V E N T I L AT I O N S S Y S T E M
PlanlĂŚgnings- og installationsvejledning
04 I 2010 31701
Indhold Uponor PP plast ventilationskanaler og -komponenter ...................................................................4 Materialedata ......................................................................................................................................4 Tekniske data for kanaler .....................................................................................................................4 Tekniske data for kanalisolering ...........................................................................................................5 Kvalitet ................................................................................................................................................5 Mål og tolerancer.................................................................................................................................5 Kanalernes tæthed...............................................................................................................................5 Emballage ............................................................................................................................................5 Opbevaring ..........................................................................................................................................5 Ventilationskanaler og -komponenter ................................................................................................6 Ventilationskanaler ....................................................................................................................................6 Ventilationskomponenter.....................................................................................................................6 Præ-isolerede ventilationskanaler ........................................................................................................8 Præ-isolerede ventilationskomponenter ..............................................................................................8 Armaturer og ventiler........................................................................................................................10 Konstruktion af ventilationssystem.............................................................................................12 Definitioner .......................................................................................................................................12 Anvendelser for Uponor ventilationskanaler ......................................................................................12 Køkken emhætte/ventilator kanaler ..................................................................................................12 Placering af kanaler ...........................................................................................................................12 Offentlige regler ................................................................................................................................12 Isolering af kanalerne ........................................................................................................................12 Ventilation af saunarum .....................................................................................................................12 Dimensionering af kanaler og lyddæmpere .................................................................................15 Lyddæmpernes lyddæmpning pr oktav, ISO 7235:2003.....................................................................19 Lyddæmpernes tryktab, ISO 7235:2003 ............................................................................................19 Lyddæmpernes tryktab, ISO 7235:2003 USI-125-300, USI-125-650 og USI-125-1000.............................................................................20 USI-160-650 og USI-160-1000 ...................................................................................................20
2
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Installation............................................................................................................................................21 Oversigt .............................................................................................................................................21 Kanalføring ........................................................................................................................................21 Kanalføring gennem dampspærrer .....................................................................................................22 Kanalføring af præ-isolerede kanaler gennem dampspærrer ..............................................................22 Understøtninger ................................................................................................................................23 Understøtning af præ-isolerede kanaler ............................................................................................23 Isolering ........................................................................................................................................24 Installation og indstilling af luftarmaturer ...............................................................................................26 Oversigt .............................................................................................................................................26 Tilslutning af luftarmaturer til kanalerne............................................................................................26 Friskluftrist ........................................................................................................................................27 Friskluftsarmatur til vægmontage ......................................................................................................27 Friskluftsarmatur til ventilationshul ...................................................................................................27 Spalteventil........................................................................................................................................28 Friskluftsarmatur ...............................................................................................................................28 Justering af armaturer .......................................................................................................................28 Tabeller over armatur fabriksindstillinger, trykdifferens 20 Pa..................................................29 Luftstrøm, trykdifferens og støjniveau .......................................................................................30 Luftstrøm og trykdifferens ..........................................................................................................32
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
3
Uponor PP plast ventilationskanaler og -komponenter Instruktionerne i denne manual er udarbejdet til brug for implementering af lejligheds-adskilte ventilationssystemer i fritliggende huse, terrassehuse eller rÌkkehuse. I terrassehuse og rÌkkehuse skal der vÌre fuldstÌndig strukturel brandadskillelse af boligenes loftsrum. Uponors produktsortiment er blevet opdateret, og vi introducerer nu prÌ-isolerede ventilationskanaler og -kanalsektioner pü markedet. Et isoleret kanalsystem tillader en sikrere køling af indsugningsluften, og der mistes ikke energi i strukturen. Pü den anden side er fabriksisolerede kanaler i den øverste tagisolering "sikre", og det gør det lettere at undgü kondens og risici pga. installationsfejl.
• Teknisk excellent struktur for luftgennemstrømning • Ingen korrosionsproblemer • Ingen lugtproblemer • Garanteret ren indeluft i hele hjemmet • Patenterede struktur- og samlingsløsninger
MaterialespeciďŹ kationer RĂĽmaterialer:
polypropylen; lugtfri og ugiftig
Tekniske data for kanalisolering
Farve:
blĂĽ
Massefylde:
≈ 900 kg/m3
Brudstyrke:
30 MPa
Tekniske data for kanaler Den indvendige overade pü kanaler er ren og fri for ujÌvnheder.
• Vores produktudvalg indeholder fabriksfÌrdige, prÌ-isolerede kanaler og kanalsektioner.
Modstandsdygtighed mod slag: Opfylder kraven angivet i SFS-EN 1411.
• Opsamler ikke støv eller snavs: Antistatisk PP materiale modstür enhver forurening.
Korrosionsbestandighed: Kemisk modstandsdygtighed som beskrevet i standarden ISO/TR 10358
• Hurtig og nem installation. • Let bearbejdelige materialer. • Kanalerne kan installeres uden separat forsegling og lüsning.
Antistatiske egenskaber: Antistatiske produkter. De antistatiske egenskaber af kanalernes og komponenternes indre overader müles under produktionen i overensstemmelse med testproceduren i ANSI/EOS/ESD-S11.11.
!
KanalmĂŚrkning
4
" #
Kuldebestandighed: Den lavest anbefalede temperatur er -15°C. Kuldebestandigheden veriďŹ ceres gennem konstant kvalitetskontrol i g. testmetoderne i SFS/ EN 1411. RenhedsklassiďŹ kation: Renhedsklasse M1. Udviklet i samarbejde med det ďŹ nske Astma- og Allergiforbund.
Varmeudvidelse: 0,06 mm/m °C • Alle kanaler og komponenter er rene og beskyttede fra produktion til installation.
Varmebestandighed: Kontinuerlig –50°C...+85°C, kortvarigt +100 °C.
$ % %! ' '( %! ' '( & ' # )#' ##* & #
RĂĽmaterialer: polyĂŚtylen skum Farve: BlĂĽ Massefylde: 30 kg/m3, isolering tykkelse 15 mm U-vĂŚrdi 0,037 W/ m x K Brandsikkerhed: Ingen brandklassiďŹ cering. VTT studier: - En fabriksisoleret ventilationskanal til 1 – 2 familiehuse eller rĂŚkkehuse Laboratorietest for overade temperatur Dato 6. november 2006 En computerberegning af den nødvendige isolerings tykkelse for at hindre kondens og begrĂŚnse produktets varmetab udviklings- og laboratoriums- afprøvning Dato 10. maj 2006
" ' +,% ' -)+,#') ,
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Lyddæmpere
Kvalitet
Kanalernes tæthed
Lyddæmperne er udført i PE plast. Lyddæmperne er testet af VTT Technical Research Centre of Finland, Certifikat Nr. VTT-S-03839-07 Dato 24.04.2007
Uponors plast ventilationssystem kanaler er blevet tildelt et VTT produktcertifikat.
Kanalerne opfylder lufttæthedsklasse D. Kanalerne skal tilsluttes i overensstemmelse med instruktionerne i denne manual. Forbindelserne kan ikke limes sammen, fordi opløsningsmidlerne ikke virker på polypropylen.
- Firkantede lyddæmpere med runde kanaltilslutninger - Lille vægt og lette at håndtere - Fremragende lyddæmpende egenskaber - Modstandsdygtige mod slag og korrosion - Sort farve - Det indvendige lyddæmpende materiale er Dacron - Ingen løse fibre eller fugtabsorption - Ingen irritation af hud eller åndedræt - Ingen lugt eller støbeproblemer
Mål og tolerancer Kanalstørrelserne er ø 100 (+0.5) mm, ø 125 (+0.5) mm, ø 160 (+0.6) mm og ø 200 (+0.7) mm. Tolerancerne opfylder kanalstandarden SFS 3282. Tolerancerne for de sprøjtestøbte komponenter er bedre end standarden kræver. Uponors ventilationskanaler og -komponenter er kompatible med kanalkomponenter, der opfylder standarden SFS 3282.
