GENERAL CATALOGUE updated edition
Made in Italy – Technology and Design for the future
Pedrollo S.p.A. was founded in 1974. Having grown over the years to assume an international character, the company is now recognised as one of the world leaders in the domestic pump sector. Currently the company covers an area of 100.000 m2 and is characterised by its highly automated production process. The constant quality control of the entire production cycle and the use of the most advanced technological solutions available guarantees that the products are of an extremely high quality. Thanks to the use of the most sophisticated robots and advanced production lines available, the company is capable of producing over 2.000.000 pumps a year from a range covering over 100 different families of pumps.
Pedrollo pumps are sold in over 160 countries worldwide via a sales network capable of offering its clients the choice from a vast range of products suitable for most domestic, civil, agricultural and industrial applications. An international sales team, composed of professionals from various parts of the world, ensures that the client is able to count on an extremely high level of service and personalised advice regarding the best solution to adopt. The research and design department is equipped with the most advanced hardware and software available. A modern laboratory where hydraulic tests take place, workstations where fluiddynamic and finite element analysis is carried out, together with creativity and passion, all combine to produce new pumps and to continually improve the existing range with particular attention being paid to sturdiness and low energy consumption, thus providing each and every client with a simple and reliable product capable of providing surprising levels of performance.
All major components are manufactured ‘in house’ by Pedrollo. Starting with raw materials, the foundry, machine shop, sheet metal works and motor winding facilities, under the guidance of our QA Inspectors, produce high quality precision components at all times.
The final assembly of our pumps takes place on automated assembly lines, capable of providing a high assembly quality while carrying out automated tests at the same time, thus ensuring that the final product is produced in the shortest time possible.
Before approval is given for the production of a new pump, all new models are tested in our laboratory. Fitted with a rig capable of reproducing the most strenuous of working conditions, the laboratory allows us to test the success of the design process.
REGULATION (EU) N. 547/2012 •• Minimum efficiency index MEI ≥ 0,10 for water pumps according to the (EU) Regulation
current from the 1th of January 2013.
•• The benchmark for most efficient water pumps is MEI ≥ 0,70. •• The efficiency of a pump with a trimmed impeller is usually lower than that of a pump
with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter.
•• The operation of this water pump with variable duty points may be more efficient
and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system.
•• Information on benchmark efficiency is available www.europump.org/efficiencycharts.
Index MULTI-STAGE
PERIPHERAL PK
16
2÷4CP
STANDARDIZED CENTRIFUGAL 86
F
130
PKS
PQ PQ-Bs
20
24
PV
32
PQA
36
2÷4CR
90 F-INOX
158
FG
164
VERTICAL MULTI-STAGE
MK
94
SUBMERSIBLE MULTI-STAGE SELF-PRIMING
CENTRIFUGAL CK CP
AL-RED
40
54
CKR
JSW
NK 98
106
4” SUBMERSIBLE PERIPHERAL
DAVIS HF
58
JCR
178
184
118
4” SUBMERSIBLE MONOBLOCK NGA NGA-PRO
66 PLURIJET
2CP
74
122
4BLOCK
188
SUBMERSIBLE
4” SUBMERSIBLE
TOP
SAR
230 328
4SR
192 RX
252 PORTABLE
ZX
272
ZD
276
6” SUBMERSIBLE
6SR
BETTY
336
EASYPUMP-EP
208
D
280
VX-I
284
MC-I
288
VX
292
MC
296
338
HYDROFRESH
340
4” - 6” MOTORS 4PD
220
4FK
222
6PD
224
COMBIPRESS “CB2” DC
300
342 VXC
304
MC
308
SUBMERSIBLE MULTI-STAGE
EASYSMALL-EASYPRESS-EASYPRO 344 346
TOP MULTI
226
PVXC
320
PMC
324
348 ACCESSORIES 350
PK Pumps with peripheral impeller
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. Thanks to their reliability, the fact that they are easy to use and are economical, they are ideal for domestic use and in particular for distributing water in combination with small pressure sets and for the irrigation of gardens and allotments. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 90 l/min (5.4 m³/h) •• Head up to 100 m •• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +60 °C •• Ambient temperature up to +40 °C (+45 °C for PK 60) •• Max. working pressure: ••
– 6.5 bar for PK 60-65-70-80 – 10 bar for PK 90-100-200-300 Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
PATENTS - TRADE MARKS - MODELS
•• Registered model PKm60 n° 009875394 •• Motor bracket: patent n° IT1243605 ••
(reduces the risk of the impeller locking after long periods of inactivity) Registered Community Design n° 001894478
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for PK 70-80-90-100-200-300
GUARANTEE 1 year subject to terms and conditions
16
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
PK300 PK200 PK90
PK100
PK80
Head H (metres) 4
PK70
PK65
PK60
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
5.4
l/min
0
5
10
15
20
25
30
35
40
50
60
70
80
90
PKm 60®
PK 60®
0.37
0.50
40
38
33.5
29
24
19.5
15
10
5
PKm 65
PK 65
0.50
0.70
55
50
45.5
40.5
36
31
27
22
17
PKm 70
PK 70
0.60
0.85
65
62
57
52
47
42
37
32
27
18
PKm 80
PK 80
0.75
1
70
66
61
56
51
46
41
36.5
31
22
PKm 90
PK 90
0.75
1
90
82
71
60
49
38
27
17
5
PKm 100
PK 100
1.1
1.5
85
80
75
70
65
60
55
50
45
35
25
15
PKm 200
PK 200
1.5
2
90
86
81
76
71
65.5
60
55
50
40
30
20
10
–
PK 300
2.2
3
100
95
90
85
80
75
70
65
60
50
40
30
20
H metres
Q = Flow rate H = Total manometric head HS = Suction height
8
10
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
17
PK POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
MOTOR BRACKET
Aluminium with brass insert (patented), reduces the risk of impeller seizure
3
IMPELLER
Brass, with peripheral radial vanes
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
PK 60-65-70-80 PK 90 PK 100-200-300
AR-12 MG1-12 FN-14
Ø 12 mm Ø 12 mm Ø 14 mm
Pump
Model
PK 60-65 PK 70-80-90 PK 100-200-300
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ
Pump
Capacitance
6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Silicon carbide Graphite
Graphite Graphite Ceramic
NBR NBR NBR
Single-phase
(230 V or 240 V)
(110 V)
PKm 60 PKm 65 PKm 70 PKm 80 PKm 90 PKm 100 PKm 200
10 μF 450 VL 14 μF 450 VL 16 μF 450 VL 20 μF 450 VL 20 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL
25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL
PKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PK: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
7
6
1
18
3
5
2
6
4
8
DIMENSIONS AND WEIGHT f
i
h1
DN1
h3
h
h2
DN2
s a
MODEL
w
n1 n
m
PORTS
Single-phase
Three-phase
PKm 60®
PK 60®
PKm 65
PK 65
PKm 70
PK 70
PKm 80
PK 80
PKm 90
PK 90
PKm 100
PK 100
PKm 200
PK 200
–
PK 300
DN1
DIMENSIONS mm
DN2
a 39
1”
¾” 1”
1”
¾” 1”
f
h
h1
207
145
56
232
152
63
55
285
46
278
55
350
180
212
h2
h3
75
71
80
i
131
m
n
55
138
85
156
84
155
94
kg
174
20
n1
118
80
93-100 100
w
s
53 7
90
140
112
62
19 20
100
164
125
85
9
1~
3~
5.2
5.2
6.6
6.1
10.0
9.9
10.0
9.9
10.3
10.0
14.4
12.4
15.5
13.4
–
15.6
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
PKm 60®
2.5 A
2.4 A
5.5 A
PKm 65
3.7 A
3.4 A
7.4 A
PKm 70
5.2 A
4.8 A
10.8 A
PKm 80
5.2 A
4.8 A
10.8 A
PKm 90
5.6 A
5.1 A
11.5 A
PKm 100
9.0 A
8.2 A
18.0 A
PKm 200
11.5 A
11.0 A
24.0 A
PK 60® PK 65 PK 70 PK 80 PK 90 PK 100 PK 200 PK 300
2.0 A 3.0 A 3.8 A 3.8 A 4.0 A 6.2 A 7.6 A 9.3 A
1.15 A 1.7 A 2.2 A 2.2 A 2.3 A 3.6 A 4.4 A 5.4 A
– – – – – 2.05 A 2.5 A 3.15 A
1.9 A 2.8 A 3.3 A 3.3 A 3.8 A 5.7 A 7.0 A 8.7 A
1.1 A 1.6 A 1.9 A 1.9 A 2.2 A 3.3 A 4.0 A 5.0 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
3~
n° pumps
1489
1272
1272
330
1271
PKm 60®
PK 60®
240
PKm 65
PK 65
189
1352
1177
PKm 70
PK 70
102
1280 1044 1034
PKm 80
PK 80
102
PKm 90
PK 90
PKm 100
PK 100
PKm 200 –
H (mm)
kg 1~
3~
2009 1740
1740
243
1715
1628
1506
170
2040 1724
1707
1280 1044 1034
170
2040 1724
1707
102
1280
170
2040 1775
1724
72
1520 1060
910
84
1750
1230 1060
PK 200
72
1520
1140
990
84
1750
1320
1150
PK 300
72
1520
–
1140
84
1750
–
1330
1075 1044
H
0
Three-phase
80
Single-phase
00
12
19
PKS Self-priming pumps with peripheral impeller
PERFORMANCE RANGE
•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 70 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +60 °C •• Ambient temperature up to +40 °C (+45 °C for PKS 60) •• Max. working pressure 6.5 bar •• Continuous service S1
INSTALLATION AND USE Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their compactness, reliability and the fact that they are easy to use, they are suitable for use in domestic applications such as the distribution of water in combination with small pressure sets, for the irrigation of gardens and allotments, for drawing water from tanks and for all those other situations where air or water may be present in the water to be pumped. The pump comes complete with a flap-check valve. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
PATENTS - TRADE MARKS - MODELS
•• Motor bracket: patent n° IT1243605 •• Registered Italian model n° 72753
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for PKS 70, PKS 80
GUARANTEE 1 year subject to terms and conditions
20
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
PKS 80 PKS 70
Head H (metres) 4
PKS 65
PKS 60
Flow rate Q 4 MODEL
POWER
Single-phase Three-phase
kW
HP
PKSm 60
PKS 60
0.37
0.50
PKSm 65
PKS 65
0.50
0.70
PKSm 70
PKS 70
0.60
0.85
PKSm 80
PKS 80
0.75
1
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
5
10
15
20
25
30
35
40
45
50
40
38
33.5
29
24
19.5
15
10
5
55
50
45.5
40.5
36
31
27
22
17
12.5
8
65
62
57
52
47
42
37
32
27
22
18
70
66
61
56
51
46
41
36.5
31
27
22
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
HS = Suction height
21
PKS POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1 and the suction port with built-in flap-check valve
2
MOTOR BRACKET
Aluminium with brass insert (patented), reduces the risk of impeller seizure
3
IMPELLER
Brass, with peripheral radial vanes
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-12
Ø 12 mm
6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
Pump
Model
PKS 60-65 PKS 70-80
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
PKSm 60 PKSm 65 PKSm 70 PKSm 80
10 μF 450 VL 14 μF 450 VL 16 μF 450 VL 20 μF 450 VL
25 μF 250 VL 25 μF 250 VL 60 μF 250 VL 60 μF 250 VL
PKSm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PKS: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
22
3
5
2
7
4
6
8
DIMENSIONS AND WEIGHT f
n DN2
h1
h
DN1
h2
i
s a
w
MODEL
m
n1
PORTS DN1
DIMENSIONS mm
DN2
Single-phase
Three-phase
PKSm 60
PKS 60
PKSm 65
PKS 65
PKSm 70
PKS 70
PKSm 80
PKS 80
260
1”
1”
a
f
29
h
h1
h2
i
197
183
149
55
222
190
156
80
198
164
34
110
m
90
kg n 149 160
n1
w
93-100 100 112
s
53 7 62
1~
3~
6.1
6.1
7.4
6.9
10.6
9.7
10.6
9.7
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
PKSm 60
2.5 A
2.4 A
5.5 A
PKS 60
2.0 A
1.15 A
1.9 A
415 V 1.1 A
PKSm 65
3.7 A
3.4 A
7.4 A
PKS 65
3.0 A
1.7 A
2.8 A
1.6 A
PKSm 70
5.2 A
4.8 A
10.8 A
PKS 70
3.8 A
2.2 A
3.3 A
1.9 A
PKSm 80
5.2 A
4.8 A
10.8 A
PKS 80
3.8 A
2.2 A
3.3 A
1.9 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
1~
3~
PKS 60
210
1569
1305
1305
270
1994
1671
1671
PKS 65
150
1150
1134
1059
210
1564
1578
1473
Single-phase
Three-phase
PKSm 60 PKSm 65 PKSm 70
PKS 70
105
1300
1130
1040
168
1980 1800 1650
PKSm 80
PKS 80
105
1300
1130
1040
168
1980 1800 1650
H
0 80
00
12
23
PQ Pumps with peripheral impeller
PERFORMANCE RANGE
•• Flow rate up to 90 l/min (5.4 m³/h) •• Head up to 100 m
APPLICATION LIMITS
•• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C
INSTALLATION AND USE Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. The hydraulic characteristics of these pumps, coupled with their compactness, makes them suitable for use in both domestic and industrial applications. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
(+45 °C for PQ 60, PQ 60-Bs)
•• Max. working pressure:
– 6.5 bar for PQ 60-65 – 10 bar for PQ 70-80-81-90-100-200-300 •• Continuous service S1
PATENTS - TRADE MARKS - MODELS
•• Registered model PQm60 n° 0001520591 •• Motor bracket: patent n° IT1243605 •• Registered Community Design n° 002146548
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
24
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency •• IP X5 class protection for PQ 70-80-90-100-200-300
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
PQ300 PQ200
Head H (metres) 4
PQ90
PQ80 PQ70
PQ65
PQ60
PQ100 PQ81
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
5.4
l/min
0
5
10
15
20
25
30
35
40
50
60
70
80
90
PQm 60®
PQ 60®
0.37
0.50
40
38
33.5
29
24
19.5
15
10
5
PQm 65
PQ 65
0.50
0.70
55
50
45.5
40.5
36
31
27
22
17
PQm 70
PQ 70
0.60
0.85
65
62
57
52
47
42
37
32
27
18
PQm 80
PQ 80
0.75
1
70
66
61
56
51
46
41
36.5
31
22
PQm 90
PQ 90
0.75
1
PQm 100
PQ 100
1.1
1.5
PQm 200
PQ 200
1.5
–
PQ 300
PQm 60-Bs PQm 65-Bs
90
8
H metres 85
82
71
60
49
38
27
17
5
80
75
70
65
60
55
50
45
35
25
15
2
90
86
81
76
71
65.5
60
55
50
40
30
20
10
2.2
3
100
95
90
85
80
75
70
65
60
50
40
30
20
PQ 60-Bs
0.37
0.50
40
38
33.5
29
24
19.5
15
10
5
PQ 65-Bs
0.50
0.70
55
50
45.5
40.5
36
31
27
22
17
10
8
➠ Bs= version with brass pump body
MODEL Single-phase Three-phase
POWER kW
HP
PQm 81
PQ 81
0.50
0.70
PQm 81-Bs
PQ 81-Bs
0.50
0.70
Q
m³/h
0
0.12
0.24
0.36
0.48
0.60
0.72
0.84
0.96
1.08
l/min
0
2
4
6
8
10
12
14
16
18
90
80
71
63
54
45
37
28
19
10
90
80
71
63
54
45
37
28
19
10
H metres
➠ Bs= version with brass pump body Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
25
PQ POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron (brass for PQ-Bs), complete with threaded ports in compliance with ISO 228/1
2
MOTOR BRACKET
Aluminium with brass insert (patented), reduces the risk of impeller seizure
3
IMPELLER
Brass, with peripheral radial vanes
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
PQ 60-65 PQ 70-80-81-90 PQ 60Bs-65Bs-81Bs PQ 100-200-300
AR-12
Pump
Model
6
BEARINGS
PQ 60-65-81 PQ 60Bs-65Bs-81Bs PQ 70-80-90 PQ 100-200-300 7
8
CAPACITOR
Rotational ring
Elastomer
Ø 12 mm
Ceramic
Graphite
NBR
MG1-12
Ø 12 mm
Silicon carbide
Graphite
NBR
FN-14
Ø 14 mm
Graphite
Ceramic
NBR
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ
Pump
ELECTRIC MOTOR
Materials Stationary ring
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
PQm 60 - 60Bs PQm 65 - 65Bs PQm 70 PQm 80 PQm 81 - 81Bs PQm 90 PQm 100 PQm 200
10 μF 450 VL 14 μF 450 VL 16 μF 450 VL 20 μF 450 VL 14 μF 450 VL 20 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL
25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL 25 μF 250 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL
PQm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PQ: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
26
3
5
7
2
4
6
8
DIMENSIONS AND WEIGHT i
f
h1
h3
h
DN1
h2
DN2
s a
MODEL Single-phase
PORTS
Three-phase
PQm 60®
PQ 60®
PQm 60-Bs
PQ 60-Bs
PQm 65
PQ 65
PQm 65-Bs PQm 70 PQm 80 PQm 81 PQm 81-Bs PQm 90 PQm 100 PQm 200 –
PQ 65-Bs PQ 70 PQ 80 PQ 81 PQ 81-Bs PQ 90 PQ 100 PQ 200 PQ 300
n1 n
m
w
DN1
1”
DIMENSIONS mm
DN2
1”
a
22
f
h
h1
190
145
101 113
h2
30
kg
h3
i
m
n
n1
131
76
55
118
93-100
143
78
216
152
108
138
76
255
180
121
151
w
s
1~ 5.1
5.1
5.4
5.4
6.4
5.9
6.7 9.7 9.7 6.6 6.5 9.9 14.1 15.2 –
6.2 9.0 9.0 6.2 6.1 8.8 12.2 14.1 15.2
53 80
120
100
83
90
138
112
62
7
½”
½”
18
214
152
119
22
141
71
80
120
100
56
¾”
¾”
22
255
180
126
27
153
84
90
138
112
62
1”
1”
25
318
212
140
30
170
89
100
164
125
85
9
3~
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
PQm 60® – PQm 60-Bs PQm 65 – PQm 65-Bs PQm 70 PQm 80 PQm 81 – PQm 81-Bs PQm 90 PQm 100 PQm 200
2.6 A 3.7 A 5.2 A 5.2 A 3.4 A 5.6 A 9.0 A 12.0 A
2.4 A 3.4 A 4.8 A 4.8 A 2.7 A 5.1 A 8.2 A 11.0 A
5.2 A 7.4 A 10.8 A 10.8 A 5.8 A 11.5 A 18.0 A 24.0 A
PQ 60® – PQ 60-Bs PQ 65 – PQ 65-Bs PQ 70 PQ 80 PQ 81 – PQ 81-Bs PQ 90 PQ 100 PQ 200 PQ 300
2.0 A 3.0 A 3.8 A 3.8 A 2.2 A 4.2 A 6.3 A 7.6 A 9.3 A
1.15 A 1.7 A 2.2 A 2.2 A 1.3 A 2.4 A 3.6 A 4.4 A 5.4 A
– – – – – – 2.05 A 2.5 A 3.15 A
1.9 A 2.8 A 3.3 A 3.3 A 2.0 A 3.8 A 5.7 A 7.0 A 8.7 A
1.1 A 1.6 A 1.9 A 1.9 A 1.15 A 2.2 A 3.3 A 4.0 A 5.0 A
PALLETIZATION MODEL Three-phase PQ 60® PQ 60-Bs PQ 65 PQ 65-Bs PQ 70 PQ 80 PQ 81 PQ 81-Bs PQ 90 PQ 100 PQ 200 PQ 300
H (mm) 1465 1240 1484 1484 1280 1280 1484 1484 1280 1510 1510 1510
CONTAINER kg
1~ 1330 1309 1407 1471 1013 1013 1450 1428 1034 1040 1120 –
3~ 1330 1309 1299 1363 942 942 1363 1342 922 900 1040 1120
n° pumps 352 306 270 243 170 170 270 270 170 96 96 96
H (mm) 1976 1563 1790 1625 2040 2040 1790 1790 2040 1970 1970 1970
kg 1~ 3~ 1819 1819 1676 1676 1752 1617 1652 1531 1673 1554 1673 1554 1806 1698 1779 1671 1707 1520 1380 1190 1480 1380 – 1480
H
0 80
Single-phase PQm 60® PQm 60-Bs PQm 65 PQm 65-Bs PQm 70 PQm 80 PQm 81 PQm 81-Bs PQm 90 PQm 100 PQm 200 –
GROUPAGE n° pumps 256 238 216 216 102 102 216 216 102 72 72 72
00
12
27
PQ 3000 Pump with peripheral impeller
PERFORMANCE RANGE
•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 180 m
APPLICATION LIMITS
•• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 18 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The hydraulic characteristics of this pump, coupled with its compactness, make it suitable for use in the industrial applications. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• Motor bracket: patent n° IT1243605
OPTIONALS AVAILABLE ON REQUEST
EN 60034-1 IEC 60034-1 CEI 2-3
•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency
CERTIFICATIONS
GUARANTEE
COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
28
1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
Head H (metres) 4
PQ3000
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
PQ 3000
2.2
3
Q
m³/h
0
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
10
15
20
25
30
35
40
45
50
180
160
145
132
118
105
92
78
63.5
50
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
29
PQ 3000 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY PLATE
Stainless steel AISI 316
3
MOTOR BRACKET
Aluminium, with brass insert and stainless steel shim disc that reduces the risk of impeller seizure
4
IMPELLER
Bronze, with peripheral radial vanes
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
FN-18 NU
Ø 18 mm
Materials Stationary ring
Rotational ring
Elastomer
Graphite
Ceramic
NBR
7
BEARINGS
6204 ZZ - C3 / 6204 ZZ - C3
8
ELECTRIC MOTOR
PQ 3000: three-phase 230/400 V - 50 Hz. ➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: H class. – Protection: IP X5.
1
2
30
7
4
3
7
6
5
8
DIMENSIONS AND WEIGHT i
f
h1
h3
h
DN1
h2
DN2
s a
MODEL Three-phase PQ 3000
w
n1
m
n
PORTS
DIMENSIONS mm
kg
DN1
DN2
a
f
h
h1
h2
h3
i
m
n
n1
w
s
3~
¾”
¾”
34
329
212
142
38
180
65
100
164
125
97
9
18.4
ABSORPTION MODEL
VOLTAGE (three-phase)
Three-phase
230 V
400 V
240 V
415 V
PQ 3000
11.5 A
6.6 A
10.8 A
6.2 A
PALLETIZATION MODEL
PQ 3000
GROUPAGE n° pumps
H (mm)
72
1840
CONTAINER kg
n° pumps
H (mm)
kg
1352
84
2114
1567
H
0 80
00
12
31
PV Pump with peripheral impeller
PERFORMANCE RANGE
•• Flow rate up to 10 l/min (0.6 m³/h) •• 50 Hz: head up to 42 m •• 60 Hz: head up to 55 m
APPLICATION LIMITS
•• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +45 °C •• Max. working pressure 10 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The design of this particularly compact brass pump offers an effective guarantee against the formation of rust and oxidation; as a result they are recommended for use in industrial applications such as cooling and conditioning. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• Motor bracket: patented n° IT1243605
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
32
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50/60 Hz n= 2900/3450 1/min HS= 0 m
0.5 60
0
1.5 0.5
2
1
2.5
1.5
2
55
180
50
160 PV55 - 60Hz
45
Head H (metres) 4
140 40 120
PV55 - 50Hz
35 30
100
25
80
20
60
15 40 10 20
5
0
0
1
0
2
3
0.1
MODEL
PVm 55
PV 55
5
0.2
POWER
Single-phase Three-phase
4
kW
HP
0.18
0.25
Q H
metres
6
0.3
Flow rate Q 4
7
8
0.4
9
0
10
0.5
0.6
m³/h
0
0.12
0.18
0.24
0.30
0.36
0.42
0.48
0.54
0.60
l/min
0
2
3
4
5
6
7
8
9
10
50 Hz
42
35
31
27.5
24
20.5
16
12.5
9
5
60 Hz
55
46
41.5
37
32.5
28
23.5
19
14.5
10
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
➠ The PV 55 pump is designed to work at 50 Hz and 60 Hz (see the characteristic curves)
33
PV POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Brass, with threaded ports in compliance with ISO 228/1
2
PUMP BODY BACK-PLATE
Brass
3
MOTOR BRACKET
Aluminium
4
IMPELLER
Brass, with peripheral radial vanes
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
MG1-12E
Ø 12 mm
7
BEARINGS
6201 ZZ / 6201 ZZ
8
CAPACITOR
Capacitance
9
Materials Stationary ring
Rotational ring
Elastomer
Silicon carbide
Graphite
EPDM
230÷240 V (50÷60 Hz)
110 V (50÷60 Hz)
10 μF 450 VL
25 μF 250 VL
PVm: single-phase 230 V - 50÷60 Hz with thermal overload protector built-in to the winding. PV: three-phase 230/400 V - 50÷60 Hz.
ELECTRIC MOTOR
➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
34
4
7
2
8
3
5
7
9
DIMENSIONS AND WEIGHT 90°
i DN1
f
h
h2
DN2
h1
h3
180°
s a
w
n1 n
m
90°
When rotating the pump body it is also necessary to rotate the pump body back-plate
MODEL Single-phase
Three-phase
PVm 55
PV 55
PORTS
DIMENSIONS mm
kg
DN1
DN2
a
f
h
h1
h2
h3
i
m
n
n1
w
s
1~
3~
¼”
¼”
11
188
145
56
40
96
25
55
118
93-100
63
7
4.5
4.5
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
PVm 55 (50Hz)
1.6 A
1.5 A
3.2 A
PV 55 (50÷60Hz)
1.7 A
1.0 A
PVm 55 (60Hz)
2.0 A
1.9 A
4.0 A
PALLETIZATION MODEL Single-phase
Three-phase
PVm 55
PV 55
GROUPAGE n° pumps
H (mm)
238
1240
CONTAINER kg
1~
3~
1095 1095
kg
n° pumps
H (mm)
1~
3~
306
1563
1401
1401
H
0 80
00
12
35
PQA Pumps with peripheral impeller
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. The RYTON and brass pump body construction guarantees against the formation of rust and oxidation. As a result of these characteristics these pumps are suitable for use in industrial applications such as cooling, conditioning and boiler feed. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 45 l/min (2.7 m³/h) •• Head up to 90 m •• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C (+45 °C for PQA 60)
•• Max. working pressure 10 bar •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
36
PATENTS - TRADE MARKS - MODELS
•• Motor bracket: patented n° IT1243605
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency •• IP X5 class protection for PQA 70-72-80-82-90
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
PQA90
PQA80
Head H (metres) 4
PQA70
PQA60
PQA82 PQA72
Flow rate Q 4
MODEL Single-phase Three-phase PQAm 60 PQA 60 PQAm 70 PQA 70 PQAm 72 PQA 72 PQAm 80 PQA 80 PQAm 82 PQA 82 PQAm 90 PQA 90
POWER kW 0.37 0.55 0.55 0.75 0.75 0.75
HP 0.50 0.75 0.75 1 1 1
Q
m³/h
0
0.1
0.3
0.6
0.9
1.2
1.5
1.8
1.9
2.3
2.7
3.0
l/min
0
2
5
10
15
20
25
30
32
38
45
50
40
38
35
29
23.5
18
12.5
7
5
65
62
58
52
45.5
39.5
33
27
24
16.5
8
65
-
62
57
52
47
42
37.5
35.5
29.5
22.5
70
66
62
56
49.5
43
37
31
28
20.5
12
70
-
66
61
56
51
46
41.5
39.5
34
26.5
90
86
79
68
56.5
45.5
34
23
18.5
5
H metres
Q = Flow rate H = Total manometric head HS = Suction height
18 22
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
37
PQA POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
RYTON, complete with threaded metallic port inserts in compliance with ISO 228/1
2
BODY PLATE
Brass
3
MOTOR BRACKET
Aluminium with brass insert (patented), reduces the risk of impeller seizure
4
IMPELLER
Brass, with peripheral radial vanes
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
MG1-12
Ø 12 mm
7
8
9
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Silicon carbide
Graphite
NBR
Pump
Model
PQA 60 PQA 70-72-80-82-90
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
PQAm 60 PQAm 70-72 PQAm 80-82 PQAm 90
10 μF 450 VL 16 μF 450 VL 20 μF 450 VL 20 μF 450 VL
25 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL
PQAm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PQA: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
1
2
38
7
4
3
7
8
6
5
9
DIMENSIONS AND WEIGHT i
f
h1
h3
h
DN1
h2
DN2
s a
MODEL
n1
m
w
n
PORTS
Single-phase
Three-phase
PQAm 60
PQA 60
PQAm 70
PQA 70
DIMENSIONS mm
DN1
DN2
½”
½”
PQAm 72
PQA 72
1”
1”
PQAm 80
PQA 80
½”
½”
PQAm 82
PQA 82
1”
1”
PQAm 90
PQA 90
½”
½”
a
f
h
25
192
145
28
258
179
h1
h2
h3
i
96
33
129
116.5
32.5
149
72.5
kg m
n
n1
w
55
118
93-100
53
s
1~
3~
4.7
4.7
9.4
8.4
9.5
8.5
9.4
8.4
121
30
151
83
116.5
32.5
149
72.5
30
151
83
9.5
8.5
35
156
76
9.5
8.5
121
90
138
112
7
62
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
VOLTAGE (three-phase)
110 V
Three-phase
230 V
400 V
240 V
415 V
PQAm 60
2.5 A
2.4 A
5.2 A
PQA 60
2.0 A
1.15 A
1.9 A
1.1 A
PQAm 70
6.2 A
5.5 A
10.8 A
PQA 70
4.2 A
2.4 A
3.7 A
2.2 A
PQAm 72
6.2 A
5.5 A
10.8 A
PQA 72
4.2 A
2.4 A
3.7 A
2.2 A
PQAm 80
6.3 A
5.5 A
10.8 A
PQA 80
4.2 A
2.4 A
3.7 A
2.2 A
PQAm 82
6.3 A
5.5 A
10.8 A
PQA 82
4.2 A
2.4 A
3.7 A
2.2 A
PQAm 90
5.6 A
5.1 A
11.5 A
PQA 90
4.2 A
2.4 A
3.8 A
2.2 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
kg
Single-phase
Three-phase
1~
PQAm 60
PQA 60
238
1240
1143
1143
306
1563
3~
PQAm 70
PQA 70
102
1280
983
881
170
2040 1622
1452
PQAm 72
PQA 72
120
1310
1160
1040
180
1900 1730
1550
PQAm 80
PQA 80
102
1280
983
881
170
2040 1622
1452
PQAm 82
PQA 82
120
1310
1160
1040
180
1900 1730
1550
PQAm 90
PQA 90
102
1280
993
891
170
2040 1639
1469
1462 1462
H
0 80
00
12
39
CP Centrifugal pumps
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their reliability and the fact that they are easy to use, these pumps are widely used in domestic and civil applications such as the distribution of water in combination with small and medium sized pressure sets, for transferring liquids and for the irrigation of gardens and allotments. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 160 l/min (9.6 m³/h) •• Head up to 56 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature up to +40 °C •• Max. working pressure:
– 6 bar for CP 100-130-132-150-158 – 10 bar for CP 170-190-200 •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
REGULATION (EU) N. 547/2012
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
40
PATENTS - TRADE MARKS - MODELS
•• Registered model CPm158 n° 0001516350 •• Registered Community Design nº 002098434 OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for CP 170, CP 170M
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
Head H (metres) 4
η = 38.5% η = 32%
η = 41%
η = 43% η = 34% η = 45.5%
η = 38%
η = 53.5%
η = 41%
Flow rate Q 4
MODEL Single-phase Three-phase CPm 100 – CPm 130 CP 130 CPm 132A CP 132A CPm 150 CP 150 CPm 158® CP 158® CPm 170 CP 170 CPm 170M CP 170M CPm 190 CP 190 – CP 200
POWER kW 0.25 0.37 0.60 0.75 0.75 1.1 1.1 1.5 2.2
HP 0.33 0.50 0.85 1 1 1.5 1.5 2 3
m³/h
0
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
l/min
0
10
20
30
40
50
60
70
80
90
100 110 120 130 140 150 160
16
15
14
12.5
11
9
7
23
22
21
20
19
18
17
15.5
14
23
–
22
21.5
21
20
19
18
17
16
14
12
9
29.5
–
29
28.5
28
26
24.5
23
21
18
15
H metres 36
34
33.5
33
41
–
–
38
36
–
–
35
34.5 33.5
48
–
–
46
44.5
56
–
–
55
54.5 53.5
Q
Q = Flow rate H = Total manometric head HS = Suction height
27.5 26.5
32.5 31.5 37
36 43
6.6
7.2
7.8
8.4
30
28.5
27
25
35
33.5
32
30
27.5
25
22
33
32
31
30
29
28
26.5
25
23
41.5
40
38
36
34.5 32.5 30.5
28
26
52
51
49.5
48
46
44.5 42.5 40.5 38.5
9.0
21
9.6
19
36
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
41
CP POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304 (cast iron for CP 170-170M-190-200)
3
IMPELLER
Stainless steel AISI 304
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
CP 100-130-132A CP 150-158 CP 170-170M-190-200
AR-12 AR-14 FN-18
Ø 12 mm Ø 14 mm Ø 18 mm
Pump
Model
CP 100-130-132A CP 150-158 CP 170-170M CP 190-200
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ 6304 ZZ / 6204 ZZ
Pump
Capacitance
6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Ceramic Graphite
Graphite Graphite Ceramic
NBR NBR NBR
Single-phase
(230 V or 240 V)
(110 V)
CPm 100 CPm 130 CPm 132A CPm 150-158 CPm 170-170M CPm 190
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL 20 μF 450 VL 25 μF 450 VL 45 μF 450 VL
25 μF 250 VL 25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL
CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CP: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
42
3
2
5
6
7
4
8
DIMENSIONS AND WEIGHT f
n
DN2
h1
DN1
h
h2
a
s
w n1
MODEL
PORTS
Single-phase
Three-phase
CPm 100 CPm 130 CPm 132A CPm 150 CPm 158® CPm 170 - 170M CPm 190 –
– CP 130 CP 132A CP 150 CP 158® CP 170 - 170M CP 190 CP 200
DN1
DIMENSIONS mm
DN2
a
f
h
253 1”
1¼”
1”
h1
205
82
h2 123
n 165
kg n1
w
135
41
42
1”
s
10 285
240
92
148
190
160
38
51
367
260
110
150
206
165
44.5
48
364
290
115
175
242
206
36.5
11
1~
3~
6.9 7.6 8.3 12.4 12.0 17.8 21.3 –
– 7.1 8.0 11.4 11.0 17.2 20.3 21.5
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
CPm 100 CPm 130 CPm 132A CPm 150 CPm 158® CPm 170 - 170M CPm 190
1.9 A 3.2 A 3.5 A 5.7 A 6.0 A 7.8 A 11.0 A
1.55 A 2.9 A 3.2 A 5.4 A 5.8 A 7.2 A 10.0 A
3.3 A 6.4 A 7.0 A 11.4 A 12.0 A 16.0 A 22.0 A
CP 130 CP 132A CP 150 CP 158® CP 170 - 170M CP 190 CP 200
2.0 A 2.9 A 4.2 A 4.4 A 5.2 A 7.5 A 9.3 A
1.2 A 1.7 A 2.4 A 2.5 A 3.0 A 4.3 A 5.4 A
1.8 A 2.4 A 4.1 A 4.3 A 5.1 A 7.3 A 9.0 A
1.1 A 1.4 A 2.4 A 2.5 A 2.9 A 4.2 A 5.2 A
PALLETIZATION MODEL
105 105 105 70 70 50 50 36 36
1280 1280 1280 1450 1450 1560 1560 1410 1410
CONTAINER kg
1~ 741 820 890 890 860 900 940 784 –
3~ – 770 860 820 790 870 910 754 794
n° pumps
H (mm)
189 189 189 112 112 70 70 54 54
2190 2190 2190 2240 2240 2120 2120 2040 2040
kg 1~ 3~ 1321 – 1460 1360 1590 1530 1410 1300 1360 1250 1250 1200 1310 1260 1166 1116 – 1186
H
0
Three-phase – CP 130 CP 132A CP 150 CP 158® CP 170 CP 170M CP 190 CP 200
H (mm)
80
Single-phase CPm 100 CPm 130 CPm 132A CPm 150 CPm 158® CPm 170 CPm 170M CPm 190 –
GROUPAGE n° pumps
00
12
43
CP Centrifugal pumps
PERFORMANCE RANGE
•• Flow rate up to 900 l/min (54 m³/h) •• Head up to 74 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 10 bar •• Continuous service S1
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their reliability and the fact that they are easy to use, these pumps are widely used in civil, agricultural and industrial applications such as for supplying water, in conditioning and cooling systems, for irrigation, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
CONSTRUCTION AND SAFETY STANDARDS
•• Registered Community Design n° 002098434 for CP 160, CP210 •• Registered Italian model n° 72753 for CP 220, CP 230, CP250
EN 60034-1 IEC 60034-1 CEI 2-3
OPTIONALS AVAILABLE ON REQUEST
REGULATION (EU) N. 547/2012
•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft for CP 220,
CERTIFICATIONS
•• Other voltages or 60 Hz frequency •• IP X5 class protection for CP 160
CP 230, CP250
COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
GUARANTEE 1 year subject to terms and conditions
44
PERFORMANCE RANGE
50 Hz n= 2900 1/min HS= 0 m
Head H (metres) 4
CP 210
CP 160
CP 250
CP 220
CP 230
Flow rate Q 4
45
CP 160-210 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
20
30
10
40
20
50
30
70
50
US g.p.m. 60
Imp g.p.m. feet
CP210A
60
200 42 46
48
49
CP210B
Head H (metres) 4
60
40
50
50
51
η = 52% 150
CP210C
51
CP160A
50
40
52
H (feet)
70
10
0
50 Hz n= 2900 1/min HS= 0 m
54
CP160B
50
56
CP160C
30
100 η = 57% 56
20 50
CP210
12 10
3
8
2
6
1
4
0 4
0
2
CP210A CP210B
3
3
CP160A CP160C
CP160B
2
1
0
5 4
CP210C
2
NPSH (feet)
14
CP160
4
P2 (HP)
Absorbed power P2 (kW)
NPSH (metres)
10
1
0
50
100
0
150
200
5
l/min
250
10
0
m³/h
15
Flow rate Q 4
MODEL Single-phase CPm 160C CPm 160B – CPm 210C – –
Three-phase CP 160C CP 160B CP 160A CP 210C CP 210B CP 210A
POWER kW 1.1 1.5 2.2 2.2 3 4
HP 1.5 2 3 3 4 5.5
Q
m³/h
0
3
4.5
6
7.5
9
10.5
12
13.2
14.4
15
16.2
16.8
l/min
0
50
75
100
125
150
175
200
220
240
250
270
280
32
31
30.5
29.5
28
26
23
20
37
36
35.5
34.5
33.5
31.5
29
26.5
23
43
42
41.5
40.5
39.5
38
35.5
33
30
26
46
45.5
44.5
43.5
42
40
37.5
34.5
32
28.5
54
53
52
51
49.5
48
45.5
43
40
38.5
37
34
61
61
60
59
57.5
56
53.5
51
49
46.5
45
42
H metres
Q = Flow rate H = Total manometric head HS = Suction height
46
27 40
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
CP 220 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
CP220AH CP220A
η
Head H (metres) 4
59
H (feet)
CP220B
Absorbed power P2 (kW)
NPSH (feet)
NPSH (metres)
CP220C
AH
P2 (HP)
A
B C
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
3
6
12
18
24
27
l/min
0
50
100
200
300
400
450
CPm 220C
CP 220C
2.2
3
32
31.5
31
30
28
24
21
–
CP 220B
3
4
38
37.5
37
36
33.5
29
25
–
CP 220A
4
5.5
49
48.5
48
46
43.5
39.5
36
–
CP 220AH
5.5
7.5
52
51.5
51
49
47
44
42
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
47
CP 230 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
64
Head H (metres) 4
η = 65%
P2 (HP)
Absorbed power P2 (kW)
NPSH (feet)
NPSH (metres)
H (feet)
64
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
CP 230C
3
4
CP 230B
4
5.5
CP 230A
5.5
7.5
Q
m³/h
0
6
12
18
24
30
36
42
48
51
54
l/min
0
100
200
300
400
500
600
700
800
850
900
30
29.5
28.5
27
25
22
19.5
15.5
11.5
9
39
38.5
38
36
34
31
28
24
18.5
15
13
46
45.5
44.5
42
40
37
32.5
27.5
21.5
18
15
H metres
Q = Flow rate H = Total manometric head HS = Suction height
48
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
CP 250 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
46 51
Head H (metres) 4
52
H (feet)
η = 54% 52
P2 (HP)
Absorbed power P2 (kW)
NPSH (feet)
NPSH (metres)
51
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
CP 250C
7.5
10
CP 250A
11
15
Q
m³/h
0
6
12
18
24
30
36
42
48
54
l/min
0
100
200
300
400
500
600
700
800
900
57
56
54.5
52.5
49.5
46
41.5
35.5
30
24
74
73
71
68
65
61
57
51
45
37
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
49
CP 160-210 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Cast iron
3
IMPELLER
Brass
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
CP 160 CP 210
FN-18 FN-24
Ø 18 mm Ø 24 mm
Pump
Model
CP 160 CP 210
6204 ZZ / 6204 ZZ 6206 ZZ - C3 / 6205 ZZ
Pump
Capacitance
6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Graphite Graphite
Ceramic Ceramic
NBR NBR
Single-phase
(230 V or 240 V)
(110 V)
CPm 160C CPm 160B CPm 210C
31.5 μF 450 VL 45 μF 450 VL 70 μF 450 VL
60 μF 250 VL 80 μF 250 VL –
CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding (up to 1.5 kW). CP: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
50
3
2
7
5
4
8
6
DIMENSIONS AND WEIGHT f
n
DN2
h1
DN1
h
h2
a
s
w n1
MODEL
PORTS
Single-phase
Three-phase
CPm 160C
CP 160C
CPm 160B
CP 160B
–
CP 160A
CPm 210C
CP 210C
–
CP 210B
–
CP 210A
DN1
DIMENSIONS mm
DN2
a
f
54 1½”
h
373
h1
260
h2
110
150
n
207
kg n1
w
165
s
44.5
11
1” 60
402
305
125
180
252
210
39.5
11
1~
3~
19.7
17.7
21.0
21.0
–
21.0
26.0
27.5
–
30.0
–
32.0
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
CPm 160C
8.6 A
7.8 A
17.0 A
CP 160C
5.7 A
3.3 A
1.9 A
5.2 A
3.0 A
1.7 A
CPm 160B
10.3 A
9.8 A
21.0 A
CP 160B
7.3 A
4.2 A
2.4 A
6.7 A
3.9 A
2.3 A
CPm 210C
13.0 A
12.7 A
–
CP 160A
8.9 A
5.1 A
3.0 A
8.3 A
4.8 A
2.8 A
CP 210C
9.2 A
5.3 A
3.1 A
8.8 A
5.1 A
2.9 A
CP 210B
11.2 A
6.5 A
3.8 A
10.8 A
6.2 A
3.6 A
CP 210A
14.8 A
8.5 A
4.9 A
14.2 A
8.2 A
4.7 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
1~
CP 160C
50
1555
CP 160B
50
1555
–
CP 160A
50
CPm 210C
CP 210C
18
Single-phase
Three-phase
CPm 160C CPm 160B
CONTAINER kg
kg
3~
n° pumps
H (mm)
1~
3~
1009
909
70
2121
1403
1263
1074
1074
70
2121
1494 1494
1555
–
1074
70
2121
–
1494
1205
492
520
–
–
–
–
CP 210B
18
1205
–
564
–
–
–
–
CP 210A
18
1205
–
600
–
–
–
–
0 80
– –
H
00
12
51
CP 220-230-250 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Cast iron
3
IMPELLER
Brass for CP 220, CP 230 Cast iron for CP 250
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
FN-20
CP 220C-B CP 230C CP 220A-AH CP 230B-A CP 250C CP 250A 6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ø 20 mm
Graphite
Ceramic
NBR
FN-24
Ø 24 mm
Graphite
Ceramic
NBR
FN-32 NU
Ø 32 mm
Graphite
Ceramic
NBR
Pump
Model
CP 220C CPm 220C CP 220B CP 230C CP 220A-AH CP 230B-A CP 250C CP 250A
6206 ZZ - C3 / 6204 ZZ
Pump
Capacitance
6206 ZZ - C3 / 6205 ZZ 6307 ZZ - C3 / 6206 ZZ - C3 6310 ZZ - C3 / 6308 ZZ - C3
Single-phase
(230 V or 240 V)
CPm 220C
70 μF 450 VL
CPm: single-phase 230 V - 50 Hz. CP: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 11 kW. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X5.
6
1
52
3
2
7
5
4
8
6
DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w
n2
MODEL Single-phase
Three-phase
CPm 220C – – – – – – – –
CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250A
s
n1
PORTS DN1
DN2
DIMENSIONS mm a
f
70 2”
h
441/409 441 460 505 441 460 505 507 571
2”
65
h1
h2
n
kg n1
n2
315
132
183
255
170
230
328
136
192
273
190
250
315
132
183
255
170
230
328
136
192
273
190
250
392
160
232
322
230
294
w
s
1~
3~
14
31.9 – – – – – – – –
28.5 32.3 41.0 46.0 31.9 41.0 46.0 74.0 103.0
40
45
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
Three-phase
230 V
400 V
690 V
240 V
415 V
CPm 220C
15.8 A
15.0 A
CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250A
11.4 A 12.6 A 17.0 A 20.0 A 13.2 A 16.8 A 20.0 A 28.6 A 40.8 A
6.6 A 3.8 A 7.3 A 4.2 A 9.8 A 5.7 A 11.5 A 6.7 A 7.6 A 4.4 A 9.7 A 5.6 A 11.5A 6.7 A 16.5 A 9.5 A 23.6 A 13.7 A
10.7 A 12.0 A 16.5 A 21.0 A 11.1 A 16.2 A 19.2 A 27.5 A 40.8 A
6.2 A 3.6 A 7.0 A 4.0 A 9.5 A 5.5 A 12.0 A 6.9 A 6.4 A 3.7 A 9.4 A 5.4A 11.0 A 6.4 A 16.0 A 9.3 A 23.6 A 13.7 A
720 V
PALLETIZATION MODEL Three-phase CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250A
H (mm)
18 18 18 12 18 18 12 6 6
1220 1180 1430 1430 1200 1430 1430 1180 1180
CONTAINER kg
1~ 598 – – – – – – – –
3~ 530 608 760 570 598 760 570 460 640
n° pumps
H (mm)
24 24 24 16 24 24 16 – –
1580 1520 1860 1860 1550 1860 1860 – –
kg 1~ 790 – – – – – – – –
3~ 700 800 1000 760 790 1000 760 – –
H
0 80
Single-phase CPm 220C – – – – – – – –
GROUPAGE n° pumps
00
12
53
AL-RED Stainless steel centrifugal pump
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their construction characteristics, these centrifugal pumps are suitable for use in the domestic, agricultural and industrial sectors. All of the components in contact with the pumped liquid are constructed from stainless steel AISI 304, thus guaranteeing complete hygiene and maximum resistance against corrosion. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Maximum flow rate 160 l/min (9.6 m³/h) •• Maximum head 23 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 4 bar •• Continuous service S1
OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 REGULATION (EU) N. 547/2012
•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
54
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
25
10
50 Hz n= 2900 1/min HS= 0 m
20
0
30
10
40
20
US g.p.m.
