Made in Italy – Technology and Design for the future


Pedrollo S.p.A. was founded in 1974. Having grown over the years to assume an international character, the company is now recognised as one of the world leaders in the domestic pump sector. Currently the company covers an area of 100.000 m2 and is characterised by its highly automated production process. The constant quality control of the entire production cycle and the use of the most advanced technological solutions available guarantees that the products are of an extremely high quality. Thanks to the use of the most sophisticated robots and advanced production lines available, the company is capable of producing over 2.000.000 pumps a year from a range covering over 100 different families of pumps.



Pedrollo pumps are sold in over 160 countries worldwide via a sales network capable of offering its clients the choice from a vast range of products suitable for most domestic, civil, agricultural and industrial applications. An international sales team, composed of professionals from various parts of the world, ensures that the client is able to count on an extremely high level of service and personalised advice regarding the best solution to adopt. The research and design department is equipped with the most advanced hardware and software available. A modern laboratory where hydraulic tests take place, workstations where fluiddynamic and finite element analysis is carried out, together with creativity and passion, all combine to produce new pumps and to continually improve the existing range with particular attention being paid to sturdiness and low energy consumption, thus providing each and every client with a simple and reliable product capable of providing surprising levels of performance.



All major components are manufactured ‘in house’ by Pedrollo. Starting with raw materials, the foundry, machine shop, sheet metal works and motor winding facilities, under the guidance of our QA Inspectors, produce high quality precision components at all times.




The final assembly of our pumps takes place on automated assembly lines, capable of providing a high assembly quality while carrying out automated tests at the same time, thus ensuring that the final product is produced in the shortest time possible.



Before approval is given for the production of a new pump, all new models are tested in our laboratory. Fitted with a rig capable of reproducing the most strenuous of working conditions, the laboratory allows us to test the success of the design process.



REGULATION (EU) N. 547/2012 •• Minimum efficiency index MEI ≥ 0,10 for water pumps according to the (EU) Regulation

current from the 1th of January 2013.

•• The benchmark for most efficient water pumps is MEI ≥ 0,70. •• The efficiency of a pump with a trimmed impeller is usually lower than that of a pump

with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter.

•• The operation of this water pump with variable duty points may be more efficient

and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system.

•• Information on benchmark efficiency is available www.europump.org/efficiencycharts.


Index MULTI-STAGE

PERIPHERAL PK

16

2÷4CP

STANDARDIZED CENTRIFUGAL 86

F

130

PKS

PQ PQ-Bs

20

24

PV

32

PQA

36

2÷4CR

90 F-INOX

158

FG

164

VERTICAL MULTI-STAGE

MK

94

SUBMERSIBLE MULTI-STAGE SELF-PRIMING

CENTRIFUGAL CK CP

AL-RED

40

54

CKR

JSW

NK 98

106

4” SUBMERSIBLE PERIPHERAL

DAVIS HF

58

JCR

178

184

118

4” SUBMERSIBLE MONOBLOCK NGA NGA-PRO

66 PLURIJET

2CP

74

122

4BLOCK

188


SUBMERSIBLE

4” SUBMERSIBLE

TOP

SAR

230 328

4SR

192 RX

252 PORTABLE

ZX

272

ZD

276

6” SUBMERSIBLE

6SR

BETTY

336

EASYPUMP-EP

208

D

280

VX-I

284

MC-I

288

VX

292

MC

296

338

HYDROFRESH

340

4” - 6” MOTORS 4PD

220

4FK

222

6PD

224

COMBIPRESS “CB2” DC

300

342 VXC

304

MC

308

SUBMERSIBLE MULTI-STAGE

EASYSMALL-EASYPRESS-EASYPRO 344 346

TOP MULTI

226

PVXC

320

PMC

324

348 ACCESSORIES 350


PK Pumps with peripheral impeller

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. Thanks to their reliability, the fact that they are easy to use and are economical, they are ideal for domestic use and in particular for distributing water in combination with small pressure sets and for the irrigation of gardens and allotments. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 90 l/min (5.4 m³/h) •• Head up to 100 m •• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +60 °C •• Ambient temperature up to +40 °C (+45 °C for PK 60) •• Max. working pressure: ••

– 6.5 bar for PK 60-65-70-80 – 10 bar for PK 90-100-200-300 Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

PATENTS - TRADE MARKS - MODELS

•• Registered model PKm60 n° 009875394 •• Motor bracket: patent n° IT1243605 ••

(reduces the risk of the impeller locking after long periods of inactivity) Registered Community Design n° 001894478

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for PK 70-80-90-100-200-300

GUARANTEE 1 year subject to terms and conditions

16


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

PK300 PK200 PK90

PK100

PK80

Head H (metres) 4

PK70

PK65

PK60

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

3.0

3.6

4.2

4.8

5.4

l/min

0

5

10

15

20

25

30

35

40

50

60

70

80

90

PKm 60®

PK 60®

0.37

0.50

40

38

33.5

29

24

19.5

15

10

5

PKm 65

PK 65

0.50

0.70

55

50

45.5

40.5

36

31

27

22

17

PKm 70

PK 70

0.60

0.85

65

62

57

52

47

42

37

32

27

18

PKm 80

PK 80

0.75

1

70

66

61

56

51

46

41

36.5

31

22

PKm 90

PK 90

0.75

1

90

82

71

60

49

38

27

17

5

PKm 100

PK 100

1.1

1.5

85

80

75

70

65

60

55

50

45

35

25

15

PKm 200

PK 200

1.5

2

90

86

81

76

71

65.5

60

55

50

40

30

20

10

PK 300

2.2

3

100

95

90

85

80

75

70

65

60

50

40

30

20

H metres

Q = Flow rate H = Total manometric head HS = Suction height

8

10

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

17


PK POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

MOTOR BRACKET

Aluminium with brass insert (patented), reduces the risk of impeller seizure

3

IMPELLER

Brass, with peripheral radial vanes

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

PK 60-65-70-80 PK 90 PK 100-200-300

AR-12 MG1-12 FN-14

Ø 12 mm Ø 12 mm Ø 14 mm

Pump

Model

PK 60-65 PK 70-80-90 PK 100-200-300

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ

Pump

Capacitance

6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Silicon carbide Graphite

Graphite Graphite Ceramic

NBR NBR NBR

Single-phase

(230 V or 240 V)

(110 V)

PKm 60 PKm 65 PKm 70 PKm 80 PKm 90 PKm 100 PKm 200

10 μF 450 VL 14 μF 450 VL 16 μF 450 VL 20 μF 450 VL 20 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL

25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL

PKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PK: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

7

6

1

18

3

5

2

6

4

8


DIMENSIONS AND WEIGHT f

i

h1

DN1

h3

h

h2

DN2

s a

MODEL

w

n1 n

m

PORTS

Single-phase

Three-phase

PKm 60®

PK 60®

PKm 65

PK 65

PKm 70

PK 70

PKm 80

PK 80

PKm 90

PK 90

PKm 100

PK 100

PKm 200

PK 200

PK 300

DN1

DIMENSIONS mm

DN2

a 39

1”

¾” 1”

1”

¾” 1”

f

h

h1

207

145

56

232

152

63

55

285

46

278

55

350

180

212

h2

h3

75

71

80

i

131

m

n

55

138

85

156

84

155

94

kg

174

20

n1

118

80

93-100 100

w

s

53 7

90

140

112

62

19 20

100

164

125

85

9

1~

3~

5.2

5.2

6.6

6.1

10.0

9.9

10.0

9.9

10.3

10.0

14.4

12.4

15.5

13.4

15.6

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

PKm 60®

2.5 A

2.4 A

5.5 A

PKm 65

3.7 A

3.4 A

7.4 A

PKm 70

5.2 A

4.8 A

10.8 A

PKm 80

5.2 A

4.8 A

10.8 A

PKm 90

5.6 A

5.1 A

11.5 A

PKm 100

9.0 A

8.2 A

18.0 A

PKm 200

11.5 A

11.0 A

24.0 A

PK 60® PK 65 PK 70 PK 80 PK 90 PK 100 PK 200 PK 300

2.0 A 3.0 A 3.8 A 3.8 A 4.0 A 6.2 A 7.6 A 9.3 A

1.15 A 1.7 A 2.2 A 2.2 A 2.3 A 3.6 A 4.4 A 5.4 A

– – – – – 2.05 A 2.5 A 3.15 A

1.9 A 2.8 A 3.3 A 3.3 A 3.8 A 5.7 A 7.0 A 8.7 A

1.1 A 1.6 A 1.9 A 1.9 A 2.2 A 3.3 A 4.0 A 5.0 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

3~

n° pumps

1489

1272

1272

330

1271

PKm 60®

PK 60®

240

PKm 65

PK 65

189

1352

1177

PKm 70

PK 70

102

1280 1044 1034

PKm 80

PK 80

102

PKm 90

PK 90

PKm 100

PK 100

PKm 200 –

H (mm)

kg 1~

3~

2009 1740

1740

243

1715

1628

1506

170

2040 1724

1707

1280 1044 1034

170

2040 1724

1707

102

1280

170

2040 1775

1724

72

1520 1060

910

84

1750

1230 1060

PK 200

72

1520

1140

990

84

1750

1320

1150

PK 300

72

1520

1140

84

1750

1330

1075 1044

H

0

Three-phase

80

Single-phase

00

12

19


PKS Self-priming pumps with peripheral impeller

PERFORMANCE RANGE

•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 70 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +60 °C •• Ambient temperature up to +40 °C (+45 °C for PKS 60) •• Max. working pressure 6.5 bar •• Continuous service S1

INSTALLATION AND USE Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their compactness, reliability and the fact that they are easy to use, they are suitable for use in domestic applications such as the distribution of water in combination with small pressure sets, for the irrigation of gardens and allotments, for drawing water from tanks and for all those other situations where air or water may be present in the water to be pumped. The pump comes complete with a flap-check valve. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

PATENTS - TRADE MARKS - MODELS

•• Motor bracket: patent n° IT1243605 •• Registered Italian model n° 72753

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for PKS 70, PKS 80

GUARANTEE 1 year subject to terms and conditions

20


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

PKS 80 PKS 70

Head H (metres) 4

PKS 65

PKS 60

Flow rate Q 4 MODEL

POWER

Single-phase Three-phase

kW

HP

PKSm 60

PKS 60

0.37

0.50

PKSm 65

PKS 65

0.50

0.70

PKSm 70

PKS 70

0.60

0.85

PKSm 80

PKS 80

0.75

1

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

3.0

l/min

0

5

10

15

20

25

30

35

40

45

50

40

38

33.5

29

24

19.5

15

10

5

55

50

45.5

40.5

36

31

27

22

17

12.5

8

65

62

57

52

47

42

37

32

27

22

18

70

66

61

56

51

46

41

36.5

31

27

22

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

HS = Suction height

21


PKS POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1 and the suction port with built-in flap-check valve

2

MOTOR BRACKET

Aluminium with brass insert (patented), reduces the risk of impeller seizure

3

IMPELLER

Brass, with peripheral radial vanes

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-12

Ø 12 mm

6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

Pump

Model

PKS 60-65 PKS 70-80

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

PKSm 60 PKSm 65 PKSm 70 PKSm 80

10 μF 450 VL 14 μF 450 VL 16 μF 450 VL 20 μF 450 VL

25 μF 250 VL 25 μF 250 VL 60 μF 250 VL 60 μF 250 VL

PKSm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PKS: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

22

3

5

2

7

4

6

8


DIMENSIONS AND WEIGHT f

n DN2

h1

h

DN1

h2

i

s a

w

MODEL

m

n1

PORTS DN1

DIMENSIONS mm

DN2

Single-phase

Three-phase

PKSm 60

PKS 60

PKSm 65

PKS 65

PKSm 70

PKS 70

PKSm 80

PKS 80

260

1”

1”

a

f

29

h

h1

h2

i

197

183

149

55

222

190

156

80

198

164

34

110

m

90

kg n 149 160

n1

w

93-100 100 112

s

53 7 62

1~

3~

6.1

6.1

7.4

6.9

10.6

9.7

10.6

9.7

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

PKSm 60

2.5 A

2.4 A

5.5 A

PKS 60

2.0 A

1.15 A

1.9 A

415 V 1.1 A

PKSm 65

3.7 A

3.4 A

7.4 A

PKS 65

3.0 A

1.7 A

2.8 A

1.6 A

PKSm 70

5.2 A

4.8 A

10.8 A

PKS 70

3.8 A

2.2 A

3.3 A

1.9 A

PKSm 80

5.2 A

4.8 A

10.8 A

PKS 80

3.8 A

2.2 A

3.3 A

1.9 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

1~

3~

PKS 60

210

1569

1305

1305

270

1994

1671

1671

PKS 65

150

1150

1134

1059

210

1564

1578

1473

Single-phase

Three-phase

PKSm 60 PKSm 65 PKSm 70

PKS 70

105

1300

1130

1040

168

1980 1800 1650

PKSm 80

PKS 80

105

1300

1130

1040

168

1980 1800 1650

H

0 80

00

12

23


PQ Pumps with peripheral impeller

PERFORMANCE RANGE

•• Flow rate up to 90 l/min (5.4 m³/h) •• Head up to 100 m

APPLICATION LIMITS

•• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C

INSTALLATION AND USE Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. The hydraulic characteristics of these pumps, coupled with their compactness, makes them suitable for use in both domestic and industrial applications. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

(+45 °C for PQ 60, PQ 60-Bs)

•• Max. working pressure:

– 6.5 bar for PQ 60-65 – 10 bar for PQ 70-80-81-90-100-200-300 •• Continuous service S1

PATENTS - TRADE MARKS - MODELS

•• Registered model PQm60 n° 0001520591 •• Motor bracket: patent n° IT1243605 •• Registered Community Design n° 002146548

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

24

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency •• IP X5 class protection for PQ 70-80-90-100-200-300

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

PQ300 PQ200

Head H (metres) 4

PQ90

PQ80 PQ70

PQ65

PQ60

PQ100 PQ81

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

3.0

3.6

4.2

4.8

5.4

l/min

0

5

10

15

20

25

30

35

40

50

60

70

80

90

PQm 60®

PQ 60®

0.37

0.50

40

38

33.5

29

24

19.5

15

10

5

PQm 65

PQ 65

0.50

0.70

55

50

45.5

40.5

36

31

27

22

17

PQm 70

PQ 70

0.60

0.85

65

62

57

52

47

42

37

32

27

18

PQm 80

PQ 80

0.75

1

70

66

61

56

51

46

41

36.5

31

22

PQm 90

PQ 90

0.75

1

PQm 100

PQ 100

1.1

1.5

PQm 200

PQ 200

1.5

PQ 300

PQm 60-Bs PQm 65-Bs

90

8

H metres 85

82

71

60

49

38

27

17

5

80

75

70

65

60

55

50

45

35

25

15

2

90

86

81

76

71

65.5

60

55

50

40

30

20

10

2.2

3

100

95

90

85

80

75

70

65

60

50

40

30

20

PQ 60-Bs

0.37

0.50

40

38

33.5

29

24

19.5

15

10

5

PQ 65-Bs

0.50

0.70

55

50

45.5

40.5

36

31

27

22

17

10

8

➠ Bs= version with brass pump body

MODEL Single-phase Three-phase

POWER kW

HP

PQm 81

PQ 81

0.50

0.70

PQm 81-Bs

PQ 81-Bs

0.50

0.70

Q

m³/h

0

0.12

0.24

0.36

0.48

0.60

0.72

0.84

0.96

1.08

l/min

0

2

4

6

8

10

12

14

16

18

90

80

71

63

54

45

37

28

19

10

90

80

71

63

54

45

37

28

19

10

H metres

➠ Bs= version with brass pump body Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

25


PQ POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron (brass for PQ-Bs), complete with threaded ports in compliance with ISO 228/1

2

MOTOR BRACKET

Aluminium with brass insert (patented), reduces the risk of impeller seizure

3

IMPELLER

Brass, with peripheral radial vanes

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

PQ 60-65 PQ 70-80-81-90 PQ 60Bs-65Bs-81Bs PQ 100-200-300

AR-12

Pump

Model

6

BEARINGS

PQ 60-65-81 PQ 60Bs-65Bs-81Bs PQ 70-80-90 PQ 100-200-300 7

8

CAPACITOR

Rotational ring

Elastomer

Ø 12 mm

Ceramic

Graphite

NBR

MG1-12

Ø 12 mm

Silicon carbide

Graphite

NBR

FN-14

Ø 14 mm

Graphite

Ceramic

NBR

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ

Pump

ELECTRIC MOTOR

Materials Stationary ring

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

PQm 60 - 60Bs PQm 65 - 65Bs PQm 70 PQm 80 PQm 81 - 81Bs PQm 90 PQm 100 PQm 200

10 μF 450 VL 14 μF 450 VL 16 μF 450 VL 20 μF 450 VL 14 μF 450 VL 20 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL

25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL 25 μF 250 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL

PQm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PQ: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

26

3

5

7

2

4

6

8


DIMENSIONS AND WEIGHT i

f

h1

h3

h

DN1

h2

DN2

s a

MODEL Single-phase

PORTS

Three-phase

PQm 60®

PQ 60®

PQm 60-Bs

PQ 60-Bs

PQm 65

PQ 65

PQm 65-Bs PQm 70 PQm 80 PQm 81 PQm 81-Bs PQm 90 PQm 100 PQm 200 –

PQ 65-Bs PQ 70 PQ 80 PQ 81 PQ 81-Bs PQ 90 PQ 100 PQ 200 PQ 300

n1 n

m

w

DN1

1”

DIMENSIONS mm

DN2

1”

a

22

f

h

h1

190

145

101 113

h2

30

kg

h3

i

m

n

n1

131

76

55

118

93-100

143

78

216

152

108

138

76

255

180

121

151

w

s

1~ 5.1

5.1

5.4

5.4

6.4

5.9

6.7 9.7 9.7 6.6 6.5 9.9 14.1 15.2 –

6.2 9.0 9.0 6.2 6.1 8.8 12.2 14.1 15.2

53 80

120

100

83

90

138

112

62

7

½”

½”

18

214

152

119

22

141

71

80

120

100

56

¾”

¾”

22

255

180

126

27

153

84

90

138

112

62

1”

1”

25

318

212

140

30

170

89

100

164

125

85

9

3~

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

PQm 60® – PQm 60-Bs PQm 65 – PQm 65-Bs PQm 70 PQm 80 PQm 81 – PQm 81-Bs PQm 90 PQm 100 PQm 200

2.6 A 3.7 A 5.2 A 5.2 A 3.4 A 5.6 A 9.0 A 12.0 A

2.4 A 3.4 A 4.8 A 4.8 A 2.7 A 5.1 A 8.2 A 11.0 A

5.2 A 7.4 A 10.8 A 10.8 A 5.8 A 11.5 A 18.0 A 24.0 A

PQ 60® – PQ 60-Bs PQ 65 – PQ 65-Bs PQ 70 PQ 80 PQ 81 – PQ 81-Bs PQ 90 PQ 100 PQ 200 PQ 300

2.0 A 3.0 A 3.8 A 3.8 A 2.2 A 4.2 A 6.3 A 7.6 A 9.3 A

1.15 A 1.7 A 2.2 A 2.2 A 1.3 A 2.4 A 3.6 A 4.4 A 5.4 A

– – – – – – 2.05 A 2.5 A 3.15 A

1.9 A 2.8 A 3.3 A 3.3 A 2.0 A 3.8 A 5.7 A 7.0 A 8.7 A

1.1 A 1.6 A 1.9 A 1.9 A 1.15 A 2.2 A 3.3 A 4.0 A 5.0 A

PALLETIZATION MODEL Three-phase PQ 60® PQ 60-Bs PQ 65 PQ 65-Bs PQ 70 PQ 80 PQ 81 PQ 81-Bs PQ 90 PQ 100 PQ 200 PQ 300

H (mm) 1465 1240 1484 1484 1280 1280 1484 1484 1280 1510 1510 1510

CONTAINER kg

1~ 1330 1309 1407 1471 1013 1013 1450 1428 1034 1040 1120 –

3~ 1330 1309 1299 1363 942 942 1363 1342 922 900 1040 1120

n° pumps 352 306 270 243 170 170 270 270 170 96 96 96

H (mm) 1976 1563 1790 1625 2040 2040 1790 1790 2040 1970 1970 1970

kg 1~ 3~ 1819 1819 1676 1676 1752 1617 1652 1531 1673 1554 1673 1554 1806 1698 1779 1671 1707 1520 1380 1190 1480 1380 – 1480

H

0 80

Single-phase PQm 60® PQm 60-Bs PQm 65 PQm 65-Bs PQm 70 PQm 80 PQm 81 PQm 81-Bs PQm 90 PQm 100 PQm 200 –

GROUPAGE n° pumps 256 238 216 216 102 102 216 216 102 72 72 72

00

12

27


PQ 3000 Pump with peripheral impeller

PERFORMANCE RANGE

•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 180 m

APPLICATION LIMITS

•• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 18 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The hydraulic characteristics of this pump, coupled with its compactness, make it suitable for use in the industrial applications. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• Motor bracket: patent n° IT1243605

OPTIONALS AVAILABLE ON REQUEST

EN 60034-1 IEC 60034-1 CEI 2-3

•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency

CERTIFICATIONS

GUARANTEE

COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

28

1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

Head H (metres) 4

PQ3000

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

PQ 3000

2.2

3

Q

m³/h

0

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

3.0

l/min

0

10

15

20

25

30

35

40

45

50

180

160

145

132

118

105

92

78

63.5

50

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

29


PQ 3000 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY PLATE

Stainless steel AISI 316

3

MOTOR BRACKET

Aluminium, with brass insert and stainless steel shim disc that reduces the risk of impeller seizure

4

IMPELLER

Bronze, with peripheral radial vanes

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

FN-18 NU

Ø 18 mm

Materials Stationary ring

Rotational ring

Elastomer

Graphite

Ceramic

NBR

7

BEARINGS

6204 ZZ - C3 / 6204 ZZ - C3

8

ELECTRIC MOTOR

PQ 3000: three-phase 230/400 V - 50 Hz. ➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: H class.   – Protection: IP X5.

1

2

30

7

4

3

7

6

5

8


DIMENSIONS AND WEIGHT i

f

h1

h3

h

DN1

h2

DN2

s a

MODEL Three-phase PQ 3000

w

n1

m

n

PORTS

DIMENSIONS mm

kg

DN1

DN2

a

f

h

h1

h2

h3

i

m

n

n1

w

s

3~

¾”

¾”

34

329

212

142

38

180

65

100

164

125

97

9

18.4

ABSORPTION MODEL

VOLTAGE (three-phase)

Three-phase

230 V

400 V

240 V

415 V

PQ 3000

11.5 A

6.6 A

10.8 A

6.2 A

PALLETIZATION MODEL

PQ 3000

GROUPAGE n° pumps

H (mm)

72

1840

CONTAINER kg

n° pumps

H (mm)

kg

1352

84

2114

1567

H

0 80

00

12

31


PV Pump with peripheral impeller

PERFORMANCE RANGE

•• Flow rate up to 10 l/min (0.6 m³/h) •• 50 Hz: head up to 42 m •• 60 Hz: head up to 55 m

APPLICATION LIMITS

•• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +45 °C •• Max. working pressure 10 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The design of this particularly compact brass pump offers an effective guarantee against the formation of rust and oxidation; as a result they are recommended for use in industrial applications such as cooling and conditioning. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• Motor bracket: patented n° IT1243605

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

32

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50/60 Hz  n= 2900/3450 1/min  HS= 0 m

0.5 60

0

1.5 0.5

2

1

2.5

1.5

2

55

180

50

160 PV55 - 60Hz

45

Head H (metres) 4

140 40 120

PV55 - 50Hz

35 30

100

25

80

20

60

15 40 10 20

5

0

0

1

0

2

3

0.1

MODEL

PVm 55

PV 55

5

0.2

POWER

Single-phase Three-phase

4

kW

HP

0.18

0.25

Q H

metres

6

0.3

Flow rate Q 4

7

8

0.4

9

0

10

0.5

0.6

m³/h

0

0.12

0.18

0.24

0.30

0.36

0.42

0.48

0.54

0.60

l/min

0

2

3

4

5

6

7

8

9

10

50 Hz

42

35

31

27.5

24

20.5

16

12.5

9

5

60 Hz

55

46

41.5

37

32.5

28

23.5

19

14.5

10

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

➠ The PV 55 pump is designed to work at 50 Hz and 60 Hz (see the characteristic curves)

33


PV POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Brass, with threaded ports in compliance with ISO 228/1

2

PUMP BODY BACK-PLATE

Brass

3

MOTOR BRACKET

Aluminium

4

IMPELLER

Brass, with peripheral radial vanes

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

MG1-12E

Ø 12 mm

7

BEARINGS

6201 ZZ / 6201 ZZ

8

CAPACITOR

Capacitance

9

Materials Stationary ring

Rotational ring

Elastomer

Silicon carbide

Graphite

EPDM

230÷240 V (50÷60 Hz)

110 V (50÷60 Hz)

10 μF 450 VL

25 μF 250 VL

PVm: single-phase 230 V - 50÷60 Hz with thermal overload protector built-in to the winding. PV: three-phase 230/400 V - 50÷60 Hz.

ELECTRIC MOTOR

➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

34

4

7

2

8

3

5

7

9


DIMENSIONS AND WEIGHT 90°

i DN1

f

h

h2

DN2

h1

h3

180°

s a

w

n1 n

m

90°

When rotating the pump body it is also necessary to rotate the pump body back-plate

MODEL Single-phase

Three-phase

PVm 55

PV 55

PORTS

DIMENSIONS mm

kg

DN1

DN2

a

f

h

h1

h2

h3

i

m

n

n1

w

s

1~

3~

¼”

¼”

11

188

145

56

40

96

25

55

118

93-100

63

7

4.5

4.5

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

PVm 55 (50Hz)

1.6 A

1.5 A

3.2 A

PV 55 (50÷60Hz)

1.7 A

1.0 A

PVm 55 (60Hz)

2.0 A

1.9 A

4.0 A

PALLETIZATION MODEL Single-phase

Three-phase

PVm 55

PV 55

GROUPAGE n° pumps

H (mm)

238

1240

CONTAINER kg

1~

3~

1095 1095

kg

n° pumps

H (mm)

1~

3~

306

1563

1401

1401

H

0 80

00

12

35


PQA Pumps with peripheral impeller

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. The RYTON and brass pump body construction guarantees against the formation of rust and oxidation. As a result of these characteristics these pumps are suitable for use in industrial applications such as cooling, conditioning and boiler feed. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 45 l/min (2.7 m³/h) •• Head up to 90 m •• Manometric suction lift up to 8 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C (+45 °C for PQA 60)

•• Max. working pressure 10 bar •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

36

PATENTS - TRADE MARKS - MODELS

•• Motor bracket: patented n° IT1243605

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency •• IP X5 class protection for PQA 70-72-80-82-90

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

PQA90

PQA80

Head H (metres) 4

PQA70

PQA60

PQA82 PQA72

Flow rate Q 4

MODEL Single-phase Three-phase PQAm 60 PQA 60 PQAm 70 PQA 70 PQAm 72 PQA 72 PQAm 80 PQA 80 PQAm 82 PQA 82 PQAm 90 PQA 90

POWER kW 0.37 0.55 0.55 0.75 0.75 0.75

HP 0.50 0.75 0.75 1 1 1

Q

m³/h

0

0.1

0.3

0.6

0.9

1.2

1.5

1.8

1.9

2.3

2.7

3.0

l/min

0

2

5

10

15

20

25

30

32

38

45

50

40

38

35

29

23.5

18

12.5

7

5

65

62

58

52

45.5

39.5

33

27

24

16.5

8

65

-

62

57

52

47

42

37.5

35.5

29.5

22.5

70

66

62

56

49.5

43

37

31

28

20.5

12

70

-

66

61

56

51

46

41.5

39.5

34

26.5

90

86

79

68

56.5

45.5

34

23

18.5

5

H metres

Q = Flow rate H = Total manometric head HS = Suction height

18 22

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

37


PQA POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

RYTON, complete with threaded metallic port inserts in compliance with ISO 228/1

2

BODY PLATE

Brass

3

MOTOR BRACKET

Aluminium with brass insert (patented), reduces the risk of impeller seizure

4

IMPELLER

Brass, with peripheral radial vanes

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

MG1-12

Ø 12 mm

7

8

9

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Silicon carbide

Graphite

NBR

Pump

Model

PQA 60 PQA 70-72-80-82-90

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

PQAm 60 PQAm 70-72 PQAm 80-82 PQAm 90

10 μF 450 VL 16 μF 450 VL 20 μF 450 VL 20 μF 450 VL

25 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL

PQAm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PQA: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

1

2

38

7

4

3

7

8

6

5

9


DIMENSIONS AND WEIGHT i

f

h1

h3

h

DN1

h2

DN2

s a

MODEL

n1

m

w

n

PORTS

Single-phase

Three-phase

PQAm 60

PQA 60

PQAm 70

PQA 70

DIMENSIONS mm

DN1

DN2

½”

½”

PQAm 72

PQA 72

1”

1”

PQAm 80

PQA 80

½”

½”

PQAm 82

PQA 82

1”

1”

PQAm 90

PQA 90

½”

½”

a

f

h

25

192

145

28

258

179

h1

h2

h3

i

96

33

129

116.5

32.5

149

72.5

kg m

n

n1

w

55

118

93-100

53

s

1~

3~

4.7

4.7

9.4

8.4

9.5

8.5

9.4

8.4

121

30

151

83

116.5

32.5

149

72.5

30

151

83

9.5

8.5

35

156

76

9.5

8.5

121

90

138

112

7

62

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

VOLTAGE (three-phase)

110 V

Three-phase

230 V

400 V

240 V

415 V

PQAm 60

2.5 A

2.4 A

5.2 A

PQA 60

2.0 A

1.15 A

1.9 A

1.1 A

PQAm 70

6.2 A

5.5 A

10.8 A

PQA 70

4.2 A

2.4 A

3.7 A

2.2 A

PQAm 72

6.2 A

5.5 A

10.8 A

PQA 72

4.2 A

2.4 A

3.7 A

2.2 A

PQAm 80

6.3 A

5.5 A

10.8 A

PQA 80

4.2 A

2.4 A

3.7 A

2.2 A

PQAm 82

6.3 A

5.5 A

10.8 A

PQA 82

4.2 A

2.4 A

3.7 A

2.2 A

PQAm 90

5.6 A

5.1 A

11.5 A

PQA 90

4.2 A

2.4 A

3.8 A

2.2 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

kg

Single-phase

Three-phase

1~

PQAm 60

PQA 60

238

1240

1143

1143

306

1563

3~

PQAm 70

PQA 70

102

1280

983

881

170

2040 1622

1452

PQAm 72

PQA 72

120

1310

1160

1040

180

1900 1730

1550

PQAm 80

PQA 80

102

1280

983

881

170

2040 1622

1452

PQAm 82

PQA 82

120

1310

1160

1040

180

1900 1730

1550

PQAm 90

PQA 90

102

1280

993

891

170

2040 1639

1469

1462 1462

H

0 80

00

12

39


CP Centrifugal pumps

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their reliability and the fact that they are easy to use, these pumps are widely used in domestic and civil applications such as the distribution of water in combination with small and medium sized pressure sets, for transferring liquids and for the irrigation of gardens and allotments. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 160 l/min (9.6 m³/h) •• Head up to 56 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature up to +40 °C •• Max. working pressure:

– 6 bar for CP 100-130-132-150-158 – 10 bar for CP 170-190-200 •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

REGULATION (EU) N. 547/2012

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

40

PATENTS - TRADE MARKS - MODELS

•• Registered model CPm158 n° 0001516350 •• Registered Community Design nº 002098434 OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for CP 170, CP 170M

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

Head H (metres) 4

η = 38.5% η = 32%

η = 41%

η = 43% η = 34% η = 45.5%

η = 38%

η = 53.5%

η = 41%

Flow rate Q 4

MODEL Single-phase Three-phase CPm 100 – CPm 130 CP 130 CPm 132A CP 132A CPm 150 CP 150 CPm 158® CP 158® CPm 170 CP 170 CPm 170M CP 170M CPm 190 CP 190 – CP 200

POWER kW 0.25 0.37 0.60 0.75 0.75 1.1 1.1 1.5 2.2

HP 0.33 0.50 0.85 1 1 1.5 1.5 2 3

m³/h

0

0.6

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

l/min

0

10

20

30

40

50

60

70

80

90

100 110 120 130 140 150 160

16

15

14

12.5

11

9

7

23

22

21

20

19

18

17

15.5

14

23

22

21.5

21

20

19

18

17

16

14

12

9

29.5

29

28.5

28

26

24.5

23

21

18

15

H metres 36

34

33.5

33

41

38

36

35

34.5 33.5

48

46

44.5

56

55

54.5 53.5

Q

Q = Flow rate H = Total manometric head HS = Suction height

27.5 26.5

32.5 31.5 37

36 43

6.6

7.2

7.8

8.4

30

28.5

27

25

35

33.5

32

30

27.5

25

22

33

32

31

30

29

28

26.5

25

23

41.5

40

38

36

34.5 32.5 30.5

28

26

52

51

49.5

48

46

44.5 42.5 40.5 38.5

9.0

21

9.6

19

36

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

41


CP POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304 (cast iron for CP 170-170M-190-200)

3

IMPELLER

Stainless steel AISI 304

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

CP 100-130-132A CP 150-158 CP 170-170M-190-200

AR-12 AR-14 FN-18

Ø 12 mm Ø 14 mm Ø 18 mm

Pump

Model

CP 100-130-132A CP 150-158 CP 170-170M CP 190-200

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ 6304 ZZ / 6204 ZZ

Pump

Capacitance

6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Ceramic Graphite

Graphite Graphite Ceramic

NBR NBR NBR

Single-phase

(230 V or 240 V)

(110 V)

CPm 100 CPm 130 CPm 132A CPm 150-158 CPm 170-170M CPm 190

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL 20 μF 450 VL 25 μF 450 VL 45 μF 450 VL

25 μF 250 VL 25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL

CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CP: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

42

3

2

5

6

7

4

8


DIMENSIONS AND WEIGHT f

n

DN2

h1

DN1

h

h2

a

s

w n1

MODEL

PORTS

Single-phase

Three-phase

CPm 100 CPm 130 CPm 132A CPm 150 CPm 158® CPm 170 - 170M CPm 190 –

– CP 130 CP 132A CP 150 CP 158® CP 170 - 170M CP 190 CP 200

DN1

DIMENSIONS mm

DN2

a

f

h

253 1”

1¼”

1”

h1

205

82

h2 123

n 165

kg n1

w

135

41

42

1”

s

10 285

240

92

148

190

160

38

51

367

260

110

150

206

165

44.5

48

364

290

115

175

242

206

36.5

11

1~

3~

6.9 7.6 8.3 12.4 12.0 17.8 21.3 –

– 7.1 8.0 11.4 11.0 17.2 20.3 21.5

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

CPm 100 CPm 130 CPm 132A CPm 150 CPm 158® CPm 170 - 170M CPm 190

1.9 A 3.2 A 3.5 A 5.7 A 6.0 A 7.8 A 11.0 A

1.55 A 2.9 A 3.2 A 5.4 A 5.8 A 7.2 A 10.0 A

3.3 A 6.4 A 7.0 A 11.4 A 12.0 A 16.0 A 22.0 A

CP 130 CP 132A CP 150 CP 158® CP 170 - 170M CP 190 CP 200

2.0 A 2.9 A 4.2 A 4.4 A 5.2 A 7.5 A 9.3 A

1.2 A 1.7 A 2.4 A 2.5 A 3.0 A 4.3 A 5.4 A

1.8 A 2.4 A 4.1 A 4.3 A 5.1 A 7.3 A 9.0 A

1.1 A 1.4 A 2.4 A 2.5 A 2.9 A 4.2 A 5.2 A

PALLETIZATION MODEL

105 105 105 70 70 50 50 36 36

1280 1280 1280 1450 1450 1560 1560 1410 1410

CONTAINER kg

1~ 741 820 890 890 860 900 940 784 –

3~ – 770 860 820 790 870 910 754 794

n° pumps

H (mm)

189 189 189 112 112 70 70 54 54

2190 2190 2190 2240 2240 2120 2120 2040 2040

kg 1~ 3~ 1321 – 1460 1360 1590 1530 1410 1300 1360 1250 1250 1200 1310 1260 1166 1116 – 1186

H

0

Three-phase – CP 130 CP 132A CP 150 CP 158® CP 170 CP 170M CP 190 CP 200

H (mm)

80

Single-phase CPm 100 CPm 130 CPm 132A CPm 150 CPm 158® CPm 170 CPm 170M CPm 190 –

GROUPAGE n° pumps

00

12

43


CP Centrifugal pumps

PERFORMANCE RANGE

•• Flow rate up to 900 l/min (54 m³/h) •• Head up to 74 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 10 bar •• Continuous service S1

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their reliability and the fact that they are easy to use, these pumps are widely used in civil, agricultural and industrial applications such as for supplying water, in conditioning and cooling systems, for irrigation, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

CONSTRUCTION AND SAFETY STANDARDS

•• Registered Community Design n° 002098434 for CP 160, CP210 •• Registered Italian model n° 72753 for CP 220, CP 230, CP250

EN 60034-1 IEC 60034-1 CEI 2-3

OPTIONALS AVAILABLE ON REQUEST

REGULATION (EU) N. 547/2012

•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft for CP 220,

CERTIFICATIONS

•• Other voltages or 60 Hz frequency •• IP X5 class protection for CP 160

CP 230, CP250

COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

GUARANTEE 1 year subject to terms and conditions

44


PERFORMANCE RANGE

50 Hz  n= 2900 1/min  HS= 0 m

Head H (metres) 4

CP 210

CP 160

CP 250

CP 220

CP 230

Flow rate Q 4

45


CP 160-210 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

20

30

10

40

20

50

30

70

50

US g.p.m. 60

Imp g.p.m. feet

CP210A

60

200 42 46

48

49

CP210B

Head H (metres) 4

60

40

50

50

51

η = 52% 150

CP210C

51

CP160A

50

40

52

H (feet)

70

10

0

50 Hz  n= 2900 1/min  HS= 0 m

54

CP160B

50

56

CP160C

30

100 η = 57% 56

20 50

CP210

12 10

3

8

2

6

1

4

0 4

0

2

CP210A CP210B

3

3

CP160A CP160C

CP160B

2

1

0

5 4

CP210C

2

NPSH (feet)

14

CP160

4

P2 (HP)

Absorbed power P2 (kW)

NPSH (metres)

10

1

0

50

100

0

150

200

5

l/min

250

10

0

m³/h

15

Flow rate Q 4

MODEL Single-phase CPm 160C CPm 160B – CPm 210C – –

Three-phase CP 160C CP 160B CP 160A CP 210C CP 210B CP 210A

POWER kW 1.1 1.5 2.2 2.2 3 4

HP 1.5 2 3 3 4 5.5

Q

m³/h

0

3

4.5

6

7.5

9

10.5

12

13.2

14.4

15

16.2

16.8

l/min

0

50

75

100

125

150

175

200

220

240

250

270

280

32

31

30.5

29.5

28

26

23

20

37

36

35.5

34.5

33.5

31.5

29

26.5

23

43

42

41.5

40.5

39.5

38

35.5

33

30

26

46

45.5

44.5

43.5

42

40

37.5

34.5

32

28.5

54

53

52

51

49.5

48

45.5

43

40

38.5

37

34

61

61

60

59

57.5

56

53.5

51

49

46.5

45

42

H metres

Q = Flow rate H = Total manometric head HS = Suction height

46

27 40

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


CP 220 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

CP220AH CP220A

η

Head H (metres) 4

59

H (feet)

CP220B

Absorbed power P2 (kW)

NPSH (feet)

NPSH (metres)

CP220C

AH

P2 (HP)

A

B C

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

3

6

12

18

24

27

l/min

0

50

100

200

300

400

450

CPm 220C

CP 220C

2.2

3

32

31.5

31

30

28

24

21

CP 220B

3

4

38

37.5

37

36

33.5

29

25

CP 220A

4

5.5

49

48.5

48

46

43.5

39.5

36

CP 220AH

5.5

7.5

52

51.5

51

49

47

44

42

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

47


CP 230 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

64

Head H (metres) 4

η = 65%

P2 (HP)

Absorbed power P2 (kW)

NPSH (feet)

NPSH (metres)

H (feet)

64

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

CP 230C

3

4

CP 230B

4

5.5

CP 230A

5.5

7.5

Q

m³/h

0

6

12

18

24

30

36

42

48

51

54

l/min

0

100

200

300

400

500

600

700

800

850

900

30

29.5

28.5

27

25

22

19.5

15.5

11.5

9

39

38.5

38

36

34

31

28

24

18.5

15

13

46

45.5

44.5

42

40

37

32.5

27.5

21.5

18

15

H metres

Q = Flow rate H = Total manometric head HS = Suction height

48

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


CP 250 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

46 51

Head H (metres) 4

52

H (feet)

η = 54% 52

P2 (HP)

Absorbed power P2 (kW)

NPSH (feet)

NPSH (metres)

51

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

CP 250C

7.5

10

CP 250A

11

15

Q

m³/h

0

6

12

18

24

30

36

42

48

54

l/min

0

100

200

300

400

500

600

700

800

900

57

56

54.5

52.5

49.5

46

41.5

35.5

30

24

74

73

71

68

65

61

57

51

45

37

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

49


CP 160-210 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Cast iron

3

IMPELLER

Brass

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

CP 160 CP 210

FN-18 FN-24

Ø 18 mm Ø 24 mm

Pump

Model

CP 160 CP 210

6204 ZZ / 6204 ZZ 6206 ZZ - C3 / 6205 ZZ

Pump

Capacitance

6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Graphite Graphite

Ceramic Ceramic

NBR NBR

Single-phase

(230 V or 240 V)

(110 V)

CPm 160C CPm 160B CPm 210C

31.5 μF 450 VL 45 μF 450 VL 70 μF 450 VL

60 μF 250 VL 80 μF 250 VL –

CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding (up to 1.5 kW). CP: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

50

3

2

7

5

4

8

6


DIMENSIONS AND WEIGHT f

n

DN2

h1

DN1

h

h2

a

s

w n1

MODEL

PORTS

Single-phase

Three-phase

CPm 160C

CP 160C

CPm 160B

CP 160B

CP 160A

CPm 210C

CP 210C

CP 210B

CP 210A

DN1

DIMENSIONS mm

DN2

a

f

54 1½”

h

373

h1

260

h2

110

150

n

207

kg n1

w

165

s

44.5

11

1” 60

402

305

125

180

252

210

39.5

11

1~

3~

19.7

17.7

21.0

21.0

21.0

26.0

27.5

30.0

32.0

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

CPm 160C

8.6 A

7.8 A

17.0 A

CP 160C

5.7 A

3.3 A

1.9 A

5.2 A

3.0 A

1.7 A

CPm 160B

10.3 A

9.8 A

21.0 A

CP 160B

7.3 A

4.2 A

2.4 A

6.7 A

3.9 A

2.3 A

CPm 210C

13.0 A

12.7 A

CP 160A

8.9 A

5.1 A

3.0 A

8.3 A

4.8 A

2.8 A

CP 210C

9.2 A

5.3 A

3.1 A

8.8 A

5.1 A

2.9 A

CP 210B

11.2 A

6.5 A

3.8 A

10.8 A

6.2 A

3.6 A

CP 210A

14.8 A

8.5 A

4.9 A

14.2 A

8.2 A

4.7 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

1~

CP 160C

50

1555

CP 160B

50

1555

CP 160A

50

CPm 210C

CP 210C

18

Single-phase

Three-phase

CPm 160C CPm 160B

CONTAINER kg

kg

3~

n° pumps

H (mm)

1~

3~

1009

909

70

2121

1403

1263

1074

1074

70

2121

1494 1494

1555

1074

70

2121

1494

1205

492

520

CP 210B

18

1205

564

CP 210A

18

1205

600

0 80

– –

H

00

12

51


CP 220-230-250 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Cast iron

3

IMPELLER

Brass for CP 220, CP 230 Cast iron for CP 250

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

FN-20

CP 220C-B CP 230C CP 220A-AH CP 230B-A CP 250C CP 250A 6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ø 20 mm

Graphite

Ceramic

NBR

FN-24

Ø 24 mm

Graphite

Ceramic

NBR

FN-32 NU

Ø 32 mm

Graphite

Ceramic

NBR

Pump

Model

CP 220C CPm 220C CP 220B CP 230C CP 220A-AH CP 230B-A CP 250C CP 250A

6206 ZZ - C3 / 6204 ZZ

Pump

Capacitance

6206 ZZ - C3 / 6205 ZZ 6307 ZZ - C3 / 6206 ZZ - C3 6310 ZZ - C3 / 6308 ZZ - C3

Single-phase

(230 V or 240 V)

CPm 220C

70 μF 450 VL

CPm: single-phase 230 V - 50 Hz. CP: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 11 kW. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X5.

6

1

52

3

2

7

5

4

8

6


DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w

n2

MODEL Single-phase

Three-phase

CPm 220C – – – – – – – –

CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250A

s

n1

PORTS DN1

DN2

DIMENSIONS mm a

f

70 2”

h

441/409 441 460 505 441 460 505 507 571

2”

65

h1

h2

n

kg n1

n2

315

132

183

255

170

230

328

136

192

273

190

250

315

132

183

255

170

230

328

136

192

273

190

250

392

160

232

322

230

294

w

s

1~

3~

14

31.9 – – – – – – – –

28.5 32.3 41.0 46.0 31.9 41.0 46.0 74.0 103.0

40

45

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

Three-phase

230 V

400 V

690 V

240 V

415 V

CPm 220C

15.8 A

15.0 A

CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250A

11.4 A 12.6 A 17.0 A 20.0 A 13.2 A 16.8 A 20.0 A 28.6 A 40.8 A

6.6 A 3.8 A 7.3 A 4.2 A 9.8 A 5.7 A 11.5 A 6.7 A 7.6 A 4.4 A 9.7 A 5.6 A 11.5A 6.7 A 16.5 A 9.5 A 23.6 A 13.7 A

10.7 A 12.0 A 16.5 A 21.0 A 11.1 A 16.2 A 19.2 A 27.5 A 40.8 A

6.2 A 3.6 A 7.0 A 4.0 A 9.5 A 5.5 A 12.0 A 6.9 A 6.4 A 3.7 A 9.4 A 5.4A 11.0 A 6.4 A 16.0 A 9.3 A 23.6 A 13.7 A

720 V

PALLETIZATION MODEL Three-phase CP 220C CP 220B CP 220A CP 220AH CP 230C CP 230B CP 230A CP 250C CP 250A

H (mm)

18 18 18 12 18 18 12 6 6

1220 1180 1430 1430 1200 1430 1430 1180 1180

CONTAINER kg

1~ 598 – – – – – – – –

3~ 530 608 760 570 598 760 570 460 640

n° pumps

H (mm)

24 24 24 16 24 24 16 – –

1580 1520 1860 1860 1550 1860 1860 – –

kg 1~ 790 – – – – – – – –

3~ 700 800 1000 760 790 1000 760 – –

H

0 80

Single-phase CPm 220C – – – – – – – –

GROUPAGE n° pumps

00

12

53


AL-RED Stainless steel centrifugal pump

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their construction characteristics, these centrifugal pumps are suitable for use in the domestic, agricultural and industrial sectors. All of the components in contact with the pumped liquid are constructed from stainless steel AISI 304, thus guaranteeing complete hygiene and maximum resistance against corrosion. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Maximum flow rate 160 l/min (9.6 m³/h) •• Maximum head 23 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 4 bar •• Continuous service S1

OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 REGULATION (EU) N. 547/2012

•• Special mechanical seal •• EN 10088-3 - 1.4401 (AISI 316) stainless steel motor shaft •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

54


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

25

10

50 Hz  n= 2900 1/min  HS= 0 m

20

0

30

10

40

20

US g.p.m.

30

Imp g.p.m. feet 80

70

AL-RED135

20 60

Head H (metres) 4

47

η = 48%

15

50 44.5

40

10 30

20

5

0

25

0

1

50 2

75

3

4

100 5

125

6

7

150 8

l/min

9

10

m³/h

Flow rate Q 4

MODEL

POWER

Single-phase

Three-phase

kW

HP

AL-RED 135m

AL-RED 135

0.75

1

Q

m³/h

0

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

l/min

0

20

40

60

80

100

120

140

160

23

21

20.5

20

18.5

17

15

13

10

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

55


AL-RED POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-14

Ø 14 mm

6

BEARINGS

6203 ZZ / 6203 ZZ

7

CAPACITOR

Capacitance

8

ELECTRIC MOTOR

Materials

(230 V or 240 V)

(110 V)

20 μF 450 VL

60 μF 300 VL

Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

AL-RED 135m: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. AL-RED 135: three-phase 230/400 V - 50 Hz. ➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

1

56

3

6

5

7

4

8

6


DIMENSIONS AND WEIGHT f

n

a

h1

h3

h

DN1

h2

DN2

s w

MODEL

n1

PORTS

DIMENSIONS mm

kg

Single-phase

Three-phase

DN1

DN2

a

f

h

h1

h2

h3

n

n1

w

s

1~

3~

AL-RED 135m

AL-RED 135

1¼”

1”

31

296

206

97

103

200

186

135

73.5

10

9.1

9.0

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

AL-RED 135m

5.0 A

4.8 A

10.0 A

AL-RED 135

3.1 A

1.8 A

1.0 A

3.0 A

1.7 A

1.0 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

Single-phase

Three-phase

n° pumps

H (mm)

1~

3~

n° pumps

AL-RED 135m

AL-RED 135

70

1450

661

654

112

H (mm)

kg 1~

2240 1043

3~ 1032

H

0 80

00

12

57


HF Centrifugal pumps ➠ Medium flow rates

PERFORMANCE RANGE

•• Flow rate up to 600 l/min (36 m³/h) •• Head up to 39 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature up to +40 °C •• Max. working pressure:

– 6 bar for HF 5-50-51 – 10 bar for HF 5M-70 •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 REGULATION (EU) N. 547/2012

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

58

INSTALLATION AND USE Suitable for use in civil and agricultural applications. The high efficiency and continuous duty capabilities makes these pumps ideal for use in activities such as flood and spray irrigation, drawing water from lakes, rivers and wells, or for any number of different industrial applications where the characteristics of high flow rates and mid to low head are required. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for HF 70, HF 5BM, HF 5AM

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

HF70A

HF70B

Head H (metres) 4

HF70C

η = 60%

HF5AM HF51A

HF5BM

HF51B η = 70% η = 63%

HF5A HF5B HF5C

HF50A HF50B

η = 74%

η = 67%

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

3

6

9

12

15

18

21

24

30

36

l/min

0

50

100

150

200

250

300

350

400

500

600

HFm 50B

HF 50B

0.37

0.50

10

10

9.5

8.5

7.5

6

4

HFm 50A

HF 50A

0.55

0.75

12

12

11.5

11

9.6

8

6

HFm 51B

HF 51B

0.60

0.85

18.2

17.2

16

14

11.5

9

5.4

HFm 51A

HF 51A

0.75

1

21.2

20.2

19

17

14.5

11.6

8.4

HFm 70C

HF 70C

1.1

1.5

29

28

26.5

24.5

22

18.5

15

HFm 70B

HF 70B

1.5

2

33

32

30.5

28.5

26

22.5

19

HF 70A

2.2

3

39

38

36.5

34.5

32

28.5

25

HFm 5C

HF 5C

0.60

0.85

12.5

12

11.7

11

10.2

9.2

8

6.5

HFm 5B

HF 5B

0.75

1

13.7

13.2

13

12.5

11.6

10.5

9.2

8

5

HFm 5A

HF 5A

1.1

1.5

14.5

13.8

13.5

13.2

12.6

11.8

10.5

9.2

6.5

HFm 5BM

HF 5BM

1.1

1.5

20.2

19.2

19

18

17

16

14

12

7.5

HFm 5AM

HF 5AM

1.5

2

22.5

22

21.5

21

20

18.5

16.6

14.5

10

H metres

Q = Flow rate H = Total manometric head HS = Suction height

3

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

59


HF POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304 (cast iron for HF 70-5M)

3

IMPELLER

Brass

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

HF 50 HF 5-51 HF 5M-70

AR-12 AR-14 FN-18

Ø 12 mm Ø 14 mm Ø 18 mm

Pump

Model

HF 50 HF 5-51 HF 5M-70

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ 6204 ZZ / 6204 ZZ

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM

10 μF 450 VL 14 μF 450 VL 20 μF 450 VL 20 μF 450 VL 25 μF 450 VL 45 μF 450 VL 16 μF 450 VL 20 μF 450 VL 25 μF 450 VL 25 μF 450 VL 45 μF 450 VL

25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL 60 μF 300 VL 60 μF 300 VL 60 μF 300 VL 60 μF 250 VL 80 μF 250 VL

6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Ceramic Graphite

Graphite Graphite Ceramic

NBR NBR NBR

HFm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. HF: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

6

7

1

3

4

60

5

8

6


DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w

MODEL

PORTS

Single-phase

Three-phase

HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B – HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM

HF 50B HF 50A HF 51B HF 51A HF 70C HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM

s

n1

DN1

DN2

DIMENSIONS mm a

f

h

h1

h2

n

kg n1

w

s

42

265

200

82

118

166

135

-3

45

300

225

92

133

190

160

4

48.5

373

269

114

155

216

171

12

12

43

316

238

97

141

192

-68

10

1

11

10 1½”

2”

1½”

2”

160 51

386

260

110

150

206

1~

3~

8.1 8.7 12.9 13.0 19.0 21.8 – 14.5 14.5 15.3 19.5 22.0

7.6 8.3 11.9 12.0 18.6 20.5 21.9 13.3 13.3 14.9 18.9 20.9

ABSORPTION MODEL

VOLTAGE (single-phase)

VOLTAGE (three-phase)

MODEL

Single-phase

230 V

240 V

110 V

Three-phase

HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM

2.8 A 3.8 A 4.7 A 5.6 A 8.0 A 10.0 A 4.2 A 4.9 A 6.2 A 7.7 A 9.8 A

2.6 A 3.5 A 4.6 A 5.3 A 7.6 A 9.0 A 3.8 A 4.5 A 5.7 A 7.1 A 9.0 A

5.6 A 7.6 A 9.2 A 11.2 A 16.0 A 20.0 A 8.4 A 10.0 A 12.5 A 14.8 A 19.6 A

HF 50B HF 50A HF 51B HF 51A HF 70C HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM

230 V 2.1 A 3.0 A 3.6 A 4.4 A 5.7 A 7.4 A 9.5 A 3.5 A 3.6 A 5.0 A 5.7 A 7.1 A

400 V 1.2 A 1.7 A 2.1 A 2.5 A 3.3 A 4.3 A 5.5 A 2.0 A 2.1 A 2.9 A 3.3 A 4.1 A

690 V 0.7 A 1.0 A 1.2 A 1.5 A 1.9 A 2.5 A 3.2 A 1.15 A 1.2 A 1.7 A 1.9 A 2.4 A

240 V 2.1 A 3.0 A 3.8 A 4.0 A 5.5 A 7.1 A 9.1 A 3.3 A 3.5 A 4.8 A 5.5 A 6.5 A

415 V 720 V 1.2 A 0.7 A 1.75 A 1.0 A 2.2 A 1.3 A 2.3 A 1.3 A 3.2 A 1.8 A 4.1 A 2.4 A 5.3 A 3.1 A 1.9 A 1.1 A 2.0 A 1.2 A 2.8 A 1.6 A 3.2 A 1.8 A 3.7 A 2.1 A

PALLETIZATION MODEL Three-phase HF 50B HF 50A HF 51B HF 51A HF 70C HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM

n° pumps 75 75 70 70 36 36 36 60 60 60 50 50

kg H (mm) 1~ 3~ 1290 630 590 1290 670 640 1430 920 850 1430 930 860 1470 700 690 1470 800 760 1470 – 810 1540 890 820 1540 890 820 1540 940 910 1540 990 960 1540 1120 1060

CONTAINER n° pumps 135 135 112 112 54 54 54 84 84 84 70 70

H (mm) 2210 2210 2200 2200 2130 2130 2130 2100 2100 2100 2100 2100

kg 1~ 3~ 1110 1050 1190 1140 1460 1350 1480 1360 1050 1020 1200 1130 – 1200 1240 1140 1240 1140 1300 1270 1380 1340 1560 1480

H

0 80

Single-phase HFm 50B HFm 50A HFm 51B HFm 51A HFm 70C HFm 70B – HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM

GROUPAGE

00

12

61


HF Centrifugal pumps ➠ High flow rates

PERFORMANCE RANGE

•• Flow rate up to 2200 l/min (132 m³/h) •• Head up to 24.5 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature up to +40 °C •• Max. working pressure:

– 6 bar for HF 4 – 10 bar for HF 6-8-20-30 •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 REGULATION (EU) N. 547/2012