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Emballage Kanalerne leveres lukkede i begge ender for at holde dem rene. Kanalkomponenterne leveres i plastposer og papkasser. Opbevaring Modstår udendørs oplagring i centraleuropæisk klima. Kanalerne er UV-beskyttede. Højst 2 lag oven på hinanden.
5
Ventilationskanaler og -komponenter
Ventilationskanaler Materiale: Polypropylen. Farve: blå.
Ventilationskanal Leveres i længder på 3 meter. %
'
.
di x l
Uponor nr.
VVS nr.
s
100 x 3000
1046152
35.3500.100
2,1
125 x 3000
1046153
35.3500.125
2,1
160 x 3000
1046154
35.3500.160
2,5
200 x 3000
1046155
35.3500.200
3,0
Ventilationskomponenter Materiale: Polypropylen. Farve: Blå. Bøjning 45° %
do x α
VVS nr
l1
l2
100 x 45°
1046172
35.3502.100
46
40
125 x 45°
1046173
35.3502.125
36
50
160 x 45°
1046174
35.3502.160
45
50
200 x 45°
1046171
35.3502.200
54
50
Uponor nr.
VVS nr.
l1
l2
100 x 90°
1046168
35.3501.100
81
40
125 x 90°
1046169
35.3501.125
84
50
160 x 90°
1046170
35.3501.160
160
50
200 x 90°
1046167
35.3501.200
130
50
do1/do2
Uponor nr.
VVS nr.
l1
l2
l3
100/100
1046175
35.3503.100
142
40
71
125/100
1046179
35.3503.124
144
50
81
125/125
1046176
35.3503.125
168
50
81
160/100
1046180
35.3503.158
144
50
98
160/125
1046177
35.3503.159
168
50
101
160/160
1046178
35.3503.160
196
50
100
200/160
1046181
35.3503.199
202
50
118
%
Uponor nr.
%
%
α
Bøjning 90° %
%
%
%
α
do x α
T-stykker %
%
%
%
6
%
%
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Ventilationskomponenter Materiale: Polypropylen. Farve: Blå.
Samlenippel % %
%
Prop
do
Uponor nr.
VVS nr.
l1
l2
100
1046164
35.3508.100
83
40
125
1046165
35.3508.125
103
50
160
1046166
35.3508.160
103
50
200
1046163
35.3508.200
103
50
Uponor nr.
VVS nr.
do3
l1
l2
100
1046182
35.3506.100
120
43
40
125
1046183
35.3506.125
145
33
30
125/160
1046184
35.3506.159
180
53
50
do1/do2
Uponor nr.
VVS nr.
l2
l3
l4
100/125
1046185
35.3504.124
50
20
40
125/160
1046186
35.3504.159
51
30
50
160/200
1046187
35.3504.199
51
40
50
% %
do1/do2
100 % %
125
% %
125/160
Reduktionsstykke %
%
%
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
7
Præ-isolerede ventilationskanaler Kanalmateriale: Polypropen. Farve: Blå. Isoleringsmateriale: Polyætylen skum Farve: Blå Isoleringstykkelse: 15 mm
Ventilationskanal l
Leveres i længder på 3 meter. Uponor nr.
VVS nr.
100 x 3000
1046156
35.3510.100
125 x 3000
1046157
35.3510.125
160 x 3000
1046158
35.3510.160
200 x 3000
1046159
35.3510.200
s
di
di x l
Præ-isolerede ventilationskomponenter Kanalmateriale: Polypropen. Farve: Blå. Isoleringsmateriale: Polyætylen skum Farve: Blå Isoleringstykkelse: 15 mm
Bøjning 45° do x α
Uponor nr.
VVS nr.
100 x 45°
1046197
35.3512.100
125 x 45°
1046198
35.3512.125
160 x 45°
1046199
35.3512.160
200 x 45°
1046196
35.3512.200
Uponor nr.
VVS nr.
100 x 90°
1046193
35.3511.100
125 x 90°
1046194
35.3511.125
160 x 90°
1046195
35.3511.160
200 x 90°
1046192
35.3511.200
do1/do2
Uponor nr.
VVS nr.
100/100
1046200
35.3513.100
125/100
1046204
35.3513.124
125/125
1046201
35.3513.125
160/100
1046205
35.3513.158
160/125
1046202
35.3513.159
160/160
1046206
35.3513.160
200/160
1046203
35.3513.199
Bøjning 90° do x α
T-stykker
8
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Samlenippel
do
Uponor nr.
VVS nr.
100
1046189
35.3518.100
125
1046190
35.3518.125
160
1046191
35.3518.160
200
1046188
35.3518.200
Uponor nr.
VVS nr.
100
1046207
35.3516.100
125
1046208
35.3516.125
125/160
1046209
35.3516.159
do1/do2
Uponor nr.
VVS nr.
100/125
1046210
35.3514.124
125/160
1046211
35.3514.159
160/200
1046212
35.3514.199
Prop do1/do2
100
125
125/160
Reduktionsstykke
Aluminiumsspændbånd Produkt
Aluminiumsspændbånd 5 stk. / pose
Uponor nr.
VVS nr.
1046258
35.3529.800
Kanalføring gennem dampspærre %
Selvklæbende PE-plast. Uponor nr.
VVS nr.
l1
l2
tykkelse
100
1046252
35.3529.010
240
240
10
125
1046251
35.3529.012
240
240
10
%
Mål d1
Lyddæmper
Firkantet, indvendigt lyddæmpene materiale er Dacron Tilslutningsdiameter og model
Uponor nr.
VVS nr.
l1
l2
l3
USI - 125 - 300
1046253
35.3529.123
300
190
270
USI - 125 - 650
1046254
35.3529.126
650
190
270
USI - 125 - 1000
1046255
35.3529.120
1000
190
270
USI - 160 - 650
1046256
35.3529.166
650
225
300
USI - 160 - 1000
1046257
35.3529.160
1000
225
300
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
9
Armaturer og ventiler
Standardfarve: Hvid.
Indblæsningsarmaturer (mekanisk ventilation)
0
0
Lofts-monterede armaturer
Tilslutningsdiameter og model
Uponor nr.
VVS nr.
D
D1
H
UTK-100
1046266
35.3520.110
140
98
60
UTK-C-100, krom
1046267
35.3520.114
140
98
60
UTK-B-100, messing
1046268
35.3520.116
140
98
60
1046269
35.3520.210
140
98
60
* UTK-S-100, sauna * UTK-S-B-100, sauna messing
/
Vægmonterede armaturer
Armaturkrave
1046270
35.3520.216
140
98
60
UTK-125
1046271
35.3520.120
175
115
67
UTK-C-125, krom
1046272
35.3520.124
175
115
67
UTK-B-125, messing
1046273
35.3520.126
175
115
67
* UTK-S-125, sauna
1046274
35.3520.220
175
115
67
* UTK-S-B-125, sauna messing
1046275
35.3520.226
175
115
67
UKK-125, armaturkrave
1046227
35.3520.820
166
135
55
UTS-100
1046226
35.3520.410
Mål i billedet
UTS-125
1046218
35.3520.420
Mål i billedet
* Varmebestandigt op til 200°C. Ved brug af saunaarmaturet, brug altid kraven i emballagen.
Udsugningsarmaturer (mekanisk ventilation)
0
0
Loftsmonterede armaturer
0
0
/
Tilslutningsdiameter og model
Uponor nr.
VVS nr.
D
D1
UPK-100
1046214
35.3521.110
138
72
50
UPK-C-100, krom
1046228
35.3521.114
138
72
50
UPK-M-100, messing
1046229
35.3521.116
138
72
50
UPK-125
1046213
35.3521.120
168
90
60
UPK-C-125, krom
1046230
35.3521.124
168
90
60
UPK-M-125, messing
1046231
35.3521.126
168
90
60
* UPK-S-100 med træknop
1046232
35.3521.210
138
72
50
* UPK-S-125, med træknop
1046233
35.3521.220
168
90
60
* UPK-S-M-100, messing, med træknop
1046234
35.3521.216
138
72
50
* UPK-S-M-125, messing, med træknop
1046235
35.3521.226
168
90
60
H
* Varmebestandigt op til 200°C. Ved brug af saunaarmaturet, brug altid kraven i emballagen. /
Tallerkenventiler (naturlig ventilation)
0
0
Tilslutningsdiameter og model
Uponor nr.
