MEASUREMENT SHEET
ForallItemsinallSections:Rateshallincludetransportation,loading/unloading,providing/supplying/laying/fixing/installing/ fabricating/testing/commissioningetconsite RateshallalsoincludealltaxessuchasVAT,excise,salestax,octroi,etc
SECTION-I: SitePreparation&Cleaning
Cleaningandclearingthesiteofallrocks,boulders,brick-bats,stone,bushes, shrubs,etccomplete,asdirectedbythearchitectforstartofconstructionactivity
SECTION-II: CIVILWORK
Note:
1)TheitemsgivenbelowshallbeasperSectionA""Earthwork,MetalPacking& SubsurfaceDrainage"ofthespecifications
2)Rateforexcavationshallincludedewateringduringtheexcavationincluding shoring,struttingetcandkeepingitdryduringexcavationandconstruction
3)AllearthworkshallbecarriedoutasperConservationArchitect'sinstructions andsafetynormsasperrelevantIScode Therateshallincludeallscaffolding andmeasuresforcordoningoffareasduringdismantling,providingsignboards etc
4)Alldebrisandscrapmaterialsfromearthworkshallbecontractorspropertyother thanthatwhichisreusedforback-fillingetc andthisdebrisandscrapmaterials shallberemovedawayfromsiteimmediatelyonhisown Thecontractortogive rebateinratesagainstmaterialsandscrap/debrisfromsuchdismantledwork whichshallbecontractor'sproperty
5)Forallearthworkitems,thecontractorshouldcarefullystackallexcavated materialatsiteaspertheinstructionsoftheConservationArchitect Alldebris associatedwiththeearthworkshouldhoweverbedisposedoffbytheContractor
6)Themeasurementofexcavationshallbetakenincum asperrectangular trenchofbottomwidthofconcretemultipliedbyverticaldepthoffoundationfrom groundeventhoughcontractormighthaveexcavatedwithslopingside/fulllength trenchforhisconviency
Surfaceexcavationandexcavationforretainingwalls,basement,watertanks, effluenttreatmenttanks,etc includingbackfillingofapprovedexcavatedmaterials infoundations, &behindretainingwallsaftercompletionofwaterproofingetc wateringandconsolidating,cartingawaysurplusearth, includingpreparingthe surface (Note:Allbackfilling&spreadingofearthshallbecarriedoutinlayersnot exceeding200mmandcompactedto90%ordinaryproctordrydensity) 350 CUM
Fillinginplinthandinotherplaceswithapprovedmurumbroughtfromoutside, includingwateringconsolidatinginlayersnotexceeding200mmby8-10tonnes roadrollerorotherapprovedmechanicalequipmentetc completeasdirected
Anti-termitePreconstructionTreatment:(AsperIS:6313Part-III)(Note: Anti-termitetreatmentshallbecarriedoutthroughspecialisedagencyreputedin PestControltreatmentandapprovedbytheArchitect Thecontractortogive10 yearsguaranteeonasuitablebond)
Providingpost-constructionalanti-termitetreatmentbydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion,wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC,ISIapprovedconforming(IS8944),Includingtreatmentofwoodfor termites,borers,wetrotsanddryrots Coveredfloorareashallbemeasuredfor payment ( )
Providing,chasing,inserting/layingDampproofcourse50mmthickM-20cement concretelayerandbitumenusingcementwithapprovedwaterproofingcompound attherateof1Kgper50kgofcementetc complete
Note:
1)TheitemsgivenbelowshallbeasperSectionB"Concrete-Plain&Reinforced" ofthespecifications
2)ForsmallconcreteonapprovalofConservationArchitect,weighbatched concreteasperdesignmix,inmanuallyormechanicaltypeoperatedweigh batcherdialtypeormechanicaltypeofminimumcapacity650Kgsshallbeused Weighbatchershallbecalibratedregularly
1
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units MEASUREMENT
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units a1 A EARTHWORKANDMETALPACKING a1 a2 a3 a4 TOTAL a7 B CONCRETE-PLAIN&REINFORCED
SHEET
350 CUM
300 SQ M
SQ M
SQ M
58319 -48096 -8174 -83413 -- -24791 -- -20411615 168336 24522 83413 24791
MEASUREMENT SHEET
3)Forallmajorconcretepours,Contractorshallusereadymixedconcrete(RMC) ofUnitechPrefabLtd orM/s Larsen&ToubroLtd approvedAgencies Only53 gradecementshallbeusedinRMC Aggregatepropertiesandgradingdesign mix,quantityofsuperplasticiser,settingtime,amountofslumpatthepouringsite shallbegotapprovedbeforeitsuseineachmajorconcreting
4)Concretemixproportionwillbebasedon50kg weightofcementbags deliveredatthemixer
5)TheContractorisentirelyresponsibleforthedesignofconcretemixes The designishowever,tobeapprovedbytheArchitect
6)ConcreteM-20/20meansconcretemixM-20gradeusingmaximumsizeof coarseaggregates20mm
7)Shuttering,formwork,centeringshallnotbepaidseparatelyandshallconform toSection-C
8)Curingcompoundmaybepermittedonlyforinaccessiblelocations
9)OnlyRiverSandshouldbeused Washingofsandinrotaryscrewtypewashing machinesisamust
10)RatesshallbeinclusiveofcostofSuperplasticiserofapprovedqualityandof approveddosage
11)Ratesshallbeinclusiveofprovidingpockets,holes,inserts,pipes,etc
12)Mechanicalvibrators,internaland/orexternaltobeused
13)AlldefectiveconcreteifapprovedbyArchitect,shallberepairedbythe contractorathisowncost,usingapprovedepoxymortarorPolymermodified mortarasperManufacturer'sspecifications
14)Therateshallincludethecostofapplying2coatsofpolymerbondingagenton allsurfaceofoldornewconcreteatconstructionjointpriortoconcretingagainst thesame
15)Useoffinesandwithpropergradingisamust
16)Screeningofmetal-IandIIforremovingexcessiveflakyunderandoversize material,stonedustetc isamust
17)Onlyapprovedmouldreleasingagentshouldbeused
18)Cleaningofshutteringplatesbymechanicalbuffingaftereveryuseisamust
19)Allconcretesurfacesshallbeformfinished
20)Whereplasteringisspecified,concretesurfacesarerequiredtobehacked immediatelyaftertheremovalofformworkasdirectedbytheArchitectwherever required Additionalrateshallnotbepaidtocontractorforhacking
21)Contractorshouldmakearrangementfortablevibratorforcastingthecover blocksofrequiredsizeandgrade
22)Rateshallbeinclusiveofprovidingcoverblocks Coverblocksshallbemade ofthesamegradeofconcreteofstructuralmemberinwhichtheblocksaretobe used
23)Alljointsinshutteringshallbesealedbyuseof5mmthickcompressible materialgasketsandfixingagent
24)Constructionjointshallbeminimuminnumbersandtheirlocationshallbe approvedbytheConsultant Constructionjointsshallbetreatedproperlywith bondingcoatofapprovedmaterialtobeappliedattheoldconcretebefore commencingthefreshconcretingoperations
25)Informfinishsurfacesthepatternstobeprovidedfortheformworkshallbeas perarchitectssuggestions
26)Allsack-rubbedsurfaceshallbesackrubbedwithwhitecementofsuggested proportionasperArchitectsapproval
27)Allconcealeditemslikeconduits,junctionboxes,fixturesetc shallbelocated asperdetailsandlocationstobeapprovedbeforecasting
NotesforFormwork:
Note:1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications
2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping
3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework
4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed
5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorathiscost
6)Ratesquotedshallbeinclusiveofallformworkatalllevels
7)Rateshallincludeuseof5mmthickcompressiblegasketmaterials fixingagent adhesivetapeandmechanicalbuffingofshutteringplates
8)Onlyapprovedmouldreleaseagentshouldbeused
9)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust
10)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork
11)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect
12)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately
13)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect
2
Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr No
MEASUREMENT SHEET
14)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection
15)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant
ProvidingandlayingConcreteM20/40usingRMCforall , etc includingsideformsifrequired The rateshallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads& lifts,allfloorsallchargesrequiredincludingtransportation,centering,formwork, compacting rougheningthesurfaceifspecialfinishistobeprovidedandcuring etccomplete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkoffloorslabon gradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes towardsplant&machinery labour allleads&lifts allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc complete (level1at-165m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level2at+015m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level3at+15m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level4at+315m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery labour allleads&lifts allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level5 at+375m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery labour allleads&lifts allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level6at+45m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation shuttering centering formworkasperconditionbelow etc complete (level7at+63m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level8at+675m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level9at+905m)