30
Imp g.p.m. feet 80
70
AL-RED135
20 60
Head H (metres) 4
47
η = 48%
15
50 44.5
40
10 30
20
5
0
25
0
1
50 2
75
3
4
100 5
125
6
7
150 8
l/min
9
10
m³/h
Flow rate Q 4
MODEL
POWER
Single-phase
Three-phase
kW
HP
AL-RED 135m
AL-RED 135
0.75
1
Q
m³/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
l/min
0
20
40
60
80
100
120
140
160
23
21
20.5
20
18.5
17
15
13
10
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
55
AL-RED POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-14
Ø 14 mm
6
BEARINGS
6203 ZZ / 6203 ZZ
7
CAPACITOR
Capacitance
8
ELECTRIC MOTOR
Materials
(230 V or 240 V)
(110 V)
20 μF 450 VL
60 μF 300 VL
Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
AL-RED 135m: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. AL-RED 135: three-phase 230/400 V - 50 Hz. ➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
1
56
3
6
5
7
4
8
6
DIMENSIONS AND WEIGHT f
n
a
h1
h3
h
DN1
h2
DN2
s w
MODEL
n1
PORTS
DIMENSIONS mm
kg
Single-phase
Three-phase
DN1
DN2
a
f
h
h1
h2
h3
n
n1
w
s
1~
3~
AL-RED 135m
AL-RED 135
1¼”
1”
31
296
206
97
103
200
186
135
73.5
10
9.1
9.0
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
AL-RED 135m
5.0 A
4.8 A
10.0 A
AL-RED 135
3.1 A
1.8 A
1.0 A
3.0 A
1.7 A
1.0 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
Single-phase
Three-phase
n° pumps
H (mm)
1~
3~
n° pumps
AL-RED 135m
AL-RED 135
70
1450
661
654
112
H (mm)
kg 1~
2240 1043
3~ 1032
H
0 80
00
12
57
HF Centrifugal pumps ➠ Medium flow rates
PERFORMANCE RANGE
•• Flow rate up to 600 l/min (36 m³/h) •• Head up to 39 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature up to +40 °C •• Max. working pressure:
– 6 bar for HF 5-50-51 – 10 bar for HF 5M-70 •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 REGULATION (EU) N. 547/2012
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
58
INSTALLATION AND USE Suitable for use in civil and agricultural applications. The high efficiency and continuous duty capabilities makes these pumps ideal for use in activities such as flood and spray irrigation, drawing water from lakes, rivers and wells, or for any number of different industrial applications where the characteristics of high flow rates and mid to low head are required. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for HF 70, HF 5BM, HF 5AM
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
HF70A
HF70B
Head H (metres) 4
HF70C
η = 60%
HF5AM HF51A
HF5BM
HF51B η = 70% η = 63%
HF5A HF5B HF5C
HF50A HF50B
η = 74%
η = 67%
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
3
6
9
12
15
18
21
24
30
36
l/min
0
50
100
150
200
250
300
350
400
500
600
HFm 50B
HF 50B
0.37
0.50
10
10
9.5
8.5
7.5
6
4
HFm 50A
HF 50A
0.55
0.75
12
12
11.5
11
9.6
8
6
HFm 51B
HF 51B
0.60
0.85
18.2
17.2
16
14
11.5
9
5.4
HFm 51A
HF 51A
0.75
1
21.2
20.2
19
17
14.5
11.6
8.4
HFm 70C
HF 70C
1.1
1.5
29
28
26.5
24.5
22
18.5
15
HFm 70B
HF 70B
1.5
2
33
32
30.5
28.5
26
22.5
19
–
HF 70A
2.2
3
39
38
36.5
34.5
32
28.5
25
HFm 5C
HF 5C
0.60
0.85
12.5
–
12
11.7
11
10.2
9.2
8
6.5
HFm 5B
HF 5B
0.75
1
13.7
–
13.2
13
12.5
11.6
10.5
9.2
8
5
HFm 5A
HF 5A
1.1
1.5
14.5
–
13.8
13.5
13.2
12.6
11.8
10.5
9.2
6.5
HFm 5BM
HF 5BM
1.1
1.5
20.2
–
19.2
19
18
17
16
14
12
7.5
HFm 5AM
HF 5AM
1.5
2
22.5
–
22
21.5
21
20
18.5
16.6
14.5
10
H metres
Q = Flow rate H = Total manometric head HS = Suction height
3
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
59
HF POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304 (cast iron for HF 70-5M)
3
IMPELLER
Brass
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
HF 50 HF 5-51 HF 5M-70
AR-12 AR-14 FN-18
Ø 12 mm Ø 14 mm Ø 18 mm
Pump
Model
HF 50 HF 5-51 HF 5M-70
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM
10 μF 450 VL 14 μF 450 VL 20 μF 450 VL 20 μF 450 VL 25 μF 450 VL 45 μF 450 VL 16 μF 450 VL 20 μF 450 VL 25 μF 450 VL 25 μF 450 VL 45 μF 450 VL
25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL 60 μF 300 VL 60 μF 300 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL
6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Ceramic Graphite
Graphite Graphite Ceramic
NBR NBR NBR
HFm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. HF: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
6
7
1
3
4
60
5
8
6
DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w
MODEL
PORTS
Single-phase
Three-phase
HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B – HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM
HF 50B HF 50A HF 51B HF 51A HF 70C HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM
s
n1
DN1
DN2
DIMENSIONS mm a
f
h
h1
h2
n
kg n1
w
s
42
265
200
82
118
166
135
-3
45
300
225
92
133
190
160
4
48.5
373
269
114
155
216
171
12
12
43
316
238
97
141
192
-68
10
1
11
10 1½”
2”
1½”
2”
160 51
386
260
110
150
206
1~
3~
8.1 8.7 12.9 13.0 19.0 21.8 – 14.5 14.5 15.3 19.5 22.0
7.6 8.3 11.9 12.0 18.6 20.5 21.9 13.3 13.3 14.9 18.9 20.9
ABSORPTION MODEL
VOLTAGE (single-phase)
VOLTAGE (three-phase)
MODEL
Single-phase
230 V
240 V
110 V
Three-phase
HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM
2.8 A 3.8 A 4.7 A 5.6 A 8.0 A 10.0 A 4.2 A 4.9 A 6.2 A 7.7 A 9.8 A
2.6 A 3.5 A 4.6 A 5.3 A 7.6 A 9.0 A 3.8 A 4.5 A 5.7 A 7.1 A 9.0 A
5.6 A 7.6 A 9.2 A 11.2 A 16.0 A 20.0 A 8.4 A 10.0 A 12.5 A 14.8 A 19.6 A
HF 50B HF 50A HF 51B HF 51A HF 70C HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM
230 V 2.1 A 3.0 A 3.6 A 4.4 A 5.7 A 7.4 A 9.5 A 3.5 A 3.6 A 5.0 A 5.7 A 7.1 A
400 V 1.2 A 1.7 A 2.1 A 2.5 A 3.3 A 4.3 A 5.5 A 2.0 A 2.1 A 2.9 A 3.3 A 4.1 A
690 V 0.7 A 1.0 A 1.2 A 1.5 A 1.9 A 2.5 A 3.2 A 1.15 A 1.2 A 1.7 A 1.9 A 2.4 A
240 V 2.1 A 3.0 A 3.8 A 4.0 A 5.5 A 7.1 A 9.1 A 3.3 A 3.5 A 4.8 A 5.5 A 6.5 A
415 V 720 V 1.2 A 0.7 A 1.75 A 1.0 A 2.2 A 1.3 A 2.3 A 1.3 A 3.2 A 1.8 A 4.1 A 2.4 A 5.3 A 3.1 A 1.9 A 1.1 A 2.0 A 1.2 A 2.8 A 1.6 A 3.2 A 1.8 A 3.7 A 2.1 A
PALLETIZATION MODEL Three-phase HF 50B HF 50A HF 51B HF 51A HF 70C HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM
n° pumps 75 75 70 70 36 36 36 60 60 60 50 50
kg H (mm) 1~ 3~ 1290 630 590 1290 670 640 1430 920 850 1430 930 860 1470 700 690 1470 800 760 1470 – 810 1540 890 820 1540 890 820 1540 940 910 1540 990 960 1540 1120 1060
CONTAINER n° pumps 135 135 112 112 54 54 54 84 84 84 70 70
H (mm) 2210 2210 2200 2200 2130 2130 2130 2100 2100 2100 2100 2100
kg 1~ 3~ 1110 1050 1190 1140 1460 1350 1480 1360 1050 1020 1200 1130 – 1200 1240 1140 1240 1140 1300 1270 1380 1340 1560 1480
H
0 80
Single-phase HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B – HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM
GROUPAGE
00
12
61
HF Centrifugal pumps ➠ High flow rates
PERFORMANCE RANGE
•• Flow rate up to 2200 l/min (132 m³/h) •• Head up to 24.5 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature up to +40 °C •• Max. working pressure:
– 6 bar for HF 4 – 10 bar for HF 6-8-20-30 •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 REGULATION (EU) N. 547/2012
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
62
INSTALLATION AND USE Suitable for use in civil and agricultural applications. The high efficiency and continuous duty capabilities makes these pumps ideal for use in activities such as flood and spray irrigation, drawing water from lakes, rivers and wells, or for any number of different industrial applications where the characteristics of high flow rates and mid to low head are required. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz
n= 2900 1/min
HS= 0 m
HF8A HF30A η = 78%
HF8B
HF6A
HF20A
HF30B
HF8C
η = 70%
Head H (metres)
η = 77%
HF20B HF6B
η = 77%
HF20C HF6C
HF4
η = 73%
Flow rate Q
MODEL
POWER
Single-phase Three-phase kW HP HFm 4
HF 4
0.75
HFm 6C HFm 6B –
HF 6C HF 6B HF 6A
1.1 1.5 1.5 2 2.2 3
HFm 8C
–
2.2
3
–
HF 8B
3
4
–
HF 8A
4
5.5
HFm 20C
–
2.2
3
Q
m³/h
0
l/min
0
200 300 400 500 600 700 800 900 1000 1100 1200 1400 1600 1700 1800 2000 2200
10
9.3
1
12
18 8.7
24 8
30 7
36 6
11.9 11.7 11.3 10.7 10.2 9.2 14.7 14.5
H metres
14
42
48
54
60
4.7
3
8
6.7
5
3
8.2
6.7
66
13.5 12.8
12
11
9.7
18.5 18.1 17.8 17.2 16.8
16
15
13.8 12.2 10.5 8.3
17
17
16.9 16.8 16.5 15.5 14.5 13.5 11.8
21.5
21
20.7
24.5
24
12.5
-
20
19.5 18.8 17.8 16.5
23.5
23
22.5 21.8 20.8 19.5 18.3 16.8
-
12.5
12
11.5 10.5 9.8
15
10
8.1
84
8
108
120
132
6 9
15
13
7.2
6.3
13
12
4.3
2
9
4.8
2
12
7.8
5
2
15
14.5
13
21.5
21
19.5
–
HF 20B
3
4
16
-
-
15.5 15.4 15.3 15.2
15
14.5
14
HF 20A
4
5.5
19
-
-
18.5 18.4 18.3 18.2
18
17.5
17
–
HF 30B
5.5 7.5
18
-
-
-
-
18
18
18
18
18
17.5
–
HF 30A
7.5
23
-
-
-
-
23
23
23
23
23
22.5 22.5 22.5
Q = Flow rate H = Total manometric head HS = Suction height
102
6
–
10
96
5
13.5 11.2
9
72
16.2 15.2 17
16.5 15.5 22
18
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
63
HF POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Cast iron (stainless steel AISI 304 for HF 4)
3
IMPELLER
Brass for HF 4, HF 6, HF 8, HF 20 Cast iron for HF 30
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
HF 4 HF 6 HF 8-20 HF 30
AR-14 FN-18 FN-20 FN-24
Ø 14 mm Ø 18 mm Ø 20 mm Ø 24 mm
Pump
Model
HF 4 HF 6 HFm 8C-20C HF 8B-20B HFm 8B-20B HF 8A-20A HF 30
6203 ZZ / 6203 ZZ 6304 ZZ / 6204 ZZ
Pump
Capacitance
6
7
8
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Graphite Graphite Graphite
Graphite Ceramic Ceramic Ceramic
NBR NBR NBR NBR
6206 ZZ - C3 / 6205 ZZ 6306 ZZ - C3 / 6206 ZZ - C3 6307 ZZ - C3 / 6206 ZZ - C3
Single-phase
(230 V or 240 V)
(110 V)
HFm 4 HFm 6C HFm 6B HFm 8C HFm 8B HFm 20C HFm 20B
20 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL 70 μF 450 VL 60 μF 450 VL 70 μF 450 VL 60 μF 450 VL
60 μF 300 VL 60 μF 250 VL 80 μF 250 VL – – – –
HFm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding (up to 1.5 kW). HF: three-phase 230/400 V - 50 Hz up to 4 kW, 400/690 V - 50 Hz from 5.5 to 7.5 kW ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
6
7
1
3
4
64
5
8
6
DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w
s
n1
MODEL
PORTS
DIMENSIONS mm
kg
Single-phase
Three-phase
DN1
DN2
a
f
h
h1
h2
n
n1
w
s
1~
3~
HFm 4 HFm 6C HFm 6B – HFm 8C HFm 8B – HFm 20C HFm 20B – – –
HF 4 HF 6C HF 6B HF 6A
2½”
2½”
47
317
240
97
143
198
155
-68
10
3”
3”
68
411
120
192
240
6
12
80
445 465/445 465 450 465/450 465
30
14
14.5 25.5 26.5 – 35.0 40.0 – 35.0 40.0 – – –
13.2 24.2 25.5 26.7 – 35.0 40.0 – 35.0 40.0 60.9 65.2
–
HF 8B HF 8A –
4”
HF 20B HF 20A HF 30B HF 30A
4”
82
585
312
190 132
370
160
180
210
245
292
212
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
Single-phase
230 V
240 V
110 V
HFm 4
5.9 A
5.3 A
11.8 A
HFm 6C
8.8 A
8.0 A
17.6 A
HFm 6B
10.8 A
9.8 A
21.6 A
HFm 8C
15.0 A
14.5 A
–
HFm 8B
20.0 A
19.0 A
–
HFm 20C
14.5 A
14.0 A
–
HFm 20B
20.0 A
19.0 A
–
Three-phase HF 4 HF 6C HF 6B HF 6A HF 8B HF 8A HF 20B HF 20A HF 30B HF 30A
VOLTAGE (three-phase) 230 V 400 V 4.3 A 2.5 A 6.2 A 3.6 A 8.0 A 4.6 A 9.0 A 5.2 A 11.8 A 6.8 A 15.8 A 9.1 A 13.0 A 7.5 A 15.2 A 8.8 A 21.3 A 12.3 A 28.6 A 16.5 A
690 V 1.4 A 2.1 A 2.7 A 3.0 A 3.9 A 5.3 A 4.3 A 5.1 A 7.1 A 9.5 A
240 V 415 V 4.0 A 2.3 A 6.0 A 3.5 A 7.4 A 4.3 A 8.3 A 4.8 A 12.1 A 7.0 A 15.2 A 8.8 A 13.4 A 7.7 A 15.3 A 8.8 A 20.4 A 11.8 A 27.5 A 15.9 A
720 V 1.3 A 2.0 A 2.5 A 2.8 A 4.0 A 5.1 A 4.4 A 5.1 A 6.8 A 9.2 A
PALLETIZATION MODEL Three-phase HF 4 HF 6C HF 6B HF 6A HF 8B HF 8A HF 20B HF 20A HF 30B HF 30A
n° pumps 60 36 36 36 18 18 18 18 12 12
H (mm) 1540 1480 1480 1480 1430 1430 1430 1430 1570 1570
CONTAINER kg
1~ 890 940 970 – – – – – – –
3~ 830 890 940 980 650 740 650 740 750 800
n° pumps 84 54 54 54 24 24 24 24 16 16
kg H (mm) 1~ 3~ 2100 1240 1150 2150 1400 1330 2150 1450 1400 2150 – 1460 1860 – 860 1860 – 980 1860 – 860 1860 – 980 2040 – 990 2040 – 1060
H
0 80
Single-phase HFm 4 HFm 6C HFm 6B – HFm 8C HFm 8B HFm 20C HFm 20B – –
GROUPAGE
00
12
65
NGA Centrifugal pumps with open impeller
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with liquids that are not chemically aggressive towards the materials from which the pump is made. The open impeller design allows liquids containing relatively high levels of impurities to be pumped without the risk of the impeller clogging. As a result of these characteristics the NGA series pumps are used specifically in industry and for transferring water from canals, rivers, reservoirs, tanks, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 350 l/min (21 m³/h) •• Head up to 20 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C
(up to +40 for the version with the technopolymer impeller)
•• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 6 bar •• Passage of suspended solids up to Ø 10 mm •• Continuous service S1
OPTIONALS AVAILABLE ON REQUEST
CONSTRUCTION AND SAFETY STANDARDS
•• Pump with technopolymer impeller •• Special mechanical seal •• Other voltages or 60 Hz frequency
EN 60034-1 IEC 60034-1 CEI 2-3
GUARANTEE
REGULATION (EU) N. 547/2012
1 year subject to terms and conditions
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
66
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
NGA1A
Head H (metres) 4
NGA1B
η = 65%
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
NGAm 1B
NGA 1B
0.55
0.75
NGAm 1A
NGA 1A
0.75
1
Q
m³/h
0
3
6
9
12
15
18
19.5
21
l/min
0
50
100
150
200
250
300
325
350
18
17
16
14.5
13
10.5
8
6
20
19.5
18
16.5
15
12.5
10
8
H metres
Q = Flow rate H = Total manometric head HS = Suction height
6
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
67
NGA POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
IMPELLER
Open impeller in stainless steel 316
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-14
Ø 14 mm
6
BEARINGS
6203 ZZ / 6203 ZZ
7
CAPACITOR
Pump
8
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
NGAm 1B NGAm 1A
16 μF 450 VL 20 μF 450 VL
60 μF 300 VL 60 μF 300 VL
NGAm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. NGA: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
7
2
1
3
68
5
4
8
6
DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w
MODEL
PORTS
Single-phase
Three-phase
NGAm 1B
NGA 1B
NGAm 1A
NGA 1A
s
n1
DIMENSIONS mm
kg
DN1
DN2
a
f
h
h1
h2
n
n1
w
s
1½”
1½”
41
297
227
92
135
190
160
50
10
1~
3~
12.7
11.8
12.8
11.9
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
NGAm 1B
5.6 A
5.3 A
NGAm 1A
6.2 A
6.0 A
MODEL 110 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
11.2 A
NGA 1B
3.3 A
12.0 A
NGA 1A
3.7 A
720 V
1.9 A
1.1 A
3.2 A
1.85 A
1.1 A
2.1 A
1.2 A
3.7 A
2.1 A
1.2 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
NGA 1B
70
NGA 1A
70
Single-phase
Three-phase
NGAm 1B NGAm 1A
CONTAINER kg
n° pumps
H (mm)
kg
1~
3~
1~
1415
910
840
112
2180 1440 1340
1415
920
850
112
2180
1450
3~ H
1350
0
80
00
12
69
NGA-PRO Stainless steel pumps with open impeller
PERFORMANCE RANGE
•• Flow rate up to 350 l/min (21 m³/h) •• Head up to 20 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 6 bar •• Passage of suspended solids up to Ø 10 mm •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The open impeller design allows liquids containing relatively high levels of impurities to be pumped without the risk of the impeller clogging. All of the components in contact with the pumped liquid are constructed in stainless steel AISI 316. As a result of these characteristics the NGA-PRO series pumps find specific use in assemblies for washing fruit, vegetables, fish and shellfish, in industrial assemblies for washing metallic objects and glass containers, as well as for the circulation of cooling liquids. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency
REGULATION (EU) N. 547/2012
GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
70
1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
NGA1A-PRO
Head H (metres) 4
NGA1B-PRO
η = 67%
Flow rate Q 4
MODEL
POWER kW
HP
NGAm 1B - PRO NGA 1B - PRO
0.55
0.75
NGAm 1A - PRO NGA 1A - PRO
0.75
1
Single-phase
Three-phase
Q = Flow rate H = Total manometric head HS = Suction height
Q
m³/h
0
3
6
9
12
15
18
19.5
21
l/min
0
50
100
150
200
250
300
325
350
18
17
16
14.5
13
10.5
8
6
20
19.5
18
16.5
15
12.5
10
8
H metres
6
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
71
NGA-PRO POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 316, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 316
3
IMPELLER
Open impeller in stainless steel 316
4
MOTOR SHAFT
Stainless steel AISI 316
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-14S
Ø 14 mm
6
BEARINGS
6203 ZZ / 6203 ZZ
7
CAPACITOR
Pump
8
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
Viton
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
NGAm 1B - PRO NGAm 1A - PRO
16 μF 450 VL 20 μF 450 VL
60 μF 300 VL 60 μF 300 VL
NGAm - PRO: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. NGA - PRO: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
7
2
1
3
72
5
4
8
6
DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w
MODEL Single-phase
PORTS
Three-phase
NGAm 1B - PRO
NGA 1B - PRO
NGAm 1A - PRO
NGA 1A - PRO
s
n1
DIMENSIONS mm
kg
DN1
DN2
a
f
h
h1
h2
n
n1
w
s
1½”
1½”
41
297
227
92
135
190
160
50
10
1~
3~
13.0
11.9
13.1
12.0
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
NGAm 1B - PRO
5.6 A
5.3 A
NGAm 1A - PRO
6.2 A
6.0 A
MODEL 110 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
11.2 A
NGA 1B - PRO
3.3 A
12.0 A
NGA 1A - PRO
3.6 A
720 V
1.9 A
1.1 A
3.2 A
1.85 A
1.1 A
2.1 A
1.2 A
3.5 A
2.0 A
1.2 A
PALLETIZATION MODEL Single-phase
Three-phase
GROUPAGE n° pumps
H (mm)
CONTAINER kg
1~
3~
n° pumps
H (mm)
kg 1~
NGAm 1B - PRO
NGA 1B - PRO
70
1415
930
850
112
2180 1480
NGAm 1A - PRO
NGA 1A - PRO
70
1415
940
860
112
2180
3~ 1350
H
1490 1360
0
80
00
12
73
2CP Twin-impeller pumps
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The high efficiency and adaptability of these pumps to even the most unusual of applications, makes them ideal for use in the domestic, civil and industrial sectors; in particular for the distribution of water in combination with pressure sets, for pressure boosting and in fire-fighting sets. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 450 l/min (27 m³/h) •• Head up to 112 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 10 bar
(6 bar for 2CP25/130N) •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IPX5 class protection for:
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS
GUARANTEE
COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
1 year subject to terms and conditions
74
– 2CP32/200, – 2CP32/210,
– 2CP40/180, – 2CP40/200
50 Hz n= 2900 1/min HS= 0 m
Head H (metres) 4
PERFORMANCE RANGE
2CP25/14 2CP25/130N
2CP25/16
2CP32/210 2CP32/200
2CP40/180
2CP40/200
Flow rate Q 4
75
2CP CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
2CP25/14A
30
2CP25/14B
37
H (feet)
35
2CP25/130N 37
7 6 5 4 3 2 1 0
2CP25/14
20
2CP25/130N
15 10 5
NPSH (feet)
Head H (metres) 4
η = 36%
0
2CP25/14A
Absorbed power P2 (kW)
NPSH (metres)
35
P2 (HP)
2CP25/14B
2CP25/130N
Flow rate Q 4
MODEL Single-phase
POWER kW
HP
0.75
1
2CP 25/14B
1.1
1.5
2CP 25/14A
1.5
2
Three-phase
2CPm 25/130N
2CP 25/130N
2CPm 25/14B 2CPm 25/14A
Q = Flow rate H = Total manometric head HS = Suction height
76
Q
m³/h l/min
H metres
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
0
20
30
40
50
42
39
37
34
31
60
70
80
90
100
28.5
25.5
22
18
15
54
52
50
47.5
44,5
41
37
67
65
62
60
57
54
50
33
28
22
45
40
32
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
80
5
0
10 5
15
50 Hz n= 2900 1/min HS= 0 m
20
10
25
15
30
20
35
25
40
45US g.p.m.
30
35
Imp g.p.m. feet
70
2CP25/16A 35
60
40
2CP25/16B
42
50
η = 44%
2CP25/16C
43
H (feet)
Head H (metres) 4
43
42
40
30
20
10
C
NPSH (feet)
4
A
B
3 2 1 0 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4
A
B
P2 (HP)
Absorbed power P2 (kW)
NPSH (metres)
0 5
C
0
20
0
1
40 2
60
80
3
4
100 5
120
6
140
7
160
8
9
l/min 10
m³/h
Flow rate Q 4
MODEL Single-phase
Three-phase
POWER kW
HP
1.1
1.5
2CPm 25/16C
2CP 25/16C
2CPm 25/16B
2CP 25/16B
1.5
2CP 25/16A
2.2
–
Q = Flow rate H = Total manometric head HS = Suction height
Q
m³/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
100 110 120 140 160
0
20
30
40
50
60
70
80
90
47
46
45
44
42
40
38
35
33
2
H metres 58
56
55
54
3
68
67
l/min
65.5 64.5
6.6
30
27
7.2
8.4
9.6
24
53
51
49
47
45
43
40
37
30
63
62
60
58
56
54
51
48
41
32
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
77
2CP CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
2CP32/200B
NPSH (feet)
NPSH (metres)
H (feet)
Head H (metres) 4
2CP32/200C
Absorbed power P2 (kW)
B
P2 (HP)
C
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
2CP 32/200C
3
4
2CP 32/200B
4
5.5
Q
m³/h l/min
H metres
0
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.5
8.4
9.6
10.8
12.0
15.0
0
40
50
60
70
80
90
100
110
125
140
160
180
200
250
70
66.5
65.5
65
64
63
62
60.5
59
57
55
52
49.5
46.5
36
85
81
80
79
78
77
76
75
74
72
69
66
62
58
49
Q = Flow rate H = Total manometric head HS = Suction height
78
2.4
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
2CP32/210A
NPSH (feet)
NPSH (metres)
H (feet)
Head H (metres) 4
2CP32/210B
Absorbed power P2 (kW)
A
P2 (HP)
B
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
2CP 32/210B
5.5
7.5
2CP 32/210A
7.5
10
Q
m³/h l/min
H metres
0
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.5
8.4
9.6
10.8
12.0
15.0
0
40
50
60
70
80
90
100
110
125
140
160
180
200
250
94
94
93.5
93
92
91
90
89
87
85
83
79
75
70
56
112
111
110.8 110.5 110.3
110
109
108
107
105
102
99
94
89
74
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
79
2CP CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
2CP40/180A
Head H (metres) 4
2CP40/180B
Absorbed power P2 (kW)
C
NPSH (feet)
NPSH (metres)
H (feet)
2CP40/180C
A-B
A
P2 (HP)
B C
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
2CP 40/180C
4
5.5
2CP 40/180B
5.5
7.5
2CP 40/180A
7.5
10
Q
m³/h l/min
H metres
0
6.0
6.6
7.5
8.4
9.6
10.8
0
100
110
125
140
160
64
62
61
60
59
58
15.0
18.0
21.0
24.0
180
200
250
300
350
400
56
54.5
49
43
35
76
73
72.5
72
71
70
69
67.5
64
59.5
54
46
88
85
84.5
84
83
82
81
79.5
76
72
67
60
Q = Flow rate H = Total manometric head HS = Suction height
80
12.0
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
110 350
2CP40/200A
100
300
90
H (feet)
Head H (metres) 4
2CP40/200B
80
70
60
25
6
20 15
4
10
2
5
Absorbed power P2 (kW)
0 11
NPSH (feet)
8
0 14
A
10
13
B
9
12 11
8
10
7
P2 (HP)
NPSH (metres)
50
9
6
8
5
7
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
2CP 40/200B
9.2
12.5
2CP 40/200A
11
15
Q
m³/h l/min
H metres
0
6.0
9
10.8
12.0
15.0
18.0
21.0
24.0
27.0
0
100
150
180
200
250
300
350
400
450
97
94
92
90
88
85
80
74
68
61
105
102
100
98
97
93
88
83
76
69
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
81
2CP 25/130N POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
IMPELLERS
Stainless steel AISI 304
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-14
Ø 14 mm
6
BEARINGS
6203 ZZ / 6203 ZZ
7
CAPACITOR
Pump
8
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
2CPm 25/130N
20 μF 450 VL
60 μF 300 VL
2CPm 25/130N: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2CP 25/130N: three-phase 230/400 V - 50 Hz. ➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
7
1
3
82
2
5
4
8
6
DIMENSIONS AND WEIGHT
f
n
a
h1
h
DN1
h2
DN2
w
s n1
MODEL
PORTS
DIMENSIONS mm
kg
Single-phase
Three-phase
DN1
DN2
a
f
h
h1
h2
n
n1
w
s
1~
3~
2CPm 25/130N
2CP 25/130N
1¼”
1”
73
330
201
92
109
180
142
1
10
14.5
14.0
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
2CPm 25/130N
6.3 A
6.0 A
12.6 A
2CP 25/130N
4.6 A
2.6 A
1.5 A
4.3 A
2.5 A
1.5 A
PALLETIZATION MODEL Single-phase
Three-phase
2CPm 25/130N 2CP 25/130N
GROUPAGE
CONTAINER kg
kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
1~
3~
60
1320
890
860
84
1790
1240
1200
H
0
80
00
12
83
2CP POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
IMPELLERS
Brass
3
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
4
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
FN-18
2CP 25/14 2CP 25/16 2CP 32/200 2CP 32/210 2CP 40/180 2CP 40/200 5
BEARINGS
Pump
CAPACITOR
ELECTRIC MOTOR
Elastomer
Ø 18 mm
Graphite
Ceramic
NBR
FN-20
Ø 20 mm
Graphite
Ceramic
NBR
FN-24
Ø 24 mm
Graphite
Ceramic
NBR
FN-32 NU
Ø 32 mm
Graphite
Ceramic
NBR
6204 ZZ / 6204 ZZ 6206 ZZ - C3 / 6206 ZZ - C3 6306 ZZ - C3 / 6206 ZZ - C3 6308 ZZ - C3 / 6308 ZZ - C3
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
25 μF 450 VL
60 μF 250 VL
45 μF 450 VL
80 μF 250 VL
2CPm 25/14B 2CPm 25/16C 2CPm 25/14A 2CPm 25/16B 7
Rotational ring
Model
2CP 25/14 2CP 25/16 2CP 32/200 2CP 32/210 2CP 40/180 2CP 40/200 6
Materials Stationary ring
2CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2CP: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 11 kW ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IPX4.
5
6
1
2
84
4
3
7
5
DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w
s n1
MODEL
PORTS DN1
Single-phase
Three-phase
2CPm 25/14B 2CPm 25/14A 2CPm 25/16C 2CPm 25/16B – – – – – –
2CP 25/14B 2CP 25/14A 2CP 25/16C 2CP 25/16B 2CP 25/16A 2CP 32/200C-B 2CP 32/210B-A 2CP 40/180C 2CP 40/180B-A 2CP 40/200B-A
DN2
1¼”
1½” 2”
DIMENSIONS mm
1”
1¼” 1½”
a
82
95
f
h
h1
h2
n
n1
w
s
1~
3~
404
223 261 223
93 110 93
130 151 130
200 225 200
162 185 162
17 26 17
10 11 10
261
110
151
225
185
26
11
304
132
172
266
206
19
334
139
195
292
232
21
355
160
195
298
19.4 24.2 19.4 24.3 – – – – – –
18.8 23.0 18.8 23.2 24.5 38.0/43.0 54.0/61.0 49.0 54.0/60.0 89.0/90.0
464 542 496 542 566
108 110
kg
14
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
Single-phase 2CPm 25/14B 2CPm 25/14A 2CPm 25/16C 2CPm 25/16B
230 V 7.7 A 10.5 A 7.7 A 10.0 A
240 V 7.4 A 10.0 A 7.4 A 9.6 A
Three-phase 2CP 25/14B 2CP 25/14A 2CP 25/16C 2CP 25/16B 2CP 25/16A 2CP 32/200C 2CP 32/200B 2CP 32/210B 2CP 32/210A 2CP 40/180C 2CP 40/180B 2CP 40/180A 2CP 40/200B 2CP 40/200A
110 V 15.5 A 21.0 A 15.5 A 20.0 A
VOLTAGE (three-phase) 230 V 5.4 A 6.9 A 5.4 A 6.9 A 9.2 A 12.8 A 18.2 A 21.7 A 27.7 A 17.0 A 21.3 A 26.7 A – –
400 V 690 V 3.1 A 1.8 A 4.0 A 2.3 A 3.1 A 1.8 A 4.0 A 2.3 A 5.3 A 3.1 A 7.4 A 4.3 A 10.5 A 6.1 A 12.5 A 7.2 A 16.0 A 9.2 A 9.8 A 5.7 A 12.3 A 7.1 A 15.4 A 8.9 A 17.5 A 10.1 A 20.0 A 11.5 A
240 V 5.2 A 6.6 A 5.2 A 6.6 A 8.8 A 12.3 A 17.7 A 19.9 A 26.0 A 16.5 A 20.8 A 26.0 A – –
415 V 720 V 3.0 A 1.7 A 3.8 A 2.2 A 3.0 A 1.7 A 3.8 A 2.2 A 5.1 A 2.9 A 7.1 A 4.1 A 10.2 A 5.9 A 11.5 A 6.7 A 15.0 A 8.7 A 9.5 A 5.5 A 12.0 A 6.9 A 15.0 A 8.7 A 17.5 A 10.1 A 20.0 A 11.5 A
PALLETIZATION MODEL
H (mm) 1415 1590 1415 1590 1590 1420 1420 1420 1420 1420 1420 1420 1200 1200
1~ 994 1234 994 1239 – – – – – – – – – –
3~ 964 1174 964 1184 1249 700 790 670 750 610 670 740 551 557
n° H (mm) pumps 70 1925 70 2170 70 1925 70 2170 70 2170 24 1840 24 1840 16 1840 16 1840 16 1840 16 1840 16 1840 9 1730 9 1730
kg 1~ 1382 1718 1382 1725 – – – – – – – – – –
3~ 1340 1634 1340 1648 1739 930 1050 880 1000 800 880 980 818 827
H
0
Three-phase 2CP 25/14B 2CP 25/14A 2CP 25/16C 2CP 25/16B 2CP 25/16A 2CP 32/200C 2CP 32/200B 2CP 32/210B 2CP 32/210A 2CP 40/180C 2CP 40/180B 2CP 40/180A 2CP 40/200B 2CP 40/200A
CONTAINER kg
80
Single-phase 2CPm 25/14B 2CPm 25/14A 2CPm 25/16C 2CPm 25/16B – – – – – – – – – –
GROUPAGE n° pumps 50 50 50 50 50 18 18 12 12 12 12 12 6 6
00
12
85
2÷4CP Multi-stage centrifugal pumps
PERFORMANCE RANGE
•• Flow rate up to 130 l/min (7.8 m³/h) •• Head up to 52 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
86
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their quietness, these pumps are widely used in domestic applications such as the distribution of water in combination with small and medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 002073635
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
4CP80-C 4CP100-C
Head H (metres) 4
3CP80-C 3CP100-C
2CP80-C
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase
kW
HP
2CPm 80-C
–
0.37
0.50
3CPm 80-C
3CP 80-C
0.45
0.60
4CPm 80-C
4CP 80-C
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.4
3.0
3.6
4.2
4.8
5.4
l/min
0
5
10
15
20
25
30
40
50
60
70
80
90 100 110 120 130
27
26
25
24 22.5 21
20 16.5
13
9
5
40
38
37
36 34.5 33
31
27 22.5 17
11
40
0.60
0.85
H metres 52
50
49
47 44.5 42
34 28.5 22.5 16
10
0.60
0.85
38
37
36
35 34.5 33.5 33
31
20
4CPm 100-C 4CP 100-C
0.75
1
50
50
49
48
42 39.5 37
Q = Flow rate H = Total manometric head HS = Suction height
47
46
45
26
23
6.6
7.2
7.8
5
3CPm 100-C 3CP 100-C
28
6.0
17
13.5
34 30.5 26.5 22
10
5
17
11
5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
87
2÷4CP POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
IMPELLERS
Noryl
4
DIFFUSERS
Noryl complete with anti-wear ring
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
STA-13
Ø 13 mm
Pump
Model
7
BEARINGS
2CP 80-C 3CP 80-C 4CP 80-C 3CP 100-C 4CP 100-C 8
9
CAPACITOR
Rotational ring
Elastomer
Ceramic
Graphite
NBR
6202 ZZ - C3 / 6201 ZZ 6203 ZZ / 6203 ZZ
Pump
ELECTRIC MOTOR
Materials Stationary ring
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
2CPm 80-C 3CPm 80-C 4CPm 80-C 3CPm 100-C 4CPm 100-C
10 μF 450 VL 12.5 μF 450 VL
25 μF 250 VL 25 μF 250 VL
14 μF 450 VL
25 μF 250 VL
20 μF 450 VL
60 μF 300 VL
2-3-4CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2-3-4CP: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4. 7
1
88
4
3
5
2
8
6
9
7
DIMENSIONS AND WEIGHT f
n
a
h1
h
h3
DN1
h2
DN2
s
w n1
MODEL
PORTS
Single-phase
Three-phase
2CPm 80-C
–
3CPm 80-C
3CP 80-C
4CPm 80-C
4CP 80-C
DN1
1”
DIMENSIONS mm
DN2
1”
a
f
85
303
110
328
3CPm 100-C
3CP 100-C
85
303
4CPm 100-C
4CP 100-C
110
356
h
172
h1
h2
134
h3
38
172
kg n
158
n1
w
116
1.5
s
9
191
1~
3~
9.0
–
9.8
9.3
11.0
10.4
10.4
9.9
13.7
12.7
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
2CPm 80-C
2.4 A
2.4 A
4.8 A
3CP 80-C
2.5 A
1.4 A
0.8 A
2.4 A
1.4 A
0.8 A
3CPm 80-C
3.4 A
3.3 A
6.8 A
4CPm 80-C
4.3 A
4.2 A
8.6 A
4CP 80-C
3.4 A
2.0 A
1.1 A
3.3 A
1.9 A
1.1 A
3CPm 100-C
4.1 A
4.0 A
8.2 A
3CP 100-C
3.1 A
1.8 A
1.0 A
3.0 A
1.7 A
1.0 A
4CPm 100-C
6.0 A
5.8 A
12.0 A
4CP 100-C
4.5 A
2.6 A
1.5 A
4.3 A
2.5 A
1.4 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
kg
3~
n° pumps
H (mm)
1~
3~
867
–
140
2150
1228
–
Single-phase
Three-phase
2CPm 80-C
–
98
1547
3CPm 80-C
3CP 80-C
98
1547
945
896
140
2150
1340
1270
4CPm 80-C
4CP 80-C
98
1547
1082 1053
140
2150
1536
1494
3CP 100-C
98
1547
994
965
140
2150
1410
1368
4CP 100-C
84
1661
1150
1150
108
2102
1471
1471
0
80
3CPm 100-C 4CPm 100-C
H
00
12
89
2÷4CR Multi-stage centrifugal pumps
PERFORMANCE RANGE
•• Flow rate up to 120 l/min (7.2 m³/h) •• Head up to 50 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their quietness, these pumps are widely used in domestic applications such as the distribution of water in combination with small and medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
OPTIONALS AVAILABLE ON REQUEST
CONSTRUCTION AND SAFETY STANDARDS
•• Special mechanical seal •• Other voltages or 60 Hz frequency
EN 60335-1 IEC 60335-1 CEI 61-150
GUARANTEE
EN 60034-1 IEC 60034-1 CEI 2-3
1 year subject to terms and conditions
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
90
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
Head H (metres) 4
4CR80
3CR80 3CR100
2CR80
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
l/min
0
5
10
15
20
25
30
40
50
60
70
80
90
100 110 120
20
19
17.5
15
11.5
8
5
32.5
31
29
25
20
15.5
10
28
22.5
16
10
28
25.5
23
20
17
13.5
2CRm 80
–
0.37
0.50
25
24
3CRm 80
3CR 80
0.45
0.60
38
36
4CRm 80
4CR 80
0.60
0.85
3CRm 100
3CR 100
0.60
0.85
H metres
Q = Flow rate H = Total manometric head HS = Suction height
22.5 21.5 35
34
50
48
47
45
36
35.5
35
34
43
40.5 38.5 33.5
33.5 32.5
32
30
6.6
7.2
5 10
5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
91
2÷4CR POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
IMPELLERS
Noryl GFN2V
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
STA-13
Ø 13 mm
6
BEARINGS
6202 ZZ- C3 / 6201 ZZ
7
CAPACITOR
Pump
8
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
2CRm 80 3CRm 80 4CRm 80 3CRm 100
10 μF 450 VL 12.5 μF 450 VL
25 μF 250 VL 25 μF 250 VL
14 μF 450 VL
25 μF 250 VL
2÷4CRm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2÷4CR: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
92
3
2
7
5
4
8
6
DIMENSIONS AND WEIGHT
f
n
a
h1
h
DN1
h2
DN2
w
MODEL
PORTS
Single-phase
Three-phase
2CRm 80
–
3CRm 80 4CRm 80 3CRm 100
3CR 80 4CR 80 3CR 100
DN1
1”
s
n1
DIMENSIONS mm
DN2
1”
a
f
90
339
h
h1
174
h2
122
52
n
160
kg n1
w
120
s
88
9
1~
3~
5.9
–
6.8 7.3 7.2
6.2 6.8 6.7
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
2CRm 80
2.4 A
2.4 A
4.8 A
3CR 80
2.2 A
1.3 A
0.8 A
2.1 A
1.2 A
0.7 A
3CRm 80
3.2 A
2.9 A
6.5 A
4CRm 80
4.0 A
3.6 A
8.0 A
4CR 80
2.9 A
1.7 A
1.0 A
2.8 A
1.6 A
0.9 A
3CRm 100
4 .0A
3.6 A
8.0 A
3CR 100
2.9 A
1.7 A
1.0 A
2.8 A
1.6 A
0.9 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
1~
–
98
1440
600
–
154
2180
930
–
3CRm 80
3CR 80
98
1440
690
630
154
2180
1070
970
4CRm 80
4CR 80
98
1440
730
680
154
2180
1140
1070
3CRm 100
3CR 100
98
1440
720
680
154
2180
1130
1050
Single-phase
Three-phase
2CRm 80
3~ H
0
80
00
12
93
MK Vertical multi-stage pumps
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The high efficiency and adaptability of these pumps to even the most unusual of applications, makes them ideal for use in the domestic, civil and industrial sectors; in particular for the distribution of water in combination with pressure sets and for pressure boosting. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 180 l/min (10.8 m³/h) •• Head up to 103 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 10 bar •• Continuous service S1
OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
REGULATION (EU) N. 547/2012
•• Suction and delivery ports with threaded flanges in compiance with ISO 228/1 (1” - 1¼” - 1½)
•• Other voltages or 60 Hz frequency GUARANTEE 1 year subject to terms and conditions
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
94
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
110
10
0
100
30 20
η = 48%
MK5/8
US g.p.m.
40 30
η = 55%
40
Imp g.p.m.
feet 350
η = 65%
300
90
MK3/7
MK5/7
80 Head H (metres) 4
20 10
MK3/8
50 Hz n= 2900 1/min HS= 0 m
MK8/6
MK5/6
250
MK3/6
70
MK8/5 MK5/5
60
MK3/5
50
MK3/4
200 MK8/4 MK5/4 150
40 100
30 20
50
10
0
20
0
1
40 2
60 3
80 4
100 5
120
6
7
140 8
160 9
180 10
l/min m³/h
11
Flow rate Q 4
MODEL Single-phase MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6
Three-phase MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6
POWER kW 0.75 0.75 1.1 1.1 1.5 1.1 1.5 1.8 2.2 2.2 1.5 1.8 2.2
HP 1 1 1.5 1.5 2 1.5 2 2.5 3 3 2 2.5 3
Q = Flow rate H = Total manometric head HS = Suction height
Q
m³/h
0
0.6
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
l/min
0
10
20
40
60
80
100
120
140
160
180
25
22
31.5
24.0
15.0
H metres
50
49
47
42.5
35
62
60
58.5
52.5
43.5
30
75
73
70
62.5
51.5
36
88
85
81.5
73
59.5
42
100
98
94
85
70.5
50
53
–
51
48
45
40
32
67
–
64
61
57.5
51
41.5
29
80
–
77
74
70
61
49
34
87
–
84
80
75
64.5
51.5
37
103
–
99
93
85
74.5
58.5
40
56.0
–
–
54.0
52.0
50.0
46.0
39.0
70.0
–
–
67.5
66.0
63.0
58.0
50.0
40.0
30.0
18.0
86.0
–
–
82.0
78.0
74.0
68.0
58.0
46.5
35.0
20.0
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
95
MK POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
SUCTION BODY
Cast iron, complete with threaded suction port in compliance with ISO 228/1
2
EXTERNAL SLEEVE
Stainless steel AISI 304
3
DELIVERY BODY
Cast iron, complete with threaded suction port in compliance with ISO 228/1
4
IMPELLERS AND DIFFUSERS
Noryl GFN2V
5
DIAPHRAGMS
Stainless steel AISI 304 complete with anti-wear rings
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
MECHANICAL SEAL
Shaft
Position
Diameter
FN-18 8
Ø 18 mm
Materials Stationary ring
Rotational ring
Elastomer
Graphite
Ceramic
NBR
BEARINGS Model 6304 ZZ / 6204 ZZ
9
CAPACITOR Pump
10
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6
25 μF 450 VL 25 μF 450 VL 25 μF 450 VL 25 μF 450 VL 31.5 μF 450 VL 25 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL 50 μF 450 VL 50 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL 50 μF 450 VL
60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL – – – 60 μF 250 VL – –
ELECTRIC MOTOR
8
9
10
6 8
7
➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance MKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. MK: three-phase 230/400 V - 50 Hz. – Insulation: F class. – Protection: IP X4.
96
3
2 5 4
1
DIMENSIONS AND WEIGHT
ABSORPTION MODEL
h2
h
DN2
a
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6
5.0 A 6.0 A 6.5 A 7.0 A 9.0 A 6.5 A 8.5 A 9.5 A 10.5 A 11.5 A 8.5 A 9.5 A 11.5 A
4.8 A 5.8 A 6.3 A 6.8 A 8.7 A 6.3 A 8.2 A 9.1 A 10.2 A 11.0 A 8.2 A 9.1 A 11.0 A
10.0 A 12.0 A 13.0 A 14.0 A 18.0 A 13.0 A 17.0 A 19.0 A 21.0 A 23.0 A 17.0 A 19.0 A 23.0 A
h1
DN1
MODEL
s
w2
b
n3
n2
c
w1 n1
MODEL Single-phase MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6
Three-phase MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6
PORTS DN1
1¼”
DN2
1”
N° STAGES 4 5 6 7 8 4 5 6 7 8 4 5 6
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6
3.5 A 4.2 A 4.8 A 5.2 A 5.5 A 4.8 A 5.2 A 6.1 A 7.8 A 8.7 A 5.2 A 6.1 A 8.7 A
2.0 A 2.4 A 2.8 A 3.0 A 3.2 A 2.8 A 3.0 A 3.5 A 4.5 A 5.0 A 3.0 A 3.5 A 5.0 A
1.2 A 1.4 A 1.6 A 1.7 A 1.8 A 1.6 A 1.7 A 2.0 A 2.6 A 2.9 A 1.7 A 2.0 A 2.9 A
3.4 A 4.0 A 4.6 A 5.0 A 5.3 A 4.6 A 5.0 A 5.8 A 7.5 A 8.3 A 5.0 A 5.8 A 8.3 A
2.0 A 2.3 A 2.7 A 2.9 A 3.1 A 2.7 A 2.9 A 3.4 A 4.3 A 4.8 A 2.9 A 3.4 A 4.8 A
1.2 A 1.3 A 1.6 A 1.7 A 1.8 A 1.6 A 1.7 A 2.0 A 2.5 A 2.8 A 1.7 A 2.0 A 2.8 A
DIMENSIONS mm a
s
91
94.5
h 469 493 517 541 565 469 493 517 541 565 469 493 517
h1
41.5
h2 152 176 200 224 248 152 176 200 224 248 152 176 200
kg
w1
w2
n1
n2
n3
b
c
143
146
194
130
225
9.5
14.5
1~ 22.3 23.1 23.9 24.7 26.6 22.3 24.3 25.8 27.3 28.0 23.6 25.1 26.6
3~ 21.6 22.4 23.2 24.0 25.6 21.6 23.4 25.0 26.6 27.3 22.7 24.3 25.9
PALLETIZATION MODEL Three-phase MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6
n° pumps 35 35 35 35 35 35 35 35 35 35 35 35 35
H (mm) 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440
kg 1~ 798 826 854 882 948 798 868 920 973 997 843 896 948
3~ 773 801 829 857 913 773 836 892 948 973 812 868 924
H
0 80
Single-phase MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6
GROUPAGE / CONTAINER
00
12
97
CK Self-priming liquid ring pumps
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with diesel, clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a specific result of the pump’s operating principle they are suitable for use in all situations where a compact self-priming pump is required or where the fluid supply is limited, irregular or contains air. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 51 m
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +90 °C •• Temperature of diesel up to +55°C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
PATENTS - TRADE MARKS - MODELS
CONSTRUCTION AND SAFETY STANDARDS
•• Motor bracket: patent n° IT1243605 •• CK 80-E/90-E Registered Community Design n° 342159-0008
EN 60335-1 IEC 60335-1 CEI 61-150
OPTIONALS AVAILABLE ON REQUEST
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
98
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for CK 80-E, CK 90-E
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
CK90-E
Head H (metres) 4
CK80-E
CK50
CK50-BP
Flow rate Q 4 MODEL
POWER kW
HP
CK 50
0.37
0.50
CKm 50-BP
CK 50-BP
0.25
0.33
CKm 80-E
CK 80-E
0.55
0.75
CKm 90-E
CK 90-E
0.75
1
Single-phase Three-phase CKm 50
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
0
5
10
15
20
25
30
35
40
50
35
31
27
24
20
16
13
9
5
20
20
20
20
20
16.5
13
9
5
48
46
42
38
34
30
26
22
18
10
51
49
45
41
37
33
29
25
21
13
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
CK 50-BP = pump with integral by-pass
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
99
CK POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
MOTOR BRACKET
Aluminium with brass insert (patented), reduces the risk of impeller seizure
3
IMPELLER
Brass, star type with open radial vanes
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-12V
Ø 12 mm
Pump
Model
6
BEARINGS
CK 50 CK 50-BP CK 80-E CK 90-E 7
CAPACITOR
ELECTRIC MOTOR
Rotational ring
Elastomer
Ceramic
Graphite
Viton
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
12.5 μF 450 VL
25 μF 250 VL
16 μF 450 VL 20 μF 450 VL
60 μF 300 VL 60 μF 300 VL
CKm 50 CKm 50-BP CKm 80-E CKm 90-E 8
Materials Stationary ring
CKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CK: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
100
3
2
7
5
4
6
8
DIMENSIONS AND WEIGHT
i
f
h1
h3
h
h2
DN1
DN2
n1
s a
w
MODEL
m
n
PORTS
Single-phase
Three-phase
CKm 50
CK 50
CKm 50-BP
CK 50-BP
CKm 80-E
CK 80-E
CKm 90-E
CK 90-E
DIMENSIONS mm
DN1
DN2
¾”
¾”
1”
1”
a
f
41
250
45
254
50
296
kg
h
h1
h2
h3
i
m
n
n1
w
152
128
23
151
75
80
120
100
69
s
7 180
136
31
167
81
90
140
112
77
1~
3~
7.4
6.8
10.8
9.9
10.9
10.0
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
CKm 50
3.0 A
2.9 A
6.2 A
CK 50
2.1 A
1.2 A
0.7 A
2.0 A
1.2 A
0.7 A
CKm 50-BP
3.0 A
2.9 A
6.2 A
CK 50-BP
2.1 A
1.2 A
0.7 A
2.0 A
1.2 A
0.7 A
CKm 80-E
5.0 A
4.8 A
9.8 A
CK 80-E
3.5 A
2.0 A
1.2 A
3.4 A
2.0 A
1.2 A
CKm 90-E
4.8 A
4.4 A
9.4 A
CK 90-E
3.5 A
2.0 A
1.2 A
3.4 A
2.0 A
1.2 A
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
PALLETIZATION MODEL Single-phase
Three-phase
CKm 50
CK 50
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
120
1280
910
kg
3~
n° pumps
H (mm)
1~
3~
840
180
1850
1350
1240
CKm 50-BP
CK 50-BP
120
1280
910
840
180
1850
1350
1240
CKm 80-E
CK 80-E
102
1370
1120
1030
136
1780
1490
1370
CKm 90-E
CK 90-E
102
1370
1130
1040
136
1780
1500 1380
H
0
80
00
12
101
CKR Self-priming liquid ring pumps ➠ with double anti-seize inserts
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use with clean water or liquids that do not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a specific result of the pump’s operating principle they are suitable for use in all situations where a compact self-priming pump is required or where the fluid supply is limited, irregular or contains air. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 51 m •• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +90 °C •• Temperature of diesel up to +55°C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
PATENTS - TRADE MARKS - MODELS
CONSTRUCTION AND SAFETY STANDARDS
•• Motor bracket: patent n° IT1243605 •• Registered Community Design n° 342159-0008
EN 60335-1 IEC 60335-1 CEI 61-150
OPTIONALS AVAILABLE ON REQUEST
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
102
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IPX5 class protection
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
CKR90-E
Head H (metres) 4
CKR80-E
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase
kW
HP
CKRm 80-E
CKR 80-E
0.55
0.75
CKRm 90-E
CKR 90-E
0.75
1
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
48
46
42
38
34
30
26
22
18
10
51
49
45
41
37
33
29
25
21
13
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
103
CKR POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with stainless steel insert to prevent impeller seizure due to the formation of rust . The pump body is complete with threaded ports in compliance with ISO 228/1
2
MOTOR BRACKET
Aluminium with brass insert (patented), reduces the risk of impeller seizure
3
IMPELLER
Brass, star type with open radial vanes
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-12V
Ø 12 mm
6
BEARINGS
6203 ZZ / 6203 ZZ
7
CAPACITOR
Pump
8
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
Viton
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
CKRm 80-E CKRm 90-E
16 μF 450 VL 20 μF 450 VL
60 μF 300 VL 60 μF 300 VL
CKRm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CKR: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
6
1
104
3
2
6
7
5
4
8
DIMENSIONS AND WEIGHT
i
f
h1
h3
h
h2
DN1
DN2
n1
s a
w
MODEL
m
n
PORTS
Single-phase
Three-phase
CKRm 80-E
CKR 80-E
CKRm 90-E
CKR 90-E
DN1 1”
DIMENSIONS mm
DN2 1”
a 50
f
h
296
180
h1
h2
136
h3
31
i
167
81
kg m
n
90
140
n1 112
w 77
s 7
1~
3~
10.8
9.9
10.9
10.0
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
MODEL
VOLTAGE (three-phase)
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
CKRm 80-E
5.0 A
4.8 A
9.8 A
CKR 80-E
3.5 A
2.0 A
1.2 A
3.4 A
2.0 A
1.2 A
CKRm 90-E
4.8 A
4.4 A
9.4 A
CKR 90-E
3.5 A
2.0 A
1.2 A
3.4 A
2.0 A
1.2 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
CKR 80-E
102
1370
CKR 90-E
102
1370
Single-phase
Three-phase
CKRm 80-E CKRm 90-E
CONTAINER kg 3~
n° pumps
H (mm)
1120
1030
136
1130
1040
136
1~
kg 1~
3~
1780
1490
1370
1780
1500 1380
H
0 80
00
12
105
JSW1 Self-priming “JET” pumps
PERFORMANCE RANGE
•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 47 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• Registered Italian model nº 72753 •• European Patent n° 1 510 696
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with technopolymer impeller •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
106
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
JSW1A
JSW1B
Head H (metres) 4
JSW1C
4
4 4
Flow rate Q 4
MODEL Single-phase Three-phase JSWm 1C – JSWm 1B JSW 1B JSWm 1A JSW 1A
POWER kW 0.37 0.50 0.60
HP 0.50 0.70 0.85
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
5
10
15
20
25
30
35
40
45
50
35
32
27
24
21
19
17
16
15
14
13
41
36
31
27
24
22
20
19
17
16
15
47
42
38
34
31
28.5
26
24
22
21.5
19
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
107
JSW1 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
NOZZLE ASSEMBLY
Noryl GFN2V
4
IMPELLER
Brass
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-12
Ø 12 mm
7
BEARINGS
6201 ZZ / 6201 ZZ
8
CAPACITOR
Pump
9
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
JSWm 1C JSWm 1B JSWm 1A
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL
25 μF 250 VL 25 μF 250 VL 25 μF 250 VL
JSWm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JSW: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
1
108
3
4
7
6
8
5
9
7
DIMENSIONS AND WEIGHT f
n
a
h1
h
h3
DN1
h2
DN2
w
MODEL
PORTS
Single-phase
Three-phase
JSWm 1C
–
JSWm 1B
JSW 1B
JSWm 1A
JSW 1A
DN1 1”
s
n1
DIMENSIONS mm
DN2 1”
a
f
115
373
h 171
h1 127
h2 33.5
h3 160.5
kg n 160
n1
w
124
24
s 10
1~
3~
9.2
–
10.0
9.5
10.3
10.1
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
MODEL
VOLTAGE (three-phase)
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
JSW 1B
2.1 A
1.2 A
0.7 A
2.0 A
1.2 A
0.7 A
JSW 1A
2.8 A
1.6 A
0.9 A
2.7 A
1.6 A
0.9 A
JSWm 1C
2.4 A
2.2 A
4.8 A
JSWm 1B
3.2 A
2.9 A
6.5 A
JSWm 1A
3.6 A
3.3 A
7.3 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~ 926
kg
3~
n° pumps
H (mm)
1~
–
140
2060
1312
Single-phase
Three-phase
JSWm 1C
–
98
1484
3~
JSWm 1B
JSW 1B
98
1484 1004
955
140
2060 1424
JSWm 1A
JSW 1A
98
1484 1033
1014
140
2060 1466 1438
–
H
1354
0 80
00
12
109
JSW2 Self-priming “JET” pumps
PERFORMANCE RANGE
•• Flow rate up to 80 l/min (4.8 m³/h) •• Head up to 70 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6.5 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• Registered Italian model nº 72753 •• European Patent n° 1 510 696
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with technopolymer impeller •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
110
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
JSW15H
JSW12H
Head H (metres) 4
JSW10H JSW15M JSW12M
JSW10M
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase JSWm 10H JSW 10H JSWm 12H JSW 12H JSWm 15H JSW 15H JSWm 10M JSW 10M JSWm 12M JSW 12M JSWm 15M JSW 15M
kW 0.75 0.90 1.1 0.75 0.90 1.1
HP 1 1.25 1.5 1 1.25 1.5
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.4
2.7
3.0
3.6
4.2
4.8
l/min
0
5
10
15
20
25
30
40
45
50
60
70
80
56
51
47
44
41
39
36
32
30
28
64
58
54
51
48
45
43
38
36
34
70
66
62
58
54
51
48
43
41
38
46
42
40
38
37
35
33
30
29
27
25
23
21
50
48
46
44
42
41
39
36
35
33
31
29
27
55
52
50
48
46
45
43
40
39
37
35
33
30
H metres
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
111
JSW2 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
NOZZLE ASSEMBLY
Noryl GFN2V
4
IMPELLER
Brass
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
AR-14
Ø 14 mm
7
BEARINGS
6203 ZZ / 6203 ZZ
8
CAPACITOR
Pump
9
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
JSWm 10H-M JSWm 12H-M JSWm 15H-M
20 μF 450 VL 25 μF 450 VL 25 μF 450 VL
60 μF 300 VL 60 μF 300 VL 60 μF 300 VL
JSWm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JSW: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
1
112
3
7
4
6
8
5
9
7
DIMENSIONS AND WEIGHT
f
n
a
h1
h
h3
DN1
h2
DN2
w
MODEL
PORTS DN1
s
n1
DIMENSIONS mm
Single-phase
Three-phase
1~
3~
JSWm 10H
JSW 10H
13.7
13.8
JSWm 12H
JSW 12H
14.7
13.6
JSWm 15H
JSW 15H
15.1
14.8
JSWm 10M
JSW 10M
13.7
13.8
JSWm 12M
JSW 12M
14.7
13.6
JSWm 15M
JSW 15M
15.1
14.8
1”
DN2
1”
a
f
113.5
h
402
201
h1
h2
147
h3
kg
35
182
n
180
n1
w
142
22
s
10
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
JSWm 10H
4.7 A
4.5 A
9.4 A
JSW 10H
3.5 A
2.0 A
1.2 A
3.4 A
2.0 A
1.2 A
JSWm 12H
5.4 A
5.0 A
10.8 A
JSW 12H
4.2 A
2.4 A
1.4 A
4.0 A
2.3 A
1.3 A
JSWm 15H
6.6 A
6.0 A
13.2 A
JSW 15H
5.5 A
3.2 A
1.8 A
5.3 A
3.1 A
1.8 A
JSWm 10M
5.0 A
4.6 A
10.0 A
JSW 10M
3.6 A
2.1 A
1.2 A
3.5 A
2.0 A
1.2 A
JSWm 12M
5.7 A
5.2 A
11.4 A
JSW 12M
4.5 A
2.6 A
1.5 A
4.3 A
2.5 A
1.4 A
JSWm 15M
6.6 A
6.0 A
13.2 A
JSW 15M
5.5 A
3.2 A
1.8 A
5.3 A
3.1 A
1.8 A
PALLETIZATION MODEL
GROUPAGE n° pumps
Single-phase
Three-phase
JSWm 10H
JSW 10H
72
H (mm)
CONTAINER kg
1~
1460 1000
H (mm)
kg
3~
n° pumps
1010
96
1900 1330
1~
3~ 1340
JSWm 12H
JSW 12H
72
1460 1080 1000
96
1900 1430
1330
JSWm 15H
JSW 15H
72
1460
96
1900
1470
1440
1110
1090
JSW 10M
72
1460 1000
1010
96
1900 1330
1340
JSW 12M
72
1460 1080 1000
96
1900 1430
1330
JSWm 15M
JSW 15M
72
1460
96
1900
1440
1110
1090
1470
0 80
JSWm 10M JSWm 12M
H
00
12
113
JSW3 Self-priming “JET” pumps
PERFORMANCE RANGE
•• Flow rate up to 160 l/min (9.6 m³/h) •• Head up to 96 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 10 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic, civil and industrial applications such as the distribution of water in combination with pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• Registered Italian model nº 72753
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IPX5 class protection
GUARANTEE 1 year subject to terms and conditions
114
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
JSW3AH
Head H (metres) 4
JSW3BH
JSW3CH
JSW3AM
JSW3AL
JSW3BM
JSW3CM
JSW3BL JSW3CL
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase JSWm 3CH JSW 3CH JSWm 3BH JSW 3BH – JSW 3AH JSWm 3CM JSW 3CM JSWm 3BM JSW 3BM – JSW 3AM JSWm 3CL JSW 3CL JSWm 3BL JSW 3BL – JSW 3AL
kW 1.1 1.5 2.2 1.1 1.5 2.2 1.1 1.5 2.2
HP 1.5 2 3 1.5 2 3 1.5 2 3
m³/h
0
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
3.6
4.2
4.8
l/min
0
10
15
20
25
30
35
40
45
50
60
70
80 100 120 140 160
64 76 96 52 H metres 60 74 42 51 62
60 70 90 50 58 70 40 48 60
55 67 86 48 56 68 39 46 58
51 64 82 45 54 67 38 45 57
48 61 79 44 52 65 37 44 56
45 42.5 40 58 55.5 53 75 71.5 69 42 40 38 51 49 47 63 61 59 36 35 34 43 42 41 55 54 53
39 51 66 37 46 58 33 40 52
37 49 64 35 45 56 32 39 51
34 45 58 32 42 54 30 37 49
31 41 54 29 39 51 28 35 47
39 50 27 37 49 26 33 45
Q
Q = Flow rate H = Total manometric head HS = Suction height
6.0
23 33 44 23 30 42
7.2
8.4
9.6
20 30 40 20 17 15 27 24 22 39 36.5 35
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
115
JSW3 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Cast iron
3
NOZZLE ASSEMBLY
Noryl GFN2V
4
IMPELLER
Brass
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
FN-18
Ø 18 mm
7
BEARINGS
6204 ZZ / 6204 ZZ
8
CAPACITOR
Pump
9
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Graphite
Ceramic
NBR
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
JSWm 3C JSWm 3B
31.5 μF 450 VL 45 μF 450 VL
60 μF 250 VL 80 μF 250 VL
JSWm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JSW: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
7
2
1
116
3
4
6
8
5
9
7
DIMENSIONS AND WEIGHT f
n
a
h
h2 h1
h3
DN1
DN2
w
MODEL
PORTS
Single-phase
Three-phase
JSWm 3CH JSWm 3BH – JSWm 3CM JSWm 3BM – JSWm 3CL JSWm 3BL –
JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL
DN1
1¼”
s
n1
DIMENSIONS mm
DN2
1”
a
f
155
h
530
242
h1
h2
165
43
h3
208
kg n
206
n1
w
164
30
s
1~
3~
11
24.9 26.1 – 24.9 26.1 – 24.9 26.1 –
22.9 25.1 26.4 22.9 25.1 26.4 22.9 25.1 26.4
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
JSWm 3CH JSWm 3BH JSWm 3CM JSWm 3BM JSWm 3CL JSWm 3BL
8.0 A 9.0 A 7.9 A 9.3 A 7.5 A 9.7 A
7.3 A 8.2 A 7.2 A 8.5 A 6.9 A 9.0 A
16.0 A 18.0 A 15.8 A 18.6 A 15.0 A 19.4 A
JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL
5.5 A 6.9 A 9.0 A 5.9 A 7.3 A 9.5 A 5.5 A 7.3 A 9.0 A
3.2 A 4.0 A 5.2 A 3.4 A 4.2 A 5.5 A 3.2 A 4.2 A 5.2 A
1.8 A 2.3 A 3.0 A 2.0 A 2.4 A 3.2 A 1.8 A 2.4 A 3.0 A
5.3 A 6.6 A 8.6 A 5.7 A 7.0 A 9.1 A 5.3 A 7.0 A 8.6 A
3.1 A 3.8 A 5.0 A 3.3 A 4.0 A 5.3 A 3.1 A 4.0 A 5.0 A
1.8 A 2.2 A 2.9 A 1.9 A 2.3 A 3.1 A 1.8 A 2.3 A 2.9 A
PALLETIZATION MODEL Three-phase JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL
H (mm)
35 35 35 35 35 35 35 35 35
1420 1420 1420 1420 1420 1420 1420 1420 1420
CONTAINER kg
1~ 890 930 – 890 930 – 890 930 –
3~ 820 900 941 820 900 941 820 900 941
n° pumps
H (mm)
49 49 49 49 49 49 49 49 49
1930 1930 1930 1930 1930 1930 1930 1930 1930
kg 1~ 3~ 1240 1140 1300 1250 – 1310 1240 1140 1300 1250 – 1310 1240 1140 1300 1250 – 1310
H
0 80
Single-phase JSWm 3CH JSWm 3BH – JSWm 3CM JSWm 3BM – JSWm 3CL JSWm 3BL –
GROUPAGE n° pumps
00
12
117
JCR Self-priming “JET” pumps
PERFORMANCE RANGE
•• Flow rate up to 80 l/min (4.8 m³/h) •• Head up to 72 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6.5 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
118
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JCR pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• European Patent n° 1 510 696
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
JCR15H
Head H (metres) 4
JCR10H JCR15M JCR1A
JCR1B
JCR10M
JCR1C
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase JCRm 1C – JCRm 1B JCR 1B JCRm 1A JCR 1A JCRm 10H JCR 10H JCRm 15H JCR 15H JCRm 10M JCR 10M JCRm 15M JCR 15M
kW 0.37 0.50 0.60 0.75 1.1 0.75 1.1
HP 0.50 0.70 0.85 1 1.5 1 1.5
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
60
70
80
0
5
10
15
20
25
30
35
40
50
35
32
27
24
21
19
17
16
15
13
41
36
31
27
24
22
20
19
17
15
47
42
38
34
31
28.5
26
24
22
19
56
50
45
41
37
33
30
27
25
22
72
67
61
56
51
47
43
40
37
32
46
44
41
39
37
35
32
30
28
25
22
21
19
55
53
50
48
46
43
41
39
37
34
31
29
27
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
119
JCR POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
NOZZLE ASSEMBLY
Noryl GFN2V
4
IMPELLER
Noryl GFN2V
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
JCR 1C-B-A JCR 10-15
AR-12 AR-14
Ø 12 mm Ø 14 mm
Pump
Model
JCR 1C-B-A JCR 10H-M / 15H-M
6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ
Pump
Capacitance
7
8
9
BEARINGS
CAPACITOR
ELECTRIC MOTOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Ceramic
Graphite Graphite
NBR NBR
Single-phase
(230 V or 240 V)
(110 V)
JCRm 1C JCRm 1B JCRm 1A JCRm 10H-M JCRm 15H-M
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL 20 μF 450 VL 25 μF 450 VL
25 μF 250 VL 25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL
JCRm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JCR: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
1
120
3
7
4
6
8
5
7
9
DIMENSIONS AND WEIGHT
f
n
a
h1
h
h2
DN1
DN2
w
MODEL
PORTS
Single-phase
Three-phase
JCRm 1C
–
JCRm 1B
JCR 1B
JCRm 1A JCRm 10H-M JCRm 15H-M
JCR 15H-M
DN1
s
n1
DIMENSIONS mm
DN2
1~
3~
5.6
–
6.4
6.3
JCR 1A
6.9
6.4
JCR 10H-M
9.4
9.3
10.5
10.3
1”
1¼”
1”
1”
a
f
90
h
339
117
h1
174
406
206
h2
122
52
145
55
n
kg
160
184
n1
w
120
s
88
135
9
110
10
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
Single-phase
230 V
240 V
110 V
JCRm 1C
2.4 A
2.2 A
4.8 A
JCRm 1B
3.2 A
2.9 A
6.5 A
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
JCR 1B
2.1 A
JCR 1A
2.8 A
JCR 10H
720 V
1.2 A
0.7 A
2.0 A
1.2 A
0.7 A
1.6 A
0.9 A
2.7 A
1.6 A
0.9 A
3.5 A
2.0 A
1.2 A
3.4 A
2.0 A
1.2 A
JCR 15H
5.5 A
3.2 A
1.8 A
5.3 A
3.1 A
1.8 A
JCRm 1A
3.6 A
3.3 A
7.3 A
JCRm 10H
4.7 A
4.5 A
9.4 A
JCRm 15H
6.6 A
6.0 A
13.2 A
JCRm 10M
5.0 A
4.6 A
10.0 A
JCR 10M
3.6 A
2.1 A
1.2 A
3.5 A
2.0 A
1.2 A
JCRm 15M
6.6 A
6.0 A
13.2 A
JCR 15M
5.5 A
3.2 A
1.8 A
5.3 A
3.1 A
1.8 A
PALLETIZATION MODEL
GROUPAGE H (mm)
–
98
1440
JCR 1B
98
1440
JCRm 1A
JCR 1A
98
1440
JCRm 10H-M
JCR 10H-M
72
1460
JCRm 15H-M
JCR 15H-M
72
1460
Three-phase
JCRm 1C JCRm 1B
kg
kg
3~
n° pumps
H (mm)
570
–
154
2180
880
–
650
640
154
2180
1010
990
700
650
154
2180 1080
1010
700
690
96
1900
920
910
780
760
96
1900 1030
1010
1~
1~
3~ H
0 80
n° pumps
Single-phase
CONTAINER
00
12
121
PLURIJET 80-100 Self-priming multi-stage pumps
PERFORMANCE RANGE
•• Flow rate up to 130 l/min (7.8 m³/h) •• Head up to 50 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Suitable for use with clean water even where air is present and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming “PLURIJET” pumps are designed to pump water even in cases where air is present. As a result of their quietness, reliability and low energy consumption they are recommended for use in domestic and civil applications such as the pressurisation and distribution of water in combination with pressure sets, and in rain water recovery and irrigation systems, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• PLURIJET® is a registered trade mark n° 3974301 •• Registered Community Design n° 342159-0006
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
122
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
PLURIJET 4/80
Head H (metres) 4
4/100 3/80 3/100
Flow rate Q 4 MODEL Single-phase
POWER Three-phase
kW
HP 0.60
PLURIJETm 3/80
–
0.45
PLURIJETm 4/80
PLURIJET 4/80
0.60
0.85
PLURIJETm 3/100
PLURIJET 3/100
0.60
0.85
PLURIJETm 4/100
PLURIJET 4/100
0.75
1
Q = Flow rate H = Total manometric head HS = Suction height
Q
m³/h l/min
H metres
0
0.3
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
6.0
7.2
70
80
100 120 130
0
5
10
20
30
40
50
60
38
36
35
32.5
29
25
20
15.5 10.5
5
50
48
47
43
28
22.5
16
10
36
35.5
35
33.5
32
30
28
26
23
20
13.5
5
46
45
44
42
40
38
35.5
33
30
26.5
19
10
38.5 32.5
7.8
5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
123
PLURIJET 80-100 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Stainless steel AISI 304
3
IMPELLERS
Noryl GFN2V
4
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
5
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
STA-13
Ø 13 mm
6
BEARINGS
Materials
Pump
8
CAPACITOR
Elastomer
Ceramic
Graphite
NBR
6202 ZZ - C3 / 6201 ZZ 6203 ZZ / 6203 ZZ
Pump
ELECTRIC MOTOR
Rotational ring
Model
PLURIJET 3/80 PLURIJET 3/100 PLURIJET 4/80 PLURIJET 4/100 7
Stationary ring
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
PLURIJETm 3/80 PLURIJETm 4/80 PLURIJETm 3/100 PLURIJETm 4/100
12.5 μF 450 VL
25 μF 250 VL
14 μF 450 VL
25 μF 250 VL
20 μF 450 VL
60 μF 300 VL
PLURIJETm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PLURIJET: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
2
1
124
3
6
5
6
7
4
8
DIMENSIONS AND WEIGHT f
n
a
h1
h
DN1
h2
DN2
w
s n1
MODEL Single-phase
PORTS DN1
Three-phase
PLURIJETm 3/80
–
PLURIJETm 4/80
PLURIJET 4/80
PLURIJETm 3/100
PLURIJET 3/100
PLURIJETm 4/100
PLURIJET 4/100
1”
DIMENSIONS mm
DN2
1”
a
f
110
328
135
351
110
328
135
378
h
h1
172
h2 38
134
191
n
158
kg n1
116
w
2
s
9
61
1~
3~
10.0
–
11.3
10.7
10.5
10.0
13.7
12.7
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
VOLTAGE (three-phase)
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
PLURIJET 4/80
3.4 A
2.0 A
1.1 A
3.3 A
1.9 A
1.1 A
PLURIJET 3/100
3.1 A
1.8 A
1.0 A
3.0 A
1.7 A
1.0 A
PLURIJET 4/100
4.5 A
2.6 A
1.5 A
4.3 A
2.5 A
1.4 A
PLURIJETm 3/80
3.4 A
3.3 A
6.8 A
PLURIJETm 4/80
4.3 A
4.2 A
8.6 A
PLURIJETm 3/100
4.1 A
4.0 A
8.2 A
PLURIJETm 4/100
6.0 A
5.8 A
12.0 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
kg
3~
n° pumps
H (mm)
1~
–
154
2180
1560
–
1760
1670
Single-phase
Three-phase
PLURIJETm 3/80
–
98
1440
980
3~
PLURIJETm 4/80
PLURIJET 4/80
98
1440
1130 1070
154
2180
PLURIJETm 3/100
PLURIJET 3/100
98
1440 1050 1000
154
2180 1640 1560
PLURIJETm 4/100
PLURIJET 4/100
98
1540 1360 1260
140
2140 1940 1800
H
0 80
00
12
125
PLURIJET 90-130-200 Self-priming multi-stage pumps
PERFORMANCE RANGE
•• Flow rate up to 200 l/min (12 m³/h) •• Head up to 97 m
APPLICATION LIMITS
•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 10 bar •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Suitable for use with clean water even where air is present and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming “PLURIJET” pumps are designed to pump water even in cases where air is present. As a result of their quietness, reliability and low energy consumption they are recommended for use in domestic and civil applications such as the pressurisation and distribution of water in combination with pressure sets, and in rain water recovery and irrigation systems, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
PATENTS - TRADE MARKS - MODELS
•• PLURIJET® is a registered trade mark n° 3974301
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency •• IPX5 class protection
GUARANTEE 1 year subject to terms and conditions
126
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
110
5
0
10 5
15
20
10
50 Hz n= 2900 1/min HS= 0 m
25
15
30
20
35
25
40 30
45
50
35
US g.p.m. Imp g.p.m.