VVS nr.
D
D1
H
ULV-100
1046236
35.35211.10
138
72
58
ULV-125
1046237
35.3522.120
168
90
66
/
10
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Armaturer og ventiler
Standardfarve: Hvid.
Friskluftsriste Tilslutningsdiameter og model
Uponor nr.
VVS nr.
A
D
H
USS-100 med insektnet
1046238
35.3525.110
143
123
57
USS-125 med insektnet
1046239
35.3525.120
143
123
57
USS-160 med aftagelig netkassette
1046240
35.3525.160
235
160
74
USS-200 med aftagelig netkassette
1046241
35.3525.200
235
200
74
160/200 Netkassette til friskluftrist
1046242
35.3525.620
Uponor nr.
VVS nr.
1046243
35.3523.100
Uponor nr.
VVS nr.
UKS-100, vĂŚgmonteret
1046244
35.3523.200
UKTL-100, ventilationshul
1046245
35.3523.300
Uponor nr.
VVS nr.
1046246
35.3523.618
Friskluftsarmatur
1
1 2
1
Tilslutningsdiameter og model
URS-100
Friskluftsarmatur til ventilationshul 2
1
1
1
Tilslutningsdiameter og model
Spalteventil 3
Tilslutningsdiameter og model
4
3
URV-18, 18 x 245 x 340
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
11
Konstruktion af ventilationssystem Definitioner - Friskluftkanalen tilfører frisk udeluft til ventilatoren. - Indblæsningskanalerne fordeler den friske luft fra ventilationsenheden til rummene. - Udsugningskanalerne fører indeluften til ventilationsenheden, som overfører varmen fra udblæsningsluften til at opvarme den indkommende friske luft, om nødvendigt. - Afkastluftkanalen overfører udblæsningsluften fra ventilationsenheden til udblæsningsrøret på taget. - Mineraluld refererer til både glasuld og stenuld (fx Rockwool). Mineraluld kan hverken brænde eller rådne. Ved design af luftkanalerne og dimensionering af kanalerne anbefales det som udgangspunkt at bruge en relativt lav lufthastighed (under 3 m/s) i kanalerne. Anvendelser for Uponor ventilationskanaler Uponor ventilationskanaler bruges i overensstemmelse med kapitel 6.3.1 i det danske bygningsreglement til individuel ventilation af beboelsesbygninger og andre bygninger end beboelsesbygninger.. Køkken emhætte / emfang med ekstern ventilator Udsugningskanalerne fra køkkenventilatorer og emhætter tilsluttes ikke til ventilationssystem, men føres ud til taget separat og har sin egen udsugningsventilator. Placering af kanaler Indblæsnings- og udsugnings-kanalerne installeres normalt - Nede i loftsisoleringen over loftet - I loftsrummene - Inde i gulv/loftsadskillelser - Over et forsænket loft, eller - Under loftet i huset. Indblæsningsarmaturerne installeres især i opholdsrum og soverum for at tilføre frisk udeluft. Fordi udsugningsarmaturerne er konstrueret til affugtning og fjernelse af dårlige
12
lugt i tillæg til luftcirkulation, anbringes de i baderum, saunaer, og nytterum (fyrrum, hobbyrum, bryggers), skabsrum, køkkener og toiletter. Den brugte luft flyder gennem døråbninger fra rummene med indblæsning til rummene med udsugning. Myndighedernes bestemmelser I designet af luftkanalerne og deres installation skal regler og instruktionerne, der står i det danske bygningsreglement kapitel 6 overholdes. Ventilationskanalerne skal beskyttes af et nedhængt loft eller konstruktion mod opholdsrum.. Isolering af kanalerne Forholdene vedr. opvarmning, kondens og brandisolering af kanalerne er specificeret i ventilationsplanen. Isolering kan vises på tegningerne fx med følgende markeringer: - HI1: Varmeisolering, mineraluld 50 mm uden overfladeafslutning. - HI2: Varmeisolering, mineraluld 50 + 50 mm uden overfladeafslutning. - HI2: Varmeisolering, mineraluld 50 mm uden overfladeafslutning + indblæst løs isolering eller tilsvarende mindst 100 mm oven på den isolerede kanal. - HI4: I opvarmede områder isolering mod varme og kondens med ekspanderet polystyren 15 mm. Inde i den øverste loftsplades isolering: Mindst 100 mm løst indblæst mineraluld oven på kanalerne, der er isoleret med 15 mm ekspanderet polystyren. - HI5: Isolering mod varme og kondens med ekspanderet polystyren 15 mm + mineraluld 50 mm uden overfladeafslutning.
Ventilation af saunarum Ved design af kanaler til saunaer skal temperaturbegrænsningerne overholdes. Kanalerne skal enten indsættes i saunaens isolering eller installeret over isoleringen. I andre tilfælde, fx hvor den skal anbringes direkte bag panelerne, skal rørene isoleres termisk. Kanalerne og rammerne til de loftsmonterede armaturer skal fastgøres til loftsstrukturerne på forsvarlig vis med skruer. Bemærk venligst: Brug kun anbefalede varmebestandige saunaarmaturer ved loftet i saunaer. Indblæsningsarmaturerne er markeret med en rød etiket, og udsugningsarmaturerne har en træknop. Saunaarmaturer skal altid installeres i en armaturkrave. Armaturkraven skal fastgøres til saunaloftets træ med skruer, hvorefter saunaarmaturet indsættes. Undgå at installere saunaarmaturet lige over saunaens ovn.
0,5—1,0 m/s
Tilluft fra taget i nærheden Tuloilma katosta kiukaan af ventilationsaggregatet l heisyydest
PoistoFraluft ilma lattian ved lgulv helt
Ventilation af saunarum
Uanset ovenstående forslag skal ventilationsrør som minimum isoleres mod energitab jf. DS 452, klasse 1. Brugen af præ-isolerede indendørs luftprodukter letter isoleringsarbejdet, især på vanskeligt tilgængelige steder.
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Eksempel på ventilationssystem design for et fritliggende hus. Materialelisten findes på næste side.
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
13
UNDERTAGSNIVEAU
UDHUS
VÆRELSE
VÆRELSE LYDDÆMPER
EMHÆTTE
KØKKEN
VENTILATIONSREGULATOR
Ø160 TIL TAGET +AFKASTHÆTTE
REGULATOR FOR PEISAVTREKK
STUE
LYDDÆMPER
BRYGGERS
KLÆDESKAB
TERRASSE
VÆRELSE
FRALUFTVENTIL MONTERES 400 MM OVER GULV, REKTANGULÆR KANAL I VÆGGEN 40 X 140
(UDEN INSEKTNET) SAUNA FUGTSENSOR
Materialeliste for ventilationsplan for et een-familiehus som det vist på forrige side
Tillægsliste over produkter, der ikke findes i Uponors produktsortiment
Uponor nr
Størrelse /kode
Produkt
Producent
stk
m
1046158 1046157 1046195 1046194 1046202 1046201 1046206 1046191 1046190 1046209 1046208 1046211 1046251 1046271 1046213 1046237 1046241 1046239 1046253 1046255
Ø 160 Ø 125 Ø 160 Ø 125 Ø 160/125 Ø 125/125 Ø 160/160 Ø 160 Ø 125 Ø 125/160 Ø 125 Ø 125/160 Ø 125 UTK-125 UPK-125 ULV-125 USS-200 USS-125 USI-125-300 USI-125-1000
Kanal, præ-isoleret Kanal, præ-isoleret Bøjning 90°, præ-isoleret Bøjning 90°, præ-isoleret T-stykke, præ-isoleret T-stykke, præ-isoleret T-stykke, præ-isoleret Samlenippel, præ-isoleret Samlenippel, præ-isoleret Prop, præ-isoleret Prop, præ-isoleret Reduktion, præ-isoleret Dampspærre gennemføring Indblæsningsarmatur Udsugningsarmatur Tallerkenventil Friskluftrist m/aftagelig netkassette Friskluftrist m/insektnet Lyddæmper Lyddæmper
Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor Uponor
13 18 3 12 11 12 1 8 9 1 8 2 21 8 9 4 2 4 3 2
36 48
Størrelse /kode
40x140 Ø 160 Ø 160 Ø 200
Produkt
Producent
Mineraluld isolering 50 mm Rektangulær kanalpakke for badstue Taggennemføring med hætte og inddækning for afkastluft Tallerkenventil Tallerkenventil
stk
m2
7 1 2 1 1
Bemærk at der ikke indgår produkter til emhætte/emfang i ovenstående materialeliste.
