GENERAL CATALOGUE 2005
Pedrollo’s aim is to move water all over the world, with creativeness and passion. Our pumps are suitable for all purposes, easy to use, ecological, accessible to everyone, everywhere. Our mission is to make water available everywhere, supporting life, development and comfort.
Organized on an area of 70,000 m2 our company makes use of a production process characterised by a high level of technology and automation, putting it at the top of its sector both for the amount of investments and for the ability to ensure quality throughout the production process. Pedrollo pumps are distributed in 160 countries, thus allowing our company to assume an international role that results in a yearly production of close to 2,000,000 units. The range comprises more than 60 families of pumps (drainage pumps, submerged and surface pumps) covering the majority of applications in the domestic, civil, agricultural and industrial sectors.
Pedrollo’s aim is to move water all over the world, with creativeness and passion. Our pumps are suitable for all purposes, easy to use, ecological, accessible to everyone, everywhere. Our mission is to make water available everywhere, supporting life, development and comfort.
Organized on an area of 70,000 m2 our company makes use of a production process characterised by a high level of technology and automation, putting it at the top of its sector both for the amount of investments and for the ability to ensure quality throughout the production process. Pedrollo pumps are distributed in 160 countries, thus allowing our company to assume an international role that results in a yearly production of close to 2,000,000 units. The range comprises more than 60 families of pumps (drainage pumps, submerged and surface pumps) covering the majority of applications in the domestic, civil, agricultural and industrial sectors.
A highly advanced research and development centre, endowed with the most sophisticated work tools, both hardware and software, allows the continuous updating of the existing range as well as the planning of new products using materials of the latest generation.
A highly advanced research and development centre, endowed with the most sophisticated work tools, both hardware and software, allows the continuous updating of the existing range as well as the planning of new products using materials of the latest generation.
The heart of the pump is certainly the electric motor. It is therefore necessary to guarantee not only the best quality of the components used, but also that the execution of the various passages of the winding (insulation, coils, impregnation, etc.) is carried out using the most advanced automatic machines, to guarantee the precision and constancy of the various steps.
The heart of the pump is certainly the electric motor. It is therefore necessary to guarantee not only the best quality of the components used, but also that the execution of the various passages of the winding (insulation, coils, impregnation, etc.) is carried out using the most advanced automatic machines, to guarantee the precision and constancy of the various steps.
Before obtaining approval for the production phase, a technologically advanced test room, equipped with the latest test benches, allows strict electrical and hydraulic testing to ensure the quality and effectiveness of the design phase.
Before obtaining approval for the production phase, a technologically advanced test room, equipped with the latest test benches, allows strict electrical and hydraulic testing to ensure the quality and effectiveness of the design phase.
The final assembly of our pumps is carried out on automatic lines which guarantee maximum precision in the assembly phase and a high speed of execution, to ensure that the finished product is available in a short time.
The final assembly of our pumps is carried out on automatic lines which guarantee maximum precision in the assembly phase and a high speed of execution, to ensure that the finished product is available in a short time.
1979 - GOLD MEDAL: Awarded by the Verona Chamber of Commerce for having achieved a top level on the technical and commercial plain, in both the national and international field.
1993 - MARCO POLO Prize: Awarded by the Foreign Trade section of the Chamber of Commerce of the Veneto as the best firm, having distinguished itself in 1992 for its economic growth in the international field.
1994 - GOLD MEDAL: Awarded by the Verona Chamber of Commerce for having carried out considerable technical improvements in the firm.
1995 - COMPANY TO WATCH: Awarded by the DATABANK as “company of the year” for the results achieved.
1997 - PUMP TO WATCH: Awarded by the DATABANK to the TOP “submersible pump of the year” for its design and advanced technology.
2000 - PUMP TO WATCH: Awarded by the DATABANK to the 4SR “submerged pump of the year” for its advanced technological features.
2000 - QUALITY OF LIFE prize: awarded the entrepreneur and the firm “for greater sensitivity to the company’s impact on the community and for the ability to integrate the growth of the company with continuous and coherent programmes for the support of culture, art, the environment and the social scene”. (Milan - Assolombarda)
2001 - ENTREPRENEUR OF THE YEAR Prize 2001: awarded, at national level, the entrepreneur and the firm “for sensitivity to the social scene and continuous attention to the most needy populations, for the product which responds to the primary needs of man, such as certainly the availability of water”. (Milan - Assolombarda)
2002 - ENTERPRISE AND CULTURE Prize: Prize of the Italian Manufacturers’ Association, awarded to the project with the highest social value. For efficacy in using culture as a primary resource of social communication and cooperation, in some economically handicapped and problematic countries on the world scene. (Naples - Palazzo Reale)
2002 - CREATIVITY AND INNOVATION Prize: Awarded by the Association of Industrialists of the province of Verona for having achieved world leadership in the sector of pumps.
2003 - CEREC Prize: Awarded by the European Committee for the approach to Economy and Culture for the “Pedrollo for life” project in favour of developing countries, in particular for the recovery of Albanian culture and for commitment in favour of the development of Bangladesh. (Naples - Palazzo Reale)
2004 - DOMUS MERCATORUM Prize: Awarded by the Verona Chamber of Commerce for the development of new technologies, taking the company to the top world levels in the production of pumps for civil, industrial and agricultural applications.
1979 - GOLD MEDAL: Awarded by the Verona Chamber of Commerce for having achieved a top level on the technical and commercial plain, in both the national and international field.
1993 - MARCO POLO Prize: Awarded by the Foreign Trade section of the Chamber of Commerce of the Veneto as the best firm, having distinguished itself in 1992 for its economic growth in the international field.
1994 - GOLD MEDAL: Awarded by the Verona Chamber of Commerce for having carried out considerable technical improvements in the firm.
1995 - COMPANY TO WATCH: Awarded by the DATABANK as “company of the year” for the results achieved.
1997 - PUMP TO WATCH: Awarded by the DATABANK to the TOP “submersible pump of the year” for its design and advanced technology.
2000 - PUMP TO WATCH: Awarded by the DATABANK to the 4SR “submerged pump of the year” for its advanced technological features.
2000 - QUALITY OF LIFE prize: awarded the entrepreneur and the firm “for greater sensitivity to the company’s impact on the community and for the ability to integrate the growth of the company with continuous and coherent programmes for the support of culture, art, the environment and the social scene”. (Milan - Assolombarda)
2001 - ENTREPRENEUR OF THE YEAR Prize 2001: awarded, at national level, the entrepreneur and the firm “for sensitivity to the social scene and continuous attention to the most needy populations, for the product which responds to the primary needs of man, such as certainly the availability of water”. (Milan - Assolombarda)
2002 - ENTERPRISE AND CULTURE Prize: Prize of the Italian Manufacturers’ Association, awarded to the project with the highest social value. For efficacy in using culture as a primary resource of social communication and cooperation, in some economically handicapped and problematic countries on the world scene. (Naples - Palazzo Reale)
2002 - CREATIVITY AND INNOVATION Prize: Awarded by the Association of Industrialists of the province of Verona for having achieved world leadership in the sector of pumps.
2003 - CEREC Prize: Awarded by the European Committee for the approach to Economy and Culture for the “Pedrollo for life” project in favour of developing countries, in particular for the recovery of Albanian culture and for commitment in favour of the development of Bangladesh. (Naples - Palazzo Reale)
2004 - DOMUS MERCATORUM Prize: Awarded by the Verona Chamber of Commerce for the development of new technologies, taking the company to the top world levels in the production of pumps for civil, industrial and agricultural applications.
VERTICAL
PERIPHERAL PK
BRONZE
page 16
PQ
page 20
PQ 3000
page 22
PQA
page 24
PV
page 26
VL
page 118
VLE
page 122
STAINLESS STEEL AL-RED
page 30
PRO-NGA
page 48
3-4 CR
page 60
CENTRIFUGAL CP
CP DIN
page 28 page 32
page 38
JCR HF
PK PQ CP
page 101 page 102 page 103
SUBMERGED 4SK
page 108
5SK
page 110
4BLOCK
page 126
SUMO
page 114
4SR
page 130
6SR
page 144
page 72
TOP MULTI page 112
page 40
SELF-PRIMING NF
page 44
PKS
page 18
SUBMERSIBLE NGA
page 46
JSW
page 62
TOP
page 156
TOP FLOOR page 158 F
page 82
JDW
page 68
TOP VORTEX page 160 PLURIJET
page 74
MULTI-STAGE RX
2CP
page 50
CK
page 78
3-4CP
page 58
CKR
page 80
page 162
RX VORTEX page 164
ZD
page 166
MC
page 188
ZX
page 168
PVXC
page 190
D
page 170
PMC
page 192
VX
page 172
PORTABLE BETTY
page 104
BETTYNOX page 107 MC
page 174
HYDROFRESH VX-I
page 176 page 196
MC-I
page 178
COMBIPRESS DC
page 180 page 201รท213
VXC
page 182
MOTORS MC
page 184
VXC
page 186
Km1 56รท90 page 218
ACCESSORIES page 220
electropumps with peripheral impeller
RANGEOFPERFORMANCE Flow rate up to 90 l/min (5.4 m3/h) Head up to 100 m
GUARANTEE YEARS accordingto to our general terms of sale. of sale. subject our general terms GUARANTEE 12YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 8 m Liquid temperature up to + 60°C Environment temperature up to + 40°C EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
●
● ● ● ●
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY, SIMPLICITY OF USE AND ECONOMY THEY ARE SUITABLE FOR DOMESTIC USE AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL AUTOCLAVES, FOR IRRIGATING GARDENS. The pumps must be installed in enclosed places, or at least protected against inclement weather.
● ● ●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. LANTERN (patent nº 1289150): aluminium with front shim disk in brass; reduces starting difficulties due to blockage of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PKm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. PK: three-phase 230/400 V- 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753. PKm 60® is a REGISTERED TRADE MARK nº 602636.
EXECUTIONSONREQUEST
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PK300
Head H
(metres)
PK200 PK90 PK100
PK80 PK70
PK65
PK60
Flow rate Q
TYPE Single-phase PKm 60® PKm 65 PKm 70 PKm 80 PKm 90 PKm 100 PKm 200 –––
POWER
Three-phase PK 60® PK 65 PK 70 PK 80 PK 90 PK 100 PK 200 PK 300
kW
Q
HP
0.37 0.50 0.60 0.75 0.75 1.1 1.5 2.2
m3/h
0
l/min
0
0.3
40 0.50 55 0.70 65 0.85 1 H metres 70 90 1 85 1.5 90 2 100 3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
5.4
50
60
70
80
90
25 30 40
15 20 30
10 20
10
5
10
15
20
25
30
35
40
38 50 62 66 82 80 86 95
33.5 45.5 57 61 71 75 81 90
29 40.5 52 56 60 70 76 85
24 36 47 51 49 65 71 80
19.5 31 42 46 38 60 65.5 75
15 27 37 41 27 55 60 70
10 22 32 36.5 17 50 55 65
5 17 27 31 5 45 50 60
Q = Flow rate H = Total manometric head
8 18 22 35 40 50
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS f
i
h1
DN1
h3
h
h2
DN2
w
a
Single-phase PKm 60® PKm 65 PKm 70 PKm 80 PKm 90 PKm 100 PKm 200 –––
TYPE Three-phase PK 60® PK 65 PK 70 PK 80 PK 90 PK 100 PK 200 PK 300
n1 n
s
m
INLETS DN1
DN2
1" 1" 1" 1" 1" 3/4" 1" 1" 1" 1"
1" 1" 1" 1" 1" 3/4" 1" 1" 1"
a 42 48 55 55 55 58 55 55 55
f 243 258/250 285 285 285 288 322 348 342/322 342
h 152 152 152 179 179 179 203 212 203
h1 63 63 63 71 71 71 80 80 80
h2 75 80 85 85 85 95 94 94 94 94
DIMENSIONS mm h3 i m 138 20 80 80 143 20 80 156 20 90 156 156 20 90 20 166 20 90 174 20 100 100 174 174 20 174 20 100
kg n 120 120 120 138 138 138 158 158 158
n1 100 100 100 112 112 112 112 125 125 125 125
w 55 55 55 62 62 62 85 85 95 95
s 7 7 77 7 7 9 99 9
1~ 5.3 7.7 10.1 10.3 10.3 10.3 15.0 16.0 –––
3~ 5.3 6.4 9.2 9.9 9.3 13.1 15.2 18.0
electropumps with peripheral impeller recommended for industrial uses
RANGEOFPERFORMANCE Flow rate up to 90 l/min (5.4 m3/h) Head up to 100 m
.GUARANTEE GUARANTEE 2 YEARS according ourgeneral general terms of sale. subject to to our terms of sale. 1 YEAR
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 8 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ●
● ●
EXECUTIONANDSAFETYSTANDARDS
● ●
EN 60034-1 IEC 34-1 CEI 2-3
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY: brass for PQ 81-Bs LANTERN (patent nº 1289150): aluminium with front shim disk in brass; reduces starting difficulties due to blockage of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PQm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. PQ: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753
USESANDINSTALLATIONS
●
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials
●
of which the pump is made. THE HYDRAULIC CHARACTERISTICS OF THESE PUMPS, TOGETHER WITH THEIR COMPACTNESS, MAKE THEM SUITABLE FOR USE IN THE INDUSTRIAL SECTOR. The pumps must be installed in enclosed places, or at least protected against inclement weather
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal protection IP 55 other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PQ300
PQ200
Head H
(metres)
PQ100
PQ80 PQ70
PQ65
PQ60
PQ81-81Bs PQ90
Flow rate Q
TYPE Single-phase PQm 60 PQm 65 PQm 70 PQm 80 PQm 90 PQm 100 PQm 200 –––
POWER
Three-phase PQ 60 PQ 65 PQ 70 PQ 80 PQ 90 PQ 100 PQ 200 PQ 300
kW
0.37 0.50 0.60 0.75 0.75 1.1 1.5 2.2
TYPE Single-phase PQm 81 PQm 81-Bs
Q
HP
kW
0.50 0.50
0
l/min
0
40 0.50 55 0.70 65 0.85 1 H metres 70 90 1 85 1.5 90 2 100 3
POWER
Three-phase PQ 81 PQ 81-Bs
m3/h
Q
HP
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
5.4
5
10
15
38 50 62 66 82 80 86 95
33.5 45.5 57 61 71 75 81 90
29 40.5 52 56 60 70 76 85
20
25
30
35
40
50
60
70
80
90
24 36 47 51 49 65 71 80
19.5 31 42 46 38 60 65.5 75
15 27 37 41 27 55 60 70
10 22 32 36.5 17 50 55 65
5 17 27 31 5 45 50 60
25 30 40
15 20 30
10 20
10
8 18 22 35 40 50
3
m /h
0
0.12
0.24
0.36
0.48
0.60
0.72
0.84
0.96
l/min
0
2
4
6
8
10
12
14
16
18
90 90
80 80
71 71
63 63
54 54
45 45
37 37
28 28
19 19
10 10
0.70 H 0.70 metres
Q = Flow rate H = Total manometric head
1.08
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS i
f
h1
h3
h
h2
DN1
DN2
n1 n
s
a
TYPE Single-phase Three-phase PQm 60 PQ 60 PQm 65 PQ 65 PQm 70 PQ 70 PQm 80 PQ 80 PQm 81 PQ 81 PQm 81-Bs PQ 81-Bs PQm 90 PQ 90 PQm 100 PQ 100 PQm 200 PQ 200 ––– PQ 300
w
m
INLETS DN1
DN2
1" 1" 1" 1" 1" 1/2" 1/2 " 1/2" 3/4" 1" 1" 1" 1"
1" 1" 1" 1" 1" 1/2" 1/2 " 1/2" 3/4" 1" 1" 1" 1"
a f h 22 223 152 152 22 234/227 152 22 22 253 179 253 179 22 253 179 18 227/220 152 227/220 18 18 227/220 152 152 22 253 179 25 292 203 25 312/292 203 318 212 25 25 312 203
h1 108 113 121 121 121 118 118 118 126 140 140 140 140
h2 30 30 30 30 30 23 23 23 27 30 30 30 30
DIMENSIONS mm h3 i m 138 78 80 78 80 143 78 80 151 83 90 151 83 90 151 83 90 141 71 80 141 71 80 141 71 80 153 84 90 170 89 100 170 89 100 170 100 170 89 100
kg n 120 120 120 138 138 138 120 120 120 138 158 158 158
n1 100 100 100 112 112 112 100 100 100 112 125 125 125
w 55 57 62 62 62 58 58 58 62 85 85 85 85
s 7 7 7 77 7 7 7 9 99 9
1~ 5.3 7.1 9.9 10.0 6.7 6.8 10.0 14.8 15.7 –––
3~ 5.3 6.3 8.9 8.8 6.8 6.8 9.0 14.3 14.8 15.7
electropump with peripheral impeller for industrial uses
LOGO TONDO SU TESTATA OTTONE
RANGEOFPERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 180 m
GUARANTEE YEARS according our general general terms of sale. GUARANTEE 1 2 YEAR subject totoour terms of sale. CONSTRUCTIONCHARACTERISTICS ●
LIMIT S OF USE Manometric suction height up to 8 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ●
● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3
● ●
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: brass with front shim disk in stainless steel. LANTERN (patent nº 1289150): aluminium with front shim disk in brass and stainless steel; eliminates blockage of the impeller after long periods of inactivity. IMPELLER: bronze, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pump is coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PQ 3000: three-phase 230/400 V - 50 Hz. INSULATION: class H. ● PROTECTION: IP 55.
USESANDINSTALLATIONS It is recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made.THE HYDRAULIC CHARACTERISTICS OF THIS PUMP, TOGETHER WITH ITS COMPACTNESS AND STURDINESS, MAKE IT SUITABLE FOR USE IN THE INDUSTRIAL SECTOR. The pump must be installed in enclosed places, or at least protected against inclement weather.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Head H
(metres)
PQ3000
Flow rate Q
TYPE
POWER
Three-phase
kW
HP
PQ 3000
2.2
3
m3/h
0
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
10
15
20
25
30
35
40
45
50
180
160
145
132
118
105
92
78
63.5
50
Q H metres
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
i
h1
h
h3
DN1
h2
DN2
s a
w
n1
m
n
TYPE Three-phase
DN1
INLETS DN2
a
f
h
h1
h2
PQ 3000
3/4"
3/4"
34
329
212
142
38
DIMENSIONS mm h3 i m 180
65
100
n
n1
w
s
kg 3~
158
125
97
9
19.0
electropumps with peripheral impeller recommended for industrial uses
RANGEOFPERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 90 m
GUARANTEE YEARS according our general terms of sale. GUARANTEE 12YEAR subject totoour general terms of sale. CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 8 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
●
EXECUTIONANDSAFETYSTANDARDS
●
●
●
EN 60034-1 IEC 34-1 CEI 2-3
● ●
overload protector built into the winding.
USESANDINSTALLATIONS They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made.MADE OF HIGH-PERFORMANCE TECHNOPOLYMER WITH FRONT COVERS ON THE BRASS IMPELLERS; THIS OFFERS A SURE GUARANTEE AGAINST RUST AND OXIDATION. DUE TO THESE CHARACTERISTICS THEY ARE RECOMMENDED FOR USE IN THE INDUSTRIAL SECTOR, FOR EXAMPLE COOLING, CONDITIONING, IRONING SYSTEMS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
PUMP BODY: high-performance technopolymer, with threaded metal insert ISO 228/1, inserted in the inlets, alllowing a sure conneection of the pipes without damaging the pump body. PUMP BODY COVER: brass . LANTERN (patent nº 1289150): aluminium with front shim disk in brass; eliminates blockage of the impeller after long periods of inactivity. IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PQAm: single-phase 230 V - 50 Hz with condenser and thermal
● ●
PQA: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒
pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal protection IP 55 other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Head H
(metres)
PQA90
PQA82 PQA80 PQA72 PQA70
PQA60
Flow rate Q
TYPE Single-phase PQAm 60 PQAm 70 PQAm 72 PQAm 80 PQAm 82 PQAm 90
POWER
Three-phase PQA 60 PQA 70 PQA 72 PQA 80 PQA 82 PQA 90
kW
0.37 0.55 0.55 0.75 0.75 0.75
m3/h
Q
HP
0
0.1
0.3
0.6
0.9
1.2
1.5
1.8
1.9
2.3
2.7
3.0 50
l/min
0
2
5
10
15
20
25
30
32
38
45
0.50 0.75 0.75 H metres 1 1 1
40 65 65 70 70 90
38 62 66 86
35 58 62 62 66 79
29 52 57 56 61 68
23.5 45.5 52 49.5 56 56.5
18 39.5 47 43 51 45.5
12.5 33 42 37 46 34
7 27 37.5 31 41.5 23
5 24 35.5 28 39.5 18.5
16.5 29.5 20.5 37.5 5
8 22.5 12 26.5
Q = Flow rate H = Total manometric head
18 22
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
i
h1
h3
h
DN1
h2
DN2
n1 n
s a
TYPE Single-phase Three-phase PQAm 60 PQA 60 PQAm 70 PQA 70 PQAm 72 PQA 72 PQAm 80 PQA 80 PQAm 82 PQA 82 PQAm 90 PQA 90
w
m
INLETS DN1
DN2
1/2" 1/2" 1/2" 1" 1/2" 1" 1/2"
1/2" 1/2" 1/2" 1" 1/2" 1" 1/2"
a 25 28 28 28 28 28 27
f 226 258 258 258 258 258 257
h 152 179 179 179 179 179 179
h1 103 116.5 121 116.5 121 121 121
DIMENSIONS mm h2 h3 i 33 136 72.5 72.5 32.5 149 72.5 30 151 83 32.5 149 72.5 30 151 83 35 156 76
kg m 80 90 90 90 90 90
n 120 138 138 138 138 138 138
n1 100 112 112 112 112 112 112
w 55 62 62 62 62 62
s 7 7 7 7 7 7 7
1~ 4.8 10.3 10.4 10.5 10.5 10.4 10.4
3~ 4.8 9.3 9.4 9.5 9.5 9.4 9.4
electropump with peripheral impeller recommended for industrial uses
RANGEOFPERFORMANCE Flow rate up to 10 l/min (0.6 m3/h) Head up to 42 m
GUARANTEE YEARS according our general general terms of sale. subject totoour terms of sale. GUARANTEE 1 2YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 8 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
●
● ● ●
EXECUTIONANDSAFETYSTANDARDS
●
EN 60034-1 IEC 34-1 CEI 2-3 ●
PUMP BODY: brass, with threaded inlets ISO 228/1. LANTERN (patentnº 1289150): aluminium with front shim disk in brass; eliminates blockage of the impeller after long periods of inactivity IMPELLER: brass, of the type with radial peripheral vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - EPDM. ELECTRIC MOTOR: the pump is coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PVm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. PV: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL
USESANDINSTALLATIONS
●
They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials
EXECUTIONSONREQUEST
of which the pump is made. THE CONSTRUCTIVE CHARACTERISTICS OF THIS PARTICULARLY COMPACT BRASS PUMP ARE A SURE GUARANTEE AGAINST RUST AND OXIDATION. THESE CHARACTERISTICS MAKE IT SUITABLE FOR TRANSFERRING LIQUIDS IN THE MECHANICAL PROCESSING SECTOR, FOR CONTROLLING THE TEMPERATURE OF MOULDS, COOLING, CONDITIONING AND FOR BEVERAGE DISPENSING MACHINES. The pump must be installed in enclosed places, or at least protected against inclement weather.
⇒ ⇒ ⇒ ⇒ ⇒
pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanikcal seal pump body rotated 90° in anti-clockwise direction protection IP 55 other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0 40
0.5
0
1
1.5
0.5
2
1
2.5
1.5
2
120
PV55
35
100
Head H
(metres)
30
25
80
20 60
15 40
10 20 5
0
0
1
2
0
3
0.1
POWER
Three-phase PV 55
5
0.2
TYPE Single-phase PVm 55
4
kW
0.18
Q
HP
6
7
0.3
8
0.4
Flow rate Q
9
0
10
0.5
0.6
m3/h
0
0.12
0.18
0.24
0.30
0.36
0.42
0.48
0.54
0.60
l/min
0
2
3
4
5
6
7
8
9
10
42
35
31
28
25
21.5
18
14.5
11
8
0.25 H metres
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
i DN1
f
h1
h3
h
h2
DN2
s a
TYPE
w
n1 n
m
INLETS
DIMENSIONS mm
kg
Single-phase
Three-phase
DN1
DN2
a
f
h
h1
h2
h3
i
m
n
n1
w
s
1~
3~
PVm 55
PV 55
1/4"
1/4"
10
203
141
56
42
98
25
72
110
90
67
6
4.1
4.1
centrifugal electropumps
RANGEOFPERFORMANCE Flow rate up to 160 l/min (9.6 m3/h) Head up to 58 m
GUARANTEE 2 YEARS according to our general terms of sale. GUARANTEE 1 YEAR subject to our general terms of sale. CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Liquid temperature up to + 40°C in the CPX version (with technopolymer impeller) Environment temperature up to + 40°C
●
EXECUTIONANDSAFETYSTANDARDS
●
● ● ● ●
EN 60034-1 IEC 34-1 CEI 2-3 USESANDINSTALLATIONS
●
They are recommended for pumping clean water and liquids that are
●
chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY AND ABSENCE OF MAINTENANCE THEY ARE WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR FOR DISTRIBUTION WATER IN COMBINATION WITH SMALL OR MEDIUM AUTOCLAVES, FOR TRANSFER IN GENERAL, FOR IRRIGATING GARDENS. The pumps must be installed in enclosed places, or at least protected against inclement weather.
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: stainless steel AISI 304 or cast iron on higher powered models. BRASS IMPELLER: CP 100-CP 132-CP 152-CP 150-CP 170-CP 190-CP 200 STAINLESS STEEL IMPELLER: CP 130-CP 158 MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. CPm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. CP: three-phase230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒
electropump with impeller in technopolymer (CPm...X - CP...X) special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
CP200
Head H
(metres)
CP190
CP170 CP158 CP152
CP170M
CP150
CP130
CP132A CP132B
CP100
Flow rate Q
TYPE Single-phase CPm 100 CPm 130 CPm 132B CPm 132A CPm 152 CPm 150 CPm 158 CPm 170 CPm 170M CPm 190 –––
POWER
Three-phase CP 100 CP 130 CP 132B CP 132A CP 152 CP 150 CP 158 CP 170 CP 170M CP 190 CP 200
kW
Q
HP
0.25 0.37 0.45 0.60 0.55 0.75 0.75 1.1 1.1 1.5 2.2
m3/h
0
0.6
1.2
1.8
2.4
3.0
l/min
0 16 23 20 23 33 29.5 36 41 36 50 58
10 15 22 –– –– 32 –– 34 –– –– –– ––
20 14 21 18 22 31 29 33.5 –– –– –– ––
30 12.5 20 17 21.5 29.5 28.5 33 38 35 46 55
40 11 19 16 21 28.5 28 32.5 37 34.5 44.5 54.5
50 60 70 80 9 7 18 17 15.5 14 15 13.5 12 10.5 20 19 18 17 27 25 23 19 27.5 26.5 26 24.5 31.5 30 28.5 27 36 35 33.5 32 33.5 33 32 31 43 41.5 40 38 53.5 52 51 49.5
0.33 0.50 0.60 0.85 0.75 1 H metres 1 1.5 1.5 2 3
Q = Flow rate H = Total manometric head
3.6
4.2
4.8
5.4
6.0
6.6
90
100 110
7.2
7.8
8.4
9.0
120 130
140
150 160
9 16
7 14
12
9
23 25 30 30 36 48
21
18
15
27.5 25 22 29 28 26.5 25 23 34.5 32.5 30.5 28 26 46 44.5 42.5 40.5 38.5
21
9.6
19
36
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS n
f a
h1
DN1
h
h2
DN2
s
w TYPE Single-phase Three-phase CPm 100 CP 100 CPm 130 CP 130 CPm 132B CP 132B CPm 132A CP 132A CPm 152 CP 152 CPm 150 CP 150 CPm 158 CP 158 CPm 170-170M CP 170-170M CPm 190 CP 190 ––– CP 200
n1
INLETS DN1
DN2
1" 1" 1" 1" 1" 1" 1" 1" 11/4" 1/4"" 111/4 11/4"
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
a 34 42 42 42 42 42 42 42 51 51 51.5
f 247 259 259 259 266/259 285 285 285 367 338 364 338
h 187 205 205 205 240 240 240 260 290 290 290
DIMENSIONS mm h1 h2 n 77 110 148 82 123 165 123 165 82 123 165 82 123 165 92 148 190 92 148 190 92 148 190 110 150 206 115 175 242 242 115 175 115 175 242
kg n1 118 135 135 135 135 160 160 160 165 206 206 206
w 45 41 41 41 38 38 38 44.5 32.5 32.5 32.5
s 10 10 10 10 10 10 10 10 11 11 11
1~ 6.8 7.8 8.0 8.4 11.5 12.5 12.1 19.2 25.0 -
3~ 6.9 7.6 7.5 8.1 11.5 11.3 11.6 18.5 24.2 25.5
enbloc centrifugal electropumps with threaded inlets
Electropumps with highyield motor to reduce energy consumption
RANGEOFPERFORMANCE Flow rate up to 900 l/min (54 m3/h) Head up to 75 m
GUARANTEE 1 YEAR subject to our general terms of sale. GUARANTEE 2 YEARS according to our general terms of sale.