40
feet 350
PLURIJET
100 300
90 80 Head H (metres) 4
250
70 200
60 50 40 30
6/90
6/130 5/130
5/90
4/130
150
100
6/200 5/200
3/130
20
4/200 3/200
10 0
0 0
10
20
30
1
40 2
50 3
60
70
80
4
90
100
5
110
6
120 7
130
140
8
150
160
9
170
180
10
190
50
200 l/min
11
12
0
m³/h
Flow rate Q 4 MODEL Single-phase PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 – – PLURIJETm 3/200 PLURIJETm 4/200 – –
POWER
Three-phase PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200
kW 1.1 1.5 1.1 1.5 1.8 2.2 1.1 1.5 1.8 2.2
Q = Flow rate H = Total manometric head HS = Suction height
HP 1.5 2 1.5 2 2.5 3 1.5 2 2.5 3
Q
m³/h
0
l/min
0
76 93 49 65 81 H metres 97 44 58
0.3 5 76 93 49 65 81 97 43.5
0.6
1.2
2.4
3.6
4.8
6.0
10
20
40
60
80
100 130 140 160 180 200
73.5 70 60.5 47 33 90.5 86 74.5 59.5 43 48.5 47.5 45 42.5 38.5 33.5 64 63 60 56 50 43 80.5 79 75 70 62.5 54 96.5 94.5 90 83 74.5 64 43.5 43 42 40.5 38 35
57.5 57.5
57
55
52.5 49.5
7.8
8.4
9.6
10.8 12.0
24 31 39 46 29
27.5
23
18
45
38
35.5
30
24
17
13
73
72
71.5
71
69
65.5
62
56.5
48
44.5
38
30
22
87
86
85.5
85
82
78
73
67
57
53
45
36
26
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
INSTALLATION EXAMPLE
Non-return valve
HS = Suction height
127
PLURIJET 90-130-200 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron and stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1
2
BODY BACKPLATE
Cast iron
3
IMPELLERS
Noryl GFN2V
4
DIFFUSERS
Stainless steel AISI 304, complete with anti-wear ring
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Seal
Shaft
Model
Diameter
FN-18
Ø 18 mm
Materials Stationary ring
Rotational ring
Elastomer
Graphite
Ceramic
NBR
7
BEARINGS
6304 2RS - C3 / 6204 ZZ
8
CAPACITOR
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
31.5 μF 450 VL
60 μF 250 VL
45 μF 450 VL
80 μF 250 VL
PLURIJETm 5/90 PLURIJETm 3/130 PLURIJETm 3/200 PLURIJETm 6/90 PLURIJETm 4/130 PLURIJETm 4/200 9
ELECTRIC MOTOR
PLURIJETm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PLURIJET: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IP X4.
4
1
128
3
2
5
7
8
6
9
7
DIMENSIONS AND WEIGHT f
n
h1
h
DN1
h2
DN2
s w
a
MODEL
n1
PORTS DN1
Single-phase
Three-phase
PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 – – PLURIJETm 3/200 PLURIJETm 4/200 – –
PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200
DIMENSIONS mm
DN2
1¼”
1”
a
f
69
634 665 571 602 634 665 571 602 634 665
h
h1
230
153
h2
46
kg
n
185
n1
w
145
304 335 241 272 304 335 241 272 304 335
s
1~
3~
10
26.6 28.7 24.8 26.9 – – 24.8 26.9 – –
24.8 27.8 22.9 25.9 27.9 28.8 22.9 25.9 27.9 28.8
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 PLURIJETm 3/200 PLURIJETm 4/200
8.5 A 10.5 A 8.5 A 10.5 A 8.5 A 10.5 A
8.2 A 10.0 A 8.2 A 10.0 A 8.2 A 10.0 A
17.0 A 21.0 A 17.0 A 21.0 A 17.0 A 21.0 A
PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200
5.7 A 8.1 A 5.7 A 8.5 A 8.7 A 10.4 A 5.7 A 8.1 A 8.7 A 10.4 A
3.3 A 4.7 A 3.3 A 4.9 A 5.0 A 6.0 A 3.3 A 4.7 A 5.0 A 6.0 A
1.9 A 2.7 A 1.9 A 2.8 A 2.9 A 3.5 A 1.9 A 2.7 A 2.9 A 3.5 A
5.5 A 7.8 A 5.5 A 8.1 A 8.3 A 10.0 A 5.5 A 7.8 A 8.3 A 10.0 A
3.2 A 4.5 A 3.2 A 4.7 A 4.8 A 5.8 A 3.2 A 4.5 A 4.8 A 5.8 A
1.8 A 2.6 A 1.8 A 2.7 A 2.8 A 3.4 A 1.8 A 2.6 A 2.8 A 3.4 A
PALLETIZATION MODEL Three-phase PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200
n° pumps 30 30 40 40 30 30 40 40 30 30
H (mm) 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430
kg 1~ 820 880 1010 1100 – – 1010 1100 – –
3~ 760 850 940 1060 860 880 940 1060 860 880
H
0 80
Single-phase PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 – – PLURIJETm 3/200 PLURIJETm 4/200 – –
GROUPAGE / CONTAINER
00
12
129
F
Standardised “EN 733” centrifugal pumps
PERFORMANCE RANGE
•• Flow rate up to 6000 l/min (360 m³/h) •• Head up to 95 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. pressure in pump body 10 bar (PN10) •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 Pump body dimensions in compliance with EN 733 REGULATION (EU) N. 547/2012
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
130
INSTALLATION AND USE
•• Water supply •• Pressure boosting •• Irrigation •• Water circulation in climatisation sets
•• Cleaning sets •• Firefighting sets •• Industrial applications •• Agricultural applications
The pumps must be installed in enclosed places, or at least protected against inclement weather.
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• Compatibility with hotter or colder liquids •• Compatibility with hotter or colder ambients
GUARANTEE 1 year subject to terms and conditions
PERFORMANCE RANGE 30
50 Hz n= 2900 1/min HS= 0 m
50
100 50
100
200 100
500 200
1600 US g.p.m.
1000 500
1000
1400 Imp. g.p.m. 300
90 F40/250
80
F50/250
F65/250 250
70 F50/200
60
F80/250
F100/250
200
50 150
F32/200H
Head H (metres) 4
40
F32/200
F40/200 F65/200
F80/200 F100/200
H feet 100
30 F50/160
F32/160
20
100 6
200 7
8
9 10
F80/160
F40/160
F50/125
10
F65/160
400
600 30
F65/125
800 1000 40
50
2000 100
50
F100/160
3000 4000 5000 200
300
l/min 400 m 3 /h
Flow rate Q 4
131
F 32/ 160 50 Hz n= 2900 1/min HS= 0 m
H (feet) 25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
8
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
CHARACTERISTIC CURVES AND PERFORMANCE DATA
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase
kW
HP
Fm 32/160C
F 32/160C
1.5
2
Fm 32/160B
F 32/160B
2.2
3
–
F 32/160A
3
4
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
132
0
6
9
12
15
18
21
24
27
400
450
0
100
150
200
250
300
350
25
24
23.5
22
20.5
18
14
31
30
29
28
26
23.5
20.5
17
38
37
36
35
33.5
31.5
30
27.5
24
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 32/200 50 Hz n= 2900 1/min HS= 0 m
H (feet) 25
6
20 15
4
10
2
5
0
0
NPSH (feet)
8
Absorbed power P2 (kW)
A B
P2 (HP)
NPSH (metres)
Head H (metres) 4
CHARACTERISTIC CURVES AND PERFORMANCE DATA
C
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 32/200C
4
5.5
F 32/200B
5.5
7.5
F 32/200A
7.5
10
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
0
6
9
12
15
18
21
24
27
30
0
100
150
200
250
300
350
46
44
43
41.5
40
38
36
400
450
500
34
31.5
52
51
50.5
49
47
45
43
41
38.5
36
60
57
56.5
56
55
53.5
52
50
47
44
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
133
F 32/200H CHARACTERISTIC CURVES AND PERFORMANCE DATA 20
30
40
20
50 Hz n= 2900 1/min HS= 0 m
50
30
60
40
70
50
80 60
70
8
25
6
20 15
4
10
2
5
0 4.5
0 6
AH
NPSH (feet)
H (feet)
F32/200BH
5.5
4
5
BH
3.5
4.5
3
4 3.5
2.5
P2 (HP)
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F32/200AH
3
2 1.5
2.5
50
100
150
200
250
300
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 32/200BH
3
4
F 32/200AH
4
5.5
Q
m³/h
0
6
9
12
15
18
19.2
l/min
0
100
150
200
250
300
320
47
45
44.5
43
40.5
37
57
55
54
52.5
50
46
H metres
Q = Flow rate H = Total manometric head HS = Suction height
134
44
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 40/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F40/160A
H (feet)
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
F40/160C
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F40/160B
Flow rate Q 4
MODEL Single-phase Three-phase Fm 40/160C F 40/160C – F 40/160B – F 40/160A
POWER kW 2.2 3 4
HP 3 4 5.5
Q
m³/h
0
6
9
12
15
18
24
30
36
42
l/min
0
100
150
200
250
300
400
500
600
700
27
27
26.5
26
25.5
25
22.5
19
14
32
32
31.5
31
30.5
30
27.5
24
20
38
38
37.8
37
36.5
36
33.5
30
26
H metres
Q = Flow rate H = Total manometric head HS = Suction height
20
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
135
F 40/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F40/200A
H (feet) 25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
8
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F40/200B
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 40/200B
5.5
7.5
F 40/200A
7.5
10
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
136
0
6
9
12
15
18
24
30
36
42
0
100
150
200
250
300
400
500
600
700
48
47
46.5
46
45.5
44.5
42
38
34
28
56
55
55
55
54.5
54
52.5
49.5
46
41
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 40/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F40/250C
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
H (feet)
F40/250B
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F40/250A
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 40/250C
9.2
12.5
F 40/250B
11
15
F 40/250A
15
20
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
0
6
9
12
0 64
15
18
24
30
100
150
64
63.5
71
71
88
88
36
42
200
250
300
400
63
62.5
62
60
500
600
700
56.5
52.5
47
70.5
70
69.5
69
87.5
87
86.5
86
67
64
60
55
84
81
77
72
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
137
F 50/125 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F50/125A
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
H (feet)
F50/125C
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F50/125B
Flow rate Q 4
MODEL
POWER
Q
m³/h
0
18
24
30
36
42
48
54
60
66
72
Single-phase
Three-phase
kW
HP
0
300
400
500
600
700
800
900
1000
1100
1200
Fm 50/125C
F 50/125C
2.2
3
18.5
17.5
17
16.5
15.5
14.8
13.5
12
10.5
8.2
6
–
F 50/125B
3
4
H metres 21.5
20.7
20
19.5
18.8
17.8
16.5
15
13.5
11.2
9
–
F 50/125A
4
5.5
24.5
23.5
23
22.5
21.8
20.8
19.5
18.3
16.8
15
13
Q = Flow rate H = Total manometric head HS = Suction height
138
l/min
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 50/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F50/160A
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
H (feet)
F50/160C
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F50/160B
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 50/160C
4
5.5
F 50/160B
5.5
7.5
F 50/160A
7.5
10
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
0
18
24
30
36
42
48
54
60
66 1100
0
300
400
500
600
700
800
900
1000
27
27
26.5
25
24.5
23
20
18.5
16
33
32
31.7
31
30
29
27
26
24
21
38
37
36.8
36.5
36
34
33
32
30
27
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
139
F 50/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F50/200AR
H (feet)
F50/200B
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
F50/200C
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F50/200A
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 50/200C
11
15
F 50/200B
15
20
F 50/200A
18.5
25
F 50/200AR
22
30
Q
m³/h
24
36
48
60
72
84
96
102
108
l/min
400
600
800
1000
1200
1400
1600
1700
1800
44
44
44
42
39
36
33
30
52
52
52
50
47
44
40
38
61
61
60.5
60
57
54
50
48
45
69
69
68.5
68
65
62
58
56
53
H metres
Q = Flow rate H = Total manometric head HS = Suction height
140
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 50/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
100 F50/250AR
90 F50/250A
70
F50/250B
60
F50/250C
50
F50/250D
H (feet)
Head H (metres) 4
80
40 30
8
25
6
20 15
4
10
2
5 0
20
P2 (HP)
Absorbed power P2 (kW)
0 25
NPSH (feet)
NPSH (metres)
20
15 10 5
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 50/250D
9.2
12.5
F 50/250C
11
15
F 50/250B
15
20
F 50/250A
18.5
F 50/250AR
22
Q
m³/h l/min
0
18
24
30
36
42
48
54
60
0
300
400
500
600
700
800
900
1000
51
51
49
47
44
41
37
32
59
59
58
57
54
51
47
42
72
72
71
70
69
67
65
62
25
85
85
84
83
82
80
78
76
73
30
95
95
94
93
92
90
88
86
83
H metres
Q = Flow rate H = Total manometric head HS = Suction height
59
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
141
F 65/125 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
H (feet)
F65/125B
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
F65/125C
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F65/125A
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 65/125C
4
5.5
F 65/125B
5.5
7.5
F 65/125A
7.5
10
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
142
0
36
48
60
72
84
96
108
120
132
0
600
800
1000
1200
1400
1600
1800
2000
2200
16
16
16
15.5
14.5
13.5
12.5
11
18
18
18
18
17
16.5
15.5
14.5
13
23
23
23
23
22.5
22.5
22
21
19.5
18
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 65/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F65/160A
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
H (feet)
F65/160C
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F65/160B
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 65/160C
9.2
12.5
F 65/160B
11
15
F 65/160A
15
20
Q
0
36
48
60
72
84
96
108
120
132
144
0
600
800
1000
1200
1400
1600
1800
2000
2200
2400
32
32
32
32
32
30
29
27
25
22
m³/h l/min
H metres
37
36.5
36.5
36
35.5
34
33
31
29
26
23
41
40.5
40.5
40
39.5
39
37.5
36
34
31
28
Q = Flow rate H = Total manometric head HS = Suction height
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
143
F 65/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
200
300
100
400
200
400
600
US g.p.m.
500
Imp g.p.m. feet
F65/200AR
60 70
55
75
175 80
F65/200A
50
Head H (metres) 4
500
300
81
η = 82%
45 F65/200B
150
81
40 125
H (feet)
60
100
0
50 Hz n= 2900 1/min HS= 0 m
35
100
30
25 75
20
6
15
4
10
2
5
0 25
0
30
20 25
15
20 15
10
10
5
0
200
400
0
MODEL
600
800
25
1000
1200
50
POWER
Three-phase
kW
HP
F 65/200B
15
20
F 65/200A
18.5
25
F 65/200AR
22
30
Q
75
m³/h
12
l/min
200
400
44
43.5
50
50
57
57
H metres
1400
1600
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height
144
NPSH (feet)
25
8
P2 (HP)
Absorbed power P2 (kW)
NPSH (metres)
20
24
36
1800
2000
100
2200
2400
125
l/min
2600
m³/h
150
48
60
72
84
96
108
120
132
144
156
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
43.5
43.3
43
42.5
41.5
40
38.5
36.5
34
30.5
50
50
49.5
49
48
46.5
45
43
41
38
36.5
57
57
56
55.5
54.5
53.5
52
50
48
45.5
42
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 65/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
200 100
300 200
400
500
300
700
500
US g.p.m. 600
Imp g.p.m.
58
F65/250A
65
300
70
90
72
F65/250B
Head H (metres) 4
600
400
η=73%
80 F65/250C
72
250
H (feet)
100
100
0
50 Hz n= 2900 1/min HS= 0 m
70
70
200
60
50 150
25
6
20 15
4
10
2
5
Absorbed power P2 (kW)
0
0 60
A
40
B
30
NPSH (feet)
8
50
C
40 30
20
P2 (HP)
NPSH (metres)
40
20
10 0
10
0 0
500 20
1000 40
60
1500
2000
80
100
2500
120
140
l/min 160
m³/h
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 65/250C
30
40
F 65/250B
37
50
F 65/250A
45
60
Q
m³/h
24
40
60
80
100
120
141
150
156
l/min
400
667
1000
1333
1667
2000
2350
2500
2600
76
76
75.5
72.5
68
61.5
53
H metres
Q = Flow rate H = Total manometric head HS = Suction height
87
87
86
84
80
74
66.5
62
94.5
95
94
92
88
82.5
75
71
68
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
145
F 80 /160 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F80/160A
F80/160B
H (feet)
F80/160D
P2 (HP)
Absorbed power P2 (kW)
NPSH (feet)
NPSH (metres)
Head H (metres) 4
F80/160C
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 80/160D
11
15
F 80/160C
15
20
F 80/160B
18.5
25
F 80/160A
22
30
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
146
0
30
60
90
120
150
180
210
240
0
500
1000
1500
2000
2500
3000
3500
4000
25
25
25
24.5
23.5
21
18
14.5
10
30
30
30
29.5
28.5
26
23
19.5
15
35
35
35
34.5
33.5
31
28.5
24.5
20
40
40
40
39.5
38.5
36
33
29.5
25
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 80/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
70
200
0
400
50 Hz n= 2900 1/min HS= 0 m
600
200
800
400
1000
600
800
1200
US g.p.m.
1000
Imp g.p.m. 220
F80/200A 200
60 F80/200B
50
160
140
H (feet)
Head H (metres) 4
180
40 120
100
30
80
25
6
20 15
4
10
2
5
Absorbed power P2 (kW)
0
0
40
50
A
30
40
B
30
20
20
10
0
NPSH (feet)
8
P2 (HP)
NPSH (metres)
20
10
0
500
1000
0
1500
50
2000 100
2500
3000
150
3500 200
4000
4500
l/min m³/h
250
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 80/200B
30
40
F 80/200A
37
50
Q
m³/h
30
50
100
150
200
219
234
l/min
500
833
1667
2500
3333
3650
3900
56
56
54
49
41
34.5
62
62
61
57
50
45.5
H metres
Q = Flow rate H = Total manometric head HS = Suction height
40
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
147
F 80/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
100
200
0
400
50 Hz n= 2900 1/min HS= 0 m
600
200
800
400
1000
600
800
1200
US g.p.m.
1000
Imp g.p.m. 320
90
F80/250A
70
280
75 76
F80/250B
η=77% 240 75
70
71 69
200
60
50
H (feet)
Head H (metres) 4
80
160
40 120
25
6
20 15
4
10
2
5
0 60
0 80
A
NPSH (feet)
8
50 60
B
40 30
40
P2 (HP)
Absorbed power P2 (kW)
NPSH (metres)
30
20 20
10 0
0
500
0
1000
1500
50
2000
2500
100
3000
150
3500 200
4000
4500
l/min
0
m³/h
250
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 80/250B
45
60
F 80/250A
55
75
Q
m³/h
36
l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
148
50
100
150
200
216
234
600
833
1667
2500
3333
3600
3900
77
77.5
76
70.5
58.5
54
88.5
89.5
89
83
72
68
60
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 100/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F100/160A 65
F100/160B
69
70
F100/160C
Head H (metres) 4
71
H (feet)
η = 75% 71 70 69
NPSH (feet)
NPSH (metres)
65
Absorbed power P2 (kW)
A
P2 (HP)
B C
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 100/160C
15
20
F 100/160B
18.5
25
F 100/160A
22
30
Q
m³/h
60
120
180
240
270
300
330
360
l/min
1000
2000
3000
4000
4500
5000
5500
6000
28
25.5
22
17.5
15
12
32
30
27
22.5
19.5
17
13
35
34
31
27
24.5
22
18
H metres
Q = Flow rate H = Total manometric head HS = Suction height
15
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
149
F 100/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA 200
0
65
400
600
200
0
800
400
F100/200A
50 Hz n= 2900 1/min HS= 0 m 1000
600
1400
1000
US g.p.m. 1200 Imp. g.p.m.
60
200
71
60
75
F100/200B
79
55
80.5
180
η = 81%
F100/200C
50
160 80.5
45
79
80.5
140
H (feet)
Head H (metres) 4
1200
800
75
40
79
120
35
30
100
71
25
6
20 15
4
10
2
5
Absorbed power P2 (kW)
0 50
NPSH (feet)
8
0 60
A
40
50
B C
30
40 30
20
P2 (HP)
NPSH (metres)
25
20
10 0
10
0
500
1000
1500
50
0
2000 100
2500
3000
150
3500
4000
200
4500
5000
250
5500 l/min
300
m³/h
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 100/200C
30
40
F 100/200B
37
50
F 100/200A
45
60
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
150
0
50
100
150
200
250
279
294
300
315
0
833
1667
2500
3333
4167
4650
4900
5000
5250
51
51
50
47
41.5
34
28 41.5
38
57
57
56
53
48
41
36
33
63
63
62.5
60
56
50
45
42.5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 100/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
100
200
0
400
600
200
50 Hz n= 2900 1/min HS= 0 m
800
400
1000
600
1200
800
1400
1000
1600
US g.p.m. Imp g.p.m.
1200
300
90
65
F100/250A
72
75 78
η = 80% 250
F100/250B 78
70
75
η = 79.5%
200
71
60
H (feet)
Head H (metres) 4
80
50 150
40
100
6
20
4
10
2
Absorbed power P2 (kW)
0 80
NPSH (feet)
30
8
0
A
60
100
80
B
60
40
P2 (HP)
NPSH (metres)
30 10
40
20
0 0
500
1000
1500
50
2000
2500
100
3000
150
3500 200
4000
4500
5000
250
5500
300
6000 350
l/min m³/h
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 100/250B
55
75
F 100/250A
75
100
Q
m³/h
48
96
150
180
210
240
300
309
345
l/min
800
1600
2500
3000
3500
4000
5000
5150
5750
75
75
74
71.5
69
64.5
51
48
89
89
88.5
87
84
80.5
70.5
69
H metres
Q = Flow rate H = Total manometric head HS = Suction height
58
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
151
F POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with flanged suction and delivery ports
2
COUNTERFLANGES
Steel, complete with ISO 228/1 thread
3a
BODY BACKPLATE
Cast iron
3b
MOTOR BRACKET
Cast iron
4
IMPELLER
Brass for F32/160, F32/200, F40/160, F40/200, F50/125, F50/160 Cast iron for F40/250, F50/200, F50/250, F65/125, F65/160, F65/200, F65/250, F80/160, F80/200, F80/250, F100/160, F100/200, F100/250
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
FN-20
F32/160 F50/125 F32/200 F50/160 F50/200 F65/200 F100/160 F40/250 F65/250 F80/250B F80/250A 7
BEARINGS
Pump F32/160C F32/160B F40/160C F50/125C Fm32/160B F32/160A Fm40/160C F40/160B Fm50/125C F50/125B F40/160A F50/125A
8
9
CAPACITOR
ELECTRIC MOTOR
F40/160 F40/200 F65/125 F65/160 F80/160 F50/250 F80/200 F100/200 F100/250
Rotational ring
Elastomer
Ø 20 mm
Graphite
Ceramic
NBR
FN-24
Ø 24 mm
Graphite
Ceramic
NBR
FN-32 NU
Ø 32 mm
Graphite
Ceramic
NBR
FN-38
Ø 38 mm
Graphite
Ceramic
NBR
FN-40 NU
Ø 40 mm
Graphite
Ceramic
NBR
FH-45 NU
Ø 45 mm
Graphite
Ceramic
NBR
Model
6206 ZZ - C3 / 6204 ZZ
6206 ZZ - C3 / 6205 ZZ
6306 ZZ - C3 / 6206 ZZ - C3
Pump
Materials Stationary ring
Pump F32/200 F40/200 F50/160 F65/125 F40/250 F50/200 F50/250 F65/160 F65/200 F80/160 F100/160 F65/250 F80/200 F80/250B F100/200 F80/250A F100/250
Model 6307 ZZ - C3 / 6206 ZZ - C3
6310 ZZ - C3 / 6308 ZZ - C3
6312 ZZ - C3 / 6212 ZZ - C3 6314 ZZ - C3 / 6314 ZZ - C3
Capacitance
Single-phase
(230 V or 240 V)
Fm32/160C Fm32/160B Fm40/160C Fm50/125C
45 μF 450 VL 70 μF 450 VL 70 μF 450 VL 70 μF 450 VL
Fm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding (up to 1.5 kW) F: three-phase 230/400 V - 50 Hz up to 4 kW 400/690 V - 50 Hz from 5.5 to 75 kW ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class – Protection: IPX5
152
7
7
8
2
1
4
3a
6
5
9
Single-phase version
7
7
2
1
4
6
3b
5
9
Three-phase version
153
F DIMENSIONS AND WEIGHT f
n
a
h1
DN1
h
h2
DN2
w1 w2
n1
s
n2
MODEL Single-phase
Three-phase
Fm 32/160C Fm 32/160B – – – – – – Fm 40/160C – – – – – – – Fm 50/125C – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
F 32/160C F 32/160B F 32/160A F 32/200C F 32/200B F 32/200A F 32/200BH F 32/200AH F 40/160C F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A F 50/125C F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 80/160D F 80/160C F 80/160B F 80/160A F 100/160C F 100/160B F 100/160A
154
PORTS DN1
50
DN2
DIMENSIONS mm a
f 412 448/412 448 469
32 80
h
h1
h2
n
292
132
160
242
340
160
180
270
448/412 448 465
292
132
160
240
535
340
160
180
405
180
292
132
515
n1
kg * n2
190
240
275
212
265
225
328
250
320
160
242
190
240
180
269 212
265
200
316
225
337
250
320
180
291 212
280
200
300
250
320
280
360
469
65
40
606 701 465/431 465 484 489 535 65
340
616
50
711 100
160 360
743 606 701
405
180
733 511 557
340 160
80
621
65
360
716 719 751 652 100
80
100
405
180
225
747 125
125
340
330
779 758 790
480
200
280
362
w1
w2
s
1~
3~
39.2 37.0 42.6 38.5 – 42.6 – 52.0 – 57.0 – 61.0 – 47.9 35 35 – 51.1 43.9 40.0 – 44.0 – 50.1 – 61.0 – 67.0 – 103.0 47.5 47.5 – 109.0 – 125.0 44.2 40.1 – 44.1 – 50.7 – 55.0 – 60.6 35 35 – 64.7 14 – 106.0 – 128.0 – 135.0 – 147.0 – 106.0 – 113.4 – 129.6 – 146.0 – 155.0 – 62.7 – 66.8 – 74.0 – 100.0 47.5 47.5 – 106.5 – 123.0 – 128.0 – 125.0 – 153.1 – 111.5 – 126.0 – 143.5 – 153.0 – 139.0 60 60 18 – 153.7 – 165.0 (*weight includes counterflanges)
DIMENSIONS AND WEIGHT f a DN2
h1
DN1
h
h2
n
h3
s w
32 40 50 65 80 100 125
D mm 140 150 165 185 200 220 250
K mm 100 110 125 145 160 180 210
a
f
h
DN
FLANGES
MODEL
n1 n2
m
HOLES N° Ø (mm) FLANGES
4 18
DN K D
8
PORTS
Three-phase F 65/250C F 65/250B F 65/250A F 80/200B F 80/200A F 80/250B F 80/250A F 100/200C F 100/200B F 100/200A F 100/250B F 100/250A
DN1 80
DIMENSIONS mm
DN2 65
100
100
80 125
125
100 140
796 847 847 824 875 872 1015 824 875 875 1036
h1
h2
h3
450 200
n
15
369
25
360
280
12 55
250
430
kg * n1
n2
w
m
s
318
360
269.5
305
18.5
380 490
400
490
294
350
24
480 620
250
480
200
280
0
391
318
360
269.5
305
18.5
620
250
280
45
490
400
490
300
350
24
3~ 210.0 230.0 230.0 212.0 222.5 245.0 497.0 208.5 239.0 240.0 498.5 498.5
(*weight includes counterflanges)
COUNTERFLANGES DN FLANGES
F COUNTERFLANGES
D mm
K mm
32 40 50 65 80 100 125
1¼" 1½" 2" 2½" 3" 4" 5"
140 150 165 185 200 220 250
100 110 125 145 160 180 210
HOLES N°
Ø (mm)
4 18 8
F K D
155
F ABSORPTION MODEL Single-phase Fm 32/160C Fm 32/160B Fm 40/160C Fm 50/125C
VOLTAGE (single-phase) 230 V 11.0 A 15.0 A 15.0 A 15.0 A
CAPACITOR
Single-phase version
Three-phase version
156
240 V 10.0 A 13.8 A 13.8 A 13.8 A
MODEL Three-phase F 32/160C F 32/160B F 32/160A F 32/200C F 32/200B F 32/200A F 32/200BH F 32/200AH F 40/160C F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A F 50/125C F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 65/250C F 65/250B F 65/250A F 80/160D F 80/160C F 80/160B F 80/160A F 80/200B F 80/200A F 80/250B F 80/250A F 100/160C F 100/160B F 100/160A F 100/200C F 100/200B F 100/200A F 100/250B F 100/250A
VOLTAGE (three-phase) 230÷240 V
400÷415 V
690÷720 V
7.5 A 10.0 A 12.0 A 17.9 A – – 12.6 A 15.4 A 9.9 A 12.0 A 17.2 A – – – – – 9.4 A 12.0 A 16.3 A 15.8 A – – – – – – – – – – – 17.5 A – – – – – – – – – – – – – – – – – – – – – – – – – – –
4.3 A 5.8 A 7.3 A 10.3 A 11.7 A 14.9 A 7.3 A 8.9 A 5.7 A 6.9 A 9.9 A 12.6 A 15.6 A 21.0 A 23.5 A 30.5 A 5.4 A 6.9 A 9.4 A 9.1 A 12.3 A 15.5 A 23 A 29.5 A 34.5 A 41.5 A 17.2 A 21.0 A 27.0 A 34.0 A 41.0 A 10.0 A 12.0 A 16.5 A 19.0 A 23.0 A 27.5 A 31.0 A 34.0 A 41.0 A 53.0 A 65.0 A 79.0 A 22.0 A 29.0 A 34.5 A 39.0 A 53.0 A 65.0 A 79.0 A 98.0 A 31.0 A 36.0 A 42.0 A 53.0 A 65.0 A 79.0 A 98.0 A 126.0A
2.5 A 3.4 A 4.2 A 5.9 A 6.7 A 8.6 A 4.2 A 5.1 A 3.3 A 4.0 A 5.7 A 7.3 A 9.0 A 12.1 A 13.6 A 17.6 A 3.1 A 4.0 A 5.4 A 5.3 A 7.1 A 8.9 A 13.3 A 17 A 20 A 24 A 9.9 A 12.0 A 15.6 A 19.6 A 24.0 A 5.8 A 7.0 A 9.5 A 11.0 A 13.5 A 16.0 A 18.0 A 19.5 A 23.7 A 31.0 A 38.0 A 46.0 A 13.0 A 17.0 A 20.0 A 22.5 A 31.0 A 38.0 A 46.0 A 57.0 A 18.0 A 21.0 A 24.0 A 31.0 A 38.0 A 46.0 A 57.0 A 73.0 A
PALLETIZATION MODEL
GROUPAGE
Fm 32/160C Fm 32/160B – – – – – – Fm 40/160C – – – – – – – – Fm 50/125C – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
F 32/160C F 32/160B F 32/160A F 32/200C F 32/200B F 32/200A F 32/200BH F 32/200AH – F 40/160C F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A – F 50/125C F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 65/250C F 65/250B F 65/250A F 80/160D F 80/160C F 80/160B F 80/160A F 80/200B F 80/200A F 80/250B F 80/250A F 100/160C F 100/160B F 100/160A F 100/200C F 100/200B F 100/200A F 100/250B F 100/250A
18 18 18 12 12 12 12 12 12 18 18 12 12 12 6 6 6 18 12 18 12 12 12 12 6 6 6 6 6 6 6 6 6 12 12 12 6 6 6 6 6 6 1 1 1 6 6 6 6 1 1 1 1 6 6 6 1 1 1 1 1
1~
3~
n° pumps
1430 1430 1430 1535 1535 1535 1535 1535 1400 1430 1430 1400 1535 1535 1200 1200 1200 1430 1400 1430 1535 1535 1535 1535 1200 1200 1200 1380 1200 1200 1200 1200 1380 1535 1535 1535 1200 1200 1200 1200 1200 1380 450 450 450 1200 1380 1380 1380 450 450 450 770 1380 1380 1380 450 450 450 770 770
730 781 – – – – – – 509 – – – – – – – – 820 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
683 707 784 641 701 749 591 629 – 735 809 617 749 821 635 671 767 – 498 810 625 677 744 793 653 785 827 899 653 697 794 893 947 769 818 905 617 656 755 785 767 936 227 247 247 686 773 878 935 229 240 262 514 851 939 1007 226 256 257 516 516
24 24 24 16 16 16 16 16 16 24 24 16 16 16 9 9 9 24 16 24 16 16 16 16 9 9 9 9 9 9 9 9 9 16 16 16 9 9 9 9 9 9 – – – 9 9 9 9 – – – – 9 9 9 – – – – –
H (mm)
kg 1~
3~
1860 967 905 1860 1036 936 1860 – 1040 2000 – 849 2000 – 929 2000 – 993 2000 – 783 2000 – 833 1820 673 – 1860 – 975 1860 – 1073 1820 – 817 2000 – 993 2000 – 1089 1730 – 944 1730 – 998 1730 – 1142 1860 1088 – 1820 – 659 1860 – 1075 2000 – 828 2000 – 897 2000 – 987 2000 – 1052 1730 – 971 1730 – 1169 1730 – 1232 200 – 1340 1730 – 971 1730 – 1037 1730 – 1183 1730 – 1331 2000 – 1412 2000 – 1020 2000 – 1085 2000 – 1201 1730 – 917 976 1730 – 1730 – 1018 1730 – 1169 1730 – 1142 2000 – 1395 – – – – – – – – – 1730 – 1021 2000 – 1151 2000 – 1309 2000 – 1394 – – – – – – – – – – – – 2000 – 1256 2000 – 1437 2000 – 1502 – – – – – – – – – – – – – – –
H
0
Three-phase
CONTAINER kg
H (mm)
80
Single-phase
n° pumps
00
12
157
F-I Stainless steel standardised “EN 733” pumps
PERFORMANCE RANGE
•• Flow rate up to 2200 l/min (132 m³/h) •• Head up to 38 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. pressure in pump body 10 bar (PN10) •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 Pump body dimensions in compliance with: EN 733
INSTALLATION AND USE
•• Water supply •• Pressure boosting •• Irrigation •• Water circulation in climatisation sets
Suitable for use with clean, aggressive liquids that are chemically compatible with the materials from which the pump is made. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Other voltages or 60 Hz frequency •• Compatibility with hotter or colder liquids •• Compatibility with hotter or colder ambients
REGULATION (EU) N. 547/2012
GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
158
•• Cleaning sets •• Firefighting sets •• Industrial applications •• Agricultural applications
1 year subject to terms and conditions
PERFORMANCE RANGE 30
50 Hz n= 2900 1/min HS= 0 m 50
100 50
50
200
US g.p.m.
500
100
200
500
Imp. g.p.m. feet 150
40
F50/160-I
Head H (metres) 4
30
100
F65/125-I
20
50
10
100 6
200 7
8
9
10
400
600 30
800 40
50
2000
1000 100
l/min m 3/h
Flow rate Q 4
159
F 50/160-I CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
F50/160A-I
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
H (feet)
F50/160C-I
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F50/160B-I
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 50/160C-I
4
5.5
F 50/160B-I
5.5
7.5
F 50/160A-I
7.5
10
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
160
0
18
24
30
36
42
48
54
60
66 1100
0
300
400
500
600
700
800
900
1000
27
27
26.5
25
24.5
23
20
18.5
16
33
32
31.7
31
30
29
27
26
24
21
38
37
36.8
36.5
36
34
33
32
30
27
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
F 65/125-I CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
H (feet)
F65/125B-I
8
25
6
20 15
4
10
2
5
0
0
P2 (HP)
NPSH (feet)
F65/125C-I
Absorbed power P2 (kW)
NPSH (metres)
Head H (metres) 4
F65/125A-I
Flow rate Q 4
MODEL
POWER
Three-phase
kW
HP
F 65/125C-I
4
5.5
F 65/125B-I
5.5
7.5
F 65/125A-I
7.5
10
Q
m³/h l/min
H metres
Q = Flow rate H = Total manometric head HS = Suction height
0
36
48
60
72
84
96
108
120
132
0
600
800
1000
1200
1400
1600
1800
2000
2200
16
16
16
15.5
14.5
13.5
12.5
11
18
18
18
18
17
16.5
15.5
14.5
13
23
23
23
23
22.5
22.5
22
21
19.5
18
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
161
F-I POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 316, complete with flanged suction and delivery ports
2
BODY BACKPLATE
Stainless steel AISI 316
4
IMPELLER
Stainless steel AISI 316
5
MOTOR SHAFT
Stainless steel AISI 316
6
MECHANICAL SEAL
Pump
Seal
Shaft
Model
Model
Diameter
F50/160-I F65/125-I
FN-24SV
Ø 24 mm
7
9
BEARINGS
ELECTRIC MOTOR
Pump
Model
F50/160-I F65/125-I
6307 ZZ - C3 / 6206 ZZ - C3
Materials Stationary ring
Rotational ring
Elastomer
Silicon carbide
Silicon carbide
Viton
F: three-phase 230/400 V - 50 Hz for 4 kW. 400/690 V - 50 Hz from 5.5 to 7.5 kW. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class. – Protection: IPX5.
6
1
162
3
2
5
6
4
7
DIMENSIONS AND WEIGHT f
n
a
h1
h
DN1
h2
DN2
s
n1
w1 w2
n2
MODEL Three-phase
PORTS DN1
DIMENSIONS mm
DN2
a
f
F 50/160C-I F 50/160B-I
h1
h2
n
n1
kg n2
w1
w2
s
65
50 100
80
269
535
F 65/125C-I
511
65
340
160
180
265
35
54.0
35
212 291
557
F 65/125A-I
3~ 50.2
489
F 50/160A-I F 65/125B-I
h
14 280
47.5
65.5 62.6 67.7
47.5
72.9
ABSORPTION MODEL
VOLTAGE (three-phase)
Three-phase
230÷240 V
400÷415 V
690÷720 V
F 50/160C-I F 50/160B-I F 50/160A-I F 65/125C-I F 65/125B-I F 65/125A-I
15.8 A – – 17.5 A – –
9.1 A 12.3 A 15.5 A 10.0 A 12.0 A 16.5 A
5.3 A 7.1 A 8.9 A 5.8 A 7.0 A 9.5 A
PALLETIZATION GROUPAGE
MODEL
CONTAINER
n° pumps
H (mm)
kg 3~
n° pumps
H (mm)
kg 3~
F 50/160C-I
12
1535
619
16
2000
820
F 50/160B-I
12
1535
665
16
2000
881 1064
Three-phase
12
1535
802
16
2000
12
1535
768
16
2000
1018
F 65/125B-I
12
1535
829
16
2000
1100
F 65/125A-I
12
1535
891
16
2000
1183
0 80
F 50/160A-I F 65/125C-I
H
00
12
163
FG Standardised “EN 733” centrifugal pumps
PERFORMANCE RANGE
•• Flow rate up to 6000 l/min (360 m³/h) •• Head up to 95 m
APPLICATION LIMITS
•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Max. pressure in pump body 10 bar (PN10)
CONSTRUCTION AND SAFETY STANDARDS EN 733
INSTALLATION AND USE
•• Water supply •• Pressure boosting •• Irrigation •• Water circulation in climatisation sets
•• Cleaning sets •• Firefighting sets •• Industrial applications •• Agricultural applications
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Counterflange •• Pumps compatible with 60 Hz motors •• Compatibility with hotter or colder liquids •• Compatibility with hotter or colder ambients
REGULATION (EU) N. 547/2012
GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
164
1 year subject to terms and conditions
FG2
n= 2900 1/min
PERFORMANCE RANGE 30
HS= 0 m
50
100 50
100 90
200 100
500 200
1000 500
1000
1400 Imp. g.p.m. 300
50
FG2-65/250
FG2-50/200
FG2-80/250
0/2
FG2-40/250
200
FG 2
60
-10
70
50
150
-10 FG2-65/160
FG2-65/125
6
7
8
400
9 10
600 30
800
40
100
FG2-80/160
50
FG2-100/160
FG2-50/125
200
H feet
FG2
FG2
FG2-50/160
20
10 100
00
FG2-40/160
FG2-80/200
0/2
FG2-32/160
0
30
FG2-65/200
/20
FG2-32/200
-40
40
FG2-32/200H
1000
2000
50
Flow rate Q 4
3000
100
4000 5000
200
300
PERFORMANCE DATA MODEL
FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2
US g.p.m.
