FOR THE AUTOMATION OF BLINDS AND SHADES
vertilux.com
For the Automation of Blinds and Shades
The Vertilux Motorization systems eliminate the need for manual operation of Blinds and Shades creating a merger between the vanguard in technology and decorative style while at the same time keeping a balance in making it a cost effective solution.
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Benefits
Motorized blinds and draperies were thought of as an indulgence available only to the elite several years ago. But today’s hardware, technology and pricing have made this onetime luxury easily available to the general public. Motorized blinds, shades and draperies offer many benefits for many people. Parents with young children, the elderly and even just the average person will benefit from having motorized window coverings, which eliminate the need to fuss with wands or cords. If you suffer from mobility or dexterity issues, or are just tired of dealing with tangled cords, this investment can help your window coverings function flawlessly and look spectacular Motorization can be used for virtually any type of window treatment, from blinds to shades to drapery. Even those high windows you can hardly reach enough to clean can suddenly have window treatments you can operate with ease, thanks to motorization. As one of the most revolutionary trends in the industry, motorized operating systems offer the convenience and luxury of controlling your window covers from the comfort of your bed, sofa, and dining room table – anywhere you like. However, motorization is more than just a convenience. It also offers increased energy efficiency and safety, a true win-win in many aspects. In residential applications with just the click of a button, motorization allows you to raise and lower treatments, adjust slats and vanes, rotate and move from side to side, all with the ease and simplicity of a battery operated remote. Just point and press! However, you can even take it one step further, with hard-wired technology, with a home automation system. When your windows are very high, a motorized shade can help maximize functionality. I would recommend that an installation like this be hardwired with either a remote or wall switch, so you can avoid having to get the ladder out to change the batteries. If you have a large window, the weight of one blind can sometimes be too heavy for one person to lift. This is a perfect situation for a motorized blind. Hard wired motorization enables you to control your window coverings through a switch on your wall, just like a light switch, which fits seamlessly with any décor. You can program various positions for your window treatments and still benefit from the use of an integrated remote. With hard wired motorization, you’ll enjoy extreme accuracy and precision.
5
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Vertilux Rechargeable Battery Motor
MODEL: 6-700-CM-25 E02
Internal Rechargeable Battery
ITEM CODE: 6-700-CM-25E02
Radio Frequency
Technical Specifications Item Code:
6-700-CM-25E02
Motor Diameter:
Series 25mm
Motor Length:
16 in
Functional Tubes:
Keyed 1.5” (38mm) Tube
Limits:
Electronic
Time of Operation:
4 Minutes
Power:
DC 12V. Internal Battery
Recommended use:
Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Amps:
900m A.
1 Nm | 30 RPM
Output:
Weight Capacity Tube Diameter 1.5”
7
44mm /
kg
lb
3.7
8.2
kg
NM: 1.0
50mm / lb
kg
55mm / lb
60mm /
RPM: 30 65mm /
78mm /
kg
lb
kg
lb
kg
lb
kg
lb
-
-
-
-
-
-
-
-
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Neolux Roller Shades with Rechargeable Battery Motor 84”
5
6 4
84”
3
Maximum Shade Size*
7 2
3 8 1 9
0.75 '' LG Motor
Light Gap = LG Measurement include adapters
5
0.5 '' LG End Plug
*Measurements will vary depending on the fabric
Battery System for Neolux Dual Shades and Roller Shades Individual Components Itemized No. 1
Item NO.
Description
Unit
6-700-CM-25E02
Celtic II Battery Motor Internal Power
1
EA
0-149-12-CAVXX
Rollux- Aluminum Cassette 120 *
1
EA
0-149-10-CAVXX
Rollux- Aluminum Cassette 100 **
1
EA
0-149-12-BR08I
Rollux- Cassette 120 Bracket
2
EA
0-149-10-BR08I
Vertilux- Cassette 100 Bracket
2
EA
0-149-08-E38WH
Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White
1
EA
0-149-12-CO0XX
Rollux- Cassette 120 End Cover ***
2
EA
0-149-10-CO0XX
Rollux- Cassette 100 End Cover ****
2
EA
0-149-12-BRMWH
Rollux- Cassette 120 Mounting Bracket White
3
EA
0-149-10-BRMWH
Rollux- Cassette 100 Mounting Bracket
3
EA
7
6-200-60-70427
Motor Plate for 400 Series Motor
1
EA
8
0-154-TU-00038
Rollux 1 1/2” (38mm) Aluminum Tube with Tape 16’ Mill Finish *****
-
-
9
6-700-CM-DC001
Celtic ll Charger for Battery Motor with Internal Battery
1
EA
2 3 4 5 6
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. ***** Maximum recommended tube length is 7 FT.
9
Qty
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Vertilux Rechargeable Battery Motor with Solar Panel
MODEL: 6-700-CM-25 E01
External Battery Wand
ITEM CODE: 6-700-CM-25E01
Radio Frequency
Technical Specifications Item Code:
6-700-CM-25E01
Motor Diameter:
Series 25mm
Motor Length:
16 in
Functional Tubes:
Keyed 1.5” (38mm) Tube
Limits:
Electronic
Time of Operation:
4 Minutes
Power:
DC 12V. Ext. Power: Battery Wand, Solar Panel
Recommended use:
Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Amps:
900m A.
Output:
1 Nm | 30 RPM
Weight Capacity Tube Diameter 1.5”
11
44mm /
kg
lb
3.7
8.2
kg
NM: 1.0
50mm / lb
kg
55mm / lb
60mm /
RPM: 30 65mm /
78mm /
kg
lb
kg
lb
kg
lb
kg
lb
-
-
-
-
-
-
-
-
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Neolux & Roller Shade Battery System
5
84”
6 4
84”
Maximum Shade Size*
3 7 2
3 8
1 5
0.75 '' LG Motor
Light Gap = LG Measurement include adapters
0.5 '' LG End Plug
9 *Measurements will vary depending on the fabric
Battery System for Neolux Dual Shades and Roller Shades Individual Components Itemized No. 1
Item NO.
Description
Unit
6-700-CM-25E01
Celtic II Battery Motor External Power
1
EA
0-149-12-CAVXX
Rollux- Aluminum Cassette 120 *
1
EA
0-149-10-CAVXX
Rollux- Aluminum Cassette 100 **
1
EA
0-149-12-BR08I
Rollux- Cassette 120 Bracket
2
EA
0-149-10-BR08I
Vertilux- Cassette 100 Bracket
2
EA
0-149-08-E38WH
Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White
1
EA
0-149-12-CO0XX
Rollux- Cassette 120 End Cover ***
2
EA
0-149-10-CO0XX
Rollux- Cassette 100 End Cover ****
2
EA
0-149-12-BRMWH
Rollux- Cassette 120 Mounting Bracket White
3
EA
0-149-10-BRMWH
Rollux- Cassette 100 Mounting Bracket
3
EA
7
6-200-60-70427
Motor Plate for 400 Series Motor
1
EA
8
0-154-TU-00038
Rollux 1 1/2” (38mm) Aluminum Tube with Tape 16’ Mill Finish *****
-
-
9
6-700-01-BPOLE
Battery Pole
2
EA
2 3 4 5 6
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. ***** Maximum recommended tube length is 7 FT.