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3 ● ●
USESANDINSTALLATIONS
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: cast iron. IMPELLER: brass for pumps CP 220, CP 230. IMPELLER: cast iron for pumps CP 250. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, with high yield (class “EFF1"), silent-running, closed, with external ventilation, suitable for continuous duty. CP: three-phase 230/400 V - 50 Hz up to4 kW. 400/690 V - 50 Hz from 5.5 to 11 kW. INSULATION: class F. ● PROTECTION IP 44. REGISTERED MODEL nº 72753 PATENTED ELECTRIC MOTOR
They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY AND ABSENCE OF MAINTENANCE THEY ARE WIDELY USED IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL SECTORS, FOR SUPPLYING WATER, FOR CONDITIONING OR COOLING SYSTEMS, FOR IRRIGATION, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒
pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal protection IP 55 other voltages or frequency 60 Hz
PERFORMANCE RANGE AT n= 2900 1/min
0 0
20
40
20
60
40
80 60
100
120
80
140
100
160
120
180
140
200 160
220
240
180
80
feet 250
70
200
60
150
40
Head H
(metres)
50
100
30
CP 220 CP 250 20
50
CP 230 10
0
0
0
100
0
6
200 12
300
400
500
600
700
800
900
18
24
30
36
42
48
54
Flow rate Q
l/min
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
CP220AH 50
CP220A
54
56
57 58
H (feet)
CP220B
CP220C
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
(metres)
Ρ=60%
AH
P2 (HP)
Absorbed power P 2
A B C
Flow rate Q
TYPE Three-phase CP 220C CP 220B CP 220A CP 220AH
POWER kW
HP
2.2 3 4 5.5
3 4 5.5 7.5
Q = Flow rate H = Total manometric head
Q
m3/h l/min
H metres
0
3
6
12
18
24
27
0
50
100
200
300
400
450
32 38 49 52
31.5 37.5 48.5 51.5
31 37 48 51
30 36 46 49
28 33.5 43.5 47
24 29 39.5 44
21 25 36 42
Tolerance of the performance curves according to EN ISO 9906 App. A.
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase CP 230C CP 230B CP 230A
POWER kW
HP
3 4 5.5
4 5.5 7.5
Q = Flow rate H = Total manometric head
Q
m3/h
0
6
12
18
24
30
36
42
48
51
54
l/min
0
100
200
300
400
500
600
700
800
850
900
30 39 46
29.5 38.5 45.5
28.5 38 44.5
H metres
27 25 22 19.5 15.5 11.5 9 36 34 31 28 24 18.5 15 13 42 40 37 32.5 27.5 21.5 18 15 Tolerance of the performance curves according to EN ISO 9906 App. A.
P2 (HP)
Absorbed powerP 2
(kW)
NPSH
NPSH
(feet)
(metres)
HeadH
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase CP 250C CP 250B CP 250A CP 250CR CP 250BR CP 250AR
POWER kW
7.5 9.2 11 7.5 9.2 11
HP
Q
m3/h l/min
10 12.5 15 H metres 10 12.5 15
Q = Flow rate H = Total manometric head
0
6
12
0
100
200
57 66 74 57 66 74
56 65 73 56 65 73
54.5 62.5 71 54.5 62.5 71
18
24
30
300
400
500
52.5 60 68 52.5 60 68
49.5 57 65 49.5 57 65
46 53 61 46 53 61
36
42
48
54
600
700
800
900
41.5 49 57 41.5 49 57
35.5 43.5 51 35.5 43.5 51
30 37.5 45 30 37.5 45
24 30 37 24 30 37
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f n
a
h1
DN1
h
h2
DN2
s n1 n2
w
TYPE
INLETS
DIMENSIONS mm
kg
DN1
DN2
a
f
h
h1
h2
n
n1
n2
w
s
CP 220C
2"
2"
70
459
328
136
192
273
190
250
40
14
37.7
CP 220B
2"
2"
70
459
328
136
192
273
190
250
40
14
38.6
CP 220A
2"
2"
70
459
328
136
192
273
190
250
40
14
41.0
CP 220AH
2"
2"
70
505
328
136
192 192
273
190
250 250
40 40
14
47.6
CP 230C
2"
2"
70
328
136
192
273
190
250
40
14
37.7
CP 230B
2"
2"
70
459 459 459
328
136
192
273
190
250
40
14
41.3
CP 230A
2"
2"
70
505
328
136
192
273
190
250
40
14 14
47.6
CP 250C
2"
2"
65
507
392
160
232
322
230
294
45
14
74.0
CP 250B
2"
2"
65
392
160
232
322
230
294
45
14
96.0
CP 250A
2"
2"
65
571 571 571
3"
92
534
232 232 232
322 322 322
230 230 230
294 294 294
45 45 45
103.0
4"
160 160 160
14
CP 250CR
392 392 392
14
78.0
CP 250BR
4" 4"
3" 3"
92
392
160
232
322
230
294
45
14
100.0
CP 250AR
4"
3"
92
598 598 598
392
160
232
322
230
294
45
14
107.0
Three-phase
2"
2"
normalised centrifugal electropumps“EN 733 - DIN 24255”
RANGEOFPERFORMANCE Flow rate up to 250 l/min (15 m3/h) Head up to 57 m
GUARANTEE 2 YEARS according to our general terms of sale. subject to our general terms of sale. GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3
●
PUMP BODY: cast iron, made according to standards EN 733 DIN 24255 and UNI 7467- NF E-44-111, with threaded inlets ISO 228/ 1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. CPm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding up to 1.5 kW. CP: three-phase 230/400 V - 50 Hz. INSULATION : class F. ● PROTECTION: IP 44.
USESANDINSTALLATIONS
EXECUTIONSONREQUEST
They are recommended for pumping clean water and liquids that are
⇒ ⇒
chemically non aggressive for the materials of which the pump is made. THE PUMPS IN THIS SERIES ARE MADE ACCORDING TO STANDARDS EN 733 - DIN 24255 AND THEY ARE SPECIFICALLY USED IN THE CIVIL, INDUSTRIAL OR AGRICULTURAL SECTORS WHERE THEIR CHARACTERISTICS OF STURDINESS AND RELIABILITY CAN BE BEST APPRECIATED. The pumps must be installed in enclosed places, or at least protected against inclement weather.
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
CP25/200A 42
(metres)
45 47
CP25/200B
η=49% CP25/160AR
47
50
53
45
Head H
CP25/160A
42
η=56%
CP25/160B
53 50
Flow rate Q
TYPE Single-phase CPm 25/160B CPm 25/160A ––– CPm 25/200B –––
POWER
Three-phase CP 25/160B CP 25/160A CP 25/160AR CP 25/200B CP 25/200A
Q
m3/h
0
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.5
8.4
0 33 38 42 49 57
50 32.5 37 41 48 56
60 32 36.8 41 47.5 55.8
70 31.5 36.5 40.5 47 55.5
80 31 36 40 46.5 55
90 30.5 35.5 39.5 45.5 54.5
100 30 35 39 45 53.5
110 29 34 38 44 53
125 28 33 37 43 52
140 26.5 31.5 36 41 50.5
kW
HP
l/min
1.1 1.5 2.2 2.2 3
1.5 2 3 3 4
H metres
Q = Flow rate H = Total manometric head
10.8
12.0
13.2
15.0
160 180 24 21.5 29.5 27 34 31 38.5 36 48.5 46
9.6
200 18 24 28 32 43.5
220
250
20 24 28 40
22 33
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
n
a
h1
DN1
h
h2
DN2
w1
TYPE Single-phase Three-phase CPm 25/160B CP 25/160B CPm 25/160A CP 25/160A ––– CP 25/160AR CPm 25/200B CP 25/200B ––– CP 25/200A
w2
s
n1
INLETS DN1
DN2
11/2" 11/2" 11/2" 1/2" 11/2" 11/2"
1" 1" 1" 1" 1" 1"
a 56 56 56 56 60 60 60
f 360 386 380 384/359 384
h 260 260 260 260 305 305 305
h1 105 105 105 125 125 125
DIMENSIONS mm h2 n 155 206 155 206 155 206 180 252 252 180 180 252
kg n1 150 150 150 210 210 210
w1 27.5 27.5 27.5 23.5 23.5 23.5
w2 27.5 27.5 27.5 39.5 39.5 39.5
s 10 10 10 10 11 11 11
1~ 20.7 21.7 31.0 -
3~ 18.7 21.0 21.8 28.6 30.7
centrifugal electropumps medium flow rates
RANGEOFPERFORMANCE Flow rate up to 600 l/min (36 m3/h) Heads up to 39 m
GUARANTEE 2 YEARS according to our general terms of sale. subject to our general terms of sale. GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. HFm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. HF: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONS ON REQUEST USESANDINSTALLATIONS THE HF SERIES IS RECOMMENDED FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL FIELD. THE HIGH YIELDS REACHED AND THE POSSIBILITY OF CONTINUOUS DUTY MAKE ITS USE ADVANTAGEOUS FOR IRRIGATION WITH FLOWING AND SPRINKLING WATER, FOR DRAWING WATER FROM LAKES, RIVERS, WELLS, OR FOR VARIOUS INDUSTRIAL USES CHARACTERISED BY THE NEED TO ACHIEVE CONSIDERABLE FLOW RATES IN RELATION TO MEDIUM-LOW HEADS. The pumps must be installed in enclosed places, or at least protected against inclement weather.
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
HF70A
HF70B
Head H
(metres)
HF60
HF5AM HF51A
HF5BM
HF51B
HF50A
HF5A HF5B HF5C
HF50B
Flow rate Q
TYPE Single-phase HFm 50B HFm 50A HFm 51B HFm 51A HFm 60 HFm 70B ––– HFm 5C HFm 5B HFm 5A HFm 5BM HFm 5AM
POWER
Three-phase HF 50B HF 50A HF 51B HF 51A HF 60 HF 70B HF 70A HF 5C HF 5B HF 5A HF 5BM HF 5AM
kW
0.37 0.55 0.60 0.75 1.1 1.5 2.2 0.60 0.75 1.1 1.1 1.5
HP
Q
m3/h l/min
0.50 0.75 0.85 1 1.5 2 H metres 3 0.85 1 1.5 1.5 2
0
3
6
9
0
50
100
9 12 18.2 21.2 29 33 39 12.5 13.7 14.5 20.2 22.5
8.5 11.5 17.2 20.2 28 32 38 ––– ––– ––– ––– –––
8.2 11.2 16 19 26.5 30.5 36.5 12 13.2 13.8 19.2 22
Q = Flow rate H = Total manometric head
12
15
18
21
24
30
36
150
200
250
300
350
400
500
600
7.5 10.6 14 17 24.5 28.5 34.5 11.7 13 13.5 19 21.5
6.3 9.6 11.5 14.5 22 26 32 11 12.5 13.2 18 21
4.9 8 9 11.6 18.5 22.5 28.5 10.2 11.6 12.6 17 20
2.8 6 5.4 8.4 15 19 25 9.2 10.5 11.8 16 18.5
8 9.2 10.5 14 16.6
6.5 8 9.2 12 14.5
5 6.5 7.5 10
3
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS f a
n
h1
DN1
h
h2
DN2
w TYPE Single-phase Three-phase HFm 50B HF 50B HFm 50A HF 50A HFm 51B HF 51B HFm 51A HF 51A HFm 60 HF 60 HFm 70B HF 70B ––– HF 70A HFm 5C HF 5C HFm 5B HF 5B HFm 5A HF 5A HFm 5BM HF 5BM HFm 5AM HF 5AM
n1 INLETS DN1
DN2
11/2" 11/2" 11/2" 11/2" 1/2" 11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 2"
11/2" 11/2" 11/2" 11/2" 1/2" 11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 2"
a 45 45 45 45 45 48.5 48.5 48.5 48.5 60 60 60 60 51 51 51
f 276 283/276 300 300 300 347 373 367 332 332 332 360 386 380/360
h 200 200 200 225 225 225 269 269 269 238 238 238 260 260 260
DIMENSIONS mm h1 h2 n 82 118 165 82 118 165 82 118 165 92 133 190 92 133 190 92 133 190 114 155 216 114 155 216 114 155 216 114 155 216 97 141 196 97 141 196 97 141 196 97 141 196 110 150 206 110 150 206 110 150 206
s kg n1 135 135 135 160 160 160 171 171 171 171 160 160 160 160 160 160
w 11 1 4 4 4 12 12 12 14 14 14 14 11 1
s 10 10 10 10 10 12 12 12 11 11 11 11 11
1~ 8.3 8.9 15.5 13.0 20.0 22.2 15.3 15.1 15.5 20.3 22.2
3~ 8.2 8.4 15.1 12.1 19.3 21.6 22.8 14.2 14.3 15.2 19.5 21.8
centrifugal electropumps high flow rates
RANGEOFPERFORMANCE Flow rate up to 1800 l/min (108 m3/h) Head up to 24.5 m
GUARANTEE 1 YEAR subject to our general terms of sale. GUARANTEE 2 YEARS according to our general terms of sale.
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. HFm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. HF: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONS ON REQUEST USESANDINSTALLATIONS THE HF SERIES IS RECOMMENDED FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL FIELD. THE HIGH YIELDS REACHED AND THE POSSIBILITY OF CONTINUOUS DUTY MAKE ITS USE ADVANTAGEOUS FOR IRRIGATION WITH FLOWING AND SPRINKLING WATER, FOR DRAWING WATER FROM LAKES, RIVERS, WELLS, OR FOR VARIOUS INDUSTRIAL USES CHARACTERISED BY THE NEED TO ACHIEVE CONSIDERABLE FLOW RATES IN RELATION TO MEDIUM-LOW HEADS. The pumps must be installed in enclosed places, or at least protected against inclement weather.
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
HF8A HF30A HF8B
Head H
(metres)
HF6A-6AR
HF20A HF30B
HF20B HF6B-6BR
HF6C-6CR
HF4
100
Flow rate Q
TYPE Single-phase HFm 4 HFm 6C HFm 6B ––– HFm 6CR HFm 6BR ––– ––– ––– ––– ––– ––– –––
POWER
Three-phase HF 4 HF 6C HF 6B HF 6A HF 6CR HF 6BR HF 6AR HF 8B HF 8A HF 20B HF 20A HF 30B HF 30A
kW
HP
0.75 1.1 1.5 2.2 1.1 1.5 2.2 3 4 3 4 5.5 7.5
1 1.5 2 3 1.5 2 3 4 5.5 4 5.5 7.5 10
m3/h
Q l/min
0
0 10 11.9 14.7 18.5 11.9 14.7 H metres 18.5 21.5 24.5 16 19 18 23
12
18
24
30
36
42
48
200 9.3 11.7 14.5 18.1 11.7 14.5 18.1 21 24 -
300 8.7 11.3 14 17.8 11.3 14 17.8 20.7 23.5 -
400 8 10.7 13.5 17.2 10.7 13.5 17.2 20 23 15.5 18.5 -
500 7 10.2 12.8 16.8 10.2 12.8 16.8 19.5 22.5 15.4 18.4 -
600 6 9.2 12 16 9.2 12 16 18.8 21.8 15.3 18.3 18 23
700 4.7 8 11 15 8 11 15 17.8 20.8 15.2 18.2 18 23
800 3 6.7 9.7 13.8 6.7 9.7 13.8 16.5 19.5 15 18 18 23
Q = Flow rate H = Total manometric head
54
60
66
72
84
96
102 108 120 132
900 1000 1100 1200 1400 1600 1700 1800 2000 2200 5 8.2 12.2 5 8.2 12.2 15 18.3 14.5 17.5 18 23
3 6.7 10.5 3 6.7 10.5 13.5 16.8 14 17 18 23
5 8.3
6
5 8.3 6 11.2 9 15 13 13 12 9 4.8 2 16.2 15.2 12 7.8 5 2 17.5 17 16.5 15.5 15 14.5 13 22.5 22.5 22.5 22 21.5 21 19.5
18
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS f
n
a
h1
DN1
h
h2
DN2
w TYPE Single-phase Three-phase HFm 4 HF 4 HFm 6C HF 6C HFm 6B HF 6B ––– HF 6A HFm 6CR HF 6CR HFm 6BR HF 6BR ––– HF 6AR ––– HF 8B ––– HF 8A ––– HF 20B ––– HF 20A ––– HF 30B ––– HF 30A
n1
INLETS DN1
DN2
21/2" 3" 3" 3" 3" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"
21/2" 3" 3" 3" 3" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"
a 55 68 68 68 68 70 70 70 70 80 80 80 80 80 82 82 82
f 323 385 405/385 411 405 387 407/387 413 407 429 462 429 462 585 585 585
h 240 312 312 312 312 312 312 312 312 312 312 312 370 370 370
DIMENSIONS mm h1 h2 n 97 143 190 120 192 240 120 192 240 120 192 240 120 192 240 120 192 240 120 192 240 120 192 240 132 180 245 132 180 245 132 180 245 132 180 245 132 180 245 160 210 292 160 210 292 160 210 292
s kg n1 155 190 190 190 190 190 190 190 190 190 190 190 212 212 212
w 0 6 6 6 66 6 6 30 30 30 30 30 30 30
s 10 12 12 12 12 12 12 12 14 14 14 14 14 14 14
1~ 15.6 28.1 29.1 29.7 32.0 -
3~ 14.2 26.2 28.5 29.4 29.2 31.4 32.3 36.1 41.0 35.3 40.5 60.9 65.2
centrifugal electropumps with flanged inlets
RANGEOFPERFORMANCE Flow rate up to 1200 l/min (72 m3/h) Head up to 22.5 m
GUARANTEE 2 YEARS according ourgeneral general terms of sale. subject to to our terms of sale. GUARANTEE 1 YEAR
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 40°C
●
CONSTRUCTIONCHARACTERISTICS
EXECUTIONANDSAFETYSTANDARDS
PUMP BODY: cast iron, with threaded suction and delivery FLANGES ISO 228/1. IMPELLER: brass, of the type with centrifugal radial flow. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. NFm: single-phase 230 V - 50 Hz with condenser and thermal
EN 60034-1 IEC 34-1 CEI 2-3
overload protector built into the winding. NF: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
●
● ● ●
●
EXECUTIONS ON REQUEST USESANDINSTALLATIONS THE NF SERIES, FROM THE POINT OF VIEW OF BOTH PERFORMANCE AND MECHANICAL DIMENSIONS, HAS BEEN EXPRESSLY DESIGNED FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL FIELD. THE HIGH YIELDS REACHED AND THE POSSIBILITY OF CONTINUOUS DUTY RECOMMEND ITS USE FOR IRRIGATION WITH FLOWING AND SPRINKLING WATER, FOR DRAWING WATER FROM LAKES, RIVERS, WELLS, AND FOR TRANSFER IN GENERAL. The pumps must be installed in enclosed places, or at least protected against inclement weather.
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
NF129A
(metres)
NF129B
NF130A
NF130B
NF128 AR NF128A NF128B
Head H
NF130C
Flow rate Q
TYPE Single-phase NFm 128B NFm 128A NFm 128AR NFm 129B NFm 129A NFm 130C NFm 130B –––
POWER
Three-phase NF 128B NF 128A NF 128AR NF 129B NF 129A NF 130C NF 130B NF 130A
kW
0.60 0.75 1.1 1.1 1.5 1.1 1.5 2.2
Q
HP
m3/h l/min
0.85 1 1.5 1.5 H metres 2 1.5 2 3
0
6
9
12
0
100
150
200
250
11.7 13 13.5 19 21.5 –– –– ––
11 12.5 13.2 18 21 11.7 14.5 18.1
10.2 11.6 12.6 17 20 11.5 14.2 18
12.5 12 13.7 13.2 14.5 13.8 20.2 19.2 22.5 22 11.9 –– 14.7 –– 18.5 ––
15
Q = Flow rate H = Total manometric head
18
21
24
30
36
42
48
54
300 350
400
500
600
700
800
900 1000 1100 1200
9.2 10.5 11.5 16 18.5 11.3 14 17.8
8 9.2 10.5 14 16.6 11.1 13.7 17.5
6.5 8 5 9.2 6.5 12 7.5 14.5 10 10.7 10.2 13.5 13.2 17.2 16.8
60
66
72
3
9.1 12 16
8 11 15
6.7 5 9.7 8.2 13.8 12.2
3 6.7 5 10.5 8.3
6
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
n
f a
h1
DN1
h
h3
h2
DN2
w1
TYPE Single-phase Three-phase NFm 128B NF 128B NFm 128A NF 128A NFm 128AR NF 128AR NFm 129B NF 129B NFm 129A NF 129A NFm 130C NF 130C NFm 130B NF 130B ––– NF 130A
w2
s
n1
INLETS DN1
DN2
2" 2" 2" 2" 2" 2" 3" 3" 3" 3"
2" 2" 2" 2" 2" 2" 3" 3" 3" 3"
a 65 65 65 56 56 56 71 71 71
f 344 344 344 344 372 398 392/372 390 416 410/390 410
h 271 271 271 276 276 276 320 320 320
h1 97 97 97 110 110 110 120 120 120
DIMENSIONS h2 h3 167 264 167 264 167 264 167 264 159 269 159 269 159 269 193 313 193 313 193 313 193 313
mm n 196 196 196 206 206 206 240 240 240
n1 160 160 160 160 160 160 190 190 190
w1 8 8 8 1 1 1 6 6 6
kg* w2 s 1~ 3~ 60 12 19.8 17.1 60 12 18.3 17.0 60 12 18.3 18.3 62 11 23.3 22.7 62 11 62 11 26.0 24.6 66 12 33.5 31.5 12 34.4 33.4 66 66 12 34.6 (*weight with counterflanges)
centrifugal electropumps with open impeller
Centrifugal pumps made of cast iron, equipped with open impeller, ideal for transferring liquids containing impurities
RANGEOFPERFORMANCE Flow rate up to 350 l/min (21 m3/h) Head up to 20 m
accordingto to our general terms of sale. of sale. GUARANTEE YEARS subject our general terms GUARANTEE 12YEAR
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Liquid temperature up to + 40°C in the NGAX version (with technopolymer impeller) Environment temperature up to + 40°C Passage of solid bodies Ø 10 mm
● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3 USESANDINSTALLATIONS They are recommended for pumping water and liquids that are chemically non aggressive for the materials of which the pump is made. THE CONSTRUCTIVE SOLUTION OF THE OPEN IMPELLER ALLOWS PUMPING OF LIQUIDS RELATIVELY LOADED WITH IMPURITIES WITHOUT RISK OF CLOGGING THE IMPELLER. FOR THIS CHARACTERISTIC THE PUMPS IN THE NGA SERIES ARE SPECIFICALLY USED IN INDUSTRY, FOR THE TRANSFER OF WATER FROM CANALS, RIVERS, RESERVOIRS, TANKS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: stainless steel AISI 304. OPEN IMPELLER: stainless steel AISI 316. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. NGAm: single-phase 230V - 50 Hz with condenser and thermal overload protector built into the winding. NGA: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒
electropumps with impeller in technopolymer (NGAm...X - NGA...X) special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
NGA1A
Head H
(metres)
NGA1B
Flow rate Q
TYPE Single-phase NGAm 1B NGAm 1A
POWER
Three-phase NGA 1B NGA 1A
kW
0.55 0.75
m3/h
0
3
6
9
12
15
18
19.5
21
l/min
0
50
100
150
200
250
300
325
350
0.75 H metres 1
18
17
16
14.5
13
10.5
8
6
20
19.5
18
16.5
15
12.5
10
8
Q
HP
Q = Flow rate H = Total manometric head
6
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
n
a
h1
DN1
h
h2
DN2
w
TYPE Single-phase Three-phase NGAm 1B NGA 1B NGAm 1A NGA 1A
s
n1
INLETS DN1
DN2
11/2" 11/2" 11/2" 11/2" 11/2" 11/2"
a 41 41 41
f 297 297 297
h 227 227 227
DIMENSIONS mm h1 h2 n 92 135 190 135 190 92 92 135 190
kg n1 160 160 160
w 50 50 50
s 10 10 10
1~ 12.7 12.8
3~ 11.8 11.9
normalised centrifugal electropumps “EN 733 - DIN 24255”
Electropumps equipped with new motors (patented) with high yield, class "EFF1" for maximum energy saving.
RANGEOFPERFORMANCE Flow rate up to 6000 l/min (360 m3/h) Head up to 95 m
GUARANTEE 2 YEARS according to our general terms of sale. subject to our general terms of sale. GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature from -10°C to + 90°C Environment temperature from -10°C to + 40°C Max. pressure in the pump body 10 bar (PN10)
● ● ●
EXECUTIONANDSAFETYSTANDARDS ●
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. THIS SERIES IS INDICATED FOR SUPPLYING AND MOVING WATER, IN COOLING, HEATING, CIRCULATING AND CONDITIONING SYSTEMS, FOR FIRE FIGHTING, IRRIGATION, IN THE CIVIL, INDUSTRIAL AND AGRICULTURAL FIELD. The realisation according to standards EN 733 - DIN 24255 ensures that the dimensions comply with those standards. The constructive form allows the pump body to be removed without disconnecting it from the pipes (back pull out). The pumps must be installed in enclosed places, or at least protected against inclement weather.