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

62

INSTALLATION AND USE Suitable for use in civil and agricultural applications. The high efficiency and continuous duty capabilities makes these pumps ideal for use in activities such as flood and spray irrigation, drawing water from lakes, rivers and wells, or for any number of different industrial applications where the characteristics of high flow rates and mid to low head are required. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz

n= 2900 1/min

HS= 0 m

HF8A HF30A η = 78%

HF8B

HF6A

HF20A

HF30B

HF8C

η = 70%

Head H (metres) 

η = 77%

HF20B HF6B

η = 77%

HF20C HF6C

HF4

η = 73%

Flow rate Q 

MODEL

POWER

Single-phase Three-phase kW HP HFm 4

HF 4

0.75

HFm 6C HFm 6B –

HF 6C HF 6B HF 6A

1.1 1.5 1.5 2 2.2 3

HFm 8C

2.2

3

HF 8B

3

4

HF 8A

4

5.5

HFm 20C

2.2

3

Q

m³/h

0

l/min

0

200 300 400 500 600 700 800 900 1000 1100 1200 1400 1600 1700 1800 2000 2200

10

9.3

1

12

18 8.7

24 8

30 7

36 6

11.9 11.7 11.3 10.7 10.2 9.2 14.7 14.5

H metres

14

42

48

54

60

4.7

3

8

6.7

5

3

8.2

6.7

66

13.5 12.8

12

11

9.7

18.5 18.1 17.8 17.2 16.8

16

15

13.8 12.2 10.5 8.3

17

17

16.9 16.8 16.5 15.5 14.5 13.5 11.8

21.5

21

20.7

24.5

24

12.5

-

20

19.5 18.8 17.8 16.5

23.5

23

22.5 21.8 20.8 19.5 18.3 16.8

-

12.5

12

11.5 10.5 9.8

15

10

8.1

84

8

108

120

132

6 9

15

13

7.2

6.3

13

12

4.3

2

9

4.8

2

12

7.8

5

2

15

14.5

13

21.5

21

19.5

HF 20B

3

4

16

-

-

15.5 15.4 15.3 15.2

15

14.5

14

HF 20A

4

5.5

19

-

-

18.5 18.4 18.3 18.2

18

17.5

17

HF 30B

5.5 7.5

18

-

-

-

-

18

18

18

18

18

17.5

HF 30A

7.5

23

-

-

-

-

23

23

23

23

23

22.5 22.5 22.5

Q = Flow rate H = Total manometric head HS = Suction height

102

6

10

96

5

13.5 11.2

9

72

16.2 15.2 17

16.5 15.5 22

18

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

63


HF POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Cast iron (stainless steel AISI 304 for HF 4)

3

IMPELLER

Brass for HF 4, HF 6, HF 8, HF 20 Cast iron for HF 30

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

HF 4 HF 6 HF 8-20 HF 30

AR-14 FN-18 FN-20 FN-24

Ø 14 mm Ø 18 mm Ø 20 mm Ø 24 mm

Pump

Model

HF 4 HF 6 HFm 8C-20C HF 8B-20B HFm 8B-20B HF 8A-20A HF 30

6203 ZZ / 6203 ZZ 6304 ZZ / 6204 ZZ

Pump

Capacitance

6

7

8

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Graphite Graphite Graphite

Graphite Ceramic Ceramic Ceramic

NBR NBR NBR NBR

6206 ZZ - C3 / 6205 ZZ 6306 ZZ - C3 / 6206 ZZ - C3 6307 ZZ - C3 / 6206 ZZ - C3

Single-phase

(230 V or 240 V)

(110 V)

HFm 4 HFm 6C HFm 6B HFm 8C HFm 8B HFm 20C HFm 20B

20 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL 70 μF 450 VL 60 μF 450 VL 70 μF 450 VL 60 μF 450 VL

60 μF 300 VL 60 μF 250 VL 80 μF 250 VL – – – –

HFm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding (up to 1.5 kW). HF: three-phase 230/400 V - 50 Hz up to 4 kW, 400/690 V - 50 Hz from 5.5 to 7.5 kW ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

6

7

1

3

4

64

5

8

6


DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w

s

n1

MODEL

PORTS

DIMENSIONS mm

kg

Single-phase

Three-phase

DN1

DN2

a

f

h

h1

h2

n

n1

w

s

1~

3~

HFm 4 HFm 6C HFm 6B – HFm 8C HFm 8B – HFm 20C HFm 20B – – –

HF 4 HF 6C HF 6B HF 6A

2½”

2½”

47

317

240

97

143

198

155

-68

10

3”

3”

68

411

120

192

240

6

12

80

445 465/445 465 450 465/450 465

30

14

14.5 25.5 26.5 – 35.0 40.0 – 35.0 40.0 – – –

13.2 24.2 25.5 26.7 – 35.0 40.0 – 35.0 40.0 60.9 65.2

HF 8B HF 8A –

4”

HF 20B HF 20A HF 30B HF 30A

4”

82

585

312

190 132

370

160

180

210

245

292

212

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

Single-phase

230 V

240 V

110 V

HFm 4

5.9 A

5.3 A

11.8 A

HFm 6C

8.8 A

8.0 A

17.6 A

HFm 6B

10.8 A

9.8 A

21.6 A

HFm 8C

15.0 A

14.5 A

HFm 8B

20.0 A

19.0 A

HFm 20C

14.5 A

14.0 A

HFm 20B

20.0 A

19.0 A

Three-phase HF 4 HF 6C HF 6B HF 6A HF 8B HF 8A HF 20B HF 20A HF 30B HF 30A

VOLTAGE (three-phase) 230 V 400 V 4.3 A 2.5 A 6.2 A 3.6 A 8.0 A 4.6 A 9.0 A 5.2 A 11.8 A 6.8 A 15.8 A 9.1 A 13.0 A 7.5 A 15.2 A 8.8 A 21.3 A 12.3 A 28.6 A 16.5 A

690 V 1.4 A 2.1 A 2.7 A 3.0 A 3.9 A 5.3 A 4.3 A 5.1 A 7.1 A 9.5 A

240 V 415 V 4.0 A 2.3 A 6.0 A 3.5 A 7.4 A 4.3 A 8.3 A 4.8 A 12.1 A 7.0 A 15.2 A 8.8 A 13.4 A 7.7 A 15.3 A 8.8 A 20.4 A 11.8 A 27.5 A 15.9 A

720 V 1.3 A 2.0 A 2.5 A 2.8 A 4.0 A 5.1 A 4.4 A 5.1 A 6.8 A 9.2 A

PALLETIZATION MODEL Three-phase HF 4 HF 6C HF 6B HF 6A HF 8B HF 8A HF 20B HF 20A HF 30B HF 30A

n° pumps 60 36 36 36 18 18 18 18 12 12

H (mm) 1540 1480 1480 1480 1430 1430 1430 1430 1570 1570

CONTAINER kg

1~ 890 940 970 – – – – – – –

3~ 830 890 940 980 650 740 650 740 750 800

n° pumps 84 54 54 54 24 24 24 24 16 16

kg H (mm) 1~ 3~ 2100 1240 1150 2150 1400 1330 2150 1450 1400 2150 – 1460 1860 – 860 1860 – 980 1860 – 860 1860 – 980 2040 – 990 2040 – 1060

H

0 80

Single-phase HFm 4 HFm 6C HFm 6B – HFm 8C HFm 8B HFm 20C HFm 20B – –

GROUPAGE

00

12

65


NGA Centrifugal pumps with open impeller

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with liquids that are not chemically aggressive towards the materials from which the pump is made. The open impeller design allows liquids containing relatively high levels of impurities to be pumped without the risk of the impeller clogging. As a result of these characteristics the NGA series pumps are used specifically in industry and for transferring water from canals, rivers, reservoirs, tanks, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 350 l/min (21 m³/h) •• Head up to 20 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C

(up to +40 for the version with the technopolymer impeller)

•• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 6 bar •• Passage of suspended solids up to Ø 10 mm •• Continuous service S1

OPTIONALS AVAILABLE ON REQUEST

CONSTRUCTION AND SAFETY STANDARDS

•• Pump with technopolymer impeller •• Special mechanical seal •• Other voltages or 60 Hz frequency

EN 60034-1 IEC 60034-1 CEI 2-3

GUARANTEE

REGULATION (EU) N. 547/2012

1 year subject to terms and conditions

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

66


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

NGA1A

Head H (metres) 4

NGA1B

η = 65%

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

NGAm 1B

NGA 1B

0.55

0.75

NGAm 1A

NGA 1A

0.75

1

Q

m³/h

0

3

6

9

12

15

18

19.5

21

l/min

0

50

100

150

200

250

300

325

350

18

17

16

14.5

13

10.5

8

6

20

19.5

18

16.5

15

12.5

10

8

H metres

Q = Flow rate H = Total manometric head HS = Suction height

6

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

67


NGA POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

IMPELLER

Open impeller in stainless steel 316

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-14

Ø 14 mm

6

BEARINGS

6203 ZZ / 6203 ZZ

7

CAPACITOR

Pump

8

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

NGAm 1B NGAm 1A

16 μF 450 VL 20 μF 450 VL

60 μF 300 VL 60 μF 300 VL

NGAm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. NGA: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

7

2

1

3

68

5

4

8

6


DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w

MODEL

PORTS

Single-phase

Three-phase

NGAm 1B

NGA 1B

NGAm 1A

NGA 1A

s

n1

DIMENSIONS mm

kg

DN1

DN2

a

f

h

h1

h2

n

n1

w

s

1½”

1½”

41

297

227

92

135

190

160

50

10

1~

3~

12.7

11.8

12.8

11.9

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

NGAm 1B

5.6 A

5.3 A

NGAm 1A

6.2 A

6.0 A

MODEL 110 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

11.2 A

NGA 1B

3.3 A

12.0 A

NGA 1A

3.7 A

720 V

1.9 A

1.1 A

3.2 A

1.85 A

1.1 A

2.1 A

1.2 A

3.7 A

2.1 A

1.2 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

NGA 1B

70

NGA 1A

70

Single-phase

Three-phase

NGAm 1B NGAm 1A

CONTAINER kg

n° pumps

H (mm)

kg

1~

3~

1~

1415

910

840

112

2180 1440 1340

1415

920

850

112

2180

1450

3~ H

1350

0

80

00

12

69


NGA-PRO Stainless steel pumps with open impeller

PERFORMANCE RANGE

•• Flow rate up to 350 l/min (21 m³/h) •• Head up to 20 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 6 bar •• Passage of suspended solids up to Ø 10 mm •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The open impeller design allows liquids containing relatively high levels of impurities to be pumped without the risk of the impeller clogging. All of the components in contact with the pumped liquid are constructed in stainless steel AISI 316. As a result of these characteristics the NGA-PRO series pumps find specific use in assemblies for washing fruit, vegetables, fish and shellfish, in industrial assemblies for washing metallic objects and glass containers, as well as for the circulation of cooling liquids. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency

REGULATION (EU) N. 547/2012

GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

70

1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

NGA1A-PRO

Head H (metres) 4

NGA1B-PRO

η = 67%

Flow rate Q 4

MODEL

POWER kW

HP

NGAm 1B - PRO NGA 1B - PRO

0.55

0.75

NGAm 1A - PRO NGA 1A - PRO

0.75

1

Single-phase

Three-phase

Q = Flow rate H = Total manometric head HS = Suction height

Q

m³/h

0

3

6

9

12

15

18

19.5

21

l/min

0

50

100

150

200

250

300

325

350

18

17

16

14.5

13

10.5

8

6

20

19.5

18

16.5

15

12.5

10

8

H metres

6

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

71


NGA-PRO POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 316, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 316

3

IMPELLER

Open impeller in stainless steel 316

4

MOTOR SHAFT

Stainless steel AISI 316

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-14S

Ø 14 mm

6

BEARINGS

6203 ZZ / 6203 ZZ

7

CAPACITOR

Pump

8

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

Viton

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

NGAm 1B - PRO NGAm 1A - PRO

16 μF 450 VL 20 μF 450 VL

60 μF 300 VL 60 μF 300 VL

NGAm - PRO: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. NGA - PRO: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

7

2

1

3

72

5

4

8

6


DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w

MODEL Single-phase

PORTS

Three-phase

NGAm 1B - PRO

NGA 1B - PRO

NGAm 1A - PRO

NGA 1A - PRO

s

n1

DIMENSIONS mm

kg

DN1

DN2

a

f

h

h1

h2

n

n1

w

s

1½”

1½”

41

297

227

92

135

190

160

50

10

1~

3~

13.0

11.9

13.1

12.0

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

NGAm 1B - PRO

5.6 A

5.3 A

NGAm 1A - PRO

6.2 A

6.0 A

MODEL 110 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

11.2 A

NGA 1B - PRO

3.3 A

12.0 A

NGA 1A - PRO

3.6 A

720 V

1.9 A

1.1 A

3.2 A

1.85 A

1.1 A

2.1 A

1.2 A

3.5 A

2.0 A

1.2 A

PALLETIZATION MODEL Single-phase

Three-phase

GROUPAGE n° pumps

H (mm)

CONTAINER kg

1~

3~

n° pumps

H (mm)

kg 1~

NGAm 1B - PRO

NGA 1B - PRO

70

1415

930

850

112

2180 1480

NGAm 1A - PRO

NGA 1A - PRO

70

1415

940

860

112

2180

3~ 1350

H

1490 1360

0

80

00

12

73


2CP Twin-impeller pumps

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The high efficiency and adaptability of these pumps to even the most unusual of applications, makes them ideal for use in the domestic, civil and industrial sectors; in particular for the distribution of water in combination with pressure sets, for pressure boosting and in fire-fighting sets. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 450 l/min (27 m³/h) •• Head up to 112 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 10 bar

(6 bar for 2CP25/130N) •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IPX5 class protection for:

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS

GUARANTEE

COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

1 year subject to terms and conditions

74

– 2CP32/200, – 2CP32/210,

– 2CP40/180, – 2CP40/200


50 Hz  n= 2900 1/min  HS= 0 m

Head H (metres) 4

PERFORMANCE RANGE

2CP25/14 2CP25/130N

2CP25/16

2CP32/210 2CP32/200

2CP40/180

2CP40/200

Flow rate Q 4

75


2CP CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

2CP25/14A

30

2CP25/14B

37

H (feet)

35

2CP25/130N 37

7 6 5 4 3 2 1 0

2CP25/14

20

2CP25/130N

15 10 5

NPSH (feet)

Head H (metres) 4

η = 36%

0

2CP25/14A

Absorbed power P2 (kW)

NPSH (metres)

35

P2 (HP)

2CP25/14B

2CP25/130N

Flow rate Q 4

MODEL Single-phase

POWER kW

HP

0.75

1

2CP 25/14B

1.1

1.5

2CP 25/14A

1.5

2

Three-phase

2CPm 25/130N

2CP 25/130N

2CPm 25/14B 2CPm 25/14A

Q = Flow rate H = Total manometric head HS = Suction height

76

Q

m³/h l/min

H metres

0

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

0

20

30

40

50

42

39

37

34

31

60

70

80

90

100

28.5

25.5

22

18

15

54

52

50

47.5

44,5

41

37

67

65

62

60

57

54

50

33

28

22

45

40

32

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

80

5

0

10 5

15

50 Hz  n= 2900 1/min  HS= 0 m

20

10

25

15

30

20

35

25

40

45US g.p.m.

30

35

Imp g.p.m. feet

70

2CP25/16A 35

60

40

2CP25/16B

42

50

η = 44%

2CP25/16C

43

H (feet)

Head H (metres) 4

43

42

40

30

20

10

C

NPSH (feet)

4

A

B

3 2 1 0 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4

A

B

P2 (HP)

Absorbed power P2 (kW)

NPSH (metres)

0 5

C

0

20

0

1

40 2

60

80

3

4

100 5

120

6

140

7

160

8

9

l/min 10

m³/h

Flow rate Q 4

MODEL Single-phase

Three-phase

POWER kW

HP

1.1

1.5

2CPm 25/16C

2CP 25/16C

2CPm 25/16B

2CP 25/16B

1.5

2CP 25/16A

2.2

Q = Flow rate H = Total manometric head HS = Suction height

Q

m³/h

0

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

100 110 120 140 160

0

20

30

40

50

60

70

80

90

47

46

45

44

42

40

38

35

33

2

H metres 58

56

55

54

3

68

67

l/min

65.5 64.5

6.6

30

27

7.2

8.4

9.6

24

53

51

49

47

45

43

40

37

30

63

62

60

58

56

54

51

48

41

32

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

77


2CP CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

2CP32/200B

NPSH (feet)

NPSH (metres)

H (feet)

Head H (metres) 4

2CP32/200C

Absorbed power P2 (kW)

B

P2 (HP)

C

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

2CP 32/200C

3

4

2CP 32/200B

4

5.5

Q

m³/h l/min

H metres

0

3.0

3.6

4.2

4.8

5.4

6.0

6.6

7.5

8.4

9.6

10.8

12.0

15.0

0

40

50

60

70

80

90

100

110

125

140

160

180

200

250

70

66.5

65.5

65

64

63

62

60.5

59

57

55

52

49.5

46.5

36

85

81

80

79

78

77

76

75

74

72

69

66

62

58

49

Q = Flow rate H = Total manometric head HS = Suction height

78

2.4

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

2CP32/210A

NPSH (feet)

NPSH (metres)

H (feet)

Head H (metres) 4

2CP32/210B

Absorbed power P2 (kW)

A

P2 (HP)

B

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

2CP 32/210B

5.5

7.5

2CP 32/210A

7.5

10

Q

m³/h l/min

H metres

0

2.4

3.0

3.6

4.2

4.8

5.4

6.0

6.6

7.5

8.4

9.6

10.8

12.0

15.0

0

40

50

60

70

80

90

100

110

125

140

160

180

200

250

94

94

93.5

93

92

91

90

89

87

85

83

79

75

70

56

112

111

110.8 110.5 110.3

110

109

108

107

105

102

99

94

89

74

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

79


2CP CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

2CP40/180A

Head H (metres) 4

2CP40/180B

Absorbed power P2 (kW)

C

NPSH (feet)

NPSH (metres)

H (feet)

2CP40/180C

A-B

A

P2 (HP)

B C

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

2CP 40/180C

4

5.5

2CP 40/180B

5.5

7.5

2CP 40/180A

7.5

10

Q

m³/h l/min

H metres

0

6.0

6.6

7.5

8.4

9.6

10.8

0

100

110

125

140

160

64

62

61

60

59

58

15.0

18.0

21.0

24.0

180

200

250

300

350

400

56

54.5

49

43

35

76

73

72.5

72

71

70

69

67.5

64

59.5

54

46

88

85

84.5

84

83

82

81

79.5

76

72

67

60

Q = Flow rate H = Total manometric head HS = Suction height

80

12.0

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

110 350

2CP40/200A

100

300

90

H (feet)

Head H (metres) 4

2CP40/200B

80

70

60

25

6

20 15

4

10

2

5

Absorbed power P2 (kW)

0 11

NPSH (feet)

8

0 14

A

10

13

B

9

12 11

8

10

7

P2 (HP)

NPSH (metres)

50

9

6

8

5

7

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

2CP 40/200B

9.2

12.5

2CP 40/200A

11

15

Q

m³/h l/min

H metres

0

6.0

9

10.8

12.0

15.0

18.0

21.0

24.0

27.0

0

100

150

180

200

250

300

350

400

450

97

94

92

90

88

85

80

74

68

61

105

102

100

98

97

93

88

83

76

69

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

81


2CP 25/130N POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

IMPELLERS

Stainless steel AISI 304

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-14

Ø 14 mm

6

BEARINGS

6203 ZZ / 6203 ZZ

7

CAPACITOR

Pump

8

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

2CPm 25/130N

20 μF 450 VL

60 μF 300 VL

2CPm 25/130N: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2CP 25/130N: three-phase 230/400 V - 50 Hz. ➠ Pump fitted with the three-phase motor option offers IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

7

1

3

82

2

5

4

8

6


DIMENSIONS AND WEIGHT

f

n

a

h1

h

DN1

h2

DN2

w

s n1

MODEL

PORTS

DIMENSIONS mm

kg

Single-phase

Three-phase

DN1

DN2

a

f

h

h1

h2

n

n1

w

s

1~

3~

2CPm 25/130N

2CP 25/130N

1¼”

1”

73

330

201

92

109

180

142

1

10

14.5

14.0

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

2CPm 25/130N

6.3 A

6.0 A

12.6 A

2CP 25/130N

4.6 A

2.6 A

1.5 A

4.3 A

2.5 A

1.5 A

PALLETIZATION MODEL Single-phase

Three-phase

2CPm 25/130N 2CP 25/130N

GROUPAGE

CONTAINER kg

kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

1~

3~

60

1320

890

860

84

1790

1240

1200

H

0

80

00

12

83


2CP POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

IMPELLERS

Brass

3

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

4

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

FN-18

2CP 25/14 2CP 25/16 2CP 32/200 2CP 32/210 2CP 40/180 2CP 40/200 5

BEARINGS

Pump

CAPACITOR

ELECTRIC MOTOR

Elastomer

Ø 18 mm

Graphite

Ceramic

NBR

FN-20

Ø 20 mm

Graphite

Ceramic

NBR

FN-24

Ø 24 mm

Graphite

Ceramic

NBR

FN-32 NU

Ø 32 mm

Graphite

Ceramic

NBR

6204 ZZ / 6204 ZZ 6206 ZZ - C3 / 6206 ZZ - C3 6306 ZZ - C3 / 6206 ZZ - C3 6308 ZZ - C3 / 6308 ZZ - C3

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

25 μF 450 VL

60 μF 250 VL

45 μF 450 VL

80 μF 250 VL

2CPm 25/14B 2CPm 25/16C 2CPm 25/14A 2CPm 25/16B 7

Rotational ring

Model

2CP 25/14 2CP 25/16 2CP 32/200 2CP 32/210 2CP 40/180 2CP 40/200 6

Materials Stationary ring

2CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2CP: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 11 kW ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IPX4.

5

6

1

2

84

4

3

7

5


DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w

s n1

MODEL

PORTS DN1

Single-phase

Three-phase

2CPm 25/14B 2CPm 25/14A 2CPm 25/16C 2CPm 25/16B – – – – – –

2CP 25/14B 2CP 25/14A 2CP 25/16C 2CP 25/16B 2CP 25/16A 2CP 32/200C-B 2CP 32/210B-A 2CP 40/180C 2CP 40/180B-A 2CP 40/200B-A

DN2

1¼”

1½” 2”

DIMENSIONS mm

1”

1¼” 1½”

a

82

95

f

h

h1

h2

n

n1

w

s

1~

3~

404

223 261 223

93 110 93

130 151 130

200 225 200

162 185 162

17 26 17

10 11 10

261

110

151

225

185

26

11

304

132

172

266

206

19

334

139

195

292

232

21

355

160

195

298

19.4 24.2 19.4 24.3 – – – – – –

18.8 23.0 18.8 23.2 24.5 38.0/43.0 54.0/61.0 49.0 54.0/60.0 89.0/90.0

464 542 496 542 566

108 110

kg

14

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

Single-phase 2CPm 25/14B 2CPm 25/14A 2CPm 25/16C 2CPm 25/16B

230 V 7.7 A 10.5 A 7.7 A 10.0 A

240 V 7.4 A 10.0 A 7.4 A 9.6 A

Three-phase 2CP 25/14B 2CP 25/14A 2CP 25/16C 2CP 25/16B 2CP 25/16A 2CP 32/200C 2CP 32/200B 2CP 32/210B 2CP 32/210A 2CP 40/180C 2CP 40/180B 2CP 40/180A 2CP 40/200B 2CP 40/200A

110 V 15.5 A 21.0 A 15.5 A 20.0 A

VOLTAGE (three-phase) 230 V 5.4 A 6.9 A 5.4 A 6.9 A 9.2 A 12.8 A 18.2 A 21.7 A 27.7 A 17.0 A 21.3 A 26.7 A – –

400 V 690 V 3.1 A 1.8 A 4.0 A 2.3 A 3.1 A 1.8 A 4.0 A 2.3 A 5.3 A 3.1 A 7.4 A 4.3 A 10.5 A 6.1 A 12.5 A 7.2 A 16.0 A 9.2 A 9.8 A 5.7 A 12.3 A 7.1 A 15.4 A 8.9 A 17.5 A 10.1 A 20.0 A 11.5 A

240 V 5.2 A 6.6 A 5.2 A 6.6 A 8.8 A 12.3 A 17.7 A 19.9 A 26.0 A 16.5 A 20.8 A 26.0 A – –

415 V 720 V 3.0 A 1.7 A 3.8 A 2.2 A 3.0 A 1.7 A 3.8 A 2.2 A 5.1 A 2.9 A 7.1 A 4.1 A 10.2 A 5.9 A 11.5 A 6.7 A 15.0 A 8.7 A 9.5 A 5.5 A 12.0 A 6.9 A 15.0 A 8.7 A 17.5 A 10.1 A 20.0 A 11.5 A

PALLETIZATION MODEL

H (mm) 1415 1590 1415 1590 1590 1420 1420 1420 1420 1420 1420 1420 1200 1200

1~ 994 1234 994 1239 – – – – – – – – – –

3~ 964 1174 964 1184 1249 700 790 670 750 610 670 740 551 557

n° H (mm) pumps 70 1925 70 2170 70 1925 70 2170 70 2170 24 1840 24 1840 16 1840 16 1840 16 1840 16 1840 16 1840 9 1730 9 1730

kg 1~ 1382 1718 1382 1725 – – – – – – – – – –

3~ 1340 1634 1340 1648 1739 930 1050 880 1000 800 880 980 818 827

H

0

Three-phase 2CP 25/14B 2CP 25/14A 2CP 25/16C 2CP 25/16B 2CP 25/16A 2CP 32/200C 2CP 32/200B 2CP 32/210B 2CP 32/210A 2CP 40/180C 2CP 40/180B 2CP 40/180A 2CP 40/200B 2CP 40/200A

CONTAINER kg

80

Single-phase 2CPm 25/14B 2CPm 25/14A 2CPm 25/16C 2CPm 25/16B – – – – – – – – – –

GROUPAGE n° pumps 50 50 50 50 50 18 18 12 12 12 12 12 6 6

00

12

85


2÷4CP Multi-stage centrifugal pumps

PERFORMANCE RANGE

•• Flow rate up to 130 l/min (7.8 m³/h) •• Head up to 52 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

86

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their quietness, these pumps are widely used in domestic applications such as the distribution of water in combination with small and medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 002073635

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

4CP80-C 4CP100-C

Head H (metres) 4

3CP80-C 3CP100-C

2CP80-C

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase

kW

HP

2CPm 80-C

0.37

0.50

3CPm 80-C

3CP 80-C

0.45

0.60

4CPm 80-C

4CP 80-C

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.4

3.0

3.6

4.2

4.8

5.4

l/min

0

5

10

15

20

25

30

40

50

60

70

80

90 100 110 120 130

27

26

25

24 22.5 21

20 16.5

13

9

5

40

38

37

36 34.5 33

31

27 22.5 17

11

40

0.60

0.85

H metres 52

50

49

47 44.5 42

34 28.5 22.5 16

10

0.60

0.85

38

37

36

35 34.5 33.5 33

31

20

4CPm 100-C 4CP 100-C

0.75

1

50

50

49

48

42 39.5 37

Q = Flow rate H = Total manometric head HS = Suction height

47

46

45

26

23

6.6

7.2

7.8

5

3CPm 100-C 3CP 100-C

28

6.0

17

13.5

34 30.5 26.5 22

10

5

17

11

5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

87


2÷4CP POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

IMPELLERS

Noryl

4

DIFFUSERS

Noryl complete with anti-wear ring

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

STA-13

Ø 13 mm

Pump

Model

7

BEARINGS

2CP 80-C 3CP 80-C 4CP 80-C 3CP 100-C 4CP 100-C 8

9

CAPACITOR

Rotational ring

Elastomer

Ceramic

Graphite

NBR

6202 ZZ - C3 / 6201 ZZ 6203 ZZ / 6203 ZZ

Pump

ELECTRIC MOTOR

Materials Stationary ring

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

2CPm 80-C 3CPm 80-C 4CPm 80-C 3CPm 100-C 4CPm 100-C

10 μF 450 VL 12.5 μF 450 VL

25 μF 250 VL 25 μF 250 VL

14 μF 450 VL

25 μF 250 VL

20 μF 450 VL

60 μF 300 VL

2-3-4CPm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2-3-4CP: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4. 7

1

88

4

3

5

2

8

6

9

7


DIMENSIONS AND WEIGHT f

n

a

h1

h

h3

DN1

h2

DN2

s

w n1

MODEL

PORTS

Single-phase

Three-phase

2CPm 80-C

3CPm 80-C

3CP 80-C

4CPm 80-C

4CP 80-C

DN1

1”

DIMENSIONS mm

DN2

1”

a

f

85

303

110

328

3CPm 100-C

3CP 100-C

85

303

4CPm 100-C

4CP 100-C

110

356

h

172

h1

h2

134

h3

38

172

kg n

158

n1

w

116

1.5

s

9

191

1~

3~

9.0

9.8

9.3

11.0

10.4

10.4

9.9

13.7

12.7

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

2CPm 80-C

2.4 A

2.4 A

4.8 A

3CP 80-C

2.5 A

1.4 A

0.8 A

2.4 A

1.4 A

0.8 A

3CPm 80-C

3.4 A

3.3 A

6.8 A

4CPm 80-C

4.3 A

4.2 A

8.6 A

4CP 80-C

3.4 A

2.0 A

1.1 A

3.3 A

1.9 A

1.1 A

3CPm 100-C

4.1 A

4.0 A

8.2 A

3CP 100-C

3.1 A

1.8 A

1.0 A

3.0 A

1.7 A

1.0 A

4CPm 100-C

6.0 A

5.8 A

12.0 A

4CP 100-C

4.5 A

2.6 A

1.5 A

4.3 A

2.5 A

1.4 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

kg

3~

n° pumps

H (mm)

1~

3~

867

140

2150

1228

Single-phase

Three-phase

2CPm 80-C

98

1547

3CPm 80-C

3CP 80-C

98

1547

945

896

140

2150

1340

1270

4CPm 80-C

4CP 80-C

98

1547

1082 1053

140

2150

1536

1494

3CP 100-C

98

1547

994

965

140

2150

1410

1368

4CP 100-C

84

1661

1150

1150

108

2102

1471

1471

0

80

3CPm 100-C 4CPm 100-C

H

00

12

89


2÷4CR Multi-stage centrifugal pumps

PERFORMANCE RANGE

•• Flow rate up to 120 l/min (7.2 m³/h) •• Head up to 50 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their quietness, these pumps are widely used in domestic applications such as the distribution of water in combination with small and medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

OPTIONALS AVAILABLE ON REQUEST

CONSTRUCTION AND SAFETY STANDARDS

•• Special mechanical seal •• Other voltages or 60 Hz frequency

EN 60335-1 IEC 60335-1 CEI 61-150

GUARANTEE

EN 60034-1 IEC 60034-1 CEI 2-3

1 year subject to terms and conditions

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

90


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

Head H (metres) 4

4CR80

3CR80 3CR100

2CR80

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

l/min

0

5

10

15

20

25

30

40

50

60

70

80

90

100 110 120

20

19

17.5

15

11.5

8

5

32.5

31

29

25

20

15.5

10

28

22.5

16

10

28

25.5

23

20

17

13.5

2CRm 80

0.37

0.50

25

24

3CRm 80

3CR 80

0.45

0.60

38

36

4CRm 80

4CR 80

0.60

0.85

3CRm 100

3CR 100

0.60

0.85

H metres

Q = Flow rate H = Total manometric head HS = Suction height

22.5 21.5 35

34

50

48

47

45

36

35.5

35

34

43

40.5 38.5 33.5

33.5 32.5

32

30

6.6

7.2

5 10

5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

91


2÷4CR POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

IMPELLERS

Noryl GFN2V

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

STA-13

Ø 13 mm

6

BEARINGS

6202 ZZ- C3 / 6201 ZZ

7

CAPACITOR

Pump

8

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

2CRm 80 3CRm 80 4CRm 80 3CRm 100

10 μF 450 VL 12.5 μF 450 VL

25 μF 250 VL 25 μF 250 VL

14 μF 450 VL

25 μF 250 VL

2÷4CRm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. 2÷4CR: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

92

3

2

7

5

4

8

6


DIMENSIONS AND WEIGHT

f

n

a

h1

h

DN1

h2

DN2

w

MODEL

PORTS

Single-phase

Three-phase

2CRm 80

3CRm 80 4CRm 80 3CRm 100

3CR 80 4CR 80 3CR 100

DN1

1”

s

n1

DIMENSIONS mm

DN2

1”

a

f

90

339

h

h1

174

h2

122

52

n

160

kg n1

w

120

s

88

9

1~

3~

5.9

6.8 7.3 7.2

6.2 6.8 6.7

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

2CRm 80

2.4 A

2.4 A

4.8 A

3CR 80

2.2 A

1.3 A

0.8 A

2.1 A

1.2 A

0.7 A

3CRm 80

3.2 A

2.9 A

6.5 A

4CRm 80

4.0 A

3.6 A

8.0 A

4CR 80

2.9 A

1.7 A

1.0 A

2.8 A

1.6 A

0.9 A

3CRm 100

4 .0A

3.6 A

8.0 A

3CR 100

2.9 A

1.7 A

1.0 A

2.8 A

1.6 A

0.9 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

1~

98

1440

600

154

2180

930

3CRm 80

3CR 80

98

1440

690

630

154

2180

1070

970

4CRm 80

4CR 80

98

1440

730

680

154

2180

1140

1070

3CRm 100

3CR 100

98

1440

720

680

154

2180

1130

1050

Single-phase

Three-phase

2CRm 80

3~ H

0

80

00

12

93


MK Vertical multi-stage pumps

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The high efficiency and adaptability of these pumps to even the most unusual of applications, makes them ideal for use in the domestic, civil and industrial sectors; in particular for the distribution of water in combination with pressure sets and for pressure boosting. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 180 l/min (10.8 m³/h) •• Head up to 103 m •• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 10 bar •• Continuous service S1

OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

REGULATION (EU) N. 547/2012

•• Suction and delivery ports with threaded flanges in compiance with ISO 228/1 (1” - 1¼” - 1½)

•• Other voltages or 60 Hz frequency GUARANTEE 1 year subject to terms and conditions

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

94


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

110

10

0

100

30 20

η = 48%

MK5/8

US g.p.m.

40 30

η = 55%

40

Imp g.p.m.

feet 350

η = 65%

300

90

MK3/7

MK5/7

80 Head H (metres) 4

20 10

MK3/8

50 Hz  n= 2900 1/min  HS= 0 m

MK8/6

MK5/6

250

MK3/6

70

MK8/5 MK5/5

60

MK3/5

50

MK3/4

200 MK8/4 MK5/4 150

40 100

30 20

50

10

0

20

0

1

40 2

60 3

80 4

100 5

120

6

7

140 8

160 9

180 10

l/min m³/h

11

Flow rate Q 4

MODEL Single-phase MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6

Three-phase MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6

POWER kW 0.75 0.75 1.1 1.1 1.5 1.1 1.5 1.8 2.2 2.2 1.5 1.8 2.2

HP 1 1 1.5 1.5 2 1.5 2 2.5 3 3 2 2.5 3

Q = Flow rate H = Total manometric head HS = Suction height

Q

m³/h

0

0.6

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

10.8

l/min

0

10

20

40

60

80

100

120

140

160

180

25

22

31.5

24.0

15.0

H metres

50

49

47

42.5

35

62

60

58.5

52.5

43.5

30

75

73

70

62.5

51.5

36

88

85

81.5

73

59.5

42

100

98

94

85

70.5

50

53

51

48

45

40

32

67

64

61

57.5

51

41.5

29

80

77

74

70

61

49

34

87

84

80

75

64.5

51.5

37

103

99

93

85

74.5

58.5

40

56.0

54.0

52.0

50.0

46.0

39.0

70.0

67.5

66.0

63.0

58.0

50.0

40.0

30.0

18.0

86.0

82.0

78.0

74.0

68.0

58.0

46.5

35.0

20.0

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

95


MK POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

SUCTION BODY

Cast iron, complete with threaded suction port in compliance with ISO 228/1

2

EXTERNAL SLEEVE

Stainless steel AISI 304

3

DELIVERY BODY

Cast iron, complete with threaded suction port in compliance with ISO 228/1

4

IMPELLERS AND DIFFUSERS

Noryl GFN2V

5

DIAPHRAGMS

Stainless steel AISI 304 complete with anti-wear rings

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

MECHANICAL SEAL

Shaft

Position

Diameter

FN-18 8

Ø 18 mm

Materials Stationary ring

Rotational ring

Elastomer

Graphite

Ceramic

NBR

BEARINGS Model 6304 ZZ / 6204 ZZ

9

CAPACITOR Pump

10

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6

25 μF 450 VL 25 μF 450 VL 25 μF 450 VL 25 μF 450 VL 31.5 μF 450 VL 25 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL 50 μF 450 VL 50 μF 450 VL 31.5 μF 450 VL 45 μF 450 VL 50 μF 450 VL

60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL 60 μF 250 VL – – – 60 μF 250 VL – –

ELECTRIC MOTOR

8

9

10

6 8

7

➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance MKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. MK: three-phase 230/400 V - 50 Hz. – Insulation: F class.   – Protection: IP X4.

96

3

2 5 4

1


DIMENSIONS AND WEIGHT

ABSORPTION MODEL

h2

h

DN2

a

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6

5.0 A 6.0 A 6.5 A 7.0 A 9.0 A 6.5 A 8.5 A 9.5 A 10.5 A 11.5 A 8.5 A 9.5 A 11.5 A

4.8 A 5.8 A 6.3 A 6.8 A 8.7 A 6.3 A 8.2 A 9.1 A 10.2 A 11.0 A 8.2 A 9.1 A 11.0 A

10.0 A 12.0 A 13.0 A 14.0 A 18.0 A 13.0 A 17.0 A 19.0 A 21.0 A 23.0 A 17.0 A 19.0 A 23.0 A

h1

DN1

MODEL

s

w2

b

n3

n2

c

w1 n1

MODEL Single-phase MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6

Three-phase MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6

PORTS DN1

1¼”

DN2

1”

N° STAGES 4 5 6 7 8 4 5 6 7 8 4 5 6

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6

3.5 A 4.2 A 4.8 A 5.2 A 5.5 A 4.8 A 5.2 A 6.1 A 7.8 A 8.7 A 5.2 A 6.1 A 8.7 A

2.0 A 2.4 A 2.8 A 3.0 A 3.2 A 2.8 A 3.0 A 3.5 A 4.5 A 5.0 A 3.0 A 3.5 A 5.0 A

1.2 A 1.4 A 1.6 A 1.7 A 1.8 A 1.6 A 1.7 A 2.0 A 2.6 A 2.9 A 1.7 A 2.0 A 2.9 A

3.4 A 4.0 A 4.6 A 5.0 A 5.3 A 4.6 A 5.0 A 5.8 A 7.5 A 8.3 A 5.0 A 5.8 A 8.3 A

2.0 A 2.3 A 2.7 A 2.9 A 3.1 A 2.7 A 2.9 A 3.4 A 4.3 A 4.8 A 2.9 A 3.4 A 4.8 A

1.2 A 1.3 A 1.6 A 1.7 A 1.8 A 1.6 A 1.7 A 2.0 A 2.5 A 2.8 A 1.7 A 2.0 A 2.8 A

DIMENSIONS mm a

s

91

94.5

h 469 493 517 541 565 469 493 517 541 565 469 493 517

h1

41.5

h2 152 176 200 224 248 152 176 200 224 248 152 176 200

kg

w1

w2

n1

n2

n3

b

c

143

146

194

130

225

9.5

14.5

1~ 22.3 23.1 23.9 24.7 26.6 22.3 24.3 25.8 27.3 28.0 23.6 25.1 26.6

3~ 21.6 22.4 23.2 24.0 25.6 21.6 23.4 25.0 26.6 27.3 22.7 24.3 25.9

PALLETIZATION MODEL Three-phase MK 3/4 MK 3/5 MK 3/6 MK 3/7 MK 3/8 MK 5/4 MK 5/5 MK 5/6 MK 5/7 MK 5/8 MK 8/4 MK 8/5 MK 8/6

n° pumps 35 35 35 35 35 35 35 35 35 35 35 35 35

H (mm) 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440 1440

kg 1~ 798 826 854 882 948 798 868 920 973 997 843 896 948

3~ 773 801 829 857 913 773 836 892 948 973 812 868 924

H

0 80

Single-phase MKm 3/4 MKm 3/5 MKm 3/6 MKm 3/7 MKm 3/8 MKm 5/4 MKm 5/5 MKm 5/6 MKm 5/7 MKm 5/8 MKm 8/4 MKm 8/5 MKm 8/6

GROUPAGE / CONTAINER

00

12

97


CK Self-priming liquid ring pumps

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with diesel, clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a specific result of the pump’s operating principle they are suitable for use in all situations where a compact self-priming pump is required or where the fluid supply is limited, irregular or contains air. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 51 m

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +90 °C •• Temperature of diesel up to +55°C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

PATENTS - TRADE MARKS - MODELS

CONSTRUCTION AND SAFETY STANDARDS

•• Motor bracket: patent n° IT1243605 •• CK 80-E/90-E Registered Community Design n° 342159-0008

EN 60335-1 IEC 60335-1 CEI 61-150

OPTIONALS AVAILABLE ON REQUEST

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

98

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IP X5 class protection for CK 80-E, CK 90-E

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

CK90-E

Head H (metres) 4

CK80-E

CK50

CK50-BP

Flow rate Q 4 MODEL

POWER kW

HP

CK 50

0.37

0.50

CKm 50-BP

CK 50-BP

0.25

0.33

CKm 80-E

CK 80-E

0.55

0.75

CKm 90-E

CK 90-E

0.75

1

Single-phase Three-phase CKm 50

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

3.0

0

5

10

15

20

25

30

35

40

50

35

31

27

24

20

16

13

9

5

20

20

20

20

20

16.5

13

9

5

48

46

42

38

34

30

26

22

18

10

51

49

45

41

37

33

29

25

21

13

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

CK 50-BP = pump with integral by-pass

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

99


CK POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

MOTOR BRACKET

Aluminium with brass insert (patented), reduces the risk of impeller seizure

3

IMPELLER

Brass, star type with open radial vanes

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-12V

Ø 12 mm

Pump

Model

6

BEARINGS

CK 50 CK 50-BP CK 80-E CK 90-E 7

CAPACITOR

ELECTRIC MOTOR

Rotational ring

Elastomer

Ceramic

Graphite

Viton

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

12.5 μF 450 VL

25 μF 250 VL

16 μF 450 VL 20 μF 450 VL

60 μF 300 VL 60 μF 300 VL

CKm 50 CKm 50-BP CKm 80-E CKm 90-E 8

Materials Stationary ring

CKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CK: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

100

3

2

7

5

4

6

8


DIMENSIONS AND WEIGHT

i

f

h1

h3

h

h2

DN1

DN2

n1

s a

w

MODEL

m

n

PORTS

Single-phase

Three-phase

CKm 50

CK 50

CKm 50-BP

CK 50-BP

CKm 80-E

CK 80-E

CKm 90-E

CK 90-E

DIMENSIONS mm

DN1

DN2

¾”

¾”

1”

1”

a

f

41

250

45

254

50

296

kg

h

h1

h2

h3

i

m

n

n1

w

152

128

23

151

75

80

120

100

69

s

7 180

136

31

167

81

90

140

112

77

1~

3~

7.4

6.8

10.8

9.9

10.9

10.0

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

CKm 50

3.0 A

2.9 A

6.2 A

CK 50

2.1 A

1.2 A

0.7 A

2.0 A

1.2 A

0.7 A

CKm 50-BP

3.0 A

2.9 A

6.2 A

CK 50-BP

2.1 A

1.2 A

0.7 A

2.0 A

1.2 A

0.7 A

CKm 80-E

5.0 A

4.8 A

9.8 A

CK 80-E

3.5 A

2.0 A

1.2 A

3.4 A

2.0 A

1.2 A

CKm 90-E

4.8 A

4.4 A

9.4 A

CK 90-E

3.5 A

2.0 A

1.2 A

3.4 A

2.0 A

1.2 A

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

PALLETIZATION MODEL Single-phase

Three-phase

CKm 50

CK 50

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

120

1280

910

kg

3~

n° pumps

H (mm)

1~

3~

840

180

1850

1350

1240

CKm 50-BP

CK 50-BP

120

1280

910

840

180

1850

1350

1240

CKm 80-E

CK 80-E

102

1370

1120

1030

136

1780

1490

1370

CKm 90-E

CK 90-E

102

1370

1130

1040

136

1780

1500 1380

H

0

80

00

12

101


CKR Self-priming liquid ring pumps ➠ with double anti-seize inserts

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use with clean water or liquids that do not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a specific result of the pump’s operating principle they are suitable for use in all situations where a compact self-priming pump is required or where the fluid supply is limited, irregular or contains air. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 51 m •• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +90 °C •• Temperature of diesel up to +55°C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

PATENTS - TRADE MARKS - MODELS

CONSTRUCTION AND SAFETY STANDARDS

•• Motor bracket: patent n° IT1243605 •• Registered Community Design n° 342159-0008

EN 60335-1 IEC 60335-1 CEI 61-150

OPTIONALS AVAILABLE ON REQUEST

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

102

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IPX5 class protection

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

CKR90-E

Head H (metres) 4

CKR80-E

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase

kW

HP

CKRm 80-E

CKR 80-E

0.55

0.75

CKRm 90-E

CKR 90-E

0.75

1

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

3.0

l/min

0

5

10

15

20

25

30

35

40

50

48

46

42

38

34

30

26

22

18

10

51

49

45

41

37

33

29

25

21

13

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

103


CKR POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with stainless steel insert to prevent impeller seizure due to the formation of rust . The pump body is complete with threaded ports in compliance with ISO 228/1

2

MOTOR BRACKET

Aluminium with brass insert (patented), reduces the risk of impeller seizure

3

IMPELLER

Brass, star type with open radial vanes

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-12V

Ø 12 mm

6

BEARINGS

6203 ZZ / 6203 ZZ

7

CAPACITOR

Pump

8

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

Viton

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

CKRm 80-E CKRm 90-E

16 μF 450 VL 20 μF 450 VL

60 μF 300 VL 60 μF 300 VL

CKRm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. CKR: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

6

1

104

3

2

6

7

5

4

8


DIMENSIONS AND WEIGHT

i

f

h1

h3

h

h2

DN1

DN2

n1

s a

w

MODEL

m

n

PORTS

Single-phase

Three-phase

CKRm 80-E

CKR 80-E

CKRm 90-E

CKR 90-E

DN1 1”

DIMENSIONS mm

DN2 1”

a 50

f

h

296

180

h1

h2

136

h3

31

i

167

81

kg m

n

90

140

n1 112

w 77

s 7

1~

3~

10.8

9.9

10.9

10.0

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

MODEL

VOLTAGE (three-phase)

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

CKRm 80-E

5.0 A

4.8 A

9.8 A

CKR 80-E

3.5 A

2.0 A

1.2 A

3.4 A

2.0 A

1.2 A

CKRm 90-E

4.8 A

4.4 A

9.4 A

CKR 90-E

3.5 A

2.0 A

1.2 A

3.4 A

2.0 A

1.2 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

CKR 80-E

102

1370

CKR 90-E

102

1370

Single-phase

Three-phase

CKRm 80-E CKRm 90-E

CONTAINER kg 3~

n° pumps

H (mm)

1120

1030

136

1130

1040

136

1~

kg 1~

3~

1780

1490

1370

1780

1500 1380

H

0 80

00

12

105


JSW1 Self-priming “JET” pumps

PERFORMANCE RANGE

•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 47 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• Registered Italian model nº 72753 •• European Patent n° 1 510 696

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with technopolymer impeller •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

106


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

JSW1A

JSW1B

Head H (metres) 4

JSW1C

4

4 4

Flow rate Q 4

MODEL Single-phase Three-phase JSWm 1C – JSWm 1B JSW 1B JSWm 1A JSW 1A

POWER kW 0.37 0.50 0.60

HP 0.50 0.70 0.85

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

3.0

l/min

0

5

10

15

20

25

30

35

40

45

50

35

32

27

24

21

19

17

16

15

14

13

41

36

31

27

24

22

20

19

17

16

15

47

42

38

34

31

28.5

26

24

22

21.5

19

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

107


JSW1 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

NOZZLE ASSEMBLY

Noryl GFN2V

4

IMPELLER

Brass

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-12

Ø 12 mm

7

BEARINGS

6201 ZZ / 6201 ZZ

8

CAPACITOR

Pump

9

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

JSWm 1C JSWm 1B JSWm 1A

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL

25 μF 250 VL 25 μF 250 VL 25 μF 250 VL

JSWm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JSW: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

1

108

3

4

7

6

8

5

9

7


DIMENSIONS AND WEIGHT f

n

a

h1

h

h3

DN1

h2

DN2

w

MODEL

PORTS

Single-phase

Three-phase

JSWm 1C

JSWm 1B

JSW 1B

JSWm 1A

JSW 1A

DN1 1”

s

n1

DIMENSIONS mm

DN2 1”

a

f

115

373

h 171

h1 127

h2 33.5

h3 160.5

kg n 160

n1

w

124

24

s 10

1~

3~

9.2

10.0

9.5

10.3

10.1

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

MODEL

VOLTAGE (three-phase)

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

JSW 1B

2.1 A

1.2 A

0.7 A

2.0 A

1.2 A

0.7 A

JSW 1A

2.8 A

1.6 A

0.9 A

2.7 A

1.6 A

0.9 A

JSWm 1C

2.4 A

2.2 A

4.8 A

JSWm 1B

3.2 A

2.9 A

6.5 A

JSWm 1A

3.6 A

3.3 A

7.3 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~ 926

kg

3~

n° pumps

H (mm)

1~

140

2060

1312

Single-phase

Three-phase

JSWm 1C

98

1484

3~

JSWm 1B

JSW 1B

98

1484 1004

955

140

2060 1424

JSWm 1A

JSW 1A

98

1484 1033

1014

140

2060 1466 1438

H

1354

0 80

00

12

109


JSW2 Self-priming “JET” pumps

PERFORMANCE RANGE

•• Flow rate up to 80 l/min (4.8 m³/h) •• Head up to 70 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6.5 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• Registered Italian model nº 72753 •• European Patent n° 1 510 696

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with technopolymer impeller •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

110


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

JSW15H

JSW12H

Head H (metres) 4

JSW10H JSW15M JSW12M

JSW10M

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase JSWm 10H JSW 10H JSWm 12H JSW 12H JSWm 15H JSW 15H JSWm 10M JSW 10M JSWm 12M JSW 12M JSWm 15M JSW 15M

kW 0.75 0.90 1.1 0.75 0.90 1.1

HP 1 1.25 1.5 1 1.25 1.5

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.4

2.7

3.0

3.6

4.2

4.8

l/min

0

5

10

15

20

25

30

40

45

50

60

70

80

56

51

47

44

41

39

36

32

30

28

64

58

54

51

48

45

43

38

36

34

70

66

62

58

54

51

48

43

41

38

46

42

40

38

37

35

33

30

29

27

25

23

21

50

48

46

44

42

41

39

36

35

33

31

29

27

55

52

50

48

46

45

43

40

39

37

35

33

30

H metres

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

111


JSW2 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

NOZZLE ASSEMBLY

Noryl GFN2V

4

IMPELLER

Brass

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

AR-14

Ø 14 mm

7

BEARINGS

6203 ZZ / 6203 ZZ

8

CAPACITOR

Pump

9

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

JSWm 10H-M JSWm 12H-M JSWm 15H-M

20 μF 450 VL 25 μF 450 VL 25 μF 450 VL

60 μF 300 VL 60 μF 300 VL 60 μF 300 VL

JSWm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JSW: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

1

112

3

7

4

6

8

5

9

7


DIMENSIONS AND WEIGHT

f

n

a

h1

h

h3

DN1

h2

DN2

w

MODEL

PORTS DN1

s

n1

DIMENSIONS mm

Single-phase

Three-phase

1~

3~

JSWm 10H

JSW 10H

13.7

13.8

JSWm 12H

JSW 12H

14.7

13.6

JSWm 15H

JSW 15H

15.1

14.8

JSWm 10M

JSW 10M

13.7

13.8

JSWm 12M

JSW 12M

14.7

13.6

JSWm 15M

JSW 15M

15.1

14.8

1”

DN2

1”

a

f

113.5

h

402

201

h1

h2

147

h3

kg

35

182

n

180

n1

w

142

22

s

10

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

JSWm 10H

4.7 A

4.5 A

9.4 A

JSW 10H

3.5 A

2.0 A

1.2 A

3.4 A

2.0 A

1.2 A

JSWm 12H

5.4 A

5.0 A

10.8 A

JSW 12H

4.2 A

2.4 A

1.4 A

4.0 A

2.3 A

1.3 A

JSWm 15H

6.6 A

6.0 A

13.2 A

JSW 15H

5.5 A

3.2 A

1.8 A

5.3 A

3.1 A

1.8 A

JSWm 10M

5.0 A

4.6 A

10.0 A

JSW 10M

3.6 A

2.1 A

1.2 A

3.5 A

2.0 A

1.2 A

JSWm 12M

5.7 A

5.2 A

11.4 A

JSW 12M

4.5 A

2.6 A

1.5 A

4.3 A

2.5 A

1.4 A

JSWm 15M

6.6 A

6.0 A

13.2 A

JSW 15M

5.5 A

3.2 A

1.8 A

5.3 A

3.1 A

1.8 A

PALLETIZATION MODEL

GROUPAGE n° pumps

Single-phase

Three-phase

JSWm 10H

JSW 10H

72

H (mm)

CONTAINER kg

1~

1460 1000

H (mm)

kg

3~

n° pumps

1010

96

1900 1330

1~

3~ 1340

JSWm 12H

JSW 12H

72

1460 1080 1000

96

1900 1430

1330

JSWm 15H

JSW 15H

72

1460

96

1900

1470

1440

1110

1090

JSW 10M

72

1460 1000

1010

96

1900 1330

1340

JSW 12M

72

1460 1080 1000

96

1900 1430

1330

JSWm 15M

JSW 15M

72

1460

96

1900

1440

1110

1090

1470

0 80

JSWm 10M JSWm 12M

H

00

12

113


JSW3 Self-priming “JET” pumps

PERFORMANCE RANGE

•• Flow rate up to 160 l/min (9.6 m³/h) •• Head up to 96 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature between -10 °C and +40 °C •• Max. working pressure 10 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JSW pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic, civil and industrial applications such as the distribution of water in combination with pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• Registered Italian model nº 72753

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• IPX5 class protection

GUARANTEE 1 year subject to terms and conditions

114


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

JSW3AH

Head H (metres) 4

JSW3BH

JSW3CH

JSW3AM

JSW3AL

JSW3BM

JSW3CM

JSW3BL JSW3CL

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase JSWm 3CH JSW 3CH JSWm 3BH JSW 3BH – JSW 3AH JSWm 3CM JSW 3CM JSWm 3BM JSW 3BM – JSW 3AM JSWm 3CL JSW 3CL JSWm 3BL JSW 3BL – JSW 3AL

kW 1.1 1.5 2.2 1.1 1.5 2.2 1.1 1.5 2.2

HP 1.5 2 3 1.5 2 3 1.5 2 3

m³/h

0

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

3.0

3.6

4.2

4.8

l/min

0

10

15

20

25

30

35

40

45

50

60

70

80 100 120 140 160

64 76 96 52 H metres 60 74 42 51 62

60 70 90 50 58 70 40 48 60

55 67 86 48 56 68 39 46 58

51 64 82 45 54 67 38 45 57

48 61 79 44 52 65 37 44 56

45 42.5 40 58 55.5 53 75 71.5 69 42 40 38 51 49 47 63 61 59 36 35 34 43 42 41 55 54 53

39 51 66 37 46 58 33 40 52

37 49 64 35 45 56 32 39 51

34 45 58 32 42 54 30 37 49

31 41 54 29 39 51 28 35 47

39 50 27 37 49 26 33 45

Q

Q = Flow rate H = Total manometric head HS = Suction height

6.0

23 33 44 23 30 42

7.2

8.4

9.6

20 30 40 20 17 15 27 24 22 39 36.5 35

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

115


JSW3 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Cast iron

3

NOZZLE ASSEMBLY

Noryl GFN2V

4

IMPELLER

Brass

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

FN-18

Ø 18 mm

7

BEARINGS

6204 ZZ / 6204 ZZ

8

CAPACITOR

Pump

9

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Graphite

Ceramic

NBR

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

JSWm 3C JSWm 3B

31.5 μF 450 VL 45 μF 450 VL

60 μF 250 VL 80 μF 250 VL

JSWm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JSW: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