FG2-50/250
80
Head H (metres) 4
1600
pump
32/160 C 32/160 B 32/160 A 32/200 C 32/200 B 32/200 A 32/200 BH 32/200 AH 40/160 C 40/160 B 40/160 A 40/200 B 40/200 A 40/250 C 40/250 B 40/250 A 50/125 C 50/125 B 50/125 A 50/160 C 50/160 B 50/160 A 50/200 C 50/200 B 50/200 A 50/200 AR 50/250 D 50/250 C 50/250 B 50/250 A 50/250 AR
400
m3/h
HS= 0 m
MOTOR PAIRING kW HP 1.5 2.2 3 4 5.5 7.5 3 4 2.2 3 4 5.5 7.5 9.2 11 15 2.2 3 4 4 5.5 7.5 11 15 18.5 22 9.2 11 15 18.5 22
l/min
2 3 4 5.5 7.5 10 4 5.5 3 4 5.5 7.5 10 12.5 15 20 3 4 5.5 5.5 7.5 10 15 20 25 30 12.5 15 20 25 30
PERFORMANCE
Q m³/h
H metres
6 ÷ 21 6 ÷ 24 6 ÷ 27 6 ÷ 27 6 ÷ 30 6 ÷ 30 6 ÷ 18 6 ÷ 19.2 6 ÷ 36 6 ÷ 36 6 ÷ 42 6 ÷ 42 6 ÷ 42 6 ÷ 42 6 ÷ 42 6 ÷ 42 18 ÷ 72 18 ÷ 72 18 ÷ 72 18 ÷ 60 18 ÷ 66 18 ÷ 66 24 ÷ 102 24 ÷ 102 24 ÷ 108 24 ÷ 108 18 ÷ 54 18 ÷ 54 18 ÷ 60 18 ÷ 60 18 ÷ 60
24 ÷ 14 30 ÷ 17 37 ÷ 24 44 ÷ 31.5 51 ÷ 36 57 ÷ 44 45 ÷ 37 55 ÷ 44 27 ÷ 14 32 ÷ 20 38 ÷ 20 47 ÷ 28 55 ÷ 41 64 ÷ 47 71 ÷ 55 88 ÷ 72 17.5 ÷ 6 20.7 ÷ 9 23.5 ÷ 13 27 ÷ 16 32 ÷ 21 37 ÷ 27 44 ÷ 30 52 ÷ 38 61 ÷ 45 69 ÷ 53 51 ÷ 32 59 ÷ 42 72 ÷ 59 85 ÷ 73 95 ÷ 83
MODEL pump FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2 FG2
65/125 C 65/125 B 65/125 A 65/160 C 65/160 B 65/160 A 65/200 B 65/200 A 65/200 AR 65/250 C 65/250 B 65/250 A 80/160 D 80/160 C 80/160 B 80/160 A 80/200 B 80/200 A 80/250 B 80/250 A 100/160 C 100/160 B 100/160 A 100/200 C 100/200 B 100/200 A 100/250 B 100/250 A
MOTOR PAIRING kW HP 4 5.5 7.5 9.2 11 15 15 18.5 22 30 37 45
11
15 18.5 22 30 37 45 55 15 18.5 22 30 37 45 55 75
5.5 7.5 10 12.5 15 20 20 25 30 40 50 60 15 20 25 30 40 50 60 75 20 25 30 40 50 60 75 100
PERFORMANCE Q m³/h
H metres
36 ÷ 108 36 ÷ 108 36 ÷ 132 36 ÷ 132 36 ÷ 144 36 ÷ 144 12 ÷ 144 12 ÷ 156 12 ÷ 156 24 ÷ 141 24 ÷ 150 24 ÷ 156 30 ÷ 240 30 ÷ 240 30 ÷ 240 30 ÷ 240 30 ÷ 219 30 ÷ 234 36 ÷ 216 36 ÷ 234 60 ÷ 300 60 ÷ 330 60 ÷ 360 48 ÷ 279 48 ÷ 294 48 ÷ 315 48 ÷ 309 48 ÷ 345
16 ÷ 11 18 ÷ 13 23 ÷ 18 32 ÷ 22 36.5 ÷ 23 40.5 ÷ 28 44 ÷ 30.5 50 ÷ 36.5 57 ÷ 42 76 ÷ 53 87 ÷ 62 94.5 ÷ 68 25 ÷ 10 30 ÷ 15 35 ÷ 20 40 ÷ 25 56 ÷ 34.5 62 ÷ 40 77 ÷ 54 88.5 ÷ 60 28 ÷ 12 32 ÷ 13 35 ÷ 15 51 ÷ 28 57 ÷ 33 63 ÷ 38 75 ÷ 48 89 ÷ 58
165
FG2
n= 2900 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG2 32/160
FG2 32/200 60
40
FG32/200A
FG32/160A 51
55
57
58
FG32/160B
η = 62% 60
FG32/160C
58
Ø 169
57
20
55
50
52 53
FG32/200B
50
60
H (m)
H (m)
30
45
55
45
54 η = 55% 54
FG32/200C
Ø 209
40 Ø 196
35
51
54
Ø 155
10
3
6
9
12
15
18
21
24
27
3
25
30
Ø 169
P2 (kW)
P2 (kW)
Ø 155
A
1.5 3
B C
Ø 143
6
9
12
15
18
21
24
27
18
24
30
36
NPSH (m)
Ø 169
4 2 3
6
9
12
15
18
Q (m³/h)
21
Ø 196
5
Ø 184
4
24
2
30
6
NPSH (m)
12
Ø 209
A
3
27
B C
0
6
12
18
24
30
8
36
Ø 209
4 0
30
FG2 32/200H
0
6
12
18
24
Q (m³/h)
30
36
FG2 40/160
60
50
55 FG32/200AH
40
43
45
50
48 50
40
51.5
FG40/160A
η = 53.5%
FG32/200BH
45
30
Ø 205
40 Ø 192
35
55
FG40/160B
H (m)
H (m)
6
6
2
0
0
7
2.5
1
Ø 184
30
Ø 143
60 62
64
FG40/160C
η = 65% 64
62
65
60 Ø 169
20
Ø 157 Ø 148
30
10
25 3
6
9
12
15
18
4.5
3
AH
2.5
BH
2
NPSH (m)
3
6
9
12
15
18
8
Ø 205
3
6
9
12
Q (m³/h)
15
18
6
12
18
24
30
36
42
21
48
Ø 169 Ø 157
3
Ø 148
A
2 1
21
4 0
166
P2 (kW)
P2 (kW)
Ø 192
3.5
0
4
Ø 205
4
1.5
0
21
NPSH (m)
20
B C
0
6
12
18
24
30
36
8
42
48
Ø 169
4 0
0
6
12
18
24
Q (m³/h)
30
36
42
48
FG2
n= 2900 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG2 40/200
FG2 40/250 100
60 FG40/200A
55 57
FG40/250A
90
59 63
FG40/200B
η = 64% 63 Ø 205
40
40
44
80
H (m)
H (m)
50
50
59
46
48
FG40/250B
70
50 η = 51% Ø 260
FG40/250C
60
57 55
30
54
Ø 188
20
0
4
8
12
16
20
24
28
32
36
40
8
44
30
48
4
8
12
P2 (kW)
Ø 188
5 4
A
3
B
0
4
8
12
16
20
24
28
32
36
40
44
28
32
36
40
44
4
Ø 205
0
4
Ø 233
10
Ø 223
A
8
8
12
16
20
24
Q (m³/h)
28
32
36
40
44
4
48
8
48
B C
4
8
12
25
35
0
4
8
12
70
73
68
70
10
63
36
32
36
40
44
48
28
32
36
40
44
48
67
42
48
54
60
70
72
78
72
78
72
78
η = 71% 70
66
72
67
71
25
Ø 171
64
Ø 161
62 Ø 152
15 10 12 7.5
78
Ø 145
18
24
30
36
42
48
54
60
66 Ø 171
6.5
3.5
2.5
A
2
B
P2 (kW)
Ø 138
3
Ø 126
C
18
24
30
36
42
48
54
60
66
72
18
24
30
36
42
48
Q (m³/h)
54
60
66
72
4.5
2.5 12
78
NPSH (m)
Ø 145
4
5.5
3.5
8
0 12
62 64
20
Ø 126
5
1.5 12
24
Q (m³/h)
Ø 145 Ø 138
30
20
FG50/160C
70
24
28
30
η = 70%
H (m)
FG50/125C
18
16
FG50/160B
68
15
0 12 4
24
Ø 260
63
FG50/125B
20
FG2 50/160 40
FG50/125A
16
4 0
48
0
8
30
20
H (m)
24
12
FG50/160A
P2 (kW)
20
Ø 260
6
FG2 50/125
NPSH (m)
16
14
NPSH (m)
P2 (kW) NPSH (m)
0
16
Ø 205
6
0
Ø 223
40
7
2
Ø 233
50
78
Ø 161 Ø 152
A B C
18
24
30
36
42
48
54
60
66
8 4 0 12
Ø 171
18
24
30
36
42
48
Q (m³/h)
54
60
66
167
FG2
n= 2900 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG2 50/200
FG2 50/250 100
75 FG50/200AR
65
62
65 67
90
68
FG50/200A
70
69
FG50/200B
Ø 224
FG50/200C
H (m)
H (m)
45
67
54 57
59
η = 61% Ø 261
36
48
60
72
84
96
FG50/250B
Ø 248
FG50/250C
Ø 235
FG50/250D 55 Ø 213
50
30
Ø 185
24
52
FG50/250A
40
Ø 200
35
60 50
Ø 215
68
25 12 25
50
80 η = 70%
55
FG50/250AR
108
Ø 204
20 12 25
120
18
24
30
36
42
48
54
60 Ø 261
Ø 224
5 12
Ø 185
AR A B C
24
36
48
60
72
84
96
108
4 24
36
48
60
72
Q (m³/h)
84
96
108
5 12
120
Ø 224
0 12
15 10
8
NPSH (m)
P2 (kW)
Ø 200
15 10
20
Ø 215
NPSH (m)
P2 (kW)
20
FG2 65/125
AR A B C D
Ø 213 Ø 204
18
24
30
36
42
48
54
60
8
66
Ø 261
4 18
24
30
36
42
48
Q (m³/h)
54
60
66
FG2 65/160 50
25 FG65/125A
70
73
75 80
40
η = 81%
20 FG65/125B
80
H (m)
H (m)
Ø 248 Ø 235
0 12
120
66
Ø 137
FG65/125C
15
FG65/160A
72
78
FG65/160B
80
η = 81% 80
FG65/160C
30
79 Ø 172 Ø 163
75
Ø 156
20
73
Ø 125
10 24 9
Ø 116
36
48
60
72
84
96
108
120
132
144
10 24 16
156
Ø 125
NPSH (m)
3 24
A B C
36
48
60
72
84
96
108
120
132
144
4 48
60
72
84
96
Q (m³/h)
108
120
132
4 24
156
Ø 137
36
10 7
Ø 116
8
0 24
168
P2 (kW)
7 5
48
60
72
84
96
108
120
132
144
156
Ø 172
13
NPSH (m)
P2 (kW)
Ø 137
36
144
156
Ø 163 Ø 156
A B C
36
48
60
72
84
96
108
120
132
8
144
156
Ø 172
4 0 24
36
48
60
72
84
96
Q (m³/h)
108
120
132
144
156
FG2
n= 2900 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG2 65/200
100
FG65/200AR
60
55
70
75 80
FG65/200A
50
H (m)
Ø 210
40
Ø 204
35 30
0
12
24
36
48
60
72
84
40
96 108 120 132 144 156 168
Ø 232
0
24
48
72
96
120
144
168
P2 (kW)
15
Ø 191
AR A B
0
30
Ø 232
20
A B C
10
12
24
36
48
60
72
84
Ø 210
4 12
24
36
48
60
72
84
0
96 108 120 132 144 156 168
8
0
Ø 258 Ø 248
40
NPSH (m)
P2 (kW)
Ø 204
10
NPSH (m)
Ø 258 Ø 248
50 Ø 210
0
24
48
72
96
120
144
8
168 Ø 258
4 0
96 108 120 132 144 156 168
Q (m³/h)
FG2 80/160
0
24
48
72
96
120
Q (m³/h)
144
168
FG2 80/200
45
70 FG80/160A
35
FG80/160B
70
76 81
FG80/200A
η = 84%
FG80/160C
FG80/200B
60
68 70 72
75 79
81 76
FG80/160D
25
60 78 76
20
Ø 175
70
15
η = 82%
50
H (m)
40
30
H (m)
70
70
50
20
0
72
FG65/250C
60
25
5
72
Ø 191
25 20
70
η = 73%
80
η = 82% 81
65
FG65/250B
81
45 FG65/200B
58
FG65/250A
90
H (m)
60
FG2 65/250
Ø 169
79 75 72
40
Ø 215
Ø 160
10
Ø 206
30
Ø 148
5 0
0
30
60
90
120
150
180
210
240
20
270
P2 (kW)
A B C D
0
30
Ø 148
150
200
250
300
60
90
120
150
180
210
8
240
4 30
60
90
120
150
Q (m³/h)
180
210
240
20
0
270
Ø 175
0
Ø 206
A B
10
NPSH (m)
P2 (kW)
Ø 160
10
NPSH (m)
100
30
Ø 169
15
0
50
Ø 215
Ø 175
20
5
0
40
25
270
0
50
100
150
200
8
250
300
Ø 215
4 0
0
50
100
150
Q (m³/h)
200
250
300
169
FG2
n= 2900 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG2 80/250
FG2 100/160 40
76
FG80/250B
30
η = 77% 75 71 69
60
Ø 253
50
0
50
100
150
200
250
P2 (kW)
P2 (kW)
30
A B
20
0
50
100
150
200
250
NPSH (m)
NPSH (m)
Ø 253
4 0
50
100
150
200
Q (m³/h)
250
FG100/200A
60
60
75
79
FG100/200B
80.5
80.5 79
H (m)
H (m)
15
B C
75
79
Ø 220
71
30
180
240
300
360
Ø 210
Ø1 172-Ø2 124
100
60
120
180
240
300
360
8
Ø1 172-Ø2 156
4 0
60
120
180
240
300
Q (m³/h)
360
150
200
FG100/250A
250
65
72 75
300
η = 80% 78
70 η = 79.5%
75 71
60
30
350 Ø 220
40
Ø 256 Ø 236
0
50
100
150
200
250
300
350
P2 (kW)
Ø 201
A B C
6
Ø 236
4 A
2
10 50
100
150
200
250
300
8
NPSH (m)
4 50
100
150
200
Q (m³/h)
250
300
0
350 Ø 220
0
400
Ø 256
8
Ø 210
0
420
78
FG100/250B
10
20
420
40
50
30
420
Ø1 172-Ø2 142
50
Ø 201
50
0
80
35
P2 (kW)
120
Ø1 172-Ø2 156
90 80.5 η = 81%
40
NPSH (m)
60
100 71
45
170
0
FG2 100/250
50 FG100/200C
0
65
A
0
300
FG2 100/200
0
69
Ø1 172-Ø2 156 Ø1 172-Ø2 142 Ø1 172-Ø2 124
20
5
300
8
0
70
10
10
25
71
20
25
Ø 238
40
55
η = 75%
25
5
300
Ø 253
50
65
71
10
60
0
70
FG100/160C
15
Ø 238
40
0
65 69
FG100/160B
75
70
30
FG100/160A Ø1
35
H (m)
H (m)
80
70
Ø2
FG80/250A
90
Ø1
100
350
B
0
50
100
150
200
250
300
10
350
400
Ø 256
5 0
0
50
100
150
200
Q (m³/h)
250
300
350
400
FG4
n= 1450 1/min
PERFORMANCE RANGE 20
HS= 0 m 30
50
20
30
100 50
200
500
100
US g.p.m.
200
500
Imp. g.p.m. 80
FG4-40/250
20
FG4-50/250
FG4 - 10 0/2 50
FG4-65/250 FG4-50/200
9 8
FG4-50/160
FG4-32/160
7
FG4-65/200 FG4-80/200
FG4-65/160
FG4-80/160
H feet
-10 0/2 00
FG4-32/200
50
30
FG4
FG4-32/200H
10
FG4 -40 /20 0
Head H (metres) 4
FG4-80/250
25 20
6
60
5
3
4
5
6
200 7
8
FG4-65/125
400
9 10
-10
0/1 100
50
FG4-50/125
600
FG4
FG4-40/160
4 3
15
800 1000
30
40
Flow rate Q 4
2000
50
3000
200 m 3/h
100
PERFORMANCE DATA MODEL
FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4
pump
32/160 C 32/160 B 32/160 A 32/200 C 32/200 B 32/200 A 32/200 BH 32/200 AH 40/160 C 40/160 B 40/160 A 40/200 B 40/200 A 40/250 C 40/250 B 40/250 A 50/125 C 50/125 B 50/125 A 50/160 C 50/160 B 50/160 A 50/200 C 50/200 B 50/200 A 50/200 AR 50/250 D 50/250 C 50/250 B 50/250 A 50/250 AR
HS= 0 m
MOTOR PAIRING kW HP 0.25 0.37 0.37 0.55 0.75 1.1 0.55 0.55 0.37 0.37 0.55 0.75 1.1 1.1 1.5 2.2 0.37 0.55 0.55 0.55 0.75 1.1 1.5 2.2 2.2 3 1.1 1.5 2.2 2.2 3
10
l/min
0.33 0.5 0.5 0.75 1 1.5 0.75 0.75 0.5 0.5 0.75 1 1.5 1.5 2 3 0.5 0.75 0.75 0.75 1 1.5 2 3 3 4 1.5 2 3 3 4
PERFORMANCE
Q m³/h
H metres
3 ÷ 10.5 3 ÷ 12 3 ÷ 13.5 3 ÷ 13.5 3 ÷ 15 3 ÷ 15 3 ÷ 9 3 ÷ 9.6 3 ÷ 18 3 ÷ 18 3 ÷ 21 3 ÷ 21 3 ÷ 21 3 ÷ 21 3 ÷ 21 3 ÷ 21 9 ÷ 36 9 ÷ 36 9 ÷ 36 9 ÷ 30 9 ÷ 33 9 ÷ 33 12 ÷ 51 12 ÷ 51 12 ÷ 54 12 ÷ 54 9 ÷ 27 9 ÷ 27 9 ÷ 30 9 ÷ 30 9 ÷ 30
6 ÷ 3.5 7.5 ÷ 4 9 ÷ 6 11 ÷ 8 12.5 ÷ 9 14 ÷ 11 11 ÷ 9 13.5 ÷ 11 6.5 ÷ 3.5 8 ÷ 5 9.5 ÷ 5 11.5 ÷ 7 13.5 ÷ 10 16 ÷ 11.5 17.5 ÷ 13.5 22 ÷ 18 4 ÷ 1.5 5 ÷ 2 6 ÷ 3 7 ÷ 4 8 ÷ 5 9 ÷ 7 11 ÷ 7.5 13 ÷ 9.5 15 ÷ 11 17 ÷ 13 12.5 ÷ 8 14.5 ÷ 10.5 18 ÷ 14.5 21 ÷ 18 24 ÷ 21
MODEL
FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4 FG4
pump
MOTOR PAIRING kW HP
65/125 C 65/125 B 65/125 A 65/160 C 65/160 B 65/160 A 65/200 B 65/200 A 65/200 AR 65/250 C 65/250 B 65/250 A 80/160 D 80/160 C 80/160 B 80/160 A 80/200 B 80/200 A 80/250 B 80/250 A 100/160 C 100/160 B 100/160 A 100/200 C 100/200 B 100/200 A 100/250 B 100/250 A
0.55 0.75 1.1 1.1 1.5 2.2 2.2 2.2 3 3 4 5.5 1.5 2.2 2.2 3 4 5.5 5.5 7.5 2.2 3 3 4 5.5 5.5 7.5 9.2
0.75 1 1.5 1.5 2 3 3 3 4 4 5.5 7.5 2 3 3 4 5.5 7.5 7.5 10 3 4 4 5.5 7.5 7.5 10 12.5
PERFORMANCE
Q m³/h
H metres
18 ÷ 54 18 ÷ 60 18 ÷ 66 18 ÷ 66 18 ÷ 72 18 ÷ 72 6 ÷ 72 6 ÷ 78 6 ÷ 78 12 ÷ 70.5 12 ÷ 75 12 ÷ 78 15 ÷ 120 15 ÷ 120 15 ÷ 120 15 ÷ 120 15 ÷ 109.5 15 ÷ 117 18 ÷ 108 18 ÷ 117 30 ÷ 150 30 ÷ 165 30 ÷ 180 24 ÷ 139.5 24 ÷ 147 24 ÷ 157.5 24 ÷ 154.5 24 ÷ 172.5
4 ÷ 2.5 4.5 ÷ 3 5.5 ÷ 4.5 8 ÷ 5.5 9 ÷ 5.5 10 ÷ 7 11 ÷ 8 12.5 ÷ 9 14.3 ÷ 10.5 19 ÷ 13 21.5 ÷ 15.5 23.5 ÷ 17 6 ÷ 2.5 7.5 ÷ 3.5 8.5 ÷ 5 10 ÷ 6 14 ÷ 8.5 15.5 ÷ 10 19 ÷ 13.5 22 ÷ 15 7 ÷ 3 8 ÷ 3 8.5 ÷ 3.5 12.5 ÷ 7 14 ÷ 8 15.5 ÷ 9.5 18.5 ÷ 12 22 ÷ 14.5
171
FG4
n= 1450 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG4 32/160
FG4 32/200
10
20 FG32/160A
8
48
52
55
58
FG32/160B
7
15 FG32/200A
η = 60.5% 58 59
FG32/160C
6
H (m)
42
Ø 169
52
5
48 Ø 155 48
4
35
40
FG32/200B
H (m)
9
45
48
η = 51% 50
FG32/200C
Ø 209
10
Ø 196 Ø 184
Ø 143
3
5
2 1 0
0
5
10
0
15
0.5
Ø 155
A B C
0.2 0.1
Ø 143
0
5
10
15
Ø 169
4 2 0
5
10
Q (m³/h)
Ø 184
A B C
0
5
10
15
20
8 Ø 209
4 0
15
FG4 32/200H
0
5
10
15
Q (m³/h)
20
FG4 40/160 10
15 38
FG32/200AH
20
Ø 209
0.5
0
15
6
NPSH (m)
10
Ø 196
P2 (kW)
0.3
0
5
Ø 169
NPSH (m)
P2 (kW)
0.4
0
0
1
42 45
FG40/160A
40
9
48
50
FG32/200BH
η = 51%
10
60
62
η = 63%
FG40/160C
7
62
6
H (m)
Ø 192
H (m)
56
FG40/160B
8
Ø 205
50
5
5
60
Ø 157
Ø 169
4 Ø 148
3 2 1
0
0
1
2
3
4
5
6
7
8
9
0
10
0.6 0.4
Ø 192
AH BH
1
2
3
4
5
6
7
8
9
15
20
25
Ø 205
4 0
1
2
3
4
5
Q (m³/h)
6
7
8
9
10
Ø 169
Ø 157
A B C 0
10
NPSH (m)
NPSH (m)
172
0
8
0
10
0.5
0.2 0
5
Ø 205
P2 (kW)
P2 (kW)
0
1
0.8
0
Ø 148
5
10
15
20
8
25 Ø 169
4 0
0
5
10
Q (m³/h)
15
20
25
FG4
n= 1450 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG4 40/200
25
FG40/200A
40
42
50
FG40/250A
53 56
FG40/200B
59
20
η = 61% 59
10
56
35
40 42
45
47
η = 49% Ø 260
15
54
H (m)
30
FG40/250B FG40/250C
Ø 205
H (m)
15
FG4 40/250
Ø 188
5
Ø 233 Ø 223
10 5
0
0
5
10
15
20
1
0
25
0
5
10
15
20
25
3
Ø 205
P2 (kW)
0.5
0
NPSH (m)
A B
0
5
10
15
20
8 4 0
Ø 205
0
5
10
Q (m³/h)
15
20
FG4 50/125 54
FG50/125A
60
65
FG50/125B FG50/125C
10
15
20
25 Ø 260
4 0
5
4
68.5
10
Q (m³/h)
15
20
Ø 145
70
2
FG50/160A
8
FG50/160B
1
50
55
60
65
η = 69% 68 69
FG50/160C
25
62
5 3
Ø 126
2
Ø 161
55
4
Ø 138
65 Ø 171
6
65
71
3
9 7
η = 68.5%
H (m)
5
H (m)
5
10
6
Ø 152
1
0
5
10
15
20
25
30
35
0
40
0
5
10
15
20
25
30
1
0.6 Ø 145 Ø 138
0.4
A B C
0.2
Ø 126
35
40
Ø 171
0.8
P2 (kW)
P2 (kW)
0
8
FG4 50/160
7
0
Ø 233 Ø 223
A B C
1
0
25
Ø 260
2
0
25
NPSH (m)
P2 (kW)
Ø 188
Ø 161
0.6
Ø 152
A B C
0.4 0.2
0
5
10
15
20
25
30
35
8 Ø 145
4 0
0
5
10
15
20
Q (m³/h)
25
30
35
0
40
NPSH (m)
NPSH (m)
0
40
0
5
10
15
20
25
30
35
40
8 Ø 171
4 0
0
5
10
15
20
Q (m³/h)
25
30
35
40
173
FG4
n= 1450 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG4 50/200
FG4 50/250 25
20 50
FG50/200AR
60
64
66
FG50/200A
66
FG50/200B FG50/200C
η = 67.5% 66.5 Ø 224
10
Ø 200 Ø 185
50 52
55
η = 58% Ø 261
FG50/250B
Ø 248
FG50/250C
Ø 235
FG50/250D Ø 213
10 50
5
0
45
FG50/250A
15
Ø 215
40
FG50/250AR
20
H (m)
15
H (m)
55
Ø 204
5
0
10
20
30
40
50
0
60
3
0
5
10
15
20
25
30
3
Ø 224
Ø 261 Ø 248
0
P2 (kW)
1 0
NPSH (m)
Ø 200 Ø 185
AR A B C
10
20
30
40
50
8
Ø 224
4 0
0
10
20
30
40
Q (m³/h)
50
Ø 235
AR A B C D
1
0
5
Ø 213 Ø 204
10
15
20
25
30
8
35
Ø 261
4 0
60
FG4 65/125
2
0
60
NPSH (m)
P2 (kW)
Ø 215
2
35
0
5
10
15
20
25
Q (m³/h)
30
35
FG4 65/160
8
12
7
5
H (m)
52
FG65/125A
60
65
70
74
78
η = 79.5%
4
Ø 137
70
70
3
65
72
FG65/160B
78
FG65/125B FG65/125C
54 60
FG65/160A
10
H (m)
6
76 η = 79%
FG65/160C
8
76
Ø 125
Ø 172
Ø 116
6
2
Ø 156
1 0
0
10
20
30
40
50
60
4
70
0
10
20
30
40
50
60
70
2
2
Ø 163
80 Ø 172
A B C
NPSH (m)
0
10
20
30
40
50
60
Ø 137
4 0
10
20
30
40
Q (m³/h)
50
60
70
Ø 156
A B C
1
0
70
8
0
174
0
Ø 116
Ø 125
P2 (kW)
1
NPSH (m)
P2 (kW)
Ø 163
Ø 137
0
10
20
30
40
50
60
70
8
80 Ø 172
4 0
0
10
20
30
40
Q (m³/h)
50
60
70
80
FG4
n= 1450 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG4 65/200
25
FG65/200AR
60
65
70
75
FG65/200A
10
78
79 η = 80.1% 79
H (m)
FG65/200B
Ø 191
20
30
40
50
60
70
2
NPSH (m)
0
20
30
40
50
60
10
20
30
40
Q (m³/h)
50
FG80/160A
50
60
70
80
Ø 232
3
A B C
2 0
80
70
0
10
20
30
40
50
60
70
80
8
Ø 258
4 0
80
78
0
10
20
30
40
50
Q (m³/h)
60
Ø 175
6
Ø 169
4
70
80
30
40
50
60
70
80
90
3
20
30
40
50
60
70
80
90
8
20
30
40
50
60
70
80
90
100 110 120 130 Ø 215 Ø 206
3 A B
2
4 20
30
40
50
60
70
Q (m³/h)
80
90
0
100 110 120 130 Ø 175
10
10
1
12
0
0
4
100 110 120 130
NPSH (m)
10
Ø 148
Ø 215
5
P2 (kW)
Ø 169 Ø 160
A B C D
0
η = 78.5% 75
10
0
100 110 120 130 Ø 175
1
75
5
Ø 148
2
2
70
Ø 206
Ø 160
20
60
78
FG80/160D
10
50
FG80/200B
η = 80%
FG80/160C
0
FG80/200A
15
H (m)
8
H (m)
60
FG4 80/200 70 73
FG80/160B
P2 (kW)
50
20
10
NPSH (m)
40
4
70
60
30
Ø 204
Ø 210
0
20
Ø 258
12
0
10
Ø 248
FG4 80/160
0
0
5
4
0
10
1
8
0
Ø 258 Ø 248
Ø 210
AR A B
10
70
6
Ø 191
0
η = 71.5%
Ø 232
0
80
NPSH (m)
P2 (kW)
3
1
70
5
P2 (kW)
10
65
15
Ø 204
5
0
58
20 FG65/250C
Ø 210
0
50
FG65/250A FG65/250B
H (m)
15
FG4 65/250
0
10
20
30
40
50
60
70
80
90
100 110 120 130
12 Ø 215
8 4 0
0
10
20
30
40
50
60
70
Q (m³/h)
80
90
100 110 120 130
175
FG4
n= 1450 1/min
CHARACTERISTIC CURVES
HS= 0 m
FG4 80/250
FG4 100/160 10
9 FG100/160A 8 FG100/160B
75
20 FG80/250B
η = 76% 75
H (m)
60 70
7 FG100/160C
72
15
50
Ø 253 Ø 238
72 η = 75%
6
10
72
5 4
70
Ø1 172-Ø2 156 Ø1 172-Ø2 142 Ø1 172-Ø2 124
3 2
5
Ø1
70
Ø2
FG80/250A
60
H (m)
50
Ø1
25
1
0
0
10
20
30
40
50
60
70
80
90
0
100 110 120 130
10 Ø 253 Ø 238
4
A B
2
NPSH (m)
40
0
10
20
30
40
50
60
70
80
90
80
100
120
140
160
180
200
12 8
Ø 253
4 0
10
Ø1 172-Ø2 156
A B C
2
20
30
40
50
60
70
Q (m³/h)
80
90
0
100 110 120 130
Ø1 172-Ø2 142 Ø1 172-Ø2 124
0
20
40
60
80
100
120
140
160
180
12
200
Ø1 172-Ø2 156
8 4 0
100 110 120 130
FG4 100/200
0
20
40
60
80
100
Q (m³/h)
120
140
160
180
200
FG4 100/250
20
25 FG100/250A
15 FG100/200B
55
65
72
75
FG100/200C
78
η = 79% 78
10
55
65
70
20 FG100/250B
70 Ø 220 Ø 210
75
77 η = 78% 77 79
15
75
H (m)
FG100/200A
H (m)
60
1
NPSH (m)
P2 (kW)
6
0
20
3
P2 (kW)
8
0
0
4
75
72 Ø 256 Ø 236
10
Ø 201
5
0
5 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
2
NPSH (m)
0
P2 (kW)
Ø 210 Ø 201
A B C
4
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
8
Ø 220
4 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Q (m³/h)
176
Ø 236
6 A B
2
12
0
Ø 256
8
Ø 220
NPSH (m)
P2 (kW)
6 4
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
10
8
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
12
Ø 256
8 4 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Q (m³/h)
DIMENSIONS AND WEIGHT a
f
x
DN2
d
DN1
u
d
h2
l
SHAFT DIMENSIONS mm d u t 24 k6 8 27 32 k6 10 35
w m2 m1
DN FLANGES 32 40 50 65 80 100 125
MODEL
DN2
50
32
FG 32/200H
f
80
FG 40/160 FG 40/200
65
40
FG 40/250 FG 50/125 FG 50/160 FG 50/200
360 65
50 100
FG 50/250 FG 65/125 FG 65/160 FG 65/200
80
65
h1
h2
b
m1
132
160
50
100
160
180
55
160
180
55
132
160
50
160
180
55
180
225
65
132
160
50
160
180
55
160
200
50
180
225
65
160
180
65
160
200
65
180
225
65
FG 65/250
470
200
250
80
FG 80/160
360
180
225
65
180
250
65
200
280
80
200
280
80
200
280
80
225
280
80
FG 80/200
100
80 125
FG 80/250 FG 100/160 FG 100/200 FG 100/250
470 360
125
K mm 100 110 125 145 160 180 210
S1
b S2 110 n2 n1
HOLES N° Ø (mm) FLANGES
4 18 DN K D
8
kg
DIMENSIONS mm a
FG 32/160 FG 32/200
D mm 140 150 165 185 200 220 250
PORTS DN1
h1
t
100 140
470
95
m2
100
125
70
s1
s2
w
x
d
l
240
35
190
35 35
95
70
95
160
120
125
95
160
n2
32
100 125
n1
120
265
212
320
250
240
190
265
212
320
250
280
212
320
250
360
280
320
250
345
280
400
315
360
280
400
315
38
14
260
100
58 24
50
30 35 45 50
14
42 45 50
18 14
340
32
80
71
260
24
50
48
32
80
260
24
50
340
32
80
340
18
140
65 79 55 75 88
177
NK Multi-stage submersible pumps
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
As a result of their high efficiency and reliability they are suitable for use with clean water in domestic, civil and agricultural applications such as the distribution of water in combination with pressure sets, for the irrigation of gardens and allotments and for pressure boosting, etc.
•• Flow rate up to 120 l/min (7.2 m³/h) •• Head up to 105 m •• Maximum liquid temperature +40 °C •• Maximum sand content 50 g/m³ •• 20 m maximum immersion depth •• Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS ➠ Complete with 20 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
178
OPTIONALS AVAILABLE ON REQUEST
•• Pumps fitted with power cables of other lengths •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
110
5
0
15
5
20
10
25
15
20
30
US g.p.m.
25
Imp g.p.m.
feet 350
NK4/5
100
300
90
NK2/5 NK2/4
80
Head H (metres) 4
10
50 Hz n= 2900 1/min
250
NK4/4
70
NK4/3
60
200
NK2/3
50
NK4/2
NK2/2
40
150
NK2/1
NK4/1 100
30 20
50
10 0
0
10
20
0
30
1
40
50
2
60
3
70
80
4
90
100
5
110
6
120
l/min
0
m³/h
7
Flow rate Q 4 VERSION WITHOUT FLOAT SWITCH MODEL Single-phase NKm 2/1 NKm 2/2 NKm 2/3 NKm 2/4 NKm 2/5 NKm 4/1 NKm 4/2 NKm 4/3 NKm 4/4 NKm 4/5
Three-phase – – NK 2/3 NK 2/4 NK 2/5 – NK 4/2 NK 4/3 NK 4/4 NK 4/5
POWER kW 0.45 0.55 0.75 1.1 1.5 0.55 0.75 1.1 1.5 2.2
HP 0.6 0.75 1 1.5 2 0.75 1 1.5 2 3
Q
m³/h
0
0.6
1.2
1.8
l/min
0
10
20
35 46 58 80 87 – – – – –
33 44 55 75 83 37 48 65 72 101
36 48 60 84 90 H metres 40 50 67 75 105
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
30
40
50
60
70
80
90
100
110
120
31 41.5 51 70 78 36 46 62.5 69 98
28.5 39 47 65 73 34.5 44 60 66 94
26 35 42 59 66 32.5 41 56.5 64 90
23 30 36 51 58 30 38 52 60 86
19 25 30 42.5 48 28 35 48 57 80
15 19 23 34 38 25 32 44 53 75
21.5 28 38 48 67
18.5 24 32 43 60
14.5 19 25 38 52
10 14 18 32 44
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
“GE” VERSION WITH FLOAT SWITCH MODEL Single-phase NKm 2/1 - GE NKm 2/2 - GE NKm 2/3 - GE NKm 2/4 - GE NKm 2/5 - GE NKm 4/1 - GE NKm 4/2 - GE NKm 4/3 - GE NKm 4/4 - GE NKm 4/5 - GE Q = Flow rate H = Total manometric head
POWER kW 0.45 0.55 0.75 1.1 1.5 0.55 0.75 1.1 1.5 2.2
HP 0.6 0.75 1 1.5 2 0.75 1 1.5 2 3
Q
m³/h
0
0.6
1.2
1.8
l/min
0
10
20
30
40
50
60
70
80
90
100
110
120
35 46 58 80 87 – – – – –
33 44 55 75 83 37 48 65 72 101
31 41.5 51 70 78 36 46 62.5 69 98
28.5 39 47 65 73 34.5 44 60 66 94
26 35 42 59 66 32.5 41 56.5 64 90
23 30 36 51 58 30 38 52 60 86
19 25 30 42.5 48 28 35 48 57 80
15 19 23 34 38 25 32 44 53 75
21.5 28 38 48 67
18.5 24 32 43 60
14.5 19 25 38 52
10 14 18 32 44
36 48 60 84 90 H metres 40 50 67 75 105
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
179
NK (0.45÷1.1 kW) POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
EXTERNAL SLEEVE
Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
MOTOR SLEEVE
Stainless steel AISI 304
4
IMPELLERS AND DIFFUSERS
Noryl GFN2V
5
DIAPHRAGMS
Stainless steel AISI 304, complete with anti-wear ring
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
ST1-16 ST1-15 SIC
Ø 16 mm Ø 15 mm
8
BEARINGS
6303 2RS - C3 / 6203 ZZ - C3
9
CAPACITOR
Position Motor side Pump side
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
NKm 2/1 NKm 2/2 NKm 4/1 NKm 2/3 NKm 4/2 NKm 2/4 NKm 4/3
16 μF 500 VL
30 μF 250 VL
16 μF 500 VL
30 μF 250 VL
20 μF 500 VL
–
25 μF 500 VL
–
Materials Stationary ring
Rotational ring
Elastomer
Silicon carbide Silicon carbide
Graphite Graphite
NBR NBR
10 ELECTRIC MOTOR NKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. NK: three-phase 400 V - 50 Hz. – Insulation: F class. – Protection: IP X8. 11
POWER CABLE ➠ 20 metre long DRINCABLE® for permanent immersion in drinking water
12
11
8
1
9
3 10
6 8
12
7
FLOAT SWITCH 5 4
2
180
DIMENSIONS AND WEIGHT DN
MODEL
PORT DN
Single-phase Three-phase
DIMENSIONS mm Ø
kg
h
1~
3~
495
13.9
–
–
3
NKm 2/2
–
4
519
14.5
–
NKm 2/3
NK 2/3
5
573
16.3
15.2
NKm 2/4
NK 2/4
621
18.1
18.0
NKm 4/1
–
4
519
14.3
–
NKm 4/2
NK 4/2
5
573
16.2
15.2
NKm 4/3
NK 4/3
7
621
18.1
18.0
1¼”
135
7
h
NKm 2/1
N° STAGES
Ø
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
MODEL 110 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
240 V
415 V
NKm 2/1
4.5 A
4.5 A
9.0 A
NK 2/3
4.5 A
2.6 A
4.5 A
2.6 A
NKm 2/2
5.0 A
5.0 A
10.0 A
NK 2/4
5.2 A
3.0 A
5.2 A
3.0 A
NKm 2/3
6.0 A
6.0 A
–
NK 4/2
4.5 A
2.6 A
4.5 A
2.6 A
NKm 2/4
7.5 A
7.5 A
–
NK 4/3
5.2 A
3.0 A
5.2 A
3.0 A
NKm 4/1
5.0 A
5.0 A
10.0 A
NKm 4/2
6.0 A
6.0 A
–
NKm 4/3
7.5 A
7.5 A
–
PALLETIZATION MODEL
CONTAINER kg
kg
H (mm)
1~
3~
n° pumps
H (mm)
1~
3~
–
30
1015
434
–
60
1890
852
–
–
30
1015
452
–
60
1890
887
–
25
869
425
400
40
1307
670
626
25
869
469
467
40
1307
740
737
Three-phase
NKm 2/1
NK 2/3 NK 4/2 NK 2/4 NK 4/3
H
0 80
n° pumps
Single-phase NKm 2/2 NKm 4/1 NKm 2/3 NKm 4/2 NKm 2/4 NKm 4/3
GROUPAGE
00
12
181
NK (1.5÷2.2 kW) POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
EXTERNAL SLEEVE
Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
MOTOR SLEEVE
Stainless steel AISI 304
4
IMPELLERS AND DIFFUSERS
Noryl GFN2V
5
DIAPHRAGMS
Stainless steel AISI 304, complete with anti-wear ring
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-19 MG1-18 SIC
Ø 19 mm Ø 18 mm
8
BEARINGS
6304 2RS - C3 / 6203 ZZ - C3
9
CAPACITOR
Position Motor side Pump side
Pump
Capacitance
Single-phase
(230 V or 240 V)
NKm 2/5 NKm 4/4 NKm 4/5
Materials Stationary ring
Rotational ring
Elastomer
Silicon carbide Silicon carbide
Graphite Silicon carbide
NBR NBR
11
35 μF 450 VL 50 μF 450 VL 1
10
ELECTRIC MOTOR NKm: single-phase 230 V - 50 Hz. Windings up to 1.5 kW with built-in thermal overload protector. ➠ The NKm4/5 2.2 kW pump is equipped with an external manual reset overload protector housed in the control box. NK:
three-phase 400 V - 50 Hz.
8 6
3
– Insulation: F class. – Protection: IP X8. 11
10
8
POWER CABLE ➠ 20 metre long DRINCABLE® with removable connector for permanent immersion in drinking water
12
CONTROL BOX (for single-phase versions)
13
FLOAT SWITCH
12 7
5 9
4
2
182
13
DIMENSIONS AND WEIGHT
DN
PORT
Single-phase Three-phase
DN
NKm 2/5
NK 2/5
NKm 4/4
NK 4/4
NKm 4/5
NK 4/5
N° STAGES
DIMENSIONS mm Ø
6 1¼”
5
153
7
kg
h
1~
3~
612
26.7
23.8
582
26.0
24.4
642
30.5
28.0
h
MODEL
Ø
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
240 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
240 V
415 V
NKm 2/5
9.0 A
9.0 A
NK 2/5
6.2 A
3.6 A
6.2 A
3.6 A
NKm 4/4
9.5 A
9.5 A
NK 4/4
6.2 A
3.6 A
6.2 A
3.6 A
NKm 4/5
14.0 A
14.0 A
NK 4/5
8.5 A
4.9 A
8.5 A
4.9 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
H (mm)
1~
3~
n° pumps
NK 2/5
20
1100
551
493
40
2060 1085
969
NKm 4/4
NK 4/4
20
1100
537
505
40
2060 1058
993
NKm 4/5
NK 4/5
20
1100
627
576
40
2060 1237
1136
Three-phase
NKm 2/5
H (mm)
kg
n° pumps
Single-phase
1~
3~ H
0 80
00
12
183
DAVIS® 4” submersible pump with peripheral impellers
➠ Ready to install, stainless steel
monoblock submersible pump. Complete with: – motor with built-in capacitor and thermal overload protector – 20 m long power cable.
PERFORMANCE RANGE
•• Flow rate up to 50 l/min (3.0 m³/h) •• Head up to 75 m
APPLICATION LIMITS
•• Maximum liquid temperature +40 °C •• Maximum immersion depth of 40 m with a sufficiently long power cable
•• Vertical and horizontal installation •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
184
INSTALLATION AND USE Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their compact design and economy, they are suitable for domestic applications such as the distribution of water in combination with small pressure sets and for irrigation, etc.
PATENTS - TRADE MARKS - MODELS
•• Patent n. PCT/IB2009/051491 •• Patent Pending n. PCT/EP2009/059855
OPTIONALS AVAILABLE ON REQUEST
•• 30 m long power cable •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
80
2
4
0
50 Hz n= 2900 1/min
6
2
8
4
10
6
8
12
US g.p.m.
10
Imp g.p.m. feet 250
70
DAVIS® 200
Head H (metres) 4
60
50 150
40
100
30
20 50
10
0
0 0
5
10
15
0.5
20
25
1
30
35
1.5
40
2
45
50
2.5
3
l/min 0
0 1
m³/h
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
DAVIS®
0.75
1
Q = Flow rate H = Total manometric head
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
75
68
62
55
49
42
36
29
23
5
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
185
DAVIS® POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
DELIVERY BODY
Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1
2
PUMP BODY BACK-PLATE
Brass, reduces the risk of impeller seizure (patented)
3
IMPELLER
Brass, with peripheral radial vanes
4
MOTOR SLEEVE
Stainless steel AISI 304
5
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
6
TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
AR-14 MG1-14 SIC
Ø 14 mm Ø 14 mm
7
BEARINGS
8
CAPACITOR
Position Motor side Pump side
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Ceramic
Graphite Silicon carbide
NBR NBR
6203 ZZ - C3 / 6203 ZZ - C3
1
Capacitance
9
(230 V or 240 V)
(110 V)
31.5 μF 500 VL
70 μF 250 VL
10 2 3
ELECTRIC MOTOR Submersible PEDROLLO motor, suitable for continuous duty (with dry, rewindable stator).
6 7
DAVISm: single-phase 230 V - 50 Hz Motor with built-in capacitor. Thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8. 10
POWER CABLE
5
4
9
➠ 20 metre long PBS-P cable for AD8 permanent immersion NF C 15-100, ACS guaranteed for contact with drinking water 7
8
Patented
186
DIMENSIONS AND WEIGHT Typical installation DN
h
Safety cable anchorage point
The DAVIS® pump should be installed in boreholes of at least 4” in diameter. The pump should be lowered into the borehole, by means of the delivery pipe, to such a depth (min. 50 cm and at least one metre from the bottom) that it is completely immersed. It is good practice to secure the pump by attaching a stainless steel or nylon cable to the anchorage points present on the delivery body.
Ø
MODEL Single-phase DAVIS® - 230 V DAVIS® - 110 V
PORT
DIMENSIONS mm
DN
Ø
1”
101
h
kg
470
12.6
500
12.8
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
DAVIS®
5.7 A
5.5 A
11.5 A
PALLETIZATION MODEL
GROUPAGE / CONTAINER
Single-phase
n° pumps
H (mm)
kg 1~
DAVIS® - 230 V
60
1590
780
DAVIS® - 110 V
60
1590
792
H
0 80
00
12
187
4BLOCK 4” monoblock submersible pump
➠ Ready to install, stainless steel monoblock submersible pump. Complete with: – motor with built-in capacitor and thermal overload protector – 20 m long power cable.
PERFORMANCE RANGE
•• Flow rate up to 150 l/min (9 m³/h) •• Head up to 128 m
APPLICATION LIMITS
•• Maximum liquid temperature +35 °C •• Maximum sand content 150 g/m³ •• Maximum immersion depth of 60 m with a sufficiently long •• •• ••
power cable Vertical and horizontal installation Starts/hour: 20 at regular intervals Continuous service S1
INSTALLATION AND USE Suitable for pumping clean water from boreholes that contain sand (up to 150 g/m³). As a result of their high efficiency and reliability they are suitable for use in domestic applications such as domestic water supply as part of a pressure supply and for irrigation, etc.
PATENTS - TRADE MARKS - MODELS
•• Patent n° P CT/IB2009/051491 •• Patent Pending n° PCT/EP2009/059855, BO2009A000650
OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
188
•• 30 metre long power cable •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
130
4
8
0
12
4
16
8
50 Hz n= 2900 1/min
20
12
24
16
28
20
32 24
36 28
40
US g.p.m. Imp g.p.m.
32
feet
4BLOCK 2/20
400
120 110
350 η = 48%
100
300
Head H (metres) 4
90
4BLOCK 2/13
80 250 η = 55%
70
4BLOCK 2/10
η = 48%
200
60 50
η = 48% η = 55%
150 η = 62%
40 η = 55%
4BLOCK 4/14
30
100
η = 62%
4BLOCK 6/9
4BLOCK 4/9
20
η = 62%
4BLOCK 6/6
4BLOCK 4/7
0
50
4BLOCK 6/4
10
0 0
25 1
50 2
75
3
100
4
5
125
6
150
7
8
l/min
9
10
0
m³/h
Flow rate Q 4 MODEL
POWER
Single-phase
kW
HP
4BLOCKm 2/10
0.55
0.75
4BLOCKm 2/13
0.75
1
4BLOCKm 2/20
1.1
1.5
MODEL
POWER
Single-phase
kW
HP
4BLOCKm 4/7
0.55
0.75
4BLOCKm 4/9
0.75
1
4BLOCKm 4/14
1.1
1.5
MODEL
POWER
Single-phase
kW
HP
4BLOCKm 6/4
0.55
0.75
4BLOCKm 6/6
0.75
1
4BLOCKm 6/9
1.1
1.5
Q = Flow rate H = Total manometric head
Q
1.2
1.8
2.4
3.0
3.6
0
10
20
30
40
50
60
66
65
60
54
46
35
20
86
85
79
71
60
45
26
128
125
118
108
91
70
39
m³/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
l/min
0
20
30
40
50
60
70
80
90
100
46
44
42
40
38
35
31.5
27
23
17
60
56
54.5
52
49
45
40.5
35
29
23
92
88
85
81
76
70
63
54.5
45
35
H metres
Q
0.6
l/min
H metres
Q
0
m³/h
m³/h l/min
H metres
0
1.5
3.0
4.5
6.0
7.5
9.0
0
25
50
75
100
125
150
27
26
24
22
19
15
11
40
38
36
33
29
24
17
61
58
54
50
44
35
26
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
189
4BLOCK POS.COMPONENT
CONSTRUCTION CHARACTERISTICS
1 DELIVERY BODY AND EXTERNAL SLEEVE
Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1.
2 IMPELLERS
Lexan 141-R
3 DIFFUSERS
Noryl GFN2V
4 STAGE CASING
Stainless steel AISI 304
5 PUMP SHAFT
Stainless steel AISI 304
6 PUMP BEARINGS
Special-technopolymer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing.
1
6
15
2
8
7 DRIVE COUPLING
Stainless steel AISI 316L
3
8 CABLE COVER
Stainless steel AISI 304
4
9 MOTOR SHAFT
Stainless steel EN 10088-3 1.4104 (AISI 431 for single-phase 1.1 kW)
10 MOTOR SLEEVE
Stainless steel AISI 304 7
11 TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
STA-17
Ø 17 mm
Motor side
ST1-16 SIC
Ø 16 mm
Pump side
Position
5
Materials Stationary ring Rotational ring
Silicon carbide Silicon carbide
Elastomer
Graphite
NBR
Silicon carbide
NBR
11
12
12 BEARINGS Pump
Model
4BLOCK – 0.55÷0.75 kW 4BLOCK – 1.1 kW
6203 ZZ - C3 / 6203 ZZ - C3 3203B ZZ - C3 / 6203 ZZ - C3
9
14
13 CAPACITOR Pump
Capacitance
Single-phase
(230 V or 240 V)
4BLOCK – 0.55 kW 4BLOCK – 0.75 kW 4BLOCK – 1.1 kW
20 μF 500 VL 31.5 μF 500 VL 35 μF 500 VL
14 ELECTRIC MOTOR Submersible PEDROLLO motor, suitable for continuous duty (with dry, rewindable stator).
12
13 10
Single-phase 230 V - 50 Hz Motor with built-in capacitor. Thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8. 15 POWER CABLE ➠ 20 metre long PBS-P cable for AD8 permanent immersion NF C 15-100, ACS guaranteed for contact with drinking water
190
Patented
DIMENSIONS AND WEIGHT Typical installation Safety cable anchorage point
PORT
DIMENSIONS mm
DN
N° STAGES
Ø
kg h
1~
4BLOCKm 2/10
10
705
12.5
4BLOCKm 2/13
13
786
14.3
4BLOCKm 2/20
20
986
17.8
4BLOCKm 4/7
7
674
12.1
743
13.8
4BLOCKm 4/14
14
925
17.0
4BLOCKm 6/4
4
641
10.7
4BLOCKm 6/6
6
725
13.3
4BLOCKm 6/9
9
887
16.5
4BLOCKm 4/9
1¼”
9
100
STATIC LEVEL DYNAMIC LEVEL
h
MODEL Single-phase
Ø DN
min. 1 metre
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
4BLOCKm – 0.55 kW
5.0 A
5.0 A
4BLOCKm – 0.75 kW
6.0 A
6.0 A
4BLOCKm – 1.1 kW
8.0 A
8.0 A
PALLETIZATION MODEL
GROUPAGE / CONTAINER n° pumps
H (mm)
kg 1~
4BLOCKm 2/10
60
1260
767
4BLOCKm 2/13
40
1240
589
4BLOCKm 2/20
40
1240
729
4BLOCKm 4/7
60
1260
743
4BLOCKm 4/9
40
1240
569
Single-phase
1240
697
60
1260
659
4BLOCKm 6/6
60
1260
815
4BLOCKm 6/9
40
1240
677
0
40
80
4BLOCKm 4/14 4BLOCKm 6/4
H
00
12
191
4SR 4” submersible pumps
PERFORMANCE RANGE
•• Flow rate up to 375 l/min (22.5 m³/h) •• Head up to 405 m
APPLICATION LIMITS
•• Maximum liquid temperature +35 °C •• Maximum sand content 150 g/m³ •• 100 m immersion limit •• Installation:
•• •• ••
– vertical – horizontal, with the following limits: 4SR1 - 4SR1.5 - 4SR2 - 4SR4 up to 27 stages 4SR6 - 4SR8 - 4SR10 - 4SR12 - 4SR15 up to 17 stages Starts/hour: 20 at regular intervals Minimum flow rate for motor cooling 8 cm/s Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS ELECTRIC MOTOR – Single-phase 230 V - 50 Hz – Three-phase 400 V - 50 Hz Length of power cable: – 1.5 m for powers from 0.37 to 2.2 kW (3 kW 4SR-FK) – 2.5 m for powers from 3 to 5.5 kW (from 4 kW to 7.5 kW 4SR-FK) – 3.5 m for power from 7.5 kW 4SR-PD ➠ The 4SR-PD single-phase versions come with a capacitor included in the packaging. EN 60335-1 IEC 60335-1 CEI 61-150
192
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Suitable for use with clean water with a sand content of no more than 150 g/m³. As a result of their high efficiency and reliability, they are suitable for use in domestic, civil and industrial applications such as for the distribution of water in combination with pressure sets, for irrigation, for washing plants and for pressure boosting in fire-fighting sets, etc.
PATENTS - TRADE MARKS - MODELS
•• Patent Pending n° PCT/EP2009/059855 (cable cover)
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
50 Hz n= 2900 1/min
Head H (metres) 4
PERFORMANCE RANGE
4SR1 4SR1.5 4SR2 4SR4 4SR6 4SR8 4SR10 4SR12 4SR15
Flow rate Q 4 DESCRIPTION
4 SR 1 m / 13 - PD or FK or HYD
Borehole diameter in inches Series Flow rate in m3/h at the point of highest efficiency Single-phase motor Number of stages PD: pump with “PEDROLLO” motor FK: pump with “FRANKLIN” motor HYD: pump without motor
193
4SR1 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
300
1
2
0
1
3
50 Hz n= 2900 1/min
4
2
5
3
6
4
7
5
8 6
US g.p.m. 7
Imp g.p.m. feet
275
900
η =43%
4SR1/45
250
800
225 35
700
4SR1/35
200
32
Head H (metres) 4
600
175
4SR1/25
150
500
125
400
4SR1/18
100 300
4SR1/13
75
200
50 100
25
0
0
5
0
0.2
10 0.4
15
0.6
20
0.8
1
25
1.2
1.4
l/min
30 1.6
1.8
2
0
m³/h
Flow rate Q 4 MODEL
POWER
Q
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
l/min
0
5
10
15
20
25
30
73
67
60
51
40
26
101
93
83
71
55
36
98
77
50
136
107
70
137
90
Three-phase
kW
HP
4SR1m/13
4SR1/13
0.37
0.50
77
4SR1m/18
4SR1/18
0.55
0.75
107
4SR1m/25
4SR1/25
0.75
1
148
140
129
115
4SR1m/35
4SR1/35
1.1
1.5
206
197
182
161
4SR1m/45
4SR1/45
1.5
2
266
254
234
207
176
Single-phase
Q = Flow rate H = Total manometric head
194
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
4SR1.5 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
300
1
0
2 1
3 2
4
5
3
50 Hz n= 2900 1/min 6
4
7
5
8 6
9
10
7
11
8
9
12
US g.p.m.
10
Imp g.p.m. feet
4SR1.5/46
275
900
η =48%
250
800
225 700
4SR1.5/32
200
Head H (metres) 4
600
175
31
4SR1.5/25
28
500
150
125
400
4SR1.5/17
100 300
4SR1.5/13
75 200
4SR1.5/8
50
100
25
0
0 0
5
10
0.2
0.4
0.6
15
20
0.8
1
1.2
25
30
1.4
1.6
35
1.8
2
40 2.2
l/min
45
2.4
2.6
2.8
0
m³/h
Flow rate Q 4 MODEL
POWER
m³/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
l/min
0
5
10
15
20
25
30
35
40
45
0.50
50
48
46
44
40
36
32
26
20
14
0.75
81
78
75
71
66
59
52
43
33
23
106
102
98
93
86
78
68
56
43
30
156
151
144
136
127
115
100
83
64
45
200
193
184
175
162
147
128
106
82
58
288
277
265
250
233
211
184
153
117
83
Single-phase
Three-phase
kW
HP
4SR1.5m/8
4SR1.5/8
0.37
4SR1.5m/13
4SR1.5/13
0.55
4SR1.5m/17
4SR1.5/17
0.75
1
4SR1.5m/25
4SR1.5/25
1.1
1.5
4SR1.5m/32
4SR1.5/32
1.5
2
4SR1.5m/46
4SR1.5/46
2.2
3
Q = Flow rate H = Total manometric head
Q
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
195
4SR2 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
300
2
4
0
6
2
50 Hz n= 2900 1/min 8
4
10
6
12
8
14
10
16 US g.p.m. Imp g.p.m.
12
feet
275
900
η =54%
4SR2/39
250
800
225 45
700
200 600
Head H (metres) 4
4SR2/27
175
500
150 4SR2/20 26
125
400
100 4SR2/13
75
4SR2/10
50
4SR2/7
300
200
100
25
0
0
5
0
10
15
0.5
20
25
1
30
1.5
35
40
2
45 2.5
50
55
3
60 3.5
l/min
0
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
0.6
1.2
1.8
2.4
3.0
3.6
l/min
0
10
20
30
40
50
60
4SR2m/7
4SR2/7
0.37
0.50
48
46
44
39
33
25
14
4SR2m/10
4SR2/10
0.55
0.75
70
68
63
57
48
36
20
4SR2m/13
4SR2/13
0.75
1
4SR2m/20
4SR2/20
1.1
1.5
4SR2m/27
4SR2/27
1.5
2
180
4SR2m/39
4SR2/39
2.2
3
260
Q = Flow rate H = Total manometric head
196
H metres
90
88
82
74
62
46
26
135
130
122
111
93
71
39
173
164
150
126
96
52
250
238
216
183
138
75
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
4SR4 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
450
5
0
50 Hz n= 2900 1/min
10
15
5
20
10
25
15
US g.p.m. Imp g.p.m.
