COMMUNITYTOILET ATTROMBAY,MUMBAI
VATSALVISHARIA
ROLLNO|A20-43
THIRDYEARB.ARCH
2022-2023
SCHOOLOFENVIRONMENT
ANDARCHITECTURE
WD-SEA-S022
1.SUMMARYSHEET
2.BILLOFQUANTITIESANDRATES
3.MEASUREMENTSHEET
4.DIAGRAMSFORBOQ
VATSALVISHARIA
ROLLNO|A20-43
THIRDYEARB.ARCH
2022-2023
SCHOOLOFENVIRONMENT
ANDARCHITECTURE
WD-SEA-S022
1.SUMMARYSHEET
2.BILLOFQUANTITIESANDRATES
3.MEASUREMENTSHEET
4.DIAGRAMSFORBOQ
NB:ALLWORKSSHALLBECARRIEDOUTASPER ARCHITECT'SSPECIFICATIONS ALLWORKSSHALLBECARRIEDOUTASPERAPPROVEDDRAWINGSONLY
ForallItemsinallSections:Rateshallincludetransportation,loading/unloading,providing/supplying/laying/fixing/installing/ fabricating/testing/commissioningetc onsite RateshallalsoincludealltaxessuchasVAT excise salestax octroi etc
SECTION-I: SitePreparation&Cleaning
Cleaningandclearingthesiteofallrocks boulders brick-bats stone bushes shrubs,etccomplete,asdirectedbythearchitectforstartofconstructionactivity
TOTALOFSECTION-I
SECTION-II: CIVILWORK
Note:
1)TheitemsgivenbelowshallbeasperSectionA""Earthwork,MetalPacking& SubsurfaceDrainage"ofthespecifications
2)Rateforexcavationshallincludedewateringduringtheexcavationincluding shoring,struttingetcandkeepingitdryduringexcavationandconstruction
3)AllearthworkshallbecarriedoutasperArchitect'sinstructionsandsafety normsasperrelevantIScode Therateshallincludeallscaffoldingandmeasures forcordoningoffareasduringdismantling,providingsignboardsetc
4)Alldebrisandscrapmaterialsfromearthworkshallbecontractorspropertyother thanthatwhichisreusedforback-fillingetc andthisdebrisandscrapmaterials shallberemovedawayfromsiteimmediatelyonhisown Thecontractortogive rebateinratesagainstmaterialsandscrap/debrisfromsuchdismantledwork whichshallbecontractor'sproperty
5)Forallearthworkitems,thecontractorshouldcarefullystackallexcavated materialatsiteaspertheinstructionsoftheArchitect Alldebrisassociatedwith theearthworkshouldhoweverbedisposedoffbytheContractor
6)Themeasurementofexcavationshallbetakenincum asperrectangular trenchofbottomwidthofconcretemultipliedbyverticaldepthoffoundationfrom groundeventhoughcontractormighthaveexcavatedwithslopingside/fulllength trenchforhisconviency
Surfaceexcavationandexcavationforretainingwalls,basement,watertanks, effluenttreatmenttanks,etc includingbackfillingofapprovedexcavatedmaterials infoundations &behindretainingwallsaftercompletionofwaterproofingetc wateringandconsolidating,cartingawaysurplusearth, includingpreparingthe surface (Note:Allbackfilling&spreadingofearthshallbecarriedoutinlayersnot exceeding200mmandcompactedto90%ordinaryproctordrydensity)
Fillinginplinthandinotherplaceswithapprovedmurumbroughtfromoutside, includingwateringconsolidatinginlayersnotexceeding200mmby8-10tonnes roadrollerorotherapprovedmechanicalequipmentetc
Anti-termitePreconstructionTreatment:(AsperIS:6313Part-III)(Note: Anti-termitetreatmentshallbecarriedoutthroughspecialisedagencyreputedin PestControltreatmentandapprovedbytheArchitect Thecontractortogive10 yearsguaranteeonasuitablebond)
Providingpost-constructionalanti-termitetreatmentbydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion,wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC,ISIapprovedconforming(IS8944),Includingtreatmentofwoodfor termites,borers,wetrotsanddryrots Coveredfloorareashallbemeasuredfor payment (GroundFloor)
Providing,chasing,inserting/layingDampproofcourse50mmthickM-20cement concretelayerandbitumenusingcementwithapprovedwaterproofingcompound attherateof1Kgper50kgofcementetc complete
Note:
1)TheitemsgivenbelowshallbeasperSectionB"Concrete-Plain&Reinforced" ofthespecifications
2)ForsmallconcreteonapprovalofConservationArchitect,weighbatched concreteasperdesignmix,inmanuallyormechanicaltypeoperatedweigh batcherdialtypeormechanicaltypeofminimumcapacity650Kgsshallbeused Weighbatchershallbecalibratedregularly
3)Forallmajorconcretepours,Contractorshallusereadymixedconcrete(RMC) ofUnitechPrefabLtd orM/s Larsen&ToubroLtd approvedAgencies Only53 gradecementshallbeusedinRMC Aggregatepropertiesandgradingdesign mix,quantityofsuperplasticiser,settingtime,amountofslumpatthepouringsite shallbegotapprovedbeforeitsuseineachmajorconcreting
4)Concretemixproportionwillbebasedon50kg weightofcementbags deliveredatthemixer
5)TheContractorisentirelyresponsibleforthedesignofconcretemixes The designishowever,tobeapprovedbytheArchitect
6)ConcreteM-20/20meansconcretemixM-20gradeusingmaximumsizeof coarseaggregates20mm
7)Shuttering formwork centeringshallnotbepaidseparatelyandshallconform toSection-C
8)Curingcompoundmaybepermittedonlyforinaccessiblelocations
9)OnlyRiverSandshouldbeused Washingofsandinrotaryscrewtypewashing machinesisamust
10)RatesshallbeinclusiveofcostofSuperplasticiserofapprovedqualityandof approveddosage
11)Ratesshallbeinclusiveofprovidingpockets,holes,inserts,pipes,etc
12)Mechanicalvibrators,internaland/orexternaltobeused
13)AlldefectiveconcreteifapprovedbyArchitect,shallberepairedbythe contractorathisowncost usingapprovedepoxymortarorPolymermodified mortarasperManufacturer'sspecifications
14)Therateshallincludethecostofapplying2coatsofpolymerbondingagenton allsurfaceofoldornewconcreteatconstructionjointpriortoconcretingagainst thesame
15)Useoffinesandwithpropergradingisamust
16)Screeningofmetal-IandIIforremovingexcessiveflakyunderandoversize material,stonedustetc isamust
17)Onlyapprovedmouldreleasingagentshouldbeused
18)Cleaningofshutteringplatesbymechanicalbuffingaftereveryuseisamust
19)Allconcretesurfacesshallbeformfinished
20)Whereplasteringisspecified concretesurfacesarerequiredtobehacked immediatelyaftertheremovalofformworkasdirectedbytheArchitectwherever required Additionalrateshallnotbepaidtocontractorforhacking
21)Contractorshouldmakearrangementfortablevibratorforcastingthecover blocksofrequiredsizeandgrade
22)Rateshallbeinclusiveofprovidingcoverblocks Coverblocksshallbemade ofthesamegradeofconcreteofstructuralmemberinwhichtheblocksaretobe used
23)Alljointsinshutteringshallbesealedbyuseof5mmthickcompressible materialgasketsandfixingagent
24)Constructionjointshallbeminimuminnumbersandtheirlocationshallbe approvedbytheConsultant Constructionjointsshallbetreatedproperlywith bondingcoatofapprovedmaterialtobeappliedattheoldconcretebefore commencingthefreshconcretingoperations
25)Informfinishsurfacesthepatternstobeprovidedfortheformworkshallbeas perarchitectssuggestions
26)Allsack-rubbedsurfaceshallbesackrubbedwithwhitecementofsuggested proportionasperArchitectsapproval
27)Allconcealeditemslikeconduits,junctionboxes,fixturesetc shallbelocated asperdetailsandlocationstobeapprovedbeforecasting
NotesforFormwork:
Note:1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications
2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping
3)Amockupofformworkforcolumns typicalcolumn-beamjunction beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework
4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed
5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained,remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorathiscost
6)Ratesquotedshallbeinclusiveofallformworkatalllevels
7)Rateshallincludeuseof5mmthickcompressiblegasketmaterials,fixingagent, adhesivetapeandmechanicalbuffingofshutteringplates
8)Onlyapprovedmouldreleaseagentshouldbeused
9)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust
10)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork
11)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect
12)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately
13)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect
14)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection
15)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant
ProvidingandlayingConcreteM20/40usingRMCforallPCC etc includingsideformsifrequired The rateshallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads& lifts,allfloorsallchargesrequiredincludingtransportation,centering,formwork, compacting,rougheningthesurfaceifspecialfinishistobeprovidedandcuring etccomplete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkoffloorslabon gradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes towardsplant&machinery labour allleads&lifts allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc complete (level1at-165m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level2at+015m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level3at+15m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level4at+315m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level5 at+375m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level6at+45m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level7at+63m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation shuttering centering formworkasperconditionbelow etc complete (level8at+675m)
CUM
CUM
CUM
CUM
CUM
CUM
CUM
CUM
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation shuttering centering formworkasperconditionbelow etc complete (level9at+905m) CUM
ProvidingandlayingconcreteM25/20usingRMCfor ongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork asperconditionbelow,etc complete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork asperconditionbelow,etc complete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork asperconditionbelow etc complete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc complete CUM
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork asperconditionbelow,etc complete
Providing&layingM30/20,usingRMCforRCCincludingpumpingforfoundation, pilecaps,raftslab,column,walls,shearwalls,boxcolumn,retainingwalls,plinth beams,floorbeams,invertedbeams,slabs,staircase,droppardis,chajja, parapets,pergolas,trenchslabandbeamsinstructuralfloors,loftslabsatall levels,lintelbeams/verticalstiffenersetcincludingRCCundergroundwatertanks, septictanks,effluenttreatmenttanks,overheadwatertanksetccomplete Therate shallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads&lifts, allfloorsallchargesrequiredincludingtransportation,shuttering,centering, formworkasperconditionsbelowetc complete
a)RaftSlab
b)RaftColumns
c)RaftExternalRetainingWalls
d)RccColumns
Providing&layingConcreteM20/40,usingRMC,inalternatebaysfor75MM andpavingincludingcompacting,vibrating,curing,finishingto correctline&levelwiththeuseofwoodenbottomandsurfacefinallyfinishedwith broomsasdirectedbyArchitect Jointsofandasprovidedinalternatebaysshall befilledwithbitumenetc allcompletetothesatisfactiontotheArchitect SqMt
ProvidingandconstructingRCCundergroundwatertankincludingexcavationinall typesofsoil,refillinginsidesoftank,trimming,dressing,leveling,stackingand disposalofsurplussoilandincluding:
i)Rubblesoling230thk
ii)PCC,M20/30belowraft
iii)M-25/20RCCworkinraftslabs,sumpbase,beams,RCCwalls,columns,top slabsetc includingunwrotshutteringtoRCwallsatalllevels
iv)TMTreinforcement
v)Waterproofcementplastertoinsideofwatertanks
vi)BoxtypewaterproofingtreatmentforraftandwallsofUGtank
vii)Patentedcementbasedwaterproofingtreatmenttotopofslabs
viii)50mm thk IPStoraftslab
ix)Providingandfixingcastironmanholecovers2nos 600mmdia withlocking arrangements
x)PVCwaterstop150mmdia;embeddedintakeandoutletpipesetc UGtankcapacity
Providing,erecting,fixingandcommissioningSintexorapprovedequivalent doublelayeredtanksonoverheadelevatedpedestalasdirectedincluding scaffoldingallalliedplumbing,valves,stopcocks,MCGMcertifiedwatertankcap, includingcleaningetc completeasperthesatisfactionoftheArchitect
Litres
1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications
2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping
3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework
4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed
5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained,remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorat hiscost
6)Rateshallincludeuseof5mmthickcompressiblegasketmaterials,fixingagent, adhesivetapeandmechanicalbuffingofshutteringplates
7)Onlyapprovedmouldreleaseagentshouldbeused
8)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust
9)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork
10)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect
11)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately
12)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect/consultants
13)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection
14)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant
Notes:
1)TheitemsgivenbelowshallbeasperSectionD:'Reinforcement'ofthe specifications
2)CoverblocksshallbeofgoodqualityconcreteM30/10andshallbevibratedon atablevibratortoreducethepermeability
3)Whereverweldingofreinforcementisspecified,thesameshallbecarriedout conformingtoIS:9417orIS:2751 Weldingshallbecarriedoutbyapproved qualifiedweldersonly Onepercenttestingofweldsshallbecarriedforalltypesof welds
4)Overweightofthesteelshallnotbeconsideredforcalculatingconsumptionand paymentpurpose,IS constantforweightofdifferentdia ofbarsshallbe consideredforpaymentaswellasconsumptionpurpose
5)Columnreinforcementbarsarerequiredtobelappedinthemiddleportionof columnsasperIS13920 Properarrangementshallbemadetosupport reinforcementprojectingabovefloorlevel Similarlylapswithinadistanceof2D (depthofbeam)or1/4spanfromthefaceofthecolumnarenotallowed The overhangingbarsshouldbeproperlysupported Thecostoftheseworksis deemedtohavebeenincludedintherate
ProvidingandfixinginpositionmildsteelreinforcementofTATA/Vizag/SailSteel ofvariousdiametersforRCC piles,pilecaps,footings,foundations,slabs,beams, columns,canopies,staircases,dowels,chajjas,lintels,pardis,copings,fins,arches etc asperthedetaileddesigns,drawingsandschedulesincludingcutting, welding,bending,hookingthebars,bindingwithGIwiresandconcretecover blocksetc complete Noseparatepaymentforchairs laps wastageandbinding wirewillbemade
Sameasitemd1abovebutforProvidingandfixinginpositionhighyieldstrengths deformedbarreinforcementofTATA/Vizag/SailSteelwithyieldstressnotless thanFe415ofvariousdiametersforRCC piles,pilecaps,footings,foundations, slabs,beams,columns,canopies,staircases,dowels,chajjas,lintels,pardis, copings,fins,archesetc asperdetaileddesignanddrawingscheduleincluding cutting,bending,hookingthebarsbindingwith18SWGGIwiresincludingwelding andsupportingasrequiredandprovidingconcretecoverblocksatalllevels includingallleadsandliftsetc complete Noseparatepaymentforchairs,laps, wastageandbindingwirewillbemade
Sameasitemd2above,butforTMTSteelReinforcementofTATA/Vizag/Sail Steel
StainlessSteel304screws,nails,bolts,fasteners,etc forallrepairworks
SQM
ThisitemisworkedoutbytheStructuralConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
Supplying,fabricating,erecting,aligninginposition,fixing,StructuralSteel ofTATA /Vizag/SailSteelinalltypesofmembers(Box,Ropes,I-sections,C-sections, L-anglesetc)forColumns,Beams,TrussRafter,Purlinforroofs,lofts,stairs, mezzanines,storageracksforparaffinboxes,portals,braces,underpinning, shoring,frames etc Theratetoincludecutting,anchorfasteners,bolting, welding,wastageandapplicationofepoxybasedpaints(Asianmake)asper manufacturer'sspecificationsandasdirected Therateshouldincludepaintingof thesteelasstatediniteme5below
COLUMNS-ISMB250
CIRCULARSTEELHOLLOWCOLUMN-NB200M
Providingfabrications,erectingandfixingSS Railing
METRIC TON
i)SS PoleMadein16gauge50mm DiameterISapprovedSS304pipewitha ornamentalSSringatthebottomendsSS topatapexforassemblyofupper Handholdpipewholeunitprovidedwithmirrorfinish (Foraheightof12M) kg
Note:
Measurementshallbetakenforcompletelaidroofinsquaremeter Overlapswill notbepaidextra Therateshallincludeallthematerial,labourbolts,nut,washers andtoolsandplantsetc complete
SteelFramedRoofingSystem
