PORTFOLIO HVAC ENGINEER
UZAIR SAYYED MECHANICAL ENGINEER.
SAYYED UZAIR M E C H A N I C A L
E N G I N E E R
To, Allana Group, Aurangabad 431 001.
CONTACT DETAILS +91 80874 67771 uzairsayyed47@gmail.com www.linkedin.com/in/uzairsayyed47 live: uzairsayyed47
Plot no:-33, beside Anisa school, ahbab colony, kat-kat gate road, Aurangabad 431 001.
Subject : - Application for HVAC Engineer job. Dear Hiring Manager, I am wiriting to express my intrest for the mechanical engineer position at Allana group in Aurangabad, Maharashtra.I am confident that my technical knowledge and related industry experience can contribute to your team.Therefore, I want you to consider this application for the mechanical engineer position. I have a bachelor degree in mechanical engineering and a post graduation diploma in HVAC design.I have 1 year 6 months experience in HVAC design and drafting (Autocad & Revit MEP) and 2 years of experience as quality control engineer in Elite Engineers, Waluj, Aurangabad. During my period as HVAC design engineer i have worked on several projects listed :1) Zynova Hospital, ghatkoper,Mumbai. Chilled water project (315 TR) 2) Jindal Villa, nepeansea road, Mumbai. Chilled water project (130 TR) 3) MIT, loni, Pune. VRF/VRV (446 HP) project 4) Small residential flats VRF/VRV projects I look forward to hearing from you in the near Future and hopefully to schedule an interview in which i hope to learn more about your company. It’s goals and plans and how i may be able to contribute to its continued success and growth. Thankyou for your time. Sincerely, Place :
Signature
Date :
Name
Uzair Sayyed
SAYYED UZAIR M E C H A N I C A L
E N G I N E E R
PROFILE •
•
CONTACT DETAILS +91 80874 67771 uzairsayyed47@gmail.com www.linkedin.com/in/uzairsayyed47 live: uzairsayyed47 Plot no:33, Ahbab colony, Kat-kat gate road, Aurangabad-431 001
EDUCATION •
•
Bachelor of Mechanical Engineering D.Y Patil College of Engineering, Pune. (Savitribai Phule Pune University) Higher Secondary Class K.M.E.S Jr. College, Bhiwandi. (Maharashtra State Board)
COURSES & CERTIFICATION • Diploma in HVAC • •
CATIA V5 R21 Six Sigma Yellow & White Belt
PROJECTS • Automatic head-light alignment and automatic hand-brake system • Objective-To provide smooth and safety ride
TECHNICAL SKILLS • • • • • • •
AutoCAD Revit MEP HAP & E20 (EXCEL) Duct Sizer Pipe Sizer CATIA V5 MS OFFICE
A qualified, results-driven Mechanical Engineering Professional with over 1Year hand on experience in HVAC design and drafting. Seeking a challenging position to utilize my potential skills and abilities in the feild of HVAC and Mechanical Engineering that may offer professional growth in me, while being resourceful innovative and flexible to the establishment.
RELEVENT EXPERIENCE Organization Name :Weather Cool Sales Pvt. Ltd. Designation :Design Engineer Period :October 2019-Present Roles & Responsibilities • Heat load calculation in accordance to the building survey following the ISHRAE standard & codes. • Calculating ventilation requirements. • Selection of equipments like (CHILLERS, AHU, FAU, FCU,VRF/VRV etc.) and other accessories and preparing schedule of all the equipments. • Chilled water piping design, pump head calculation with the selection of pumps preparation of riser diagram of chilled water systems. • VRF/VRV layout and pipe sizing on software (Mitsubishi, LG, Midea and etc.). • Duct designing by various methods viz, uniform velocity/equal friction/static regain method. • Modification of ducting as per site requirement and in coordination with actual site condition. • Preparing the measurements of ducting & piping using excel sheet. • Quantity estimation for the project. • Responsible for reviewing shop drawing of HVAC, plumbing and fire fighting. • External Static Pressure(ESP) calculation of duct using SMACNA. • Responsible to clarify and take approval of executed work from consultant and attend weekly progress meeting with consultant, architect, PMC, BMS and other engineering disciplines. • Preparing the As-built drawing for the project HVAC System. • Preparing technical reports and handing over documents.
AWARDS & ACHIEVEMENTS • • •
Won 1st Prize in Chess & Football (School/College) Seminar delivered on CRDi Engine & Solar Power Plant Volunteered sports events ZION & PARAKRAM at Inter College Annual Events
INTERESTS • • •
Football Chess Gaming
LANGUAGES • English • Hindi • Marathi • • • • • • •
PASSPORT DETAILS Passport No. : S8301825 Date Of Issue : 01/10/2018 Date Of Expiry : 30/09/2028 PERSONAL DETAILS Name : Sayyed Uzair Tawqeer Father’s Name : Sayyed Tawqeer Rehman D.O.B : 10th May 1991 Permanent Address : 368, A-201 Naseeba Apt, Samad Nagar, Kaneri, Bhiwand 421 302.
Organization Name :SMEC AUTOMATION Designation :Intern Design Engineer Period :December 2018-March 2019 Roles & Responsibilities • Convergent with various Codes & Standards like ASHRAE, ISHRAE, SMACNA & NFPA. • Proficient to perform document preparation, review drawing, specification & cost estimates for the mechanical, electrical and plumbing. • To review plans and specification of drawing according to plan. • Skilled to analyze space & design parameter selection, duct designing & distribution layout as per project specifications.
OTHER EXPERIENCE Organization Name :Elite Engineers Designation :Quality Control Engineer Period :June 2017-November 2018 Roles & Responsibilities • Visual inspection, product verification as per client specification. • Scrutinizing the task accomplished by shift-wise semi-furnished & furnished production and quality inspection reports & details. • Proper examination and report preparation for incoming raw material. • Examination of furnished product, suitable rework/repair & reexamination. • All the process of PDI (Pre-Despatch Inspection).
