VILLEGAS RESIDENCE This Project is one of my very first Drafting Design projects I acquired when starting to provide drafting service. It consisted of taking off the original Gable type roof over the house and a flat roof over the Garage. I designed a second story to go over the first floor consisting of 4 Bedrooms and 2 Baths. The first floor received a Kitchen remodel, the demo of a few walls for an open floor plan and staircase access. A new roof to match was placed over the garage area. The Project was built.

VICENTE REYES

VILLEGAS


VICENTE REYES

VILLEGAS


VICENTE REYES

VILLEGAS


GRACIES MARKET This is an example of light commercial work I have completed to acquire permits and clearances for new Tenant and Services for a Retail Establishment.

VICENTE REYES

GRACIES MARKET


Sill 7'-6"

Sill 7'-6"

2'-6" X 6'-8"

3'-0" 2'-0"

5

3'-0" 2'-0"

8

WALL A/C

D

(E)JANITORIAL ROOM

(E)RESTROOM

ALL ELECTRICAL EXISTING IN THIS AREA

6

ADJACENT UNIT

7 B A

A

ALL ELECTRICAL EXISTING IN THIS AREA

3'-0" X 7'-0"

A

E

4'-8" X 7'-0"

ALL ELECTRICAL EXISTING IN THIS AREA A

3

4

4'-0" X 6'-8"

954 MISSION

956 MISSION

REFRIGERATOR MERCH. / MODEL NO. TGM-48R

3

FREEZER MERCH. / MODEL NO. TGF-49F

4

OPEN DISPLAY MERCH. / MODEL NO. TOM-50

5

3 COMPARTMENT SINK / TSA-3-14-D1 (18"X18"X14" BOWLS) w/ 18" DRAIN BOARDS EA. SIDE

6

COFFE & TEA MAKING AREA

7

BACK-UP DRY FOOD STORAGE SHELVES N.S.F.

8

BACK-UP DRY FOOD STORAGE SHELF N.S.F.

VR DRAFTING RESIDENTIAL DRAFTING • DESIGN 134 N. MYRTLE AVE., #C MONROVIA, CA 91016 PH.626.823.9578 • vr_drafting@yahoo.com

CONSULTANTS

GRACIE'S MARKET

954

956

FURNITURE LIST

C

4'-0" X 6'-8"

2

MISSION STREET

A

2

REFRIGERATOR MERCH. / MODEL NO. TGM-69R

NOTE: 1. ALL EQUIPMENT TO CONFORM BY ANSI STANDARDS 2. ALL EQUIPMENT TURBO AIR - UL/NSF RATED OR EQUIVALENT AS PER CODE REQUIREMENT

ADJACENT UNIT

(E)STORAGE

2'-6" X 6'-8"

1

N

1

MERIDIAN AVENUE

EQUIPMENT LIST WALL A/C

SITE MAP

A

METRO SHELF (48"L X 18"D X 72"H)

B

METRO HEAVY DUTY SHELF CART (33.75"L X 18"D X 32.25"H) FOR COFFE & TEA SLEF SERVE AREA

C

BOOK SHELF (68.5"L X 19.25"D X 72"H)

D

MAGAZINE RACK (32"W X 32"D X 72"H)

E

CASH & WRAP COUNTER

LIGHTING LEGEND LIGHT FIXTURE

PROJECT ADDRESS:

GRACIE'S MARKET

VENT & LIGHT (120 C.F.M.) LIGHT SWITCH

EQUIPMENT & LIGHTING PLAN SCALE: 1/4" =

1'-0"

CEILING FAN

TRACK LIGHT

954 & 956 Mission St. Los Angeles, CA #Post

1

11

WALL A/C

7

3'-0" 2'-0"

3'-0" 2'-0"

WALL A/C

P 2

C 1

B 2

BASE =

B 2

BASE =

4" WOOD BASE (PAINTED)

B 3

BASE =

SLIMFOOT COVE BASE DAL TILE

SLIMFOOT COVE BASE 4"

14'-2"

2'-0"

ALL ELECTRICAL EXISTING IN THIS AREA

5'-5" 7'-10"

2'-4"

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.

FIXED WINDOW DOOR ACTIVATED AIR CURTAIN SELF CLOSING DOOR SHELF CLEANING SUPPLY SHELF HANDSINK 13x11x5 N.S.F. HOT WATER HEATER (30 GAL. 4500 KW) TANKLES WATER HEATER (4 GAL. 1500 KW) UNDER SINK MOP SINK 18x18x12 (FREE STANDING) N.S.F. APPROVED BACKFLOW PREVENTION DEVICE AT FAUCET EMPLOYEE LOCKERS MOP & BROOM HANGER SELF CLOSING HINGES 8'-0" HIGH WALL

/ / MARK

DATE

DESCRIPTION

PROJECT NO: 216.003 DRAWN BY: Vicente J. Reyes

16'-2" 12'-2" 4'-0" X 6'-8"

DATE: 1/9/08

3

16'-2"

TILE FLOORING 4'-0" X 6'-8"

2'-6" X 6'-8"

ALL ELECTRICAL EXISTING IN THIS AREA

3'-0" X 7'-0"

13

2'-6" X 6'-8"

1'-0"

14'-10"

6

16'-2"

SMOOTH CONCRETE FLOORING

KEYNOTES:

15'-2"

ADJACENT UNIT

B 1

5'-11 1/2"

4'-0"

WALL PAINT = SEMI-GLOSS, SMOOTH FINISH LIGHT TAN CEILING PAINT = SEMI-GLOSS, SMOOTH FINISH WHITE

Maggie Kilbourne

8

5'-7"

(E)STORAGE

B 2

C 1

(E)RESTROOM

3'-4"

10'-7"

21'-0 1/2"

4'-8" X 7'-0"

C 1

P 2

4 10

WALL PAINT = SEMI-GLOSS, SMOOTH FINISH WHITE

4'-8" X 7'-0"

P 2

3'-0" X 7'-0"

P 1 C 1

P 1

12

9

ALL ELECTRICAL EXISTING IN THIS AREA

FINISH LEGEND

7'-0"

B 1

2'-6" X 6'-8"

C 1

C 1

Sill 7'-6"

5 (E)JANITORIAL ROOM

11'-0"

B 1

P 1 B 1

15'-7 1/2"

2'-6" X 6'-8"

Sill 7'-6"

ADJACENT UNIT

C 1

27'-0"

3'-0" 2'-0"

3'-0" 2'-0"

OWNER: Sill 7'-6"

P 2

Sill 7'-6"

P 2

PH: 626.441.4111

1

SHEET TITLE

2

4'-0" X 6'-8"

FLOOR PLAN

4'-0" X 6'-8"

1

1

954 MISSION

1

1

1

956 MISSION

1

1

1

FLOOR PLAN FINISH PLAN SCALE: 1/4" =

SCALE: 1/4" =

1'-0"

1'-0"

A-01

VICENTE REYES

GRACIES MARKET


SP-CHILDREN’S MEMORIAL & HEALING GARDEN This is a project that was brought to my attention by a contractor associate. He asked if I was interested in donating my time and expertise and put together the construction documents for a Healing Garden in South Pasadena. My duties were to take the already created landscape design and layout workable plans. I laid out the plans with dimensions and added details like the arches and concrete benches. Please visit the website, I am included on the sponsors page. http://sphealinggarden.org

