Profinet Industrial Ethernet

Page 1

Master: 800653 - ProductGroupID: PG0316 - Layout: PG301 - Umbruch:

Industrial Ethernet PROFInet Type A, Standard and Robust

Type Cable structure

Fixed installation, indoor 2x2x0.64 mm

Heavy duty 2x2x0.64 mm

Inner conductor diameter: Core insulation: Core colours: Stranding element: Shielding 1: Shielding 2: Total shielding: Inner sheath material: Outer sheath material: Cable external diameter: Outer sheath colour:

Copper, bare (AWG 22/1) PE wh, ye, bu, og Star quad Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, tinned PVC PVC approx. 6,5 mm ± 0,2 mm Green similar to RAL 6018

Copper, bare (AWG 22/1) PE wh, ye, bu, og Star quad Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, tinned PVC PUR approx. 6,5 mm ± 0,2 mm Green similar to RAL 6018

100 Ohm ± 15 ohm at 1 to 100 MHz 62,0 Ohm/km max. 0,50 GOhm x km min. 50,0 nF/km nom. 2,0 kV

100 Ohm ± 15 ohm at 1 to 100 MHz 62,0 Ohm/km max. 0,50 GOhm x km min. 50,0 nF/km nom. 2,0 kV

Electrical data Characteristic impedance: Conductor resistance: Insulation resistance: Mutual capacitance: Test voltage:

Typical values Frequency Attenuation Next ACR

(MHz) (dB/100m) (db) (db)

10 5,2 70,0 64,8

16 6,9 65,0 58,1

62,5 15,0 55,0 40,0

100 19,5 50,0 30,5

Technical data Weight: Min. bending radius for laying: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight:

approx. 67,0 kg/km 100,0 mm -40°C +70°C 0,34 MJ/m 32,0 kg/km

approx. 64,0 kg/km 46,0 mm -40°C +70°C 0,91 MJ/m 32,0 kg/km

PROFInet Draft CMG 60°C or PLTC or AWM 20201 CSA FT 4

PROFInet Draft -

Norms Applicable standards: UL Style: CSA standard:

Application These copper data cables, designed especially for heavy-duty industrial applications, are very well suited for Ethernet applications. They ensure superiour transmission properties and can be used even under most severe conditions. The line specified here correspond to the PROFInet type A it is designed for normal (PVC) and robust (PUR) fixed installation applications.

Part no.

800653, PROFInet type A (SK)

Dimensions and specifications may be changed without prior notice.

R 76

801194, PROFInet type A (SK)


Master: 801195 - ProductGroupID: PG0316 - Layout: PG301 - Umbruch:

Industrial Ethernet PROFInet Type A, radiation resistant + armoured

Type Cable structure

ray loaded areas 2x2x0.64 mm

Fixed installation, outdoor 2x2x0.64 mm

Inner conductor diameter: Core insulation 1: Core colours 1: Stranding element: Shielding 1: Shielding 2: Total shielding: Armouring: Inner sheath material: Outer sheath material: Cable external diameter: Outer sheath colour:

Copper, bare (AWG 22/1) XLPE ray cross-linking wh, ye, bu, og Star quad Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, tinned TPR ray cross-linking PUR approx. 6,5 mm ± 0,2 mm Green similar to RAL 6018

Copper, bare (AWG 22/1) PE wh, ye, bu, og Star quad Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, tinned Steel rib PVC PE approx. 9,3 mm ± 0,5 mm Black

100 Ohm ± 15 ohm at 1 to 100 MHz 62,0 Ohm/km max. 0,50 GOhm x km min. 50,0 nF/km nom. 2,0 kV

100 Ohm ± 15 ohm at 1 to 100 MHz 62,0 Ohm/km max. 0,50 GOhm x km min. 50,0 nF/km nom. 2,0 kV

Electrical data Characteristic impedance: Conductor resistance: Insulation resistance: Mutual capacitance: Test voltage:

Typical values Frequency Attenuation Next ACR

(MHz) (dB/100m) (db) (db)

10 5,2 70,0 64,8

16 6,9 65,0 58,1

62,5 15,0 55,0 40,0

100 19,5 50,0 30,5

Technical data Weight: Min. bending radius for laying: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight:

approx. 63,0 kg/km 46,0 mm -40°C +80°C 0,29 MJ/m 32,0 kg/km

approx. 124,0 kg/km 93,0 mm -40°C +70°C 2,14 MJ/m 31,0 kg/km

PROFInet Draft

PROFInet Draft

R

Norms Applicable standards:

Application These copper data cables, designed especially for heavy-duty industrial applications are very well suited for Ethernet applications. They ensure superiour transmission properties and can be used even under most severe conditions. The line specified here correspond to the PROFInet type A and because of the special construction with cross-linked inner-jacket and PUR outer-jacket it is suitable for fixed installation applications inside radiated areas and with the PVC inner-jacket/PE outer-jacket it is suitable for areas with rodent problems.

Part no.

801195, PROFInet type A (SK)

801650, PROFInet type A (SK)

Dimensions and specifications may be changed without prior notice.

R 77


Master: 801651 - ProductGroupID: PG0316 - Layout: PG301 - Umbruch:

Industrial Ethernet PROFInet Typ B hybrid

Type Cable structure

Mobile use 2x2x0,64 mm (stranded)+ 4x1,5qmm

Inner conductor diameter 1: Inner conductor diameter 2: Core insulation 1: Core insulation 2: Core colours 1: Core colours 2: Stranding element 1: Shielding 1: Shielding 2: Total shielding: Outer sheath material: Cable external diameter: Outer sheath colour:

Copper, tinned (AWG 22/7) Copper, bare (AWG 16/84) Foam-skin-PE Foam-skin-PE wh, ye, bu, og Black Double core Polyester foil over stranded bundle Polyester foil, aluminium-lined Polyester foil FRNC approx. 10,3 mm ± 0,3 mm Green similar to RAL 6018

Electrical data Characteristic impedance: Conductor resistance: Insulation resistance: Mutual capacitance: Test voltage:

100 Ohm ± 15 ohm at 1 to 100 MHz 60,0 Ohm/km max. 0,50 GOhm x km min. 52,0 nF/km nom. 2,0 kV

Typical values Frequency Attenuation Next ACR

(MHz) (dB/100m) (db) (db)

10 6,3 50,0 43,7

16 8,0 47,0 39,0

62,5 16,5 38,0 21,5

100 21,3 35,0 13,7

Technical data Weight: Min. bending radius for laying: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight:

approx. 153,00 kg/km 103,0 mm -40°C +70°C 1,50 MJ/m 94,0 kg/km

Norms Applicable standards:

PROFInet Draft

Application This copper data cable, designed especially for heavy-duty industrial applications is very well suited for Ethernet applications. Ir ensures superiour transmission properties and can be used even under most severe conditions. The line specified here corresponds the PROFInet type, i.e. it is designed for flexible applications with integrated energoe cores.

Part no.

801651, PROFInet type B (SK)

Dimensions and specifications may be changed without prior notice.

R 78


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.