DECLARATION I hereby declare that all the information mentioned in my resume is true and correct to my knowledge and I take full responsibility for the accuracy of the particulars mentioned. Place:
Signature
Date :
Name
Project:ZYNOVA HOSPITAL For Referance only 2 out of 12 drawings attached 1) First Floor & 2) Plant Room
4# S. A .DIFF OUTER SIZE 600 x600 375x375mm NECK SIZE 600-CFM 4# R.A.DIFFUSE -600 x600
1# S. A .DIFF OUTER SIZE 525 x525 450x450mm NECK SIZE 700-CFM 1# R.A.DIFFUSE -525 x525
B-B
Trap door 900 x1800mm (Fin in LAM-8)
CONSULT ROOM- 02
CONSULT ROOM- 04
CONSULT ROOM- 03
CONSULT ROOM- 04 CONSULT ROOM-05
CUT-OUT
Trap door 1290 x700mm
FD
220 CFM 250x150 F.A.DUCT 1ST LVL TO UP TO TERRACE LVL
Trap door 1290 x700mm
Trap door 1290 x700mm
Ply ceiling fin in LAM-8
SAMPLE COLLECTION
Cove light
31
Trap door 730 x1325mm
4
1200
LIFT 3.20 X 2.40 M
Ply ceiling fin in LAM-8
WAITING
150
SAMPLE COLLECTION
As per site
TOILET
Cove light
CUT-OUT
LIFT 3.20 X 2.40 M NS
Trap door 2060 x1070mm
Ply ceiling fin in LAM-1
6A Power point to be provided for suspended lt
78
UP
LIFT 3.00 X 2.00 M
LOW HT. STORAGE
5
DN
NS
Trap door 1515 x1070mm
Trap door 1150 x 1290mm LIFT 3.00 X 2.00 M
Cove light HEALTH CHECK-UP
Trap door 1400 x1305mm
Ply ceiling fin in LAM-1
Trap door 1615 x 975mm
TMT /ECHO
1# S. A .DIFF OUTER SIZE 450x450 375x375mm NECK SIZE 635-CFM 1# R.A.DIFFUSE -450x450
PASSAGE
Ply ceiling fin in LAM-1
Ply ceiling fin in LAM-8 FHC
ISOLATION VALVE
Trough 100x100mm
DN
UP
TOILET
As per site
NS
Trough 100x100mm
Trough 100x100mm
OHS
Trap door 1000 x1290mm
3# S. A .DIFF OUTER SIZE 600x600 300x300mm NECK SIZE 400-CFM EACH 6# R.A.DIFFUSE -600x600
FD
M.V.S. 4.30 X 2.90
CUT-OUT
ECG & HOLTER
Ply ceiling fin in LAM-8
EEG & EMG
Trap door 1130 x1290mm
Trough 100x100mm
CH
As per site
CUT-OUT
TOI
Ø75mm SLEEVE
As per site
POSITIVE WASH
Ply ceiling fin in LAM-1
FD
Ply ceiling fin in LAM-8
NEGATIVE WASH
Ply ceiling fin in LAM-8
Trap door 1450x800mm
As per site TOI
As per site
As per site
300
150
Ply ceiling fin in LAM-8
COSMETIC CONSULTATION
As per site M. PUBLIC TOILET
Trap door 1570x1045mm
Trap door 1570x1045mm
ULTRASOUND
CUT-OUT
1200
Trap door 1290x1125mm
F.PUBLIC TOILET
PATIENT CHANGE ROOM
421
A-A
FD
Ø75mm SLEEVE
Trap door 1455x1125mm
DENTAL GYNEC.
4# S. A .DIFF OUTER SIZE 600 x600 375x375mm NECK SIZE 510-CFM 4# R.A.DIFFUSE -600 x600 1st Floor RCP
375
300
2# S. A .DIFF OUTER SIZE 600x600 300x300mm NECK SIZE 300-CFM EACH 2# R.A.DIFFUSE -600x600
300
OPTHAL
1st Floor RCP
Ply ceiling fin in LAM-8
768 900
A A-101
D-D
E-E
2 WAY MOTORIZED MODULATING VALVE BY PASS LINE 100mmØ
P28A 400X2550
CUT-OUT
OPEN TERRACE MS PLATFORM AT 2.0mtr LEVEL. FOR FAN
CL1 3500X300
LIFT 3.20 X 2.40 M
CL4 300X5700 CL2
M.S.STAIRCASE AS PER VENDOR
01
3500X300
I.1.14 LIFT LOBBY 2900 X 5275 19 18 17 16 15 14 13 12 11
10 09 08 07 06 05 04 03 02 01 19 NO.RISERS RISER=173.6 MM TRADE=250 MM
UP CUT-OUT
LIFT 3.20 X 2.40 M CL3 4600X300
L1A
WAITING 5925 X 4375
I.1.15
C5FLOOR MANAGER CABIN 800X800
LIFT LOBBY 3400 X 6025
UP DRINKING C7A WATER
24 23
1150X450
01 03
21 20
04
19
LIFT 3.00 X 2.00 M
L3A 1600X400
02
22
NURSE STATION
05 18
06 07
17
08 09 10
14
300X3300
C7
D-D
PREMIERE ROOM-01 5100 X 3490
3900X300
ST 300 X 450
TD.804 C7B
TOILET
L3
TD.805
3000X300
1000X450
24 23
UP
DN 01
02
22 TOILET 3000 X 1510
03
21 20
C8 300X2800
19
04 05
18
06 07
17
CUT-OUT
01
MM WIDE CORRIDOR
13 12 11 TOILET 2100 X 1650
01 C8A FULL HT. STORAGE
15
3900
16
C6
LIFT 3.00 X 2.00 M L2 3300X300
1600X400
01 + 130.10 M. LVL.