ProvidingandlayingconcreteM25/20usingRMCfor ongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes towardsplant&machinery labour allleads&lifts all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes towardsplant&machinery labour allleads&lifts all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork
-- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
3
No Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr
015
015 -- CUM
asperconditionbelow,etc complete 015 CUM
asperconditionbelow,etc
015 CUM
complete
complete 015 CUM b1* PCCworksbelowraft slab plinthbeams,foundations,ramp b2* chajja basement staircase external staircase amphitheatre facade 41669 10288 29563 9441 13309 17469 15247 9394 16553 11038 6741 1071 2283 4388 625035 1543125 443445 141615 199635 262035 228705 14091 248295 16557 1011105 16065 34239 6582
asperconditionbelow,etc
MEASUREMENT SHEET
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes towardsplant&machinery labour allleads&lifts allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc complete 015
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation shuttering centering formwork asperconditionbelow,etc complete 015
Providing&layingM30/20 usingRMCforRCCincludingpumpingforfoundation pilecaps,raftslab,column,walls,shearwalls,boxcolumn,retainingwalls,plinth beams,floorbeams,invertedbeams,slabs,staircase,droppardis,chajja, parapets,pergolas,trenchslabandbeamsinstructuralfloors,loftslabsatall levels,lintelbeams/verticalstiffenersetcincludingRCCundergroundwatertanks, septictanks effluenttreatmenttanks overheadwatertanksetccomplete Therate shallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads&lifts, allfloorsallchargesrequiredincludingtransportation,shuttering,centering, formworkasperconditionsbelowetc complete
Providing&layingConcreteM20/40,usingRMC,inalternatebaysfor includingcompacting,vibrating,curing,finishingtocorrect line&levelwiththeuseofwoodenbottomandsurfacefinallyfinishedwithbrooms asdirectedbyArchitect Jointsofandasprovidedinalternatebaysshallbefilled
ProvidingandconstructingRCCundergroundwatertankincludingexcavationinall typesofsoil refillinginsidesoftank trimming dressing leveling stackingand
i)Rubblesoling230thk
ii)PCC M20/30belowraft
iii)M-25/20RCCworkinraftslabs,sumpbase,beams,RCCwalls,columns,top slabsetc includingunwrotshutteringtoRCwallsatalllevels
iv)TMTreinforcement
v)Waterproofcementplastertoinsideofwatertanks
vi)BoxtypewaterproofingtreatmentforraftandwallsofUGtank
vii)Patentedcementbasedwaterproofingtreatmenttotopofslabs
viii)50mm thk IPStoraftslab
ix)Providingandfixingcastironmanholecovers2nos 600mmdia withlocking arrangements
x)PVCwaterstop150mmdia;embeddedintakeandoutletpipesetc
Providing,erecting,fixingandcommissioningSintexorapprovedequivalent doublelayeredtanksonoverheadelevatedpedestalasdirectedincluding scaffoldingallalliedplumbing,valves,stopcocks,MCGMcertifiedwatertankcap, includingcleaningetc
Notes:
1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications
2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping
3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework
4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed
5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorat hiscost
6)Rateshallincludeuseof5mmthickcompressiblegasketmaterials fixingagent adhesivetapeandmechanicalbuffingofshutteringplates
7)Onlyapprovedmouldreleaseagentshouldbeused
8)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust
9)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork
10)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect
11)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately
12)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect/consultants
4
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units
CUM
CUM
a)RaftSlab 030 -- CUM b)RaftColumns 300 -- CUM c)RaftExternalRetainingWalls 300 100 CUM d)RccColumns CUM
withbitumenetc allcompletetothesatisfactiontotheArchitect 100 -- SQM
disposalofsurplussoilandincluding: 1000 180 -- CUM
Litres
UGtankcapacity
completeasperthesatisfactionoftheArchitect 314 189 Litres
amphitheatre internal staircase b3 b8 plinth protectionandpaving b9* b11 C
5047 1157 38383 596 1553 7207 15000 200 10000 75705 17355 115149 1788 4659 21867 72065 18
FORMWORK
MEASUREMENT SHEET
13)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection
14)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant
Notes:
1)TheitemsgivenbelowshallbeasperSectionD:'Reinforcement'ofthe specifications
2)CoverblocksshallbeofgoodqualityconcreteM30/10andshallbevibratedon atablevibratortoreducethepermeability
3)Whereverweldingofreinforcementisspecified thesameshallbecarriedout conformingtoIS:9417orIS:2751 Weldingshallbecarriedoutbyapproved qualifiedweldersonly Onepercenttestingofweldsshallbecarriedforalltypesof welds
4)Overweightofthesteelshallnotbeconsideredforcalculatingconsumptionand paymentpurpose IS constantforweightofdifferentdia ofbarsshallbe consideredforpaymentaswellasconsumptionpurpose
5)Columnreinforcementbarsarerequiredtobelappedinthemiddleportionof columnsasperIS13920 Properarrangementshallbemadetosupport reinforcementprojectingabovefloorlevel Similarlylapswithinadistanceof2D (depthofbeam)or1/4spanfromthefaceofthecolumnarenotallowed The overhangingbarsshouldbeproperlysupported Thecostoftheseworksis deemedtohavebeenincludedintherate
ProvidingandfixinginpositionmildsteelreinforcementofTATA/Vizag/SailSteel ofvariousdiametersforRCC piles,pilecaps,footings,foundations,slabs,beams, columns canopies staircases dowels chajjas lintels pardis copings fins arches etc asperthedetaileddesigns,drawingsandschedulesincludingcutting, welding,bending,hookingthebars,bindingwithGIwiresandconcretecover blocksetc complete Noseparatepaymentforchairs,laps,wastageandbinding wirewillbemade
Sameasitemd1abovebutforProvidingandfixinginpositionhighyieldstrengths deformedbarreinforcementofTATA/Vizag/SailSteelwithyieldstressnotless thanFe415ofvariousdiametersforRCC piles,pilecaps,footings,foundations, slabs beams columns canopies staircases dowels chajjas lintels pardis copings,fins,archesetc asperdetaileddesignanddrawingscheduleincluding cutting,bending,hookingthebarsbindingwith18SWGGIwiresincludingwelding andsupportingasrequiredandprovidingconcretecoverblocksatalllevels includingallleadsandliftsetc complete Noseparatepaymentforchairs,laps, wastageandbindingwirewillbemade
Sameasitemd2above,butforTMTSteelReinforcementofTATA/Vizag/Sail Steel
StainlessSteel304screws nails bolts fasteners etc forallrepairworks
Supplying fabricating erecting aligninginposition fixing StructuralSteel ofTATA /Vizag/SailSteelinalltypesofmembers(Box,Ropes,I-sections,C-sections, L-anglesetc)forColumns,Beams,TrussRafter,Purlinforroofs,lofts,stairs, mezzanines,storageracksforparaffinboxes,portals,braces,underpinning, shoring,frames etc Theratetoincludecutting,anchorfasteners,bolting, welding wastageandapplicationofepoxybasedpaints(Asianmake)asper manufacturer'sspecificationsandasdirected Therateshouldincludepaintingof thesteelasstatediniteme5below METRIC TON
COLUMNS-ISMB250
CIRCULARSTEELHOLLOWCOLUMN-NB200M
Providingfabrications erectingandfixingSS Railing
i)SS PoleMadein16gauge50mm DiameterISapprovedSS304pipewitha ornamentalSSringatthebottomendsSS topatapexforassemblyofupper
Handholdpipewholeunitprovidedwithmirrorfinish (Foraheightof12M)
Note:
Measurementshallbetakenforcompletelaidroofinsquaremeter Overlapswill notbepaidextra Therateshallincludeallthematerial labourbolts nut washers andtoolsandplantsetc complete SteelFramedRoofingSystem
13836 -- kg
5
Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr No
LengthinPlan InclinedLengthinSection D
d1* d2* d3 d4* E
e1 e11 F ROOFING
Forthepurposeofthiscourseanapproximateamountisbudgeted 7402185 088218 3459 000
REINFORCEMENT
STRUCTURALSTEELWORKSANDOTHERFABRICATIONITEMS