7

2

1

116

3

4

6

8

5

9

7


DIMENSIONS AND WEIGHT f

n

a

h

h2 h1

h3

DN1

DN2

w

MODEL

PORTS

Single-phase

Three-phase

JSWm 3CH JSWm 3BH – JSWm 3CM JSWm 3BM – JSWm 3CL JSWm 3BL –

JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL

DN1

1¼”

s

n1

DIMENSIONS mm

DN2

1”

a

f

155

h

530

242

h1

h2

165

43

h3

208

kg n

206

n1

w

164

30

s

1~

3~

11

24.9 26.1 – 24.9 26.1 – 24.9 26.1 –

22.9 25.1 26.4 22.9 25.1 26.4 22.9 25.1 26.4

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

JSWm 3CH JSWm 3BH JSWm 3CM JSWm 3BM JSWm 3CL JSWm 3BL

8.0 A 9.0 A 7.9 A 9.3 A 7.5 A 9.7 A

7.3 A 8.2 A 7.2 A 8.5 A 6.9 A 9.0 A

16.0 A 18.0 A 15.8 A 18.6 A 15.0 A 19.4 A

JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL

5.5 A 6.9 A 9.0 A 5.9 A 7.3 A 9.5 A 5.5 A 7.3 A 9.0 A

3.2 A 4.0 A 5.2 A 3.4 A 4.2 A 5.5 A 3.2 A 4.2 A 5.2 A

1.8 A 2.3 A 3.0 A 2.0 A 2.4 A 3.2 A 1.8 A 2.4 A 3.0 A

5.3 A 6.6 A 8.6 A 5.7 A 7.0 A 9.1 A 5.3 A 7.0 A 8.6 A

3.1 A 3.8 A 5.0 A 3.3 A 4.0 A 5.3 A 3.1 A 4.0 A 5.0 A

1.8 A 2.2 A 2.9 A 1.9 A 2.3 A 3.1 A 1.8 A 2.3 A 2.9 A

PALLETIZATION MODEL Three-phase JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL

H (mm)

35 35 35 35 35 35 35 35 35

1420 1420 1420 1420 1420 1420 1420 1420 1420

CONTAINER kg

1~ 890 930 – 890 930 – 890 930 –

3~ 820 900 941 820 900 941 820 900 941

n° pumps

H (mm)

49 49 49 49 49 49 49 49 49

1930 1930 1930 1930 1930 1930 1930 1930 1930

kg 1~ 3~ 1240 1140 1300 1250 – 1310 1240 1140 1300 1250 – 1310 1240 1140 1300 1250 – 1310

H

0 80

Single-phase JSWm 3CH JSWm 3BH – JSWm 3CM JSWm 3BM – JSWm 3CL JSWm 3BL –

GROUPAGE n° pumps

00

12

117


JCR Self-priming “JET” pumps

PERFORMANCE RANGE

•• Flow rate up to 80 l/min (4.8 m³/h) •• Head up to 72 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6.5 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

118

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JCR pumps are designed to pump water even in cases where air is present. As a result of their reliability and the fact that they are easy to use, they are recommended for use in domestic applications such as the distribution of water in combination with small or medium sized pressure sets, and for the irrigation of gardens and allotments, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• European Patent n° 1 510 696

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

JCR15H

Head H (metres) 4

JCR10H JCR15M JCR1A

JCR1B

JCR10M

JCR1C

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase JCRm 1C – JCRm 1B JCR 1B JCRm 1A JCR 1A JCRm 10H JCR 10H JCRm 15H JCR 15H JCRm 10M JCR 10M JCRm 15M JCR 15M

kW 0.37 0.50 0.60 0.75 1.1 0.75 1.1

HP 0.50 0.70 0.85 1 1.5 1 1.5

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

3.0

3.6

4.2

4.8

60

70

80

0

5

10

15

20

25

30

35

40

50

35

32

27

24

21

19

17

16

15

13

41

36

31

27

24

22

20

19

17

15

47

42

38

34

31

28.5

26

24

22

19

56

50

45

41

37

33

30

27

25

22

72

67

61

56

51

47

43

40

37

32

46

44

41

39

37

35

32

30

28

25

22

21

19

55

53

50

48

46

43

41

39

37

34

31

29

27

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

119


JCR POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

NOZZLE ASSEMBLY

Noryl GFN2V

4

IMPELLER

Noryl GFN2V

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

JCR 1C-B-A JCR 10-15

AR-12 AR-14

Ø 12 mm Ø 14 mm

Pump

Model

JCR 1C-B-A JCR 10H-M / 15H-M

6201 ZZ / 6201 ZZ 6203 ZZ / 6203 ZZ

Pump

Capacitance

7

8

9

BEARINGS

CAPACITOR

ELECTRIC MOTOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Ceramic

Graphite Graphite

NBR NBR

Single-phase

(230 V or 240 V)

(110 V)

JCRm 1C JCRm 1B JCRm 1A JCRm 10H-M JCRm 15H-M

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL 20 μF 450 VL 25 μF 450 VL

25 μF 250 VL 25 μF 250 VL 25 μF 250 VL 60 μF 300 VL 60 μF 300 VL

JCRm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. JCR: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

1

120

3

7

4

6

8

5

7

9


DIMENSIONS AND WEIGHT

f

n

a

h1

h

h2

DN1

DN2

w

MODEL

PORTS

Single-phase

Three-phase

JCRm 1C

JCRm 1B

JCR 1B

JCRm 1A JCRm 10H-M JCRm 15H-M

JCR 15H-M

DN1

s

n1

DIMENSIONS mm

DN2

1~

3~

5.6

6.4

6.3

JCR 1A

6.9

6.4

JCR 10H-M

9.4

9.3

10.5

10.3

1”

1¼”

1”

1”

a

f

90

h

339

117

h1

174

406

206

h2

122

52

145

55

n

kg

160

184

n1

w

120

s

88

135

9

110

10

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

Single-phase

230 V

240 V

110 V

JCRm 1C

2.4 A

2.2 A

4.8 A

JCRm 1B

3.2 A

2.9 A

6.5 A

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

JCR 1B

2.1 A

JCR 1A

2.8 A

JCR 10H

720 V

1.2 A

0.7 A

2.0 A

1.2 A

0.7 A

1.6 A

0.9 A

2.7 A

1.6 A

0.9 A

3.5 A

2.0 A

1.2 A

3.4 A

2.0 A

1.2 A

JCR 15H

5.5 A

3.2 A

1.8 A

5.3 A

3.1 A

1.8 A

JCRm 1A

3.6 A

3.3 A

7.3 A

JCRm 10H

4.7 A

4.5 A

9.4 A

JCRm 15H

6.6 A

6.0 A

13.2 A

JCRm 10M

5.0 A

4.6 A

10.0 A

JCR 10M

3.6 A

2.1 A

1.2 A

3.5 A

2.0 A

1.2 A

JCRm 15M

6.6 A

6.0 A

13.2 A

JCR 15M

5.5 A

3.2 A

1.8 A

5.3 A

3.1 A

1.8 A

PALLETIZATION MODEL

GROUPAGE H (mm)

98

1440

JCR 1B

98

1440

JCRm 1A

JCR 1A

98

1440

JCRm 10H-M

JCR 10H-M

72

1460

JCRm 15H-M

JCR 15H-M

72

1460

Three-phase

JCRm 1C JCRm 1B

kg

kg

3~

n° pumps

H (mm)

570

154

2180

880

650

640

154

2180

1010

990

700

650

154

2180 1080

1010

700

690

96

1900

920

910

780

760

96

1900 1030

1010

1~

1~

3~ H

0 80

n° pumps

Single-phase

CONTAINER

00

12

121


PLURIJET 80-100 Self-priming multi-stage pumps

PERFORMANCE RANGE

•• Flow rate up to 130 l/min (7.8 m³/h) •• Head up to 50 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Suitable for use with clean water even where air is present and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming “PLURIJET” pumps are designed to pump water even in cases where air is present. As a result of their quietness, reliability and low energy consumption they are recommended for use in domestic and civil applications such as the pressurisation and distribution of water in combination with pressure sets, and in rain water recovery and irrigation systems, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• PLURIJET® is a registered trade mark n° 3974301 •• Registered Community Design n° 342159-0006

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

122


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

PLURIJET 4/80

Head H (metres) 4

4/100 3/80 3/100

Flow rate Q 4 MODEL Single-phase

POWER Three-phase

kW

HP 0.60

PLURIJETm 3/80

0.45

PLURIJETm 4/80

PLURIJET 4/80

0.60

0.85

PLURIJETm 3/100

PLURIJET 3/100

0.60

0.85

PLURIJETm 4/100

PLURIJET 4/100

0.75

1

Q = Flow rate H = Total manometric head HS = Suction height

Q

m³/h l/min

H metres

0

0.3

0.6

1.2

1.8

2.4

3.0

3.6

4.2

4.8

6.0

7.2

70

80

100 120 130

0

5

10

20

30

40

50

60

38

36

35

32.5

29

25

20

15.5 10.5

5

50

48

47

43

28

22.5

16

10

36

35.5

35

33.5

32

30

28

26

23

20

13.5

5

46

45

44

42

40

38

35.5

33

30

26.5

19

10

38.5 32.5

7.8

5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

123


PLURIJET 80-100 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Stainless steel AISI 304

3

IMPELLERS

Noryl GFN2V

4

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

5

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

STA-13

Ø 13 mm

6

BEARINGS

Materials

Pump

8

CAPACITOR

Elastomer

Ceramic

Graphite

NBR

6202 ZZ - C3 / 6201 ZZ 6203 ZZ / 6203 ZZ

Pump

ELECTRIC MOTOR

Rotational ring

Model

PLURIJET 3/80 PLURIJET 3/100 PLURIJET 4/80 PLURIJET 4/100 7

Stationary ring

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

PLURIJETm 3/80 PLURIJETm 4/80 PLURIJETm 3/100 PLURIJETm 4/100

12.5 μF 450 VL

25 μF 250 VL

14 μF 450 VL

25 μF 250 VL

20 μF 450 VL

60 μF 300 VL

PLURIJETm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PLURIJET: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

2

1

124

3

6

5

6

7

4

8


DIMENSIONS AND WEIGHT f

n

a

h1

h

DN1

h2

DN2

w

s n1

MODEL Single-phase

PORTS DN1

Three-phase

PLURIJETm 3/80

PLURIJETm 4/80

PLURIJET 4/80

PLURIJETm 3/100

PLURIJET 3/100

PLURIJETm 4/100

PLURIJET 4/100

1”

DIMENSIONS mm

DN2

1”

a

f

110

328

135

351

110

328

135

378

h

h1

172

h2 38

134

191

n

158

kg n1

116

w

2

s

9

61

1~

3~

10.0

11.3

10.7

10.5

10.0

13.7

12.7

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

VOLTAGE (three-phase)

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

PLURIJET 4/80

3.4 A

2.0 A

1.1 A

3.3 A

1.9 A

1.1 A

PLURIJET 3/100

3.1 A

1.8 A

1.0 A

3.0 A

1.7 A

1.0 A

PLURIJET 4/100

4.5 A

2.6 A

1.5 A

4.3 A

2.5 A

1.4 A

PLURIJETm 3/80

3.4 A

3.3 A

6.8 A

PLURIJETm 4/80

4.3 A

4.2 A

8.6 A

PLURIJETm 3/100

4.1 A

4.0 A

8.2 A

PLURIJETm 4/100

6.0 A

5.8 A

12.0 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

kg

3~

n° pumps

H (mm)

1~

154

2180

1560

1760

1670

Single-phase

Three-phase

PLURIJETm 3/80

98

1440

980

3~

PLURIJETm 4/80

PLURIJET 4/80

98

1440

1130 1070

154

2180

PLURIJETm 3/100

PLURIJET 3/100

98

1440 1050 1000

154

2180 1640 1560

PLURIJETm 4/100

PLURIJET 4/100

98

1540 1360 1260

140

2140 1940 1800

H

0 80

00

12

125


PLURIJET 90-130-200 Self-priming multi-stage pumps

PERFORMANCE RANGE

•• Flow rate up to 200 l/min (12 m³/h) •• Head up to 97 m

APPLICATION LIMITS

•• Manometric suction lift up to 9 m (HS) •• Liquid temperature between -10 °C and +40 °C •• Ambient temperature up to +40 °C •• Max. working pressure 10 bar •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Suitable for use with clean water even where air is present and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming “PLURIJET” pumps are designed to pump water even in cases where air is present. As a result of their quietness, reliability and low energy consumption they are recommended for use in domestic and civil applications such as the pressurisation and distribution of water in combination with pressure sets, and in rain water recovery and irrigation systems, etc. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

PATENTS - TRADE MARKS - MODELS

•• PLURIJET® is a registered trade mark n° 3974301

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency •• IPX5 class protection

GUARANTEE 1 year subject to terms and conditions

126


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

110

5

0

10 5

15

20

10

50 Hz  n= 2900 1/min  HS= 0 m

25

15

30

20

35

25

40 30

45

50

35

US g.p.m. Imp g.p.m.

40

feet 350

PLURIJET

100 300

90 80 Head H (metres) 4

250

70 200

60 50 40 30

6/90

6/130 5/130

5/90

4/130

150

100

6/200 5/200

3/130

20

4/200 3/200

10 0

0 0

10

20

30

1

40 2

50 3

60

70

80

4

90

100

5

110

6

120 7

130

140

8

150

160

9

170

180

10

190

50

200 l/min

11

12

0

m³/h

Flow rate Q 4 MODEL Single-phase PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 – – PLURIJETm 3/200 PLURIJETm 4/200 – –

POWER

Three-phase PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200

kW 1.1 1.5 1.1 1.5 1.8 2.2 1.1 1.5 1.8 2.2

Q = Flow rate H = Total manometric head HS = Suction height

HP 1.5 2 1.5 2 2.5 3 1.5 2 2.5 3

Q

m³/h

0

l/min

0

76 93 49 65 81 H metres 97 44 58

0.3 5 76 93 49 65 81 97 43.5

0.6

1.2

2.4

3.6

4.8

6.0

10

20

40

60

80

100 130 140 160 180 200

73.5 70 60.5 47 33 90.5 86 74.5 59.5 43 48.5 47.5 45 42.5 38.5 33.5 64 63 60 56 50 43 80.5 79 75 70 62.5 54 96.5 94.5 90 83 74.5 64 43.5 43 42 40.5 38 35

57.5 57.5

57

55

52.5 49.5

7.8

8.4

9.6

10.8 12.0

24 31 39 46 29

27.5

23

18

45

38

35.5

30

24

17

13

73

72

71.5

71

69

65.5

62

56.5

48

44.5

38

30

22

87

86

85.5

85

82

78

73

67

57

53

45

36

26

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

INSTALLATION EXAMPLE

Non-return valve

HS = Suction height

127


PLURIJET 90-130-200 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron and stainless steel AISI 304, complete with threaded ports in compliance with ISO 228/1

2

BODY BACKPLATE

Cast iron

3

IMPELLERS

Noryl GFN2V

4

DIFFUSERS

Stainless steel AISI 304, complete with anti-wear ring

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Seal

Shaft

Model

Diameter

FN-18

Ø 18 mm

Materials Stationary ring

Rotational ring

Elastomer

Graphite

Ceramic

NBR

7

BEARINGS

6304 2RS - C3 / 6204 ZZ

8

CAPACITOR

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

31.5 μF 450 VL

60 μF 250 VL

45 μF 450 VL

80 μF 250 VL

PLURIJETm 5/90 PLURIJETm 3/130 PLURIJETm 3/200 PLURIJETm 6/90 PLURIJETm 4/130 PLURIJETm 4/200 9

ELECTRIC MOTOR

PLURIJETm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. PLURIJET: three-phase 230/400 V - 50 Hz. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IP X4.

4

1

128

3

2

5

7

8

6

9

7


DIMENSIONS AND WEIGHT f

n

h1

h

DN1

h2

DN2

s w

a

MODEL

n1

PORTS DN1

Single-phase

Three-phase

PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 – – PLURIJETm 3/200 PLURIJETm 4/200 – –

PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200

DIMENSIONS mm

DN2

1¼”

1”

a

f

69

634 665 571 602 634 665 571 602 634 665

h

h1

230

153

h2

46

kg

n

185

n1

w

145

304 335 241 272 304 335 241 272 304 335

s

1~

3~

10

26.6 28.7 24.8 26.9 – – 24.8 26.9 – –

24.8 27.8 22.9 25.9 27.9 28.8 22.9 25.9 27.9 28.8

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 PLURIJETm 3/200 PLURIJETm 4/200

8.5 A 10.5 A 8.5 A 10.5 A 8.5 A 10.5 A

8.2 A 10.0 A 8.2 A 10.0 A 8.2 A 10.0 A

17.0 A 21.0 A 17.0 A 21.0 A 17.0 A 21.0 A

PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200

5.7 A 8.1 A 5.7 A 8.5 A 8.7 A 10.4 A 5.7 A 8.1 A 8.7 A 10.4 A

3.3 A 4.7 A 3.3 A 4.9 A 5.0 A 6.0 A 3.3 A 4.7 A 5.0 A 6.0 A

1.9 A 2.7 A 1.9 A 2.8 A 2.9 A 3.5 A 1.9 A 2.7 A 2.9 A 3.5 A

5.5 A 7.8 A 5.5 A 8.1 A 8.3 A 10.0 A 5.5 A 7.8 A 8.3 A 10.0 A

3.2 A 4.5 A 3.2 A 4.7 A 4.8 A 5.8 A 3.2 A 4.5 A 4.8 A 5.8 A

1.8 A 2.6 A 1.8 A 2.7 A 2.8 A 3.4 A 1.8 A 2.6 A 2.8 A 3.4 A

PALLETIZATION MODEL Three-phase PLURIJET 5/90 PLURIJET 6/90 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130 PLURIJET 3/200 PLURIJET 4/200 PLURIJET 5/200 PLURIJET 6/200

n° pumps 30 30 40 40 30 30 40 40 30 30

H (mm) 1430 1430 1430 1430 1430 1430 1430 1430 1430 1430

kg 1~ 820 880 1010 1100 – – 1010 1100 – –

3~ 760 850 940 1060 860 880 940 1060 860 880

H

0 80

Single-phase PLURIJETm 5/90 PLURIJETm 6/90 PLURIJETm 3/130 PLURIJETm 4/130 – – PLURIJETm 3/200 PLURIJETm 4/200 – –

GROUPAGE / CONTAINER

00

12

129


F

Standardised “EN 733” centrifugal pumps

PERFORMANCE RANGE

•• Flow rate up to 6000 l/min (360 m³/h) •• Head up to 95 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. pressure in pump body 10 bar (PN10) •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 Pump body dimensions in compliance with EN 733 REGULATION (EU) N. 547/2012

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

130

INSTALLATION AND USE

•• Water supply •• Pressure boosting •• Irrigation •• Water circulation in climatisation sets

•• Cleaning sets •• Firefighting sets •• Industrial applications •• Agricultural applications

The pumps must be installed in enclosed places, or at least protected against inclement weather.

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• Compatibility with hotter or colder liquids •• Compatibility with hotter or colder ambients

GUARANTEE 1 year subject to terms and conditions


PERFORMANCE RANGE 30

50 Hz  n= 2900 1/min  HS= 0 m

50

100 50

100

200 100

500 200

1600 US g.p.m.

1000 500

1000

1400 Imp. g.p.m. 300

90 F40/250

80

F50/250

F65/250 250

70 F50/200

60

F80/250

F100/250

200

50 150

F32/200H

Head H (metres) 4

40

F32/200

F40/200 F65/200

F80/200 F100/200

H feet 100

30 F50/160

F32/160

20

100 6

200 7

8

9 10

F80/160

F40/160

F50/125

10

F65/160

400

600 30

F65/125

800 1000 40

50

2000 100

50

F100/160

3000 4000 5000 200

300

l/min 400 m 3 /h

Flow rate Q 4

131


F 32/ 160 50 Hz  n= 2900 1/min  HS= 0 m

H (feet) 25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

8

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

CHARACTERISTIC CURVES AND PERFORMANCE DATA

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase

kW

HP

Fm 32/160C

F 32/160C

1.5

2

Fm 32/160B

F 32/160B

2.2

3

F 32/160A

3

4

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

132

0

6

9

12

15

18

21

24

27

400

450

0

100

150

200

250

300

350

25

24

23.5

22

20.5

18

14

31

30

29

28

26

23.5

20.5

17

38

37

36

35

33.5

31.5

30

27.5

24

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 32/200 50 Hz  n= 2900 1/min  HS= 0 m

H (feet) 25

6

20 15

4

10

2

5

0

0

NPSH (feet)

8

Absorbed power P2 (kW)

A B

P2 (HP)

NPSH (metres)

Head H (metres) 4

CHARACTERISTIC CURVES AND PERFORMANCE DATA

C

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 32/200C

4

5.5

F 32/200B

5.5

7.5

F 32/200A

7.5

10

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

0

6

9

12

15

18

21

24

27

30

0

100

150

200

250

300

350

46

44

43

41.5

40

38

36

400

450

500

34

31.5

52

51

50.5

49

47

45

43

41

38.5

36

60

57

56.5

56

55

53.5

52

50

47

44

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

133


F 32/200H CHARACTERISTIC CURVES AND PERFORMANCE DATA 20

30

40

20

50 Hz  n= 2900 1/min  HS= 0 m

50

30

60

40

70

50

80 60

70

8

25

6

20 15

4

10

2

5

0 4.5

0 6

AH

NPSH (feet)

H (feet)

F32/200BH

5.5

4

5

BH

3.5

4.5

3

4 3.5

2.5

P2 (HP)

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F32/200AH

3

2 1.5

2.5

50

100

150

200

250

300

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 32/200BH

3

4

F 32/200AH

4

5.5

Q

m³/h

0

6

9

12

15

18

19.2

l/min

0

100

150

200

250

300

320

47

45

44.5

43

40.5

37

57

55

54

52.5

50

46

H metres

Q = Flow rate H = Total manometric head HS = Suction height

134

44

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 40/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F40/160A

H (feet)

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

F40/160C

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F40/160B

Flow rate Q 4

MODEL Single-phase Three-phase Fm 40/160C F 40/160C – F 40/160B – F 40/160A

POWER kW 2.2 3 4

HP 3 4 5.5

Q

m³/h

0

6

9

12

15

18

24

30

36

42

l/min

0

100

150

200

250

300

400

500

600

700

27

27

26.5

26

25.5

25

22.5

19

14

32

32

31.5

31

30.5

30

27.5

24

20

38

38

37.8

37

36.5

36

33.5

30

26

H metres

Q = Flow rate H = Total manometric head HS = Suction height

20

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

135


F 40/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F40/200A

H (feet) 25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

8

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F40/200B

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 40/200B

5.5

7.5

F 40/200A

7.5

10

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

136

0

6

9

12

15

18

24

30

36

42

0

100

150

200

250

300

400

500

600

700

48

47

46.5

46

45.5

44.5

42

38

34

28

56

55

55

55

54.5

54

52.5

49.5

46

41

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 40/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F40/250C

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

H (feet)

F40/250B

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F40/250A

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 40/250C

9.2

12.5

F 40/250B

11

15

F 40/250A

15

20

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

0

6

9

12

0 64

15

18

24

30

100

150

64

63.5

71

71

88

88

36

42

200

250

300

400

63

62.5

62

60

500

600

700

56.5

52.5

47

70.5

70

69.5

69

87.5

87

86.5

86

67

64

60

55

84

81

77

72

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

137


F 50/125 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F50/125A

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

H (feet)

F50/125C

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F50/125B

Flow rate Q 4

MODEL

POWER

Q

m³/h

0

18

24

30

36

42

48

54

60

66

72

Single-phase

Three-phase

kW

HP

0

300

400

500

600

700

800

900

1000

1100

1200

Fm 50/125C

F 50/125C

2.2

3

18.5

17.5

17

16.5

15.5

14.8

13.5

12

10.5

8.2

6

F 50/125B

3

4

H metres 21.5

20.7

20

19.5

18.8

17.8

16.5

15

13.5

11.2

9

F 50/125A

4

5.5

24.5

23.5

23

22.5

21.8

20.8

19.5

18.3

16.8

15

13

Q = Flow rate H = Total manometric head HS = Suction height

138

l/min

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 50/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F50/160A

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

H (feet)

F50/160C

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F50/160B

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 50/160C

4

5.5

F 50/160B

5.5

7.5

F 50/160A

7.5

10

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

0

18

24

30

36

42

48

54

60

66 1100

0

300

400

500

600

700

800

900

1000

27

27

26.5

25

24.5

23

20

18.5

16

33

32

31.7

31

30

29

27

26

24

21

38

37

36.8

36.5

36

34

33

32

30

27

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

139


F 50/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F50/200AR

H (feet)

F50/200B

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

F50/200C

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F50/200A

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 50/200C

11

15

F 50/200B

15

20

F 50/200A

18.5

25

F 50/200AR

22

30

Q

m³/h

24

36

48

60

72

84

96

102

108

l/min

400

600

800

1000

1200

1400

1600

1700

1800

44

44

44

42

39

36

33

30

52

52

52

50

47

44

40

38

61

61

60.5

60

57

54

50

48

45

69

69

68.5

68

65

62

58

56

53

H metres

Q = Flow rate H = Total manometric head HS = Suction height

140

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 50/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

100 F50/250AR

90 F50/250A

70

F50/250B

60

F50/250C

50

F50/250D

H (feet)

Head H (metres) 4

80

40 30

8

25

6

20 15

4

10

2

5 0

20

P2 (HP)

Absorbed power P2 (kW)

0 25

NPSH (feet)

NPSH (metres)

20

15 10 5

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 50/250D

9.2

12.5

F 50/250C

11

15

F 50/250B

15

20

F 50/250A

18.5

F 50/250AR

22

Q

m³/h l/min

0

18

24

30

36

42

48

54

60

0

300

400

500

600

700

800

900

1000

51

51

49

47

44

41

37

32

59

59

58

57

54

51

47

42

72

72

71

70

69

67

65

62

25

85

85

84

83

82

80

78

76

73

30

95

95

94

93

92

90

88

86

83

H metres

Q = Flow rate H = Total manometric head HS = Suction height

59

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

141


F 65/125 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

H (feet)

F65/125B

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

F65/125C

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F65/125A

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 65/125C

4

5.5

F 65/125B

5.5

7.5

F 65/125A

7.5

10

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

142

0

36

48

60

72

84

96

108

120

132

0

600

800

1000

1200

1400

1600

1800

2000

2200

16

16

16

15.5

14.5

13.5

12.5

11

18

18

18

18

17

16.5

15.5

14.5

13

23

23

23

23

22.5

22.5

22

21

19.5

18

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 65/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F65/160A

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

H (feet)

F65/160C

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F65/160B

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 65/160C

9.2

12.5

F 65/160B

11

15

F 65/160A

15

20

Q

0

36

48

60

72

84

96

108

120

132

144

0

600

800

1000

1200

1400

1600

1800

2000

2200

2400

32

32

32

32

32

30

29

27

25

22

m³/h l/min

H metres

37

36.5

36.5

36

35.5

34

33

31

29

26

23

41

40.5

40.5

40

39.5

39

37.5

36

34

31

28

Q = Flow rate H = Total manometric head HS = Suction height

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

143


F 65/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

200

300

100

400

200

400

600

US g.p.m.

500

Imp g.p.m. feet

F65/200AR

60 70

55

75

175 80

F65/200A

50

Head H (metres) 4

500

300

81

η = 82%

45 F65/200B

150

81

40 125

H (feet)

60

100

0

50 Hz  n= 2900 1/min  HS= 0 m

35

100

30

25 75

20

6

15

4

10

2

5

0 25

0

30

20 25

15

20 15

10

10

5

0

200

400

0

MODEL

600

800

25

1000

1200

50

POWER

Three-phase

kW

HP

F 65/200B

15

20

F 65/200A

18.5

25

F 65/200AR

22

30

Q

75

m³/h

12

l/min

200

400

44

43.5

50

50

57

57

H metres

1400

1600

Flow rate Q 4

Q = Flow rate H = Total manometric head HS = Suction height

144

NPSH (feet)

25

8

P2 (HP)

Absorbed power P2 (kW)

NPSH (metres)

20

24

36

1800

2000

100

2200

2400

125

l/min

2600

m³/h

150

48

60

72

84

96

108

120

132

144

156

600

800

1000

1200

1400

1600

1800

2000

2200

2400

2600

43.5

43.3

43

42.5

41.5

40

38.5

36.5

34

30.5

50

50

49.5

49

48

46.5

45

43

41

38

36.5

57

57

56

55.5

54.5

53.5

52

50

48

45.5

42

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 65/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

200 100

300 200

400

500

300

700

500

US g.p.m. 600

Imp g.p.m.

58

F65/250A

65

300

70

90

72

F65/250B

Head H (metres) 4

600

400

η=73%

80 F65/250C

72

250

H (feet)

100

100

0

50 Hz  n= 2900 1/min  HS= 0 m

70

70

200

60

50 150

25

6

20 15

4

10

2

5

Absorbed power P2 (kW)

0

0 60

A

40

B

30

NPSH (feet)

8

50

C

40 30

20

P2 (HP)

NPSH (metres)

40

20

10 0

10

0 0

500 20

1000 40

60

1500

2000

80

100

2500

120

140

l/min 160

m³/h

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 65/250C

30

40

F 65/250B

37

50

F 65/250A

45

60

Q

m³/h

24

40

60

80

100

120

141

150

156

l/min

400

667

1000

1333

1667

2000

2350

2500

2600

76

76

75.5

72.5

68

61.5

53

H metres

Q = Flow rate H = Total manometric head HS = Suction height

87

87

86

84

80

74

66.5

62

94.5

95

94

92

88

82.5

75

71

68

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

145


F 80 /160 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F80/160A

F80/160B

H (feet)

F80/160D

P2 (HP)

Absorbed power P2 (kW)

NPSH (feet)

NPSH (metres)

Head H (metres) 4

F80/160C

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 80/160D

11

15

F 80/160C

15

20

F 80/160B

18.5

25

F 80/160A

22

30

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

146

0

30

60

90

120

150

180

210

240

0

500

1000

1500

2000

2500

3000

3500

4000

25

25

25

24.5

23.5

21

18

14.5

10

30

30

30

29.5

28.5

26

23

19.5

15

35

35

35

34.5

33.5

31

28.5

24.5

20

40

40

40

39.5

38.5

36

33

29.5

25

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 80/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

70

200

0

400

50 Hz  n= 2900 1/min  HS= 0 m

600

200

800

400

1000

600

800

1200

US g.p.m.

1000

Imp g.p.m. 220

F80/200A 200

60 F80/200B

50

160

140

H (feet)

Head H (metres) 4

180

40 120

100

30

80

25

6

20 15

4

10

2

5

Absorbed power P2 (kW)

0

0

40

50

A

30

40

B

30

20

20

10

0

NPSH (feet)

8

P2 (HP)

NPSH (metres)

20

10

0

500

1000

0

1500

50

2000 100

2500

3000

150

3500 200

4000

4500

l/min m³/h

250

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 80/200B

30

40

F 80/200A

37

50

Q

m³/h

30

50

100

150

200

219

234

l/min

500

833

1667

2500

3333

3650

3900

56

56

54

49

41

34.5

62

62

61

57

50

45.5

H metres

Q = Flow rate H = Total manometric head HS = Suction height

40

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

147


F 80/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

100

200

0

400

50 Hz  n= 2900 1/min  HS= 0 m

600

200

800

400

1000

600

800

1200

US g.p.m.

1000

Imp g.p.m. 320

90

F80/250A

70

280

75 76

F80/250B

η=77% 240 75

70

71 69

200

60

50

H (feet)

Head H (metres) 4

80

160

40 120

25

6

20 15

4

10

2

5

0 60

0 80

A

NPSH (feet)

8

50 60

B

40 30

40

P2 (HP)

Absorbed power P2 (kW)

NPSH (metres)

30

20 20

10 0

0

500

0

1000

1500

50

2000

2500

100

3000

150

3500 200

4000

4500

l/min

0

m³/h

250

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 80/250B

45

60

F 80/250A

55

75

Q

m³/h

36

l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

148

50

100

150

200

216

234

600

833

1667

2500

3333

3600

3900

77

77.5

76

70.5

58.5

54

88.5

89.5

89

83

72

68

60

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 100/160 CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F100/160A 65

F100/160B

69

70

F100/160C

Head H (metres) 4

71

H (feet)

η = 75% 71 70 69

NPSH (feet)

NPSH (metres)

65

Absorbed power P2 (kW)

A

P2 (HP)

B C

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 100/160C

15

20

F 100/160B

18.5

25

F 100/160A

22

30

Q

m³/h

60

120

180

240

270

300

330

360

l/min

1000

2000

3000

4000

4500

5000

5500

6000

28

25.5

22

17.5

15

12

32

30

27

22.5

19.5

17

13

35

34

31

27

24.5

22

18

H metres

Q = Flow rate H = Total manometric head HS = Suction height

15

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

149


F 100/200 CHARACTERISTIC CURVES AND PERFORMANCE DATA 200

0

65

400

600

200

0

800

400

F100/200A

50 Hz  n= 2900 1/min  HS= 0 m 1000

600

1400

1000

US g.p.m. 1200 Imp. g.p.m.

60

200

71

60

75

F100/200B

79

55

80.5

180

η = 81%

F100/200C

50

160 80.5

45

79

80.5

140

H (feet)

Head H (metres) 4

1200

800

75

40

79

120

35

30

100

71

25

6

20 15

4

10

2

5

Absorbed power P2 (kW)

0 50

NPSH (feet)

8

0 60

A

40

50

B C

30

40 30

20

P2 (HP)

NPSH (metres)

25

20

10 0

10

0

500

1000

1500

50

0

2000 100

2500

3000

150

3500

4000

200

4500

5000

250

5500 l/min

300

m³/h

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 100/200C

30

40

F 100/200B

37

50

F 100/200A

45

60

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

150

0

50

100

150

200

250

279

294

300

315

0

833

1667

2500

3333

4167

4650

4900

5000

5250

51

51

50

47

41.5

34

28 41.5

38

57

57

56

53

48

41

36

33

63

63

62.5

60

56

50

45

42.5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 100/250 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

100

200

0

400

600

200

50 Hz  n= 2900 1/min  HS= 0 m

800

400

1000

600

1200

800

1400

1000

1600

US g.p.m. Imp g.p.m.

1200

300

90

65

F100/250A

72

75 78

η = 80% 250

F100/250B 78

70

75

η = 79.5%

200

71

60

H (feet)

Head H (metres) 4

80

50 150

40

100

6

20

4

10

2

Absorbed power P2 (kW)

0 80

NPSH (feet)

30

8

0

A

60

100

80

B

60

40

P2 (HP)

NPSH (metres)

30 10

40

20

0 0

500

1000

1500

50

2000

2500

100

3000

150

3500 200

4000

4500

5000

250

5500

300

6000 350

l/min m³/h

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 100/250B

55

75

F 100/250A

75

100

Q

m³/h

48

96

150

180

210

240

300

309

345

l/min

800

1600

2500

3000

3500

4000

5000

5150

5750

75

75

74

71.5

69

64.5

51

48

89

89

88.5

87

84

80.5

70.5

69

H metres

Q = Flow rate H = Total manometric head HS = Suction height

58

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

151


F POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with flanged suction and delivery ports

2

COUNTERFLANGES

Steel, complete with ISO 228/1 thread

3a

BODY BACKPLATE

Cast iron

3b

MOTOR BRACKET

Cast iron

4

IMPELLER

Brass for F32/160, F32/200, F40/160, F40/200, F50/125, F50/160 Cast iron for F40/250, F50/200, F50/250, F65/125, F65/160, F65/200, F65/250, F80/160, F80/200, F80/250, F100/160, F100/200, F100/250

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

FN-20

F32/160 F50/125 F32/200 F50/160 F50/200 F65/200 F100/160 F40/250 F65/250 F80/250B F80/250A 7

BEARINGS

Pump F32/160C F32/160B F40/160C F50/125C Fm32/160B F32/160A Fm40/160C F40/160B Fm50/125C F50/125B F40/160A F50/125A

8

9

CAPACITOR

ELECTRIC MOTOR

F40/160 F40/200 F65/125 F65/160 F80/160 F50/250 F80/200 F100/200 F100/250

Rotational ring

Elastomer

Ø 20 mm

Graphite

Ceramic

NBR

FN-24

Ø 24 mm

Graphite

Ceramic

NBR

FN-32 NU

Ø 32 mm

Graphite

Ceramic

NBR

FN-38

Ø 38 mm

Graphite

Ceramic

NBR

FN-40 NU

Ø 40 mm

Graphite

Ceramic

NBR

FH-45 NU

Ø 45 mm

Graphite

Ceramic

NBR

Model

6206 ZZ - C3 / 6204 ZZ

6206 ZZ - C3 / 6205 ZZ

6306 ZZ - C3 / 6206 ZZ - C3

Pump

Materials Stationary ring

Pump F32/200 F40/200 F50/160 F65/125 F40/250 F50/200 F50/250 F65/160 F65/200 F80/160 F100/160 F65/250 F80/200 F80/250B F100/200 F80/250A F100/250

Model 6307 ZZ - C3 / 6206 ZZ - C3

6310 ZZ - C3 / 6308 ZZ - C3

6312 ZZ - C3 / 6212 ZZ - C3 6314 ZZ - C3 / 6314 ZZ - C3

Capacitance

Single-phase

(230 V or 240 V)

Fm32/160C Fm32/160B Fm40/160C Fm50/125C

45 μF 450 VL 70 μF 450 VL 70 μF 450 VL 70 μF 450 VL

Fm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding (up to 1.5 kW) F: three-phase 230/400 V - 50 Hz up to 4 kW 400/690 V - 50 Hz from 5.5 to 75 kW ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class   – Protection: IPX5

152


7

7

8

2

1

4

3a

6

5

9

Single-phase version

7

7

2

1

4

6

3b

5

9

Three-phase version

153


F DIMENSIONS AND WEIGHT f

n

a

h1

DN1

h

h2

DN2

w1 w2

n1

s

n2

MODEL Single-phase

Three-phase

Fm 32/160C Fm 32/160B – – – – – – Fm 40/160C – – – – – – – Fm 50/125C – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

F 32/160C F 32/160B F 32/160A F 32/200C F 32/200B F 32/200A F 32/200BH F 32/200AH F 40/160C F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A F 50/125C F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 80/160D F 80/160C F 80/160B F 80/160A F 100/160C F 100/160B F 100/160A

154

PORTS DN1

50

DN2

DIMENSIONS mm a

f 412 448/412 448 469

32 80

h

h1

h2

n

292

132

160

242

340

160

180

270

448/412 448 465

292

132

160

240

535

340

160

180

405

180

292

132

515

n1

kg * n2

190

240

275

212

265

225

328

250

320

160

242

190

240

180

269 212

265

200

316

225

337

250

320

180

291 212

280

200

300

250

320

280

360

469

65

40

606 701 465/431 465 484 489 535 65

340

616

50

711 100

160 360

743 606 701

405

180

733 511 557

340 160

80

621

65

360

716 719 751 652 100

80

100

405

180

225

747 125

125

340

330

779 758 790

480

200

280

362

w1

w2

s

1~

3~

39.2 37.0 42.6 38.5 – 42.6 – 52.0 – 57.0 – 61.0 – 47.9 35 35 – 51.1 43.9 40.0 – 44.0 – 50.1 – 61.0 – 67.0 – 103.0 47.5 47.5 – 109.0 – 125.0 44.2 40.1 – 44.1 – 50.7 – 55.0 – 60.6 35 35 – 64.7 14 – 106.0 – 128.0 – 135.0 – 147.0 – 106.0 – 113.4 – 129.6 – 146.0 – 155.0 – 62.7 – 66.8 – 74.0 – 100.0 47.5 47.5 – 106.5 – 123.0 – 128.0 – 125.0 – 153.1 – 111.5 – 126.0 – 143.5 – 153.0 – 139.0 60 60 18 – 153.7 – 165.0 (*weight includes counterflanges)


DIMENSIONS AND WEIGHT f a DN2

h1

DN1

h

h2

n

h3

s w

32 40 50 65 80 100 125

D mm 140 150 165 185 200 220 250

K mm 100 110 125 145 160 180 210

a

f

h

DN

FLANGES

MODEL

n1 n2

m

HOLES N° Ø (mm) FLANGES

4 18

DN K D

8

PORTS

Three-phase F 65/250C F 65/250B F 65/250A F 80/200B F 80/200A F 80/250B F 80/250A F 100/200C F 100/200B F 100/200A F 100/250B F 100/250A

DN1 80

DIMENSIONS mm

DN2 65

100

100

80 125

125

100 140

796 847 847 824 875 872 1015 824 875 875 1036

h1

h2

h3

450 200

n

15

369

25

360

280

12 55

250

430

kg * n1

n2

w

m

s

318

360

269.5

305

18.5

380 490

400

490

294

350

24

480 620

250

480

200

280

0

391

318

360

269.5

305

18.5

620

250

280

45

490

400

490

300

350

24

3~ 210.0 230.0 230.0 212.0 222.5 245.0 497.0 208.5 239.0 240.0 498.5 498.5

(*weight includes counterflanges)

COUNTERFLANGES DN FLANGES

F COUNTERFLANGES

D mm

K mm

32 40 50 65 80 100 125

1¼" 1½" 2" 2½" 3" 4" 5"

140 150 165 185 200 220 250

100 110 125 145 160 180 210

HOLES N°

Ø (mm)

4 18 8

F K D

155


F ABSORPTION MODEL Single-phase Fm 32/160C Fm 32/160B Fm 40/160C Fm 50/125C

VOLTAGE (single-phase) 230 V 11.0 A 15.0 A 15.0 A 15.0 A

CAPACITOR

Single-phase version

Three-phase version

156

240 V 10.0 A 13.8 A 13.8 A 13.8 A

MODEL Three-phase F 32/160C F 32/160B F 32/160A F 32/200C F 32/200B F 32/200A F 32/200BH F 32/200AH F 40/160C F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A F 50/125C F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 65/250C F 65/250B F 65/250A F 80/160D F 80/160C F 80/160B F 80/160A F 80/200B F 80/200A F 80/250B F 80/250A F 100/160C F 100/160B F 100/160A F 100/200C F 100/200B F 100/200A F 100/250B F 100/250A

VOLTAGE (three-phase) 230÷240 V

400÷415 V

690÷720 V

7.5 A 10.0 A 12.0 A 17.9 A – – 12.6 A 15.4 A 9.9 A 12.0 A 17.2 A – – – – – 9.4 A 12.0 A 16.3 A 15.8 A – – – – – – – – – – – 17.5 A – – – – – – – – – – – – – – – – – – – – – – – – – – –

4.3 A 5.8 A 7.3 A 10.3 A 11.7 A 14.9 A 7.3 A 8.9 A 5.7 A 6.9 A 9.9 A 12.6 A 15.6 A 21.0 A 23.5 A 30.5 A 5.4 A 6.9 A 9.4 A 9.1 A 12.3 A 15.5 A 23 A 29.5 A 34.5 A 41.5 A 17.2 A 21.0 A 27.0 A 34.0 A 41.0 A 10.0 A 12.0 A 16.5 A 19.0 A 23.0 A 27.5 A 31.0 A 34.0 A 41.0 A 53.0 A 65.0 A 79.0 A 22.0 A 29.0 A 34.5 A 39.0 A 53.0 A 65.0 A 79.0 A 98.0 A 31.0 A 36.0 A 42.0 A 53.0 A 65.0 A 79.0 A 98.0 A 126.0A

2.5 A 3.4 A 4.2 A 5.9 A 6.7 A 8.6 A 4.2 A 5.1 A 3.3 A 4.0 A 5.7 A 7.3 A 9.0 A 12.1 A 13.6 A 17.6 A 3.1 A 4.0 A 5.4 A 5.3 A 7.1 A 8.9 A 13.3 A 17 A 20 A 24 A 9.9 A 12.0 A 15.6 A 19.6 A 24.0 A 5.8 A 7.0 A 9.5 A 11.0 A 13.5 A 16.0 A 18.0 A 19.5 A 23.7 A 31.0 A 38.0 A 46.0 A 13.0 A 17.0 A 20.0 A 22.5 A 31.0 A 38.0 A 46.0 A 57.0 A 18.0 A 21.0 A 24.0 A 31.0 A 38.0 A 46.0 A 57.0 A 73.0 A


PALLETIZATION MODEL

GROUPAGE

Fm 32/160C Fm 32/160B – – – – – – Fm 40/160C – – – – – – – – Fm 50/125C – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

F 32/160C F 32/160B F 32/160A F 32/200C F 32/200B F 32/200A F 32/200BH F 32/200AH – F 40/160C F 40/160B F 40/160A F 40/200B F 40/200A F 40/250C F 40/250B F 40/250A – F 50/125C F 50/125B F 50/125A F 50/160C F 50/160B F 50/160A F 50/200C F 50/200B F 50/200A F 50/200AR F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR F 65/125C F 65/125B F 65/125A F 65/160C F 65/160B F 65/160A F 65/200B F 65/200A F 65/200AR F 65/250C F 65/250B F 65/250A F 80/160D F 80/160C F 80/160B F 80/160A F 80/200B F 80/200A F 80/250B F 80/250A F 100/160C F 100/160B F 100/160A F 100/200C F 100/200B F 100/200A F 100/250B F 100/250A

18 18 18 12 12 12 12 12 12 18 18 12 12 12 6 6 6 18 12 18 12 12 12 12 6 6 6 6 6 6 6 6 6 12 12 12 6 6 6 6 6 6 1 1 1 6 6 6 6 1 1 1 1 6 6 6 1 1 1 1 1

1~

3~

n° pumps

1430 1430 1430 1535 1535 1535 1535 1535 1400 1430 1430 1400 1535 1535 1200 1200 1200 1430 1400 1430 1535 1535 1535 1535 1200 1200 1200 1380 1200 1200 1200 1200 1380 1535 1535 1535 1200 1200 1200 1200 1200 1380 450 450 450 1200 1380 1380 1380 450 450 450 770 1380 1380 1380 450 450 450 770 770

730 781 – – – – – – 509 – – – – – – – – 820 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –

683 707 784 641 701 749 591 629 – 735 809 617 749 821 635 671 767 – 498 810 625 677 744 793 653 785 827 899 653 697 794 893 947 769 818 905 617 656 755 785 767 936 227 247 247 686 773 878 935 229 240 262 514 851 939 1007 226 256 257 516 516

24 24 24 16 16 16 16 16 16 24 24 16 16 16 9 9 9 24 16 24 16 16 16 16 9 9 9 9 9 9 9 9 9 16 16 16 9 9 9 9 9 9 – – – 9 9 9 9 – – – – 9 9 9 – – – – –

H (mm)

kg 1~

3~

1860 967 905 1860 1036 936 1860 – 1040 2000 – 849 2000 – 929 2000 – 993 2000 – 783 2000 – 833 1820 673 – 1860 – 975 1860 – 1073 1820 – 817 2000 – 993 2000 – 1089 1730 – 944 1730 – 998 1730 – 1142 1860 1088 – 1820 – 659 1860 – 1075 2000 – 828 2000 – 897 2000 – 987 2000 – 1052 1730 – 971 1730 – 1169 1730 – 1232 200 – 1340 1730 – 971 1730 – 1037 1730 – 1183 1730 – 1331 2000 – 1412 2000 – 1020 2000 – 1085 2000 – 1201 1730 – 917 976 1730 – 1730 – 1018 1730 – 1169 1730 – 1142 2000 – 1395 – – – – – – – – – 1730 – 1021 2000 – 1151 2000 – 1309 2000 – 1394 – – – – – – – – – – – – 2000 – 1256 2000 – 1437 2000 – 1502 – – – – – – – – – – – – – – –

H

0

Three-phase

CONTAINER kg

H (mm)

80

Single-phase

n° pumps

00

12

157


F-I Stainless steel standardised “EN 733” pumps

PERFORMANCE RANGE

•• Flow rate up to 2200 l/min (132 m³/h) •• Head up to 38 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Ambient temperature between -10 °C and +40 °C •• Max. pressure in pump body 10 bar (PN10) •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3 Pump body dimensions in compliance with: EN 733

INSTALLATION AND USE

•• Water supply •• Pressure boosting •• Irrigation •• Water circulation in climatisation sets

Suitable for use with clean, aggressive liquids that are chemically compatible with the materials from which the pump is made. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather.

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Other voltages or 60 Hz frequency •• Compatibility with hotter or colder liquids •• Compatibility with hotter or colder ambients

REGULATION (EU) N. 547/2012

GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

158

•• Cleaning sets •• Firefighting sets •• Industrial applications •• Agricultural applications

1 year subject to terms and conditions


PERFORMANCE RANGE 30

50 Hz  n= 2900 1/min  HS= 0 m 50

100 50

50

200

US g.p.m.

500

100

200

500

Imp. g.p.m. feet 150

40

F50/160-I

Head H (metres) 4

30

100

F65/125-I

20

50

10

100 6

200 7

8

9

10

400

600 30

800 40

50

2000

1000 100

l/min m 3/h

Flow rate Q 4

159


F 50/160-I CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

F50/160A-I

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

H (feet)

F50/160C-I

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F50/160B-I

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 50/160C-I

4

5.5

F 50/160B-I

5.5

7.5

F 50/160A-I

7.5

10

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

160

0

18

24

30

36

42

48

54

60

66 1100

0

300

400

500

600

700

800

900

1000

27

27

26.5

25

24.5

23

20

18.5

16

33

32

31.7

31

30

29

27

26

24

21

38

37

36.8

36.5

36

34

33

32

30

27

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


F 65/125-I CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

H (feet)

F65/125B-I

8

25

6

20 15

4

10

2

5

0

0

P2 (HP)

NPSH (feet)

F65/125C-I

Absorbed power P2 (kW)

NPSH (metres)

Head H (metres) 4

F65/125A-I

Flow rate Q 4

MODEL

POWER

Three-phase

kW

HP

F 65/125C-I

4

5.5

F 65/125B-I

5.5

7.5

F 65/125A-I

7.5

10

Q

m³/h l/min

H metres

Q = Flow rate H = Total manometric head HS = Suction height

0

36

48

60

72

84

96

108

120

132

0

600

800

1000

1200

1400

1600

1800

2000

2200

16

16

16

15.5

14.5

13.5

12.5

11

18

18

18

18

17

16.5

15.5

14.5

13

23

23

23

23

22.5

22.5

22

21

19.5

18

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

161


F-I POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 316, complete with flanged suction and delivery ports

2

BODY BACKPLATE

Stainless steel AISI 316

4

IMPELLER

Stainless steel AISI 316

5

MOTOR SHAFT

Stainless steel AISI 316

6

MECHANICAL SEAL

Pump

Seal

Shaft

Model

Model

Diameter

F50/160-I F65/125-I

FN-24SV

Ø 24 mm

7

9

BEARINGS

ELECTRIC MOTOR

Pump

Model

F50/160-I F65/125-I

6307 ZZ - C3 / 6206 ZZ - C3

Materials Stationary ring

Rotational ring

Elastomer

Silicon carbide

Silicon carbide

Viton

F: three-phase 230/400 V - 50 Hz for 4 kW. 400/690 V - 50 Hz from 5.5 to 7.5 kW. ➠ Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance – Insulation: F class.   – Protection: IPX5.

6

1

162

3

2

5

6

4

7


DIMENSIONS AND WEIGHT f

n

a

h1

h

DN1

h2

DN2

s

n1

w1 w2

n2

MODEL Three-phase

PORTS DN1

DIMENSIONS mm

DN2

a

f

F 50/160C-I F 50/160B-I

h1

h2

n

n1

kg n2

w1

w2

s

65

50 100

80

269

535

F 65/125C-I

511

65

340

160

180

265

35

54.0

35

212 291

557

F 65/125A-I

3~ 50.2

489

F 50/160A-I F 65/125B-I

h

14 280

47.5

65.5 62.6 67.7

47.5

72.9

ABSORPTION MODEL

VOLTAGE (three-phase)

Three-phase

230÷240 V

400÷415 V

690÷720 V

F 50/160C-I F 50/160B-I F 50/160A-I F 65/125C-I F 65/125B-I F 65/125A-I

15.8 A – – 17.5 A – –

9.1 A 12.3 A 15.5 A 10.0 A 12.0 A 16.5 A

5.3 A 7.1 A 8.9 A 5.8 A 7.0 A 9.5 A

PALLETIZATION GROUPAGE

MODEL

CONTAINER

n° pumps

H (mm)

kg 3~

n° pumps

H (mm)

kg 3~

F 50/160C-I

12

1535

619

16

2000

820

F 50/160B-I

12

1535

665

16

2000

881 1064

Three-phase

12

1535

802

16

2000

12

1535

768

16

2000

1018

F 65/125B-I

12

1535

829

16

2000

1100

F 65/125A-I

12

1535

891

16

2000

1183

0 80

F 50/160A-I F 65/125C-I

H

00

12

163


FG Standardised “EN 733” centrifugal pumps

PERFORMANCE RANGE

•• Flow rate up to 6000 l/min (360 m³/h) •• Head up to 95 m

APPLICATION LIMITS

•• Manometric suction lift up to 7 m •• Liquid temperature between -10 °C and +90 °C •• Max. pressure in pump body 10 bar (PN10)

CONSTRUCTION AND SAFETY STANDARDS EN 733

INSTALLATION AND USE

•• Water supply •• Pressure boosting •• Irrigation •• Water circulation in climatisation sets

•• Cleaning sets •• Firefighting sets •• Industrial applications •• Agricultural applications

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Counterflange •• Pumps compatible with 60 Hz motors •• Compatibility with hotter or colder liquids •• Compatibility with hotter or colder ambients

REGULATION (EU) N. 547/2012

GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

164

1 year subject to terms and conditions


FG2

n= 2900 1/min

PERFORMANCE RANGE 30

HS= 0 m

50

100 50

100 90

200 100

500 200

1000 500

1000

1400 Imp. g.p.m. 300

50

FG2-65/250

FG2-50/200

FG2-80/250

0/2

FG2-40/250

200

FG 2

60

-10

70

50

150

-10 FG2-65/160

FG2-65/125

6

7

8

400

9 10

600 30

800

40

100

FG2-80/160

50

FG2-100/160

FG2-50/125

200

H feet

FG2

FG2

FG2-50/160

20

10 100

00

FG2-40/160

FG2-80/200

0/2

FG2-32/160

0

30

FG2-65/200

/20

FG2-32/200

-40

40

FG2-32/200H

1000

2000

50

Flow rate Q 4

3000

100

4000 5000

200

300

PERFORMANCE DATA MODEL

FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2

US g.p.m.