VICENTE REYES

SP-HEALING GARDEN


CHILDREN'S MEMORIAL GARDEN, AT GARFIELD PARK, SOUTH PASADENA

LEGEND

REVISIONS

#1 HEUCHERA 'OPAL' (OPAL CORAL BELLS) #2 DIETES GRANDIFLORA 'VARIEGATA' (VARIEGATED FORNIGHT LILY) ENGRAVED BOULDERS 5

#3 ROSEMARIUS 'KEN TAYLOR' (KEN TAYLOR ROSEMARY)

4

DG w/STABILIZER

4

STONE PAVERS (SOME WILL BE ENGRAVED)

0"

1

3'-

3

#4 COLEONEMA PULCHELLUM 'SUNSET GOLD' (SUNSET GOLD BREATH OF HEAVEN)

4 5

TXT

DIETES GRANDIFLORA 'VARIEGATA' (VARIEGATED FORNIGHT LILY)

N

PITTOSPORUM TENUFOLIUM 'MARJORIE CHANNON'

1

1

MIX OF LOW-GROWING SEDUMS: SEDUM TRICOLOR, SEDUM ANGELINA, SEDUM REFLEXUM

HEUCHERA 'OPAL' (OPAL CORAL BELLS) 4 01 A-01

ROSEMARIUS 'KEN TAYLOR' (KEN TAYLOR ROSEMARY)

5

#5

OWNER:

PITTOSPORUM TENUFOLIUM 'MARJORIE CHANNON'

KRIS CALVIN & MIEKE KRAMER

01 A-01

MISSION ST. & PARK AVE. SOUTH PASADENA, CA, 91030

STAINED CONCRETE w/ 1/4" AGGREGATE

MIEKE PHONE: 323.854.7599 KRIS PHONE: 626.825.7444

2

GATHERING AREA 02 A-01

EXISTING CONCRETE WALK

EXISTING CONCRETE WALK

01 A-01

1

3/4" PEBBLE

EXISTING CALLESTEMON VILMINALIS (TYP) (WEEPING BOTTLEBRUSH)

EXISTING CALLESTEMON VILMINALIS (TYP) (WEEPING BOTTLEBRUSH)

3

1

COLEONEMA PULCHELLUM 'SUNSET GOLD' (SUNSET GOLD BREATH OF HEAVEN)

3

1/4" AGGREGATE

OLD BRICK

DIETES GRANDIFLORA 'VARIEGATA' (VARIEGATED FORNIGHT LILY)

STAINED CONCRETE BENCH (TYP.)

NASSELLA TENUISSIMA (MEXICAN FEATHER GRASS)

NASSELLA TENUISSIMA (MEXICAN FEATHER GRASS)

LANDSCAPE PLAN SCALE: 1/8" =

SCULPTURE

1'-0"

PATHLIGHTS UPLIGHTS

BOULDER SCHEDULE RK

STRATFORD AVE.

GREVELIA ST.

AREA WHERE WORK IS TO BE PERFORMED

.

PL

A CL

1

30"x30" BOULDER

2

2'x2' BOULDER

3

3'x3' BOULDER

4

4'x4' BOULDER

5

5'x5' BOULDER

GARFIELD PARK

3'-0"

4'-0"

DRAFTSMAN: #CAD Technician

626-823-9578

1 1/2" PIPE

1/2" SIMPSON RFB#4x6 (TYP) 4 @ EA. PLATE

1'-6"

6"

2"

TITLE & SITE PLAN

2"

PROJ. # #Pln

6"

1" PIPE

8'-0"

1 1/2" PIPE

12"

1'-6"

DATE: 10/17/07

03 A-01

12"

1'-2"

POURED IN PLACE CONC. BENCH & CAP

SCALE: AS SHOWN SHEET:

STAINED CONC. SLAB

PLAN VIEW

STAINED CONC. SLAB

12"

A-01

VICINITY MAP 03

VICENTE REYES

02

01

SP-HEALING GARDEN


R 21'-4 1/2"

TXT

3'-

0"

REVISIONS

34'-8 1/2"

OWNER:

KRIS CALVIN & MIEKE KRAMER MISSION ST. & PARK AVE. SOUTH PASADENA, CA, 91030 MIEKE PHONE: 323.854.7599

23'-6 1/2" 12'-0"

7'-8"

18"

1/2"

/2"

71

3'-

10'-3

11'-6"

17'-9 1/2"

12'-7 1/2"

10'-3"

14'-1"

7'-3"

KRIS PHONE: 626.825.7444

9'-7"

8'-10"

4'-

18

9'-3"

9'-2 1/2"

4'-11"

2'-11"

4'-0"

18"

"

6"

10'-0"

6'-5"

18'-6"

'-2

5'-0"

0"

18'-3"

2'-4"

18"

18

"

2'-4 1/2"

1'-10"

6'-

24"

R 1'-10"

"

12"

5'-0"

13'-8"

R5

DRAFTSMAN: #CAD Technician

626-823-9578

Layout

19'-9" 22'-11 1/2"

PROJ. # #Pln DATE: 10/17/07 SCALE: AS SHOWN SHEET:

DIMENSIONED PLAN SCALE: 1/2" =

1'-0"

VICENTE REYES

A-02

SP-HEALING GARDEN


MONTIJO RESIDENCE This project is a remodel and addition to a single family dwelling. The customer wanted to change the complete look of the house to a Spanish Mediterranean style. The house was a two bedroom home, but one bedroom was too small. I added one new full bedroom, a master bedroom and a great room with a higher ceiling. Making it a three bedroom house. The plan was submitted and laid out as Type ‘V.’ Due to the complexity of the roof, I utilized a Structural Engineer to oversee and produce calculations. This project was built. This Project was Built.

VICENTE REYES

MONTIJO

RESIDENCE


05

03 04

DEMO PLAN EXISTING FLOOR PLAN

SCALE: 1/4" = SCALE: 1/4" =

1'-0"

VICENTE REYES (E) LIVING ROOM

17'-3"

(E) CASED ARCHWAY

(E) CASED ARCHWAY

ARCHWAY

(E) CASED ARCHWAY

ARCHWAY

(E) ENTRY FOYER (E) CASED

5'0"x6'8" 2'8"x6'8"

TYPICAL DEMO WALL

3'6"x3'0" 2'6"x6'8" (E) CLOSET

(E) COVERED PATIO

(E) CASED

4'0"x3'0"

(E) GARAGE

(E) KITCHEN

8'0"x6'0"

03

1'-0"

MONTIJO

508 S ASTELL AVE WEST COVINA, CA 91790 Tel: 1.626.484.4600

3'0"x4'0"

Chuck & Delores Montijo

20'-11" This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

DISCLAIMER NOTICE

56'-5"

NEW FAMILY ROOM, MASTER BED & BATH ADDITION

16'-7"

10'-10"

22'-2"

2'6"x3'0"

15'-3"

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

BY REVISIONS DATE

3'0"x6'8" 16'0"x7'0"