14
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Bøjninger 100/45°, 100/90°, 125/45°, 2x125/45°,
Dimensionering af kanaler og lyddĂŚmpere
Kanaler ø 100, ø 125, ø 160 og ø 200 " + 1 4 1 4 1 3 & 1
125/90°, 160/45° og 160/90°
Hoved indblÌsnings- og udsugnings-kanalerne skal sü vidt muligt vÌre store (ø 160) for at mindske tryktabet i kanalerne mest muligt. IndblÌsningsarmaturerne skal tilsluttes til hovedkanalen med forgreninger.
1
1
1 3
! ' 1 ! '
! '
42
og Tryktab, Pa
Tryktab, Pa -,+ *4 5 !6
3 ! ' 2 3
! '
43 4 4
! '
4 4
4
3 2 '6 %! % + '+ 5 ! Luftstrøm (l/s)
Luftstrøm l/s
Reduktionsstykke: Reduktionsstykker 200/160, $ % ; 9 ' ' 3 & % & ' 3 160/200
$ % ; 9 ' #' 4 3 4 Reduktionsstykke: Reduktionsstykker 125/100, & % & #' & 3 160/125, 100/125 og 125/160
",) , 7 & 8 7 Bøjning 200/45° og 200/90°
%! - )' 4 #< ! Luft massefylde 1,20 kg/mÂł
8 2
3
8 7
3
3
: & ' Ekspansion 9 ' ' Reduktion
7
: & ' Ekspansion 3
9 ' ' Reduktion
9 ' ' Reduktion 3
3
2 3
-,+ *4 Tryktab, Pa
Tryktab, Pa -,+ *4
-,+ *4 Tryktab, Pa
2 3
2 3
: & ' Ekspansion
3
3 2 %! % + '+ 5 ! Luftstrøm (l/s) '6
80
3
70
2
40 30 20 10 V1 m/s 2 4
-20
3 1
30 20 3
! '
8 2 3
-50 -60 10 0
10 20 30 40 50 60 70 80 90 100 110 120 130 Ilman tilavuusvirta haarakanavassa [dm3/s] Luftstrøm i kanalgrenen q q(l/s) 3
3
40
2
2
6
3 2 %! % + '+ 5 ! '6
50
1-2
" # '9 Î&#x201D;p ( O9 5 6 Total trykdifferens 1-3, (Pa) (
50
8
T-stykke T-kappale100/100 100/100 Poisto sivulta. Kokonaispaine-ero Î&#x201D;p1-2 Side udsugning Total trykdifferens Î&#x201D;p 1-2
-30
Luftstrøm (l/s)
60
TotalKokonaispaine-ero trykdifferens Î&#x201D;pÎ&#x201D;p , (Pa) [Pa] 1-31-3
3
T-stykke (# 99 % 100/100 % ' + %% Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p ( 1-3 8 2
-40
%! % + '+ 5 ! '6 Luftstrøm (l/s)
100 90
-10
T-kappale100/100 100/100 T-stykke Poisto sivulta. Kokonaispaine-ero Î&#x201D;p1-3 Side udsugning Total trykdifferens Î&#x201D;p 1-3
0
Total trykdifferens Î&#x201D;p1-2Î&#x201D;p , (Pa) Kokonaispaine-ero [Pa]
10
10 9 8 7 6 5 4
8
6
3 2 4
1 0,9 0,8 0,7 0,6 0,5 0,4 0,3
V1 m/s
3 2
0,2
1
2
0,1
3
2 8
%! % + '+ - # + '' N 5 ! '6 Luftstrøm i kanalgrenen q (l/s)
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
3
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Ilman Luftstrøm tilavuusvirta haarakanavassa q2 [dm3/s] i kanalgrenen q (l/s)
2
15
T-stykke (# 99 % 100/100 % ' + %% Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p ( 1-3
T-stykke (# 99 %125/100 ' ' + % Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p1-3 (
8
2
(# 99 % T-stykke 125/100 ' ' + % Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p1-2 (
3
2
! '
3
" # '9 Î&#x201D;p( 1-2
O9 5 6 Total trykdifferens , (Pa) (
(
Total trykdifferens , (Pa)5 6 " # '9 Î&#x201D;p( 1-3
O9
Total" # '9 trykdifferens( O9 Î&#x201D;p1-2 ( , (Pa) 5 6
! '
3 2 (
(
(
4
3 2 8 %! % + '+ - # + '' N 5 ! '6
3 2 8
%! % + '+ - # + '' N 5 ! '6
Luftstrøm i kanalgrenen q3 (l/s)
100
3
90
2
80
Total trykdifferens , (Pa) " # '9 Î&#x201D;p( 1-3
O9 5 6 (
3
+ 5! '6
2 3
60
! '
2 3
(
50 40 30 20 10 0 -10 -20
-40
(
2
v1 [m/s]
2 4 6
-30
1
70
2
TotalKokonaispaine-ero trykdifferens Î&#x201D;p1-3Î&#x201D;p , (Pa) 1â&#x20AC;&#x201C;3 [Pa]
3
T-kappale 125/125 T-stykke 125/125 Poisto sivulta.Total Kokonaispaine-ero Side udsugning trykdifferens Î&#x201D;p1-3Î&#x201D;p1â&#x20AC;&#x201C;3
(# 99 % 125/100 T-stykke % ' + %% Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p ( 1-3
Total" # '9 trykdifferens Î&#x201D;p( 1-3 , (Pa)
O9 S 5 6
Luftstrøm i kanalgrenen q3 (l/s)
Luftstrøm i kanalgrenen q2 (l/s)
50 40 30
8
-50 -60
3 2 8 %! % + '+ - # + '' N Luftstrøm i kanalgrenen q3 (l/s) 5 ! '6
3 2 8
10 0
%! % + '+ - # + '' N 5 ! '6
10 20 30 40 50 60 70 80 90 100 110 120 130
Luftstrøm i kanalgrenen q3 (l/s)
Luftstrøm i kanalgrenen q2 (l/s)
T-stykke 125/125 T-kappale 125/125 Poisto sivulta.Total Kokonaispaine-ero Side udsugning trykdifferens Î&#x201D;p1-2Î&#x201D;p1â&#x20AC;&#x201C;2
(# 99 % T-stykke 125/125 % ' + %% Q " # '9 ( Î&#x201D;pO9 S Side indblĂŚsning Total trykdifferens
T-stykke 125/125 Side indsugning Total trykdifferens Î&#x201D;p1-3
1-2
100 80
10 8
2 v1 [m/s]
6 4
3 2
Total trykdifferens Î&#x201D;p1-3, (Pa)
10 8 6 5 4 3
8 6
20
1
2
v1 [m/s]
4
10 8
6 5 4
3 2
1
2
30
3
0,2
10
60 50 40
5 6 " # '9 ( O9 Total trykdifferens Î&#x201D;p1-2 S , (Pa)
20
Total trykdifferens Î&#x201D;p1-2, Î&#x201D;p (Pa) Kokonaispaine-ero 1â&#x20AC;&#x201C;2 [Pa]
3 ! '
4
%! % + '+ - # + '' N 5 ! '6
1 0,8 0,6 0,5 0,4 0,3
(
3 2 8
(# 99 % T-stykke 125/100 % ' + %% Q " # '9 ( O9 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-3 S
2
4
(3
(
3
42 43 4 4
(
(
2
2
+ 5! '6
3
2
S 0,1
1 0 10 20 30 40 50 60 70 80 90 100 120 140150 3 Ilman tilavuusvirta 2 [dm /s] Luftstrøm irunkokanavassa kanalgrenen q2 q(l/s)
16
0
10 20 30 40 50 60 70 80 90 100 110 120 130 Ilman tilavuusvirta q3 [dm3/s] Luftstrøm i haarakanavassa kanalgrenen q3 (l/s)
S 3 2 8 %! % + '+ # # + '' N Luftstrøm i kanalgrenen q2 (l/s) 5 ! '6
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
(# 99 % 3 T-stykke 160/100 ' ' + % Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p S 1-3
T-stykke (# 99 %160/100 3 ' ' + % Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p1-2 (
(# 99 % 3 T-stykke 160/100 % ' + %%
O9 Side indblĂŚsningQ " # '9 Total trykdifferens( Î&#x201D;p 1-3 S
8 2
2
(
(
( (
+ 5! '6
3 2
2
3
3
Total trykdifferens Î&#x201D;p1-3 (Pa) S 5 6 " # '9 ( , O9
5 6
2
(
Total trykdifferens Î&#x201D;p1-2 , (Pa) " # '9 ( O9
O9 Total" # '9 trykdifferens Î&#x201D;p( 1-3 , (Pa) S 5 6
3
! '
48 42 4 43 4 4
3
2
3
+ 5! '6
2 3
4
4
(
3 2 8 3 2 8
3 2 8 Luftstrøm i kanalgrenen q3 (l/s) 5 ! '6 %! % + '+ - # + '' N
(# 99 % 3 T-stykke 160/100 % ' + %% Q " # '9 ( Side indblĂŚsning Total trykdifferens Î&#x201D;p O9 S