ProvidingandfixingofSteelFramedRoofingSystem ExternalSheet:Klippon/ SteellockAZ150SMPcolourcoatedGalvalumein058mmTCTandincluding screwsandclips InternalSheet:Hi-Rib/HispanAZ150BareGalvalume/SMP colourcoatedGalvalumein047mmTCTincludingscrews Insulation:Supply andLayingof50mmthicklogfiberresinbondedfiberglassrollinsulation16kg/m3 densitytobefixedbetweeninternalandexternalsheets SubGirt:G I Purlins40 x50x40mmx16G(16mm)galvanisedsteelfixedtopurlins/girtwithselfdrilling fastenersatmax 500mmcentersandsteelbaseplatesofsizes150x150x6mm SQM
BOXSECTION25x50mm kg
BOXSECTION100x50mm kg
Providingandfixingofflashingofallsizesforf1above
ThisitemisworkedoutbytheConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
Providing,supplyingandinstallingcellular(doublewalled)polycarbonatesheet/ tetrapacksheet(dupontorequivalent)roofinginclusive offixingtostructuralsteel supportsystemasperdesignandmanufacturer'sspecification Thecostshallbe inclusiveofalltaxes Allnecessaryscaffolding,craneandaccessoryworktobe usedincarryingouttheworksistobeincludedinthecost Thecontractorshall havetotakeduecareofthesurroundingbuildingandseetoitthatthefacadeskin anditselementsarenotdamagedintheprocessofcarryingoutthiswork
TOTALOFSUBSECTION-F
Note:
1)Theitemsgivenbelowshallbeasper'MasonryWork'ofthespecifications
2)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction
3)CementformanufacturingconcreteblockstobeprovidedbyContractor
4)Onlyselfsupportingscaffoldingwillbeallowed,noholesinmasonrywouldbe permitted
5)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc
6)Factoryincludingblockmakingmachineformanufacturingofconcreteblocks shallbeapprovedby Architect-in-charge
7)Thecementforblockmasonryshallconfirmtotherequirementofminimum cementrequirementforPCC ofconcretespecifications
8)Requiredquantityofconcreteblocksaretobemanufacturedwithgroovesto accommodatetheconduitpipes/waterpipesetc Thegroovesshouldbestaggered onbothsides
9)Therateforconcreteblockmasonrywallsshallbeinclusiveofproducinghalf blocksandoddsizedblockstosuittheconstruction
g5
10)Mortarsforallmasonryworkshallbemixedinanapprovedmortarmixeror concretemixer
11)Handmixingofmortarwillnotbeallowed
12)Onlyriversandand43gradecementshallbeused
13)Washingofsandinrotaryscrewtypewashingmachinesisamust
14)Bricksusedshallbeoffirstclassandshallbeofregularinshapeandtheir edgesshouldbesharpandshallbefreefromcrack Brickshallbefullysoakedin cleanwaterbysubmerginginatankforaperiodof12hoursimmediatelybefore use
15)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc
g7*
Providingandlaying in1:6C:M aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins,columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
230mmthickbrick(firstclass)masonrywall
SQMT
Providingandlaying in
150mmthickbrick(firstclass)internalmasonrywall
1:6C:M,aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins, columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
SQMT
Providingandlaying in 1:6C:M,aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins, columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum) SQMT
100mmthickbrick(firstclass)internalmasonrywall
ProvidingandfixingPCC/stonecopingoverterraceparapethavingdimensions 330mmwide100mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
RUNNING MT
Providingandfixing overterraceparapethavingdimensions 230mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3 CUM
a)1450mm
b)2300mm
c)950mm
d)1500mm
e)3725mm
RCCLintelsandSill
ProvidingandfixingRCCLintelsandSilloverterraceparapethavingdimensions 150mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1100mm
b)1450mm
c)1650mm
d)1250mm
e)950mm
f)1500mm
ProvidingandfixingRCCLintelsandSilloverterraceparapethavingdimensions 100mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1100mm
b)1450mm
ProvidingandfixingRCCLintelsoverterraceparapethavingdimensions230mm wide230mm thicknessinpiecesof600mmlengthoveramortarbeddingofCM 1:6/Limemortar1:3
a)3725mm
ProvidingandlayingBB cobainallpositionssuchasplinthsandramp
Notes:
1)Theitemsgivenbelowshallbeasper'Plasteringofthespecifications
2)Scaffoldingforplasteringshallbeofselfsupportingtype Holeswillnotbe allowed,tobemadeinthemasonryorRCCworkforanchoringthescaffolding
3)OnlyRiverSandshouldbeused Howeverwashingofsandinrotaryscrewtype washingmachinesisamust
4)Mortarforplasteringworkshallbemachinemixedinamortarmixerorconcrete mixer Handmixingofmortarwillnotbeallowed
5)Therateforplasteringshallalsoincludeprovidingandmixing/applyingan approvedbondingagentasperdirectionofArchitect-in-charge,andalsoapplying approvedhack-aidonsurfacereceivingplaster
6)Only43gradecementshallbeused
7)Rateshouldbeinclusiveofscaffoldingandcuringshallbestartedassoonas theplasterhashardenedsufficientlynottobedamagedwhenwatered Theplaster shallbekeptwetforatleast10days
Providing12mmthickInternalcementplasterintwocoatsincementmortar1:4 with/withoutneeru finished smoothforallRCC/brickblockmasonrywork includingcuring,andscaffoldingetccomplete
Providingandapplying18mmthickcementplasterincementmortar1:4 without/withneerufinishedsmooth forRCC/brick/blockmasonrycompleteinall respectsincludingscaffolding,bondingagent,curingandasdirectedbyArchitect
Providing&applyingacontinuouscementplasterdripmouldofsize50mmwide and15mmthickunderRCCpardi,chajjaandaroundwindowopeningsatalllevels includingnecessaryscaffolding,stagingetc andcuringcomplete
Notes:
1)Theitemsgivenbelowshallbeasper'Paintingofthespecifications
2)ScaffoldingforPaintingshallbeofselfsupportingtype Holeswillnotbe allowed tobemadeinthemasonryorRCCworkforanchoringthescaffolding
3)ThebrandsofthePaintshallbespecifiedandreadymadepaintofrequired shadeshouldbeused
4)Thesurfaceshallbemadeperfectlysmoothbyrubbingwithsandpaperof differentgrades
5)Allholesandopenjointsshouldbefilledwithstrongputtyorwithamixtureof glueandplasterofparisandsmoothenedbyrubbingwithsandpaper
6)Insteelwork,allscales,dirt,suppliersdeliverymark,oil,greaseetcshallbe removedwithsandpaperbeforepainting Specialcareshallbetakenforcleaning thecorners
7)Eachcoatsshallbeallowedtodryupperfectlybeforethesucceedingcoatis laidoverit
8)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction
Providingandapplying3coatsoveracoatofprimer,ofoilbounddistemperof approvedshadeandofapprovedmakeoverconcrete/plasteredsurfaces includingpreparingofthesurfaces,scaffoldingetc completeinallrespects
Providingandapplyingacrylicemulsionpaintofapprovedquality,finish,colourand shadetooldandnewsurfacesinthreecoatsincludingpreparingthesurfaces, applyingprimer putty etc complete
Notes:
1)Theitemsgivenbelowshallbeasper'Flooring'ofthespecifications
2)Atleast6samplesforallfinishingitemsofwork,fromdifferentapproved sourcesshallbesubmittedbeforestartingtheworkforapproval Architectin chargedecisionregardingtheshade,qualityandthesourceisfinal Alllike materialsofflooring,cladding,etctobefromsamebatchasperapprovedsample
3)Rateshallbeinclusiveofallexposedstone/tileedgestobechamfered,hand polishedandmouldedasdirected
4)Ratesforverticalcladdinginstoneofthicknessfrom6mmto25mmshallinclude exposedrightangularcornerjointsfinishedandedgespolishedandmouldedas perArchitect'sinstruction,withcutting6mmgroovesandalsoedgepreparationto suitcornerangles
5)Skirting/dado/cladding,becauseofvaryingheightwillbemeasuredandpaidon squaremetrebasisinsteadofonrunningmetrebasis
6)Therateforflooring/claddingshouldbeinclusiveofbedding/backcoatas specified Thethicknessofmortarbeddingorbackcoatspecifiedisminimum Thisthicknesswillvaryaccordingtothethicknessofflooringorcladdingmaterial soastosuitthespecifiedlevelorline TheContractorshallberesponsiblefor properbondingbetweenbackingcoat&masonryworkorRCCworkandhisrate shallbeinclusiveofprovidingandapplyingapprovedbondingagent
7)Forallverticalcladding,anapprovedchemicaladhesivefortilesasper manufacturer'sinstructionsshallbeusedandtheratesquotedshallbeinclusiveof thecostofthisadhesive,forathickness3mmto4mm
8)Unlessotherwisespecified,allsizestobeinmetricsystem
9)Scaffoldingforexternalcladdingshallbeofselfsupportingtype Holeswillnot beallowedtobemadeinthemasonryorRCCworkforanchoringthescaffolding
10)Therateforverticalcladdingshouldalsoincludetheworkonisolatedcolumns chamfers,etc
11)Noseparatepaymentwillbemadeforprovidingandfixing,oddsizedtilesof anyshapeandsizetosuitconsultantrequirement
12)White/ColouredcementwithmatchingpigmentsorJohnsonBALgroutwith appropriatecolourshallbeprovidedbyContractorathiscost
13)TheContractorshallprovidesuitablesupportsforsupportingthecladdingtiles andremoveitonlyafterthetileshavefirmlyadheredtoitslocation
14)Edgesofcladdingtilesfixedonthecornersofthecolumnsandwallsshouldbe polishedasperdirectiveofArchitect,orasindicatedinthedrawings
15)Themaximumthicknessofthepastepreparedbyusingtileadhesiveand appliedonthewallandcolumnsurfacesshouldnotbemorethan3mm Contractorshallhavenoextraclaimsonaccountofincreaseinthethicknessofthe pastebeyondmaximumthicknessasspecifiedaboveduetofaultyworkmanshipor anyotherreason
16)Mortarrequiredforbedding/backcoatshallbemixedmechanicallyinmortar mill Onlyriversandshallbeusedinthemortar
17)Allfixtures,electricalpoints,lightsetctobealightedwithtiling,groovesand pattern,flushwiththewallfaceasperdetailsanddrawings Amockupforthe sameshallbegotapprovedfromArchitect
18)Thecontractorsarerequiredtostudydrawingscarefullytounderstandfixing detailsofflooring,skirting,claddingetc,tokeeprequiredgroovesbetweendifferent finishesatdoorandwindowlocationsflooringandskirtingjunction,wallandceiling junctionetctomatchflushlinei e verticalplaneofwallandskirtingetc
19)Rateshallbeinclusiveofcostofscaffolding,grouting,curing,finalpolishingby non-slipwaxpolishandcleaningofsurfacesandalsodewatering&keeping surfacedryduringconstruction
20)Asample/mockupofflooring,cladding,etctobegotapprovedfrom,Architect
21)Alladditionalgroovestobeprovidedinvertical,horizontalanddirectionas shownindetaileddrawingsorasdirected
22)Tomakewallcladdingsurfaceandskirtingsurfaceflush,wallatskirtinglevel shallberequiredtorecessinsideasperfixingdetails Thenecessaryrecessesin RCCwalletcshallbetakenatthetimeofconstructionitself
23)Only43gradecementshallbeused
Providingandlaying15-32mmthickhandcutandmirrormachinepolishedgreen squareorrectangularrangingfrom200mmx200mmupto 600mmx600mmfinishedsizeandofapprovedcolourandshadeinsmaller patchesforrepairorinlargerareasincluding20mmthick1:2limemortarbedding or1:6cementmortarbedding,tobecompactedproperlybysuitablemethodas approvedbytheArchitect,beforelayingKotahstoneinposition Jointsfinished withneatcementslurry,widthofjointshallbebetween10mmto150mmlayingas perdesign,including3coatsofmachinepolishingafterlaying,curing,cleaning completeasdirected SQMT
Sameasitemk2abovebutforrisersandtreadswithmouldingfornosing,antiskid groovesetc complete SQMT
-Do-sameasinitemNo
ofheightbetween 100mmto2000mm,mirrorpolishedandmachinecut15mmthickkotahstone,and sizetomatchthejointsinflooring,etccomplete RUNNINGMT
Providingandlaying25-32mmthickhandcutandmirrormachinepolished squareorrectangularrangingfrom200mmx200mmupto 600mmx600mmfinishedsizeandofapprovedcolourandshadeinsmaller patchesforrepairorinlargerareasincluding20mmthick1:2limemortarbedding or1:6cementmortarbedding,tobecompactedproperlybysuitablemethodas approvedbytheArchitect,beforelayingKotahstoneinposition Jointsfinished withneatcementslurry,widthofjointshallbebetween10mmto150mmlayingas perdesign,including3coatsofmachinepolishingafterlaying,curing,cleaning completeasdirected
Sameasitemk6abovebutforrisersandtreadswithmouldingfornosing,antiskid groovesetc complete
ProvidingandfixingWhite/ceramicantiskidtiles{Kajaria,Johnson,somanyor approvedequivalent}200x200mmto400x400mminsizeandminimum6mm thickfordadooftoiletsinrequiredpositionlaidonabedof1:4cementmortar plasterof15mmthicknessincludingneatcementbacking,fillingjointswithwhite cementslurry,curingandcleaningcomplete (BasepriceoftileRs400/Sqm)
Providingandfixingwhiteceramictiles( ){Kajaria,Johnson,somanyor approvedequivalent}200x200mmto400x400mminsizeandminimum6mm thickfordadooftoiletsinrequiredpositionlaidonabedof1:4cementmortar plasterof15mmthicknessincludingneatcementbacking,fillingjointswithwhite cementslurry,curingandcleaningcomplete (BasepriceoftileRs500/sqm)
Providingandlayingfullbody8mmthick ofRestile/ Pedder/Johnson/Nitcooranyapprovedmakecolourorofsize150x150/200x 200/300x300/400x400/600x600/900x900mminclusiveofbeddingof CM 1:4,forlocalisedrepairsorinlargequantities,forflooring/skirting/dado, andwithcementfloatandJohnsonbalgrout
-Do-sameasinitemNok9abovebutforskirting/dadoofheightbetween100mm to2000mm,mirrorpolishedandmachinecut15mmceramicvitrifiestiles,andsize tomatchthejointsinflooring etccomplete
Providingandlayinginrequiredpositionchinamosaicflooringoverconventional waterproofingtreatmentoratgroundleveloverPCCorIPSbaseofapproved colourandpatternon40mmthickbeddingof1:4cementmortarincludingneat cementfloat,givingproperslopes,compaction,curingetc complete
Sameasabovebutforwashbasincounters
TOTALOFSUBSECTION-K
Notes:
1)CarpentryandJoinery,Timber,Steelcasement,AluminumDoorsWindows, skylightsopenable,slidingwindows,rollingshuttersandpolycarbonatesheet, curtainwalls,etc
2)Forallaluminumworks thecontractorshallsubmitshopdrawingforeachitem ofworkindicatingthesectionofaluminum,itsweightandjoinerydetailandtotal weightofwindow/door/partitionwallsetc Whereverpossiblerivetingshallbe resortedtoforconnection Alternativelyhotdippedgalvanizedpinheadedsheet metal/brass,screwscouldbeused Nomildsteelwithouthotdippedgalvanizing shallbeusedforanyfastenings,etc
3)TheratesshallnotbepaidseparatelyforAluminumsectionsusedonweight basis
4) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc
5)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
6)Alljointsbetweencivilworkandaluminumframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
7)Ratesforrepairsaswellasprovidingandfixingofnewdoors,windows,sky light rollingshutters etc inthissectionshallbeinclusiveofalltheitemsof hardware/fittingsandnoextrashallbepaidtothecontractortowardsthecostof hardware/fittings
8)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including,fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:
9)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)
10)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand all otherhardwareshallbeofDormaorapprovedequivalentbrand
11)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)
12)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized
13)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete
14)Doorhandles 'Dorma'TGDI35025Spullhandle 25mmdia 350mmlongor 'DORMA'TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect
15)BrassoxidizedBabylatches,75mmlongwith25mmx8mmthickboltcomplete withknob,Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal
16)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release
17)PlainMorticelocks6leversLatchBoltofGodrejmakeequivalentwithbrass bodyandchromeplatedflatplatetoedgeofdoorincludingfixingtotimberor aluminiumshutterframesetccomplete
RUNNINGMT
SQMT
RUNNINGMT
18)Sameasaboveitem(16)butwithdeadlock
19) 3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)
20) Doorbufferwithrubber/PVCbushshutterorwallmounted
21)Providingandfixing andrepairrateswillalsobeinclusivealdrops,handles stopperetc allcomplete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete SQM
Timberdoubleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete SQM
Glassdoubleleafpivotdoor
Providingfabricatingandfixinginpositionaluminiumframecomprisingofopenable opaqueglassshutter(lockinghandlesandpullhandlesforshutter,withfloor springforrotation)includingmaskingofjamsbeforecompletionofworkdemasking ofcompletioncleaning SQM
HPLsingleleafhingeddoor