DN
L1 3000X300
16 15
08 09
14
10
Project:JINDAL VILLA For Referance only 2 out of 7 drawings attached 1) 3rd Floor & 2) 4th Floor
THIRD FLOOR
DATA
DATA
HDMI
TV/AV
2 DATA
CP CP
S16
S15
S17
F9
F10
S18
FO
FT
F1
F2
E2
F E F6
F5
S14
STAFF LIFT
E1
UP KP
F
F4
STAIR 2
E4
S7
S12
F
F4
5777
75 S8 TC
S4
KP
M
F5
DP
S2 M
CP CP
S7
S8
S9
S6
M
LOBBY
255
S5
T S2
S12
S10
S1
5
FD
S12 S1
CP CP
(WP)2
DATA
S18
S17
S16
M
S2
18
M
DATA
S1 T
S
S21
S19
Ø2 85 0
M
2
20
S20
16
S12
AREA 2 POOJA ROOM
22
DRESSING
AREA
14
T
S4
FB
DN
M
S5
HDMI
S11 S10 S9 S8
AREA 8 PARTH'S BEDROOM
(WP)2
CP
S15
S14
KP
2
CP CP
M
5
S18
S142 S15
TC KP
S11
S15
5
DATA
M
S1
DATA
2
KP
F
S16
S11
S1
S
E8E7
S14
TV/AV
AREA 1
S10
F6
S4
F7
TC KP
S17
S8 S9
S
AREA 4
TC KP
KP TC
BEDROOM 5
DF
F6
S1
S16
S
F4
F4 F6 ENSUITE 5
CP CP
S7
S6
S5 S4
E
8947
FD
DATA
KP
S
(WP)2
T
TV/AV HDMI
M
S9
S6 S5
F7
F8
DRESSING 5 DRESSING S1 S2 5
E6
FT
M
S10
DN
F2
F2
T
S11
MAIN LIFT
F2 F1
FT
F8
E2
F5 E2 E F4 F E5 E4
KP
AREA 7
NURSERY ENSUITE 125
F11
KP
LOUNGE/ NURSERY
DATA
S1
E1 F1
12
10
5
S22
M
KP
S19 2
KP
TC KP
5000 S2
M
S24
S25
S26
FD
DATA
CP
GALLERY +114.700 FFL +114.625 SSL
S6
S7
24
CP
S28
CP
S20 FT
KP
T KP TC
FB
E12
FT
AREA 6 STUDY S8
F14 E F F2
FO
F
E1
E5
HDMI
DATA
4
S7
F8
CP CP
F11
F10
F7 F5
DP
S21
S14
E9
S
E4
F9
F6
F1 KP
E2
E6
BATHROOM 5
FO
E7
FT
S6
FB
S2 E8
S20
S15
S1 KP
S19
S4
AREA 5
S5 HDMI
F4
F6
F5
F7
FT
DATA
F9
E5
DATA
S
S4
S5
2
E14
E4
E6 E7
S2
S9
HDMI
F10
F1
F11
E9
POWDER POWDER S1 ROOM ROOM
TV/AV
E11
E10
E1
S10
S16
S18
T
F8
DATA
F
E8
F12
S11
DATA
TV/AV
CP CP
PARTH'S ENSUITE
S2
S24
DATA
S25
~
S27 S26
LIBRARY LOUNGE
5
FD
AREA 9
S22
S12
DATA
S21
S17
F4
F
S6
F2
S7
FO
F1
TV ROOM
S1
S11
S12
E
F
E1 E2
S8
S9
S10
CP CP
1200x300 WALL CUTOUT FOR DUCT B.O.CUTOUT-3050
S1
FOURTH FLOOR
A2x6
AREA-8 T
S2 F3
F4
S11
401
C1
S7
1000 CFM 450x250
R.A.DUCT 550x250
SERSERA1-ICE ICE LIFT F2 LOBBY IR 413 LIFT LOBBY
IR
A9
EL DT SH RC IRC-C IEL-C IDT-C ISH-C
IEL-C IDT-C
150
EL DT
50
77
A9
DN
1400x300 WALL CUTOUT FOR DUCT
5040
90
A5
30 CFM B2 150x100 (2.4m) (TYP) E5 35 CFM 150x100 (TYP)
F1 E4
300
A5 L
S5 S4ROOM DINING
S15
A10
B4 x4
B4 x2
S14 S13 S12
IR
B4S11
B4
B4
409
A2
S10
B4
AREA-3
A2
S1
3150@BOD
S3
S4
B4
468 CFM 250x200
560
B4 x3
A1
416
S1
S2
S5
CORRIDOR
600x200 R.A.DUCT
412
S8
560
XA2
S1
312 CFM 200x200
T
DRESSING DRESSING 3 3
S2
156 CFM 100x200
S9
BEDROOM 3
50
IR
A2x2 AREA-1
S11
805
2365
S6
S10
960
F7
XA2
B3 (8.7m)
F2 F4
T
S8
B3 (5.9m)S9
F2
300
A2x2
S10
S12
WIFI
A10
A2
E2 410 E1
A1
DP
130
B4 x2
715 CFM 300x250
ENSUITE 3
E3
F3
F5
F6
429 CFM A2x2 200x250
WC
B3(4.6m)
S15 S14 156B3CFM (11.1m) S13 100x200
A6
F1 100
285 CFM 200x200
B-B
95 CFM A1150x150
ELECTRICAL RISER
IR
414
325
S3
A9
UP
S1
A2x8
DINING ROOM
A9
A2
1790
F
40mmØ TO NEAREST SHAFT FLOOR DRAIN
L
895
SER ERY
STAFF LIFT
402
SER ERY
2365
A2
S4
S3 3100@BOD 1000 CFM 450x200
S7
532 CFM S5 300x200
S6
C-C
S6 S10
B4 x2
A2x2
S9
GALLERY S7 118.550 FFL 118.475 SSL
S16
F
XA2
S15
S8 AREA-9 A1x4
A1x4
L
S17
B3 (10.3m) S16
B4
895
A2X2 XA3 (4m)
WIFI
B3 (2.9m)
B4 x6 A2
A1X3
AREA-4 A1x2
S9
LOUNGE
F
S8
S17
S7
A2
B4
A1X3
GALLERY LOUNGE
S63100@BOD IR
AREA-2
411
S18
S7
UP
S14
B4
AREA-5
B4
XA1x3
B4
A2
S5
B4 x6
XA2
S18
A2x2
S17
S15
S4
S14 T
30 CFM 150x100
A1
F8
B.O.D@2850 A1 B.O.D@2850 E9
E9
A2x2
E10
1635
1085
464 CFM B4 x3 250x200
E2 E1 F3
S12
E3
L
F9 F8 30 CFM 100x100A1 60 CFM DP 150x150
S2