13
Qty
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Vertilux Motor 35mm Series
MODEL: 6-700-CM- 35E10
ITEM CODE: 6-700-CM-35E10 Radio Frequency
Technical Specifications Item Code:
6-700-CM-35E10
Motor Diameter:
Series 35mm
Motor Length:
24 in
Functional Tubes:
Round Smooth 40mm - 50mm
Limits:
Electronic
Time of Operation:
4 Min
Power:
AC 120V.50/60 Hz
Recommended use:
Neolux Dual Shades and 2” Horizontal Blinds
Amps:
0.96 A
10 Nm | 15 RPM
Output:
Weight Capacity Tube Diameter 40 mm / 1.57”
15
44mm / 1.73”
NM: 6
50mm / 2”
55mm / 2.16”
60mm / 2.375”
RPM: 33 63mm / 2.5”
78mm / 3”
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
15
33
13.63
30
12
26.4
-
-
-
-
-
-
-
-
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Neolux Dual Shade System 108”
5
6 4
108”
Maximum Shade Size*
9
3
7 2
3
8 1
0.75 '' LG Motor
5
Light Gap = LG Measurement include adapters
0.5 '' LG End Plug
*Measurements will vary depending on the fabric
System for Neolux Dual Shades and Roller Shades Individual Components Itemized No. 1
Item NO.
Description
Unit
6-700-CM-35R06
Celtic II 35MM RF Motor 120V/33 RPM / 6NM
1
EA
0-149-12-CAVXX
Rollux- Aluminum Cassette 120 *
1
EA
0-149-10-CAVXX
Rollux- Aluminum Cassette 100 **
1
EA
0-149-12-BR08I
Rollux- Cassette 120 Bracket
2
EA
0-149-10-BR08I
Vertilux- Cassette 100 Bracket
2
EA
0-154-EW-CA038
Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White
1
EA
0-149-12-CO0XX
Rollux- Cassette 120 End Cover ***
2
EA
0-149-10-CO0XX
Rollux- Cassette 100 End Cover ****
2
EA
0-149-12-BRMWH
Rollux- Cassette 120 Mounting Bracket White
3
EA
0-149-10-BRMWH
Rollux- Cassette 100 Mounting Bracket
3
EA
7
6-200-60-70427
Motor Plate for 400 Series Motor
1
EA
8
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finished *****
-
-
9
6-700-AS-35040
Celtic II Crown and Drive (40mm) mm
1
EA
2 3 4 5 6
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. ***** Maximum recommended tube length is 10 FT.
16
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II - 2” Horizontal Blinds System 120”
4
9
120”
Maximum Shade Size*
8 6 7 6 6
5
4 3
6 2
1 3 *Measurements will vary depending on the fabric
System for Roman Shades and Wood Blinds Individual Components Itemized No.
Item NO.
Description
1
0-074-50-WXXXH
Louverlux - 2" Headrail *
2
0-098-CA-01100
3
Qty 192 FT
BOX
Louverwood - 2" Center Support Bracket
1
EA
0-098-ES-XXXX
2" Inst. Brackets White Satin (Pair)
1
EA
4
6-200-60-80251
Motor/Idler Bkt for 2" Headrail (LS40)
2
EA
5
6-200-60-90186
40mm Octagonal End Cap 40/8
1
EA
6
6-200-61-80391
40mm CTS Kit (Cone CTS 40) 1
-
EA
7
6-200-60-50521
40 mm Octagonal Tube **
-
-
8
6-700-CM-35E10
Celtic II RF Electric Motor 120V/ 17rpm/ 35mm/ 10Nm
1
EA
9
6-700-AS-35OCT
Celtic II Crown & Drive (Octagonal) for CM35 Motors
1
EA
* Quantities depend on size of shade. Substitute XXX by 700=Natural, 708=White Birch, 710=Bleach Wood, 722=Sugar Maple, 726=Golden Oak, 728=Cherry. ** Maximum recommended tube length is 10 FT.
17
Unit
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Vertilux 35 mm Motor, 6 Nm, Mechanical Limits
MODEL: 6-700-CM- 35R06
ITEM CODE: 6-700-CM-35R06
Radio Frequency
Technical Specifications Item Code:
6-700-CM-35R06
Motor Diameter:
Series 35mm
Motor Length:
24 in
Functional Tubes:
Round Smooth 40mm - 50mm
Limits:
Mechanical
Time of Operation:
4 Min
Power:
AC 120V.50/60 Hz
Recommended use:
Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Amps:
0.96 A
6 Nm | 33 RPM
Output:
Weight Capacity Tube Diameter 40 mm / 1.57”
19
44mm / 1.73”
NM: 6
50mm / 2”
55mm / 2.16”
60mm / 2.375”
RPM: 33 63mm / 2.5”
78mm / 3”
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
15
33
13.63
30
12
26.4
-
-
-
-
-
-
-
-
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Roller Shade System 120”
4 2
120”
Maximum Shade Size*
9 4 2
8
3
1 7 5 6 0.5'' LG Motor
Light Gap = LG Measurement include adapters
0.5'' LG End Plug
3
*Measurements will vary depending on the fabric
Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-35R06
Celtic II 35MM RF Motor 120V/33 RPM / 6NM
1
EA
2
0-154-PB-00300
Celtic Universal Bracket (CUB) Small Female Bracket
2
EA
3
0-154-PC-001XX
Celtic Universal Bracket (CUB) Small Bracket Cover *
2
EA
4
0-154-PC-003XX
Celtic Universal Bracket (CUB) Small Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) 38mm End Plug - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) 38mm End Plug - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-in End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-in End Support - Black
1
EA
7
6-700-AS-35040
Celtic II Crown and Drive (40mm) for CM 35 Motors mm
1
EA
8
6-700-BR-SQ001
Installation 10mm Motor Block
1
EA
9
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finish **
-
-
5 6
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 10 FT.
20
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Cassette Roller Shade System 120”
5
6 4
120”
Maximum Shade Size*
9
3
7 2
3
8 1
0.75 '' LG Motor
5
Light Gap = LG Measurement include adapters
0.5 '' LG End Plug
*Measurements will vary depending on the fabric
System for Neolux Dual Shades and Roller Shades Individual Components Itemized No. 1
Item NO.
Description
Unit
6-700-CM-35R06
Celtic II 35MM RF Motor 120V/33 RPM / 6NM
1
EA
0-149-12-CAVXX
Rollux - Aluminum Cassette 120 *
1
EA
0-149-10-CAVXX
Rollux - Aluminum Cassette 100 **
1
EA
0-149-12-BR08I
Rollux - Cassette 120 Bracket
2
EA
0-149-10-BR08I
Vertilux - Cassette 100 Bracket
2
EA
0-154-EW-CA038
Rollux - Cassette 100/120 End Plug 1 1/2" (38mm) White
1
EA
0-149-12-CO0XX
Rollux - Cassette 120 End Cover ***
2
EA
0-149-10-CO0XX
Rollux - Cassette 100 End Cover ****
2
EA
0-149-12-BRMWH
Rollux - Cassette 120 Mounting Bracket White
3
EA
0-149-10-BRMWH
Rollux - Cassette 100 Mounting Bracket
3
EA
7
6-200-60-70427
Motor Plate for 400 Series Motor
1
EA
8
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finished *****
-
-
9
6-700-AS-35040
Celtic II Crown and Drive (40mm) mm
1
EA
2 3 4 5 6
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. ***** Maximum recommended tube length is 10 FT.
