SmartPro Shallow-Depth Rackmount UPS Systems SmartPro® Shallow-Depth Rackmount UPS Systems are designed for applications that require shallower mounting depth, higher load capacity and/or longer battery backup runtime than standard models. They're ideal for protecting and supporting network/telecom wiring closets, servers, storage and security systems. SYST RPS

• Best-in-class mounting depth, wattage and internal battery capacity MASTR STAT

DUPLX SPEE D STAC K

MOD

E

15X

Ideal Mounting Depth For Network Applications

• Runtime is expandable via external battery packs, including new shallow-depth models SYST RPS

MAS TR STAT DUPLX SPEED STAC K

MOD

31X 33X

• Advanced automatic voltage regulation protects equipment from voltage fluctuations E

15X

SYST RPS

47X

MAS TR STAT DUPLX SPEED STAC K

• Pure sine wave output guarantees maximum equipment safety and stability MOD

31X 33X

Reduced Energy Costs: Up to 97% Efficiency

50

E

15X

• Optional SNMPWEBCARD enables monitoring and control via SNMP, Web or telnet SYST RPS MAS TR STAT

47X

DUP LX SPEED STACK

MOD

31X 33X

E

50 15X

SYS T RPS MAS TR STAT DUP LX SPE ED STACK

MOD

47X

31X 33X

E

50 15X

MOD

SYS T RPS MAS TR STAT DUP LX SPE ED STACK

47X

31X 33X

E

50 15X

47X

31X 33X

50

47X

50

H

EPT

17.

NT

OU

M 75”

D ING

SMART2200CRMXL shown in 2-post rack with Cisco® Catalyst® network switches

SMART3000CRMXL (3000VA/2880W with 3600VA/3600W hardwire option; 4U; 120V input/output; 17.75" depth)

2

SMART2200CRMXL (2200VA/1900W; 4U; 120V input/output; 17.75" depth)

3

SMART1500CRMXL (1500VA/1440W; 2U; 120V input/output; 19.5" depth)

4

1111 W. 35th Street, Chicago, IL 60609 USA (773) 869-1234 • www.tripplite.com Copyright © 2008 Tripp Lite. All rights reserved. Tripp Lite's PowerAlert Software, version 12.5, has tested compatible with Cisco CallManager, versions 4.0 and 4.1, Cisco 7600 Series Routers, 7500 Series Routers and Catalyst 65XX Layer 3 Switch. Tripp Lite PowerAlert Software, version 12, has tested compatible with Cisco CallManager, versions 3.3(4)-MCS and 4.0(2)-MCS. Go to www.tripplite.com/logodisclaimer for details. Tripp Lite is a Cisco Technology Developer Partner in the Cisco Technology Developer Program. Cisco, Cisco Systems, Catalyst, the Cisco Systems logo, and the Cisco Square Bridge logo are registered trademarks or trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. SmartPro is a registered trademark of Tripp Lite. All other trademarks are the property of their respective owners. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.


SmartPro Shallow-Depth Rackmount UPS System Model: SMART3000CRMXL • Up to 3,600VA / 3,600W Capacity • Increased Internal Battery Capacity • Automatic AC Bypass

• Advanced Automatic Voltage Regulation • 120V Pure Sine Wave Output • Remotely Switchable Outlet Banks

Advantages: High Wattage, Shallow Mounting Depth, Longer Runtime at Comparable Load Levels

Front View Includes 2-Post Rackmount Kit Enables mounting in standard 2-post (telecom) racks. For 4-post rackmount applications, order one UPSRMRII mounting kit per UPS or battery pack.

4U

17.75

-inch

Depth

Equals or Surpasses APC Models in Key Areas

All-In-One: Power and Battery

Load Internal Battery Mounting Capacity Capacity Depth Tripp Lite SMART3000CRMXL 3,600W* 864 WH 17.75 in. APC SUA3000RM2U 2,700W 480 WH 26 in. APC SUA3000RMXL3U 2,700W 864 WH 26 in. APC SUM3000RMXL2U 2,850W 480 WH 26.7 in.

Rear View

Model B

E

C D

G

* Hardwire option. K

17.75

-inch

Optional Accessories External Battery Packs

Depth A

N

H

I

F

J

M

Battery packs extend runtime for mission-critical systems.

L

• Model BP48V48RT4U has a shallow mounting depth, making it ideal for SMART3000CRMXL. Multiple units can be daisy-chained for additional expansion.