30 CFM 100x100
S1
S6
F5 F4
B1 (3.5m) 565
E6
E5
E4
F7
S11
S10 268 CFM 150x200
S9
S8
1000 CFM 450x200 S4E7 S5 3100@BOD
XA2
B3 (10m)
S7
AREA-6
S3 F6 408F4
F3
ENSUITE 4 A1
155
S2
ENSUITE 4 F5
B4
T
F10
S3 A3
A3
A7 (5.2m)
E6
2365 570
S7 F
CP CP
32mmØ TO NEAREST SHAFT FLOOR DRAIN
A3
A3
S1
F11
1300x300 WALL CUTOUT FOR DUCT
F2
376 CFM 250x200
BEDROOM 4
S6
E4 F1 F12 F13 E5 45
CFM B2(1.8m) 200x100 A2x2
E3
S10 S11
A2
F-F
50mmØ TO NEAREST SHAFT FLOOR DRAIN
S15
312 CFM 200x200
624 CFM 300x200
E1 E2
550x300 WALL CUTOUT FOR DUCT B.O.CUTOUT-3050
A2x2
A6
2850@BOD
2#100x100 F.A.&EX.GRILL
S5
D-D
2185 100
T
B3 (2.6m)
S8
A1
B3 (12.4m)
1000 CFM S4 450x200
A3
F1
F2
E7
A1
3050@BOD
A1 1185
670
A3
F7
F6
F
536 CFM 300x200
C1
60 CFM 150x150 A1
E8
B4 x5
L
960
895
765
535
S2 S1
WIFI
B4
A1
A1
E-E
A2x2
S3
S5
417
1465
895
XA2
CONCEALED SUBWOOFER S4
POWDER A1 ROOM
CP CP
CONCEALEDS11 SUBWOOFER
T
S13
S12
AREA-7
1700x300 WALL CUTOUT FOR DUCT B.O.CUTOUT-3050 A2 S9
DRESSING 4
S2 S1
915
100
S13
S3
F
895
100
100
A-A
B3 (13.4m)
750x500A2 WALL CUTOUT FOR DUCT
B4
B4 x3
L
S19
A2x2WIFI
50
S6
268 CFM 150x200 S16
XA2
S12
S13 A2
B3(4.5m) S14
Project:MIT PUNE For Referance only 2 out of 9 drawings attached 1) 6th Floor (Indoor unit) & 2) Terrace (Outdoor unit)
A-607
SIX FLOOR
1
2
3
4
5
6
7
8
9 10
11
12
13 14
15 16
17 18
FFL +26.00M
FFL +25.700M
FFL +25.400M
SA DIFFUSER NECK 614 SIZE-15" X 15" EACH DIFF- 914 CFM
FFL +25.100M
FFL +24.800M
FFL +24.500M
600x700 3200 CFM EACH
FFL +23.900M
TOILET
6'10"X3'5"
DN
FFL +23.650M
SHAFT - 4 TOILET
CMY-Y302 CMY-Y102 S-G2 SS-G2
6'10"X3'5"
Ø32 MM (TYP) AC DRAIN PIPE
FFL +23.400M
SYS-13 26 HP
SHAFT - 2
A-611 to
615
Ø32 MM (TYP) AC DRAIN PIPE
FFL +23.200M
SYS-4 24 HP
FFL +24.200M
611/613
19 20
FD
10" X 4"
10" X 4"
12" X 10"
138 CFM
MANUAL
LAB - ASST
PROF.
550x400 SAD 2743 CFM
800x500 SAD 4571 CFM
1100x500 SAD 6400 CFM
FD
LAB - ASST
PROF.
600x250 SAD 914 CFM
MANUAL
SYS16 HP
1.02TR / 1.25HP 4 WAY CASSETTE W840xD840xH258 494 CFM PANEL W950xD950xH35
AHU
FD
CABIN 7
FRD
6400CFM AHU 16 TR
MANUAL
UP
WAITING AREA 10'2" X 14'0"
CABIN 6
CABIN 5
MANUAL
2.02TR / 2.5HP 4 WAY CASSETTE W840xD840xH258 636 CFM PANEL W950xD950xH35
CONFERENCE ROOM 26'4" X (10'8"+14'4")/2
24" X 10"
MANUAL
10 # 1.59TR / 2.0HP CASSETTE UNIT
4.5TR/ 5.62 HP
610
MANUAL
4.0TR / 5.0HP 4 WAY CASSETTE W840xD840xH298 1059 CFM PANEL W950xD950xH35
1100x500 SAD 6400 CFM
FD
CABIN 4
HOD'S ROOM 16'0" X 10'0"
8" X 6"
6400CFM AHU 16 TR
F
CABIN 1
CABIN 2
12" X 6"
MANUAL
PANTRY 4'3" X 7'3"
MANUAL
CABIN 3
Entry/Exit
2 # 4.0TR / 5.0HP 4 WAY CASSETTE
FD
N-617 VIP ROOM 5.2M x 3.0M FFL + 21.950 M
10" X 4" 138 CFM
2 # 4.0TR / 5.0HP 4 WAY CASSETTE
LOBBY/SNACK AREA
550x400 SAD 2743 CFM
5 4 2
B
D1
5
6
7
8
9 10
11
12
13 14
15 16
17 18
19 20
FFL +26.00M
4
FFL +25.700M
3
FFL +25.400M
2
FFL +24.500M
1
FFL +24.200M
Entry/Exit
FFL +23.900M
FFL + 21.950 M FFL +23.650M
10" X 4"
ELEC. ROOM 2.5M x 3.0M
G.R 2 2.5M x 3.0M
FFL +23.400M
D1
FFL +23.200M
12" X 6"
8" X 6"
1
FFL +25.100M
24" X 10"
800x500 SAD 4571 CFM
D1
3
12" X 10"
SHAFT - 3 SYS-7 20 HP
G.R 1 5.2M x 3.0M FFL + 21.950 M
600x250 SAD 914 CFM
DN
D1
FFL +24.800M
A-617 Tutorial Room 12
Ø32 MM (TYP) AC DRAIN PIPE
N-616
A-604 Class Room 37
550x400 SAD 2743 CFM
B
4.5TR/ 5.62 HP
UP
800x500 SAD 4571 CFM
FD
A-605 Class Room 38
1100x500 SAD 6400 CFM
600x250 SAD 914 CFM