ProvidingfabricatingandfixinginpositionogHPLdoorcomprisingoflocking handlesand dropdownbottomsealandaluminiumframe
AluminiumOpenable2PanelSlidingWindow
Nos
Providingfabricatingandfixinginposition2trackcolouranodisedextruded aluminumsectionsofJindalorequivalentapprovedmakeforslidingwindows openablecomprisingofouterframe(035kg/rm),shutterframe(050kg/Rm), glassshutter--(040kg/Rm),mullionforouterframe(055kg/Rm),locking handlesandpullhandleforeachshutter,onepairSS frictionhingesforeach shutterand5mmthickclearfloatglassModiorwiredglassorequivalent with neoprene/rubbergasketwithhinges,lockingarrangementandwooden encasementwherevernecessaryincludingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan 20micronsetc completeasdirected SQM
AluminiumOpenableLouveredWindow
Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium heavysectionsJindalorequivalentmakeforlouveredwindows,openable comprisingofouterframe(035kg/rm),louveres(050kg/Rm),mullionforouter frame(055kg/Rm),rotatingknob,includingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan
Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium sectionsofJindalorequivalentapprovedmakeforfixedwindowsFixedglass windowcomprisingofouterframe,shutterframe,glassshutterandlocking arrangements
Notes:
1)Thecontractorwillgivea10yearsguaranteeoftheworkundertakenon Rs100/-Stamppaperontheapprovedformatdulyregistered
2)Tenpercentamountofvalueofworkswillberetainedfortheperiodoffiveyears fromthedateofactualcompletionofthework,willbereleasedprogressivelyat fourpercentaftertwoyearssubjecttoattendinganyrectificationofdefectsand balanceamountsbytheendoffiveyears
3)Allworktobedonethroughspecialistwaterproofingandstructuralrepair agenciesshallbeundertakenonlyontheapprovaloftheArchitect
Providingandapplying70mmto75mmthickproprietarybrandcementbased waterproofing(boxtype)forbottomRCCraftslabandsidesofRCCwallsofwater tanks,septictanks,effluenttreatmenttanks,etc including providingleakproof treatmentby injectiongrouting toconcretemembersat10mcentresinboth directionsandalsoatallconstructionjoints,andprovidingandfixing20mmto 25mmthickroughShahabadstoneorotherapprovedstonetilessetin20mmthick
1:3waterproofcementmortarandfinishingthebylaying/plastering,with20-30 mmthickC:Min1:3withwaterproofcompound(Contractortogivecomplete specificationsforwaterproofingsystemheproposetocarryout)
ProvidingandlayingwaterproofinginWCandbathroomincludingBB cobainall positionconsistingofspecialisedapprovedwaterproofingcompoundandmaterial asperspecificationswithallleadandlift
Providingandlayingcementbasedwaterproofingtreatmenttoterracewithbricks batslaidinrequiredslopetodrainthewaterforanyspanaftercleaningthe base surfaceapplyingacoat ofcementslurryadmixedwithapprovedwaterproofing compoundandlayingthebrickbatsonbottomlayerinC:M1:5admixedwith approvedwaterproofingcompoundfillinguptohalfdepthofthebrickbats,curing thislayerfor3daysapplyingcementslurryoverthislayerjointingofbrickbatswith C:M1:3admixedwithapproved waterproofcompoundandfinallytopfinishingwith average20mmthicklayersofcementmortaraddedwithjutefiberat1kgperbag includingfinishingthesurfacesmoothwithcementslurryadmixedwithapproved waterproofingcompound
Thefinishedsurfaceshallbelinedwithfalsesquaresof300mmx300mmor preparingthesurfacetoreceivewhitechinamosaicflooringonit(costtoinclude whitechinamosaicflooring)andmakingthejunctionsattheparapetroundedand taperedtowardstopforrequiredheight,withdripmouldatthejunctionofthe plasterandparapetincludingcuringbypondingtestetc complete Average thicknessofbrickbat200mm
WaterProofingChajja
SQM
SQM
SQM
Providingandapplyingwaterproofingtreatmentoverchajjausingproprietary cementbasedsystemlikeIndiaWaterproofingusingbrickbatsof50mmormetal no2,averagethicknessoftreatment50mm,finishedwithsmoothcementfinish withfalsetilemarks,includingbreaking/removingexistingwaterproofingand cartingawaythedebrisetc complete SQM
Tilejointfilling
Providingandfillingcementbasedtilejointsealingcompound(JohnsonBalGrout orequivalent)inbath/WC/toilet/flooringtilesincludingrakingoutoldloose jointingmaterial,curingetc complete
Gapssealing
Providingandfillinggapsbelowdoorframes aroundNahanitrapswith Roffe-grout-GPorequivalentincludingcleaningthesurfaceofallloosematerials curing,mixingaspermanufacturer'sinstructionsetc complete
ProvidingandfixingLeadFlashing750mmoverChajjashallbehoused approximately300mmabovechajjainamortarjointofadjoiningmasonrywall,this sheetctshallbeslopingoutwards Fasteningdown –Thesheets,shallbe fastenedwiththebestSSorBrassscrews/boltsandleadwashersAllen’s,Fisher orotherapprovedfasteningsasdirectedbytheConservationArchitect Thelead sheetingshallbegoodmilledleadnotlessthan10Kg/Sqmbenttotheshape fastenedintothewall groove20mm,withbrass/sswallhookswithjointsatright anglestotheflowbyadripwithaproperlap,iflevelspermit,orby75mmjointsof
SECTION-III: CARPENTRYANDBUILTINFURNITURE
Notes:
1)CarpentryandJoinery,forpartitions,tables,cupboards,storageunits,desks, labfurniture,museumdisplayfurniture,officefurniture,auditoriumandlecture theatrefurniture,doors,windows,skylights,falseceilingetc
2)Forallcarpentryandfurnitureworks,thecontractorshallsubmitshopdrawing foreachitemofworkindicatingthesectionofwoodits joinerydetailetc Whereverpossiblewoodenpinsshallberesortedtoforconnection Alternatively stainlesssteel/brass,screwscouldbeused Noothernails/screwsshallbeused foranyfastenings,etc
3) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials neoprenerubbergaskets screws,etc
4)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
5)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
6)Ratesforrepairsaswellasprovidingandfixingofnewcarpentryitemsand furnitureinthissectionshallbeinclusiveofalltheitemsofhardwareandfittings requiredandnoextrashallbepaidtothecontractortowardsthecostofhardware/ fittings
7)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:
8)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)
9)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand
10)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)
11)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized
12)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete
13)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor 'DORMA'TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect
14)BrassoxidizedBabylatches 75mmlongwith25mmx8mmthickboltcomplete withknob,Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal
15)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper springloadedwithrubberbushandfoot release
16)PlainMorticelocks6leversLatchBoltofDorma/Godrejorapproved equivalentmakeequivalentwithbrassbodyandchromeplatedflatplatetoedgeof doorincludingfixingtotimberoraluminiumshutterframesetccomplete
17)Sameasaboveitem(16)butwithdeadlock
18)3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)
19)Doorbufferwithrubber/PVCbushshutterorwallmounted
20)Providingandfixing andrepairrateswillalsobeinclusiveofaldrops,handles stopperetc allcomplete
PartitionWalls
Providingandfixingfullheight50mmthickHPLpartitionwallsofheight2100mm includingallfixing SQM
InbuiltStoneseats SQM
Providingandconstructinginbuiltmasonryandroughkotahseatsasshownin architecturaldrawingsalongwithacladdingofBluecolourterrazzo(make:Bharat FlooringsandTilesPvt Ltd -Premiumterrazzoseriesorequivalent),laidona bedof1:4cementmortarincludingneatcementbacking,fillingjointsandwhite /colouredcementslurry,curingandcleaningcomplete
StainlessSteelBenches
ProvidingandfixingperforatedSSsheet(SS304)benchofapproveddesignwith SSpipeframingand3mmthickperforatedSSsheetpanelsasshowninthe architecturaldrawingswithnecessarybolting/weldingandfixingontilesurface withanchorfastenerbolts,etc complete
Steelamphitheatre
Providingandfixingwithallthebaseplatesandnecessaryjoineriesandbolts
TOTALOFSECTION-III
SECTION-IV: MISC.
Notes:
1)Rateshallincludeminorcivilwork,scaffolding,electricalworks,dismantling, liasoningcost,steelitems,etc
2)Thequotedpriceshallbeinclusiveofcentralexciseduty,VAT,octroiandservice taxandallotherapplicabletaxes Thisquotationshallnotbesubjecttoprice variationcost
3)Thecontractorshallmakenecessaryarrangementstoprovidesuitablelockable weatherproofstoragespaceforthematerialsandshallalsostacktheexisting dismantledmaterialinasafesecureplaceforthedisposalofthemunicipal authorities
4)Thecontractorshallincludeinthequotation60monthsfreemaintenance,which willbecommencedfromthedateofcompletionofproject
5)Thecostshallbeinclusiveofallpreparatoryworkandnoextracostwillbe providedtowardsthisitem
7) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc
6)Forallworksinthissectionasspecifiedbytheconservationarchitect,the contractorshallsubmitshopdrawingforeachitemofworkindicatingthesections materials,its joinerydetailetc Whereverpossiblewoodenpinsshallberesorted toforconnection Alternativelystainlesssteel/brass,screws/boltscouldbeused Noothernails/screwsshallbeusedforanyfastenings,etc
8)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
9)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
FabricationandinstallationofInformationSignasspecifiedinthedrawings
Providing&fixinginposition inaluminiumextrudedbrown anodizedsectionwithlettersinvinylonbothsidescoveredwithacrylicsheetand asperapprovedsamplebyArchitectfixingasdirected
i)Castirontreegrating,paintedwithanticorrosionprimerand2coatsof polyurethane/epoxypaintinapprovedshade,tobefixedontoconcretebaseas shownindrawings Ratetobeinclusiveofbasegrouting,providing,fixing,nuts, bolts,welding,painting,etc complete
ii)GraniteStonecobblestoneedgingaroundthetreebase,withwhiteround pebbles/withgravelbedinsideasindicated
TOTALOFSECTION-IV
SECTION-V: ELECTRICAL
ThisitemisworkedoutbytheElectricalConsultant
Forthepurposeofthiscourseanapproximateamountisbudgeted
Supply,Installation,TestingandCommissioningofEarthingstationasperIS3043 consistingof40mmGI3000mmlongpipe suppliedwithfunnelattopincluding saltcharcoal masonrychamber testlinkbox hardwareincludingexcavationand masonryworkwithcastironcoverforthechamber
Supply&Layingof followingsizesofstrips &wiresfromearthingchamber/Gridto theelectricalequipment&terminatingthesame Theportionofthestripunder groundshallbelaidatadepthof600mmandonsurfaceshallbefixedwith spacers&clamps&alsoonTray Excavation&allcivilworktobeincluded 25mmx3mmGI stripforDistributionBoard(FirstDistributionBoardinacluster ofDistributionBoards)
8SWGGI EarthingwireforLighting&PowerDistributionBoard
Supply Installation testing andcommissioningof3phaseenergymetersuitable forunbalanceloadandincludingnecessarycutoutandjumperwiresetccomplete aspersupplycompany'srequirement
Supply,Installation,testing andcommissioningofTPNMCB16A andincluding ncessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement
Supply,Installation,testing andcommissioningofTPNMCB40A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement
Supply,Installation,testing andcommissioningofTPNMCB32A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement
Supply&InstallationofstandardmanufacturersDistributionBoardforLighting It shallbeastandardBoardwithdoubledoor&suitableforrecess mounting&shall beasfollows Scopeincludesmountingarrangementincludingnecessarysteel, hardwareetcWiresinDB tobeproperlydressedwithbuttontapeandwithlugs, labelsetc
Incomer40ATPNMCB-1No 40A,30mA,2P,RCBO-3NosOutgoing 6/10ASP MCB-24Nos
(LDB)
Supply,Installation,Testing&CommissioningofPVCArmouredCablefixedto walls,Ceilingswithclamps,spacerssaddlesorlaidinreadymadetrenchortiedto cablestraywithcableties,tagsetc asfollows 1100VgradeasperIS Installation,Testing&Commissioningofcables(onwalls,trays) PVCinsulated, 1100Vgrade,steelarmoredasperIS1554withlatestamendmentincluding spacers,saddles,tags, etcThecablesto beproperlydressed
4Cx16SqmmALAYFY
3Cx10SqmmALAYFY
4Cx10SqmmAYFY
3Cx4SqmmAYFY
3Cx6SqmmAYFY
3Cx25SqmmAYFY
TerminationofcableswithHeavydutySiemenstypeglands&lugs Lugsused shouldbeCopperforcoppercables&Aluminiumforaluminiumcable Scopeto includeallmaterial&labourincludingpropertools,Insulationtape
4Cx16SqmmALAYFY
3Cx10SqmmALAYFY
4Cx10SqmmAYFY
3Cx4SqmmAYFY
3Cx6SqmmAYFY
3Cx25SqmmAYFY
Pointwiringforlight,bellpoint ScopetoincludecircuitWiringforlighting&the lightswitchboardwithswitches&furtherwiringtolightpoints Theswitchboard shallberecessmounted/surfacemountedofGIstandardasperthesupplier The pointWiringshallconsistof3x15Sq mmcopperwire PVCinsulated 1100V gradeinPVCconduit/PVCcasingcaping Thewires&conduitsshallrunfromthe switchboardtotheindividualpoint&circuitwiringshallbeof3x25mm2copper wirefromdistributionboardtothe switchboard Modularplatetypeswitchestobe used6ASwitchSocketonswitchboardtobeincludedInmajorityofthecasesthe lightsaregroupswitchedfromtheDistributionBoardinwhichcasethewireshall be3x25mm2 AllwiresshallbeFRLS
PrimaryLightPointwiringofaveragelengthupto5meterslengthofwire
PrimaryLightPointwiringofaveragelengthupto55to10meterslengthofwire
PrimaryLightPointwiringofaveragelengthupto105to15meterslengthofwire;
PrimaryLightPointwiringofaveragelengthupto155to20meterslengthofwire;
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto5metersof lengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto55to10 metersoflengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto105to15 metersoflengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto155to20 metersoflengthofwire3x15sq mmwires
FanpointwiringshallbesameasPrimarylightpointpointwithindividual controlWireofsize3x15sq mmsizeshallrunfromtheswitchboardtothefan pointthroughPVCconduit/PVCcasingcaping ThecircuitfromtheDBtothe switchboardshallbe3x25sq mmwiresSpaceforregulatortobeprovidedinthe switchboard Upto5Metersof lengthofwire
FanPointwiringwiringlength55to10meterlength
FanPointwiringwiringlength105to15meterlength
FanPointwiringwiringlength155to20meterlength
Exhaustfan/WallFanpointswiringshallbesameasPrimarylightpointwith individualcontrol&6Asocket&top@thefanpoint Wireofsize3x15mm2size shallrunfromtheSwitchBoardtothefanpointthroughconduit Thecircuitfrom theDB totheSwitchBoard with3x25mm2wire
Pointwiringfor6Ampswitchsocketpoint Scopetoincluderunningof3x25mm2 copperwire,PVCinsulated,1100VgradeinPVCconduit Wirestoberunfromthe PowerDistributionboardtotheIndividualsocketsupto4socketscanbeloopedon onecircuitWorkstationRawpowerAllwiresshallbeFRLSWiringlengthupto5 meters
6Asocketpointwiringlength55to10meters
6Asocketpointwiringlength105to15meters
6Asocketpointwiringlength155to20meters
Pointwiringfor6/16Amp switchsocketpoint ScopetoincludecircuitfromDB toindividualpoints Conduit accessories&wireswith3x4mm2copperwiretobe laidfromDBtoindividualsocket TwosocketpercircuittobeconsideredAllwires shallbeFRLSWiringlengthupto5meters
6/16APointwiring55to10meterlengthofwire
6/16APointwiring105to15meterlengthofwire
6/16APointwiring155to20meterlengthofwire
6/16APointwiring205to25meterlengthofwire
Supply,Installation,Testing&Commissioning6Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections
Supply,Installation,Testing&Commissioning6/16Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections
Supply,Installation,Testing&Commissioningof20AReyrollPlugsocketwith3pin MetalTop,inmetalboardwith20ASPMCB
Supply,Installation,Testing&Commissioningof225mmDia ExhaustFanwith connection
Providingandinstalling,connectingandcommissioning32ATPNSFUwithHRC
Fuse
ProvidingandlayingTwopairTelephonecableinexistingconduit/casingcaping
Providingandinstallingoutlet fortelephonecable
Providingandinstallingcelingfan1200mmsweepwithfivestepselectronic regulator
Supply&InstallationoflightfixtureswithSigmaBallastincludinglamps,junction boxes,downrod/supports,hardwares rawlplugs,wires/cablesetc asrequired andconnectingittoswitchboards
SupplyandInstallationofPortableEmergencyLightonBatterysuitableforupto10 hours Installite/Canaramake Mountingarrangementforlamptobeincluded