%! % + '+ - # + '' N 5 ! '6
Luftstrøm i kanalgrenen q2 (l/s)
2
2
+ 5! '6
3
Total trykdifferens Î&#x201D;p1-3, (Pa)
2
3
3
8
Total trykdifferens Î&#x201D;p1-2, (Pa)
+ 5! '6
S
S S
S
T-stykke 160/125 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-3
3
+ 5! '6
3 2 8 %! % + '+ - # + '' N 5 ! '6 Luftstrøm i kanalgrenen q3 (l/s)
3
2 3 2
Luftstrøm i kanalgrenen q2 (l/s)
T-stykke 160/160 Side udsugning Total trykdifferens Î&#x201D;p1-3
8 2
3
+ 5! '6
2
8 2 3 + 5! '6
Luftstrøm i kanalgrenen q3 (l/s)
3 8 7 + 5! '6
S S 3 S
3
2
S S
S 3 2 8
3
Total trykdifferens Î&#x201D;p1-3 ( , (Pa) " # '9 ( O 5 6
2
3
Total trykdifferens Î&#x201D;p1-2 9 9 , (Pa)
6
2
3
2
Total trykdifferens Î&#x201D;p1-3,9(Pa) 9 5
T-stykke 160/125 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-2
2
2
S
S 3 2 8 3 2 %! % + '+ # # + '' N 5 ! '6 Luftstrøm i kanalgrenen q2 (l/s)
3
S
3
3 2 8 %! % + '+ - # + '' N Luftstrøm i kanalgrenen q3 (l/s) 5 ! '6
T-stykke 160/125 Side udsugning Total trykdifferens Î&#x201D;p1-2
T-stykke 160/125 Side udsugning Total trykdifferens Î&#x201D;p1-3
1-2
Total trykdifferens Î&#x201D;p1-2 , (Pa) S 5 6 " # '9 ( O9
4
(3
3
2 3 2
Luftstrøm i kanalgrenen q2 (l/s)
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
2
S3
3
2 3 2
Luftstrøm i kanalgrenen q3 (l/s)
17
(# 99 %160/160 3 3 T-stykke ' ' + % Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p S 1-2
(# 99 %160/160 3 3 T-stykke % ' + %% Q " # '9 ( O9 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-3 S
2
2 3
3 8 7 + 5! '6
42 43 4 4 4
3
Total trykdifferens Î&#x201D;p1-3 ( , (Pa) " # '9 ( O 5 6
2 3
2
3
2
3 2 3 2 %! % + '+ # # + '' N Luftstrøm i kanalgrenen q2 (l/s) 5 ! '6
(# 99 % 3 T-stykke 200/160 ' ' + % Q " # '9 Side udsugning Total trykdifferens (Î&#x201D;p O9 S
S
S
2
3 2 3 2 Luftstrøm i kanalgrenen q3 (l/s) %! % + '+ - # + '' N 5 ! '6
2
(
(
+ 5! '6
42 43 4 4 4
3
(
2 ( (
2
3 3 8 7 + 5! '6
4
Total " # '9 trykdifferens Î&#x201D;p(1-3 , (Pa)
O9 S 5 6
2 3
Total trykdifferens Î&#x201D;p1-2 (Pa) ( 5 6 " # '9 ( , O
" # '9 ( O9 Total trykdifferens Î&#x201D;p1-3 , (Pa) S 5 6
3
3 2 3 2 %! % + '+ # # + '' N Luftstrøm i kanalgrenen q2 (l/s) 5 ! '6
T-stykke 200/160 (# 99 % 3 % ' + %% Q " # '9 ( O9 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-3 S
8
(# 99 %200/160 3 T-stykke ' ' + % Q " # '9 ( O9 Side udsugning Total trykdifferens Î&#x201D;p S 1-2
1-3
3
2
4
+ 5! '6
4
+ 5! '6
3
" # '9
O 5 6 Total trykdifferens( Î&#x201D;p (Pa) 1-2, (
Total" # '9 trykdifferens Î&#x201D;p( 1-2 , (Pa)
O ( 5 6
(# 99 %160/160 3 3 T-stykke % ' + %% Q " # '9 ( O9 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-2 S
3
2 3
+ 5! '6
2 3
(3 3 2 8 3 Luftstrøm i kanalgrenen q3 (l/s) 5 ! '6 %! % + '+ - # + '' N
T-stykke 200/160 (# 99 % 3 Side indblĂŚsning Total trykdifferens Î&#x201D;p1-2 S % ' + %% Q " # '9 ( O9
4 3 2 3 2 3 %! % + '+ # # + '' N 5 ! '6 Luftstrøm i kanalgrenen q2 (l/s)
3 2 8 %! % + '+ - # + '' N Luftstrøm i kanalgrenen q3 (l/s) 5 ! '6
Total trykdifferens Î&#x201D;p1-2 , (Pa) ( 5 6 " # '9 ( O
+ 5! '6
2
3
S
S 3 2 3 2 3 2 %! % + '+ # # + '' N 5 ! '6 Luftstrøm i kanalgrenen q2 (l/s)
18
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Lyddæmpernes lyddæmpning pr. oktav, ISO 7235:2003 STØJREDUKTION ΔL (dB) Oktavbånd centerfrekvens (Hz) Mål
63
125
250
500
1000
2000
4000
8000
125x300
2,0
6,5
9,5
15,5
11,0
7,5
8,0
6,0
125x650
5,0
14,5
15,5
23,5
33,0
24,5
22,0
15,5
125x1000
10,5
18,0
20,5
29,0
37,0
36,0
36,5
26,5
160x650
6,0
12,5
12,0
21,0
29,5
18,0
14,5
11,5
160x1000
10,5
17,0
16,0
25,0
30,5
27,5
23,0
16,5
Lyddæmperens tryktab, ISO 7235:2003 125x300
1
2
3
4
5
qVD / l/s
43,7
51,4
65,4
77,5
100,4
Val / m/s
3,6
4,2
5,3
6,3
8,2
PtD / Pa
2,5
3,5
5,6
7,9
13,2
ζτ / −
0,32
0,33
0,33
0,33
0,33
125x650
1
2
3
4
5
qVD / l/s
43,1
49,6
62,4
76,1
93,9
Val / m/s
3,5
4,0
5,1
6,2
7,7
PtD / Pa
5,2
6,9
10,3
15,0
22,3
ζτ / −
0,70
0,71
0,667
0,651
0,634
125x1000
1
2
3
4
5
qVD / l/s
39,4
51,9
66,4
77,5
98,4
Val / m/s
3,2
4,2
5,4
6,3
8,0
PtD / Pa
7,2
12,4
19,3
26,2
40,8
ζτ / −
1,17
1,15
1,10
1,09
1,06
160x650
1
2
3
4
5
qVD / l/s
71,1
86,6
104
127
157
Val / m/s
3,5
4,3
5,2
6,3
7,8
PtD / Pa
5,2
7,9
11,1
16,4
25,2
ζτ / −
0,70
0,71
0,696
0,686
0,689
160x1000
1
2
3
4
5
qVD / l/s
74,1
95,2
116
144
180
Val / m/s
3,7
4,7
5,8
7,2
8,9
PtD / Pa
9,2
15,0
22,6
34,8
55,4
ζτ / −
1,13
1,11
1,13
1,13
1,15
qVD Val PtD ζτ
= = = =
Luftstrøm, l/s Lufthastighed, m/s Totalt tryktab for luft, Pa Total tryk træk koefficient, −
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
19
Lyddæmpernes tryktab, ISO 7235:2003 USI-125-300, USI-125-650 og USI-125-1000
Totalt tryk, Pa
Kanal lufthastighed, m/s
Luftstrøm, l/s Luft massefylde 1,2 kg/m³
USI-160-650 og USI-160-1000
Totalt tryk, Pa
Kana lufthastighed, m/s
Luftstrøm, l/s Luft massefylde 1,2 kg/m³
20
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Installation Oversigt Uponors ventilationskanaler og -komponenter er lavet af polypropylen plast. De har derfor lille vægt og er lette at håndtere. Kanalinstallationen må ikke udsættes for temperaturer under -15°C. Kanalerne må ikke kastes, trækkes, bules eller på anden vis beskadiges. Kanalerne leveres fra fabrikken med begge ender tillukkede og pakket i plastposer og papkasser for har holde dem rene. Kanalerne og komponenterne skal beskyttes ved at holde kanalenderne lukkede og ved at opbevare komponenterne i deres respektive emballager, når de opbevares på arbejdspladsen. De skal beskyttes mod lang tids påvirkning af direkte sollys. Fjern først endelukningen og de beskyttende poser, når de installeres. Åbne ender af præinstallerede kanaler skal beskyttes med endepropper, som skal forblive på plads, indtil armaturerne er installerede og justerede.