ThisitemisworkedoutbytheStructuralConsultant
MEASUREMENT SHEET
ProvidingandfixingofSteelFramedRoofingSystem ExternalSheet:Klippon/ SteellockAZ150SMPcolourcoatedGalvalumein058mmTCTandincluding screwsandclips InternalSheet:Hi-Rib/HispanAZ150BareGalvalume/SMP colourcoatedGalvalumein047mmTCTincludingscrews Insulation:Supply andLayingof50mmthicklogfiberresinbondedfiberglassrollinsulation16kg/m3 densitytobefixedbetweeninternalandexternalsheets SubGirt:G I Purlins40 x50x40mmx16G(16mm)galvanisedsteelfixedtopurlins/girtwithselfdrilling fastenersatmax 500mmcentersandsteelbaseplatesofsizes150x150x6mm
BOXSECTION25x50mm
BOXSECTION100x50mm
Providingandfixingofflashingofallsizesforf1above
ThisitemisworkedoutbytheConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
Providing,supplyingandinstallingcellular(doublewalled)polycarbonatesheet/ tetrapacksheet(dupontorequivalent)/GISHEETroofinginclusive offixingto structuralsteelsupportsystemasperdesignandmanufacturer'sspecification
Thecostshallbeinclusiveofalltaxes Allnecessaryscaffolding craneand accessoryworktobeusedincarryingouttheworksistobeincludedinthecost Thecontractorshallhavetotakeduecareofthesurroundingbuildingandseetoit thatthefacadeskinanditselementsarenotdamagedintheprocessofcarrying outthiswork SQM
G MASONRYWORK
Note:
1)Theitemsgivenbelowshallbeasper MasonryWork ofthespecifications
2)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction
3)CementformanufacturingconcreteblockstobeprovidedbyContractor
4)Onlyselfsupportingscaffoldingwillbeallowed,noholesinmasonrywouldbe permitted
5)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc
6)Factoryincludingblockmakingmachineformanufacturingofconcreteblocks shallbeapprovedby Architect-in-charge
7)Thecementforblockmasonryshallconfirmtotherequirementofminimum cementrequirementforPCC ofconcretespecifications
8)Requiredquantityofconcreteblocksaretobemanufacturedwithgroovesto accommodatetheconduitpipes/waterpipesetc Thegroovesshouldbestaggered onbothsides
9)Therateforconcreteblockmasonrywallsshallbeinclusiveofproducinghalf blocksandoddsizedblockstosuittheconstruction
10)Mortarsforallmasonryworkshallbemixedinanapprovedmortarmixeror concretemixer
11)Handmixingofmortarwillnotbeallowed
12)Onlyriversandand43gradecementshallbeused
13)Washingofsandinrotaryscrewtypewashingmachinesisamust
14)Bricksusedshallbeoffirstclassandshallbeofregularinshapeandtheir edgesshouldbesharpandshallbefreefromcrack Brickshallbefullysoakedin cleanwaterbysubmerginginatankforaperiodof12hoursimmediatelybefore use
15)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc
LengthofRunningWall
Providingandlaying
230mmthickbrick(firstclass)masonrywall
in1:6C:M aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins,columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
150mmthickbrick(firstclass)internalmasonrywall
Providingandlaying in 1:6C:M aboveplinthoratalllevelsincludingforoddshapedwalls brickfins columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
100mmthickbrick(firstclass)internalmasonrywall g7* PCC/stonecoping
Providingandlaying in 1:6C:M,aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins, columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
Providingandfixing overterraceparapethavingdimensions 330mmwide100mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
6
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units f1 ROOF f2
g5
-- SQM
metricton
metricton
- SQMT
SQMT
RUNNING MT 000 000 000 000 17608 000 28613 11774636 16348347 28613 589828 365375 104321 17608
SQMT
MEASUREMENT SHEET
Providingandfixing loverterraceparapethavingdimensions 230mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1450mm
b)2300mm
c)950mm
d)1500mm
e)3725mm
ProvidingandfixingRCCLintelsandSilloverterraceparapethavingdimensions 150mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1100mm
b)1450mm
c)1650mm
d)1250mm
e)950mm
f)1500mm
ProvidingandfixingRCCLintelsandSilloverterraceparapethavingdimensions 100mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1100mm
b)1450mm
ProvidingandfixingRCCLintelsoverterraceparapethavingdimensions230mm wide230mm thicknessinpiecesof600mmlengthoveramortarbeddingofCM
1:6/Limemortar1:3
a)3725mm
ProvidingandlayingBB cobainallpositionssuchasplinthsandramp
Notes:
1)Theitemsgivenbelowshallbeasper'Plasteringofthespecifications
2)Scaffoldingforplasteringshallbeofselfsupportingtype Holeswillnotbe allowed tobemadeinthemasonryorRCCworkforanchoringthescaffolding
3)OnlyRiverSandshouldbeused Howeverwashingofsandinrotaryscrewtype washingmachinesisamust
4)Mortarforplasteringworkshallbemachinemixedinamortarmixerorconcrete mixer Handmixingofmortarwillnotbeallowed
5)Therateforplasteringshallalsoincludeprovidingandmixing/applyingan approvedbondingagentasperdirectionofArchitect-in-charge andalsoapplying approvedhack-aidonsurfacereceivingplaster
6)Only43gradecementshallbeused
7)Rateshouldbeinclusiveofscaffoldingandcuringshallbestartedassoonas theplasterhashardenedsufficientlynottobedamagedwhenwatered Theplaster shallbekeptwetforatleast10days
Providing12mmthickInternalcementplasterintwocoatsincementmortar1:4 with/withoutneeru,finished smoothforallRCC/brickblockmasonrywork includingcuring andscaffoldingetccomplete
Providingandapplying18mmthickcementplasterincementmortar1:4 without/withneerufinishedsmooth forRCC/brick/blockmasonrycompleteinall respectsincludingscaffolding,bondingagent,curingandasdirectedbyArchitect
Providing&applyingacontinuouscementplasterdripmouldofsize50mmwide and15mmthickunderRCCpardi,chajjaandaroundwindowopeningsatalllevels includingnecessaryscaffolding,stagingetc andcuringcomplete
Notes:
1)Theitemsgivenbelowshallbeasper'Paintingofthespecifications
2)ScaffoldingforPaintingshallbeofselfsupportingtype Holeswillnotbe allowed,tobemadeinthemasonryorRCCworkforanchoringthescaffolding
3)ThebrandsofthePaintshallbespecifiedandreadymadepaintofrequired shadeshouldbeused
4)Thesurfaceshallbemadeperfectlysmoothbyrubbingwithsandpaperof differentgrades
5)Allholesandopenjointsshouldbefilledwithstrongputtyorwithamixtureof glueandplasterofparisandsmoothenedbyrubbingwithsandpaper
6)Insteelwork,allscales,dirt,suppliersdeliverymark,oil,greaseetcshallbe removedwithsandpaperbeforepainting Specialcareshallbetakenforcleaning thecorners
7
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units g9* RCCLintelsandSil g*10 H
h1* h2 h5* J
PLASTERING,POINTING
PAINTING
-- -- CUM
CUM
CUM
CUM
CUM
-- -- SQMT
-- -- SQMT
-- -RUNNING MT
372 150 036 026 4736 133453 110957 000 372 15 0357 0257 4736 133453 110957 30474
MEASUREMENT SHEET
7)Eachcoatsshallbeallowedtodryupperfectlybeforethesucceedingcoatis laidoverit
8)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction
Providingandapplying3coatsoveracoatofprimer,ofoilbounddistemperof approvedshadeandofapprovedmakeoverconcrete/plasteredsurfaces includingpreparingofthesurfaces,scaffoldingetc completeinallrespects
Providingandapplyingacrylicemulsionpaintofapprovedquality,finish,colourand shadetooldandnewsurfacesinthreecoatsincludingpreparingthesurfaces applyingprimer,putty,etc complete
Notes:
1)Theitemsgivenbelowshallbeasper'Flooring'ofthespecifications
2)Atleast6samplesforallfinishingitemsofwork,fromdifferentapproved sourcesshallbesubmittedbeforestartingtheworkforapproval Architectin chargedecisionregardingtheshade,qualityandthesourceisfinal Alllike materialsofflooring cladding etctobefromsamebatchasperapprovedsample
3)Rateshallbeinclusiveofallexposedstone/tileedgestobechamfered,hand polishedandmouldedasdirected
4)Ratesforverticalcladdinginstoneofthicknessfrom6mmto25mmshallinclude exposedrightangularcornerjointsfinishedandedgespolishedandmouldedas perArchitect'sinstruction withcutting6mmgroovesandalsoedgepreparationto suitcornerangles
5)Skirting/dado/cladding,becauseofvaryingheightwillbemeasuredandpaidon squaremetrebasisinsteadofonrunningmetrebasis
6)Therateforflooring/claddingshouldbeinclusiveofbedding/backcoatas specified Thethicknessofmortarbeddingorbackcoatspecifiedisminimum Thisthicknesswillvaryaccordingtothethicknessofflooringorcladdingmaterial soastosuitthespecifiedlevelorline TheContractorshallberesponsiblefor properbondingbetweenbackingcoat&masonryworkorRCCworkandhisrate shallbeinclusiveofprovidingandapplyingapprovedbondingagent