●
PUMP BODY: cast iron, dimensions according to standards EN 733 - DIN 24255 and UNI 7467-NF E-44-111, with flanged suction and delivery inlets and threaded steel counterflanges. PUMP BODY COVER: cast iron. IMPELLER: brass for models F32/160, F32/200, F40/160, F40/200, F50/125 e F50/160. IMPELLER: cast iron for models F40/250, F50/200, F50/250, F65/125, F 65/160, F65/200, F80/160, F100/160 MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, asynchronous type with high yield (class EFF1 for powers from 4 to 22 kW), silent-running, closed, with external ventilation, suitable for continuous duty. Fm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding (up to 1.5 kW). F: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 22 kW. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒ ⇒ ⇒
pump shaft in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal other voltages or frequency 60 Hz protection IP 55 for liquids with higher or lower temperatures for environments with higher or lower temperatures
RANGE OF PERFORMANCE AT n= 2900 1/min
30
50 30
100
250 100
50
500 250
750 500
1000 1250 750
1000
feet
100
300
F50/ 250
90 80
F40/ 250
70
250
200
F50/ 200
60
F40/ 200
F65/ 200
150
100
F80/ 160
50
F50/ 125
F100 /160
F65/ 125
F40/ 160
20
F65/ 160
F50/ 160
30
F32/ 160
Head H
(m)
F32/ 200H
40
F32/ 200
50
10 100 6
0
200 10
400
600
800 1000 50
Flow rate Q
2000 100
3000 150
200
4000 5000 l/min 250
300 350
DIMENSIONSANDWEIGHTS
n
f a
DN1
h
h2
DN2
h1
f
n1 n2
w1 w2
TYPE Single-phase Three-phase Fm 32/160C F 32/160C ––– F 32/160B ––– F 32/160A ––– F 32/200C ––– F 32/200B ––– F 32/200A ––– F 32/200BH ––– F 32/200AH ––– F 40/160C ––– F 40/160B ––– F 40/160A ––– F 40/200B ––– F 40/200A ––– F 40/250C ––– F 40/250B ––– F 40/250A ––– F 50/125C ––– F 50/125B ––– F 50/125A ––– F 50/160C ––– F 50/160B ––– F 50/160A ––– F 50/200C ––– F 50/200B ––– F 50/200A ––– F 50/200AR ––– F 50/250D ––– F 50/250C ––– F 50/250B ––– F 50/250A ––– F 50/250AR ––– F 65/125C ––– F 65/125B ––– F 65/125A ––– F 65/160C ––– F 65/160B ––– F 65/160A ––– F 65/200B ––– F 65/200A ––– F 65/200AR ––– F 80/160D ––– F 80/160C ––– F 80/160B ––– F 80/160A ––– F 100/160C ––– F 100/160B ––– F 100/160A
INLETS DN1
DN2
50 50 50 50 50 50 50 50 50 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 80 80 80 80 80 80 80 80 80 80 100 100 100 100 100 125 125 125 125
32 32 32 32 32 32 32 32 32 40 40 40 40 40 40 40 40 40 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 65 65 65 65 65 65 65 65 65 65 80 80 80 80 80 100 100 100 100
a 80 80 80 80 80 80 80 80 80 80 80 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 125 125 125 125 125 125 125
f 412 412 412 431 469 515 515 515 469 469 469 412 431 465 535 535 535 606 606 606 701 431 450 484 489 535 535 535 616 711 711 711 743 606 606 606 701 701 701 733 511 557 557 557 621 621 621 716 719 719 719 751 652 747 747 747 779 758 758 758 790
DN FLANGES mm
t mm
u mm
Nº
32 40 50 65 80 100 125
140 150 165 185 200 220 250
100 110 125 145 160 180 210
4
18
4 4 18 8 8 8 8
18 18 18 18
h 292 292 292 340 340 340 340 340 292 292 292 340 340 340 405 405 405 292 292 292 340 340 340 360 360 360 360 360 405 405 405 405 405 340 340 340 360 360 360 405 405 405 405 405 405 405 480 480 480
h1 132 132 132 160 160 160 160 160 132 132 132 160 160 160 180 180 180 132 132 132 160 160 160 160 160 160 160 160 160 180 180 180 180 180 160 160 160 160 160 160 180 180 180 180 180 180 180 200 200 200
DIMENSIONS h2 n 160 242 160 242 160 242 180 270 180 270 180 270 180 270 180 270 160 240 160 240 160 240 180 275 180 275 180 275 225 328 225 328 225 328 160 242 160 242 160 242 180 269 180 269 180 269 200 316 200 316 200 316 200 316 200 316 225 337 225 337 225 337 225 337 225 337 180 291 180 291 180 291 200 300 200 300 200 300 225 340 225 340 225 340 225 330 225 330 330 225 330 225 330 280 362 280 362 280 362
mm n1 190 190 190 190 190 190 190 190 190 190 190 190 212 212 212 250 250 250 190 190 190 212 212 212 212 212 212 212 250 250 250 250 250 212 212 212 212 212 212 212 250 250 250 250 250 250 250 280 280 280
s
kg* n2 240 240 240 240 240 240 240 240 240 240 240 240 265 265 265 320 320 320 240 240 240 265 265 265 265 265 265 265 320 320 320 320 320 280 280 280 280 280 280 280 320 320 320 320 320 320 320 360 360 360
DN
DN
u t
u t
HOLES Ø (mm)
w1 35 35 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 60 60 60
w2 35 35 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 35 35 35 35 35 35 35 35 35 35 35 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 47.5 60 60 60
s 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 18 18 18
1~ 39.2 -
3~ 38.4 39.2 42.6 52.1 57.0 63.0 48.5 52.8 41.2 43.9 50.5 61.4 65.9 108.0 115.0 132.0 41.4 44.2 50.5 55.5 60.5 65.0 105.3 121.7 134.2 145.7 111.0 118.0 135.0 148.0 159.5 62.0 67.7 72.0 100.0 107.0 123.0 128.0 141.5 153.0 112.5 129.5 142.5 154.0 141.2 153.7 165.2
(*weight with counterflanges)
DN1= 50 DN2= 32
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
F32/160A
55 60
F32/160B η=65.5%
H (feet)
(metres)
63
63
Head H
F32/160C 60
(kW)
NPSH
NPSH
(feet)
(metres)
55
P2 (HP)
Absorbed power P 2
A
B C
Flow rate Q
TYPE
POWER
Single-phase
Three-phase
kW
HP
Fm 32/160C ––– –––
F 32/160C F 32/160B F 32/160A
1.5 2.2 3
2 3 4
Q = Flow rate H = Total manometric head
m3/h
Q
l/min
H metres
0
6
9
12
15
18
21
24
27
400
450
0
100
150
200
250
300
350
25
24
23
21
19
16
13
31
30
29
28
26
23.5
20
16
38
37
36
34
32
30
27.5
24
20
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 50 DN2= 32
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Absorbed power P 2
A
P2 (HP)
B C
Flow rate Q
TYPE Three-phase F 32/200C F 32/200B F 32/200A
POWER kW
4 5.5 7.5
Q = Flow rate H = Total manometric head
5.5 7.5 10
m3/h
Q
HP
H metres
0
6
0 l/min 100
9
12
15
18
21
24
27
30
150
200
250
300
350
400
450
500
46
44
43
41.5
40
38
36
34
31.5
54
52
50.5
49
47
45
43
41
38.5
36
60
57
56.5
56
55
53
52
50
47
44
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 50 DN2= 32
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE
POWER
Three-phase
kW
F 32/200BH F 32/200AH
3 4
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
6
9
12
15
18
l/min
0
100
150
200
250
300
49
45
42
39
34
28
59
55
52
49
44
38
4 H metres 5.5
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 40
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase F 40/160C F 40/160B F 40/160A
POWER kW
2.2 3 4
Q = Flow rate H = Total manometric head
3 4 5.5
m3/h
Q
HP
H metres
0
6
0 l/min 100
9
12
15
18
24
30
36
42
150
200
250
300
400
500
600
700
27
27
26.5
26
25.5
25
22.5
19
14
32
32
31.5
31
30.5
30
27.5
24
20
38
38
37.8
37
36.5
36
33.5
30
26
20
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 40
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase F 40/200B F 40/200A
POWER kW
5.5 7.5
Q = Flow rate H = Total manometric head
m3/h
Q
HP
7.5 H metres 10
0 0
6
9
12
15
18
24
30
36
42
l/min 100
150
200
250
300
400
500
600
700
48
47
46.5
46
45.5
44.5
42
38
34
28
56
55
55
55 54.5 54 52.5 49.5 46 41 Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 40
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase F 40/250C F 40/250B F 40/250A
POWER kW
9.2 11 15
m3/h
Q
HP
12.5 15 H metres 20
Q = Flow rate H = Total manometric head
0
6
0 l/min 100
9
12
15
18
24
30
36
42 700
150
200
250
300
400
500
600
64
64
63.5
63
62.5
62
60
56.5
52.5
47
71
71
70.5
70
69.5
69
67
64
60
55
88
88
87.5
87
86.5
86
84
81
77
72
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 50
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE
POWER Q
m3/h
0
l/min
0
Three-phase
kW
HP
F 50/125C F 50/125B F 50/125A
2.2 3 4
3 18.5 4 H metres 21.5 5.5 24.5
Q = Flow rate H = Total manometric head
18
24
30
36
42
48
54
60
66
72 1200
300
400
500
600
700
800
900
1000
1100
17.5
17
16.5
15.5
14.8
13.5
12
10.5
8.2
6
20.7
20
19.5
18.8
17.8
16.5
15
13.5
11.2
9
23.5
23
22.5
21.8
20.8
19.5
18.3
16.8
15
13
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 50
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase F 50/160C F 50/160B F 50/160A
POWER kW
4 5.5 7.5
Q = Flow rate H = Total manometric head
5.5 7.5 10
m3/h
Q
HP
H metres
0
18
24
30
36
42
48
54
60
66
0 l/min 300
400
500
600
700
800
900
1000
1100
27
27
26.5
25
24.5
23
20
18.5
16
33
32
31.7
31
30
29
27
26
24
21
38
37
36.8
36.5
36
34
33
32
30
27
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 50
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase F 50/200C F 50/200B F 50/200A F 50/200AR
POWER kW
HP
11 15 18.5 22
15 20 25 30
Q = Flow rate H = Total manometric head
m3/h
24
36
48
60
72
84
96
102
108
l/min
400
600
800
1000
1200
1400
1600
1700
1800
44
44
44
42
39
36
33
30
Q
H metres
52
52
52
50
47
44
40
38
61
61
60.5
60
57
54
50
48
45
69
69
68.5
68
65
62
58
56
53
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 65 DN2= 50
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
100 F50/250AR
48
90
51
52
54
55
58
F50/250A
59
=59%
80
70
F50/250B
60
F50/250C
50
F50/250D
H (feet)
Head H
(metres)
60
57
40 54 52
30
(feet)
8 6
NPSH
4 2 0 25 AR A
20
P2 (HP)
Absorbed power P 2
(kW)
NPSH
(metres)
20
B
15 C
10
D
5
Flow rate Q
TYPE Three-phase F 50/250D F 50/250C F 50/250B F 50/250A F 50/250AR
0
18
24
30
36
42
48
54
60
l/min
0
300
400
500
600
700
800
900
1000
12.5 15 20 H metres 25 30
51
51
49
47
44
41
37
32
59
59
58
57
54
51
47
42
72
72
71
70
69
67
65
62
59
85
85
84
83
82
80
78
76
73
95
95
94
93
92
90
88
86
83
POWER kW
9.2 11 15 18.5 22
Q = Flow rate H = Total manometric head
HP
m3/h
Q
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 80 DN2= 65
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
78
F65/125A
83 87 87.5
87.5
H (feet)
87
F65/125B
F65/125C
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
(metres)
Ρ=88%
P2 (HP)
Absorbed power P 2
A
B C
Flow rate Q
TYPE Three-phase F 65/125C F 65/125B F 65/125A
POWER kW
4 5.5 7.5
Q = Flow rate H = Total manometric head
5.5 7.5 10
m3/h
Q
HP
H metres
0
36
48
60
72
84
96
108
120
132
0 l/min 600
2000
2200
800
1000
1200
1400
1600
1800
16
16
16
15.5
14.5
13.5
12.5
11
18
18
18
18
17
16.5
15.5
14.5
13
23
23
23
23
22.5
22.5
22
21
19.5
18
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 80 DN2= 65
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
60
65
70
75
78 80
F65/160B
Ρ=81%
F65/160C
H (feet)
(metres)
F65/160A
80
B
P2 (HP)
(kW)
A
Absorbed power P 2
NPSH
NPSH
(feet)
(metres)
Head H
78
C
Flow rate Q
TYPE
POWER
Three-phase
kW
F 65/160C F 65/160B F 65/160A
9.2 11 15
HP
m3/h
Q
l/min
12.5 15 H metres 20
Q = Flow rate H = Total manometric head
0
36
48
60
72
84
96
108
120
132
144
0
600
800
1000
1200
1400
1600
1800
2000
2200
2400
32
32
32
32
32
30
29
27
25
22
37
36.5
36.5
36
35.5
34
33
31
29
26
23
41
40.5
40.5
40
35.5
39
37.5
36
34
31
28
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 80 DN2= 65
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
60 60
F65/200AR
65
55
71 73 74
40
76 =79% 76
74 73
F65/200B
H (feet)
(metres)
45
Head H
50
F65/200A
71
30 8
(feet)
(metres)
35
6
NPSH
2 0 25 AR
20
A
P2 (HP)
Absorbed power P 2
(kW)
NPSH
4
B
15
10
5
Flow rate Q
TYPE Three-phase F 65/200B F 65/200A F 65/200AR
POWER kW
15 18.5 22
Q = Flow rate H = Total manometric head
20 25 30
m3/h
Q
HP
H metres
24
36
48
60
72
84
96
108
120
126
400 l/min 600
2100
800
1000
1200
1400
1600
1800
2000
45
45
45
45
44
42.5
41
38.5
35.5
51
51
51
51
50
49
47
44.5
41.5
40
57
57
57
57
56
55
53
50.5
47.5
46
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 100 DN2= 80
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE
POWER
Three-phase
kW
HP
F 80/160D F 80/160C F 80/160B F 80/160A
11 15 18.5 22
15 20 25 30
Q = Flow rate H = Total manometric head
m3/h
0
30
60
90
120
150
180
210
240
l/min
0
500
1000
1500
2000
2500
3000
3500
4000
25
25
25
24.5
23.5
21
18
14.5
10
30
30
30
29.5
28.5
26
23
19.5
15
35
35
35
34.5
33.5
31
28
24.5
20
40
40
40
39.5
38.5
36
33
29.5
25
Q
H metres
Tolerance of the performance curves according to EN ISO 9906 App. A.
DN1= 125 DN2= 100
P2 (HP)
Absorbed powerP 2
(kW)
NPSH
NPSH
(feet)
(metres)
HeadH
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE
POWER
Three-phase
kW
HP
F 100/160C F 100/160B F 100/160A
15 18.5 22
20 25 30
Q = Flow rate H = Total manometric head
m3/h
Q l/min H metres
0
60
120
180
240
270
300
330
360
5500
6000
0
1000
2000
3000
4000
4500
5000
28
28
25.5
22
17.5
15
12
32
32
30
27
22.5
19.5
17
13
35
35
34
31
27
24.5
22
18
15
Tolerance of the performance curves according to EN ISO 9906 App. A.
twin-impeller centrifugal electropumps
Twin-impellerpumpscharacterisedbyhigh yieldsandsilentrunningandadaptability tovarioususes.
RANGEOFPERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 112 m
GUARANTEE 2 YEARS subject our general termsus sale . GUARANTEE 1 YEAR subject totoour general termsofof sale. CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Liquid temperature up to + 40°C in the 2CPX version (with technopolymer impeller) Environment temperature up to+ 40°C
● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3
●
2CP 25/130N ● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. THEIR HIGH YIELDS AND ADAPTABILITY TO THE MOST VARIED, EVEN UNUSUAL APPLICATIONS, MAKE THEM THE IDEAL CHOICE IN THE DOMESTIC, CIVIL AND INDUSTRIAL FIELD; IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH AUTOCLAVES, FOR INCREASING PRESSURE IN THE MAINS, FOR FIRE-FIGHTING SETS.. The pumps must be installed in enclosed places, or at least protected against inclement weather.
MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, with high yield (class EFF1 for powers from 4 to 7.5 kW), silent-running, closed, with external ventilation, suitable for continuous duty. 2CPm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding (up to 1.5 kW). 2CP: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 7.5 kW. INSULATION: class F. ● PROTECTION: IP 44.
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: stainless steel AISI 304. IMPELLER: stainless steel AISI 304 of the type with centrifugal radial flow.
Other 2CP ● ●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. IMPELLERS: brass, of the type with centrifugal radial flow.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒
electropumps with impeller in technopolymer (2CPm...X - 2CP...X) special mechanical seal other voltages or frequency 60 Hz
RANGE OF PERFORMANCE AT n= 2900 1/min
0 0
10
20
10
30 20
40 30
50
60
40
70
50
80
60
90 70
100 80
90
120
feet
350
100
300
80
200
60
Head H
(metres)
250
150
40
100 2CP160/160 2CP25/140H 2CP25/130N
2CP25/160 2CP25/140M
2CP32/210 2CP32/200
2CP40/180
20 50
0
0
0
50
100
150
200
250
300
350
400
0
3
6
9
12
15
18
21
24
Flow rate Q
l/min
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Single-phase 2CPm 25/130N 2CPm 25/140H 2CPm 160/160
Three-phase 2CP 25/130N 2CP 25/140H 2CP 160/160
POWER
Q
m3/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
l/min
0
20
30
40
50
60
70
80
90
100
110
42
39
37
34
31
28.5
25.5
22
18
15
54
53
51
49
46
42
38
34
29
24
66
64
62
60
57
53
49
44
39.5
35
kW
HP
0.75 1.1 1.5
1 1.5 H metres 2
Q = Flow rate H = Total manometric head
30
Tolerance of the performance curves according to EN ISO 9906 App. A.
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE
POWER
Single-phase
Three-phase
kW
HP
2CPm 25/140M 2CPm 25/160B –––
2CP 25/140M 2CP 25/160B 2CP 25/160A
1.1 1.5 2.2
1.5 2 3
Q = Flow rate H = Total manometric head
m3/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.5
8.4
9.6
10.8
l/min
0
20
30
40
50
60
70
80
90
100
110
125
140
160
180
47
46
45.5
44
43
42
41
38
36
34
31
27
22
56
55
54
53
52
50
48
46
44
41
37
33
26
65
63
62
60
58
56
54
51
47
42
35
Q
H metres 58 68
66.5 65.5
28
Tolerance of the performance curves according to EN ISO 9906 App. A.
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase 2CP 32/200C 2CP 32/200B
POWER kW
HP
3 4
4 5.5
Q = Flow rate H = Total manometric head
m3/h
0
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.5
8.4
9.6
10.8
12.0
15.0
l/min
0
40
50
60
70
80
90
100
110
125
140
160
180
200
250
70
66.5 65.5
65
64
63
62
60.5
59
57
55
52
79
78
77
76
75
74
72
69
66
Q H metres
85
81
80
49.5 46.5 62
58
36 49
Tolerance of the performance curves according to EN ISO 9906 App. A.
P2 (HP)
Absorbed power P 2
(kW)
NPSH
NPSH
(feet)
(metres)
Head H
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase 2CP 32/210B 2CP 32/210A
POWER kW
HP
5.5 7.5
7.5 10
Q = Flow rate H = Total manometric head
m3/h
0
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.5
8.4
9.6
10.8
12.0
15.0
l/min
0
40
50
60
70
80
90
100
110
125
140
160
180
200
250
94
94
93.5
93
92
91
90
89
87
85
83
79
75
70
56
112
111
110
109
108
107
105
102
99
89
74
Q H metres
110.8 110.5 110.3
94
Tolerance of the performance curves according to EN ISO 9906 App. A.
P2 (HP)
Absorbed powerP 2
(kW)
NPSH
NPSH
(feet)
(metres)
HeadH
H (feet)
(metres)
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Flow rate Q
TYPE Three-phase 2CP 40/180C 2CP 40/180B 2CP 40/180A
POWER kW
HP
4 5.5 7.5
5.5 7.5 10
Q = Flow rate H = Total manometric head
Q
m3/h
0
6.0
6.6
7.5
8.4
9.6
10.8
12.0
15.0
18.0
21.0
24.0
l/min
0
100
110
125
140
160
180
200
250
300
350
400
64
62
61
60
59
58
56
54.5
49
43
35
H metres
76
73
72.5
72
71
70
69
67.5
64
59.5
54
46
88
85
84.5
84
83
82
81
79.5
76
72
67
60
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f n
a
h1
DN1
h
h2
DN2
w
TYPE
s
n1
INLETS
DIMENSIONS mm
kg
Single-phase
Three-phase
DN1
DN2
a
f
h
h1
h2
n
n1
w
s
1~
3~
2CPm 25/130N
2CP 25/130N
11/4"
1"
73
330
201
92
109
180
142
1
14.5
14.0
20.1
19.4
24.8
24.1
2CPm 25/140H
2CP 25/140H
1 11/4" 1/4"
1"
74
382
225
93
132
200
162
23
10 10 10
2CPm 160/160
2CP 160/160
11/4"
1"
84
405
263
110
153
225
185
26
11
2CPm 25/140M
2CP 25/140M
11/2"
1"
74
382
225
93
132
200
162
23
10
20.1
19.2
2CPm 25/160B
2CP 25/160B
11/2"
1"
11/2" 1/2"
1"
263 263 263
110 110 110
153 153 153
225 225 225
185 185 185
26 26 26
11 11 11
25.2
2CP 25/160A
401/381 407 401
24.6
–––
86 86 86
-
26.1
–––
2CP 32/200C
11/2"
11/4" 11/4"
132 132 132
172 172 172
266 266 266
206 206 206
19 19 19
39.1
11/2"
304 304 304
-
2CP 32/200B
464 464 464
14
–––
95 95 95
14
-
42.9
–––
2CP 32/210B
2"
11/4"
108
334
139
195
292
232
21
14
-
56.0
–––
2CP 32/210A
2"
11/4"
334
139
195
292
61.7
2" 2"
11/2"
496
334 334
139 139
195 195
292 292
21 21 21
-
2CP 40/180C
232 232 232
14
–––
108 108 108
542 542 542
14
-
49.8
–––
2CP 40/180B
2"
1/2" 111/2"
108
334
139
195
292
232
21
14
-
55.1
–––
2CP 40/180A
2"
11/2"
108
542 542 542
334
139
195
292
232
21
14
-
60.8
1"
11/4"
multi-impeller centrifugal electropumps
Electropumps for domestic use, particularly silent-running, characterisedbyhighyieldsandlow consumption.
RANGEOFPERFORMANCE Flow rate up to 130 l/min (7.8 m3/h) Head up to 50 m
GUARANTEE 2 YEARS according to ourgeneral general terms of sale.of subject to our our general terms of sale. sale. subject to terms GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 40°C Environment temperature up to+ 40°C
● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY, SILENT RUNNING AND ABSENCE OF MAINTENANCE THEY ARE WIDELY USED IN THE DOMESTIC SECTOR AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL OR MEDIUM AUTOCLAVES, FOR IRRIGATING GARDENS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: stainless steel AISI 304. IMPELLERS: of the type with centrifugal radial flow, made of technopolymer (certified for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104 MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. 2-3-4CPm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . 2-3-4CP: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL
EXECUTIONSONREQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
4CP80E
Head H
(metres)
4CP100E
3CP80E 3CP100E
2CP80E
Flow rate Q
TYPE Single-phase 2CPm 80E 3CPm 80E 4CPm 80E 3CPm 100E 4CPm 100E
POWER
Three-phase 2CP 80E 3CP 80E 4CP 80E 3CP 100E 4CP 100E
kW
Q
HP
0.37 0.45 0.60 0.60 0.75
m3/h
0
0.3
0.6
0.9
1.2
l/min
0 27 38 50 36 46
5 26 36 48 35.5 45
10 25 35 47 35 44
15 24 34 45 34 43
20 25 30 40 50 60 22.5 21 20 16.5 13 9 33.5 31 29 25 20 15.5 43 40.5 38.5 33.5 28 22.5 33.5 32.5 32 30 28 26 42 41 40 38 35.5 33
0.50 0.60 0.85 H metres 0.85 1
Q = Flow rate H = Total manometric head
1.5
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
70 5 10 16 23 30
80
90
100 110
5 10 20 17 13.5 26.5 22.5 19
6.6
10 15
7.2
7.8
120 130
5 10
5
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
n
f a
h1
h
DN1
h2
DN2
s
w n1
TYPE Single-phase Three-phase 2CPm 80E 2CP 80E 3CPm 80E 3CP 80E 4CPm 80E 4CP 80E 3CPm 100E 3CP 100E 4CPm 100E 4CP 100E
INLETS DN1
DN2
1" 1" 1" 1" 1" 1"
1" 1" 1" 1" 1" 1"
a 110 110 110 135 110 135
f 334 334 334 367/359 342/334 378
h 172 172 172 172 172 191
DIMENSIONS mm h1 h2 n 134 38 158 134 38 158 158 38 134 38 158 134 38 158 134 61 158
kg n1 116 116 116 116 116 116
w 2 2 2 2 2
s 9 9 9 9 9
1~ 8.6 9.4 10.8 10.2 13.4
3~ 8.6 8.9 10.2 9.4 12.3
verticalmulti-impellerelectropumps
Sturdy vertical multi-impeller electropumps, in stainless steel, characterised by a high yield and particularly silent operation.
RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 105 m
CONSTRUCTIONCHARACTERISTICS ● ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 40°C
● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY AND SILENT RUNNING THEY ARE WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR IN INSTALLATIONS WITH INSUFFICIENT VENTILATION, IN TIGHT SPACES AND SUBJECT TO JETS OF WATER, ETC. THEY CAN WORK WHEN COMPLETELY SUBMERGED.
GUARANTEE 12YEAR subject our general GUARANTEE YEARS accordingto to our general terms terms of sale. of sale.
●
OUTER JACKET AND MOTOR SUPPORT: stainless steel AISI 304 jacket with threaded inlets ISO 228-1. IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLm 2: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW; for the 1.8 kW motor the overload protector is on the outside, on the electric panel, and is of the type with manual reset. VL 2: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: VL m2 VLm
(single-phase) 2 mt power cable type "H07 RN-F" with removable connector. Electric panel with condenser and Schuko plug
VL 2
(three-phase) 2 mt power cable type "H07 RN-F" with removable connector.
EXECUTIONSONREQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
VL2/18
(metres)
VL2/15
VL2/11
Head H
VL2/7 VL2/6 VL2/5
Flow rate Q
TYPE Single-phase VLm 2/5 VLm 2/6 VLm 2/7 VLm 2/11 VLm 2/15 VLm 2/18
POWER
Three-phase ––– ––– VL 2/7 VL 2/11 VL 2/15 VL 2/18
kW
0.45 0.55 0.75 1.1 1.5 1.8
HP
Q
m3/h
0
l/min
0
0.6
0.6 36 0.75 48 1 H metres 60 1.5 75 2 90 105 2.5
1.2
1.8
10
20
30
35 46 58 72 87 102
33 44 55 70 83 98
31 41 51 66 78 92
Q = Flow rate H = Total manometric head
2.4
2.7
3.0
3.3
3.6
3.9
4.2
4.5
4.8
40
45
50
55
60
65
70
75
80
28 26 25 23 22 20 18 16 14 37.5 35 34 31 29 26 23 19.5 16 47 44 42 38 36 32 28 23 18 61 58 55 52 48 44 40 35 30 73 70 66 62 58 53 48 44 38 85 82 78 73 68 63 57 50 45 Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
a DN2
c
h
h2
SINGLE-PHASE CONTROL PANEL
d
h1
DN1
b
s w1
w1
w2 f
n TYPE Single-phase Three-phase VLm 2/5 ––– VLm 2/6 ––– VLm 2/7 VL 2/7 VLm 2/11 VL 2/11 VLm 2/15 VL 2/15 VLm 2/18 VL 2/18
INLETS DN1
11/4"
11/4" 11/4" 11/2"
11/2" 11/2"
N° stages 11/4" 3 11/4" 4 11/4" 5 1 1/4" 5 11/4" 5 11/4" 6 11/4" 7 DN2
a 90 90 90 100 100 100
b 200 200 200 81 200 200 200
w2
c 81 81 81 200 81 81 81
d 66 66 66 66 66 66 66
DIMENSIONS f h 223 432 223 506 223 530 223 223 603 223 633 223 708
mm h1 50 50 50 60 60 60
kg h2 382 456 480 543 573 648
n 183 183 183 183 183 183 183
w1 62 62 62 62 62 62 62
w2 88.5 88.5 88.5 88.5 88.5 88.5 88.5
s 11 11 11 11 11 11 11
1~ 10.9 13.0 16.3 24.1 25.0 30.8
3~ 14.8 22.4 23.4 26.7
verticalmulti-impellerelectropumps
Sturdy vertical multi-impeller electropumps, in stainless steel, characterised by a high yield and particularly silent operation.
RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 105 m
CONSTRUCTIONCHARACTERISTICS ● ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 40°C
● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY AND SILENT RUNNING THEY ARE WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR IN INSTALLATIONS WITH INSUFFICIENT VENTILATION, IN TIGHT SPACES AND AREAS SUBJECT TO JETS OF WATER, ETC. THEY CAN WORK WHEN COMPLETELY SUBMERGED. GUARANTEE 12YEAR subject our general terms GUARANTEE YEARS accordingto to our general terms of sale. of sale.
●
OUTER JACKET AND MOTOR SUPPORT: stainless steel AISI 304 jacket with threaded inlets ISO 228-1. IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLm 4: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW; for the 1.8 kW motor the overload protector is on the outside, on the electric panel, and is of the type with manual reset. VL 4: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: VL m4 VLm
(single-phase ) 2 mt power cable type "H07 RN-F" with removable connector. Electric panel with condenser and Schuko plug.
VL 4
(three-phase ) 2 mt power cable type "H07 RN-F" with removable connector.
EXECUTIONSONREQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
VL4/22
(metres)
VL4/18
VL4/15
Head H
VL4/11 VL4/7 VL4/6 VL4/5
Flow rate Q
TYPE Single-phase VLm 4/5 VLm 4/6 VLm 4/7 VLm 4/11 VLm 4/15 VLm 4/18 –––
POWER
Three-phase ––– ––– VL 4/7 VL 4/11 VL 4/15 VL 4/18 VL 4/22
kW
0.45 0.55 0.75 1.1 1.5 1.8 2.2
HP
Q
m3/h
0
1.2
l/min
0
20
30
40
50
27 37 48 56 72 85 101
26 36 46 54 69 83 98
25 34.5 44 52 66 79 94
24 32.5 41 50 64 76 90
0.6 30 0.75 40 1 50 1.5 H metres 60 2 75 2.5 90 105 3
1.8
2.4
Q = Flow rate H = Total manometric head
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
60
70
22.5 30 38 48 60 73 86
20.5 28 35 46 57 68 80
80
90
100
110
120
18 25 32 43 53 64 75
15.5 21.5 28 39 48 58 67
13 18.5 24 36 43 52 60
10 14.5 19 31 38 44 52
7 10 14 24 32 38 44
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
a DN2
c
h
h2
SINGLE-PHASE CONTROL PANEL
d
h1
DN1
b
s w1
w1
w2 f
n TYPE Single-phase Three-phase VLm 4/5 ––– VLm 4/6 ––– VLm 4/7 VL 4/7 VLm 4/11 VL 4/11 VLm 4/15 VL 4/15 VLm 4/18 VL 4/18 ––– VL 4/22
INLETS DN1
11/4"
11/4" 11/4" 11/2" 11/2" 111/2 " 1/2" 11/2"
N° DN2 stages 11/4" 3 111/4 "" 4 1/4 11/4" 5 4 11/4" 1/4" 11/4" 5 1 1/4" 11/4" 6 11/4" 7
a 90 90 90 100 100 100 100 100
b 200 200 200 81 200 200 200
w2
c 81 81 81 200 81 81 81
d 66 66 66 66 66 66 66
DIMENSIONS f h 223 432 223 506 223 530 223 573 223 603 223 633 223 708
mm h1 50 50 50 60 60 60 60 60
kg h2 382 456 480 513 543 573 648
n 183 183 183 183 183 183 183
w1 62 62 62 62 62 62 62
w2 88.5 88.5 88.5 88.5 88.5 88.5 88.5
s 11 11 11 11 11 11 11
1~ 10.9 13.0 16.3 23.0 24.1 25.0 -
3~ 14.8 21.0 22.4 23.4 26.7
“in-line"multi-impellerelectropumps
Compactmulti-impellerelectropumps,instainless steel, with suction and delivery inlets “in line”, guaranteedagainstallwaterleaks.Theycanwork in a horizontal or vertical position, or when completelysubmerged.
RANGE OF PERFORMANCE Maximum flow rate 80 l/min (4.8 m3/h) Head up to 105 m
CONSTRUCTIONCHARACTERISTICS ● ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 40°C
● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY, SILENT RUNNING AND HIGH YIELD THEY ARE WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR IN INSTALLATIONS WITH INSUFFICIENT VENTILATION, IN TIGHT OR ENCLOSED SPACES, AREAS SUBJECT TO JETS OF WATER AND ON DELICATE SURFACES (E.G. PARQUET, CARPET, ETC.) AS ANY LEAKS OF WATER FROM THE MECHANICAL SEAL DO NOT COME OUT OF THE PUMP ITSELF.
GUARANTEE subject toto our general GUARANTEE12YEAR YEARS according our general termsterms of sale. of sale.