Dog skal lodrette sektioner understøttes, så deres vægt ikke hviler på samlestykket. Hvis man ikke kan bruge vinkelbeslag, kan samlingen sikres med 8-10 mm popnitter, hvis det er nødvendigt.
Monter passende anbragte rense lemme i kanalerne for at befordre rensning.
Kanalmontage Skæring og samling af kanaler Uponor kanalerne skal afskæres vinkelret med en fintandet (1-2 mm) sav . Fjern savsmuld fra både de ydre og de indre overflader, og affas de indre kanter af skærefladen for at lette indsættelsen af samlestykkerne. Kanalsamlinger, retningsændringer og forgreninger må kun udføres med kanalkomponenter. Komponenterne er forsynet med pakningsfalse i komponentmaterialet. Kanalerne har ingen false. Udfør samlingen ved at skubbe kanalen ind på samlestykket, indtil det når samlestykkets stopkant. Udfør samlingerne manuelt; komponenterne kan smøres med rent vand eller vand tilsat lidt opvaskemiddel. Samlingerne udføres uden skruer eller nitter.
Skæring og samling af præisolerede kanaler og kanalsektioner Præisolerede kanaler skæres sammen med isoleringen og samles på samme måde som ikke-isolerede kanaler og kanalsektioner. I nogle tilfælde kan det være nødvendigt at fjerne noget af isoleringen. Fx ved gennemføring gennem en dampspærre, skal varmeisoleringen fjernes på den varme side af flangen gennem dampspærren, hvis der ikke er behov for kondensisolering. Tip! Lav et installationsmærke 5 cm fra kanalens åbning. Det sikrer, at røret er skubbet helt ind, og at samlingen er tæt.
Stopkant
Præ-isoleret rør
Læbering
Aluminumsspændbånd
Samlekomponent
Aluminiumsspændbånd Stopkant
Læbering
Præ-isoleret samlekomponent
Ekstra isolering Samlekomponent
Ekstra isolering
Rør
Præ-isoleret prop Præ-isoleret komponent
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Præ-isoleret rør
21
Kanalføring gennem dampspærre Når en kanal skal føres gennem en struktur med en dampspærre (fx et tag), skal gennemføringshullet forsegles med en dampspærre flangepakning. Den ene side af dampspærre flangepakningen er selvklæbende. Flangepakningen installeres normalt over dampspærren, så der er tæt mellem den termiske isolering og dampspærren.
• Rens fugtspærren for støv m.m. Fjern den beskyttende plast fra flangepakningen og tryk den hårdt mod fugtspærren ovenfra/ udefra (A). • Med en skarp kniv, lav en åbning i dampspærren, der svarer til størrelsen af flangepakningens hul (B). Sørg for at flangepakningen er trykket ind mod dampspærren på begge sider. • Skub/træk forsigtigt kanalen gennem flangepakningens hul mens kanalen roteres (C). • Før kanalen ind på sin endelige plads, og forbind den til de øvrige kanaler (D).
1 = Flangepakning 2 = Dampspærre 3 = Kanal
22
Kanalføring af præ-isolerede kanaler gennem dampspærre Ved afskæring af præ-isolerede kanaler, bemærk at isoleringsmaterialet skal skæres et andet sted en den aktuelle kanal. Varmeisoleringen skal slutte på den kolde side af dampspærrens flangepakning. Kanalsektionen på den varme side af dampspærren kan efterlades uisoleret, med mindre kanalerne kræver installation af kondensisolering. På den varme side af dampspærren, fx i et forsænket loft, skal indblæsningskanalen være polystyren-isoleret, hvis indblæsningsluften er afkølet eller kold, eller hvis luften ikke er forvarmet om vinteren. I dette tilfælde afskær polystyren-isoleringen ved flangepakningen, og forsegl den lufttæt til dampspærrens flangepakning.
1 = Flangepakning 2 = Dampspærre 3 = Kanal
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Understøttelse Understøttelse skal udføres med støtter, der er konstrueret til ventilationskanaler. Den største afstand mellem støtter på vandrette kanaler er 1.500 mm. Der skal (desuden) installeres en støtte ved hver samling/komponent. Lodrette sektioner skal understøttes, så deres vægt ikke hviler på samlestykket. Også skråtstillede kanaler skal understøttes for at hindre bevægelser under installationen af armaturer eller ved rengøringen af kanaler/armaturer. Støtterne kan fx monteres på støttepælen under kanalen. Kanalerne skal også fastgøres øverst på loftsstrukturen for at hindre det i at flytte sig under rengøring. Understøttelse af præ-isolerede kanaler Præ-isolerede kanaler understøttes på nøjagtig samme måde som uisolerede kanaler. Bemærk dog, at isoleringen ikke må skæres ved støttepunktet. I stedet skal støtten placeres udenpå isoleringen. I dette tilfælde skal der benyttes støtter med en større diameter.
Næste støttepunkt max. 1500 mm
1 = Støtte ved nedre tagafstivning 2 = Isoleret (50 mm) kanal 3 = T-stykke 4 = Støttepæl (hvis støtten ikke er monteret på tag afstivningen) 5 = Støtte
1 2 3 4
= = = =
Kanal Støtte Nedre tagafstivning Nedsænket loft
Eksempel på understøttelse af en kanal over et forsænket loft.
Eksempel på understøttelse af en loftsmonteret kanal og et T-stykke.
1 2 3 4
= = = =
Kanal + termisk isolering Støtte Nedre tagafstivning Nedsænket loft
Eksempel på understøttelse af en kanal over et forsænket loft.
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
1 = Kanal + termisk isolering LE5 (15+50) 2 = Støtte 3 = Støtte ved øvre tagafstivning Eksempel på understøttelse af en isoleret kanal på et loft. Mellemrum mellem støtter maks. 1.500 mm.