Date: 2/2/12

Scale:

Drawn:

AS NOTED

39'-2" Job:

Plotted On:

335.001

Sheet

A1.04 2/2/12

EXISTING FLOOR & DEMO PLAN

ARCHWAY

(E) BATH

ARCHWAY

5'0"x6'8"

(E) CASED

2'8"x6'8"

(E) HALLWAY

(E) BEDROOM

(E) CASED

2'6"x6'8"

3'6"x3'0"

11'-1"

3'0"x4'0"

(E) HALLWAY

(E) CASED OPENING

4'0"x4'6"

44'-9"

NEW DOOR/ CASED OPENING (TYPICAL)

6'-0"

4'0"x4'6"

33'-8"

10

9'-5"

(E) BEDROOM

1" ACTUAL

RESIDENCE

E: T: M: W:

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

VICENTE J. REYES

VR DRAFTING


STORM WATER POLLUTION CONTROL REQUIREMENTS:

01

2'-0"

-1.5"

4'-0" 01

01

7'-4"

14'-0"

6'-8"

11'-4"

15'-2"

05

2'-6" (E) HALLWAY

A A1.09

e. Excess or waste concrete may not be washed into the public way or any other drainage system. Provisions shall be made to retain concrete wastes on site until they can be disposed of as solid waste.

1.09 FIREPLACE (CONSTRUCTION AND INSTALLATION PER MFR. SPECS.) CODE APPROVED.

1.08 TEMPERED GLASS DOOR AND PANEL @ SHOWER

27'-7"

GENERAL PLAN NOTES:

g. Sediments and other materials may not be tracked from the site by vehicle traffic. The construction entrance roadways must be stabilized so as to inhibit sediments from being deposited into the public way. Accidental depositions must be swept up immediately and may not be washed down by rain or other means.

1.

h. Any slopes with disturbed soils or denuded of vegetation must be stabilized so as to inhibit erosion by wind and water.

2.

BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWER HEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE FLOOR (R307.2) SHOWER DOORS SHALL SWING OUT. NET AREA OF SHOWER RECEPTOR SHALL BE NOT LESS THAN 1,024 SQ.IN. OF FLOOR AREA, AND ENCOMPASS 30IN. DIAMETER CIRCLE. (PC 411.7) CLOTHES DRYER MOISTURE EXHAUST DUCT MUST BE 4-IN. IN DIAMETER AND LENGTH IS LIMITED TO 14-FT w/2 ELBOWS. THE DUCT LENGTH SHALL BE REDUCED BY 2FT FOR EVERY ELBOW IN EXCESS OF TWO. THE BUILDING SHALL HAVE WATER CLOSETS (TOILETS), WHICH USE NO MORE THAN 1.6 GALLONS PER FLUSH. ALL SHOWER AND TUB-SHOWERS SHALL HAVE A PRESSURE BALANCE, THERMOSTATIC MIXING VALVE, OR A COMBINATION PRESSURE BALANCE/ THERMOSTATIC MIXING TYPE VALVE. ALL NEW, REPLACEMENT AND EXISTING WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN THE 1/3 LOWER OF THE TANK. THE LOWER POINT SHALL BE A MINIMUM OF 4-IN. ABOVE THE CONTROLS.

3.

2'-6"

10

1'-10" 1'-6"

(E) FAU IN ATTIC (APROX. LOC.)

(E) BEDROOM

4'-0"

20"x30" ATTIC ACCESS

02

3'-8"

3'-0"

4'-6"

1.07 NEW RINNAI TANKLESS WATER HEATER. INSTALLED BY OTHER PER MFR. SPECS.

BROOM CLOSET 4.

55'-10"

03

1'-6" 1'-10"

25'-7"

01

2'-4" 5'-9"

4'-2"

HIS CLOSET

HER CLOSET

1.06 RELOCATED POWER METER.

d. Non-stormwater runoff from equipment and vehicle washing and any other activity shall be contained at the project site.

1.05 HARD WIRED SMOKE DETECTOR w/BATTERY BACKUP (MAY BE BATTERY IN EXISTING DWELLING) TYPICAL FOR SD SYMBOL.

5'-1"

3'-0"

B A1.09

1.04 30" x 30" ATTIC ACCESS

c. Fuels, oils, solvents and other toxic materials must be stored in accordance with their listing and are not to contaminate the soil and surface waters. All approved storage containers are to be protected from the weather. Spills must be cleaned up immediately and disposed of in a proper manner. Spills may not be washed into the drainage system.

f. Trash and construction related solid wastes must be deposited into a covered receptacle to prevent contamination of rainwater and dispersal by wind.

F.F.=0'-0"

1'-3"

07

3'-3"

20"x30" 09 ATTIC ACCESS

10

5'-9" 2'-10"

-1.5"

7'-0"

(N) GREAT ROOM

B A1.09

CLOSET 6'-1"

6'-7"

01

3'-0"

19'-10"

4'-4"

08

2'-4"

16" 16"

02

8'-4"

4'-0"

1'-9"

(N) MASTER BATH

2'-3"

02

7'-8" 5'-5"

32"

5'-6"

(N) BEDROOM

12'-5"

12'-2"

13'-8"

01

7'-4"

22'-3"

14'-7"

19'-8"

(N) MASTER BEDROOM

1.02 WALLD TO BE FILLED IN 1.03 7 3/4" MAX RISE, 10" MIN. RUN

b. Stockpiles of earth and other construction related materials must be protected from being transported from the site by the forces of wind or water. 3'-0"

-1.5"

4'-0" 3'-0"

7'-0" 7'-0" 01

1.01 CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 70 INCHES.

a. Eroded sediments and other pollutants must be retained on site and may not be transported from the site via sheet flow, swales, area drains, natural drainage courses or wind.

A A1.09

5.

(E) BATH (N) KITCHEN

6.

30"x30" (E)ATTIC ACCESS

(E) CASED

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

6'-8"

E: T: M: W:

20'-5" 7'-11"

5'-11"

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

5'-8"

VICENTE J. REYES

5'-7"

VR DRAFTING

11'-3" 7'-5"

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

14'-11" 7'-5"

FLOOR PLAN KEYNOTES:

The following represent the minimum standards of good housekeeping that must be implemented on all construction sites.