●
OUTER JACKET AND MOTOR SUPPORT: stainless steel AISI 304 jacket with threaded inlets ISO 228-1. IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLEm 2: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW; for the 1.8 kW motor the overload protector is on the outside, on the electric panel, and is of the type with manual reset. VLE 2: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: VLE m2 VLEm
(single-phase) 2 mt power cable type "H07 RN-F" with removable connector. Electric panel with condenser and Schuko plug.
VLE 2
(three-phase) 2 mt power cable type "H07 RN-F" with removable connector.
EXECUTIONSONREQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
VLE2/18
(metres)
VLE2/15
VLE2/11
Head H
VLE2/7
VLE2/6
VLE2/5
Flow rate Q
TYPE Single-phase VLEm 2/5 VLEm 2/6 VLEm 2/7 VLEm 2/11 VLEm 2/15 VLEm 2/18
POWER
Three-phase ––– ––– VLE 2/7 VLE 2/11 VLE 2/15 VLE 2/18
kW
Q
HP
0.45 0.55 0.75 1.1 1.5 1.8
m3/h
0
l/min
0
0.6 36 0.75 48 1 H metres 60 1.5 75 2 90 105 2.5
0.6
1.2
1.8
10
20
30
35 46 58 72 87 102
33 44 55 70 83 98
31 41 51 66 78 92
Q = Flow rate H = Total manometric head
2.4
2.7
3.0
3.3
3.6
3.9
4.2
4.5
4.8
40
45
50
55
60
65
70
75
80
28 26 25 23 22 20 18 16 14 37.5 35 34 31 29 26 23 19.5 16 47 44 42 38 36 32 28 23 18 61 58 55 52 48 44 40 35 30 73 70 66 62 58 53 48 44 38 85 82 78 73 68 63 57 50 45 Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Horizontalinstallation
Vertical installation DN2
h
SINGLE-PHASE CONTROL PANEL
Ø
c
DN1
a
DN2
b
h
DN1
Ø TYPE Single-phase Three-phase VLEm 2/5 ––– VLEm 2/6 ––– VLEm 2/7 VLE 2/7 VLEm 2/11 VLE 2/11 VLEm 2/15 VLE 2/15 VLEm 2/18 VLE 2/18
INLETS DN
11/4" 11/4"
11/4 1/4" 1 " 11/4" 11/4" 11/4"
N° stages 3 4 5 5 5 6 7
Ø 397 135 495 547 153 652
DIMENSIONS mm h a 397 471 495 81 547 577 652
kg b
c
200
66
1~ 8.4 10.5 13.8 20.6 21.5 27.3
3~ 12.3 18.9 19.9 23.2
“in-line"multi-impellerelectropumps
Compactmulti-impellerelectropumps,instainless steel, with suction and delivery inlets “in line”, guaranteedagainstallwaterleaks.Theycanwork in a horizontal or vertical position, or when completelysubmerged.
RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 105 m
CONSTRUCTIONCHARACTERISTICS ● ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 40°C
● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS
OUTER JACKET AND MOTOR SUPPORT: stainless steel AISI 304 jacket with threaded inlets ISO 228-1. IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). SCREWS: stainless steel AISI 304. MOTOR: electric, asynchronous for continuous duty. VLm 4: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW; for the 1.8 kW motor the overload protector is on the outside, on the electric panel, and is of the type with manual reset. VL 4: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY, SILENT RUNNING AND HIGH YIELD THEY ARE WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR IN INSTALLATIONS WITH INSUFFICIENT VENTILATION, IN TIGHT OR ENCLOSED SPACES, AREAS SUBJECT TO JETS OF WATER AND ON DELICATE SURFACES (E.G. PARQUET, CARPET, ETC.) AS ANY LEAKS OF WATER FROM THE MECHANICAL SEAL DO NOT COME OUT OF THE PUMP ITSELF.
VL m4 VLm
(single-phase) 2 mt power cable type "H07 RN-F" with removable connector. Electric panel with condenser and Schuko plug.
VL 4
(three-phase) 2 mt power cable type "H07 RN-F" with removable connector.
GUARANTEE 12YEAR subject our general terms GUARANTEE YEARS accordingto to our general terms of sale. of sale.
EXECUTIONSONREQUEST
●
THE ELECTROPUMPS ARE COMPLETE WITH:
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
(metres)
VLE4/18
Head H
VLE4/22
VLE4/11
VLE4/15
VLE4/7 VLE4/6 VLE4/5
Flow rate Q
TYPE Single-phase VLEm 4/5 VLEm 4/6 VLEm 4/7 VLEm 4/11 VLEm 4/15 VLEm 4/18 –––
POWER
Three-phase ––– ––– VLE 4/7 VLE 4/11 VLE 4/15 VLE 4/18 VLE 4/22
kW
Q
HP
0.45 0.55 0.75 1.1 1.5 1.8 2.2
m3/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
l/min
0
20
30
40
50
60
70
80
90
100
110
120
27 37 48 56 72 85 101
26 36 46 54 69 83 98
25 34.5 44 52 66 79 94
24 32.5 41 50 64 76 90
22.5 30 38 48 60 73 86
20.5 28 35 46 57 68 80
18 25 32 43 53 64 75
15.5 21.5 28 39 48 58 67
13 18.5 24 36 43 52 60
10 14.5 19 31 38 44 52
7 10 14 24 32 38 44
0.6 30 0.75 40 1 50 1.5 H metres 60 2 75 2.5 90 3 105
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Horizontal installation
Vertical installation DN2
h
SINGLE-PHASE CONTROL PANEL
Ø
c
DN1
a
DN2
b
h
DN1
Ø TYPE Single-phase Three-phase VLEm 4/5 ––– VLEm 4/6 ––– VLEm 4/7 VLE 4/7 VLEm 4/11 VLE 4/11 VLEm 4/15 VLE 4/15 VLEm 4/18 VLE 4/18 ––– VLE 4/22
INLETS DN
11/4" 11/4" 11/4"
11/4" 11/4" 11/4" 11/4"
N° stages 3 4 5 4 5 6 7
Ø 397 135 495 517 547 153 577 652
DIMENSIONS mm h a 397 471 495 517 81 547 577 652
kg b
c
200
66
1~ 8.4 10.5 13.8 19.5 20.6 21.5 -
3~ 12.3 17.5 18.9 19.9 23.2
stainless steel centrifugal electropumps
RANGEOFPERFORMANCE Maximum flow rate 160 l/min (9.6 m3/h) Maximum head 23 m
GUARANTEE YEARS according our general terms of sale. subject totoour general terms of sale. GUARANTEE 12YEAR CONSTRUCTIONCHARACTERISTICS PUMP BODY: stainless steel AISI 304, with threaded inlets ISO 228/1. ● COVER OF THE PUMP BODY AND DIFFUSOR: AISI 304. ● IMPELLER: stainless steel AISI 304, of the type with centrifugal radial flow. ● MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. ● MECHANICAL SEAL: ceramic - graphite - NBR. ● ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. AL-RED 135m: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. AL-RED 135: three-phase 230/400 V - 50 Hz. ● INSULATION : class F. ● PROTECTION: IP 44. ● REGISTERED MODEL nº 72753. ● AL-RED® is a REGISTERED TRADE MARK ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 55°C EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3 USESANDINSTALLATIONS It is recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THE CONSTRUCTIVE CHARACTERISTICS OF THESE CENTRIFUGAL ELECTROPUMPS WE ADVISE THEIR USE IN THE DOMESTIC, AGRICULTURAL AND INDUSTRIAL SECTORL ALL THE COMPONENTS IN CONTACT WITH THE PUMPED LIQUID ARE IN STAINLESS STEEL AISI 340 TO GUARANTEE TOTAL HYGIENE AND MAXIMUM RESISTANCE TO CORROSION. The pump must be installed in enclosed places, or at least protected against inclement weather.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
execution in stainless steel EN 10088-3 - 1.4401 (AISI 316) special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
30
5
0
10
15
5
20
10
25
15
30
20
35
25
40 30
45 35
40 feet 90
25
80
70
Head H
(metres)
AL-RED135
20
51
60
54
η=56%
15
50
40 53
10 30
20
5 10
0
25
0 0
1
50 2
75
3
TYPE
4
POWER
Single-phase Three-phase AL-RED 135m AL-RED 135
100
Q
m3/h
kW
HP
l/min
0.75
1
H metres
5
125
6
Flow rate Q
0
1.2
0 23
7
8
2.4
3.6
20
40
21
20.5
Q = Flow rate H = Total manometric head
150
l/min
175
9
10
m3 /h
11
4.8
6.0
7.2
8.4
9.6
60
80
100
120
140
160
20
18.5
17
15
13
10
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
n
a
h3 h1
h
DN1
h2
DN2
s w
TYPE Single-phase
Three-phase
AL-RED 135m AL-RED 135
n1
INLETS
DIMENSIONS mm
kg
DN1
DN2
a
f
h
h1
h2
h3
n
n1
w
s
1~
3~
11/4"
1"
31.5
295
206
97
103
200
182
115
93
10
9.1
9.1
0
stainless steel electropumps
Centrifugal pumps made of stainless steel AISI 316, equipped with an open impeller, ideal for transferring liquids containing impurities.
RANGEOFPERFORMANCE Flow rate up to 350 l/min (21 m3/h) Head up to 20 m
accordingto to our general termsterms of sale. of sale. GUARANTEE YEARS GUARANTEE 12YEAR subject our general
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 90°C Environment temperature up to + 40°C Passage of solid bodies Ø 10 mm
● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3 USESANDINSTALLATIONS They are recommended for pumping water and liquids that are chemically non aggressive for the materials of which the pump is made. THE CONSTRUCTIVE SOLUTION OF THE OPEN IMPELLER ALLOWS PUMPING OF LIQUIDS RELATIVELY LOADED WITH IMPURITIES WITHOUT RISK OF CLOGGING THE IMPELLER. FOR THIS CHARACTERISTIC THE PUMPS IN THE PRO-NGA SERIES ARE SPECIFICALLY USED IN SYSTEMS FOR WASHING FRUIT, VEGETABLES, FISH, SHELLFISH, MEAT, IN INDUSTRIAL SYSTEMS FOR WASHING METAL PARTS, GLASS CONTAINERS, AND FOR THE CIRCULATION OF COOLING LIQUIDS. The pumps must be installed in enclosed places, or at least protected against inclement weather.
●
PUMP BODY : stainless steel AISI 316, with threaded inlets ISO 228/ 1. PUMP BODY COVER: stainless steel AISI 316. OPEN IMPELLER: stainless steel AISI 316. MOTOR SHAFT: stainless steel AISI 316. MECHANICAL SEAL: ceramic - graphite - viton - AISI 316 ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PRO-NGAm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. PRO-NGA: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz protection IP 55
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PRO-NGA1A
Head H
(metres)
PRO-NGA1B
Flow rate Q
TYPE
POWER
Single-phase Three-phase PRO-NGAm 1B PRO-NGA 1B PRO-NGAm 1A PRO-NGA 1A
kW
0.55 0.75
Q
HP
m3/h
0
3
6
9
12
15
18
19.5
21
l/min
0 18 20
50 17 19.5
100 16 18
150 14.5 16.5
200 13 15
250 10.5 12.5
300 8 10
325 6 8
350
0.75 H metres 1.00
Q = Flow rate H = Total manometric head
6
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
n
a
h1
DN1
h
h2
DN2
s w
TYPE Single-phase Three-phase PRO-NGAm 1B PRO-NGA 1B PRO-NGAm 1A PRO-NGA 1A
n1
INLETS DN1
DN2
11/2" 11/2" 11/2"
11/2" 11/2" 11/2"
a 41 41 41
f 297 297 297
h 227 227 227
DIMENSIONS mm h1 h2 n 92 135 190 135 190 92 92 135 190
kg n1 160 160 160
w 50 50 50
s 10 10 10
1~ 13.0 13.1
3~ 12.0 12.1
multi-impeller centrifugal electropumps stainless steel pump body
Electropumps for domestic use, particularly silent-running, characterisedbyhighyieldsandlow consumption
RANGEOFPERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 50 m
GUARANTEE 2 YEARS according to ourgeneral general terms of sale. subject to our terms of sale. GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 7 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3 ●
PUMP BODY: stainless steel AISI 304, with threaded inlets ISO 228/ 1. PUMP BODY COVER: stainless steel AISI 304. IMPELLERS: of the type with centrifugal radial flow, made of technopolymer (certified for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. 3-4CRm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . 3-4CR: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR RELIABILITY AND SILENT RUNNING THEY ARE WIDELY USED IN THE DOMESTIC SECTOR AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL OR MEDIUM AUTOCLAVES, FOR IRRIGATING GARDENS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
EXECUTIONSONREQUEST
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
3CR80 3CR100
Head H
(metres)
4CR80
Flow rate Q
TYPE Single-phase 3CRm 80 4CRm 80 3CRm 100
POWER
Three-phase 3CR 80 4CR 80 3CR 100
kW
0.45 0.60 0.60
HP
Q
m3/h
0
0.3
0.6
0.9
1.2
l/min
0 38 50 36
5 36 48 35.5
10 35 47 35
15 34 45 34
20 25 30 32.5 31 29 43 40.5 38.5 33.5 32.5 32
0.60 0.85 H metres 0.85
Q = Flow rate H = Total manometric head
1.5
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
40 25 33.5 30
50 20 28 28
60 15.5 22.5 25.5
70 10 16 23
80 5 10 20
90
100
110
120
17
13.5
10
5
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
n
a
h1
h
DN1
h2
DN2
s
w
TYPE Single-phase 3CRm 80 4CRm 80 3CRm 100
n1
INLETS Three-phase 3CR 80 4CR 80 3CR 100
DN1
DN2
1" 1" 1" 1"
1" 1" 1" 1"
a 90 90 90 90
f 345 353/345 353/345 353/345
h 174 174 174
DIMENSIONS mm h1 h2 n 122 52 160 52 160 122 52 160 122 52 160
kg n1 120 120 120
w 95 95 95
s 9 9 9
1~ 6.9 7.6 7.5
3~ 6.3 6.9 6.9
"JET" self-priming electropumps stainless steel pump body
RANGEOFPERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 72 m
GUARANTEE 2 YEARS according to ourgeneral general terms of sale. subject to our terms of sale. GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3 ●
PUMP BODY: stainless steel AISI 304, with threaded inlets ISO 228/ 1. PUMP BODY COVER: stainless steel AISI 304. EJECTOR Group: technopolymer (certified for drinking water). IMPELLER: technopolymer (certified for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104 MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. JCRm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . JCR: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. JCR SELF-PRIMING PUMPS ARE DESIGNED FOR SUCKING UP WATER EVEN IN THE PRESENCE OF AIR MIXED WITH THE PUMPED LIQUID . FOR THEIR RELIABILITY AND ABSENCE OF MAINTENANCE THEY ARE RECOMMENDED FOR DOMESTIC USE, ESPECIALLY FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL OR MEDIUM AUTOCLAVES, FOR IRRIGATING GARDENS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
EXECUTIONSONREQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
JCR15H
Head H
(metres)
JCR12H
JCR10H JCR15M JCR1A
JCR12M JCR10M
JCR1B JCR1C
Flow rate Q
TYPE Single-phase JCRm 1C JCRm 1B JCRm 1A JCRm 10H JCRm 12H JCRm 15H JCRm 10M JCRm 12M JCRm 15M
POWER
Three-phase JCR 1C JCR 1B JCR 1A JCR 10H JCR 12H JCR 15H JCR 10M JCR 12M JCR 15M
kW
0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1
HP
m3/h
Q
l/min
0.50 0.70 0.85 1 1.25 H metres 1.5 1 1.25 1.5
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
0
5
10
15
20
25
30
35
40
50
60
70
80
35 41 47 56 64 72 46 50 55
32 36 42 50 58 67 44 48 53
27 31 38 45 53 61 41 45 50
24 27 34 41 48 56 39 43 48
21 24 31 37 44 51 37 41 46
19 22 28.5 33 40 47 35 39 43
17 20 26 30 36 43 32 37 41
16 19 24 27 33 40 30 36 39
15 17 22 25 31 37 28 34 37
13 15 19 22 26 32 25 30 34
22 27 31
21 25 29
19 23 27
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS n
f a
h1
h
DN1
h2
DN2
w
TYPE Single-phase JCRm 1C JCRm 1B JCRm 1A JCRm 10H-M JCRm 12H-M JCRm 15H-M
INLETS Three-phase JCR 1C JCR 1B JCR 1A JCR 10H-M JCR 12H-M JCR 15H-M
DN1
DN2
1" 1" 1" 1" 11/4" 1/4"" 111/4 11/4"
1" 1" 1" 1" 1" 1" 1" 1"
a 90 90 90 90 117 117 117 117
s
n1
f 345 345 345 353/345 406 406 406
h 174 174 174 174 206 206 206
DIMENSIONS mm h1 h2 n 122 52 160 122 52 160 122 52 160 145 55 184 145 55 184 184 145 55 184
kg n1 120 120 120 135 135 135
w 95 95 95 110 110 110 110
s 9 9 9 10 10 10
1~ 5.6 5.7 6.9 9.4 10.5 10.8
3~ 5.8 6.0 6.5 9.6 9.6 10.4
self-priming electropumps with peripheral impeller
RANGEOFPERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 70 m
GUARANTEE YEARS according ourgeneral general terms of sale. subject to to our terms of sale. GUARANTEE 12 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 60°C Environment temperature up to + 40°C EXECUTIONANDSAFETYSTANDARDS EN 60034-1 IEC 34-1 CEI 2-3
● ●
LANTERN (patent nº 1289150): aluminium with front shim disk in brass; reduces starting difficulties due to blockage of the impeller after long periods of inactivity.
●
IMPELLER: brass, of the type with radial peripheral vanes.
●
MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104.
●
MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PKSm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. PKS: three-phase 230/400 V- 50 Hz INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753.
●●
USESANDINSTALLATIONS They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR COMPACTNESS, RELIABILITY AND ECONOMY THEY ARE SUITABLE FOR DOMESTIC USE AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL AUTOCLAVES, FOR IRRIGATING GARDENS, DRAWING WATER FROM TANKS OR WELLS DOWN TO A DEPTH OF 9 METRES AND IN ALL CASES WHERE THERE IS THE PRESENCE OF AIR OR GAS IN THE LIQUID TO BE PUMPED; the pump is provided with a check flap valve on the intake so that it is no longer necessary to fit a foot valve. The pumps must be installed in enclosed places, or at least protected against inclement weather.
PUMP BODY: cast iron, with threaded inlets ISO 228/1. CHECK FLAP VALVE: incorporated in the suction inlet.
● ●
EXECUTIONSONREQUEST
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PKS80 PKS70
(metres)
PKS65
Head H
PKS60
Flow rate Q
TYPE Single-phase PKSm 60 PKSm 65 PKSm 70 PKSm 80
POWER
Three-phase PKS 60 PKS 65 PKS 70 PKS 80
Q
kW
HP
0.37 0.50 0.60 0.75
0.50 0.70 0.85 1
m3/h
0
l/min
H metres
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
0
5
10
15
20
25
30
35
40
45
50
40 55 65 70
38 50 62 66
33.5 45.5 57 61
29 40.5 52 56
24 36 47 51
19.5 31 42 46
15 27 37 41
10 22 32 36.5
5 17 27 31
12.5 22 27
8 18 22
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
n f
k
DN2
h1
h
h3
h2
DN1
i
a
TYPE Single-phase Three-phase PKSm 60 PKS 60 PKSm 65 PKS 65 PKSm 70 PKS 70 PKSm 80 PKS 80
s
w
n1
m
INLETS DN1
DN2
1" 1" 1" 1" 1"
1" 1" 1" 1" 1"
a f h 29 230 192 192 29 238/230 192 29 29 260 200 200 29 260 200
h1 156 156 156 164 164 164
h2 34 34 34 34 34
DIMENSIONS h3 i 190 110 190 190 110 110 198 110 198 198 110
mm m 80 80 80 90 90 90
kg n 150 150 150 160 160 160
k 120 120 120 138 138 138
n1 100 100 100 112 112 112
w 55 55 55 62 62 62
s 7 7 7 7 7
1~ 6.1 7.7 10.7 10.8
3~ 6.1 7.1 9.6 9.7
"JET" self-priming electropumps
RANGEOFPERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 47 m
GUARANTEE 2 YEARS according our general general terms of sale.of sale. subject to to our terms GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3 ● ●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: stainless steel AISI 304. EJECTOR GROUP: technopolymer (certified for drinking water). IMPELLERS: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite -NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. JSWm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . JSW: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753.
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCKING UP WATER EVEN IN THE PRESENCE OF AIR MIXED WITH THE PUMPED LIQUID. FOR THEIR RELIABILITY AND ABSENCE OF MAINTENANCE THEY ARE RECOMMENDED FOR DOMESTIC USE, ESPECIALLY FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL OR MEDIUM AUTOCLAVES, FOR IRRIGATING GARDENS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
EXECUTIONSONREQUEST
⇒ ⇒
electropumps with impeller in technopolymer (JSWm1...X - JSW1...X) other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
HS
JSW1A
JSW1B
Head H
(metres)
JSW1C
Flow rate Q
TYPE Single-phase JSWm 1C JSWm 1B JSWm 1A
POWER
Three-phase JSW 1C JSW 1B JSW 1A
kW
0.37 0.50 0.60
HP
Q
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0 35 41 47
5 32 36 42
10 27 31 38
15 24 27 34
20 21 24 31
25 19 22 28.5
30 17 20 26
35 16 19 24
40 15 17 22
45 14 16 21.5
50 13 15 19
0.50 0.70 H metres 0.85
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f n
a
h1
h3
h
DN1
h2
DN2
s
w
TYPE Single-phase Three-phase JSWm 1C JSW 1C JSWm 1B JSW 1B JSWm 1A JSW 1A
n1
INLETS DN1
DN2
1" 1" 1" 1"
1" 1" 1" 1"
a 115 115 115 115
f 379 379 379 387/379
h 171 171 171 171
h1 127 127 127
DIMENSIONS mm h2 h3 33.5 160.5 160.5 33.5 33.5 160.5
kg n 160 160 160
n1 124 124 124
w 24 24 24
s 10 10 10
1~ 9.3 10.0 10.2
3~ 9.1 9.5 10.1
"JET" self-priming electropumps
RANGEOFPERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 70 m
according our general terms of sale. of sale. GUARANTEE 2 YEARS subject totoour general terms GUARANTEE 1 YEAR
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCKING UP WATER EVEN IN THE PRESENCE OF AIR MIXED WITH THE PUMPED LIQUID. FOR THEIR RELIABILITY AND ABSENCE OF MAINTENANCE THEY ARE RECOMMENDED FOR DOMESTIC USE, ESPECIALLY FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL OR MEDIUM AUTOCLAVES, FOR IRRIGATING GARDENS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: stainless steel AISI 304. EJECTOR GROUP: technopolymer (certified for drinking water). IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite -NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. JSWm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . JSW: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753.
EXECUTIONSONREQUEST
⇒ ⇒
electropumps with impeller in technopolymer (JSWm...X - JSW...X) other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
JSW15H
JSW10H JSW15M JSW12M
JSW10M
Head H
(metres)
JSW12H
Flow rate
TYPE Single-phase JSWm 10H JSWm 12H JSWm 15H JSWm 10M JSWm 12M JSWm 15M
POWER
Three-phase JSW 10H JSW 12H JSW 15H JSW 10M JSW 12M JSW 15M
kW
0.75 0.90 1.1 0.75 0.90 1.1
HP
Q
Q
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.4
2.7
3.0
3.6
4.2
4.8
l/min
0 56 64 70 46 50 55
5 51 58 66 42 48 52
10 47 54 62 40 46 50
15 44 51 58 38 44 48
20 41 48 54 37 42 46
25 39 45 51 35 41 45
30 36 43 48 33 39 43
40 32 38 43 30 36 40
45 30 36 41 29 35 39
50 28 34 38 27 33 37
60
70
80
25 31 35
23 29 33
21 27 30
1 1.25 1.5 H metres 1 1.25 1.5
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
n
f a
h1
h
h3
DN1
h2
DN2
TYPE Single-phase Three-phase JSWm 10H JSW 10H JSWm 12H JSW 12H JSWm 15H JSW 15H JSWm 10M JSW 10M JSWm 12M JSW 12M JSWm 15M JSW 15M
INLETS DN1
DN2
1" 1" 1" 1" 1" 1" 1"
1" 1" 1" 1" 1" 1" 1"
s
n1
w
a 113.5 113.5 113.5 113.5 113.5 113.5 113.5
f 402 402 402 402 402 402 402
h 201 201 201 201 201 201 201
h1 147 147 147 147 147 147 147
DIMENSIONS mm h2 h3 35 182 35 182 35 182 35 182 35 182 35 182 35 182
kg n 180 180 180 180 180 180 180
n1 142 142 142 142 142 142 142
w 22 22 22 22 22 22 22
s 10 10 10 10 10 10 10
1~ 13.7 15.0 15.2 13.7 15.0 15.2
3~ 13.8 14.0 14.2 13.8 14.0 14.2
"JET" self-priming electropumps
RANGEOFPERFORMANCE Flow rate up to 160 l/min (9.6 m3/h) Head up to 96 m
GUARANTEE 2 YEARS according to our general terms terms of sale. subject to our general of sale. GUARANTEE 1 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
USESANDINSTALLATIONS They are recommended for pumping clean water and liquids that are chemically non aggressive for the materials of which the pump is made. JSW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCKING UP WATER EVEN IN THE PRESENCE OF AIR MIXED WITH THE PUMPED LIQUID. FOR THEIR RELIABILITY AND ABSENCE OF MAINTENANCE THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL AND INDUSTRIAL USE, ESPECIALLY FOR DISTRIBUTING WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATING GARDENS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
PUMP BODY: cast iron, with threaded inlets ISO 228/1. PUMP BODY COVER: cast iron. EJECTOR GROUP: technopolymer (certified for drinking water). IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. JSWm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . JSW: three-phase230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL nº 72753.
EXECUTIONSONREQUEST
⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
JSW3BH
JSW3AM
JSW3CH
JSW3BM
JSW3AL
JSW3CM
JSW3BL
Head H
(metres)
JSW3AH
JSW3CL
Flow rate Q
TYPE Single-phase JSWm 3CH JSWm 3BH ––– JSWm 3CM JSWm 3BM ––– JSWm 3CL JSWm 3BL –––
POWER
Three-phase JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL
Q
m3/h
0
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
3.6
4.2
4.8
6.0
l/min
0
10
15
20
25
30
35
40
45
50
60
70
80
100 120
64 76 96 52 60 74 42 51 62
60 70 90 50 58 70 40 48 60
55 67 86 48 56 68 39 46 58
51 64 82 45 54 67 38 45 57
48 61 79 44 52 65 37 44 56
45 58 75 42 51 63 36 43 55
42.5 55.5 71.5 40 49 61 35 42 54
40 53 69 38 47 59 34 41 53
39 51 66 37 46 58 33 40 52
37 49 64 35 45 56 32 39 51
34 45 58 32 42 54 30 37 49
31 41 54 29 39 51 28 35 47
39 50 27 37 49 26 33 45
kW
HP
1.1 1.5 2.2 1.1 1.5 2.2 1.1 1.5 2.2
1.5 2 3 1.5 2 H metres 3 1.5 2 3
Q = Flow rate H = Total manometric head
23 33 44 23 30 42
7.2
20 30 40 20 27 39
8.4
9.6
140 160
17 24 36.5
15 22 35
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS f
n
a
h1
h3
h
h2
DN1
DN2
w
TYPE Monofase JSWm 3CH JSWm 3BH ––– JSWm 3CM JSWm 3BM ––– JSWm 3CL JSWm 3BL –––
INLETS Trifase JSW 3CH JSW 3BH JSW 3AH JSW 3CM JSW 3BM JSW 3AM JSW 3CL JSW 3BL JSW 3AL
DN1
DN2
11/4" 11/4" 11/4" 11/4" 1/4"" 111/4 11/4" 11/4" 11/4" 11/4"
1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
s
n1
a 155 155 155 155 155 155 155 155 155
f 497 517/497 517 497 523 517/497 517 497 517/497 517
h 233 233 233 233 242 233 233 233 233 233
h1 165 165 165 165 165 165 165 165 165 165
DIMENSIONS mm h2 h3 43 208 43 208 43 208 43 208 43 208 43 208 43 208 43 208 43 208
kg n 206 206 206 206 206 206 206 206 206
n1 164 164 164 164 164 164 164 164 164
w 30 30 30 30 30 30 30 30 30
s 11 11 11 11 11 11 11 11 11 11
1~ 25.4 26.5 25.4 26.5 25.4 26.5 -
3~ 23.5 25.7 26.8 23.5 25.7 26.8 23.5 25.7 26.8
"JET" self-priming electropumps for deep boreholes
RANGEOFPERFORMANCE Flow rate up to 3600 l/h
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Manometric suction height up to 45 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS JDW SELF-PRIMING PUMPS ARE DESIGNED FOR SUCKING UP CLEAN WATER EVEN IN THE PRESENCE OF AIR MIXED WITH THE PUMPED LIQUID AND IN CASES WHERE THE WATER LEVEL IS AT A DEPTH OF MORE THAN 9 METRES. THEY ARE RECOMMENDED FOR DOMESTIC USE, FOR DISTRIBUTING WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATING GARDENS. The pumps must be installed in enclosed places, or at least protected against inclement weather.
GUARANTEE 12YEAR subject totoour general terms of sale. GUARANTEE YEARS according our general terms of sale.