21
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II -
Intermediate Double Motorized Roller Shade System, Mechanical Limits
120” 5 3
Maximum Shade Size*
120” 1 11
12 9
4
5 12
3
8 6
10 0.5'' LG Motor
Light Gap = LG Measurement include adapters
0.5'' LG End Plug
7 *Measurements will vary depending on the fabric
4
Roller Shade System Components with Intermediate Bracket Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-35R06
Celtic II 35MM RF Motor 120V/33 RPM / 6NM
1
EA
2
0-154-AD-RA250
Rollux End Plug Adapter 2” (50mm) Tube
1
EA
3
0-154-PB-00300
Celtic Universal Bracket (CUB) Small Female Bracket
2
EA
4
0-154-PC-001XX
Celtic Universal Bracket (CUB) Small Bracket Cover *
2
EA
5
0-154-PC-003XX
Celtic Universal Bracket (CUB) Small Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) 38mm End Plug - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) 38mm End Plug - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-in End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-in End Support - Black
1
EA
8
6-700-AS-35050
Celtic II Crown and Drive 50 mm
1
EA
9
6-700-BR-SQ001
Installation 10mm Motor Block
1
EA
10
6-700-AD-DL170
Celtic Drive (50mm) for VM35 Motors
2
EA
11
6-700-BR-DZ131
Center Support Bracket for 35mm Motors **
1
EA
12
0-154-TU-3MM50
Rollux 3x50mm Alluminum Tube / no Tape ***
6 7
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** The center support bracket reduces motor’s performance by approximately 15% *** Maximum recommended tube length is 10 FT.
22
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Motorized Roller Shade with Hook Mount (HM) System, Mechanical Limits 96” 118” 4
Maximum Shade Size*
4
2
3 1 2
5 0.5” LG Motor
Light Gap = LG Measurement include adapters
6
0.5” LG End Plug
*Measurements will vary depending on the fabric
Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-35R06
Celtic II 35MM RF Motor 120V/33 RPM / 6NM
1
EA
2
0-155-BW-SL020
Universal Bracket 2” Hook SL-20
2
EA
3
0-155-EW-SLH53
Heavy Duty End Cap 38 mm Hook
1
EA
4
6-700-BR-4SLAM
Rollux-CUB Motor Support Black for 35 Motors
1
EA
5
6-700-AS-35040
Celtic II Crown and Drive (40mm) for CM 35 Motors
1
EA
6
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finished *
-
-
* Maximum recommended tube length is 8 FT.
23
Qty
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Vertilux 35 mm Motor, 6 Nm, Electronic limits
MODEL: 6-700-CM- 35E06
ITEM CODE: 6-700-CM-35E06
Radio Frequency
Technical Specifications Item Code:
6-700-CM-35E06
Motor Diameter:
Series 35mm
Motor Length:
24 in
Functional Tubes:
Round Smooth 40mm - 50mm
Limits:
Electronic
Time of Operation:
4 Min
Power:
AC 120V.50/60 Hz
Recommended use:
Roller Shades, Screens, Blackout, Neolux Dual Shades, etc...
Amps:
0.96 A
6 Nm | 33 RPM
Output:
Weight Capacity Tube Diameter 40 mm / 1.57”
25
44mm / 1.73”
NM: 6
50mm / 2”
55mm / 2.16”
60mm / 2.375”
RPM: 33 63mm / 2.5”
78mm / 3”
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
15
33
13.63
30
12
26.4
-
-
-
-
-
-
-
-
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Roller Shade System 120”
4 2
120”
Maximum Shade Size*
9 4 2
8
3
1 7 5 6 0.5'' LG Motor
Light Gap = LG Measurement include adapters
0.5'' LG End Plug
3
*Measurements will vary depending on the fabric
Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-35E06
Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM
1
EA
2
0-154-PB-00300
Celtic Universal Bracket (CUB) Small Female Bracket
2
EA
3
0-154-PC-001XX
Celtic Universal Bracket (CUB) Small Bracket Cover *
2
EA
4
0-154-PC-003XX
Celtic Universal Bracket (CUB) Small Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) 38mm End Plug - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) 38mm End Plug - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-in End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-in End Support - Black
1
EA
7
6-700-AS-35040
Celtic II Crown and Drive (40mm) for CM 35 Motors mm
1
EA
8
6-700-BR-SQ001
Installation 10mm Motor Block
1
EA
9
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finish **
-
-
5 6
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 10 FT.
26
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Cassette Roller Shade System 120”
5
6 4
120”
Maximum Shade Size*
9
3
7 2
3
8 1
0.75 '' LG Motor
5
Light Gap = LG Measurement include adapters
0.5 '' LG End Plug
*Measurements will vary depending on the fabric
System for Neolux Dual Shades and Roller Shades Individual Components Itemized No. 1
Item NO.
Description
Unit
6-700-CM-35E06
Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM
1
EA
0-149-12-CAVXX
Rollux- Aluminum Cassette 120 *
1
EA
0-149-10-CAVXX
Rollux- Aluminum Cassette 100 **
1
EA
0-149-12-BR08I
Rollux- Cassette 120 Bracket
2
EA
0-149-10-BR08I
Vertilux- Cassette 100 Bracket
2
EA
0-154-EW-CA038
Rollux- Cassette 100/120 End Plug 1 1/2" (38mm) White
1
EA
0-149-12-CO0XX
Rollux- Cassette 120 End Cover ***
2
EA
0-149-10-CO0XX
Rollux- Cassette 100 End Cover ****
2
EA
0-149-12-BRMWH
Rollux- Cassette 120 Mounting Bracket White
3
EA
0-149-10-BRMWH
Rollux- Cassette 100 Mounting Bracket
3
EA
7
6-200-60-70427
Motor Plate for 400 Series Motor
1
EA
8
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finished *****
-
-
9
6-700-AS-35040
Celtic II Crown and Drive (40mm) mm
1
EA
2 3 4 5 6
* Substitute XX by WH=White, IV=Ivory, BK=Black, BZ=Bronze. ** Substitute XX by WH=White, IV=Ivory, SA=Satin Anodized, BZ=Bronze, BK=Black. *** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. **** Substitute XX by WH=White, IV=Ivory, GR=Silver Gray, BZ=Bronze, BK=Black. ***** Maximum recommended tube length is 10 FT.
27
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II -
Intermediate Double Motorized Roller Shade System, Electronic Limits
120” 5 3
Maximum Shade Size*
120” 1 11
12 9
4
5 12
3
8 6
10 0.5'' LG Motor
Light Gap = LG Measurement include adapters
0.5'' LG End Plug
7 4
*Measurements will vary depending on the fabric
Roller Shade System Components with Intermediate Bracket Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-35E06
Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM
1
EA
2
0-154-AD-RA250
Rollux End Plug Adapter 2” (50mm) Tube
1
EA
3
0-154-PB-00300
Celtic Universal Bracket (CUB) Small Female Bracket
2
EA
4
0-154-PC-001XX
Celtic Universal Bracket (CUB) Small Bracket Cover *
2
EA
5
0-154-PC-003XX
Celtic Universal Bracket (CUB) Small Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) 38mm End Plug - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) 38mm End Plug - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-in End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-in End Support - Black
1
EA
8
6-700-AS-35050
Celtic II Crown and Drive 50 mm
1
EA
9
6-700-BR-SQ001
Installation 10mm Motor Block
1
EA
10
6-700-AD-DL170
Celtic Drive (50mm) for VM35 Motors
2
EA
11
6-700-BR-DZ131
Center Support Bracket for 35mm Motors **
1
EA
12
0-154-TU-3MM50
Rollux 3x50mm Alluminum Tube / no Tape ***
-
-
6 7
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** The center support bracket reduces motor’s performance by approximately 15% *** Maximum recommended tube length is 10 FT.