1x18WBracketlight
WST71150withGI waterpipearm1mlongweldedtothecap
WFZ42250
WIF22228SGW
Liasoningchargeswithrespectiveauthoritiesforshiftingofpointofelectrical serviceandothers
Excavationinoutsidesoilincludingrefilling
Supplyinganderectingsteeltubulerpole1651x1397x1143mmthickwith 45x45x365mmthickand(56x27x27mm)respectively11mtrs LongasperIS 2713withtestcertificatefrommanufacturercompleteerecteddulypaintedwithtwo paintsofredoxideandtwocoatsofaluminiumpaintcompleteerectedinposition withMS baseplateof30x30x06cmsthickweldedatthebottomandsuitable polecaperactedwithsetscrewsorwieldedcompleteerectedCC foundationand plinthJunction/Loopingboxincluded
Note:Foritemnos 16,17and18,ratesshouldbeinclusiveofa
Supplyinganderectingcentrifugalwaterpump(Monoblock)withCI impler, primingfunelcockandcommonflangemountedonacommonshaftofinduction motorof400V3phaseAC supplyofminimum3H P Motorcapableof dischargingwater600to170litesperminutesat125to275meterstotalhead fromallclauseswithfoundationandwith50mmsuctionand50mmdelivery water pumpshallbeconfirmingtoIS1520complete(Crompton/Kirloskar/Grundfosor anyotherequivalentmake)
Waterlevelcontrollerwithnecessaryprobesforcontrollingmotorforcutoffwhen uppertankwaterlevelisfull,whenwaterlevelinthetankcomestopredetermined levelpumpshallstartautomatically When waterlevelinthesuctiontankisbelow thewaterlevel,thepumpshouldnotstart Alsopumpshouldnotrundry The controllershallhavemanual,autoswitchesandselectionofpump Therateshall includenecessarywiringwithcopperwires
DOLStartersuitablefor3HP motorincludingoverload
Providingandfixing25mmPVCconduits/Casingcapingincludingallfittings
Note:
Allcataloguenos referredinvariousitemsofsanitaryfittingsareasperHindustan /ParrywareSanitarywareCataloguesandallfixturesareJaguarContinental series
Providingandfixingapproved'Indian make white/colouredglazedvitreous chinawarewallhungEuropeanwaterclosetcisternincluding-
a)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
b)CIchairsupportsforthewatercloset
c)Whiteorcoloured solidplasticseat&cover veryheavyqualitywith rubber buffersfixedtotheclosetwithCPbrasspillarhinges
100mmdiaconnectorpipefromPtraptothejunctionofthesoilstackonexternal faceofbuilding
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazed'vitreous chinawarewash'handbasincountertoporsuitableformountingbelow'counter comprising:
a)White/colouredglazedvitreouschinawareovalshapedwashbasin,size 550mmx400mmwithsupportingMSorCIbrackets
b)1No15mmCPbrasspillarcockwithallfittings
c)1No32mmCPcastbrassbottletrapwithextensionpiecetowall,wallflange withrubberadopterwasteconnection
d)1NoheavyqualityCPbrassangularstopcock15mmsizewithCPbrassflexible connectorpipe Thesupportingbracketshallbeprovidedwith3coatsofapproved paintofapprovedshade
Providingandfixingvitreouswhite/colourchinawareurinalcomprising
a)Largeflatbackwallhungurinalsize610x400x380mm
b)flushingtankof10ltrssupplyingto3urinalswithallfittings
c)CPbrasschromiumplatedflushpipingfromflushvalvetourinalterminatedwith a15mmscrewedspreader
d)32mmdomeCPcastbrasswaste
e)32mmnbCPcastrunningtrapwithextensionpipetowall,wallflange,rubber adopterforwasteconnection
Providingandfixing15mmsizeCPbrassbibtapISImarkedheavyqualityonGI lineswithflangeandCPconnectorofapprovedmake
Recessedtypewhite/colouredtoiletpaperrollholdersize150mmx150mmin vitreouschinawarewithwoodenrodandspringincludingcuttingrecessinwall settingtherollholderincementsandmortar1:3reinstatementofwallsurfaceto originalconditionsetc complete
ProvidingandfixingapprovedheavyISImarkedmakeCPbrass spoutsforbath with20mmthreadsoutsideand15mmthreadinsidecompletewithtaperedwall flange
Size15mm
ProvidingandfixingapprovedISImarkedmakeheavyqualityeasycleanvariety screwdownCPbrassstopcocksonGIlines,withfemalethreadedends
Size15mm
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareOrissawaterclosetcomprising:
a)Orissapansize580mmx440mmwithboxriminletwithPorStrapasrequired
b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareindowesternwaterclosetcomprising:
a)Indowesternfloormountedsize600mmx460mmwithboxriminletwithPtrap asrequired
b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
100diaCI connectorpipefromPorStraptothejunctionofsoilstackonexternal faceofbuilding
Providingandfixingwhiteglazedvitreouschinawareurinalpartitionssize860x 315fixedtowallwithCPbrassbolts,nuts&expandableanchorfasteners
ProvidingandfixingISImarkedmakeSSsinkwithintegraldrainboard,single pressingofsize930mmx460mmwithsupportingbracketsCPbrasswaste,bottle trapetc complete
SupplyandfixingHindustanPilkingtonmakemirrors,6mmthickwithplainor bevelededge,8mmthickplywoodbacking,4NosCPbrassscrewswithCPbrass capsscrewedtorawlplugsembeddedinwall
Supplyandfixing40mmCPbrasswastecouplingwithrubberplugandCPchain
Providing&fixinginpositionheavytestedscrewdown15mmCP brasssinkcock withraisedJshapedswingingspoutwithflangeofapprovedmake
Providing,laying,fixingjointingwithscrewedjointsusingteflontapeGIpipes heavyqualityconformingtoIS1239includingallfittingssuchassockets,unions reducers,longorshortbends,elbows,nipples,flanges,checknuts,clampsetc testingthepipesandspecialsandpaintingthepipesandfittingswithonecoatof approvedprimer&finishingcoatsallasperspecificationsForpipesinexposed conditions:
Providing,laying,fixingjointingwithscrewedjoints'C'classheavyGIpipes conformingtoIS1239includingallfittings,testing,paintingwithbitumasticpaint protectionwrappingwithHessienfacedpolyethylenetaping&paintingcompleteas perspecifications Forpipelineslaidbelowgroundlevelandlaidinchasesin walls Therateincludesexcavationandcuttingchasesinwallsandreinstatement)
Providing,fixingandtestingheavyqualitygunmetalorbrassballvalvewith screwedends20kgmclassonGIorcopperpipelines(Leader/ZOLOTOmake)
ProvidingandfixinginpositiontestedheavyqualityISImarkedfullwaygunmetal gatevalveofneworequivalentmakehavingbothendsscrewedfemale conformingtoIS778:1984etc complete
Providing,erecting,fixingandcommissioningPVCoverheadwatertank(BMC approved)includingmakingofproperplatformasperconsultant'sdirection,lifting oftanktoterracefloorlevel,placingoftankonplatforminproperalignment, makingofinlet/outletconnectionsasperbye-lawsetc complete i)5000litrescapacity
Providing,fixinggunmetalnonreturnvalveofapprovedquality
ProvidingandfixingapprovedISImarkedmakeCIflangedwatermetersdirect readingtypecalibratedinlitres&kilolitrestestedandapprovedbyMCGMwithdirt box(strainer)includingmakingnecessaryflangedjoints,testingetc complete 40mmsize 50mmsize
Constructingbrickmasonryvalve&meterchambersin230mmthickbrickmasonry incementmortar15usingfirstclassbricksconstructedoverabedof150mmthick cementconcrete1:2:4plasteringinsideoutsideandallexposedsurfacewith 20mmthickcementmortar13,finishing'insidewithafloatingcoatofneatcement providing&fixingCIframe&coversize, weightmentionedbelowpaintingallCI itemswith3coatsofapprovedbitumasticpaintetc complete Chamber600x600mmclearinsidewith600x600CIframe&coverweightingnot lessthan72kgms Depthofchambernotexceeding1000mm
ProvidingStructuralsupportforpipelinesusingchannels tees angles flats& platesfabricationbycuttingthreading&weldingifrequired,applyingonecoatof redoxideprimerandthreecoatsofsyntheticenamelpaint,includingnecessary boltsnuts,washeretc asrequiredbytheEngineer-in-charge Theweightofthe supportshallbecalculatedonthebasisofcatalogueweightsofsectionsused (weightofbolts,nutsetc willnotbeconsidered)
Providing&fixingbrassfloatvalveswithbrassrodandcopperfloat suitableto withstandapressure2 kg/sqcm
50mmnb
40mmnb
Excavationintrenchesforpipelinesofrequiredwidthanddepthasdirectedby Engineer-in-chargeincludingtrimmingbottomandsides,excavationforsockets includingrefillingwithselectedexcavatedmaterial(afterlayingofpipeline)in 200mmlayers wateringconsolidationdisposalofsurplusearthwithin50metc complete
Inordinarysoil(forCIpipelineslaidoutsidethebuildingonly)depthnotexceeding
15m
-Do-insoftrock
ProvidingandfixingbestIndianmakeCPbrassairvalveswithisolationvalvefixed onGIlines
15mmnbairvalvewith15mmisolationvalve
20mmnbairvalvewith20mmisolationvalve
Providingconnectionstoequipments(Kitchen/Laundryetc includingprovisionof controlvalve,runningjointwithunionetc complete
65mmconnections
50mmconnections
40mmconnections
32mmconnections
25mmconnections
20mmconnections
15mmconnections
SupplyingandinstallingBourdentypepressuregaugesrange0to20Kg/sqcm calibratedbothinpsiandkg/sqcm with10mmbrassgaugecocketc complete
Providingandfixingpipesleevesupto600mmlong,cutfromheavyqualityMS pipesconformingtoIS1239or3589(dependingonsizeofpipewithMSflange conformingtotable13ofIS 6392onbothendsanda6mmpuddleflangeatthe centreofthesleeve,allflangesweldedtopipe,fixingthesleeveinpositionbytack weldingtoreinforcementetc complete
40mmnb
50mmnb
65mmnb
80mmnb
100mmnb
ThisitemisworkedoutbytheServicesConsultant Forthepurposeofthiscoursea
Providingandfixingcastiron traps of selfcleansing design with watersealnot lessthan50mmwith or without vent,including setting the trapin1:2:4cement concreteetc complete Thetrapshall be P' or S'type as required Trapwith 100mm inlet and100mmdiaoutlet
Asinitem31buttrapwith75mmoutlet
Asinitem31buttrapinPVC
Asinitem32butwithPVCtrap
Providingandfixingstainless steel gratingof 18 gaugethick,withcircular perforationofapprovedpatternoverCItraps Thegratingshallbeofsize100mmx 100mmorcircularof100mmdia(asdirected) and shallbesetin cement,sand mortar1:3etc complete
-Do-gratingofsize150mmx150mm
Providing, fixing, jointingand testingPVCWCpanconnectorofapprovedcolour with or withoutvent horn all as perrequirementsofEngineer-in-charge Size 100mmi/d-Length300mmto400mm
Supplying,laying,fixingjointing&testingheavyISImarkedcastiron spun soil pipes/centricastpipesincludingallfittingswithorwithoutinspectiondoors,vents, cowls at topetc jointing with leadcaulked joints all as perspecification and as directedbyEngineer-in-charge
150mmi/d
100mmi/d
75mmi/d
65mmi/d
50mmi/d
Providing, laying, jointing with screwed jointsusing teflon tape GI pipesof classTataorZenithconformingtoclassheavyofIS1239withallfittingstestingthe piping, painting with 2coatsofbitumasticpaintwrapping with Hasseinfaced polyethylenetapeintwo layers and againpaintingwith2coatsofbitumastic paint Therateincludesforcuttingchasesinwall&floorsforembeddingthepipe andreinstatementofsurfacetooriginalconditions
50mmi/d
40mmi/d
32mmi/d
Providing and fixing inposition cast iron rain water inlets withgravelguard anddometypegratingspeciallycastgenerallyconformingtodrgs
Inletfor:
150mmi/dpipes
100mmi/dpipes
Providing and fixingleadsheet flashing madeoutof3mmthickleadsheets settinginalayerofcoldbitumenetc complete Thesheetshallprojectatleast 150mmallaroundthepipeand shallbetuckedintothepipeatleastby100mm
150mmi/dpipes
100mmi/dpipes
ProvidingandfixingMSsupportsforpipesfabricatedfromMSflatsanglesand platesincludingfixingthebracketstowalls,slab,beametc withanchor,fasteners 12mm'U'or'J'boltsforfixingthepipestoclamppaintingwithonecoatofprimer andtwocoatsofapprovedpaintetc complete
Providingandlayingcementconcrete1:2:4forbedding envelopeshaunchesetc forthepipesincludingmixingplacingformworkcuringetc complete
SupplyinglayingfixingjointingandtestingPVCdrainagesystem(SWR)including fittingswithorwithoutinspectiondoors,vents,cowlsetc allasdirectedby engineerincharge
110OD 75OD
ProvidingandfixingPVCplainor multi floor traps of selfcleansingdesignwith watersealnotlessthan50mmwithorwithoutventincludingsettingthetrapsin cementmortaretc complete Trapswith125mminletand75mmoutlets
Providingcleanoutsincastiron drainpipingcomprisingGIheavyclasssocket andscrewed plug,connectingCI pipewithleadcaulked jointetc complete 150mm
Supply,laying,jointingandtestingPVCpipesincludingallmouldedfittings conformingtoIS4985(10Kg/sqcmvariety)etc complete
ProvidingandfixinginpositionheavyISImarkedlongarmCI nahanitrapofIS 1729weighing9kgofNecoorEquivalentmakeofsize100x75x500mmdiaoutlet includingembeddingonflooringatrequiredlevelwithM150cementconcreteall aroundandbelowthetrap,supplyingandfixingbrassCP squaregratingofsizeof 150x150mmwithbrassCP coverplateasspecifiedetc complete
Providing,fixingandjointinginproperalignment&positionheavyISImarked 50mmdia CI pipeofNecoorEquivalentforventconformingtoIS1729withall necessaryfittings,likeoffset,bend,cowletc includingerectionofscaffoldingat requiredlevel,makingholesinwallsasrequired,fixingofpipe&fittinginposition, leadjointing/fillingofjointswithCM1:3(onlyonapprovalofconsultant), reinstatementofsurfacesetc complete
Providing,fixingandjointinginproperalignment&positionheavyISImarkedCI CentripipesofKapilanshorEquivalentmake(withinbuildingline)fordrainage conformingtoIS3929of150mmdiameter sizewithallnecessaryfittings,like offset bend etc includingexcavationuptorequiredlevel makingholesinwallsif required,layingofpipeatpropergradient,leadjointing/fillingofjointswithCM1:3 (onlyonapprovalofconsultant),reinstatementofsurfacesetc complete
Providingandconstructing300x300mminternalsizebrickmasonrygullytrap chamberincludinglayingof100mmthickPCC1:3:6inbed,115mmthickbrick wallsinCM1:5,fixingofglazedstonewaregullytrapofsize150x100mm, makingconnectionofwastewaterpipetoit,plasteringinsidethechamberwithCM 1:3toformhopper,fixingofheavyCI coverwithframeweighingnotlessthan7 kg inPCC1:2:4&makingflooringlevelontopetc complete
Providing,layingandjointingISImarkedfirstquality‘A gradesaltglazed stonewarepipe&bend,includingexcavationtothelevelofrequireddepth,laying of100mmthickPCC,placingofpipeonPCCasspecifiedatproperalignmentand gradient,sealingthejointswithtarredgasketofhemporropeyarn,caulkingwith cementmortar1:2,testingofpipeline,encasingofpipeasspecified,curing, refillingetc complete
i)100mmdia
ii)150mmdiafordepthbetween045and060Mtrs
iii)150mmdiafordepthbetween060and100Mtrs
Providing&fixing150mmdiameterISImarkedfirstquality‘A’gradesaltglazed stonewaresewertrapasspecified
i)150mmdiameter
Constructingbrickmasonryinspectionchamberofsizeof900x450mmanddepth asmentionedinitw\esmbelowincludingexcavationupto requireddepth,layingof 100mmthickPCCfoundationbedin1:3:6mix,230mmthickbrickworkinCM1:3, 20mmthickplasteringofwallsinside&outsideasspecified,makingofsmooth channel&haunchinCM1:2,150mmthickPCCcopingontop,fixingofCI manholecoverofNecomakeweighingnotlessthan75kg,backfilling,removalof surplusearthasspecifiedetc complete
i)Depthbetween045and060m
ii)Depthbetween060and100m
ForallItemsinallSections:Rateshallincludetransportation,loading/unloading,providing/supplying/laying/fixing/installing/ fabricating/testing/commissioningetconsite RateshallalsoincludealltaxessuchasVAT,excise,salestax,octroi,etc
SECTION-I: SitePreparation&Cleaning
Cleaningandclearingthesiteofallrocks,boulders,brick-bats,stone,bushes, shrubs,etccomplete,asdirectedbythearchitectforstartofconstructionactivity
SECTION-II: CIVILWORK
Note:
1)TheitemsgivenbelowshallbeasperSectionA""Earthwork,MetalPacking& SubsurfaceDrainage"ofthespecifications
2)Rateforexcavationshallincludedewateringduringtheexcavationincluding shoring,struttingetcandkeepingitdryduringexcavationandconstruction
3)AllearthworkshallbecarriedoutasperConservationArchitect'sinstructions andsafetynormsasperrelevantIScode Therateshallincludeallscaffolding andmeasuresforcordoningoffareasduringdismantling,providingsignboards etc
4)Alldebrisandscrapmaterialsfromearthworkshallbecontractorspropertyother thanthatwhichisreusedforback-fillingetc andthisdebrisandscrapmaterials shallberemovedawayfromsiteimmediatelyonhisown Thecontractortogive rebateinratesagainstmaterialsandscrap/debrisfromsuchdismantledwork whichshallbecontractor'sproperty
5)Forallearthworkitems,thecontractorshouldcarefullystackallexcavated materialatsiteaspertheinstructionsoftheConservationArchitect Alldebris associatedwiththeearthworkshouldhoweverbedisposedoffbytheContractor