7)Forallverticalcladding,anapprovedchemicaladhesivefortilesasper manufacturer'sinstructionsshallbeusedandtheratesquotedshallbeinclusiveof thecostofthisadhesive,forathickness3mmto4mm
8)Unlessotherwisespecified,allsizestobeinmetricsystem
9)Scaffoldingforexternalcladdingshallbeofselfsupportingtype Holeswillnot beallowedtobemadeinthemasonryorRCCworkforanchoringthescaffolding
10)Therateforverticalcladdingshouldalsoincludetheworkonisolatedcolumns chamfers,etc
11)Noseparatepaymentwillbemadeforprovidingandfixing,oddsizedtilesof anyshapeandsizetosuitconsultantrequirement
12)White/ColouredcementwithmatchingpigmentsorJohnsonBALgroutwith appropriatecolourshallbeprovidedbyContractorathiscost
13)TheContractorshallprovidesuitablesupportsforsupportingthecladdingtiles andremoveitonlyafterthetileshavefirmlyadheredtoitslocation
14)Edgesofcladdingtilesfixedonthecornersofthecolumnsandwallsshouldbe polishedasperdirectiveofArchitect,orasindicatedinthedrawings
15)Themaximumthicknessofthepastepreparedbyusingtileadhesiveand appliedonthewallandcolumnsurfacesshouldnotbemorethan3mm Contractorshallhavenoextraclaimsonaccountofincreaseinthethicknessofthe pastebeyondmaximumthicknessasspecifiedaboveduetofaultyworkmanshipor anyotherreason
16)Mortarrequiredforbedding/backcoatshallbemixedmechanicallyinmortar mill Onlyriversandshallbeusedinthemortar
17)Allfixtures,electricalpoints,lightsetctobealightedwithtiling,groovesand pattern flushwiththewallfaceasperdetailsanddrawings Amockupforthe sameshallbegotapprovedfromArchitect
18)Thecontractorsarerequiredtostudydrawingscarefullytounderstandfixing detailsofflooring,skirting,claddingetc,tokeeprequiredgroovesbetweendifferent finishesatdoorandwindowlocationsflooringandskirtingjunction,wallandceiling junctionetctomatchflushlinei e verticalplaneofwallandskirtingetc
19)Rateshallbeinclusiveofcostofscaffolding,grouting,curing,finalpolishingby non-slipwaxpolishandcleaningofsurfacesandalsodewatering&keeping surfacedryduringconstruction
20)Asample/mockupofflooring,cladding,etctobegotapprovedfrom,Architect
21)Alladditionalgroovestobeprovidedinvertical,horizontalanddirectionas shownindetaileddrawingsorasdirected
22)Tomakewallcladdingsurfaceandskirtingsurfaceflush wallatskirtinglevel shallberequiredtorecessinsideasperfixingdetails Thenecessaryrecessesin RCCwalletcshallbetakenatthetimeofconstructionitself
23)Only43gradecementshallbeused
8
Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr No
-- -- SQMT
-- -- SQMT
j1* j2* K FLOORING&PAVING&SKIRTING 122915 110957 122915 110957
MEASUREMENT SHEET
Providingandlaying15-32mmthickhandcutandmirrormachinepolishedgreen squareorrectangularrangingfrom200mmx200mmupto 600mmx600mmfinishedsizeandofapprovedcolourandshadeinsmaller patchesforrepairorinlargerareasincluding20mmthick1:2limemortarbedding or1:6cementmortarbedding,tobecompactedproperlybysuitablemethodas approvedbytheArchitect,beforelayingKotahstoneinposition Jointsfinished withneatcementslurry widthofjointshallbebetween10mmto150mmlayingas perdesign,including3coatsofmachinepolishingafterlaying,curing,cleaning completeasdirected
Sameasitemk2abovebutforrisersandtreadswithmouldingfornosing,antiskid groovesetc complete
-Do-sameasinitemNo ofheightbetween 100mmto2000mm,mirrorpolishedandmachinecut15mmthickkotahstone,and sizetomatchthejointsinflooring,etccomplete
Providingandlaying25-32mmthickhandcutandmirrormachinepolished
squareorrectangularrangingfrom200mmx200mmupto 600mmx600mmfinishedsizeandofapprovedcolourandshadeinsmaller patchesforrepairorinlargerareasincluding20mmthick1:2limemortarbedding or1:6cementmortarbedding,tobecompactedproperlybysuitablemethodas approvedbytheArchitect beforelayingKotahstoneinposition Jointsfinished withneatcementslurry,widthofjointshallbebetween10mmto150mmlayingas perdesign,including3coatsofmachinepolishingafterlaying,curing,cleaning completeasdirected
Sameasitemk6abovebutforrisersandtreadswithmouldingfornosing,antiskid groovesetc complete
ProvidingandfixingWhite/ceramicantiskidtiles{Kajaria,Johnson,somanyor approvedequivalent}200x200mmto400x400mminsizeandminimum6mm thickfordadooftoiletsinrequiredpositionlaidonabedof1:4cementmortar plasterof15mmthicknessincludingneatcementbacking,fillingjointswithwhite cementslurry,curingandcleaningcomplete (BasepriceoftileRs400/Sqm)
Providingandfixingwhiteceramictiles( ){Kajaria Johnson somanyor approvedequivalent}200x200mmto400x400mminsizeandminimum6mm thickfordadooftoiletsinrequiredpositionlaidonabedof1:4cementmortar plasterof15mmthicknessincludingneatcementbacking,fillingjointswithwhite cementslurry,curingandcleaningcomplete (BasepriceoftileRs500/sqm)
Providingandlayingfullbody8mmthick ofRestile/ Pedder/Johnson/Nitcooranyapprovedmakecolourorofsize150x150/200x 200/300x300/400x400/600x600/900x900mminclusiveofbeddingof CM 1:4,forlocalisedrepairsorinlargequantities,forflooring/skirting/dado, andwithcementfloatandJohnsonbalgrout
-Do-sameasinitemNok9abovebutforskirting/dadoofheightbetween100mm to2000mm,mirrorpolishedandmachinecut15mmceramicvitrifiestiles,andsize tomatchthejointsinflooring etccomplete
Providingandlayinginrequiredpositionchinamosaicflooringoverconventional waterproofingtreatmentoratgroundleveloverPCCorIPSbaseofapproved colourandpatternon40mmthickbeddingof1:4cementmortarincludingneat cementfloat,givingproperslopes,compaction,curingetc complete
Sameasabovebutforwashbasincounters
Notes:
1)CarpentryandJoinery,Timber,Steelcasement,AluminumDoorsWindows, skylightsopenable slidingwindows rollingshuttersandpolycarbonatesheet curtainwalls,etc
2)Forallaluminumworks thecontractorshallsubmitshopdrawingforeachitem ofworkindicatingthesectionofaluminum,itsweightandjoinerydetailandtotal weightofwindow/door/partitionwallsetc Whereverpossiblerivetingshallbe resortedtoforconnection Alternativelyhotdippedgalvanizedpinheadedsheet metal/brass screwscouldbeused Nomildsteelwithouthotdippedgalvanizing shallbeusedforanyfastenings,etc
3)TheratesshallnotbepaidseparatelyforAluminumsectionsusedonweight basis
4) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials neoprenerubbergaskets screws,etc
5)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
6)Alljointsbetweencivilworkandaluminumframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
7)Ratesforrepairsaswellasprovidingandfixingofnewdoors windows sky light,rollingshutters,etc inthissectionshallbeinclusiveofalltheitemsof hardware/fittingsandnoextrashallbepaidtothecontractortowardsthecostof hardware/fittings
SQMT
9
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units k2 kotahstoneflooring k3 k5 k2abovebutforskirting/dado k6 sandstoneflooring k7 k7* k8* dado k9 CeramicVitrifiedtiles k10* k12 M DOORS,WINDOWSANDPARTITIONS
-- -- SQMT
-- -- SQMT
RUNNING MT
-- --
-- -- SQMT
-- -- SQMT
RUNNING MT
-- -- SQMT
-- --
RUNNING MT 54280 4065 10341 10538 15106 23591 720 54280 4065 306991 5304 102587 10341 10538 15106 78658 23591 720 SQMT SQMT
MEASUREMENT SHEET
8)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:
9)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)
10)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand
11)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)
12)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized
13)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete
14)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor 'DORMA'TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect
15)BrassoxidizedBabylatches,75mmlongwith25mmx8mmthickboltcomplete withknob Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal
16)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release
17)PlainMorticelocks6leversLatchBoltofGodrejmakeequivalentwithbrass bodyandchromeplatedflatplatetoedgeofdoorincludingfixingtotimberor aluminiumshutterframesetccomplete
18)Sameasaboveitem(16)butwithdeadlock
19) 3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)
20) Doorbufferwithrubber/PVCbushshutterorwallmounted
21)Providingandfixing andrepairrateswillalsobeinclusivealdrops,handles stopperetc allcomplete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timberdoubleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc
Glassdoubleleafpivotdoor
Providingfabricatingandfixinginpositionaluminiumframecomprisingofopenable opaqueglassshutter(lockinghandlesandpullhandlesforshutter,withfloor springforrotation)includingmaskingofjamsbeforecompletionofworkdemasking
10
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units