28
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II -
Motorized Roller Shade with Hook Mount (HM) System, Electronic Limits
96” 118” 4
Maximum Shade Size*
4
2
3 1 2
5 0.5” LG Motor
Light Gap = LG Measurement include adapters
6
0.5” LG End Plug
*Measurements will vary depending on the fabric
Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-35E06
Celtic II 35MM RF Electronic Motor 120V/33 RPM / 6NM
1
EA
2
0-155-BW-SL020
Universal Bracket 2” Hook SL-20
2
EA
3
0-155-EW-SLH53
Heavy Duty End Cap 38 mm Hook
1
EA
4
6-700-BR-4SLAM
Celtic Universal Bracket (CUB) Motor Support Black for 35 Motors
1
EA
5
6-700-AS-35040
Celtic II Crown and Drive (40mm) for CM 35 Motors
1
EA
6
0-151-TU-00002
Rollux 1.5” Motor Tube Mill Finished *
-
-
* Maximum recommended tube length is 8 FT.
29
Qty
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Vertilux Ultra Quiet Motor 45mm Series
6-700-RC-00001
ITEM CODE: 6-700-RC-00001
Radio Frequency
Technical Specifications Item Code:
6-700-RC-00001
Motor Diameter:
Series 45mm
Motor Length:
30 in
Functional Tubes:
Round Smooth 2” - 2 1/2” | 63mm
Limits:
Mechanical
Time of Operation:
4 Min
Power:
AC 120V.50/60 Hz
Recommended use:
Roller Shades
Amps:
0.97 A
4 Nm | 33 RPM
Output:
Weight Capacity Tube Diameter 40 mm / 1.57”
31
44mm / 1.73”
NM: 4
50mm / 2”
55mm / 2.16”
60mm / 2.375”
RPM: 33 63mm / 2.5”
78mm / 3”
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
-
-
-
-
12
26
-
-
-
-
9.53
21.16
-
-
Vertilux CELTIC II - Technical Catalogue
CELTIC II -
Ultra Quiet Motor, 4 Nm, for Single Roller Shade on 2” Tube
144”
5 3
144”
Maximum Shade Size*
8
5
10 4
9
3
2 1
6 7 w/o cover 0.5” w/cover 0.75”
LG Motor
Light Gap = LG Measurement include adapters
w/o cover 0.5” w/cover 0.75”
*Measurements will vary depending on the fabric
LG End Plug
4
System for Ultra Quiet Roller Shade Individual Components Itemized No.
Item NO.
1
6-700-RC-00001
Celtic II RF Quiet Motor 120V / 33 rpm / 45 mm / 4 Nm
1
EA
2
0-154-AD-GA025
Rollux - Galaxy Adapter for 2.5" (63mm) Tube White
1
EA
3
0-154-PB-00400
Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor)
2
EA
4
0-154-PC-002XX
Celtic Universal Bracket (CUB) Large Bracket Cover *
2
EA
5
0-154-PC-004XX
Celtic Universal Bracket (CUB) Large Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-In End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-In End Support - Black
1
EA
8
6-700-AS-45063
Roller Crown & Drive Adaptor Set for 2.5" (63mm) Tube
1
EA
9
6-700-BR-SQ001
Installation 10mm Motor Block
1
EA
10
0-154-TU-3MM50
Rollux - 3x50mm Aluminum Tube / no Tape **
-
-
6 7
Description
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.
32
Vertilux CELTIC II - Technical Catalogue
Qty
Unit
CELTIC II -
Ultra Quiet Motor, 4 Nm, for Single Roller Shade on 2.5” Tube
144”
5 3
Maximum Shade Size*
144” 1
5
10 9
4
2
8
3
6 7
w/o cover 0.5” w/cover 0.75”
LG Motor
w/o cover 0.5” w/cover 0.75”
Light Gap = LG Measurement include adapters
LG End Plug
4
*Measurements will vary depending on the fabric
System for Ultra Quiet Roller Shade Individual Components Itemized No.
Item NO.
1
6-700-RC-00001
Celtic II RF Quiet Motor 120V / 33 rpm / 45 mm / 4 Nm
1
EA
2
0-154-AD-GA025
Rollux - Galaxy Adapter for 2.5" (63mm) Tube White
1
EA
3
0-154-PB-00400
Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor)
2
EA
4
0-154-PC-002XX
Celtic Universal Bracket (CUB) Large Bracket Cover *
2
EA
5
0-154-PC-004XX
Celtic Universal Bracket (CUB) Large Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-In End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-In End Support - Black
1
EA
8
6-700-AS-45063
Roller Crown & Drive Adaptor Set for 2.5" (63mm) Tube
1
EA
9
6-700-BR-SQ001
Installation 10 mm Motor Block
1
EA
10
0-154-TU-00063
Rollux 2.5” 63 mm Alluminum Tube W/ Tape **
-
-
6 7
Description
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 19 FT.
33
Vertilux CELTIC II - Technical Catalogue
Qty
Unit
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Vertilux 20 Nm Motor for Large Roller Shade, Electronic Limits
6-700-CM-45E20
ITEM CODE: 6-700-CM-45E20
Radio Frequency
Technical Specifications Item Code:
6-700-CM-45E20
Motor Diameter:
Series 45mm
Motor Length:
29 in
Functional Tubes:
2” Smooth - 2 1/2” | 70 & 78mm
Limits:
Electronic
Time of Operation:
4 Min
Power:
AC 120V.50/60 Hz
Recommended use:
Oversize Roller Shades
Amps:
0.98 A
20 Nm | 33 RPM
Output:
Weight Capacity Tube Diameter 40 mm / 1.57”
35
44mm / 1.73”
NM: 20
50mm / 2”
55mm / 2.16”
60mm / 2.375”
RPM: 33 63mm / 2.5”
78mm / 3”
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
-
-
-
-
40
88
-
-
-
-
33.3
73.3
30.5
67.2
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Oversize Roller Shade System 144”
5 3
144”
8 4
Maximum Shade Size*
5
10 2
9
3
1
6 7 w/o cover 0.75” w/cover 1”
LG Motor
w/o cover 0.5” w/cover 0.75”
Light Gap = LG Measurement include adapters
LG End Plug
4
*Measurements will vary depending on the fabric
Oversize Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-45E20
Celtic II RF Electronic Motor 120V / 33 rpm / 45mm / 20Nm
1
EA
2
0-154-AD-RA250
Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) Tube Vanilla
1
EA
3
0-154-PB-00400
Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor)
2
EA
4
0-154-PC-002XX
Celtic Universal Bracket (CUB) Large Bracket Cover *
2
EA
5
0-154-PC-004XX
Celtic Universal Bracket (CUB) Large Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-In End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-In End Support - Black
1
EA
8
6-700-AS-45050
Celtic II Drive (50mm) for CM45
1
EA
9
6-700-BR-CO45W
Installation Clamp for Celtic II
1
EA
10
0-154-TU-3MM50
Rollux 3 x 50 mm Aluminum Tube / no Tape **
-
-
6 7
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.