11'-9"

DISCLAIMER NOTICE

46'-8"

5'-0" 3'-0" 2'-0" 4'-0" 4'-0"

MTL

TYPE

FINISH

GLAZING

NOTES

4'-0" 1'-6" 5'-0" 6'-0" 4'-0"

WINDOW TYPES TYPE

W Sliding2 15

W Sliding2 15

W Arched Cas 15

W Arched Cas 15

W Arched Cas 15

03

04

03

3'-0"

4'0"x8'0"

5'-0"

TEMPERED

4'-0"

6'-0"

5'-0"

ELEVATION

1'-6"

4'-0"

4'0"x8'0"

05

2'-0"

4'-0"

4'-0"

TEMPERED

ID

56'-5"

PROPOSED FLOOR PLAN SCALE: 1/4" =

1'-0"

01

02

03

04

05 1" ACTUAL

* DOOR MARKER

DOOR SCHEDULE MARK QTY W 01 02 03 05 06 07 08 09 10

3 2 1 1 1 1 1 1 2

HT

6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8"

TYPE

PATIO SLDR LH-SWING RH-SWING RH-SWING LH-SWING RH-SWING CLOSET SLDR CLOSET SLDR ---

THK 0'-2" 0'-1" 0'-1" 0'-1" 0'-1" 0'-1" 0'-1" 0'-1" 0'-2"

MATL

BY OWNER BY OWNER BY OWNER BY OWNER BY OWNER BY OWNER BY OWNER BY OWNER -----

EL

GLZ

FIRE RATING

NOTES

BY REVISIONS DATE

---

---

---

Date:

2/2/12

Scale:

AS NOTED

Drawn: 5'-4"

6'-9"

6'-9"

6'-9"

6'-9"

6'-9"

6'-9"

ELEVATION

6'-9"

6'-9"

1'-4"

DOOR TYPES

6'-0" 2'-8" 2'-8" 2'-6" 2'-0" 2'-0" 6'-0" 5'-0" 2'-8"

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

Job:

335.001

Sheet

ID

6'-2"

2'-10"

2'-10"

2'-8"

2'-2"

2'-2"

6'-2"

5'-2"

2'-8"

01

02

03

05

06

07

08

09

10

A1.05 Plotted On:

VICENTE REYES

MONTIJO

2/2/12

FLOOR PLAN | DOOR & WIN SCH.

01 02 03 04 05

508 S ASTELL AVE WEST COVINA, CA 91790 Tel: 1.626.484.4600

WINDOW SCHEDULE MARK W H

Chuck & Delores Montijo

*

NEW FAMILY ROOM, MASTER BED & BATH ADDITION

(E) CASED

ARCHWAY ARCHWAY

(E) CASED

(E) DINING

ARCHWAY

ARCHWAY ARCHWAY

(E) GARAGE

WINDOW MARKER (E) CASED

(E) CASED (E) CASED

(E) ENTRY FOYER

ARCHWAY

(E) CASED

(E) LIVING ROOM

(E) HALLWAY

(E) CASED OPENING

33'-7"

ARCHWAY

RESIDENCE


AFCI

LV

AFCI F

F

HARD WIRED SMOKE DETECTOR w/ BATTERY BACK-UP (MAY BE BATTERY OPERATED IN EXISTING DWELLING)

CO

CARBON MONOXIDE DETECTOR SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP (MAY BE BATTERY OPERATED IN EXISTING DWELLING)

F

FAN & LIGHT COMBO (EXHAUST FAN TO HAVE 5 AIR CHANGES PER HOUR)

AFCI

F

LOW VOLTAGE RECESSED CAN LIGHT

ABBREVIATIONS AFCI D F GFI MD MP WP P&N

EXHAUST FAN TO HAVE 5 AIR CHANGES PER HOUR

F AFCI

DUPLEX OUTLET (AFCI IN ALL SLEEPING AREAS)

AFCI

3

AFCI

AFCI

T

GFI

AFCI F

WP GFI

3. High efficacy lighting system must be operated on a separate switch from any incandescent or other low efficacy lighting system. 4. Recessed luminaries in all insulated ceilings must be approved for zero-clearance insulation cover (IC) and must be airtight. 5. Kitchen lighting, at least 50% of installed wattage must be high efficacy.

ARC FAULT CIRCUIT INTERRUPTER DIMMER FLUORESCENT GROUND FAULT CIRCUIT INTERRUPTER MOTION DETECTION MOISTURE PROOF WEATHER PROOF PHONE & NETWORK

6. Bathroom, laundry, utility room and garage lighting, shall be high efficacy or shall be controlled by a manual-on occupant sensor. 7. All other rooms: (hallways, stairs, dining, living, etc) lighting, shall be high efficacy or shall be controlled by a manual-on occupant sensor or a dimmer. Exception, closets less than 70 square feet. 8. All outdoor lighting attached to the building, shall be high efficacy or controlled by both a motion sensor and photo control.

ELECTRICAL NOTES: ALL ELECTRICAL TO BE INSTALLED PER 2011 CEC

GROUND FAULT INTERRUPTER w/ WEATHER PROOF COVER

AFCI

F

GFCI +44"

GROUND FAULT INTERRUPTER

2. Must have electronic Ballast for lamps rated 15 watts or greater & output frequency no less than 20 Khz.

SD

F

F

F

AFCI

F

F

220v RECEPTACLE OUTLET 3

220 F

F

3 GFCI +44"

*

WP GFCI

COMMUNICATIONS TELEVISION OUTPUT

3

SD

SD

F

1 A1.10 CO

1 A1.10

SD

F

1 A1.10

F

TYP. 4x6 GIRDER

4x6 GIRDER

CO

SD

4x4 POST & HOLDDOWN ABOVE (TYPICAL) 4x6 GIRDER

2 A1.10

ELECTRICAL PLAN SCALE: 1/4" =

18"x24" UNDER FLOOR ACCESS

EXISTING FOOTING TO BE REMOVED

7 A1.10

1'-0" 8 A1.10

B A1.09

7 A1.10 4x6 GIRDER

NEW FOUNDATION

3 A1.10

TYP. @ HIP 16 & WALL A1.10

L= 4'-0"

L= 4'-0"

2x8 C.J. @ 16" O.C. L= 11'-9"

KING POST

KING POST

KING POST 4x10 FLUSH CLNG. BM.

L= 4'-0"

KING POST B A1.09

10' CEILING

4x4 HDR

4x4 HDR

4x4 HDR

B A1.09

1" ACTUAL

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

KING POST

=1/2" STRUCTURAL PLY. w/8d @ 6"/6"/12" O.C.

MST37

A A1.09

12

L= 4'-4" A1.10

11 A1.10 3 1/2" x 11 1/4" MICROLAM BEAM 4x4 POST w/ECC44 CAP STRAPS ROTATED 90 DEGREES

BY REVISIONS DATE

11 A1.10

12 L= 8'-0" A1.10

KING POST 4x10 FLUSH CLNG. BM.

4x4 HDR

4x4 HDR

L= 8'-0"

EXISTING GARAGE FOUNDATION

TYP. @ HIP 14 & RIDGE A1.10

2x8 C.J. @ 16" O.C.

SOLID BLOCKING AT THE ENDS OF EACH FLOOR JOIST & SUPPORTS

MST37

A A1.09

Date:

2/2/12

Scale:

AS NOTED

Drawn: Job:

FRAMING PLAN

FOUNDATION PLAN

SCALE: 1/4" =

SCALE: 1/4" =

1'-0"

FOUNDATION VENT ASSUMED LOCATION (TYPICAL FOR 15)

5 A1.10

4x10 FLUSH CLNG. BM.

4x4 HDR

4x4 HDR MST37

4x6 HDR

4 A1.10

A A1.09

2x8 C.J. @ 16" O.C.

KING POST

12 A1.10

3 A1.10

10 A1.10

4x10 FLUSH CLNG. BM. 4x6 HDR

2x8 C.J. @ 16" O.C.