FG2-50/250

80

Head H (metres) 4

1600

pump

32/160 C 32/160 B 32/160 A 32/200 C 32/200 B 32/200 A 32/200 BH 32/200 AH 40/160 C 40/160 B 40/160 A 40/200 B 40/200 A 40/250 C 40/250 B 40/250 A 50/125 C 50/125 B 50/125 A 50/160 C 50/160 B 50/160 A 50/200 C 50/200 B 50/200 A 50/200 AR 50/250 D 50/250 C 50/250 B 50/250 A 50/250 AR

400

m3/h

HS= 0 m

MOTOR PAIRING kW HP 1.5 2.2 3 4 5.5 7.5 3 4 2.2 3 4 5.5 7.5 9.2 11 15 2.2 3 4 4 5.5 7.5 11 15 18.5 22 9.2 11 15 18.5 22

l/min

2 3 4 5.5 7.5 10 4 5.5 3 4 5.5 7.5 10 12.5 15 20 3 4 5.5 5.5 7.5 10 15 20 25 30 12.5 15 20 25 30

PERFORMANCE

Q m³/h

H metres

6 ÷ 21 6 ÷ 24 6 ÷ 27 6 ÷ 27 6 ÷ 30 6 ÷ 30 6 ÷ 18 6 ÷ 19.2 6 ÷ 36 6 ÷ 36 6 ÷ 42 6 ÷ 42 6 ÷ 42 6 ÷ 42 6 ÷ 42 6 ÷ 42 18 ÷ 72 18 ÷ 72 18 ÷ 72 18 ÷ 60 18 ÷ 66 18 ÷ 66 24 ÷ 102 24 ÷ 102 24 ÷ 108 24 ÷ 108 18 ÷ 54 18 ÷ 54 18 ÷ 60 18 ÷ 60 18 ÷ 60

24 ÷ 14 30 ÷ 17 37 ÷ 24 44 ÷ 31.5 51 ÷ 36 57 ÷ 44 45 ÷ 37 55 ÷ 44 27 ÷ 14 32 ÷ 20 38 ÷ 20 47 ÷ 28 55 ÷ 41 64 ÷ 47 71 ÷ 55 88 ÷ 72 17.5 ÷ 6 20.7 ÷ 9 23.5 ÷ 13 27 ÷ 16 32 ÷ 21 37 ÷ 27 44 ÷ 30 52 ÷ 38 61 ÷ 45 69 ÷ 53 51 ÷ 32 59 ÷ 42 72 ÷ 59 85 ÷ 73 95 ÷ 83

MODEL pump FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2  FG2

65/125 C 65/125 B 65/125 A 65/160 C 65/160 B 65/160 A 65/200 B 65/200 A 65/200 AR 65/250 C 65/250 B 65/250 A 80/160 D 80/160 C 80/160 B 80/160 A 80/200 B 80/200 A 80/250 B 80/250 A 100/160 C 100/160 B 100/160 A 100/200 C 100/200 B 100/200 A 100/250 B 100/250 A

MOTOR PAIRING kW HP 4 5.5 7.5 9.2 11 15 15 18.5 22 30 37 45

11

15 18.5 22 30 37 45 55 15 18.5 22 30 37 45 55 75

5.5 7.5 10 12.5 15 20 20 25 30 40 50 60 15 20 25 30 40 50 60 75 20 25 30 40 50 60 75 100

PERFORMANCE Q m³/h

H metres

36 ÷ 108 36 ÷ 108 36 ÷ 132 36 ÷ 132 36 ÷ 144 36 ÷ 144 12 ÷ 144 12 ÷ 156 12 ÷ 156 24 ÷ 141 24 ÷ 150 24 ÷ 156 30 ÷ 240 30 ÷ 240 30 ÷ 240 30 ÷ 240 30 ÷ 219 30 ÷ 234 36 ÷ 216 36 ÷ 234 60 ÷ 300 60 ÷ 330 60 ÷ 360 48 ÷ 279 48 ÷ 294 48 ÷ 315 48 ÷ 309 48 ÷ 345

16 ÷ 11 18 ÷ 13 23 ÷ 18 32 ÷ 22 36.5 ÷ 23 40.5 ÷ 28 44 ÷ 30.5 50 ÷ 36.5 57 ÷ 42 76 ÷ 53 87 ÷ 62 94.5 ÷ 68 25 ÷ 10 30 ÷ 15 35 ÷ 20 40 ÷ 25 56 ÷ 34.5 62 ÷ 40 77 ÷ 54 88.5 ÷ 60 28 ÷ 12 32 ÷ 13 35 ÷ 15 51 ÷ 28 57 ÷ 33 63 ÷ 38 75 ÷ 48 89 ÷ 58

165


FG2

n= 2900 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG2 32/160

FG2  32/200 60

40

FG32/200A

FG32/160A 51

55

57

58

FG32/160B

η = 62% 60

FG32/160C

58

Ø 169

57

20

55

50

52 53

FG32/200B

50

60

H (m)

H (m)

30

45

55

45

54 η = 55% 54

FG32/200C

Ø 209

40 Ø 196

35

51

54

Ø 155

10

3

6

9

12

15

18

21

24

27

3

25

30

Ø 169

P2 (kW)

P2 (kW)

Ø 155

A

1.5 3

B C

Ø 143

6

9

12

15

18

21

24

27

18

24

30

36

NPSH (m)

Ø 169

4 2 3

6

9

12

15

18

Q (m³/h)

21

Ø 196

5

Ø 184

4

24

2

30

6

NPSH (m)

12

Ø 209

A

3

27

B C

0

6

12

18

24

30

8

36

Ø 209

4 0

30

FG2  32/200H

0

6

12

18

24

Q (m³/h)

30

36

FG2  40/160

60

50

55 FG32/200AH

40

43

45

50

48 50

40

51.5

FG40/160A

η = 53.5%

FG32/200BH

45

30

Ø 205

40 Ø 192

35

55

FG40/160B

H (m)

H (m)

6

6

2

0

0

7

2.5

1

Ø 184

30

Ø 143

60 62

64

FG40/160C

η = 65% 64

62

65

60 Ø 169

20

Ø 157 Ø 148

30

10

25 3

6

9

12

15

18

4.5

3

AH

2.5

BH

2

NPSH (m)

3

6

9

12

15

18

8

Ø 205

3

6

9

12

Q (m³/h)

15

18

6

12

18

24

30

36

42

21

48

Ø 169 Ø 157

3

Ø 148

A

2 1

21

4 0

166

P2 (kW)

P2 (kW)

Ø 192

3.5

0

4

Ø 205

4

1.5

0

21

NPSH (m)

20

B C

0

6

12

18

24

30

36

8

42

48

Ø 169

4 0

0

6

12

18

24

Q (m³/h)

30

36

42

48


FG2

n= 2900 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG2  40/200

FG2  40/250 100

60 FG40/200A

55 57

FG40/250A

90

59 63

FG40/200B

η = 64% 63 Ø 205

40

40

44

80

H (m)

H (m)

50

50

59

46

48

FG40/250B

70

50 η = 51% Ø 260

FG40/250C

60

57 55

30

54

Ø 188

20

0

4

8

12

16

20

24

28

32

36

40

8

44

30

48

4

8

12

P2 (kW)

Ø 188

5 4

A

3

B

0

4

8

12

16

20

24

28

32

36

40

44

28

32

36

40

44

4

Ø 205

0

4

Ø 233

10

Ø 223

A

8

8

12

16

20

24

Q (m³/h)

28

32

36

40

44

4

48

8

48

B C

4

8

12

25

35

0

4

8

12

70

73

68

70

10

63

36

32

36

40

44

48

28

32

36

40

44

48

67

42

48

54

60

70

72

78

72

78

72

78

η = 71% 70

66

72

67

71

25

Ø 171

64

Ø 161

62 Ø 152

15 10 12 7.5

78

Ø 145

18

24

30

36

42

48

54

60

66 Ø 171

6.5

3.5

2.5

A

2

B

P2 (kW)

Ø 138

3

Ø 126

C

18

24

30

36

42

48

54

60

66

72

18

24

30

36

42

48

Q (m³/h)

54

60

66

72

4.5

2.5 12

78

NPSH (m)

Ø 145

4

5.5

3.5

8

0 12

62 64

20

Ø 126

5

1.5 12

24

Q (m³/h)

Ø 145 Ø 138

30

20

FG50/160C

70

24

28

30

η = 70%

H (m)

FG50/125C

18

16

FG50/160B

68

15

0 12 4

24

Ø 260

63

FG50/125B

20

FG2  50/160 40

FG50/125A

16

4 0

48

0

8

30

20

H (m)

24

12

FG50/160A

P2 (kW)

20

Ø 260

6

FG2  50/125

NPSH (m)

16

14

NPSH (m)

P2 (kW) NPSH (m)

0

16

Ø 205

6

0

Ø 223

40

7

2

Ø 233

50

78

Ø 161 Ø 152

A B C

18

24

30

36

42

48

54

60

66

8 4 0 12

Ø 171

18

24

30

36

42

48

Q (m³/h)

54

60

66

167


FG2

n= 2900 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG2  50/200

FG2  50/250 100

75 FG50/200AR

65

62

65 67

90

68

FG50/200A

70

69

FG50/200B

Ø 224

FG50/200C

H (m)

H (m)

45

67

54 57

59

η = 61% Ø 261

36

48

60

72

84

96

FG50/250B

Ø 248

FG50/250C

Ø 235

FG50/250D 55 Ø 213

50

30

Ø 185

24

52

FG50/250A

40

Ø 200

35

60 50

Ø 215

68

25 12 25

50

80 η = 70%

55

FG50/250AR

108

Ø 204

20 12 25

120

18

24

30

36

42

48

54

60 Ø 261

Ø 224

5 12

Ø 185

AR A B C

24

36

48

60

72

84

96

108

4 24

36

48

60

72

Q (m³/h)

84

96

108

5 12

120

Ø 224

0 12

15 10

8

NPSH (m)

P2 (kW)

Ø 200

15 10

20

Ø 215

NPSH (m)

P2 (kW)

20

FG2 65/125

AR A B C D

Ø 213 Ø 204

18

24

30

36

42

48

54

60

8

66

Ø 261

4 18

24

30

36

42

48

Q (m³/h)

54

60

66

FG2  65/160 50

25 FG65/125A

70

73

75 80

40

η = 81%

20 FG65/125B

80

H (m)

H (m)

Ø 248 Ø 235

0 12

120

66

Ø 137

FG65/125C

15

FG65/160A

72

78

FG65/160B

80

η = 81% 80

FG65/160C

30

79 Ø 172 Ø 163

75

Ø 156

20

73

Ø 125

10 24 9

Ø 116

36

48

60

72

84

96

108

120

132

144

10 24 16

156

Ø 125

NPSH (m)

3 24

A B C

36

48

60

72

84

96

108

120

132

144

4 48

60

72

84

96

Q (m³/h)

108

120

132

4 24

156

Ø 137

36

10 7

Ø 116

8

0 24

168

P2 (kW)

7 5

48

60

72

84

96

108

120

132

144

156

Ø 172

13

NPSH (m)

P2 (kW)

Ø 137

36

144

156

Ø 163 Ø 156

A B C

36

48

60

72

84

96

108

120

132

8

144

156

Ø 172

4 0 24

36

48

60

72

84

96

Q (m³/h)

108

120

132

144

156


FG2

n= 2900 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG2  65/200

100

FG65/200AR

60

55

70

75 80

FG65/200A

50

H (m)

Ø 210

40

Ø 204

35 30

0

12

24

36

48

60

72

84

40

96 108 120 132 144 156 168

Ø 232

0

24

48

72

96

120

144

168

P2 (kW)

15

Ø 191

AR A B

0

30

Ø 232

20

A B C

10

12

24

36

48

60

72

84

Ø 210

4 12

24

36

48

60

72

84

0

96 108 120 132 144 156 168

8

0

Ø 258 Ø 248

40

NPSH (m)

P2 (kW)

Ø 204

10

NPSH (m)

Ø 258 Ø 248

50 Ø 210

0

24

48

72

96

120

144

8

168 Ø 258

4 0

96 108 120 132 144 156 168

Q (m³/h)

FG2  80/160

0

24

48

72

96

120

Q (m³/h)

144

168

FG2  80/200

45

70 FG80/160A

35

FG80/160B

70

76 81

FG80/200A

η = 84%

FG80/160C

FG80/200B

60

68 70 72

75 79

81 76

FG80/160D

25

60 78 76

20

Ø 175

70

15

η = 82%

50

H (m)

40

30

H (m)

70

70

50

20

0

72

FG65/250C

60

25

5

72

Ø 191

25 20

70

η = 73%

80

η = 82% 81

65

FG65/250B

81

45 FG65/200B

58

FG65/250A

90

H (m)

60

FG2  65/250

Ø 169

79 75 72

40

Ø 215

Ø 160

10

Ø 206

30

Ø 148

5 0

0

30

60

90

120

150

180

210

240

20

270

P2 (kW)

A B C D

0

30

Ø 148

150

200

250

300

60

90

120

150

180

210

8

240

4 30

60

90

120

150

Q (m³/h)

180

210

240

20

0

270

Ø 175

0

Ø 206

A B

10

NPSH (m)

P2 (kW)

Ø 160

10

NPSH (m)

100

30

Ø 169

15

0

50

Ø 215

Ø 175

20

5

0

40

25

270

0

50

100

150

200

8

250

300

Ø 215

4 0

0

50

100

150

Q (m³/h)

200

250

300

169


FG2

n= 2900 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG2  80/250

FG2  100/160 40

76

FG80/250B

30

η = 77% 75 71 69

60

Ø 253

50

0

50

100

150

200

250

P2 (kW)

P2 (kW)

30

A B

20

0

50

100

150

200

250

NPSH (m)

NPSH (m)

Ø 253

4 0

50

100

150

200

Q (m³/h)

250

FG100/200A

60

60

75

79

FG100/200B

80.5

80.5 79

H (m)

H (m)

15

B C

75

79

Ø 220

71

30

180

240

300

360

Ø 210

Ø1 172-Ø2 124

100

60

120

180

240

300

360

8

Ø1 172-Ø2 156

4 0

60

120

180

240

300

Q (m³/h)

360

150

200

FG100/250A

250

65

72 75

300

η = 80% 78

70 η = 79.5%

75 71

60

30

350 Ø 220

40

Ø 256 Ø 236

0

50

100

150

200

250

300

350

P2 (kW)

Ø 201

A B C

6

Ø 236

4 A

2

10 50

100

150

200

250

300

8

NPSH (m)

4 50

100

150

200

Q (m³/h)

250

300

0

350 Ø 220

0

400

Ø 256

8

Ø 210

0

420

78

FG100/250B

10

20

420

40

50

30

420

Ø1 172-Ø2 142

50

Ø 201

50

0

80

35

P2 (kW)

120

Ø1 172-Ø2 156

90 80.5 η = 81%

40

NPSH (m)

60

100 71

45

170

0

FG2  100/250

50 FG100/200C

0

65

A

0

300

FG2 100/200

0

69

Ø1 172-Ø2 156 Ø1 172-Ø2 142 Ø1 172-Ø2 124

20

5

300

8

0

70

10

10

25

71

20

25

Ø 238

40

55

η = 75%

25

5

300

Ø 253

50

65

71

10

60

0

70

FG100/160C

15

Ø 238

40

0

65 69

FG100/160B

75

70

30

FG100/160A Ø1

35

H (m)

H (m)

80

70

Ø2

FG80/250A

90

Ø1

100

350

B

0

50

100

150

200

250

300

10

350

400

Ø 256

5 0

0

50

100

150

200

Q (m³/h)

250

300

350

400


FG4

n= 1450 1/min

PERFORMANCE RANGE 20

HS= 0 m 30

50

20

30

100 50

200

500

100

US g.p.m.

200

500

Imp. g.p.m. 80

FG4-40/250

20

FG4-50/250

FG4 - 10 0/2 50

FG4-65/250 FG4-50/200

9 8

FG4-50/160

FG4-32/160

7

FG4-65/200 FG4-80/200

FG4-65/160

FG4-80/160

H feet

-10 0/2 00

FG4-32/200

50

30

FG4

FG4-32/200H

10

FG4 -40 /20 0

Head H (metres) 4

FG4-80/250

25 20

6

60

5

3

4

5

6

200 7

8

FG4-65/125

400

9 10

-10

0/1 100

50

FG4-50/125

600

FG4

FG4-40/160

4 3

15

800 1000

30

40

Flow rate Q 4

2000

50

3000

200 m 3/h

100

PERFORMANCE DATA MODEL

FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4

pump

32/160 C 32/160 B 32/160 A 32/200 C 32/200 B 32/200 A 32/200 BH 32/200 AH 40/160 C 40/160 B 40/160 A 40/200 B 40/200 A 40/250 C 40/250 B 40/250 A 50/125 C 50/125 B 50/125 A 50/160 C 50/160 B 50/160 A 50/200 C 50/200 B 50/200 A 50/200 AR 50/250 D 50/250 C 50/250 B 50/250 A 50/250 AR

HS= 0 m

MOTOR PAIRING kW HP 0.25 0.37 0.37 0.55 0.75 1.1 0.55 0.55 0.37 0.37 0.55 0.75 1.1 1.1 1.5 2.2 0.37 0.55 0.55 0.55 0.75 1.1 1.5 2.2 2.2 3 1.1 1.5 2.2 2.2 3

10

l/min

0.33 0.5 0.5 0.75 1 1.5 0.75 0.75 0.5 0.5 0.75 1 1.5 1.5 2 3 0.5 0.75 0.75 0.75 1 1.5 2 3 3 4 1.5 2 3 3 4

PERFORMANCE

Q m³/h

H metres

3 ÷ 10.5 3 ÷ 12 3 ÷ 13.5 3 ÷ 13.5 3 ÷ 15 3 ÷ 15 3 ÷ 9 3 ÷ 9.6 3 ÷ 18 3 ÷ 18 3 ÷ 21 3 ÷ 21 3 ÷ 21 3 ÷ 21 3 ÷ 21 3 ÷ 21 9 ÷ 36 9 ÷ 36 9 ÷ 36 9 ÷ 30 9 ÷ 33 9 ÷ 33 12 ÷ 51 12 ÷ 51 12 ÷ 54 12 ÷ 54 9 ÷ 27 9 ÷ 27 9 ÷ 30 9 ÷ 30 9 ÷ 30

6 ÷ 3.5 7.5 ÷ 4 9 ÷ 6 11 ÷ 8 12.5 ÷ 9 14 ÷ 11 11 ÷ 9 13.5 ÷ 11 6.5 ÷ 3.5 8 ÷ 5 9.5 ÷ 5 11.5 ÷ 7 13.5 ÷ 10 16 ÷ 11.5 17.5 ÷ 13.5 22 ÷ 18 4 ÷ 1.5 5 ÷ 2 6 ÷ 3 7 ÷ 4 8 ÷ 5 9 ÷ 7 11 ÷ 7.5 13 ÷ 9.5 15 ÷ 11 17 ÷ 13 12.5 ÷ 8 14.5 ÷ 10.5 18 ÷ 14.5 21 ÷ 18 24 ÷ 21

MODEL

FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4  FG4

pump

MOTOR PAIRING kW HP

65/125 C 65/125 B 65/125 A 65/160 C 65/160 B 65/160 A 65/200 B 65/200 A 65/200 AR 65/250 C 65/250 B 65/250 A 80/160 D 80/160 C 80/160 B 80/160 A 80/200 B 80/200 A 80/250 B 80/250 A 100/160 C 100/160 B 100/160 A 100/200 C 100/200 B 100/200 A 100/250 B 100/250 A

0.55 0.75 1.1 1.1 1.5 2.2 2.2 2.2 3 3 4 5.5 1.5 2.2 2.2 3 4 5.5 5.5 7.5 2.2 3 3 4 5.5 5.5 7.5 9.2

0.75 1 1.5 1.5 2 3 3 3 4 4 5.5 7.5 2 3 3 4 5.5 7.5 7.5 10 3 4 4 5.5 7.5 7.5 10 12.5

PERFORMANCE

Q m³/h

H metres

18 ÷ 54 18 ÷ 60 18 ÷ 66 18 ÷ 66 18 ÷ 72 18 ÷ 72 6 ÷ 72 6 ÷ 78 6 ÷ 78 12 ÷ 70.5 12 ÷ 75 12 ÷ 78 15 ÷ 120 15 ÷ 120 15 ÷ 120 15 ÷ 120 15 ÷ 109.5 15 ÷ 117 18 ÷ 108 18 ÷ 117 30 ÷ 150 30 ÷ 165 30 ÷ 180 24 ÷ 139.5 24 ÷ 147 24 ÷ 157.5 24 ÷ 154.5 24 ÷ 172.5

4 ÷ 2.5 4.5 ÷ 3 5.5 ÷ 4.5 8 ÷ 5.5 9 ÷ 5.5 10 ÷ 7 11 ÷ 8 12.5 ÷ 9 14.3 ÷ 10.5 19 ÷ 13 21.5 ÷ 15.5 23.5 ÷ 17 6 ÷ 2.5 7.5 ÷ 3.5 8.5 ÷ 5 10 ÷ 6 14 ÷ 8.5 15.5 ÷ 10 19 ÷ 13.5 22 ÷ 15 7 ÷ 3 8 ÷ 3 8.5 ÷ 3.5 12.5 ÷ 7 14 ÷ 8 15.5 ÷ 9.5 18.5 ÷ 12 22 ÷ 14.5

171


FG4

n= 1450 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG4 32/160

FG4  32/200

10

20 FG32/160A

8

48

52

55

58

FG32/160B

7

15 FG32/200A

η = 60.5% 58 59

FG32/160C

6

H (m)

42

Ø 169

52

5

48 Ø 155 48

4

35

40

FG32/200B

H (m)

9

45

48

η = 51% 50

FG32/200C

Ø 209

10

Ø 196 Ø 184

Ø 143

3

5

2 1 0

0

5

10

0

15

0.5

Ø 155

A B C

0.2 0.1

Ø 143

0

5

10

15

Ø 169

4 2 0

5

10

Q (m³/h)

Ø 184

A B C

0

5

10

15

20

8 Ø 209

4 0

15

FG4  32/200H

0

5

10

15

Q (m³/h)

20

FG4  40/160 10

15 38

FG32/200AH

20

Ø 209

0.5

0

15

6

NPSH (m)

10

Ø 196

P2 (kW)

0.3

0

5

Ø 169

NPSH (m)

P2 (kW)

0.4

0

0

1

42 45

FG40/160A

40

9

48

50

FG32/200BH

η = 51%

10

60

62

η = 63%

FG40/160C

7

62

6

H (m)

Ø 192

H (m)

56

FG40/160B

8

Ø 205

50

5

5

60

Ø 157

Ø 169

4 Ø 148

3 2 1

0

0

1

2

3

4

5

6

7

8

9

0

10

0.6 0.4

Ø 192

AH BH

1

2

3

4

5

6

7

8

9

15

20

25

Ø 205

4 0

1

2

3

4

5

Q (m³/h)

6

7

8

9

10

Ø 169

Ø 157

A B C 0

10

NPSH (m)

NPSH (m)

172

0

8

0

10

0.5

0.2 0

5

Ø 205

P2 (kW)

P2 (kW)

0

1

0.8

0

Ø 148

5

10

15

20

8

25 Ø 169

4 0

0

5

10

Q (m³/h)

15

20

25


FG4

n= 1450 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG4  40/200

25

FG40/200A

40

42

50

FG40/250A

53 56

FG40/200B

59

20

η = 61% 59

10

56

35

40 42

45

47

η = 49% Ø 260

15

54

H (m)

30

FG40/250B FG40/250C

Ø 205

H (m)

15

FG4  40/250

Ø 188

5

Ø 233 Ø 223

10 5

0

0

5

10

15

20

1

0

25

0

5

10

15

20

25

3

Ø 205

P2 (kW)

0.5

0

NPSH (m)

A B

0

5

10

15

20

8 4 0

Ø 205

0

5

10

Q (m³/h)

15

20

FG4  50/125 54

FG50/125A

60

65

FG50/125B FG50/125C

10

15

20

25 Ø 260

4 0

5

4

68.5

10

Q (m³/h)

15

20

Ø 145

70

2

FG50/160A

8

FG50/160B

1

50

55

60

65

η = 69% 68 69

FG50/160C

25

62

5 3

Ø 126

2

Ø 161

55

4

Ø 138

65 Ø 171

6

65

71

3

9 7

η = 68.5%

H (m)

5

H (m)

5

10

6

Ø 152

1

0

5

10

15

20

25

30

35

0

40

0

5

10

15

20

25

30

1

0.6 Ø 145 Ø 138

0.4

A B C

0.2

Ø 126

35

40

Ø 171

0.8

P2 (kW)

P2 (kW)

0

8

FG4  50/160

7

0

Ø 233 Ø 223

A B C

1

0

25

Ø 260

2

0

25

NPSH (m)

P2 (kW)

Ø 188

Ø 161

0.6

Ø 152

A B C

0.4 0.2

0

5

10

15

20

25

30

35

8 Ø 145

4 0

0

5

10

15

20

Q (m³/h)

25

30

35

0

40

NPSH (m)

NPSH (m)

0

40

0

5

10

15

20

25

30

35

40

8 Ø 171

4 0

0

5

10

15

20

Q (m³/h)

25

30

35

40

173


FG4

n= 1450 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG4  50/200

FG4  50/250 25

20 50

FG50/200AR

60

64

66

FG50/200A

66

FG50/200B FG50/200C

η = 67.5% 66.5 Ø 224

10

Ø 200 Ø 185

50 52

55

η = 58% Ø 261

FG50/250B

Ø 248

FG50/250C

Ø 235

FG50/250D Ø 213

10 50

5

0

45

FG50/250A

15

Ø 215

40

FG50/250AR

20

H (m)

15

H (m)

55

Ø 204

5

0

10

20

30

40

50

0

60

3

0

5

10

15

20

25

30

3

Ø 224

Ø 261 Ø 248

0

P2 (kW)

1 0

NPSH (m)

Ø 200 Ø 185

AR A B C

10

20

30

40

50

8

Ø 224

4 0

0

10

20

30

40

Q (m³/h)

50

Ø 235

AR A B C D

1

0

5

Ø 213 Ø 204

10

15

20

25

30

8

35

Ø 261

4 0

60

FG4 65/125

2

0

60

NPSH (m)

P2 (kW)

Ø 215

2

35

0

5

10

15

20

25

Q (m³/h)

30

35

FG4  65/160

8

12

7

5

H (m)

52

FG65/125A

60

65

70

74

78

η = 79.5%

4

Ø 137

70

70

3

65

72

FG65/160B

78

FG65/125B FG65/125C

54 60

FG65/160A

10

H (m)

6

76 η = 79%

FG65/160C

8

76

Ø 125

Ø 172

Ø 116

6

2

Ø 156

1 0

0

10

20

30

40

50

60

4

70

0

10

20

30

40

50

60

70

2

2

Ø 163

80 Ø 172

A B C

NPSH (m)

0

10

20

30

40

50

60

Ø 137

4 0

10

20

30

40

Q (m³/h)

50

60

70

Ø 156

A B C

1

0

70

8

0

174

0

Ø 116

Ø 125

P2 (kW)

1

NPSH (m)

P2 (kW)

Ø 163

Ø 137

0

10

20

30

40

50

60

70

8

80 Ø 172

4 0

0

10

20

30

40

Q (m³/h)

50

60

70

80


FG4

n= 1450 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG4  65/200

25

FG65/200AR

60

65

70

75

FG65/200A

10

78

79 η = 80.1% 79

H (m)

FG65/200B

Ø 191

20

30

40

50

60

70

2

NPSH (m)

0

20

30

40

50

60

10

20

30

40

Q (m³/h)

50

FG80/160A

50

60

70

80

Ø 232

3

A B C

2 0

80

70

0

10

20

30

40

50

60

70

80

8

Ø 258

4 0

80

78

0

10

20

30

40

50

Q (m³/h)

60

Ø 175

6

Ø 169

4

70

80

30

40

50

60

70

80

90

3

20

30

40

50

60

70

80

90

8

20

30

40

50

60

70

80

90

100 110 120 130 Ø 215 Ø 206

3 A B

2

4 20

30

40

50

60

70

Q (m³/h)

80

90

0

100 110 120 130 Ø 175

10

10

1

12

0

0

4

100 110 120 130

NPSH (m)

10

Ø 148

Ø 215

5

P2 (kW)

Ø 169 Ø 160

A B C D

0

η = 78.5% 75

10

0

100 110 120 130 Ø 175

1

75

5

Ø 148

2

2

70

Ø 206

Ø 160

20

60

78

FG80/160D

10

50

FG80/200B

η = 80%

FG80/160C

0

FG80/200A

15

H (m)

8

H (m)

60

FG4  80/200 70 73

FG80/160B

P2 (kW)

50

20

10

NPSH (m)

40

4

70

60

30

Ø 204

Ø 210

0

20

Ø 258

12

0

10

Ø 248

FG4  80/160

0

0

5

4

0

10

1

8

0

Ø 258 Ø 248

Ø 210

AR A B

10

70

6

Ø 191

0

η = 71.5%

Ø 232

0

80

NPSH (m)

P2 (kW)

3

1

70

5

P2 (kW)

10

65

15

Ø 204

5

0

58

20 FG65/250C

Ø 210

0

50

FG65/250A FG65/250B

H (m)

15

FG4  65/250

0

10

20

30

40

50

60

70

80

90

100 110 120 130

12 Ø 215

8 4 0

0

10

20

30

40

50

60

70

Q (m³/h)

80

90

100 110 120 130

175


FG4

n= 1450 1/min

CHARACTERISTIC CURVES

HS= 0 m

FG4  80/250

FG4  100/160 10

9 FG100/160A 8 FG100/160B

75

20 FG80/250B

η = 76% 75

H (m)

60 70

7 FG100/160C

72

15

50

Ø 253 Ø 238

72 η = 75%

6

10

72

5 4

70

Ø1 172-Ø2 156 Ø1 172-Ø2 142 Ø1 172-Ø2 124

3 2

5

Ø1

70

Ø2

FG80/250A

60

H (m)

50

Ø1

25

1

0

0

10

20

30

40

50

60

70

80

90

0

100 110 120 130

10 Ø 253 Ø 238

4

A B

2

NPSH (m)

40

0

10

20

30

40

50

60

70

80

90

80

100

120

140

160

180

200

12 8

Ø 253

4 0

10

Ø1 172-Ø2 156

A B C

2

20

30

40

50

60

70

Q (m³/h)

80

90

0

100 110 120 130

Ø1 172-Ø2 142 Ø1 172-Ø2 124

0

20

40

60

80

100

120

140

160

180

12

200

Ø1 172-Ø2 156

8 4 0

100 110 120 130

FG4 100/200

0

20

40

60

80

100

Q (m³/h)

120

140

160

180

200

FG4  100/250

20

25 FG100/250A

15 FG100/200B

55

65

72

75

FG100/200C

78

η = 79% 78

10

55

65

70

20 FG100/250B

70 Ø 220 Ø 210

75

77 η = 78% 77 79

15

75

H (m)

FG100/200A

H (m)

60

1

NPSH (m)

P2 (kW)

6

0

20

3

P2 (kW)

8

0

0

4

75

72 Ø 256 Ø 236

10

Ø 201

5

0

5 0

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180

2

NPSH (m)

0

P2 (kW)

Ø 210 Ø 201

A B C

4

0

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180

8

Ø 220

4 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180

Q (m³/h)

176

Ø 236

6 A B

2

12

0

Ø 256

8

Ø 220

NPSH (m)

P2 (kW)

6 4

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180

10

8

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180

12

Ø 256

8 4 0

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180

Q (m³/h)


DIMENSIONS AND WEIGHT a

f

x

DN2

d

DN1

u

d

h2

l

SHAFT DIMENSIONS mm d u t 24 k6 8 27 32 k6 10 35

w m2 m1

DN FLANGES 32 40 50 65 80 100 125

MODEL

DN2

50

32

FG 32/200H

f

80

FG 40/160 FG 40/200

65

40

FG 40/250 FG 50/125 FG 50/160 FG 50/200

360 65

50 100

FG 50/250 FG 65/125 FG 65/160 FG 65/200

80

65

h1

h2

b

m1

132

160

50

100

160

180

55

160

180

55

132

160

50

160

180

55

180

225

65

132

160

50

160

180

55

160

200

50

180

225

65

160

180

65

160

200

65

180

225

65

FG 65/250

470

200

250

80

FG 80/160

360

180

225

65

180

250

65

200

280

80

200

280

80

200

280

80

225

280

80

FG 80/200

100

80 125

FG 80/250 FG 100/160 FG 100/200 FG 100/250

470 360

125

K mm 100 110 125 145 160 180 210

S1

b S2 110 n2 n1

HOLES N° Ø (mm) FLANGES

4 18 DN K D

8

kg

DIMENSIONS mm a

FG 32/160 FG 32/200

D mm 140 150 165 185 200 220 250

PORTS DN1

h1

t

100 140

470

95

m2

100

125

70

s1

s2

w

x

d

l

240

35

190

35 35

95

70

95

160

120

125

95

160

n2

32

100 125

n1

120

265

212

320

250

240

190

265

212

320

250

280

212

320

250

360

280

320

250

345

280

400

315

360

280

400

315

38

14

260

100

58 24

50

30 35 45 50

14

42 45 50

18 14

340

32

80

71

260

24

50

48

32

80

260

24

50

340

32

80

340

18

140

65 79 55 75 88

177


NK Multi-stage submersible pumps

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

As a result of their high efficiency and reliability they are suitable for use with clean water in domestic, civil and agricultural applications such as the distribution of water in combination with pressure sets, for the irrigation of gardens and allotments and for pressure boosting, etc.

•• Flow rate up to 120 l/min (7.2 m³/h) •• Head up to 105 m •• Maximum liquid temperature +40 °C •• Maximum sand content 50 g/m³ •• 20 m maximum immersion depth •• Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS ➠ Complete with 20 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

178

OPTIONALS AVAILABLE ON REQUEST

•• Pumps fitted with power cables of other lengths •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

110

5

0

15

5

20

10

25

15

20

30

US g.p.m.

25

Imp g.p.m.

feet 350

NK4/5

100

300

90

NK2/5 NK2/4

80

Head H (metres) 4

10

50 Hz  n= 2900 1/min

250

NK4/4

70

NK4/3

60

200

NK2/3

50

NK4/2

NK2/2

40

150

NK2/1

NK4/1 100

30 20

50

10 0

0

10

20

0

30

1

40

50

2

60

3

70

80

4

90

100

5

110

6

120

l/min

0

m³/h

7

Flow rate Q 4 VERSION WITHOUT FLOAT SWITCH MODEL Single-phase NKm 2/1 NKm 2/2 NKm 2/3 NKm 2/4 NKm 2/5 NKm 4/1 NKm 4/2 NKm 4/3 NKm 4/4 NKm 4/5

Three-phase – – NK 2/3 NK 2/4 NK 2/5 – NK 4/2 NK 4/3 NK 4/4 NK 4/5

POWER kW 0.45 0.55 0.75 1.1 1.5 0.55 0.75 1.1 1.5 2.2

HP 0.6 0.75 1 1.5 2 0.75 1 1.5 2 3

Q

m³/h

0

0.6

1.2

1.8

l/min

0

10

20

35 46 58 80 87 – – – – –

33 44 55 75 83 37 48 65 72 101

36 48 60 84 90 H metres 40 50 67 75 105

2.4

3.0

3.6

4.2

4.8

5.4

6.0

6.6

7.2

30

40

50

60

70

80

90

100

110

120

31 41.5 51 70 78 36 46 62.5 69 98

28.5 39 47 65 73 34.5 44 60 66 94

26 35 42 59 66 32.5 41 56.5 64 90

23 30 36 51 58 30 38 52 60 86

19 25 30 42.5 48 28 35 48 57 80

15 19 23 34 38 25 32 44 53 75

21.5 28 38 48 67

18.5 24 32 43 60

14.5 19 25 38 52

10 14 18 32 44

2.4

3.0

3.6

4.2

4.8

5.4

6.0

6.6

7.2

“GE” VERSION WITH FLOAT SWITCH MODEL Single-phase NKm 2/1 - GE NKm 2/2 - GE NKm 2/3 - GE NKm 2/4 - GE NKm 2/5 - GE NKm 4/1 - GE NKm 4/2 - GE NKm 4/3 - GE NKm 4/4 - GE NKm 4/5 - GE Q = Flow rate H = Total manometric head

POWER kW 0.45 0.55 0.75 1.1 1.5 0.55 0.75 1.1 1.5 2.2

HP 0.6 0.75 1 1.5 2 0.75 1 1.5 2 3

Q

m³/h

0

0.6

1.2

1.8

l/min

0

10

20

30

40

50

60

70

80

90

100

110

120

35 46 58 80 87 – – – – –

33 44 55 75 83 37 48 65 72 101

31 41.5 51 70 78 36 46 62.5 69 98

28.5 39 47 65 73 34.5 44 60 66 94

26 35 42 59 66 32.5 41 56.5 64 90

23 30 36 51 58 30 38 52 60 86

19 25 30 42.5 48 28 35 48 57 80

15 19 23 34 38 25 32 44 53 75

21.5 28 38 48 67

18.5 24 32 43 60

14.5 19 25 38 52

10 14 18 32 44

36 48 60 84 90 H metres 40 50 67 75 105

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

179


NK (0.45÷1.1 kW) POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

EXTERNAL SLEEVE

Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

MOTOR SLEEVE

Stainless steel AISI 304

4

IMPELLERS AND DIFFUSERS

Noryl GFN2V

5

DIAPHRAGMS

Stainless steel AISI 304, complete with anti-wear ring

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

ST1-16 ST1-15 SIC

Ø 16 mm Ø 15 mm

8

BEARINGS

6303 2RS - C3 / 6203 ZZ - C3

9

CAPACITOR

Position Motor side Pump side

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

NKm 2/1 NKm 2/2 NKm 4/1 NKm 2/3 NKm 4/2 NKm 2/4 NKm 4/3

16 μF 500 VL

30 μF 250 VL

16 μF 500 VL

30 μF 250 VL

20 μF 500 VL

25 μF 500 VL

Materials Stationary ring

Rotational ring

Elastomer

Silicon carbide Silicon carbide

Graphite Graphite

NBR NBR

10 ELECTRIC MOTOR NKm: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. NK: three-phase 400 V - 50 Hz. – Insulation: F class. – Protection: IP X8. 11

POWER CABLE ➠ 20 metre long DRINCABLE® for permanent immersion in drinking water

12

11

8

1

9

3 10

6 8

12

7

FLOAT SWITCH 5 4

2

180


DIMENSIONS AND WEIGHT DN

MODEL

PORT DN

Single-phase Three-phase

DIMENSIONS mm Ø

kg

h

1~

3~

495

13.9

3

NKm 2/2

4

519

14.5

NKm 2/3

NK 2/3

5

573

16.3

15.2

NKm 2/4

NK 2/4

621

18.1

18.0

NKm 4/1

4

519

14.3

NKm 4/2

NK 4/2

5

573

16.2

15.2

NKm 4/3

NK 4/3

7

621

18.1

18.0

1¼”

135

7

h

NKm 2/1

N° STAGES

Ø

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

MODEL 110 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

240 V

415 V

NKm 2/1

4.5 A

4.5 A

9.0 A

NK 2/3

4.5 A

2.6 A

4.5 A

2.6 A

NKm 2/2

5.0 A

5.0 A

10.0 A

NK 2/4

5.2 A

3.0 A

5.2 A

3.0 A

NKm 2/3

6.0 A

6.0 A

NK 4/2

4.5 A

2.6 A

4.5 A

2.6 A

NKm 2/4

7.5 A

7.5 A

NK 4/3

5.2 A

3.0 A

5.2 A

3.0 A

NKm 4/1

5.0 A

5.0 A

10.0 A

NKm 4/2

6.0 A

6.0 A

NKm 4/3

7.5 A

7.5 A

PALLETIZATION MODEL

CONTAINER kg

kg

H (mm)

1~

3~

n° pumps

H (mm)

1~

3~

30

1015

434

60

1890

852

30

1015

452

60

1890

887

25

869

425

400

40

1307

670

626

25

869

469

467

40

1307

740

737

Three-phase

NKm 2/1

NK 2/3 NK 4/2 NK 2/4 NK 4/3

H

0 80

n° pumps

Single-phase NKm 2/2 NKm 4/1 NKm 2/3 NKm 4/2 NKm 2/4 NKm 4/3

GROUPAGE

00

12

181


NK (1.5÷2.2 kW) POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

EXTERNAL SLEEVE

Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

MOTOR SLEEVE

Stainless steel AISI 304

4

IMPELLERS AND DIFFUSERS

Noryl GFN2V

5

DIAPHRAGMS

Stainless steel AISI 304, complete with anti-wear ring

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-19 MG1-18 SIC

Ø 19 mm Ø 18 mm

8

BEARINGS

6304 2RS - C3 / 6203 ZZ - C3

9

CAPACITOR

Position Motor side Pump side

Pump

Capacitance

Single-phase

(230 V or 240 V)

NKm 2/5 NKm 4/4 NKm 4/5

Materials Stationary ring

Rotational ring

Elastomer

Silicon carbide Silicon carbide

Graphite Silicon carbide

NBR NBR

11

35 μF 450 VL 50 μF 450 VL 1

10

ELECTRIC MOTOR NKm: single-phase 230 V - 50 Hz. Windings up to 1.5 kW with built-in thermal overload protector. ➠ The NKm4/5 2.2 kW pump is equipped with an external manual reset overload protector housed in the control box. NK:

three-phase 400 V - 50 Hz.

8 6

3

– Insulation: F class. – Protection: IP X8. 11

10

8

POWER CABLE ➠ 20 metre long DRINCABLE® with removable connector for permanent immersion in drinking water

12

CONTROL BOX (for single-phase versions)

13

FLOAT SWITCH

12 7

5 9

4

2

182

13


DIMENSIONS AND WEIGHT

DN

PORT

Single-phase Three-phase

DN

NKm 2/5

NK 2/5

NKm 4/4

NK 4/4

NKm 4/5

NK 4/5

N° STAGES

DIMENSIONS mm Ø

6 1¼”

5

153

7

kg

h

1~

3~

612

26.7

23.8

582

26.0

24.4

642

30.5

28.0

h

MODEL

Ø

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

240 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

240 V

415 V

NKm 2/5

9.0 A

9.0 A

NK 2/5

6.2 A

3.6 A

6.2 A

3.6 A

NKm 4/4

9.5 A

9.5 A

NK 4/4

6.2 A

3.6 A

6.2 A

3.6 A

NKm 4/5

14.0 A

14.0 A

NK 4/5

8.5 A

4.9 A

8.5 A

4.9 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

H (mm)

1~

3~

n° pumps

NK 2/5

20

1100

551

493

40

2060 1085

969

NKm 4/4

NK 4/4

20

1100

537

505

40

2060 1058

993

NKm 4/5

NK 4/5

20

1100

627

576

40

2060 1237

1136

Three-phase

NKm 2/5

H (mm)

kg

n° pumps

Single-phase

1~

3~ H

0 80

00

12

183


DAVIS® 4” submersible pump with peripheral impellers

➠ Ready to install, stainless steel

monoblock submersible pump. Complete with: – motor with built-in capacitor and thermal overload protector – 20 m long power cable.

PERFORMANCE RANGE

•• Flow rate up to 50 l/min (3.0 m³/h) •• Head up to 75 m

APPLICATION LIMITS

•• Maximum liquid temperature +40 °C •• Maximum immersion depth of 40 m with a sufficiently long power cable

•• Vertical and horizontal installation •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

184

INSTALLATION AND USE Suitable for use with clean water that does not contain abrasive particles and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their compact design and economy, they are suitable for domestic applications such as the distribution of water in combination with small pressure sets and for irrigation, etc.

PATENTS - TRADE MARKS - MODELS

•• Patent n. PCT/IB2009/051491 •• Patent Pending n. PCT/EP2009/059855

OPTIONALS AVAILABLE ON REQUEST

•• 30 m long power cable •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

80

2

4

0

50 Hz  n= 2900 1/min

6

2

8

4

10

6

8

12

US g.p.m.

10

Imp g.p.m. feet 250

70

DAVIS® 200

Head H (metres) 4

60

50 150

40

100

30

20 50

10

0

0 0

5

10

15

0.5

20

25

1

30

35

1.5

40

2

45

50

2.5

3

l/min 0

0 1

m³/h

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

DAVIS®

0.75

1

Q = Flow rate H = Total manometric head

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

3.0

l/min

0

5

10

15

20

25

30

35

40

50

75

68

62

55

49

42

36

29

23

5

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

185


DAVIS® POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

DELIVERY BODY

Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1

2

PUMP BODY BACK-PLATE

Brass, reduces the risk of impeller seizure (patented)

3

IMPELLER

Brass, with peripheral radial vanes

4

MOTOR SLEEVE

Stainless steel AISI 304

5

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

6

TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

AR-14 MG1-14 SIC

Ø 14 mm Ø 14 mm

7

BEARINGS

8

CAPACITOR

Position Motor side Pump side

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Ceramic

Graphite Silicon carbide

NBR NBR

6203 ZZ - C3 / 6203 ZZ - C3

1

Capacitance

9

(230 V or 240 V)

(110 V)

31.5 μF 500 VL

70 μF 250 VL

10 2 3

ELECTRIC MOTOR Submersible PEDROLLO motor, suitable for continuous duty (with dry, rewindable stator).

6 7

DAVISm: single-phase 230 V - 50 Hz Motor with built-in capacitor. Thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8. 10

POWER CABLE

5

4

9

➠ 20 metre long PBS-P cable for AD8 permanent immersion NF C 15-100, ACS guaranteed for contact with drinking water 7

8

Patented

186


DIMENSIONS AND WEIGHT Typical installation DN

h

Safety cable anchorage point

The DAVIS® pump should be installed in boreholes of at least 4” in diameter. The pump should be lowered into the borehole, by means of the delivery pipe, to such a depth (min. 50 cm and at least one metre from the bottom) that it is completely immersed. It is good practice to secure the pump by attaching a stainless steel or nylon cable to the anchorage points present on the delivery body.

Ø

MODEL Single-phase DAVIS® - 230 V DAVIS® - 110 V

PORT

DIMENSIONS mm

DN

Ø

1”

101

h

kg

470

12.6

500

12.8

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

DAVIS®

5.7 A

5.5 A

11.5 A

PALLETIZATION MODEL

GROUPAGE / CONTAINER

Single-phase

n° pumps

H (mm)

kg 1~

DAVIS® - 230 V

60

1590

780

DAVIS® - 110 V

60

1590

792

H

0 80

00

12

187


4BLOCK 4” monoblock submersible pump

➠ Ready to install, stainless steel monoblock submersible pump. Complete with: – motor with built-in capacitor and thermal overload protector – 20 m long power cable.

PERFORMANCE RANGE

•• Flow rate up to 150 l/min (9 m³/h) •• Head up to 128 m

APPLICATION LIMITS

•• Maximum liquid temperature +35 °C •• Maximum sand content 150 g/m³ •• Maximum immersion depth of 60 m with a sufficiently long •• •• ••

power cable Vertical and horizontal installation Starts/hour: 20 at regular intervals Continuous service S1

INSTALLATION AND USE Suitable for pumping clean water from boreholes that contain sand (up to 150 g/m³). As a result of their high efficiency and reliability they are suitable for use in domestic applications such as domestic water supply as part of a pressure supply and for irrigation, etc.

PATENTS - TRADE MARKS - MODELS

•• Patent n° P CT/IB2009/051491 •• Patent Pending n° PCT/EP2009/059855, BO2009A000650

OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

188

•• 30 metre long power cable •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

130

4

8

0

12

4

16

8

50 Hz  n= 2900 1/min

20

12

24

16

28

20

32 24

36 28

40

US g.p.m. Imp g.p.m.

32

feet

4BLOCK 2/20

400

120 110

350 η = 48%

100

300

Head H (metres) 4

90

4BLOCK 2/13

80 250 η = 55%

70

4BLOCK 2/10

η = 48%

200

60 50

η = 48% η = 55%

150 η = 62%

40 η = 55%

4BLOCK 4/14

30

100

η = 62%

4BLOCK 6/9

4BLOCK 4/9

20

η = 62%

4BLOCK 6/6

4BLOCK 4/7

0

50

4BLOCK 6/4

10

0 0

25 1

50 2

75

3

100

4

5

125

6

150

7

8

l/min

9

10

0

m³/h

Flow rate Q 4 MODEL

POWER

Single-phase

kW

HP

4BLOCKm 2/10

0.55

0.75

4BLOCKm 2/13

0.75

1

4BLOCKm 2/20

1.1

1.5

MODEL

POWER

Single-phase

kW

HP

4BLOCKm 4/7

0.55

0.75

4BLOCKm 4/9

0.75

1

4BLOCKm 4/14

1.1

1.5

MODEL

POWER

Single-phase

kW

HP

4BLOCKm 6/4

0.55

0.75

4BLOCKm 6/6

0.75

1

4BLOCKm 6/9

1.1

1.5

Q = Flow rate H = Total manometric head

Q

1.2

1.8

2.4

3.0

3.6

0

10

20

30

40

50

60

66

65

60

54

46

35

20

86

85

79

71

60

45

26

128

125

118

108

91

70

39

m³/h

0

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

l/min

0

20

30

40

50

60

70

80

90

100

46

44

42

40

38

35

31.5

27

23

17

60

56

54.5

52

49

45

40.5

35

29

23

92

88

85

81

76

70

63

54.5

45

35

H metres

Q

0.6

l/min

H metres

Q

0

m³/h

m³/h l/min

H metres

0

1.5

3.0

4.5

6.0

7.5

9.0

0

25

50

75

100

125

150

27

26

24

22

19

15

11

40

38

36

33

29

24

17

61

58

54

50

44

35

26

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

189


4BLOCK POS.COMPONENT

CONSTRUCTION CHARACTERISTICS

1 DELIVERY BODY AND EXTERNAL SLEEVE

Stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1.

2 IMPELLERS

Lexan 141-R

3 DIFFUSERS

Noryl GFN2V

4 STAGE CASING

Stainless steel AISI 304

5 PUMP SHAFT

Stainless steel AISI 304

6 PUMP BEARINGS

Special-technopolymer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing.

1

6

15

2

8

7 DRIVE COUPLING

Stainless steel AISI 316L

3

8 CABLE COVER

Stainless steel AISI 304

4

9 MOTOR SHAFT

Stainless steel EN 10088-3 1.4104 (AISI 431 for single-phase 1.1 kW)

10 MOTOR SLEEVE

Stainless steel AISI 304 7

11 TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

STA-17

Ø 17 mm

Motor side

ST1-16 SIC

Ø 16 mm

Pump side

Position

5

Materials Stationary ring Rotational ring

Silicon carbide Silicon carbide

Elastomer

Graphite

NBR

Silicon carbide

NBR

11

12

12 BEARINGS Pump

Model

4BLOCK – 0.55÷0.75 kW 4BLOCK – 1.1 kW

6203 ZZ - C3 / 6203 ZZ - C3 3203B ZZ - C3 / 6203 ZZ - C3

9

14

13 CAPACITOR Pump

Capacitance

Single-phase

(230 V or 240 V)

4BLOCK – 0.55 kW 4BLOCK – 0.75 kW 4BLOCK – 1.1 kW

20 μF 500 VL 31.5 μF 500 VL 35 μF 500 VL

14 ELECTRIC MOTOR Submersible PEDROLLO motor, suitable for continuous duty (with dry, rewindable stator).

12

13 10

Single-phase 230 V - 50 Hz Motor with built-in capacitor. Thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8. 15 POWER CABLE ➠ 20 metre long PBS-P cable for AD8 permanent immersion NF C 15-100, ACS guaranteed for contact with drinking water

190

Patented


DIMENSIONS AND WEIGHT Typical installation Safety cable anchorage point

PORT

DIMENSIONS mm

DN

N° STAGES

Ø

kg h

1~

4BLOCKm 2/10

10

705

12.5

4BLOCKm 2/13

13

786

14.3

4BLOCKm 2/20

20

986

17.8

4BLOCKm 4/7

7

674

12.1

743

13.8

4BLOCKm 4/14

14

925

17.0

4BLOCKm 6/4

4

641

10.7

4BLOCKm 6/6

6

725

13.3

4BLOCKm 6/9

9

887

16.5

4BLOCKm 4/9

1¼”

9

100

STATIC LEVEL DYNAMIC LEVEL

h

MODEL Single-phase

Ø DN

min. 1 metre

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

4BLOCKm – 0.55 kW

5.0 A

5.0 A

4BLOCKm – 0.75 kW

6.0 A

6.0 A

4BLOCKm – 1.1 kW

8.0 A

8.0 A

PALLETIZATION MODEL

GROUPAGE / CONTAINER n° pumps

H (mm)

kg 1~

4BLOCKm 2/10

60

1260

767

4BLOCKm 2/13

40

1240

589

4BLOCKm 2/20

40

1240

729

4BLOCKm 4/7

60

1260

743

4BLOCKm 4/9

40

1240

569

Single-phase

1240

697

60

1260

659

4BLOCKm 6/6

60

1260

815

4BLOCKm 6/9

40

1240

677

0

40

80

4BLOCKm 4/14 4BLOCKm 6/4

H

00

12

191


4SR 4” submersible pumps

PERFORMANCE RANGE

•• Flow rate up to 375 l/min (22.5 m³/h) •• Head up to 405 m

APPLICATION LIMITS

•• Maximum liquid temperature +35 °C •• Maximum sand content 150 g/m³ •• 100 m immersion limit •• Installation:

•• •• ••

– vertical – horizontal, with the following limits: 4SR1 - 4SR1.5 - 4SR2 - 4SR4 up to 27 stages 4SR6 - 4SR8 - 4SR10 - 4SR12 - 4SR15 up to 17 stages Starts/hour: 20 at regular intervals Minimum flow rate for motor cooling 8 cm/s Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS ELECTRIC MOTOR – Single-phase 230 V - 50 Hz – Three-phase 400 V - 50 Hz Length of power cable: – 1.5 m for powers from 0.37 to 2.2 kW (3 kW 4SR-FK) – 2.5 m for powers from 3 to 5.5 kW (from 4 kW to 7.5 kW 4SR-FK) – 3.5 m for power from 7.5 kW 4SR-PD ➠ The 4SR-PD single-phase versions come with a capacitor included in the packaging. EN 60335-1 IEC 60335-1 CEI 61-150

192

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Suitable for use with clean water with a sand content of no more than 150 g/m³. As a result of their high efficiency and reliability, they are suitable for use in domestic, civil and industrial applications such as for the distribution of water in combination with pressure sets, for irrigation, for washing plants and for pressure boosting in fire-fighting sets, etc.

PATENTS - TRADE MARKS - MODELS

•• Patent Pending n° PCT/EP2009/059855 (cable cover)

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


50 Hz  n= 2900 1/min

Head H (metres) 4

PERFORMANCE RANGE

4SR1 4SR1.5 4SR2 4SR4 4SR6 4SR8 4SR10 4SR12 4SR15

Flow rate Q 4 DESCRIPTION

4 SR 1 m / 13 - PD or FK or HYD

Borehole diameter in inches Series Flow rate in m3/h at the point of highest efficiency Single-phase motor Number of stages PD: pump with “PEDROLLO” motor FK: pump with “FRANKLIN” motor HYD: pump without motor

193


4SR1 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

300

1

2

0

1

3

50 Hz  n= 2900 1/min

4

2

5

3

6

4

7

5

8 6

US g.p.m. 7

Imp g.p.m. feet

275

900

η =43%

4SR1/45

250

800

225 35

700

4SR1/35

200

32

Head H (metres) 4

600

175

4SR1/25

150

500

125

400

4SR1/18

100 300

4SR1/13

75

200

50 100

25

0

0

5

0

0.2

10 0.4

15

0.6

20

0.8

1

25

1.2

1.4

l/min

30 1.6

1.8

2

0

m³/h

Flow rate Q 4 MODEL

POWER

Q

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

l/min

0

5

10

15

20

25

30

73

67

60

51

40

26

101

93

83

71

55

36

98

77

50

136

107

70

137

90

Three-phase

kW

HP

4SR1m/13

4SR1/13

0.37

0.50

77

4SR1m/18

4SR1/18

0.55

0.75

107

4SR1m/25

4SR1/25

0.75

1

148

140

129

115

4SR1m/35

4SR1/35

1.1

1.5

206

197

182

161

4SR1m/45

4SR1/45

1.5

2

266

254

234

207

176

Single-phase

Q = Flow rate H = Total manometric head

194

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


4SR1.5 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

300

1

0

2 1

3 2

4

5

3

50 Hz  n= 2900 1/min  6

4

7

5

8 6

9

10

7

11

8

9

12

US g.p.m.

10

Imp g.p.m. feet

4SR1.5/46

275

900

η =48%

250

800

225 700

4SR1.5/32

200

Head H (metres) 4

600

175

31

4SR1.5/25

28

500

150

125

400

4SR1.5/17

100 300

4SR1.5/13

75 200

4SR1.5/8

50

100

25

0

0 0

5

10

0.2

0.4

0.6

15

20

0.8

1

1.2

25

30

1.4

1.6

35

1.8

2

40 2.2

l/min

45

2.4

2.6

2.8

0

m³/h

Flow rate Q 4 MODEL

POWER

m³/h

0

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

l/min

0

5

10

15

20

25

30

35

40

45

0.50

50

48

46

44

40

36

32

26

20

14

0.75

81

78

75

71

66

59

52

43

33

23

106

102

98

93

86

78

68

56

43

30

156

151

144

136

127

115

100

83

64

45

200

193

184

175

162

147

128

106

82

58

288

277

265

250

233

211

184

153

117

83

Single-phase

Three-phase

kW

HP

4SR1.5m/8

4SR1.5/8

0.37

4SR1.5m/13

4SR1.5/13

0.55

4SR1.5m/17

4SR1.5/17

0.75

1

4SR1.5m/25

4SR1.5/25

1.1

1.5

4SR1.5m/32

4SR1.5/32

1.5

2

4SR1.5m/46

4SR1.5/46

2.2

3

Q = Flow rate H = Total manometric head

Q

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

195


4SR2 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

300

2

4

0

6

2

50 Hz  n= 2900 1/min  8

4

10

6

12

8

14

10

16 US g.p.m. Imp g.p.m.

12

feet

275

900

η =54%

4SR2/39

250

800

225 45

700

200 600

Head H (metres) 4

4SR2/27

175

500

150 4SR2/20 26

125

400

100 4SR2/13

75

4SR2/10

50

4SR2/7

300

200

100

25

0

0

5

0

10

15

0.5

20

25

1

30

1.5

35

40

2

45 2.5

50

55

3

60 3.5

l/min

0

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

0.6

1.2

1.8

2.4

3.0

3.6

l/min

0

10

20

30

40

50

60

4SR2m/7

4SR2/7

0.37

0.50

48

46

44

39

33

25

14

4SR2m/10

4SR2/10

0.55

0.75

70

68

63

57

48

36

20

4SR2m/13

4SR2/13

0.75

1

4SR2m/20

4SR2/20

1.1

1.5

4SR2m/27

4SR2/27

1.5

2

180

4SR2m/39

4SR2/39

2.2

3

260

Q = Flow rate H = Total manometric head

196

H metres

90

88

82

74

62

46

26

135

130

122

111

93

71

39

173

164

150

126

96

52

250

238

216

183

138

75

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


4SR4 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

450

5

0

50 Hz  n= 2900 1/min

10

15

5

20

10

25

15

US g.p.m. Imp g.p.m.