20
feet 1400
η =61%
4SR4/60
400
1300
1200
350 50
1100
4SR4/46
1000
300
Head H (metres) 4
900
250
800 35
4SR4/35
700
200 600
4SR4/26 500
150 4SR4/18
100
400
4SR4/14
300
4SR4/9
50
200
4SR4/7 100
0
0
10
0
0.5
20
30
1
1.5
40 2
50
2.5
60
3
3.5
70 4
80 4.5
90 5
5.5
0
l/min
100 6
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
l/min
0
20
30
40
50
60
70
80
90
100
4SR4m/7
4SR4/7
0.55
0.75
46
44
42
40
38
35
32
28
23
17
4SR4m/9
4SR4/9
0.75
1
60
56
55
52
49
45
40
35
29
23
4SR4m/14
4SR4/14
1.1
1.5
92
88
85
81
76
70
63
55
45
35
4SR4m/18
4SR4/18
1.5
2
120
112
109
104
98
90
81
70
58
45
4SR4m/26
4SR4/26
2.2
3
170
162
157
150
141
130
116
101
84
63
–
4SR4/35
3
4
230
220
211
202
190
175
157
137
113
85
–
4SR4/46
4
5.5
308
293
280
269
249
230
205
181
151
117
–
4SR4/60
5.5
7.5
405
385
370
350
325
300
270
235
195
155
Q = Flow rate H = Total manometric head
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
197
4SR6 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
400
5
0
10 5
15 10
50 Hz n= 2900 1/min
20
25
15
30
20
35
25
40
US g.p.m.
30
35
Imp g.p.m. feet
η =65%
4SR6/56
375
1200
350 1100
325
55
1000
300 4SR6/42
50
275
900
Head H (metres) 4
250
800
225 4SR6/31
700
200 600
175 4SR6/23
150 125
500
400
4SR6/17
100 4SR6/13
300
4SR6/9
200
75 50
4SR6/6
0
100
4SR6/4
25
0
25
0
1
50 2
75
3
4
100 5
125
6
7
l/min
150 8
9
10
0
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase 4SR6m/4 4SR6/4 4SR6m/6 4SR6/6 4SR6m/9 4SR6/9 4SR6m/13 4SR6/13 4SR6m/17 4SR6/17 – 4SR6/23 – 4SR6/31 – 4SR6/42 – 4SR6/56
POWER kW 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5
Q = Flow rate H = Total manometric head
198
HP 0.75 1 1.5 2 3 4 5.5 7.5 10
Q
m³/h
0
1.5
3.0
4.5
6.0
7.5
9.0
l/min
0
25
50
75
100
125
150
H metres
27
26
24
22
19
15
11
40
38
36
33
29
24
17 26
61
58
54
50
44
35
87
83
78
71
61
49
35
114
107
100
91
79
62
45
154
148
138
128
112
92
67
210
200
186
170
149
121
86
285
276
258
240
212
170
124
380
365
340
315
280
233
173
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
4SR8 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
300
10
50 Hz n= 2900 1/min
20
0
30
10
40
20
50
30
US g.p.m. Imp g.p.m.
40
feet
η =65% 4SR8/42
275
900
250
800
225 50
700
4SR8/31
200
Head H (metres) 4
600
175 4SR8/23
35
150
500
125
400
4SR8/17
100 4SR8/13
300
4SR8/9
200
75
4SR8/7
50
0
100
4SR8/4
25
0
20
0
1
40
60
2
3
80 4
100 5
6
120 7
140
160
8
9
180 10
l/min
200
11
12
0
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12.0
l/min
0
40
60
80
100
120
140
160
180
200
4SR8m/4
4SR8/4
0.75
1
27
26
25
24
23
22
20
17
13
10
4SR8m/7
4SR8/7
1.1
1.5
47
46
45
43
41
38
34
29
23
16
4SR8m/9
4SR8/9
1.5
2
60
58
57
55
52
48
43
37
30
21
4SR8m/13
4SR8/13
2.2
3
87
85
83
80
76
70
63
54
43
30
–
4SR8/17
3
4
–
4SR8/23
4
5.5
–
4SR8/31
5.5
–
4SR8/42
7.5
Q = Flow rate H = Total manometric head
H
metres
112
110
108
104
99
92
82
70
56
40
153
150
146
141
134
124
111
95
76
53
7.5
205
200
196
190
181
167
149
128
103
72
10
280
272
266
257
244
225
202
175
140
98
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
199
4SR10 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
240
10
0
20
50 Hz n= 2900 1/min
30
10
40
20
50
30
40
60
US g.p.m.
50
Imp g.p.m. feet
4SR10/35
η =63%
750
220 700
200
650
600
180 4SR10/26
550 44
160
500
Head H (metres) 4
40
140
450
4SR10/20 400
120
350
100
4SR10/15 300
80
250
4SR10/10 200
60 4SR10/7
40
150
4SR10/5
100
20
0
50
0
25
0
50
75
2
100
4
125
6
150 8
175
200
10
225
12
l/min
250 14
0
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
3.0
4.5
6.0
7.5
9.0
10.5
12
13.5
15.0
l/min
0
50
75
100
125
150
175
200
225
250
4SR10m/5
4SR10/5
1.1
1.5
33
31
30
28
26
24
21
18
14
10
4SR10m/7
4SR10/7
1.5
2
46
43
41
39
37
34
30
25
20
15
4SR10m/10
4SR10/10
2.2
3
66
62
59
56
53
48
42
36
28
20
–
4SR10/15
3
4
98
92
88
84
79
72
64
53
42
30
–
4SR10/20
4
5.5
130
123
118
112
106
96
85
71
56
40
–
4SR10/26
5.5
7.5
170
160
154
147
138
126
110
94
72
52
–
4SR10/35
7.5
10
230
216
208
197
184
168
148
126
100
70
Q = Flow rate H = Total manometric head
200
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
4SR12 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
200
10
0
20
30
10
20
50 Hz n= 2900 1/min
40
50
30
60
40
70
50
80 60
US g.p.m. Imp g.p.m.
70
feet
η =58%
4SR12/29
600
175 550
500
150 45
4SR12/22
450 40
Head H (metres) 4
125
400
350
4SR12/16
100
300
4SR12/12
75
250
200
4SR12/9
50
150
4SR12/6 100
4SR12/4
25
50
0
0
50
0
2
100 4
150
6
8
200 10
250
12
14
16
0
l/min
300 18
20
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
3.0
6.0
9.0
12.0
13.2
14.4
15.6
16.8
18.0
l/min
0
50
100
150
200
220
240
260
280
300
4SR12m/4
4SR12/4
1.1
1.5
25
24
22
19
16
15
14
12
11
8
4SR12m/6
4SR12/6
1.5
2
38
37
35
32
28
26
24
21
18
14
4SR12m/9
4SR12/9
2.2
3
–
4SR12/12
3
4
–
4SR12/16
4
5.5
100
97
93
86
–
4SR12/22
5.5
7.5
138
135
127
118
–
4SR12/29
7.5
10
182
176
167
155
135
Q = Flow rate H = Total manometric head
H metres
56
55
52
48
42
39
36
32
27
22
75
73
69
64
56
52
48
43
36
29
75
70
64
57
48
38
103
96
88
78
66
53
126
116
103
88
71
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
201
4SR15 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
25
50 Hz n= 2900 1/min 50
0
75
25
US g.p.m.
50
Imp g.p.m.
75
feet 500
4SR15/24
150
η =53% 450
125
400
4SR15/18 40
350
100 Head H (metres) 4
36
300
4SR15/13 250
75 4SR15/10
200
50 150
4SR15/7
4SR15/5
100
25 50
0
0
50
100
0
150
200
5
250
10
300
l/min
350
15
20
0
m³/h
Flow rate Q 4 MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
3.0
6.0
9.0
12.0
15.0
18.0
21.0
22.5
l/min
0
50
100
150
200
250
300
350
375
4SR15m/5
4SR15/5
1.5
2
31
30
28
26
23
20
15
10
7.5
4SR15m/7
4SR15/7
2.2
3
44
42
40
37
32
27
20
13
10
–
4SR15/10
3
4
–
4SR15/13
4
5.5
–
4SR15/18
5.5
–
4SR15/24
7.5
Q = Flow rate H = Total manometric head
202
62
60
57
52
46
38
30
20
15
80
77
72
68
60
50
40
25
19
7.5
112
108
102
95
85
71
55
37
27
10
150
145
138
126
112
95
75
50
36
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
4SR POS. COMPONENT 1
DELIVERY BODY
CONSTRUCTION CHARACTERISTICS Precision cast stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1
1
2
NON-RETURN VALVE
Stainless steel AISI 304
2
3
MOTOR BRACKET
Stainless steel AISI 304, in compliance with NEMA standards
8
4
IMPELLER
Lexan 141-R
5
DIFFUSER
Noryl GFN2V
6
STAGE CASING
Stainless steel AISI 304
7
PUMP SHAFT
Stainless steel AISI 304
8
PUMP BEARINGS
Special-technopolymer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing
4 5
6
11
9
DRIVE COUPLING
Stainless steel AISI 316L up to 2.2 kW; stainless steel AISI 304 for higher powers
7
10
FILTER
Stainless steel AISI 304
10
11
CABLE COVER
Stainless steel AISI 304
12
MOTOR 4"
4PD = "PEDROLLO" 4FK = "FRANKLIN"
9
3
12
203
4SR-PD
Submersible pumps with “PEDROLLO” motors DIMENSIONS AND WEIGHT Ø
MODEL Three-phase
h2
h
h1
Safety cable anchorage point
DN
MODEL Single-phase 4SR1m/13 - PD 4SR1m/18 - PD 4SR1m/25 - PD 4SR1m/35 - PD 4SR1m/45 - PD 4SR1.5m/8 - PD 4SR1.5m/13 - PD 4SR1.5m/17 - PD 4SR1.5m/25 - PD 4SR1.5m/32 - PD 4SR1.5m/46 - PD 4SR2m/7 - PD 4SR2m/10 - PD 4SR2m/13 - PD 4SR2m/20 - PD 4SR2m/27 - PD 4SR2m/39 - PD 4SR4m/7 - PD 4SR4m/9 - PD 4SR4m/14 - PD 4SR4m/18 - PD 4SR4m/26 - PD 4SR6m/4 - PD 4SR6m/6 - PD 4SR6m/9 - PD 4SR6m/13 - PD 4SR6m/17 - PD 4SR8m/4 - PD 4SR8m/7 - PD 4SR8m/9 - PD 4SR8m/13 - PD 4SR10m/5 - PD 4SR10m/7 - PD 4SR10m/10 - PD 4SR12m/4 - PD 4SR12m/6 - PD 4SR12m/9 - PD 4SR15m/5 - PD 4SR15m/7 - PD
204
PORT DN
DIMENSIONS mm Ø
h1
h2
h
1~
98
400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 281 341 431 576 695 281 371 431 576 416 518 709 365 467 658 421 525
311 331 356 386 436 311 331 356 386 436 481 311 331 356 386 436 481 331 356 386 436 481 331 356 386 436 481 356 386 436 481 386 436 481 386 436 481 436 481
711 848 1002 1242 1501 619 731 855 1032 1236 1615 601 676 756 940 1119 1410 645 714 854 1016 1237 612 697 817 1012 1176 637 757 867 1057 802 954 1190 751 903 1139 857 1006
11.0 13.1 15.8 20.1 23.6 10.1 13.1 14.3 18.5 22.4 28.7 9.9 11.1 13.2 16.8 19.5 26.0 10.7 12.5 15.7 18.0 22.3 11.4 12.2 15.1 17.6 22.3 11.6 14.6 16.3 20.9 15.5 16.9 21.8 15.0 15.8 21.8 16.7 20.8
1¼"
2"
kg
4SR1/13 - PD 4SR1/18 - PD 4SR1/25 - PD 4SR1/35 - PD 4SR1/45 - PD 4SR1.5/8 - PD 4SR1.5/13 - PD 4SR1.5/17 - PD 4SR1.5/25 - PD 4SR1.5/32 - PD 4SR1.5/46 - PD 4SR2/7 - PD 4SR2/10 - PD 4SR2/13 - PD 4SR2/20 - PD 4SR2/27 - PD 4SR2/39 - PD 4SR4/7 - PD 4SR4/9 - PD 4SR4/14 - PD 4SR4/18 - PD 4SR4/26 - PD 4SR4/35 - PD 4SR4/46 - PD 4SR4/60 - PD 4SR6/4 - PD 4SR6/6 - PD 4SR6/9 - PD 4SR6/13 - PD 4SR6/17 - PD 4SR6/23 - PD 4SR6/31 - PD 4SR6/42 - PD 4SR6/56 - PD 4SR8/4 - PD 4SR8/7 - PD 4SR8/9 - PD 4SR8/13 - PD 4SR8/17 - PD 4SR8/23 - PD 4SR8/31 - PD 4SR8/42 - PD 4SR10/5 - PD 4SR10/7 - PD 4SR10/10 - PD 4SR10/15 - PD 4SR10/20 - PD 4SR10/26 - PD 4SR10/35 - PD 4SR12/4 - PD 4SR12/6 - PD 4SR12/9 - PD 4SR12/12 - PD 4SR12/16 - PD 4SR12/22 - PD 4SR12/29 - PD 4SR15/5 - PD 4SR15/7 - PD 4SR15/10 - PD 4SR15/13 - PD 4SR15/18 - PD 4SR15/24 - PD
PORT DN
DIMENSIONS mm Ø
h1
h2
h
3~
98
400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 978 1295 1652 281 341 431 576 695 900 1164 1519 2063 281 371 431 576 695 900 1164 1519 416 518 709 1001 1256 1599 2095 365 467 658 810 1052 1358 1752 421 525 719 874 1172 1521
311 331 356 354 428 311 331 356 354 428 436 311 331 356 354 428 436 331 356 354 428 467 522 587 687 331 356 354 428 467 522 587 687 768 356 354 428 467 522 587 687 768 354 428 467 522 587 687 768 354 428 467 522 587 687 768 428 467 522 587 687 768
711 848 1002 1210 1493 619 731 855 1000 1228 1570 601 676 756 908 1111 1365 645 714 822 1008 1223 1500 1882 2339 612 697 785 1004 1162 1422 1751 2206 2831 637 725 859 1043 1217 1487 1851 2287 770 946 1176 1523 1843 2286 2863 719 895 1125 1332 1639 2045 2520 849 992 1241 1461 1859 2289
13.0 14.4 17.1 19.9 23.0 10.1 11.7 14.3 17.8 24.3 25.4 9.8 11.3 13.3 16.7 19.9 22.7 12.2 12.5 15.8 17.6 19.1 26.1 34.3 45.1 10.8 13.1 14.9 17.2 18.0 24.6 32.0 40.7 51.7 12.6 13.7 16.0 16.9 24.0 27.6 36.6 44.6 15.3 16.9 19.1 25.6 33.4 41.4 49.4 13.5 17.7 18.8 24.4 28.9 37.5 46.5 16.1 16.5 24.5 27.3 36.3 43.7
1¼"
2"
kg
4SR-FK
Submersible pumps with “FRANKLIN” motors
DIMENSIONS AND WEIGHT Ø
MODEL
DN Safety cable anchorage point
h2
h
h1
Three-phase
MODEL Single-phase 4SR1m/13 - FK 4SR1m/18 - FK 4SR1m/25 - FK 4SR1m/35 - FK 4SR1m/45 - FK 4SR1.5m/8 - FK 4SR1.5m/13 - FK 4SR1.5m/17 - FK 4SR1.5m/25 - FK 4SR1.5m/32 - FK 4SR1.5m/46 - FK 4SR2m/7 - FK 4SR2m/10 - FK 4SR2m/13 - FK 4SR2m/20 - FK 4SR2m/27 - FK 4SR2m/39 - FK 4SR4m/7 - FK 4SR4m/9 - FK 4SR4m/14 - FK 4SR4m/18 - FK 4SR4m/26 - FK 4SR6m/4 - FK 4SR6m/6 - FK 4SR6m/9 - FK 4SR6m/13 - FK 4SR6m/17 - FK 4SR8m/4 - FK 4SR8m/7 - FK 4SR8m/9 - FK 4SR8m/13 - FK 4SR10m/5 - FK 4SR10m/7 - FK 4SR10m/10 - FK 4SR12m/4 - FK 4SR12m/6 - FK 4SR12m/9 - FK 4SR15m/5 - FK 4SR15m/7 - FK
PORT DN
DIMENSIONS mm Ø
h1
h2
h
1~
98
400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 281 341 431 576 695 281 371 431 576 416 518 709 365 467 658 421 525
242 271 298 327 356 242 271 298 327 356 460 242 271 298 327 356 460 271 298 327 356 460 271 298 327 356 460 298 327 356 460 327 356 460 327 356 460 356 460
642 788 944 1183 1421 550 671 797 973 1156 1594 532 616 698 881 1039 1389 585 656 795 936 1216 552 639 758 932 1155 579 698 787 1036 743 874 1169 692 823 1118 777 985
13.0 15.4 18.6 21.8 25.4 12.6 14.9 16.9 19.9 22.8 31.7 11.6 13.5 15.3 18.0 21.1 28.1 13.1 14.7 17.1 20.5 25.7 13.8 14.6 16.6 19.4 25.8 14.1 16.1 16.6 24.5 17.0 19.3 25.4 16.6 18.8 25.2 18.5 23.8
1¼"
2"
kg
4SR1/13 - FK 4SR1/18 - FK 4SR1/25 - FK 4SR1/35 - FK 4SR1/45 - FK 4SR1.5/8 - FK 4SR1.5/13 - FK 4SR1.5/17 - FK 4SR1.5/25 - FK 4SR1.5/32 - FK 4SR1.5/46 - FK 4SR2/7 - FK 4SR2/10 - FK 4SR2/13 - FK 4SR2/20 - FK 4SR2/27 - FK 4SR2/39 - FK 4SR4/7 - FK 4SR4/9 - FK 4SR4/14 - FK 4SR4/18 - FK 4SR4/26 - FK 4SR4/35 - FK 4SR4/46 - FK 4SR4/60 - FK 4SR6/4 - FK 4SR6/6 - FK 4SR6/9 - FK 4SR6/13 - FK 4SR6/17 - FK 4SR6/23 - FK 4SR6/31 - FK 4SR6/42 - FK 4SR6/56 - FK 4SR8/4 - FK 4SR8/7 - FK 4SR8/9 - FK 4SR8/13 - FK 4SR8/17 - FK 4SR8/23 - FK 4SR8/31 - FK 4SR8/42 - FK 4SR10/5 - FK 4SR10/7 - FK 4SR10/10 - FK 4SR10/15 - FK 4SR10/20 - FK 4SR10/26 - FK 4SR10/35 - FK 4SR12/4 - FK 4SR12/6 - FK 4SR12/9 - FK 4SR12/12 - FK 4SR12/16 - FK 4SR12/22 - FK 4SR12/29 - FK 4SR15/5 - FK 4SR15/7 - FK 4SR15/10 - FK 4SR15/13 - FK 4SR15/18 - FK 4SR15/24 - FK
PORT DN
DIMENSIONS mm Ø
h1
h2
h
3~
98
400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 978 1295 1652 281 341 431 576 695 900 1164 1519 2063 281 371 431 576 695 900 1164 1519 416 518 709 1001 1256 1599 2095 365 467 658 810 1052 1358 1752 421 525 719 874 1172 1521
223 242 271 298 327 223 242 271 298 327 356 223 242 271 298 327 356 242 271 298 327 356 423 583 698 242 271 298 327 356 423 583 698 774 271 298 327 356 423 583 698 774 298 327 356 423 583 698 774 298 327 356 423 583 698 774 327 356 423 583 698 774
623 759 917 1154 1392 531 642 770 944 1127 1490 513 587 671 852 1010 1285 556 629 766 907 1112 1401 1878 2350 523 612 729 903 1051 1323 1747 2217 2837 552 669 758 932 1118 1483 1862 2293 714 845 1065 1424 1839 2297 2869 663 794 1014 1233 1635 2056 2526 748 881 1142 1457 1870 2295
13.2 14.7 17.2 20.7 24.0 11.6 13.6 16.9 18.3 21.8 27.2 10.8 11.8 13.5 16.3 20.4 24.1 11.4 13.5 15.4 17.3 20.4 26.5 39.6 49.3 12.5 12.8 14.9 18.2 20.2 24.5 36.4 44.9 55.5 12.3 14.4 15.9 18.5 22.8 33.9 41.7 48.4 15.7 17.9 20.4 26.1 36.6 45.0 53.2 15.3 17.4 20.6 26.2 34.2 42.7 48.4 17.1 19.3 23.5 33.0 41.0 47.5
1¼"
2"
kg
205
4SR-HYD DIMENSIONS AND WEIGHT (PUMP ONLY) MODEL
Ø
Pump
DN
206
h
h1
Safety cable anchorage point
4SR1/13 - HYD 4SR1/18 - HYD 4SR1/25 - HYD 4SR1/35 - HYD 4SR1/45 - HYD 4SR1.5/8 - HYD 4SR1.5/13 - HYD 4SR1.5/17 - HYD 4SR1.5/25 - HYD 4SR1.5/32 - HYD 4SR1.5/46 - HYD 4SR2/7 - HYD 4SR2/10 - HYD 4SR2/13 - HYD 4SR2/20 - HYD 4SR2/27 - HYD 4SR2/39 - HYD 4SR4/7 - HYD 4SR4/9 - HYD 4SR4/14 - HYD 4SR4/18 - HYD 4SR4/26 - HYD 4SR4/35 - HYD 4SR4/46 - HYD 4SR4/60 - HYD 4SR6/4 - HYD 4SR6/6 - HYD 4SR6/9 - HYD 4SR6/13 - HYD 4SR6/17 - HYD 4SR6/23 - HYD 4SR6/31 - HYD 4SR6/42 - HYD 4SR6/56 - HYD 4SR8/4 - HYD 4SR8/7 - HYD 4SR8/9 - HYD 4SR8/13 - HYD 4SR8/17 - HYD 4SR8/23 - HYD 4SR8/31 - HYD 4SR8/42 - HYD 4SR10/5 - HYD 4SR10/7 - HYD 4SR10/10 - HYD 4SR10/15 - HYD 4SR10/20 - HYD 4SR10/26 - HYD 4SR10/35 - HYD 4SR12/4 - HYD 4SR12/6 - HYD 4SR12/9 - HYD 4SR12/12 - HYD 4SR12/16 - HYD 4SR12/22 - HYD 4SR12/29 - HYD 4SR15/5 - HYD 4SR15/7 - HYD 4SR15/10 - HYD 4SR15/13 - HYD 4SR15/18 - HYD 4SR15/24 - HYD
PORT DN
DIMENSIONS mm Ø
h1
h
98
400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 978 1295 1652 281 341 431 576 695 900 1164 1519 2063 281 371 431 576 695 900 1164 1519 416 518 709 1001 1256 1599 2095 365 467 658 810 1052 1358 1752 421 525 719 874 1172 1521
403 520 649 859 1068 311 403 502 649 803 1137 293 348 403 557 686 932 317 361 471 583 759 981 1298 1655 284 344 434 579 698 903 1167 1522 2066 284 374 434 579 698 903 1167 1522 419 521 712 1004 1259 1602 2098 368 470 661 813 1055 1361 1755 424 528 722 877 1175 1524
1¼"
2"
kg 4.7 5.9 7.4 9.4 11.4 3.8 4.8 5.7 7.3 9.2 13.2 3.6 4.2 4.8 7.0 7.7 10.5 3.8 4.3 5.4 6.6 8.3 10.7 15.0 19.4 3.7 4.0 4.8 6.1 7.1 9.3 11.8 15.0 22.0 3.5 4.2 4.7 6.1 7.2 9.3 11.8 14.9 4.4 5.3 6.9 9.5 12.0 15.7 19.7 4.0 4.8 6.6 8.1 9.6 12.8 15.9 4.5 5.3 7.0 8.4 11.1 14.0
4SR INSTALLATION EXAMPLE
5 9
11
12
7
8
8
5
4
4
6
6
DYNAMIC LEVEL
7
STATIC LEVEL
STATIC LEVEL
3
DYNAMIC LEVEL
2
2
1
1
min. 1 metre
min. 1 metre
COMPONENTS 1) Submersible pump 2) Power cable clamps 3) Level probes; prevent dry running 4) Pump anchorage 5) Pressure gauge 6) Non-return valve 7) Gate valve; for flow rate regulation
10
8) Power cable 9) Control box 10) Pressure vessel 11) Pressure switch 12) Electro valve/electro-compressor
➠The 4SR series pumps should be installed in boreholes of at least 4� (100 mm) in diameter. The pump should be lowered into the borehole, by means of the delivery pipe, to such a depth (min. 50 cm and at least one metre from the bottom) that it is completely immersed during operation when the level of water in the borehole may reduce. It is good practice to secure the pump by attaching a stainless steel cable to the anchorage points present on the delivery body.
207
6SR 6” submersible pumps
PERFORMANCE RANGE
•• Flow rate up to 1000 l/min (60 m³/h) •• Head up to 390 m
APPLICATION LIMITS
•• Maximum liquid temperature +35 °C •• Maximum sand content 100 g/m³ •• 100 m immersion limit •• Installation:
•• •• ••
– vertical – horizontal, with the following limits: up to 12 stages or 11 kW Starts/hour: 20 at regular intervals Minimum flow rate for motor cooling 16 cm/s (0.5 m/s for 30 kW) Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS ELECTRIC MOTOR – Three-phase 400 V - 50 Hz
INSTALLATION AND USE Suitable for use with clean water with a sand content of no more than 100 g/m³. As a result of their high efficiency and reliability, they are suitable for use in civil, agricultural and industrial applications such as for the distribution of water in combination with pressure sets, for irrigation and for pressure boosting in fire-fighting sets, etc.
4 m long power cable
OPTIONALS AVAILABLE ON REQUEST
EN 60034-1 IEC 60034-1 CEI 2-3
•• Other voltages or 60 Hz frequency
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
208
•• 6SR-HYD pumps with double cable cover suitable for adual voltage 400/690 V (star/delta) motors from 11 kW to 30 kW
GUARANTEE 1 year subject to terms and conditions
50 Hz n= 2900 1/min
Head H (metres) 4
PERFORMANCE RANGE
6SR12 6SR18 6SR27 6SR36 6SR44
Flow rate Q 4
DESCRIPTION
6 SR 12 / 8 - PD or HYD
Borehole diameter in inches Series Flow rate in m3/h at the point of highest efficiency Number of stages PD: pump with “PEDROLLO” motor HYD: pump without motor
209
6SR12 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
450
10
0
20 10
30 20
50 Hz n= 2900 1/min
40
50
30
60
40
70
50
80 60
90
US g.p.m.
70
80
Imp g.p.m. feet
η =67% 1400
400
1300
6SR12/28
1200
6SR12/25
350
1100
52
1000
300
47
6SR12/21
Head H (metres) 4
900
6SR12/18
250
800
700
6SR12/15
200 600
6SR12/11
150
500
400
6SR12/8
100
300
200
50 100
0
0 0
50 2
100 4
6
150 8
200 10
250
12
14
300 16
l/min
350
18
20
22
0
m³/h
Flow rate Q 4 MODEL
POWER
m³/h
0
3.0
6.0
9.0
12.0
15.0
18.0
19.8
l/min
0
50
100
150
200
250
300
330
HP
6SR12/8
4
5.5
111
106
100
91
80
66
47
32
6SR12/11
5.5
7.5
153
146
138
125
110
91
65
44
6SR12/15
7.5
10
6SR12/18
9.2
12.5
H metres
208
199
189
171
150
124
88
60
250
239
225
205
180
149
106
72
6SR12/21
11
15
292
279
263
239
210
174
124
84
6SR12/25
13
17.5
349
331
313
285
250
206
147
100
6SR12/28
15
20
390
371
350
319
280
231
165
112
Q = Flow rate H = Total manometric head
210
Q
kW
Three-phase
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
6SR18 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
400
20
40
0
50 Hz n= 2900 1/min 60
20
80
40
100
60
80
120
US g.p.m.
100
Imp g.p.m. feet
350
1200
η =71%
6SR18/26
1100
100
6SR18/22
300
58
900
Head H (metres) 4
250
50
6SR18/18
800
700
6SR18/15
200
150
6SR18/13
600
6SR18/11
500
6SR18/9
400
100
300
6SR18/6
6SR18/4
200
50 100
0
0
50
100
0
150
5
200
250
10
300
350
15
400
20
0
l/min
450 25
m³/h
Flow rate Q 4 MODEL
POWER
Q
m³/h
0
3
6
9
12
15
18
21
24
27
l/min
0
50
100
150
200
250
300
350
400
450
53
51
49
46
42
37
30
22
79
77
74
69
63
55
45
32
kW
HP
6SR18/4
4
5.5
54
53.8
6SR18/6
5.5
7.5
81
80.5
Three-phase
6SR18/9
7.5
10
122
121
119
116
111
103
94
83
68
48
6SR18/11
9.2
12.5
149
148
145.5
141
135
126
115
101
83
59
H metres
6SR18/13
11
15
176
175
172
167
160
149
136
120
98
70
6SR18/15
13
17.5
203
202
199
193
185
172
157
138
113
80
6SR18/18
15
20
244
242
238
231
221
206
188
165
135
96
6SR18/22
18.5
25
298
296
291
282
270
252
230
202
165
118
6SR18/26
22
30
352
350
344
334
320
298
272
239
195
139
Q = Flow rate H = Total manometric head
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
211
6SR27 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
400
20
40
0
60
20
50 Hz n= 2900 1/min
80
40
100
60
120
80
140
100
160 120
US g.p.m. 140
Imp g.p.m. feet
η =68%
6SR27/27
1200
350 1100
100
56
300 6SR27/20
900
Head H (metres) 4
250
800
41
6SR27/17
700
200
6SR27/14 600
6SR27/12 500
150 6SR27/10
400
6SR27/8
100
6SR27/7
300
6SR27/5 200
6SR27/4
50 100
0
0 0
100
200
5
10
300
400
15
20
500 25
l/min
600
30
35
40
0
m³/h
Flow rate Q 4 MODEL Three-phase 6SR27/4 6SR27/5 6SR27/7 6SR27/8 6SR27/10 6SR27/12 6SR27/14 6SR27/17 6SR27/20 6SR27/27
POWER kW 4 5.5 7.5 9.2 11 13 15 18.5 22 30
HP 5.5 7.5 10 12.5 15 17.5 20 25 30 40
Q = Flow rate H = Total manometric head
212
Q
m³/h
0
6
12
18
24
30
36
l/min
0
100
200
300
400
500
600
54 68 95 109 136 164 191 231 272 367
53 66 92 106 132 159 185 224 264 356
49 62 87 99 124 149 174 211 248 335
45 57 80 91 114 137 160 194 228 308
40 50 70 80 100 120 140 170 200 270
30 37 52 59 74 89 104 126 148 205
18 22 31 35 44 53 62 75 88 119
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
6SR36 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
300
20
0
40
60
20
80
40
50 Hz n= 2900 1/min
100
60
120
80
140
100
160
120
180 140
200 160
220 US g.p.m. Imp g.p.m.
180
feet
η =73%
275
900
6SR36/23
250
800
225
6SR36/19
59
700
Head H (metres) 4
200 600
6SR36/15
175
6SR36/13
150
500
6SR36/11
125
400
6SR36/10
100
31
6SR36/8
75
300
6SR36/6 200
6SR36/4
50
100
25
0
0 0
100
200
5
10
300 15
400 20
500
25
600
30
35
700 40
45
0
l/min
800 50
m³/h
Flow rate Q 4 MODEL Three-phase 6SR36/4 6SR36/6 6SR36/8 6SR36/10 6SR36/11 6SR36/13 6SR36/15 6SR36/19 6SR36/23
POWER kW 4 5.5 7.5 9.2 11 13 15 18.5 22
HP 5.5 7.5 10 12.5 15 17.5 20 25 30
Q = Flow rate H = Total manometric head
Q
m³/h
0
6
12
18
24
30
36
42
48
l/min
0
100
200
300
400
500
600
700
800
47 70 94 117 129 152 176 222 269
45 67 89 111 123 145 167 212 256
42 63 84 105 115 136 157 199 241
38 57 76 95 105 124 143 181 219
34 51 68 85 93 110 127 161 195
29 44 59 74 81 96 110 140 169
25 37 50 62 68 81 93 118 143
19 29 39 48 53 63 72 92 111
14 20 27 34 37 44 51 65 78
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
213
6SR44 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
275
50
0
50 Hz n= 2900 1/min
100
150
50
200
100
250
150
US g.p.m. Imp g.p.m.
200
feet
η =73%
250
6SR44/21
800
225 700
200
57
6SR44/16
600
Head H (metres) 4
175
6SR44/13
150
500 40
6SR44/11
125
400
6SR44/9
100
6SR44/8
75
300
6SR44/6 200
6SR44/5
50
6SR44/4 6SR44/3 100
25
0
0 0
MODEL Three-phase 6SR44/3 6SR44/4 6SR44/5 6SR44/6 6SR44/8 6SR44/9 6SR44/11 6SR44/13 6SR44/16 6SR44/21
100 5
200 10
15
POWER kW 4 5.5 7.5 9.2 11 13 15 18.5 22 30
HP 5.5 7.5 10 12.5 15 17.5 20 25 30 40
Q = Flow rate H = Total manometric head
214
300
Q
400 20
500
25
600
30
700
35
40
Flow rate Q 4
800 45
900 50
1000
55
60
l/min
0
m³/h
m³/h
0
12
18
24
30
36
42
48
54
60
l/min
0
200
300
400
500
600
700
800
900
1000
35 47 58 70 93 105 128 151 186 244
33 44 54 65 87 98 120 141 174 228
31 42 52 62 83 93 114 135 166 218
30 40 49 59 79 89 109 128 158 207
28 37 46 56 74 83 102 120 148 194
26 34 43 51 68 77 94 111 136 179
23 31 38 46 61 69 84 99 122 160
20 27 33 40 53 60 73 86 106 139
17 23 28 34 45 51 62 73 90 118
13 18 22 26 35 39 48 57 70 92
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
6SR INSTALLATION EXAMPLE 9
12
8
11
5
4 6
10
➠The 6SR series pumps should be installed in boreholes of at least 6� (150 mm) in diameter. The pump should be lowered into the borehole, by means of the delivery pipe, to such a depth (min. 50 cm and at least one metre from the bottom) that it is completely immersed during operation when the level of water in the borehole may reduce. It is good practice to secure the pump by attaching a stainless steel cable to the anchorage points present on the delivery body.
7
STATIC LEVEL DYNAMIC LEVEL
3
2
1
COMPONENTS 1) Submersible pump 2) Power cable clamps 3) Level probes 4) Pump anchorage 5) Pressure gauge 6) Non-return valve 7) Gate valve; for flow rate regulation 8) Power cable 9) Control box 10) Pressure vessel 11) Pressure switch 12) Electro valve/electro-compressor
min. 1 metre
Vertical installation
Cooling jacket Minimum height 0.5 metres
Cooling jacket
It is necessary to fit the pump with a cooling jacket in installations in storage tanks, rivers and lakes in order to prevent the motor from overheating.
215
6SR12-18-27 POS. COMPONENT 1
DELIVERY BODY
(Radial impellers)
CONSTRUCTION CHARACTERISTICS Nickel-plated cast iron complete with threaded delivery port in compliance with ISO 228/1
11 1
2
NON-RETURN VALVE
Stainless steel AISI 304
3
MOTOR BRACKET
Nickel-plated cast iron, in compliance with NEMA standards
8
2
4
IMPELLERS
Special-rubber coated Noryl GFN2V
4
5
DIFFUSERS
Noryl GFN2V
5
6
DIFFUSOR CASING
Stainless steel AISI 304
6
7
PUMP SHAFT
Stainless steel AISI 304
8
PUMP BEARINGS
Special elastomer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing
9
DRIVE COUPLING
7
Stainless steel AISI 420
10 FILTER
Stainless steel AISI 304
11 CABLE COVER
Stainless steel AISI 304
12 MOTOR 6"
6PD = "PEDROLLO"
10 9 3
12
216
6SR36-44 POS. COMPONENT 1
DELIVERY BODY
(Semi-axial impellers)
CONSTRUCTION CHARACTERISTICS Stainless steel AISI 304 complete with threaded delivery port in compliance with ISO 228/1
1
2
NON-RETURN VALVE
Stainless steel AISI 304
2
3
MOTOR BRACKET
Nickel-plated cast iron, in compliance with NEMA standards
8
4
IMPELLERS
Special-rubber coated Noryl GFN2V
5
DIFFUSERS
Noryl GFN2V
5
11
4
6
DIFFUSOR CASING
Stainless steel AISI 304
7
PUMP SHAFT
Stainless steel AISI 304
8
PUMP BEARINGS
Special-technopolymer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing
9
DRIVE COUPLING
10 FILTER
Stainless steel AISI 420
6
7
10
Stainless steel AISI 304 3
11 CABLE COVER
Stainless steel AISI 304
12 MOTOR 6"
6PD = "PEDROLLO"
9
12
217
6SR-PD DIMENSIONS AND WEIGHT Ø
MODEL
DN
Three-phase
Safety cable anchorage point
PORT DN
DIMENSIONS mm Ø
h
h1
6 SR 12/8 - PD
h2
h
3~
633
1352
53.8
849
667
1516
60.9
6 SR 12/15 - PD
1068
698
1766
66.8
6 SR 12/18 - PD
1198
731
1929
73.0
6 SR 12/21 - PD
1328
826
2154
83.9
6 SR 12/25 - PD
1502
894
2396
96.0
6 SR 12/28 - PD
1632
894
2526
98.1
6 SR 18/4 - PD
545
633
1178
49.6
6 SR 18/6 - PD
632
667
1299
53.6
6 SR 18/9 - PD
762
698
1460
60.3
6 SR 18/11 - PD
849
731
1580
67.0
6 SR 18/13 - PD
981
826
1807
76.9
6 SR 18/15 - PD
1068
894
1962
84.6
6 SR 18/18 - PD
1198
894
2092
87.6
6 SR 18/22 - PD
1371
959
2330
99.7
6 SR 18/26 - PD
1545
1116
2661
125.7
6 SR 27/4 - PD
583
633
1216
47.9
6 SR 27/5 - PD
636
667
1303
53.5
6 SR 27/7 - PD
742
698
1440
58.8
6 SR 27/8 - PD
795
731
1526
63.0
6 SR 27/10 - PD
901
826
1727
74.1
1051
894
1945
83.6
1157
894
2051
85.9
6 SR 27/12 - PD
h2
h1 719
6 SR 12/11 - PD
6 SR 27/14 - PD
218
kg
3"
149.5
6 SR 27/17 - PD
1316
959
2275
97.5
6 SR 27/20 - PD
1474
1116
2590
123.0
6 SR 27/27 - PD
1845
1243
3088
135.8
6 SR 36/4 - PD
823
633
1456
55.4
6 SR 36/6 - PD
1049
667
1716
64.0
6 SR 36/8 - PD
1275
698
1973
71.0
6 SR 36/10 - PD
1501
731
2232
76.2
6 SR 36/11 - PD
1613
826
2439
90.0
6 SR 36/13 - PD
1839
894
2733
102.0
6 SR 36/15 - PD
2065
894
2959
107.0
6 SR 36/19 - PD
2517
959
3476
121.0
6 SR 36/23 - PD
2969
1116
4085
154.0
6 SR 44/3 - PD
710
633
1343
54.0
6 SR 44/4 - PD
823
667
1490
57.5
6 SR 44/5 - PD
936
698
1634
63.1
6 SR 44/6 - PD
1049
731
1780
70.0
6 SR 44/8 - PD
1275
826
2101
82.2
6 SR 44/9 - PD
1388
894
2282
92.0
6 SR 44/11 - PD
1613
894
2507
97.0
6 SR 44/13 - PD
1839
959
2798
110.0
6 SR 44/16 - PD
2178
1116
3294
141.0
6 SR 44/21 - PD
2743
1243
3986
154.3
6SR-HYD DIMENSIONS AND WEIGHT Ø
MODEL
DN
Pump
Safety cable anchorage point
PORT DN
DIMENSIONS mm Ø
h
6 SR 12/8 - HYD
h
kg
719
19.8
6 SR 12/11 - HYD
849
24.9
6 SR 12/15 - HYD
1068
27.8
6 SR 12/18 - HYD
1198
31.0
6 SR 12/21 - HYD
1328
33.9
6 SR 12/25 - HYD
1502
39.0
6 SR 12/28 - HYD
1632
41.1
6 SR 18/4 - HYD
545
15.6
6 SR 18/6 - HYD
632
17.6
6 SR 18/9 - HYD
762
21.3
6 SR 18/11 - HYD
849
25.0
6 SR 18/13 - HYD
981
26.9
6 SR 18/15 - HYD
1068
27.6
6 SR 18/18 - HYD
1198
30.6
6 SR 18/22 - HYD
1371
34.7
6 SR 18/26 - HYD
1545
38.7
6 SR 27/4 - HYD
583
13.9
6 SR 27/5 - HYD
636
17.5
6 SR 27/7 - HYD
742
19.8
6 SR 27/8 - HYD
795
21.0
6 SR 27/10 - HYD
901
24.1
6 SR 27/12 - HYD
1051
26.6
1157
28.9
6 SR 27/17 - HYD
1316
32.5
6 SR 27/20 - HYD
1474
36.0
6 SR 27/27 - HYD
1845
44.8
6 SR 36/4 - HYD
823
21.4
6 SR 36/6 - HYD
1049
28.0
6 SR 36/8 - HYD
1275
32.0
6 SR 36/10 - HYD
1501
34.2
6 SR 36/11 - HYD
1613
40.0
6 SR 36/13 - HYD
1839
45.0
6 SR 27/14 - HYD
3"
149.5
6 SR 36/15 - HYD
2065
50.0
6 SR 36/19 - HYD
2517
56.0
6 SR 36/23 - HYD
2969
67.0
6 SR 44/3 - HYD
710
20.0
6 SR 44/4 - HYD
823
21.5
6 SR 44/5 - HYD
936
24.1
6 SR 44/6 - HYD
1049
28.0
6 SR 44/8 - HYD
1275
32.2
6 SR 44/9 - HYD
1388
35.0
6 SR 44/11 - HYD
1613
40.0
6 SR 44/13 - HYD
1839
45.0
6 SR 44/16 - HYD
2178
54.0
6 SR 44/21 - HYD
2743
63.3
219
4PD PEDROLLO 4” submersible motors
PERFORMANCE RANGE
CERTIFICATIONS
APPLICATION LIMITS
COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
•• Powers from 0.37 to 7.5 kW •• Maximum liquid temperature +35 °C •• 100 m immersion limit •• Starts/hour: 20 at regular intervals •• Minimum flow rate for motor cooling 8 cm/s •• Continuous service S1
OPTIONALS AVAILABLE ON REQUEST
ELECTRIC MOTOR
GUARANTEE
•• 2 pole electric motor, 50 Hz (n ~ 2900 1/min) •• Voltage:
– single-phase 230 V up to 2.2 kW – three-phase 400 V
•• Insulation: F class Protection: IP 68
CONSTRUCTION AND SAFETY STANDARDS Rewindable submersible oil filled motor (oil type vegetable). Flange coupling dimensions in compliance with NEMA standards. Complete with power cable of the following length: – 1.5 m for powers from 0.37 to 2.2 kW – 2.5 m for powers from 3 to 5.5 kW – 3.5 m for power from 7.5 kW. ➠ Single-phase versions come with a capacitor included in the packaging. EN 60034-1 IEC 60034-1 CEI 2-3
220
•• Other voltages or 60 Hz frequency
1 year subject to terms and conditions
PERFORMANCE DATA Single-phase versions Rated power
Axial load
Revs
h
Weight
Starting current Rated current
Power factor
cos ϕ
μF
mm
kg
2800
3.3
0.86
20
311
6.5
P2
Capacitor (VL=450V)
230 V / 50 Hz
kW
HP
4PDm / 0.50
0.37
0.50
4PDm / 0.75
0.55
0.75
2810
3.5
0.89
25
331
7.2
4PDm / 1
0.75
1
2825
3.2
0.91
35
356
8.5
4PDm / 1.5
1.1
1.5
2840
3.2
0.93
40
386
10.5
4PDm / 2
1.5
2
2845
3.3
0.93
60
436
11.7
4PDm / 3
2.2
3
2820
3.1
0.94
75
481
15.0
N
h
2000
1/min
38
MODEL
Three-phase versions MODEL
Rated power
Axial load
Revs
N
1/min
P2 400 V / 50 Hz
kW
HP
Starting current Rated current
Power factor
h
Weight
cos ϕ
mm
kg
4PD / 0.50
0.37
0.50
2855
3.3
0.52
311
6.5
4PD / 0.75
0.55
0.75
2835
4
0.63
331
7.2
4PD / 1
0.75
1
4PD / 1.5
1.1
1.5
2000
2825
3.8
0.71
356
8.5
2780
3.5
0.79
354
10.4
4PD / 2
1.5
2
2825
4.4
0.76
428
11.1
4PD / 3
2.2
3
2810
6.5
0.73
436
11.7
4PD / 4
3
4
2810
4.7
0.78
522
15.6
4PD / 5.5
4
5.5
2820
5.1
0.77
587
18.8
4PD / 7.5
5.5
7.5
2845
5.4
0.82
687
25.4
4PD / 10
7.5
10
2835
5.3
0.3
768
29.2
2500 4500
Ø 96
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
Three-phase
230 V
400 V
240 V
415 V
4PDm / 0.50
3.6 A
4PD / 0.50
3.1 A
1.8 A
3.0 A
1.7 A
4PDm / 0.75
4.7 A
4PD / 0.75
3.5 A
2.0 A
3.3 A
1.9 A
4PDm / 1
5.9 A
4PD / 1
4.3 A
2.5 A
4.2 A
2.4 A
4PDm / 1.5
8.3 A
4PD / 1.5
5.0 A
2.9 A
5.2 A
3.0 A
4PDm / 2
10.7 A
4PD / 2
7.1 A
4.1 A
7.4 A
4.3 A
4PDm / 3
15.2 A
4PD / 3
10.6 A
6.1 A
10.2 A
5.9 A
4PD / 4
13.0 A
7.5 A
13.7 A
7.9 A
4PD / 5.5
17.0 A
9.8 A
17.8 A
10.3 A
4PD / 7.5
22.8 A
13.2 A
23.5 A
13.6 A
4PD / 10
29.2 A
16.9 A
29.9 A
17.3 A
221
4FK FRANKLIN ELECTRIC 4” submersible motors
PERFORMANCE RANGE
•• Powers from 0.37 to 7.5 kW
APPLICATION LIMITS
•• Maximum liquid temperature +35 °C •• 100 m immersion limit •• Starts/hour: 20 at regular intervals •• Minimum flow rate for motor cooling 8 cm/s •• Continuous service S1
ELECTRIC MOTOR
•• 2 pole electric motor, 50 Hz (n ~ 2900 1/min) •• Voltage:
•• ••
– single-phase 230 V fino a 2.2 kW – three-phase 400 V Insulation: B class Protection: IP 68
CONSTRUCTION AND SAFETY STANDARDS Resin encapsulated windings. Flange coupling dimensions in compliance with NEMA standards. Complete with power cable of the following length: – 1.5 m for powers from 0.37 to 3 kW – 2.5 m for powers from 4 to 7.5 kW ➠ Capacitor not included for single-phase versions. EN 60034-1 IEC 60034-1 CEI 2-3
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
222
PERFORMANCE DATA Single-phase versions Rated power
Axial load
Revs
kW
HP
4FKm / 0.50
0.37
0.50
4FKm / 0.75
0.55
0.75
4FKm / 1
0.75
1
4FKm / 1.5
1.1
1.5
4FKm / 2
1.5
2
4FKm / 3
2.2
3
N
cos ϕ
μF
mm
kg
2860
3.3
0.93
16
242
8.3
2855
3.7
0.94
20
271
9.6
2855
3.7
0.98
30
298
10.8
1/min
1500
3000
Capacitor (VL=450V)
2855
3.7
0.94
40
327
12.1
2825
3.3
0.95
50
356
13.5
2810
3.4
0.99
70
460
18
h
4000
Weight
Power factor
P2 230 V / 50 Hz
h
Starting current Rated current
38
MODEL
Three-phase versions MODEL
Rated power
Axial load
Revs
N
1/min
P2 400 V / 50 Hz
kW
4FK / 0.50
0.37
0.5
4FK / 0.75
0.55
0.75
HP
1500
Starting current Rated current
Power factor
h
Weight
cos ϕ
mm
kg
2865
4.3
0.7
223
7.3
2855
4
0.75
242
8.3
4FK / 1
0.75
1
2870
4.4
0.75
271
9.6
4FK / 1.5
1.1
1.5
2840
4.8
0.76
298
10.8
4FK / 2
1.5
2
4FK / 3
2.2
3
4FK / 4
3
4
4FK / 5.5
4
5.5
4FK / 7.5
5.5
7.5
4FK / 10
7.5
10
3000 4000
6500
2855
4.8
0.76
327
12.1
2840
4.9
0.75
356
13.5
2850
5.3
0.75
423
16
2855
5.8
0.78
583
24.1
2850
6.0
0.79
698
29.4
2820
5.5
0.79
774
33
Ø 95.5
ABSORPTION MODEL Single-phase
VOLTAGE (single-phase) 230 V
MODEL Three-phase
VOLTAGE (three-phase) 230 V
400 V
4FKm / 0.50
3.4 A
4FK / 0.50
1.9 A
1.1 A
4FKm / 0.75
4.3 A
4FK / 0.75
2.8 A
1.6 A
4FKm / 1
5.7 A
4FK / 1
3.6 A
2.1 A
4FKm / 1.5
8.6 A
4FK / 1.5
5.2 A
3.0 A
4FKm / 2
10.6 A
4FK / 2
6.9 A
4.0 A
4FKm / 3
16.0 A
4FK / 3
10.2 A
5.9 A
4FK / 4
13.5 A
7.8 A
4FK / 5.5
17.3 A
10.0 A
4FK / 7.5
23.7 A
13.7 A
4FK / 10
31.8 A
18.4 A
223
6PD 6” submersible motors
PERFORMANCE RANGE
•• Powers from 4 to 30 kW
CONSTRUCTION AND SAFETY STANDARDS Rewindable submersible oil filled motor (oil type vegetable). Flange coupling dimensions in compliance with NEMA standards.
APPLICATION LIMITS
Complete with 4 m long power cable.
•• Maximum liquid temperature +35 °C •• 100 m immersion limit •• Suitable for vertical and horizontal installations with operating
EN 60034-1 IEC 60034-1 CEI 2-3
•• Starts/hour: 20 at regular intervals •• Minimum flow rate for motor cooling 16 cm/s (0.5 m/s for 30 kW) •• Continuous service S1
CERTIFICATIONS
limits as described for the 6SR submersible pump
ELECTRIC MOTOR
•• 2 pole electric motor, 50 Hz (n ~ 2900 1/min) •• Three-phase voltage 400 V •• Insulation: F class •• Protection: IP 68
COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
OPTIONALS AVAILABLE ON REQUEST
•• Dual voltage 400/690 V (star/delta) motors from 11 kW to 30 kW •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
224
Rated power
Three-phase 400 V / 50 Hz
Axial load
Revs
N
1/min
P2
Starting current Rated current
Efficiency
Power factor
Rated torque
η
cos ϕ
Nm
Starting torque Rated torque
h
Weight
mm
kg
kW
HP
6PD / 5.5
4
5.5
2840
4.6
79%
0.77
13.5
1.8
633
34
6PD / 7.5
5.5
7.5
2850
5.1
80%
0.74
18.4
2
667
36
6PD / 10
7.5
10
2835
5.2
81%
0.80
25.3
2
698
39
6PD / 12.5
9.2
12.5
2850
5.4
82%
0.78
30.8
2.3
731
42
6PD / 15
11
15
2895
5.5
82%
0.77
36.3
2.2
826
50
6PD / 20
15
20
2875
5.4
83%
0.78
49.8
2.1
894
57
6PD / 25
18.5
25
2870
6
84%
0.78
61.6
2.4
959
65
6PD / 30
22
30
2890
5.9
85%
0.70
72.7
2.5
1116
87
6PD / 40
30
40
2850
6.2
85%
0.82
100.6
2.7
1243
91
10000
20000
h
MODEL
73
PERFORMANCE DATA
Ø 140
ABSORPTION MODEL Three-phase
VOLTAGE (three-phase) 400 V
415 V
6PD / 5.5
9.5 A
9.6 A
6PD / 7.5
13.5 A
13.2 A
6PD / 10
16.8 A
17.1 A
6PD / 12.5
20.9 A
21.5 A
6PD / 15
25.3 A
26.6 A
6PD / 20
33.4 A
34.7 A
6PD / 25
40.7 A
42.1 A
6PD / 30
53.3 A
57.6 A
6PD / 40
61.9 A
62.2 A
225
TOP MULTI® Submersible multi-impeller pumps
PERFORMANCE RANGE
•• Flow rate up to 120 l/min (7.2 m³/h) •• Head up to 42 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their high efficiency and reliability they are suitable for use in applications such as domestic water supply from reservoirs, tanks or relatively deep wells, for drawing rain water from cisterns to water gardens or for use in irrigation systems, etc.
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 1.3 mm •• Suction down to 22 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS Complete with: – 10 m long power cable – float switch EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
226
PATENTS - TRADE MARKS - MODELS
•• Registered model TOP MULTI® n° 1334477 •• Registered Community Design n° 000885587
OPTIONALS AVAILABLE ON REQUEST
•• Pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
45
5
10
0
50 Hz n= 2900 1/min
15
5
20
10
25
15
20
30
US g.p.m.
25
Imp g.p.m. feet 140
TOP MULTI 2
40
120
35 TOP MULTI 3 100
Head H (metres) 4
30 25
80
20 60
15 40
10 20
5 0
0
10
0
20
30
1
40
50
2
60
3
70
80
4
90
100
5
110
6
120
l/min
0
m³/h
7
Flow rate Q 4
POWER
MODEL Single-phase
kW
HP
TOP MULTI 2
0.55
0.75
TOP MULTI 3
0.55
0.75
Q = Flow rate H = Total manometric head
Q
m³/h
0
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
l/min
0
10
20
30
40
50
60
70
80
90
100
110
120
42
40
38
34
30
24
18
11.5
5
33
32
31
29.5
28
25.5
23
20.5
18
15
12
8
4
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
227
TOP MULTI POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
DELIVERY BODY
Glass fibre reinforced technopolymer, complete with threaded delivery port in compliance with ISO 228/1
2
PUMP BODY AND SUCTION FILTER
Glass fibre reinforced technopolymer
3
MOTOR SLEEVE
Stainless steel AISI 304
4
IMPELLERS
Noryl GFN2V
5
DIFFUSERS
Noryl GFN2V complete with anti-wear rings
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
STA-13R STA-12R SIC
Ø 13 mm Ø 12 mm
8
BEARINGS
6202 ZZ - C3 / 6201 ZZ
9
CAPACITOR
Position Motor side Pump side
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Ceramic
Graphite Silicon carbide
NBR NBR
14
Capacitance
10
(230 V or 240 V)
(110 V)
12.5 μF 450 VL
30 μF 250 VL
ELECTRIC MOTOR TOP MULTI: single-phase 230 V - 50 Hz with built-in overload protector. – Insulation: F class. – Protection: IP X8.