4x6 GIRDER

10 A1.10

4x10 FLUSH CLNG. BM.

KING POST

12 A1.10 4x4 HDR

4x6 GIRDER

KING POST

2-2x8 C.J.

8' CEILING THROUGHOUT U.O.N.

11 A1.10

15 A1.10

4x6 HDR

4x6 HDR

4x10 FLUSH CLNG. BM.

L= 8'-0"

TYP. @ HIP

4x10 FLUSH CLNG. BM.

A A1.09

9 A1.10

4x6 HDR

2x8 C.J. @ 16" O.C.

KING POST

EXISTING FOUNDATION

9 A1.10

2x6 F.J. @ 16" O.C.

4x6 HDR

20 A1.10

L= 4'-0"

4x6 HDR

4x6 HDR

L= 4'-0"

4x6 HDR

TYP. @ EXIST HOLDDOWN

7 A1.10

2x6 F.J. @ 16" O.C.

5 A1.10 11 A1.10

L= 4'-0"

L= 6'-0"

L= 4'-0"

B A1.09

4x6 GIRDER

4x6 GIRDER

11 A1.10

2 A1.10

7 A1.10

2x6 F.J. @ 16" O.C.

SD

19 A1.10

4x6 GIRDER 2x6 F.J. @ 16" O.C.

7 A1.10

TYP. @ HOLDDOWN

6 A1.10

DISCLAIMER NOTICE

4 A1.10

NEW FAMILY ROOM, MASTER BED & BATH ADDITION

4 A1.10 2 A1.10

ALL ELECTRICAL EXISTING AND UN-ALTERED U.O.N. w/SYMBOL)

2x6 F.J. @ 16" O.C.

AFCI

A1.06

1'-0"

Plotted On:

VICENTE REYES

335.001

Sheet

MONTIJO

2/2/12

FOUNDATION | FRAMING | ELECTRICAL PLANS

RECESSED CAN LIGHT AFCI

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

AFCI

F

E: T: M: W:

F

1. High efficacy lighting, must not contain medium based incandescent sockets except for outdoor high intensity discharge lighting containing HID Ballast, HID rated socket and meeting min. lumens per watt.

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

AFCI

FLORESCENT STRIP FIXTURE

AFCI

VICENTE J. REYES

3 AFCI

Lighting Requirements

508 S ASTELL AVE WEST COVINA, CA 91790 Tel: 1.626.484.4600

WALL MOUNTED LIGHT FIXTURE

Chuck & Delores Montijo

AFCI

CALIFORNIA TITLE-24

SINGLE POLE SWITCH *= 2 = DOUBLE POLE SWITCH *= 3 = 3 WAY SWITCH *= 4 = 4 WAY SWITCH *= D = DIMMER SWITCH *= MD = MOTION DETECTION *= T = TIMMER SWITCH *= WP = WEATHER PROOF SWITCH

VR DRAFTING

WP GFCI AFCI

*

CEILING LIGHT FIXTURE

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

ELECTRICAL LEGEND

RESIDENCE


Detailer for ArchiCAD 13

1 high 1 wide

Notes

ROOF TILE PER PLAN LAP 18" UNDER TILE

ROOF PLAN KEYNOTES:

HOT MOP / EQ. ROOF TILE PER PLAN

2.01 INSTALL 3”H, 24 GA GALVANIZED SM DRIP EDGE FLASHING, TYPICAL AT ALL EAVES AND RAKES

LAP 18" UNDER TILE

2.02 INSTALL 24”W, 24 GA GALVANIZED SM VALLEY FLASHING, TYPICAL AT ALL VALLEYS 2.03 INSTALL 8"H x 6"W, 24 GA GALVANIZED SM 'L' FLASHING, WITH 24 GA GALVANIZED SM 'COUNTERFLASHING', TYPICAL AT ALL ROOF TO WALL INTERSECTIONS.

R.R. (PER PLAN) 1x_ FACIA

H

01 A1.07 (E) SLOPE

2.02

EXISTING ROOF

(E

)V AL

LE

(E) R.R.

2.09

H IP

NEW

IP

IP H IP

H

8

ROOF

8 2x

2x

ATTIC VENTILATION | OVER FAMILY ROOM REQUIRED 1/150 PROPOSED SF = 498 REQUIRED NFAV SF = 3.3 QTY DESC 22 3-2” DIA VENT HOLES EA. OTHER RAFTER 4 MODEL ‘S’ ROOF TILE VENT 0 CJ Metal Half Round Dormer Vents DM30

2x8 R.R. @ 16" O.C.

2x8 R.R. @ 16" O.C. H

CRICKET

PROV. NFAV= 6.6 REQ. NFAV= 6.6 NFAV = NATURAL FREE AIR VENTILATION

8

8 2x

(E) SLOPE

(E) RIDGE BOARD

(E) R.R.

2x

(E) SLOPE

Y

2.03

2x8 R.R. @ 16" O.C.

(E

2x8 R.R. @ 16" O.C.

EY

L AL )V

(E) R.R.

(E) SLOPE

(E) RIDGE BOARD

17 TYP. @ A1.10 THIS ROOF

PROV. NFAV= 4.0 REQ. NFAV= 3.3 NFAV = NATURAL FREE AIR VENTILATION

2.07 2.04 2.05 2.06 4:12 SLOPE THROUGHOUT

ENERGY NOTES: 1.

TOP PLATE SCALE: 1/4" =

CRAWL SPACE VENTILATION REQUIRED 1/150 PROPOSED SF = 984 REQUIRED NFAV SF = 6.6 QTY DESC 14 16"x6" FOUNDATION VENT 1 18”x24” CRAWL SPACE ACCESS

Cool Roofs: Rooiing products with a density/weight of 5lb per sq.ft. or more (concrete, clay tiles, slate and some synthetic roof coverings), shall meet 'Cool Roofs’ standards as required by California Energy Commission. Roofing material shall bear a minimum aged solar reflectance of 0.15 and thermal emittance of 0.75, or a minimum SRI of 10.

ATTIC VENTILATION | OVER REST OF ADDITION REQUIRED 1/150 PROPOSED SF = 486 REQUIRED NFAV SF = 3.2 QTY DESC 16 3-2” DIA VENT HOLES EA. OTHER RAFTER 4 MODEL ‘S’ ROOF TILE VENT 0 CJ Metal Half Round Dormer Vents DM30 PROV. NFAV= 3.7 REQ. NFAV= 3.2 NFAV = NATURAL FREE AIR VENTILATION

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com E: T: M: W:

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

VR DRAFTING

TOTAL

6.6

NFAV EA. SFTOTAL NFAV 0.1 1.3 0.7 2.7 0.9 0.0 TOTAL 4.0

CALCULATIONS 150

1" ACTUAL

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

BY REVISIONS DATE CALCULATIONS 150 NFAV EA. SFTOTAL NFAV 0.1 1.0 0.7 2.7 0.9 0.0 TOTAL 3.7

Date: Scale:

2/2/12 AS NOTED

Drawn:

1'-0"

2.

NFAV EA. SFTOTAL NFAV 0.3 4.2 2.4 2.4

CALCULATIONS 150

Job:

Permanent lighting shall comply with the mandatory measures listed on forms MF-1R attached.