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. EJECTOR BODY: cast iron NOZZLE, VENTURI AND DIFFUSER: technopolymer. IMPELLER: brass. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. JDWm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . JDW: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONS ON REQUEST
⇒ ⇒
electropumps with impeller in technopolymer (JDWm...X - JDW...X) other voltages or frequency 60 Hz
DESCRIPTION Series Single-phase motor Motor size Type of nozzle and venturi Min. well diameter in inches
JDW m 1C / 30 - 4”
JDW self-priming electropumps for 4" wells (withimmersedejector)
PERFORMANCE DATA AT n= 2900 1/min
TYPE Single-phase JDWm 1C/30 -4” JDWm 1B/30-4” JDWm 1A/30 -4” JDWm 2/30 -4” JDWm 1C/20-4” JDWm 1B/20-4” JDWm 1A/20 -4” JDWm 2/20 -4” JDWm 1C/10-4” JDWm 1B/10-4” JDWm 1A/10 -4” JDWm 2/10 -4” JDWm 1C/30-4” JDWm 1B/30-4” JDWm 1A/30 -4” JDWm 2/30 -4” JDWm 2/20 -4” JDWm 1C/30-4” JDWm -1B/30-4” JDWm 1A/30 -4” JDWm 2/30 -4” JDWm 1A/30 -4” JDWm 2/30 -4” JDWm 2/30 -4” JDWm 2/30 -4”
HS
POWER
Three-phase
kW
HP
JDW 1C/30-4” JDW 1B/30-4” JDW 1A/30-4” JDW 2/30 -4” JDW 1C/20-4” JDW 1B/20-4” JDW 1A/20-4” JDW 2/20 -4” JDW 1C/10-4” JDW 1B/10-4” JDW 1A/10-4” JDW 2/10 -4” JDW 1C/30-4” JDW 1B/30-4” JDW 1A/30-4” JDW 2/30 -4” JDW 2/20 -4” JDW 1C/30-4” JDW 1B/30-4” JDW 1A/30-4” JDW 2/30 -4” JDW 1A/30-4” JDW 2/30 -4” JDW 2/30 -4” JDW 2/30 -4”
0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 1.1 0.50 0.60 0.75 1.1 0.75 1.1 1.1 1.1
0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 1.5 0.70 0.85 1 1.5 1 1.5 1.5 1.5
FLOW RATE LITRES/HOUR 0
120 240 360 480 600 720 840 960 1080 1200 1440 1560 1680 1800 1920 2040 2160 2400 2700 3000 3300 600
41 45 53 81 28 31 40 67 21 24 30 51 36 38 46 74 58 23 25 32 61 25 54 47 40
37 41 50 75 24 28 36 65 20 23 29 50 32 34 42 68.5 56 19 21 27 56 18.5 49 42.5 35
TOTAL MANOMETRIC HEAD IN METRES
metres
15
20
30
35 40 45
32 37 46 70 22 26 34 62 18 22 28 49 27 31 38 63 53 15 17 22 51 14 45 38 30
29 25 23 20 18 16 14 12 33 30 27 24 22 20 18 16 12 42 39 37 34 31 29 27 24 20 65 61 57 53 50 47 44 41 35 32.5 30 21 19 18 16 14 13 12 11 10 9 25 23 21.5 20 18.5 17 16 15 13 12.511.5 32 30 28 27 26 24.5 23 22 19 18 17 16 60 58 56 54 52.5 51 49 47 44 42.5 41 39.5 17 16 15.5 15 14 13 12 11.5 11 10 9.5 9 21 20 19.5 19 18 17 16 15.5 14 13.5 13 12 27 26 25.5 25 24 23 22 21 20 19.518.517.5 48 47 46 45 44.5 44 43 42 41 40 39 38 24 20 17 14 12 28 25 21.5 19 17 14 12 34 31 28 25 22 20 18 16 59 54 50 46 43 40 37.5 35 32.5 30 51 49 47 45.5 44 42 40 39 36 35 33 32 12 14 18 15.5 46.5 42 38 35 32.5 30
15 14 38 36 35 32
29
11 17 16 15 37 36.5 36 34.5 33 30.5 29 27
31 30
40 36 33 30 34 30
HS = Suction height
Tolerance of the performance curves according to EN ISO 9906 App.
DIMENSIONSANDWEIGHTS
A.
f a
DN3
TUBO DI ASPIRAZIONE
ALIMENTAZIONE UGELLO
HS= ALTEZZA DI ASPIRAZIONE
h2
DN1
a1
DN2
w
SUCTION INLET NOZZLE FEED INLET
EJECTOR
a2
De
TYPE DN4
FOOT VALVE
DNp
Single-phase Three-phase D N p D N 1 D N 2 D N 3 D N 4 D e JDWm 1C JDWm 1B JDWm 1A JDWm 2
JDW 1C JDW 1B JDW 1A JDW 2
4" 4" 4" 4" 4"
11/4" 11/4" 11/4" 11/4" 11/4"
1" 1" 1" 1" 1"
1" 1" 1" 1" 1"
1" 1" 1" 1" 1"
96 96 96 96 96
DIMENSIONS mm h h1 h2 n
a
a1
a2
f
69.5 69.5 69.5 75
46 46 46 46 46
148 148 148 148 148
350 350 350 434
181 92 201 92 201 92 242 108
181 181 181 207
180 180 180 206
n1 144 144 144 164
w
s
kg* 1~ 3~
24 10 15.0 15.0 24 10 15.3 15.3 10 24 10 16.4 15.4 22 10 24.6 22.7 (*weight with ejector)
JDW self-priming electropumps for 3" wells (with immersed ejector)
PERFORMANCE DATA AT n= 2900 1/min
TYPE
FLOW RATE LITRES/HOUR 360 480 600
HS
POWER
0
Single-phase
Three-phase
kW
HP
JDWm 1C -3”
JDW 1C -3”
0.50
0.70
JDWm 1B -3”
JDW 1B -3”
0.60
0.85
JDWm 1A -3”
JDW 1A -3”
0.75
1
JDWm 2 -3”
JDW 2 -3”
1.1
JDWm 1C -3”
JDW 1C -3”
JDWm 1B -3” JDWm 1A -3”
120
240
720
840
960
TOTAL MANOMETRIC HEAD IN METRES
metres 32
28
24
22
19
18
15
36
32
29
26
24
22
19
17
39
35
32
29
27
25
22
20
17
1.5
61
56
51
46
42
38
35
33
30
0.50
0.70
26
23
19
17
JDW 1B -3”
0.60
0.85
JDW 1A -3”
0.75
1
JDWm 2 -3”
JDW 2 -3”
1.1
JDWm 1C -3”
JDW 1C -3”
JDWm 1B -3”
JDW 1B -3”
JDWm 1A -3”
15
30
27
24
21
18
33
30
27
23
21
17
1.5
55
50
46
41
37
33
0.50
0.70
19
15
0.60
0.85
23
19
JDW 1A -3”
0.75
1
27
24
JDWm 2 -3”
JDW 2 -3”
1.1
1.5
36
33
JDWm 2 -3”
JDW 2 -3”
1.1
1.5
20
25
30
30
22
47
43
39
39
34
30 Tolerance of the performance curves according to EN ISO 9906 App.
HS = Suction height
A.
DIMENSIONSANDWEIGHTS
f a
EXECUTIONANDSAFETYSTANDARDS
TUBO DI ASPIRAZIONE
h2
ALIMENTAZIONE UGELLO
HS= ALTEZZA DI ASPIRAZIONE
DN3
DN1
EN 60034-1 IEC 34-1 CEI 2-3 a1
EN 60 335-1 IEC 335-1 CEI 61-150
DN2
w
SUCTION INLET NOZZLE FEED INLET
EJECTOR
a2
De
TYPE Single-phase Three-phase D N p D N 1 D N 2 D N 3 D N 4 D e DN4 FOOT VALVE
DNp
JDWm 1C JDWm 1B JDWm 1A JDWm 2
JDW 1C JDW 1B JDW 1A JDW 2
4" 4" 3" 4" 4"
11/4" 11/4" 1" 11/4" 11/4"
1" 1" 1" 1" 1"
1" 1" 3/4" 1" 1"
1" 1" 1" 1" 1"
a
96 69.5 96 69.5 70 96 69.5 96 75
DIMENSIONS mm h h1 h2 n
a1
a2
f
46 46 46 46 46
148 148 130 148 148
350 350 350 434
181 92 201 92 201 92 242 108
181 181 181 207
180 180 180 206
n1 144 144 144 164
w
s
kg* 1~ 3~
24 10 14.3 14.3 24 10 14.6 14.6 10 24 10 15.7 14.7 22 10 23.9 22.0 (*weight with ejector)
JDW self-priming electropumps for 2" wells (with immersed ejector)
PERFORMANCE DATA AT n= 2900 1/min
TYPE
HS
POWER
0
Three-phase
Single-phase JDWm 1C -2” JDWm 1B -2” JDWm 1A -2” JDWm 2 -2” JDWm 1C -2” JDWm 1B -2” JDWm 1A -2” JDWm 2 -2” JDWm 1C -2” JDWm 1B -2” JDWm 1A -2” JDWm 2 -2” JDWm 1C -2” JDWm 1B -2” JDWm 1A -2” JDWm 2 -2” JDWm 1B -2” JDWm 1A -2” JDWm 2 -2” JDWm 2 -2” JDWm 2 -2”
JDW 1C JDW 1B JDW 1A JDW 2 JDW 1C JDW 1B JDW 1A JDW 2 JDW 1C JDW 1B JDW 1A JDW 2 JDW 1C JDW 1B JDW 1A JDW 2 JDW 1B JDW 1A JDW 2 JDW 2 JDW 2
-2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2” -2”
kW
HP
0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.50 0.60 0.75 1.1 0.60 0.75 1.1 1.1 1.1
0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.70 0.85 1 1.5 0.85 1 1.5 1.5 1.5
120
240
360
FLOW RATE LITRES/HOUR 480 600 720
840
960
1080
1200
19 24 28 48
17 21 25 44
19 23 40
14 16 36
34
TOTAL MANOMETRIC HEAD IN METRES
metres 46 50 54 85 34 38 40 71 28 32 35 64 23 27 28 56 21 23 51 41 36
15
20
25
30
35 40 45
42 46 50 78 29 33 35 63 24 28 31 59 18 22 24 50 15 18 45 36 30
37 42 46 74 24 29 31 58 20 25 28 55 13 18 21 46 15 41 33
34 39 43 70 21 26 28 54 18 23 26 51
30 35 39 66 18 23 25 50 15 20 23 47
28 32 36 61 16 21 23 46 13 17 20 43
25 30 34 57 13 18 20 43
22 27 31 53 11 16 18 39
14 17 39
36
15 17 42
38
34
31
37
33
Tolerance of the performance curves according to EN ISO 9906 App.
HS = Suction height
DIMENSIONSANDWEIGHTS
A.
f a
HS= ALTEZZA DI ASPIRAZIONE
h1
a1
h2
h
DN2
s
w
n1 n
SUCTION INLET NOZZLE FEED INLET
DN1
EJECTOR
a2
De
TYPE GASKETS
DN3 FOOT VALVE
DNp
Single-phase Three-phase D N p D N 1 D N 2 D N 3 D e JDWm 1C JDWm 1B JDWm 1A JDWm 2
JDW 1C JDW 1B JDW 1A JDW 2
4" 4" 2" 4" 4"
11/4" 11/4" 11/4" 11/4" 11/4"
1" 1" 1" 1" 1"
1" 1" 1" 1" 1"
a
a1
a2
f
96 69.5 46 96 132.5 46 49 46 96 69.5 46 96 138 46
148 148 123 148 148
350 460 350 540
DIMENSIONS mm h h1 h2 n
n1
w
s
181 92 201 92 201 92 242 108
144 144 144 164
24 24 24 22
10 10 10 10 10
181 181 181 207
180 180 180 206
kg* 1~ 3~ 15.9 16.2 17.3 25.5
15.9 16.2 16.3 23.2
(*weight with ejector and adaptor)
self-priming multi-impeller pumps
New self-priming pumps, silentrunning, reliable, high-yield, patented.
RANGEOFPERFORMANCE Flow rate up to 200 l/min (12 m3/h) Head up to 120 m
GUARANTEE YEARS according our general termsterms of sale. of sale. GUARANTEE 12 YEAR subject toto our general CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 40°C Environment temperature up to + 40°C
● ● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
PUMP BODY: cast iron and stainless steel AISI 304 (cast iron up to 0.75 kW), with threaded inlets ISO 228/1. IMPELLERS: technopolymer (certified for drinking water). MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104 MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. PLURIJETm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding. PLURIJET: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL.
USESANDINSTALLATIONS
EXECUTIONSONREQUEST
They are recommended for sucking up clean water, even in the presence of air mixed with the pumped liquid and liquids that are chemically non
⇒ ⇒
aggressive for the materials of which the pump is made. PLURIJET SELF-PRIMING PUMPS ARE DESIGNED FOR SUCKING UP WATER, EVEN IN THE PRESENCE OF AIR MIXED WITH THE PUMPED LIQUID. FOR THEIR SILENT RUNNING, RELIABILITY AND LOW ENERGY CONSUMPTION THEY ARE RECOMMENDED FOR DOMESTIC AND CIVIL USE, IN PARTICULAR FOR THE PRESSURISATION AND DISTRIBUTION OF WATER IN COMBINATION WITH AUTOCLAVES, FOR RECOVERY OF RAINWATER, IRRIGATION SYSTEMS, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
execution in stainless steel EN 10088-3 - 1.4401 (AISI 316) other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PLURIJET 6/90
Head H
(metres)
5/90
4/80 3/80
Flow rate Q
TYPE
POWER
Single-phase
Three-phase
kW
PLURIJETm 3/80 PLURIJETm 4/80 PLURIJETm 5/90 PLURIJETm 6/90
PLURIJET 3/80 PLURIJET 4/80 PLURIJET 5/90 PLURIJET 6/90
0.45 0.60 1.1 1.5
m3/h
0
0.3
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
l/min
0 38 50 83 100
5 36 48 82 99
10 34.5 46.5 80 96
20 32 43 76 91.5
30 29 38.5 71 85
40 25 33.5 65 78
50 20 28 59 71
60 15.5 22.5 53 64
70 10.5 16.5 47 56
80 5 10 40 48
Q
HP
0.60 0.85 H metres 1.5 2
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
PLURIJET 80
PLURIJET 90
f
n
a
f
DN2
TYPE Single-phase Three-phase
PLURIJET 3/80 PLURIJET 4/80 PLURIJET 5/90 PLURIJET 6/90
h
h2 h1
DN1
h2 h1 h
DN1
s
w
PLURIJETm 3/80 PLURIJETm 4/80 PLURIJETm 5/90 PLURIJETm 6/90
n
DN2
f
a
INLETS DN1
DN2
1" 1" 1" 11/4" 11/4" 11/4"
1" 1" 1" 1" 1" 1"
a 110 135 69 69 69
f 334 367/359 634 665
h 172 172 172 234 230 234
s
w
DIMENSIONS mm h1 h2 n 134 38 158 134 38 158 134 38 158 166 46 185 153 46 185 166 46 185
n1
kg n1 116 116 116 145 145 145
w 22 2 304 335
s 9 9 9 10 10 10
1~ 9.4 10.8 25.5 27.5
3~ 8.9 10.2 23.5 27.0
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
110 PLURIJET
100
6/130
90 5/130
Head H
(metres)
80 70
4/130
60 3/130
50
4/100
40
3/100
30 20 10 0 Flow rate Q
TYPE
POWER
Single-phase
Three-phase
kW
PLURIJETm 3/100 PLURIJETm 4/100 PLURIJETm 3/130 PLURIJETm 4/130 PLURIJETm 5/130
PLURIJET 3/100 PLURIJET 4/100 PLURIJET 3/130 PLURIJET 4/130 PLURIJET 5/130 PLURIJET 6/130
0.60 0.75 1.1 1.5 1.8 2.2
–––
m3/h
Q
HP
l/min
0.85 1 1.5 H metres 2 2.5 3
0
0.3
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
0
5
36 46 50 66 83 100
35.5 45 49.5 66 82.5 99
10
20
30
40
50
60
70
35 43 49 65 81 98
33.5 42 48 64 80 96
32 40 47 62 78 94
30 38 45.5 60.5 75.5 91
28 35.5 44 58.5 73 88
26 33 42.5 56.5 70.5 85
23 30 40.5 54 67.5 81
Q = Flow rate H = Total manometric head
6.0
7.2
7.8
80
100
120
130
20 26.5 38.5 51 64 77
13.5 19 34 45 56.5 68
5 10 28 37 46.5 56
5 25 33 41 50
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
PLURIJET 100
PLURIJET 130
n
f
n
f
a DN2
h2
h2 w
n1
TYPE Single-phase Three-phase
DN1
DN2
PLURIJETm 3/100 PLURIJET 3/100 PLURIJETm 4/100 PLURIJET 4/100 PLURIJETm 3/130 PLURIJET 3/130 PLURIJETm 4/130 PLURIJET 4/130 PLURIJETm 5/130 PLURIJET 5/130 ––– PLURIJET 6/130
1" 1" 1" 11/4" 11/4" 111/4" 1/4" 11/4"
1" 1" 1" 1" 1" 1" 1" 1"
h1
h1
h
h
DN1
DN1
DN2
s
a
INLETS a 110 135 69 69 69 69 69
f 342/334 378 571 602 634 665
h 172 191 234 234 230 234 234
s
w
DIMENSIONS mm h1 h2 n 134 38 158 134 158 134 61 158 166 46 185 166 46 185 153 46 185 166 46 185 166 46 185
n1
kg n1 116 116 116 145 145 145 145 145
w 22 2 241 272 304 335
s 9 9 9 10 10 10 10 10
1~ 10.2 13.4 23.5 25.9 27.5 -
3~ 9.4 12.3 21.6 25.0 27.0 29.0
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PLURIJET
90
6/200
80 5/200
Head H
(metres)
70 60
4/200
50 3/200
40 30 20 10 0 Flow rate Q
TYPE Single-phase
POWER
Three-phase
PLURIJETm 3/200 PLURIJET 3/200 PLURIJETm 4/200 PLURIJET 4/200 PLURIJETm 5/200 PLURIJET 5/200 ––– PLURIJET 6/200
Q
m3/h
0
1.2
2.4
3.0
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12.0
20
40
50
60
80
100
120
140
160
180
200
44 58 73 88
43 57 71.5 86
42 56 70 84
41 54.5 68 82
39 52 65 78
36 48 60 72
32.5 43 54 65
29 38.5 48 58
25 33 41.5 50
20 26.5 33 40
15 20 25 30
kW
HP
l/min
0
1.1 1.5 1.8 2.2
1.5 2 H metres 2.5 3
45 60 75 90
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
n
h1
h
DN1
h2
DN2
a
s
w
TYPE Single-phase Three-phase
DN1
DN2
PLURIJETm 3/200 PLURIJET 3/200 PLURIJETm 4/200 PLURIJET 4/200 PLURIJETm 5/200 PLURIJET 5/200 PLURIJET 6/200 –––
11/4" 1/4" 111/4 " 11/4" 11/4"
1" 1" 1" 1" 1"
n1
INLETS a 69 69 69 69 69
f 571 602 634 665
h 234 234 230 234 234
DIMENSIONS mm h1 h2 n 166 46 185 166 46 185 153 46 185 166 46 185 166 46 185
kg n1 145 145 145 145 145
w 241 272 304 335
s 10 10 10 10 10
1~ 23.5 25.9 27.5 -
3~ 21.6 25.0 27.0 29.0
self-priming electropumps with liquid ring
RANGEOFPERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 51 m
subject to to our general terms GUARANTEE 1 YEAR GUARANTEE 2 YEARS according our general terms of sale.of sale.
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 90°C (+55°C for diesel fuel/mazut) Environment temperature up to + 40°C
●
● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3 ●
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING DIESEL FUEL/MAZUT, CLEAN WATER WITHOUT ABRASIVE PARTICLES AND LIQUIDS THAT ARE CHEMICALLY NON AGGRESSIVE FOR THE MATERIALS OF WHICH THE PUMP IS MADE. THANKS TO THE SPECIFIC OPERATING PRINCIPLE THEY ARE A GOOD SOLUTION IN ALL CASES WHERE A COMPACT SELF-PRIMING PUMP IS NEEDED OR WHERE THE FLOW OF LIQUID IS POOR OR IRREGULAR OR MIXED WITH AIR. The pumps must be installed in enclosed places, or at least protected against inclement weather.
●
PUMP BODY: cast iron, with threaded inlets ISO 228/1. LANTERN (patent nº 1289150): aluminium with front shim disk in brass; reduces starting difficulties due to blockage of the impeller after long periods of inactivity. IMPELLER: brass of the star type with open radial vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - VITON. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. CKm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . CK: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒ ⇒
CKm/INT electropumps with switch and power cable with Schuko plug CKm 50-BP/NZ electropumps with aluminium spray gun and 4 metre hose reinforced with a steel spiral . special mechanical seal other voltages or frequency 60 Hz protection IP 55
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
CK90E
Head H
(metres)
CK80E
CK50
CK50BP
Flow rate Q
TYPE Single-phase CKm 50 CKm 50-BP CKm 80-E CKm 90-E
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
0.50 0.33 H metres 0.85 1
35 20 48 51
31 20 46 49
27 20 42 45
24 20 38 41
20 20 34 37
16 16.5 30 33
13 13 26 29
9 9 22 25
5 5 18 21
10 13
POWER
Three-phase CK 50 CK 50-BP CK 80-E CK 90-E
kW
0.37 0.25 0.60 0.75
Q
HP
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
i
f
h1
h3
h
h2
DN1
DN2
a
TYPE Single-phase Three-phase CKm 50 CK 50 CKm 50-BP CK 50-BP CKm 80-E CK 80-E CKm 90-E CK 90-E
w
n1 n
s
m
INLETS DN1
DN2
3/4" 3/4" 3/4" 1" 1" 1"
3/4" 3/4" 3/4" 1" 1" 1"
a 41 44 50 50 50
f 260 263 296 296 296
h 159 159 159 179 179 179
h1 128 128 128 136 136 136
h2 25 25 25 31 31 31
DIMENSIONS mm h3 i 153 75 153 75 153 75 167 81 167 81 167 81
kg m 80 80 80 90 90 90
n 120 120 120 134 134 134
n1 100 100 100 112 112 112
w 69 69 69 77 77 77
s 7 7 7 7 7
1~ 7.3 7.3 7.3 11.6 11.8
3~ 6.8 6.8 6.8 10.8 11.0
self-priming electropumps with liquid ring withdoubleanti-blockingfrontshimdisk
Priming safety and guaranteed starting, even after long periods of inactivity, thanks to two anti-blocking shim disks, in front of the impeller, which prevent the formation of rust.
RANGEOFPERFORMANCE Flow rate up to 50 l/min (3 m3/h) Head up to 54 m
subject to to our terms GUARANTEE 1 YEAR GUARANTEE 2 YEARS according our general general terms of sale.of sale.
CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 90°C (+55°C for diesel fuel/mazut) Environment temperature up to + 40°C
●
●
EXECUTIONANDSAFETYSTANDARDS
● ●
EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER OR LIQUIDS WITHOUT ABRASIVE PARTICLES AND LIQUIDS THAT ARE CHEMICALLY NON AGGRESSIVE FOR THE MATERIALS OF WHICH THE PUMP IS MADE. THANKS TO THE SPECIFIC OPERATING PRINCIPLE THEY ARE A GOOD SOLUTION IN ALL CASES WHERE A COMPACT SELFPRIMING PUMP IS NEEDED OR WHERE THE FLOW OF LIQUID IS POOR OR IRREGULAR OR MIXED WITH AIR. The pumps must be installed in enclosed places, or at least protected against inclement weather.
●
● ●
PUMP BODY: cast iron, with shim surface in stainless steel to prevent blocking of the impeller due to oxidation. It has threaded inlets ISO 228/1. LANTERN (patent nº 1289150): aluminium with front shim disk in brass; eliminates starting difficulties due to blockage of the impeller after long periods of inactivity. IMPELLER: brass of the star type with open radial vanes. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - VITON. ELECTRIC MOTOR: the pumps are coupled to a PEDROLLO electric motor with specially calculated dimensions, silent-running, closed, with external ventilation, suitable for continuous duty. CKRm: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding . CKR: three-phase 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44. REGISTERED MODEL
EXECUTIONONREQUEST
⇒ ⇒ ⇒ ⇒
CKRm/INT electropumps with switch and power cable with Schuko plug special mechanical seal other voltages or frequency 60 Hz protection IP 55
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
CKR100E CKR90E
Head H
(metres)
CKR80E
Flow rate Q
TYPE Single-phase CKRm 80-E CKRm 90-E CKRm 100-E
POWER
Three-phase CKR 80-E CKR 90-E CKR 100-E
kW
0.60 0.75 0.90
Q
HP
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
0.85 1 H metres 1.25
48 51 54
46 49 52
42 45 48
38 41 44
34 37 40
30 33 36
26 29 32
22 25 28
18 21 24
10 13 16
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
i
f
h1
h3
h
h2
DN1
DN2
a
TYPE Single-phase Three-phase CKRm 80-E CKR 80-E CKRm 90-E CKR 90-E CKRm 100-E CKR 100-E
w
n1 n
s
m
INLETS DN1
DN2
1"
1"
1"
1"
1"
1"
a 50 50 50
f 296 296 296
h 179 179 179
h1 136 136 136
h2 31 31 31
DIMENSIONS mm h3 i m 167 81 90 167 81 90 167 81 90
kg n 134 134 134
n1 112 112 112
w 77 77 77
s 7 7 7
1~ 11.6 11.8 11.8
3~ 10.8 11.0 12.0
electropumps with bronze pump body
RANGE OF PERFORMANCE Flow rate up to 90 l/min (5.4 m3/h) Head up to 55 m.
GUARANTEE YEARS according our general terms of sale. of sale. subject totoour general terms GUARANTEE 12 YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Liquid temperature up to + 90°C Environment temperature up to + 40°C
● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS
●
EN 60034-1 IEC 34-1 CEI 2-3
●
PUMP BODY: bronze, with threaded inlets ISO 228/1. LANTERN (patent nº 1289150) PK-Bz, PQ-Bz: aluminium with front shim disk in brass. PUMP BODY COVER: CP-Bz: stainless steel AISI 316. IMPELLER : PK-Bz, PQ-Bz: brass. CP-Bz: stainless steel AISI 316 MOTOR SHAFT: stainless steel AISI 316. MECHANICAL SEAL: ceramic - graphite - VITON. ELECTRIC MOTOR : induction motor, for continuous duty. Single-phase: 230 V - 50 Hz with condenser and thermal overload protector built into the winding . Three-phase: 230/400 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 44.
EXECUTIONSONREQUEST USESANDINSTALLATIONS They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made.THE CONSTRUCTIVE CHARACTERISTICS OF THESE PUMPS ARE A SURE GUARANTEE AGAINST RUST AND OXIDATION. THEIR COMPACTNESS AND HYDRAULIC OPERATION CURVES SUGGEST THEIR USE IN THE INDUSTRIAL FIELD, IN COOLING, CONDITIONING, ETC. The pumps must be installed in enclosed places, or at least protected against inclement weather.
⇒ ⇒ ⇒ ⇒
special mechanical seal other voltages or frequency 60 Hz protection IP 55 for liquids with higher temperatures for environments with higher temperatures
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 1
2 1
3 2
4
5
3
6 5
4
7
8
9
6
10
7
11
8
12 10
9
13 11
PK60Bz
Head H
(metres)
PK65Bz
Flow rate Q
TYPE Single-phase PKm 60-Bz PKm 65-Bz
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
0.50 H metres 0.70
40 55
38 50
33.5 45.5
29 40.5
24 36
19.5 31
15 27
10 22
5 17
8
POWER
Three-phase PK 60-Bz PK 65-Bz
kW
0.37 0.50
Q
HP
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
i
h1
DN1
h3
h
h2
DN2
a
TYPE Single-phase Three-phase PKm 60-Bz PK 60-Bz PKm 65-Bz PK 65-Bz
n1 n
s
m
w
INLETS DN1
DN2
1" 1" 1"
1" 1" 1"
a 42 48
f 243 258/250
h 152 152 152
h1 63 63 63
h2 75 80
DIMENSIONS mm h3 i m 138 20 80 20 80 143 20 80
kg n 120 120 120
n1 100 100 100
w 55 55 55
s 7 7 7
1~ 5.7 8.1
3~ 5.7 6.8
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 1
2 1
3 2
4
5
3
6 5
4
7
8
9
6
10
7
11
8
12 10
9
13 11
PQ60Bz
Head H
(metres)
PQ65Bz
Flow rate Q
TYPE Single-phase PQm 60-Bz PQm 65-Bz
POWER
Three-phase PQ 60-Bz PQ 65-Bz
kW
0.37 0.50
Q
0
m3/h
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
0.50 H metres 0.70
40 55
38 50
33.5 45.5
29 40.5
24 36
19.5 31
15 27
10 22
5 17
8
HP
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
f
i
h1
h3
h
DN1
h2
DN2
n1
s a
TYPE Single-phase Three-phase PQm 60-Bz PQ 60-Bz PQm 65-Bz PQ 65-Bz
w
m
n
INLETS DN1
DN2
1" 1" 1"
1" 1" 1"
a 22 22 22
f h 223 152 152 234/227 152
h1 108 113
h2 30 30 30
DIMENSIONS mm h3 i m 138 78 80 78 80 143 78 80
kg n 120 120 120
n1 100 100 100
w 55 57
s 7 7 7
1~ 5.5 7.4
3~ 5.5 6.6
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
CP130Bz
Head H
(metres)
CP158Bz
Flow rate Q
TYPE Single-phase CPm 130-Bz CPm 158-Bz
POWER
Trifase CP 130-Bz CP 158-Bz
kW
0.37 0.75
Q
m3/h
0
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
l/min
0
10
20
30
40
50
60
70
80
90
0.50 H metres 1
23 36
22 34
21 33.5
20 33
19 32.5
18 31.5
17 30
15.5 28.5
14 27
25
HP
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS f
n
a
h1
DN1
h
h2
DN2
s
w n1
TYPE Single-phase Three-phase CPm 130-Bz CPm 158-Bz
CP 130-Bz CP 158-Bz
INLETS DN1
DN2
a
f
h
h1
1" 1" 1"
1" 1" 1"
42 42 42
259 285
205 240
82 92
DIMENSIONS mm h2 n 123 148
165 190
kg n1
w
s
1~
3~
135 160
41 38
10 10 10
8.5 12.8
8.3 12.3
4"submergedelectropumpwithperipheralimpeller
Stainless steel submerged pump with peripheral impeller andanti-blockingsystem. Standardversionsuppliedwitha10-metrepowercableand built-in condenser, for simple and easy installation.