11
11 13
POWER CABLE
1
8
➠ 10 metre long “H07 RN-F” cable with Schuko plug
6
12
FLOAT SWITCH
10
13
HOSE CONNECTOR WITH UNION
3
Ø 35 mm hose connection 14
PIPE COUPLING
9
12
8 7
Threaded 1¼” in compliance with ISO 228/1, complete with clapet valve 2
4
5
228
DIMENSIONS AND WEIGHT Typical installation
e d
h
p (minimum)
DN
(minimum) a
MODEL
PORT
DIMENSIONS mm
N° STAGES
DN
Single-phase TOP MULTI 2
1¼"
TOP MULTI 3
3
a
h
d
e
p
178
380
22
variable
500
kg 500
9.4
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP MULTI 2
3.4 A
3.3 A
6.8 A
TOP MULTI 3
3.6 A
3.5 A
7.2 A
PALLETIZATION MODEL Single-phase
GROUPAGE n° H (mm) pumps
CONTAINER kg
n° pumps
H (mm)
kg
TOP MULTI 2
60
1370
582
80
1780
770
TOP MULTI 3
60
1370
582
80
1780
770
H
0 80
00
12
229
TOP Submersible DRAINAGE pumps ➠ for clear water
PERFORMANCE RANGE
•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 14.5 m
APPLICATION LIMITS
•• Immersion depth: •• •• •• ••
– 3 m for TOP 1-2-3 – 5 m for TOP 4-5 (with a sufficiently long power cable) Maximum liquid temperature +40 °C (Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 10 mm Suction level: – 14 mm above ground level for TOP 1-2-3 – 30 mm above ground level for TOP 4-5 Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable for TOP 1-2-3 – 10 m long power cable for TOP 4-5 – float switch EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE The TOP series is suitable for use with clear water that does not contain abrasive particles. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0011
OPTIONALS AVAILABLE ON REQUEST
•• “TOP 2-3 LA” pumps intended for use with aggressive liquids •• Special mechanical seal •• TOP 1-2-3 pumps with 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
230
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
TOP5
TOP4
Head H (metres) 4
TOP3
TOP2
TOP1
Flow rate Q 4
MODEL
POWER
m³/h
0
1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12 13.2 14.4 15.6 16.8 18.0 19.2 20.4 21.6 22.8 24
l/min
0
20
0.33
7
6
5.5 4.5
4
0.50
9
8
7.5 6.5
6
Single-phase
kW
HP
TOP 1
0.25
TOP 2
0.37
TOP 3
0.55
0.75
TOP 4
0.75
1
TOP 5
0.92
1.25
Q = Flow rate H = Total manometric head
Q
H metres 10.5 10
40
9
60
8.8
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 3
2.5 1.5
5.5 4.5
4
1 3
2.5 1.8
1
8
7.5 6.5
6
5.5 4.8
4
3.5 2.5
2
12.6 12 11.5 10.7 10
9.3 8.7
8
7.3 6.7
6
5.3 4.7
4
14.5 14 13.5 12.7 12.1 11.5 10.8 10.2 9.6 8.9 8.3 7.7
3.3 2.7
2
7.1 6.4 5.8 5.2 4.5 3.9 3.3 2.6
2
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
231
TOP 1-2-3 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Technopolymer
2
SUCTION FILTER
Technopolymer
3
SUCTION PLATE
Stainless steel AISI 304
4
DIFFUSER
Technopolymer
5
IMPELLER
Noryl GFN2V
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Pump
Seal
Shaft
Model
Model
Diameter
TOP 1-2-3 TOP 2-3 LA
AR-12R AR-12R LA
Ø 12 mm Ø 12 mm
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Ceramic
Graphite Graphite
NBR NBR
14
13
14
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
TOP 1 TOP 2 TOP 3
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL
16 μF 250 VL 16 μF 250 VL 16 μF 250 VL
1
ELECTRIC MOTOR
12
– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
11
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
15
15
HOSE CONNECTOR WITH UNION Ø 25 mm hose connection for TOP 1 Ø 35 mm for TOP 2-3
6 13 11 7 10
8 4
232
5
9
2
3
DIMENSIONS AND WEIGHT Typical installation
d
e
p (minimum)
h
h1
DN
(minimum)
a
MODEL Single-phase
PORT
DIMENSIONS mm
DN
a
TOP 1 TOP 2
1¼”
152
TOP 3
h
h1
257
237
287
267
d
e
kg
p
4.5 14
variable
350
350
5.2 6.6
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP 1
1.4 A
1.3 A
3.0 A
TOP 2
2.0 A
2.0 A
5.3 A
TOP 3
3.2 A
3.2 A
7.9 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
TOP 1
96
TOP 2 TOP 3
Single-phase
CONTAINER kg
n° pumps
H (mm)
kg
1260
444
168
2100
765
96
1260
515
168
2100
888
96
1360
653
144
1970
971
H
0 80
00
12
233
TOP 4-5 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Technopolymer
2
SUCTION FILTER
Technopolymer
3
SUCTION PLATE
Stainless steel AISI 304
4
DIFFUSER
Technopolymer
5
IMPELLER
Ryton
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
10
LIP SEAL
Ø 16 x Ø 24 x H 5 mm
11
BEARINGS
6203 ZZ / 6203 ZZ
12
CAPACITOR Pump
13
15
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
TOP 4 TOP 5
16 μF 450 VL 20 μF 450 VL
30 μF 250 VL 30 μF 250 VL
– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8 14
1 12
11
HOSE CONNECTOR WITH UNION Hose connection Ø 41 mm
16
16
HANDLE ASSEMBLY (resin sealed) Complete with: – 10 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
15
14
ELECTRIC MOTOR
PIPE COUPLING In technopolymer with 1½" thread and clapet valve
6 13 11
7 10
8 4
234
5
9
2
3
DIMENSIONS AND WEIGHT Typical installation
d
a
MODEL Single-phase TOP 4 TOP 5
e
p (minimum)
h
h1
DN
PORT
(minimum)
DIMENSIONS mm
DN
a
h
h1
d
e
p
1½”
204
334
310
30
variable
450
kg 450
10.1 11.1
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP 4
4.8 A
4.8 A
9.6 A
TOP 5
6.5 A
6.5 A
13.0 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
TOP 4
54
TOP 5
54
Single-phase
CONTAINER kg
n° pumps
H (mm)
1295
563
90
2065
928
1295
617
90
2065
1016
kg H
0 80
00
12
235
TOP-GM Submersible DRAINAGE pumps ➠ for clear water
Version with vertical magnetic float switch
PERFORMANCE RANGE
•• Flow rate up to 260 l/min (15.6 m3/h) •• Head up to 10.5 m
APPLICATION LIMITS
•• 3 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 10 mm •• Suction down to 14 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable – vertical magnetic float switch EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
236
INSTALLATION AND USE The TOP-GM series is suitable for use with clear water that does not contain abrasive particles and comes complete with a vertical float switch meaning that the pumps can be used in particularly small spaces. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0011
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Pumps with a 10 m long power cable ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
TOP3-GM
Head H (metres) 4
TOP2-GM
TOP1-GM
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
TOP 1-GM
0.25
0.33
TOP 2-GM
0.37
0.50
TOP 3-GM
0.55
0.75
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12
13.2
14.4
15.6
l/min
0
20
40
60
80
100
120
140
160
180
200
220
240
260
7
6
5.5
4.5
4
3
2.5
1.8
1
9
8
7.5
6.5
6
5.5
4.5
4
3
2.5
1.8
1
10.5
10
9
8.8
8
7.5
6.5
6
5.5
4.8
4
3.5
2.5
2
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
237
TOP-GM POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Technopolymer
2
SUCTION FILTER
Technopolymer
3
SUCTION PLATE
Stainless steel AISI 304
4
DIFFUSER
Technopolymer
5
IMPELLER
Noryl GFN2V
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR
13
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
TOP 1-GM TOP 2-GM TOP 3-GM
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL
16 μF 250 VL 16 μF 250 VL 16 μF 250 VL
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
15
15
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
14
14
HOSE CONNECTOR WITH UNION Ø 25 mm hose connection for TOP 1 Ø 35 mm for TOP 2-3
1 12 11
6 13 11 7 10
8 4
238
5
9
2
3
DIMENSIONS AND WEIGHT Typical installation
p (minimum) a (minimum)
b
MODEL Single-phase
PORT
DIMENSIONS mm
DN
a
b
1¼”
152
200
TOP 1-GM TOP 2-GM
ee
g
d
h1
h
DN
TOP 3-GM
h
h1
257
237
287
267
d 14
e
g
140
35
170
40
kg
p
4.6 350
220
5.3 6.7
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP 1-GM
1.4 A
1.3 A
3.0 A
TOP 2-GM
2.0 A
2.0 A
5.3 A
TOP 3-GM
3.2 A
3.2 A
7.9 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER
n° pumps
H (mm)
kg
n° pumps
H (mm)
kg
TOP 1-GM
96
1260
459
168
2100
790
TOP 2-GM
96
1260
526
168
2100
910
TOP 3-GM
96
1500
660
144
2180
982
Single-phase
H
0 80
00
12
239
TOP-FLOOR Submersible DRAINAGE pumps ➠ for clear water
PERFORMANCE RANGE
•• Flow rate up to 160 l/min (9.6 m3/h) •• Head up to 9 m
APPLICATION LIMITS
•• 3 m maximum immersion depth
INSTALLATION AND USE The TOP-FLOOR series is suitable for use with clear water that does not contain abrasive particles. As a result of their ability to drain water to a level of 2 millimetres above ground level, they are suitable for use in domestic emergencies where a small area must be drained to the lowest level possible.
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• •• ••
(Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 2 mm Suction down to 2 mm above ground level Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0011
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with float switch •• Special mechanical seal •• Pumps with a 10 m long power cable
Complete with 5 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
240
••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
9
10
50 Hz n= 2900 1/min
20
0
30
10
US g.p.m.
40
20
Imp g.p.m.
30
feet
TOP2-FLOOR
8
25
Head H (metres) 4
7 TOP1-FLOOR
6
20
5 15
4 10
3 2
5
1 0
0 0
20
40
1
60
2
3
80 4
100 5
120
6
7
140 8
160
l/min
9
10
0
m³/h
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
TOP1-FLOOR
0.25
0.33
TOP2-FLOOR
0.37
0.50
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
l/min
0
20
40
60
80
100
120
140
160
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
241
TOP-FLOOR POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Technopolymer
2
SUCTION FILTER
Technopolymer
3
SUCTION PLATE
Stainless steel AISI 304
4
DIFFUSER
Technopolymer
5
IMPELLER
Noryl GFN2V
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR Pump
13
14
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
TOP1-FLOOR TOP2-FLOOR
10 μF 450 VL 10 μF 450 VL
16 μF 250 VL 16 μF 250 VL
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
14
1 12
11
HANDLE ASSEMBLY (resin sealed) Complete with 5 metre long “H07 RN-F” power cable with Schuko plug
15
15
6
HOSE CONNECTOR WITH UNION
13
Ø 25 mm hose connection for TOP1 - FLOOR Ø 35 mm for TOP2 - FLOOR
11 7 10
8 4
242
5
9
2
3
DIMENSIONS AND WEIGHT
Typical installation
Draining down to 2 mm
h
h1
DN
a
MODEL
PORT
TOP1-FLOOR TOP2 -FLOOR
DIMENSIONS mm
DN
a
h
h1
Minimum drying level
1¼”
152
257
237
2 mm
Single-phase
kg 4.3 5.0
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP1-FLOOR
1.4 A
1.3 A
3.0 A
TOP2-FLOOR
2.0 A
2.0 A
5.3 A
PALLETIZATION MODEL
GROUPAGE
Single-phase
n° pumps
H (mm)
TOP1-FLOOR
96
TOP2 -FLOOR
96
CONTAINER kg
n° pumps
H (mm)
kg
1260
430
168
2100
739
1260
500
168
2100
862
H
0
80
00
12
243
TOP-VORTEX Submersible pump ➠ for dirty water
PERFORMANCE RANGE
•• Flow rate up to 180 l/min (10.8 m3/h) •• Head up to 7 m
APPLICATION LIMITS
•• 3 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• •• ••
(Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 20 mm Suction down to 25 mm above ground level Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable – float switch EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
244
INSTALLATION AND USE The TOP-VORTEX pump is suitable for use with dirty water that is not chemically aggressive towards the materials from which the pump is made. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as clearing dirty water, emptying tanks, discharging domestic waste water, and for emptying collection traps containing suspended solids up to a maximum of Ø 20 mm.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0011
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
Head H (metres) 4
TOP–VORTEX
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
TOP-VORTEX
0.37
0.50
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
l/min
0
20
40
60
80
100
120
140
160
180
7
6.5
6
5.4
4.8
4.2
3.5
3
2.5
1.5
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
245
TOP-VORTEX POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Technopolymer
2
SUCTION FILTER
Technopolymer
3
SUCTION PLATE
Technopolymer
4
DIFFUSER
Technopolymer
5
IMPELLER
Technopolymer VORTEX type
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR
14
Capacitance
13
(230 V or 240 V)
(110 V)
10 μF 450 VL
16 μF 250 VL
15
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
1
12 11
14
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
15
6 13
HOSE CONNECTOR WITH UNION
11
Hose connection Ø 35 mm
7 10
8
4
5
246
9
2
3
DIMENSIONS AND WEIGHT
Typical installation
a
MODEL
e d
p (minimum)
h
h1
DN
PORT
(minimum)
DIMENSIONS mm
Single-phase
DN
a
h
h1
d
e
p
TOP-VORTEX
1¼”
152
288
268
25
variable
350
kg 350
5.1
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP-VORTEX
2.0 A
2.0 A
5.3 A
PALLETIZATION MODEL
GROUPAGE
Single-phase
n° pumps
H (mm)
TOP-VORTEX
96
1360
CONTAINER kg
n° pumps
H (mm)
kg
508
144
1970
753
H
0 80
00
12
247
TOP-VORTEX/GM Submersible pump ➠ for dirty water
Version with vertical magnetic float switch
PERFORMANCE RANGE
•• Flow rate up to 180 l/min (10.8 m3/h) •• Head up to 7 m
APPLICATION LIMITS
•• 3 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 20 mm •• Suction down to 25 mm above ground level •• Continuous service S1
INSTALLATION AND USE The TOP-VORTEX/GM pump is suitable for use with dirty water and comes complete with a vertical float switch meaning that the pump can be used in particularly small spaces. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as clearing dirty water, emptying tanks, discharging domestic waste water, and for emptying small collection traps containing suspended solids up to a maximum of Ø 20 mm.
PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS
•• Registered Community Design n° 342159-0011
Complete with: – 5 m long power cable – vertical magnetic float switch
OPTIONALS AVAILABLE ON REQUEST
EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
248
•• Special mechanical seal •• Pumps with a 10 m long power cable ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
Head H (metres) 4
TOP-VORTEX/GM
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
TOP-VORTEX/GM
0.37
0.50
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
l/min
0
20
40
60
80
100
120
140
160
180
7
6.5
6
5.4
4.8
4.2
3.5
3
2.5
1.5
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
249
TOP-VORTEX/GM POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Technopolymer
2
SUCTION FILTER
Technopolymer
3
SUCTION PLATE
Technopolymer
4
DIFFUSER
Technopolymer
5
IMPELLER
Technopolymer VORTEX type
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR
14 15
Capacitance
13
(230 V or 240 V)
(110 V)
10 μF 450 VL
16 μF 250 VL
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
14
15
1 12
11
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
13
HOSE CONNECTOR WITH UNION
11
Hose connection Ø 35 mm
6
7 10
4 8
5
250
9
2
3
DIMENSIONS AND WEIGHT
Typical installation
e
d
g
p (minimum)
h1
h
DN
a b
MODEL
(minimum)
PORT
DIMENSIONS mm
Single-phase
DN
a
b
h
h1
d
e
g
p
TOP-VORTEX/GM
1¼”
152
200
288
268
25
170
40
350
kg 220
5.2
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
TOP-VORTEX/GM
2.0 A
2.0 A
5.3 A
PALLETIZATION MODEL Single-phase TOP-VORTEX/GM
GROUPAGE n° pumps
H (mm)
96
1360
CONTAINER kg
n° pumps
H (mm)
kg
520
144
1970
771
H
0 80
00
12
251
RX Submersible DRAINAGE pumps ➠ for clear water
PERFORMANCE RANGE
•• Flow rate up to 300 l/min (18 m3/h) •• Head up to 20 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +50 °C •• •• ••
(Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 10 mm Suction level: – 14 mm above ground level for RX 1-2-3 – 25 mm above ground level for RX 4-5 Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable for RX1-2-3 – 10 m long power cable for RX 4-5 – float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
252
INSTALLATION AND USE The RX series pumps are suitable for use with clear water that does not contain abrasive particles. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in fixed installations and applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0013 (RX 1-2-3)
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• RX 1-2-3 pumps with a 10 m long power cable. •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
22
10
0
20
30
10
50 Hz n= 2900 1/min 40
20
50
30
60
40
US g.p.m.
70
50
Imp g.p.m.
60
feet
20
RX5 60
18 16
50
Head H (metres) 4
RX4
14 40
12
RX3
10
RX2
30
8 RX1
6
20
4 10
2 0
0
20
0
40 2
60
80
100
4
MODEL
kW
140
6
POWER
Single-phase Three-phase
120
HP
Q
8
160
180
200
10
220
12
Flow rate Q 4
240
260
14
280 16
300 l/min 18
m³/h
m³/h
0
1.2
3.6
6.0
8.4
9.6
12.0
13.2
15.6
18.0
l/min
0
20
60
100
140
160
200
220
260
300
2.5
2
RXm 1
–
0.25
0.33
7.5
6.5
5
3.5
2
1
RXm 2
–
0.37
0.50
10
9.5
8
6.5
5
4.5
RXm 3
–
0.55
0.75
12
11.5
9.5
8
6.5
5.5
3.5
3
RXm 4
RX 4
0.75
1
16
15
13
11.5
9.5
8.5
6.5
5.5
4
RXm 5
RX 5
1.1
1.5
20
19.5
17.5
15.5
13.5
12.5
10
9
7
Q = Flow rate H = Total manometric head
0
H metres
5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
253
RX 1-2-3 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Stainless steel AISI 304
5
MOTOR CASING
Stainless steel AISI 304
6
MOTOR CASING PLATE
Stainless steel AISI 304
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
9
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
10
BEARINGS
6201 ZZ / 6201 ZZ
11
CAPACITOR Pump
12
13
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
RXm 1 RXm 2 RXm 3
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL
16 μF 250 VL 16 μF 250 VL 16 μF 250 VL
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
13
1 11
10
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
5 12 10 6 9
7 4
254
8
2
3
DIMENSIONS AND WEIGHT
Typical installation
d
e
p (minimum)
h
h1
DN
(minimum)
a
MODEL Single-phase
PORT
DIMENSIONS mm
DN
a
1¼”
147
RXm 1 RXm 2 RXm 3
h
h1
255
247
285
277
d
e
p
14
variable
350
kg 4.7 350
5.8 7.4
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
RXm 1
1.4 A
1.3 A
3.0 A
RXm 2
2.0 A
2.0 A
5.3 A
RXm 3
3.6 A
3.6 A
7.5 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
RXm 1
96
RXm 2 RXm 3
Single-phase
CONTAINER kg
n° pumps
H (mm)
kg
1320
467
162
2131
776
96
1320
573
162
2131
955
96
1360
727
144
1970
1083
H
0 80
00
12
255
RX 4-5 POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Stainless steel AISI 304
5
MOTOR CASING
Stainless steel AISI 304
6
MOTOR CASING PLATE
Stainless steel AISI 304
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE MECHANICAL SEAL SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14D SIC
Ø 14 mm
9
BEARINGS
10
CAPACITOR Pump
11
Materials Stationary ring
Rotational ring
Silicon carbide Silicon carbide
13
NBR
6203 ZZ / 6203 ZZ 12
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
RXm 4 RXm 5
20 μF 450 VL 25 μF 450 VL
30 μF 250 VL –
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
12
Elastomer
POWER CABLE
1 10
9 7
5
10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
11
FLOAT SWITCH
9
13
(only for single-phase versions) 6
8
4
256
2
3
DIMENSIONS AND WEIGHT
Typical installation
d
e
p (minimum)
h
h1
DN
a
MODEL Single-phase
PORT
Three-phase
RXm 4
RX 4
RXm 5
RX 5
(minimum)
DIMENSIONS mm
kg
DN
a
h
h1
d
e
p
1½"
220
367
336
25
variable
500
1~ 500
3~
12.7
11.9
13.7
12.7
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
RXm 4
5.4 A
5.4 A
11.0 A
RX 4
3.6 A
2.1 A
3.6 A
2.1 A
–
RX 5
6.0 A
3.5 A
6.0 A
3.5 A
7.5 A
RXm 5
7.5 A
415 V
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
kg
3~
n° pumps
H (mm)
1~
3~
Single-phase
Three-phase
RXm 4
RX 4
45
1388
589
553
60
1804
779
731
RXm 5
RX 5
45
1388
634
589
60
1804
839
779
H
0
80
00
12
257
RX-GM Submersible DRAINAGE pumps ➠ for clear water
Version with vertical magnetic float switch
PERFORMANCE RANGE
•• Flow rate up to 220 l/min (13.2 m3/h) •• Head up to 12 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 10 mm •• Suction down to 14 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable – vertical magnetic float switch EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
258
INSTALLATION AND USE The RX-GM series is suitable for use with clear water that does not contain abrasive particles and comes complete with a vertical float switch meaning that the pumps can be used in particularly small spaces. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in fixed installations and applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0013
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Pumps with a 10 m long power cable. ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
13
10
0
20
50 Hz n= 2900 1/min 30
10
40
20
50
30
US g.p.m.
40
Imp g.p.m. feet 40
12
RX3-GM
11
35
10
RX2-GM 30
Head H (metres) 4
9 8
25
7
RX1-GM 20
6 5
15
4 10
3 2
5
1 0
0 0
20 1
40
60
2
3
80 4
100 5
6
120 7
140 8
160 9
180 10
11
200 12
220 13
l/min 0
0 1
m³/h
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
RXm 1-GM
0.25
0.33
RXm 2-GM
0.37
0.50
RXm 3-GM
0.55
0.75
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.2
3.6
6.0
8.4
9.6
12.0
13.2
l/min
0
20
60
100
140
160
200
220
7.5
6.5
5
3.5
2
1
10
9.5
8
6.5
5
4.5
2.5
2
12
11.5
9.5
8
6.5
5.5
3.5
3
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
259
RX-GM POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Stainless steel AISI 304
5
MOTOR CASING
Stainless steel AISI 304
6
MOTOR CASING PLATE
Stainless steel AISI 304
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
9
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
10
BEARINGS
6201 ZZ / 6201 ZZ
11
CAPACITOR
12
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
RXm 1-GM RXm 2-GM RXm 3-GM
10 μF 450 VL 10 μF 450 VL 14 μF 450 VL
16 μF 250 VL 16 μF 250 VL 16 μF 250 VL
13
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8
13
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
1 11
10
5 12 10 6 9
7 4
260
8
2
3
DIMENSIONS AND WEIGHT
Typical installation
a
MODEL Single-phase
(minimum)
PORT
DIMENSIONS mm
DN
a
1¼”
147
RXm 1-GM RXm 2-GM
e
g
d
h1
h
p (minimum)
DN
RXm 3-GM
h
h1
270
247
300
277
d 14
e
g
145
40
175
45
kg
p
4.8 350
240
5.9 7.5
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
RXm 1-GM
1.4 A
1.3 A
3.0 A
RXm 2-GM
2.0 A
2.0 A
5.3 A
RXm 3-GM
3.6 A
3.6 A
7.5 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
RXm 1-GM
60
RXm 2-GM RXm 3-GM
Single-phase
CONTAINER kg
n° pumps
H (mm)
kg
1409
312
90
2054
456
60
1409
378
90
2054
555
60
1489
474
75
1844
587
H
0 80
00
12
261
RX 2-3-4-5 "VORTEX" Submersible pumps ➠ for dirty water
PERFORMANCE RANGE
•• Flow rate up to 380 l/min (22.8 m3/h) •• Head up to 13 m
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
APPLICATION LIMITS
•• 10 m maximum immersion depth •• •• •• ••
(with a sufficiently long power cable) Maximum liquid temperature +50 °C (Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Solids passage: – up to Ø 20 mm for RX 2/20, RX 3/20 – up to Ø 40 mm for RX 4/40, RX 5/40 Suction level: – 25 mm above ground level for RX 2/20, RX 3/20 – 50 mm above ground level for RX 4/40, RX 5/40 Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable for RX 2/20, RX 3/20 – 10 m long power cable for RX 4/40, RX 5/40 – float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150
262
EN 60034-1 IEC 60034-1 CEI 2-3
INSTALLATION AND USE The RX-VORTEX series pumps are suitable for use with dirty water. The design solutions that have been adopted, such as the complete cooling of the motor, guarantee the reliability of the pump. They are suitable for use in domestic applications such as for discharging dirty water containing suspended solids.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0013
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal •• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
15
10
0
20
30
10
40
20
50 Hz n= 2900 1/min 50
30
60
40
70
80
50
US g.p.m.
90
60
70
80
Imp g.p.m. feet
14
50
13 RX5/40 40
12
Head H (metres) 4
11
35
10 RX4/40 30
9 8
RX3/20 25
7 RX2/20 20
6 5
15
4 10
3 2
5
1 0
0
20
0
40
60
2
80 4
100
120
6
140
160
8
180
10
200
220
12
240
260
14
280
300
16
320
18
340 20
360
380 l/min
0
m³/h
22
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase
kW
HP
Q
m³/h
0
1.2
2.4
3.6
4.8
6
7.2
8.4
9.6
10.8
13.2
16.8
20.4
22.8
l/min
0
20
40
60
80
100
120
140
160
180
220
280
340
380
3
2
RXm 2/20
–
0.37
0.50
7
6.5
6
5.4
4.8
4.3
3.7
3.1
2.5
2
RXm 3/20
–
0.55
0.75
9
8
7.5
6.5
6
5.5
4.7
4.2
3.5
3
RXm 4/40
RX 4/40
0.75
1
10
9.5
8.7
8.5
7.7
7
6.5
6
5.5
4.7
3.7
2
RXm 5/40
RX 5/40
1.1
1.5
13
12.5
12
11.5
10.7
10
9.5
9
8.3
7.7
6.5
5
Q = Flow rate H = Total manometric head
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
263
RX 2-3 "VORTEX" POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
DIFFUSER
Technopolymer
5
IMPELLER
Stainless steel AISI 304 VORTEX type
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R SIC
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR Pump
13
14
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
RXm 2/20 RXm 3/20
10 μF 450 VL 14 μF 450 VL
16 μF 250 VL 16 μF 250 VL
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class. – Protection: IP X8.
14
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
1 12
11 6 7 13 11 10
9 4 8
5
264
2
3
DIMENSIONS AND WEIGHT
Typical installation
d
e
p (minimum)
h
h1
DN
a
MODEL Single-phase RXm 2/20 RXm 3/20
(minimum)
PORT
DIMENSIONS mm
DN
a
1¼”
147
h
h1
290
278
320
308
d
e
p
25
variable
350
kg 350
6.1 7.85
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
RXm 2/20
2.6 A
2.6 A
6.5 A
RXm 3/20
3.2 A
3.2 A
7.5 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
RXm 2/20
96
RXm 3/20
60
Single-phase
CONTAINER kg
n° pumps
H (mm)
kg
1500
607
144
2180
902
1310
488
100
2090
802
H
0
80
00
12
265
RX 4-5 "VORTEX" POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Stainless steel AISI 304 VORTEX type
5
MOTOR CASING
Stainless steel AISI 304
6
MOTOR CASING PLATE
Stainless steel AISI 304
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE MECHANICAL SEAL SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14D SIC
Ø 14 mm
9
BEARINGS
10
CAPACITOR
11
Materials Stationary ring
Rotational ring
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
RXm 4/40 RXm 5/40
20 μF 450 VL 25 μF 450 VL
30 μF 250 VL –
ELECTRIC MOTOR
12
10 1 7 9
5
POWER CABLE 10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
13
NBR
6203 ZZ / 6203 ZZ
– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8 12
Elastomer
Silicon carbide Silicon carbide
FLOAT SWITCH (only for single-phase versions)
13
11 9 6
8
4
266
2
3
DIMENSIONS AND WEIGHT Typical installation
e
p (minimum)
h
h1
DN
MODEL
d
a
PORT
Single-phase
Three-phase
RXm 4/40
RX 4/40
RXm 5/40
RX 5/40
(minimum)
DIMENSIONS mm
DN
a
1½"
h
220
h1
430
d
400
kg e
50
variable
p 500
500
1~
3~
13.0
12.2
14.0
13.0
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
VOLTAGE (three-phase)
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
RXm 4/40
5.2 A
5.2 A
10.5 A
RX 4/40
3.6 A
2.1 A
3.6 A
2.1A
RXm 5/40
6.5 A
6.5 A
–
RX 5/40
5.4 A
3.1 A
5.4 A
3.1 A
PALLETIZATION MODEL
GROUPAGE n° H pumps (mm)
Single-phase
Three-phase
RXm 4/40
RX 4/40
45
RXm 5/40
RX 5/40
45
CONTAINER kg
n° H pumps (mm)
1~
3~
1574
602
566
60
1574
647
602
60
kg 1~
3~
2052
797
749
2052
857
797
H
0
80
00
12
267
RX-GM "VORTEX" Submersible pumps ➠ for dirty water
Version with vertical magnetic float switch
PERFORMANCE RANGE
•• Flow rate up to 180 l/min (10.8 m3/h) •• Head up to 9 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage up to Ø 20 mm •• Suction down to 25 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS
INSTALLATION AND USE The RX-VORTEX/GM series pumps are suitable for use with dirty water that does not contain abrasive particles and comes complete with a vertical float switch meaning that the pumps can be used in particularly small spaces. The design solutions that have been adopted, such as the complete cooling of the motor, guarantee the reliability of the pump. They are suitable for use in domestic applications such as for discharging dirty water containing suspended solids.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0013
OPTIONALS AVAILABLE ON REQUEST
Complete with: – 5 m long power cable – vertical magnetic float switch
•• Special mechanical seal •• Pumps with a 10 m long power cable
EN 60335-1 IEC 60335-1 CEI 61-150
••
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
268
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 0
9
10
50 Hz n= 2900 1/min
20
0
30
10
40
20
US g.p.m.
30
40
Imp g.p.m. feet
RX3/20-GM
8
25
7
Head H (metres) 4
RX2/20-GM 20
6 5
15
4 10
3 2
5
1 0
0 0
20 1
40 2
60 3
80 4
100 5
120
6
7
140
160
8
9
180 10
l/min
11
0
m³/h
Flow rate Q 4
MODEL
POWER
Single-phase
kW
HP
RXm 2/20-GM
0.37
0.50
RXm 3/20-GM
0.55
0.75
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.2
2.4
3.6
4.8
6
7.2
8.4
9.6
10.8
l/min
0
20
40
60
80
100
120
140
160
180
7
6.5
6
5.4
4.8
4.3
3.7
3.1
2.5
2
9
8
7.5
6.5
6
5.5
4.7
4.2
3.5
3
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
269
RX-GM "VORTEX" POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
DIFFUSER
Technopolymer
5
IMPELLER
Stainless steel AISI 304 VORTEX type
6
MOTOR CASING
Stainless steel AISI 304
7
MOTOR CASING PLATE
Stainless steel AISI 304
8
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
9
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
AR-12R SIC
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
10
LIP SEAL
Ø 12 x Ø 19 x H 5 mm
11
BEARINGS
6201 ZZ / 6201 ZZ
12
CAPACITOR Pump
13
14
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
RXm 2/20-GM RXm 3/20-GM
10 μF 450 VL 14 μF 450 VL
16 μF 250 VL 16 μF 250 VL
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class. – Protection: IP X8.
14
HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.
1 12
11 6 13 7
11 10
9 4 8
5
270
2
3
DIMENSIONS AND WEIGHT
Typical installation
a
MODEL Single-phase RXm 2/20-GM RXm 3/20-GM
e
g
d
h1
h
p (minimum)
DN
(minimum)
PORT
DIMENSIONS mm
DN
a
1¼”
147
h
h1
305
278
335
308
d 25
e
d
180
50
210
80
kg
p 350
240
6.2 8.0
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
RXm 2/20-GM
2.6 A
2.6 A
6.5 A
RXm 3/20-GM
3.2 A
3.2 A
7.5 A
PALLETIZATION MODEL
GROUPAGE
Single-phase
n° pumps
H (mm)
RXm 2/20-GM
60
RXm 3/20-GM
60
CONTAINER kg
n° pumps
H (mm)
kg
1489
396
75
1844
489
1696
504
75
2084
624
H
0
80
00
12
271
ZX
"VORTEX"
Submersible pumps ➠ for very dirty water
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
ZX series pumps are suitable for draining waste water in domestic applications and for pumping dirty water containing suspended solids up to Ø 40 mm. They distinguish themselves for the ease with which they are installed and their reliability under automatic operating conditions in fixed installations.
•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 11 m •• 5 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 40 mm •• Suction down to 50 mm above ground level •• 240 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 5 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0015
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal. •• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
272
1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
ZXm1A
Head H (metres) 4
ZXm1B
Flow rate Q 4
MODEL Single-phase
POWER kW
HP
ZXm 1B/40
0.50
0.70
ZXm 1A/40
0.60
0.85
Q = Flow rate H = Total manometric head
Q
m³/h
0
1.5
3.0
4.5
6.0
9.0
12.0
15.0
18.0
21.0
24.0
l/min
0
25
50
75
100
150
200
250
300
350
400
9
8.5
8.3
8
7.5
6.5
5.2
4
2.5
1
11
10.5
10
9.5
9.2
8.2
7
5.7
4.3
2.8
H metres
1.5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
273
ZX
"VORTEX"
POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Technopolymer VORTEX type
4
MOTOR SLEEVE
Stainless steel AISI 304
5
MOTOR CASING
Steel
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
8
LIP SEAL
Ø 12 x Ø 22 x H 6 mm
9
BEARINGS
6201 ZZ / 6201 ZZ
10
CAPACITOR Pump
11
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
ZXm 1B/40 ZXm 1A/40
12.5 μF 450 VL 16 μF 450 VL
30 μF 250 VL 30 μF 250 VL
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8.
12
12
POWER CABLE
10
5 metre long “H07 RN-F” cable with Schuko plug 13
14
9
FLOAT SWITCH (only for single-phase versions)
5
HOSE CONNECTION
4
Ø 50 mm 11
6
9 8 7
14 13 1 2
274
3
DIMENSIONS AND WEIGHT Typical installation
DN
e
h
p (minimum)
a
d
h1
c
(minimum)
b
MODEL Single-phase ZXm 1B/40 ZXm 1A/40
PORT
DIMENSIONS mm
solids passage
DN 1½”
a
Ø 40 mm
75
b 87
c 130
h 378
h1 82
d
kg e
50
1~
p
variable
450
450
11.5 11.7
ABSORPTION MODEL Single-phase
VOLTAGE (single-phase) 230 V
240 V
110 V
ZXm 1B/40
3.3 A
3.3 A
7.0 A
ZXm 1A/40
4.5 A
4.5 A
9.0 A
PALLETIZATION MODEL Single-phase
GROUPAGE n° pumps
CONTAINER
H (mm)
kg
n° pumps
H (mm)
kg
ZXm 1B/40
60
1460
709
80
1900
940
ZXm 1A/40
60
1460
721
80
1900
956
H
0
80
00
12
275
ZD Submersible drainage pumps ➠ for clear water
PERFORMANCE RANGE
•• Flow rate up to 300 l/min (18 m3/h) •• Head up to 14 m
APPLICATION LIMITS
•• 5 m maximum immersion depth
INSTALLATION AND USE Designed to pump clear or slightly dirty water, these pumps are suitable for use in domestic applications and in particular for draining flooded areas such as cellars or for emptying tanks and reservoirs; they distinguish themselves for the ease with which they are installed and their reliability under automatic operating conditions in fixed installations.
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 10 mm •• Suction down to 21 mm above ground level •• 180 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 5 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
276
OPTIONALS AVAILABLE ON REQUEST
•• Special mechanical seal. •• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 10
0
15
20
30
10
0
50 Hz n= 2900 1/min 40
20
50
30
60
40
70
50
US g.p.m. 60
Imp. g.p.m.
feet
14 ZDm1AR-E
45
13 40
12
Head H (metres) 4
11 ZDm1A-E
35
10 30
9 ZDm1B-E
8
25
7 20
6 5
15
4 10
3 2
5
1 0
0
25
50
75
MODEL
125
5
0
POWER kW
HP
ZDm 1B-E
0.37
0.50
ZDm 1A-E
0.50
0.70
ZDm 1AR-E
0.60
0.85
Single-phase
100
Q = Flow rate H = Total manometric head
Q
150
175
200
225
250
10
275
300
m3/h
15
Flow rate Q 4
0
l/min
m³/h
0
1.5
3.0
4.5
6.0
7.5
9.0
10.5
12.0
13.5
15.0
16.5
18.0
l/min
0
25
50
75
100
125
150
175
200
225
250
275
300
8.5
8
7.5
6.5
5.5
4.8
3.5
2.5
1
11
10.5
10
9
8.5
7.5
6.5
5.5
4
2.5
1.5
14
13.5
13
12.2
11.5
10.5
9.5
8.3
7
5.7
4.5
3.2
2
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
277
ZD POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Noryl GFN2V open type
5
MOTOR SLEEVE
Stainless steel AISI 304
6
MOTOR CASING
Steel
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE SEAL Seal
Shaft
Model
Diameter
AR-12R
Ø 12 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Graphite
NBR
9
LIP SEAL
Ø 12 x Ø 22 x H 6 mm
10
BEARINGS
6201 ZZ / 6201 ZZ
11
CAPACITOR Pump
12
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
ZDm 1B-E ZDm 1A-E ZDm 1AR-E
10 μF 450 VL 12.5 μF 450 VL 16 μF 450 VL
16 μF 250 VL 30 μF 250 VL 30 μF 250 VL 13
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8.
13
11
POWER CABLE 10
5 metre long “H07 RN-F” cable with Schuko plug 14
6
FLOAT SWITCH (only for single-phase versions)
5 14 12 10 9
7
1
278
2
8
4
3
DIMENSIONS AND WEIGHT
Typical installation
d
h1
DN
e
h
p (minimum)
a
b
MODEL Single-phase
(minimum)
c
PORT
DIMENSIONS mm
DN
a
b
c
h
h1
d
e
kg
p
10.9
ZDm 1B-E ZDm 1A-E
1½”
110
81
142
316
77
21
variable
450
450
11.5 11.8
ZDm 1AR-E
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
110 V
ZDm 1B-E
2.5 A
2.5 A
5.2 A
ZDm 1A-E
3.3 A
3.3 A
7.0 A
ZDm 1AR-E
4.4 A
4.4 A
9.0 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
ZDm 1B-E
60
ZDm 1A-E
60
ZDm 1AR-E
60
Single-phase
CONTAINER kg
n° pumps
H (mm)
kg
1250
670
100
1990
1106
1250
709
100
1990
1170
1250
726
100
1990
1199
H
0 80
00
12
279
D Submersible drainage pumps ➠ for clear water
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Designed to pump clear or slightly dirty water, these pumps are suitable for use in domestic, civil and professional applications and in particular for draining flooded areas such as cellars and garages, for draining swimming pools and reservoirs and for the disposal of non-sewage waste water. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 27 m •• 5 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: •• ••
– up to Ø 10 mm for D8-D10-D15 – up to Ø 6 mm for D18-D20 – up to Ø 3 mm for D30 Suction level: – 23 mm above ground level for D8-D10-D18-D20 – 15 mm above ground level for D15-D30 220 mm minimum immersion depth for continuous service
CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 5 m long power cable •• Float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
280
PATENTS - TRADE MARKS - MODELS
•• Patent n° IT1390742, IT1390743
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
D30
D15
Head H (metres) 4
D20
D18 D10 D8
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase
kW
HP
Q
m³/h
0
1.5
3.0
4.5
6.0
l/min
0
25
50
75
100 125 150 175 200 225 250 275 300 325 350 400
7.5
Dm 8
–
0.55
0.75
12
11.5
11
10.5
Dm 10
D 10
0.75
1
15
14.5
14
13.2 12.5 11.8
Dm 15
D 15
1.1
1.5
Dm 18
–
0.55
0.75
Dm 20
D 20
0.75
Dm 30
D 30
1.1
Q = Flow rate H = Total manometric head
23
22
17
16.5
1
21
20
19
17.5
1.5
27
26
25
23.5
H metres
21.5 20.5 15
13.5
9.8
9
9.0
10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 24.0
8.2
7.2
6
4.8
3.5
2
11
10
9
8
6.8
5.4
3.5
2
15
13.5
12
11
9
14.5
13
11.5
10
20
19
18
17
16
12
10.7
9
7.7
5
16
15
13.5
12
10
22
21
19.5
18
16
7.5
4
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
281
D POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304 (with mesh filter for D30)
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Technopolymer open type (closed for D30)
5
MOTOR CASING
Stainless steel AISI 304
6
MOTOR CASING PLATE
Stainless steel AISI 304
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
9
LIP SEAL
Ø 15 x Ø 24 x H 5 mm (Ø 16 x Ø 24 x H 5 mm for D15, D30)
10
BEARINGS
6203 ZZ / 6203 ZZ
11
CAPACITOR Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
20 μF 450 VL
30 μF 250 VL
25 μF 450 VL
–
Dm8 Dm10 Dm18 Dm20 Dm15 Dm30 12
13
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
13
11
POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
14
10
FLOAT SWITCH
5
(only for single-phase versions)
12 9 7 14 10 6
1
282
2
8
4
3
DIMENSIONS AND WEIGHT a
b
MODEL Single-phase Dm 8
c
PORT
Three-phase D 10
Dm 15
D 15
Dm 18
1½”
–
Dm 20
D 20
Dm 30
D 30
(minimum)
DIMENSIONS mm
DN
–
Dm 10
d
h1
DN
e
h
p (minimum)
Typical installation
a
b
c
h
h1
d
105
81
136
352
72
23
110
90
140
371
85
15
105
81
136
352
72
23
110
90
140
371
85
15
kg e
1~
p
variable
500
500
3~
11.7
–
12.7
11.6
14.7
13.7
11.8
–
13.0
11.7
15.0
14.0
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
Single-phase
230 V
240 V
VOLTAGE (three-phase)
110 V
Three-phase
230 V
400 V
240 V
415 V
Dm 8
3.4 A
3.4 A
6.9 A
D 10
3.6 A
2.1 A
3.6 A
2.1 A
Dm 10
5.2 A
5.2 A
10.5 A
D 15
6.0 A
3.5 A
6.0 A
3.5 A
Dm 15
7.9 A
7.9 A
–
D 20
3.6 A
2.1 A
3.6 A
2.1 A
Dm 18
3.8 A
3.8 A
7.2 A
D 30
6.0 A
3.5 A
6.0 A
3.5 A
Dm 20
5.4 A
5.4 A
11.0 A
Dm 30
7.2 A
7.2 A
–
PALLETIZATION MODEL Single-phase Dm 8
Three-phase –
Dm 10
D 10
Dm 15
D 15
Dm 18
–
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
60
1310
60
1310
kg
3~
n° pumps
H (mm)
1~
720
–
100
2090
1190
780
711
100
2090 1288
1174 837
3~ –
45
1388
678
632
60
1804
898
60
1310
725
–
100
2090
1197
–
60
1310
797
720
100
2090
1317
1188
Dm 30
D 30
45
1388
690
647
60
1804
914
857
0
D 20
80
Dm 20
H
00
12
283
VX-I "VORTEX" Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 10 m
APPLICATION LIMITS
•• 5 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: ••
– up to Ø 40 mm for VX8/35I - VX10/35I – up to Ø 50 mm for VX8/50I - VX10/50I Minimum immersion depth for continuous service: – 270 mm for VX8/35I - VX10/35I – 300 mm for VX8/50I - VX10/50I
CONSTRUCTION AND SAFETY STANDARDS
INSTALLATION AND USE Suitable for use with sewage water in domestic, civil and industrial applications or in any other situation, such as with water mixed with mud, with groundwater and with surface water, where the water contains suspended solids. They are suitable for use in applications such as for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
PATENTS - TRADE MARKS - MODELS
•• Patent n° IT1390742, IT1390743
OPTIONALS AVAILABLE ON REQUEST
•• Complete with 5 m long power cable •• Float switch for single-phase versions
•• Pumps with a 10 m long power cable
EN 60335-1 IEC 60335-1 CEI 61-150
•• ••
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
284
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
VX10/35-I
VX8/35-I
Head H (metres) 4
VX10/50-I
VX8/50-I
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase
kW
HP
VXm 8/35-I
–
Q
m³/h
0
3
6
9
12
15
18
21
24
l/min
0
50
100
150
200
250
300
350
400
0.55
0.75
8.4
7.5
6.5
5.2
3.7
2
VXm 10/35-I VX 10/35-I
0.75
1
10
9.5
8.5
7.2
5.8
4
VXm 8/50-I
0.55
0.75
6
5.5
5
4.4
3.6
2.8
2
1
0.75
1
7.5
7
6.5
5.8
5
4
3.2
2.4
–
VXm 10/50-I VX 10/50-I
Q = Flow rate H = Total manometric head
H metres
2 1.5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
285
VX-I "VORTEX" POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 VORTEX type
4
MOTOR CASING
Stainless steel AISI 304
5
MOTOR CASING PLATE
Stainless steel AISI 304
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
8
LIP SEAL
Ø 15 x Ø 24 x H 5 mm
9
BEARINGS
6203 ZZ / 6203 ZZ
10
CAPACITOR
11
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
VXm 8/35-I VXm 8/50-I VXm 10/35-I VXm 10/50-I
20 μF 450 VL
30 μF 250 VL
12
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
12
10 9 4
POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
13
6 11
FLOAT SWITCH
8
9
(only for single-phase versions)
13
5 7
1 2
286
3
DIMENSIONS AND WEIGHT Typical installation
e d
h1
DN
h
p (minimum)
a
(minimum)
b
MODEL
PORT
Single-phase
Three-phase
VXm 8/35-I
–
VXm 10/35-I
VX 10/35-I
VXm 8/50-I
–
VXm 10/50-I
VX 10/50-I
DN 1½”
DIMENSIONS mm
solids passage
a
Ø 40 mm
b
108
h
h1
404
d
87
Ø 50 mm
118
e
p
50
166 2”
kg
variable 434
108
500
500
60
1~
3~
9.5
–
10.8
9.3
9.4
–
10.6
9.2
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
VXm 8/35-I
3.3 A
3.3 A
7.6 A
VX 10/35-I
3.6 A
2.1 A
3.6 A
2.1 A
VXm 10/35-I
5.0 A
5.0 A
11.5 A
VX 10/50-I
3.6 A
2.1 A
3.6 A
2.1 A
VXm 8/50-I
3.5 A
3.5 A
8.0 A
VXm 10/50-I
5.0 A
5.0 A
11.5 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
kg
3~
n° pumps
H (mm)
1~
3~
Single-phase
Three-phase
VXm 8/35-I
–
60
1520
588
–
80
1980
778
–
VXm 10/35-I
VX 10/35-I
60
1520
662
576
80
1980
877
762
VXm 8/50-I
–
60
1520
579
–
80
1980
766
–
VXm 10/50-I
VX 10/50-I
60
1520
652
569
80
1980
864
753
H
0
80
00
12
287
MC-I
"DOUBLE-CHANNEL"
Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 800 l/min (48 m3/h) •• Head up to 15 m
APPLICATION LIMITS
•• 5 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 50 mm •• 300 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 5 m long power cable •• Float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
288
INSTALLATION AND USE MC-I submersible pumps are suitable for draining dirty water and sewage in domestic and civil applications. They come equipped with a DOUBLE-CHANNEL impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage water, waste water, surface water and water mixed with mud in locations such as holiday homes and detached homes. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
PATENTS - TRADE MARKS - MODELS
•• Patent n° IT1390742, IT1390743
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 20
0
16
0
40
60
20
40
80
50 Hz n= 2900 1/min
100
60
120
80
140
100
160
120
180
200
140
220
160
180 feet 50
MC15/50-I
14
45
40
12
Head H (metres) 4
MC10/50-I
35
10 30
8
25
6
20
15
4
10
2 5
0
100
0
200
300
10
0
400 20
MODEL
POWER
Single-phase Three-phase
kW
MCm 10/50-I
MC 10/50-I
0.75
1
–
MC 15/50-I
1.1
1.5
Q = Flow rate H = Total manometric head
HP
Q
500
600
700
30
0
800
40
Flow rate Q 4
50
m³/h
0
3
6
9
12
15
18
21
24
27
30
36
42
48
l/min
0
50
100
150
200
250
300
350
400
450
500
600
700
800
12
10.7
9.7
8.7
7.8
6.8
5.9
5
4
3
2
15
14
13
12.3
11.5
10.5
9.7
8.8
8
7
6.2
4.5
2.7
1
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
289
MC-I
"DOUBLE-CHANNEL"
POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Stainless steel AISI 304, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 DOUBLE-CHANNEL type
4
MOTOR CASING
Stainless steel AISI 304
5
MOTOR CASING PLATE
Stainless steel AISI 304
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
8
LIP SEAL
Ø 15 x Ø 24 x H 5 mm
9
BEARINGS
6203 ZZ / 6203 ZZ
10
CAPACITOR Capacitance
11
(230 V or 240 V)
(110 V)
20 μF 450 VL
30 μF 250 VL
12
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
12
10
9
POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
13
4
FLOAT SWITCH
6
(only for single-phase versions)
11
8
9
13
5 7
1 2
290
3
DIMENSIONS AND WEIGHT Typical installation
e d
h1
DN
h
p (minimum)
a
(minimum)
b
MODEL
PORT
Single-phase
Three-phase
MCm 10/50-I
MC 10/50-I
–
MC 15/50-I
DIMENSIONS mm
solids passage
DN 2”
a
Ø 50 mm
b
118
h
166
h1
434
108
d 60
kg e
variable
1~
3~
10.9
9.5
–
10.5
p 500
500
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
MCm 10/50-I
5.0 A
5.0 A
11.5 A
MC 10/50-I MC 15/50-I
415 V
3.6 A
2.1 A
3.6 A
2.1 A
6.1 A
3.5 A
6.1 A
3.5 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
1~
3~
MC 10/50-I
60
1520
671
588
80
1980
889
778
MC 15/50-I
60
1520
–
645
80
1980
–
854
Single-phase
Three-phase
MCm 10/50-I –
H
0 80
00
12
291
VX
"VORTEX"
Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
Suitable for use in domestic, civil and industrial applications where the water, such as groundwater, surface water and sewage water, contains suspended solids up to Ø 50 mm. They are suitable for use in applications such as for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
•• Flow rate up to 500 l/min (30 m³/h) •• Head up to 15 m •• 5 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: ••
– up to Ø 40 mm for VX8-10-15/35 – up to Ø 50 mm for VX8-10-15/50 Minimum immersion depth for continuous service: – 290 mm for VX8-10-15/35 – 320 mm for VX8-10-15/50
CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 5 m long power cable •• VXm versions complete with float switch EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
PATENTS - TRADE MARKS - MODELS
•• Patent n° IT1390742, IT1390743
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
292
1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
VX15/35
Head H (metres) 4
VX15/50 VX10/35
VX8/35 VX10/50 VX8/50
Flow rate Q 4
MODEL
POWER
Single-phase Three-phase VXm 8/35
–
VXm 10/35
VX 10/35
VXm 15/35
VX 15/35
VXm 8/50
–
Q
m³/h
0
3
6
9
12
15
18
21
24
27
30
l/min
0
50
100
150
200
250
300
350
400
450
500
7.5
6.5
5.2
3.7
2
9.5
8.5
7.2
5.8
4
2
14
13
11.8
10.5
9
7.5
6
4
2
5.5
5
4.4
3.6
2.8
2
1
kW
HP
0.55
0.75
8.4
0.75
1
10 15 6
1.1
1.5
0.55
0.75
H metres
VXm 10/50
VX 10/50
0.75
1
7.5
7
6.5
5.8
5
4
3.2
2.4
1.5
VXm 15/50
VX 15/50
1.1
1.5
11
10.5
10
9.5
9
8.3
7.5
6.8
6
Q = Flow rate H = Total manometric head
5
4
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
293
VX
"VORTEX"
POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 VORTEX type
4
MOTOR CASING
Stainless steel AISI 304
5
MOTOR CASING PLATE
Stainless steel AISI 304
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
8
LIP SEAL
Ø 15 x Ø 24 x H 5 mm for VX 8-10/35-50 Ø 16 x Ø 24 x H 5 mm for VX 15/35-50
9
BEARINGS
6203 ZZ / 6203 ZZ
10
CAPACITOR Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
20 μF 450 VL
30 μF 250 VL
25 μF 450 VL
–
VXm 8/35 VXm 8/50 VXm 10/35 VXm 10/50 VXm 15/35 VXm 15/50 11
12
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
12
10 9 4
POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
13
FLOAT SWITCH (only for single-phase versions)
9
6
8
5
13
7
1 2
294
11
3
DIMENSIONS AND WEIGHT Typical installation
d
h1
DN
e
p (minimum)
h
a
b
MODEL
PORT
Single-phase
Three-phase
VXm 8/35
–
VXm 10/35
VX 10/35
VXm 15/35
VX 15/35
VXm 8/50
–
VXm 10/50
VX 10/50
VXm 15/50
VX 15/50
(minimum)
c
DIMENSIONS mm
solids passage
DN 1½”
a
b
105
Ø 40 mm
92 110 2”
Ø 50 mm 115
97
c
h
h1
136
408
125
143
429
130
150
437
153
157
458
159
kg
d
e
p
50 variable
500
500
60
1~
3~
12.4
–
13.3
12.1
16.3
15.0
12.9
–
13.9
12.1
17.0
15.6
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
VXm 8/35
3.3 A
3.3 A
7.6 A
VX 10/35
3.6 A
2.1 A
3.6 A
2.1 A
VXm 10/35
5.0 A
5.0 A
11.5 A
VX 15/35
5.4 A
3.1 A
5.4 A
3.1 A
VXm 15/35
6.7 A
6.7 A
–
VX 10/50
3.6 A
2.1 A
3.6 A
2.1 A
VXm 8/50
3.5 A
3.5 A
8.0 A
VX 15/50
5.4 A
3.1 A
5.4 A
3.1 A
VXm 10/50
5.0 A
5.0 A
11.5 A
VXm 15/50
7.1 A
7.1 A
–
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
1~
3~
n° pumps
–
60
1520
761
–
80
VXm 10/35
VX 10/35
60
1520
815
744
VXm 15/35
VX 15/35
45
1574
748
692
VXm 8/50
–
60
1520
791
VXm 10/50
VX 10/50
60
1520
VXm 15/50
VX 15/50
45
1574
VXm 8/35
H (mm)
kg 1~
3~
1980 1009
–
80
1980 1081
987
60
2052
917
–
80
1980 1049
851
744
80
1980
1129
986
780
718
60
2052 1034
952
992
H
– 0
H (mm)
Three-phase
80
n° pumps
Single-phase
00
12
295
MC
"DOUBLE-CHANNEL"
Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 800 l/min (48 m³/h) •• Head up to 15 m
APPLICATION LIMITS
•• 5 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 50 mm •• 320 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 5 m long power cable •• Float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE MC submersible pumps are suitable for draining dirty water and sewage in domestic and civil applications. They come equipped with a DOUBLE-CHANNEL stainless steel impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage water, waste water, surface water and water mixed with mud in locations such as holiday homes and detached homes. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
PATENTS - TRADE MARKS - MODELS
•• Patent n° IT1390742, IT1390743
OPTIONALS AVAILABLE ON REQUEST
•• Pumps with a 10 m long power cable •• ••
➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
296
CHARACTERISTIC CURVES AND PERFORMANCE DATA 20
0
16
0
40
60
20
40
80
50 Hz n= 2900 1/min
100
60
120
80
140
100
160
120
180
200
140
220
160
180 feet 50
14 MC12/50
45
40
12
Head H (metres) 4
MC10/50
35
10 30
8
25
6
20
15
4
10
2 5
0
100
0
200
300
10
0
400 20
MODEL
POWER
Single-phase Three-phase
kW
MCm 10/50
MC 10/50
0.75
1
MCm 12/50
MC 12/50
1.1
1.5
Q = Flow rate H = Total manometric head
HP
Q
500
600
700
30
0
800
40
Flow rate Q 4
50
m³/h
0
3
6
9
12
15
18
21
24
27
30
36
42
48
l/min
0
50
100
150
200
250
300
350
400
450
500
600
700
800
12
10.7
9.7
8.7
7.8
6.8
5.9
5
4
3
2
15
14
13
12.3
11.5
10.5
9.7
8.8
8
7
6.2
4.5
2.7
1
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
297
MC
"DOUBLE-CHANNEL"
POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 DOUBLE-CHANNEL type
4
MOTOR CASING
Stainless steel AISI 304
5
MOTOR CASING PLATE
Stainless steel AISI 304
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
8
LIP SEAL
Ø 15 x Ø 24 x H 5 mm for MC 10/50 Ø 16 x Ø 24 x H 5 mm for MC 12/50
9
BEARINGS
6203 ZZ / 6203 ZZ
10
CAPACITOR
11
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
MCm 10/50 MCm 12/50
20 μF 450 VL 25 μF 450 VL
30 μF 250 VL –
12
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
12
10
POWER CABLE
4
5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only) 13
9
11 9
FLOAT SWITCH
6
(only for single-phase versions)
5
8 13
7
1 3 2
298
DIMENSIONS AND WEIGHT Typical installation
d
h1
DN
e
p (minimum)
h
a
b
MODEL
PORT
Single-phase
Three-phase
MCm 10/50
MC 10/50
MCm 12/50
MC 12/50
(minimum)
c
DIMENSIONS mm
solids passage
DN 2”
Ø 50 mm
a
b
c
h
h1
110
92
150
437
153
115
97
157
458
159
kg
d 60
e
1~
3~
14.1
12.9
17.0
15.8
p
variable
500
500
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
MCm 10/50
5.2 A
5.2 A
11.7 A
MC 10/50
3.6 A
2.1 A
3.6 A
2.1 A
MCm 12/50
8.5 A
8.5 A
–
MC 12/50
6.1 A
3.5 A
6.1 A
3.5 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
1~
3~
MC 10/50
60
1520
865
791
80
1980
1148
1049
MC 12/50
45
1574
784
730
60
2052
1039
968
Single-phase
Three-phase
MCm 10/50 MCm 12/50
H
0 80
00
12
299
DC Submersible drainage pumps ➠ for clear water
PERFORMANCE RANGE
•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 27 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: •• ••
– up to Ø 10 mm for DC8-DC10-DC15 – up to Ø 6 mm for DC20 – up to Ø 3 mm for DC30 Suction level: – 23 mm above ground level for DC8-DC10-DC20 – 15 mm above ground level for DC15-DC30 220 mm minimum immersion depth for continuous service
CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3
300
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE DC submersible pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, are suitable for draining clear or slightly dirty water. They distinguish themselves for their sturdiness and reliability under automatic operating conditions in fixed installations.