2100x800mm 2500
2100x1150mm 1000
2100x1350mm 200
2100x950mm 900
complete
ofcompletioncleaning 2400x2000mm 100 HPLsingleleafhingeddoor ProvidingfabricatingandfixinginpositionogHPLdoorcomprisingoflocking handlesand dropdownbottomsealandaluminiumframe 2100x800mm 200 AluminiumOpenable2PanelSlidingWindow m1* m3 m5*
MEASUREMENT SHEET
Providingfabricatingandfixinginposition2trackcolouranodisedextruded aluminumsectionsofJindalorequivalentapprovedmakeforslidingwindows, openablecomprisingofouterframe(035kg/rm) shutterframe(050kg/Rm) glassshutter--(040kg/Rm),mullionforouterframe(055kg/Rm),locking handlesandpullhandleforeachshutter,onepairSS frictionhingesforeach shutterand5mmthickclearfloatglassModiorwiredglassorequivalent with neoprene/rubbergasketwithhinges lockingarrangementandwooden encasementwherevernecessaryincludingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan
AluminiumOpenableLouveredWindow
Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium heavysectionsJindalorequivalentmakeforlouveredwindows,openable comprisingofouterframe(035kg/rm),louveres(050kg/Rm),mullionforouter frame(055kg/Rm),rotatingknob,includingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan
Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium sectionsofJindalorequivalentapprovedmakeforfixedwindowsFixedglass
Notes:
1)Thecontractorwillgivea10yearsguaranteeoftheworkundertakenon Rs100/-Stamppaperontheapprovedformatdulyregistered
2)Tenpercentamountofvalueofworkswillberetainedfortheperiodoffiveyears fromthedateofactualcompletionofthework,willbereleasedprogressivelyat fourpercentaftertwoyearssubjecttoattendinganyrectificationofdefectsand balanceamountsbytheendoffiveyears
3)Allworktobedonethroughspecialistwaterproofingandstructuralrepair agenciesshallbeundertakenonlyontheapprovaloftheArchitect
Providingandapplying70mmto75mmthickproprietarybrandcementbased waterproofing(boxtype)forbottomRCCraftslabandsidesofRCCwallsofwater tanks,septictanks,effluenttreatmenttanks,etc including providingleakproof treatmentby injectiongrouting toconcretemembersat10mcentresinboth directionsandalsoatallconstructionjoints andprovidingandfixing20mmto 25mmthickroughShahabadstoneorotherapprovedstonetilessetin20mmthick 1:3waterproofcementmortarandfinishingthebylaying/plastering,with20-30 mmthickC:Min1:3withwaterproofcompound(Contractortogivecomplete specificationsforwaterproofingsystemheproposetocarryout)
ProvidingandlayingwaterproofinginWCandbathroomincluding inall positionconsistingofspecialisedapprovedwaterproofingcompoundandmaterial asperspecificationswithallleadandlift
Providingandlayingcementbasedwaterproofingtreatmenttoterracewithbricks batslaidinrequiredslopetodrainthewaterforanyspanaftercleaningthe base surfaceapplyingacoat ofcementslurryadmixedwithapprovedwaterproofing compoundandlayingthebrickbatsonbottomlayerinC:M1:5admixedwith approvedwaterproofingcompoundfillinguptohalfdepthofthebrickbats,curing thislayerfor3daysapplyingcementslurryoverthislayerjointingofbrickbatswith C:M1:3admixedwithapproved waterproofcompoundandfinallytopfinishingwith average20mmthicklayersofcementmortaraddedwithjutefiberat1kgperbag includingfinishingthesurfacesmoothwithcementslurryadmixedwithapproved waterproofingcompound
Thefinishedsurfaceshallbelinedwithfalsesquaresof300mmx300mmor preparingthesurfacetoreceivewhitechinamosaicflooringonit(costtoinclude whitechinamosaicflooring)andmakingthejunctionsattheparapetroundedand taperedtowardstopforrequiredheight withdripmouldatthejunctionofthe plasterandparapetincludingcuringbypondingtestetc complete Average thicknessofbrickbat200mm
WaterProofingChajja
Providingandapplyingwaterproofingtreatmentoverchajjausingproprietary cementbasedsystemlikeIndiaWaterproofingusingbrickbatsof50mmormetal no2 averagethicknessoftreatment50mm finishedwithsmoothcementfinish withfalsetilemarks,includingbreaking/removingexistingwaterproofingand cartingawaythedebrisetc complete
Tilejointfilling
Providingandfillingcementbasedtilejointsealingcompound(JohnsonBalGrout orequivalent)inbath/WC/toilet/flooringtilesincludingrakingoutoldloose jointingmaterial,curingetc complete
SQM
SQM
SQM
11
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units m12* m13* m14* N WATERPROOFING n1* n4 BB coba n5* n12 n13* n14*
20micronsetc completeasdirected 1200x1000mm 1900
20micronsetc completeasdirected 650x500mm 2500
windowcomprisingofouterframeshutterframeglassshutterandlocking arrangements 3425x470mm 200
SQM
SQM Gapssealing 38383 11604 23591 7158 98031 38383 11604 23591 7158 98031
MEASUREMENT SHEET
Providingandfillinggapsbelowdoorframes,aroundNahanitrapswith Roffe-grout-GPorequivalentincludingcleaningthesurfaceofallloosematerials curing mixingaspermanufacturer'sinstructionsetc complete
ProvidingandfixingLeadFlashing600/900mmoverChajjashallbehoused approximately300mmabovechajjainamortarjointofadjoiningmasonrywall,this sheetctshallbeslopingoutwards Fasteningdown –Thesheets,shallbe fastenedwiththebestSSorBrassscrews/boltsandleadwashersAllen’s Fisher orotherapprovedfasteningsasdirectedbytheConservationArchitect Thelead sheetingshallbegoodmilledleadnotlessthan10Kg/Sqmbenttotheshape fastenedintothewall groove20mm,withbrass/sswallhookswithjointsatright anglestotheflowbyadripwithaproperlap iflevelspermit orby75mmjointsof foldedlead
SECTION-III: CARPENTRYANDBUILTINFURNITURE
Notes:
1)CarpentryandJoinery,forpartitions,tables,cupboards,storageunits,desks, labfurniture,museumdisplayfurniture,officefurniture,auditoriumandlecture theatrefurniture doors windows skylights falseceilingetc
2)Forallcarpentryandfurnitureworks,thecontractorshallsubmitshopdrawing foreachitemofworkindicatingthesectionofwoodits joinerydetailetc Whereverpossiblewoodenpinsshallberesortedtoforconnection Alternatively stainlesssteel/brass,screwscouldbeused Noothernails/screwsshallbeused foranyfastenings,etc
3) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc
4)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
5)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
6)Ratesforrepairsaswellasprovidingandfixingofnewcarpentryitemsand furnitureinthissectionshallbeinclusiveofalltheitemsofhardwareandfittings requiredandnoextrashallbepaidtothecontractortowardsthecostofhardware/ fittings
7)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including,fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:
8)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)
9)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand
10)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)
11)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized
12)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete
13)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor DORMA TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect
14)BrassoxidizedBabylatches,75mmlongwith25mmx8mmthickboltcomplete withknob Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal
15)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release
16)PlainMorticelocks6leversLatchBoltofDorma/Godrejorapproved equivalentmakeequivalentwithbrassbodyandchromeplatedflatplatetoedgeof doorincludingfixingtotimberoraluminiumshutterframesetccomplete
17)Sameasaboveitem(16)butwithdeadlock
18)3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)
19)Doorbufferwithrubber/PVCbushshutterorwallmounted
20)Providingandfixing andrepairrateswillalsobeinclusiveofaldrops,handles stopperetc allcomplete
PartitionWalls
Providingandfixingfullheight50mmthickHPLpartitionwallsofheight2100mm includingallfixing
12
No Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr
RUNNING MT
RUNNING
MT
SQM InbuiltStoneseats SQM 11998 20675 098 2295 11998 20675 098 2295 n24* A CARPENTRY a1* E MISCELLANEOUS e1
MEASUREMENT SHEET
Providingandconstructinginbuiltmasonryandroughkotahseatsasshownin architecturaldrawingsalongwithacladdingofBluecolourterrazzo(make:Bharat FlooringsandTilesPvt Ltd -Premiumterrazzoseriesorequivalent) laidona bedof1:4cementmortarincludingneatcementbacking,fillingjointsandwhite /colouredcementslurry,curingandcleaningcomplete
StainlessSteelBenches
ProvidingandfixingperforatedSSsheet(SS304)benchofapproveddesignwith SSpipeframingand3mmthickperforatedSSsheetpanelsasshowninthe architecturaldrawingswithnecessarybolting/weldingandfixingontilesurface withanchorfastenerbolts etc complete
Steelamphitheatre