6)Themeasurementofexcavationshallbetakenincum asperrectangular trenchofbottomwidthofconcretemultipliedbyverticaldepthoffoundationfrom groundeventhoughcontractormighthaveexcavatedwithslopingside/fulllength trenchforhisconviency
Surfaceexcavationandexcavationforretainingwalls,basement,watertanks, effluenttreatmenttanks,etc includingbackfillingofapprovedexcavatedmaterials infoundations, &behindretainingwallsaftercompletionofwaterproofingetc wateringandconsolidating,cartingawaysurplusearth, includingpreparingthe surface (Note:Allbackfilling&spreadingofearthshallbecarriedoutinlayersnot exceeding200mmandcompactedto90%ordinaryproctordrydensity) 350 CUM
Fillinginplinthandinotherplaceswithapprovedmurumbroughtfromoutside, includingwateringconsolidatinginlayersnotexceeding200mmby8-10tonnes roadrollerorotherapprovedmechanicalequipmentetc completeasdirected
Anti-termitePreconstructionTreatment:(AsperIS:6313Part-III)(Note: Anti-termitetreatmentshallbecarriedoutthroughspecialisedagencyreputedin PestControltreatmentandapprovedbytheArchitect Thecontractortogive10 yearsguaranteeonasuitablebond)
Providingpost-constructionalanti-termitetreatmentbydrillinginholesatthe junctionsofwallsandflooringandinjectingchemicalemulsion,wallsprayanddoor framestobedrilledandsprayedcompleteusingapprovedchemicalsattherateof 5litersofemulsionconcentrateofonepercentconcentrationofCHLORPYRIFOC 20%EC,ISIapprovedconforming(IS8944),Includingtreatmentofwoodfor termites,borers,wetrotsanddryrots Coveredfloorareashallbemeasuredfor payment ( )
Providing,chasing,inserting/layingDampproofcourse50mmthickM-20cement concretelayerandbitumenusingcementwithapprovedwaterproofingcompound attherateof1Kgper50kgofcementetc complete
Note:
1)TheitemsgivenbelowshallbeasperSectionB"Concrete-Plain&Reinforced" ofthespecifications
2)ForsmallconcreteonapprovalofConservationArchitect,weighbatched concreteasperdesignmix,inmanuallyormechanicaltypeoperatedweigh batcherdialtypeormechanicaltypeofminimumcapacity650Kgsshallbeused Weighbatchershallbecalibratedregularly
3)Forallmajorconcretepours,Contractorshallusereadymixedconcrete(RMC) ofUnitechPrefabLtd orM/s Larsen&ToubroLtd approvedAgencies Only53 gradecementshallbeusedinRMC Aggregatepropertiesandgradingdesign mix,quantityofsuperplasticiser,settingtime,amountofslumpatthepouringsite shallbegotapprovedbeforeitsuseineachmajorconcreting
4)Concretemixproportionwillbebasedon50kg weightofcementbags deliveredatthemixer
5)TheContractorisentirelyresponsibleforthedesignofconcretemixes The designishowever,tobeapprovedbytheArchitect
6)ConcreteM-20/20meansconcretemixM-20gradeusingmaximumsizeof coarseaggregates20mm
7)Shuttering,formwork,centeringshallnotbepaidseparatelyandshallconform toSection-C
8)Curingcompoundmaybepermittedonlyforinaccessiblelocations
9)OnlyRiverSandshouldbeused Washingofsandinrotaryscrewtypewashing machinesisamust
10)RatesshallbeinclusiveofcostofSuperplasticiserofapprovedqualityandof approveddosage
11)Ratesshallbeinclusiveofprovidingpockets,holes,inserts,pipes,etc
12)Mechanicalvibrators,internaland/orexternaltobeused
13)AlldefectiveconcreteifapprovedbyArchitect,shallberepairedbythe contractorathisowncost,usingapprovedepoxymortarorPolymermodified mortarasperManufacturer'sspecifications
14)Therateshallincludethecostofapplying2coatsofpolymerbondingagenton allsurfaceofoldornewconcreteatconstructionjointpriortoconcretingagainst thesame
15)Useoffinesandwithpropergradingisamust
16)Screeningofmetal-IandIIforremovingexcessiveflakyunderandoversize material,stonedustetc isamust
17)Onlyapprovedmouldreleasingagentshouldbeused
18)Cleaningofshutteringplatesbymechanicalbuffingaftereveryuseisamust
19)Allconcretesurfacesshallbeformfinished
20)Whereplasteringisspecified,concretesurfacesarerequiredtobehacked immediatelyaftertheremovalofformworkasdirectedbytheArchitectwherever required Additionalrateshallnotbepaidtocontractorforhacking
21)Contractorshouldmakearrangementfortablevibratorforcastingthecover blocksofrequiredsizeandgrade
22)Rateshallbeinclusiveofprovidingcoverblocks Coverblocksshallbemade ofthesamegradeofconcreteofstructuralmemberinwhichtheblocksaretobe used
23)Alljointsinshutteringshallbesealedbyuseof5mmthickcompressible materialgasketsandfixingagent
24)Constructionjointshallbeminimuminnumbersandtheirlocationshallbe approvedbytheConsultant Constructionjointsshallbetreatedproperlywith bondingcoatofapprovedmaterialtobeappliedattheoldconcretebefore commencingthefreshconcretingoperations
25)Informfinishsurfacesthepatternstobeprovidedfortheformworkshallbeas perarchitectssuggestions
26)Allsack-rubbedsurfaceshallbesackrubbedwithwhitecementofsuggested proportionasperArchitectsapproval
27)Allconcealeditemslikeconduits,junctionboxes,fixturesetc shallbelocated asperdetailsandlocationstobeapprovedbeforecasting
NotesforFormwork:
Note:1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications
2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping
3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework
4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed
5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorathiscost
6)Ratesquotedshallbeinclusiveofallformworkatalllevels
7)Rateshallincludeuseof5mmthickcompressiblegasketmaterials fixingagent adhesivetapeandmechanicalbuffingofshutteringplates
8)Onlyapprovedmouldreleaseagentshouldbeused
9)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust
10)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork
11)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect
12)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately
13)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect
14)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection
15)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant
ProvidingandlayingConcreteM20/40usingRMCforall , etc includingsideformsifrequired The rateshallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads& lifts,allfloorsallchargesrequiredincludingtransportation,centering,formwork, compacting rougheningthesurfaceifspecialfinishistobeprovidedandcuring etccomplete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkoffloorslabon gradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes towardsplant&machinery labour allleads&lifts allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc complete (level1at-165m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level2at+015m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level3at+15m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level4at+315m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery labour allleads&lifts allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level5 at+375m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery labour allleads&lifts allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level6at+45m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation shuttering centering formworkasperconditionbelow etc complete (level7at+63m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level8at+675m)
ProvidingandlayingconcreteM25/20usingRMCforfloorslabongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete (level9at+905m)
ProvidingandlayingconcreteM25/20usingRMCfor ongradeincluding finishingthesurfacesmoothetccomplete Therateshallbeinclusiveofalltaxes, towardsplant&machinery,labour,allleads&lifts,allfloorsallchargesrequired includingtransportation,shuttering,centering,formworkasperconditionbelow, etc complete
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes towardsplant&machinery labour allleads&lifts all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes towardsplant&machinery labour allleads&lifts all floorsallchargesrequiredincludingtransportation,shuttering,centering,formwork
-- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
015 -- CUM
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therateshallbe inclusiveofalltaxes towardsplant&machinery labour allleads&lifts allfloors allchargesrequiredincludingtransportation,shuttering,centering,formworkasper conditionbelow,etc complete 015
ProvidingandlayingconcreteM25/20usingRMCforRCCworkof ongradeincludingfinishingthesurfacesmoothetccomplete Therate shallbeinclusiveofalltaxes,towardsplant&machinery,labour,allleads&lifts,all floorsallchargesrequiredincludingtransportation shuttering centering formwork asperconditionbelow,etc complete 015
Providing&layingM30/20 usingRMCforRCCincludingpumpingforfoundation pilecaps,raftslab,column,walls,shearwalls,boxcolumn,retainingwalls,plinth beams,floorbeams,invertedbeams,slabs,staircase,droppardis,chajja, parapets,pergolas,trenchslabandbeamsinstructuralfloors,loftslabsatall levels,lintelbeams/verticalstiffenersetcincludingRCCundergroundwatertanks, septictanks effluenttreatmenttanks overheadwatertanksetccomplete Therate shallbeinclusiveofalltaxes,towardsplants&machinery,labour,allleads&lifts, allfloorsallchargesrequiredincludingtransportation,shuttering,centering, formworkasperconditionsbelowetc complete
Providing&layingConcreteM20/40,usingRMC,inalternatebaysfor includingcompacting,vibrating,curing,finishingtocorrect line&levelwiththeuseofwoodenbottomandsurfacefinallyfinishedwithbrooms asdirectedbyArchitect Jointsofandasprovidedinalternatebaysshallbefilled
ProvidingandconstructingRCCundergroundwatertankincludingexcavationinall typesofsoil refillinginsidesoftank trimming dressing leveling stackingand
i)Rubblesoling230thk
ii)PCC M20/30belowraft
iii)M-25/20RCCworkinraftslabs,sumpbase,beams,RCCwalls,columns,top slabsetc includingunwrotshutteringtoRCwallsatalllevels
iv)TMTreinforcement
v)Waterproofcementplastertoinsideofwatertanks
vi)BoxtypewaterproofingtreatmentforraftandwallsofUGtank
vii)Patentedcementbasedwaterproofingtreatmenttotopofslabs
viii)50mm thk IPStoraftslab
ix)Providingandfixingcastironmanholecovers2nos 600mmdia withlocking arrangements
x)PVCwaterstop150mmdia;embeddedintakeandoutletpipesetc
Providing,erecting,fixingandcommissioningSintexorapprovedequivalent doublelayeredtanksonoverheadelevatedpedestalasdirectedincluding scaffoldingallalliedplumbing,valves,stopcocks,MCGMcertifiedwatertankcap, includingcleaningetc
Notes:
1)TheitemsgivenbelowshallbeasperSectionC:'Formwork'ofthe specifications
2)ContractorshouldsubmitfortheConsultant'sapprovaldesignanddrawingfor allformworkshowingsizesofmemberincludingpropsanditsfoundation consideringRMCbypumping
3)Amockupofformworkforcolumns,typicalcolumn-beamjunction,beams shouldbemadeandonlyafterobtainingapprovalofthemockup,thecontractor willbeallowedtoproceedwiththework
4)Allsurfacesofconcreteelementsshallnotbetreatedinanywayunless otherwiseinstructed
5)Allconcretesurfacesshallhavesmoothandevenfinishoriginallybythemselves withoutanyfinishingorrendering IncasetheArchitectisnotsatisfiedwiththe finishobtained remedialmeasuresforimprovingthemshallbecarriedoutbythe Contractorat hiscost
6)Rateshallincludeuseof5mmthickcompressiblegasketmaterials fixingagent adhesivetapeandmechanicalbuffingofshutteringplates
7)Onlyapprovedmouldreleaseagentshouldbeused
8)Manual/mechanicalcleaningofshutterplatesaftereveryuseisamust
9)Therateshallincludehackingofconcretesurfacerequiredtobeplastered immediatelyafterremovalofformwork
10)Onlynewsteelandplywoodshutteringshallbepermittedforitsfirstuseatsite, anditsnumberofuseswillbesolelywithdiscretionofArchitect
11)Providingcutouts,holes,slits,depressionetc forelectricalfixturesshallnotbe paidseparately
12)Sizeofthepanelsusedforexposedconcretefinishareasshallbeapprovedby theArchitect/consultants
13)Thesupportingsystemforplatformdoorshallbehavingselfalignmentdevices toensureperfectlineandlevel,andverticalityoftheshuttering,stagingtoachieve requireddegreeofperfection
14)Forquickerectionofshutteringandstagingthesystemshouldhavesuitable arrangementformovingentiresetintransverseaswellasinlongitudinaldirections andrails/wheelsonanysuitablearrangementwhichwillbeapprovedbythe consultant
Notes:
1)TheitemsgivenbelowshallbeasperSectionD:'Reinforcement'ofthe specifications
2)CoverblocksshallbeofgoodqualityconcreteM30/10andshallbevibratedon atablevibratortoreducethepermeability
3)Whereverweldingofreinforcementisspecified thesameshallbecarriedout conformingtoIS:9417orIS:2751 Weldingshallbecarriedoutbyapproved qualifiedweldersonly Onepercenttestingofweldsshallbecarriedforalltypesof welds
4)Overweightofthesteelshallnotbeconsideredforcalculatingconsumptionand paymentpurpose IS constantforweightofdifferentdia ofbarsshallbe consideredforpaymentaswellasconsumptionpurpose
5)Columnreinforcementbarsarerequiredtobelappedinthemiddleportionof columnsasperIS13920 Properarrangementshallbemadetosupport reinforcementprojectingabovefloorlevel Similarlylapswithinadistanceof2D (depthofbeam)or1/4spanfromthefaceofthecolumnarenotallowed The overhangingbarsshouldbeproperlysupported Thecostoftheseworksis deemedtohavebeenincludedintherate
ProvidingandfixinginpositionmildsteelreinforcementofTATA/Vizag/SailSteel ofvariousdiametersforRCC piles,pilecaps,footings,foundations,slabs,beams, columns canopies staircases dowels chajjas lintels pardis copings fins arches etc asperthedetaileddesigns,drawingsandschedulesincludingcutting, welding,bending,hookingthebars,bindingwithGIwiresandconcretecover blocksetc complete Noseparatepaymentforchairs,laps,wastageandbinding wirewillbemade
Sameasitemd1abovebutforProvidingandfixinginpositionhighyieldstrengths deformedbarreinforcementofTATA/Vizag/SailSteelwithyieldstressnotless thanFe415ofvariousdiametersforRCC piles,pilecaps,footings,foundations, slabs beams columns canopies staircases dowels chajjas lintels pardis copings,fins,archesetc asperdetaileddesignanddrawingscheduleincluding cutting,bending,hookingthebarsbindingwith18SWGGIwiresincludingwelding andsupportingasrequiredandprovidingconcretecoverblocksatalllevels includingallleadsandliftsetc complete Noseparatepaymentforchairs,laps, wastageandbindingwirewillbemade
Sameasitemd2above,butforTMTSteelReinforcementofTATA/Vizag/Sail Steel
StainlessSteel304screws nails bolts fasteners etc forallrepairworks
Supplying fabricating erecting aligninginposition fixing StructuralSteel ofTATA /Vizag/SailSteelinalltypesofmembers(Box,Ropes,I-sections,C-sections, L-anglesetc)forColumns,Beams,TrussRafter,Purlinforroofs,lofts,stairs, mezzanines,storageracksforparaffinboxes,portals,braces,underpinning, shoring,frames etc Theratetoincludecutting,anchorfasteners,bolting, welding wastageandapplicationofepoxybasedpaints(Asianmake)asper manufacturer'sspecificationsandasdirected Therateshouldincludepaintingof thesteelasstatediniteme5below METRIC TON
COLUMNS-ISMB250
CIRCULARSTEELHOLLOWCOLUMN-NB200M
Providingfabrications erectingandfixingSS Railing
i)SS PoleMadein16gauge50mm DiameterISapprovedSS304pipewitha ornamentalSSringatthebottomendsSS topatapexforassemblyofupper
Handholdpipewholeunitprovidedwithmirrorfinish (Foraheightof12M)
Note:
Measurementshallbetakenforcompletelaidroofinsquaremeter Overlapswill notbepaidextra Therateshallincludeallthematerial labourbolts nut washers andtoolsandplantsetc complete SteelFramedRoofingSystem
13836 -- kg
ProvidingandfixingofSteelFramedRoofingSystem ExternalSheet:Klippon/ SteellockAZ150SMPcolourcoatedGalvalumein058mmTCTandincluding screwsandclips InternalSheet:Hi-Rib/HispanAZ150BareGalvalume/SMP colourcoatedGalvalumein047mmTCTincludingscrews Insulation:Supply andLayingof50mmthicklogfiberresinbondedfiberglassrollinsulation16kg/m3 densitytobefixedbetweeninternalandexternalsheets SubGirt:G I Purlins40 x50x40mmx16G(16mm)galvanisedsteelfixedtopurlins/girtwithselfdrilling fastenersatmax 500mmcentersandsteelbaseplatesofsizes150x150x6mm
BOXSECTION25x50mm