OPTIONALS AVAILABLE ON REQUEST
•• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
DC30
DC15
Head H (metres) 4
DC20
DC10 DC8
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
m³/h
0
1.5
3.0
4.5
6.0
l/min
0
25
50
75
100 125 150 175 200 225 250 275 300 325 350 400
7.5
9.0
10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 24.0
DCm 8
–
0.55
0.75
12
11.5
11
10.5
DCm 10
DC 10
0.75
1
15
14.5
14
13.2 12.5 11.8
DCm 15
DC 15
1.1
1.5
H metres 23
22
20
19
18
DCm 20
DC 20
0.75
1
21
20
19
17.5
16
15
13.5
DCm 30
DC 30
1.1
1.5
27
26
25
23.5
22
21
19.5
18
16
Q = Flow rate H = Total manometric head
21.5 20.5
9.8
9
8.2
7.2
6
4.8
3.5
2
11
10
9
8
6.8
5.4
3.5
2
17
16
15
13.5
12
11
9
12
10 14.5
13
11.5
10
7.5
4
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
301
DC POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
SUCTION FILTER
Stainless steel AISI 304 (with mesh filter for DC30)
3
SUCTION PLATE
Stainless steel AISI 304
4
IMPELLER
Technopolymer open type (closed for DC30)
5
MOTOR CASING
Cast iron
6
MOTOR CASING PLATE
Stainless steel AISI 304
7
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
8
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
9
LIP SEAL
Ø 15 x Ø 24 x H 5 mm for DC8, DC10, DC 20 Ø 16 x Ø 24 x H 5 mm for DC15, DC30
10
BEARINGS
6203 ZZ / 6203 ZZ
11
CAPACITOR Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
20 μF 450 VL
30 μF 250 VL
25 μF 450 VL
–
DCm8 DCm10 DCm20 DCm15 DCm30 12
13
11
ELECTRIC MOTOR
10
– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8 13
5 7 12
POWER CABLE
9
10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only) 14
10
14
6
FLOAT SWITCH (only for single-phase versions)
1
302
2
8
4
3
DIMENSIONS AND WEIGHT Typical installation
d
h1
DN
e
h
p (minimum)
a
c
MODEL
(minimum)
b
PORT DN
DIMENSIONS mm
Single-phase
Three-phase
a
DCm 8
–
DCm 10
DC 10
DCm 15
DC 15
DCm 20
DC 20
105
DCm 30
DC 30
110
b
105 1½”
92
110
kg e
1~
p
3~
c
h
h1
d
136
324
72
23
140
343
85
15
136
324
72
23
140
343
85
15
21.5
19.9
variable
500
500
18.6
–
19.5
17.9
21.6
19.9
19.5
17.9
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
DCm 8
3.4 A
3.4 A
6.9 A
DC 10
3.6 A
2.1 A
3.6 A
2.1 A
DCm 10
5.2 A
5.2 A
10.5 A
DCm 15
7.9 A
7.9 A
–
DC 15
6.1 A
3.5 A
6.1 A
3.5 A
DCm 20
5.4 A
5.4 A
11.0 A
DC 20
3.6 A
2.1 A
3.6 A
2.1 A
DCm 30
7.2 A
7.2 A
–
DC 30
6.1 A
3.5 A
6.1 A
3.5 A
PALLETIZATION MODEL
GROUPAGE n° pumps
H (mm)
–
45
1388
DC 10
45
1388
Single-phase
Three-phase
DCm 8 DCm 10
CONTAINER kg
kg
3~
n° pumps
H (mm)
854
–
60
1804
1133
–
894
824
60
1804
1187
1093
1~
1~
3~
DCm 15
DC 15
45
1388
987
913
60
1804
1310
1211
DCm 20
DC 20
45
1388
895
824
60
1804
1187
1093
DCm 30
DC 30
45
1388
985
910
60
1804 1308
1208
H
0
80
00
12
303
VXC "VORTEX" Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 500 l/min (30 m³/h) •• Head up to 15 m
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
APPLICATION LIMITS
•• 10 m maximum immersion depth •• •• ••
(with a sufficiently long power cable) Maximum liquid temperature +40 °C Solids passage: – up to Ø 40 mm for VXC 8-10-15/35 – up to Ø 50 mm for VXC 8-10-15/45 Minimum immersion depth for continuous service: – 290 mm for VXC 8-10-15/35 – 320 mm for VXC 8-10-15/45
CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3
304
INSTALLATION AND USE VXC series pumps, made from heavy gauge cast iron offering exceptional sturdiness and abrasion resistance, come equipped with a VORTEX impeller and are therefore suitable for draining waste water containing suspended solids, sewage and water mixed with mud.
OPTIONALS AVAILABLE ON REQUEST
•• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
VXC15/35
Head H (metres) 4
VXC15/45 VXC10/35
VXC8/35 VXC10/45 VXC8/45
Flow rate Q 4
MODEL
POWER
Q
m³/h
0
3
6
9
12
15
18
21
24
27
30
l/min
0
50
100
150
200
250
300
350
400
450
500
7.5
6.5
5.2
3.7
2
9.5
8.5
7.2
5.8
4
2
14
13
11.8
10.5
9
7.5
6
4
2
5.5
5
4.4
3.6
2.8
2
1
Single-phase Three-phase
kW
HP
VXCm 8/35
0.55
0.75
8.4
0.75
1
10 15 6
–
VXCm 10/35 VXC 10/35 VXCm 15/35 VXC 15/35
1.1
1.5
0.55
0.75
VXCm 10/45 VXC 10/45
0.75
1
7.5
7
6.5
5.8
5
4
3.2
2.4
1.5
VXCm 15/45 VXC 15/45
1.1
1.5
11
10.5
10
9.5
9
8.3
7.5
6.8
6
VXCm 8/45
–
Q = Flow rate H = Total manometric head
H metres
5
4
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
305
VXC "VORTEX" POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 VORTEX type
4
MOTOR CASING
Cast iron
5
MOTOR CASING PLATE
Stainless steel AISI 304
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
8
LIP SEAL
Ø 15 x Ø 24 x H 5 mm for VXC 8-10/35-45 Ø 16 x Ø 24 x H 5 mm for VXC 15/35-45
9
BEARINGS
6203 ZZ / 6203 ZZ
10
CAPACITOR Pump
Capacitance
Single-phase
(230 V or 240 V)
VXCm 8/35 VXCm 8/45 VXCm 10/35 VXCm 10/45 VXCm 15/35 VXCm 15/45 11
(110 V)
12
20 μF 450 VL
30 μF 250 VL
25 μF 450 VL
–
10 9
ELECTRIC MOTOR
6
– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8 12
4 11 9
POWER CABLE
13
13
8
10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
5
FLOAT SWITCH (only for single-phase versions)
1 2 7
306
3
DIMENSIONS AND WEIGHT Typical installation
c
MODEL Single-phase
e (minimum)
b
PORT
Three-phase
VXCm 8/35
–
VXCm 10/35
VXC 10/35
VXCm 15/35
VXC 15/35
VXCm 8/45
–
VXCm 10/45
VXC 10/45
VXCm 15/45
VXC 15/45
d
h1
h
DN
p (minimum)
a
DN
solids passage
1½”
Ø 40 mm
DIMENSIONS mm a
b
105 92 110
2”
Ø 50 mm 115
97
c
h
h1
136
380
125
143
401
130
150
409
153
157
430
159
kg
d
e
1~
p
50 variable
500
500
60
3~
19.8
–
20.0
18.3
22.8
24.4
20.5
–
20.5
18.7
23.5
21.1
ABSORPTION MODEL
VOLTAGE (single-phase)
MODEL
VOLTAGE (three-phase)
Single-phase
230 V
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
VXCm 8/35
3.3 A
3.3 A
7.6 A
VXC 10/35
3.6 A
2.1 A
3.6 A
2.1 A
VXCm 10/35
5.0 A
5A
11.5 A
VXCm 15/35
6.7 A
6.7 A
–
VXC 15/35
5.4 A
3.1 A
5.4 A
3.1 A
VXCm 8/45
3.5 A
3.5 A
8.0 A
VXC 10/45
6.6 A
2.1 A
6.6 A
2.1 A
VXCm 10/45
5.0 A
5.0 A
11.5 A
VXCm 15/45
7.1 A
7.1 A
–
VXC 15/45
5.4 A
3.1 A
5.4 A
3.1 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
n° pumps
H (mm)
1~
kg
3~
n° pumps
H (mm)
1~
3~
Single-phase
Three-phase
VXCm 8/35
–
45
1400
908
–
60
1820
1205
–
VXCm 10/35
VXC 10/35
45
1400
917
838
60
1820
1217
1112
VXCm 15/35
VXC 15/35
45
1574
1042
935
60
2052 1384
1241
VXCm 8/45
–
45
1400
942
–
60
1820
VXCm 10/45
VXC 10/45
45
1400
940
859
60
1820
1247
1140
VXCm 15/45
VXC 15/45
45
1574
1076
967
60
2052
1429
1283
1250
H
– 0 80
00
12
307
MC
"DOUBLE-CHANNEL"
Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
MC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a DOUBLE-CHANNEL impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage, waste water, water mixed with mud, groundwater and surface water in locations such as apartment blocks, factories, tower garages, underground car parks and cleaning areas, etc.
•• Flow rate up to 800 l/min (48 m3/h) •• Head up to 15 m •• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 50 mm •• 320 mm minimum immersion depth for continuous service
OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
308
•• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
CHARACTERISTIC CURVES AND PERFORMANCE DATA 20
0
16
0
40
60
20
80
40
100
60
50 Hz n= 2900 1/min 120
80
140
100
160
120
180
200
140
220
160
180 feet 50
14
MC15/45 45
40
12
Head H (metres) 4
MC10/45
35
10 30
8
25
6
20
15
4
10
2 5
0
100
0
200
300
10
0
400 20
MODEL
POWER
Single-phase Three-phase
kW
MCm 10/45
MC 10/45
0.75
1
MCm 15/45
MC 15/45
1.1
1.5
Q = Flow rate H = Total manometric head
HP
Q
500
600
700
30
40
Flow rate Q 4
0
800 50
m³/h
0
3
6
9
12
15
18
21
24
27
30
36
42
48
l/min
0
50
100
150
200
250
300
350
400
450
500
600
700
800
12
10.7
9.7
8.7
7.8
6.8
5.9
5
4
3
2
15
14
13
12.3
11.5
10.5
9.7
8.8
8
7
6.2
4.5
2.7
1
H metres
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
309
MC
"DOUBLE-CHANNEL"
POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 DOUBLE-CHANNEL type
4
MOTOR CASING
Cast iron
5
MOTOR CASING PLATE
Stainless steel AISI 304
6
MOTOR SHAFT
Stainless steel EN 10088-3 - 1.4104
7
SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal
Shaft
Model
Diameter
MG1-14 SIC
Ø 14 mm
Materials Stationary ring
Rotational ring
Elastomer
Ceramic
Silicon carbide
NBR
8
LIP SEAL
Ø 15 x Ø 24 x H 5 mm for MC 10/45 Ø 16 x Ø 24 x H 5 mm for MC 15/45
9
BEARINGS
6203 ZZ / 6203 ZZ
10
CAPACITOR
11
Pump
Capacitance
Single-phase
(230 V or 240 V)
(110 V)
MCm 10/45 MCm 15/45
20 μF 450 VL 25 μF 450 VL
30 μF 250 VL –
12
ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8
12
10 9 6 4
POWER CABLE 10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)
13
11 9
FLOAT SWITCH
8
(only for single-phase versions)
13
5
1 2
3 7
310
DIMENSIONS AND WEIGHT Typical installation
d
h1
h
DN
e
p (minimum)
a
b
MODEL Single-phase
Three-phase
MCm 10/45
MC 10/45
MCm 15/45
MC 15/45
c
(minimum)
PORT DN
solids passage
2”
Ø 50 mm
DIMENSIONS mm a
b
c
h
h1
110
92
150
409
153
115
97
157
430
159
kg
d
e
p
60
variable
500
500
1~
3~
20.8
19.2
23.7
21.8
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
VOLTAGE (three-phase)
240 V
110 V
Three-phase
230 V
400 V
240 V
415 V
MCm 10/45
5.2 A
5.2 A
11.5 A
MC 10/45
3.6 A
2.1 A
3.6 A
2.1 A
MCm 15/45
8.5 A
8.5 A
–
MC 15/45
6.1 A
3.5 A
6.1 A
3.5 A
PALLETIZATION MODEL
GROUPAGE
CONTAINER kg
kg
n° pumps
H (mm)
1~
3~
n° pumps
H (mm)
1~
3~
MC 10/45
45
1400
953
881
60
1820
1265
1169
MC 15/45
45
1574
1085
998
60
2052
1441
1325
Single-phase
Three-phase
MCm 10/45 MCm 15/45
H
0
80
00
12
311
VXC "VORTEX" Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 1200 l/min (72 m3/h) •• Head up to 16 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
INSTALLATION AND USE VXC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a VORTEX impeller and are therefore suitable for draining waste water, sewage, water mixed with mud and sludge. They are ideal for use in sewage installations, tunnels, excavations, canals and underground car parks, etc.
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: ••
– up to Ø 50 mm for VXC 15-20-30/50 – up to Ø 70 mm for VXC 15-20-30/70 Minimum immersion depth for continuous service: – 390 mm for VXC 15-20-30/50 – 430 mm for VXC 15-20-30/70
CONSTRUCTION AND SAFETY STANDARDS
•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
312
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0017
OPTIONALS AVAILABLE ON REQUEST
•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: single-phase three-phase – VXCm 30/50 - HP 3 – VXC 15-20-30/50 - HP 1.5-2-3 – VXCm 30/70 - HP 3 – VXC 15-20-30/70 - HP 1.5-2-3
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
VXC30/50
VXC20/50 VXC15/50
Head H (metres) 4
VXC30/70
VXC20/70
VXC15/70
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
VXCm 15/50
VXC 15/50
1.1
1.5
VXCm 20/50
VXC 20/50
1.5
2
VXCm 30/50
VXC 30/50
2.2
3
VXCm 15/70
VXC 15/70
1.1
1.5
VXCm 20/70
VXC 20/70
1.5
VXCm 30/70
VXC 30/70
2.2
Q = Flow rate H = Total manometric head
Q
m³/h
0
l/min
0
6
12
18
21
24
30
36
42
48
51
54
60
11.5 10.5 13
12
9.5
8.2
7.2
6.5
4.5
2
11
9.5
9
8
6.5
4.5
72
2
16
15
14
13
12.3 11.5
10
8
5.9
3.3
2
6.5
–
5.5
5
4.7
4.4
3.7
3
2.2
1.5
1
2
8.5
–
7.4
6.7
6.3
6
5.2
4.5
3.6
2.8
2.4
2
1
3
11
–
9.7
9
8.6
8.2
7.5
6.7
5.8
5
4.6
4.2
3.3
H metres
66
100 200 300 350 400 500 600 700 800 850 900 1000 1100 1200
2.5
1.5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
313
VXC "VORTEX" POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Cast iron VORTEX type
4
MOTOR CASING
Cast iron
5
MOTOR CASING PLATE
Cast iron
6
MOTOR SHAFT
Stainless steel AISI 431
7
TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
STA-20 STA-19
Ø 20 mm Ø 19 mm
8
BEARINGS
9
CAPACITOR
Motor side Pump side
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Silicon carbide
Graphite Silicon carbide
NBR NBR
6304 ZZ - C3 / 6304 ZZ - C3
Pump
Capacitance
Single-phase
(230 V or 240 V)
VXCm 15/50 VXCm 15/70 VXCm 20/50 VXCm 20/70 VXCm 30/50 VXCm 30/70 10
Position
8
31.5 μF 450 VL
6
50 μF 450 VL
11
10
60 μF 450 VL
4
ELECTRIC MOTOR VXCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding
8 5
➠ VXCm 30: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding to be connected to the control box.
7
➠ VXC: three-phase 400 V - 50 Hz. with thermal overload protector built-in to the winding to be connected to the control box. – Insulation: F class. – Protection: IP X8. 11
14
POWER CABLE 10 metre long “H07 RN-F” cable
12
1
CONTROL BOX for VXCm 15-20 (only for single-phase versions)
3
2
Complete with capacitor and manual reset motor protector 13
CONTROL BOX for VXCm 30 (only for single-phase versions)
Standard features
QES 300 MONO series 14
FLOAT SWITCH (only for single-phase versions)
Standard features
12
9
9
13
Control box for VXCm 15-20 (only for single-phase versions)
314
Control box for VXCm 30 (only for single-phase versions)
DIMENSIONS AND WEIGHT Typical installation
a
d
h1
e
p (minimum)
h
DN
b
MODEL
PORT
Single-phase
Three-phase
VXCm 15/50
VXC 15/50
VXCm 20/50
VXC 20/50
VXCm 30/50
VXC 30/50
VXCm 15/70
VXC 15/70
VXCm 20/70
VXC 20/70
VXCm 30/70
VXC 30/70
(minimum)
c
DIMENSIONS mm
DN
solids passage
a
b
c
2½”
Ø 50 mm
162
135
210
h 509
h1
d
191
75
522/509 3”
Ø 70 mm
180
150
548
237
kg e
p
variable 233
800
800
85
562/548
1~
3~
36.2
34.9
37.3
36.0
41.2
38.0
36.4
35.1
37.5
36.2
41.5
38.3
ABSORPTION MODEL
MODEL
VOLTAGE (single-phase)
VOLTAGE (three-phase)
Single-phase
230 V
240 V
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
VXCm 15/50
8.8 A
8.8 A
VXC 15/50
5.9 A
3.4 A
2.0 A
5.9 A
3.4 A
2.0 A
VXCm 20/50
10.2 A
10.2 A
VXC 20/50
7.3 A
4.2 A
2.4 A
7.3 A
4.2 A
2.4 A
VXCm 30/50
15.6 A
15.6 A
VXC 30/50
9.9 A
5.7 A
3.3 A
9.9 A
5.7 A
3.3 A
VXCm 15/70
8.7 A
8.7 A
VXC 15/70
5.7 A
3.3 A
1.9 A
5.7 A
3.3 A
1.9 A
VXCm 20/70
10.0 A
10.0 A
VXC 20/70
7.3 A
4.2 A
2.4 A
7.3 A
4.2 A
2.4 A
VXCm 30/70
15.0 A
15.0 A
VXC 30/70
9.5 A
5.5 A
3.2 A
9.5 A
5.5 A
3.2 A
PALLETIZATION MODEL
GROUPAGE / CONTAINER kg
n° pumps
H (mm)
VXC 15/50
24
1751
887
855
VXC 20/50
24
1751
913
882
VXCm 30/50
VXC 30/50
24
1751
1007
930
VXCm 15/70
VXC 15/70
12
1304
454
438
VXCm 20/70
VXC 20/70
12
1304
467
451
VXCm 30/70
VXC 30/70
12
1304
515
477
Single-phase
Three-phase
VXCm 15/50 VXCm 20/50
1~
3~ H
0 80
00
12
315
MC
"DOUBLE-CHANNEL"
Submersible pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 1600 l/min (96 m3/h) •• Head up to 25 m
APPLICATION LIMITS
•• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: ••
– up to Ø 50 mm for MC 15-20-30-40/50 – up to Ø 70 mm for MC 30-40/70 Minimum immersion depth for continuous service: – 390 mm for MC 15-20-30-40/50 – 430 mm for MC 30-40/70
INSTALLATION AND USE MC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a DOUBLE-CHANNEL impeller and are capable of pumping liquids containing short fibred suspended solids. They are ideal for pumping sewage, waste water, water mixed with mud, groundwater and surface water in locations such as apartment blocks, public buildings, factories, tower garages, underground car parks and cleaning areas, etc.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0017
OPTIONALS AVAILABLE ON REQUEST
CONSTRUCTION AND SAFETY STANDARDS
•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
•• Complete with 10 m long power cable •• Float switch for single-phase versions
GUARANTEE
EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
316
1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: single-phase three-phase – MCm 30/50 - HP 3 – MC 15-20-30-40/50 - HP 1.5-2-3-4 – MCm 30/70 - HP 3 – MC 30-40/70 - HP 3-4
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min US g.p.m. Imp g.p.m.
25
MC40/50
feet
MC30/50 70
20
Head H (metres) 4
60 MC20/50
15
50
MC15/50
40
10
30
20
5 MC40/70
10
MC30/70
0
0
200
400
600
800
1000
1200
1400
1600
l/min m³/h
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
0
m³/h
0
6
12
18
24
30
36
42
48
l/min
0
100
200
300
400
500
600
700
800
12.5 10.5
8.5
6.5
4.5
3
1
12.5 10.5
8.5
6.5
5
3
54
60
66
72
84
96
900 1000 1100 1200 1400 1600
MCm 15/50
MC 15/50
1.1
1.5
16
14
MCm 20/50
MC 20/50
1.5
2
18
16
MCm 30/50
MC 30/50
2.2
3
24
22
20
18
16
14
12
10
8
6
4
2
–
MC 40/50
3
4
25
24
22
20
18
16
14
12
10
8
6
4
MCm 30/70
MC 30/70
2.2
3
13
–
12
11
10.5
9.5
8.5
8
7.5
6.5
6
5
4.5
3
2
–
MC 40/70
3
4
17
–
15
14
13.5 12.5
12
11
10.5
9.5
8.5
8
7
5.5
4
Q = Flow rate H = Total manometric head
H metres
14
1
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
317
MC
"DOUBLE-CHANNEL"
POS. COMPONENT
CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, with threaded port in compliance with ISO 228/1
2
BASE
Stainless steel AISI 304
3
IMPELLER
Stainless steel AISI 304 DOUBLE-CHANNEL type
4
MOTOR CASING
Cast iron
5
MOTOR CASING PLATE
Cast iron
6
MOTOR SHAFT
Stainless steel AISI 431
7
TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal
Shaft
Model
Diameter
STA-20 STA-19
Ø 20 mm Ø 19 mm
8
BEARINGS
9
CAPACITOR
10
Position Motor side Pump side
Materials Stationary ring
Rotational ring
Elastomer
Ceramic Silicon carbide
Graphite Silicon carbide
NBR NBR
6304 ZZ - C3 / 6304 ZZ - C3
Pump
Capacitance
Single-phase
(230 V or 240 V)
MCm 15/50 MCm 20/50 MCm 30/50 MCm 30/70
31.5 μF 450 VL 50 μF 450 VL
8 6
60 μF 450 VL
11
10
ELECTRIC MOTOR
4
MCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding
8
➠ MCm 30: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding to be connected to the control box
5 7
➠ MC: three-phase 400 V - 50 Hz. with thermal overload protector built-in to the winding to be connected to the control box – Insulation: F class – Protection: IP X8 11
POWER CABLE 14
10 metre long “H07 RN-F” cable 12
CONTROL BOX for MCm 15-20 (only for single-phase versions)
1
Complete with capacitor and manual reset motor protector 13
3
2
CONTROL BOX for MCm 30 (only for single-phase versions) QES 300 MONO series
14
Standard features
FLOAT SWITCH (only for single-phase versions)
Standard features
12
9
9
13
Control box for MCm 15-20 (only for single-phase versions)
318
Control box for MCm 30 (only for single-phase versions)
DIMENSIONS AND WEIGHT Typical installation
a
d
h1
e
p (minimum)
h
DN
b
MODEL
PORT
Single-phase Three-phase
DN
MCm 15/50
MC 15/50
MCm 20/50
MC 20/50
MCm 30/50
MC 30/50
–
MC 40/50
MCm 30/70
MC 30/70
–
MC 40/70
(minimum)
c
solids passage
DIMENSIONS mm a
b
c
h
h1
kg
d
e
1~
p
509 2½”
Ø 50 mm
162
135
210
522/509
191
75 variable
522 3”
Ø 70 mm
180
150
237
562/548 562
233
800
800
85
3~
36.7
35.4
37.7
36.4
41.9
38.6
–
42.2
45.0
41.7
–
45.3
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
240 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
MCm 15/50
9.0 A
9.0 A
MC 15/50
5.5 A
3.2 A
1.8 A
5.5 A
3.2 A
1.8 A
MCm 20/50
10.5 A
10.5 A
MC 20/50
7.4 A
4.3 A
2.5 A
7.4 A
4.3 A
2.5 A
MCm 30/50
15.2 A
15.2 A
MC 30/50
9.9 A
5.7 A
3.3 A
9.9 A
5.7 A
3.3 A
MCm 30/70
15.2 A
15.2 A
MC 40/50
13.5 A
7.8 A
4.5 A
13.5 A
7.8 A
4.5 A
MC 30/70
10.2 A
5.9 A
3.4 A
10.2 A
5.9 A
3.4 A
MC 40/70
13.5 A
7.8 A
4.5 A
13.5 A
7.8 A
4.5 A
PALLETIZATION MODEL Single-phase
Three-phase
GROUPAGE / CONTAINER n° pumps
H (mm)
kg 1~
3~
MCm 15/50
MC 15/50
24
1751
899
867
MCm 20/50
MC 20/50
24
1751
923
891
24
1751
1023
944
24
1751
–
1031
MCm 30/70
MC 30/70
12
1304
557
517
–
MC 40/70
12
1304
–
561
0
MC 30/50 MC 40/50
80
MCm 30/50 –
H
00
12
319
PVXC "VORTEX" Fixed installation pumps ➠ for sewage water
PERFORMANCE RANGE
•• Flow rate up to 1200 l/min (72 m3/h) •• Head up to 16 m
INSTALLATION AND USE
•• 10 m maximum immersion depth
PVXC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a VORTEX impeller and are therefore suitable for draining waste water, water mixed with mud, liquids containing air or gas, as well as sludge. They are suitable for use in fixed sewer, tunnel, well and underground car park installations.
•• Maximum liquid temperature +40 °C •• Solids passage:
PATENTS - TRADE MARKS - MODELS
APPLICATION LIMITS
(with a sufficiently long power cable)
••
– up to Ø 50 mm for PVXC 15-20-30/50 – up to Ø 70 mm for PVXC 15-20-30/70 Minimum immersion depth for continuous service: – 390 mm for PVXC 15-20-30/50 – 440 mm for PVXC 15-20-30/70
CONSTRUCTION AND SAFETY STANDARDS
•• Standard features: base pedestal, threaded delivery counterflange, guide tube supports (the guide tubes are not included)
•• 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
320
•• Registered Community Design n° 342159-0017
OPTIONALS AVAILABLE ON REQUEST
•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: three-phase single-phase – PVXCm 30/50 - HP 3 – PVXC 15-20-30/50 - HP 1.5-2-3 – PVXCm 30/70 - HP 3 – PVXC 15-20-30/70 - HP 1.5-2-3
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min
PVXC30/50
PVXC20/50
Head H (metres) 4
PVXC15/50 PVXC30/70
PVXC20/70
PVXC15/70
Flow rate Q 4
MODEL Single-phase
Three-phase
POWER kW
HP
PVXCm 15/50
PVXC 15/50
1.1
1.5
PVXCm 20/50
PVXC 20/50
1.5
2
PVXCm 30/50
PVXC 30/50
2.2
3
PVXCm 15/70
PVXC 15/70
1.1
1.5
PVXCm 20/70
PVXC 20/70
1.5
PVXCm 30/70
PVXC 30/70
2.2
Q = Flow rate H = Total manometric head
Q
m³/h
0
l/min
0
6
12
18
21
24
27
11.5 10.5 9.5 13
12
36
8.2
7.2
6.5
5.6
4.5
2
11
9.5
9
8
7.2
6.5
4.5
16
15
14
13
12.3 11.5 10.8
6.5
–
5.5
5
4.7
2
8.5
–
7.4
6.7
3
11
–
9.7
9
H metres
30
42
48
51
54
60
66
72
100 200 300 350 400 450 500 600 700 800 850 900 1000 1100 1200 2
10
8
5.9
3.3
2
4.4
4
3.7
3
2.2
1.5
1
6.3
6
5.6
5.2
4.5
3.6
2.8
2.4
2
1
8.6
8.2
7.8
7.5
6.7
5.8
5
4.6
4.2
3.3
2.5
1.5
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
321
PVXC "VORTEX" POS. CONSTRUCTION CHARACTERISTICS
POS. CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with flanged ports
2
SUCTION PLATE
Cast iron
3
BASE PEDESTAL
Cast iron
4
CONTERFLANGE
Steel, complete with threaded ports in compliance with ISO 228/1
GUIDE TUBE SUPPORTS
Cast iron
6
IMPELLER
Cast iron VORTEX type
7
MOTOR CASING
Cast iron
8
MOTOR CASING PLATE
Cast iron
9
MOTOR SHAFT
Stainless steel AISI 431
Shaft Diameter
STA-20
Ø 20 mm
STA-19
(230 V or 240 V)
PVXCm 15/50-70 PVXCm 20/50-70 PVXCm 30/50-70
31.5 μF 450 VL 50 μF 450 VL 60 μF 450 VL
13 ELECTRIC MOTOR
➠ PVXC: three-phase 400 V - 50 Hz with motor protector built-in to the winding to be connected to the control box – Insulation: F class
Materials Stationary ring Rotational ring
Ceramic Graphite Silicon carbi-Silicon carbiØ 19 mm de de
11 BEARINGS
Capacitance
Single-phase
➠ PVXCm 30: single-phase 230 V - 50 Hz with motor protector built-in to the winding to be connected to the control box
10 TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER
Model
Pump
PVXCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding.
5
Seal
12 CAPACITOR
Elastomer
NBR NBR
6304 ZZ - C3 / 6304 ZZ - C3
– Protection: IP X8
14 POWER CABLE
10 m long “H07 RN-F” cable
15 CONTROL BOX for PVXCm 15-20 (only for single-phase versions)
Complete with capacitor and manual reset motor protector
16 CONTROL BOX for PVXCm 30 (only for single-phase versions)
QES 300 MONO series
17 FLOAT SWITCH
Standard features 15
5 11 9
12
7
14
13 4
5
Control box for PVXCm 15-20 (HP 1.5-2.0) (only for single-phase versions)
11 10
8
Standard features
17
3
1
2
6
12
16
Control box for PVXCm 30 (HP 3.0)
(only for single-phase versions)
322
DIMENSIONS AND WEIGHT Typical installation
a
Guide tubes Ø external 27 mm maximum Ø internal 19.5÷21.5 mm w DN
h
b
g
m
d
c
e
f
n
MODEL
PORT
Single-phase
Three-phase
PVXCm 15/50
PVXC 15/50
PVXCm 20/50
PVXC 20/50
PVXCm 30/50
PVXC 30/50
PVXCm 15/70
PVXC 15/70
PVXCm 20/70
PVXC 20/70
PVXCm 30/70
PVXC 30/70
DN 2½”
solids passage
DIMENSIONS mm a
Ø 50 mm
b 116
c 51
d
e
490
62
f 248
g 52
Ø 70 mm
h
m
442
198
n
w
120
72
457 / 442
60 3”
kg*
150
70
570
85
268
458
92
255
130
112
472 / 458
1~
3~
47.3
46.0
48.4
47.1
52.3
49.2
54.0
52.7
55.1
53.8
59.1
55.9
(*weight includes counterflanges)
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
240 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
PVXCm 15/50
8.8 A
8.8 A
PVXC 15/50
5.9 A
3.4 A
2.0 A
5.9 A
3.4 A
2.0 A
PVXCm 20/50
10.2 A
10.2 A
PVXC 20/50
7.3 A
4.2 A
2.4 A
7.3 A
4.2 A
2.4 A 3.3 A
PVXCm 30/50
15.6 A
15.6 A
PVXC 30/50
9.9 A
5.7 A
3.3 A
9.9 A
5.7 A
PVXCm 15/70
8.7 A
8.7 A
PVXC 15/70
5.7 A
3.3 A
1.9 A
5.7 A
3.3 A
1.9 A
PVXCm 20/70
10.0 A
10.0 A
PVXC 20/70
7.3 A
4.2 A
2.4 A
7.3 A
4.2 A
2.4 A
PVXCm 30/70
15.0 A
15.0 A
PVXC 30/70
9.5 A
5.5 A
3.2 A
9.5 A
5.5 A
3.2 A
PALLETIZATION MODEL
GROUPAGE / CONTAINER
Single-phase
Three-phase
n° pumps
H (mm)
PVXCm 15/50
PVXC 15/50
24
PVXCm 20/50
PVXC 20/50
24
kg 1~
3~
1751
1153
1122
1751
1179
1148 1197
24
1751
1273
12
1304
665
650
PVXCm 20/70
PVXC 20/70
12
1304
679
663
PVXCm 30/70
PVXC 30/70
12
1304
727
688
0
PVXC 30/50 PVXC 15/70
80
PVXCm 30/50 PVXCm 15/70
H
00
12
323
PMC
"DOUBLE-CHANNEL"
Fixed installation pumps ➠ for sewage water
PERFORMANCE RANGE
INSTALLATION AND USE
APPLICATION LIMITS
PMC pumps, made from heavy gauge cast iron offering exceptional sturdiness and abrasion resistance, come equipped with a DOUBLE-CHANNEL stainless steel impeller and are capable of pumping liquids containing short fibred suspended solids. They are ideal for pumping sewage, waste water, water mixed with mud, groundwater and surface water in locations such as apartment blocks, public buildings, factories, tower garages, underground car parks and cleaning areas, etc.
•• Flow rate up to 1600 l/min (96 m3/h) •• Head up to 25 m •• 10 m maximum immersion depth
(with a sufficiently long power cable)
•• Maximum liquid temperature +40 °C •• Solids passage: ••
– up to Ø 50 mm for PMC 15-20-30-40/50 – up to Ø 70 mm for PMC 30-40/70 Minimum immersion depth for continuous service: – 390 mm for PMC 15-20-30-40/50 – 440 mm for PMC 30-40/70
CONSTRUCTION AND SAFETY STANDARDS
•• Standard features: base pedestal, threaded delivery counterflange, guide tube supports (the guide tubes are not included)
•• 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
324
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 342159-0017
OPTIONALS AVAILABLE ON REQUEST
•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: single-phase three-phase – PMCm 30/50 - HP 3 – PMC 15-20-30-40/50 - HP 1.5-2-3-4 – PMCm 30/70 - HP 3 – PMC 30-40/70 - HP 3-4
CHARACTERISTIC CURVES AND PERFORMANCE DATA
50 Hz n= 2900 1/min US g.p.m.
25
Imp g.p.m. PMC40/50
feet
PMC30/50 70
20
Head H (metres) 4
60 PMC20/50
15
50
PMC15/50
40
10
30
20
5 PMC40/70
10
PMC30/70
0
0
200
400
600
800
1000
1200
1400
1600
l/min m³/h
Flow rate Q 4
MODEL Single-phase Three-phase
POWER kW
HP
Q
0
m³/h
0
6
12
18
24
30
36
42
48
l/min
0
100
200
300
400
500
600
700
800
12.5 10.5
8.5
6.5
4.5
3
1
12.5 10.5
8.5
6.5
5
3
54
60
66
72
84
96
900 1000 1100 1200 1400 1600
PMCm 15/50
PMC 15/50
1.1
1.5
16
14
PMCm 20/50
PMC 20/50
1.5
2
18
16
PMCm 30/50
PMC 30/50
2.2
3
24
22
20
18
16
14
12
10
8
6
4
2
–
PMC 40/50
3
4
25
24
22
20
18
16
14
12
10
8
6
4
PMCm 30/70
PMC 30/70
2.2
3
13
–
12
11
10.5
9.5
8.5
8
7.5
6.5
6
5
4.5
3
2
–
PMC 40/70
3
4
17
–
15
14
13.5 12.5
12
11
10.5
9.5
8.5
8
7
5.5
4
Q = Flow rate H = Total manometric head
H metres
14
1
Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.
325
PMC
"DOUBLE-CHANNEL"
POS. CONSTRUCTION CHARACTERISTICS
POS. CONSTRUCTION CHARACTERISTICS
1
PUMP BODY
Cast iron, complete with flanged ports
2
SUCTION PLATE
Cast iron
3
BASE PEDESTAL
Cast iron
4
CONTERFLANGE
Steel, complete with threaded ports in compliance with ISO 228/1
GUIDE TUBE SUPPORTS
Cast iron
6
IMPELLER
Stainless steel AISI 304 DOUBLE-CHANNEL type
7
MOTOR CASING
Cast iron
8
MOTOR CASING PLATE
Cast iron
9
MOTOR SHAFT
Stainless steel AISI 431
Shaft Diameter
STA-20
Ø 20 mm
STA-19
(230 V or 240 V)
PMCm 15/50 PMCm 20/50 PMCm 30/50-70
31.5 μF 450 VL 50 μF 450 VL 60 μF 450 VL
13 ELECTRIC MOTOR
➠ PMC: three-phase 400 V - 50 Hz with motor protector builtin to the winding to be connected to the control box – Insulation: F class
Materials Stationary ring Rotational ring
Ceramic Graphite Silicon carbi-Silicon carbiØ 19 mm de de
11 BEARINGS
Capacitance
Single-phase
➠ PMCm 30: single-phase 230 V - 50 Hz with motor protector built-in to the winding to be connected to the control box
10 TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER
Model
Pump
PMCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding.
5
Seal
12 CAPACITOR
Elastomer
NBR NBR
– Protection: IP X8
14 POWER CABLE
10 m long “H07 RN-F” cable
15 CONTROL BOX foe PMCm 15-20 (only for single-phase versions)
Complete with capacitor and manual reset motor protector
16 CONTROL BOX for PMCm 30 (only for single-phase versions)
QES 300 MONO series
17 FLOAT SWITCH
6304 ZZ - C3 / 6304 ZZ - C3
Standard features
15
5 11 9
12
7
14
13 4
5
Control box for PMCm 15-20 (HP 1.5-2.0) (only for single-phase versions)
11 10
8
Standard features
17
3
1
2
6
12
16
Control box for PMCm 30 (HP 3.0)
(only for single-phase versions)
326
DIMENSIONS AND WEIGHT Typical installation
a
Guide tubes Ø external 27 mm maximum Ø internal 19.5÷21.5 mm w DN
h
b
g
m
d
c
e
f
n
MODEL
PORT
Single-phase
Three-phase
PMCm 15/50
PMC 15/50
PMCm 20/50
PMC 20/50
PMCm 30/50
PMC 30/50
–
PMC 40/50
PMCm 30/70
PMC 30/70
–
PMC 40/70
DN
solids passage
DIMENSIONS mm a
b
c
d
e
f
kg*
g
h
m
n
w
442 2½”
Ø 50 mm
116
51
490
62
248
52
60 3”
Ø 70 mm
198
457 / 442
120
72
1~
3~
47.2
45.9
48.2
46.9
52.2
49.1
–
52.7
457 150
70
570
85
268
92
472 / 458
255
472
130
112
62.6
59.3
–
62.9
(*weight includes counterflanges)
ABSORPTION MODEL
VOLTAGE (single-phase)
Single-phase
230 V
MODEL
240 V
VOLTAGE (three-phase)
Three-phase
230 V
400 V
690 V
240 V
415 V
720 V
PMCm 15/50
9.0 A
9.0 A
PMC 15/50
6.1 A
3.5 A
2A
6.1 A
3.5 A
2.0 A
PMCm 20/50
10.5 A
10.5 A
PMC 20/50
7.4 A
4.3 A
2.5 A
7.4 A
4.3 A
2.5 A
PMCm 30/50
15.2 A
15.2 A
PMC 30/50
9.9 A
5.7 A
3.3 A
9.9 A
5.7 A
3.3 A
PMCm 30/70
15.2 A
15.2 A
PMC 40/50
13.5 A
7.8 A
4.5 A
13.5 A
7.8 A
4.5 A
PMC 30/70
10.2 A
5.9 A
3.4 A
10.2 A
5.9 A
3.4 A
PMC 40/70
13.5 A
7.8 A
4.5 A
13.5 A
7.8 A
4.5 A
PALLETIZATION MODEL
GROUPAGE / CONTAINER kg
n° pumps
H (mm)
PMC 15/50
24
1751
PMCm 20/50
PMC 20/50
24
1751
1175
1143
PMCm 30/50
PMC 30/50
24
1751
1275
1196 1283
Single-phase
Three-phase
PMCm 15/50
1~
3~
1151
1119
12
1751
–
12
1304
769
729
–
PMC 30/70
12
1304
–
772
0
PMC 40/50 PMC 30/70
80
– PMCm 30/70
H
00
12
327
SAR
Storage and lifting stations
PERFORMANCE RANGE 0
45
20
0
50 Hz n= 2900 1/min 40
60
20
40
80
100
60
120
80
140
100
160
120
180 140
200 160
220 US g.p.m. 180
Imp g.p.m. feet 140
CLEAR WASTE WATER - RAINWATER 40
130 120
35
110 100
Head H (metres) 4
30
90
25
80 70
20
60 50
15
40
10
30 20
5 SAR 40
0
0
SAR 100
100
200
SAR 250 SAR 550
300
10
SAR 550 (2 PUMPS)
400
500
600
700
800
l/min 0
1
0 0
10
20
30
Flow rate Q 4
328
40
50
m³/h
0 1
PERFORMANCE RANGE 0
16
50 Hz n= 2900 1/min
50
0
100 50
150 100
200
250
150
300
200
350
250
US g.p.m.
400 300
Imp g.p.m.
350
feet 50
DIRTY WASTE WATER
15 14 13
40
12
Head H (metres) 4
11 10 30
9 8 7
20
6 5 4
10
3 2 1 0
SAR 40
0 0
SAR 100
200 10
SAR 250 SAR 550
400 20
SAR 550 (2 PUMPS)
600 30
800 40
50
1000 60
1200 70
1400 80
1600 90
l/min 100
0
m³/h
Flow rate Q 4
329
SAR 40 CLEAR WASTE WATER - RAINWATER MODEL
POWER kW
HP
TANK CAPACITY litres
MAXIMUM FLOW RATE l/min
MAXIMUM HEAD metres
SAR 40 - TOP 1
0.25
0.33
40
160
6
SAR 40 - TOP 2
0.37
0.50
40
220
8
SAR 40 - TOP 3
0.55
0.75
40
260
10
SAR 40 - RXm 1
0.25
0.33
40
160
6.5
SAR 40 - RXm 2
0.37
0.50
40
220
9.5
SAR 40 - RXm 3
0.55
0.75
40
220
11.5
COMPONENTS
•• 40-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 5 metres standard issue with Schuko plug •• Non-return valve
DIRTY WASTE WATER MODEL
POWER kW
HP
TANK CAPACITY litres
MAXIMUM FLOW RATE l/min
MAXIMUM HEAD metres
SAR 40 - TOP VORTEX
0.37 0.50
40
180
6.5
SAR 40 - RXm2/20
0.37 0.50
40
180
6.5
COMPONENTS
•• 40-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 5 metres standard issue with Schuko plug •• Non-return valve
OPTIONALS AVAILABLE ON REQUEST
•• Pump with 10 m long power cable.
➠ Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications
330
SAR 100 CLEAR WASTE WATER - RAINWATER MODEL
SAR 100 - TOP 2 SAR 100 - TOP 3 SAR 100 - TOP 4 SAR 100 - TOP MULTI 2 SAR 100 - TOP MULTI 3 SAR 100 - RXm 2 SAR 100 - RXm 3 SAR 100 - Dm 10 SAR 100 - Dm 15 SAR 100 - Dm 20 SAR 100 - Dm 30
POWER kW
HP
TANK CAPACITY litres
MAXIMUM FLOW RATE l/min
MAXIMUM HEAD metres
0.37
0.50
100
220
8
0.55
0.75
100
260
10
0.75
1
100
320
12
0.55
0.75
100
80
40
0.55
0.75
100
120
32
0.37
0.50
100
220
9.5
0.55
0.75
100
220
11.5
0.75
1
100
325
14.5
1.1
1.5
100
400
22
0.75
1
100
200
20
1.1
1.5
100
300
26
MAXIMUM FLOW RATE l/min
MAXIMUM HEAD metres
COMPONENTS
•• 100-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 10 m (standard issue with Schuko plug)
DIRTY WASTE WATER MODEL
SAR 100 - TOP-VORTEX SAR 100 - RXm 2/20 SAR 100 - RXm 3/20 SAR 100 - ZXm 1A/40 SAR 100 - VXm 8/35 SAR 100 - VXm 10/35 SAR 100 - VXm 8/50 SAR 100 - VXm 10/50 SAR 100 - MCm 10/50
POWER kW
HP
TANK CAPACITY litres
0.37
0.50
100
180
6.5
0.37
0.50
100
180
6.5
0.55
0.75
100
180
8
0.60
0.85
100
400
10.5
0.55
0.75
100
250
7.5
0.75
1
100
300
9.5
0.55
0.75
100
350
5.5
0.75
1
100
400
7
0.75
1
100
500
10.7
COMPONENTS
•• 100-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 10 m (standard issue with Schuko plug)
331
SAR 250 CLEAR WASTE WATER - RAINWATER MODEL
SAR 250 - TOP 3 SAR 250 - TOP 4 SAR 250 - TOP 5 SAR 250 - RXm 3 SAR 250 - RXm 4 SAR 250 - RXm 5 SAR 250 - Dm 10 SAR 250 - Dm 15 SAR 250 - Dm 20 SAR 250 - Dm 30
POWER
TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD litres l/min metres
kW
HP
0.55
0.75
250
260
0.75
1
250
320
12
0.92
1.25
250
400
14
0.55
0.75
250
220
11.5
0.75
1
250
260
15
10
1.1
1.5
250
300
19.5
0.75
1
250
325
14.5
1.1
1.5
250
400
22
0.75
1
250
200
20
1.1
1.5
250
300
26
DIRTY WASTE WATER MODEL
SAR 250 - TOP-VORTEX SAR 250 - RXm 3/20 SAR 250 - RXm 4/40 SAR 250 - RXm 5/40 SAR 250 - VXm10/35-I SAR 250 - VXm10/50-I SAR 250 - MCm10/50-I SAR 250 - VXm 10/35 SAR 250 - VXm 15/35 SAR 250 - VXm 10/50 SAR 250 - VXm 15/50 SAR 250 - MCm 10/50 SAR 250 - MCm 12/50
POWER
TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD litres l/min metres
kW
HP
0.37
0.50
250
180
0.55
0.75
250
180
8
0.75
1
250
280
9.5
6.5
1.1
1.5
250
380
12.5
0.75
1
250
300
9.5
0.75
1
250
400
7
0.75
1
250
500
10.7
0.75
1
250
300
9.5
1.1
1.5
250
450
14
0.75
1
250
400
7
1.1
1.5
250
500
10.5
0.75
1
250
500
10.7
1.1
1.5
250
800
14
COMPONENTS
•• 250-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 10 m (standard issue with Schuko plug) •• Lowering device (only for VX-I and MC-I versions)
BASE PEDESTAL ELBOW (DUCT FOOT) MODEL PA/1 (VX /35-I) PA/2 (VX /50-I and MC /50-I)
PORTS DN1 1 ½" 2"
DN2 2"
OPTIONALS AVAILABLE ON REQUEST Alarm KIT Kit includes: •• Float switch, Self-powered siren, Control box 300 mm extension kit Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths
DN1
332
DN2
300 mm extension kit for VX-I and MC-I versions Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths •• Longer lowering device
SAR 550 CLEAR WASTE WATER - RAINWATER MODEL
POWER kW
HP
SAR 550 - TOP4
0.75
1
SAR 550 - TOP5
TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD (1 pump) litres metres litri/min 550
320
12
0.92 1.25
550
400
14
SAR 550 - RXm4
0.75
1
550
260
15
SAR 550 - RXm5
1.1
1.5
550
300
19.5
SAR 550 - Dm10
0.75
1
550
325
14.5
SAR 550 - Dm15
1.1
1.5
550
400
22
SAR 550 - Dm20
0.75
1
550
200
20
SAR 550 - Dm30
1.1
1.5
550
300
26
DIRTY WASTE WATER MODEL
POWER kW
HP
SAR 550 - RXm 4/40
0.75
1
SAR 550 - RXm 5/40
1.1
1.5
TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD (1 pump) litres metres litri/min 550 280 9.5 550
380
12.5
SAR 550 - VXm 10/35-I 0.75
1
550
300
9.5
SAR 550 - VXm 10/50-I 0.75
1
550
400
7
SAR 550 - MCm10/50-I
0.75
1
550
500
10.7
SAR 550 - VXm 10/35
0.75
1
550
300
9.5
SAR 550 - VXm 15/35
1.1
1.5
550
450
14
SAR 550 - VXm 10/50
0.75
1
550
400
7
SAR 550 - VXm 15/50
1.1
1.5
550
500
10.5
SAR 550 - MCm 10/50
0.75
1
550
500
10.7
SAR 550 - MCm 12/50
1.1
1.5
550
800
14
COMPONENTS
•• 550-litre polyethylene tank with cover plate •• Two single-phase pumps •• Power cable: 10 m (standard issue with Schuko plug) •• Control panel •• Three float switches for: 1) the alternate start-up of one of the two pumps, ••
BASE PEDESTAL ELBOW (DUCT FOOT) MODEL PA/1 (VX /35-I) PA/2 (VX /50-I and MC /50-I)
PORTS DN1 1 ½" 2"
DN2 2"
2) maximum level for starting-up the second pump, 3) minimum level for switching the pumps off Lowering device (only for VX-I and MC-I versions)
OPTIONALS AVAILABLE ON REQUEST Alarm KIT Kit includes: •• Float switch, Self-powered siren, Control box 300 mm extension kit Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths
DN1
DN2
300 mm extension kit for VX-I and MC-I versions Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths •• Longer lowering device
333
SAR DIMENSIONS AND WEIGHT MODEL
PORTS I
h I i1
i1
S
b
I
16.1 1½"
410
410
60
14.2 15.3
14.6
SAR 40 - RXm 2/20
15.6
PORTS U
DIMENSIONS mm S
a
b
h
i1
kg i2 28.7
1¼"
30.1 33.6
1½"
SAR 100 - TOP MULTI 2
32.9
SAR 100 - TOP MULTI 3
32.9
1¼"
SAR 100 - RXm2
29.3
SAR 100 - RXm3
29.6
SAR 100 - Dm10
36.2
SAR 100 - Dm15 SAR 100 - Dm20 SAR 100 - Dm30
Ø 110 mm
1½"
SAR 100 - TOP-VORTEX SAR 100 - RXm 2/20
37.9 Ø 50 mm
500 690 645 145 100
36.5 38.5 28.6
1¼"
29.6
SAR 100 - RXm 3/20
29.8
SAR 100 - ZXm 1A/40
35.2
SAR 100 - VXm 8/35
1½"
35.9
SAR 100 - VXm 10/35
36.8
SAR 100 - VXm 8/50
36.4
SAR 100 - VXm 10/50 SAR 100 - MCm 10/50
334
310
SAR 40 - TOP-VORTEX
SAR 100 - TOP4
b
½"
16.9
SAR 100 - TOP3
a
1¼"
SAR 40 - RXm3
SAR 100 - TOP2
i2
kg i1
SAR 40 - TOP3
I
i1
h
14.7
S
h
b
SAR 40 - TOP2
MODEL U
a
14.0
SAR 40 - RXm2
a
DIMENSIONS mm S
SAR 40 - TOP1
SAR 40 - RXm1
U
U
2"
37.4 37.6
DIMENSIONS AND WEIGHT MODEL
PORTS I
Extension kit
SAR 250 - TOP3
DIMENSIONS mm S
a
b
h
i1
kg i2 42.6
1¼"
SAR 250 - TOP4 300 mm
U
46.1
1½"
SAR 250 - TOP5 SAR 250 - RXm3
47.1 43.4
1¼"
SAR 250 - RXm4 I U S
48.7
SAR 250 - RXm5
49.7
SAR 250 - Dm10
48.7
1½"
SAR 250 - Dm15
h
49.0
SAR 250 - Dm30
51.0
SAR 250 - TOP-VORTEX SAR 250 - RXm 3/20 SAR 250 - RXm 4/40
41.1
Ø 1¼" Ø 110 50 700 970 mm mm
SAR 250 - RXm 5/40
i1
50.7
SAR 250 - Dm20
715
250
130
49.0 50.0
1½"
SAR 250 - VXm10/35-I
i2
46.8
SAR 250 - VXm10/50-I a
46.6
2"
SAR 250 - MCm10/50-I b
SAR 250 - VXm 10/35
46.9 49.3
1½"
SAR 250 - VXm 15/35
52.3
SAR 250 - VXm 10/50
49.9
SAR 250 - VXm 15/50
53.0
2"
SAR 250 - MCm 10/50
50.1
SAR 250 - MCm 12/50
53.0
MODEL
Extension kit
PORTS I
300 mm I U S
U I
i3 i1
i1
i2
i3
98.4
SAR 550 - RXm5
100.4
SAR 550 - Dm10
98.4 1½"
102.4
SAR 550 - Dm20
99.0
SAR 550 - Dm30
103.0
SAR 550 - VXm 10/35-I
SAR 550 - VXm 10/35 SAR 550 - VXm 15/35 b
h
SAR 550 - RXm4
SAR 550 - MCm10/50-I
a
b
95.2
SAR 550 - VXm 10/50-I
i2
a
SAR 550 - TOP5
SAR 550 - RXm 5/40 h
i2
S
kg
93.2
SAR 550 - RXm 4/40 i1
U
DIMENSIONS mm
SAR 550 - TOP4
SAR 550 - Dm15
S
43.8
99.0 Ø 50 1350 970 715 250 130 240 101.0 mm 94.6
Ø 110 mm
2"
1½"
SAR 550 - MCm 10/50 SAR 550 - MCm 12/50
94.8 99.6 105.6 100.8
SAR 550 - VXm 10/50 SAR 550 - VXm 15/50
94.2
2"
107.0 101.2 107.0
335
BETTY Portable self-priming pumps
BETTY 60-65
BETTY 1X-2X-3X
BETTYNOX
PERFORMANCE RANGE
CONSTRUCTION AND SAFETY STANDARDS
•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 55 m
EN 60335-1 IEC 60335-1 CEI 61-150
APPLICATION LIMITS
•• Manometric suction lift up to 9 m •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
PERFORMANCE AND CONSTRUCTION CHARACTERISTICS MODEL
PUMP
BETTY 60 BETTY 65 BETTY 1X BETTY 2X BETTY 3X BETTYNOX 1 BETTYNOX 2 BETTYNOX 3
PKSm 60 PKSm 65 JSWm 1CX JSWm 1BX JSWm 1AX JCRm 1C JCRm 1B JCRm 1A
Q l/min 5÷40 5÷50 5÷50 5÷50 5÷50 5÷50 5÷50 5÷50
H metres 38÷5 50÷8 32÷13 36÷15 42÷19 32÷13 36÷15 42÷19
➠ The BETTY series portable pumps come complete with: – a handle – Ø 20 mm hose attachments – 1.5 m long power cable with Schuko plug
336
INSTALLATION AND USE Suitable for use in gardening, horticultural, cleaning and hobby activities, they are suitable for use with any liquid that is compatible with the materials from which they are made.