335.001

Sheet

A1.07 Plotted On:

VICENTE REYES

MONTIJO

2/2/12

ROOF PLAN

2.09

(E) R.R.

Y

3. (E) R.R.

Y

LE

AL )V

(E

(E) RIDGE BOARD

(E) SLOPE

2.

508 S ASTELL AVE WEST COVINA, CA 91790 Tel: 1.626.484.4600

2.03 A A1.09

OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/16-IN. MINIMUM AND 1/4-IN. MAXIMUM OPENING. A MINIMUM OF 1-IN. AIRSPACE SHALL BE PROVIDED BETWEEN INSULATION AND ROOF SHEATHING. UNDER-FLOOR VENT OPENINGS SHALL HAVE CORROSION-RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/8-IN. MINIMUM AND 1/4-IN. MAXIMUM OPENING.

Chuck & Delores Montijo

4:12 SLOPE

2x8 R.R. @ 16" O.C.

4x

(E) RIDGE BOARD

1.

2.03

LE

(E) R.R.

IP

8

H

VENT NOTES:

NEW FAMILY ROOM, MASTER BED & BATH ADDITION

H

8

IP

4x

A A1.09

(E

)V AL

IP

4:12 SLOPE

2.11 4:12 SLOPE

11 A1.10

2.09 (E) SLOPE

2.11 ROOF TILE VENT (TYPICAL)

B A1.09

14 A1.10

01 A1.07

(E) R.R.

2.10 TYPICAL BLOCK VENT 3-2" DIA HOLES WITH CORROSION RESISTANT MESH (TYPICAL)

ROOF 2x8 R.R. @ 16" O.C.

DISCLAIMER NOTICE

2x8 R.R. @ 16" O.C.

2x8 R.R. @ 16" O.C.

2.03

(E) SLOPE

4x 8

IP H

13 A1.10

(E) R.R.

(E) SLOPE

2.08 OWENS CORNING VENTSURE LOW PROFILE SLANT BACK ROOF VENT. TO BE INSTALLED PER MFR. SPECS. COLOR TO MATCH ROOFING. TYPICAL FOR ALL ROOF VENTS

2.04 2.05 2.06

4x 8

B A1.09

13 A1.10

18 A1.10

14 A1.10

NEW

4:12 SLOPE

14 A1.10

2x10 RIDGE BOARD

2x8 R.R. @ 16" O.C.

2.07 INSTALL 24 GA GALVANIZED SM RAIN GUTTERS AND DOWNSPOUTS.

2.10

2.09 GALVANIZED CRICKET SLOPE MATCH EXISTING

ROOF

SLOPE MATCH EXISTING

2x8 R.R. @ 16" O.C.

2x8 R.R. @ 16" O.C.

Y

IP H

LE VA L

SLOPE MATCH EXISTING

IP H 4x 8

NEW

2.05 INSTALL 1/2" LOUISIANA PACIFIC (LP BUILDING PRODUCTS) "TECHSHEILD", RADIANT BARRIER OSB ROOF SHEATHING AT ROOF.

2.07

2.06 PROVIDE ATTIC CROSS VENTILATION EQUAL OR GREATER TO 1/300 OF THE ATTIC AREA. 1/300 OK WHEN USING RADIANT BARRIER

IP

H

2x8 R.R. @ 16" O.C. @4:12 SLOPE

8

2x

IP

2.02

2.01

H

8 4x

Y

LE

L VA

11 A1.10

8 4x

2x8 R.R. @ 16" O.C. @4:12 SLOPE 14 A1.10

2x8 R.R. @ 16" O.C. 11 A1.10

4x 8

IP

4:12 SLOPE

13 A1.10

2x 8

01

2x10 RIDGE BOARD

1'-0"

4:12 SLOPE

=

H

SCALE: 1"

8 4x

CRICKET

2x8 R.R. @ 16" O.C.

11 A1.10

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

11 A1.10

R.R. (PER PLAN)

2x10 RIDGE BOARD

S

CRICKET, RIBS @ 16" O.C.

VICENTE J. REYES

2.04 INSTALL CLASS - 'A' FIRE RATED, EAGLELITE LIGHTWEIGHT ROOF TILE, CAPISTRANO/VALENCIA. APPROX. 570lb per 100sq.ft.(ICC-ES ESR 1900). TO BE INSTALLED PER MFR. SPECS.

1/2" PLY.

DIS T w/ T ANCE VAR APE IE R

RESIDENCE


12"

NEW LIGHTWEIGHT ROOF TILE MIN. CLASS 'A' (TYPICAL)

NEW ROOF

4" 12" 3+"

TEMPERED

NEW 7/8" STUCCO IS APPLIED OVER PLY SHEATHING PROVIDE 2-LAYERS GRADE 'D' PAPER UNDER LATH

1'-0"

NEW LIGHTWEIGHT ROOF TILE MIN. CLASS 'A' (TYPICAL)

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

SCALE: 1/4" =

E: T: M: W:

WEST ELEVATION

VR DRAFTING

W

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

EXISTING

±0" F.F. | 1ST FLOOR

VICENTE J. REYES

16'-8"

14'-11"

EXISTING ROOF

NEW ROOF

13'-5"

+8'-1" TOP PLATE

EXISTING ROOF

NEW ROOF

12" 3+"

14'-11"

+10'-1" FAM.RM TP

EXISTING NEW WAINSCOT (TYPICAL)

16'-8"

DISCLAIMER NOTICE

EXISTING

8'-1"

13'-5"

+8'-1" TOP PLATE

14'-11"

EXISTING ROOF

NEW VENEER STONE/EQUIV. APPLIED OVER EXTERIOR SHT'G (PER MFR. SPECS, TYP.)

TEMPERED

±0" F.F. | 1ST FLOOR

SOUTH ELEVATION 1'-0"

12"

7'-1"

NEW ROOF

NEW ROOF

5'-1"

4"

4"

EXISTING ROOF

NEW 7/8" STUCCO IS APPLIED OVER PLY SHEATHING PROVIDE 2-LAYERS GRADE 'D' PAPER UNDER LATH

±0" F.F. | 1ST FLOOR

E

EAST ELEVATION SCALE: 1/4" =

NEW LIGHTWEIGHT ROOF TILE MIN. CLASS 'A' (TYPICAL)

1'-0"

12"

1" ACTUAL

4"

NEW ROOF

EXISTING ROOF

12"

EXISTING ROOF

3+"

NEW ROOF

EXISTING ROOF

+10'-1" FAM.RM TP

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

12"

BY REVISIONS DATE

3+"

EXISTING NEW 7/8" STUCCO IS APPLIED OVER PLY SHEATHING PROVIDE 2-LAYERS GRADE 'D' PAPER UNDER LATH

±0" F.F. | 1ST FLOOR

14'-11"

13'-5"

10'-1"

8'-1"

14'-11"

+8'-1" TOP PLATE

16'-8"

NEW ROOF

Date:

2/2/12

Scale:

AS NOTED

Drawn: Job:

335.001

Sheet

N

NORTH ELEVATION SCALE: 1/4" =

A1.08

1'-0"

Plotted On:

VICENTE REYES

MONTIJO

2/2/12

ELEVATIONS

EXISTING

10'-1"

NEW VENEER STONE/EQUIV. APPLIED OVER EXTERIOR SHT'G (PER MFR. SPECS, TYP.)

