CitySense Installation Manual
English
ATTENTION: In order to function properly, CitySense must be connected to a dimmable driver/ballast. NOTE: Some dimmable drivers/ballasts must be programmed/set to dimmable mode. If this has not been done, CitySense will not be able to dim the connected armature. Ensure that the armature is connected using a 5-core cable. If this has not been done, CitySense will not be able to dim the connected armature.
TVILIGHT BV / Westerhaven 13, 9718 AW Groningen, the Netherlands +31 (0)50 800 3240 / info@tvilight.com / www.tvilight.com
v 1.2 22/04/2015
In box:
5m Cable
Rubber Grommet
You’ll need: Drill
16mm
Generic Strap x 2
Max = 13mm Min = 8mm
Level
Wago/3M ScotchLok Connector
Screw Driver
Page 1 of 7
1. Run wire through grommet
2. Drill 16mm hole into pole
5m
Page 2 of 7
3. Run wire through hole
4. Push grommet into hole Use a screw driver to press grommet into the hole
Page 3 of 7
5. Strap product to pole
Generic Strap x 2
6. Level the product
Page 4 of 7
7. Apply product ID sticker to pole
SAME
5 cm
Page 5 of 7
Wiring Diagram
Connector (e.g. Wago/3M ScotchLok)
WARNING: If not correctly connected product will not function.
DC -
AC in(N)
DC +
Grey
Blue
AC in(L)
Purple/Black
Brown
Junction Box
AC in(N)
AC in(L)
DC +
DC -
Page 6 of 7
Wiring Diagram Armature (Armatuur) GND DC - DC + LL NN GND DCDC+
WARNING:
Tvilight CitySense
If not correctly connected product will not function.
DC+ DCDC + DC -
LL
N N
Connector DC + DC+
Connector
Junction Box
DC DC-
(Aansluitset) LL N N
LL NN GND GND
GND GND
AC in(L) AC in(N)
Brown
Blue
DC +
Purple/Black
DC -
Grey
AC1 AC2 AC3 AC1
AC2
AC3
To Mains (Naar Mains)
Note: For added protection, it is recommended to add an external circuit breaker at the power input of the product. Circuit breakers such as the TYCO W33-S1N1Q-20 or similar rated products could be used for the same.
Page 7 of 7