AC Input Connection (120V, 30A Supply Circuit) Hardwire Option Maximum Input: 30A Maximum Output: 3,600W

L5-30P Plug with 10 ft. Cord Maximum Input: 24A Maximum Output: 2,880W

(Remove included cord/plug and wire UPS directly to supply circuit. For output > 2,880W use internal batteries only.)

A External Battery Pack* Connector (Enables Extended Runtime Capability) B SNMP/Web Accessory Card Slot for Remote Monitoring, Reboot and Shutdown** D Emergency Power Off (EPO) Connector C Charge Rate Switch E HID-Compliant USB and RS-232 Serial (DB9) Communication Ports*** H 5-15R Outlets F L5-30R Outlet G 5-15/20R Outlets I Output Breakers J AC Bypass Alarm Enable/Disable Switch L 10 ft. Cord with L5-30P Twist-Lock Plug K Input Breaker M Optional Hardwire Input N Wiring Access Panel Internal Features (Not Shown): Ventilation Fans, AC Bypass****

Note: BP48V48RT4U includes 2-post rackmount hardware. For 4-post rackmount applications, order one UPSRMRII per battery pack. BP48V60RT3U and BP48V24-2U include 4-post rackmount hardware. For 2-post rackmount applications, order one 2POSTRMKITWM per battery pack.

3,000VA (L5-30P) / 3,600VA (Hardwire) 2,880W (L5-30P) / 3,600W (Hardwire) 120V AC, 60 Hz. 4 (5-15R), 4 (5-15/20R), 1 (L5-30R) 3 banks of 1 Hardwire or L5-30P with 10 ft. cord 19 min./7.5 min. (L5-30P)* 4U** 1 RS-232 (DB9), 1 USB, 1 EPO 7 x 17.25 x 17.75 in., 102 lb.

22 102 178 257

15 72 128 186

12 55 98 144

9.1 44 79 116

7.7 36 65 96

6.1 — — —

3U

inc

hD

ept

h

BP48V60RT3U

13.5-

inch

2U

Depth

4-Post Rackmount Kit (Model: UPSRMRII)

Internal SNMP/Web Card (Model: SNMPWEBCARD) Allows users to operate the UPS as a managed device on a network. Enables remote monitoring, shutdown, reboot and more using SNMP network management system, Web browser or telnet.

Estimated Runtime (Minutes)* 36 163 281 400

26-

Enables 4-post rackmount installation for compatible rackmount UPS systems and battery packs. Order one kit per UPS system or battery pack.

400W 800W 1200W 1,600W 2,000W 2,400W 2,800W 3,200W** 3,600W** 83 349 581 812

BP48V48RT4U

BP48V24-2U

* Full load runtime for hardwire option (3,600W; internal batteries only) is 5 minutes. ** Mounting Options: 2-post rackmount with included mounting kit; 4-post rackmount with UPSRMRII (available separately).

Internal Batteries +1 BP48V48RT4U +2 BP48V48RT4U +3 BP48V48RT4U

Depth

• Model BP48V24-2U is only 2U high and has a shallow mounting depth, but it has less battery capacity and cannot be daisy-chained.

* Model BP48V48RT4U, BP48V60RT3U or BP48V24-2U available separately from Tripp Lite. ** For use with internal accessory card model SNMPWEBCARD available separately from Tripp Lite. *** PowerAlert Software CD-ROM and cabling included. **** In case of processor fault or internal battery depletion, the bypass routes AC power to the outlets.

Output Capacity (VA): Output Capacity (Watts): Input/Output Voltage & Frequency (Nominal): AC Outlet Quantity (Type): Remotely Switchable Outlets Input Connection: Runtime, Half/Full Load (Typical): Total Rack Space: Communication Ports: Unit Dimensions (H x W x D, Weight)

-inch

• Model BP48V60RT3U requires less vertical rack space, but it has a longer mounting depth. Multiple units can be daisy-chained for additional expansion.

Features

Specifications

4U 17.75

5.1 — — —

Remove the accessory slot cover B to insert internal SNMPWEBCARD.

* Runtime varies with load, battery condition and other factors. ** For output >2,880W use internal batteries only.

Tripp Lite World Headquarters: 1111 W. 35th Street, Chicago, IL 60609 USA, (773) 869-1234, www.tripplite.com

2


SmartPro Shallow-Depth Rackmount UPS System Model: SMART2200CRMXL • 2,200VA / 1,900W Capacity • Increased Internal Battery Capacity • Automatic AC Bypass

• Advanced Automatic Voltage Regulation • 120V Pure Sine Wave Output • Remotely Switchable Outlet Banks

Advantages: High Wattage, Shallow Mounting Depth, Longer Runtime at Comparable Load Levels

Front View Includes 2-Post Rackmount Kit Enables mounting in standard 2-post (telecom) racks. For 4-post rackmount applications, order one UPSRMRII mounting kit per UPS or battery pack.