23
Isolering Isoleringens tykkelse er specificeret i ventilationsplanen. Normale isoleringstykkelser er som følger: Varme rum (indenfor dampspærren): • Indblæsnings og udsugnings luftkanaler har ikke behov for isolering undtagen kanaler inde i saunalofter, som skal termisk isoleres med 50 mm mineraluld uden overfladeafslutning. Hvis indblæsningsluften kan være afkølet, skal indblæsningsluftkanalerne være isoleret med ekspanderet PE plast. Hvis indblæsningsluften ikke er forvarmet om vinteren, skal kanalerne være isoleret med ekspanderet PEplast. • Udendørs og afkastluftkanaler skal installeres med ekspanderet PE plast isolering, der fungerer som kondensisolering. Uopvarmede områder (udenfor dampspærren) • Indsugnings- og afkastluftkanaler samt friskluft- og udsugningskanaler, som er anbragt indenfor den yderste tagisolering, hvor der er mindst 100 mm løst mineraluldsfyld, skal kondens- og varmeisoleres med 15 mm ekspanderet polystyren. Bemærk, at i dette tilfælde skal indblæst mineraluld være anbragt i den øverste del af tagkonstruktionen.
• Alternativt skal der bruges 50 mm mineraluld uden overfladeafslutning som kanalisolering af udsugnings-, indsugnings- og afkast-kanaler, som er anbragt indenfor den yderste tag-varmeisolering, hvor der er mindst 100 mm indblæst løs isolering. • Indsugnings- og afkast-luftarmaturer, der er placeret over den yderste loftsisolering, skal varmeisoleres med 15 mm ekspanderet polystyren + 50 mm mineraluld uden overfladeafslutning eller 50 + 50 mm mineraluld uden overfladeafslutning. • Udsugnings-luftarmaturer, der er placeret over den yderste loftsisolering, kan varmeisoleres med 50 mm mineraluld uden overfladeafslutning.
Kondensisoleringen af kanalerne er implementeret med 15 mm ekspanderet PE plast, som er ført ind over kanalen. Isoleringen kan også være åbnet lodret, viklet rundt om kanalen og samlet med limning. Luk de tværgående og lodrette samlinger tæt med kontaktlim. Isoleringen af præ-isolerede kanaler er tæt, når enden af den præ-isolerede kanal med intern samling er forbundet meden anden intern samling. Samlingens tæthed sikres med to aluminiumsspændbånd. Præisolerede samlinger, kanaler og sektioner er installeret korrekt når de præ-isolerede kanaler er skubbet ind, indtil det når stopkanten. Samlingens tæthed sikres med et aluminiumsspændbånd.
• Friskluftsarmaturer, der er placeret over den yderste loftsisolering, kan varmeisoleres med 50 mm mineraluld uden overfladeafslutning. Når man isolerer kanaler på kolde steder indenfor loftets termiske isolering med ekspanderet PE plast, skal loftets termiske isolering være altid være baseret på mineraluld. Men hvis den termiske isolering af kanalerne er med mineraluld, må loftet være isoleret med et vilkårligt lovligt isoleringsmateriale på markedet. Isoleringen er svøbt tæt rund om kanalerne og fastgjort med ståltråd, strips eller lignende.
24
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Kanaler i et varmt rum, i nedsænket loft eller i en kasse Lufttemperaturen i kanalen er over + 10 grader
Kanaler i kolde rum (loft, forsænket loftisolering eller over den) • Luftforsyningskanal • Udeluft til ventilationsenhed • Udsugningskanal • Udsugningsluft fra ventilationsenhed
• Udsugningskanal • Luftforsyningskanal Ingen isolering Dampspærre Lufttemperaturen i kanalen er under + 10 grader
Dampspærre
Dampspærre
• Udeluftkanal til ventilationsenhed • Udsugningskanal fra ventilationsenhed • Luftforsyningskanal Dampspærre
Dampspærre
15 mm ekspanderet isolering LE4
Tagbjælke Dampspærre
Tagbjælke Dampspærre
Kanaler i løs mineraluld eller tilsvarende Isoleringsmaterialet er PE ekspanderet polystyren LE 4 eller 50 mm mineraluld uden overfladeafslutning LE3.
Dampspærre
I et koldt rum over loftsisoleringen er kanalerne isoleret med 15 mm ekspanderet polystyren + 50 mm mineraluld uden overfladeafslutning LE5 eller 50 + 50 mm mineraluld uden overfladeafslutning LE2.
Kanal isoleringsmuligheder
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
25
Installation og indstilling af luftarmaturer Oversigt Installer og indstil først armaturerne efter den afsluttende rengøring af arbejdspladsen.
Ventilationssystemet må først tages i brug, når bygningen er helt færdig.
Uponors ventilationssystemarmaturer er klar til brug som indblæsnings- eller udsugningsarmaturer med Uponor kanaler.
Tilslutning af luftarmaturer til kanalerne 1 = Kanal 2 = Dampspærre flangepakning
A.
3
3 = Kanalsektion til afskæring 4 = Det endelige loft
B.
3
5 = Armatur 6 = Monteringsskrue
C.
A. Afskær kanalen til niveauet for det endelige loft med en fintandet sav eller end kanal skæretang. Fastgør kanalen indefra med to monteringsskruer.
B. Indsæt armaturet i kanalen. Armaturet låser selv til kanalen, og montageproceduren er færdig. Bemærk venligst: Hvis det loftsmonterede armatur er monteret på en komponent i stedet for en kanal, skal kanalpakningen skæres tættere på langs den punkterede linje med en saks eller en skarp kniv.
D. Det loftsmonterede armaturs (ø 125) krave er en ophøjet ring, som fører den udgående luft gennem loftet. Dette forhindrer støv i indeluften i at komme op, og det holder loftet rent. Den ophøjede krave er velegnet til både nye bygninger og renovering.
len, så kraven tætter mellem ventilen og loftet.
3
C. Indblæsnings- og udsugningsarmaturer er i saunaer for loftsmontage er forsynet med monteringsrammer, der skal fastgøres til loftsstrukturen med skruer. Installer armaturet i rammen ved at dreje det. Loftsmonterede rammer, der er installeret over saunaovnen, skal altid være sikret med skruer.
Hvis kanalen er afskåret til overfladens niveau, skal kanalen forlænges. Skær kanalpakningen tættere på langs den punkterede linje, og installer armaturet og kraven som angivet i trin B.
Udvidelse
Krave
Installation af kraven Afskær kanalen 50 mm under loftets underside. Installer kraven på ventilen. Skub ventilen op på kana-
E. Installer det vægmonterede armatur ved at skubbe det ind i kanalen, som er afskåret i niveau med væggens overflade. Armaturets dæksel kan fjernes ved at vride det af med en skruetrækker. Basispladen er forsynet med huller til monteringsskruerne.
26
Diameter 125 Produktkode 1046218
Armatur
Fastgørelseshuller " )' ,
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Friskluftrist Friskluftsristene er forsynet med let udtagelig netkassette eller insektnet. Netkassetten skal renses regelmæssigt, op til én gang om måneden på de varme årstider (april-oktober). Behovet for rensning kan variere stærkt afhængig af bygningens placering.
Det hvide ABS plastgitter kan males med fx sprøjtemaling, og grunding er normalt ikke nødvendig. Kontroller altid først, om malingen kan bruges på ABS plast. Før malingen, rens overfladen med fx acetone.
Friskluftsventil til vægmontage (udendørs luftarmatur med filter i ventilation med mekanisk udblæsning) Armaturet installeres i et hul, ø 106 mm, boret eller udsavet over vinduet. Armaturet åbnes og lukkes med træksnoren. Installation Åbn det indvendige armatur med træksnoren, og skru dækslet af. Roter friskluftristen lidt mod uret, og træk det af. Afkort kanalforlængelsen, så den passer til murens tykkel-
se. Installer kanalen og selve armaturet, og fastgør dem med skruer. Skru friskluftristen og dækslet på igen, og juster armaturåbningen. Fastgør friskluftristens holder med skruer. Installer friskluftristen ved at presse det ind på friskluftristens holder. Vedligeholdelse Rens filteret to gange om året med varmt vand.