6400CFM AHU 16 TR
SIXTH FLOOR
CONTROL ROOM
1100x500 SAD 6400 CFM
WHITE BOARD
SCREEN
FFL + 23.900 M
WHITE BOARD
SCREEN
A-615
A-614 A
A-618 Class Room 41 AC
A-603 Class Room 36
A-619 Microprocessor Lab AC
Ø32 MM (TYP) AC DRAIN PIPE
4.0TR / 5.0HP 4 WAY CASSETTE W840xD840xH298 1059 CFM PANEL W950xD950xH35
12" X 10"
138 CFM
4.5TR/ 5.62 HP
CONFERENCE ROOM 26'4" X (10'8"+14'4")/2
HOD'S ROOM 16'0" X 10'0"
WAITING AREA 10'2" X 14'0"
10" X 4"
1.28 TR / 1.7HP 4 WAY CASSETTE W840xD840xH258 565 CFM PANEL W950xD950xH35
TOILET
6'10"X3'5"
8" X 6"
PANTRY 4'3" X 7'3"
24" X 10"
F TOILET
6'10"X3'5"
10" X 4"
A-602 603
604
12" X 6"
SHAFT - 1 2.02TR / 2.5HP 4 WAY CASSETTE W840xD840xH258 636 CFM 1/4-1/2 PANEL W950xD950xH35
SYS-3 16 HP
Ø32 MM (TYP) AC DRAIN PIPE 2.02TR / 2.5HP 4 WAY CASSETTE W840xD840xH258 636 CFM PANEL W950xD950xH35
1.0TR / 1.25 HP HI-WALL UNIT
Tutorial Room 13 1.0TR / 1.25 HP HI-WALL UNIT
CLIENT:MIT-ADT UNIVERSITY
602
CONSULTANT:-
DN VIJAY KAPOTE 1.0TR / 1.25 HP HI-WALL UNIT
UP
HVAC VENDOR:EA HER COOL SALES L D
1.0TR / 1.25 HP HI-WALL UNIT
HVAC LAGEND VRF OUTDOOR UNIT
V
201/A SHUBAM CENTRE NO.1, CARDINAL GRACIOUS ROAD,
4 WAY CASSETTE
CHAKALA, ANDHERI (E), MUMBAI - 400 099.
HI-WALL UNIT REF COPPER PIPE
TEL:- 61957913, 61957900 / FAX - 61957900 EMAIL ID :- / project@weathercoolsales.com
REFNET JOINT DRAIN PIPE DRAIN PUMP
ACOUSTIC INSULATION
DRAWING TITLE: HVAC LAYOUT SIXTH FLOOR FOR MIT-ADT SITE AT LONI PUNE
FD
AIRTIGHT PARTITION
DRAWN BY :
SOUND ATTENUATOR
CHECKED BY : SUSHIL SIR
SCALE :
APPROVED BY : SUSHIL SIR
REV DATE : 11.11.2019
SUBHASH
REV NO :
01 N.T.S
TERRACE FLOOR SHAFT - 3 8.5 TR ODU
SHAFT - 4 8.5 TR ODU
7/8",3/8" 10 HP
11/8",5/8"
18 HP
11/8",5/8"
20 HP
12 HP
20 HP
7/8",1/2"
11/8",5/8"
14 HP
11/8",5/8"
18 HP
11/8",1/2"
10 HP
7/8",3/8"
20 HP
20 HP
13/8",3/4" 18 HP
11/8",5/8"
11/8",5/8"
15/8",3/4" 15/8",3/4" 18 HP
11/8",5/8"
SYS-11 (36 HP) OUTDOOR UNIT (18HP+18HP)
11/8",5/8"
18 HP
11/8",5/8"
11/8",5/8"
8.5 TR ODU
SYS-9 (36 HP) OUTDOOR UNIT (18HP+18HP)
15/8",3/4"
16 HP
20 HP
15/8",3/8" 18 HP
UP
SHAFT - 5
16 HP
18 HP 18 HP
11/8",5/8"
11/8",5/8"
8.5 TR ODU
18 HP
8.5 TR ODU
7/8",1/2"
8.5 TR ODU
14 HP
8.5 TR ODU W900XD580xH960
SYS-4 (24 HP) OUTDOOR UNIT (14HP+10HP)
DN 18 HP
8.5 TR ODU W900XD580xH960
SYS-10 (36 HP) OUTDOOR UNIT (18HP+18HP)
11/8",5/8"
15/8",3/8"
11/8",5/8" 14 HP
20 HP
7/8",3/8" 16 HP
11/8",5/8" 7/8",1/2" 13/8",3/4"
SYS-5 (20 HP) OUTDOOR UNIT
SYS-12 (36 HP) OUTDOOR UNIT (18HP+18HP)
11/8",5/8" 20 HP
20 HP
11/8",5/8"
SYS-8 (40 HP) OUTDOOR UNIT (20HP+20HP)
SYS-13 (26 HP) OUTDOOR UNIT (16HP+10HP)
15/8",3/4"
7/8",1/2"
SYS-7 (30 HP) OUTDOOR UNIT (14HP+16HP)
SYS-17 (60 HP) OUTDOOR UNIT (20HP+20HP+20HP)
11/8",5/8"
20 HP
20 HP
SYS-6 (40 HP) OUTDOOR UNIT (20HP+20HP)
SYS-16 (18 HP) OUTDOOR UNIT
11/8",5/8" 11/8",5/8"
SYS-14 (44 HP) OUTDOOR UNIT (12HP+14HP+18HP)
15/8",3/4" 15/8",3/4"
SYS-15 (40 HP) OUTDOOR UNIT (20HP+20HP)
DN
UP
N W
E S
16 HP
SYS-3 (16 HP) OUTDOOR UNIT
11/8",1/2" 20 HP
SYS-2 (20 HP) OUTDOOR UNIT
11/8",5/8"
OUTDOOR UNIT SIZES
18 HP
11/8",5/8"
SYS-1 (40 HP) OUTDOOR UNIT (20HP+20HP)
20 HP
SYS-1 (38 HP) OUTDOOR UNIT (20HP+20HP)
11/8",5/8"
W920xD740xH1650 10 HP
CLIENT:MIT-ADT UNIVERSITY
W920xD740xH1650 12 HP
15/8",3/8"
CONSULTANT:-
VIJAY KAPOTE
W1220xD740xH1650 14 HP
HVAC VENDOR:WEATHER COOL SALES PVT. LTD.