20

feet 1400

η =61%

4SR4/60

400

1300

1200

350 50

1100

4SR4/46

1000

300

Head H (metres) 4

900

250

800 35

4SR4/35

700

200 600

4SR4/26 500

150 4SR4/18

100

400

4SR4/14

300

4SR4/9

50

200

4SR4/7 100

0

0

10

0

0.5

20

30

1

1.5

40 2

50

2.5

60

3

3.5

70 4

80 4.5

90 5

5.5

0

l/min

100 6

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

l/min

0

20

30

40

50

60

70

80

90

100

4SR4m/7

4SR4/7

0.55

0.75

46

44

42

40

38

35

32

28

23

17

4SR4m/9

4SR4/9

0.75

1

60

56

55

52

49

45

40

35

29

23

4SR4m/14

4SR4/14

1.1

1.5

92

88

85

81

76

70

63

55

45

35

4SR4m/18

4SR4/18

1.5

2

120

112

109

104

98

90

81

70

58

45

4SR4m/26

4SR4/26

2.2

3

170

162

157

150

141

130

116

101

84

63

4SR4/35

3

4

230

220

211

202

190

175

157

137

113

85

4SR4/46

4

5.5

308

293

280

269

249

230

205

181

151

117

4SR4/60

5.5

7.5

405

385

370

350

325

300

270

235

195

155

Q = Flow rate H = Total manometric head

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

197


4SR6 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

400

5

0

10 5

15 10

50 Hz  n= 2900 1/min

20

25

15

30

20

35

25

40

US g.p.m.

30

35

Imp g.p.m. feet

η =65%

4SR6/56

375

1200

350 1100

325

55

1000

300 4SR6/42

50

275

900

Head H (metres) 4

250

800

225 4SR6/31

700

200 600

175 4SR6/23

150 125

500

400

4SR6/17

100 4SR6/13

300

4SR6/9

200

75 50

4SR6/6

0

100

4SR6/4

25

0

25

0

1

50 2

75

3

4

100 5

125

6

7

l/min

150 8

9

10

0

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase 4SR6m/4 4SR6/4 4SR6m/6 4SR6/6 4SR6m/9 4SR6/9 4SR6m/13 4SR6/13 4SR6m/17 4SR6/17 – 4SR6/23 – 4SR6/31 – 4SR6/42 – 4SR6/56

POWER kW 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5

Q = Flow rate H = Total manometric head

198

HP 0.75 1 1.5 2 3 4 5.5 7.5 10

Q

m³/h

0

1.5

3.0

4.5

6.0

7.5

9.0

l/min

0

25

50

75

100

125

150

H metres

27

26

24

22

19

15

11

40

38

36

33

29

24

17 26

61

58

54

50

44

35

87

83

78

71

61

49

35

114

107

100

91

79

62

45

154

148

138

128

112

92

67

210

200

186

170

149

121

86

285

276

258

240

212

170

124

380

365

340

315

280

233

173

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


4SR8 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

300

10

50 Hz  n= 2900 1/min

20

0

30

10

40

20

50

30

US g.p.m. Imp g.p.m.

40

feet

η =65% 4SR8/42

275

900

250

800

225 50

700

4SR8/31

200

Head H (metres) 4

600

175 4SR8/23

35

150

500

125

400

4SR8/17

100 4SR8/13

300

4SR8/9

200

75

4SR8/7

50

0

100

4SR8/4

25

0

20

0

1

40

60

2

3

80 4

100 5

6

120 7

140

160

8

9

180 10

l/min

200

11

12

0

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

2.4

3.6

4.8

6.0

7.2

8.4

9.6

10.8

12.0

l/min

0

40

60

80

100

120

140

160

180

200

4SR8m/4

4SR8/4

0.75

1

27

26

25

24

23

22

20

17

13

10

4SR8m/7

4SR8/7

1.1

1.5

47

46

45

43

41

38

34

29

23

16

4SR8m/9

4SR8/9

1.5

2

60

58

57

55

52

48

43

37

30

21

4SR8m/13

4SR8/13

2.2

3

87

85

83

80

76

70

63

54

43

30

4SR8/17

3

4

4SR8/23

4

5.5

4SR8/31

5.5

4SR8/42

7.5

Q = Flow rate H = Total manometric head

H

metres

112

110

108

104

99

92

82

70

56

40

153

150

146

141

134

124

111

95

76

53

7.5

205

200

196

190

181

167

149

128

103

72

10

280

272

266

257

244

225

202

175

140

98

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

199


4SR10 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

240

10

0

20

50 Hz  n= 2900 1/min

30

10

40

20

50

30

40

60

US g.p.m.

50

Imp g.p.m. feet

4SR10/35

η =63%

750

220 700

200

650

600

180 4SR10/26

550 44

160

500

Head H (metres) 4

40

140

450

4SR10/20 400

120

350

100

4SR10/15 300

80

250

4SR10/10 200

60 4SR10/7

40

150

4SR10/5

100

20

0

50

0

25

0

50

75

2

100

4

125

6

150 8

175

200

10

225

12

l/min

250 14

0

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

3.0

4.5

6.0

7.5

9.0

10.5

12

13.5

15.0

l/min

0

50

75

100

125

150

175

200

225

250

4SR10m/5

4SR10/5

1.1

1.5

33

31

30

28

26

24

21

18

14

10

4SR10m/7

4SR10/7

1.5

2

46

43

41

39

37

34

30

25

20

15

4SR10m/10

4SR10/10

2.2

3

66

62

59

56

53

48

42

36

28

20

4SR10/15

3

4

98

92

88

84

79

72

64

53

42

30

4SR10/20

4

5.5

130

123

118

112

106

96

85

71

56

40

4SR10/26

5.5

7.5

170

160

154

147

138

126

110

94

72

52

4SR10/35

7.5

10

230

216

208

197

184

168

148

126

100

70

Q = Flow rate H = Total manometric head

200

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


4SR12 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

200

10

0

20

30

10

20

50 Hz  n= 2900 1/min

40

50

30

60

40

70

50

80 60

US g.p.m. Imp g.p.m.

70

feet

η =58%

4SR12/29

600

175 550

500

150 45

4SR12/22

450 40

Head H (metres) 4

125

400

350

4SR12/16

100

300

4SR12/12

75

250

200

4SR12/9

50

150

4SR12/6 100

4SR12/4

25

50

0

0

50

0

2

100 4

150

6

8

200 10

250

12

14

16

0

l/min

300 18

20

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

3.0

6.0

9.0

12.0

13.2

14.4

15.6

16.8

18.0

l/min

0

50

100

150

200

220

240

260

280

300

4SR12m/4

4SR12/4

1.1

1.5

25

24

22

19

16

15

14

12

11

8

4SR12m/6

4SR12/6

1.5

2

38

37

35

32

28

26

24

21

18

14

4SR12m/9

4SR12/9

2.2

3

4SR12/12

3

4

4SR12/16

4

5.5

100

97

93

86

4SR12/22

5.5

7.5

138

135

127

118

4SR12/29

7.5

10

182

176

167

155

135

Q = Flow rate H = Total manometric head

H metres

56

55

52

48

42

39

36

32

27

22

75

73

69

64

56

52

48

43

36

29

75

70

64

57

48

38

103

96

88

78

66

53

126

116

103

88

71

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

201


4SR15 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

25

50 Hz  n= 2900 1/min  50

0

75

25

US g.p.m.

50

Imp g.p.m.

75

feet 500

4SR15/24

150

η =53% 450

125

400

4SR15/18 40

350

100 Head H (metres) 4

36

300

4SR15/13 250

75 4SR15/10

200

50 150

4SR15/7

4SR15/5

100

25 50

0

0

50

100

0

150

200

5

250

10

300

l/min

350

15

20

0

m³/h

Flow rate Q 4 MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

3.0

6.0

9.0

12.0

15.0

18.0

21.0

22.5

l/min

0

50

100

150

200

250

300

350

375

4SR15m/5

4SR15/5

1.5

2

31

30

28

26

23

20

15

10

7.5

4SR15m/7

4SR15/7

2.2

3

44

42

40

37

32

27

20

13

10

4SR15/10

3

4

4SR15/13

4

5.5

4SR15/18

5.5

4SR15/24

7.5

Q = Flow rate H = Total manometric head

202

62

60

57

52

46

38

30

20

15

80

77

72

68

60

50

40

25

19

7.5

112

108

102

95

85

71

55

37

27

10

150

145

138

126

112

95

75

50

36

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


4SR POS. COMPONENT 1

DELIVERY BODY

CONSTRUCTION CHARACTERISTICS Precision cast stainless steel AISI 304, complete with threaded delivery port in compliance with ISO 228/1

1

2

NON-RETURN VALVE

Stainless steel AISI 304

2

3

MOTOR BRACKET

Stainless steel AISI 304, in compliance with NEMA standards

8

4

IMPELLER

Lexan 141-R

5

DIFFUSER

Noryl GFN2V

6

STAGE CASING

Stainless steel AISI 304

7

PUMP SHAFT

Stainless steel AISI 304

8

PUMP BEARINGS

Special-technopolymer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing

4 5

6

11

9

DRIVE COUPLING

Stainless steel AISI 316L up to 2.2 kW; stainless steel AISI 304 for higher powers

7

10

FILTER

Stainless steel AISI 304

10

11

CABLE COVER

Stainless steel AISI 304

12

MOTOR 4"

4PD = "PEDROLLO" 4FK = "FRANKLIN"

9

3

12

203


4SR-PD

Submersible pumps with “PEDROLLO” motors DIMENSIONS AND WEIGHT Ø

MODEL Three-phase

h2

h

h1

Safety cable anchorage point

DN

MODEL Single-phase 4SR1m/13 - PD 4SR1m/18 - PD 4SR1m/25 - PD 4SR1m/35 - PD 4SR1m/45 - PD 4SR1.5m/8 - PD 4SR1.5m/13 - PD 4SR1.5m/17 - PD 4SR1.5m/25 - PD 4SR1.5m/32 - PD 4SR1.5m/46 - PD 4SR2m/7 - PD 4SR2m/10 - PD 4SR2m/13 - PD 4SR2m/20 - PD 4SR2m/27 - PD 4SR2m/39 - PD 4SR4m/7 - PD 4SR4m/9 - PD 4SR4m/14 - PD 4SR4m/18 - PD 4SR4m/26 - PD 4SR6m/4 - PD 4SR6m/6 - PD 4SR6m/9 - PD 4SR6m/13 - PD 4SR6m/17 - PD 4SR8m/4 - PD 4SR8m/7 - PD 4SR8m/9 - PD 4SR8m/13 - PD 4SR10m/5 - PD 4SR10m/7 - PD 4SR10m/10 - PD 4SR12m/4 - PD 4SR12m/6 - PD 4SR12m/9 - PD 4SR15m/5 - PD 4SR15m/7 - PD

204

PORT DN

DIMENSIONS mm Ø

h1

h2

h

1~

98

400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 281 341 431 576 695 281 371 431 576 416 518 709 365 467 658 421 525

311 331 356 386 436 311 331 356 386 436 481 311 331 356 386 436 481 331 356 386 436 481 331 356 386 436 481 356 386 436 481 386 436 481 386 436 481 436 481

711 848 1002 1242 1501 619 731 855 1032 1236 1615 601 676 756 940 1119 1410 645 714 854 1016 1237 612 697 817 1012 1176 637 757 867 1057 802 954 1190 751 903 1139 857 1006

11.0 13.1 15.8 20.1 23.6 10.1 13.1 14.3 18.5 22.4 28.7 9.9 11.1 13.2 16.8 19.5 26.0 10.7 12.5 15.7 18.0 22.3 11.4 12.2 15.1 17.6 22.3 11.6 14.6 16.3 20.9 15.5 16.9 21.8 15.0 15.8 21.8 16.7 20.8

1¼"

2"

kg

4SR1/13 - PD 4SR1/18 - PD 4SR1/25 - PD 4SR1/35 - PD 4SR1/45 - PD 4SR1.5/8 - PD 4SR1.5/13 - PD 4SR1.5/17 - PD 4SR1.5/25 - PD 4SR1.5/32 - PD 4SR1.5/46 - PD 4SR2/7 - PD 4SR2/10 - PD 4SR2/13 - PD 4SR2/20 - PD 4SR2/27 - PD 4SR2/39 - PD 4SR4/7 - PD 4SR4/9 - PD 4SR4/14 - PD 4SR4/18 - PD 4SR4/26 - PD 4SR4/35 - PD 4SR4/46 - PD 4SR4/60 - PD 4SR6/4 - PD 4SR6/6 - PD 4SR6/9 - PD 4SR6/13 - PD 4SR6/17 - PD 4SR6/23 - PD 4SR6/31 - PD 4SR6/42 - PD 4SR6/56 - PD 4SR8/4 - PD 4SR8/7 - PD 4SR8/9 - PD 4SR8/13 - PD 4SR8/17 - PD 4SR8/23 - PD 4SR8/31 - PD 4SR8/42 - PD 4SR10/5 - PD 4SR10/7 - PD 4SR10/10 - PD 4SR10/15 - PD 4SR10/20 - PD 4SR10/26 - PD 4SR10/35 - PD 4SR12/4 - PD 4SR12/6 - PD 4SR12/9 - PD 4SR12/12 - PD 4SR12/16 - PD 4SR12/22 - PD 4SR12/29 - PD 4SR15/5 - PD 4SR15/7 - PD 4SR15/10 - PD 4SR15/13 - PD 4SR15/18 - PD 4SR15/24 - PD

PORT DN

DIMENSIONS mm Ø

h1

h2

h

3~

98

400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 978 1295 1652 281 341 431 576 695 900 1164 1519 2063 281 371 431 576 695 900 1164 1519 416 518 709 1001 1256 1599 2095 365 467 658 810 1052 1358 1752 421 525 719 874 1172 1521

311 331 356 354 428 311 331 356 354 428 436 311 331 356 354 428 436 331 356 354 428 467 522 587 687 331 356 354 428 467 522 587 687 768 356 354 428 467 522 587 687 768 354 428 467 522 587 687 768 354 428 467 522 587 687 768 428 467 522 587 687 768

711 848 1002 1210 1493 619 731 855 1000 1228 1570 601 676 756 908 1111 1365 645 714 822 1008 1223 1500 1882 2339 612 697 785 1004 1162 1422 1751 2206 2831 637 725 859 1043 1217 1487 1851 2287 770 946 1176 1523 1843 2286 2863 719 895 1125 1332 1639 2045 2520 849 992 1241 1461 1859 2289

13.0 14.4 17.1 19.9 23.0 10.1 11.7 14.3 17.8 24.3 25.4 9.8 11.3 13.3 16.7 19.9 22.7 12.2 12.5 15.8 17.6 19.1 26.1 34.3 45.1 10.8 13.1 14.9 17.2 18.0 24.6 32.0 40.7 51.7 12.6 13.7 16.0 16.9 24.0 27.6 36.6 44.6 15.3 16.9 19.1 25.6 33.4 41.4 49.4 13.5 17.7 18.8 24.4 28.9 37.5 46.5 16.1 16.5 24.5 27.3 36.3 43.7

1¼"

2"

kg


4SR-FK

Submersible pumps with “FRANKLIN” motors

DIMENSIONS AND WEIGHT Ø

MODEL

DN Safety cable anchorage point

h2

h

h1

Three-phase

MODEL Single-phase 4SR1m/13 - FK 4SR1m/18 - FK 4SR1m/25 - FK 4SR1m/35 - FK 4SR1m/45 - FK 4SR1.5m/8 - FK 4SR1.5m/13 - FK 4SR1.5m/17 - FK 4SR1.5m/25 - FK 4SR1.5m/32 - FK 4SR1.5m/46 - FK 4SR2m/7 - FK 4SR2m/10 - FK 4SR2m/13 - FK 4SR2m/20 - FK 4SR2m/27 - FK 4SR2m/39 - FK 4SR4m/7 - FK 4SR4m/9 - FK 4SR4m/14 - FK 4SR4m/18 - FK 4SR4m/26 - FK 4SR6m/4 - FK 4SR6m/6 - FK 4SR6m/9 - FK 4SR6m/13 - FK 4SR6m/17 - FK 4SR8m/4 - FK 4SR8m/7 - FK 4SR8m/9 - FK 4SR8m/13 - FK 4SR10m/5 - FK 4SR10m/7 - FK 4SR10m/10 - FK 4SR12m/4 - FK 4SR12m/6 - FK 4SR12m/9 - FK 4SR15m/5 - FK 4SR15m/7 - FK

PORT DN

DIMENSIONS mm Ø

h1

h2

h

1~

98

400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 281 341 431 576 695 281 371 431 576 416 518 709 365 467 658 421 525

242 271 298 327 356 242 271 298 327 356 460 242 271 298 327 356 460 271 298 327 356 460 271 298 327 356 460 298 327 356 460 327 356 460 327 356 460 356 460

642 788 944 1183 1421 550 671 797 973 1156 1594 532 616 698 881 1039 1389 585 656 795 936 1216 552 639 758 932 1155 579 698 787 1036 743 874 1169 692 823 1118 777 985

13.0 15.4 18.6 21.8 25.4 12.6 14.9 16.9 19.9 22.8 31.7 11.6 13.5 15.3 18.0 21.1 28.1 13.1 14.7 17.1 20.5 25.7 13.8 14.6 16.6 19.4 25.8 14.1 16.1 16.6 24.5 17.0 19.3 25.4 16.6 18.8 25.2 18.5 23.8

1¼"

2"

kg

4SR1/13 - FK 4SR1/18 - FK 4SR1/25 - FK 4SR1/35 - FK 4SR1/45 - FK 4SR1.5/8 - FK 4SR1.5/13 - FK 4SR1.5/17 - FK 4SR1.5/25 - FK 4SR1.5/32 - FK 4SR1.5/46 - FK 4SR2/7 - FK 4SR2/10 - FK 4SR2/13 - FK 4SR2/20 - FK 4SR2/27 - FK 4SR2/39 - FK 4SR4/7 - FK 4SR4/9 - FK 4SR4/14 - FK 4SR4/18 - FK 4SR4/26 - FK 4SR4/35 - FK 4SR4/46 - FK 4SR4/60 - FK 4SR6/4 - FK 4SR6/6 - FK 4SR6/9 - FK 4SR6/13 - FK 4SR6/17 - FK 4SR6/23 - FK 4SR6/31 - FK 4SR6/42 - FK 4SR6/56 - FK 4SR8/4 - FK 4SR8/7 - FK 4SR8/9 - FK 4SR8/13 - FK 4SR8/17 - FK 4SR8/23 - FK 4SR8/31 - FK 4SR8/42 - FK 4SR10/5 - FK 4SR10/7 - FK 4SR10/10 - FK 4SR10/15 - FK 4SR10/20 - FK 4SR10/26 - FK 4SR10/35 - FK 4SR12/4 - FK 4SR12/6 - FK 4SR12/9 - FK 4SR12/12 - FK 4SR12/16 - FK 4SR12/22 - FK 4SR12/29 - FK 4SR15/5 - FK 4SR15/7 - FK 4SR15/10 - FK 4SR15/13 - FK 4SR15/18 - FK 4SR15/24 - FK

PORT DN

DIMENSIONS mm Ø

h1

h2

h

3~

98

400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 978 1295 1652 281 341 431 576 695 900 1164 1519 2063 281 371 431 576 695 900 1164 1519 416 518 709 1001 1256 1599 2095 365 467 658 810 1052 1358 1752 421 525 719 874 1172 1521

223 242 271 298 327 223 242 271 298 327 356 223 242 271 298 327 356 242 271 298 327 356 423 583 698 242 271 298 327 356 423 583 698 774 271 298 327 356 423 583 698 774 298 327 356 423 583 698 774 298 327 356 423 583 698 774 327 356 423 583 698 774

623 759 917 1154 1392 531 642 770 944 1127 1490 513 587 671 852 1010 1285 556 629 766 907 1112 1401 1878 2350 523 612 729 903 1051 1323 1747 2217 2837 552 669 758 932 1118 1483 1862 2293 714 845 1065 1424 1839 2297 2869 663 794 1014 1233 1635 2056 2526 748 881 1142 1457 1870 2295

13.2 14.7 17.2 20.7 24.0 11.6 13.6 16.9 18.3 21.8 27.2 10.8 11.8 13.5 16.3 20.4 24.1 11.4 13.5 15.4 17.3 20.4 26.5 39.6 49.3 12.5 12.8 14.9 18.2 20.2 24.5 36.4 44.9 55.5 12.3 14.4 15.9 18.5 22.8 33.9 41.7 48.4 15.7 17.9 20.4 26.1 36.6 45.0 53.2 15.3 17.4 20.6 26.2 34.2 42.7 48.4 17.1 19.3 23.5 33.0 41.0 47.5

1¼"

2"

kg

205


4SR-HYD DIMENSIONS AND WEIGHT  (PUMP ONLY) MODEL

Ø

Pump

DN

206

h

h1

Safety cable anchorage point

4SR1/13 - HYD 4SR1/18 - HYD 4SR1/25 - HYD 4SR1/35 - HYD 4SR1/45 - HYD 4SR1.5/8 - HYD 4SR1.5/13 - HYD 4SR1.5/17 - HYD 4SR1.5/25 - HYD 4SR1.5/32 - HYD 4SR1.5/46 - HYD 4SR2/7 - HYD 4SR2/10 - HYD 4SR2/13 - HYD 4SR2/20 - HYD 4SR2/27 - HYD 4SR2/39 - HYD 4SR4/7 - HYD 4SR4/9 - HYD 4SR4/14 - HYD 4SR4/18 - HYD 4SR4/26 - HYD 4SR4/35 - HYD 4SR4/46 - HYD 4SR4/60 - HYD 4SR6/4 - HYD 4SR6/6 - HYD 4SR6/9 - HYD 4SR6/13 - HYD 4SR6/17 - HYD 4SR6/23 - HYD 4SR6/31 - HYD 4SR6/42 - HYD 4SR6/56 - HYD 4SR8/4 - HYD 4SR8/7 - HYD 4SR8/9 - HYD 4SR8/13 - HYD 4SR8/17 - HYD 4SR8/23 - HYD 4SR8/31 - HYD 4SR8/42 - HYD 4SR10/5 - HYD 4SR10/7 - HYD 4SR10/10 - HYD 4SR10/15 - HYD 4SR10/20 - HYD 4SR10/26 - HYD 4SR10/35 - HYD 4SR12/4 - HYD 4SR12/6 - HYD 4SR12/9 - HYD 4SR12/12 - HYD 4SR12/16 - HYD 4SR12/22 - HYD 4SR12/29 - HYD 4SR15/5 - HYD 4SR15/7 - HYD 4SR15/10 - HYD 4SR15/13 - HYD 4SR15/18 - HYD 4SR15/24 - HYD

PORT DN

DIMENSIONS mm Ø

h1

h

98

400 517 646 856 1065 308 400 499 646 800 1134 290 345 400 554 683 929 314 358 468 580 756 978 1295 1652 281 341 431 576 695 900 1164 1519 2063 281 371 431 576 695 900 1164 1519 416 518 709 1001 1256 1599 2095 365 467 658 810 1052 1358 1752 421 525 719 874 1172 1521

403 520 649 859 1068 311 403 502 649 803 1137 293 348 403 557 686 932 317 361 471 583 759 981 1298 1655 284 344 434 579 698 903 1167 1522 2066 284 374 434 579 698 903 1167 1522 419 521 712 1004 1259 1602 2098 368 470 661 813 1055 1361 1755 424 528 722 877 1175 1524

1¼"

2"

kg 4.7 5.9 7.4 9.4 11.4 3.8 4.8 5.7 7.3 9.2 13.2 3.6 4.2 4.8 7.0 7.7 10.5 3.8 4.3 5.4 6.6 8.3 10.7 15.0 19.4 3.7 4.0 4.8 6.1 7.1 9.3 11.8 15.0 22.0 3.5 4.2 4.7 6.1 7.2 9.3 11.8 14.9 4.4 5.3 6.9 9.5 12.0 15.7 19.7 4.0 4.8 6.6 8.1 9.6 12.8 15.9 4.5 5.3 7.0 8.4 11.1 14.0


4SR INSTALLATION EXAMPLE

5 9

11

12

7

8

8

5

4

4

6

6

DYNAMIC LEVEL

7

STATIC LEVEL

STATIC LEVEL

3

DYNAMIC LEVEL

2

2

1

1

min. 1 metre

min. 1 metre

COMPONENTS 1) Submersible pump 2) Power cable clamps 3) Level probes; prevent dry running 4) Pump anchorage 5) Pressure gauge 6) Non-return valve 7) Gate valve; for flow rate regulation

10

8) Power cable 9) Control box 10) Pressure vessel 11) Pressure switch 12) Electro valve/electro-compressor

➠The 4SR series pumps should be installed in boreholes of at least 4� (100 mm) in diameter. The pump should be lowered into the borehole, by means of the delivery pipe, to such a depth (min. 50 cm and at least one metre from the bottom) that it is completely immersed during operation when the level of water in the borehole may reduce. It is good practice to secure the pump by attaching a stainless steel cable to the anchorage points present on the delivery body.

207


6SR 6” submersible pumps

PERFORMANCE RANGE

•• Flow rate up to 1000 l/min (60 m³/h) •• Head up to 390 m

APPLICATION LIMITS

•• Maximum liquid temperature +35 °C •• Maximum sand content 100 g/m³ •• 100 m immersion limit •• Installation:

•• •• ••

– vertical – horizontal, with the following limits: up to 12 stages or 11 kW Starts/hour: 20 at regular intervals Minimum flow rate for motor cooling 16 cm/s (0.5 m/s for 30 kW) Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS ELECTRIC MOTOR – Three-phase 400 V - 50 Hz

INSTALLATION AND USE Suitable for use with clean water with a sand content of no more than 100 g/m³. As a result of their high efficiency and reliability, they are suitable for use in civil, agricultural and industrial applications such as for the distribution of water in combination with pressure sets, for irrigation and for pressure boosting in fire-fighting sets, etc.

4 m long power cable

OPTIONALS AVAILABLE ON REQUEST

EN 60034-1 IEC 60034-1 CEI 2-3

•• Other voltages or 60 Hz frequency

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

208

•• 6SR-HYD pumps with double cable cover suitable for adual voltage 400/690 V (star/delta) motors from 11 kW to 30 kW

GUARANTEE 1 year subject to terms and conditions


50 Hz  n= 2900 1/min

Head H (metres) 4

PERFORMANCE RANGE

6SR12 6SR18 6SR27 6SR36 6SR44

Flow rate Q 4

DESCRIPTION

6 SR 12 / 8 - PD or HYD

Borehole diameter in inches Series Flow rate in m3/h at the point of highest efficiency Number of stages PD: pump with “PEDROLLO” motor HYD: pump without motor

209


6SR12 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

450

10

0

20 10

30 20

50 Hz  n= 2900 1/min

40

50

30

60

40

70

50

80 60

90

US g.p.m.

70

80

Imp g.p.m. feet

η =67% 1400

400

1300

6SR12/28

1200

6SR12/25

350

1100

52

1000

300

47

6SR12/21

Head H (metres) 4

900

6SR12/18

250

800

700

6SR12/15

200 600

6SR12/11

150

500

400

6SR12/8

100

300

200

50 100

0

0 0

50 2

100 4

6

150 8

200 10

250

12

14

300 16

l/min

350

18

20

22

0

m³/h

Flow rate Q 4 MODEL

POWER

m³/h

0

3.0

6.0

9.0

12.0

15.0

18.0

19.8

l/min

0

50

100

150

200

250

300

330

HP

6SR12/8

4

5.5

111

106

100

91

80

66

47

32

6SR12/11

5.5

7.5

153

146

138

125

110

91

65

44

6SR12/15

7.5

10

6SR12/18

9.2

12.5

H metres

208

199

189

171

150

124

88

60

250

239

225

205

180

149

106

72

6SR12/21

11

15

292

279

263

239

210

174

124

84

6SR12/25

13

17.5

349

331

313

285

250

206

147

100

6SR12/28

15

20

390

371

350

319

280

231

165

112

Q = Flow rate H = Total manometric head

210

Q

kW

Three-phase

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


6SR18 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

400

20

40

0

50 Hz  n= 2900 1/min  60

20

80

40

100

60

80

120

US g.p.m.

100

Imp g.p.m. feet

350

1200

η =71%

6SR18/26

1100

100

6SR18/22

300

58

900

Head H (metres) 4

250

50

6SR18/18

800

700

6SR18/15

200

150

6SR18/13

600

6SR18/11

500

6SR18/9

400

100

300

6SR18/6

6SR18/4

200

50 100

0

0

50

100

0

150

5

200

250

10

300

350

15

400

20

0

l/min

450 25

m³/h

Flow rate Q 4 MODEL

POWER

Q

m³/h

0

3

6

9

12

15

18

21

24

27

l/min

0

50

100

150

200

250

300

350

400

450

53

51

49

46

42

37

30

22

79

77

74

69

63

55

45

32

kW

HP

6SR18/4

4

5.5

54

53.8

6SR18/6

5.5

7.5

81

80.5

Three-phase

6SR18/9

7.5

10

122

121

119

116

111

103

94

83

68

48

6SR18/11

9.2

12.5

149

148

145.5

141

135

126

115

101

83

59

H metres

6SR18/13

11

15

176

175

172

167

160

149

136

120

98

70

6SR18/15

13

17.5

203

202

199

193

185

172

157

138

113

80

6SR18/18

15

20

244

242

238

231

221

206

188

165

135

96

6SR18/22

18.5

25

298

296

291

282

270

252

230

202

165

118

6SR18/26

22

30

352

350

344

334

320

298

272

239

195

139

Q = Flow rate H = Total manometric head

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

211


6SR27 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

400

20

40

0

60

20

50 Hz  n= 2900 1/min

80

40

100

60

120

80

140

100

160 120

US g.p.m. 140

Imp g.p.m. feet

η =68%

6SR27/27

1200

350 1100

100

56

300 6SR27/20

900

Head H (metres) 4

250

800

41

6SR27/17

700

200

6SR27/14 600

6SR27/12 500

150 6SR27/10

400

6SR27/8

100

6SR27/7

300

6SR27/5 200

6SR27/4

50 100

0

0 0

100

200

5

10

300

400

15

20

500 25

l/min

600

30

35

40

0

m³/h

Flow rate Q 4 MODEL Three-phase 6SR27/4 6SR27/5 6SR27/7 6SR27/8 6SR27/10 6SR27/12 6SR27/14 6SR27/17 6SR27/20 6SR27/27

POWER kW 4 5.5 7.5 9.2 11 13 15 18.5 22 30

HP 5.5 7.5 10 12.5 15 17.5 20 25 30 40

Q = Flow rate H = Total manometric head

212

Q

m³/h

0

6

12

18

24

30

36

l/min

0

100

200

300

400

500

600

54 68 95 109 136 164 191 231 272 367

53 66 92 106 132 159 185 224 264 356

49 62 87 99 124 149 174 211 248 335

45 57 80 91 114 137 160 194 228 308

40 50 70 80 100 120 140 170 200 270

30 37 52 59 74 89 104 126 148 205

18 22 31 35 44 53 62 75 88 119

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


6SR36 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

300

20

0

40

60

20

80

40

50 Hz  n= 2900 1/min

100

60

120

80

140

100

160

120

180 140

200 160

220 US g.p.m. Imp g.p.m.

180

feet

η =73%

275

900

6SR36/23

250

800

225

6SR36/19

59

700

Head H (metres) 4

200 600

6SR36/15

175

6SR36/13

150

500

6SR36/11

125

400

6SR36/10

100

31

6SR36/8

75

300

6SR36/6 200

6SR36/4

50

100

25

0

0 0

100

200

5

10

300 15

400 20

500

25

600

30

35

700 40

45

0

l/min

800 50

m³/h

Flow rate Q 4 MODEL Three-phase 6SR36/4 6SR36/6 6SR36/8 6SR36/10 6SR36/11 6SR36/13 6SR36/15 6SR36/19 6SR36/23

POWER kW 4 5.5 7.5 9.2 11 13 15 18.5 22

HP 5.5 7.5 10 12.5 15 17.5 20 25 30

Q = Flow rate H = Total manometric head

Q

m³/h

0

6

12

18

24

30

36

42

48

l/min

0

100

200

300

400

500

600

700

800

47 70 94 117 129 152 176 222 269

45 67 89 111 123 145 167 212 256

42 63 84 105 115 136 157 199 241

38 57 76 95 105 124 143 181 219

34 51 68 85 93 110 127 161 195

29 44 59 74 81 96 110 140 169

25 37 50 62 68 81 93 118 143

19 29 39 48 53 63 72 92 111

14 20 27 34 37 44 51 65 78

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

213


6SR44 CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

275

50

0

50 Hz  n= 2900 1/min

100

150

50

200

100

250

150

US g.p.m. Imp g.p.m.

200

feet

η =73%

250

6SR44/21

800

225 700

200

57

6SR44/16

600

Head H (metres) 4

175

6SR44/13

150

500 40

6SR44/11

125

400

6SR44/9

100

6SR44/8

75

300

6SR44/6 200

6SR44/5

50

6SR44/4 6SR44/3 100

25

0

0 0

MODEL Three-phase 6SR44/3 6SR44/4 6SR44/5 6SR44/6 6SR44/8 6SR44/9 6SR44/11 6SR44/13 6SR44/16 6SR44/21

100 5

200 10

15

POWER kW 4 5.5 7.5 9.2 11 13 15 18.5 22 30

HP 5.5 7.5 10 12.5 15 17.5 20 25 30 40

Q = Flow rate H = Total manometric head

214

300

Q

400 20

500

25

600

30

700

35

40

Flow rate Q 4

800 45

900 50

1000

55

60

l/min

0

m³/h

m³/h

0

12

18

24

30

36

42

48

54

60

l/min

0

200

300

400

500

600

700

800

900

1000

35 47 58 70 93 105 128 151 186 244

33 44 54 65 87 98 120 141 174 228

31 42 52 62 83 93 114 135 166 218

30 40 49 59 79 89 109 128 158 207

28 37 46 56 74 83 102 120 148 194

26 34 43 51 68 77 94 111 136 179

23 31 38 46 61 69 84 99 122 160

20 27 33 40 53 60 73 86 106 139

17 23 28 34 45 51 62 73 90 118

13 18 22 26 35 39 48 57 70 92

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.


6SR INSTALLATION EXAMPLE 9

12

8

11

5

4 6

10

➠The 6SR series pumps should be installed in boreholes of at least 6� (150 mm) in diameter. The pump should be lowered into the borehole, by means of the delivery pipe, to such a depth (min. 50 cm and at least one metre from the bottom) that it is completely immersed during operation when the level of water in the borehole may reduce. It is good practice to secure the pump by attaching a stainless steel cable to the anchorage points present on the delivery body.

7

STATIC LEVEL DYNAMIC LEVEL

3

2

1

COMPONENTS 1) Submersible pump 2) Power cable clamps 3) Level probes 4) Pump anchorage 5) Pressure gauge 6) Non-return valve 7) Gate valve; for flow rate regulation 8) Power cable 9) Control box 10) Pressure vessel 11) Pressure switch 12) Electro valve/electro-compressor

min. 1 metre

Vertical installation

Cooling jacket Minimum height 0.5 metres

Cooling jacket

It is necessary to fit the pump with a cooling jacket in installations in storage tanks, rivers and lakes in order to prevent the motor from overheating.

215


6SR12-18-27 POS. COMPONENT 1

DELIVERY BODY

(Radial impellers)

CONSTRUCTION CHARACTERISTICS Nickel-plated cast iron complete with threaded delivery port in compliance with ISO 228/1

11 1

2

NON-RETURN VALVE

Stainless steel AISI 304

3

MOTOR BRACKET

Nickel-plated cast iron, in compliance with NEMA standards

8

2

4

IMPELLERS

Special-rubber coated Noryl GFN2V

4

5

DIFFUSERS

Noryl GFN2V

5

6

DIFFUSOR CASING

Stainless steel AISI 304

6

7

PUMP SHAFT

Stainless steel AISI 304

8

PUMP BEARINGS

Special elastomer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing

9

DRIVE COUPLING

7

Stainless steel AISI 420

10 FILTER

Stainless steel AISI 304

11 CABLE COVER

Stainless steel AISI 304

12 MOTOR 6"

6PD = "PEDROLLO"

10 9 3

12

216


6SR36-44 POS. COMPONENT 1

DELIVERY BODY

(Semi-axial impellers)

CONSTRUCTION CHARACTERISTICS Stainless steel AISI 304 complete with threaded delivery port in compliance with ISO 228/1

1

2

NON-RETURN VALVE

Stainless steel AISI 304

2

3

MOTOR BRACKET

Nickel-plated cast iron, in compliance with NEMA standards

8

4

IMPELLERS

Special-rubber coated Noryl GFN2V

5

DIFFUSERS

Noryl GFN2V

5

11

4

6

DIFFUSOR CASING

Stainless steel AISI 304

7

PUMP SHAFT

Stainless steel AISI 304

8

PUMP BEARINGS

Special-technopolymer housing with stainless steel AISI 316, chrome oxide coated, sand resistant shaft bushing

9

DRIVE COUPLING

10 FILTER

Stainless steel AISI 420

6

7

10

Stainless steel AISI 304 3

11 CABLE COVER

Stainless steel AISI 304

12 MOTOR 6"

6PD = "PEDROLLO"

9

12

217


6SR-PD DIMENSIONS AND WEIGHT Ø

MODEL

DN

Three-phase

Safety cable anchorage point

PORT DN

DIMENSIONS mm Ø

h

h1

6 SR 12/8 - PD

h2

h

3~

633

1352

53.8

849

667

1516

60.9

6 SR 12/15 - PD

1068

698

1766

66.8

6 SR 12/18 - PD

1198

731

1929

73.0

6 SR 12/21 - PD

1328

826

2154

83.9

6 SR 12/25 - PD

1502

894

2396

96.0

6 SR 12/28 - PD

1632

894

2526

98.1

6 SR 18/4 - PD

545

633

1178

49.6

6 SR 18/6 - PD

632

667

1299

53.6

6 SR 18/9 - PD

762

698

1460

60.3

6 SR 18/11 - PD

849

731

1580

67.0

6 SR 18/13 - PD

981

826

1807

76.9

6 SR 18/15 - PD

1068

894

1962

84.6

6 SR 18/18 - PD

1198

894

2092

87.6

6 SR 18/22 - PD

1371

959

2330

99.7

6 SR 18/26 - PD

1545

1116

2661

125.7

6 SR 27/4 - PD

583

633

1216

47.9

6 SR 27/5 - PD

636

667

1303

53.5

6 SR 27/7 - PD

742

698

1440

58.8

6 SR 27/8 - PD

795

731

1526

63.0

6 SR 27/10 - PD

901

826

1727

74.1

1051

894

1945

83.6

1157

894

2051

85.9

6 SR 27/12 - PD

h2

h1 719

6 SR 12/11 - PD

6 SR 27/14 - PD

218

kg

3"

149.5

6 SR 27/17 - PD

1316

959

2275

97.5

6 SR 27/20 - PD

1474

1116

2590

123.0

6 SR 27/27 - PD

1845

1243

3088

135.8

6 SR 36/4 - PD

823

633

1456

55.4

6 SR 36/6 - PD

1049

667

1716

64.0

6 SR 36/8 - PD

1275

698

1973

71.0

6 SR 36/10 - PD

1501

731

2232

76.2

6 SR 36/11 - PD

1613

826

2439

90.0

6 SR 36/13 - PD

1839

894

2733

102.0

6 SR 36/15 - PD

2065

894

2959

107.0

6 SR 36/19 - PD

2517

959

3476

121.0

6 SR 36/23 - PD

2969

1116

4085

154.0

6 SR 44/3 - PD

710

633

1343

54.0

6 SR 44/4 - PD

823

667

1490

57.5

6 SR 44/5 - PD

936

698

1634

63.1

6 SR 44/6 - PD

1049

731

1780

70.0

6 SR 44/8 - PD

1275

826

2101

82.2

6 SR 44/9 - PD

1388

894

2282

92.0

6 SR 44/11 - PD

1613

894

2507

97.0

6 SR 44/13 - PD

1839

959

2798

110.0

6 SR 44/16 - PD

2178

1116

3294

141.0

6 SR 44/21 - PD

2743

1243

3986

154.3


6SR-HYD DIMENSIONS AND WEIGHT Ø

MODEL

DN

Pump

Safety cable anchorage point

PORT DN

DIMENSIONS mm Ø

h

6 SR 12/8 - HYD

h

kg

719

19.8

6 SR 12/11 - HYD

849

24.9

6 SR 12/15 - HYD

1068

27.8

6 SR 12/18 - HYD

1198

31.0

6 SR 12/21 - HYD

1328

33.9

6 SR 12/25 - HYD

1502

39.0

6 SR 12/28 - HYD

1632

41.1

6 SR 18/4 - HYD

545

15.6

6 SR 18/6 - HYD

632

17.6

6 SR 18/9 - HYD

762

21.3

6 SR 18/11 - HYD

849

25.0

6 SR 18/13 - HYD

981

26.9

6 SR 18/15 - HYD

1068

27.6

6 SR 18/18 - HYD

1198

30.6

6 SR 18/22 - HYD

1371

34.7

6 SR 18/26 - HYD

1545

38.7

6 SR 27/4 - HYD

583

13.9

6 SR 27/5 - HYD

636

17.5

6 SR 27/7 - HYD

742

19.8

6 SR 27/8 - HYD

795

21.0

6 SR 27/10 - HYD

901

24.1

6 SR 27/12 - HYD

1051

26.6

1157

28.9

6 SR 27/17 - HYD

1316

32.5

6 SR 27/20 - HYD

1474

36.0

6 SR 27/27 - HYD

1845

44.8

6 SR 36/4 - HYD

823

21.4

6 SR 36/6 - HYD

1049

28.0

6 SR 36/8 - HYD

1275

32.0

6 SR 36/10 - HYD

1501

34.2

6 SR 36/11 - HYD

1613

40.0

6 SR 36/13 - HYD

1839

45.0

6 SR 27/14 - HYD

3"

149.5

6 SR 36/15 - HYD

2065

50.0

6 SR 36/19 - HYD

2517

56.0

6 SR 36/23 - HYD

2969

67.0

6 SR 44/3 - HYD

710

20.0

6 SR 44/4 - HYD

823

21.5

6 SR 44/5 - HYD

936

24.1

6 SR 44/6 - HYD

1049

28.0

6 SR 44/8 - HYD

1275

32.2

6 SR 44/9 - HYD

1388

35.0

6 SR 44/11 - HYD

1613

40.0

6 SR 44/13 - HYD

1839

45.0

6 SR 44/16 - HYD

2178

54.0

6 SR 44/21 - HYD

2743

63.3

219


4PD PEDROLLO 4” submersible motors

PERFORMANCE RANGE

CERTIFICATIONS

APPLICATION LIMITS

COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

•• Powers from 0.37 to 7.5 kW •• Maximum liquid temperature +35 °C •• 100 m immersion limit •• Starts/hour: 20 at regular intervals •• Minimum flow rate for motor cooling 8 cm/s •• Continuous service S1

OPTIONALS AVAILABLE ON REQUEST

ELECTRIC MOTOR

GUARANTEE

•• 2 pole electric motor, 50 Hz (n ~ 2900 1/min) •• Voltage:

– single-phase 230 V up to 2.2 kW – three-phase 400 V

•• Insulation: F class  Protection: IP 68

CONSTRUCTION AND SAFETY STANDARDS Rewindable submersible oil filled motor (oil type vegetable). Flange coupling dimensions in compliance with NEMA standards. Complete with power cable of the following length: – 1.5 m for powers from 0.37 to 2.2 kW – 2.5 m for powers from 3 to 5.5 kW – 3.5 m for power from 7.5 kW. ➠ Single-phase versions come with a capacitor included in the packaging. EN 60034-1 IEC 60034-1 CEI 2-3

220

•• Other voltages or 60 Hz frequency

1 year subject to terms and conditions


PERFORMANCE DATA Single-phase versions Rated power

Axial load

Revs

h

Weight

Starting current Rated current

Power factor

cos ϕ

μF

mm

kg

2800

3.3

0.86

20

311

6.5

P2

Capacitor (VL=450V)

230 V / 50 Hz

kW

HP

4PDm / 0.50

0.37

0.50

4PDm / 0.75

0.55

0.75

2810

3.5

0.89

25

331

7.2

4PDm / 1

0.75

1

2825

3.2

0.91

35

356

8.5

4PDm / 1.5

1.1

1.5

2840

3.2

0.93

40

386

10.5

4PDm / 2

1.5

2

2845

3.3

0.93

60

436

11.7

4PDm / 3

2.2

3

2820

3.1

0.94

75

481

15.0

N

h

2000

1/min

38

MODEL

Three-phase versions MODEL

Rated power

Axial load

Revs

N

1/min

P2 400 V / 50 Hz

kW

HP

Starting current Rated current

Power factor

h

Weight

cos ϕ

mm

kg

4PD / 0.50

0.37

0.50

2855

3.3

0.52

311

6.5

4PD / 0.75

0.55

0.75

2835

4

0.63

331

7.2

4PD / 1

0.75

1

4PD / 1.5

1.1

1.5

2000

2825

3.8

0.71

356

8.5

2780

3.5

0.79

354

10.4

4PD / 2

1.5

2

2825

4.4

0.76

428

11.1

4PD / 3

2.2

3

2810

6.5

0.73

436

11.7

4PD / 4

3

4

2810

4.7

0.78

522

15.6

4PD / 5.5

4

5.5

2820

5.1

0.77

587

18.8

4PD / 7.5

5.5

7.5

2845

5.4

0.82

687

25.4

4PD / 10

7.5

10

2835

5.3

0.3

768

29.2

2500 4500

Ø 96

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

Three-phase

230 V

400 V

240 V

415 V

4PDm / 0.50

3.6 A

4PD / 0.50

3.1 A

1.8 A

3.0 A

1.7 A

4PDm / 0.75

4.7 A

4PD / 0.75

3.5 A

2.0 A

3.3 A

1.9 A

4PDm / 1

5.9 A

4PD / 1

4.3 A

2.5 A

4.2 A

2.4 A

4PDm / 1.5

8.3 A

4PD / 1.5

5.0 A

2.9 A

5.2 A

3.0 A

4PDm / 2

10.7 A

4PD / 2

7.1 A

4.1 A

7.4 A

4.3 A

4PDm / 3

15.2 A

4PD / 3

10.6 A

6.1 A

10.2 A

5.9 A

4PD / 4

13.0 A

7.5 A

13.7 A

7.9 A

4PD / 5.5

17.0 A

9.8 A

17.8 A

10.3 A

4PD / 7.5

22.8 A

13.2 A

23.5 A

13.6 A

4PD / 10

29.2 A

16.9 A

29.9 A

17.3 A

221


4FK FRANKLIN ELECTRIC 4” submersible motors

PERFORMANCE RANGE

•• Powers from 0.37 to 7.5 kW

APPLICATION LIMITS

•• Maximum liquid temperature +35 °C •• 100 m immersion limit •• Starts/hour: 20 at regular intervals •• Minimum flow rate for motor cooling 8 cm/s •• Continuous service S1

ELECTRIC MOTOR

•• 2 pole electric motor, 50 Hz (n ~ 2900 1/min) •• Voltage:

•• ••

– single-phase 230 V fino a 2.2 kW – three-phase 400 V Insulation: B class Protection: IP 68

CONSTRUCTION AND SAFETY STANDARDS Resin encapsulated windings. Flange coupling dimensions in compliance with NEMA standards. Complete with power cable of the following length: – 1.5 m for powers from 0.37 to 3 kW – 2.5 m for powers from 4 to 7.5 kW ➠ Capacitor not included for single-phase versions. EN 60034-1 IEC 60034-1 CEI 2-3

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

222


PERFORMANCE DATA Single-phase versions Rated power

Axial load

Revs

kW

HP

4FKm / 0.50

0.37

0.50

4FKm / 0.75

0.55

0.75

4FKm / 1

0.75

1

4FKm / 1.5

1.1

1.5

4FKm / 2

1.5

2

4FKm / 3

2.2

3

N

cos ϕ

μF

mm

kg

2860

3.3

0.93

16

242

8.3

2855

3.7

0.94

20

271

9.6

2855

3.7

0.98

30

298

10.8

1/min

1500

3000

Capacitor (VL=450V)

2855

3.7

0.94

40

327

12.1

2825

3.3

0.95

50

356

13.5

2810

3.4

0.99

70

460

18

h

4000

Weight

Power factor

P2 230 V / 50 Hz

h

Starting current Rated current

38

MODEL

Three-phase versions MODEL

Rated power

Axial load

Revs

N

1/min

P2 400 V / 50 Hz

kW

4FK / 0.50

0.37

0.5

4FK / 0.75

0.55

0.75

HP

1500

Starting current Rated current

Power factor

h

Weight

cos ϕ

mm

kg

2865

4.3

0.7

223

7.3

2855

4

0.75

242

8.3

4FK / 1

0.75

1

2870

4.4

0.75

271

9.6

4FK / 1.5

1.1

1.5

2840

4.8

0.76

298

10.8

4FK / 2

1.5

2

4FK / 3

2.2

3

4FK / 4

3

4

4FK / 5.5

4

5.5

4FK / 7.5

5.5

7.5

4FK / 10

7.5

10

3000 4000

6500

2855

4.8

0.76

327

12.1

2840

4.9

0.75

356

13.5

2850

5.3

0.75

423

16

2855

5.8

0.78

583

24.1

2850

6.0

0.79

698

29.4

2820

5.5

0.79

774

33

Ø 95.5

ABSORPTION MODEL Single-phase

VOLTAGE (single-phase) 230 V

MODEL Three-phase

VOLTAGE (three-phase) 230 V

400 V

4FKm / 0.50

3.4 A

4FK / 0.50

1.9 A

1.1 A

4FKm / 0.75

4.3 A

4FK / 0.75

2.8 A

1.6 A

4FKm / 1

5.7 A

4FK / 1

3.6 A

2.1 A

4FKm / 1.5

8.6 A

4FK / 1.5

5.2 A

3.0 A

4FKm / 2

10.6 A

4FK / 2

6.9 A

4.0 A

4FKm / 3

16.0 A

4FK / 3

10.2 A

5.9 A

4FK / 4

13.5 A

7.8 A

4FK / 5.5

17.3 A

10.0 A

4FK / 7.5

23.7 A

13.7 A

4FK / 10

31.8 A

18.4 A

223


6PD 6” submersible motors

PERFORMANCE RANGE

•• Powers from 4 to 30 kW

CONSTRUCTION AND SAFETY STANDARDS Rewindable submersible oil filled motor (oil type vegetable). Flange coupling dimensions in compliance with NEMA standards.

APPLICATION LIMITS

Complete with 4 m long power cable.

•• Maximum liquid temperature +35 °C •• 100 m immersion limit •• Suitable for vertical and horizontal installations with operating

EN 60034-1 IEC 60034-1 CEI 2-3

•• Starts/hour: 20 at regular intervals •• Minimum flow rate for motor cooling 16 cm/s (0.5 m/s for 30 kW) •• Continuous service S1

CERTIFICATIONS

limits as described for the 6SR submersible pump

ELECTRIC MOTOR

•• 2 pole electric motor, 50 Hz (n ~ 2900 1/min) •• Three-phase voltage 400 V •• Insulation: F class •• Protection: IP 68

COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

OPTIONALS AVAILABLE ON REQUEST

•• Dual voltage 400/690 V (star/delta) motors from 11 kW to 30 kW •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

224


Rated power

Three-phase 400 V / 50 Hz

Axial load

Revs

N

1/min

P2

Starting current Rated current

Efficiency

Power factor

Rated torque

η

cos ϕ

Nm

Starting torque Rated torque

h

Weight

mm

kg

kW

HP

6PD / 5.5

4

5.5

2840

4.6

79%

0.77

13.5

1.8

633

34

6PD / 7.5

5.5

7.5

2850

5.1

80%

0.74

18.4

2

667

36

6PD / 10

7.5

10

2835

5.2

81%

0.80

25.3

2

698

39

6PD / 12.5

9.2

12.5

2850

5.4

82%

0.78

30.8

2.3

731

42

6PD / 15

11

15

2895

5.5

82%

0.77

36.3

2.2

826

50

6PD / 20

15

20

2875

5.4

83%

0.78

49.8

2.1

894

57

6PD / 25

18.5

25

2870

6

84%

0.78

61.6

2.4

959

65

6PD / 30

22

30

2890

5.9

85%

0.70

72.7

2.5

1116

87

6PD / 40

30

40

2850

6.2

85%

0.82

100.6

2.7

1243

91

10000

20000

h

MODEL

73

PERFORMANCE DATA

Ø 140

ABSORPTION MODEL Three-phase

VOLTAGE (three-phase) 400 V

415 V

6PD / 5.5

9.5 A

9.6 A

6PD / 7.5

13.5 A

13.2 A

6PD / 10

16.8 A

17.1 A

6PD / 12.5

20.9 A

21.5 A

6PD / 15

25.3 A

26.6 A

6PD / 20

33.4 A

34.7 A

6PD / 25

40.7 A

42.1 A

6PD / 30

53.3 A

57.6 A

6PD / 40

61.9 A

62.2 A

225


TOP MULTI® Submersible multi-impeller pumps

PERFORMANCE RANGE

•• Flow rate up to 120 l/min (7.2 m³/h) •• Head up to 42 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. As a result of their high efficiency and reliability they are suitable for use in applications such as domestic water supply from reservoirs, tanks or relatively deep wells, for drawing rain water from cisterns to water gardens or for use in irrigation systems, etc.

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 1.3 mm •• Suction down to 22 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS Complete with: – 10 m long power cable – float switch EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

226

PATENTS - TRADE MARKS - MODELS

•• Registered model TOP MULTI® n° 1334477 •• Registered Community Design n° 000885587

OPTIONALS AVAILABLE ON REQUEST

•• Pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

45

5

10

0

50 Hz  n= 2900 1/min

15

5

20

10

25

15

20

30

US g.p.m.

25

Imp g.p.m. feet 140

TOP MULTI 2

40

120

35 TOP MULTI 3 100

Head H (metres) 4

30 25

80

20 60

15 40

10 20

5 0

0

10

0

20

30

1

40

50

2

60

3

70

80

4

90

100

5

110

6

120

l/min

0

m³/h

7

Flow rate Q 4

POWER

MODEL Single-phase

kW

HP

TOP MULTI 2

0.55

0.75

TOP MULTI 3

0.55

0.75

Q = Flow rate H = Total manometric head

Q

m³/h

0

0.6

1.2

1.8

2.4

3.0

3.6

4.2

4.8

5.4

6.0

6.6

7.2

l/min

0

10

20

30

40

50

60

70

80

90

100

110

120

42

40

38

34

30

24

18

11.5

5

33

32

31

29.5

28

25.5

23

20.5

18

15

12

8

4

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

227


TOP MULTI POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

DELIVERY BODY

Glass fibre reinforced technopolymer, complete with threaded delivery port in compliance with ISO 228/1

2

PUMP BODY AND SUCTION FILTER

Glass fibre reinforced technopolymer

3

MOTOR SLEEVE

Stainless steel AISI 304

4

IMPELLERS

Noryl GFN2V

5

DIFFUSERS

Noryl GFN2V complete with anti-wear rings

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

STA-13R STA-12R SIC

Ø 13 mm Ø 12 mm

8

BEARINGS

6202 ZZ - C3 / 6201 ZZ

9

CAPACITOR

Position Motor side Pump side

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Ceramic

Graphite Silicon carbide

NBR NBR

14

Capacitance

10

(230 V or 240 V)

(110 V)

12.5 μF 450 VL

30 μF 250 VL

ELECTRIC MOTOR TOP MULTI: single-phase 230 V - 50 Hz with built-in overload protector. – Insulation: F class. – Protection: IP X8.