RANGE OF PERFORMANCE Flow rate up to 50 l/min (3.0 m3/h) Head up to 68 m
CONSTRUCTIONCHARACTERISTICS ● ●
LIMITS OF USE Depth of use up to 40 m Liquid temperature up to + 40°C EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
subject to to our terms GUARANTEE 1 YEAR GUARANTEE 2 YEARS according ourgeneral general terms of sale.of sale.
EN 60034-1 IEC 34-1 CEI 2-3
● ● ● ●
● ●
DELIVERY BODY: stainless steel AISI 304. PUMP BODY WITH DOUBLE ANTI-BLOCKING SHIM DISK IN FRONT OF THE IMPELLER; (patented). IMPELLER: brass, type with radial peripheral vanes. MOTOR JACKET: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MOTOR: submersible, asynchronous, single-phase, for continuous duty (without oil, rewindable). 4SKm: single-phase 220÷240 V - 50 Hz. INSULATION: class F. ● PROTEZIONE: IP 68. MECHANICAL SEAL: ceramic - graphite - NBR.
THE ELECTROPUMP IS COMPLETE WITH:
USESANDINSTALLATIONS It is recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made. FOR ITS COMPACTNESS AND ECONOMY IT IS RECOMMENDED FOR DOMESTIC USE AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH SMALL AUTOCLAVES, FOR IRRIGATION, ETC.
4SK m 4SKm
Thermal overload protector. Condenser built into the inside of the motor. Flat type 10 metre power cable.
EXECUTIONONREQUEST
⇒ ⇒
20 metre power cable other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Head H
(metres)
4SKm100E
Flow rate Q
TYPE
POWER
Single-phase 4SKm 100E
kW
HP
0.75
1
Q
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
l/min
0
5
10
15
20
25
30
35
40
50
68
62
55
49
43
37
30
24
17
5
H metres
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typical installation DN
h
Connection for safety cable
The 4SK pump may be installed in boreholes with a diameter not less than 4" (100 mm). The electropump is lowered into the borehole by means of the delivery pipe to such a depth as to guarantee its complete immersion (min. 50 cm and at least one metre from the bottom). It is good practice to secure the pump by means of a stainless steel or nylon cable, connected to the
Ø
anchoring points on the delivery body.
TYPE Single-phase
INLET DN
Ø
DIMENSIONS mm h
kg
4SKm 100E
1"
99.5
500
13.1
5"submergedelectropumpswithperipheralimpeller withanti-blockingshimdisks
Submergedpumpswithperipheralimpellerandpatentedantiblockingsystem(guaranteespumpoperationevenafterlong periodsofinactivity).
RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 77 m LIMITS OF USE
subject to our general terms of sale. GUARANTEE 1 YEAR GUARANTEE 2 YEARS according to our general terms of sale.
CONSTRUCTIONCHARACTERISTICS ● ●
Depth of use up to 40 m Liquid temperature up to + 40°C
● ● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS They are recommended for pumping clean water without abrasive particles and liquids that are chemically non aggressive for the materials of which the pump is made. FOR THEIR COMPACTNESS AND ECONOMY THEY ARE RECOMMENDED FOR DOMESTIC USE AND IN PARTICULAR FOR DISTRIBUTING WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATION, ETC.
● ●
DELIVERY BODY: brass with double anti-blocking shim disk in front of the impeller. IMPELLER: brass, type with radial peripheral vanes. MOTOR JACKET: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MOTOR: submersible, asynchronous, single-phase, for continuous duty, may be removed and rewound, in an oil bath. 5SKm: single-phase 220÷240 V - 50 Hz. INSULATION: class F. ● PROTECTION IP 68. MECHANICAL SEAL: stainless steel - graphite - NBR.
THE ELECTROPUMP IS COMPLETE WITH: 5SK m 5SKm
Checkvalve . 20 metre neoprene power cable type “H07 RN-F” with removable connector. Electric panel with bipolar switch, condenser and motor protector with manual reset.
EXECUTION ON REQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
5SKm150
5SKm100M
Head H
(metres)
5SKm100
Flow rate Q
TYPE
POWER
Single-phase 5SKm 100 5SKm 100M 5SKm 150
Q
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.0
3.6
4.2
4.8
5
10
15
20
25
30
35
40
50
60
70
80
70 40 50
63.5 37.5 47.5
57 35 45
50 32.5 42
43.5 30 39
37 27.5 37
30 25 34
23 22.5 31
10 17.5 26
13 21
8 15
3 10
kW
HP
l/min
0
0.75 0.75 1.1
1 1 H metres 1.5
77 42 53
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typical installation
DN
Connection for safety cable
CONTROL PANEL
5SK pumps may be installed in
h
d
boreholes with a diameter not less than 5" (125 mm). The electropump is lowered into the borehole by means of
b
the delivery pipe to such a depth as to guarantee its complete immersion (min. 50 cm and at least one metre from the bottom).
a
It is good practice to secure the pump
c
by means of a stainless steel or nylon
Ø
cable, fixed to the holes provided on the delivery body.
TYPE Single-phase 5SKm 100 5SKm 100M 5SKm 150
INLET DN
11/4"
11/4" 11/4"
Ø 120 120 120
h 313 313 313
DIMENSIONS a 200 81 200
mm b 81 200 81
kg c 85 66 85
d 66 85 66
14.9 16.4 16.4
4"submergedenblocelectropumps sand-resistant
4”submergedenblocelectropumpsdesignedwiththeaim of obtaining a new product that is more economic and reliable.Theyaresuppliedcompletewithcondenser,inside the motor, and with a 20 metre power cable, for easy and inexpensiveinstallation.
RANGE OF PERFORMANCE Flow rate up to 150 l/min (9 m3/h) Head up to 135 m
● ● ● ●
LIMITS OF USE Liquid temperature up to +30°C Maximum sand content 150 g/m3 Depth of use up to 40 m
●
● ● ●
EXECUTIONANDSAFETYSTANDARDS ●
EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ● ●
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT OF UP TO 150 g/m3. FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE RECOMMENDED FOR USE IN THE DOMESTIC SECTOR, FOR THE AUTOMATIC DISTRIBUTION OF WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATION, ETC.
our general terms GUARANTEE 12YEAR GUARANTEE YEARSsubject accordingto to our general terms of sale. of sale.
JACKET: stainless steel AISI 304. IMPELLERS AND DIFFUSORS: technopolymer. DIFFUSOR CONTAINER: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: fixed part in special technopolymer and bush rotating with the shaft in stainless steel AISI 316 coated with chrome oxide to resist sand. DRIVE COUPLING: stainless steel AISI 316L. SCREWS AND CABLE COVER : stainless steel AISI 304. MOTOR SHAFT: stainless steel AISI 316 (EN 10088-3 - 1.4104 up to 0.75 kW). MOTOR: submersible for continuous duty (without oil, rewindable). 4BLOCKm:single-phase 220÷240 V - 50 Hz. 4BLOCK: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68. CHECK VALVE: built into the delivery body. DOUBLE MECHANICAL SEAL: ceramic - graphite - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water).
THE ELECTROPUMPS ARE COMPLETE WITH: 4BLOCKm
(single-phase) Motor protector built into the winding. Condenser built into the inside of the motor. 20 metre flat power cable.
4BLOCK
(three-phase) 20 metre flat power cable.
CONSTRUCTIONCHARACTERISTICS ●
DELIVERY BODY:
stainless steel AISI 304 with threaded inlet ISO 228-1.
EXECUTIONS ON REQUEST
⇒ 30 metre power cable ⇒ other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
η=54% 4BLOCK2/20
(metres)
45
4BLOCK2/13
26
Head H
4BLOCK2/10
Flow rate Q
TYPE Single-phase 4BLOCKm 2/10 4BLOCKm 2/13 4BLOCKm 2/20
POWER
Three-phase 4BLOCK 2/10 4BLOCK 2/13 4BLOCK 2/20
kW
0.55 0.75 1.1
HP
Q
m3/h
0
l/min
0.75 1 H metres 1.5
0.6
1.2
0
10
70 90 135
68 88 130
Q = Flow rate H = Total manometric head
1.8
2.4
3.0
3.6
20
30
40
50
60
63 82 122
57 74 111
48 62 93
36 46 71
20 26 39
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typical installation Ø DN
STATIC LEVEL
h
DYNAMIC LEVEL
min 1 metre
TYPE Single-phase Three-phase 4BLOCKm 2/10 4BLOCK 2/10 4BLOCKm 2/13 4BLOCK 2/13 4BLOCKm 2/20 4BLOCK 2/20
INLETS DN
11/4"
11/4" 11/4"
N° stages 10 13 20
DIMENSIONS mm Ø 99.5
kg h 693/668 774/749 987/927
1~ 10.2 11.7 14.9
3~ 9.0 10.6 12.5
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
4BLOCK4/18
η=61%
50
(metres)
4BLOCK4/14
35
Head H
4BLOCK4/9 4BLOCK4/7
Flow rate Q
TYPE
POWER
Single-phase Three-phase 4BLOCKm 4/7 4BLOCK 4/7 4BLOCKm 4/9 4BLOCK 4/9 4BLOCKm 4/14 4BLOCK 4/14 ––––– 4BLOCK 4/18
kW
0.55 0.75 1.1 1.5
HP
Q
m3/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
l/min
0 46 60 92 120
20 44 56 88 112
30 42 54.5 85 109
40 40 52 81 104
50 38 49 76 98
60 35 45 70 90
70 31.5 40.5 63 81
80 27 35 54.5 70
90 23 29 45 58
100 17 23 35 45
0.75 1 H metres 1.5 2
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typical installation
Ø DN
STATIC LEVEL
h
DYNAMIC LEVEL
min 1 metre
TYPE Single-phase Three-phase 4BLOCKm 4/7 4BLOCK 4/7 4BLOCKm 4/9 4BLOCK 4/9 4BLOCKm 4/14 4BLOCK 4/14 ––––– 4BLOCK 4/18
INLETS DN
11/4" 1/4" 111/4 " 11/4" 11/4"
N° stages 7 9 14 18
DIMENSIONS mm Ø 666/641 735/710 99.5 846/786 ––/958
kg h 663/638 732/707 901/841 ––/1014
1~ 9.9 11.3 14.3 -
3~ 8.7 10.2 11.9 15.0
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
η =65%
4BLOCK6/13
55
(metres)
50
Head H
4BLOCK6/9
4BLOCK6/6
4BLOCK6/4
Flow rate Q
TYPE Single-phase 4BLOCKm 6/4 4BLOCKm 6/6 4BLOCKm 6/9 –––––
POWER
Three-phase 4BLOCK 6/4 4BLOCK 6/6 4BLOCK 6/9 4BLOCK 6/13
kW
0.55 0.75 1.1 1.5
Q
0
m3/h
1.5
3.0
4.5
6.0
7.5
9.0
l/min
0
25
50
75
100
125
150
0.75 1 1.5 H metres 2
27 40 61 87
26 38 58 83
24 36 54 78
22 33 50 71
19 29 44 61
15 24 35 49
11 17 26 35
HP
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typical installation
Ø DN
STATIC LEVEL
h
DYNAMIC LEVEL
min 1 metre
TYPE Single-phase Three-phase 4BLOCKm 6/4 4BLOCK 6/4 4BLOCKm 6/6 4BLOCK 6/6 4BLOCKm 6/9 4BLOCK 6/9 ––––– 4BLOCK 6/13
INLETS DN
11/4" 1/4" 111/4 " 11/4" 11/4"
N° stages 4 6 9 13
DIMENSIONS mm Ø 633/608 718/693 99.5 867/807 ––/1012
kg h 629/604 714/689 864/804 ––/1008
1~ 9.7 11.3 13.9 -
3~ 8.5 10.2 11.5 15.4
multi-impellersubmergedelectropumps
An attentive mechanical and fluid-dynamic design has produced SUMO, the best synthesis of performance, low noise, reliability, sturdiness and ease of installation.
RANGE OF PERFORMANCE Flow rate up to 80 l/min (4.8 m3/h) Head up to 105 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Liquid temperature up to +40°C Maximum sand content 50 g/m3 Depth of use up to 20 m below water level
● ●
● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER IN THE DOMESTIC, CIVIL AND AGRICULTURAL FIELD, FOR DISTRIBUTING WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATING GARDENS, BOOSTING PRESSURE, ETC. GUARANTEE 12YEAR subject our general GUARANTEE YEARS accordingto to our general terms terms of sale. of sale.
●
OUTER JACKET AND MOTOR SUPPORT: stainless steel AISI 304 IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). SCREWS AND FILTER: stainless steel AISI 304. MOTOR: submersible asynchronous for continuous duty. SUMOm 2: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW; for the 1.8 kW motor the overload protector is on the outside, on the electric panel, and is of the type with manual reset. SUMO 2: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: SUMO m 2 (single-phase ) Connection box with condenser SUMOm 20 mt power cable type "H07 RN-F" with removable connector and Schuko plug.
SUMO 2
(three-phase ) 20 mt power cable type "H07 RN-F" with removable connector.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒
economy version electropump supplied with 10 metre power cable and condenser, (without connection box) single-phase electropumps with external float switch (SUMOm 2...GE) other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
SUMO2/18
(metres)
SUMO2/15
SUMO2/11
Head H
SUMO2/7
SUMO2/6 SUMO2/5
Flow rate Q
TYPE Single-phase Three-phase SUMOm 2/5 ––– SUMOm 2/6 ––– SUMOm 2/7 SUMO 2/7 SUMOm 2/11 SUMO 2/11 SUMOm 2/15 SUMO 2/15 SUMOm 2/18 SUMO 2/18
POWER kW
Q
HP
0.45 0.55 0.75 1.1 1.5 1.8
m3/h
0
0.6
1.2
1.8
2.4
2.7
3.0
3.3
3.6
3.9
4.2
4.5
4.8
l/min
0
10
20
30
40
45
50
55
60
65
70
75
80
35 46 58 72 87 102
33 44 55 70 83 98
31 41 51 66 78 92
0.6 36 0.75 48 1 H metres 60 1.5 75 2 90 105 2.5
Q = Flow rate H = Total manometric head
28 26 25 23 22 20 18 16 14 37.5 35 34 31 29 26 23 19.5 16 47 44 42 38 36 32 28 23 18 61 58 55 52 48 44 40 35 30 73 70 66 62 58 53 48 44 38 85 82 78 73 68 63 57 50 45 Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Single-phase with float switch
Single-phase with control panel DN
DN Connection for safety cable
Connection for safety cable
SUMO with float switch
b
h
SINGLE-PHASE CONTROL PANEL
h
TYPE Single-phase SUMOm 2/5 - GE SUMOm 2/6 - GE SUMOm 2/7 - GE SUMOm 2/11 - GE SUMOm 2/15 - GE SUMOm 2/18 - GE
a
c Ø
Ø TYPE Single-phase Three-phase SUMOm 2/5 ––– SUMOm 2/6 ––– SUMOm 2/7 SUMO 2/7 SUMOm 2/11 SUMO 2/11 SUMOm 2/15 SUMO 2/15 SUMOm 2/18 SUMO 2/18
INLET DN
11/4" 11/4" 1/4" 111/4 " 11/4" 11/4" 11/4"
N° stages 3 4 5 5 5 6 7
Ø 384 135 482 543 153 648
DIMENSIONS h 384 458 482 543 573 648
mm a 200 200 200 81 200 200 200
kg b 81 81 81 200 81 81 81
c 66 66 66 66 66 66 66
1~ 11.9 14.0 17.3 24.5 25.4 31.2
3~ 15.8 22.8 23.8 27.1
multi-impellersubmergedelectropumps
An attentive mechanical and fluid-dynamic design has produced SUMO, the best synthesis of performance, low noise, reliability, sturdiness and ease of installation.
RANGE OF PERFORMANCE Flow rate up to 120 l/min (7.2 m3/h) Head up to 105 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Liquid temperature up to +40°C Maximum sand content 50 g/m3 Depth of use up to 20 m below water level
● ●
● ●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
●
OUTER JACKET AND MOTOR SUPPORT: stainless steel AISI 304 IMPELLERS AND DIFFUSORS: technopolymer. DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). SCREWS AND FILTER: stainless steel AISI 304. MOTOR: submersible asynchronous for continuous duty. SUMOm 4: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW; for the 1.8 kW motor the overload protector is on the outside, on the electric panel, and is of the type with manual reset. SUMO 4: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTEctION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER IN THE DOMESTIC, CIVIL AND AGRICULTURAL FIELD, FOR DISTRIBUTING WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATING GARDENS, BOOSTING PRESSURE, ETC.
GUARANTEE YEARS accordingto to our general terms of sale. of sale. GUARANTEE 12YEAR subject our general terms
SUMO m 4 (single-phase ) Connection box with condenser SUMOm 20 mt power cable type "H07 RN-F" with removable connector and Schuko plug.
SUMO 4
(three-phase ) 20 mt power cable type "H07 RN-F" with removable connector.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
economy version electropump supplied with 10 metre power cable and condenser, (without connection box) single-phase electropumps with external float switch (SUMOm 2...GE) other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
SUMO4/22
(metres)
SUMO4/18
SUMO4/15
Head H
SUMO4/11 SUMO4/7 SUMO4/6 SUMO4/5
Flow rate Q
TYPE Single-phase Three-phase SUMOm 4/5 ––– SUMOm 4/6 ––– SUMOm 4/7 SUMO 4/7 SUMOm 4/11 SUMO 4/11 SUMOm 4/15 SUMO 4/15 SUMOm 4/18 SUMO 4/18 ––– SUMO 4/22
POWER kW
Q
HP
0.45 0.55 0.75 1.1 1.5 1.8 2.2
m3/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
6.6
7.2
l/min
0
20
30
40
50
60
70
80
90
100
110
120
27 37 48 56 72 85 101
26 36 46 54 69 83 98
25 34.5 44 52 66 79 94
24 32.5 41 50 64 76 90
22.5 30 38 48 60 73 86
20.5 28 35 46 57 68 80
18 25 32 43 53 64 75
15.5 21.5 28 39 48 58 67
13 18.5 24 36 43 52 60
10 14.5 19 31 38 44 52
7 10 14 24 32 38 44
0.6 30 0.75 40 1 H metres 50 1.5 60 2 75 2.5 90 3 105
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Single-phase with float switch
Single-phase with control panel
DN
DN Connection for safety cable
Connection for safety cable
SUMO with float switch
b
h
SINGLE-PHASE CONTROL PANEL
h
TYPE Single-phase SUMOm 4/5 - GE SUMOm 4/6 - GE SUMOm 4/7 - GE SUMOm 4/11 - GE SUMOm 4/15 - GE SUMOm 4/18 - GE
a
c Ø
Ø TYPE Single-phase SUMOm 4/5 SUMOm 4/6 SUMOm 4/7 SUMOm 4/11 SUMOm 4/15 SUMOm 4/18 –––
INLET Three-phase ––– ––– SUMO 4/7 SUMO 4/11 SUMO 4/15 SUMO 4/18 SUMO 4/22
DN
11/4" 11/4" 11/4" 1/4"" 111/4 11/4" 11/4" 11/4"
N° stages 3 4 5 4 5 6 7
Ø 384 135 482 513 543 153 573 648
DIMENSIONS h 384 458 482 513 543 573 648
mm a 200 200 200 81 200 200 200
kg b 81 81 81 200 81 81 81
c 66 66 66 66 66 66 66
1~ 11.9 14.0 17.3 23.4 24.5 25.4 31.5
3~ 15.8 21.4 22.8 23.8 27.1
4"submergedelectropumps sand-resistant
The design of the hydraulic part, the combination of materials used, the front shim disk with the axial movement of the impellers and the possibility of pumping water with sand up to 150g/m3,guaranteethepumpagainstblockageandweardue tosand.
RANGE OF PERFORMANCE Flow rate up to 375 l/min (22.5 m3/h) Head up to 525 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Liquid temperature up to +30°C Maximum sand content 150 g/m3 Starts/hour: 20 at regular intervals
● ● ● ●
EXECUTION AND SAFETY STANDARDS
●
EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3
●
●
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 150 g/m3. FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE RECOMMENDED FOR USE IN THE DOMESTIC, CIVIL AND INDUSTRIAL SECTOR, FOR THE DISTRIBUTION OF WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATION, FOR WASHING SYSTEMS, FOR BOOSTING PRESSURE AND FOR FIRE-FIGHTING SYSTEMS, ETC.
GUARANTEE 12YEAR our general GUARANTEE YEARSsubject accordingto to our general terms terms of sale. of sale.
DELIVERY BODY AND LANTERN: stainless steel AISI 304. NON-RETURN VALVE: stainless steel AISI 304. IMPELLERS AND DIFFUSORS: technopolymer. DIFFUSOR CONTAINER: stainless steel AISI 304. PUMP JACKET: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: fixed part in special technopolymer and bush rotating with the shaft in stainless steel AISI 316 coated with chrome oxide to resist sand. DRIVE COUPLING: stainless steel AISI 316L up to 2.2 kW; stainless steel AISI 304 for higher powers. SCREWS, FILTER AND CABLE COVER : stainless steel AISI 304. MOTOR: Pedrollo 4" submerged electric motor. 4SRm: single-phase220÷230 V - 50 Hz. 4SR: three-phase380÷415 V - 50 Hz. PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: 4SR m (single-phase) Power cable 1.5 metres long (2.5 metres for 4SRm powers higher than 3 kW). With the PEDROLLO motor the condenser is included in the packaging.
4SR
(three-phase) Power cable 1.5 metres long (2.5 metres for powers higher than 3 kW).