DN
W1220xD740xH1650 16 HP
201/A SHUBAM CENTRE NO.1, CARDINAL GRACIOUS ROAD, CHAKALA, ANDHERI (E), MUMBAI - 400 099. TEL:- 61957913, 61957900 / FAX - 61957900
UP
W1220xD740xH1650 18 HP W1750xD740xH1650 20 HP
HVAC LA E D
EMAIL ID :- / project@weathercoolsales.com
VRF OUTDOOR UNIT 4 WAY CASSETTE HI-WALL UNIT REF COPPER PIPE REFNET JOINT DRAIN PIPE DRAIN PUMP
DRAWING TITLE: HVAC LAYOUT TERRACE FLOOR FOR MIT-ADT SITE AT LONI PUNE DRAWN BY :
SUBHASH
REV NO :
01
CHECKED BY : SUSHIL SIR
SCALE :
APPROVED BY : SUSHIL SIR
REV DATE : 11.11.2019
N.T.S
Project:Qashr-e-aisha (Flat Residential) 16th Floor drawing attached
16TH FLOOR HVAC LAYOUT WINDOW SILL 18 " WINDOW HEIGHT 102" WINDOW ABOVE 20" (BEAM)
WINDOW SILL 38 12"+12"ht Floor beam WINDOW HEIGHT 80 14" WINDOW ABOVE 8" (BEAM)
SCALE-1/4"-1'
FALSE CEILING HT - 9'-3" FFL
ROOM HT -
DL3
M. W. SHOWER (5'-3" X 6'-0") M. W. WC (8'-0" X 4'-0")
ROOM HT - 138"
FALSE CEILING HT - 11'-0" FFL
C
G. WC (5'-0" X 5'-3")
100 CFM CASSETTE TYPE EX AIR FAN
BB - 128 12"
BH - 12 "
G. SHOWER (5'-0" X 5'-3")
FALSE CEILING HT - 9'-6" FFL
SLAB HT - 10'-3" FFL
SLAB HT - 11'-2" FFL
M. W. BASIN AREA (9'-0" X 9'-6") MA. BED. PASSAGE (4'-0" X 8'-0")
22.2,12.7
SLAB HT - 11'-5" FFL
BH - 12"
1.5 TR 2.0 HP
FOOT LIGHT
FOOT LIGHT
RBM-BY55E
FALSE CEILING HT - 9'-6" FFL SLAB HT - 11'-2" FFL
SLAB HT - 10'-3" FFL
BB - 116"
ENTRY 28.6,12.7
12.7,6.4
LIFT - 1
FALSE CEILING HT - 9'-6" FFL SLAB HT - 10'-6" FFL
1'-3"
CHI. WASHROOM (5'-8" X 6'-9")
FALSE CEILING HT - 11'-0" FFL
ROOM HT - 139 14"
FALSE CEILING HT - 9'-6" FFL
FALSE CEILING HT - 11'-0" FFL
2 NOS S.A & R.A DIFFUSER DW 353 CFM EACH 24"x24 (N/S-12"x12)
PENDENT LIGHT
SLAB HT - 11'-3" FFL
ELECTRICAL DUCT SYSTEM-2
DL3
SLAB HT - 11'-2" FFL
4 NOS S.A.COLLAR 353 CFM EACH 16"x6"
SLAB HT - 11'-6" FFL SLAB HT - 11'-3" FFL
CHI. SHOWER (3'-5" XDL36'-9")
FALSE CEILING HT - 10'-9" FFL
SLAB HT - 11'-2" FFL
ROOM HT - 142 14"
LIFT LOBBY (6'-6" X 21'-10")
LIFT - 2 SYSTEM-1
DINING ROOM (18'-3" X 16'-3")
FALSE CEILING HT - 9'-6" FFL
1413 CFM 22"x10"
T 706 CFM 12"x10"
2 # 12 HP OUTDOOR UNIT TOP DISCHARGED ALL REF PIPE GOING UP TO TERRACE FLOOR
1TR / 1.25HP 1 WAY CASSETTE W34"xD16"xH10" 318 CFM PANEL W42"xD19"xH1"
T 1 KITCHEN (10'-0" X 16'-0")
WINDOW SILL 18 12" WINDOW HEIGHT 101 3 8" WINDOW ABOVE 17 3 4" (BEAM)
1TR / 1.25HP BB - 127" 1 WAY CHI.CASSETTE WALK IN W34"xD16"xH10" (9'-2" X 6'-11") 318 CFM PANEL W42"xD19"xH1"
BUILT IN REFRIGERATOR
BH - 21"
BH - 12"
CHILDREN BEDROOM (13'-8" X 19'-3") 2 NOS 1.5TR / 2HP 1 WAY CASSETTE W40"xD28"xH8" 459 CFM PANEL W49"xD32"xH1"
KITCHEN 2 (8'-0" X 19'-6")
LIVING ROOM (16'-6" X 16'-8")
BH - 12 "
9.5,6.4
5.71 HP
BH - 5 "
28.6,12.7 SLAB HT - 11'-3" FFL FALSE CEILING HT - 9'-6" FFL
STORE & UTILITY ROOM (9'-9" X 7'-0") 4.57 TR
BB - 125 "
FALSE CEILING HT - 9'-6" FFL SLAB HT - 11'-6" FFL
15.9,9.5
BUILT IN OVEN & MICROWAVE
(9'-8" X 3'-6")
2 # 4.57 TR /5.71 HP HIGH STATIC DUCT TYPE W56"xD30"xH12" 1413CFM TRAPDOOR W67"xL48"
WASHING MACHINE