11

11 13

POWER CABLE

1

8

➠ 10 metre long “H07 RN-F” cable with Schuko plug

6

12

FLOAT SWITCH

10

13

HOSE CONNECTOR WITH UNION

3

Ø 35 mm hose connection 14

PIPE COUPLING

9

12

8 7

Threaded 1¼” in compliance with ISO 228/1, complete with clapet valve 2

4

5

228


DIMENSIONS AND WEIGHT Typical installation

e d

h

p (minimum)

DN

(minimum) a

MODEL

PORT

DIMENSIONS mm

N° STAGES

DN

Single-phase TOP MULTI 2

1¼"

TOP MULTI 3

3

a

h

d

e

p

178

380

22

variable

500

kg 500

9.4

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP MULTI 2

3.4 A

3.3 A

6.8 A

TOP MULTI 3

3.6 A

3.5 A

7.2 A

PALLETIZATION MODEL Single-phase

GROUPAGE n° H (mm) pumps

CONTAINER kg

n° pumps

H (mm)

kg

TOP MULTI 2

60

1370

582

80

1780

770

TOP MULTI 3

60

1370

582

80

1780

770

H

0 80

00

12

229


TOP Submersible DRAINAGE pumps ➠ for clear water

PERFORMANCE RANGE

•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 14.5 m

APPLICATION LIMITS

•• Immersion depth: •• •• •• ••

– 3 m for TOP 1-2-3 – 5 m for TOP 4-5 (with a sufficiently long power cable) Maximum liquid temperature +40 °C (Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 10 mm Suction level: – 14 mm above ground level for TOP 1-2-3 – 30 mm above ground level for TOP 4-5 Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable for TOP 1-2-3 – 10 m long power cable for TOP 4-5 – float switch EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE The TOP series is suitable for use with clear water that does not contain abrasive particles. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0011

OPTIONALS AVAILABLE ON REQUEST

•• “TOP 2-3 LA” pumps intended for use with aggressive liquids •• Special mechanical seal •• TOP 1-2-3 pumps with 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

230


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

TOP5

TOP4

Head H (metres) 4

TOP3

TOP2

TOP1

Flow rate Q 4

MODEL

POWER

m³/h

0

1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12 13.2 14.4 15.6 16.8 18.0 19.2 20.4 21.6 22.8 24

l/min

0

20

0.33

7

6

5.5 4.5

4

0.50

9

8

7.5 6.5

6

Single-phase

kW

HP

TOP 1

0.25

TOP 2

0.37

TOP 3

0.55

0.75

TOP 4

0.75

1

TOP 5

0.92

1.25

Q = Flow rate H = Total manometric head

Q

H metres 10.5 10

40

9

60

8.8

80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 3

2.5 1.5

5.5 4.5

4

1 3

2.5 1.8

1

8

7.5 6.5

6

5.5 4.8

4

3.5 2.5

2

12.6 12 11.5 10.7 10

9.3 8.7

8

7.3 6.7

6

5.3 4.7

4

14.5 14 13.5 12.7 12.1 11.5 10.8 10.2 9.6 8.9 8.3 7.7

3.3 2.7

2

7.1 6.4 5.8 5.2 4.5 3.9 3.3 2.6

2

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

231


TOP 1-2-3 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Technopolymer

2

SUCTION FILTER

Technopolymer

3

SUCTION PLATE

Stainless steel AISI 304

4

DIFFUSER

Technopolymer

5

IMPELLER

Noryl GFN2V

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Pump

Seal

Shaft

Model

Model

Diameter

TOP 1-2-3 TOP 2-3 LA

AR-12R AR-12R LA

Ø 12 mm Ø 12 mm

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Ceramic

Graphite Graphite

NBR NBR

14

13

14

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

TOP 1 TOP 2 TOP 3

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL

16 μF 250 VL 16 μF 250 VL 16 μF 250 VL

1

ELECTRIC MOTOR

12

– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

11

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

15

15

HOSE CONNECTOR WITH UNION Ø 25 mm hose connection for TOP 1 Ø 35 mm for TOP 2-3

6 13 11 7 10

8 4

232

5

9

2

3


DIMENSIONS AND WEIGHT Typical installation

d

e

p (minimum)

h

h1

DN

(minimum)

a

MODEL Single-phase

PORT

DIMENSIONS mm

DN

a

TOP 1 TOP 2

1¼”

152

TOP 3

h

h1

257

237

287

267

d

e

kg

p

4.5 14

variable

350

350

5.2 6.6

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP 1

1.4 A

1.3 A

3.0 A

TOP 2

2.0 A

2.0 A

5.3 A

TOP 3

3.2 A

3.2 A

7.9 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

TOP 1

96

TOP 2 TOP 3

Single-phase

CONTAINER kg

n° pumps

H (mm)

kg

1260

444

168

2100

765

96

1260

515

168

2100

888

96

1360

653

144

1970

971

H

0 80

00

12

233


TOP 4-5 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Technopolymer

2

SUCTION FILTER

Technopolymer

3

SUCTION PLATE

Stainless steel AISI 304

4

DIFFUSER

Technopolymer

5

IMPELLER

Ryton

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

10

LIP SEAL

Ø 16 x Ø 24 x H 5 mm

11

BEARINGS

6203 ZZ / 6203 ZZ

12

CAPACITOR Pump

13

15

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

TOP 4 TOP 5

16 μF 450 VL 20 μF 450 VL

30 μF 250 VL 30 μF 250 VL

– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8 14

1 12

11

HOSE CONNECTOR WITH UNION Hose connection Ø 41 mm

16

16

HANDLE ASSEMBLY (resin sealed) Complete with: – 10 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

15

14

ELECTRIC MOTOR

PIPE COUPLING In technopolymer with 1½" thread and clapet valve

6 13 11

7 10

8 4

234

5

9

2

3


DIMENSIONS AND WEIGHT Typical installation

d

a

MODEL Single-phase TOP 4 TOP 5

e

p (minimum)

h

h1

DN

PORT

(minimum)

DIMENSIONS mm

DN

a

h

h1

d

e

p

1½”

204

334

310

30

variable

450

kg 450

10.1 11.1

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP 4

4.8 A

4.8 A

9.6 A

TOP 5

6.5 A

6.5 A

13.0 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

TOP 4

54

TOP 5

54

Single-phase

CONTAINER kg

n° pumps

H (mm)

1295

563

90

2065

928

1295

617

90

2065

1016

kg H

0 80

00

12

235


TOP-GM Submersible DRAINAGE pumps ➠ for clear water

Version with vertical magnetic float switch

PERFORMANCE RANGE

•• Flow rate up to 260 l/min (15.6 m3/h) •• Head up to 10.5 m

APPLICATION LIMITS

•• 3 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 10 mm •• Suction down to 14 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable – vertical magnetic float switch EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

236

INSTALLATION AND USE The TOP-GM series is suitable for use with clear water that does not contain abrasive particles and comes complete with a vertical float switch meaning that the pumps can be used in particularly small spaces. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0011

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Pumps with a 10 m long power cable ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

TOP3-GM

Head H (metres) 4

TOP2-GM

TOP1-GM

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

TOP 1-GM

0.25

0.33

TOP 2-GM

0.37

0.50

TOP 3-GM

0.55

0.75

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

10.8

12

13.2

14.4

15.6

l/min

0

20

40

60

80

100

120

140

160

180

200

220

240

260

7

6

5.5

4.5

4

3

2.5

1.8

1

9

8

7.5

6.5

6

5.5

4.5

4

3

2.5

1.8

1

10.5

10

9

8.8

8

7.5

6.5

6

5.5

4.8

4

3.5

2.5

2

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

237


TOP-GM POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Technopolymer

2

SUCTION FILTER

Technopolymer

3

SUCTION PLATE

Stainless steel AISI 304

4

DIFFUSER

Technopolymer

5

IMPELLER

Noryl GFN2V

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR

13

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

TOP 1-GM TOP 2-GM TOP 3-GM

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL

16 μF 250 VL 16 μF 250 VL 16 μF 250 VL

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

15

15

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

14

14

HOSE CONNECTOR WITH UNION Ø 25 mm hose connection for TOP 1 Ø 35 mm for TOP 2-3

1 12 11

6 13 11 7 10

8 4

238

5

9

2

3


DIMENSIONS AND WEIGHT Typical installation

p (minimum) a (minimum)

b

MODEL Single-phase

PORT

DIMENSIONS mm

DN

a

b

1¼”

152

200

TOP 1-GM TOP 2-GM

ee

g

d

h1

h

DN

TOP 3-GM

h

h1

257

237

287

267

d 14

e

g

140

35

170

40

kg

p

4.6 350

220

5.3 6.7

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP 1-GM

1.4 A

1.3 A

3.0 A

TOP 2-GM

2.0 A

2.0 A

5.3 A

TOP 3-GM

3.2 A

3.2 A

7.9 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER

n° pumps

H (mm)

kg

n° pumps

H (mm)

kg

TOP 1-GM

96

1260

459

168

2100

790

TOP 2-GM

96

1260

526

168

2100

910

TOP 3-GM

96

1500

660

144

2180

982

Single-phase

H

0 80

00

12

239


TOP-FLOOR Submersible DRAINAGE pumps ➠ for clear water

PERFORMANCE RANGE

•• Flow rate up to 160 l/min (9.6 m3/h) •• Head up to 9 m

APPLICATION LIMITS

•• 3 m maximum immersion depth

INSTALLATION AND USE The TOP-FLOOR series is suitable for use with clear water that does not contain abrasive particles. As a result of their ability to drain water to a level of 2 millimetres above ground level, they are suitable for use in domestic emergencies where a small area must be drained to the lowest level possible.

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• •• ••

(Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 2 mm Suction down to 2 mm above ground level Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0011

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with float switch •• Special mechanical seal •• Pumps with a 10 m long power cable

Complete with 5 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

240

••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

9

10

50 Hz  n= 2900 1/min

20

0

30

10

US g.p.m.

40

20

Imp g.p.m.

30

feet

TOP2-FLOOR

8

25

Head H (metres) 4

7 TOP1-FLOOR

6

20

5 15

4 10

3 2

5

1 0

0 0

20

40

1

60

2

3

80 4

100 5

120

6

7

140 8

160

l/min

9

10

0

m³/h

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

TOP1-FLOOR

0.25

0.33

TOP2-FLOOR

0.37

0.50

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

l/min

0

20

40

60

80

100

120

140

160

7

6

5

4

3

2

1

9

8

7

6

5

4

3

2

1

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

241


TOP-FLOOR POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Technopolymer

2

SUCTION FILTER

Technopolymer

3

SUCTION PLATE

Stainless steel AISI 304

4

DIFFUSER

Technopolymer

5

IMPELLER

Noryl GFN2V

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR Pump

13

14

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

TOP1-FLOOR TOP2-FLOOR

10 μF 450 VL 10 μF 450 VL

16 μF 250 VL 16 μF 250 VL

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

14

1 12

11

HANDLE ASSEMBLY (resin sealed) Complete with 5 metre long “H07 RN-F” power cable with Schuko plug

15

15

6

HOSE CONNECTOR WITH UNION

13

Ø 25 mm hose connection for TOP1 - FLOOR Ø 35 mm for TOP2 - FLOOR

11 7 10

8 4

242

5

9

2

3


DIMENSIONS AND WEIGHT

Typical installation

Draining down to 2 mm

h

h1

DN

a

MODEL

PORT

TOP1-FLOOR TOP2 -FLOOR

DIMENSIONS mm

DN

a

h

h1

Minimum drying level

1¼”

152

257

237

2 mm

Single-phase

kg 4.3 5.0

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP1-FLOOR

1.4 A

1.3 A

3.0 A

TOP2-FLOOR

2.0 A

2.0 A

5.3 A

PALLETIZATION MODEL

GROUPAGE

Single-phase

n° pumps

H (mm)

TOP1-FLOOR

96

TOP2 -FLOOR

96

CONTAINER kg

n° pumps

H (mm)

kg

1260

430

168

2100

739

1260

500

168

2100

862

H

0

80

00

12

243


TOP-VORTEX Submersible pump ➠ for dirty water

PERFORMANCE RANGE

•• Flow rate up to 180 l/min (10.8 m3/h) •• Head up to 7 m

APPLICATION LIMITS

•• 3 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• •• ••

(Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 20 mm Suction down to 25 mm above ground level Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable – float switch EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

244

INSTALLATION AND USE The TOP-VORTEX pump is suitable for use with dirty water that is not chemically aggressive towards the materials from which the pump is made. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as clearing dirty water, emptying tanks, discharging domestic waste water, and for emptying collection traps containing suspended solids up to a maximum of Ø 20 mm.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0011

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

Head H (metres) 4

TOP–VORTEX

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

TOP-VORTEX

0.37

0.50

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

10.8

l/min

0

20

40

60

80

100

120

140

160

180

7

6.5

6

5.4

4.8

4.2

3.5

3

2.5

1.5

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

245


TOP-VORTEX POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Technopolymer

2

SUCTION FILTER

Technopolymer

3

SUCTION PLATE

Technopolymer

4

DIFFUSER

Technopolymer

5

IMPELLER

Technopolymer VORTEX type

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR

14

Capacitance

13

(230 V or 240 V)

(110 V)

10 μF 450 VL

16 μF 250 VL

15

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

1

12 11

14

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

15

6 13

HOSE CONNECTOR WITH UNION

11

Hose connection Ø 35 mm

7 10

8

4

5

246

9

2

3


DIMENSIONS AND WEIGHT

Typical installation

a

MODEL

e d

p (minimum)

h

h1

DN

PORT

(minimum)

DIMENSIONS mm

Single-phase

DN

a

h

h1

d

e

p

TOP-VORTEX

1¼”

152

288

268

25

variable

350

kg 350

5.1

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP-VORTEX

2.0 A

2.0 A

5.3 A

PALLETIZATION MODEL

GROUPAGE

Single-phase

n° pumps

H (mm)

TOP-VORTEX

96

1360

CONTAINER kg

n° pumps

H (mm)

kg

508

144

1970

753

H

0 80

00

12

247


TOP-VORTEX/GM Submersible pump ➠ for dirty water

Version with vertical magnetic float switch

PERFORMANCE RANGE

•• Flow rate up to 180 l/min (10.8 m3/h) •• Head up to 7 m

APPLICATION LIMITS

•• 3 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 20 mm •• Suction down to 25 mm above ground level •• Continuous service S1

INSTALLATION AND USE The TOP-VORTEX/GM pump is suitable for use with dirty water and comes complete with a vertical float switch meaning that the pump can be used in particularly small spaces. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in applications such as clearing dirty water, emptying tanks, discharging domestic waste water, and for emptying small collection traps containing suspended solids up to a maximum of Ø 20 mm.

PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS

•• Registered Community Design n° 342159-0011

Complete with: – 5 m long power cable – vertical magnetic float switch

OPTIONALS AVAILABLE ON REQUEST

EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

248

•• Special mechanical seal •• Pumps with a 10 m long power cable ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

Head H (metres) 4

TOP-VORTEX/GM

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

TOP-VORTEX/GM

0.37

0.50

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

10.8

l/min

0

20

40

60

80

100

120

140

160

180

7

6.5

6

5.4

4.8

4.2

3.5

3

2.5

1.5

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

249


TOP-VORTEX/GM POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Technopolymer

2

SUCTION FILTER

Technopolymer

3

SUCTION PLATE

Technopolymer

4

DIFFUSER

Technopolymer

5

IMPELLER

Technopolymer VORTEX type

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR

14 15

Capacitance

13

(230 V or 240 V)

(110 V)

10 μF 450 VL

16 μF 250 VL

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

14

15

1 12

11

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

13

HOSE CONNECTOR WITH UNION

11

Hose connection Ø 35 mm

6

7 10

4 8

5

250

9

2

3


DIMENSIONS AND WEIGHT

Typical installation

e

d

g

p (minimum)

h1

h

DN

a b

MODEL

(minimum)

PORT

DIMENSIONS mm

Single-phase

DN

a

b

h

h1

d

e

g

p

TOP-VORTEX/GM

1¼”

152

200

288

268

25

170

40

350

kg 220

5.2

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

TOP-VORTEX/GM

2.0 A

2.0 A

5.3 A

PALLETIZATION MODEL Single-phase TOP-VORTEX/GM

GROUPAGE n° pumps

H (mm)

96

1360

CONTAINER kg

n° pumps

H (mm)

kg

520

144

1970

771

H

0 80

00

12

251


RX Submersible DRAINAGE pumps ➠ for clear water

PERFORMANCE RANGE

•• Flow rate up to 300 l/min (18 m3/h) •• Head up to 20 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +50 °C •• •• ••

(Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Passage of suspended solids up to Ø 10 mm Suction level: – 14 mm above ground level for RX 1-2-3 – 25 mm above ground level for RX 4-5 Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable for RX1-2-3 – 10 m long power cable for RX 4-5 – float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

252

INSTALLATION AND USE The RX series pumps are suitable for use with clear water that does not contain abrasive particles. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in fixed installations and applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0013 (RX 1-2-3)

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• RX 1-2-3 pumps with a 10 m long power cable. •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

22

10

0

20

30

10

50 Hz  n= 2900 1/min 40

20

50

30

60

40

US g.p.m.

70

50

Imp g.p.m.

60

feet

20

RX5 60

18 16

50

Head H (metres) 4

RX4

14 40

12

RX3

10

RX2

30

8 RX1

6

20

4 10

2 0

0

20

0

40 2

60

80

100

4

MODEL

kW

140

6

POWER

Single-phase Three-phase

120

HP

Q

8

160

180

200

10

220

12

Flow rate Q 4

240

260

14

280 16

300 l/min 18

m³/h

m³/h

0

1.2

3.6

6.0

8.4

9.6

12.0

13.2

15.6

18.0

l/min

0

20

60

100

140

160

200

220

260

300

2.5

2

RXm 1

0.25

0.33

7.5

6.5

5

3.5

2

1

RXm 2

0.37

0.50

10

9.5

8

6.5

5

4.5

RXm 3

0.55

0.75

12

11.5

9.5

8

6.5

5.5

3.5

3

RXm 4

RX 4

0.75

1

16

15

13

11.5

9.5

8.5

6.5

5.5

4

RXm 5

RX 5

1.1

1.5

20

19.5

17.5

15.5

13.5

12.5

10

9

7

Q = Flow rate H = Total manometric head

0

H metres

5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

253


RX 1-2-3 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Stainless steel AISI 304

5

MOTOR CASING

Stainless steel AISI 304

6

MOTOR CASING PLATE

Stainless steel AISI 304

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

9

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

10

BEARINGS

6201 ZZ / 6201 ZZ

11

CAPACITOR Pump

12

13

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

RXm 1 RXm 2 RXm 3

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL

16 μF 250 VL 16 μF 250 VL 16 μF 250 VL

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

13

1 11

10

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

5 12 10 6 9

7 4

254

8

2

3


DIMENSIONS AND WEIGHT

Typical installation

d

e

p (minimum)

h

h1

DN

(minimum)

a

MODEL Single-phase

PORT

DIMENSIONS mm

DN

a

1¼”

147

RXm 1 RXm 2 RXm 3

h

h1

255

247

285

277

d

e

p

14

variable

350

kg 4.7 350

5.8 7.4

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

RXm 1

1.4 A

1.3 A

3.0 A

RXm 2

2.0 A

2.0 A

5.3 A

RXm 3

3.6 A

3.6 A

7.5 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

RXm 1

96

RXm 2 RXm 3

Single-phase

CONTAINER kg

n° pumps

H (mm)

kg

1320

467

162

2131

776

96

1320

573

162

2131

955

96

1360

727

144

1970

1083

H

0 80

00

12

255


RX 4-5 POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Stainless steel AISI 304

5

MOTOR CASING

Stainless steel AISI 304

6

MOTOR CASING PLATE

Stainless steel AISI 304

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE MECHANICAL SEAL SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14D SIC

Ø 14 mm

9

BEARINGS

10

CAPACITOR Pump

11

Materials Stationary ring

Rotational ring

Silicon carbide Silicon carbide

13

NBR

6203 ZZ / 6203 ZZ 12

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

RXm 4 RXm 5

20 μF 450 VL 25 μF 450 VL

30 μF 250 VL –

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

12

Elastomer

POWER CABLE

1 10

9 7

5

10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

11

FLOAT SWITCH

9

13

(only for single-phase versions) 6

8

4

256

2

3


DIMENSIONS AND WEIGHT

Typical installation

d

e

p (minimum)

h

h1

DN

a

MODEL Single-phase

PORT

Three-phase

RXm 4

RX 4

RXm 5

RX 5

(minimum)

DIMENSIONS mm

kg

DN

a

h

h1

d

e

p

1½"

220

367

336

25

variable

500

1~ 500

3~

12.7

11.9

13.7

12.7

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

RXm 4

5.4 A

5.4 A

11.0 A

RX 4

3.6 A

2.1 A

3.6 A

2.1 A

RX 5

6.0 A

3.5 A

6.0 A

3.5 A

7.5 A

RXm 5

7.5 A

415 V

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

kg

3~

n° pumps

H (mm)

1~

3~

Single-phase

Three-phase

RXm 4

RX 4

45

1388

589

553

60

1804

779

731

RXm 5

RX 5

45

1388

634

589

60

1804

839

779

H

0

80

00

12

257


RX-GM Submersible DRAINAGE pumps ➠ for clear water

Version with vertical magnetic float switch

PERFORMANCE RANGE

•• Flow rate up to 220 l/min (13.2 m3/h) •• Head up to 12 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 10 mm •• Suction down to 14 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable – vertical magnetic float switch EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

258

INSTALLATION AND USE The RX-GM series is suitable for use with clear water that does not contain abrasive particles and comes complete with a vertical float switch meaning that the pumps can be used in particularly small spaces. As a result of the design solutions that have been adopted, such as the complete cooling of the motor and the shaft with double seal, these pumps are easy to use and reliable. They are suitable for use in fixed installations and applications such as draining small flooded areas (rooms, cellars, garages) in the event of an emergency, for the disposal of waste water in the home (from dishwashers, washing machines) and for emptying drainage traps.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0013

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Pumps with a 10 m long power cable. ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

13

10

0

20

50 Hz  n= 2900 1/min 30

10

40

20

50

30

US g.p.m.

40

Imp g.p.m. feet 40

12

RX3-GM

11

35

10

RX2-GM 30

Head H (metres) 4

9 8

25

7

RX1-GM 20

6 5

15

4 10

3 2

5

1 0

0 0

20 1

40

60

2

3

80 4

100 5

6

120 7

140 8

160 9

180 10

11

200 12

220 13

l/min 0

0 1

m³/h

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

RXm 1-GM

0.25

0.33

RXm 2-GM

0.37

0.50

RXm 3-GM

0.55

0.75

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.2

3.6

6.0

8.4

9.6

12.0

13.2

l/min

0

20

60

100

140

160

200

220

7.5

6.5

5

3.5

2

1

10

9.5

8

6.5

5

4.5

2.5

2

12

11.5

9.5

8

6.5

5.5

3.5

3

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

259


RX-GM POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Stainless steel AISI 304

5

MOTOR CASING

Stainless steel AISI 304

6

MOTOR CASING PLATE

Stainless steel AISI 304

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

9

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

10

BEARINGS

6201 ZZ / 6201 ZZ

11

CAPACITOR

12

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

RXm 1-GM RXm 2-GM RXm 3-GM

10 μF 450 VL 10 μF 450 VL 14 μF 450 VL

16 μF 250 VL 16 μF 250 VL 16 μF 250 VL

13

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class – Protection: IP X8

13

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

1 11

10

5 12 10 6 9

7 4

260

8

2

3


DIMENSIONS AND WEIGHT

Typical installation

a

MODEL Single-phase

(minimum)

PORT

DIMENSIONS mm

DN

a

1¼”

147

RXm 1-GM RXm 2-GM

e

g

d

h1

h

p (minimum)

DN

RXm 3-GM

h

h1

270

247

300

277

d 14

e

g

145

40

175

45

kg

p

4.8 350

240

5.9 7.5

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

RXm 1-GM

1.4 A

1.3 A

3.0 A

RXm 2-GM

2.0 A

2.0 A

5.3 A

RXm 3-GM

3.6 A

3.6 A

7.5 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

RXm 1-GM

60

RXm 2-GM RXm 3-GM

Single-phase

CONTAINER kg

n° pumps

H (mm)

kg

1409

312

90

2054

456

60

1409

378

90

2054

555

60

1489

474

75

1844

587

H

0 80

00

12

261


RX 2-3-4-5 "VORTEX" Submersible pumps ➠ for dirty water

PERFORMANCE RANGE

•• Flow rate up to 380 l/min (22.8 m3/h) •• Head up to 13 m

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

APPLICATION LIMITS

•• 10 m maximum immersion depth •• •• •• ••

(with a sufficiently long power cable) Maximum liquid temperature +50 °C (Maximum liquid temperature +90 °C for a maximum of 3 minutes intermittent service) Solids passage: – up to Ø 20 mm for RX 2/20, RX 3/20 – up to Ø 40 mm for RX 4/40, RX 5/40 Suction level: – 25 mm above ground level for RX 2/20, RX 3/20 – 50 mm above ground level for RX 4/40, RX 5/40 Continuous service S1

CONSTRUCTION AND SAFETY STANDARDS Complete with: – 5 m long power cable for RX 2/20, RX 3/20 – 10 m long power cable for RX 4/40, RX 5/40 – float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150

262

EN 60034-1 IEC 60034-1 CEI 2-3

INSTALLATION AND USE The RX-VORTEX series pumps are suitable for use with dirty water. The design solutions that have been adopted, such as the complete cooling of the motor, guarantee the reliability of the pump. They are suitable for use in domestic applications such as for discharging dirty water containing suspended solids.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0013

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal •• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

15

10

0

20

30

10

40

20

50 Hz  n= 2900 1/min 50

30

60

40

70

80

50

US g.p.m.

90

60

70

80

Imp g.p.m. feet

14

50

13 RX5/40 40

12

Head H (metres) 4

11

35

10 RX4/40 30

9 8

RX3/20 25

7 RX2/20 20

6 5

15

4 10

3 2

5

1 0

0

20

0

40

60

2

80 4

100

120

6

140

160

8

180

10

200

220

12

240

260

14

280

300

16

320

18

340 20

360

380 l/min

0

m³/h

22

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase

kW

HP

Q

m³/h

0

1.2

2.4

3.6

4.8

6

7.2

8.4

9.6

10.8

13.2

16.8

20.4

22.8

l/min

0

20

40

60

80

100

120

140

160

180

220

280

340

380

3

2

RXm 2/20

0.37

0.50

7

6.5

6

5.4

4.8

4.3

3.7

3.1

2.5

2

RXm 3/20

0.55

0.75

9

8

7.5

6.5

6

5.5

4.7

4.2

3.5

3

RXm 4/40

RX 4/40

0.75

1

10

9.5

8.7

8.5

7.7

7

6.5

6

5.5

4.7

3.7

2

RXm 5/40

RX 5/40

1.1

1.5

13

12.5

12

11.5

10.7

10

9.5

9

8.3

7.7

6.5

5

Q = Flow rate H = Total manometric head

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

263


RX 2-3 "VORTEX" POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

DIFFUSER

Technopolymer

5

IMPELLER

Stainless steel AISI 304 VORTEX type

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R SIC

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR Pump

13

14

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

RXm 2/20 RXm 3/20

10 μF 450 VL 14 μF 450 VL

16 μF 250 VL 16 μF 250 VL

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class. – Protection: IP X8.

14

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

1 12

11 6 7 13 11 10

9 4 8

5

264

2

3


DIMENSIONS AND WEIGHT

Typical installation

d

e

p (minimum)

h

h1

DN

a

MODEL Single-phase RXm 2/20 RXm 3/20

(minimum)

PORT

DIMENSIONS mm

DN

a

1¼”

147

h

h1

290

278

320

308

d

e

p

25

variable

350

kg 350

6.1 7.85

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

RXm 2/20

2.6 A

2.6 A

6.5 A

RXm 3/20

3.2 A

3.2 A

7.5 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

RXm 2/20

96

RXm 3/20

60

Single-phase

CONTAINER kg

n° pumps

H (mm)

kg

1500

607

144

2180

902

1310

488

100

2090

802

H

0

80

00

12

265


RX 4-5 "VORTEX" POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Stainless steel AISI 304 VORTEX type

5

MOTOR CASING

Stainless steel AISI 304

6

MOTOR CASING PLATE

Stainless steel AISI 304

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE MECHANICAL SEAL SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14D SIC

Ø 14 mm

9

BEARINGS

10

CAPACITOR

11

Materials Stationary ring

Rotational ring

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

RXm 4/40 RXm 5/40

20 μF 450 VL 25 μF 450 VL

30 μF 250 VL –

ELECTRIC MOTOR

12

10 1 7 9

5

POWER CABLE 10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

13

NBR

6203 ZZ / 6203 ZZ

– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8 12

Elastomer

Silicon carbide Silicon carbide

FLOAT SWITCH (only for single-phase versions)

13

11 9 6

8

4

266

2

3


DIMENSIONS AND WEIGHT Typical installation

e

p (minimum)

h

h1

DN

MODEL

d

a

PORT

Single-phase

Three-phase

RXm 4/40

RX 4/40

RXm 5/40

RX 5/40

(minimum)

DIMENSIONS mm

DN

a

1½"

h

220

h1

430

d

400

kg e

50

variable

p 500

500

1~

3~

13.0

12.2

14.0

13.0

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

VOLTAGE (three-phase)

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

RXm 4/40

5.2 A

5.2 A

10.5 A

RX 4/40

3.6 A

2.1 A

3.6 A

2.1A

RXm 5/40

6.5 A

6.5 A

RX 5/40

5.4 A

3.1 A

5.4 A

3.1 A

PALLETIZATION MODEL

GROUPAGE n° H pumps (mm)

Single-phase

Three-phase

RXm 4/40

RX 4/40

45

RXm 5/40

RX 5/40

45

CONTAINER kg

n° H pumps (mm)

1~

3~

1574

602

566

60

1574

647

602

60

kg 1~

3~

2052

797

749

2052

857

797

H

0

80

00

12

267


RX-GM "VORTEX" Submersible pumps ➠ for dirty water

Version with vertical magnetic float switch

PERFORMANCE RANGE

•• Flow rate up to 180 l/min (10.8 m3/h) •• Head up to 9 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage up to Ø 20 mm •• Suction down to 25 mm above ground level •• Continuous service S1 CONSTRUCTION AND SAFETY STANDARDS

INSTALLATION AND USE The RX-VORTEX/GM series pumps are suitable for use with dirty water that does not contain abrasive particles and comes complete with a vertical float switch meaning that the pumps can be used in particularly small spaces. The design solutions that have been adopted, such as the complete cooling of the motor, guarantee the reliability of the pump. They are suitable for use in domestic applications such as for discharging dirty water containing suspended solids.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0013

OPTIONALS AVAILABLE ON REQUEST

Complete with: – 5 m long power cable – vertical magnetic float switch

•• Special mechanical seal •• Pumps with a 10 m long power cable

EN 60335-1 IEC 60335-1 CEI 61-150

••

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

268

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 0

9

10

50 Hz  n= 2900 1/min

20

0

30

10

40

20

US g.p.m.

30

40

Imp g.p.m. feet

RX3/20-GM

8

25

7

Head H (metres) 4

RX2/20-GM 20

6 5

15

4 10

3 2

5

1 0

0 0

20 1

40 2

60 3

80 4

100 5

120

6

7

140

160

8

9

180 10

l/min

11

0

m³/h

Flow rate Q 4

MODEL

POWER

Single-phase

kW

HP

RXm 2/20-GM

0.37

0.50

RXm 3/20-GM

0.55

0.75

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.2

2.4

3.6

4.8

6

7.2

8.4

9.6

10.8

l/min

0

20

40

60

80

100

120

140

160

180

7

6.5

6

5.4

4.8

4.3

3.7

3.1

2.5

2

9

8

7.5

6.5

6

5.5

4.7

4.2

3.5

3

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

269


RX-GM "VORTEX" POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

DIFFUSER

Technopolymer

5

IMPELLER

Stainless steel AISI 304 VORTEX type

6

MOTOR CASING

Stainless steel AISI 304

7

MOTOR CASING PLATE

Stainless steel AISI 304

8

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

9

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

AR-12R SIC

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

10

LIP SEAL

Ø 12 x Ø 19 x H 5 mm

11

BEARINGS

6201 ZZ / 6201 ZZ

12

CAPACITOR Pump

13

14

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

RXm 2/20-GM RXm 3/20-GM

10 μF 450 VL 14 μF 450 VL

16 μF 250 VL 16 μF 250 VL

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Insulation: F class. – Protection: IP X8.

14

HANDLE ASSEMBLY (resin sealed) Complete with: – 5 metre long “H07 RN-F” power cable with Schuko plug – Float switch.

1 12

11 6 13 7

11 10

9 4 8

5

270

2

3


DIMENSIONS AND WEIGHT

Typical installation

a

MODEL Single-phase RXm 2/20-GM RXm 3/20-GM

e

g

d

h1

h

p (minimum)

DN

(minimum)

PORT

DIMENSIONS mm

DN

a

1¼”

147

h

h1

305

278

335

308

d 25

e

d

180

50

210

80

kg

p 350

240

6.2 8.0

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

RXm 2/20-GM

2.6 A

2.6 A

6.5 A

RXm 3/20-GM

3.2 A

3.2 A

7.5 A

PALLETIZATION MODEL

GROUPAGE

Single-phase

n° pumps

H (mm)

RXm 2/20-GM

60

RXm 3/20-GM

60

CONTAINER kg

n° pumps

H (mm)

kg

1489

396

75

1844

489

1696

504

75

2084

624

H

0

80

00

12

271


ZX

"VORTEX"

Submersible pumps ➠ for very dirty water

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

ZX series pumps are suitable for draining waste water in domestic applications and for pumping dirty water containing suspended solids up to Ø 40 mm. They distinguish themselves for the ease with which they are installed and their reliability under automatic operating conditions in fixed installations.

•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 11 m •• 5 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 40 mm •• Suction down to 50 mm above ground level •• 240 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 5 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0015

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal. •• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

272

1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

ZXm1A

Head H (metres) 4

ZXm1B

Flow rate Q 4

MODEL Single-phase

POWER kW

HP

ZXm 1B/40

0.50

0.70

ZXm 1A/40

0.60

0.85

Q = Flow rate H = Total manometric head

Q

m³/h

0

1.5

3.0

4.5

6.0

9.0

12.0

15.0

18.0

21.0

24.0

l/min

0

25

50

75

100

150

200

250

300

350

400

9

8.5

8.3

8

7.5

6.5

5.2

4

2.5

1

11

10.5

10

9.5

9.2

8.2

7

5.7

4.3

2.8

H metres

1.5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

273


ZX

"VORTEX"

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Technopolymer VORTEX type

4

MOTOR SLEEVE

Stainless steel AISI 304

5

MOTOR CASING

Steel

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

8

LIP SEAL

Ø 12 x Ø 22 x H 6 mm

9

BEARINGS

6201 ZZ / 6201 ZZ

10

CAPACITOR Pump

11

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

ZXm 1B/40 ZXm 1A/40

12.5 μF 450 VL 16 μF 450 VL

30 μF 250 VL 30 μF 250 VL

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8.

12

12

POWER CABLE

10

5 metre long “H07 RN-F” cable with Schuko plug 13

14

9

FLOAT SWITCH (only for single-phase versions)

5

HOSE CONNECTION

4

Ø 50 mm 11

6

9 8 7

14 13 1 2

274

3


DIMENSIONS AND WEIGHT Typical installation

DN

e

h

p (minimum)

a

d

h1

c

(minimum)

b

MODEL Single-phase ZXm 1B/40 ZXm 1A/40

PORT

DIMENSIONS mm

solids passage

DN 1½”

a

Ø 40 mm

75

b 87

c 130

h 378

h1 82

d

kg e

50

1~

p

variable

450

450

11.5 11.7

ABSORPTION MODEL Single-phase

VOLTAGE (single-phase) 230 V

240 V

110 V

ZXm 1B/40

3.3 A

3.3 A

7.0 A

ZXm 1A/40

4.5 A

4.5 A

9.0 A

PALLETIZATION MODEL Single-phase

GROUPAGE n° pumps

CONTAINER

H (mm)

kg

n° pumps

H (mm)

kg

ZXm 1B/40

60

1460

709

80

1900

940

ZXm 1A/40

60

1460

721

80

1900

956

H

0

80

00

12

275


ZD Submersible drainage pumps ➠ for clear water

PERFORMANCE RANGE

•• Flow rate up to 300 l/min (18 m3/h) •• Head up to 14 m

APPLICATION LIMITS

•• 5 m maximum immersion depth

INSTALLATION AND USE Designed to pump clear or slightly dirty water, these pumps are suitable for use in domestic applications and in particular for draining flooded areas such as cellars or for emptying tanks and reservoirs; they distinguish themselves for the ease with which they are installed and their reliability under automatic operating conditions in fixed installations.

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 10 mm •• Suction down to 21 mm above ground level •• 180 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 5 m long power cable EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

276

OPTIONALS AVAILABLE ON REQUEST

•• Special mechanical seal. •• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 10

0

15

20

30

10

0

50 Hz  n= 2900 1/min 40

20

50

30

60

40

70

50

US g.p.m. 60

Imp. g.p.m.

feet

14 ZDm1AR-E

45

13 40

12

Head H (metres) 4

11 ZDm1A-E

35

10 30

9 ZDm1B-E

8

25

7 20

6 5

15

4 10

3 2

5

1 0

0

25

50

75

MODEL

125

5

0

POWER kW

HP

ZDm 1B-E

0.37

0.50

ZDm 1A-E

0.50

0.70

ZDm 1AR-E

0.60

0.85

Single-phase

100

Q = Flow rate H = Total manometric head

Q

150

175

200

225

250

10

275

300

m3/h

15

Flow rate Q 4

0

l/min

m³/h

0

1.5

3.0

4.5

6.0

7.5

9.0

10.5

12.0

13.5

15.0

16.5

18.0

l/min

0

25

50

75

100

125

150

175

200

225

250

275

300

8.5

8

7.5

6.5

5.5

4.8

3.5

2.5

1

11

10.5

10

9

8.5

7.5

6.5

5.5

4

2.5

1.5

14

13.5

13

12.2

11.5

10.5

9.5

8.3

7

5.7

4.5

3.2

2

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

277


ZD POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Noryl GFN2V open type

5

MOTOR SLEEVE

Stainless steel AISI 304

6

MOTOR CASING

Steel

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE SEAL Seal

Shaft

Model

Diameter

AR-12R

Ø 12 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Graphite

NBR

9

LIP SEAL

Ø 12 x Ø 22 x H 6 mm

10

BEARINGS

6201 ZZ / 6201 ZZ

11

CAPACITOR Pump

12

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

ZDm 1B-E ZDm 1A-E ZDm 1AR-E

10 μF 450 VL 12.5 μF 450 VL 16 μF 450 VL

16 μF 250 VL 30 μF 250 VL 30 μF 250 VL 13

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding. – Insulation: F class. – Protection: IP X8.

13

11

POWER CABLE 10

5 metre long “H07 RN-F” cable with Schuko plug 14

6

FLOAT SWITCH (only for single-phase versions)

5 14 12 10 9

7

1

278

2

8

4

3


DIMENSIONS AND WEIGHT

Typical installation

d

h1

DN

e

h

p (minimum)

a

b

MODEL Single-phase

(minimum)

c

PORT

DIMENSIONS mm

DN

a

b

c

h

h1

d

e

kg

p

10.9

ZDm 1B-E ZDm 1A-E

1½”

110

81

142

316

77

21

variable

450

450

11.5 11.8

ZDm 1AR-E

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

110 V

ZDm 1B-E

2.5 A

2.5 A

5.2 A

ZDm 1A-E

3.3 A

3.3 A

7.0 A

ZDm 1AR-E

4.4 A

4.4 A

9.0 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

ZDm 1B-E

60

ZDm 1A-E

60

ZDm 1AR-E

60

Single-phase

CONTAINER kg

n° pumps

H (mm)

kg

1250

670

100

1990

1106

1250

709

100

1990

1170

1250

726

100

1990

1199

H

0 80

00

12

279


D Submersible drainage pumps ➠ for clear water

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Designed to pump clear or slightly dirty water, these pumps are suitable for use in domestic, civil and professional applications and in particular for draining flooded areas such as cellars and garages, for draining swimming pools and reservoirs and for the disposal of non-sewage waste water. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.

•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 27 m •• 5 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: •• ••

– up to Ø 10 mm for D8-D10-D15 – up to Ø 6 mm for D18-D20 – up to Ø 3 mm for D30 Suction level: – 23 mm above ground level for D8-D10-D18-D20 – 15 mm above ground level for D15-D30 220 mm minimum immersion depth for continuous service

CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 5 m long power cable •• Float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

280

PATENTS - TRADE MARKS - MODELS

•• Patent n° IT1390742, IT1390743

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

D30

D15

Head H (metres) 4

D20

D18 D10 D8

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase

kW

HP

Q

m³/h

0

1.5

3.0

4.5

6.0

l/min

0

25

50

75

100 125 150 175 200 225 250 275 300 325 350 400

7.5

Dm 8

0.55

0.75

12

11.5

11

10.5

Dm 10

D 10

0.75

1

15

14.5

14

13.2 12.5 11.8

Dm 15

D 15

1.1

1.5

Dm 18

0.55

0.75

Dm 20

D 20

0.75

Dm 30

D 30

1.1

Q = Flow rate H = Total manometric head

23

22

17

16.5

1

21

20

19

17.5

1.5

27

26

25

23.5

H metres

21.5 20.5 15

13.5

9.8

9

9.0

10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 24.0

8.2

7.2

6

4.8

3.5

2

11

10

9

8

6.8

5.4

3.5

2

15

13.5

12

11

9

14.5

13

11.5

10

20

19

18

17

16

12

10.7

9

7.7

5

16

15

13.5

12

10

22

21

19.5

18

16

7.5

4

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

281


D POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304 (with mesh filter for D30)

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Technopolymer open type (closed for D30)

5

MOTOR CASING

Stainless steel AISI 304

6

MOTOR CASING PLATE

Stainless steel AISI 304

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

9

LIP SEAL

Ø 15 x Ø 24 x H 5 mm (Ø 16 x Ø 24 x H 5 mm for D15, D30)

10

BEARINGS

6203 ZZ / 6203 ZZ

11

CAPACITOR Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

20 μF 450 VL

30 μF 250 VL

25 μF 450 VL

Dm8 Dm10 Dm18 Dm20 Dm15 Dm30 12

13

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

13

11

POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

14

10

FLOAT SWITCH

5

(only for single-phase versions)

12 9 7 14 10 6

1

282

2

8

4

3


DIMENSIONS AND WEIGHT a

b

MODEL Single-phase Dm 8

c

PORT

Three-phase D 10

Dm 15

D 15

Dm 18

1½”

Dm 20

D 20

Dm 30

D 30

(minimum)

DIMENSIONS mm

DN

Dm 10

d

h1

DN

e

h

p (minimum)

Typical installation

a

b

c

h

h1

d

105

81

136

352

72

23

110

90

140

371

85

15

105

81

136

352

72

23

110

90

140

371

85

15

kg e

1~

p

variable

500

500

3~

11.7

12.7

11.6

14.7

13.7

11.8

13.0

11.7

15.0

14.0

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

Single-phase

230 V

240 V

VOLTAGE (three-phase)

110 V

Three-phase

230 V

400 V

240 V

415 V

Dm 8

3.4 A

3.4 A

6.9 A

D 10

3.6 A

2.1 A

3.6 A

2.1 A

Dm 10

5.2 A

5.2 A

10.5 A

D 15

6.0 A

3.5 A

6.0 A

3.5 A

Dm 15

7.9 A

7.9 A

D 20

3.6 A

2.1 A

3.6 A

2.1 A

Dm 18

3.8 A

3.8 A

7.2 A

D 30

6.0 A

3.5 A

6.0 A

3.5 A

Dm 20

5.4 A

5.4 A

11.0 A

Dm 30

7.2 A

7.2 A

PALLETIZATION MODEL Single-phase Dm 8

Three-phase –

Dm 10

D 10

Dm 15

D 15

Dm 18

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

60

1310

60

1310

kg

3~

n° pumps

H (mm)

1~

720

100

2090

1190

780

711

100

2090 1288

1174 837

3~ –

45

1388

678

632

60

1804

898

60

1310

725

100

2090

1197

60

1310

797

720

100

2090

1317

1188

Dm 30

D 30

45

1388

690

647

60

1804

914

857

0

D 20

80

Dm 20

H

00

12

283


VX-I  "VORTEX" Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 10 m

APPLICATION LIMITS

•• 5 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: ••

– up to Ø 40 mm for VX8/35I - VX10/35I – up to Ø 50 mm for VX8/50I - VX10/50I Minimum immersion depth for continuous service: – 270 mm for VX8/35I - VX10/35I – 300 mm for VX8/50I - VX10/50I

CONSTRUCTION AND SAFETY STANDARDS

INSTALLATION AND USE Suitable for use with sewage water in domestic, civil and industrial applications or in any other situation, such as with water mixed with mud, with groundwater and with surface water, where the water contains suspended solids. They are suitable for use in applications such as for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.

PATENTS - TRADE MARKS - MODELS

•• Patent n° IT1390742, IT1390743

OPTIONALS AVAILABLE ON REQUEST

•• Complete with 5 m long power cable •• Float switch for single-phase versions

•• Pumps with a 10 m long power cable

EN 60335-1 IEC 60335-1 CEI 61-150

•• ••

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

284

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

VX10/35-I

VX8/35-I

Head H (metres) 4

VX10/50-I

VX8/50-I

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase

kW

HP

VXm 8/35-I

Q

m³/h

0

3

6

9

12

15

18

21

24

l/min

0

50

100

150

200

250

300

350

400

0.55

0.75

8.4

7.5

6.5

5.2

3.7

2

VXm 10/35-I VX 10/35-I

0.75

1

10

9.5

8.5

7.2

5.8

4

VXm 8/50-I

0.55

0.75

6

5.5

5

4.4

3.6

2.8

2

1

0.75

1

7.5

7

6.5

5.8

5

4

3.2

2.4

VXm 10/50-I VX 10/50-I

Q = Flow rate H = Total manometric head

H metres

2 1.5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

285


VX-I  "VORTEX" POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 VORTEX type

4

MOTOR CASING

Stainless steel AISI 304

5

MOTOR CASING PLATE

Stainless steel AISI 304

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

8

LIP SEAL

Ø 15 x Ø 24 x H 5 mm

9

BEARINGS

6203 ZZ / 6203 ZZ

10

CAPACITOR

11

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

VXm 8/35-I VXm 8/50-I VXm 10/35-I VXm 10/50-I

20 μF 450 VL

30 μF 250 VL

12

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

12

10 9 4

POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

13

6 11

FLOAT SWITCH

8

9

(only for single-phase versions)

13

5 7

1 2

286

3


DIMENSIONS AND WEIGHT Typical installation

e d

h1

DN

h

p (minimum)

a

(minimum)

b

MODEL

PORT

Single-phase

Three-phase

VXm 8/35-I

VXm 10/35-I

VX 10/35-I

VXm 8/50-I

VXm 10/50-I

VX 10/50-I

DN 1½”

DIMENSIONS mm

solids passage

a

Ø 40 mm

b

108

h

h1

404

d

87

Ø 50 mm

118

e

p

50

166 2”

kg

variable 434

108

500

500

60

1~

3~

9.5

10.8

9.3

9.4

10.6

9.2

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

VXm 8/35-I

3.3 A

3.3 A

7.6 A

VX 10/35-I

3.6 A

2.1 A

3.6 A

2.1 A

VXm 10/35-I

5.0 A

5.0 A

11.5 A

VX 10/50-I

3.6 A

2.1 A

3.6 A

2.1 A

VXm 8/50-I

3.5 A

3.5 A

8.0 A

VXm 10/50-I

5.0 A

5.0 A

11.5 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

kg

3~

n° pumps

H (mm)

1~

3~

Single-phase

Three-phase

VXm 8/35-I

60

1520

588

80

1980

778

VXm 10/35-I

VX 10/35-I

60

1520

662

576

80

1980

877

762

VXm 8/50-I

60

1520

579

80

1980

766

VXm 10/50-I

VX 10/50-I

60

1520

652

569

80

1980

864

753

H

0

80

00

12

287


MC-I

"DOUBLE-CHANNEL"

Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 800 l/min (48 m3/h) •• Head up to 15 m

APPLICATION LIMITS

•• 5 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 50 mm •• 300 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 5 m long power cable •• Float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

288

INSTALLATION AND USE MC-I submersible pumps are suitable for draining dirty water and sewage in domestic and civil applications. They come equipped with a DOUBLE-CHANNEL impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage water, waste water, surface water and water mixed with mud in locations such as holiday homes and detached homes. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.

PATENTS - TRADE MARKS - MODELS

•• Patent n° IT1390742, IT1390743

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 20

0

16

0

40

60

20

40

80

50 Hz  n= 2900 1/min

100

60

120

80

140

100

160

120

180

200

140

220

160

180 feet 50

MC15/50-I

14

45

40

12

Head H (metres) 4

MC10/50-I

35

10 30

8

25

6

20

15

4

10

2 5

0

100

0

200

300

10

0

400 20

MODEL

POWER

Single-phase Three-phase

kW

MCm 10/50-I

MC 10/50-I

0.75

1

MC 15/50-I

1.1

1.5

Q = Flow rate H = Total manometric head

HP

Q

500

600

700

30

0

800

40

Flow rate Q 4

50

m³/h

0

3

6

9

12

15

18

21

24

27

30

36

42

48

l/min

0

50

100

150

200

250

300

350

400

450

500

600

700

800

12

10.7

9.7

8.7

7.8

6.8

5.9

5

4

3

2

15

14

13

12.3

11.5

10.5

9.7

8.8

8

7

6.2

4.5

2.7

1

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

289


MC-I

"DOUBLE-CHANNEL"

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Stainless steel AISI 304, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 DOUBLE-CHANNEL type

4

MOTOR CASING

Stainless steel AISI 304

5

MOTOR CASING PLATE

Stainless steel AISI 304

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

8

LIP SEAL

Ø 15 x Ø 24 x H 5 mm

9

BEARINGS

6203 ZZ / 6203 ZZ

10

CAPACITOR Capacitance

11

(230 V or 240 V)

(110 V)

20 μF 450 VL

30 μF 250 VL

12

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

12

10

9

POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

13

4

FLOAT SWITCH

6

(only for single-phase versions)

11

8

9

13

5 7

1 2

290

3


DIMENSIONS AND WEIGHT Typical installation

e d

h1

DN

h

p (minimum)

a

(minimum)

b

MODEL

PORT

Single-phase

Three-phase

MCm 10/50-I

MC 10/50-I

MC 15/50-I

DIMENSIONS mm

solids passage

DN 2”

a

Ø 50 mm

b

118

h

166

h1

434

108

d 60

kg e

variable

1~

3~

10.9

9.5

10.5

p 500

500

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

MCm 10/50-I

5.0 A

5.0 A

11.5 A

MC 10/50-I MC 15/50-I

415 V

3.6 A

2.1 A

3.6 A

2.1 A

6.1 A

3.5 A

6.1 A

3.5 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

1~

3~

MC 10/50-I

60

1520

671

588

80

1980

889

778

MC 15/50-I

60

1520

645

80

1980

854

Single-phase

Three-phase

MCm 10/50-I –

H

0 80

00

12

291


VX

"VORTEX"

Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

Suitable for use in domestic, civil and industrial applications where the water, such as groundwater, surface water and sewage water, contains suspended solids up to Ø 50 mm. They are suitable for use in applications such as for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.

•• Flow rate up to 500 l/min (30 m³/h) •• Head up to 15 m •• 5 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: ••

– up to Ø 40 mm for VX8-10-15/35 – up to Ø 50 mm for VX8-10-15/50 Minimum immersion depth for continuous service: – 290 mm for VX8-10-15/35 – 320 mm for VX8-10-15/50

CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 5 m long power cable •• VXm versions complete with float switch EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

PATENTS - TRADE MARKS - MODELS

•• Patent n° IT1390742, IT1390743

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

292

1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

VX15/35

Head H (metres) 4

VX15/50 VX10/35

VX8/35 VX10/50 VX8/50

Flow rate Q 4

MODEL

POWER

Single-phase Three-phase VXm 8/35

VXm 10/35

VX 10/35

VXm 15/35

VX 15/35

VXm 8/50

Q

m³/h

0

3

6

9

12

15

18

21

24

27

30

l/min

0

50

100

150

200

250

300

350

400

450

500

7.5

6.5

5.2

3.7

2

9.5

8.5

7.2

5.8

4

2

14

13

11.8

10.5

9

7.5

6

4

2

5.5

5

4.4

3.6

2.8

2

1

kW

HP

0.55

0.75

8.4

0.75

1

10 15 6

1.1

1.5

0.55

0.75

H metres

VXm 10/50

VX 10/50

0.75

1

7.5

7

6.5

5.8

5

4

3.2

2.4

1.5

VXm 15/50

VX 15/50

1.1

1.5

11

10.5

10

9.5

9

8.3

7.5

6.8

6

Q = Flow rate H = Total manometric head

5

4

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

293


VX

"VORTEX"

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 VORTEX type

4

MOTOR CASING

Stainless steel AISI 304

5

MOTOR CASING PLATE

Stainless steel AISI 304

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

8

LIP SEAL

Ø 15 x Ø 24 x H 5 mm for VX 8-10/35-50 Ø 16 x Ø 24 x H 5 mm for VX 15/35-50

9

BEARINGS

6203 ZZ / 6203 ZZ

10

CAPACITOR Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

20 μF 450 VL

30 μF 250 VL

25 μF 450 VL

VXm 8/35 VXm 8/50 VXm 10/35 VXm 10/50 VXm 15/35 VXm 15/50 11

12

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

12

10 9 4

POWER CABLE 5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

13

FLOAT SWITCH (only for single-phase versions)

9

6

8

5

13

7

1 2

294

11

3


DIMENSIONS AND WEIGHT Typical installation

d

h1

DN

e

p (minimum)

h

a

b

MODEL

PORT

Single-phase

Three-phase

VXm 8/35

VXm 10/35

VX 10/35

VXm 15/35

VX 15/35

VXm 8/50

VXm 10/50

VX 10/50

VXm 15/50

VX 15/50

(minimum)

c

DIMENSIONS mm

solids passage

DN 1½”

a

b

105

Ø 40 mm

92 110 2”

Ø 50 mm 115

97

c

h

h1

136

408

125

143

429

130

150

437

153

157

458

159

kg

d

e

p

50 variable

500

500

60

1~

3~

12.4

13.3

12.1

16.3

15.0

12.9

13.9

12.1

17.0

15.6

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

VXm 8/35

3.3 A

3.3 A

7.6 A

VX 10/35

3.6 A

2.1 A

3.6 A

2.1 A

VXm 10/35

5.0 A

5.0 A

11.5 A

VX 15/35

5.4 A

3.1 A

5.4 A

3.1 A

VXm 15/35

6.7 A

6.7 A

VX 10/50

3.6 A

2.1 A

3.6 A

2.1 A

VXm 8/50

3.5 A

3.5 A

8.0 A

VX 15/50

5.4 A

3.1 A

5.4 A

3.1 A

VXm 10/50

5.0 A

5.0 A

11.5 A

VXm 15/50

7.1 A

7.1 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

1~

3~

n° pumps

60

1520

761

80

VXm 10/35

VX 10/35

60

1520

815

744

VXm 15/35

VX 15/35

45

1574

748

692

VXm 8/50

60

1520

791

VXm 10/50

VX 10/50

60

1520

VXm 15/50

VX 15/50

45

1574

VXm 8/35

H (mm)

kg 1~

3~

1980 1009

80

1980 1081

987

60

2052

917

80

1980 1049

851

744

80

1980

1129

986

780

718

60

2052 1034

952

992

H

– 0

H (mm)

Three-phase

80

n° pumps

Single-phase

00

12

295


MC

"DOUBLE-CHANNEL"

Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 800 l/min (48 m³/h) •• Head up to 15 m

APPLICATION LIMITS

•• 5 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 50 mm •• 320 mm minimum immersion depth for continuous service CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 5 m long power cable •• Float switch for single-phase versions EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE MC submersible pumps are suitable for draining dirty water and sewage in domestic and civil applications. They come equipped with a DOUBLE-CHANNEL stainless steel impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage water, waste water, surface water and water mixed with mud in locations such as holiday homes and detached homes. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.

