panel for parallel connection of Su20kX models only.

Supt40Kx

Parallel distribution panel for parallel connection of Su40kX models only.

Supt60Kx

Parallel distribution panel for parallel connection of Su60kX models only.

Supt80Kx

Parallel distribution panel for parallel connection of Su80kX models only.

PowER ManagEMEnt aCCESSoRIES SNMpwebCard Adds Ethernet network interface to uPS system for remote monitoring and control via SNMP, Web or telnet. eNvIrOSeNSe

Monitors temperature and humidity. Monitors up to three additional sensors via contact closure interface. Requires SNMPWEbCARD.

waRRantIES and SERvICES Site survey services, start-up services, preventive maintenance services, extended warranties and on-site warranties are available. Visit www.tripplite.com or contact your Tripp Lite sales representative for more information.

6


TECHNICAL SPECIFICATIONS Model

SU20KX

Nominal Voltage

Input

Voltage Range

SU40KX

SU60KX

Full Load: 173 / 300 – 276 / 477 VAC (-25% / +20% @ 230/400 VAC) ≤ 70% Load: 120 / 208 – 276 / 477 VAC (-48% / +20% @ 230/400 VAC) < 4%

Power Factor (On-line, Full Load)

> 0,99 50/60 Hz

Frequency Tolerance

± 5% 53/50/48 A

79/76/73 A

105/101/97 A

45/43/41 A

Capacity (VA)

20 000 VA

40 000 VA

60 000 VA

80 000 VA

30 000 VA

Capacity (Watts)

16 000 W

32 000 W

48 000 W

64 000 W

24 000 W

Power Factor

0,8 Per Phase

Nominal Voltage

Output

± 3%

26/25/24 A

(@ 380/400/415 VAC, Per Phase)

User-Selectable: 220/380, 230/400 or 240/415 VAC (3Ø, 4-wire + ground, wye)

Frequency

50/60 Hz ± 0,05 Hz

Nominal Current (@ 380/400/415 VAC, Per Phase)

30/29/28 A

61/58/56 A

50/60 Hz ± 0,1 Hz

91/87/83 A

Waveform (On-line or Battery)

121/116/111 A

46/43/42 A

Pure Sine Wave ≤ 3%

THD (Linear Load) Voltage Regulation (Static) Overload Capacity

BREAKERS

176 / 304 – 288 / 499 VAC

> 0,95

Frequency (Auto-Selectable)

± 1%

± 2%

≤ 125% for 10 minutes; ≤ 150% for 60 seconds

≤ 125% for 60 sec; ≤ 150% for 30 sec

Rectifier (3-Pole, 600 VAC)

50 A

75 A

125 A

150 A

63 A

Bypass (3-Pole, 600 VAC)

50 A

75 A

125 A

150 A

63 A

Reserve (3-Pole, 600 VAC)

50 A

75 A

125 A

150 A

-

Output (3-Pole, 600 VAC)

50 A

75 A

125 A

150 A

-

Battery (Negative Pole, 600 VDC)

60 A

120 A

160 A

220 A

-

Standard Interface

LED/LCD Control Panel, RS-232, Contact Closure, EPO (Local and Remote)

Optional Interface

SNMPWEBCARD, ENVIROSENSE, RELAYIOCARD

Same as left, plus AS/400.

True On-line, Double Conversion; Voltage/Frequency Independent (VFI-SS-111) Operation; Complies with EU Directives (EN 62040-3)

UPS Topology Agency Approvals Efficiency

CE (EN 62040-1-1, EN 62040-2, EN 62040-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6), RoHS

CE (Same as left), GOST, SASO

Normal Mode: Up to 94% / Economy Mode: Up to 97%

Up to 93%

Transfer Time (Normal Mode)

General

SU30K3/3INT

User-Selectable: 220/380, 230/400 or 240/415 VAC (3Ø, 4-wire + ground, wye)

THDi (Full Load)

Nominal Current

SU80KX

0 ms

Ambient Operating Temperature

0° C to 40° C (32° F to 104° F)

Elevation

0 to 3 000 m (0 to 10 000 ft) ≤ 90%

≤ 95%

< 70 dBA

< 65 dBA

Humidity (Non-Condensing) Audible Noise (@ 1 m) 13 / 5,5+ min

13 / 5,5+ min

14 / 5,5+ min

10 / 3,5+ min

13 / 5+ min

(Internal Batteries)

(Internal Batteries)

(With BP480V26B)

(With BP480V40C)

(Internal Batteries)

Height

1 165 mm (45,9 in)

1 165 mm (45,9 in)

1 165 mm (45,9 in)

1 165 mm (45,9 in)

897 mm (35,3 in)

Width

520 mm (20,5 in)

520 mm (20,5 in)

520 mm (20,5 in)

520 mm (20,5 in)

490 mm (19,3 in)