Providingandfixingwithallthebaseplatesandnecessaryjoineries,finishing STEELBOXSECTION50x50mm metricton WOODENPLANKS(100MMWIDEAND20MMTHICK) SQM
SECTION-IV: MISC
Notes:
1)Rateshallincludeminorcivilwork,scaffolding,electricalworks,dismantling, liasoningcost,steelitems,etc
2)Thequotedpriceshallbeinclusiveofcentralexciseduty,VAT,octroiandservice taxandallotherapplicabletaxes Thisquotationshallnotbesubjecttoprice variationcost
3)Thecontractorshallmakenecessaryarrangementstoprovidesuitablelockable weatherproofstoragespaceforthematerialsandshallalsostacktheexisting dismantledmaterialinasafesecureplaceforthedisposalofthemunicipal authorities
4)Thecontractorshallincludeinthequotation60monthsfreemaintenance,which willbecommencedfromthedateofcompletionofproject
5)Thecostshallbeinclusiveofallpreparatoryworkandnoextracostwillbe providedtowardsthisitem
7) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc
6)Forallworksinthissectionasspecifiedbytheconservationarchitect,the contractorshallsubmitshopdrawingforeachitemofworkindicatingthesections materials,its joinerydetailetc Whereverpossiblewoodenpinsshallberesorted toforconnection Alternativelystainlesssteel/brass,screws/boltscouldbeused Noothernails/screwsshallbeusedforanyfastenings,etc
8)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturersforapproval Architectdecisionshallbefinal
9)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
FabricationandinstallationofInformationSignasspecifiedinthedrawings Providing&fixinginposition inaluminiumextrudedbrown anodizedsectionwithlettersinvinylonbothsidescoveredwithacrylicsheetand asperapprovedsamplebyArchitectfixingasdirected
FabricationandinstallationofTreeGratingasspecifiedinthedrawings
i)Castirontreegrating,paintedwithanticorrosionprimerand2coatsof polyurethane/epoxypaintinapprovedshade,tobefixedontoconcretebaseas shownindrawings Ratetobeinclusiveofbasegrouting,providing,fixing,nuts, bolts,welding,painting,etc complete
ii)GraniteStonecobblestoneedgingaroundthetreebase,withwhiteround pebbles/withgravelbedinsideasindicated
SECTION-V: ELECTRICAL
ThisitemisworkedoutbytheElectricalConsultant
Forthepurposeofthiscourseanapproximateamountisbudgeted
Supply,Installation,TestingandCommissioningofEarthingstationasperIS3043 consistingof40mmGI3000mmlongpipe suppliedwithfunnelattopincluding saltcharcoal,masonrychamber,testlinkbox,hardwareincludingexcavationand masonryworkwithcastironcoverforthechamber
Supply&Layingof followingsizesofstrips &wiresfromearthingchamber/Gridto theelectricalequipment&terminatingthesame Theportionofthestripunder groundshallbelaidatadepthof600mmandonsurfaceshallbefixedwith spacers&clamps&alsoonTray Excavation&allcivilworktobeincluded 25mmx3mmGI stripforDistributionBoard(FirstDistributionBoardinacluster ofDistributionBoards)
8SWGGI EarthingwireforLighting&PowerDistributionBoard
Supply,Installation,testing andcommissioningof3phaseenergymetersuitable forunbalanceloadandincludingnecessarycutoutandjumperwiresetccomplete aspersupplycompany'srequirement
100
13
No Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr
e3* e4* 3* a) signageboard 4* 1 EARTHING a 2 EARTHINGSTRIPS/CONDUCTOR a b 3 METER a 05152 2293
300
MEASUREMENT SHEET
Supply,Installation,testing andcommissioningofTPNMCB16A andincluding ncessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement
Supply Installation testing andcommissioningofTPNMCB40A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompanys requirement
Supply,Installation,testing andcommissioningofTPNMCB32A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompanys requirement
Supply&InstallationofstandardmanufacturersDistributionBoardforLighting It shallbeastandardBoardwithdoubledoor&suitableforrecess mounting&shall beasfollows Scopeincludesmountingarrangementincludingnecessarysteel, hardwareetcWiresinDB tobeproperlydressedwithbuttontapeandwithlugs labelsetc
Incomer40ATPNMCB-1No 40A,30mA,2P,RCBO-3NosOutgoing 6/10ASP MCB-24Nos
Supply,Installation,Testing&CommissioningofPVCArmouredCablefixedto walls,Ceilingswithclamps,spacerssaddlesorlaidinreadymadetrenchortiedto cablestraywithcableties,tagsetc asfollows 1100VgradeasperIS
Installation Testing&Commissioningofcables(onwalls trays) PVCinsulated 1100Vgrade,steelarmoredasperIS1554withlatestamendmentincluding spacers,saddles,tags, etcThecablesto beproperlydressed
4Cx16SqmmALAYFY
3Cx10SqmmALAYFY
4Cx10SqmmAYFY
3Cx4SqmmAYFY
3Cx6SqmmAYFY
3Cx25SqmmAYFY
TerminationofcableswithHeavydutySiemenstypeglands&lugs Lugsused shouldbeCopperforcoppercables&Aluminiumforaluminiumcable Scopeto includeallmaterial&labourincludingpropertools Insulationtape
4Cx16SqmmALAYFY
3Cx10SqmmALAYFY
4Cx10SqmmAYFY
3Cx4SqmmAYFY
3Cx6SqmmAYFY
3Cx25SqmmAYFY
Pointwiringforlight,bellpoint ScopetoincludecircuitWiringforlighting&the lightswitchboardwithswitches&furtherwiringtolightpoints Theswitchboard shallberecessmounted/surfacemountedofGIstandardasperthesupplier The pointWiringshallconsistof3x15Sq mmcopperwire,PVCinsulated,1100V gradeinPVCconduit/PVCcasingcaping Thewires&conduitsshallrunfromthe switchboardtotheindividualpoint&circuitwiringshallbeof3x25mm2copper wirefromdistributionboardtothe switchboard Modularplatetypeswitchestobe used6ASwitchSocketonswitchboardtobeincludedInmajorityofthecasesthe lightsaregroupswitchedfromtheDistributionBoardinwhichcasethewireshall be3x25mm2 AllwiresshallbeFRLS
PrimaryLightPointwiringofaveragelengthupto5meterslengthofwire
PrimaryLightPointwiringofaveragelengthupto55to10meterslengthofwire
PrimaryLightPointwiringofaveragelengthupto105to15meterslengthofwire;
PrimaryLightPointwiringofaveragelengthupto155to20meterslengthofwire;
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto5metersof lengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto55to10 metersoflengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto105to15 metersoflengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto155to20 metersoflengthofwire3x15sq mmwires
FanpointwiringshallbesameasPrimarylightpointpointwithindividual controlWireofsize3x15sq mmsizeshallrunfromtheswitchboardtothefan pointthroughPVCconduit/PVCcasingcaping ThecircuitfromtheDBtothe switchboardshallbe3x25sq mmwiresSpaceforregulatortobeprovidedinthe switchboard Upto5Metersof lengthofwire
FanPointwiringwiringlength55to10meterlength
FanPointwiringwiringlength105to15meterlength
FanPointwiringwiringlength155to20meterlength
Exhaustfan/WallFanpointswiringshallbesameasPrimarylightpointwith individualcontrol&6Asocket&top@thefanpoint Wireofsize3x15mm2size shallrunfromtheSwitchBoardtothefanpointthroughconduit Thecircuitfrom theDB totheSwitchBoard with3x25mm2wire
14
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units b c d 4 DISTRIBUTIONBOARD a 5 CABLES&TERMINATIONS a b c d e f 6 TERMINATIONOFCABLE a b c d e f 7 POINTWIRING ai aii aiii aiv bi bii biii biv ci cii ciii civ d
(LDB)
MEASUREMENT SHEET
Pointwiringfor6Ampswitchsocketpoint Scopetoincluderunningof3x25mm2 copperwire,PVCinsulated,1100VgradeinPVCconduit Wirestoberunfromthe PowerDistributionboardtotheIndividualsocketsupto4socketscanbeloopedon onecircuitWorkstationRawpowerAllwiresshallbeFRLSWiringlengthupto5 meters
6Asocketpointwiringlength55to10meters
6Asocketpointwiringlength105to15meters
6Asocketpointwiringlength155to20meters
Pointwiringfor6/16Amp switchsocketpoint ScopetoincludecircuitfromDB toindividualpoints Conduit,accessories&wireswith3x4mm2copperwiretobe laidfromDBtoindividualsocket TwosocketpercircuittobeconsideredAllwires shallbeFRLSWiringlengthupto5meters
6/16APointwiring55to10meterlengthofwire
6/16APointwiring105to15meterlengthofwire
6/16APointwiring155to20meterlengthofwire
6/16APointwiring205to25meterlengthofwire
Supply,Installation,Testing&Commissioning6Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections
Supply,Installation,Testing&Commissioning6/16Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections
Supply,Installation,Testing&Commissioningof20AReyrollPlugsocketwith3pin MetalTop,inmetalboardwith20ASPMCB
Supply,Installation,Testing&Commissioningof225mmDia ExhaustFanwith connection
Providingandinstalling connectingandcommissioning32ATPNSFUwithHRC Fuse
ProvidingandlayingTwopairTelephonecableinexistingconduit/casingcaping
Providingandinstallingoutlet fortelephonecable
Providingandinstallingcelingfan1200mmsweepwithfivestepselectronic regulator