4U

17.75

-inch

Depth

Equals or Surpasses APC Models in Key Areas All-In-One: Power and Battery

Load Internal Battery Mounting Capacity Capacity Depth Tripp Lite SMART2200CRMXL 1,900W 864 WH 17.75 in. APC SUA2200RM2U 1,980W 480 WH 26 in. APC SUA2200RMXL3U 1,850W 864 WH 26 in. Model

Rear View B

Optional Accessories

E

C D

F

External Battery Packs

I

17.75

-inch

Battery packs extend runtime for mission-critical systems.

Depth H

G

A

• Model BP48V48RT4U has a shallow mounting depth, making it ideal for SMART2200CRMXL. Multiple units can be daisy-chained for additional expansion.

J

AC Input Connection: Insert 5-20P plug into compatible outlet. (Replaceable with user-supplied 5-15P.) A External Battery Pack* Connector (Enables Extended Runtime Capability) B SNMP/Web Accessory Card Slot for Remote Monitoring, Reboot and Shutdown**

Note: BP48V48RT4U includes 2-post rackmount hardware. For 4-post rackmount applications, order one UPSRMRII per battery pack. BP48V60RT3U and BP48V24-2U include 4-post rackmount hardware. For 2-post rackmount applications, order one 2POSTRMKITWM per battery pack.

* Model BP48V48RT4U, BP48V60RT3U or BP48V24-2U available separately from Tripp Lite. ** For use with internal accessory card model SNMPWEBCARD available separately from Tripp Lite. *** PowerAlert Software CD-ROM and cabling included. **** In case of processor fault or internal battery depletion, the bypass routes AC power to the outlets.

2,200VA/1,900W 120V AC, 60 Hz. 4 (5-15/20R), 4 (5-15R) 3 banks of 1 5-20P with 10 ft. cord 28 min./11 min. 4U* 1 RS-232 (DB9), 1 USB, 1 EPO 7 x 17.25 x 17.75 in., 100 lb.

Internal Batteries 177 +1 BP48V48RT4U 788 +2 BP48V48RT4U 1,271 +3 BP48V48RT4U 1,738

82 400 662 922

51 260 439 618

27 146 253 361

21 116 202 291

17 95 168 242

3U

inc

hD

ept

h

BP48V60RT3U

13.5-

inch

2U

Depth

4-Post Rackmount Kit (Model: UPSRMRII)

800W 1,000W 1,200W 1,400W 1,600W 36 190 324 459

26-

Enables 4-post rackmount installation for compatible rackmount UPS systems and battery packs. Order one kit per UPS system or battery pack.

Internal SNMP/Web Card (Model: SNMPWEBCARD) Allows users to operate the UPS as a managed device on a network. Enables remote monitoring, shutdown, reboot and more using SNMP network management system, Web browser or telnet.

Estimated Runtime (Minutes)* 600W

BP48V48RT4U

BP48V24-2U

* Mounting Options: 2-post rackmount with included mounting kit; 4-post rackmount with UPSRMRII (available separately).

200W 400W

Depth

• Model BP48V24-2U is only 2U high and has a shallow mounting depth, but it has less battery capacity and cannot be daisy-chained.

D Emergency Power Off (EPO) Connector C Charge Rate Switch E HID-Compliant USB and RS-232 Serial (DB9) Communication Ports*** F 5-15/20R Outlets G 5-15R Outlets H AC Bypass Alarm Enable/Disable Switch J 10 ft. Cord with 5-20P Plug I Input Breaker Internal Features (Not Shown): Ventilation Fans, AC Bypass****

Output Capacity (VA/Watts): Input/Output Voltage & Frequency (Nominal): AC Outlet Quantity (Type): Remotely Switchable Outlets Input Plug (Type): Runtime, Half/Full Load (Typical): Total Rack Space: Communication Ports: Unit Dimensions (H x W x D, Weight):

-inch

• Model BP48V60RT3U requires less vertical rack space, but it has a longer mounting depth. Multiple units can be daisy-chained for additional expansion.

Features

Specifications

4U 17.75

14 80 142 206

1,800W 12 69 123 179

Remove the accessory slot cover B to insert internal SNMPWEBCARD.

* Runtime varies with load, battery condition and other factors.