Depth

855 mm (33,7 in)

855 mm (33,7 in)

855 mm (33,7 in)

855 mm (33,7 in)

940 mm (37,0 in)

267 kg (589 lb)

412 kg (908 lb)

210 kg (463 lb)

244 kg (538 lb)

284 kg (627 lb)

335 kg (739 lb)

480 kg (1 058 lb)

278 kg (613 lb)

312 kg (688 lb)

324 kg (715 lb)

Typical Runtime* (Half/Full Load)

Dimensions (Power Module)

Unit Weight

**

(Power Module)

Shipping Weight** (Power Module)

Runtime varies with load, battery condition and other factors. Runtime can be extended by connecting additional internal batteries (models SU20KX and SU30K3/3INT only) or external battery cabinets, sold separately. ** Weight includes internal batteries for models SU20KX, SU40KX and SU30K3/3INT.

*

7


SmartOnline T3 Series UPS Systems RELIABLE OPERATION SmartOnline T3 Series UPS Systems protect your equipment from power problems, including surges, line noise, harmonic distortion, electrical impulses, frequency variations, brownouts, overvoltages and blackouts. On-line operation continually transforms AC input power into filtered DC power, then resynthesizes it into precision-regulated AC

+ _ OPEN + _ + _

output with a pure sine wave. Reliable backup power with zero transfer time to battery keeps equipment operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. Fault-tolerant bypass features keep your equipment powered at all times—even if the UPS system requires

SU30K3/3INT

maintenance, repair or replacement.

OPEN OPEN

Versatile battery system SmartOnline T3 Series UPS Systems have an expandable, hot-swappable battery system

OPEN OPEN

with convenient front-panel access. Model SU30K3/3INT includes three internal battery packs and has room to add one additional SURBC2030 battery pack. Runtime can also be expanded with external battery cabinets. Each SUBF2030 external battery cabinet has room for up to four SURBC2030 battery packs.

SUBF2030 External Battery Cabinet

SURBC2030 Internal Battery Pack

Expand battery backup runtime by installing additional internal battery packs and/or external battery cabinets.

ORDERING INFORMATION Model

Output Capacity

Battery Configuration

SU30K3/3INT

30 kVA / 24 kW

Includes three internal battery packs; room for one additional SURBC2030 battery pack.

batterY expansion (Multiple battery cabinets can be daisy-chained.) SURBC2030

240 VDC internal battery pack for SmartOnline T3 UPS Systems and SUBF2030 external battery cabinets.

SUBF2030

External battery cabinet. Requires SURBC2030 battery packs (up to four per cabinet), sold separately.

BP240V99

240 VDC external battery cabinet with 10-year design life batteries.

BP240V120

240 VDC external battery cabinet with 10-year design life batteries.

BP240V1207C

240 VDC external battery cabinet with 10-year design life batteries. Built-in battery charger.

BP240V150

240 VDC external battery cabinet with 10-year design life batteries.

BP240V1507C

240 VDC external battery cabinet with 10-year design life batteries. Built-in battery charger.

Wall-Mounted External Maintenance Bypass Panels with Keyed Safety Interlock System SU30KMBPK

Maintenance bypass panel for 30 kVA models. Keyed safety interlock system prevents sequence of operation errors.

POWER Management Accessories SNMPWEBCARD

Adds Ethernet network interface to UPS system for remote monitoring and control via SNMP, Web or telnet.

ENVIROSENSE

Monitors temperature and humidity. Monitors up to three additional sensors via contact closure interface. Requires SNMPWEBCARD.

RELAYIOCARD

Programmable contact closure accessory card with six output contacts and one input contact.

Warranties and Services Site survey services, start-up services, preventive maintenance services, extended warranties and on-site warranties are available. Visit www.tripplite.com or contact your Tripp Lite sales representative for more information.

About Tripp Lite Since 1922, Tripp Lite has established a global reputation for quality manufacturing, superior value and excellent service. Tripp Lite makes more than 1 000 products to power, protect and connect electronic equipment, including UPS systems, replacement batteries, power distribution units, rack systems, surge suppressors, KVM switches, cables, laptop accessories, power strips and inverters. Learn more at www.tripplite.com.

Tripp Lite World Headquarters 1111 W. 35th Street, Chicago, IL 60609 USA, +1.773.869.1212, www.tripplite.com Tripp Lite América Latina (Miami) +1.305.406.2523, info_la@tripplite.com • Tripp Lite Chile (Santiago) +562.433.0301, info_la@tripplite.com Tripp Lite Middle East (Dubai) +971.4.887.1633, salesint@tripplite.com • Tripp Lite Russia (Moscow) +7.495.799.5607, inforu@tripplite.com Tripp Lite Belgium +32.2.582.9946, salesint@tripplite.com

Copyright © 2009 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.

200802240 95-2917


Turn static files into dynamic content formats.