STAIRCASE
- 19" 12.7,6.4CHILDREN B.BHPASSAGE
QIBLA
WINDOW SILL 17" WINDOW HEIGHT 102 12" WINDOW ABOVE 19 12" (BEAM)
A
T
BH - 4"
BH - 19"
1 " LIGHT BBFOOT - 123 4
T WES
WINDOW SILL 18 3 4" WINDOW HEIGHT 101 3 8" WINDOW ABOVE 17 12" (BEAM)
FALSE CEILING HT - 9'-6" FFL
RBM-BY105E
4"
RBM-BY105E
3
A
BH - 9
SLAB HT - 10'-4" FFL
15.9,9.5
ENTRANCE LOBBY (29'-11" X 5'-9") RBM-BY105E
22.2,12.7
15.9,9.5
SLAB HT - 11'-2" FFL
FOOT LIGHT
BB - 127 14"
STUDY ROOM (11'-9" X 11'-9")
FALSE CEILING HT - 9'-6" FFL
BB - 127 14"
15.9,9.5 FALSE CEILING HT - 9'-6" FFL
BH - 12 3 4"
RBM-BY55E
15.9,9.5
22.2,12.7
BH - 12 12"
BB - 128 12"
2 MTR RBM-BY55E
15.9,9.5 c2 profile
FALSE CEILING HT - 10'-9" FFL
RBM-BY105E
FOOT LIGHT
6" SUPPLY AIR & RETURN AIRGRILL
1413 CFM 22"x10"
4.57 TR 5.71 HP
FOOT LIGHT
BB - 128 12"
BH - 14 3 4"
SLAB HT - 11'-6" FFL
15.9,9.5
PENDENT LIGHT
T LOCK LOBBY (4'-3" X 5'-6")
c2 profile
BEDROOM LOBBY (29'-11" X 5'-9")
S.A.COLLAR 282 CFM EACH 16"x6"
MDB 12.7,6.4
RBM-BY105E
FAMILY ROOM 5 NOS (18'-3" X 16'-6")
DL3
MA. WALK IN WARDROBE (11'-9" X 20'-3")
FOOT LIGHT
FALSE CEILING HT - 11'-0" FFL
C
GUEST BEDROOM (10'-6" X 20'-3")
2 NOS 6" DISC VOLVE G. WALK IN 75 CFM EACH (8'-3" X 10'-6")
DL3
M. W. BATHTUB 9'-0" X 5'-0")
SLAB HT - 11'-2" FFL
FOOT LIGHT
WINDOW SILL 18 12" WINDOW HEIGHT 10112" WINDOW ABOVE 19 3 4" (BEAM)
SLAB HT - 11'-5" FFL
FALSE CEILING HT - 9'-6" FFL
WINDOW SILL 18 " WINDOW HEIGHT 101 18" WINDOW ABOVE 17 12" (BEAM)
FALSE CEILING HT - 10'-9" FFL
SLAB HT - 10'-4" FFL
12.7,6.4
2TR / 2.5HP 1 WAY CASSETTE W40"xD28"xH8" 671 CFM PANEL W49"xD32"xH1"
PENDENT LIGHT
PENDENT LIGHT
FALSE CEILING HT - 9'-6" FFL
POWDER WASHROOM (8'-9" X 5'-6")
MMD-AP0186BHP1-E 1.5TR / 2HP CONCEALED DUCT TYPE W28"xD30"xH11" 470 CFM TRAPDOOR W46"xD48"
FALSE CEILING HT - 9'-3" FFL
150 CFM EX AIR FAN
141 12"
12.7,6.4
WINDOW SILL 19" WINDOW HEIGHT 101" WINDOW ABOVE 22 12" (BEAM)
FALSE CEILING HT - 9'-3" FFL
FALSE CEILING HT - 9'-6" FFL
SLAB HT - 11'-4" FFL
MASTER BEDROOM (19'-0" X 17'-3")
WINDOW SILL 18 " WINDOW HEIGHT 101 14" WINDOW ABOVE 17 12" (BEAM)
B
1.5 TR 2.0 HP
FALSE CEILING HT - 11'-0" FFL
WINDOW SILL 53 14" WINDOW HEIGHT 70 12" WINDOW ABOVE 8" (BEAM)
848 CFM 14"x10"
B
2TR / 2.5HP 1 WAY CASSETTE WINDOW SILL 17 " W40"xD28"xH8" WINDOW HEIGHT 102 12" WINDOW ABOVE 17 3 4" (BEAM) 671 CFM PANEL W49"xD32"xH1"
FALSE CEILING HT - 9'-3" FFL
FALSE CEILING HT - 9'-3" FFL
FALSE CEILING HT - 9'-6" FFL ROOM HT - 140"
1 NOS 1.5TR / 2HP 1 WAY CASSETTE W40"xD28"xH8" 459 CFM PANEL W49"xD32"xH1"
150 CFM Ø6" PVC PIPE
2 NOS 1.5TR / 2HP 1 WAY CASSETTE WINDOW SILL 18 12" W40"xD28"xH8" WINDOW HEIGHT 101 3 4" 459 CFM WINDOW ABOVE 19 12" (BEAM) PANEL W49"xD32"xH1"
6" SUPPLY AIR & RETURN AIRGRILL
PASSAGE FALSE CEILING HT - 9'-6" FFL
100 CFM CASSETTE TYPE EX AIR FAN
1.5TR
WINDOW SILL 17" WINDOW HEIGHT 102" WINDOW ABOVE 19"
FALSE CEILING HT - 9'-3" FFL
1413 CFM WINDOW SILL 16 12" 10"x22"
1.5TR
WINDOW SILL ?" WINDOW HEIGHT ?" WINDOW ABOVE ?"