Friskluftsventil til ventilationshul (udendørs luftarmatur med filter i ventilation med mekanisk udblæsning) Installer armaturet i et hul, ø 106 mm, boret eller udsavet over ventilhullet. Installation Åbn den indvendige ventil med træksnoren, og skru dækslet af. Roter friskluftristen lidt mod uret, og træk det af. Installer selve armaturet og det løse bunddæksel med skruer. Hvis muren ved ventilhullet er over 90 mm tyk, forlæng armaturet med den medleverede forhøjelsesring.
Skru friskluftristen og dækslet på igen, og juster armaturåbningen ved at dreje dækslet. Luftføring Luftføringen kan rettes opad, mod venstre eller mod højre. Hvis der fx er en radiator til venstre rettes luftføringen mod venstre. Luftføringen kan trækkes ud for at drejes ved først at åbne armaturet ved træksnoren og derpå skrue dækslet af. Vedligeholdelse Rens filteret to gange om året med varmt vand.
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
27
Spalteventil
Vedligeholdelse
(Friskluftventil med ďŹ lter til luftindtag ved mekanisk ventilation med afkast.) Installer armaturet enten i en 19 x 250 mm spalte i toppen af vinduesrammen eller mellem vinduesrammen og muren. Hvis spalteventilen er monteret over en radiator, skal den indre kant vende opad og den ydre kant vende nedad.
Rens ďŹ lteret to gange om ĂĽret med varmt vand. TrĂŚk ďŹ lteret i armaturets rørsektion ud, efter at lukkelamellerne er fjernet ved at løsne de to monteringsskruer.
Friskluftsventil (Friskluftventil med ďŹ lter til luftindtag ved mekanisk ventilation med afkast.) Armaturet installeres i et hul, ø 106 mm, boret eller udsavet midt over vinduet.
Justering af armaturer TrykmĂĽling ! '
Juster armaturerne som vist i justeringskurverne pü side 24-25 ved at rotere armaturskiven (loftsmonterede armaturer) eller ved at übne nogle rÌkker huller (vÌgmonterede armaturer). Trykdifferensen müles pü de punkter, der er vist pü de tilhørende tegninger. Efter justeringen lüs armaturernes position med lüseskruerne. Et manometer kan ogsü bruges til at justere og kontrollere justeringen af armaturerne. I dette tilfÌlde er armaturets lukkede tilstand, dvs. armaturets 0-niveau, følgende: - LuftindblÌsning, loft, ø 125: +10 mm - LuftindblÌsning, loft, ø 100: +10 mm - Luftudsugning, loft, ø 125: -3 mm - Luftudsugning, loft, ø 100: -1 mm - Saunaarmatur, loft, ø 125: +8 mm
28
Lukkelameller %# '
Manometer !
Armaturerne prÌ-justeres før den endelige justering og müling. De prÌ-justerede vÌrdier ved et tryktab over armaturet pü 20 Pa ses i tabellerne pü nÌste side. Efter installationen af luftindblÌsningsarmaturerne, kan lukkelamellerne fjernes fra rammen med en skarp kniv.
- MĂĽl trykdifferensen pĂĽ punkterne vist i tegningen. - Juster ved at rotere ventilspindlen, stigning 1 mm/omdrejning. - 0-niveau = lukket armatur. - Sidehuller ĂĽbne/lukkede. - Ă&#x2026;bn det nødvendige antal huller med en saks eller kniv. - Geninstaller lukkelamellerne ved at trykke dem pĂĽ plads.
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Tabeller over armatur fabriksindstillinger, trykdifferens 20 Pa Luftindblæsningsarmaturer Indblæsningsluft l/s
Loftmonteret/sauna armaturer 125
Loftmonteret/sauna armaturer 100
Vægmonterede armaturer 100 & 125 Sidehuller åben
Vægmonterede armaturer 100 & 125 Sidehuller lukkede.
Omdrejninger åben
Omdrejninger åben
Rækker af åbne huller
Rækker af lukkede huller
3 4 4 5 5 6 6 7 8 9 10 11
4 4 5 6 6
2 3 3 4 4 5 6 7 8 9 9 10
3 3 4 5 5 6 6 7 8 9 10 10
6 7 8 9 10 11 12 13 14 15 16 17
Udsugningsarmaturer Udsugningsluft Udsugningsarma- Udsugningsarmatur 100 l/s tur 125 Omdr. åben Omdr. åben
3 4 5 6 7 8 9 10
3 4 6 7 8 10 11 13
Udsugningsluft Udsugningsarma- Udsugningsarmatur 100 l/s tur 125 Omdr. åben Omdr. åben
4 6 8 10 12 14 16 18
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
11 12 13 14 15 16 17 18
14 15 16 18 20 22 23 24
20
29
Luftstrøm, trykdifferens og støjniveau
3 8
UW X
3 8
UW X
UW X UW X
UW X
MĂĽlt trykdifferens Pa $ '9 (
MĂĽlt trykdifferens Pa $ '9 (
"Y 4 "Y 43 "Y 4 "Y 4
3 8
Udsugningsarmaturer Ă&#x2DC;100
UW X UW X
UW X
UW X
Udsugningsarmaturer Ă&#x2DC;125
Omdrejninger Justeringsposition mm
MĂĽlt trykdifferens Pa
Omdrejninger Justeringsposition mm
MĂĽlt trykdifferens Pa
Omdrejninger "
#' ,, * ' !! mm Justeringsposition
30
"Y 4
Sauna luftindblĂŚsningsarmaturer Ă&#x2DC;125
"Y 4 "Y 48 "Y 4 "Y 4
"Y 43
"Y 48
Omdrejninger "
#' ,, * ' !! mm Justeringsposition
UW X
Sauna luftindblĂŚsningsarmaturer Ă&#x2DC;100
UW X
"Y 4 "Y 43 "Y 4 "Y 4
UW X UW X
UW X UW X
"Y 4
3 8
"Y 48
UW X
Omdrejninger "
#' ,, * ' !! mm Justeringsposition
"Y 48
"Y 4 "Y 48 "Y 4 "Y 4
"Y 48
LuftindblĂŚsning loftsarmaturer Ă&#x2DC;125
MĂĽlt trykdifferens Pa $ '9 (
MĂĽlt trykdifferens Pa $ '9 (
Omdrejninger "
#' ,, * ' !! mm Justeringsposition
"Y 43
LuftindblĂŚsning loftsarmaturer Ă&#x2DC;100
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Luftstrøm, trykdifferens og støjniveau Luftindblæsning vægarmaturer Ø100 med lukkede sidehuller
Luftindblæsning vægarmaturer Ø125 med lukkede sidehuller Justeringsposition, rækker med åbne huller
Målt trykdifferens Pa
Målt trykdifferens Pa
Justeringsposition, rækker med åbne huller
Luftindblæsning vægarmaturer Ø100 med åbne sidehuller
Luftindblæsning vægarmaturer Ø125 med åbne sidehuller
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
Justeringsposition, rækker med åbne huller
Målt trykdifferens Pa
Målt trykdifferens Pa
Justeringsposition, rækker med åbne huller
31
Luftstrøm og trykdifferens
Friskluftsarmatur ø100
Spalteventil 18x245x340
Uden filter
Trykforskel, Pa
Trykforskel, Pa
Med filter
Målt trykforskel Pa
Målt trykforskel Pa
Målt trykforskel Pa
Friskluftsriste
32
U P O N O R P L A N LÆ G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
BemĂŚrkninger
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
33
BemĂŚrkninger
34
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
BemĂŚrkninger
U P O N O R P L A N LĂ&#x2020; G N I N G S - O G I N S TA L L AT I O N S V E J L E D N I N G 2 0 1 0
35
01.06.2007 SENEWA OY
KAIKKI KANAVAT Uponor Suomi Oy Nastola - Forssa
Uponor A/S Uponor VVS Banemarksvej 2A 2600 Glostrup
T 4326 3400 F 4343 1011 E vvs.dk@uponor.com W www.uponor.dk