OPTIONALS AVAILABLE ON REQUEST
•• Other voltages or 60 Hz frequency
GUARANTEE 1 year subject to terms and conditions
DIMENSIONS AND WEIGHT
DN1
Ø2
n1
DN2
Ø1
MODEL h
h1
BETTY 60 BETTY 65
f
PORTS
DIMENSIONS mm
Single-phase DN1 DN2 Ø1 Ø2 1"
1"
f
h
h1
n
n1
20 20 270 273 267 220 160
kg 7.9 9.5
DN1
Ø2
n
DN2
h
h1 Ø1
MODEL
PORTS
DIMENSIONS mm
Single-phase DN1 DN2 Ø1 Ø2
f
f1
h
h1
n
10.0
BETTY 1X BETTY 2X
1"
1"
20 20 433 373 260 255 230 10.7 10.9
BETTY 3X n
MODEL
DN2
PORTS
DIMENSIONS mm
Single-phase DN1 DN2 Ø1 Ø2 h
h1 Ø1
DN1
Ø2
f
f1
f
f1
h
1”
1”
n
kg
20 20 399 339 270 260 198 8.0 9.2
BETTYNOX 3 f1
h1
7.9
BETTYNOX 1 BETTYNOX 2
f
kg
n
PALLETIZATION MODEL Single-phase
GROUPAGE n° pumps
CONTAINER
H (mm)
kg 1~
n° pumps
H (mm)
kg 1~
BETTY 60
30
1265
254
50
2015
412
BETTY 65
30
1265
302
50
2015
492
BETTY 1X
30
1265
317
50
2015
517
BETTY 2X
30
1265
338
50
2015
552
BETTY 3X
30
1265
344
50
2015
562
1265
254
50
2015
412
1265
257
50
2015
417
BETTYNOX 3
30
1265
293
50
2015
477
0
30 30
80
BETTYNOX 1 BETTYNOX 2
H
00
12
337
EASYPUMP Pumps with electronic pressure switch PUMPS WITH EASYPRESS 1 MODEL
POWER kW
HP
PKm 60 - EP 1
0.37
0.50
PKm 65 - EP 1
0.50
0.70
0.75
1
3CPm 80-C - EP 1
0.45
0.60
4CPm 80-C - EP 1
0.60
0.85
3CPm 100 - C - EP 1
0.60
0.85
4CPm 100 - C - EP 1
0.75
1
Single-phase PK series pumps
2CP series pumps 2CPm 25/130 N - EP 1 3÷4CP series pumps
JSW series pumps JSWm 1 B
- EP 1
0.50
0.70
JSWm 1 A
- EP 1
0.60
0.85
JSWm 10 M - EP 1
0.75
1
JSWm 12 M - EP 1
0.90
1.25
JSWm 1 BX - EP 1
0.50
0.70
JSWm 1 AX - EP 1
0.60
0.85
JSWm 10 MX - EP 1
0.75
1
JSWm 12MX - EP 1
0.90
1.25
EASYPUMP - EP 1 COMPONENTS:
•• Single-phase pump •• EASYPRESS-1 with pressure gauge •• GSR quick-fit joint •• 1.5 meters power cable with Schuko plug EASYPUMP - EP 1 Small pumps fitted with an electronic pressure switch that starts and stops the pump as required when a tap is turned on or off. The pump is also protected against dry running.
338
PUMPS WITH EASYPRESS 2 MODEL
POWER kW
HP
1.1
1.5
JSWm 15M - EP 2
1.1
1.5
JSWm 15 MX - EP 2
1.1
1.5
Single-phase 2CP series pumps 2CPm 25/14B - EP 2 JSW series pumps
➠ EASYPRESS 2 for 1.5 HP pumps (1.1 kW)
EASYPUMP - EP 2 COMPONENTS:
•• Single-phase pump •• EASYPRESS-1 with pressure gauge •• GSR quick-fit joint •• 1.5 meters power cable with Schuko plug EASYPUMP - EP 2 Small pumps fitted with an electronic pressure switch that starts and stops the pump as required when a tap is turned on or off. The pump is also protected against dry running.
339
PRESSURE SETS WITH VESSEL
HYDROFRESH 5VT
HYDROFRESH 24 SF
HYDROFRESH 24 CL
HYDROFRESH 60 CL
PERFORMANCE MODEL
POWER
FLOW RATE (1)
SETTING (2)
kW
HP
l/min
bar
0.37 0.37 0.50 0.60
0.50 0.50 0.70 0.85
32 45 50 50
1.4 ÷ 2.8 1.2 ÷ 2.6 1.4 ÷ 2.8 1.8 ÷ 3.2
0.37 0.50 0.37 0.50 0.60 0.75 0.90 1.1
0.50 0.70 0.50 0.70 0.85 1 1.25 1.5
32 40 45 50 50 80 80 80
1.4 ÷ 2.8 1.5 ÷ 3.0 1.2 ÷ 2.6 1.4 ÷ 2.8 1.8 ÷ 3.2 1.4 ÷ 2.8 2.0 ÷ 3.5 2.5 ÷ 4.0
0.37 0.50 0.75 1.1 0.50 0.60 0.75 0.90 1.1 0.50 0.60 0.75 1.1
0.50 0.70 1 1.5 0.70 0.85 1 1.25 1.5 0.70 0.85 1 1.5
32 40 90 120 50 50 80 80 80 50 50 80 80
1.4 ÷ 2.8 1.5 ÷ 3.0 1.8 ÷ 3.2 2.2 ÷ 3.5 1.4 ÷ 2.8 1.8 ÷ 3.2 1.4 ÷ 2.8 2.0 ÷ 3.5 2.5 ÷ 4.0 1.4 ÷ 2.8 1.8 ÷ 3.2 1.4 ÷ 2.8 2.5 ÷ 4.0
0.75 0.90 1.1
1 1.25 1.5
80 80 80
1.4 ÷ 2.8 2.0 ÷ 3.5 2.5 ÷ 4.0
HYDROFRESH 5VT PKm 60 JSWm 1 CX JSWm 1 BX JSWm 1 AX
- 05 VT - 05 VT - 05 VT - 05 VT
HYDROFRESH 24 SF PKm 60 - 24 SF - 24 SF PKm 65 JSWm 1 CX - 24 SF JSWm 1 BX - 24 SF JSWm 1 AX - 24 SF JSWm 10 MX - 24 SF JSWm 12 MX - 24 SF JSWm 15 MX - 24 SF
HYDROFRESH 24 CL PKm 60 - 24 CL PKm 65 - 24 CL CPm 158 - 24 CL CPm 170 - 24 CL JSWm 1 BX - 24 CL JSWm 1 AX - 24 CL JSWm 10 MX - 24 CL JSWm 12 MX - 24 CL JSWm 15 MX - 24 CL JCRm 1 B - 24 CL JCRm 1 A - 24 CL JCRm 10 M - 24 CL JCRm 15 M - 24 CL
HYDROFRESH 60 CL JSWm 10 MX - 60 CL JSWm 12 MX - 60 CL JSWm 15 MX - 60 CL COMPONENTS: •• Single-phase pump •• Tank •• Pressure switch •• Pressure gauge (for 24SF, 24CL and 60CL)
340
•• Hose (for 24CL and 60CL) •• Brass connector •• 1.5 m power cable with Schuko plug
(1) Maximum flow rate at the minimum recommended pressure switch pressure (2) Recommended pressure range
DIMENSIONS AND WEIGHT MODEL
PORTS
a
l
DN2
DN1
h
PKm 60
- 05 VT
h DN2 DN1
h
DN1
a
210
kg
262
6.5
1"
1"
373
210
280
10.5
1"
373
210
280
11.2
JSWm 1 AX - 05 VT
1"
1"
373
210
280
11.5
PKm 60
- 24 SF
PKm 65
PORTS
DIMENSIONS mm l a h
DN1
DN2
1"
1"
360
390
522
WEIGHT kg 12.5
- 24 SF
1"
1"
373
390
530
13.9
JSWm 1 CX - 24 SF
1"
1"
437
390
551
16.5
JSWm 1 BX - 24 SF
1"
1"
437
390
551
17.3
JSWm 1 AX - 24 SF
1"
1"
437
390
551
17.6
JSWm 10 MX - 24 SF
1"
1"
463
390
572
21.0
JSWm 12 MX - 24 SF
1"
1"
463
390
572
22.0
JSWm 15 MX - 24 SF
1"
1"
463
390
572
22.4
PORTS
DIMENSIONS mm l a h
WEIGHT
DN1
DN2
PKm 60
- 24 CL
1"
1"
540
285
503
13.2
PKm 65
- 24 CL
1"
1"
540
285
508
14.8
CPm 158
- 24 CL
1"
1"
540
285
585
19.9
CPm 170
- 24 CL
1¼"
1"
540
285
605
26.3
JSWm 1 BX - 24 CL
1"
1"
540
295
486
17.9
JSWm 1 AX - 24 CL
1"
1"
540
295
486
18.2
JSWm 10 MX - 24 CL
1"
1"
540
345
507
21.6
JSWm 12 MX - 24 CL
1"
1"
540
345
507
22.6
JSWm 15 MX - 24 CL
1"
1"
540
345
507
23.0
JCRm 1 B
- 24 CL
1"
1"
540
285
519
14.3
JCRm 1 A
- 24 CL
1"
1"
540
285
519
14.8
JCRm 10 M - 24 CL
1¼"
1"
540
285
551
17.3
JCRm 15 M - 24 CL
1¼"
1"
540
285
551
18.4
MODEL DN2
JSWm 10 MX - 60 CL
PORTS DN1 1"
DN2 1"
DIMENSIONS mm l a h 750 400 647
kg
WEIGHT kg 28.2
JSWm 12 MX - 60 CL
1"
1"
750
400
647
29.2
JSWm 15 MX - 60 CL
1"
1"
750
400
647
29.6
h
DN1
255
1"
MODEL
l
1"
JSWm 1 CX - 05 VT
a
DN2
DN2
1"
WEIGHT
JSWm 1 BX - 05 VT
MODEL l
DN1
DIMENSIONS mm l a h
l
a
341
COMBIPRESS "CB2" Pressure boosting sets
CB2 - 2CP
OPERATING PRINCIPLES COMBIPRESS are twin pump pressure boosting sets supplied preassembled and ready to install. The sets are designed so that the pumps operate automatically in succession as the demand for water increases. This results in significant energy savings as the second pump only runs at times of high demand. The lead pump is alternated automatically by the control box.
USES
•• Clean water and chemically non-aggressive liquids. •• Water supply: pressure boosting in industrial applications, ••
condominiums, hotels, communities, water treatment plants, campsites, schools, hospitals, barracks, etc Irrigation: playing fields in general (football, golf, etc), agricultural cultivation, artificial snow systems.
CONSTRUCTION CHARACTERISTICS
•• PUMPS •• •• ••
complete with suction and delivery manifolds, ball valves and non-return valves BASE made from sheet metal PRE-INSTALLED control systems, comprising a pressure gauge and two user-adjustable pressure switches (the factory settings are indicated in the following tables), fitted to the delivery manifold. CONTROL BOX complete with door-interlock power switch, low voltage pressure switch command circuit, automatic pump alternation function, thermal overload protection and pump start-up protection (prevents the pumps from continuously starting-up as a result of small and brief supply demands). CB2m: single-phase 230 V - 50 Hz. CB2: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 18.5 kW.
GUARANTEE CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
342
1 year subject to terms and conditions
PERFORMANCE DATA
50 Hz n= 2900 1/min HS= 0 m
MODEL
POWER 1~ 3~
CB2 - 4CP 100-C
kW
Q
HP
MODEL
POWER 1~ 3~
kW
l/min
H metres
2x0.75 2 x 1
m³/h
Q
HP
0
0.6
1.2
2.4
3.6
4.8
7.2
8.4
0
10
20
40
60
80
120
140
50
50
49
47
45
42
37
34
9.6
10.8
12.0
13.2
14.4
15.6
160
180
200
220
240
260
22
17
11
5
30.5 26.5
m³/h
0
2.4
4.8
7.2
l/min
0
40
80
120 160 200 220 240 280 320 360 400 500 600 700 800
9.6 12.0 13.2 14.4 16.8 19.2 21.6 24.0 30.0 36.0 42.0 48.0
39
34 28.5 22
CB2 - 2CP 25/130N
2x0.75 2 x 1
42
CB2 - 2CP 25/14B
2x1.1
2 x 1.5
54
52
47.5
41
33
22
CB2 - 2CP 25/16C
2x1.1
2 x 1.5
47
46
44
40
35
30
27
CB2 - 2CP 25/16B
2x1.5
2x2
58
56
54
51
47
43
40
37
30
CB2 - 2CP 25/16A
2x2.2
2x3
68
67 64.5 62
58
54
51
48
41
CB2 - 2CP 32/200C
2x3
2x4
CB2 - 2CP 32/200B
2x4
2 x 5.5
CB2 - 2CP 32/210B
2x5.5
CB2 - 2CP 32/210A
2x7.5
CB2 - 2CP 40/180C
24 32
70
–
85
–
2 x 7.5
94
2 x 10
112
2x4
2 x 5.5
64
–
–
–
–
62
43
35
CB2 - 2CP 40/180B
2x5.5
2 x 7.5
76
–
–
–
–
73 72.5 72
71.0 70.0
69
67.5
64
59.5
54
46
CB2 - 2CP 40/180A
2x7.5
2 x 10
88
–
–
–
–
85 84.5 84 83.0 82.0
81
79.5
76
72
67
60
H metres
66.5 65
15
63 60.5 59
58
55
52
81
79
77
75
74
72
69
66
–
94
93
91
89
87
86
83
79
–
111 110.5 110 108 107 106 102
99
61.3 60.5 59.0 57.5
49.5 46.5 36 62
58
49
75
70
56
94
89
74
56 54.5 49
DIMENSIONS AND WEIGHT g g DN2
DN2
d
DN1
e
e
f
f
c
DN1
c
d
h
a
h
a
b
CB2-4CP • CB2 -2CP 25/ • CB2-2CP 32/ MODEL
CB2-2CP 40/
PORTS Three-phase
DN1
CB2 - 4CPm100-C
–
1½"
1½"
CB2 - 2CPm 25/130N
CB2 - 2CP 25/130N
1½"
1½"
Single-phase
CB2 - 2CPm 25/14B
CB2 - 2CP 25/14B
CB2 - 2CPm 25/16C
CB2 - 2CP 25/16C
CB2 - 2CPm 25/16B
CB2 - 2CP 25/16B
–
CB2 - 2CP 25/16A
–
CB2 - 2CP 32/200C
–
CB2 - 2CP 32/200B
–
CB2 - 2CP 32/210B
–
CB2 - 2CP 32/210A
–
CB2 - 2CP 40/180C
–
CB2 - 2CP 40/180B
–
CB2 - 2CP 40/180A
DN2
DIMENSIONS mm a
b
c
520
645
520
600
1½"
615
e
f
g
630
315
190
495
500
620
300
155
420
338
170
455
645 711 910
3"
351 780
80
190
400
2"
500
h
920
980
895
77.5
–
51.0
50.5
68.5
68.0
68.5
68.0
380
472
780
420
590
210
610
700
3~
305
600
430
1~
305
200 700
100
kg
d
598 2"
b
565
77.5
77.0
–
80.0
–
119.0
–
125.0
–
156.0
–
163.0
–
175.0
–
185.0
–
195.0
343
EASYSMALL® Electronic pump controllers
PERFORMANCE RANGE
•• Max flow rate: 200 l/min (12 m3/h) •• Working pressure: 10 bar •• Restarting pressure: 1.5 bar
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 001774928 •• EASYSMALL® registered trade mark n° 1511131
OPTIONALS AVAILABLE ON REQUEST
•• Maximum liquid temperature +50 °C •• Ambient temperature up to +40 °C •• Burst pressure 40 bar •• Protection grade: IP 65 •• Voltage: 230 V - Frequency: 50/60 Hz •• Max current: – 12 A-EASYSMALL-1
– 16 A-EASYSMALL-2
CONSTRUCTION AND SAFETY STANDARDS
•• The easy to replace, tropicalized sealed circuit board offers com••
plete protection from the effects of humidity and is housed in an IP 65 case. The EASYSMALL circuit board has passed the most stringent EMC tests for electromagnetic compatibility (low interference emission and high disturbance immunity), guaranteeing reliable operation in any environment.
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE Flow & pressure sensing device for control and protection of single- phase pumps up to 2 HP (for domestic applications). It starts the pump when there is a drop in system pressure (e.g. a tap opening) and stops the pump when the flow drops below 2 l/min (tap closed)..
344
•• Version with pressure gauge
GUARANTEE 1 year subject to terms and conditions
INSTALLATION EXAMPLES To avoid repeated starts and to save energy, we recommend that EASYSMALL is installed with a small pressure vessel (ES-05).
Tank ES-05 with pre-set 1.2 bar (recommended)
Maximum delivery height 11 m
APPLICATION LIMITS
PRESSURE LOSSES
Pressure losses (m H2O) 4
15
10
5
0
0
50
100
150
200
0
3
6
9
12
MODEL
Power
Flow rate Q 4
l/min m3/h
Volt
Hz
Current
Fittings
Flow rate
Restarting pressure
EASYSMALL-1
kW 0.75
HP 1
230
50/60
12 A
1" x 1"
12 m³/h
1.5 bar
EASYSMALL-2
1.5
2
230
50/60
16 A
1" x 1"
12 m³/h
1.5 bar
DIMENSIONS AND WEIGHT
ACCESSORIES
•• ES-05: Stainless steel vessel of 0.5 l capacity. 1" BSP male thread. •• GSR: 3 piece male unions for quick connection of pump/EASY SMALL.
g
h
c
a
d
e
b
f
MODEL
i
PORTS
l
DIMENSIONS mm f
g
h
kg
a
b
c
d
e
i
EASYSMALL 1-2 1"
1"
1"
56
74 130 100 170 36
ES-05
GSR
l 64 0.7
PALLETIZATION MODEL Single-phase EASYSMALL 1-2
n°
H (mm)
kg
324
1230
247
H
0 80
00
12
345
EASYPRESS® Electronic pump controllers
PERFORMANCE RANGE
PATENTS - TRADE MARKS - MODELS
APPLICATION LIMITS
OPTIONALS AVAILABLE ON REQUEST
•• Max flow rate: 200 l/min (12 m3/h) •• Working pressure: 10 bar •• Restarting pressure: 1.5 bar •• Maximum liquid temperature +65 °C •• Ambient temperature up to +40 °C •• Burst pressure > 40 bar •• Protection: IP 65 •• VOLTAGE: 230 V - Frequency: 50/60 Hz •• Max current: – 10 A EASYPRESS-1
– 16 A EASYPRESS-2
CONSTRUCTION AND SAFETY STANDARDS
•• The easy to replace, resin sealed circuit board offers complete ••
protection from the effects of humidity and is housed in an IP 65 case. The EASYPRESS circuit board has passed the most stringent EMC tests for electromagnetic compatibility (low interference emission and high disturbance immunity), guaranteeing reliable operation in any environment.
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
INSTALLATION AND USE The EASYPRESS series consists of electronic devices designed to start (when a tap is turned on) and stop (when a tap is turned off) single-phase pumps. The microprocessor protects the pump from dangerous working conditions, such as dry running, and allows the pump to be restarted either automatically or manually. It also prevents the pump from starting-up too often when small leaks are present within an installation.
346
•• Registered Community Design n° 868062 •• Patent n° IT 1388969, IT 1388970 •• EASYPRESS® registered trade mark n° 1334481 •• Version with restating pressure 0.8 bar •• Version with restating pressure 2.2 bar •• Version with 1" NPT ports •• Version with cable and Schuko plug and socket •• Version with pressure gauge
GUARANTEE 1 year subject to terms and conditions
START-UP PRESSURE There are three different models available to choose from, each with a different start-up pressure and easily identified by the coloured cap positioned at the rear of EASYPRESS, suitable for delivering supply to different heights.
Maximum delivery height Version 2.2 bar
= 18 m
Version 1.5 bar
= 11 m
Version 0.8 bar
= 5 m
PRESSURE LOSSES
Pressure losses (m H2O) 4
15
10
5
0
0
50
100
0
3
6
150
200
9
12
l/min m3/h
Flow rate Q 4 MODEL
Power
Volt
Hz
Current
Fittings
Flow rate
Restarting pressure
1
230
50/60
10 A
1" x 1"
12 m³/h
1.5 bar
2
230
50/60
16 A
1" x 1"
12 m³/h
1.5 bar
kW
HP
EASYPRESS-1
0.75
EASYPRESS-2
1.5
DIMENSIONS AND WEIGHT c
MODEL EASYPRESS 1-2
PORTS
DIMENSIONS mm
a
kg
a
b
c
d
h
1"
1"
221
174
174
d
1.63
4
6 8
2 bar
10
h
0
Quick-fit joint with o-ring MODEL
FITTING
GSR
1" M b
PALLETIZATION MODEL Single-phase EASYPRESS 1-2
n°
H (mm)
kg
147
1450
257
H
0
80
00
12
347
EASYPRO® Electronic pump controller
PERFORMANCE RANGE
•• Max flow rate: 200 l/min (12 m3/h) •• Working pressure: 10 bar •• Restarting pressure: 2 bar (Adjustable between 1 and 5 bar)
APPLICATION LIMITS
•• Maximum liquid temperature +65 °C •• Ambient temperature up to +40 °C •• Burst pressure: > 40 bar •• Protection: IP 65 •• Voltage: 230 V - Frequency: 50/60 Hz - Max current: 16 A
CONSTRUCTION AND SAFETY STANDARDS
•• Easy to replace, resin sealed circuit board for complete protection from the effects of humidity.
•• The pressure sensor is housed in a separate area, isolated from the circuit board and current carrying components.
•• The EASYPRO circuit board has passed the most stringent EMC
tests for electromagnetic compatibility (low interference emission and high disturbance immunity), guaranteeing reliable operation in any environment.
CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY
GUARANTEE 1 year subject to terms and conditions
348
INSTALLATION AND USE EASYPRO® differs from traditional PRESSURE-FLOW REGULATORS as a result of the following innovative characteristics: •• the built-in surge tank; •• the possibility of selecting the restarting pressure of the pump; •• the back-lit LCD display where the pressure and other useful information is indicated. PUMP START-UP PRESSURE EASYPRO® allow to select the restarting pressure of the pump, between 1 and 5 bar. The pressure selection is made using the command button and by following the instructions that appear on the LCD display. A single model is capable of covering a wide range of installation requirements. SURGE TANK EASYPRO® comes complete with a built-in 3 litre surge tank. The substantial accumulation volume combined with its ability to absorb over-pressure, a typical surge tank characteristic, make it suitable for use in installations where other pressure-flow regulators may prove inadequate. In order to guarantee optimum protection and accumulator performance, it is possible to adjust the tank pressure, the factory setting is 1.8 bar, to suit the pump start pressure selected.
PATENTS - TRADE MARKS - MODELS
•• Registered Community Design n° 976824 •• Patent Pending n° IT 1388969, IT 1388970 •• EASYPRO® registered trade mark n° 1334546
OPTIONALS AVAILABLE ON REQUEST
•• Version with 1" NPT ports •• Version with cable and Schuko plug and socket •• Version with pressure gauge
PRESSURE LOSSES
Pressure losses (m H2O) 4
15
10
5
0
0
50
100
0
3
6
150
200
9
12
l/min m3/h
Flow rate Q 4 MODEL EASYPRO
Power kW HP
Volt
Hz
Current
Fittings
Flow rate
Adjustable restarting pressure
1.5
230
50/60
16 A
1" x 1"
12 m³/h
1÷5 bar
2
DIMENSIONS AND WEIGHT c
a
b
EASYPRO
1"
1"
DIMENSIONS mm c
d
e
283 162 192
kg
h 174
2.43 h
PORTS
d
MODEL
e
a
Quick-fit joint with o-ring MODEL
FITTING
GSR
1" M
b
PALLETIZATION MODEL Single-phase
n°
H (mm)
kg
EASYPRO
98
1450
255
H
0
80
00
12
349
ACCESSORIES SF - SPHERICAL TANK MODEL
FITTING
CAPACITY
1"
24 litres
MODEL
FITTING
CAPACITY
24 CL
1"
20 litres
60 CL
1"
60 litres
100 CL
1"
100 litres
200 CL
1½"
200 litres
300 CL
1½"
300 litres
MODEL
FITTING
CAPACITY
05 VT
½"
0.5 litres
8
VT
1"
8 litres
19 VT
1"
19 litres
60 VT
1"
60 litres
100 VT
1"
100 litres
200 VT
1½"
200 litres
300 VT
1½"
300 litres
500 VT
1½"
500 litres
24 SF
•• Maximum working pressure 8 bar •• Replaceable butyl rubber diaphragm
CL - CYLINDRICAL TANKS
•• Maximum working pressure 10 bar •• Replaceable butyl rubber diaphragm
VT - VERTICAL TANKS
•• Maximum working pressure 10 bar (8 bar for 8VT, 19VT) •• Replaceable butyl rubber diaphragm
350
SPHERICAL KIT MODEL KSP-05
KSP-05 •• 0.5 litres spherical tank •• 4-way fitting - 1" gas •• Pressure switch "PSG-1" •• Power cable with Schuko plug KSP-24 •• 24 litres spherical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Pressure switch "PSG-1"
KSP-24
KSD-24 •• 24 litres spherical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Pressure switch "FSG2" (Square D)
CYLINDRICAL KIT KCP-24
MODEL KCP-24 •• 20 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (500 mm) •• Pressure switch "PSG-1" KCD-24 •• 20 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (500 mm) •• Pressure switch "FSG2" (Square D)
KCP-60
MODEL KCP-60 •• 60 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (600 mm) •• Pressure switch "PSG-1" KCD-60 •• 60 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (600 mm) •• Pressure switch "FSG2" (Square D)
351
ACCESSORIES AIRFLO - AUTOMATIC AIR FEEDERS MODEL
SUITABLE FOR TANKS
AIRFLO 1
100 ÷ 500 litres
AIRFLO 2
750 ÷ 2000 litres
•• Automatic air feeders suitable for maintaining the air cushion in surge tanks without a diaphragm.
NA - 3-WAY NIPPLE FOR AIR FEEDERS NA 1.00
CENTRAL FITTING DOUBLE FITTING 1" x 1" ½" x ¼" (male/female)
NA 1.50
NA 1.25
1¼" x 1¼"
NA 2.00
MODEL
MODEL
½" x ¼" (male/female)
CENTRAL FITTING DOUBLE FITTING 1½" x 1½" ½" x ¼" (male/female) 2" x 2"
½" x ¼" (male/female)
•• 3-way brass fittings for connections with air feeders (AIRFLO)
PRESSURE SWITCHES
PSG
MODEL
FITTING
STANDARD SETTING ✱
PSG-1
¼" female
PSG-1M
¼" male
1.4 ÷ 2.8 bar
FSG 2
¼" female
1.4 ÷ 2.8 bar
FYG 22
¼" female
5.4 ÷ 7.0 bar
FYG 32
¼" female
8 ÷ 10.5 bar
PT/5 SK (1)
¼" female
1.4 ÷ 2.8 bar
1.4 ÷ 2.8 bar
•• PSG Registered Community Design nº 002248955 (✱) Adjustable (1) Three-phase
FSG
PRESSURE GAUGES MODEL MC 6
MC
FITTING
DIAMETER
SCALE
¼" - central
50 mm
0 ÷ 6 bar
MR 6
¼" - radial
63 mm
0 ÷ 6 bar
MR 10
¼" - radial
63 mm
0 ÷ 10 bar
MR
GLYCERIN FILLED PRESSURE GAUGES
MCG
352
MRG
MODEL
FITTING
DIAMETER
SCALE
MCG 6
¼" - central
50 mm
0 ÷ 6 bar
MRG 6
¼" - radial
63 mm
0 ÷ 6 bar
MRG 10
¼" - radial
63 mm
0 ÷ 10 bar
3 - 5 WAY FITTINGS MODEL
R5 R4 R3
FITTING
R 3 - 3 way
1"
R 4 - 4 way
1"
R 5 - 5 way
1"
•• R 3: three-way brass fittings with 1" gas connections •• R 4: four-way brass fittings with ½" gas and ¼" gas connections •• R 5: five-way brass fittings with 1" gas and ¼" gas connections
HOSES MODEL TF
PIPE
FITTINGS
TF 5
1"
1" x 1"
500 mm
TF 6
1"
1" x 1"
600 mm
TF 10
1"
1" x 1"
1000 mm
•• Flexible EPDM rubber hoses
LENGTH
•• Maximum working pressure 10 bar
HOSES COMPLETE WITH ELBOW TFG
MODEL
PIPE
FITTINGS
TFG 5
¾"
1" x 1"
500 mm
TFG 6
1"
1" x 1"
600 mm
•• Flexible EPDM rubber hoses
LENGTH
•• Maximum working pressure 10 bar
STRAIGHT HOSETAIL FITTINGS MODEL
HOSETAIL
THREADED FITTING
RP 0.75
Ø 25 mm
¾"
RP 1
Ø 30 mm
1"
RP 1.25
Ø 35 mm
1¼"
RP 1.5
Ø 40 mm
1½"
RP 2
Ø 50 mm
2"
•• Nylon fittings CURVED HOSETAIL FITTINGS MODEL
HOSETAIL
THREADED FITTING
RPG 0.75
Ø 25 mm
¾"
RPG 1
Ø 30 mm
1"
RPG 1.25
Ø 35 mm
1¼"
RPG 1.5
Ø 40 mm
1½"
RPG 2
Ø 50 mm
2"
•• Nylon fittings 353
ACCESSORIES FLOAT SWITCHES MODEL
CABLE (*)
LENGTH (*)
0315/3
H07 RN-F or PVC
3 metres
0315/5
H07 RN-F or PVC
5 metres
0315/10
H07 RN-F or PVC
10 metres
•• With H07 RN-F cable: single function (emptying) floats, with 10 A switch •• With PVC cable: dual function (emptying and filling) floats, with 10 A switch
MODEL
CABLE (*)
LENGTH (*)
T 80/3
H07 RN-F or PVC
3 metres
T 80/5
H07 RN-F or PVC
5 metres
T 80/10
H07 RN-F or PVC
10 metres
•• With H07 RN-F cable: - single function (emptying) floats,
•• With PVC cable:
with double watertight protection chamber and 10 A switch - dual function (emptying and filling) floats - double watertight protection chamber and 10 A switch
MODEL
CABLE (*)
LENGTH (*)
SMALL 3
H07 RN-F or PVC
3 metres
SMALL 5
H07 RN-F or PVC
5 metres
•• With H07 RN-F cable: -single function (emptying) floats,
•• With PVC cable:
with double watertight protection chamber and 10 A switch - dual function (emptying and filling) floats - double watertight protection chamber and 10 A switch
(*) ➠ When ordering, please specify cable length (3, 5 or 10 metres) and type (H07 RN-F or PVC)
MODEL
CABLE
LENGTH
MAC 5
PVC
10 metres
•• Tilting float: - dual function (emptying and filling)
- double watertight protection chamber with 10 A switch
➠ Recommended for use with waste water collection stations (SAR)
354
VF - FOOT VALVES MODEL
FITTING
VF 0.5
½"
VF 0.75
¾"
VF 1
1"
VF 1.25
1¼"
VF 1.5
1½"
VF 2
2"
•• Brass foot valves, stainless steel suction filter
VR - CHECK VALVES MODEL
FITTINGS
VR 0.5
½"
VR 0.75
¾"
VR 1
1"
VR 1.25
1¼"
VR 1.5
1½"
VR 2
2"
•• Brass check valves
VR-FT - BALL CHECK VALVES MODEL
FITTINGS
VR-FT 1.25 - THREADED
1¼"
VR-FT 1.5 - THREADED
1½"
VR-FT 2 - THREADED
2"
•• Check valves for submersible pumps (sewage and waste water) •• Max. working pressure 10 bar •• Min. working pressure 0.3 bar •• Working temperature -10°C ÷ +80 °C
VR-FF - BALL CHECK VALVES MODEL
FITTINGS
VR-FF/DN 65 - FLANGED
Ø 65 mm
VR-FF/DN 80 - FLANGED
Ø 80 mm
•• Check valves for submersible pumps (sewage and waste water) •• Max. working pressure 10 bar •• Min. working pressure 0.3 bar •• Working temperature -10°C ÷ +80 °C 355
ACCESSORIES F - FILTER HOLDERS WITH PLASTIC HEAD MODEL
THREADED FITTINGS
CARTRIDGE HEIGHT
¾"
5"
MEDIUM - F 0.75 MEDIUM - F 1
1"
5"
JUNIOR - F 0.75
¾"
7"
JUNIOR - F 1
1"
7"
SENIOR - F 0.75
¾"
10"
SENIOR - F 1
1"
10"
•• Maximum working pressure 5 bar (at temp. +20°C) •• Maximum temperature + 45°C (at pressure 2 bar) Wrench for filter holders F
RL - POLYESTER FILTER CARTRIDGES MODEL
FILTRATION
CARTRIDGE HEIGHT
FILTER HOLDER
RL 5
50 µ
5"
MEDIUM F
RL 7
50 µ
7"
JUNIOR F
RL 10
50 µ
10"
SENIOR F
FA - POLYPROPYLENE FILTER CARTRIDGES MODEL
FILTRATION
CARTRIDGE HEIGHT
FILTER HOLDER
FA 5
50 µ
5"
MEDIUM F
FA 7
50 µ
7"
JUNIOR F
FA 10
50 µ
10"
SENIOR F
HA - FILTER CARTRIDGE WITH POLYPHOSPHATE CRYSTALS MODEL HA 10
CARTRIDGE HEIGHT
FILTER HOLDER
10"
SENIOR F
LA - FILTER CARTRIDGE WITH ACTIVATED CARBON
356
MODEL
CARTRIDGE HEIGHT
FILTER HOLDER
LA 10 BX
10"
SENIOR F
FLAT PVC HOSE MODEL
FITTING
Ø INTERNAL
LENGTHS
TP 1.25
1¼"
32 mm
5 - 10 - 20 metres
TP 1.50
1½"
40 mm
5 - 10 - 20 metres
TP 2.00
2"
52 mm
5 - 10 - 20 metres
TP 2.50
2½"
63 mm
5 - 10 - 20 metres
TP 3.00
3"
76 mm
5 - 10 - 20 metres
•• Flat, abrasion and weather resistant plasticized delivery hoses, complete with hosetail. ➠ Ideal for irrigation even with fertilisers and for draining water in combination with DRAINAGE PUMPS
GARDEN KIT - SUCTION HOSE MODEL
FITTING
LENGTH
1"
7 metres
GARDEN KIT
•• Hose complete with foot valve ➠ Recommended for use with portable garden pumps such "BETTY"
MT 1 - MECHANICAL FLOW METRE MODEL
MAXIMUM FLOW RATE
MAXIMUM PRESSURE
FITTINGS
120 l/min
3.5 bar
1" x 1"
MT 1
•• Mechanical flow metre for private use, suitable for measuring diesel fuel ➠ Recommended for use with "CK" series pumps
NZ - DISPENSING NOZZLE WITH HOSE MODEL NZ
ELBOW CONNECTION 1” or ¾"
•• Aluminium dispensing nozzle complete with 4 meters long hose, reinforced with steel spiral, with threaded fittings
➠ Recommended for use with "CKm 50-BP or CK 50-BP" series pumps
357
ACCESSORIES TEFLON TAPE FOR HYDRAULIC JOINTS MODEL
LENGTH
TFN 1
12 m
TFN 2
30 m
TFN 3 ¾"
12 m
AEROSOL PAINT MODEL
COLOUR
CAPACITY
SPRAY 1
Pedrollo blue
400 ml
"3M" ELECTRICAL CABLE RESIN JOINT KIT No. OF CORES
CABLE SECTION
RPS 1
4
1 ÷ 2.5 mm²
EXTERNAL JUNCTION DIAMETRE Ø 32 mm
RPS 2
4
1 ÷ 10 mm²
Ø 42 mm
RPS 3
4
4 ÷ 16 mm²
Ø 48 mm
MODEL
(RECOMMENDED)
"3M" ELECTRICAL CABLE HEAT-SHRINK JOINT KIT MODEL
(ECONOMICAL)
358
No. OF CORES
CABLE SECTION
GPS 1
4
1 ÷ 2.5 mm²
GPS 2
4
4 ÷ 6 mm²
GPS 3
4
10
mm²
GPS 4
4
16
mm²
GPS 5
4
25
mm²
GPS 6
4
35
mm²
CAPACITORS MODEL
type F= faston
06 F 10 F 10 FC (*) 12 F 14 F 16 F - 500 16 F - 450 16 F - 250 20 F - 500 20 F - 450 25 F - 450 25 F - 250 30 F - 450 30 F - 250 31 F 35 F 40 F 45 F 50 F 60 F - 450 60 F - 300 60 F - 250 70 F 80 F
CAPACITANCE
Voltage
Frequency
6.3 µF 10 µF 10 µF 12.5 µF 14 µF
450 V 450 V 450 V 450 V 450 V 500 V 450 V 250 V 500 V 450 V 450 V 250 V 450 V 250 V 450 V 450 V 450 V 450 V 450 V 450 V 300 V 250 V 450 V 250 V
50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz
CAPACITANCE
Voltage
Frequency
10 µF 12.5 µF
450 V 450 V 500 V 450 V 500 V 450 V 500 V 450 V 250 V 500 V 450 V 500 V 450 V 450 V 450 V 250 V 250 V 450 V 250 V
50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz
16 µF 20 µF 25 µF 30 µF 31.5 µF 35 µF 40 µF 45 µF 50 µF 60 µF 70 µF 80 µF
•• Capacitors with CE marking and VDE-IMQ approval
(*) FC = Special capacitor with reduced dimensions
CAPACITORS MODEL
type C= with cable
10 C 12 C 16 C - 500 16 C - 450 20 C - 500 20 C - 450 25 C - 500 25 C - 450 30 C - 250 31 C - 500 31 C - 450 35 C - 500 35 C - 450 40 C 50 C 60 C 70 C 75 C 80 C
16 µF 20 µF 25 µF 30 µF 31.5 µF 35 µF 40 µF 50 µF 60 µF 70 µF 75 µF 80 µF
•• Capacitors with CE marking and VDE-IMQ approval
359
ACCESSORIES ELECTRICAL CABLE FOR LEVEL PROBES MODEL
SECTION
WEIGHT PER METRE
CSL
1.5 mm²
0.019 kg
POWER CABLE FOR SUBMERSIBLE PUMPS MODEL
MODEL
WEIGHT PER METRE
mm²
H07 RN-F
0.165 kg
4 x 1.5 mm²
H07 RN-F
0.205 kg
4 x 2.5 mm²
H07 RN-F
0.290 kg
4 x 4
mm²
H07 RN-F
0.420 kg
4 x 6
mm²
H07 RN-F
0.505 kg
4 x 10 mm²
H07 RN-F
1.030 kg
4 x 16 mm²
H07 RN-F
2.050 kg
4 x 1
POWER CABLE WITH PLUG MODEL
360
CABLE SECTION
LENGTH
PLUG
H05 VV-F (PVC)
3 x 0.75 mm²
150 cm
SCHUKO
H07 RN-F (NEOPRENE)
3x1
150 cm
SCHUKO
mm²
BEARINGS MODEL 6201 ZZ 6201 2RS - C3 6202 ZZ - C3 6203 ZZ 6203 ZZ - C3 6203 ZZ - C3E 6203 2RS 6204 ZZ - C3 6204 ZZ - C3E 6205 ZZ 6206 ZZ - C3 6208 ZZ - C3 6212 ZZ - C3 6303 ZZ - C3 6303 2RS - C3 6304 ZZ 6304 ZZ - C3 6304 2RS - C3 6306 ZZ - C3 6307 ZZ - C3 6308 ZZ - C3 6309 ZZ - C3 6310 ZZ - C3 6312 ZZ - C3 6314 ZZ - C3 3203 B - C3
INTERNAL PLAY
DIMENSIONS
Normal Increased Increased Normal Increased Increased Normal Increased Increased Normal Increased Increased Increased Increased Increased Normal Increased Increased Increased Increased Increased Increased Increased Increased Increased Increased
12 x 32 x 10 mm 12 x 32 x 10 mm 15 x 35 x 11 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 20 x 47 x 14 mm 20 x 47 x 14 mm 25 x 52 x 15 mm 30 x 62 x 16 mm 40 x 80 x 18 mm 60 x 110 x 22 mm 17 x 47 x 14 mm 17 x 47 x 14 mm 20 x 52 x 15 mm 20 x 52 x 15 mm 20 x 52 x 15 mm 30 x 72 x 19 mm 35 x 80 x 21 mm 40 x 90 x 23 mm 45 x 100 x 25 mm 50 x 110 x 27 mm 60 x 130 x 31 mm 70 x 150 x 35 mm 17 x 40 x 17.5 mm
FANS MODEL
DIMENSIONS
SHAFT DIAMETER
14VN059 14VN07 14VN075 14VN08 14VN081 14VN0815 14VN09 14VN95 14VN10 14VN10162 14VN132 14VN180
104 x 21 mm 125 x 24 mm 118 x 22 mm 138 x 27 mm 132 x 27 mm 132 x 27 mm 162 x 32 mm 148 x 33 mm 176 x 38 mm 155 x 37 mm 165 x 45 mm 240 x 60 mm
12 mm 14.5 mm 14.5 mm 20 mm 20 mm 20 mm 24 mm 24 mm 28 mm 28 mm 36 mm 55 mm
361
CABLE SIZES FOR SUBMERSIBLE MOTORS SINGLE-PHASE 230 V - 50 Hz MOTOR POWER kW
HP
0.37 0.55 0.75 1.1 1.5 2.2
0.50 0.75 1 1.5 2 3
cable section in mm2 4x1
4 x 1.5
4 x 2.5
60 45 35 25
90 70 50 35 30
140 110 85 60 45 30
4x4
4x6
4 x 10
4 x 16
240 190 125
305 200
maximum cable length in metres 180 140 95 75 50
210 145 115 75
THREE-PHASE 230 V - 50 Hz MOTOR POWER kW
HP
0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9.2 11 13 15 18.5 22 30
0.50 0.75 1 1.5 2 3 4 5.5 7.5 10 12.5 15 17.5 20 25 30 40
cable section in mm2 4x1
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
385 275 220 190 164 144 114 95 70
395 315 270 236 205 162 137 102
378 330 287 225 190 142
4 x 25
4 x 35
4 x 50
4 x 70
585 470 405 350 305 245 205 152
490 430 340 285 210
485 410 305
570 425
maximum cable length in metres 100 83 65 48
152 126 99 72 53
255 210 165 120 88 60 47
338 265 192 142 97 73 55
405 292 215 147 110 83 60 45
485 360 245 183 138 100 73 64 54
392 295 220 160 114 100 87 75 65
510 380 275 195 157 135 117 102 82 69
THREE-PHASE 400 V - 50 Hz MOTOR POWER kW
HP
0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9.2 11 13 15 18.5 22 30
0.50 0.75 1 1.5 2 3 4 5.5 7.5 10 12.5 15 17.5 20 25 30 40
cable section in mm2 4x1
4 x 1.5
4 x 2.5
4x4
4x6
300 250 195 145 105 70 55 40
380 295 215 160 110 85 60 45 35
360 265 180 140 105 75 55 47 40
425 290 220 165 120 95 75 65 60 50
440 330 250 180 135 115 95 85 75 58 49 36
Voltage drop 3% - Maximum environment temperature + 30 째C
366
4 x 10
4 x 16
maximum cable length in metres
415 300 220 190 160 140 125 100 85 63
480 340 300 260 225 195 155 130 96
CONTROL BOXES QEM - CONTROL BOXES FOR 4" SINGLE-PHASE BOREHOLE PUMPS MODEL
MOTOR POWER
CAPACITOR
RATED CURRENT
Single-phase
kW
HP
CAPACITANCE
A
QEM 050
0.37
0.50
20 µF
5
QEM 075
0.55
0.75
25 µF
6
QEM 100
0.75
1
35 µF
7
QEM 150
1.1
1.5
40 µF
11
QEM 200
1.5
2
60 µF
13
QEM 300
2.2
3
75 µF
18
•• Single-phase 230 V 50 Hz
QET - CONTROL BOXES FOR 4" AND 6" THREE-PHASE BOREHOLE PUMPS MODEL
MOTOR POWER
RATED CURRENT
Three-phase
kW
HP
A
QET 050
0.37
0.50
1.7
QET 075
0.55
0.75
2
QET 100
0.75
1
2.5
QET 150
1.1
1.5
3.9
QET 200
1.5
2
4.8
QET 300
2.2
3
7
QET 400
3
4
9
QET 550
4
5.5
11.5
QET 750
5.5
7.5
15.5
QET 1000
7.5
10
21.5
QET 1250
9.2
12.5
23.5
QET 1500
11
15
27.5
QET 2000
15
20
36
QET 2500
18.5
25
45
QET 3000
22
30
54
QET 4000
30
40
68
•• The control box has a selector for manual or automatic operation (with float switch, pressure switch, etc.).
•• Three-phase 400 V 50 Hz
362
QSM - CONTROL BOXES FOR 4" SINGLE-PHASE PUMPS WITH LEVEL PROBES
Level probes
MODEL
MOTOR POWER
CAPACITOR
RATED CURRENT
Single-phase
kW
HP
CAPACITANCE
A
QSM 050
0.37
0.50
20 µF
5
QSM 075
0.55
0.75
25 µF
6
QSM 100
0.75
1
35 µF
7
QSM 150
1.1
1.5
40 µF
11
QSM 200
1.5
2
60 µF
13
QSM 300
2.2
3
75 µF
17.5
•• The control box has a selector for manual or automatic operation (with float switch, pressure ••
switch, etc.) and may be connected to level probes that protect the pump against dry running. Single-phase 230 V 50 Hz
QST - CONTROL BOXES FOR 4"AND 6" THREE-PHASE PUMPS WITH LEVEL PROBES MODEL
Level probes
MOTOR POWER
RATED CURRENT
Three-phase
kW
HP
A
QST 50
0.37
0.50
1.7
QST 75
0.55
0.75
2
QST 100
0.75
1
2.5
QST 150
1.1
1.5
3.9
QST 200
1.5
2
4.8
QST 300
2.2
3
7
QST 400
3
4
9
QST 550
4
5.5
11.5
QST 750
5.5
7.5
15.5
QST 1000
7.5
10
21.5
QST 1250
9.2
12.5
23.5
QST 1500
11
15
27.5
QST 2000
15
20
36
QST 2500
18.5
25
45
QST 3000
22
30
54
QST 4000
30
40
68
•• The control box has a selector for manual or automatic operation (with float switch, pres••
sure switch, etc.) and may be connected to level probes that protect the pump against dry running. Three-phase 400 V 50 Hz
363
CONTROL BOXES EVOLUTION - CONTROL BOXES FOR 4" AND 6" BOREHOLE PUMPS MODEL
VOLTAGE
RATED CURRENT A
Single-phase 230 V 50 Hz Three-phase 400 V 50 Hz Three-phase 400 V 50 Hz
EVOLUTION-MONO EVOLUTION-TRI/1 EVOLUTION-TRI/2
from 2 to 18 from 2 to 16 from 16 to 22
•• The control box contains a circuit board that makes it possible to adjust the limit at which the over••
load and shot-circuit protection intervenes; the circuit board also protects the pump against dry running by controlling the cos φ value without additional level probes. The control box may be connected to a float switch (or a pressure switch, etc.).
QES - CONTROL BOXES FOR SINGLE PHASE DRAINAGE PUMPS MODEL
MOTOR POWER
CAPACITOR
RATED CURRENT
Single-phase
kW
HP
CAPACITANCE
A
QES 300 MONO
2.2
3
60 µF
16
QES 300 MONO-AL (*)
2.2
3
60 µF
16
➠ The control box is designed for connection to the thermal protector built into the motor windings of the VXCm30, PVXCm30, MCm30, PMCm30 drainage pumps. (*) QES 300 MONO-AL, control box with contacts for connection to an auxiliary float switch for level alarm
•• Single-phase 230 V 50 Hz
QES - CONTROL BOXES FOR THREE PHASE DRAINAGE PUMPS MODEL
MOTOR POWER
RATED CURRENT
Three-phase
kW
HP
A
QES 150
1.1
1.5
4.2
QES 200
1.5
2
5.2
QES 300
2.2
3
6.5
QES 400
3
4
8
➠ The control box comes complete with a selector for manual or automatic operation (with float switch) and is designed for connection to the thermal protector built into the motor windings of the VXC, PVXC, MC, PMC drainage pumps.
•• Three-phase 380 ÷ 415V 50 Hz 364
QED 1 - ELECTRONIC CONTROL BOX FOR 1 DRAINAGE PUMP MODEL
VOLTAGE
RATED CURRENT A
QED 1- MONO QED 1- TRI
single-phase 230 V 50 Hz Three-phase 400 V 50 Hz
from 2 to 18 from 2 to 9
➠ The control box is designed for connection to the thermal protector built into the motor windings of the VXC, PVXC, MC and PMC drainage pumps.
•• The control box is designed to be connected to three float switches (start-up, shut-off and alarm level).
•• The control box contains an electronic card that makes it possible to regulate the threshold at which the protection intervenes against overload currents and short-circuits.
QED 2 - ELECTRONIC CONTROL BOX FOR 2 DRAINAGE PUMPS MODEL
VOLTAGE
RATED CURRENT A
QED 2- MONO QED 2- TRI
single-phase 230 V 50 Hz Three-phase 400 V 50 Hz
from 2 to 18 from 2 to 9
➠ The control box is designed for connection to the thermal protector built into the motor windings of the VXC, PVXC, MC and PMC drainage pumps.
•• The control box is designed to be connected to four float switches (alternate start-up of the first pump, alternate start-up of the second pump, shut-off and alarm level)
•• The control box contains an electronic card that makes it possible to regulate the threshold at which the protection intervenes against overload currents and short-circuits.
365
CONVERSION OF UNITS OF MEASUREMENT LENGTH millimetre
centimetre
metre
inch
yard
mm
cm
m
in
ft
yd
1 10 1000 25.4 304.8 914.4
0.1 1 100 2.54 30.48 91.44
0.001 0.01 1 0.0254 0.3048 0.9144
0.0394 0.3937 393.701 1 12 36
0.0033 0.0328 3.2808 0.0833 1 3
0.0011 0.0109 10.936 0.0278 0.3333 1
foot
1 kilometre = 1000 metres = 0.62137 miles – 1 mile = 1609.34 metres = 1.60934 kilometres
VOLUME cubic metre
litre
millilitre
Inperial gallon
US gallon
cubic foot
m3
l
ml
Imp. gal.
US gal
ft3
1000 1 0.001 4.546 3.785 28.317
1 x 10 6 1000 1 4546 3785 28.317
220 0.22 2.2 x 10 -4 1 0.8327 6.2288
264.2 0.2642 2.642 x 10 -4 1.201 1 7.4805
35.3147 0.0353 3.53 x 10 -5 0.1605 0.1337 1
kilogram
pound
hundredweight
ton
long ton
short ton
kg
lb
cwt
t
tn
sh. tn
0.001 4.54 x 10 -4 0.0508 1 1.0161 0.9072
9.84 x 10 -4
0.0011 5.0 x 10 -4 0.056 1.1023 1.102 1
1 0.001 1 x 10 -6 0.00455 0.00378 0.0283
WEIGHT 1 0.454 50.802 1000 1016 907.2
2.205 1 112 2204.6 2240 2000
0.0197 0.0089 1 19.684 20 17.857
4.46 x 10 -4 0.05 0.9842 1 0.8929
VOLUMETRIC FLOW RATE litres second
litres minute
cubic metres hour
cubic feet hour
cubic feet minute
Imp. gal. minute
US gal. minute
l/s 1 0.017 0.278 0.008 0.472 0.076 0.063 0.002
l/min 60 1 16.667 0.472 28.317 4.546 3.785 0.110
m3/h 3.6 0.06 1 0.0283 1.6990 0.2728 0.2271 0.0066
ft3/h 127.133 2.1189 35.3147 1 60 9.6326 8.0209 0.2339
ft3/min 2.1189 0.0353 0.5886 0.0167 1 0.1605 0.1337 0.0039
Imp. gal/min 13.2 0.22 3.666 0.104 6.229 1 0.833 0.024
US gal/min 15.85 0.264 4.403 0.125 7.480 1.201 1 0.029
US barrel day (oil) US barrel/g 543.439 9.057 150.955 4.275 256.475 41.175 34.286 1
PRESSURE AND HEAD Newton square metre N/m2
kiloPascal
bar
kilogram force square centimetre
pound force square inch
foot of water
metre of water
millimetre mercury
inch mercury
(Pa) 1 1000 100000 98067 6895 2984 9789 133.3 3386
kPa 0.001 1 100 98.07 6.895 2.984 9.789 0.133 3.386
bar 1 x 10 -5 0.01 1 0.981 0.069 0.03 0.098 0.0013 0.0338
kgf/cm2 1.02 x 10 -5 1.02 x 10 -2 1.02 1 0.0703 0.0305 0.1 0.0014 0.0345
psi 1.45 x 10 -4 0.145 14.5 14.22 1 0.433 1.42 0.019 0.491
ft H20 3.35 x 10 -4 0.335 33.52 32.81 2.31 1 3.28 0.045 1.133
m H20 1.02 x 10 -4 0.102 10.2 10 0.703 0.305 1 0.014 0.345
mm Hg
In Hg
0.0075 7.5 750.1 735.6 51.72 22.42 73.42 1 25.4
2.95 x 10 -4 0.295 29.53 28.96 2.036 0.882 2.891 0.039 1
368
FRICTION LOSS CHART (for straight pipes with 15-250 mm internal diameter and flow rates from 8 to 8330 l/min)
ee
di
nm
/s
100
Wa ter
sp
50 30 20
10
Loss in metres per 100 metres of pipe
▲
4.6
5 3 2
1
0.5 0.3 0.2
0.1
0.05 0.03 0.02
0.01
8
16
30
50
83
160
330
500
830
1660
3330 5000
8330 Q l/min
0.5
1
2
3
5
10
20
30
50
100
200
500
Q m3/h
▲
Flow rate
300
The data in the table refers to cold water and other liquids with the same kinematic viscosity and new cast iron pipes. The load losses (hv) indicated in the table must be multiplied by: 0.8 for new steel pipes, 1.25 for old, slightly rusty iron pipes, and 1.7 for old pipes where the build-up of incrustation must be taken into account. ➠ EXAMPLE: Flow rate data Q = 500 l/min, new steel pipe Ø 80 mm, pipe length 50 m. Find the flow rate on the horizontal axis and move vertically until you meet the DN 80 mm line. The corresponding load losses can thus be found on the vertical axis. hv = 4,6 m for every 100 m of pipe. hv1 = 4,6 x 0.8 = 3.68 m/100 (steel pipe). Considering the real length of the pipe: hv2 = 3,68 x 50:100 = 1.84 m (for 50 m of pipe). The flow speed is determined by considering the position of the intersection point, which is between the oblique lines with value of 1.5-2 m/sec. In the case considered that gives: C = 1.7 metres/sec
367