36
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II -
Intermediate 20 Nm Motorized System for Oversized Roller Shades, Electronic Limits
144” 4
5
3
Maximum Shade Size*
118”
10
11 9
5
11
1
3
12
2 w/o cover 0.75” w/cover 1”
LG Motor
w/o cover 0.5” w/cover 0.75”
Light Gap = LG Measurement include adapters
6
8
LG End Plug
7 *Measurements will vary depending on the fabric
4
Oversize Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-45E20
Celtic II RF Electronic Motor 120V / 33 rpm / 45mm / 20Nm
1
EA
2
0-154-AD-RA250
Rollux-TM16&TM24 End Plug Adapter for 2"(50mm)
1
EA
3
0-154-PB-00400
Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor)
2
EA
4
0-154-PC-002XX
Celtic Universal Bracket (CUB) Large Bracket Cover *
2
EA
5
0-154-PC-004XX
Celtic Universal Bracket (CUB) Large Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-In End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-In End Support - Black
1
EA
8
6-700-AD-DL170
Celtic Drive (50mm) for VM35 Motors
2
EA
9
6-700-BR-CO45W
Installation Clamp for Celtic II 45mm Motors - White motor
1
EA
10
6-700-BR-DZ131
Center Support Bracket VM35-45 Motors**
1
EA
11
0-154-TU-3MM50
Rollux 3X50 mm Aluminum Tube / no Tape ***
-
-
12
6-700-AS-45050
Celtic II Drive (50mm) for CM45 Motors
1
EA
6 7
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** The center support bracket reduces motor’s performance by approximately 15% *** Maximum recommended tube length is 12 FT With 2” Aluminum Tube
37
Qty
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Vertilux 20 Nm Motor for Large Roller Shade, Mechanical Limits
6-700-CM-45R20
ITEM CODE: 6-700-CM-45R20
Radio Frequency
Technical Specifications Item Code:
6-700-CM-45R20
Motor Diameter:
Series 45mm
Motor Length:
29 in
Functional Tubes:
2” Smooth - 2 1/2” | 70 & 78mm
Limits:
Mechanical
Time of Operation:
4 Min
Power:
AC 120V.50/60 Hz
Recommended use:
Oversize Roller Shades
Amps:
0.98 A
20 Nm | 33 RPM
Output:
Weight Capacity Tube Diameter 40 mm / 1.57”
39
44mm / 1.73”
NM: 20
50mm / 2”
55mm / 2.16”
60mm / 2.375”
RPM: 33 63mm / 2.5”
78mm / 3”
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
lb
-
-
-
-
40
88
-
-
-
-
33.3
73.3
30.5
67.2
Vertilux CELTIC II - Technical Catalogue
CELTIC II - Single Oversize Roller Shade System 144”
5 3
144”
8 4
Maximum Shade Size*
5
10 2
9
3
1
6 7 w/o cover 0.75” w/cover 1”
LG Motor
w/o cover 0.5” w/cover 0.75”
Light Gap = LG Measurement include adapters
LG End Plug
4
*Measurements will vary depending on the fabric
Oversize Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-45R20
Celtic II RF Motor 120V / 33 rpm / 45mm / 20Nm
1
EA
2
0-154-AD-RA250
Rollux-TM16&TM24 End Plug Adapter for 2"(50mm) Tube Vanilla
1
EA
3
0-154-PB-00400
Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor)
2
EA
4
0-154-PC-002XX
Celtic Universal Bracket (CUB) Large Bracket Cover *
2
EA
5
0-154-PC-004XX
Celtic Universal Bracket (CUB) Large Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-In End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-In End Support - Black
1
EA
8
6-700-AS-45050
Celtic II Drive (50mm) for CM45
1
EA
9
6-700-BR-CO45W
Installation Clamp for Celtic II
1
EA
10
0-154-TU-3MM50
Rollux 3 x 50 mm Aluminum Tube / no Tape **
-
-
6 7
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** Maximum recommended tube length is 12 FT.
40
Qty
Vertilux CELTIC II - Technical Catalogue
CELTIC II -
Intermediate 20 Nm Motorized System for Oversized Roller Shades, Mechanical Limits
144” 4
5
3
Maximum Shade Size*
118”
10
11 9
5
11
1
3
12
2 w/o cover 0.75” w/cover 1”
LG Motor
w/o cover 0.5” w/cover 0.75”
Light Gap = LG Measurement include adapters
6
8
LG End Plug
7 *Measurements will vary depending on the fabric
4
Oversize Roller Shade System Components Individual Components Itemized No.
Item NO.
Description
Unit
1
6-700-CM-45R20
Celtic II RF Motor 120V / 33 rpm / 45mm / 20Nm
1
EA
2
0-154-AD-RA250
Rollux-TM16&TM24 End Plug Adapter for 2"(50mm)
1
EA
3
0-154-PB-00400
Celtic Universal Bracket (CUB) Large Female Bracket (HM & Motor)
2
EA
4
0-154-PC-002XX
Celtic Universal Bracket (CUB) Large Bracket Cover *
2
EA
5
0-154-PC-004XX
Celtic Universal Bracket (CUB) Large Bracket Screw Cover *
2
EA
0-154-PE-00501
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - White
1
EA
0-154-PE-03301
Celtic Universal Bracket (CUB) End Plug for 38mm Tube - Black
1
EA
0-154-PS-00500
Celtic Universal Bracket (CUB) Snap-In End Support - White
1
EA
0-154-PS-03300
Celtic Universal Bracket (CUB) Snap-In End Support - Black
1
EA
8
6-700-AD-DL170
Celtic Drive (50mm) for VM35 Motors
2
EA
9
6-700-BR-CO45W
Installation Clamp for Celtic II 45mm Motors - White motor
1
EA
10
6-700-BR-DZ131
Center Support Bracket VM35-45 Motors**
1
EA
11
0-154-TU-3MM50
Rollux 3X50 mm Aluminum Tube / no Tape ***
-
-
12
6-700-AS-45050
Celtic II Drive (50mm) for CM45 Motors
1
EA
6 7
* Substitute XX by 01=White, 02=Black, 03=Vanilla, 04=Brown, 05=Gray, 06=Silver, 07=Titanium, 08=Capri, 09=Champaque, 10=Copper. ** The center support bracket reduces motor’s performance by approximately 15% *** Maximum recommended tube length is 12 FT With 2” Aluminum Tube
41
Qty
Vertilux CELTIC II - Technical Catalogue
vertilux.com
DASHTRACK
The one system for Drapery or Sliding Panel Track motorization
• Traverse up to 165 lbs. of fabric • Compact and lightweight for simple installation • Simple connectivity to home-automation systems • Direct drive rubber belt enables quiet operation • Hard draw technology avoids damage to the product • Dash Track allows draperies to be operated manually, as a fail safe during power outages • Limits are set automatically • Compatible with all Celtic II Controls
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Vertilux Dashtrack, for Draperies and Sliding Panels
Technical Specifications Item Number:
6-700-DM-00001
Weight:
165 lbs.
Motor Dimensions:
12.5 x 2.5 in
Limits:
Automatic
Time of Operation:
4 Min
Power Transformer:
24V
AMP: 2.7 A
Torque:
0.8 NM.
RPM: 7.5 in/s
Recommended use:
Drapery and Sliding Panels.