BOXSECTION100x50mm
Providingandfixingofflashingofallsizesforf1above
ThisitemisworkedoutbytheConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
Providing,supplyingandinstallingcellular(doublewalled)polycarbonatesheet/ tetrapacksheet(dupontorequivalent)/GISHEETroofinginclusive offixingto structuralsteelsupportsystemasperdesignandmanufacturer'sspecification
Thecostshallbeinclusiveofalltaxes Allnecessaryscaffolding craneand accessoryworktobeusedincarryingouttheworksistobeincludedinthecost Thecontractorshallhavetotakeduecareofthesurroundingbuildingandseetoit thatthefacadeskinanditselementsarenotdamagedintheprocessofcarrying outthiswork SQM
G MASONRYWORK
Note:
1)Theitemsgivenbelowshallbeasper MasonryWork ofthespecifications
2)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction
3)CementformanufacturingconcreteblockstobeprovidedbyContractor
4)Onlyselfsupportingscaffoldingwillbeallowed,noholesinmasonrywouldbe permitted
5)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc
6)Factoryincludingblockmakingmachineformanufacturingofconcreteblocks shallbeapprovedby Architect-in-charge
7)Thecementforblockmasonryshallconfirmtotherequirementofminimum cementrequirementforPCC ofconcretespecifications
8)Requiredquantityofconcreteblocksaretobemanufacturedwithgroovesto accommodatetheconduitpipes/waterpipesetc Thegroovesshouldbestaggered onbothsides
9)Therateforconcreteblockmasonrywallsshallbeinclusiveofproducinghalf blocksandoddsizedblockstosuittheconstruction
10)Mortarsforallmasonryworkshallbemixedinanapprovedmortarmixeror concretemixer
11)Handmixingofmortarwillnotbeallowed
12)Onlyriversandand43gradecementshallbeused
13)Washingofsandinrotaryscrewtypewashingmachinesisamust
14)Bricksusedshallbeoffirstclassandshallbeofregularinshapeandtheir edgesshouldbesharpandshallbefreefromcrack Brickshallbefullysoakedin cleanwaterbysubmerginginatankforaperiodof12hoursimmediatelybefore use
15)Contractorwillberesponsibleformakinggoodallthesurfacesofbrick/block masonrywallinitsoriginalformwhereverinchasingthewallisdoneforproviding servicelineslikeelectrical,telecommunicationandwatersupplyandplumbingetc
Providingandlaying
230mmthickbrick(firstclass)masonrywall
in1:6C:M aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins,columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
150mmthickbrick(firstclass)internalmasonrywall
Providingandlaying in 1:6C:M aboveplinthoratalllevelsincludingforoddshapedwalls brickfins columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
100mmthickbrick(firstclass)internalmasonrywall g7* PCC/stonecoping
Providingandlaying in 1:6C:M,aboveplinthoratalllevelsincludingforoddshapedwalls,brickfins, columns,etc includingstrikingjoints,rakingoutjoints,scaffolding,curingetc complete (Min cementcontent15Bag/cum)
Providingandfixing overterraceparapethavingdimensions 330mmwide100mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
Providingandfixing loverterraceparapethavingdimensions 230mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1450mm
b)2300mm
c)950mm
d)1500mm
e)3725mm
ProvidingandfixingRCCLintelsandSilloverterraceparapethavingdimensions 150mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1100mm
b)1450mm
c)1650mm
d)1250mm
e)950mm
f)1500mm
ProvidingandfixingRCCLintelsandSilloverterraceparapethavingdimensions 100mmwide150mm thicknessinpiecesof600mmlengthoveramortar beddingofCM1:6/Limemortar1:3
a)1100mm
b)1450mm
ProvidingandfixingRCCLintelsoverterraceparapethavingdimensions230mm wide230mm thicknessinpiecesof600mmlengthoveramortarbeddingofCM
1:6/Limemortar1:3
a)3725mm
ProvidingandlayingBB cobainallpositionssuchasplinthsandramp
Notes:
1)Theitemsgivenbelowshallbeasper'Plasteringofthespecifications
2)Scaffoldingforplasteringshallbeofselfsupportingtype Holeswillnotbe allowed tobemadeinthemasonryorRCCworkforanchoringthescaffolding
3)OnlyRiverSandshouldbeused Howeverwashingofsandinrotaryscrewtype washingmachinesisamust
4)Mortarforplasteringworkshallbemachinemixedinamortarmixerorconcrete mixer Handmixingofmortarwillnotbeallowed
5)Therateforplasteringshallalsoincludeprovidingandmixing/applyingan approvedbondingagentasperdirectionofArchitect-in-charge andalsoapplying approvedhack-aidonsurfacereceivingplaster
6)Only43gradecementshallbeused
7)Rateshouldbeinclusiveofscaffoldingandcuringshallbestartedassoonas theplasterhashardenedsufficientlynottobedamagedwhenwatered Theplaster shallbekeptwetforatleast10days
Providing12mmthickInternalcementplasterintwocoatsincementmortar1:4 with/withoutneeru,finished smoothforallRCC/brickblockmasonrywork includingcuring andscaffoldingetccomplete
Providingandapplying18mmthickcementplasterincementmortar1:4 without/withneerufinishedsmooth forRCC/brick/blockmasonrycompleteinall respectsincludingscaffolding,bondingagent,curingandasdirectedbyArchitect
Providing&applyingacontinuouscementplasterdripmouldofsize50mmwide and15mmthickunderRCCpardi,chajjaandaroundwindowopeningsatalllevels includingnecessaryscaffolding,stagingetc andcuringcomplete
Notes:
1)Theitemsgivenbelowshallbeasper'Paintingofthespecifications
2)ScaffoldingforPaintingshallbeofselfsupportingtype Holeswillnotbe allowed,tobemadeinthemasonryorRCCworkforanchoringthescaffolding
3)ThebrandsofthePaintshallbespecifiedandreadymadepaintofrequired shadeshouldbeused
4)Thesurfaceshallbemadeperfectlysmoothbyrubbingwithsandpaperof differentgrades
5)Allholesandopenjointsshouldbefilledwithstrongputtyorwithamixtureof glueandplasterofparisandsmoothenedbyrubbingwithsandpaper
6)Insteelwork,allscales,dirt,suppliersdeliverymark,oil,greaseetcshallbe removedwithsandpaperbeforepainting Specialcareshallbetakenforcleaning thecorners
7)Eachcoatsshallbeallowedtodryupperfectlybeforethesucceedingcoatis laidoverit
8)Rateshouldbeinclusiveofscaffolding,curingandalsodewatering&keeping surfacedryduringconstruction
Providingandapplying3coatsoveracoatofprimer,ofoilbounddistemperof approvedshadeandofapprovedmakeoverconcrete/plasteredsurfaces includingpreparingofthesurfaces,scaffoldingetc completeinallrespects
Providingandapplyingacrylicemulsionpaintofapprovedquality,finish,colourand shadetooldandnewsurfacesinthreecoatsincludingpreparingthesurfaces applyingprimer,putty,etc complete
Notes:
1)Theitemsgivenbelowshallbeasper'Flooring'ofthespecifications
2)Atleast6samplesforallfinishingitemsofwork,fromdifferentapproved sourcesshallbesubmittedbeforestartingtheworkforapproval Architectin chargedecisionregardingtheshade,qualityandthesourceisfinal Alllike materialsofflooring cladding etctobefromsamebatchasperapprovedsample
3)Rateshallbeinclusiveofallexposedstone/tileedgestobechamfered,hand polishedandmouldedasdirected
4)Ratesforverticalcladdinginstoneofthicknessfrom6mmto25mmshallinclude exposedrightangularcornerjointsfinishedandedgespolishedandmouldedas perArchitect'sinstruction withcutting6mmgroovesandalsoedgepreparationto suitcornerangles
5)Skirting/dado/cladding,becauseofvaryingheightwillbemeasuredandpaidon squaremetrebasisinsteadofonrunningmetrebasis
6)Therateforflooring/claddingshouldbeinclusiveofbedding/backcoatas specified Thethicknessofmortarbeddingorbackcoatspecifiedisminimum Thisthicknesswillvaryaccordingtothethicknessofflooringorcladdingmaterial soastosuitthespecifiedlevelorline TheContractorshallberesponsiblefor properbondingbetweenbackingcoat&masonryworkorRCCworkandhisrate shallbeinclusiveofprovidingandapplyingapprovedbondingagent
7)Forallverticalcladding,anapprovedchemicaladhesivefortilesasper manufacturer'sinstructionsshallbeusedandtheratesquotedshallbeinclusiveof thecostofthisadhesive,forathickness3mmto4mm
8)Unlessotherwisespecified,allsizestobeinmetricsystem
9)Scaffoldingforexternalcladdingshallbeofselfsupportingtype Holeswillnot beallowedtobemadeinthemasonryorRCCworkforanchoringthescaffolding
10)Therateforverticalcladdingshouldalsoincludetheworkonisolatedcolumns chamfers,etc
11)Noseparatepaymentwillbemadeforprovidingandfixing,oddsizedtilesof anyshapeandsizetosuitconsultantrequirement
12)White/ColouredcementwithmatchingpigmentsorJohnsonBALgroutwith appropriatecolourshallbeprovidedbyContractorathiscost
13)TheContractorshallprovidesuitablesupportsforsupportingthecladdingtiles andremoveitonlyafterthetileshavefirmlyadheredtoitslocation
14)Edgesofcladdingtilesfixedonthecornersofthecolumnsandwallsshouldbe polishedasperdirectiveofArchitect,orasindicatedinthedrawings
15)Themaximumthicknessofthepastepreparedbyusingtileadhesiveand appliedonthewallandcolumnsurfacesshouldnotbemorethan3mm Contractorshallhavenoextraclaimsonaccountofincreaseinthethicknessofthe pastebeyondmaximumthicknessasspecifiedaboveduetofaultyworkmanshipor anyotherreason
16)Mortarrequiredforbedding/backcoatshallbemixedmechanicallyinmortar mill Onlyriversandshallbeusedinthemortar
17)Allfixtures,electricalpoints,lightsetctobealightedwithtiling,groovesand pattern flushwiththewallfaceasperdetailsanddrawings Amockupforthe sameshallbegotapprovedfromArchitect
18)Thecontractorsarerequiredtostudydrawingscarefullytounderstandfixing detailsofflooring,skirting,claddingetc,tokeeprequiredgroovesbetweendifferent finishesatdoorandwindowlocationsflooringandskirtingjunction,wallandceiling junctionetctomatchflushlinei e verticalplaneofwallandskirtingetc
19)Rateshallbeinclusiveofcostofscaffolding,grouting,curing,finalpolishingby non-slipwaxpolishandcleaningofsurfacesandalsodewatering&keeping surfacedryduringconstruction
20)Asample/mockupofflooring,cladding,etctobegotapprovedfrom,Architect
21)Alladditionalgroovestobeprovidedinvertical,horizontalanddirectionas shownindetaileddrawingsorasdirected
22)Tomakewallcladdingsurfaceandskirtingsurfaceflush wallatskirtinglevel shallberequiredtorecessinsideasperfixingdetails Thenecessaryrecessesin RCCwalletcshallbetakenatthetimeofconstructionitself
23)Only43gradecementshallbeused
Providingandlaying15-32mmthickhandcutandmirrormachinepolishedgreen squareorrectangularrangingfrom200mmx200mmupto 600mmx600mmfinishedsizeandofapprovedcolourandshadeinsmaller patchesforrepairorinlargerareasincluding20mmthick1:2limemortarbedding or1:6cementmortarbedding,tobecompactedproperlybysuitablemethodas approvedbytheArchitect,beforelayingKotahstoneinposition Jointsfinished withneatcementslurry widthofjointshallbebetween10mmto150mmlayingas perdesign,including3coatsofmachinepolishingafterlaying,curing,cleaning completeasdirected
Sameasitemk2abovebutforrisersandtreadswithmouldingfornosing,antiskid groovesetc complete
-Do-sameasinitemNo ofheightbetween 100mmto2000mm,mirrorpolishedandmachinecut15mmthickkotahstone,and sizetomatchthejointsinflooring,etccomplete
Providingandlaying25-32mmthickhandcutandmirrormachinepolished
squareorrectangularrangingfrom200mmx200mmupto 600mmx600mmfinishedsizeandofapprovedcolourandshadeinsmaller patchesforrepairorinlargerareasincluding20mmthick1:2limemortarbedding or1:6cementmortarbedding,tobecompactedproperlybysuitablemethodas approvedbytheArchitect beforelayingKotahstoneinposition Jointsfinished withneatcementslurry,widthofjointshallbebetween10mmto150mmlayingas perdesign,including3coatsofmachinepolishingafterlaying,curing,cleaning completeasdirected
Sameasitemk6abovebutforrisersandtreadswithmouldingfornosing,antiskid groovesetc complete
ProvidingandfixingWhite/ceramicantiskidtiles{Kajaria,Johnson,somanyor approvedequivalent}200x200mmto400x400mminsizeandminimum6mm thickfordadooftoiletsinrequiredpositionlaidonabedof1:4cementmortar plasterof15mmthicknessincludingneatcementbacking,fillingjointswithwhite cementslurry,curingandcleaningcomplete (BasepriceoftileRs400/Sqm)
Providingandfixingwhiteceramictiles( ){Kajaria Johnson somanyor approvedequivalent}200x200mmto400x400mminsizeandminimum6mm thickfordadooftoiletsinrequiredpositionlaidonabedof1:4cementmortar plasterof15mmthicknessincludingneatcementbacking,fillingjointswithwhite cementslurry,curingandcleaningcomplete (BasepriceoftileRs500/sqm)
Providingandlayingfullbody8mmthick ofRestile/ Pedder/Johnson/Nitcooranyapprovedmakecolourorofsize150x150/200x 200/300x300/400x400/600x600/900x900mminclusiveofbeddingof CM 1:4,forlocalisedrepairsorinlargequantities,forflooring/skirting/dado, andwithcementfloatandJohnsonbalgrout
-Do-sameasinitemNok9abovebutforskirting/dadoofheightbetween100mm to2000mm,mirrorpolishedandmachinecut15mmceramicvitrifiestiles,andsize tomatchthejointsinflooring etccomplete
Providingandlayinginrequiredpositionchinamosaicflooringoverconventional waterproofingtreatmentoratgroundleveloverPCCorIPSbaseofapproved colourandpatternon40mmthickbeddingof1:4cementmortarincludingneat cementfloat,givingproperslopes,compaction,curingetc complete
Sameasabovebutforwashbasincounters
Notes:
1)CarpentryandJoinery,Timber,Steelcasement,AluminumDoorsWindows, skylightsopenable slidingwindows rollingshuttersandpolycarbonatesheet curtainwalls,etc
2)Forallaluminumworks thecontractorshallsubmitshopdrawingforeachitem ofworkindicatingthesectionofaluminum,itsweightandjoinerydetailandtotal weightofwindow/door/partitionwallsetc Whereverpossiblerivetingshallbe resortedtoforconnection Alternativelyhotdippedgalvanizedpinheadedsheet metal/brass screwscouldbeused Nomildsteelwithouthotdippedgalvanizing shallbeusedforanyfastenings,etc
3)TheratesshallnotbepaidseparatelyforAluminumsectionsusedonweight basis
4) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials neoprenerubbergaskets screws,etc
5)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
6)Alljointsbetweencivilworkandaluminumframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
7)Ratesforrepairsaswellasprovidingandfixingofnewdoors windows sky light,rollingshutters,etc inthissectionshallbeinclusiveofalltheitemsof hardware/fittingsandnoextrashallbepaidtothecontractortowardsthecostof hardware/fittings
SQMT
8)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:
9)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)
10)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand
11)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)
12)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized
13)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete
14)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor 'DORMA'TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect
15)BrassoxidizedBabylatches,75mmlongwith25mmx8mmthickboltcomplete withknob Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal
16)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release
17)PlainMorticelocks6leversLatchBoltofGodrejmakeequivalentwithbrass bodyandchromeplatedflatplatetoedgeofdoorincludingfixingtotimberor aluminiumshutterframesetccomplete
18)Sameasaboveitem(16)butwithdeadlock
19) 3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)
20) Doorbufferwithrubber/PVCbushshutterorwallmounted
21)Providingandfixing andrepairrateswillalsobeinclusivealdrops,handles stopperetc allcomplete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timberdoubleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc complete
Timbersingleleafhingeddoor
Providingandfixing1stclassteakwooddoorframes(BTC)ofallsizesincluding makingsingleordoublerebatesforshuttersasperdrawing,6FischerUniversal FramefixingFUR10x135T/FUR10x150Torequivalentfastenerinsteadof holdfastforfixingframestoconcretemembersormasonrywallsapplying solignumontimbersurfaceincontactwithmasonry/concreteandDucoPaintor polishofapprovedcolourandmake,includingmouldedarchitraveetc
Glassdoubleleafpivotdoor
Providingfabricatingandfixinginpositionaluminiumframecomprisingofopenable opaqueglassshutter(lockinghandlesandpullhandlesforshutter,withfloor springforrotation)includingmaskingofjamsbeforecompletionofworkdemasking