Supply&InstallationoflightfixtureswithSigmaBallastincludinglamps,junction boxes,downrod/supports,hardwares rawlplugs,wires/cablesetc asrequired andconnectingittoswitchboards
SupplyandInstallationofPortableEmergencyLightonBatterysuitableforupto10 hours Installite/Canaramake Mountingarrangementforlamptobeincluded
1x18WBracketlight
WST71150withGI waterpipearm1mlongweldedtothecap
WFZ42250
WIF22228SGW
Liasoningchargeswithrespectiveauthoritiesforshiftingofpointofelectrical serviceandothers
Excavationinoutsidesoilincludingrefilling
Supplyinganderectingsteeltubulerpole1651x1397x1143mmthickwith 45x45x365mmthickand(56x27x27mm)respectively11mtrs LongasperIS 2713withtestcertificatefrommanufacturercompleteerecteddulypaintedwithtwo paintsofredoxideandtwocoatsofaluminiumpaintcompleteerectedinposition withMS baseplateof30x30x06cmsthickweldedatthebottomandsuitable polecaperactedwithsetscrewsorwieldedcompleteerectedCC foundationand plinthJunction/Loopingboxincluded
Note:Foritemnos 16,17and18,ratesshouldbeinclusiveofa
Supplyinganderectingcentrifugalwaterpump(Monoblock)withCI impler, primingfunelcockandcommonflangemountedonacommonshaftofinduction motorof400V3phaseAC supplyofminimum3H PMotorcapableof dischargingwater600to170litesperminutesat125to275meterstotalhead fromallclauseswithfoundationandwith50mmsuctionand50mmdelivery,water pumpshallbeconfirmingtoIS1520complete(Crompton/Kirloskar/Grundfosor anyotherequivalentmake)
Waterlevelcontrollerwithnecessaryprobesforcontrollingmotorforcutoffwhen uppertankwaterlevelisfull,whenwaterlevelinthetankcomestopredetermined levelpumpshallstartautomatically When waterlevelinthesuctiontankisbelow thewaterlevel,thepumpshouldnotstart Alsopumpshouldnotrundry The controllershallhavemanual autoswitchesandselectionofpump Therateshall includenecessarywiringwithcopperwires
DOLStartersuitablefor3HPmotorincludingoverload
Providingandfixing25mmPVCconduits/Casingcapingincludingallfittings
SECTION-VI: PLUMBING
15
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units ei eii eiii eiv 8(i) (ii) (iii) (iv) (v) 9a b c d e 10a b 11 12 LIGHTFIXTURESINCLUDINGCONNECTIONANDBULB a b c d e 13 14 15
comprehensivemaintenancefor60monthsbythevendor 16 17 18 19 A SANITARYSYSTEM
MEASUREMENT SHEET
Note: Allcataloguenos referredinvariousitemsofsanitaryfittingsareasperBelmonte /Hindustan/ParrywareSanitarywareCataloguesandallfixturesareJaguar Continentalseries
Providingandfixingapproved'Indian make white/colouredglazedvitreous chinawarefloormountedEuropeanwaterclosetcisternincluding- Nos
a)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock CPbrass flushbendetc
b)CIchairsupportsforthewatercloset
c)Whiteorcoloured solidplasticseat&cover veryheavyqualitywith rubber buffersfixedtotheclosetwithCPbrasspillarhinges
100mmdiaconnectorpipefromPtraptothejunctionofthesoilstackonexternal faceofbuilding Nos
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazed'vitreous chinawarewash'handbasincountertoporsuitableformountingbelow'counter comprising: Nos
a)White/colouredglazedvitreouschinawareovalshapedwashbasin,size 570mmx425mmwithsupportingMSorCIbrackets
b)1No15mmCPbrasspillarcockwithallfittings
c)1No32mmCPcastbrassbottletrapwithextensionpiecetowall,wallflange withrubberadopterwasteconnection
d)1NoheavyqualityCPbrassangularstopcock15mmsizewithCPbrassflexible connectorpipe Thesupportingbracketshallbeprovidedwith3coatsofapproved paintofapprovedshade
Providingandfixingvitreouswhite/colourchinawareurinalcomprising Nos
a)Largeflatbackwallhungurinalsize250x330x460mm
b)flushingtankof10ltrssupplyingto3urinalswithallfittings
c)CPbrasschromiumplatedflushpipingfromflushvalvetourinalterminatedwith a15mmscrewedspreader
d)32mmdomeCPcastbrasswaste
e)32mmnbCPcastrunningtrapwithextensionpipetowall,wallflange,rubber adopterforwasteconnection
Providingandfixing15mmsizeCPbrassbibtapISImarkedheavyqualityonGI lineswithflangeandCPconnectorofapprovedmake Nos
Recessedtypewhite/colouredtoiletpaperrollholdersize150mmx130mmin vitreouschinawarewithwoodenrodandspringincludingcuttingrecessinwall settingtherollholderincementsandmortar1:3reinstatementofwallsurfaceto originalconditionsetc complete Nos
ProvidingandfixingapprovedheavyISImarkedmakeCPbrass spoutsforbath with20mmthreadsoutsideand15mmthreadinsidecompletewithtaperedwall flange Nos Size15mm
ProvidingandfixingapprovedISImarkedmakeheavyqualityeasycleanvariety screwdownCPbrassstopcocksonGIlines,withfemalethreadedends Nos Size15mm
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareOrissawaterclosetcomprising: Nos
a)Orissapansize580mmx440mmwithboxriminletwithPtrapasrequired
b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareindowesternwaterclosetcomprising: Nos
a)Indowesternfloormountedsize600mmx460mmwithboxriminletwithPtrap asrequired
b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
100diaCI connectorpipefromPorStraptothejunctionofsoilstackonexternal faceofbuilding Nos
Providingandfixinggraniteurinalpartitionssize750x1200fixedtowallwithCP brassbolts,nuts&expandableanchorfasteners Nos
ProvidingandfixingISImarkedmakeSSsinkwithintegraldrainboard,single pressingofsize500mmx450mmwithsupportingbracketsCPbrasswaste bottle trapetc complete Nos
SupplyandfixingHindustanPilkingtonmakemirrors 6mmthickwithplainor bevelededge,8mmthickplywoodbacking,4NosCPbrassscrewswithCPbrass capsscrewedtorawlplugsembeddedinwall Nos
16
Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr No
11 12 1.3 14 15 16 111 112* 113 114 115* 117 118* 400 400 1100 700 1900 1700 400 400 400 1100 1500 800 100 400 400 400 1100 700 1900 1700 400 4 400 11 1500 800 100 400
MEASUREMENT SHEET
Supplyandfixing40mmCPbrasswastecouplingwithrubberplugandCPchain Nos
Providing&fixinginpositionheavytestedscrewdown15mmCPbrasssinkcock withraisedJshapedswingingspoutwithflangeofapprovedmake Nos
ThisitemisworkedoutbytheServicesConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
Providing,laying,fixingjointingwithscrewedjointsusingteflontapeGIpipes heavyqualityconformingtoIS1239includingallfittingssuchassockets,unions reducers,longorshortbends,elbows,nipples,flanges,checknuts,clampsetc testingthepipesandspecialsandpaintingthepipesandfittingswithonecoatof approvedprimer&finishingcoatsallasperspecificationsForpipesinexposed conditions:
Providing,laying,fixingjointingwithscrewedjoints'C'classheavyGIpipes conformingtoIS1239includingallfittings testing paintingwithbitumasticpaint protectionwrappingwithHessienfacedpolyethylenetaping&paintingcompleteas perspecifications Forpipelineslaidbelowgroundlevelandlaidinchasesin walls Therateincludesexcavationandcuttingchasesinwallsandreinstatement)
Providing,fixingandtestingheavyqualitygunmetalorbrassballvalvewith screwedends20kgmclassonGIorcopperpipelines(Leader/ZOLOTOmake)
ProvidingandfixinginpositiontestedheavyqualityISImarkedfullwaygunmetal gatevalveofneworequivalentmakehavingbothendsscrewedfemale conformingtoIS778:1984etc complete
i)50mmdia
ii)40mmdia
iii)32mmdia
iv)25mmdia
v)20mmdia
vi)15mmdia
Providing erecting fixingandcommissioningPVCoverheadwatertank(BMC approved)includingmakingofproperplatformasperconsultant'sdirection,lifting oftanktoterracefloorlevel,placingoftankonplatforminproperalignment, makingofinlet/outletconnectionsasperbye-lawsetc complete
i)5000litrescapacity
ii)2000litrescapacity
iii)1000litrescapacity
Providing,fixinggunmetalnonreturnvalveofapprovedquality 80mm 65mm 50mm 40mm 32mm
ProvidingandfixingapprovedISImarkedmakeCIflangedwatermetersdirect readingtypecalibratedinlitres&kilolitrestestedandapprovedbyMCGMwithdirt box(strainer)includingmakingnecessaryflangedjoints,testingetc complete 40mmsize
50mmsize
Constructingbrickmasonryvalve&meterchambersin230mmthickbrickmasonry incementmortar15usingfirstclassbricksconstructedoverabedof150mmthick cementconcrete1:2:4plasteringinsideoutsideandallexposedsurfacewith 20mmthickcementmortar13 finishing'insidewithafloatingcoatofneatcement providing&fixingCIframe&coversize, weightmentionedbelowpaintingallCI itemswith3coatsofapprovedbitumasticpaintetc complete
17
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units 120* 130* B WATERSUPPLYSYSTEM 21* 22* 23* 24* 25* 26* 27* 28*
15mmnb 20mmnb 25mmnb 32mmnb 40mmnb 50mmnb 65mmnb 80mmnb 100mmnb
15mm
25mm 32mm
20mm
80mm 65mm 50mm 40mm 32mm 25mm 20mm 15mm
100 100 100 100
MEASUREMENT SHEET
Chamber600x600mmclearinsidewith600x600CIframe&coverweightingnot lessthan72kgms Depthofchambernotexceeding1000mm