Radio Frequency
45
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
DASHTRACK FOR PINCH PLEAD DRAPERIES
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Vertilux Dashtrack System
3
3 8
4 10
1
8
6
4
7
System for Pinch Plead Drapery Individual Components Itemized
49
No.
Item NO.
Description
1
6-700-DM-00001
Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W
1
EA
2
6-700-DM-00002
Vertilux Drapery Motors - 24V Transformer
1
EA
3
6-700-DM-00003
Vertilux Drapery Motors - Main Control End
1
EA
4
6-700-DM-00004
Vertilux Drapery Motors - Secondary Control End
1
EA
5
6-700-DM-00005
Vertilux Drapery Motors - Interior Belt
---
FT
6
6-700-DM-00006
Vertilux Drapery Motors - Pinch Plead Carriers
---
EA
7
6-700-DM-00008
Vertilux Drapery Motors - Pinch Plead Master Carrier
---
EA
8
6-700-DM-00009
Vertilux Drapery Motors - Curtain Track - White 19'
---
FT
9
6-700-DM-00010
Vertilux Drapery Motors - Ceiling Clip
---
EA
10
6-700-DM-00011
Vertilux Drapery Motors - Plastic Clip
---
EA
11
0-030-CA-06600
Vertilux-Adj. "L" Bracket 85-145mm White
---
EA
Vertilux CELTIC II - Technical Catalogue
Qty
Unit
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
DASHTRACK FOR RIPPLE FOLD DRAPERIES
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Vertilux Dashtrack System
3
3 8
4 10
1
8
6
4
7
System for Ripple Fold Drapery Individual Components Itemized No.
Item NO.
1
6-700-DM-00001
Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W
1
EA
2
6-700-DM-00002
Vertilux Drapery Motors - 24V Transformer
1
EA
3
6-700-DM-00003
Vertilux Drapery Motors - Main Control End
1
EA
4
6-700-DM-00004
Vertilux Drapery Motors - Secondary Control End
1
EA
5
6-700-DM-00005
Vertilux Drapery Motors - Interior Belt
---
FT
6-700-DM-
Vertilux Drapery Motors - Ripple Fold Carriers 60%
---
FT
6-700-DM-00014
Vertilux Drapery Motors - Ripple Fold Carriers 80%
---
FT
6-700-DM-00015
Vertilux Drapery Motors - Ripple Fold Carriers 100%
---
FT
6-700-DM-00016
Vertilux Drapery Motors - Ripple Fold Carriers 120%
---
FT
7
6-700-DM-00018
Vertilux Drapery Motor - Ripple Fold Master Carrier set
---
Set
8
6-700-DM-00009
Vertilux Drapery Motors - Curtain Track - White 19'
---
FT
9
6-700-DM-00010
Vertilux Drapery Motors - Ceiling Clip
---
EA
10
6-700-DM-00011
Vertilux Drapery Motors - Plastic Clip
---
EA
11
0-030-CA-06600
Vertilux-Adj. "L" Bracket 85-145mm White
---
EA
6
53
Description
Vertilux CELTIC II - Technical Catalogue
Qty
Unit
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
DASHTRACK FOR SLIDING PANELS
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Vertilux Dashtrack System
3
3 8
4 10
1
8
6
4
7
System for Sliding Panel Individual Components Itemized
57
No.
Item NO.
Description
1
6-700-DM-00001
Vertilux Drapery Motor 1Nm/80rpm/24Vdc/65W
1
EA
2
6-700-DM-00002
Vertilux Drapery Motors - 24V Transformer
1
EA
3
6-700-DM-00003
Vertilux Drapery Motors - Main Control End
1
EA
4
6-700-DM-00004
Vertilux Drapery Motors - Secondary Control End
1
EA
5
6-700-DM-00005
Vertilux Drapery Motors - Interior Belt
---
FT
6
6-700-DM-00008
Vertilux Drapery Motors - Pinch Plead Master Carrier
---
EA
7
6-700-DM-00009
Vertilux Drapery Motors - Curtain Track - White 19'
---
FT
8
6-700-DM-00010
Vertilux Drapery Motors - Ceiling Clip
---
EA
9
6-700-DM-00011
Vertilux Drapery Motors - Plastic Clip
---
EA
10
0-030-CA-06600
Vertilux-Adj. "L" Bracket 85-145mm White
---
EA
Vertilux CELTIC II - Technical Catalogue
Qty
Unit
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
REMOTE CONTROLS FOR VERTILUX CELTIC II MOTORS
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Remote Controls for Vertilux Celtic II Motors
One Channel Remote Item No.: 6-700-AT-CRT01 Controls one single motor Programs in less tan 10 seconds Dimensions: 2” x 5” Frequency: 433.92 Mhz Distance 50’ with obstructions, 150’ line of site Portable Control
Six Channel Remote Item No.: 6-700-AT-CRT06 Controls 5 Motors individually and the 6th Chanel controls all 5 motors simultaneously Programs in less tan 10 seconds Dimensions: 2” x 5” Frequency: 433.92 Mhz Distance 50’ with obstructions, 150’ line of site Portable Control
61
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II -
Remote Controls for Vertilux Celtic II Motors
Sixteen Channel Remote Item No.: 6-700-AT-CRT16 Controls 15 motors individually and the 16th chanel controls all 15 motors simultaneously Programs in less tan 10 seconds Dimensions: 2” x 5” Frequency: 433.92 Mhz Distance 50’ with obstructions, 150’ line of site Portable Control
Wireless 1 Channel Wall Switch Item No.: 6-700-AT-CTW01 Controls one single motor Programs in less tan 10 seconds Dimensions: 3” x 5” Frequency: 433.92 Mhz Distance 50’ with obstructions, 150’ line of site Wall Fixture Control
63
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - Remote for Vertilux Celtic II Motors
Wireless 6 Channel Wall Switch Item No.: 6-700-AT-CTW06 Controls 5 motors individually and the 6th chanel controls all 5 motors simultaneously Programs in less tan 10 seconds Dimensions: 3” x 5” Frequency: 433.92 Mhz Distance 50’ with obstructions, 150’ line of site Wall Fixture Control
Antenna RS232 Item No.: 6-700-AT-RS232 Home Automation Interface Can daisy-chain (5) AC117-01 together Multi-programmable operation Dimensions: 8” x 6” Frequency: 433.92 Mhz Distance 100’ Radious
65
Vertilux CELTIC II - Technical Catalogue
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
REMOTE CONTROLS FRUSTATION FREE PROGRAMMING INSTRUCTIONS
CHANNEL DOWN
STOP
Vertilux CELTIC II - Technical Catalogue
TRANSMISOR CELTIC II FRONT VIEW
CHANNEL UP
DOWN
UP
CELTIC II - Remote Programming
TRANSMISOR CELTIC II BACK VIEW
BATTERY SCREW
PROGRAM
Change Direction of Motor
1
2
Set UPPER Limit
Set LOWER Limit
3
4
FUNCTION PROGRAMMABLEFUNCTION
Communicate Transmitter with Motor
FUNCTION PROGRAMMABLEFUNCTION
The motor will oscillate again -
b) Then press and hold the DOWN button on the remote c) Verify correct rotation
Vertilux CELTIC II - Technical Catalogue
The motor will oscillate. The lower limit is now set
The motor wil oscillate. This will put the motor in PROGRAM mode
a) Move the shade down away from the upper limit previously set, press the PROGRAM button b) Now move the shade up to the desired location of the lower limit and press the PROGRAM button again
The motor will oscillate. The upper limit is now set
b) Now move the shade up to the desired location and press the PROGRAM button again
a) Move the shade 3 to 4� below the upper limit The motor will oscillate This will put the motor in PROGRAM mode position press the PROGRAM button, Located on NOTE: The first limit (UPPER LIMIT) cannot be erased the back of the remote
STEPS NEEDED / TRANSMITTER BUTTONS
NOTES
The motor will oscillate
a) To change motor rotation press and hold the STOP button on the remote.