Providingfabricatingandfixinginposition2trackcolouranodisedextruded aluminumsectionsofJindalorequivalentapprovedmakeforslidingwindows, openablecomprisingofouterframe(035kg/rm) shutterframe(050kg/Rm) glassshutter--(040kg/Rm),mullionforouterframe(055kg/Rm),locking handlesandpullhandleforeachshutter,onepairSS frictionhingesforeach shutterand5mmthickclearfloatglassModiorwiredglassorequivalent with neoprene/rubbergasketwithhinges lockingarrangementandwooden encasementwherevernecessaryincludingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan
AluminiumOpenableLouveredWindow
Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium heavysectionsJindalorequivalentmakeforlouveredwindows,openable comprisingofouterframe(035kg/rm),louveres(050kg/Rm),mullionforouter frame(055kg/Rm),rotatingknob,includingmaskingofwindowsillsbefore completionofwork,demaskingaftercompletion,cleaning,ratetoincludecolour anodisingallaluminiumsectionstoathicknessofanodicfilmnotlessthan
Providingfabricatingandfixinginpositioncolouranodisedextrudedaluminium sectionsofJindalorequivalentapprovedmakeforfixedwindowsFixedglass
Notes:
1)Thecontractorwillgivea10yearsguaranteeoftheworkundertakenon Rs100/-Stamppaperontheapprovedformatdulyregistered
2)Tenpercentamountofvalueofworkswillberetainedfortheperiodoffiveyears fromthedateofactualcompletionofthework,willbereleasedprogressivelyat fourpercentaftertwoyearssubjecttoattendinganyrectificationofdefectsand balanceamountsbytheendoffiveyears
3)Allworktobedonethroughspecialistwaterproofingandstructuralrepair agenciesshallbeundertakenonlyontheapprovaloftheArchitect
Providingandapplying70mmto75mmthickproprietarybrandcementbased waterproofing(boxtype)forbottomRCCraftslabandsidesofRCCwallsofwater tanks,septictanks,effluenttreatmenttanks,etc including providingleakproof treatmentby injectiongrouting toconcretemembersat10mcentresinboth directionsandalsoatallconstructionjoints andprovidingandfixing20mmto 25mmthickroughShahabadstoneorotherapprovedstonetilessetin20mmthick 1:3waterproofcementmortarandfinishingthebylaying/plastering,with20-30 mmthickC:Min1:3withwaterproofcompound(Contractortogivecomplete specificationsforwaterproofingsystemheproposetocarryout)
ProvidingandlayingwaterproofinginWCandbathroomincluding inall positionconsistingofspecialisedapprovedwaterproofingcompoundandmaterial asperspecificationswithallleadandlift
Providingandlayingcementbasedwaterproofingtreatmenttoterracewithbricks batslaidinrequiredslopetodrainthewaterforanyspanaftercleaningthe base surfaceapplyingacoat ofcementslurryadmixedwithapprovedwaterproofing compoundandlayingthebrickbatsonbottomlayerinC:M1:5admixedwith approvedwaterproofingcompoundfillinguptohalfdepthofthebrickbats,curing thislayerfor3daysapplyingcementslurryoverthislayerjointingofbrickbatswith C:M1:3admixedwithapproved waterproofcompoundandfinallytopfinishingwith average20mmthicklayersofcementmortaraddedwithjutefiberat1kgperbag includingfinishingthesurfacesmoothwithcementslurryadmixedwithapproved waterproofingcompound
Thefinishedsurfaceshallbelinedwithfalsesquaresof300mmx300mmor preparingthesurfacetoreceivewhitechinamosaicflooringonit(costtoinclude whitechinamosaicflooring)andmakingthejunctionsattheparapetroundedand taperedtowardstopforrequiredheight withdripmouldatthejunctionofthe plasterandparapetincludingcuringbypondingtestetc complete Average thicknessofbrickbat200mm
WaterProofingChajja
Providingandapplyingwaterproofingtreatmentoverchajjausingproprietary cementbasedsystemlikeIndiaWaterproofingusingbrickbatsof50mmormetal no2 averagethicknessoftreatment50mm finishedwithsmoothcementfinish withfalsetilemarks,includingbreaking/removingexistingwaterproofingand cartingawaythedebrisetc complete
Tilejointfilling
Providingandfillingcementbasedtilejointsealingcompound(JohnsonBalGrout orequivalent)inbath/WC/toilet/flooringtilesincludingrakingoutoldloose jointingmaterial,curingetc complete
SQM
SQM
SQM
Providingandfillinggapsbelowdoorframes,aroundNahanitrapswith Roffe-grout-GPorequivalentincludingcleaningthesurfaceofallloosematerials curing mixingaspermanufacturer'sinstructionsetc complete
ProvidingandfixingLeadFlashing600/900mmoverChajjashallbehoused approximately300mmabovechajjainamortarjointofadjoiningmasonrywall,this sheetctshallbeslopingoutwards Fasteningdown –Thesheets,shallbe fastenedwiththebestSSorBrassscrews/boltsandleadwashersAllen’s Fisher orotherapprovedfasteningsasdirectedbytheConservationArchitect Thelead sheetingshallbegoodmilledleadnotlessthan10Kg/Sqmbenttotheshape fastenedintothewall groove20mm,withbrass/sswallhookswithjointsatright anglestotheflowbyadripwithaproperlap iflevelspermit orby75mmjointsof foldedlead
SECTION-III: CARPENTRYANDBUILTINFURNITURE
Notes:
1)CarpentryandJoinery,forpartitions,tables,cupboards,storageunits,desks, labfurniture,museumdisplayfurniture,officefurniture,auditoriumandlecture theatrefurniture doors windows skylights falseceilingetc
2)Forallcarpentryandfurnitureworks,thecontractorshallsubmitshopdrawing foreachitemofworkindicatingthesectionofwoodits joinerydetailetc Whereverpossiblewoodenpinsshallberesortedtoforconnection Alternatively stainlesssteel/brass,screwscouldbeused Noothernails/screwsshallbeused foranyfastenings,etc
3) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc
4)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturer'sforapproval Architectdecisionshallbefinal
5)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
6)Ratesforrepairsaswellasprovidingandfixingofnewcarpentryitemsand furnitureinthissectionshallbeinclusiveofalltheitemsofhardwareandfittings requiredandnoextrashallbepaidtothecontractortowardsthecostofhardware/ fittings
7)AllHardwareshouldbeaspersamplesapprovedbyArchitect Providingand fixingfollowinghardwareitemsinoxidizedbrass(unlessotherwisestated) including,fixingwithappropriatescrewsandfastenersinbrass/stainlesssteel metalscrews(Nettlefoldorequivalent)whereverspecifiedetcofapprovedmake typeandthickness:
8)Providingandfixingthehardwarecompleteinallrespectswithnecessarypins, plates,screwsetc(Allfittings&fixturesshallbeofHeavydutybrassoffirstquality)
9)Allhardwareandhingesshallbeofpalladiumorapprovedequivalentbrand,all otherhardwareshallbeofDormaorapprovedequivalentbrand
10)Hinges:Railwaytypeheavydutyhingesinbrassoxidizedwithstainlesssteel pinsofdiameternotlessthan4mmandleafthicknessnotlessthan4mm(125mm x65mmx4mmto300mmx65mmx4mm)
11)Hinges:Parliamentarytypeheavydutyhinges5mmthickbrassoxidized
12)Towerboltshavingboltdiaof10mminbrassoxidized,inbrassbody600mm longetccomplete
13)Doorhandles 'Dorma'TGDI35025Spullhandle,25mmdia,350mmlongor DORMA TG9155ormatchingwithexistinghandleasspecifiedandapprovedby theArchitect
14)BrassoxidizedBabylatches,75mmlongwith25mmx8mmthickboltcomplete withknob Vacant/Engagedetcasperapprovedsamples Brassaldropsshall matchexistingoriginalaldropsinthebuildingandshallbereusedorfabricatedto matchtheoriginal
15)ConcealedtypehydraulicdoorcloseroropendoorcloserofDormaor equivalentbrandwithDormadoorstopper,springloadedwithrubberbushandfoot release
16)PlainMorticelocks6leversLatchBoltofDorma/Godrejorapproved equivalentmakeequivalentwithbrassbodyandchromeplatedflatplatetoedgeof doorincludingfixingtotimberoraluminiumshutterframesetccomplete
17)Sameasaboveitem(16)butwithdeadlock
18)3mmthickSSkick/pushplatefixedwithSSscrewsof150-400mmdepth (CP brassdomicalhead)
19)Doorbufferwithrubber/PVCbushshutterorwallmounted
20)Providingandfixing andrepairrateswillalsobeinclusiveofaldrops,handles stopperetc allcomplete
PartitionWalls
Providingandfixingfullheight50mmthickHPLpartitionwallsofheight2100mm includingallfixing
Providingandconstructinginbuiltmasonryandroughkotahseatsasshownin architecturaldrawingsalongwithacladdingofBluecolourterrazzo(make:Bharat FlooringsandTilesPvt Ltd -Premiumterrazzoseriesorequivalent) laidona bedof1:4cementmortarincludingneatcementbacking,fillingjointsandwhite /colouredcementslurry,curingandcleaningcomplete
StainlessSteelBenches
ProvidingandfixingperforatedSSsheet(SS304)benchofapproveddesignwith SSpipeframingand3mmthickperforatedSSsheetpanelsasshowninthe architecturaldrawingswithnecessarybolting/weldingandfixingontilesurface withanchorfastenerbolts etc complete
Steelamphitheatre
Providingandfixingwithallthebaseplatesandnecessaryjoineries,finishing STEELBOXSECTION50x50mm metricton WOODENPLANKS(100MMWIDEAND20MMTHICK) SQM
SECTION-IV: MISC
Notes:
1)Rateshallincludeminorcivilwork,scaffolding,electricalworks,dismantling, liasoningcost,steelitems,etc
2)Thequotedpriceshallbeinclusiveofcentralexciseduty,VAT,octroiandservice taxandallotherapplicabletaxes Thisquotationshallnotbesubjecttoprice variationcost
3)Thecontractorshallmakenecessaryarrangementstoprovidesuitablelockable weatherproofstoragespaceforthematerialsandshallalsostacktheexisting dismantledmaterialinasafesecureplaceforthedisposalofthemunicipal authorities
4)Thecontractorshallincludeinthequotation60monthsfreemaintenance,which willbecommencedfromthedateofcompletionofproject
5)Thecostshallbeinclusiveofallpreparatoryworkandnoextracostwillbe providedtowardsthisitem
7) Therateshallbeinclusiveofproviding&fixingglasspanelsincludescostofall typesoffixturesandfasteningsmadeofanymaterials,neoprenerubbergaskets, screws,etc
6)Forallworksinthissectionasspecifiedbytheconservationarchitect,the contractorshallsubmitshopdrawingforeachitemofworkindicatingthesections materials,its joinerydetailetc Whereverpossiblewoodenpinsshallberesorted toforconnection Alternativelystainlesssteel/brass,screws/boltscouldbeused Noothernails/screwsshallbeusedforanyfastenings,etc
8)Contractorshallsubmitsamplesofassemblysectionsfromdifferent manufacturersforapproval Architectdecisionshallbefinal
9)Alljointsbetweencivilworkandtimberframesshallbesealedandmadeair tightbyapplyingSiliconesealantorequivalentasapprovedatContractor'scost
FabricationandinstallationofInformationSignasspecifiedinthedrawings Providing&fixinginposition inaluminiumextrudedbrown anodizedsectionwithlettersinvinylonbothsidescoveredwithacrylicsheetand asperapprovedsamplebyArchitectfixingasdirected
FabricationandinstallationofTreeGratingasspecifiedinthedrawings
i)Castirontreegrating,paintedwithanticorrosionprimerand2coatsof polyurethane/epoxypaintinapprovedshade,tobefixedontoconcretebaseas shownindrawings Ratetobeinclusiveofbasegrouting,providing,fixing,nuts, bolts,welding,painting,etc complete
ii)GraniteStonecobblestoneedgingaroundthetreebase,withwhiteround pebbles/withgravelbedinsideasindicated
SECTION-V: ELECTRICAL
ThisitemisworkedoutbytheElectricalConsultant
Forthepurposeofthiscourseanapproximateamountisbudgeted
Supply,Installation,TestingandCommissioningofEarthingstationasperIS3043 consistingof40mmGI3000mmlongpipe suppliedwithfunnelattopincluding saltcharcoal,masonrychamber,testlinkbox,hardwareincludingexcavationand masonryworkwithcastironcoverforthechamber
Supply&Layingof followingsizesofstrips &wiresfromearthingchamber/Gridto theelectricalequipment&terminatingthesame Theportionofthestripunder groundshallbelaidatadepthof600mmandonsurfaceshallbefixedwith spacers&clamps&alsoonTray Excavation&allcivilworktobeincluded 25mmx3mmGI stripforDistributionBoard(FirstDistributionBoardinacluster ofDistributionBoards)
8SWGGI EarthingwireforLighting&PowerDistributionBoard
Supply,Installation,testing andcommissioningof3phaseenergymetersuitable forunbalanceloadandincludingnecessarycutoutandjumperwiresetccomplete aspersupplycompany'srequirement
100
Supply,Installation,testing andcommissioningofTPNMCB16A andincluding ncessarycutoutandjumperwiresetccompleteaspersupplycompany's requirement
Supply Installation testing andcommissioningofTPNMCB40A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompanys requirement
Supply,Installation,testing andcommissioningofTPNMCB32A andincluding necessarycutoutandjumperwiresetccompleteaspersupplycompanys requirement
Supply&InstallationofstandardmanufacturersDistributionBoardforLighting It shallbeastandardBoardwithdoubledoor&suitableforrecess mounting&shall beasfollows Scopeincludesmountingarrangementincludingnecessarysteel, hardwareetcWiresinDB tobeproperlydressedwithbuttontapeandwithlugs labelsetc
Incomer40ATPNMCB-1No 40A,30mA,2P,RCBO-3NosOutgoing 6/10ASP MCB-24Nos
Supply,Installation,Testing&CommissioningofPVCArmouredCablefixedto walls,Ceilingswithclamps,spacerssaddlesorlaidinreadymadetrenchortiedto cablestraywithcableties,tagsetc asfollows 1100VgradeasperIS
Installation Testing&Commissioningofcables(onwalls trays) PVCinsulated 1100Vgrade,steelarmoredasperIS1554withlatestamendmentincluding spacers,saddles,tags, etcThecablesto beproperlydressed
4Cx16SqmmALAYFY
3Cx10SqmmALAYFY
4Cx10SqmmAYFY
3Cx4SqmmAYFY
3Cx6SqmmAYFY
3Cx25SqmmAYFY
TerminationofcableswithHeavydutySiemenstypeglands&lugs Lugsused shouldbeCopperforcoppercables&Aluminiumforaluminiumcable Scopeto includeallmaterial&labourincludingpropertools Insulationtape
4Cx16SqmmALAYFY
3Cx10SqmmALAYFY
4Cx10SqmmAYFY
3Cx4SqmmAYFY
3Cx6SqmmAYFY
3Cx25SqmmAYFY
Pointwiringforlight,bellpoint ScopetoincludecircuitWiringforlighting&the lightswitchboardwithswitches&furtherwiringtolightpoints Theswitchboard shallberecessmounted/surfacemountedofGIstandardasperthesupplier The pointWiringshallconsistof3x15Sq mmcopperwire,PVCinsulated,1100V gradeinPVCconduit/PVCcasingcaping Thewires&conduitsshallrunfromthe switchboardtotheindividualpoint&circuitwiringshallbeof3x25mm2copper wirefromdistributionboardtothe switchboard Modularplatetypeswitchestobe used6ASwitchSocketonswitchboardtobeincludedInmajorityofthecasesthe lightsaregroupswitchedfromtheDistributionBoardinwhichcasethewireshall be3x25mm2 AllwiresshallbeFRLS
PrimaryLightPointwiringofaveragelengthupto5meterslengthofwire
PrimaryLightPointwiringofaveragelengthupto55to10meterslengthofwire
PrimaryLightPointwiringofaveragelengthupto105to15meterslengthofwire;
PrimaryLightPointwiringofaveragelengthupto155to20meterslengthofwire;
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto5metersof lengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto55to10 metersoflengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto105to15 metersoflengthofwire3x15sq mmwires
SECONDARYLIGHTPOINT(FirstLighttosecondlightpointUpto155to20 metersoflengthofwire3x15sq mmwires
FanpointwiringshallbesameasPrimarylightpointpointwithindividual controlWireofsize3x15sq mmsizeshallrunfromtheswitchboardtothefan pointthroughPVCconduit/PVCcasingcaping ThecircuitfromtheDBtothe switchboardshallbe3x25sq mmwiresSpaceforregulatortobeprovidedinthe switchboard Upto5Metersof lengthofwire
FanPointwiringwiringlength55to10meterlength
FanPointwiringwiringlength105to15meterlength
FanPointwiringwiringlength155to20meterlength
Exhaustfan/WallFanpointswiringshallbesameasPrimarylightpointwith individualcontrol&6Asocket&top@thefanpoint Wireofsize3x15mm2size shallrunfromtheSwitchBoardtothefanpointthroughconduit Thecircuitfrom theDB totheSwitchBoard with3x25mm2wire
Pointwiringfor6Ampswitchsocketpoint Scopetoincluderunningof3x25mm2 copperwire,PVCinsulated,1100VgradeinPVCconduit Wirestoberunfromthe PowerDistributionboardtotheIndividualsocketsupto4socketscanbeloopedon onecircuitWorkstationRawpowerAllwiresshallbeFRLSWiringlengthupto5 meters
6Asocketpointwiringlength55to10meters
6Asocketpointwiringlength105to15meters
6Asocketpointwiringlength155to20meters
Pointwiringfor6/16Amp switchsocketpoint ScopetoincludecircuitfromDB toindividualpoints Conduit,accessories&wireswith3x4mm2copperwiretobe laidfromDBtoindividualsocket TwosocketpercircuittobeconsideredAllwires shallbeFRLSWiringlengthupto5meters
6/16APointwiring55to10meterlengthofwire
6/16APointwiring105to15meterlengthofwire
6/16APointwiring155to20meterlengthofwire
6/16APointwiring205to25meterlengthofwire
Supply,Installation,Testing&Commissioning6Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections