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
pumps for water with a sand content higher than 150 g/m3 pumps for sea water Franklin Electric 4" submerged electric motor other voltages or frequency 60 Hz
RANGE OF PERFORMANCE AT n= 2900 1/min
700 600 500 400 300 200
Head H (metres)
100
50 40 30 20
10
5
1 1
5
10
20
30
50
100
200
300
Flow rate Q
DESCRIPTION Borehole diameter in inches Series Flow rate in m3/h in the point of highest yield Single-phase motor Number of stages
4 SR 1 m / 13
500
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
450
400
η=43% 4SR1/64
350
35
300 32
Head H (metres)
4SR1/45
250
4SR1/35
200
150
4SR1/25
4SR1/18
100 4SR1/13
50
4SR1/8
0
Flow rate Q
TYPE Single-phase 4SR1m/8 4SR1m/13 4SR1m/18 4SR1m/25 4SR1m/35 4SR1m/45 –––
Three-phase ––– 4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64
POWER kW
0.25 0.37 0.55 0.75 1.1 1.5 2.2
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
l/min
0
5
10
15
20
25
30
47 77 107 148 206 266 379
45 73 101 140 197 254 362
42 67 93 129 182 234 332
37 60 83 115 161 207 295
31 51 71 98 136 176 250
24 40 55 77 107 137 195
16 26 36 50 70 90 128
0.33 0.50 0.75 H metres 1 1.5 2 3
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
400 η=48% =48%
4SR1.5/60
350
300 4SR1.5/46
31
Head H (metres)
250
28
200
4SR1.5/32
4SR1.5/25
150
4SR1.5/17
100 4SR1.5/13
50
4SR1.5/8 4SR1.5/6
0
Flow rate Q
TYPE Single-phase 4SR1.5m/6 4SR1.5m/8 4SR1.5m/13 4SR1.5m/17 4SR1.5m/25 4SR1.5m/32 ––– –––
Three-phase ––– 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60
POWER kW
0.25 0.37 0.55 0.75 1.1 1.5 2.2 3
Q = Flow rate H = Total manometric head
HP
m3/h
Q
l/min
0.33 0.50 0.75 1 H metres 1.5 2 3 4
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
0
5
10
15
20
25
30
35
40
45
38 50 81 106 156 200 288 375
36 48 78 102 151 193 277 362
34 46 75 98 144 184 265 346
33 44 71 93 136 175 250 328
30 40 66 86 127 162 233 304
27 36 59 78 115 147 211 276
24 32 52 68 100 128 184 241
20 26 43 56 83 106 153 199
15 20 33 43 64 82 117 153
11 14 23 30 45 58 83 108
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
480 4SR2/70
440 η=54%
400
360 4SR2/50
45
Head H (metres)
320
280 4SR2/39
240
200
26
4SR2/27
160 4SR2/20
120 4SR2/13
80
4SR2/10 4SR2/7
40
0
Flow rate Q
TYPE
POWER
Single-phase
Three-phase
kW
4SR2m/7 4SR2m/10 4SR2m/13 4SR2m/20 4SR2m/27 ––– ––– –––
4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70
0.37 0.55 0.75 1.1 1.5 2.2 3 4
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
0.6
1.2
1.8
2.4
3.0
3.6
l/min
0
10
20
30
40
50
60
48 70 90 135 180 260 335 465
46 68 88 130 173 250 322 448
44 63 82 122 164 238 306 427
39 57 74 111 150 216 277 388
33 48 62 93 126 183 235 328
25 36 46 71 96 138 177 248
14 20 26 39 52 75 96 135
0.50 0.75 1 1.5 H metres 2 3 4 5.5
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
560 4SR4/78
520 480 η=61%
440 4SR4/60
400 50
Head H (metres)
360 320
4SR4/46
280 35
240
4SR4/35
200 4SR4/26
160
120
4SR4/18 4SR4/14
80 4SR4/9 4SR4/7
40 0
Flow rate Q
TYPE Single-phase 4SR4m/7 4SR4m/9 4SR4m/14 4SR4m/18 ––– ––– ––– ––– –––
Three-phase 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78
POWER kW
0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
1.2
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
l/min
0
20
30
40
50
60
70
80
90
100
46 60 92 120 170 230 308 405 525
44 56 88 112 162 220 293 385 495
42 55 85 109 157 211 280 370 475
40 52 81 104 150 202 269 350 450
38 49 76 98 141 190 249 325 425
35 45 70 90 130 175 230 300 390
32 40 63 81 116 157 205 270 350
28 35 55 70 101 137 181 235 305
23 29 45 58 84 113 151 195 255
17 23 35 45 63 85 117 155 200
0.75 1 1.5 2 H metres 3 4 5.5 7.5 10
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 5
0
10 5
0
15
20
10
25
15
30
20
35
25
40 30
35
400
feet
η =65%
4SR6/56
375 1200
350 1100
325
55
1000
300 50
4SR6/42
275
900
Head H (metres)
250
800
225 4SR6/31
700
200 600
175 4SR6/23
500
150 125
400
4SR6/17
100 4SR6/13
300
75 4SR6/9
50
200
4SR6/6 4SR6/4
100
25 0
0
25
0 0
1
50 2
3
TYPE Single-phase 4SR6m/4 4SR6m/6 4SR6m/9 4SR6m/13 ––– ––– ––– ––– –––
Three-phase 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56
75 4
POWER kW
0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5
Q = Flow rate H = Total manometric head
HP
m3/h
Q
l/min
0.75 1 1.5 2 3 H metres 4 5.5 7.5 10
100 5
Flow rate Q
150
125
6
7
8
9
10
0
1.5
3.0
4.5
6.0
7.5
9.0
0
25
50
75
100
125
150
27 40 61 87 114 154 210 285 380
26 38 58 83 107 148 200 276 365
24 36 54 78 100 138 186 258 340
22 33 50 71 91 128 170 240 315
19 29 44 61 79 112 149 212 280
15 24 35 49 62 92 121 170 233
11 17 26 35 45 67 86 124 173
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
η=65% 4SR8/42
50
Head H (metres)
4SR8/31
4SR8/23
35
4SR8/17
4SR8/13
4SR8/9 4SR8/7 4SR8/4
Flow rate Q
TYPE Single-phase 4SR8m/4 4SR8m/7 4SR8m/9 ––– ––– ––– ––– –––
Three-phase 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42
POWER
m3/h
Q
kW
HP
0.75 1.1 1.5 2.2 3 4 5.5 7.5
1 1.5 2 3 H metres 4 5.5 7.5 10
Q = Flow rate H = Total manometric head
l/min
0
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12.0
0
40
60
80
100
120
140
160
180
200
27 47 60 87 112 153 205 280
26 46 58 85 110 150 200 272
25 45 57 83 108 146 196 266
24 43 55 80 104 141 190 257
23 41 52 76 99 134 181 244
22 38 48 70 92 124 167 225
20 34 43 63 82 111 149 202
17 29 37 54 70 95 128 175
13 23 30 43 56 76 103 140
10 16 21 30 40 53 72 98
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
4SR10/35
η=63%
4SR10/26 44
Head H (metres)
40
4SR10/20
4SR10/15
4SR10/10
4SR10/7 4SR10/5
Flow rate Q
TYPE Single-phase 4SR10m/5 4SR10m/7 ––– ––– ––– ––– –––
Three-phase 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35
POWER
m3/h
Q
kW
HP
1.1 1.5 2.2 3 4 5.5 7.5
1.5 2 3 4 H metres 5.5 7.5 10
Q = Flow rate H = Total manometric head
l/min
0
3.0
4.5
6.0
7.5
9.0
10.5
12
13.5
15.0
0
50
75
100
125
150
175
200
225
250
33 46 66 98 130 170 230
31 43 62 92 123 160 216
30 41 59 88 118 154 208
28 39 56 84 112 147 197
26 37 53 79 106 138 184
24 34 48 72 96 126 168
21 30 42 64 85 110 148
18 25 36 53 71 94 126
14 20 28 42 56 72 100
10 15 20 30 40 52 70
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
η=58%
4SR12/29
45
40
Head H (metres)
4SR12/22
4SR12/16
4SR12/12
4SR12/9
4SR12/6 4SR12/4
Flow rate Q
TYPE Single-phase 4SR12m/4 4SR12m/6 ––– ––– ––– ––– –––
Three-phase 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29
POWER
m3/h
Q
kW
HP
1.1 1.5 2.2 3 4 5.5 7.5
1.5 2 3 4 H metres 5.5 7.5 10
Q = Flow rate H = Total manometric head
l/min
0
3.0
6.0
9.0
12.0
13.2
14.4
15.6
16.8
18.0
0
50
100
150
200
220
240
260
280
300
25 38 56 75 100 138 182
24 37 55 73 97 135 176
22 19 16 15 14 12 11 8 35 32 28 26 24 21 18 14 52 48 42 39 36 32 27 22 69 64 56 52 48 43 36 29 93 86 75 70 64 57 48 38 127 118 103 96 88 78 66 53 167 155 135 126 116 103 88 71 Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
4SR15/24
η=53%
4SR15/18
40
Head H (metres)
36
4SR15/13
4SR15/10
4SR15/7
4SR15/5
Flow rate Q
TYPE Single-phase 4SR15m/5 ––– ––– ––– ––– –––
Three-phase 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24
POWER Q
m3/h
0
3.0
6.0
9.0
12.0
15.0
18.0
21.0
22.5
l/min
0
50
100
150
200
250
300
350
375
31 44 62 80 112 150
30 42 60 77 108 145
28 40 57 72 102 138
26 37 52 68 95 126
23 32 46 60 85 112
20 27 38 50 71 95
15 20 30 40 55 75
10 13 20 25 37 50
7.5 10 15 19 27 36
kW
HP
1.5 2.2 3 4 5.5 7.5
2 3 4 H metres 5.5 7.5 10
4" submerged electropumps with PEDROLLO motors
DIMENSIONSANDWEIGHTS Ø DN
h2
h
h1
Connection for safety cable
TYPE
INLET
Single-phase
DN
4SR1m/8 - PD 4SR1m/13 - PD 4SR1m/18 - PD 4SR1m/25 - PD 4SR1m/35 - PD 4SR1m/45 - PD 4SR1.5m/6 - PD 4SR1.5m/8 - PD 4SR1.5m/13 - PD 4SR1.5m/17 - PD 4SR1.5m/25 - PD 4SR1.5m/32 - PD 4SR2m/7 - PD 4SR2m/10 - PD 4SR2m/13 - PD 4SR2m/20 - PD 4SR2m/27 - PD 4SR4m/7 - PD 4SR4m/9 - PD 4SR4m/14 - PD 4SR4m/18 - PD 4SR6m/4 - PD 4SR6m/6 - PD 4SR6m/9 - PD 4SR6m/13 - PD 4SR8m/4 - PD 4SR8m/7 - PD 4SR8m/9 - PD 4SR10m/5 - PD 4SR10m/7 - PD 4SR12m/4 - PD 4SR12m/6 - PD 4SR15m/5 - PD
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 1/4"" 111/4 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 310 402 519 648 858 1065 273 310 402 501 648 802 291 347 402 556 685 316 360 470 582 282 342 432 577 282 372 432 417 519 366 470 422
294 294 319 344 404 454 294 294 319 344 404 454 294 319 344 404 454 319 344 404 454 319 344 404 454 344 404 454 404 454 404 454 454
h
kg 1~
604 696 838 992 1262 1519 567 604 721 845 1052 1256 585 666 746 960 1139 635 704 874 1036 601 686 836 1031 626 776 886 821 973 770 924 876
9.3 11.1 13.3 15.8 21.8 25.6 9.0 12.6 14.5 16.7 20.0 23.7 12.4 13.2 15.8 19.0 22.6 13.5 15.3 18.0 21.3 13.1 14.9 17.4 20.8 14.4 16.8 19.6 17.1 20.1 16.7 19.7 19.2
TYPE
INLET
Three-phase
DN
4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24
- PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 402 519 648 858 1065 1516 310 402 501 648 802 1134 1442 291 347 402 556 685 931 1208 1626 316 360 470 582 758 980 1295 1652 2097 282 342 432 577 696 901 1165 1519 2063 282 372 432 577 696 901 1165 1519 417 519 710 1002 1257 1600 2096 366 470 659 811 1053 1358 1752 422 526 720 875 1173 1522
294 294 319 344 404 454 294 294 319 344 404 454 560 294 294 319 344 404 454 560 660 294 319 344 404 454 560 660 745 850 294 319 344 404 454 560 660 745 850 319 344 404 454 560 660 745 850 344 404 454 560 660 745 850 344 404 454 560 660 745 850 404 454 560 660 745 850
h
kg 3~
696 813 967 1202 1469 1970 604 696 820 992 1206 1588 2002 585 641 721 900 1089 1385 1768 2286 610 679 814 986 1212 1540 1955 2397 2947 576 661 776 981 1150 1461 1825 2264 2913 601 716 836 1031 1256 1561 1910 2369 761 923 1164 1562 1917 2345 2946 710 874 1113 1371 1713 2103 2602 826 980 1280 1535 1918 2372
11.1 12.1 14.7 19.4 23.4 30.7 11.6 13.5 15.4 18.3 21.5 26.7 32.4 11.4 12.9 14.5 17.3 20.4 25.2 25.0 25.0 12.5 14.0 16.3 19.1 23.0 26.8 33.9 41.5 56.8 12.1 13.6 15.7 18.6 21.9 25.3 33.6 38.1 47.0 13.1 15.1 17.4 20.8 23.4 24.5 37.2 44.2 15.4 17.9 21.6 25.6 33.9 38.1 53.0 15.0 17.5 21.2 24.1 33.2 38.4 46.5 17.0 20.8 23.1 30.0 36.5 43.0
4" submerged electropumps with FRANKLIN ELECTRIC® motors
DIMENSIONSANDWEIGHTS Ø DN
h2
h
h1
Connection for safety cable
TYPE
INLET
Single-phase
DN
4SR1m/8 - FK 4SR1m/13 - FK 4SR1m/18 - FK 4SR1m/25 - FK 4SR1m/35 - FK 4SR1m/45 - FK 4SR1.5m/6 - FK 4SR1.5m/8 - FK 4SR1.5m/13 - FK 4SR1.5m/17 - FK 4SR1.5m/25 - FK 4SR1.5m/32 - FK 4SR2m/7 - FK 4SR2m/10 - FK 4SR2m/13 - FK 4SR2m/20 - FK 4SR2m/27 - FK 4SR4m/7 - FK 4SR4m/9 - FK 4SR4m/14 - FK 4SR4m/18 - FK 4SR6m/4 - FK 4SR6m/6 - FK 4SR6m/9 - FK 4SR6m/13 - FK 4SR8m/4 - FK 4SR8m/7 - FK 4SR8m/9 - FK 4SR10m/5 - FK 4SR10m/7 - FK 4SR12m/4 - FK 4SR12m/6 - FK 4SR15m/5 - FK
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 1/4"" 111/4 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 310 402 519 648 858 1065 273 310 402 501 648 802 291 347 402 556 685 316 360 470 582 282 342 432 577 282 372 432 417 519 366 470 422
223 242 271 299 327 356 223 242 271 299 327 356 242 271 299 327 356 271 299 327 356 271 299 327 356 299 327 356 327 356 327 356 356
h
kg 1~
533 644 790 947 1185 1421 496 552 673 800 975 1158 533 618 701 883 1041 587 659 797 938 553 641 759 933 581 699 788 744 875 693 826 778
11.2 13.0 15.3 18.1 23.0 25.9 10.9 12.1 14.2 16.6 19.9 23.3 11.9 13.6 15.7 19.8 21.5 13.2 15.2 18.8 20.9 12.8 14.8 18.2 20.4 14.3 17.6 19.2 17.9 19.7 17.5 19.3 18.8
TYPE
INLET
Three-phase
DN
4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24
- FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 111/4 " 1/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 402 519 648 858 1065 1516 310 402 501 648 802 1134 1442 291 347 402 556 685 931 1208 1626 316 360 470 582 758 980 1295 1652 2097 282 342 432 577 696 901 1165 1519 2063 282 372 432 577 696 901 1165 1519 417 519 710 1002 1257 1600 2096 366 470 659 811 1053 1358 1752 422 526 720 875 1173 1522
223 242 271 299 327 356 223 242 271 299 327 356 423 223 242 271 299 327 356 423 584 242 271 299 327 356 423 584 698 774 242 271 299 327 356 423 584 698 774 271 299 327 356 423 584 698 774 299 327 356 423 584 698 774 299 327 356 423 584 698 774 327 356 423 584 698 774
h 625 761 919 1157 1392 1872 533 644 772 947 1129 1490 1865 514 589 673 855 1012 1287 1631 2210 558 631 769 909 1114 1403 1879 2350 2871 524 613 731 904 1052 1324 1749 2217 2837 553 671 759 933 1119 1485 1863 2293 716 846 1066 1425 1841 2298 2870 665 797 1015 1234 1637 2056 2526 749 882 1143 1459 1871 2296
kg 3~ 11.7 13.6 16.2 21.2 24.0 30.5 11.3 13.0 15.2 18.3 20.9 26.5 32.8 11.1 12.5 14.3 17.2 20.4 23.8 22.8 22.8 12.1 13.8 16.2 18.5 21.6 26.9 36.5 45.8 59.8 11.6 13.4 15.5 18.0 20.5 25.4 33.4 42.5 47.2 12.9 15.0 16.8 19.4 23.5 31.0 38.9 47.2 15.2 17.3 20.2 25.7 33.7 42.5 56.0 14.8 16.9 19.8 24.2 31.8 40.1 48.4 16.4 18.7 23.2 30.2 38.2 46.0
4"submergedelectropumps sand-resistant
The design of the hydraulic part, the combination of materials used, the front shim disk with the axial movement of the impellers and the possibility of pumping water with sand up to 150g/m3,guaranteethepumpagainstblockageandweardue tosand.
RANGE OF PERFORMANCE Flow rate up to 375 l/min (22.5 m3/h) Head up to 525 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Liquid temperature up to +30°C Maximum sand content 150 g/m3 Starts/hour: 20 at regular intervals
● ● ● ●
EXECUTION AND SAFETY STANDARDS
●
EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3
●
●
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 150 g/m3. FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE RECOMMENDED FOR USE IN THE DOMESTIC, CIVIL AND INDUSTRIAL SECTOR, FOR THE DISTRIBUTION OF WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATION, FOR WASHING SYSTEMS, FOR BOOSTING PRESSURE AND FOR FIRE-FIGHTING SYSTEMS, ETC.
GUARANTEE 12YEAR our general GUARANTEE YEARSsubject accordingto to our general terms terms of sale. of sale.
DELIVERY BODY AND LANTERN: stainless steel AISI 304. NON-RETURN VALVE: stainless steel AISI 304. IMPELLERS AND DIFFUSORS: technopolymer. DIFFUSOR CONTAINER: stainless steel AISI 304. PUMP JACKET: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: fixed part in special technopolymer and bush rotating with the shaft in stainless steel AISI 316 coated with chrome oxide to resist sand. DRIVE COUPLING: stainless steel AISI 316L up to 2.2 kW; stainless steel AISI 304 for higher powers. SCREWS, FILTER AND CABLE COVER : stainless steel AISI 304. MOTOR: Pedrollo 4" submerged electric motor. 4SRm: single-phase220÷230 V - 50 Hz. 4SR: three-phase380÷415 V - 50 Hz. PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: 4SR m (single-phase) Power cable 1.5 metres long (2.5 metres for 4SRm powers higher than 3 kW). With the PEDROLLO motor the condenser is included in the packaging.
4SR
(three-phase) Power cable 1.5 metres long (2.5 metres for powers higher than 3 kW).
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
pumps for water with a sand content higher than 150 g/m3 pumps for sea water Franklin Electric 4" submerged electric motor other voltages or frequency 60 Hz
RANGE OF PERFORMANCE AT n= 2900 1/min
700 600 500 400 300 200
Head H (metres)
100
50 40 30 20
10
5
1 1
5
10
20
30
50
100
200
300
Flow rate Q
DESCRIPTION Borehole diameter in inches Series Flow rate in m3/h in the point of highest yield Single-phase motor Number of stages
4 SR 1 m / 13
500
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
η=65% 4SR8/42
50
Head H (metres)
4SR8/31
4SR8/23
35
4SR8/17
4SR8/13
4SR8/9 4SR8/7 4SR8/4
Flow rate Q
TYPE Single-phase 4SR8m/4 4SR8m/7 4SR8m/9 ––– ––– ––– ––– –––
Three-phase 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42
POWER
m3/h
Q
kW
HP
0.75 1.1 1.5 2.2 3 4 5.5 7.5
1 1.5 2 3 H metres 4 5.5 7.5 10
Q = Flow rate H = Total manometric head
l/min
0
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12.0
0
40
60
80
100
120
140
160
180
200
27 47 60 87 112 153 205 280
26 46 58 85 110 150 200 272
25 45 57 83 108 146 196 266
24 43 55 80 104 141 190 257
23 41 52 76 99 134 181 244
22 38 48 70 92 124 167 225
20 34 43 63 82 111 149 202
17 29 37 54 70 95 128 175
13 23 30 43 56 76 103 140
10 16 21 30 40 53 72 98
Tolerance of the performance curves according to EN ISO 9906 App. A.
4" submerged electropumps with PEDROLLO motors
DIMENSIONSANDWEIGHTS Ø DN
h2
h
h1
Connection for safety cable
TYPE
INLET
Single-phase
DN
4SR1m/8 - PD 4SR1m/13 - PD 4SR1m/18 - PD 4SR1m/25 - PD 4SR1m/35 - PD 4SR1m/45 - PD 4SR1.5m/6 - PD 4SR1.5m/8 - PD 4SR1.5m/13 - PD 4SR1.5m/17 - PD 4SR1.5m/25 - PD 4SR1.5m/32 - PD 4SR2m/7 - PD 4SR2m/10 - PD 4SR2m/13 - PD 4SR2m/20 - PD 4SR2m/27 - PD 4SR4m/7 - PD 4SR4m/9 - PD 4SR4m/14 - PD 4SR4m/18 - PD 4SR6m/4 - PD 4SR6m/6 - PD 4SR6m/9 - PD 4SR6m/13 - PD 4SR8m/4 - PD 4SR8m/7 - PD 4SR8m/9 - PD 4SR10m/5 - PD 4SR10m/7 - PD 4SR12m/4 - PD 4SR12m/6 - PD 4SR15m/5 - PD
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 1/4"" 111/4 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 310 402 519 648 858 1065 273 310 402 501 648 802 291 347 402 556 685 316 360 470 582 282 342 432 577 282 372 432 417 519 366 470 422
294 294 319 344 404 454 294 294 319 344 404 454 294 319 344 404 454 319 344 404 454 319 344 404 454 344 404 454 404 454 404 454 454
h
kg 1~
604 696 838 992 1262 1519 567 604 721 845 1052 1256 585 666 746 960 1139 635 704 874 1036 601 686 836 1031 626 776 886 821 973 770 924 876
9.3 11.1 13.3 15.8 21.8 25.6 9.0 12.6 14.5 16.7 20.0 23.7 12.4 13.2 15.8 19.0 22.6 13.5 15.3 18.0 21.3 13.1 14.9 17.4 20.8 14.4 16.8 19.6 17.1 20.1 16.7 19.7 19.2
TYPE
INLET
Three-phase
DN
4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24
- PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD - PD
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 402 519 648 858 1065 1516 310 402 501 648 802 1134 1442 291 347 402 556 685 931 1208 1626 316 360 470 582 758 980 1295 1652 2097 282 342 432 577 696 901 1165 1519 2063 282 372 432 577 696 901 1165 1519 417 519 710 1002 1257 1600 2096 366 470 659 811 1053 1358 1752 422 526 720 875 1173 1522
294 294 319 344 404 454 294 294 319 344 404 454 560 294 294 319 344 404 454 560 660 294 319 344 404 454 560 660 745 850 294 319 344 404 454 560 660 745 850 319 344 404 454 560 660 745 850 344 404 454 560 660 745 850 344 404 454 560 660 745 850 404 454 560 660 745 850
h
kg 3~
696 813 967 1202 1469 1970 604 696 820 992 1206 1588 2002 585 641 721 900 1089 1385 1768 2286 610 679 814 986 1212 1540 1955 2397 2947 576 661 776 981 1150 1461 1825 2264 2913 601 716 836 1031 1256 1561 1910 2369 761 923 1164 1562 1917 2345 2946 710 874 1113 1371 1713 2103 2602 826 980 1280 1535 1918 2372
11.1 12.1 14.7 19.4 23.4 30.7 11.6 13.5 15.4 18.3 21.5 26.7 32.4 11.4 12.9 14.5 17.3 20.4 25.2 25.0 25.0 12.5 14.0 16.3 19.1 23.0 26.8 33.9 41.5 56.8 12.1 13.6 15.7 18.6 21.9 25.3 33.6 38.1 47.0 13.1 15.1 17.4 20.8 23.4 24.5 37.2 44.2 15.4 17.9 21.6 25.6 33.9 38.1 53.0 15.0 17.5 21.2 24.1 33.2 38.4 46.5 17.0 20.8 23.1 30.0 36.5 43.0
4" submerged electropumps with FRANKLIN ELECTRIC® motors
DIMENSIONSANDWEIGHTS Ø DN
h2
h
h1
Connection for safety cable
TYPE
INLET
Single-phase
DN
4SR1m/8 - FK 4SR1m/13 - FK 4SR1m/18 - FK 4SR1m/25 - FK 4SR1m/35 - FK 4SR1m/45 - FK 4SR1.5m/6 - FK 4SR1.5m/8 - FK 4SR1.5m/13 - FK 4SR1.5m/17 - FK 4SR1.5m/25 - FK 4SR1.5m/32 - FK 4SR2m/7 - FK 4SR2m/10 - FK 4SR2m/13 - FK 4SR2m/20 - FK 4SR2m/27 - FK 4SR4m/7 - FK 4SR4m/9 - FK 4SR4m/14 - FK 4SR4m/18 - FK 4SR6m/4 - FK 4SR6m/6 - FK 4SR6m/9 - FK 4SR6m/13 - FK 4SR8m/4 - FK 4SR8m/7 - FK 4SR8m/9 - FK 4SR10m/5 - FK 4SR10m/7 - FK 4SR12m/4 - FK 4SR12m/6 - FK 4SR15m/5 - FK
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 1/4"" 111/4 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 310 402 519 648 858 1065 273 310 402 501 648 802 291 347 402 556 685 316 360 470 582 282 342 432 577 282 372 432 417 519 366 470 422
223 242 271 299 327 356 223 242 271 299 327 356 242 271 299 327 356 271 299 327 356 271 299 327 356 299 327 356 327 356 327 356 356
h
kg 1~
533 644 790 947 1185 1421 496 552 673 800 975 1158 533 618 701 883 1041 587 659 797 938 553 641 759 933 581 699 788 744 875 693 826 778
11.2 13.0 15.3 18.1 23.0 25.9 10.9 12.1 14.2 16.6 19.9 23.3 11.9 13.6 15.7 19.8 21.5 13.2 15.2 18.8 20.9 12.8 14.8 18.2 20.4 14.3 17.6 19.2 17.9 19.7 17.5 19.3 18.8
TYPE
INLET
Three-phase
DN
4SR1/13 4SR1/18 4SR1/25 4SR1/35 4SR1/45 4SR1/64 4SR1.5/8 4SR1.5/13 4SR1.5/17 4SR1.5/25 4SR1.5/32 4SR1.5/46 4SR1.5/60 4SR2/7 4SR2/10 4SR2/13 4SR2/20 4SR2/27 4SR2/39 4SR2/50 4SR2/70 4SR4/7 4SR4/9 4SR4/14 4SR4/18 4SR4/26 4SR4/35 4SR4/46 4SR4/60 4SR4/78 4SR6/4 4SR6/6 4SR6/9 4SR6/13 4SR6/17 4SR6/23 4SR6/31 4SR6/42 4SR6/56 4SR8/4 4SR8/7 4SR8/9 4SR8/13 4SR8/17 4SR8/23 4SR8/31 4SR8/42 4SR10/5 4SR10/7 4SR10/10 4SR10/15 4SR10/20 4SR10/26 4SR10/35 4SR12/4 4SR12/6 4SR12/9 4SR12/12 4SR12/16 4SR12/22 4SR12/29 4SR15/5 4SR15/7 4SR15/10 4SR15/13 4SR15/18 4SR15/24
- FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK - FK
11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 111/4 " 1/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
Ø
98
DIMENSIONS mm h1 h2 402 519 648 858 1065 1516 310 402 501 648 802 1134 1442 291 347 402 556 685 931 1208 1626 316 360 470 582 758 980 1295 1652 2097 282 342 432 577 696 901 1165 1519 2063 282 372 432 577 696 901 1165 1519 417 519 710 1002 1257 1600 2096 366 470 659 811 1053 1358 1752 422 526 720 875 1173 1522
223 242 271 299 327 356 223 242 271 299 327 356 423 223 242 271 299 327 356 423 584 242 271 299 327 356 423 584 698 774 242 271 299 327 356 423 584 698 774 271 299 327 356 423 584 698 774 299 327 356 423 584 698 774 299 327 356 423 584 698 774 327 356 423 584 698 774
h 625 761 919 1157 1392 1872 533 644 772 947 1129 1490 1865 514 589 673 855 1012 1287 1631 2210 558 631 769 909 1114 1403 1879 2350 2871 524 613 731 904 1052 1324 1749 2217 2837 553 671 759 933 1119 1485 1863 2293 716 846 1066 1425 1841 2298 2870 665 797 1015 1234 1637 2056 2526 749 882 1143 1459 1871 2296
kg 3~ 11.7 13.6 16.2 21.2 24.0 30.5 11.3 13.0 15.2 18.3 20.9 26.5 32.8 11.1 12.5 14.3 17.2 20.4 23.8 22.8 22.8 12.1 13.8 16.2 18.5 21.6 26.9 36.5 45.8 59.8 11.6 13.4 15.5 18.0 20.5 25.4 33.4 42.5 47.2 12.9 15.0 16.8 19.4 23.5 31.0 38.9 47.2 15.2 17.3 20.2 25.7 33.7 42.5 56.0 14.8 16.9 19.8 24.2 31.8 40.1 48.4 16.4 18.7 23.2 30.2 38.2 46.0
6"submergedelectropumps sand-resistant
An attentive mechanical and fluid-dynamic design has produced the new 6SR. The best synthesis of reliability, high yield and sturdinessguaranteedbythecombinationofmaterialsused.The impeller, inserted in a sturdy stainless steel housing, is made of technopolymer reinforced with glass fibre and covered with special rubber, with high resistance to erosion and corrosion.
RANGE OF PERFORMANCE Flow rate up to 1000 l/min (60 m3/h) Head up to 390 m LIMITS OF USE Liquid temperature up to+30°C Sand content up to 100 g/m3 Starts/hour: 20 at regular intervals EXECUTION AND SAFETY STANDARDS: EN 60034-1 IEC 34-1 CEI 2-3
● ● ● ● ● ● ●
● ● ● ●
●
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 100 g/m3. FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE RECOMMENDED FOR USE IN THE CIVIL, AGRICULTURAL AND INDUSTRIAL SECTOR, FOR THE DISTRIBUTION OF WATER IN COMBINATION WITH AUTOCLAVES, FOR IRRIGATION, FOR BOOSTING PRESSURE AND FOR FIRE-FIGHTING SYSTEMS, ETC.
GUARANTEE 1 2YEAR subject totoour general terms of sale. GUARANTEE YEARS according our general terms of sale.
CONSTRUCTIONCHARACTERISTICS ●
DELIVERY BODY: stainless steel AISI 304 for 6SR36-44, nickel-plated cast iron for 6SR9-12-18-27 with 3" gas threaded inlet UNI ISO 228-1.
NON-RETURN VALVE: stainless steel AISI 304. IMPELLERS: technopolymer reinforced with glass fibre and covered with special rubber DIFFUSOR CONTAINER: stainless steel AISI 304. DIFFUSORS: technopolymer reinforced with glass fibre . PUMP JACKET: stainless steel AISI 304. PUMP SHAFT: stainless steel AISI 304. PUMP BEARINGS: fixed part in special technopolymer and bush rotating with the shaft in stainless steel AISI 316 coated with chrome oxide particularly resistant to sand. LANTERN: nickel-plated cast iron , dimensions to NEMA standards. DRIVE COUPLING: stainless steel AISI 420. SCREWS, FILTER AND CABLE COVER : stainless steel AISI 304. MOTOR: Pedrollo 4" submerged electric motor(up to 3 kW) Pedrollo 6" submerged electric motor(from 4 to 30 kW) 6SR: three-phase380÷415 V - 50 Hz. PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: 6SR
(three-phase) With 6”motor, power cable 4 metres long With 4” motors (power up to 3 kW) length 1.5 metres.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒ ⇒ ⇒
Pedrollo 4" submerged electric motor (up to7.5 kW) Franklin Electric® 4" submerged electric motor (up to7.5 kW) Franklin Electric®6" submerged electric motor pumps with two cable covers for coupling to submerged electric motors with dual voltage / (star/delta) electropumps complete with dual voltage motor: 230/400 V or 400/ 690 V / (star/delta) (from 7.5 kW to 37 kW) other voltages or frequency 60 Hz
RANGE OF PERFORMANCE AT n= 2900 1/min
500
100
Head H (metres)
50
6SR9
10
6SR12 6SR18
5
6SR27 6SR36
6SR44
1 100
200
300
400
500
600
700
Flow rate Q
DESCRIPTION Borehole diameter in inches Series Flow rate in m3/h in the point of highest yield Number of stages
6 SR 9 / 12
800 900
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
350 6SR9/24
300
Ρ=60% 6SR9/21
250 6SR9/17
Head H (metres)
40 35
200 6SR9/12
150 6SR9/9
100
6SR9/7
6SR9/5
50
0
Flow rate Q
TYPE Three-phase 6SR9/5 6SR9/7 6SR9/9 6SR9/12 6SR9/17 6SR9/21 6SR9/24
POWER kW
2.2 3 4 5.5 7.5 9.2 11
Q = Flow rate H = Total manometric head
HP
m3/h
Q
l/min
3 4 5.5 7.5 H metres 10 12.5 15
0
3
6
9
12
15
0
50
100
150
200
250
70 98 126 168 238 294 336
66 61 53 38 15 92 85 74 53 21 119 110 95 68 27 158 146 127 91 36 224 207 180 129 51 278 256 222 160 63 317 293 255 182 72 Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
450 Ρ=67%
400
6SR12/28
6SR12/25
350
52
Head H (metres)
300
47
6SR12/21
6SR12/18
250
6SR12/15
200
6SR12/11
150
6SR12/8
100 6SR12/6 6SR12/4
50
0 0
50
100
150
200
250
300
350
Flow rate Q
TYPE Three-phase 6SR12/4 6SR12/6 6SR12/8 6SR12/11 6SR12/15 6SR12/18 6SR12/21 6SR12/25 6SR12/28
POWER kW
2.2 3 4 5.5 7.5 9.2 11 13 15
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
3.0
6.0
9.0
12.0
15.0
18.0
19.8
l/min
0
50
100
150
200
250
300
330
56 84 111 153 208 250 292 349 390
53 80 106 146 199 239 279 331 371
50 79 100 138 189 225 263 313 350
46 69 91 125 171 205 239 285 319
40 60 80 110 150 180 210 250 280
33 50 66 91 124 149 174 206 231
24 36 47 65 88 106 124 147 165
16 24 32 44 60 72 84 100 112
3 4 5.5 7.5 10 H metres 12.5 15 17.5 20
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Ρ=71%
6SR18/26
58
6SR18/22
Head H (metres)
50
6SR18/18
6SR18/15 6SR18/13 6SR18/11 6SR18/9
6SR18/6 6SR18/4
Flow rate Q
TYPE Three-phase 6SR18/4 6SR18/6 6SR18/9 6SR18/11 6SR18/13 6SR18/15 6SR18/18 6SR18/22 6SR18/26
POWER kW
4 5.5 7.5 9.2 11 13 15 18.5 22
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
3
6
9
12
15
18
21
24
27
l/min
0 54 81 122 149 176 203 244 298 352
50 53.8 80.5 121 148 175 202 242 296 350
100 53 79 119 145.5 172 199 238 291 344
150 51 77 116 141 167 193 231 282 334
200 49 74 111 135 160 185 221 270 320
250 46 69 103 126 149 172 206 252 298
300 42 63 94 115 136 157 188 230 272
350 37 55 83 101 120 138 165 202 239
400 30 45 68 83 98 113 135 165 195
450 22 32 48 59 70 80 96 118 139
5.5 7.5 10 12.5 H metres 15 17.5 20 25 30
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Ρ=68%
6SR27/27
56
Head H (metries
6SR27/20
41
6SR27/17
6SR27/14
6SR27/12
6SR27/10 6SR27/8 6SR27/7
6SR27/5
Flow rate Q
TYPE Three-phase 6SR27/5 6SR27/7 6SR27/8 6SR27/10 6SR27/12 6SR27/14 6SR27/17 6SR27/20 6SR27/27
POWER kW
5.5 7.5 9.2 11 13 15 18.5 22 30
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
6
12
18
24
30
36
l/min
0
100
200
300
400
500
600
68 95 109 136 164 191 231 272 367
66 92 106 132 159 185 224 264 356
62 87 99 124 149 174 211 248 335
57 80 91 114 137 160 194 228 308
50 70 80 100 120 140 170 200 270
37 52 59 74 89 104 126 148 205
22 31 35 44 53 62 75 88 119
7.5 10 12.5 15 17.5 H metres 20 25 30 40
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
300 Ρ=73%
275
6SR36/23
250
6SR36/19
225
59
200 6SR36/15
Head H (metres)
175
6SR36/13
150 6SR36/11
125
6SR36/10 31
100
6SR36/8
75
6SR36/6
50
6SR36/4
25
0 0
100
300
200
400
500
700
600
800
Flow rate Q
TYPE Three-phase 6SR36/4 6SR36/6 6SR36/8 6SR36/10 6SR36/11 6SR36/13 6SR36/15 6SR36/19 6SR36/23
POWER kW
4 5.5 7.5 9.2 11 13 15 18.5 22
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
6
12
18
24
30
36
42
48
l/min
0
100
200
300
400
500
600
700
800
47 70 94 117 129 152 176 222 269
45 67 89 111 123 145 167 212 256
42 63 84 105 115 136 157 199 241
38 57 76 95 105 124 143 181 219
34 51 68 85 93 110 127 161 195
29 44 59 74 81 96 110 140 169
25 37 50 62 68 81 93 118 143
19 29 39 48 53 63 72 92 111
14 20 27 34 37 44 51 65 78
5.5 7.5 10 12.5 15 H metres 17.5 20 25 30
Tolerance of the performance curves according to EN ISO 9906 App. A.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
275 Ρ=73%
250
6SR44/21
225
200
57
6SR44/16
Head H (metres)
175 6SR44/13
150 40
6SR44/11
125 6SR44/9
100
6SR44/8
75
6SR44/6 6SR44/5
50
6SR44/4 6SR44/3
25
0
Flow rate Q
TYPE Three-phase 6SR44/3 6SR44/4 6SR44/5 6SR44/6 6SR44/8 6SR44/9 6SR44/11 6SR44/13 6SR44/16 6SR44/21
POWER kW
4 5.5 7.5 9.2 11 13 15 18.5 22 30
Q = Flow rate H = Total manometric head
HP
Q
m3/h
0
12
18
24
30
36
42
48
54
60
l/min
0 35 47 58 70 93 105 128 151 186 244
200 33 44 54 65 87 98 120 141 174 228
300 31 42 52 62 83 93 114 135 166 218
400 30 40 49 59 79 89 109 128 158 207
500 28 37 46 56 74 83 102 120 148 194
600 26 34 43 51 68 77 94 111 136 179
700 23 31 38 46 61 69 84 99 122 160
800 20 27 33 40 53 60 73 86 106 139
900 17 23 28 34 45 51 62 73 90 118
1000 13 18 22 26 35 39 48 57 70 92
5.5 7.5 10 12.5 15 H metres 17.5 20 25 30 40
Tolerance of the performance curves according to EN ISO 9906 App. A.