SETTING LIMITS
The motor will oscillate again. At this time the motor and remote have been joined
NOTES
b) Immediately press and hold the UP button on the remote
a) Press the PROGRAM button on the head of the The motor will oscillate motor
STEPS NEEDED / TRANSMITTER BUTTONS
COMMON FUNCTIONS
You must follow these instructions in the same order they appear on this sheet otherwise the commands will not be able to be done
CELTIC II - Electronic Battery Motor Progamming Instructions
Setting Intermediates Stops (UP to 5)
Delete Memory
Connect an extra Trasmitter
Erasing limits
PROGRAMMABLE FUNCTION
5
FUNCTION PROGRAMMABLEFUNCTION
NOTES
The motor will oscillate. The program instruction have now been copied to the new remote
The motor will oscillate
Vertilux CELTIC II - Technical Catalogue
a) Press and hold the PROGRAM button on the head of the motor for 7 seconds, (the motor will oscillate) The memory has been erased from the motor keep holding the button another 5 seconds. (the motor will oscillate two more times).
b) Immediately press the UP button on the remote you wish to add again.
a) Press and hold the STOP button on the Remote already programed for approximately 5 second
a) Move the shade to the limit you wish to erase. Press and hold the PROGRAM button for approximately 7 The motor will oscillate twice, at this time the limit has been erased seconds
STEPS NEEDED / TRANSMITTER BUTTONS
NOTES
The motor will oscillate. The intermediate limit is now set
The motor will oscillate
LESS COMMON FUNCTIONS
b) Now move the shade to the desired location of the intermediate Stop and press the PROGRAM button again
a) Move the shade away from the previously set limit, about 6 inches, press the PROGRAM button
STEPS NEEDED / TRANSMITTER BUTTONS
SETTING Intermediates LIMITS
You must follow these instructions in the same order they appear on this sheet otherwise the commands will not be able to be done
CELTIC II - Electronic Battery Motor Progamming Instructions
Change Direction of Motor
2
Delete Memory*
Change to Jog Mode and Vice Versa**
4
5
Three short 'beeps'
If direction is the opposite than the one desired, then repeat step using the DOWN button instead
b) Press UP button
Three short ‘beeps’
Hold this button until motor emits sound Hold this button until motor emits sound Within the five beeps Hold this button until motor emits sound Within the five beeps
b) On new transmitter, press & hold: UP a) Press the STOP button b) Press the PROGRAM button a) Press the STOP button b) Press the STOP button again
Three short ‘beeps’
Five short ‘beeps’
Three short ‘beeps’
Five short ‘beeps’
Five short 'beeps'
a) On an already programmed transmitter, press & Hold this button until motor emits sound hold: STOP
STEPS NEEDED / TRANSMITTER BUTTONS
SOUNDS EMITTED BY MOTOR
Five short 'beeps'
Hold this button until motor emits sound
a) Hold the STOP button
NOTES
Three short 'beeps'
Within the five beeps you must release the UP button and press it again once
c) Press the UP button (Within the five beeps)
LESS COMMON FUNCTIONS
Five short 'beeps'
-
SOUNDS EMITTED BY MOTOR
Connect motor while pressing the UP button
-
NOTES
b) Press the UP for 2 seconds & Connect Motor
a) Disconnect the motor
STEPS NEEDED / TRANSMITTER BUTTONS
Vertilux CELTIC II - Technical Catalogue
* This is convenient when there has been a programming mistake and starting the whole programming is needed. ** “Jog Mode” makes the motor make a short movement when pressing the up or down buttons. When in this mode, to make the motor move continually, the up or down button must be pressed for 3 seconds. The “jog mode” is convenient for venetian blinds (wood aluminum) since it allows tilting the slats in a more precise way.
Connect an extra Transmitter
3
FUNCTION PROGRAMMABLE FUNCTION
Communicate Transmitter with Motor
1
FUNCTION PROGRAMMABLE FUNCTION
COMMON FUNCTIONS
CELTIC II - RF & Quiet Motors Basic Progamming Instructions
Change Direction of Motor*
2
Set LOWER Limit
Set UPPER Limit
3
4
FUNCTION PROGRAMMABLE FUNCTION
Communicate Transmitter with Motor
1
If motor goes DOWN follow the step “b”, if it goes UP, please continue to STEP 3
a) Press the UP button
The motor will go UP continuously
b) Press UP & STOP at the same time
Vertilux CELTIC II - Technical Catalogue
Press it continuously until the motor moves back & forth. Your upper limit has been set
The motor will move back & forth (this is done to let the shade know that it is changing direction)
a) Press the PROGRAM button
When you have the exact position, press the STOP button again
Press it continuously until the motor moves back & forth. Your lower limit has been set
c) When you have the exact position, press the STOP button again
If not at the expected position, press the UP or the DOWN button to adjust the limit
If not at the expected position, press the UP or the DOWN button to adjust the limit
b) When you get to the expected position, press the STOP button
c) When you have the exact position, press the STOP button
The motor will go DOWN continuously
NOTES
a) Press DOWN & STOP at the same time
STEPS NEEDED / TRANSMITTER BUTTONS
SETTING LIMITS
-
Press it continuously until the motor moves back & forth
d) Press the PROGRAM button
c) Disconnect the motor
Press it until the motor moves back & forth
c) Press UP & DOWN at the same time
Press it until the motor moves back & forth
-
b) Connect the motor
b) Press the STOP button for 2 seconds
-
NOTES
a) Disconnect the motor for 10 seconds
FUNCTION PROGRAMMABLE FUNCTION STEPS NEEDED /TRANSMITTER BUTTONS
COMMON FUNCTIONS
You must follow these instructions in the same order they appear on this sheet otherwise the commands will not be able to be done
CELTIC II - Electronic Motors Basic Progamming Instructions
Adjusting the Limits** -
Press it until the motor goes back & forth
c) Press the UP or the DOWN button to adjust the limit d) Press STOP
Press it until the motor moves back & forth Press it until the motor moves back & forth again
Connect the motor Press both UP & DOWN at the same time Press PROGRAM button for 10 to 12 seconds
The motor will move back & forth
Disconnect the motor for 10 seconds
Press the PROGRAM button
On the second transmitter, press both UP & DOWN buttons at the same time
STEPS NEEDED / TRANSMITTER BUTTONS
The motor will move back & forth
Press it until the motor moves back & forth
b) Press UP & DOWN at the same time
LESS COMMON FUNCTIONS
If you notice that you need to adjust the limits, follow next steps
NOTES
a) Press all the way UP or al the way DOWN
STEPS NEEDED / TRANSMITTER BUTTONS
Vertilux CELTIC II - Technical Catalogue
* After programming check the direction, if direction is reversed, change it as indicated. If the direction is correct; continue with second programming step. Changing directing can only be done before setting the limits; also it can only be done once. If you need to do it again, you would have to delete and start all over. The motor’s polarity is set for the motor to be on the left by default. If the motor is on the right you must change the direction first ** This step is usually done at the installation site. After setting the limit positions, if the limit is a little off at installation site, then you can do this step. *** This is convenient when there has been a programming mistake and starting the whole programming is needed. Note: You must follow these instructions in the same order they appear on this sheet otherwise the commands will not be able to be done. You MUST erase and start over each time you make a mistake in the programming.