Supply,Installation,Testing&Commissioning6/16Aswitchsocketoutlet&box consistingofModularplatetypeswitchesincludingconnections
Supply,Installation,Testing&Commissioningof20AReyrollPlugsocketwith3pin MetalTop,inmetalboardwith20ASPMCB
Supply,Installation,Testing&Commissioningof225mmDia ExhaustFanwith connection
Providingandinstalling connectingandcommissioning32ATPNSFUwithHRC Fuse
ProvidingandlayingTwopairTelephonecableinexistingconduit/casingcaping
Providingandinstallingoutlet fortelephonecable
Providingandinstallingcelingfan1200mmsweepwithfivestepselectronic regulator
Supply&InstallationoflightfixtureswithSigmaBallastincludinglamps,junction boxes,downrod/supports,hardwares rawlplugs,wires/cablesetc asrequired andconnectingittoswitchboards
SupplyandInstallationofPortableEmergencyLightonBatterysuitableforupto10 hours Installite/Canaramake Mountingarrangementforlamptobeincluded
1x18WBracketlight
WST71150withGI waterpipearm1mlongweldedtothecap
WFZ42250
WIF22228SGW
Liasoningchargeswithrespectiveauthoritiesforshiftingofpointofelectrical serviceandothers
Excavationinoutsidesoilincludingrefilling
Supplyinganderectingsteeltubulerpole1651x1397x1143mmthickwith 45x45x365mmthickand(56x27x27mm)respectively11mtrs LongasperIS 2713withtestcertificatefrommanufacturercompleteerecteddulypaintedwithtwo paintsofredoxideandtwocoatsofaluminiumpaintcompleteerectedinposition withMS baseplateof30x30x06cmsthickweldedatthebottomandsuitable polecaperactedwithsetscrewsorwieldedcompleteerectedCC foundationand plinthJunction/Loopingboxincluded
Note:Foritemnos 16,17and18,ratesshouldbeinclusiveofa
Supplyinganderectingcentrifugalwaterpump(Monoblock)withCI impler, primingfunelcockandcommonflangemountedonacommonshaftofinduction motorof400V3phaseAC supplyofminimum3H PMotorcapableof dischargingwater600to170litesperminutesat125to275meterstotalhead fromallclauseswithfoundationandwith50mmsuctionand50mmdelivery,water pumpshallbeconfirmingtoIS1520complete(Crompton/Kirloskar/Grundfosor anyotherequivalentmake)
Waterlevelcontrollerwithnecessaryprobesforcontrollingmotorforcutoffwhen uppertankwaterlevelisfull,whenwaterlevelinthetankcomestopredetermined levelpumpshallstartautomatically When waterlevelinthesuctiontankisbelow thewaterlevel,thepumpshouldnotstart Alsopumpshouldnotrundry The controllershallhavemanual autoswitchesandselectionofpump Therateshall includenecessarywiringwithcopperwires
DOLStartersuitablefor3HPmotorincludingoverload
Providingandfixing25mmPVCconduits/Casingcapingincludingallfittings
Note: Allcataloguenos referredinvariousitemsofsanitaryfittingsareasperBelmonte /Hindustan/ParrywareSanitarywareCataloguesandallfixturesareJaguar Continentalseries
Providingandfixingapproved'Indian make white/colouredglazedvitreous chinawarefloormountedEuropeanwaterclosetcisternincluding- Nos
a)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock CPbrass flushbendetc
b)CIchairsupportsforthewatercloset
c)Whiteorcoloured solidplasticseat&cover veryheavyqualitywith rubber buffersfixedtotheclosetwithCPbrasspillarhinges
100mmdiaconnectorpipefromPtraptothejunctionofthesoilstackonexternal faceofbuilding Nos
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazed'vitreous chinawarewash'handbasincountertoporsuitableformountingbelow'counter comprising: Nos
a)White/colouredglazedvitreouschinawareovalshapedwashbasin,size 570mmx425mmwithsupportingMSorCIbrackets
b)1No15mmCPbrasspillarcockwithallfittings
c)1No32mmCPcastbrassbottletrapwithextensionpiecetowall,wallflange withrubberadopterwasteconnection
d)1NoheavyqualityCPbrassangularstopcock15mmsizewithCPbrassflexible connectorpipe Thesupportingbracketshallbeprovidedwith3coatsofapproved paintofapprovedshade
Providingandfixingvitreouswhite/colourchinawareurinalcomprising Nos
a)Largeflatbackwallhungurinalsize250x330x460mm
b)flushingtankof10ltrssupplyingto3urinalswithallfittings
c)CPbrasschromiumplatedflushpipingfromflushvalvetourinalterminatedwith a15mmscrewedspreader
d)32mmdomeCPcastbrasswaste
e)32mmnbCPcastrunningtrapwithextensionpipetowall,wallflange,rubber adopterforwasteconnection
Providingandfixing15mmsizeCPbrassbibtapISImarkedheavyqualityonGI lineswithflangeandCPconnectorofapprovedmake Nos
Recessedtypewhite/colouredtoiletpaperrollholdersize150mmx130mmin vitreouschinawarewithwoodenrodandspringincludingcuttingrecessinwall settingtherollholderincementsandmortar1:3reinstatementofwallsurfaceto originalconditionsetc complete Nos
ProvidingandfixingapprovedheavyISImarkedmakeCPbrass spoutsforbath with20mmthreadsoutsideand15mmthreadinsidecompletewithtaperedwall flange Nos Size15mm
ProvidingandfixingapprovedISImarkedmakeheavyqualityeasycleanvariety screwdownCPbrassstopcocksonGIlines,withfemalethreadedends Nos Size15mm
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareOrissawaterclosetcomprising: Nos
a)Orissapansize580mmx440mmwithboxriminletwithPtrapasrequired
b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
ProvidingandfixingapprovedISImarkedmakewhite/colouredglazedvitreous chinawareindowesternwaterclosetcomprising: Nos
a)Indowesternfloormountedsize600mmx460mmwithboxriminletwithPtrap asrequired
b)10litrescapacityflushingcisternwith15mminletconnectionwithCPbrassstop cock,CPbrass flushbendetc
100diaCI connectorpipefromPorStraptothejunctionofsoilstackonexternal faceofbuilding Nos
Providingandfixinggraniteurinalpartitionssize750x1200fixedtowallwithCP brassbolts,nuts&expandableanchorfasteners Nos
ProvidingandfixingISImarkedmakeSSsinkwithintegraldrainboard,single pressingofsize500mmx450mmwithsupportingbracketsCPbrasswaste bottle trapetc complete Nos
SupplyandfixingHindustanPilkingtonmakemirrors 6mmthickwithplainor bevelededge,8mmthickplywoodbacking,4NosCPbrassscrewswithCPbrass capsscrewedtorawlplugsembeddedinwall Nos
Supplyandfixing40mmCPbrasswastecouplingwithrubberplugandCPchain Nos
Providing&fixinginpositionheavytestedscrewdown15mmCPbrasssinkcock withraisedJshapedswingingspoutwithflangeofapprovedmake Nos
ThisitemisworkedoutbytheServicesConsultant Forthepurposeofthiscourseanapproximateamountisbudgeted
Providing,laying,fixingjointingwithscrewedjointsusingteflontapeGIpipes heavyqualityconformingtoIS1239includingallfittingssuchassockets,unions reducers,longorshortbends,elbows,nipples,flanges,checknuts,clampsetc testingthepipesandspecialsandpaintingthepipesandfittingswithonecoatof approvedprimer&finishingcoatsallasperspecificationsForpipesinexposed conditions:
Providing,laying,fixingjointingwithscrewedjoints'C'classheavyGIpipes conformingtoIS1239includingallfittings testing paintingwithbitumasticpaint protectionwrappingwithHessienfacedpolyethylenetaping&paintingcompleteas perspecifications Forpipelineslaidbelowgroundlevelandlaidinchasesin walls Therateincludesexcavationandcuttingchasesinwallsandreinstatement)
Providing,fixingandtestingheavyqualitygunmetalorbrassballvalvewith screwedends20kgmclassonGIorcopperpipelines(Leader/ZOLOTOmake)
ProvidingandfixinginpositiontestedheavyqualityISImarkedfullwaygunmetal gatevalveofneworequivalentmakehavingbothendsscrewedfemale conformingtoIS778:1984etc complete
i)50mmdia
ii)40mmdia
iii)32mmdia
iv)25mmdia
v)20mmdia
vi)15mmdia
Providing erecting fixingandcommissioningPVCoverheadwatertank(BMC approved)includingmakingofproperplatformasperconsultant'sdirection,lifting oftanktoterracefloorlevel,placingoftankonplatforminproperalignment, makingofinlet/outletconnectionsasperbye-lawsetc complete
i)5000litrescapacity
ii)2000litrescapacity
iii)1000litrescapacity
Providing,fixinggunmetalnonreturnvalveofapprovedquality 80mm 65mm 50mm 40mm 32mm
ProvidingandfixingapprovedISImarkedmakeCIflangedwatermetersdirect readingtypecalibratedinlitres&kilolitrestestedandapprovedbyMCGMwithdirt box(strainer)includingmakingnecessaryflangedjoints,testingetc complete 40mmsize
50mmsize
Constructingbrickmasonryvalve&meterchambersin230mmthickbrickmasonry incementmortar15usingfirstclassbricksconstructedoverabedof150mmthick cementconcrete1:2:4plasteringinsideoutsideandallexposedsurfacewith 20mmthickcementmortar13 finishing'insidewithafloatingcoatofneatcement providing&fixingCIframe&coversize, weightmentionedbelowpaintingallCI itemswith3coatsofapprovedbitumasticpaintetc complete
Chamber600x600mmclearinsidewith600x600CIframe&coverweightingnot lessthan72kgms Depthofchambernotexceeding1000mm
ProvidingStructuralsupportforpipelinesusingchannels,tees,angles,flats& platesfabricationbycuttingthreading&weldingifrequired,applyingonecoatof redoxideprimerandthreecoatsofsyntheticenamelpaint,includingnecessary boltsnuts,washeretc asrequiredbytheEngineer-in-charge Theweightofthe supportshallbecalculatedonthebasisofcatalogueweightsofsectionsused (weightofbolts,nutsetc willnotbeconsidered)
Providing&fixingbrassfloatvalveswithbrassrodandcopperfloat suitableto withstandapressure2 kg/sqcm
50mmnb
40mmnb
Excavationintrenchesforpipelinesofrequiredwidthanddepthasdirectedby Engineer-in-chargeincludingtrimmingbottomandsides,excavationforsockets includingrefillingwithselectedexcavatedmaterial(afterlayingofpipeline)in 200mmlayers,wateringconsolidationdisposalofsurplusearthwithin50metc complete
Inordinarysoil(forCIpipelineslaidoutsidethebuildingonly)depthnotexceeding 15m
-Do-insoftrock
ProvidingandfixingbestIndianmakeCPbrassairvalveswithisolationvalvefixed onGIlines
15mmnbairvalvewith15mmisolationvalve
20mmnbairvalvewith20mmisolationvalve
Providingconnectionstoequipments(Kitchen/Laundryetc includingprovisionof controlvalve runningjointwithunionetc complete
65mmconnections
50mmconnections
40mmconnections
32mmconnections
25mmconnections
20mmconnections
15mmconnections
SupplyingandinstallingBourdentypepressuregaugesrange0to20Kg/sqcm calibratedbothinpsiandkg/sqcm with10mmbrassgaugecocketc complete
Providingandfixingpipesleevesupto600mmlong,cutfromheavyqualityMS pipesconformingtoIS1239or3589(dependingonsizeofpipewithMSflange conformingtotable13ofIS 6392onbothendsanda6mmpuddleflangeatthe centreofthesleeve,allflangesweldedtopipe,fixingthesleeveinpositionbytack weldingtoreinforcementetc complete
40mmnb
50mmnb
65mmnb
80mmnb
100mmnb
Forthepurposeofthiscourseanapproximateamountisbudgeted
Providingandfixingcastiron traps of selfcleansing design with watersealnot lessthan50mmwith or without vent,including setting the trapin1:2:4cement concreteetc complete Thetrapshall be P' or S'type as required Trapwith 100mm inlet and100mmdiaoutlet
Asinitem31buttrapwith75mmoutlet
Asinitem31buttrapinPVC
Asinitem32butwithPVCtrap
Providingandfixingstainless steel gratingof 18 gaugethick,withcircular perforationofapprovedpatternoverCItraps Thegratingshallbeofsize100mmx 100mmorcircularof100mmdia(asdirected) and shallbesetin cement,sand mortar1:3etc complete
-Do-gratingofsize150mmx150mm
Providing, fixing, jointingand testingPVCWCpanconnectorofapprovedcolour with or withoutvent horn all as perrequirementsofEngineer-in-charge Size 100mmi/d-Length300mmto400mm
Supplying,laying,fixingjointing&testingheavyISImarkedcastiron spun soil pipes/centricastpipesincludingallfittingswithorwithoutinspectiondoors vents cowls at topetc jointing with leadcaulked joints all as perspecification and as directedbyEngineer-in-charge 150mmi/d 100mmi/d
Providing, laying, jointing with screwed jointsusing teflon tape GI pipesof classTataorZenithconformingtoclassheavyofIS1239withallfittingstestingthe piping, painting with 2coatsofbitumasticpaintwrapping with Hasseinfaced polyethylenetapeintwo layers and againpaintingwith2coatsofbitumastic paint Therateincludesforcuttingchasesinwall&floorsforembeddingthepipe andreinstatementofsurfacetooriginalconditions 50mmi/d 40mmi/d 32mmi/d
Providing and fixing inposition cast iron rain water inlets withgravelguard anddometypegratingspeciallycastgenerallyconformingtodrgs
Inletfor:
150mmi/dpipes
100mmi/dpipes
Providing and fixingleadsheet flashing madeoutof3mmthickleadsheets settinginalayerofcoldbitumenetc complete Thesheetshallprojectatleast 150mmallaroundthepipeand shallbetuckedintothepipeatleastby100mm
150mmi/dpipes
100mmi/dpipes
ProvidingandfixingMSsupportsforpipesfabricatedfromMSflatsanglesand platesincludingfixingthebracketstowalls,slab,beametc withanchor,fasteners 12mm'U'or'J'boltsforfixingthepipestoclamppaintingwithonecoatofprimer andtwocoatsofapprovedpaintetc complete
Providingandlayingcementconcrete1:2:4forbedding,envelopeshaunchesetc forthepipesincludingmixingplacingformworkcuringetc complete
SupplyinglayingfixingjointingandtestingPVCdrainagesystem(SWR)including fittingswithorwithoutinspectiondoors,vents,cowlsetc allasdirectedby engineerincharge
110OD
75OD
ProvidingandfixingPVCplainor multi floor traps of selfcleansingdesignwith watersealnotlessthan50mmwithorwithoutventincludingsettingthetrapsin cementmortaretc complete Trapswith125mminletand75mmoutlets
Providingcleanoutsincastiron drainpipingcomprisingGIheavyclasssocket andscrewed plug,connectingCI pipewithleadcaulked jointetc complete
150mm 100mm
75mm
Supply,laying,jointingandtestingPVCpipesincludingallmouldedfittings conformingtoIS4985(10Kg/sqcmvariety)etc complete
50mm OD
40mm OD
32mm OD
ProvidingandfixinginpositionheavyISImarkedlongarmCI nahanitrapofIS 1729weighing9kgofNecoorEquivalentmakeofsize100x75x500mmdiaoutlet includingembeddingonflooringatrequiredlevelwithM150cementconcreteall aroundandbelowthetrap,supplyingandfixingbrassCPsquaregratingofsizeof 150x150mmwithbrassCPcoverplateasspecifiedetc complete
Providing fixingandjointinginproperalignment&positionheavyISImarked 50mmdia CI pipeofNecoorEquivalentforventconformingtoIS1729withall necessaryfittings,likeoffset,bend,cowletc includingerectionofscaffoldingat requiredlevel,makingholesinwallsasrequired,fixingofpipe&fittinginposition, leadjointing/fillingofjointswithCM1:3(onlyonapprovalofconsultant) reinstatementofsurfacesetc complete
Providing,fixingandjointinginproperalignment&positionheavyISImarkedCI CentripipesofKapilanshorEquivalentmake(withinbuildingline)fordrainage conformingtoIS3929of150mmdiameter sizewithallnecessaryfittings,like offset,bend,etc includingexcavationuptorequiredlevel,makingholesinwallsif required,layingofpipeatpropergradient,leadjointing/fillingofjointswithCM1:3 (onlyonapprovalofconsultant),reinstatementofsurfacesetc complete
Providingandconstructing300x300mminternalsizebrickmasonrygullytrap chamberincludinglayingof100mmthickPCC1:3:6inbed 115mmthickbrick wallsinCM1:5,fixingofglazedstonewaregullytrapofsize150x100mm, makingconnectionofwastewaterpipetoit,plasteringinsidethechamberwithCM 1:3toformhopper,fixingofheavyCI coverwithframeweighingnotlessthan7 kg inPCC1:2:4&makingflooringlevelontopetc complete
Providing,layingandjointingISImarkedfirstquality A’gradesaltglazed stonewarepipe&bend,includingexcavationtothelevelofrequireddepth,laying of100mmthickPCC,placingofpipeonPCCasspecifiedatproperalignmentand gradient sealingthejointswithtarredgasketofhemporropeyarn caulkingwith cementmortar1:2,testingofpipeline,encasingofpipeasspecified,curing, refillingetc complete
i)100mmdia
ii)150mmdiafordepthbetween045and060Mtrs
iii)150mmdiafordepthbetween060and100Mtrs
Providing&fixing150mmdiameterISImarkedfirstquality Agradesaltglazed stonewaresewertrapasspecified
i)150mmdiameter
Constructingbrickmasonryinspectionchamberofsizeof900x450mmanddepth asmentionedinitw\esmbelowincludingexcavationupto requireddepth,layingof 100mmthickPCCfoundationbedin1:3:6mix 230mmthickbrickworkinCM1:3 20mmthickplasteringofwallsinside&outsideasspecified,makingofsmooth channel&haunchinCM1:2,150mmthickPCCcopingontop,fixingofCI manholecoverofNecomakeweighingnotlessthan75kg,backfilling,removalof surplusearthasspecifiedetc complete
i)Depthbetween045and060m
ii)Depthbetween060and100m
TOTALOFSECTION-VI
Providingandlayingmultiplelayersovertheinternalcourtyardforwaterproofing