Tripp Lite World Headquarters: 1111 W. 35th Street, Chicago, IL 60609 USA, (773) 869-1234, www.tripplite.com

3


SmartPro Shallow-Depth Rackmount UPS System Model: SMART1500CRMXL • 120V Pure Sine Wave Output • Remotely Switchable Outlet Banks

• 1,500VA / 1,440W Capacity in Only 2U • Advanced Automatic Voltage Regulation

Advantages: High Wattage, Shallow Mounting Depth

Front View Includes 4-Post Rackmount Kit

Enables mounting in standard 4-post racks and rack enclosures. For 2-post (telecom) rackmount applications, order one 2POSTRMKITWM mounting kit per UPS or battery pack.

2U 19.5

-inc

h De

pth

All-In-One: Power and Battery

Equals or Surpasses APC Models in Key Areas Model Tripp Lite SMART1500CRMXL APC SUM1500RMXL2U

Rear View

Load Capacity 1,440W 1,424W

Mounting Depth 19.5 in. 26.7 in.

E D

C

19.

5-i

nch

Optional Accessories External Battery Packs Battery packs extend runtime for mission-critical systems.

Dep

th

A

F

B

G

• Model BP48V48RT4U has a shallow mounting depth. Multiple units can be daisy-chained for additional expansion.

I

H

• Model BP48V60RT3U requires less vertical rack space, but it has a longer mounting depth. Multiple units can be daisy-chained for additional expansion.

AC Input Connection: Insert 5-15P plug into compatible outlet.

Features A External Battery Pack* Connector (Enables Extended Runtime Capability) C SNMP/Web Accessory Card Slot for Remote Monitoring, Reboot and Shutdown** D 5-15R Outlets E Input Breaker F Charge Rate Switch G Emergency Power Off (EPO) Connector H HID-Compliant USB and RS-232 Serial (DB9) Communication Ports*** I 10 ft. Cord with 5-15P Plug

Note: BP48V48RT4U includes 2-post rackmount hardware. For 4-post rackmount applications, order one UPSRMRII per battery pack. BP48V60RT3U and BP48V24-2U include 4-post rackmount hardware. For 2-post rackmount applications, order one 2POSTRMKITWM per battery pack.

Depth

BP48V48RT4U

26-

3U

inc

hD

ept

h

BP48V60RT3U

13.5-

inch

2U

Depth

BP48V24-2U

* Model BP48V48RT4U, BP48V60RT3U or BP48V24-2U available separately from Tripp Lite. ** For use with internal accessory card model SNMPWEBCARD available separately from Tripp Lite. *** PowerAlert Software CD-ROM and cabling included.

Output Capacity (VA/Watts): Input/Output Voltage & Frequency (Nominal): AC Outlet Quantity (Type): Remotely Switchable Outlets Input Plug (Type): Runtime, Half/Full Load (Typical): Total Rack Space: Communication Ports: Unit Dimensions (H x W x D, Weight):

-inch

• Model BP48V24-2U is only 2U high and has a shallow mounting depth, but it has less battery capacity and cannot be daisy-chained.

B Ventilation Fan

Specifications

4U 17.75

2-Post Rackmount Kit (Model: 2POSTRMKITWM)

1,500VA/1,440W 120V AC, 60 Hz. 8 (5-15R) 3 banks of 1 5-15P with 10 ft. cord 14 min./6 min. 2U* 1 RS-232 (DB9), 1 USB, 1 EPO 3.5 x 17.25 x 19.5 in., 60 lb.

Enables 2-post rackmount installation for compatible rackmount UPS systems and battery packs. Order one kit per UPS system or battery pack.

* Mounting Options: 4-post rackmount with included rackmount rails; 2-post rackmount with 2POSTRMKITWM (available separately); tower mount with 2-9USTAND (available separately).

Internal SNMP/Web Card (Model: SNMPWEBCARD) Estimated Runtime (Minutes)* Internal Batteries +1 BP48V24-2U

200W

400W

600W

800W

1,000W

1,200W

1,400W

69 299

30 141

18 88

12 61

10 46

7.9 36

6.3 29

Allows users to operate the UPS as a managed device on a network. Enables remote monitoring, shutdown, reboot and more using SNMP network management system, Web browser or telnet.

* Runtime varies with load, battery condition and other factors.

Remove the accessory slot cover C to insert internal SNMPWEBCARD.

Tripp Lite World Headquarters: 1111 W. 35th Street, Chicago, IL 60609 USA, (773) 869-1234, www.tripplite.com

4

200809031 95-2963


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.