8'-1"

14'-11"

14'-11"

16'-8"

+8'-1" TOP PLATE

508 S ASTELL AVE WEST COVINA, CA 91790 Tel: 1.626.484.4600

NEW LIGHTWEIGHT ROOF TILE MIN. CLASS 'A' 12"

Chuck & Delores Montijo

SCALE: 1/4" =

NEW FAMILY ROOM, MASTER BED & BATH ADDITION

S

+10'-1" FAM.RM TP

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

NEW ROOF +10'-1" FAM.RM TP

RESIDENCE


HORTON RESIDENCE This project is a remodel to a single family dwelling. The scope of work was to remodel First Floor-Kitchen, Second Floor-Master Bath, and Bath-02 with Jack & Jill access (not shown, under separate permit). The front landscape was also remodeled. I designed and laid out new steps, gated access, and a wall to accommodate a slight slope at front entry landscape.

existing disbursement out to street.

This Project was Built.

9'-10"

2'-0" 1'-3"

2'-0" 6"

2'-0"

16'-7"

EXISTING LANDSCAPE

2'-10"

6"

17'-3"

5'-0"

13'-10"

3'-0"

5'-0"

4'-0"

7'-6"

ENTRY

6'-0"

1'-6"

6'-0"

PLANTER AREA

PLANTER AREA

EXISTING SIDEWALK

VICENTE REYES EXISTING PARKWAY

808 G L E N M O N T

HORTON

RESIDENCE


3'-10" 10'-11" 4'-3"

14'-9" 9'-8" 32'-4" 11'-0"

F.F. | 2nd FLOOR EXISTING FIRST FLOOR PLAN

SCALE: 1/4" = SCALE: 1/4" =

1'-0"

VICENTE REYES BEDROOM-02

BATH-01 4'1 1/2"x5'10"

ALCOVE (E)FIREPLACE

7'-6" 11" 4'-8" 8'-0" 6'-9"

48'-1" 4'1 1/2"x5'10"

ALCOVE

3'-4" 8'-4"

2'4"x6'8"

7'-5" 3'-4" 2'-8" 5'-5" 2'-8"

CLOSET 2'10"x5'10"

6'-0"

2'6"x6'8"

CLOSET

2'6"x6'8"

NOOK

DINING ROOM

4'4"x6'8"

3'6"x6'8" 2'10"x5'10"

15'-3"

3'-7"

47'-1"

HORTON

FOYER

!

2'-7"

31'-0"

3'-9"

3'-0"

Date:

Scale:

Job:

Plotted On:

LLP Construction 840 Norway Lane Los Angeles, CA 90049 (310)922-4034

Bryan W. Fisher

LLP Construction

7'-3"

5'-0"

2'0"x6'8"

2'5"x4'0"

8'-0"

5/14/13

E: T: M: W:

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

VICENTE J. REYES

VR DRAFTING

2'0"x6'8"

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

DISCLAIMER NOTICE

55'-1"

2'-7"

(E) WINDOWS TO BE RELOCATED 3'-8"

LAUNDRY 2'6"x4'0"

BEDROOM-01 2'6"x4'0"

CLOSET

2'6"x6'8"

16'-7"

BATH-01

7'-8"

2'6"x6'8" 2'-0"

2'6"x6'8" 2'6"x6'8"

2'0"x6'8"

CLOSET

10'-10"

1'3"x2'0"

Horton Residence 808 Glenmont Avenue Los Angeles, CA 90024 ____-____-_________

LIVING ROOM

1'3"x2'0"

3'-7"

KITCHEN 2'4"x3'0"

HALLWAY

2'8"x6'8"

10'-10" 3'-9"

26'-7"

CLOSET

2'5"x4'0"

2'-2"

BASEMENT ACCESS

8'-0"

existing disbursement out to street.

4'-3"

FAMILY ROOM 2'4"x3'0"

7'6"x5'10" 2'0"x6'8"

POWDER ROOM

4'-0"

16'-5"

UP

2'-11"

7'-11"

2'6"x6'8" 2'4"x3'0"

1'3"x2'0"

9"

2'5"x4'0"

2'10"x5'10"

5'0"x7'0" 4'-10"

2'6"x6'8"

1'3"x2'0"

1'-5"

8'9 9/16"x6'8" 2'4"x6'8"

5'0"x6'8"

4'-3"

8'-9"

3'-0"

4'-6"

2'10"x5'10"

(E)FIREPLACE

3'-1"

5'-6"

5'-4"

4'-3"

SHOWER 2'10"x5'10"

CLOSET

2'6"x6'8" 2'-6"

2'10"x5'10"

DN

4'-4"

4'5"x6'8"

BATH-02 4'1 1/2"x5'10"

MASTER BATH 53'-11"

HALLWAY

4'-1"

CLOSET

15'-8"

3'-5"

BEDROOM-03

4'-4" 9'-11"

INTERIOR REMODEL OF EXISTING S.F.D.

BALCONY

3'-1" 3'-5"

2'6"x6'8"

SHOWER

11"

4'4 3/8"x6'8"

17'-2"

5'-6"

SUN ROOM

28'-7"

3'-3"

7'-6"

6'-7"

5'-3"

4'1 1/2"x5'10"

MASTER BEDROOM

4'-1"

CLOSET

1'-6"

55'-0"

MASTER CLOSET 3'-3"

3'-0"

5'-0"

3'-6" 1'-1"

5'-6"

3'-3"

4'-9"

8'-9"

13'-11"

5'-10"

7'-0"

2'-7"

1'-9" 15'-10"

27'-3"

3'-8"

4'-3"

LINEN

13'-2"

17'-5"

2'-7"

2'-7"

DECK HALLWAY

9'-6"

3'-5"

STAIR BALCONY

3'-7"

3'-5"

2'-7"

11'-8"

55'-0"

2'-11"

5'-8"

3'-10"

19'-1"

13'-11" 14'-7"

Drawn:

5/14/13

387.001

AS NOTED

Sheet

A1.04

Existing Floor Plans

3'-3"

3'-3"

Intellectual Property: Any and all drawings represented here is the Intellectual property of Vicente J. Reyes and VR DRAFTING. Any exact or resembling reproduction of any or parts of this property is subject to his approval and or consent. Failure to comply will result in U.S. Intellectual Property infringement.

48'-1" 47'-1" 22'-8" 3'-1"

2'6"x6'8"

5'-8" IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

1" ACTUAL

1'-0"

BY REVISIONS DATE

RESIDENCE


Demo Door / Window shown with 'X'

Demo wall (unless otherwise noted)

DEMO SECOND FLOOR DEMO FIRST FLOOR

SCALE: 1/4" = SCALE: 1/4" =

1'-0"

VICENTE REYES 1'-0"

Date:

Scale:

Job:

Plotted On:

HORTON 387.001

Sheet

A1.05 5/14/13

Demo Plans

DEMO LEGEND Horton Residence 808 Glenmont Avenue Los Angeles, CA 90024 ____-____-_________

INTERIOR REMODEL OF EXISTING S.F.D.

existing disbursement out to street.