PATENTS - TRADE MARKS - MODELS

•• Patent n° IT1390742, IT1390743

OPTIONALS AVAILABLE ON REQUEST

•• Pumps with a 10 m long power cable •• ••

➠ N.B. Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications Single-phase pumps without float switch Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions

296


CHARACTERISTIC CURVES AND PERFORMANCE DATA 20

0

16

0

40

60

20

40

80

50 Hz  n= 2900 1/min

100

60

120

80

140

100

160

120

180

200

140

220

160

180 feet 50

14 MC12/50

45

40

12

Head H (metres) 4

MC10/50

35

10 30

8

25

6

20

15

4

10

2 5

0

100

0

200

300

10

0

400 20

MODEL

POWER

Single-phase Three-phase

kW

MCm 10/50

MC 10/50

0.75

1

MCm 12/50

MC 12/50

1.1

1.5

Q = Flow rate H = Total manometric head

HP

Q

500

600

700

30

0

800

40

Flow rate Q 4

50

m³/h

0

3

6

9

12

15

18

21

24

27

30

36

42

48

l/min

0

50

100

150

200

250

300

350

400

450

500

600

700

800

12

10.7

9.7

8.7

7.8

6.8

5.9

5

4

3

2

15

14

13

12.3

11.5

10.5

9.7

8.8

8

7

6.2

4.5

2.7

1

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

297


MC

"DOUBLE-CHANNEL"

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 DOUBLE-CHANNEL type

4

MOTOR CASING

Stainless steel AISI 304

5

MOTOR CASING PLATE

Stainless steel AISI 304

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

8

LIP SEAL

Ø 15 x Ø 24 x H 5 mm for MC 10/50 Ø 16 x Ø 24 x H 5 mm for MC 12/50

9

BEARINGS

6203 ZZ / 6203 ZZ

10

CAPACITOR

11

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

MCm 10/50 MCm 12/50

20 μF 450 VL 25 μF 450 VL

30 μF 250 VL –

12

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

12

10

POWER CABLE

4

5 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only) 13

9

11 9

FLOAT SWITCH

6

(only for single-phase versions)

5

8 13

7

1 3 2

298


DIMENSIONS AND WEIGHT Typical installation

d

h1

DN

e

p (minimum)

h

a

b

MODEL

PORT

Single-phase

Three-phase

MCm 10/50

MC 10/50

MCm 12/50

MC 12/50

(minimum)

c

DIMENSIONS mm

solids passage

DN 2”

Ø 50 mm

a

b

c

h

h1

110

92

150

437

153

115

97

157

458

159

kg

d 60

e

1~

3~

14.1

12.9

17.0

15.8

p

variable

500

500

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

MCm 10/50

5.2 A

5.2 A

11.7 A

MC 10/50

3.6 A

2.1 A

3.6 A

2.1 A

MCm 12/50

8.5 A

8.5 A

MC 12/50

6.1 A

3.5 A

6.1 A

3.5 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

1~

3~

MC 10/50

60

1520

865

791

80

1980

1148

1049

MC 12/50

45

1574

784

730

60

2052

1039

968

Single-phase

Three-phase

MCm 10/50 MCm 12/50

H

0 80

00

12

299


DC Submersible drainage pumps ➠ for clear water

PERFORMANCE RANGE

•• Flow rate up to 400 l/min (24 m3/h) •• Head up to 27 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: •• ••

– up to Ø 10 mm for DC8-DC10-DC15 – up to Ø 6 mm for DC20 – up to Ø 3 mm for DC30 Suction level: – 23 mm above ground level for DC8-DC10-DC20 – 15 mm above ground level for DC15-DC30 220 mm minimum immersion depth for continuous service

CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3

300

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE DC submersible pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, are suitable for draining clear or slightly dirty water. They distinguish themselves for their sturdiness and reliability under automatic operating conditions in fixed installations.

OPTIONALS AVAILABLE ON REQUEST

•• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

DC30

DC15

Head H (metres) 4

DC20

DC10 DC8

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

m³/h

0

1.5

3.0

4.5

6.0

l/min

0

25

50

75

100 125 150 175 200 225 250 275 300 325 350 400

7.5

9.0

10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 24.0

DCm 8

0.55

0.75

12

11.5

11

10.5

DCm 10

DC 10

0.75

1

15

14.5

14

13.2 12.5 11.8

DCm 15

DC 15

1.1

1.5

H metres 23

22

20

19

18

DCm 20

DC 20

0.75

1

21

20

19

17.5

16

15

13.5

DCm 30

DC 30

1.1

1.5

27

26

25

23.5

22

21

19.5

18

16

Q = Flow rate H = Total manometric head

21.5 20.5

9.8

9

8.2

7.2

6

4.8

3.5

2

11

10

9

8

6.8

5.4

3.5

2

17

16

15

13.5

12

11

9

12

10 14.5

13

11.5

10

7.5

4

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

301


DC POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

SUCTION FILTER

Stainless steel AISI 304 (with mesh filter for DC30)

3

SUCTION PLATE

Stainless steel AISI 304

4

IMPELLER

Technopolymer open type (closed for DC30)

5

MOTOR CASING

Cast iron

6

MOTOR CASING PLATE

Stainless steel AISI 304

7

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

8

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

9

LIP SEAL

Ø 15 x Ø 24 x H 5 mm for DC8, DC10, DC 20 Ø 16 x Ø 24 x H 5 mm for DC15, DC30

10

BEARINGS

6203 ZZ / 6203 ZZ

11

CAPACITOR Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

20 μF 450 VL

30 μF 250 VL

25 μF 450 VL

DCm8 DCm10 DCm20 DCm15 DCm30 12

13

11

ELECTRIC MOTOR

10

– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8 13

5 7 12

POWER CABLE

9

10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only) 14

10

14

6

FLOAT SWITCH (only for single-phase versions)

1

302

2

8

4

3


DIMENSIONS AND WEIGHT Typical installation

d

h1

DN

e

h

p (minimum)

a

c

MODEL

(minimum)

b

PORT DN

DIMENSIONS mm

Single-phase

Three-phase

a

DCm 8

DCm 10

DC 10

DCm 15

DC 15

DCm 20

DC 20

105

DCm 30

DC 30

110

b

105 1½”

92

110

kg e

1~

p

3~

c

h

h1

d

136

324

72

23

140

343

85

15

136

324

72

23

140

343

85

15

21.5

19.9

variable

500

500

18.6

19.5

17.9

21.6

19.9

19.5

17.9

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

DCm 8

3.4 A

3.4 A

6.9 A

DC 10

3.6 A

2.1 A

3.6 A

2.1 A

DCm 10

5.2 A

5.2 A

10.5 A

DCm 15

7.9 A

7.9 A

DC 15

6.1 A

3.5 A

6.1 A

3.5 A

DCm 20

5.4 A

5.4 A

11.0 A

DC 20

3.6 A

2.1 A

3.6 A

2.1 A

DCm 30

7.2 A

7.2 A

DC 30

6.1 A

3.5 A

6.1 A

3.5 A

PALLETIZATION MODEL

GROUPAGE n° pumps

H (mm)

45

1388

DC 10

45

1388

Single-phase

Three-phase

DCm 8 DCm 10

CONTAINER kg

kg

3~

n° pumps

H (mm)

854

60

1804

1133

894

824

60

1804

1187

1093

1~

1~

3~

DCm 15

DC 15

45

1388

987

913

60

1804

1310

1211

DCm 20

DC 20

45

1388

895

824

60

1804

1187

1093

DCm 30

DC 30

45

1388

985

910

60

1804 1308

1208

H

0

80

00

12

303


VXC  "VORTEX" Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 500 l/min (30 m³/h) •• Head up to 15 m

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

APPLICATION LIMITS

•• 10 m maximum immersion depth •• •• ••

(with a sufficiently long power cable) Maximum liquid temperature +40 °C Solids passage: – up to Ø 40 mm for VXC 8-10-15/35 – up to Ø 50 mm for VXC 8-10-15/45 Minimum immersion depth for continuous service: – 290 mm for VXC 8-10-15/35 – 320 mm for VXC 8-10-15/45

CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3

304

INSTALLATION AND USE VXC series pumps, made from heavy gauge cast iron offering exceptional sturdiness and abrasion resistance, come equipped with a VORTEX impeller and are therefore suitable for draining waste water containing suspended solids, sewage and water mixed with mud.

OPTIONALS AVAILABLE ON REQUEST

•• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

VXC15/35

Head H (metres) 4

VXC15/45 VXC10/35

VXC8/35 VXC10/45 VXC8/45

Flow rate Q 4

MODEL

POWER

Q

m³/h

0

3

6

9

12

15

18

21

24

27

30

l/min

0

50

100

150

200

250

300

350

400

450

500

7.5

6.5

5.2

3.7

2

9.5

8.5

7.2

5.8

4

2

14

13

11.8

10.5

9

7.5

6

4

2

5.5

5

4.4

3.6

2.8

2

1

Single-phase Three-phase

kW

HP

VXCm 8/35

0.55

0.75

8.4

0.75

1

10 15 6

VXCm 10/35 VXC 10/35 VXCm 15/35 VXC 15/35

1.1

1.5

0.55

0.75

VXCm 10/45 VXC 10/45

0.75

1

7.5

7

6.5

5.8

5

4

3.2

2.4

1.5

VXCm 15/45 VXC 15/45

1.1

1.5

11

10.5

10

9.5

9

8.3

7.5

6.8

6

VXCm 8/45

Q = Flow rate H = Total manometric head

H metres

5

4

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

305


VXC  "VORTEX" POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 VORTEX type

4

MOTOR CASING

Cast iron

5

MOTOR CASING PLATE

Stainless steel AISI 304

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

8

LIP SEAL

Ø 15 x Ø 24 x H 5 mm for VXC 8-10/35-45 Ø 16 x Ø 24 x H 5 mm for VXC 15/35-45

9

BEARINGS

6203 ZZ / 6203 ZZ

10

CAPACITOR Pump

Capacitance

Single-phase

(230 V or 240 V)

VXCm 8/35 VXCm 8/45 VXCm 10/35 VXCm 10/45 VXCm 15/35 VXCm 15/45 11

(110 V)

12

20 μF 450 VL

30 μF 250 VL

25 μF 450 VL

10 9

ELECTRIC MOTOR

6

– Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8 12

4 11 9

POWER CABLE

13

13

8

10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

5

FLOAT SWITCH (only for single-phase versions)

1 2 7

306

3


DIMENSIONS AND WEIGHT Typical installation

c

MODEL Single-phase

e (minimum)

b

PORT

Three-phase

VXCm 8/35

VXCm 10/35

VXC 10/35

VXCm 15/35

VXC 15/35

VXCm 8/45

VXCm 10/45

VXC 10/45

VXCm 15/45

VXC 15/45

d

h1

h

DN

p (minimum)

a

DN

solids passage

1½”

Ø 40 mm

DIMENSIONS mm a

b

105 92 110

2”

Ø 50 mm 115

97

c

h

h1

136

380

125

143

401

130

150

409

153

157

430

159

kg

d

e

1~

p

50 variable

500

500

60

3~

19.8

20.0

18.3

22.8

24.4

20.5

20.5

18.7

23.5

21.1

ABSORPTION MODEL

VOLTAGE (single-phase)

MODEL

VOLTAGE (three-phase)

Single-phase

230 V

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

VXCm 8/35

3.3 A

3.3 A

7.6 A

VXC 10/35

3.6 A

2.1 A

3.6 A

2.1 A

VXCm 10/35

5.0 A

5A

11.5 A

VXCm 15/35

6.7 A

6.7 A

VXC 15/35

5.4 A

3.1 A

5.4 A

3.1 A

VXCm 8/45

3.5 A

3.5 A

8.0 A

VXC 10/45

6.6 A

2.1 A

6.6 A

2.1 A

VXCm 10/45

5.0 A

5.0 A

11.5 A

VXCm 15/45

7.1 A

7.1 A

VXC 15/45

5.4 A

3.1 A

5.4 A

3.1 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

n° pumps

H (mm)

1~

kg

3~

n° pumps

H (mm)

1~

3~

Single-phase

Three-phase

VXCm 8/35

45

1400

908

60

1820

1205

VXCm 10/35

VXC 10/35

45

1400

917

838

60

1820

1217

1112

VXCm 15/35

VXC 15/35

45

1574

1042

935

60

2052 1384

1241

VXCm 8/45

45

1400

942

60

1820

VXCm 10/45

VXC 10/45

45

1400

940

859

60

1820

1247

1140

VXCm 15/45

VXC 15/45

45

1574

1076

967

60

2052

1429

1283

1250

H

– 0 80

00

12

307


MC

"DOUBLE-CHANNEL"

Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

MC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a DOUBLE-CHANNEL impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage, waste water, water mixed with mud, groundwater and surface water in locations such as apartment blocks, factories, tower garages, underground car parks and cleaning areas, etc.

•• Flow rate up to 800 l/min (48 m3/h) •• Head up to 15 m •• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Passage of suspended solids up to Ø 50 mm •• 320 mm minimum immersion depth for continuous service

OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

308

•• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


CHARACTERISTIC CURVES AND PERFORMANCE DATA 20

0

16

0

40

60

20

80

40

100

60

50 Hz  n= 2900 1/min 120

80

140

100

160

120

180

200

140

220

160

180 feet 50

14

MC15/45 45

40

12

Head H (metres) 4

MC10/45

35

10 30

8

25

6

20

15

4

10

2 5

0

100

0

200

300

10

0

400 20

MODEL

POWER

Single-phase Three-phase

kW

MCm 10/45

MC 10/45

0.75

1

MCm 15/45

MC 15/45

1.1

1.5

Q = Flow rate H = Total manometric head

HP

Q

500

600

700

30

40

Flow rate Q 4

0

800 50

m³/h

0

3

6

9

12

15

18

21

24

27

30

36

42

48

l/min

0

50

100

150

200

250

300

350

400

450

500

600

700

800

12

10.7

9.7

8.7

7.8

6.8

5.9

5

4

3

2

15

14

13

12.3

11.5

10.5

9.7

8.8

8

7

6.2

4.5

2.7

1

H metres

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

309


MC

"DOUBLE-CHANNEL"

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 DOUBLE-CHANNEL type

4

MOTOR CASING

Cast iron

5

MOTOR CASING PLATE

Stainless steel AISI 304

6

MOTOR SHAFT

Stainless steel EN 10088-3 - 1.4104

7

SHAFT WITH DOUBLE SEAL AND OIL CHAMBER Seal

Shaft

Model

Diameter

MG1-14 SIC

Ø 14 mm

Materials Stationary ring

Rotational ring

Elastomer

Ceramic

Silicon carbide

NBR

8

LIP SEAL

Ø 15 x Ø 24 x H 5 mm for MC 10/45 Ø 16 x Ø 24 x H 5 mm for MC 15/45

9

BEARINGS

6203 ZZ / 6203 ZZ

10

CAPACITOR

11

Pump

Capacitance

Single-phase

(230 V or 240 V)

(110 V)

MCm 10/45 MCm 15/45

20 μF 450 VL 25 μF 450 VL

30 μF 250 VL –

12

ELECTRIC MOTOR – Single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding – Three-phase 400 V - 50 Hz – Insulation: F class – Protection: IP X8

12

10 9 6 4

POWER CABLE 10 metre long “H07 RN-F” cable (with Schuko plug on single-phase versions only)

13

11 9

FLOAT SWITCH

8

(only for single-phase versions)

13

5

1 2

3 7

310


DIMENSIONS AND WEIGHT Typical installation

d

h1

h

DN

e

p (minimum)

a

b

MODEL Single-phase

Three-phase

MCm 10/45

MC 10/45

MCm 15/45

MC 15/45

c

(minimum)

PORT DN

solids passage

2”

Ø 50 mm

DIMENSIONS mm a

b

c

h

h1

110

92

150

409

153

115

97

157

430

159

kg

d

e

p

60

variable

500

500

1~

3~

20.8

19.2

23.7

21.8

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

VOLTAGE (three-phase)

240 V

110 V

Three-phase

230 V

400 V

240 V

415 V

MCm 10/45

5.2 A

5.2 A

11.5 A

MC 10/45

3.6 A

2.1 A

3.6 A

2.1 A

MCm 15/45

8.5 A

8.5 A

MC 15/45

6.1 A

3.5 A

6.1 A

3.5 A

PALLETIZATION MODEL

GROUPAGE

CONTAINER kg

kg

n° pumps

H (mm)

1~

3~

n° pumps

H (mm)

1~

3~

MC 10/45

45

1400

953

881

60

1820

1265

1169

MC 15/45

45

1574

1085

998

60

2052

1441

1325

Single-phase

Three-phase

MCm 10/45 MCm 15/45

H

0

80

00

12

311


VXC  "VORTEX" Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 1200 l/min (72 m3/h) •• Head up to 16 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

INSTALLATION AND USE VXC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a VORTEX impeller and are therefore suitable for draining waste water, sewage, water mixed with mud and sludge. They are ideal for use in sewage installations, tunnels, excavations, canals and underground car parks, etc.

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: ••

– up to Ø 50 mm for VXC 15-20-30/50 – up to Ø 70 mm for VXC 15-20-30/70 Minimum immersion depth for continuous service: – 390 mm for VXC 15-20-30/50 – 430 mm for VXC 15-20-30/70

CONSTRUCTION AND SAFETY STANDARDS

•• Complete with 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

312

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0017

OPTIONALS AVAILABLE ON REQUEST

•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: single-phase three-phase – VXCm 30/50 - HP 3 – VXC 15-20-30/50 - HP 1.5-2-3 – VXCm 30/70 - HP 3 – VXC 15-20-30/70 - HP 1.5-2-3


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

VXC30/50

VXC20/50 VXC15/50

Head H (metres) 4

VXC30/70

VXC20/70

VXC15/70

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

VXCm 15/50

VXC 15/50

1.1

1.5

VXCm 20/50

VXC 20/50

1.5

2

VXCm 30/50

VXC 30/50

2.2

3

VXCm 15/70

VXC 15/70

1.1

1.5

VXCm 20/70

VXC 20/70

1.5

VXCm 30/70

VXC 30/70

2.2

Q = Flow rate H = Total manometric head

Q

m³/h

0

l/min

0

6

12

18

21

24

30

36

42

48

51

54

60

11.5 10.5 13

12

9.5

8.2

7.2

6.5

4.5

2

11

9.5

9

8

6.5

4.5

72

2

16

15

14

13

12.3 11.5

10

8

5.9

3.3

2

6.5

5.5

5

4.7

4.4

3.7

3

2.2

1.5

1

2

8.5

7.4

6.7

6.3

6

5.2

4.5

3.6

2.8

2.4

2

1

3

11

9.7

9

8.6

8.2

7.5

6.7

5.8

5

4.6

4.2

3.3

H metres

66

100 200 300 350 400 500 600 700 800 850 900 1000 1100 1200

2.5

1.5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

313


VXC  "VORTEX" POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Cast iron VORTEX type

4

MOTOR CASING

Cast iron

5

MOTOR CASING PLATE

Cast iron

6

MOTOR SHAFT

Stainless steel AISI 431

7

TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

STA-20 STA-19

Ø 20 mm Ø 19 mm

8

BEARINGS

9

CAPACITOR

Motor side Pump side

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Silicon carbide

Graphite Silicon carbide

NBR NBR

6304 ZZ - C3 / 6304 ZZ - C3

Pump

Capacitance

Single-phase

(230 V or 240 V)

VXCm 15/50 VXCm 15/70 VXCm 20/50 VXCm 20/70 VXCm 30/50 VXCm 30/70 10

Position

8

31.5 μF 450 VL

6

50 μF 450 VL

11

10

60 μF 450 VL

4

ELECTRIC MOTOR VXCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding

8 5

➠ VXCm 30: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding to be connected to the control box.

7

➠ VXC: three-phase 400 V - 50 Hz. with thermal overload protector built-in to the winding to be connected to the control box. – Insulation: F class. – Protection: IP X8. 11

14

POWER CABLE 10 metre long “H07 RN-F” cable

12

1

CONTROL BOX for VXCm 15-20 (only for single-phase versions)

3

2

Complete with capacitor and manual reset motor protector 13

CONTROL BOX for VXCm 30 (only for single-phase versions)

Standard features

QES 300 MONO series 14

FLOAT SWITCH (only for single-phase versions)

Standard features

12

9

9

13

Control box for VXCm 15-20 (only for single-phase versions)

314

Control box for VXCm 30 (only for single-phase versions)


DIMENSIONS AND WEIGHT Typical installation

a

d

h1

e

p (minimum)

h

DN

b

MODEL

PORT

Single-phase

Three-phase

VXCm 15/50

VXC 15/50

VXCm 20/50

VXC 20/50

VXCm 30/50

VXC 30/50

VXCm 15/70

VXC 15/70

VXCm 20/70

VXC 20/70

VXCm 30/70

VXC 30/70

(minimum)

c

DIMENSIONS mm

DN

solids passage

a

b

c

2½”

Ø 50 mm

162

135

210

h 509

h1

d

191

75

522/509 3”

Ø 70 mm

180

150

548

237

kg e

p

variable 233

800

800

85

562/548

1~

3~

36.2

34.9

37.3

36.0

41.2

38.0

36.4

35.1

37.5

36.2

41.5

38.3

ABSORPTION MODEL

MODEL

VOLTAGE (single-phase)

VOLTAGE (three-phase)

Single-phase

230 V

240 V

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

VXCm 15/50

8.8 A

8.8 A

VXC 15/50

5.9 A

3.4 A

2.0 A

5.9 A

3.4 A

2.0 A

VXCm 20/50

10.2 A

10.2 A

VXC 20/50

7.3 A

4.2 A

2.4 A

7.3 A

4.2 A

2.4 A

VXCm 30/50

15.6 A

15.6 A

VXC 30/50

9.9 A

5.7 A

3.3 A

9.9 A

5.7 A

3.3 A

VXCm 15/70

8.7 A

8.7 A

VXC 15/70

5.7 A

3.3 A

1.9 A

5.7 A

3.3 A

1.9 A

VXCm 20/70

10.0 A

10.0 A

VXC 20/70

7.3 A

4.2 A

2.4 A

7.3 A

4.2 A

2.4 A

VXCm 30/70

15.0 A

15.0 A

VXC 30/70

9.5 A

5.5 A

3.2 A

9.5 A

5.5 A

3.2 A

PALLETIZATION MODEL

GROUPAGE / CONTAINER kg

n° pumps

H (mm)

VXC 15/50

24

1751

887

855

VXC 20/50

24

1751

913

882

VXCm 30/50

VXC 30/50

24

1751

1007

930

VXCm 15/70

VXC 15/70

12

1304

454

438

VXCm 20/70

VXC 20/70

12

1304

467

451

VXCm 30/70

VXC 30/70

12

1304

515

477

Single-phase

Three-phase

VXCm 15/50 VXCm 20/50

1~

3~ H

0 80

00

12

315


MC

"DOUBLE-CHANNEL"

Submersible pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 1600 l/min (96 m3/h) •• Head up to 25 m

APPLICATION LIMITS

•• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: ••

– up to Ø 50 mm for MC 15-20-30-40/50 – up to Ø 70 mm for MC 30-40/70 Minimum immersion depth for continuous service: – 390 mm for MC 15-20-30-40/50 – 430 mm for MC 30-40/70

INSTALLATION AND USE MC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a DOUBLE-CHANNEL impeller and are capable of pumping liquids containing short fibred suspended solids. They are ideal for pumping sewage, waste water, water mixed with mud, groundwater and surface water in locations such as apartment blocks, public buildings, factories, tower garages, underground car parks and cleaning areas, etc.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0017

OPTIONALS AVAILABLE ON REQUEST

CONSTRUCTION AND SAFETY STANDARDS

•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

•• Complete with 10 m long power cable •• Float switch for single-phase versions

GUARANTEE

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

316

1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: single-phase three-phase – MCm 30/50 - HP 3 – MC 15-20-30-40/50 - HP 1.5-2-3-4 – MCm 30/70 - HP 3 – MC 30-40/70 - HP 3-4


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min US g.p.m. Imp g.p.m.

25

MC40/50

feet

MC30/50 70

20

Head H (metres) 4

60 MC20/50

15

50

MC15/50

40

10

30

20

5 MC40/70

10

MC30/70

0

0

200

400

600

800

1000

1200

1400

1600

l/min m³/h

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

0

m³/h

0

6

12

18

24

30

36

42

48

l/min

0

100

200

300

400

500

600

700

800

12.5 10.5

8.5

6.5

4.5

3

1

12.5 10.5

8.5

6.5

5

3

54

60

66

72

84

96

900 1000 1100 1200 1400 1600

MCm 15/50

MC 15/50

1.1

1.5

16

14

MCm 20/50

MC 20/50

1.5

2

18

16

MCm 30/50

MC 30/50

2.2

3

24

22

20

18

16

14

12

10

8

6

4

2

MC 40/50

3

4

25

24

22

20

18

16

14

12

10

8

6

4

MCm 30/70

MC 30/70

2.2

3

13

12

11

10.5

9.5

8.5

8

7.5

6.5

6

5

4.5

3

2

MC 40/70

3

4

17

15

14

13.5 12.5

12

11

10.5

9.5

8.5

8

7

5.5

4

Q = Flow rate H = Total manometric head

H metres

14

1

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

317


MC

"DOUBLE-CHANNEL"

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, with threaded port in compliance with ISO 228/1

2

BASE

Stainless steel AISI 304

3

IMPELLER

Stainless steel AISI 304 DOUBLE-CHANNEL type

4

MOTOR CASING

Cast iron

5

MOTOR CASING PLATE

Cast iron

6

MOTOR SHAFT

Stainless steel AISI 431

7

TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER Seal

Shaft

Model

Diameter

STA-20 STA-19

Ø 20 mm Ø 19 mm

8

BEARINGS

9

CAPACITOR

10

Position Motor side Pump side

Materials Stationary ring

Rotational ring

Elastomer

Ceramic Silicon carbide

Graphite Silicon carbide

NBR NBR

6304 ZZ - C3 / 6304 ZZ - C3

Pump

Capacitance

Single-phase

(230 V or 240 V)

MCm 15/50 MCm 20/50 MCm 30/50 MCm 30/70

31.5 μF 450 VL 50 μF 450 VL

8 6

60 μF 450 VL

11

10

ELECTRIC MOTOR

4

MCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding

8

➠ MCm 30: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding to be connected to the control box

5 7

➠ MC: three-phase 400 V - 50 Hz. with thermal overload protector built-in to the winding to be connected to the control box – Insulation: F class – Protection: IP X8 11

POWER CABLE 14

10 metre long “H07 RN-F” cable 12

CONTROL BOX for MCm 15-20 (only for single-phase versions)

1

Complete with capacitor and manual reset motor protector 13

3

2

CONTROL BOX for MCm 30 (only for single-phase versions) QES 300 MONO series

14

Standard features

FLOAT SWITCH (only for single-phase versions)

Standard features

12

9

9

13

Control box for MCm 15-20 (only for single-phase versions)

318

Control box for MCm 30 (only for single-phase versions)


DIMENSIONS AND WEIGHT Typical installation

a

d

h1

e

p (minimum)

h

DN

b

MODEL

PORT

Single-phase Three-phase

DN

MCm 15/50

MC 15/50

MCm 20/50

MC 20/50

MCm 30/50

MC 30/50

MC 40/50

MCm 30/70

MC 30/70

MC 40/70

(minimum)

c

solids passage

DIMENSIONS mm a

b

c

h

h1

kg

d

e

1~

p

509 2½”

Ø 50 mm

162

135

210

522/509

191

75 variable

522 3”

Ø 70 mm

180

150

237

562/548 562

233

800

800

85

3~

36.7

35.4

37.7

36.4

41.9

38.6

42.2

45.0

41.7

45.3

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

240 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

MCm 15/50

9.0 A

9.0 A

MC 15/50

5.5 A

3.2 A

1.8 A

5.5 A

3.2 A

1.8 A

MCm 20/50

10.5 A

10.5 A

MC 20/50

7.4 A

4.3 A

2.5 A

7.4 A

4.3 A

2.5 A

MCm 30/50

15.2 A

15.2 A

MC 30/50

9.9 A

5.7 A

3.3 A

9.9 A

5.7 A

3.3 A

MCm 30/70

15.2 A

15.2 A

MC 40/50

13.5 A

7.8 A

4.5 A

13.5 A

7.8 A

4.5 A

MC 30/70

10.2 A

5.9 A

3.4 A

10.2 A

5.9 A

3.4 A

MC 40/70

13.5 A

7.8 A

4.5 A

13.5 A

7.8 A

4.5 A

PALLETIZATION MODEL Single-phase

Three-phase

GROUPAGE / CONTAINER n° pumps

H (mm)

kg 1~

3~

MCm 15/50

MC 15/50

24

1751

899

867

MCm 20/50

MC 20/50

24

1751

923

891

24

1751

1023

944

24

1751

1031

MCm 30/70

MC 30/70

12

1304

557

517

MC 40/70

12

1304

561

0

MC 30/50 MC 40/50

80

MCm 30/50 –

H

00

12

319


PVXC  "VORTEX" Fixed installation pumps ➠ for sewage water

PERFORMANCE RANGE

•• Flow rate up to 1200 l/min (72 m3/h) •• Head up to 16 m

INSTALLATION AND USE

•• 10 m maximum immersion depth

PVXC series pumps, made from heavy gauge cast iron offering exceptional sturdiness, abrasion resistance and durability, come equipped with a VORTEX impeller and are therefore suitable for draining waste water, water mixed with mud, liquids containing air or gas, as well as sludge. They are suitable for use in fixed sewer, tunnel, well and underground car park installations.

•• Maximum liquid temperature +40 °C •• Solids passage:

PATENTS - TRADE MARKS - MODELS

APPLICATION LIMITS

(with a sufficiently long power cable)

••

– up to Ø 50 mm for PVXC 15-20-30/50 – up to Ø 70 mm for PVXC 15-20-30/70 Minimum immersion depth for continuous service: – 390 mm for PVXC 15-20-30/50 – 440 mm for PVXC 15-20-30/70

CONSTRUCTION AND SAFETY STANDARDS

•• Standard features: base pedestal, threaded delivery counterflange, guide tube supports (the guide tubes are not included)

•• 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

320

•• Registered Community Design n° 342159-0017

OPTIONALS AVAILABLE ON REQUEST

•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: three-phase single-phase – PVXCm 30/50 - HP 3 – PVXC 15-20-30/50 - HP 1.5-2-3 – PVXCm 30/70 - HP 3 – PVXC 15-20-30/70 - HP 1.5-2-3


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min

PVXC30/50

PVXC20/50

Head H (metres) 4

PVXC15/50 PVXC30/70

PVXC20/70

PVXC15/70

Flow rate Q 4

MODEL Single-phase

Three-phase

POWER kW

HP

PVXCm 15/50

PVXC 15/50

1.1

1.5

PVXCm 20/50

PVXC 20/50

1.5

2

PVXCm 30/50

PVXC 30/50

2.2

3

PVXCm 15/70

PVXC 15/70

1.1

1.5

PVXCm 20/70

PVXC 20/70

1.5

PVXCm 30/70

PVXC 30/70

2.2

Q = Flow rate H = Total manometric head

Q

m³/h

0

l/min

0

6

12

18

21

24

27

11.5 10.5 9.5 13

12

36

8.2

7.2

6.5

5.6

4.5

2

11

9.5

9

8

7.2

6.5

4.5

16

15

14

13

12.3 11.5 10.8

6.5

5.5

5

4.7

2

8.5

7.4

6.7

3

11

9.7

9

H metres

30

42

48

51

54

60

66

72

100 200 300 350 400 450 500 600 700 800 850 900 1000 1100 1200 2

10

8

5.9

3.3

2

4.4

4

3.7

3

2.2

1.5

1

6.3

6

5.6

5.2

4.5

3.6

2.8

2.4

2

1

8.6

8.2

7.8

7.5

6.7

5.8

5

4.6

4.2

3.3

2.5

1.5

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

321


PVXC  "VORTEX" POS. CONSTRUCTION CHARACTERISTICS

POS. CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with flanged ports

2

SUCTION PLATE

Cast iron

3

BASE PEDESTAL

Cast iron

4

CONTERFLANGE

Steel, complete with threaded ports in compliance with ISO 228/1

GUIDE TUBE SUPPORTS

Cast iron

6

IMPELLER

Cast iron VORTEX type

7

MOTOR CASING

Cast iron

8

MOTOR CASING PLATE

Cast iron

9

MOTOR SHAFT

Stainless steel AISI 431

Shaft Diameter

STA-20

Ø 20 mm

STA-19

(230 V or 240 V)

PVXCm 15/50-70 PVXCm 20/50-70 PVXCm 30/50-70

31.5 μF 450 VL 50 μF 450 VL 60 μF 450 VL

13 ELECTRIC MOTOR

➠ PVXC: three-phase 400 V - 50 Hz with motor protector built-in to the winding to be connected to the control box – Insulation: F class

Materials Stationary ring Rotational ring

Ceramic Graphite Silicon carbi-Silicon carbiØ 19 mm de de

11 BEARINGS

Capacitance

Single-phase

➠ PVXCm 30: single-phase 230 V - 50 Hz with motor protector built-in to the winding to be connected to the control box

10 TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER

Model

Pump

PVXCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding.

5

Seal

12 CAPACITOR

Elastomer

NBR NBR

6304 ZZ - C3 / 6304 ZZ - C3

– Protection: IP X8

14 POWER CABLE

10 m long “H07 RN-F” cable

15 CONTROL BOX for PVXCm 15-20 (only for single-phase versions)

Complete with capacitor and manual reset motor protector

16 CONTROL BOX for PVXCm 30 (only for single-phase versions)

QES 300 MONO series

17 FLOAT SWITCH

Standard features 15

5 11 9

12

7

14

13 4

5

Control box for PVXCm 15-20 (HP 1.5-2.0) (only for single-phase versions)

11 10

8

Standard features

17

3

1

2

6

12

16

Control box for PVXCm 30 (HP 3.0)

(only for single-phase versions)

322


DIMENSIONS AND WEIGHT Typical installation

a

Guide tubes Ø external 27 mm maximum Ø internal 19.5÷21.5 mm w DN

h

b

g

m

d

c

e

f

n

MODEL

PORT

Single-phase

Three-phase

PVXCm 15/50

PVXC 15/50

PVXCm 20/50

PVXC 20/50

PVXCm 30/50

PVXC 30/50

PVXCm 15/70

PVXC 15/70

PVXCm 20/70

PVXC 20/70

PVXCm 30/70

PVXC 30/70

DN 2½”

solids passage

DIMENSIONS mm a

Ø 50 mm

b 116

c 51

d

e

490

62

f 248

g 52

Ø 70 mm

h

m

442

198

n

w

120

72

457 / 442

60 3”

kg*

150

70

570

85

268

458

92

255

130

112

472 / 458

1~

3~

47.3

46.0

48.4

47.1

52.3

49.2

54.0

52.7

55.1

53.8

59.1

55.9

(*weight includes counterflanges)

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

240 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

PVXCm 15/50

8.8 A

8.8 A

PVXC 15/50

5.9 A

3.4 A

2.0 A

5.9 A

3.4 A

2.0 A

PVXCm 20/50

10.2 A

10.2 A

PVXC 20/50

7.3 A

4.2 A

2.4 A

7.3 A

4.2 A

2.4 A 3.3 A

PVXCm 30/50

15.6 A

15.6 A

PVXC 30/50

9.9 A

5.7 A

3.3 A

9.9 A

5.7 A

PVXCm 15/70

8.7 A

8.7 A

PVXC 15/70

5.7 A

3.3 A

1.9 A

5.7 A

3.3 A

1.9 A

PVXCm 20/70

10.0 A

10.0 A

PVXC 20/70

7.3 A

4.2 A

2.4 A

7.3 A

4.2 A

2.4 A

PVXCm 30/70

15.0 A

15.0 A

PVXC 30/70

9.5 A

5.5 A

3.2 A

9.5 A

5.5 A

3.2 A

PALLETIZATION MODEL

GROUPAGE / CONTAINER

Single-phase

Three-phase

n° pumps

H (mm)

PVXCm 15/50

PVXC 15/50

24

PVXCm 20/50

PVXC 20/50

24

kg 1~

3~

1751

1153

1122

1751

1179

1148 1197

24

1751

1273

12

1304

665

650

PVXCm 20/70

PVXC 20/70

12

1304

679

663

PVXCm 30/70

PVXC 30/70

12

1304

727

688

0

PVXC 30/50 PVXC 15/70

80

PVXCm 30/50 PVXCm 15/70

H

00

12

323


PMC

"DOUBLE-CHANNEL"

Fixed installation pumps ➠ for sewage water

PERFORMANCE RANGE

INSTALLATION AND USE

APPLICATION LIMITS

PMC pumps, made from heavy gauge cast iron offering exceptional sturdiness and abrasion resistance, come equipped with a DOUBLE-CHANNEL stainless steel impeller and are capable of pumping liquids containing short fibred suspended solids. They are ideal for pumping sewage, waste water, water mixed with mud, groundwater and surface water in locations such as apartment blocks, public buildings, factories, tower garages, underground car parks and cleaning areas, etc.

•• Flow rate up to 1600 l/min (96 m3/h) •• Head up to 25 m •• 10 m maximum immersion depth

(with a sufficiently long power cable)

•• Maximum liquid temperature +40 °C •• Solids passage: ••

– up to Ø 50 mm for PMC 15-20-30-40/50 – up to Ø 70 mm for PMC 30-40/70 Minimum immersion depth for continuous service: – 390 mm for PMC 15-20-30-40/50 – 440 mm for PMC 30-40/70

CONSTRUCTION AND SAFETY STANDARDS

•• Standard features: base pedestal, threaded delivery counterflange, guide tube supports (the guide tubes are not included)

•• 10 m long power cable •• Float switch for single-phase versions EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

324

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 342159-0017

OPTIONALS AVAILABLE ON REQUEST

•• QES control box for three-phase pumps •• Single-phase pumps without float switch •• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions ➠ For the following versions the built-in thermal overload protector must be connected to the control box in order for the guarantee to be considered valid: single-phase three-phase – PMCm 30/50 - HP 3 – PMC 15-20-30-40/50 - HP 1.5-2-3-4 – PMCm 30/70 - HP 3 – PMC 30-40/70 - HP 3-4


CHARACTERISTIC CURVES AND PERFORMANCE DATA

50 Hz  n= 2900 1/min US g.p.m.

25

Imp g.p.m. PMC40/50

feet

PMC30/50 70

20

Head H (metres) 4

60 PMC20/50

15

50

PMC15/50

40

10

30

20

5 PMC40/70

10

PMC30/70

0

0

200

400

600

800

1000

1200

1400

1600

l/min m³/h

Flow rate Q 4

MODEL Single-phase Three-phase

POWER kW

HP

Q

0

m³/h

0

6

12

18

24

30

36

42

48

l/min

0

100

200

300

400

500

600

700

800

12.5 10.5

8.5

6.5

4.5

3

1

12.5 10.5

8.5

6.5

5

3

54

60

66

72

84

96

900 1000 1100 1200 1400 1600

PMCm 15/50

PMC 15/50

1.1

1.5

16

14

PMCm 20/50

PMC 20/50

1.5

2

18

16

PMCm 30/50

PMC 30/50

2.2

3

24

22

20

18

16

14

12

10

8

6

4

2

PMC 40/50

3

4

25

24

22

20

18

16

14

12

10

8

6

4

PMCm 30/70

PMC 30/70

2.2

3

13

12

11

10.5

9.5

8.5

8

7.5

6.5

6

5

4.5

3

2

PMC 40/70

3

4

17

15

14

13.5 12.5

12

11

10.5

9.5

8.5

8

7

5.5

4

Q = Flow rate H = Total manometric head

H metres

14

1

Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3.

325


PMC

"DOUBLE-CHANNEL"

POS. CONSTRUCTION CHARACTERISTICS

POS. CONSTRUCTION CHARACTERISTICS

1

PUMP BODY

Cast iron, complete with flanged ports

2

SUCTION PLATE

Cast iron

3

BASE PEDESTAL

Cast iron

4

CONTERFLANGE

Steel, complete with threaded ports in compliance with ISO 228/1

GUIDE TUBE SUPPORTS

Cast iron

6

IMPELLER

Stainless steel AISI 304 DOUBLE-CHANNEL type

7

MOTOR CASING

Cast iron

8

MOTOR CASING PLATE

Cast iron

9

MOTOR SHAFT

Stainless steel AISI 431

Shaft Diameter

STA-20

Ø 20 mm

STA-19

(230 V or 240 V)

PMCm 15/50 PMCm 20/50 PMCm 30/50-70

31.5 μF 450 VL 50 μF 450 VL 60 μF 450 VL

13 ELECTRIC MOTOR

➠ PMC: three-phase 400 V - 50 Hz with motor protector builtin to the winding to be connected to the control box – Insulation: F class

Materials Stationary ring Rotational ring

Ceramic Graphite Silicon carbi-Silicon carbiØ 19 mm de de

11 BEARINGS

Capacitance

Single-phase

➠ PMCm 30: single-phase 230 V - 50 Hz with motor protector built-in to the winding to be connected to the control box

10 TWO MECHANICAL SEALS SEPARATED BY AN OIL CHAMBER

Model

Pump

PMCm 15-20: single-phase 230 V - 50 Hz with thermal overload protector built-in to the winding.

5

Seal

12 CAPACITOR

Elastomer

NBR NBR

– Protection: IP X8

14 POWER CABLE

10 m long “H07 RN-F” cable

15 CONTROL BOX foe PMCm 15-20 (only for single-phase versions)

Complete with capacitor and manual reset motor protector

16 CONTROL BOX for PMCm 30 (only for single-phase versions)

QES 300 MONO series

17 FLOAT SWITCH

6304 ZZ - C3 / 6304 ZZ - C3

Standard features

15

5 11 9

12

7

14

13 4

5

Control box for PMCm 15-20 (HP 1.5-2.0) (only for single-phase versions)

11 10

8

Standard features

17

3

1

2

6

12

16

Control box for PMCm 30 (HP 3.0)

(only for single-phase versions)

326


DIMENSIONS AND WEIGHT Typical installation

a

Guide tubes Ø external 27 mm maximum Ø internal 19.5÷21.5 mm w DN

h

b

g

m

d

c

e

f

n

MODEL

PORT

Single-phase

Three-phase

PMCm 15/50

PMC 15/50

PMCm 20/50

PMC 20/50

PMCm 30/50

PMC 30/50

PMC 40/50

PMCm 30/70

PMC 30/70

PMC 40/70

DN

solids passage

DIMENSIONS mm a

b

c

d

e

f

kg*

g

h

m

n

w

442 2½”

Ø 50 mm

116

51

490

62

248

52

60 3”

Ø 70 mm

198

457 / 442

120

72

1~

3~

47.2

45.9

48.2

46.9

52.2

49.1

52.7

457 150

70

570

85

268

92

472 / 458

255

472

130

112

62.6

59.3

62.9

(*weight includes counterflanges)

ABSORPTION MODEL

VOLTAGE (single-phase)

Single-phase

230 V

MODEL

240 V

VOLTAGE (three-phase)

Three-phase

230 V

400 V

690 V

240 V

415 V

720 V

PMCm 15/50

9.0 A

9.0 A

PMC 15/50

6.1 A

3.5 A

2A

6.1 A

3.5 A

2.0 A

PMCm 20/50

10.5 A

10.5 A

PMC 20/50

7.4 A

4.3 A

2.5 A

7.4 A

4.3 A

2.5 A

PMCm 30/50

15.2 A

15.2 A

PMC 30/50

9.9 A

5.7 A

3.3 A

9.9 A

5.7 A

3.3 A

PMCm 30/70

15.2 A

15.2 A

PMC 40/50

13.5 A

7.8 A

4.5 A

13.5 A

7.8 A

4.5 A

PMC 30/70

10.2 A

5.9 A

3.4 A

10.2 A

5.9 A

3.4 A

PMC 40/70

13.5 A

7.8 A

4.5 A

13.5 A

7.8 A

4.5 A

PALLETIZATION MODEL

GROUPAGE / CONTAINER kg

n° pumps

H (mm)

PMC 15/50

24

1751

PMCm 20/50

PMC 20/50

24

1751

1175

1143

PMCm 30/50

PMC 30/50

24

1751

1275

1196 1283

Single-phase

Three-phase

PMCm 15/50

1~

3~

1151

1119

12

1751

12

1304

769

729

PMC 30/70

12

1304

772

0

PMC 40/50 PMC 30/70

80

– PMCm 30/70

H

00

12

327


SAR

Storage and lifting stations

PERFORMANCE RANGE 0

45

20

0

50 Hz  n= 2900 1/min 40

60

20

40

80

100

60

120

80

140

100

160

120

180 140

200 160

220 US g.p.m. 180

Imp g.p.m. feet 140

CLEAR WASTE WATER - RAINWATER 40

130 120

35

110 100

Head H (metres) 4

30

90

25

80 70

20

60 50

15

40

10

30 20

5 SAR 40

0

0

SAR 100

100

200

SAR 250 SAR 550

300

10

SAR 550 (2 PUMPS)

400

500

600

700

800

l/min 0

1

0 0

10

20

30

Flow rate Q 4

328

40

50

m³/h

0 1


PERFORMANCE RANGE 0

16

50 Hz  n= 2900 1/min

50

0

100 50

150 100

200

250

150

300

200

350

250

US g.p.m.

400 300

Imp g.p.m.

350

feet 50

DIRTY WASTE WATER

15 14 13

40

12

Head H (metres) 4

11 10 30

9 8 7

20

6 5 4

10

3 2 1 0

SAR 40

0 0

SAR 100

200 10

SAR 250 SAR 550

400 20

SAR 550 (2 PUMPS)

600 30

800 40

50

1000 60

1200 70

1400 80

1600 90

l/min 100

0

m³/h

Flow rate Q 4

329


SAR 40 CLEAR WASTE WATER - RAINWATER MODEL

POWER kW

HP

TANK CAPACITY litres

MAXIMUM FLOW RATE l/min

MAXIMUM HEAD metres

SAR 40 - TOP 1

0.25

0.33

40

160

6

SAR 40 - TOP 2

0.37

0.50

40

220

8

SAR 40 - TOP 3

0.55

0.75

40

260

10

SAR 40 - RXm 1

0.25

0.33

40

160

6.5

SAR 40 - RXm 2

0.37

0.50

40

220

9.5

SAR 40 - RXm 3

0.55

0.75

40

220

11.5

COMPONENTS

•• 40-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 5 metres standard issue with Schuko plug •• Non-return valve

DIRTY WASTE WATER MODEL

POWER kW

HP

TANK CAPACITY litres

MAXIMUM FLOW RATE l/min

MAXIMUM HEAD metres

SAR 40 - TOP VORTEX

0.37 0.50

40

180

6.5

SAR 40 - RXm2/20

0.37 0.50

40

180

6.5

COMPONENTS

•• 40-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 5 metres standard issue with Schuko plug •• Non-return valve

OPTIONALS AVAILABLE ON REQUEST

•• Pump with 10 m long power cable.

➠ Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications

330


SAR 100 CLEAR WASTE WATER - RAINWATER MODEL

SAR 100 - TOP 2 SAR 100 - TOP 3 SAR 100 - TOP 4 SAR 100 - TOP MULTI 2 SAR 100 - TOP MULTI 3 SAR 100 - RXm 2 SAR 100 - RXm 3 SAR 100 - Dm 10 SAR 100 - Dm 15 SAR 100 - Dm 20 SAR 100 - Dm 30

POWER kW

HP

TANK CAPACITY litres

MAXIMUM FLOW RATE l/min

MAXIMUM HEAD metres

0.37

0.50

100

220

8

0.55

0.75

100

260

10

0.75

1

100

320

12

0.55

0.75

100

80

40

0.55

0.75

100

120

32

0.37

0.50

100

220

9.5

0.55

0.75

100

220

11.5

0.75

1

100

325

14.5

1.1

1.5

100

400

22

0.75

1

100

200

20

1.1

1.5

100

300

26

MAXIMUM FLOW RATE l/min

MAXIMUM HEAD metres

COMPONENTS

•• 100-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 10 m (standard issue with Schuko plug)

DIRTY WASTE WATER MODEL

SAR 100 - TOP-VORTEX SAR 100 - RXm 2/20 SAR 100 - RXm 3/20 SAR 100 - ZXm 1A/40 SAR 100 - VXm 8/35 SAR 100 - VXm 10/35 SAR 100 - VXm 8/50 SAR 100 - VXm 10/50 SAR 100 - MCm 10/50

POWER kW

HP

TANK CAPACITY litres

0.37

0.50

100

180

6.5

0.37

0.50

100

180

6.5

0.55

0.75

100

180

8

0.60

0.85

100

400

10.5

0.55

0.75

100

250

7.5

0.75

1

100

300

9.5

0.55

0.75

100

350

5.5

0.75

1

100

400

7

0.75

1

100

500

10.7

COMPONENTS

•• 100-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 10 m (standard issue with Schuko plug)

331


SAR 250 CLEAR WASTE WATER - RAINWATER MODEL

SAR 250 - TOP 3 SAR 250 - TOP 4 SAR 250 - TOP 5 SAR 250 - RXm 3 SAR 250 - RXm 4 SAR 250 - RXm 5 SAR 250 - Dm 10 SAR 250 - Dm 15 SAR 250 - Dm 20 SAR 250 - Dm 30

POWER

TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD litres l/min metres

kW

HP

0.55

0.75

250

260

0.75

1

250

320

12

0.92

1.25

250

400

14

0.55

0.75

250

220

11.5

0.75

1

250

260

15

10

1.1

1.5

250

300

19.5

0.75

1

250

325

14.5

1.1

1.5

250

400

22

0.75

1

250

200

20

1.1

1.5

250

300

26

DIRTY WASTE WATER MODEL

SAR 250 - TOP-VORTEX SAR 250 - RXm 3/20 SAR 250 - RXm 4/40 SAR 250 - RXm 5/40 SAR 250 - VXm10/35-I SAR 250 - VXm10/50-I SAR 250 - MCm10/50-I SAR 250 - VXm 10/35 SAR 250 - VXm 15/35 SAR 250 - VXm 10/50 SAR 250 - VXm 15/50 SAR 250 - MCm 10/50 SAR 250 - MCm 12/50

POWER

TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD litres l/min metres

kW

HP

0.37

0.50

250

180

0.55

0.75

250

180

8

0.75

1

250

280

9.5

6.5

1.1

1.5

250

380

12.5

0.75

1

250

300

9.5

0.75

1

250

400

7

0.75

1

250

500

10.7

0.75

1

250

300

9.5

1.1

1.5

250

450

14

0.75

1

250

400

7

1.1

1.5

250

500

10.5

0.75

1

250

500

10.7

1.1

1.5

250

800

14

COMPONENTS

•• 250-litre polyethylene tank with cover plate •• Pump with float switch •• Power cable: 10 m (standard issue with Schuko plug) •• Lowering device (only for VX-I and MC-I versions)

BASE PEDESTAL ELBOW (DUCT FOOT) MODEL PA/1 (VX /35-I) PA/2 (VX /50-I and MC /50-I)

PORTS DN1 1 ½" 2"

DN2 2"

OPTIONALS AVAILABLE ON REQUEST Alarm KIT Kit includes: •• Float switch, Self-powered siren, Control box 300 mm extension kit Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths

DN1

332

DN2

300 mm extension kit for VX-I and MC-I versions Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths •• Longer lowering device


SAR 550 CLEAR WASTE WATER - RAINWATER MODEL

POWER kW

HP

SAR 550 - TOP4

0.75

1

SAR 550 - TOP5

TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD (1 pump) litres metres litri/min 550

320

12

0.92 1.25

550

400

14

SAR 550 - RXm4

0.75

1

550

260

15

SAR 550 - RXm5

1.1

1.5

550

300

19.5

SAR 550 - Dm10

0.75

1

550

325

14.5

SAR 550 - Dm15

1.1

1.5

550

400

22

SAR 550 - Dm20

0.75

1

550

200

20

SAR 550 - Dm30

1.1

1.5

550

300

26

DIRTY WASTE WATER MODEL

POWER kW

HP

SAR 550 - RXm 4/40

0.75

1

SAR 550 - RXm 5/40

1.1

1.5

TANK MAXIMUM MAXIMUM CAPACITY FLOW RATE HEAD (1 pump) litres metres litri/min 550 280 9.5 550

380

12.5

SAR 550 - VXm 10/35-I 0.75

1

550

300

9.5

SAR 550 - VXm 10/50-I 0.75

1

550

400

7

SAR 550 - MCm10/50-I

0.75

1

550

500

10.7

SAR 550 - VXm 10/35

0.75

1

550

300

9.5

SAR 550 - VXm 15/35

1.1

1.5

550

450

14

SAR 550 - VXm 10/50

0.75

1

550

400

7

SAR 550 - VXm 15/50

1.1

1.5

550

500

10.5

SAR 550 - MCm 10/50

0.75

1

550

500

10.7

SAR 550 - MCm 12/50

1.1

1.5

550

800

14

COMPONENTS

•• 550-litre polyethylene tank with cover plate •• Two single-phase pumps •• Power cable: 10 m (standard issue with Schuko plug) •• Control panel •• Three float switches for: 1) the alternate start-up of one of the two pumps, ••

BASE PEDESTAL ELBOW (DUCT FOOT) MODEL PA/1 (VX /35-I) PA/2 (VX /50-I and MC /50-I)

PORTS DN1 1 ½" 2"

DN2 2"

2) maximum level for starting-up the second pump, 3) minimum level for switching the pumps off Lowering device (only for VX-I and MC-I versions)

OPTIONALS AVAILABLE ON REQUEST Alarm KIT Kit includes: •• Float switch, Self-powered siren, Control box 300 mm extension kit Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths

DN1

DN2

300 mm extension kit for VX-I and MC-I versions Kit includes: •• Extension kit for the installation of the polyethylene "SAR" tank at greater depths •• Longer lowering device

333


SAR DIMENSIONS AND WEIGHT MODEL

PORTS I

h I i1

i1

S

b

I

16.1 1½"

410

410

60

14.2 15.3

14.6

SAR 40 - RXm 2/20

15.6

PORTS U

DIMENSIONS mm S

a

b

h

i1

kg i2 28.7

1¼"

30.1 33.6

1½"

SAR 100 - TOP MULTI 2

32.9

SAR 100 - TOP MULTI 3

32.9

1¼"

SAR 100 - RXm2

29.3

SAR 100 - RXm3

29.6

SAR 100 - Dm10

36.2

SAR 100 - Dm15 SAR 100 - Dm20 SAR 100 - Dm30

Ø 110 mm

1½"

SAR 100 - TOP-VORTEX SAR 100 - RXm 2/20

37.9 Ø 50 mm

500 690 645 145 100

36.5 38.5 28.6

1¼"

29.6

SAR 100 - RXm 3/20

29.8

SAR 100 - ZXm 1A/40

35.2

SAR 100 - VXm 8/35

1½"

35.9

SAR 100 - VXm 10/35

36.8

SAR 100 - VXm 8/50

36.4

SAR 100 - VXm 10/50 SAR 100 - MCm 10/50

334

310

SAR 40 - TOP-VORTEX

SAR 100 - TOP4

b

½"

16.9

SAR 100 - TOP3

a

1¼"

SAR 40 - RXm3

SAR 100 - TOP2

i2

kg i1

SAR 40 - TOP3

I

i1

h

14.7

S

h

b

SAR 40 - TOP2

MODEL U

a

14.0

SAR 40 - RXm2

a

DIMENSIONS mm S

SAR 40 - TOP1

SAR 40 - RXm1

U

U

2"

37.4 37.6


DIMENSIONS AND WEIGHT MODEL

PORTS I

Extension kit

SAR 250 - TOP3

DIMENSIONS mm S

a

b

h

i1

kg i2 42.6

1¼"

SAR 250 - TOP4 300 mm

U

46.1

1½"

SAR 250 - TOP5 SAR 250 - RXm3

47.1 43.4

1¼"

SAR 250 - RXm4 I U S

48.7

SAR 250 - RXm5

49.7

SAR 250 - Dm10

48.7

1½"

SAR 250 - Dm15

h

49.0

SAR 250 - Dm30

51.0

SAR 250 - TOP-VORTEX SAR 250 - RXm 3/20 SAR 250 - RXm 4/40

41.1

Ø 1¼" Ø 110 50 700 970 mm mm

SAR 250 - RXm 5/40

i1

50.7

SAR 250 - Dm20

715

250

130

49.0 50.0

1½"

SAR 250 - VXm10/35-I

i2

46.8

SAR 250 - VXm10/50-I a

46.6

2"

SAR 250 - MCm10/50-I b

SAR 250 - VXm 10/35

46.9 49.3

1½"

SAR 250 - VXm 15/35

52.3

SAR 250 - VXm 10/50

49.9

SAR 250 - VXm 15/50

53.0

2"

SAR 250 - MCm 10/50

50.1

SAR 250 - MCm 12/50

53.0

MODEL

Extension kit

PORTS I

300 mm I U S

U I

i3 i1

i1

i2

i3

98.4

SAR 550 - RXm5

100.4

SAR 550 - Dm10

98.4 1½"

102.4

SAR 550 - Dm20

99.0

SAR 550 - Dm30

103.0

SAR 550 - VXm 10/35-I

SAR 550 - VXm 10/35 SAR 550 - VXm 15/35 b

h

SAR 550 - RXm4

SAR 550 - MCm10/50-I

a

b

95.2

SAR 550 - VXm 10/50-I

i2

a

SAR 550 - TOP5

SAR 550 - RXm 5/40 h

i2

S

kg

93.2

SAR 550 - RXm 4/40 i1

U

DIMENSIONS mm

SAR 550 - TOP4

SAR 550 - Dm15

S

43.8

99.0 Ø 50 1350 970 715 250 130 240 101.0 mm 94.6

Ø 110 mm

2"

1½"

SAR 550 - MCm 10/50 SAR 550 - MCm 12/50

94.8 99.6 105.6 100.8

SAR 550 - VXm 10/50 SAR 550 - VXm 15/50

94.2

2"

107.0 101.2 107.0

335


BETTY Portable self-priming pumps

BETTY 60-65

BETTY 1X-2X-3X

BETTYNOX

PERFORMANCE RANGE

CONSTRUCTION AND SAFETY STANDARDS

•• Flow rate up to 50 l/min (3 m³/h) •• Head up to 55 m

EN 60335-1 IEC 60335-1 CEI 61-150

APPLICATION LIMITS

•• Manometric suction lift up to 9 m •• Ambient temperature up to +40 °C •• Max. working pressure 6 bar •• Continuous service S1

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

PERFORMANCE AND CONSTRUCTION CHARACTERISTICS MODEL

PUMP

BETTY 60 BETTY 65 BETTY 1X BETTY 2X BETTY 3X BETTYNOX 1 BETTYNOX 2 BETTYNOX 3

PKSm 60 PKSm 65 JSWm 1CX JSWm 1BX JSWm 1AX JCRm 1C JCRm 1B JCRm 1A

Q l/min 5÷40 5÷50 5÷50 5÷50 5÷50 5÷50 5÷50 5÷50

H metres 38÷5 50÷8 32÷13 36÷15 42÷19 32÷13 36÷15 42÷19

➠ The BETTY series portable pumps come complete with: – a handle – Ø 20 mm hose attachments – 1.5 m long power cable with Schuko plug

336

INSTALLATION AND USE Suitable for use in gardening, horticultural, cleaning and hobby activities, they are suitable for use with any liquid that is compatible with the materials from which they are made.