ProvidingStructuralsupportforpipelinesusingchannels,tees,angles,flats& platesfabricationbycuttingthreading&weldingifrequired,applyingonecoatof redoxideprimerandthreecoatsofsyntheticenamelpaint,includingnecessary boltsnuts,washeretc asrequiredbytheEngineer-in-charge Theweightofthe supportshallbecalculatedonthebasisofcatalogueweightsofsectionsused (weightofbolts,nutsetc willnotbeconsidered)
Providing&fixingbrassfloatvalveswithbrassrodandcopperfloat suitableto withstandapressure2 kg/sqcm
50mmnb
40mmnb
Excavationintrenchesforpipelinesofrequiredwidthanddepthasdirectedby Engineer-in-chargeincludingtrimmingbottomandsides,excavationforsockets includingrefillingwithselectedexcavatedmaterial(afterlayingofpipeline)in 200mmlayers,wateringconsolidationdisposalofsurplusearthwithin50metc complete
Inordinarysoil(forCIpipelineslaidoutsidethebuildingonly)depthnotexceeding 15m
-Do-insoftrock
ProvidingandfixingbestIndianmakeCPbrassairvalveswithisolationvalvefixed onGIlines
15mmnbairvalvewith15mmisolationvalve
20mmnbairvalvewith20mmisolationvalve
Providingconnectionstoequipments(Kitchen/Laundryetc includingprovisionof controlvalve runningjointwithunionetc complete
65mmconnections
50mmconnections
40mmconnections
32mmconnections
25mmconnections
20mmconnections
15mmconnections
SupplyingandinstallingBourdentypepressuregaugesrange0to20Kg/sqcm calibratedbothinpsiandkg/sqcm with10mmbrassgaugecocketc complete
Providingandfixingpipesleevesupto600mmlong,cutfromheavyqualityMS pipesconformingtoIS1239or3589(dependingonsizeofpipewithMSflange conformingtotable13ofIS 6392onbothendsanda6mmpuddleflangeatthe centreofthesleeve,allflangesweldedtopipe,fixingthesleeveinpositionbytack weldingtoreinforcementetc complete
40mmnb
50mmnb
65mmnb
80mmnb
100mmnb
Forthepurposeofthiscourseanapproximateamountisbudgeted
Providingandfixingcastiron traps of selfcleansing design with watersealnot lessthan50mmwith or without vent,including setting the trapin1:2:4cement concreteetc complete Thetrapshall be P' or S'type as required Trapwith 100mm inlet and100mmdiaoutlet
Asinitem31buttrapwith75mmoutlet
Asinitem31buttrapinPVC
Asinitem32butwithPVCtrap
Providingandfixingstainless steel gratingof 18 gaugethick,withcircular perforationofapprovedpatternoverCItraps Thegratingshallbeofsize100mmx 100mmorcircularof100mmdia(asdirected) and shallbesetin cement,sand mortar1:3etc complete
-Do-gratingofsize150mmx150mm
Providing, fixing, jointingand testingPVCWCpanconnectorofapprovedcolour with or withoutvent horn all as perrequirementsofEngineer-in-charge Size 100mmi/d-Length300mmto400mm
Supplying,laying,fixingjointing&testingheavyISImarkedcastiron spun soil pipes/centricastpipesincludingallfittingswithorwithoutinspectiondoors vents cowls at topetc jointing with leadcaulked joints all as perspecification and as directedbyEngineer-in-charge 150mmi/d 100mmi/d
18
Description Quantity PLineArea/Perimeter Height/Width No Total Units
Sr No
29* 210* 211* 212* 213* 214* 215* C INTERNALDRAINAGESYSTEM 31* 32* 33* 34* 35* 36 37* 38* ThisitemisworkedoutbytheServicesConsultant
MEASUREMENT SHEET
Providing, laying, jointing with screwed jointsusing teflon tape GI pipesof classTataorZenithconformingtoclassheavyofIS1239withallfittingstestingthe piping, painting with 2coatsofbitumasticpaintwrapping with Hasseinfaced polyethylenetapeintwo layers and againpaintingwith2coatsofbitumastic paint Therateincludesforcuttingchasesinwall&floorsforembeddingthepipe andreinstatementofsurfacetooriginalconditions 50mmi/d 40mmi/d 32mmi/d
Providing and fixing inposition cast iron rain water inlets withgravelguard anddometypegratingspeciallycastgenerallyconformingtodrgs
Inletfor:
150mmi/dpipes
100mmi/dpipes
Providing and fixingleadsheet flashing madeoutof3mmthickleadsheets settinginalayerofcoldbitumenetc complete Thesheetshallprojectatleast 150mmallaroundthepipeand shallbetuckedintothepipeatleastby100mm
150mmi/dpipes
100mmi/dpipes
ProvidingandfixingMSsupportsforpipesfabricatedfromMSflatsanglesand platesincludingfixingthebracketstowalls,slab,beametc withanchor,fasteners 12mm'U'or'J'boltsforfixingthepipestoclamppaintingwithonecoatofprimer andtwocoatsofapprovedpaintetc complete
Providingandlayingcementconcrete1:2:4forbedding,envelopeshaunchesetc forthepipesincludingmixingplacingformworkcuringetc complete
SupplyinglayingfixingjointingandtestingPVCdrainagesystem(SWR)including fittingswithorwithoutinspectiondoors,vents,cowlsetc allasdirectedby engineerincharge
110OD
75OD
ProvidingandfixingPVCplainor multi floor traps of selfcleansingdesignwith watersealnotlessthan50mmwithorwithoutventincludingsettingthetrapsin cementmortaretc complete Trapswith125mminletand75mmoutlets
Providingcleanoutsincastiron drainpipingcomprisingGIheavyclasssocket andscrewed plug,connectingCI pipewithleadcaulked jointetc complete
150mm 100mm
75mm
Supply,laying,jointingandtestingPVCpipesincludingallmouldedfittings conformingtoIS4985(10Kg/sqcmvariety)etc complete
50mm OD
40mm OD
32mm OD
ProvidingandfixinginpositionheavyISImarkedlongarmCI nahanitrapofIS 1729weighing9kgofNecoorEquivalentmakeofsize100x75x500mmdiaoutlet includingembeddingonflooringatrequiredlevelwithM150cementconcreteall aroundandbelowthetrap,supplyingandfixingbrassCPsquaregratingofsizeof 150x150mmwithbrassCPcoverplateasspecifiedetc complete
Providing fixingandjointinginproperalignment&positionheavyISImarked 50mmdia CI pipeofNecoorEquivalentforventconformingtoIS1729withall necessaryfittings,likeoffset,bend,cowletc includingerectionofscaffoldingat requiredlevel,makingholesinwallsasrequired,fixingofpipe&fittinginposition, leadjointing/fillingofjointswithCM1:3(onlyonapprovalofconsultant) reinstatementofsurfacesetc complete
Providing,fixingandjointinginproperalignment&positionheavyISImarkedCI CentripipesofKapilanshorEquivalentmake(withinbuildingline)fordrainage conformingtoIS3929of150mmdiameter sizewithallnecessaryfittings,like offset,bend,etc includingexcavationuptorequiredlevel,makingholesinwallsif required,layingofpipeatpropergradient,leadjointing/fillingofjointswithCM1:3 (onlyonapprovalofconsultant),reinstatementofsurfacesetc complete
Providingandconstructing300x300mminternalsizebrickmasonrygullytrap chamberincludinglayingof100mmthickPCC1:3:6inbed 115mmthickbrick wallsinCM1:5,fixingofglazedstonewaregullytrapofsize150x100mm, makingconnectionofwastewaterpipetoit,plasteringinsidethechamberwithCM 1:3toformhopper,fixingofheavyCI coverwithframeweighingnotlessthan7 kg inPCC1:2:4&makingflooringlevelontopetc complete
19
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units 75mmi/d 65mmi/d 50mmi/d
39 310* 311* 312* 313* 314* 315* 316* 317 318 319 320 3.21
MEASUREMENT SHEET
Providing,layingandjointingISImarkedfirstquality A’gradesaltglazed stonewarepipe&bend,includingexcavationtothelevelofrequireddepth,laying of100mmthickPCC,placingofpipeonPCCasspecifiedatproperalignmentand gradient sealingthejointswithtarredgasketofhemporropeyarn caulkingwith cementmortar1:2,testingofpipeline,encasingofpipeasspecified,curing, refillingetc complete
i)100mmdia
ii)150mmdiafordepthbetween045and060Mtrs
iii)150mmdiafordepthbetween060and100Mtrs
Providing&fixing150mmdiameterISImarkedfirstquality Agradesaltglazed stonewaresewertrapasspecified
i)150mmdiameter
Constructingbrickmasonryinspectionchamberofsizeof900x450mmanddepth asmentionedinitw\esmbelowincludingexcavationupto requireddepth,layingof 100mmthickPCCfoundationbedin1:3:6mix 230mmthickbrickworkinCM1:3 20mmthickplasteringofwallsinside&outsideasspecified,makingofsmooth channel&haunchinCM1:2,150mmthickPCCcopingontop,fixingofCI manholecoverofNecomakeweighingnotlessthan75kg,backfilling,removalof surplusearthasspecifiedetc complete
i)Depthbetween045and060m
ii)Depthbetween060and100m
TOTALOFSECTION-VI
Providingandlayingmultiplelayersovertheinternalcourtyardforwaterproofing
20
Sr No Description Quantity PLineArea/Perimeter Height/Width No Total Units 322 323 324* A* Developmentwork B* Providingplantsandtreesaplings: b1* b2* b3*
a)BituminousWaterproofMembrane 100 637 SQ MT b)Sand 150000 100 3822 Kg d)GeotextileLayer 100 637 SQ MT e)RedSoil 100000 100 1274 Kg Hibiscusrosa Nos Rosarubiginosa Nos Aloebarbadensismiller Nos c)PolyethyleneDrainageMesh 100 637 SQ MT
SECTION-VII: LANDSCAPINGANDGARDENING 637 025 637 127 4000 5000 3000 637 500 200 800 400 900 270