Delete Memory***
Connect an extra Transmitter
PROGRAMMABLE FUNCTION
5
FUNCTION PROGRAMMABLE FUNCTION
Setting limits
CELTIC II - Electronic Motors Basic Progamming Instructions
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
RS232 PROGRAMMING INSTRUCTIONS
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK
CELTIC II - RS232 to RF Programming Instructions Computer Controlled Radio Transmitter Manual 1- Specifications • Extendable antenna • Can daisy-chain (5) AC117-01 together • Multi-programmable operation • SMT machine assembly, damp proof enclosure
2. Parameters Model no.
AC117-01
3. Wiring
Rated voltage workingtemp WorkingCurrent loading power frequency channelno. operationmode (Optional) 230VAC 50Hz 120VAC 60Hz
0°C ≈ +70°C
≤ 20mA
Program button Group control DOWN button Group control STOP button Group control UP button
≤ 20mW
433.92MHz
15 channel
Computer Control/ manual
Antenna
Computer COM interface
RJ11
RJ11
AC POWER
AC POWER
AC POWER
Connect computers
4. Download and Install 1. Install AccessPort software from Performance Concepts webpage or CD-ROM o Run AccessPort.exe o Or extract AccessPort.rar to your desktop using WinRar then run AccessPort.exe 2. Connect laptop to AC117 by first connecting USB-to-Serial adapter to Serialto- RJ-11 adapter 3. Provide 110VAC power to AC117 and Red LED will indicate that the device is powered up.
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
77
Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Integration Device 5. OPTIONS SETTING
2
1
3 5
6
4
7
8
UP
Fill control code in the textbox (Please reference UP code in the right control code list) Click on “Send”.
STOP
Fill control code in the textbox (Please reference STOP code in the right control code list) Click on “Send”.
DOWN
Fill control code in the textbox (Please reference DOWN code in the right control code list) Click on “Send “. Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
78
Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Integration Device After the shades and draperies have been installed and are working as you want them to with the correct channels on the various keypads/transmitters, reference these instructions so that you can pair the RS232-RF device to the shades and draperies:
Pairing the RS232-RF Device to a Roller Shade utilizing a laptop PC 1. Determine the UP control code channel you will use (e.g. FF 10 11 07 DD) and type that into the lower text box so that it is ready for you to click the SEND button • •
CAUTION – Never assign the group control FF 10 11 00 DD in this step as doing so will prevent you from creating sub-groups. The commands FF 10 11 00 DD, FF 10 11 00 CC, and FF 10 11 00 EE should only be used as master override channels (after pairing has been completed) and are never utilized during the pairing step.
2. Press and hold STOP button of the existing transmitter or keypad until you hear 5 beeps 3. During the 5 beeps, send the correct UP control code (e.g. FF 10 11 07 DD) by clicking SEND 4. If the RS232-RF signal was received by the roller shade motor, you will hear 3 beeps. 5. Ensure that the RS232-RF device is working by sending UP, STOP, and DOWN control codes. If the device is not working properly, start over.
1
3
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
79
Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 to RF Integration Device Pairing the RS232-RF Device to a Drapery Track utilizing a laptop PC 1. Determine the STOP control code channel you will use (e.g. FF 10 11 09 CC) and type that into the lower text box so that it is ready for you to click the SEND button 2. Press and hold STOP the PROGRAMMING button on bottom of motor until the RED LED flashes 3. While the RED LED is flashing, send the correct STOP control code (e.g. FF 10 11 09 CC) and within 5 seconds, SEND the correct UP control code (e.g. FF 10 11 09 DD) by changing the last two letters of the string from CC to DD.
1
3
4. Ensure that the RS232-RF device is working by sending UP, STOP, and DOWN control codes. If the device is not working properly, start over.
Note: Crestron requires a \x before each two digits of the string commands, i.e. \xFF\x10\x11\x00\xDD
80
Vertilux CELTIC II - Technical Catalogue
CELTIC II - RS232 Interface Programming Codes RS232 Interface Programming Codes UP Control Codes:
81
STOP Control Codes:
DOWN Control Codes:
GROUP CONTROL
FF 10 11 00 DD
GROUP CONTROL
FF 10 11 00 CC
GROUP CONTROL
FF 10 11 00 EE
1ST GROUP
FF 10 11 01 DD
1ST GROUP
FF 10 11 01 CC
1ST GROUP
FF 10 11 01 EE
2ND GROUP
FF 10 11 02 DD
2ND GROUP
FF 10 11 02 CC
2ND GROUP
FF 10 11 02 EE
3rd GROUP
FF 10 11 03 DD
3rd GROUP
FF 10 11 03 CC
3rd GROUP
FF 10 11 03 EE
4th GROUP
FF 10 11 04 DD
4th GROUP
FF 10 11 04 CC
4th GROUP
FF 10 11 04 EE
5th GROUP
FF 10 11 05 DD
5th GROUP
FF 10 11 05 CC
5th GROUP
FF 10 11 05 EE
6th GROUP
FF 10 11 06 DD
6th GROUP
FF 10 11 06 CC
6th GROUP
FF 10 11 06 EE
7th GROUP
FF 10 11 07 DD
7th GROUP
FF 10 11 07 CC
7th GROUP
FF 10 11 07 EE
8th GROUP
FF 10 11 08 DD
8th GROUP
FF 10 11 08 CC
8th GROUP
FF 10 11 08 EE
9th GROUP
FF 10 11 09 DD
9th GROUP
FF 10 11 09 CC
9th GROUP
FF 10 11 09 EE
10th GROUP
FF 10 11 0A DD
10th GROUP
FF 10 11 0A CC
10th GROUP
FF 10 11 0A EE
11th GROUP
FF 10 11 0B DD
11th GROUP
FF 10 11 0B CC
11th GROUP
FF 10 11 0B EE
12th GROUP
FF 10 11 0C DD
12th GROUP
FF 10 11 0C CC
12th GROUP
FF 10 11 0C EE
13th GROUP
FF 10 11 0D DD
13th GROUP
FF 10 11 0D CC
13th GROUP
FF 10 11 0D EE
14th GROUP
FF 10 11 0E DD
14th GROUP
FF 10 11 0E CC
14th GROUP
FF 10 11 0E EE
15th GROUP
FF 10 11 0F DD
15th GROUP
FF 10 11 0F CC
15th GROUP
FF 10 11 0F EE
Vertilux CELTIC II - Technical Catalogue
VERTILUX, Ltd. H e adq uar t e rs : 7300 NW 3 5 t h Ter race, Mi ami , Fl , 3 312 2 Phone : 1. 800. 3 5 6 .8 8 37 - Fax : 1.8 0 0 .27 5 .1719
w w w.ve r tilux.com
AUTHORIZED DISTRIBUTOR:
MIAMI
. D A L L A S . L O S A N G E L E S