WINDOW SILL 39" WINDOW HEIGHT 79 12" WINDOW ABOVE 23"
WINDOW HEIGHT 100 14" WINDOW ABOVE 23" (BEAM)
7
T.C.H-9'-108"
1
F/C H-8'-58"
3
F.C.H-9'-68"
5
B.O.DUCT-8'-88"
1
F.C.H-8'-58"
5
B.O.UNIT-8'-88"
7
B.O.BEAM-9'-28"
7
T.C.H-9'-108"
B.O.UNIT-10'
F/C H-9'-6"
B.O.DUCT-9'-11"
B.O.SLAB11'-4"
F/C H-9'-6"
F/C H-10'-10"
F/C H-9'-6"
B.O.DUCT-10'-5"
B.O.FLC-9'-8"
B.O.UNIT-10'-2"
4.57 TR
LEGEND WINDOW SILL 41" WINDOW HEIGHT 79" WINDOW ABOVE 17 12" (BEAM)
SECTION -B....B
SECTION -A....A
HVAC LAYOUT 16TH FLOOR
VRF ODU DUCTABLE UNIT
PROJECT :-
1 WAY CASSETTE
ARCHITECT
DESIGN
DATE :-
16.08.2019
REFNET REF- PIPE DRAIN PIPE SUPPLY DUCT
SECTION -C....C
TITLE :-
WINDOW SILL 18 12" WINDOW HEIGHT 101 14" WINDOW ABOVE 17 12" (BEAM)
S.A & R.A GRILL V.C.D
QASHR-E-AISHA RESIDENCE MUMBAI CENTRAL
CLIENT NAME :- QASHR-E-AISHA
JOB NO:SCALE :-
N.T.S
DRAWN BY :-
SUBHASH
CHECKED BY :-
SUSHIL SIR
APPROVED BY :- SUSHIL SIR
MATRIX
WEATHER COOL SALES PVT. LTD. 201/A SHUBAM CENTRE NO.1, CARDINAL GRACIOUS ROAD, CHAKALA, ANDHERI (E), MUMBAI - 400 099. TEL:- 61957913, 61957900 / FAX - 61957979 EMAIL ID:-project@weathercoolsales.com
AUTODESK
4SMEC
REVIT
Certificate of Completion SAYYED UZAIR TAWOEER
This is to tertifp that
pas successfullp completed the DIPLOMA IN HVAC
Training Program, held at our institute with an aggregate grade.
matin
A
SMEC Kochi 5MEC Jrom_ 05 December,2018 Date of Issue
05 January, 2019
Certiticate no. SLTH/18/18320
1
05 January,2019 N
Head ot Tráining
www.smeclabs.com
CERTIFICATE OF COMPLETION This is to certify that
Uzair Sayyed Has pursued studies and completed all the requirements for
Revit Level 1 (Beginner) www.infratechcivil.com
Issued on 2020-07-04
Certificate ID: bia2vkz43z
AUTODESK
ASMEC
REVIT
Certifirate of Comnpletion SAYYED UZAIR TAWQEER
This is to certifp that
yas successtully tompleted the REVIT MEP Training Program
SM
ECAu
held at our institute
PII
from 26 December, 2018
2019
Wo
05
January,
Bate of 3ssue
05
January, 2019
Certificate no. SLTH/18/18320
Headraíning
www.smeclabs.comn
4SMEC
AUTODESK AUTOCAD
Certificate of Completion SAYYED UZAIR TAWQEER
This is to tertilp that
pas successtullp tompleted the Computer Aided Design (CAD) Training Program held at our institute, with intensive pratical orientation in the following:
2D DRAFTING-DRAWING TOOLS-MODIFICATION TOOLSISOMETRIC DRAWINGS-MACHINE DRAWINGS-PLOTTING.
From
05 December,2018
To 15 December.2019
Certificate no. sLTH/18/18320
Date of 3ssue 15 December,2019
AUTODESK.
matio 5MEcE -1
Head ofTtalming www.smeclabs.com
CORE CADD SOLUTIONS An ISO 9001-2008 Certified Institute
Certificate This is to certify that Mr. Sayyed Vzair Tawqr has
successfuly completed Catia V5 R21 course held 6y Core Cadd Solutions in the month of Apnil-May 2015 and was
placed in A+ grade. ECAD D SOL Pune 411 035
CORECADD CAD SOLUTIO
LUTIO
ISo 1-2008
Partner
SO9001-2003 A-212, 2nd Floor, Shri Jai Ganesh Vision, Next to Fame Inox, Akurdi, Pune-411 035. Mob. No. : 8855036214, 88S5036242 E-mail: vasudha.corecadd@gmail.com
COURSE CERTIFICATE
08/25/2020
TE S
E
C
U
R
A
E DU CO
NE
an online non-credit course authorized by National Taiwan University and offered through Coursera
N FO R E V E
YO
BIM Application for Engineers
T
IO
R
has successfully completed
CA
UZAIR TAWQEER SAYYED
F CERTI
I
謝尚賢 教授 土木工程學系
Verify at coursera.org/verify/YVE2UBPMLHD2 Coursera has confirmed the identity of this individual and their participation in the course.
Uzair Sayyed
Granted Date : September 2, 2020 732843
Uzair sayyed Compressor Date : 30-05-2020
Uzair sayyed Fan and Blower Date : 31-05-2020
Uzair sayyed Advance Microsoft Excel Date : 30-05-2020