OPTIONALS AVAILABLE ON REQUEST

•• Other voltages or 60 Hz frequency

GUARANTEE 1 year subject to terms and conditions


DIMENSIONS AND WEIGHT

DN1

Ø2

n1

DN2

Ø1

MODEL h

h1

BETTY 60 BETTY 65

f

PORTS

DIMENSIONS mm

Single-phase DN1 DN2 Ø1 Ø2 1"

1"

f

h

h1

n

n1

20 20 270 273 267 220 160

kg 7.9 9.5

DN1

Ø2

n

DN2

h

h1 Ø1

MODEL

PORTS

DIMENSIONS mm

Single-phase DN1 DN2 Ø1 Ø2

f

f1

h

h1

n

10.0

BETTY 1X BETTY 2X

1"

1"

20 20 433 373 260 255 230 10.7 10.9

BETTY 3X n

MODEL

DN2

PORTS

DIMENSIONS mm

Single-phase DN1 DN2 Ø1 Ø2 h

h1 Ø1

DN1

Ø2

f

f1

f

f1

h

1”

1”

n

kg

20 20 399 339 270 260 198 8.0 9.2

BETTYNOX 3 f1

h1

7.9

BETTYNOX 1 BETTYNOX 2

f

kg

n

PALLETIZATION MODEL Single-phase

GROUPAGE n° pumps

CONTAINER

H (mm)

kg 1~

n° pumps

H (mm)

kg 1~

BETTY 60

30

1265

254

50

2015

412

BETTY 65

30

1265

302

50

2015

492

BETTY 1X

30

1265

317

50

2015

517

BETTY 2X

30

1265

338

50

2015

552

BETTY 3X

30

1265

344

50

2015

562

1265

254

50

2015

412

1265

257

50

2015

417

BETTYNOX 3

30

1265

293

50

2015

477

0

30 30

80

BETTYNOX 1 BETTYNOX 2

H

00

12

337


EASYPUMP Pumps with electronic pressure switch PUMPS WITH EASYPRESS 1 MODEL

POWER kW

HP

PKm 60 - EP 1

0.37

0.50

PKm 65 - EP 1

0.50

0.70

0.75

1

3CPm 80-C - EP 1

0.45

0.60

4CPm 80-C - EP 1

0.60

0.85

3CPm 100 - C - EP 1

0.60

0.85

4CPm 100 - C - EP 1

0.75

1

Single-phase PK series pumps

2CP series pumps 2CPm 25/130 N - EP 1 3÷4CP series pumps

JSW series pumps JSWm 1 B

- EP 1

0.50

0.70

JSWm 1 A

- EP 1

0.60

0.85

JSWm 10 M - EP 1

0.75

1

JSWm 12 M - EP 1

0.90

1.25

JSWm 1 BX - EP 1

0.50

0.70

JSWm 1 AX - EP 1

0.60

0.85

JSWm 10 MX - EP 1

0.75

1

JSWm 12MX - EP 1

0.90

1.25

EASYPUMP - EP 1 COMPONENTS:

•• Single-phase pump •• EASYPRESS-1 with pressure gauge •• GSR quick-fit joint •• 1.5 meters power cable with Schuko plug EASYPUMP - EP 1 Small pumps fitted with an electronic pressure switch that starts and stops the pump as required when a tap is turned on or off. The pump is also protected against dry running.

338


PUMPS WITH EASYPRESS 2 MODEL

POWER kW

HP

1.1

1.5

JSWm 15M - EP 2

1.1

1.5

JSWm 15 MX - EP 2

1.1

1.5

Single-phase 2CP series pumps 2CPm 25/14B - EP 2 JSW series pumps

➠ EASYPRESS 2 for 1.5 HP pumps (1.1 kW)

EASYPUMP - EP 2 COMPONENTS:

•• Single-phase pump •• EASYPRESS-1 with pressure gauge •• GSR quick-fit joint •• 1.5 meters power cable with Schuko plug EASYPUMP - EP 2 Small pumps fitted with an electronic pressure switch that starts and stops the pump as required when a tap is turned on or off. The pump is also protected against dry running.

339


PRESSURE SETS WITH VESSEL

HYDROFRESH 5VT

HYDROFRESH 24 SF

HYDROFRESH 24 CL

HYDROFRESH 60 CL

PERFORMANCE MODEL

POWER

FLOW RATE (1)

SETTING (2)

kW

HP

l/min

bar

0.37 0.37 0.50 0.60

0.50 0.50 0.70 0.85

32 45 50 50

1.4 ÷ 2.8 1.2 ÷ 2.6 1.4 ÷ 2.8 1.8 ÷ 3.2

0.37 0.50 0.37 0.50 0.60 0.75 0.90 1.1

0.50 0.70 0.50 0.70 0.85 1 1.25 1.5

32 40 45 50 50 80 80 80

1.4 ÷ 2.8 1.5 ÷ 3.0 1.2 ÷ 2.6 1.4 ÷ 2.8 1.8 ÷ 3.2 1.4 ÷ 2.8 2.0 ÷ 3.5 2.5 ÷ 4.0

0.37 0.50 0.75 1.1 0.50 0.60 0.75 0.90 1.1 0.50 0.60 0.75 1.1

0.50 0.70 1 1.5 0.70 0.85 1 1.25 1.5 0.70 0.85 1 1.5

32 40 90 120 50 50 80 80 80 50 50 80 80

1.4 ÷ 2.8 1.5 ÷ 3.0 1.8 ÷ 3.2 2.2 ÷ 3.5 1.4 ÷ 2.8 1.8 ÷ 3.2 1.4 ÷ 2.8 2.0 ÷ 3.5 2.5 ÷ 4.0 1.4 ÷ 2.8 1.8 ÷ 3.2 1.4 ÷ 2.8 2.5 ÷ 4.0

0.75 0.90 1.1

1 1.25 1.5

80 80 80

1.4 ÷ 2.8 2.0 ÷ 3.5 2.5 ÷ 4.0

HYDROFRESH 5VT PKm 60 JSWm 1 CX JSWm 1 BX JSWm 1 AX

- 05 VT - 05 VT - 05 VT - 05 VT

HYDROFRESH 24 SF PKm 60 - 24 SF - 24 SF PKm 65 JSWm 1 CX - 24 SF JSWm 1 BX - 24 SF JSWm 1 AX - 24 SF JSWm 10 MX - 24 SF JSWm 12 MX - 24 SF JSWm 15 MX - 24 SF

HYDROFRESH 24 CL PKm 60 - 24 CL PKm 65 - 24 CL CPm 158 - 24 CL CPm 170 - 24 CL JSWm 1 BX - 24 CL JSWm 1 AX - 24 CL JSWm 10 MX - 24 CL JSWm 12 MX - 24 CL JSWm 15 MX - 24 CL JCRm 1 B - 24 CL JCRm 1 A - 24 CL JCRm 10 M - 24 CL JCRm 15 M - 24 CL

HYDROFRESH 60 CL JSWm 10 MX - 60 CL JSWm 12 MX - 60 CL JSWm 15 MX - 60 CL COMPONENTS: •• Single-phase pump •• Tank •• Pressure switch •• Pressure gauge (for 24SF, 24CL and 60CL)

340

•• Hose (for 24CL and 60CL) •• Brass connector •• 1.5 m power cable with Schuko plug

(1) Maximum flow rate at the minimum recommended pressure switch pressure (2) Recommended pressure range


DIMENSIONS AND WEIGHT MODEL

PORTS

a

l

DN2

DN1

h

PKm 60

- 05 VT

h DN2 DN1

h

DN1

a

210

kg

262

6.5

1"

1"

373

210

280

10.5

1"

373

210

280

11.2

JSWm 1 AX - 05 VT

1"

1"

373

210

280

11.5

PKm 60

- 24 SF

PKm 65

PORTS

DIMENSIONS mm l a h

DN1

DN2

1"

1"

360

390

522

WEIGHT kg 12.5

- 24 SF

1"

1"

373

390

530

13.9

JSWm 1 CX - 24 SF

1"

1"

437

390

551

16.5

JSWm 1 BX - 24 SF

1"

1"

437

390

551

17.3

JSWm 1 AX - 24 SF

1"

1"

437

390

551

17.6

JSWm 10 MX - 24 SF

1"

1"

463

390

572

21.0

JSWm 12 MX - 24 SF

1"

1"

463

390

572

22.0

JSWm 15 MX - 24 SF

1"

1"

463

390

572

22.4

PORTS

DIMENSIONS mm l a h

WEIGHT

DN1

DN2

PKm 60

- 24 CL

1"

1"

540

285

503

13.2

PKm 65

- 24 CL

1"

1"

540

285

508

14.8

CPm 158

- 24 CL

1"

1"

540

285

585

19.9

CPm 170

- 24 CL

1¼"

1"

540

285

605

26.3

JSWm 1 BX - 24 CL

1"

1"

540

295

486

17.9

JSWm 1 AX - 24 CL

1"

1"

540

295

486

18.2

JSWm 10 MX - 24 CL

1"

1"

540

345

507

21.6

JSWm 12 MX - 24 CL

1"

1"

540

345

507

22.6

JSWm 15 MX - 24 CL

1"

1"

540

345

507

23.0

JCRm 1 B

- 24 CL

1"

1"

540

285

519

14.3

JCRm 1 A

- 24 CL

1"

1"

540

285

519

14.8

JCRm 10 M - 24 CL

1¼"

1"

540

285

551

17.3

JCRm 15 M - 24 CL

1¼"

1"

540

285

551

18.4

MODEL DN2

JSWm 10 MX - 60 CL

PORTS DN1 1"

DN2 1"

DIMENSIONS mm l a h 750 400 647

kg

WEIGHT kg 28.2

JSWm 12 MX - 60 CL

1"

1"

750

400

647

29.2

JSWm 15 MX - 60 CL

1"

1"

750

400

647

29.6

h

DN1

255

1"

MODEL

l

1"

JSWm 1 CX - 05 VT

a

DN2

DN2

1"

WEIGHT

JSWm 1 BX - 05 VT

MODEL l

DN1

DIMENSIONS mm l a h

l

a

341


COMBIPRESS "CB2" Pressure boosting sets

CB2 - 2CP

OPERATING PRINCIPLES COMBIPRESS are twin pump pressure boosting sets supplied preassembled and ready to install. The sets are designed so that the pumps operate automatically in succession as the demand for water increases. This results in significant energy savings as the second pump only runs at times of high demand. The lead pump is alternated automatically by the control box.

USES

•• Clean water and chemically non-aggressive liquids. •• Water supply: pressure boosting in industrial applications, ••

condominiums, hotels, communities, water treatment plants, campsites, schools, hospitals, barracks, etc Irrigation: playing fields in general (football, golf, etc), agricultural cultivation, artificial snow systems.

CONSTRUCTION CHARACTERISTICS

•• PUMPS •• •• ••

complete with suction and delivery manifolds, ball valves and non-return valves BASE made from sheet metal PRE-INSTALLED control systems, comprising a pressure gauge and two user-adjustable pressure switches (the factory settings are indicated in the following tables), fitted to the delivery manifold. CONTROL BOX complete with door-interlock power switch, low voltage pressure switch command circuit, automatic pump alternation function, thermal overload protection and pump start-up protection (prevents the pumps from continuously starting-up as a result of small and brief supply demands). CB2m: single-phase 230 V - 50 Hz. CB2: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 18.5 kW.

GUARANTEE CONSTRUCTION AND SAFETY STANDARDS EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

342

1 year subject to terms and conditions


PERFORMANCE DATA

50 Hz  n= 2900 1/min  HS= 0 m

MODEL

POWER 1~ 3~

CB2 - 4CP 100-C

kW

Q

HP

MODEL

POWER 1~ 3~

kW

l/min

H metres

2x0.75 2 x 1

m³/h

Q

HP

0

0.6

1.2

2.4

3.6

4.8

7.2

8.4

0

10

20

40

60

80

120

140

50

50

49

47

45

42

37

34

9.6

10.8

12.0

13.2

14.4

15.6

160

180

200

220

240

260

22

17

11

5

30.5 26.5

m³/h

0

2.4

4.8

7.2

l/min

0

40

80

120 160 200 220 240 280 320 360 400 500 600 700 800

9.6 12.0 13.2 14.4 16.8 19.2 21.6 24.0 30.0 36.0 42.0 48.0

39

34 28.5 22

CB2 - 2CP 25/130N

  2x0.75 2 x 1

42

CB2 - 2CP 25/14B

  2x1.1

2 x 1.5

54

52

47.5

41

33

22

CB2 - 2CP 25/16C

  2x1.1

2 x 1.5

47

46

44

40

35

30

27

CB2 - 2CP 25/16B

  2x1.5

2x2

58

56

54

51

47

43

40

37

30

CB2 - 2CP 25/16A

 2x2.2

2x3

68

67 64.5 62

58

54

51

48

41

CB2 - 2CP 32/200C

 2x3

2x4

CB2 - 2CP 32/200B

 2x4

2 x 5.5

CB2 - 2CP 32/210B

 2x5.5

CB2 - 2CP 32/210A

 2x7.5

CB2 - 2CP 40/180C

24 32

70

85

2 x 7.5

94

2 x 10

112

 2x4

2 x 5.5

64

62

43

35

CB2 - 2CP 40/180B

 2x5.5

2 x 7.5

76

73 72.5 72

71.0 70.0

69

67.5

64

59.5

54

46

CB2 - 2CP 40/180A

 2x7.5

2 x 10

88

85 84.5 84 83.0 82.0

81

79.5

76

72

67

60

H metres

66.5 65

15

63 60.5 59

58

55

52

81

79

77

75

74

72

69

66

94

93

91

89

87

86

83

79

111 110.5 110 108 107 106 102

99

61.3 60.5 59.0 57.5

49.5 46.5 36 62

58

49

75

70

56

94

89

74

56 54.5 49

DIMENSIONS AND WEIGHT g g DN2

DN2

d

DN1

e

e

f

f

c

DN1

c

d

h

a

h

a

b

CB2-4CP  •  CB2 -2CP 25/  •  CB2-2CP 32/ MODEL

CB2-2CP 40/

PORTS Three-phase

DN1

CB2 - 4CPm100-C

1½"

1½"

CB2 - 2CPm 25/130N

CB2 - 2CP 25/130N

1½"

1½"

Single-phase

CB2 - 2CPm 25/14B

CB2 - 2CP 25/14B

CB2 - 2CPm 25/16C

CB2 - 2CP 25/16C

CB2 - 2CPm 25/16B

CB2 - 2CP 25/16B

CB2 - 2CP 25/16A

CB2 - 2CP 32/200C

CB2 - 2CP 32/200B

CB2 - 2CP 32/210B

CB2 - 2CP 32/210A

CB2 - 2CP 40/180C

CB2 - 2CP 40/180B

CB2 - 2CP 40/180A

DN2

DIMENSIONS mm a

b

c

520

645

520

600

1½"

615

e

f

g

630

315

190

495

500

620

300

155

420

338

170

455

645 711 910

3"

351 780

80

190

400

2"

500

h

920

980

895

77.5

51.0

50.5

68.5

68.0

68.5

68.0

380

472

780

420

590

210

610

700

3~

305

600

430

1~

305

200 700

100

kg

d

598 2"

b

565

77.5

77.0

80.0

119.0

125.0

156.0

163.0

175.0

185.0

195.0

343


EASYSMALL® Electronic pump controllers

PERFORMANCE RANGE

•• Max flow rate: 200 l/min (12 m3/h) •• Working pressure: 10 bar •• Restarting pressure: 1.5 bar

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 001774928 •• EASYSMALL® registered trade mark n° 1511131

OPTIONALS AVAILABLE ON REQUEST

•• Maximum liquid temperature +50 °C •• Ambient temperature up to +40 °C •• Burst pressure 40 bar •• Protection grade: IP 65 •• Voltage: 230 V - Frequency: 50/60 Hz •• Max current: – 12 A-EASYSMALL-1

– 16 A-EASYSMALL-2

CONSTRUCTION AND SAFETY STANDARDS

•• The easy to replace, tropicalized sealed circuit board offers com••

plete protection from the effects of humidity and is housed in an IP 65 case. The EASYSMALL circuit board has passed the most stringent EMC tests for electromagnetic compatibility (low interference emission and high disturbance immunity), guaranteeing reliable operation in any environment.

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE Flow & pressure sensing device for control and protection of single- phase pumps up to 2 HP (for domestic applications). It starts the pump when there is a drop in system pressure (e.g. a tap opening) and stops the pump when the flow drops below 2 l/min (tap closed)..

344

•• Version with pressure gauge

GUARANTEE 1 year subject to terms and conditions

INSTALLATION EXAMPLES To avoid repeated starts and to save energy, we recommend that EASYSMALL is installed with a small pressure vessel (ES-05).

Tank ES-05 with pre-set 1.2 bar (recommended)

Maximum delivery height 11 m

APPLICATION LIMITS


PRESSURE LOSSES

Pressure losses (m H2O) 4

15

10

5

0

0

50

100

150

200

0

3

6

9

12

MODEL

Power

Flow rate Q 4

l/min m3/h

Volt

Hz

Current

Fittings

Flow rate

Restarting pressure

EASYSMALL-1

kW 0.75

HP 1

230

50/60

12 A

1" x 1"

12 m³/h

1.5 bar

EASYSMALL-2

1.5

2

230

50/60

16 A

1" x 1"

12 m³/h

1.5 bar

DIMENSIONS AND WEIGHT

ACCESSORIES

•• ES-05: Stainless steel vessel of 0.5 l capacity. 1" BSP male thread. •• GSR: 3 piece male unions for quick connection of pump/EASY SMALL.

g

h

c

a

d

e

b

f

MODEL

i

PORTS

l

DIMENSIONS mm f

g

h

kg

a

b

c

d

e

i

EASYSMALL 1-2 1"

1"

1"

56

74 130 100 170 36

ES-05

GSR

l 64 0.7

PALLETIZATION MODEL Single-phase EASYSMALL 1-2

H (mm)

kg

324

1230

247

H

0 80

00

12

345


EASYPRESS® Electronic pump controllers

PERFORMANCE RANGE

PATENTS - TRADE MARKS - MODELS

APPLICATION LIMITS

OPTIONALS AVAILABLE ON REQUEST

•• Max flow rate: 200 l/min (12 m3/h) •• Working pressure: 10 bar •• Restarting pressure: 1.5 bar •• Maximum liquid temperature +65 °C •• Ambient temperature up to +40 °C •• Burst pressure > 40 bar •• Protection: IP 65 •• VOLTAGE: 230 V - Frequency: 50/60 Hz •• Max current: – 10 A EASYPRESS-1

– 16 A EASYPRESS-2

CONSTRUCTION AND SAFETY STANDARDS

•• The easy to replace, resin sealed circuit board offers complete ••

protection from the effects of humidity and is housed in an IP 65 case. The EASYPRESS circuit board has passed the most stringent EMC tests for electromagnetic compatibility (low interference emission and high disturbance immunity), guaranteeing reliable operation in any environment.

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

INSTALLATION AND USE The EASYPRESS series consists of electronic devices designed to start (when a tap is turned on) and stop (when a tap is turned off) single-phase pumps. The microprocessor protects the pump from dangerous working conditions, such as dry running, and allows the pump to be restarted either automatically or manually. It also prevents the pump from starting-up too often when small leaks are present within an installation.

346

•• Registered Community Design n° 868062 •• Patent n° IT 1388969, IT 1388970 •• EASYPRESS® registered trade mark n° 1334481 •• Version with restating pressure 0.8 bar •• Version with restating pressure 2.2 bar •• Version with 1" NPT ports •• Version with cable and Schuko plug and socket •• Version with pressure gauge

GUARANTEE 1 year subject to terms and conditions

START-UP PRESSURE There are three different models available to choose from, each with a different start-up pressure and easily identified by the coloured cap positioned at the rear of EASYPRESS, suitable for delivering supply to different heights.

Maximum delivery height Version 2.2 bar

= 18 m

Version 1.5 bar

= 11 m

Version 0.8 bar

= 5 m


PRESSURE LOSSES

Pressure losses (m H2O) 4

15

10

5

0

0

50

100

0

3

6

150

200

9

12

l/min m3/h

Flow rate Q 4 MODEL

Power

Volt

Hz

Current

Fittings

Flow rate

Restarting pressure

1

230

50/60

10 A

1" x 1"

12 m³/h

1.5 bar

2

230

50/60

16 A

1" x 1"

12 m³/h

1.5 bar

kW

HP

EASYPRESS-1

0.75

EASYPRESS-2

1.5

DIMENSIONS AND WEIGHT c

MODEL EASYPRESS 1-2

PORTS

DIMENSIONS mm

a

kg

a

b

c

d

h

1"

1"

221

174

174

d

1.63

4

6 8

2 bar

10

h

0

Quick-fit joint with o-ring MODEL

FITTING

GSR

1" M b

PALLETIZATION MODEL Single-phase EASYPRESS 1-2

H (mm)

kg

147

1450

257

H

0

80

00

12

347


EASYPRO® Electronic pump controller

PERFORMANCE RANGE

•• Max flow rate: 200 l/min (12 m3/h) •• Working pressure: 10 bar •• Restarting pressure: 2 bar (Adjustable between 1 and 5 bar)

APPLICATION LIMITS

•• Maximum liquid temperature +65 °C •• Ambient temperature up to +40 °C •• Burst pressure: > 40 bar •• Protection: IP 65 •• Voltage: 230 V - Frequency: 50/60 Hz - Max current: 16 A

CONSTRUCTION AND SAFETY STANDARDS

•• Easy to replace, resin sealed circuit board for complete protection from the effects of humidity.

•• The pressure sensor is housed in a separate area, isolated from the circuit board and current carrying components.

•• The EASYPRO circuit board has passed the most stringent EMC

tests for electromagnetic compatibility (low interference emission and high disturbance immunity), guaranteeing reliable operation in any environment.

CERTIFICATIONS COMPANY WITH MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001: QUALITY ISO 14001: ENVIRONMENT AND SAFETY

GUARANTEE 1 year subject to terms and conditions

348

INSTALLATION AND USE EASYPRO® differs from traditional PRESSURE-FLOW REGULATORS as a result of the following innovative characteristics: •• the built-in surge tank; •• the possibility of selecting the restarting pressure of the pump; •• the back-lit LCD display where the pressure and other useful information is indicated. PUMP START-UP PRESSURE EASYPRO® allow to select the restarting pressure of the pump, between 1 and 5 bar. The pressure selection is made using the command button and by following the instructions that appear on the LCD display. A single model is capable of covering a wide range of installation requirements. SURGE TANK EASYPRO® comes complete with a built-in 3 litre surge tank. The substantial accumulation volume combined with its ability to absorb over-pressure, a typical surge tank characteristic, make it suitable for use in installations where other pressure-flow regulators may prove inadequate. In order to guarantee optimum protection and accumulator performance, it is possible to adjust the tank pressure, the factory setting is 1.8 bar, to suit the pump start pressure selected.

PATENTS - TRADE MARKS - MODELS

•• Registered Community Design n° 976824 •• Patent Pending n° IT 1388969, IT 1388970 •• EASYPRO® registered trade mark n° 1334546

OPTIONALS AVAILABLE ON REQUEST

•• Version with 1" NPT ports •• Version with cable and Schuko plug and socket •• Version with pressure gauge


PRESSURE LOSSES

Pressure losses (m H2O) 4

15

10

5

0

0

50

100

0

3

6

150

200

9

12

l/min m3/h

Flow rate Q 4 MODEL EASYPRO

Power kW HP

Volt

Hz

Current

Fittings

Flow rate

Adjustable restarting pressure

1.5

230

50/60

16 A

1" x 1"

12 m³/h

1÷5 bar

2

DIMENSIONS AND WEIGHT c

a

b

EASYPRO

1"

1"

DIMENSIONS mm c

d

e

283 162 192

kg

h 174

2.43 h

PORTS

d

MODEL

e

a

Quick-fit joint with o-ring MODEL

FITTING

GSR

1" M

b

PALLETIZATION MODEL Single-phase

H (mm)

kg

EASYPRO

98

1450

255

H

0

80

00

12

349


ACCESSORIES SF - SPHERICAL TANK MODEL

FITTING

CAPACITY

1"

24 litres

MODEL

FITTING

CAPACITY

24 CL

1"

20 litres

60 CL

1"

60 litres

100 CL

1"

100 litres

200 CL

1½"

200 litres

300 CL

1½"

300 litres

MODEL

FITTING

CAPACITY

05 VT

½"

0.5 litres

8

VT

1"

8 litres

19 VT

1"

19 litres

60 VT

1"

60 litres

100 VT

1"

100 litres

200 VT

1½"

200 litres

300 VT

1½"

300 litres

500 VT

1½"

500 litres

24 SF

•• Maximum working pressure 8 bar •• Replaceable butyl rubber diaphragm

CL - CYLINDRICAL TANKS

•• Maximum working pressure 10 bar •• Replaceable butyl rubber diaphragm

VT - VERTICAL TANKS

•• Maximum working pressure 10 bar (8 bar for 8VT, 19VT) •• Replaceable butyl rubber diaphragm

350


SPHERICAL KIT MODEL KSP-05

KSP-05 •• 0.5 litres spherical tank •• 4-way fitting - 1" gas •• Pressure switch "PSG-1" •• Power cable with Schuko plug KSP-24 •• 24 litres spherical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Pressure switch "PSG-1"

KSP-24

KSD-24 •• 24 litres spherical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Pressure switch "FSG2" (Square D)

CYLINDRICAL KIT KCP-24

MODEL KCP-24 •• 20 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (500 mm) •• Pressure switch "PSG-1" KCD-24 •• 20 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (500 mm) •• Pressure switch "FSG2" (Square D)

KCP-60

MODEL KCP-60 •• 60 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (600 mm) •• Pressure switch "PSG-1" KCD-60 •• 60 litres cylindrical tank •• 0 ÷ 6 bar pressure gauge •• 5-way fitting - 1" gas •• Hose 1" gas (600 mm) •• Pressure switch "FSG2" (Square D)

351


ACCESSORIES AIRFLO - AUTOMATIC AIR FEEDERS MODEL

SUITABLE FOR TANKS

AIRFLO 1

100 ÷ 500 litres

AIRFLO 2

750 ÷ 2000 litres

•• Automatic air feeders suitable for maintaining the air cushion in surge tanks without a diaphragm.

NA - 3-WAY NIPPLE FOR AIR FEEDERS NA 1.00

CENTRAL FITTING DOUBLE FITTING 1" x 1" ½" x ¼" (male/female)

NA 1.50

NA 1.25

1¼" x 1¼"

NA 2.00

MODEL

MODEL

½" x ¼" (male/female)

CENTRAL FITTING DOUBLE FITTING 1½" x 1½" ½" x ¼" (male/female) 2" x 2"

½" x ¼" (male/female)

•• 3-way brass fittings for connections with air feeders (AIRFLO)

PRESSURE SWITCHES

PSG

MODEL

FITTING

STANDARD SETTING ✱

PSG-1

¼" female

PSG-1M

¼" male

1.4 ÷ 2.8 bar

FSG 2

¼" female

1.4 ÷ 2.8 bar

FYG 22

¼" female

5.4 ÷ 7.0 bar

FYG 32

¼" female

8 ÷ 10.5 bar

PT/5 SK (1)

¼" female

1.4 ÷ 2.8 bar

1.4 ÷ 2.8 bar

•• PSG Registered Community Design nº 002248955 (✱) Adjustable (1) Three-phase

FSG

PRESSURE GAUGES MODEL MC 6

MC

FITTING

DIAMETER

SCALE

¼" - central

50 mm

0 ÷ 6 bar

MR 6

¼" - radial

63 mm

0 ÷ 6 bar

MR 10

¼" - radial

63 mm

0 ÷ 10 bar

MR

GLYCERIN FILLED PRESSURE GAUGES

MCG

352

MRG

MODEL

FITTING

DIAMETER

SCALE

MCG 6

¼" - central

50 mm

0 ÷ 6 bar

MRG 6

¼" - radial

63 mm

0 ÷ 6 bar

MRG 10

¼" - radial

63 mm

0 ÷ 10 bar


3 - 5 WAY FITTINGS MODEL

R5 R4 R3

FITTING

R 3 - 3 way

1"

R 4 - 4 way

1"

R 5 - 5 way

1"

•• R 3: three-way brass fittings with 1" gas connections •• R 4: four-way brass fittings with ½" gas and ¼" gas connections •• R 5: five-way brass fittings with 1" gas and ¼" gas connections

HOSES MODEL TF

PIPE

FITTINGS

TF 5

1"

1" x 1"

500 mm

TF 6

1"

1" x 1"

600 mm

TF 10

1"

1" x 1"

1000 mm

•• Flexible EPDM rubber hoses

LENGTH

•• Maximum working pressure 10 bar

HOSES COMPLETE WITH ELBOW TFG

MODEL

PIPE

FITTINGS

TFG 5

¾"

1" x 1"

500 mm

TFG 6

1"

1" x 1"

600 mm

•• Flexible EPDM rubber hoses

LENGTH

•• Maximum working pressure 10 bar

STRAIGHT HOSETAIL FITTINGS MODEL

HOSETAIL

THREADED FITTING

RP 0.75

Ø 25 mm

¾"

RP 1

Ø 30 mm

1"

RP 1.25

Ø 35 mm

1¼"

RP 1.5

Ø 40 mm

1½"

RP 2

Ø 50 mm

2"

•• Nylon fittings CURVED HOSETAIL FITTINGS MODEL

HOSETAIL

THREADED FITTING

RPG 0.75

Ø 25 mm

¾"

RPG 1

Ø 30 mm

1"

RPG 1.25

Ø 35 mm

1¼"

RPG 1.5

Ø 40 mm

1½"

RPG 2

Ø 50 mm

2"

•• Nylon fittings 353


ACCESSORIES FLOAT SWITCHES MODEL

CABLE (*)

LENGTH (*)

0315/3

H07 RN-F or PVC

3 metres

0315/5

H07 RN-F or PVC

5 metres

0315/10

H07 RN-F or PVC

10 metres

•• With H07 RN-F cable: single function (emptying) floats, with 10 A switch •• With PVC cable: dual function (emptying and filling) floats, with 10 A switch

MODEL

CABLE (*)

LENGTH (*)

T 80/3

H07 RN-F or PVC

3 metres

T 80/5

H07 RN-F or PVC

5 metres

T 80/10

H07 RN-F or PVC

10 metres

•• With H07 RN-F cable: - single function (emptying) floats,

•• With PVC cable:

with double watertight protection chamber and 10 A switch - dual function (emptying and filling) floats - double watertight protection chamber and 10 A switch

MODEL

CABLE (*)

LENGTH (*)

SMALL 3

H07 RN-F or PVC

3 metres

SMALL 5

H07 RN-F or PVC

5 metres

•• With H07 RN-F cable: -single function (emptying) floats,

•• With PVC cable:

with double watertight protection chamber and 10 A switch - dual function (emptying and filling) floats - double watertight protection chamber and 10 A switch

(*) ➠ When ordering, please specify cable length (3, 5 or 10 metres) and type (H07 RN-F or PVC)

MODEL

CABLE

LENGTH

MAC 5

PVC

10 metres

•• Tilting float: - dual function (emptying and filling)

- double watertight protection chamber with 10 A switch

➠ Recommended for use with waste water collection stations (SAR)

354


VF - FOOT VALVES MODEL

FITTING

VF 0.5

½"

VF 0.75

¾"

VF 1

1"

VF 1.25

1¼"

VF 1.5

1½"

VF 2

2"

•• Brass foot valves, stainless steel suction filter

VR - CHECK VALVES MODEL

FITTINGS

VR 0.5

½"

VR 0.75

¾"

VR 1

1"

VR 1.25

1¼"

VR 1.5

1½"

VR 2

2"

•• Brass check valves

VR-FT - BALL CHECK VALVES MODEL

FITTINGS

VR-FT 1.25 - THREADED

1¼"

VR-FT 1.5 - THREADED

1½"

VR-FT 2 - THREADED

2"

•• Check valves for submersible pumps (sewage and waste water) •• Max. working pressure 10 bar •• Min. working pressure 0.3 bar •• Working temperature -10°C ÷ +80 °C

VR-FF - BALL CHECK VALVES MODEL

FITTINGS

VR-FF/DN 65 - FLANGED

Ø 65 mm

VR-FF/DN 80 - FLANGED

Ø 80 mm

•• Check valves for submersible pumps (sewage and waste water) •• Max. working pressure 10 bar •• Min. working pressure 0.3 bar •• Working temperature -10°C ÷ +80 °C 355


ACCESSORIES F - FILTER HOLDERS WITH PLASTIC HEAD MODEL

THREADED FITTINGS

CARTRIDGE HEIGHT

¾"

5"

MEDIUM - F 0.75 MEDIUM - F 1

1"

5"

JUNIOR - F 0.75

¾"

7"

JUNIOR - F 1

1"

7"

SENIOR - F 0.75

¾"

10"

SENIOR - F 1

1"

10"

•• Maximum working pressure 5 bar (at temp. +20°C) •• Maximum temperature + 45°C (at pressure 2 bar) Wrench for filter holders F

RL - POLYESTER FILTER CARTRIDGES MODEL

FILTRATION

CARTRIDGE HEIGHT

FILTER HOLDER

RL 5

50 µ

5"

MEDIUM F

RL 7

50 µ

7"

JUNIOR F

RL 10

50 µ

10"

SENIOR F

FA - POLYPROPYLENE FILTER CARTRIDGES MODEL

FILTRATION

CARTRIDGE HEIGHT

FILTER HOLDER

FA 5

50 µ

5"

MEDIUM F

FA 7

50 µ

7"

JUNIOR F

FA 10

50 µ

10"

SENIOR F

HA - FILTER CARTRIDGE WITH POLYPHOSPHATE CRYSTALS MODEL HA 10

CARTRIDGE HEIGHT

FILTER HOLDER

10"

SENIOR F

LA - FILTER CARTRIDGE WITH ACTIVATED CARBON

356

MODEL

CARTRIDGE HEIGHT

FILTER HOLDER

LA 10 BX

10"

SENIOR F


FLAT PVC HOSE MODEL

FITTING

Ø INTERNAL

LENGTHS

TP 1.25

1¼"

32 mm

5 - 10 - 20 metres

TP 1.50

1½"

40 mm

5 - 10 - 20 metres

TP 2.00

2"

52 mm

5 - 10 - 20 metres

TP 2.50

2½"

63 mm

5 - 10 - 20 metres

TP 3.00

3"

76 mm

5 - 10 - 20 metres

•• Flat, abrasion and weather resistant plasticized delivery hoses, complete with hosetail. ➠ Ideal for irrigation even with fertilisers and for draining water in combination with DRAINAGE PUMPS

GARDEN KIT - SUCTION HOSE MODEL

FITTING

LENGTH

1"

7 metres

GARDEN KIT

•• Hose complete with foot valve ➠ Recommended for use with portable garden pumps such "BETTY"

MT 1 - MECHANICAL FLOW METRE MODEL

MAXIMUM FLOW RATE

MAXIMUM PRESSURE

FITTINGS

120 l/min

3.5 bar

1" x 1"

MT 1

•• Mechanical flow metre for private use, suitable for measuring diesel fuel ➠ Recommended for use with "CK" series pumps

NZ - DISPENSING NOZZLE WITH HOSE MODEL NZ

ELBOW CONNECTION 1” or ¾"

•• Aluminium dispensing nozzle complete with 4 meters long hose, reinforced with steel spiral, with threaded fittings

➠ Recommended for use with "CKm 50-BP or CK 50-BP" series pumps

357


ACCESSORIES TEFLON TAPE FOR HYDRAULIC JOINTS MODEL

LENGTH

TFN 1

12 m

TFN 2

30 m

TFN 3 ¾"

12 m

AEROSOL PAINT MODEL

COLOUR

CAPACITY

SPRAY 1

Pedrollo blue

400 ml

"3M" ELECTRICAL CABLE RESIN JOINT KIT No. OF CORES

CABLE SECTION

RPS 1

4

1 ÷ 2.5 mm²

EXTERNAL JUNCTION DIAMETRE Ø 32 mm

RPS 2

4

1 ÷ 10 mm²

Ø 42 mm

RPS 3

4

4 ÷ 16 mm²

Ø 48 mm

MODEL

(RECOMMENDED)

"3M" ELECTRICAL CABLE HEAT-SHRINK JOINT KIT MODEL

(ECONOMICAL)

358

No. OF CORES

CABLE SECTION

GPS 1

4

1 ÷ 2.5 mm²

GPS 2

4

4 ÷ 6 mm²

GPS 3

4

10

mm²

GPS 4

4

16

mm²

GPS 5

4

25

mm²

GPS 6

4

35

mm²


CAPACITORS MODEL

type F= faston

06 F 10 F 10 FC (*) 12 F 14 F 16 F - 500 16 F - 450 16 F - 250 20 F - 500 20 F - 450 25 F - 450 25 F - 250 30 F - 450 30 F - 250 31 F 35 F 40 F 45 F 50 F 60 F - 450 60 F - 300 60 F - 250 70 F 80 F

CAPACITANCE

Voltage

Frequency

6.3 µF 10 µF 10 µF 12.5 µF 14 µF

450 V 450 V 450 V 450 V 450 V 500 V 450 V 250 V 500 V 450 V 450 V 250 V 450 V 250 V 450 V 450 V 450 V 450 V 450 V 450 V 300 V 250 V 450 V 250 V

50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz

CAPACITANCE

Voltage

Frequency

10 µF 12.5 µF

450 V 450 V 500 V 450 V 500 V 450 V 500 V 450 V 250 V 500 V 450 V 500 V 450 V 450 V 450 V 250 V 250 V 450 V 250 V

50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz 50 ÷ 60 Hz

16 µF 20 µF 25 µF 30 µF 31.5 µF 35 µF 40 µF 45 µF 50 µF 60 µF 70 µF 80 µF

•• Capacitors with CE marking and VDE-IMQ approval

(*) FC = Special capacitor with reduced dimensions

CAPACITORS MODEL

type C= with cable

10 C 12 C 16 C - 500 16 C - 450 20 C - 500 20 C - 450 25 C - 500 25 C - 450 30 C - 250 31 C - 500 31 C - 450 35 C - 500 35 C - 450 40 C 50 C 60 C 70 C 75 C 80 C

16 µF 20 µF 25 µF 30 µF 31.5 µF 35 µF 40 µF 50 µF 60 µF 70 µF 75 µF 80 µF

•• Capacitors with CE marking and VDE-IMQ approval

359


ACCESSORIES ELECTRICAL CABLE FOR LEVEL PROBES MODEL

SECTION

WEIGHT PER METRE

CSL

1.5 mm²

0.019 kg

POWER CABLE FOR SUBMERSIBLE PUMPS MODEL

MODEL

WEIGHT PER METRE

mm²

H07 RN-F

0.165 kg

4 x 1.5 mm²

H07 RN-F

0.205 kg

4 x 2.5 mm²

H07 RN-F

0.290 kg

4 x 4

mm²

H07 RN-F

0.420 kg

4 x 6

mm²

H07 RN-F

0.505 kg

4 x 10 mm²

H07 RN-F

1.030 kg

4 x 16 mm²

H07 RN-F

2.050 kg

4 x 1

POWER CABLE WITH PLUG MODEL

360

CABLE SECTION

LENGTH

PLUG

H05 VV-F (PVC)

3 x 0.75 mm²

150 cm

SCHUKO

H07 RN-F (NEOPRENE)

3x1

150 cm

SCHUKO

mm²


BEARINGS MODEL 6201 ZZ 6201 2RS - C3 6202 ZZ - C3 6203 ZZ 6203 ZZ - C3 6203 ZZ - C3E 6203 2RS 6204 ZZ - C3 6204 ZZ - C3E 6205 ZZ 6206 ZZ - C3 6208 ZZ - C3 6212 ZZ - C3 6303 ZZ - C3 6303 2RS - C3 6304 ZZ 6304 ZZ - C3 6304 2RS - C3 6306 ZZ - C3 6307 ZZ - C3 6308 ZZ - C3 6309 ZZ - C3 6310 ZZ - C3 6312 ZZ - C3 6314 ZZ - C3 3203 B - C3

INTERNAL PLAY

DIMENSIONS

Normal Increased Increased Normal Increased Increased Normal Increased Increased Normal Increased Increased Increased Increased Increased Normal Increased Increased Increased Increased Increased Increased Increased Increased Increased Increased

12 x 32 x 10 mm 12 x 32 x 10 mm 15 x 35 x 11 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 17 x 40 x 12 mm 20 x 47 x 14 mm 20 x 47 x 14 mm 25 x 52 x 15 mm 30 x 62 x 16 mm 40 x 80 x 18 mm 60 x 110 x 22 mm 17 x 47 x 14 mm 17 x 47 x 14 mm 20 x 52 x 15 mm 20 x 52 x 15 mm 20 x 52 x 15 mm 30 x 72 x 19 mm 35 x 80 x 21 mm 40 x 90 x 23 mm 45 x 100 x 25 mm 50 x 110 x 27 mm 60 x 130 x 31 mm 70 x 150 x 35 mm 17 x 40 x 17.5 mm

FANS MODEL

DIMENSIONS

SHAFT DIAMETER

14VN059 14VN07 14VN075 14VN08 14VN081 14VN0815 14VN09 14VN95 14VN10 14VN10162 14VN132 14VN180

104 x 21 mm 125 x 24 mm 118 x 22 mm 138 x 27 mm 132 x 27 mm 132 x 27 mm 162 x 32 mm 148 x 33 mm 176 x 38 mm 155 x 37 mm 165 x 45 mm 240 x 60 mm

12 mm 14.5 mm 14.5 mm 20 mm 20 mm 20 mm 24 mm 24 mm 28 mm 28 mm 36 mm 55 mm

361


CABLE SIZES FOR SUBMERSIBLE MOTORS SINGLE-PHASE 230 V - 50 Hz MOTOR POWER kW

HP

0.37 0.55 0.75 1.1 1.5 2.2

0.50 0.75 1 1.5 2 3

cable section in mm2 4x1

4 x 1.5

4 x 2.5

60 45 35 25

90 70 50 35 30

140 110 85 60 45 30

4x4

4x6

4 x 10

4 x 16

240 190 125

305 200

maximum cable length in metres 180 140 95 75 50

210 145 115 75

THREE-PHASE 230 V - 50 Hz MOTOR POWER kW

HP

0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9.2 11 13 15 18.5 22 30

0.50 0.75 1 1.5 2 3 4 5.5 7.5 10 12.5 15 17.5 20 25 30 40

cable section in mm2 4x1

4 x 1.5

4 x 2.5

4x4

4x6

4 x 10

4 x 16

4 x 25

4 x 35

4 x 50

4 x 70

385 275 220 190 164 144 114 95 70

395 315 270 236 205 162 137 102

378 330 287 225 190 142

4 x 25

4 x 35

4 x 50

4 x 70

585 470 405 350 305 245 205 152

490 430 340 285 210

485 410 305

570 425

maximum cable length in metres 100 83 65 48

152 126 99 72 53

255 210 165 120 88 60 47

338 265 192 142 97 73 55

405 292 215 147 110 83 60 45

485 360 245 183 138 100 73 64 54

392 295 220 160 114 100 87 75 65

510 380 275 195 157 135 117 102 82 69

THREE-PHASE 400 V - 50 Hz MOTOR POWER kW

HP

0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9.2 11 13 15 18.5 22 30

0.50 0.75 1 1.5 2 3 4 5.5 7.5 10 12.5 15 17.5 20 25 30 40

cable section in mm2 4x1

4 x 1.5

4 x 2.5

4x4

4x6

300 250 195 145 105 70 55 40

380 295 215 160 110 85 60 45 35

360 265 180 140 105 75 55 47 40

425 290 220 165 120 95 75 65 60 50

440 330 250 180 135 115 95 85 75 58 49 36

Voltage drop 3% - Maximum environment temperature + 30 째C

366

4 x 10

4 x 16

maximum cable length in metres

415 300 220 190 160 140 125 100 85 63

480 340 300 260 225 195 155 130 96


CONTROL BOXES QEM - CONTROL BOXES FOR 4" SINGLE-PHASE BOREHOLE PUMPS MODEL

MOTOR POWER

CAPACITOR

RATED CURRENT

Single-phase

kW

HP

CAPACITANCE

A

QEM 050

0.37

0.50

20 µF

5

QEM 075

0.55

0.75

25 µF

6

QEM 100

0.75

1

35 µF

7

QEM 150

1.1

1.5

40 µF

11

QEM 200

1.5

2

60 µF

13

QEM 300

2.2

3

75 µF

18

•• Single-phase 230 V 50 Hz

QET - CONTROL BOXES FOR 4" AND 6" THREE-PHASE BOREHOLE PUMPS MODEL

MOTOR POWER

RATED CURRENT

Three-phase

kW

HP

A

QET 050

0.37

0.50

1.7

QET 075

0.55

0.75

2

QET 100

0.75

1

2.5

QET 150

1.1

1.5

3.9

QET 200

1.5

2

4.8

QET 300

2.2

3

7

QET 400

3

4

9

QET 550

4

5.5

11.5

QET 750

5.5

7.5

15.5

QET 1000

7.5

10

21.5

QET 1250

9.2

12.5

23.5

QET 1500

11

15

27.5

QET 2000

15

20

36

QET 2500

18.5

25

45

QET 3000

22

30

54

QET 4000

30

40

68

•• The control box has a selector for manual or automatic operation (with float switch, pressure switch, etc.).

•• Three-phase 400 V 50 Hz

362


QSM - CONTROL BOXES FOR 4" SINGLE-PHASE PUMPS WITH LEVEL PROBES

Level probes

MODEL

MOTOR POWER

CAPACITOR

RATED CURRENT

Single-phase

kW

HP

CAPACITANCE

A

QSM 050

0.37

0.50

20 µF

5

QSM 075

0.55

0.75

25 µF

6

QSM 100

0.75

1

35 µF

7

QSM 150

1.1

1.5

40 µF

11

QSM 200

1.5

2

60 µF

13

QSM 300

2.2

3

75 µF

17.5

•• The control box has a selector for manual or automatic operation (with float switch, pressure ••

switch, etc.) and may be connected to level probes that protect the pump against dry running. Single-phase 230 V 50 Hz

QST - CONTROL BOXES FOR 4"AND 6" THREE-PHASE PUMPS WITH LEVEL PROBES MODEL

Level probes

MOTOR POWER

RATED CURRENT

Three-phase

kW

HP

A

QST 50

0.37

0.50

1.7

QST 75

0.55

0.75

2

QST 100

0.75

1

2.5

QST 150

1.1

1.5

3.9

QST 200

1.5

2

4.8

QST 300

2.2

3

7

QST 400

3

4

9

QST 550

4

5.5

11.5

QST 750

5.5

7.5

15.5

QST 1000

7.5

10

21.5

QST 1250

9.2

12.5

23.5

QST 1500

11

15

27.5

QST 2000

15

20

36

QST 2500

18.5

25

45

QST 3000

22

30

54

QST 4000

30

40

68

•• The control box has a selector for manual or automatic operation (with float switch, pres••

sure switch, etc.) and may be connected to level probes that protect the pump against dry running. Three-phase 400 V 50 Hz

363


CONTROL BOXES EVOLUTION - CONTROL BOXES FOR 4" AND 6" BOREHOLE PUMPS MODEL

VOLTAGE

RATED CURRENT A

Single-phase 230 V 50 Hz Three-phase 400 V 50 Hz Three-phase 400 V 50 Hz

EVOLUTION-MONO EVOLUTION-TRI/1 EVOLUTION-TRI/2

from 2 to 18 from 2 to 16 from 16 to 22

•• The control box contains a circuit board that makes it possible to adjust the limit at which the over••

load and shot-circuit protection intervenes; the circuit board also protects the pump against dry running by controlling the cos φ value without additional level probes. The control box may be connected to a float switch (or a pressure switch, etc.).

QES - CONTROL BOXES FOR SINGLE PHASE DRAINAGE PUMPS MODEL

MOTOR POWER

CAPACITOR

RATED CURRENT

Single-phase

kW

HP

CAPACITANCE

A

QES 300 MONO

2.2

3

60 µF

16

QES 300 MONO-AL (*)

2.2

3

60 µF

16

➠ The control box is designed for connection to the thermal protector built into the motor windings of the VXCm30, PVXCm30, MCm30, PMCm30 drainage pumps. (*) QES 300 MONO-AL, control box with contacts for connection to an auxiliary float switch for level alarm

•• Single-phase 230 V 50 Hz

QES - CONTROL BOXES FOR THREE PHASE DRAINAGE PUMPS MODEL

MOTOR POWER

RATED CURRENT

Three-phase

kW

HP

A

QES 150

1.1

1.5

4.2

QES 200

1.5

2

5.2

QES 300

2.2

3

6.5

QES 400

3

4

8

➠ The control box comes complete with a selector for manual or automatic operation (with float switch) and is designed for connection to the thermal protector built into the motor windings of the VXC, PVXC, MC, PMC drainage pumps.

•• Three-phase 380 ÷ 415V 50 Hz 364


QED 1 - ELECTRONIC CONTROL BOX FOR 1 DRAINAGE PUMP MODEL

VOLTAGE

RATED CURRENT A

QED 1- MONO QED 1- TRI

single-phase 230 V 50 Hz Three-phase 400 V 50 Hz

from 2 to 18 from 2 to 9

➠ The control box is designed for connection to the thermal protector built into the motor windings of the VXC, PVXC, MC and PMC drainage pumps.

•• The control box is designed to be connected to three float switches (start-up, shut-off and alarm level).

•• The control box contains an electronic card that makes it possible to regulate the threshold at which the protection intervenes against overload currents and short-circuits.

QED 2 - ELECTRONIC CONTROL BOX FOR 2 DRAINAGE PUMPS MODEL

VOLTAGE

RATED CURRENT A

QED 2- MONO QED 2- TRI

single-phase 230 V 50 Hz Three-phase 400 V 50 Hz

from 2 to 18 from 2 to 9

➠ The control box is designed for connection to the thermal protector built into the motor windings of the VXC, PVXC, MC and PMC drainage pumps.

•• The control box is designed to be connected to four float switches (alternate start-up of the first pump, alternate start-up of the second pump, shut-off and alarm level)

•• The control box contains an electronic card that makes it possible to regulate the threshold at which the protection intervenes against overload currents and short-circuits.

365


CONVERSION OF UNITS OF MEASUREMENT LENGTH millimetre

centimetre

metre

inch

yard

mm

cm

m

in

ft

yd

1 10 1000 25.4 304.8 914.4

0.1 1 100 2.54 30.48 91.44

0.001 0.01 1 0.0254 0.3048 0.9144

0.0394 0.3937 393.701 1 12 36

0.0033 0.0328 3.2808 0.0833 1 3

0.0011 0.0109 10.936 0.0278 0.3333 1

foot

1 kilometre = 1000 metres = 0.62137 miles – 1 mile = 1609.34 metres = 1.60934 kilometres

VOLUME cubic metre

litre

millilitre

Inperial gallon

US gallon

cubic foot

m3

l

ml

Imp. gal.

US gal

ft3

1000 1 0.001 4.546 3.785 28.317

1 x 10 6 1000 1 4546 3785 28.317

220 0.22 2.2 x 10 -4 1 0.8327 6.2288

264.2 0.2642 2.642 x 10 -4 1.201 1 7.4805

35.3147 0.0353 3.53 x 10 -5 0.1605 0.1337 1

kilogram

pound

hundredweight

ton

long ton

short ton

kg

lb

cwt

t

tn

sh. tn

0.001 4.54 x 10 -4 0.0508 1 1.0161 0.9072

9.84 x 10 -4

0.0011 5.0 x 10 -4 0.056 1.1023 1.102 1

1 0.001 1 x 10 -6 0.00455 0.00378 0.0283

WEIGHT 1 0.454 50.802 1000 1016 907.2

2.205 1 112 2204.6 2240 2000

0.0197 0.0089 1 19.684 20 17.857

4.46 x 10 -4 0.05 0.9842 1 0.8929

VOLUMETRIC FLOW RATE litres second

litres minute

cubic metres hour

cubic feet hour

cubic feet minute

Imp. gal. minute

US gal. minute

l/s 1 0.017 0.278 0.008 0.472 0.076 0.063 0.002

l/min 60 1 16.667 0.472 28.317 4.546 3.785 0.110

m3/h 3.6 0.06 1 0.0283 1.6990 0.2728 0.2271 0.0066

ft3/h 127.133 2.1189 35.3147 1 60 9.6326 8.0209 0.2339

ft3/min 2.1189 0.0353 0.5886 0.0167 1 0.1605 0.1337 0.0039

Imp. gal/min 13.2 0.22 3.666 0.104 6.229 1 0.833 0.024

US gal/min 15.85 0.264 4.403 0.125 7.480 1.201 1 0.029

US barrel day (oil) US barrel/g 543.439 9.057 150.955 4.275 256.475 41.175 34.286 1

PRESSURE AND HEAD Newton square metre N/m2

kiloPascal

bar

kilogram force square centimetre

pound force square inch

foot of water

metre of water

millimetre mercury

inch mercury

(Pa) 1 1000 100000 98067 6895 2984 9789 133.3 3386

kPa 0.001 1 100 98.07 6.895 2.984 9.789 0.133 3.386

bar 1 x 10 -5 0.01 1 0.981 0.069 0.03 0.098 0.0013 0.0338

kgf/cm2 1.02 x 10 -5 1.02 x 10 -2 1.02 1 0.0703 0.0305 0.1 0.0014 0.0345

psi 1.45 x 10 -4 0.145 14.5 14.22 1 0.433 1.42 0.019 0.491

ft H20 3.35 x 10 -4 0.335 33.52 32.81 2.31 1 3.28 0.045 1.133

m H20 1.02 x 10 -4 0.102 10.2 10 0.703 0.305 1 0.014 0.345

mm Hg

In Hg

0.0075 7.5 750.1 735.6 51.72 22.42 73.42 1 25.4

2.95 x 10 -4 0.295 29.53 28.96 2.036 0.882 2.891 0.039 1

368


FRICTION LOSS CHART (for straight pipes with 15-250 mm internal diameter and flow rates from 8 to 8330 l/min)

ee

di

nm

/s

100

Wa ter

sp

50 30 20

10

Loss in metres per 100 metres of pipe

4.6

5 3 2

1

0.5 0.3 0.2

0.1

0.05 0.03 0.02

0.01

8

16

30

50

83

160

330

500

830

1660

3330 5000

8330 Q l/min

0.5

1

2

3

5

10

20

30

50

100

200

500

Q m3/h

Flow rate

300

The data in the table refers to cold water and other liquids with the same kinematic viscosity and new cast iron pipes. The load losses (hv) indicated in the table must be multiplied by: 0.8 for new steel pipes, 1.25 for old, slightly rusty iron pipes, and 1.7 for old pipes where the build-up of incrustation must be taken into account. ➠ EXAMPLE: Flow rate data Q = 500 l/min, new steel pipe Ø 80 mm, pipe length 50 m. Find the flow rate on the horizontal axis and move vertically until you meet the DN 80 mm line. The corresponding load losses can thus be found on the vertical axis. hv = 4,6 m for every 100 m of pipe. hv1 = 4,6 x 0.8 = 3.68 m/100 (steel pipe). Considering the real length of the pipe: hv2 = 3,68 x 50:100 = 1.84 m (for 50 m of pipe). The flow speed is determined by considering the position of the intersection point, which is between the oblique lines with value of 1.5-2 m/sec. In the case considered that gives: C = 1.7 metres/sec

367


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.