DISCLAIMER NOTICE

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

!

LLP Construction 840 Norway Lane Los Angeles, CA 90049 (310)922-4034

Bryan W. Fisher

LLP Construction

Intellectual Property: Any and all drawings represented here is the Intellectual property of Vicente J. Reyes and VR DRAFTING. Any exact or resembling reproduction of any or parts of this property is subject to his approval and or consent. Failure to comply will result in U.S. Intellectual Property infringement.

Load bearing wall to be pushed out.

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

1" ACTUAL

BY REVISIONS DATE

Drawn:

5/14/13 AS NOTED

RESIDENCE

E: T: M: W:

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

VICENTE J. REYES

VR DRAFTING


SCALE: 1/4" = 10'-11" 4'-3" (N) SHOWER 30" MIN.

ALCOVE 2'-3"

14'-9" 9'-8" 11'-0"

PROPOSED SEOND FLOOR

1'-0"

VICENTE REYES BALCONY

32'-4"

BATH-01

7'-6" 11"

SCALE: 1/4" = 1'-0"

4'-8" 8'-0" (E)FIREPLACE

48'-1" 6'-9"

EF "ENERGY STAR" COMPLIANT EXHAUST FAN w/HUMIDISTAT (9.506.1)

PROPOSED FIRST FLOOR

3'-4" 8'-4"

BEDROOM-02

7'-5" 3'-4" 2'-8"

2'8"x6'8"

5'-5" 2'-8"

1.01 1.02 1.03 1.05 1.07 1.09 1.11 1.15 1.17 1.19 1.21 1.23 1.25 1.27

CLOSET 30 "

BASEMENT ACCESS

6'-0"

PANTRY

1.02

1.21 1.05

1.17

1.03

3'-7"

Upper cabinets Lower cabinets 48" Fridge Dishwasher Sink 48" Range Limestone hood Microwave under counter Utility Sink Bar Stool (typical) Island Island Leg (support) Desk 30" Double Oven

HORTON

1.07

1.15

1.02

FOYER DINING ROOM

ALCOVE CLOSET

LAUNDRY

KITCHEN New Floor Area 28 sq.ft. 1.01

1.02

15'-3"

5'-8"

47'-1"

WALL LEGEND EXISTING WALL

Date:

Scale:

Job:

Plotted On:

LLP Construction 840 Norway Lane Los Angeles, CA 90049 (310)922-4034

Bryan W. Fisher

LLP Construction

3'-0"

8'-0"

5/14/13

E: T: M: W:

vicente.vrdrafting@gmail.com 1.626.249.0156 1.626.823.9578 www.vrdrafting.com

P.O. BOX 406 MONROVIA, CALIFORNIA 91017

VICENTE J. REYES

VR DRAFTING

BEDROOM-01

This record drawing has been prepared, in part, based upon information furnished by others. While this information is believed to be reliable, VR DRAFTING assumes no responsibility for the accuracy of this record drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to VR DRAFTING. Those relying on this record document are advised to obtain independent verification of its accuracy.

3'-9"

2'6"x3'0"

Horton Residence 808 Glenmont Avenue Los Angeles, CA 90024 ____-____-_________

1.19

DISCLAIMER NOTICE

1.23

!

9'-5"

PANTRY 38'-10"

2'8"x6'8"

2'-7"

"

55'-1"

SHWR

2'-7"

POWDER ROOM

7'-4"

INTERIOR REMODEL OF EXISTING S.F.D.

24'-6"

4'-1"

30

4'-11"

BATH-01

(E) WINDOWS RELOCATED

2'-10"

7'-11"

FAMILY ROOM

4'-0"

DW 2'4"x3'0"

8'-0" 2'-11"

2'4"x3'0"

4'-10"

2'4"x3'0"

4'-6"

6'-5"

5'-4"

8'-0"

5'-0"

2'-6"

1.11

16'-7"

CLOSET

10'-10"

4'-4"

2'8"x6'8"

9"

3'-0"

4'-4"

10'8"x7'0" (New Arch)

1'-5"

5'-6"

3'-5"

16'-3"

4'-4"

15'-8"

3'-5"

3'-1" 9'-11"

existing disbursement out to street.

CLOSET

14'-7"

1.09

BATH-02

4'-3"

6'-10"

(E)FIREPLACE

HALLWAY 8'-9"

5'-6"

4'-0"

3'-1"

3'-3"

BEDROOM-03

4'-1"

CLOSET 6'-7"

SUN ROOM

53'-11"

55'-0"

3'-3"

3'-0"

7'-6"

3'-6" 1'-1"

LINEN

HALLWAY

5'-6"

11"

4'-3"

17'-2"

1'-6"

4'-1"

(N) MASTER BATH

5'-3"

28'-7"

4'-9"

EF

7'-0"

DECK

15'-10"

27'-3"

1'-0"

2'-7"

ARCH

12'-8"

3'6"x3'0"

2'-7"

7'-0"

1'-6"

5'-8"

7'0"x7'3 1/2"

(N) MASTER CLOSET

4'-4"

8'-9"

13'-11"

15'-10"

3'-6"

1'-6" 2'8"x6'8"

2'-7"

4'-0"

5'-8"

13'-2"

13'-2"

48'-1"

Drawn:

5/14/13

387.001

AS NOTED

Sheet

A1.06

Proposed Floor Plans

3'-10"

4'-3"

1'-11"

MASTER BEDROOM STAIR BALCONY

3'-7"

3'-5"

3'-2"

11'-8"

55'-0"

3'-5"

2'8"x6'8"

2'-1"

3'-10"

19'-1"

2'-11" 17'-5"

2'-7"

15"

3'-3"

3'-3"

Intellectual Property: Any and all drawings represented here is the Intellectual property of Vicente J. Reyes and VR DRAFTING. Any exact or resembling reproduction of any or parts of this property is subject to his approval and or consent. Failure to comply will result in U.S. Intellectual Property infringement.

13'-11" 47'-1" 22'-8" 10'-10"

10'-2"

5'-0"

CLOSET

LIVING ROOM PANTRY

IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES.

1" ACTUAL

BY REVISIONS DATE

NEW WALL

RESIDENCE


66’ MUSTANG - PERSONAL INTEREST This is a project of my 66’ Mustang. The car was in working order but the engine clanked and the exhaust gave off white smoke. I purchased a repair manual and began to troubleshoot. I removed the valve cover and discovered that the smoke was from a faulty header, and several of the pushrods were broken. My son and I removed the header and sent it out for rebuild.

PUSH ROD HEADER

The engine block had a bunch of grime and we removed the residue for clean performance. Below is a before and after image.

Below is an image of the reinstalled header which my son and I torqued down and adjusted the rocker arms with the proper ignition timing. The carburetor was also rebuilt. The car is still a work in progress but is now running like new.

ENGINE BLOCK & GRIME

BEFORE

VICENTE REYES

AFTER

66’

M U S TA N G


VICENTE REYES

MISCELLANEOUS


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.