6" submerged electropumps with PEDROLLO motors
-A-
versionswith4"motors INLET
137
kg h 1025 1218 1405 1620 1987 982 1175 1362 1577 1901 1188 1360 1596 1364 1575
Ø DN
149.5
h1
54.5 59.2 67.4 80.1 86.3 53.6 60.4 65.7 71.4 83.2 89.5 94.6 49.9 53.7 60.0 66.2 71.0 73.4 84.1 92.3 102.6 53.5 58.6 62.6 68.4 72.5 82.1 90.1 99.9 129.4 55.4 62.1 69.2 76.2 81.2 87.2 93.3 105.4 119.4 54.0 57.4 63.1 68.1 75.2 79.2 85.2 98.2 103.3 136.4
h
146.5
kg h 1375 1535 1827 2030 2191 1331 1491 1740 1900 2060 2269 2429 1158 1274 1435 1551 1713 1835 1995 2229 2462 1278 1414 1497 1633 1819 1955 2173 2392 2887 1422 1678 1934 2190 2333 2594 2850 3362 387 1309 1452 1595 1738 1994 2142 2398 2684 2970 3773
h2
Ø
DIMENSIONS mm h1 h2 776 599 906 629 1168 659 1341 689 1472 719 732 599 862 629 1081 659 1211 689 1341 719 1515 754 1645 784 559 599 645 629 776 659 862 689 994 719 1081 754 1211 784 1385 844 1558 904 649 629 755 659 808 689 914 719 1065 754 1171 784 1329 844 1488 904 1858 1029 823 599 1049 629 1275 659 1501 689 1614 719 1840 754 2066 784 2518 844 2970 904 710 599 823 629 936 659 1049 689 1275 719 1388 754 1614 784 1840 844 2066 904 2744 1029
PEDROLLO 6” motor
3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"
Ø DN
h1
INLET DN
DIMENSIONS AND WEIGHTS
-B-
versionswith6"motors TYPE Three-phase 6 SR 9/9 - PD 6 SR 9/12 - PD 6 SR 9/17 - PD 6 SR 9/21 - PD 6 SR 9/24 - PD 6 SR 12/8 - PD 6 SR 12/11 - PD 6 SR 12/15 - PD 6 SR 12/18 - PD 6 SR 12/21 - PD 6 SR 12/25 - PD 6 SR 12/28 - PD 6 SR 18/4 - PD 6 SR 18/6 - PD 6 SR 18/9 - PD 6 SR 18/11 - PD 6 SR 18/13 - PD 6 SR 18/15 - PD 6 SR 18/18 - PD 6 SR 18/22 - PD 6 SR 18/26 - PD 6 SR 27/5 - PD 6 SR 27/7 - PD 6 SR 27/8 - PD 6 SR 27/10 - PD 6 SR 27/12 - PD 6 SR 27/14 - PD 6 SR 27/17 - PD 6 SR 27/20 - PD 6 SR 27/27 - PD 6 SR 36/4 - PD 6 SR 36/6 - PD 6 SR 36/8 - PD 6 SR 36/10 - PD 6 SR 36/11 - PD 6 SR 36/13 - PD 6 SR 36/15 - PD 6 SR 36/19 - PD 6 SR 36/23 - PD 6 SR 44/3 - PD 6 SR 44/4 - PD 6 SR 44/5 - PD 6 SR 44/6 - PD 6 SR 44/8 - PD 6 SR 44/9 - PD 6 SR 44/11 - PD 6 SR 44/13 - PD 6 SR 44/15 - PD 6 SR 44/21 - PD
31.3 34.8 42.4 49.3 56.4 30.3 33.8 41.5 48.3 54.7 37.3 43.2 49.0 43.0 47.6
h
3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"
Ø 137
h2
DN
DIMENSIONS mm h1 h2 571 454 658 560 745 660 875 745 1137 850 528 454 615 560 702 660 832 745 1051 850 528 660 615 745 746 850 619 745 725 850
PEDROLLO 4” motor
TYPE Three-phase 6 SR 9/5 LR -PD 6 SR 9/7 LR -PD 6 SR 9/9 LR -PD 6 SR 9/12 LR -PD 6 SR 9/17 LR -PD 6 SR 12/4 LR -PD 6 SR 12/6 LR -PD 6 SR 12/8 LR -PD 6 SR 12/11 LR -PD 6 SR 12/15 LR -PD 6 SR 18/4 LR -PD 6 SR 18/6 LR -PD 6 SR 18/9 LR -PD 6 SR 27/5 LR -PD 6 SR 27/7 LR -PD
4”
6”
-A-
-B-
6" submerged electropumps with FRANKLIN ELECTRIC® motors
-A-
versionswith4"motors INLET Ø 137
137
Ø
DN
DN
146.5
56.0 62.3 71.6 83.6 90.2 55.1 63.5 69.9 74.9 87.1 97.2 100.3 51.4 56.8 64.2 69.7 74.9 81.1 89.8 100.6 110.9 56.6 62.8 66.1 72.3 80.2 87.8 98.4 108.2 131.3 56.9 65.2 73.4 79.7 85.1 94.9 99.0 113.7 127.7 55.5 60.5 67.3 71.6 79.1 86.9 90.9 101.5 111.6 138.3
h1
kg h 1358 1521 1815 2020 2184 1314 1477 1728 1890 2053 2292 2422 1141 1260 1423 1541 1706 1858 1988 2227 2465 1264 1402 1487 1626 1842 1948 2171 2395 2895 1405 1664 1922 2180 2326 2617 2843 3360 3877 1292 1438 1583 1728 1987 2165 2391 2682 2973 3781
h
143.5
DIMENSIONS mm h1 h2 776 582 906 615 1168 647 1341 679 1472 712 732 582 862 615 1081 647 1211 679 1341 712 1515 777 1645 777 559 582 645 615 776 647 862 679 994 712 1081 777 1211 777 1385 842 1558 907 649 615 755 647 808 679 914 712 1065 777 1171 777 1329 842 1488 907 1858 1037 823 582 1049 615 1275 647 1501 679 1614 712 1840 777 2066 777 2518 842 2970 907 710 582 823 615 936 647 1049 679 1275 712 1388 777 1614 777 1840 842 2066 907 2744 1037
h2
Ø
FRANKLIN ELECTRIC 6” motor
3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"
Ø
h
INLET DN
DIMENSIONS AND WEIGHTS
-B-
versionswith6"motors TYPE Three-phase 6 SR 9/9 - FK 6 SR 9/12 - FK 6 SR 9/17 - FK 6 SR 9/21 - FK 6 SR 9/24 - FK 6 SR 12/8 - FK 6 SR 12/11 - FK 6 SR 12/15 - FK 6 SR 12/18 - FK 6 SR 12/21 - FK 6 SR 12/25 - FK 6 SR 12/28 - FK 6 SR 18/4 - FK 6 SR 18/6 - FK 6 SR 18/9 - FK 6 SR 18/11 - FK 6 SR 18/13 - FK 6 SR 18/15 - FK 6 SR 18/18 - FK 6 SR 18/22 - FK 6 SR 18/26 - FK 6 SR 27/5 - FK 6 SR 27/7 - FK 6 SR 27/8 - FK 6 SR 27/10 - FK 6 SR 27/12 - FK 6 SR 27/14 - FK 6 SR 27/17 - FK 6 SR 27/20 - FK 6 SR 27/27 - FK 6 SR 36/4 - FK 6 SR 36/6 - FK 6 SR 36/8 - FK 6 SR 36/10 - FK 6 SR 36/11 - FK 6 SR 36/13 - FK 6 SR 36/15 - FK 6 SR 36/19 - FK 6 SR 36/23 - FK 6 SR 44/3 - FK 6 SR 44/4 - FK 6 SR 44/5 - FK 6 SR 44/6 - FK 6 SR 44/8 - FK 6 SR 44/9 - FK 6 SR 44/11 - FK 6 SR 44/13 - FK 6 SR 44/15 - FK 6 SR 44/21 - FK
26.6 31.4 38.8 47.0 59.4 25.7 30.5 37.9 46.1 57.7 34.3 41.6 52.0 41.4 50.6
h1
3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"
kg h 927 1081 132 1573 1911 884 1038 1286 1530 1825 1112 1313 1520 1317 1499
h2
DN
DIMENSIONS mm h1 h2 571 356 658 423 745 584 875 698 1137 774 528 356 615 423 702 584 832 698 1051 774 528 584 615 698 746 774 619 698 725 774
FRANKLIN ELECTRIC 4” motor
TYPE Three-phase 6 SR 9/5 LR - FK 6 SR 9/7 LR - FK 6 SR 9/9 LR - FK 6 SR 9/12 LR - FK 6 SR 9/17 LR - FK 6 SR 12/4 LR - FK 6 SR 12/6 LR - FK 6 SR 12/8 LR - FK 6 SR 12/11 LR - FK 6 SR 12/15 LR - FK 6 SR 18/4 LR - FK 6 SR 18/6 LR - FK 6 SR 18/9 LR - FK 6 SR 27/5 LR - FK 6 SR 27/7 LR - FK
4”
6”
-A-
-B-
multi-impeller submersible electropumps forclearwater
RANGEOFPERFORMANCE Flow rate up to 100 l/min (6 m3/h) Head up to 42 m LIMITS OF USE Depth up to 10 m below the water level Liquid temperature up to + 40°C Maximum sand content 50 g/m3 Emptying level up to 30 mm from the bottom
CONSTRUCTIONCHARACTERISTICS ●
● ● ● ● ●
EXECUTIONANDSAFETYSTANDARDS
●
EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3
●
USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR PUMPING CLEAN WATER WITH A SAND CONTENT NO HIGHER THAN 50 g/m3. FOR THEIR HIGH YIELD AND RELIABILITY THEY ARE SUITABLE FOR SUPPLYING DOMESTIC WATER FROM TANKS, RESERVOIRS OR RELATIVELY DEEP WELLS, FOR DRAWING RAINWATER FROM CISTERNS FOR WATERING BY HAND OR FEEDING AN IRRIGATION SYSTEM, ETC. GUARANTEE 12YEAR GUARANTEE YEARSsubject accordingto to our general terms terms of sale. of sale. our general
DELIVERY BODY AND SUCTION GRID: technopolymer charged with glass fibre, particularly resistant to impact and corrosion, with threaded inlet ISO 228/1. IMPELLERS and DIFFUSORS: technopolymer. DIFFUSOR CONTAINER: stainless steel AISI 304. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: ceramic - carburundum- NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous single-phase for continuous duty. TOP MULTI: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. INSULATION: class F. ● PROTECTION: IP 68. REGISTERED MODEL n° 72765.
THE ELECTROPUMPS ARE COMPLETE WITH: TOP-MULTI
Float switch Neoprene power cable "H05 RN-F" length 10 metres with Schuko plug. “ Ring nut with hosetail. Coupling with flap valve.
EXECUTIONONREQUEST
⇒
other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
TOP-MULTI 3
TOP-MULTI 1
Head H
(metres)
TOP-MULTI 2
Flow rate Q
TYPE Single-phase TOP - MULTI 1 TOP - MULTI 2 TOP - MULTI 3
POWER kW
HP
0.37 0.55 0.55
Q
m3/h l/min
0.50 0.75 H metres 0.75
0
0.6
1.2
0
10
20
30
36 30 42
33 29 38
30.5 28 35
26.5 27 31
Q = Flow rate H = Total manometric head
1.8
2.4
3.0
3.6
4.2
4.8
5.4
6.0
40
50
60
70
80
90
100
21.5 26 25
14.5 24 17.5
5 22 8
19
15
10.5
5
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typical transportable application
e d
h1 h
p minimum
DN
a
TYPE Single-phase
minimum
INLET DN
N째 stages
a
h
DIMENSIONS mm h1 d
kg e
p
TOP - MULTI 1
11/4"
6
176
350
350
8.4
5
176
345 345 345
regolabile
11/4"
380 380 380
30
TOP - MULTI 2
30
adjustable
350
350
8.1
TOP - MULTI 3
11/4"
7
176
400
365
30
regolabile
350
350
8.9
DRAINAGE submersible electropumps for clear waters
These pumps, already famous for their design and safety of operation,aremadewithtechnologicallyinnovativematerials and have an excellent sturdy construction thanks to the stainless steel internal motor support.
RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 14.5 m
CONSTRUCTIONCHARACTERISTICS
LIMITS OF USE Depth up to 5 metres (3 metres up to 0.55 kW) Liquid temperature up to + 40°C (+90°C for a maximum period of 3 minutes) Passage of solid bodies up to Ø 10 mm Drainage level: up to 14 mm from the bottom for TOP 1-2-3 up to 30 mm from the bottom for TOP 4-5 EXECUTION AND SAFETY STANDARDS
●
EN 60 335-1 IEC 335-1 CEI 61-150
●
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS THE TOP SERIES IS SUITABLE FOR DRAINING CLEAR WATERS WITHOUT ABRASIVE PARTICLES. THE CONSTRUCTION SOLUTIONS USED GUARANTEE SIMPLICITY OF USE AND SAFE OPERATION THANKS TO THE TOTAL COOLING OF THE MOTOR AND THE DOUBLE MECHANICAL SEAL. THEY ARE RECOMMENDED FOR EMERGENCY DRYING OF SMALL FLOODED AREAS (ROOMS, CELLARS, GARAGES), FOR THE DISPOSAL OF WASTE WATER IN THE HOME (DISHWASHER, WASHING MACHINE), FOR EMPTYING DRAINAGE TRAPS. GUARANTEE GUARANTEE12YEAR YEARS according our general termsterms of sale. of sale. subject toto our general
●
● ● ● ●
●
●
DELIVERY BODY: technopolymer charged with glass fibre, particularly resistant to impact and corrosion, with threaded inlet ISO 228/1. SUCTION GRID: technopolymer. IMPELLER: open type in technopolymer. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: ceramic - graphite - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous single-phase for continuous duty. TOP: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding . INSULATION: class F. ● PROTECTION: IP 68. REGISTERED MODEL nº 72765.
THE ELECTROPUMPS ARE COMPLETE WITH: TOP 1-2-3
(single-phase ) Float switch. Ring nut with hosetail. Power cable in neoprene "H05 RN-F" length 5 metres with Schuko plug.
TOP 4-5
(single-phase ) Float switch. Ring nut with hosetail. ② Couplingwith flap valve. Neoprene power cable "H05 RN-F" length 10 metres with Schuko plug.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒ ⇒
electropumps for aggressive liquids TOP - LA special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
TOP5
TOP4
Head H (metres)
TOP3
TOP2
TOP1
Flow rate Q
TYPE Single-phase TOP 1 TOP 2 TOP 3 TOP 4 TOP 5
POWER
Q
m3/h
0
1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12 13.2 14.4 15.6 16.8 18.0 19.2 20.4 21.6 22.8 24
l/min
0
20 40
kW
HP
0.25 0.37 0.55 0.75 0.92
0.33 7 6 5.5 0.50 9 8 7.5 0.75 H 10.5 10 9 1 metres 12.6 12 11.5 14.5 14 13.5 1.25
60
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
4.5 3.5 2.5 2 1 6.5 6 5.5 4.5 4 3 2.5 1.8 1 8.8 8 7.5 6.5 6 5.5 4.8 4 3.5 2.5 2 10.7 10 9.3 8.7 8 7.3 6.7 6 5.3 4.7 4 3.3 2.7 2 12.7 12.1 11.5 10.8 10.2 9.6 8.9 8.3 7.7 7.1 6.4 5.8 5.2 4.5 3.9 3.3 2.6
Q = Flow rate H = Total manometric head
DIMENSIONSANDWEIGHTS
Typicalinstallation
DN
TOP-LA* for aggressive liquids
d
pumped liquid in stainless steel AISI 316.
e
h1 h
* Metal components in contact with the
p minimum
TYPE Single-phase TOP 1 - LA TOP 2 - LA TOP 3 - LA TOP 4 - LA TOP 5 - LA
minimum
a TYPE Single-phase TOP 1 TOP 2 TOP 3 TOP 4 TOP 5
2
Tolerance of the performance curves according to EN ISO 9906 App. A.
INLET DN
1" 1/4" 111/4 "
11/4" 11/2"
111/2 " 1/2"
a 152 152 152 204 204 204
h 232 257 287 334 334 334
h1 217 237 267 310 310 310
DIMENSIONS mm d e 14 14 adjustable 14 21 21 21
kg p 350 350 350 450 450 450
350 350 350 450 450 450
4.1 5.0 6.4 9.8 10.8
DRAINAGE submersible electropumps for clear waters
The particular constructive design of the TOP FLOOR pump guarantees drying up to a height of 2 mm above the floor.
RANGE OF PERFORMANCE Flow rate up to 220 l/min (13.2 m3/h) Head up to 9 m
CONSTRUCTIONCHARACTERISTICS
LIMITS OF USE Depth up to 3 m Liquid temperature up to +40°C (+90° C for a maximum period of 3 minutes) Passage of solid bodies up to Ø 5 mm Drainage level up to 2 mm from the bottom
●
●
● ● ● ●
●
EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
DELIVERY BODY: technopolymer charged with glass fibre, particularly resistant to impact and corrosion, with threaded inlet ISO 228/1. SUCTION GRID: technopolymer. IMPELLER: open type in technopolymer. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: ceramic - graphite - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous single-phase for continuous duty. TOP-FLOOR: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding . INSULATION: class F. ● PROTECTION: IP 68. REGISTERED MODEL nº 72765
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS THE TOP-FLOOR SERIES IS SUITABLE FOR DRAINING CLEAR WATERS WITHOUT ABRASIVE PARTICLES. THANKS TO THEIR ABILITY TO SUCK UP WATER AS FAR AS 2 MILLIMETRES FROM THE BOTTOM, THEY ARE INDICATED FOR EMERGENCY DOMESTIC USE FOR SMALL FLOODED AREAS AND IN ALL THOSE APPLICATIONS WHERE MAXIMUM DRYING LEVELS ARE REQUIRED. GUARANTEE 1 2YEAR subject totoour general GUARANTEE YEARS according our general termsterms of sale. of sale.
TOP-FLOOR
Neoprene power cable "H05 RN-F" length 5 metres with Schuko plug. Ring nut with hosetail.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
electropumps with external float switch special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
TOP2-FLOOR
Head H (metres)
TOP1-FLOOR
Flow rate Q
TYPE Single-phase TOP1 - FLOOR TOP2 - FLOOR
POWER kW
m3/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12.0
13.2
l/min
0
20
40
60
80
100
120
140
160
180
200
220
0.33 H metres 0.50
7 9
6 8
5.5 7.5
4.5 6.5
3.5 6
2.5 5.5
2 4.5
1 4
3
2.5
1.8
1
Q
HP
0.25 0.37
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typicalinstallation
Drying up to 2 mm
h
h1
DN
a
TYPE Single-phase TOP1 - FLOOR TOP2 - FLOOR
INLET DN
1" 11/4"
a 152 152 152
DIMENSIONS mm h 232
h1 217
Minimum drying level 2 mm
3.9
257
237
2 mm
4.9
2 mm
kg
VORTEX submersible electropumps fordirtywaters
Thanks to the well-tested VORTEX system, this submersible pump allows the evacuation of dirty waters containing suspended solid bodies without any risk of clogging the impeller.
RANGE OF PERFORMANCE Flow rate up to 180 l/min (10.8 m3/h) Head up to 7 m
CONSTRUCTIONCHARACTERISTICS
LIMITS OF USE Depth up to 3 m Liquid temperature up to + 40°C (+90° C for a maximum period of 3 minutes) Passage of solid bodies up to Ø 20 mm Drainage level up to 25 mm from the bottom
●
●
● ● ● ●
●
EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS THE TOP-VORTEX PUMP IS SUITABLE FOR DRAINING DIRTY WATERS THAT ARE CHEMICALLY NON AGGRESSIVE FOR THE MATERIALS OF WHICH THE PUMP IS MADE. THE CONSTRUCTIVE SOLUTIONS GUARANTEE SIMPLICITY OF USE AND SAFE OPERATION THANKS TO THE TOTAL COOLING OF THE MOTOR AND THE DOUBLE MECHANICAL SEAL. IT IS RECOMMENDED FOR DOMESTIC USE, FOR THE EVACUATION OF DIRTY WATERS, FOR EMPTYING TANKS, DOMESTIC DRAINS, EMPTYING COLLECTION TRAPS, EVEN IN THE PRESENCE OF SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 20 mm. GUARANTEE subject toto our general GUARANTEE12YEAR YEARS according our general termsterms of sale. of sale.
● ●
DELIVERY BODY: technopolymer charged with glass fibre, particularly resistant to impact and corrosion, with threaded inlet ISO 228/1. SUCTION GRID: technopolymer. IMPELLER: technopolymer. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: ceramic - graphite - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous single-phase for continuous duty. TOP-VORTEX: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding . INSULATION: class F. ● PROTECTION: IP 68. REGISTERED MODEL nº 72765
THE ELECTROPUMPS ARE COMPLETE WITH: TOP-VORTEX
Float switch. Ring nut with hosetail. Neoprene power cable "H05 RN-F" length 5 metres with Schuko plug.
EXECUTIONS ON REQUEST
⇒ ⇒
special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Head H (metres)
TOP-VORTEX
Flow rate Q
TYPE Single-phase TOP - VORTEX
POWER kW
m3/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
l/min
0
20
40
60
80
100
120
140
160
180
0.50 H metres
7
6.5
6
5.4
4.8
4.2
3.5
3
2.5
1.5
HP
0.37
Q
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typicalinstallation
d
a
e
p minimum
h
h1
DN
TYPE Single-phase
INLET DN
a
h
h1
DIMENSIONS mm d
TOP - VORTEX
11/4"
152
288
268
25
minimum
kg e
p
adjustable
350
350
5.0
DRAINAGE submersible electropumps for clear waters
Sturdy high-quality submersible pumps in stainless steel, for drainage of clear waters. Recommended for fixed installations or for draining domestic waters or rainwater and for emptying tanks or reservoirs.
RANGEOFPERFORMANCE Flow rate up to 300 l/min (18 m3/h) Head up to 23 m LIMITS OF USE Depth up to 10 m Liquid temperature up to + 50°C Liquid temperature up to + 60°C for intermittent duty. Liquid temperature up to + 90°C for intermittent duty maximum 3 minutes.
Passage of solid bodies up to Ø 10 mm Drainage level: up to 14 mm from the bottom for RX 1-2 up to 30 mm from the bottom for RX 3-4-5
GUARANTEE 1 2 YEAR subject to toour terms of sale. GUARANTEE YEARS according our general general terms of sale.
CONSTRUCTIONCHARACTERISTICS ● ● ● ● ● ●
●
EXECUTIONANDSAFETYSTANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS RX PUMPS ARE SUITABLE FOR DRAINING CLEAR WATERS WITHOUT ABRASIVE PARTICLES. THE CONSTRUCTIVE SOLUTIONS EMPLOYED GUARANTEE SIMPLICITY OF USE AND SAFE OPERATION THANKS TO THE TOTAL COOLING OF THE MOTOR AND OF THE DOUBLE MECHANICAL SEAL. THEY ARE RECOMMENDED FOR FIXED INSTALLATIONS, EMERGENCY DRYING OF SMALL FLOODED AREAS (BASEMENT ROOMS, CELLARS, GARAGES), FOR DISPOSAL OF DIRTY WATER USED IN THE HOME BY WASHING MACHINES AND DISHWASHERS, FOR DRAINING COLLECTION TRAPS.
● ●
DELIVERY BODY: stainless steel AISI 304, with threaded inlet ISO 228/1. SUCTION GRID: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: ceramic - graphite - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous single-phase for continuous duty. RXm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. RX: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68. REGISTERED MODEL.
THE ELECTROPUMPS ARE COMPLETE WITH: R Xm
(single-phase ) float switch. Neoprene power cable "H05 RN-F" length 5 metres with Schuko plug.
RX
(three-phase ) Neoprene power cable "H05 RN-F" length 5 metres .
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒ ⇒
special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
RX5
Head H
(metres)
RX4
RX3
RX2
RX1
Flow rate Q
TYPE Single-phase RXm 1 RXm 2 RXm 3 RXm 4 RXm 5
Three-phase RX 2 RX 3 RX 4 RX 5
POWER kW
Q
HP
0.25 0.37 0.55 0.75 1.1
m3/h
0
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8 12.0 13.2 14.4 15.6 16.8 18.0
l/min
0
20
40
60
80
100
120
140
160
180
7.5 10 17 20 23
6.5 9.5 16 19 22
5.8 5 8.8 8 15 13.8 18 16.8 21 20
0.33 0.50 0.75 H metres 1 1.5
4.3 3.5 7.3 6.5 12.8 11.7 15.8 14.7 18.8 17.7
Q = Flow rate H = Total manometric head
2.8 2 5.8 5 4.3 10.5 9.5 8.5 13.5 12.5 11.5 16.5 15.5 14.5
200
220
240
260
280
300
3 6 9
5 8
7
3.5 2.8 2 7.3 6.3 5.2 4 10.5 9.3 8.2 7.2 13.5 12.4 11.3 10.2
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typical single-phase installation
e
p minimum
h
h1
DN
TYPE Single-phase Three-phase RXm 1 ––– RXm 2 RX 2 RXm 3 RX 3 RXm 4 RX 4 RXm 5 RX 5
d
a
INLET DN 1/4" 111/4 "
11/4"
11/4" 111/2 " 1/4" 11/4"
a 147 147 147 215 215 215
h 255 255 255 355 355 355
h1 247 247 247 336 336 336
DIMENSIONS mm d e 17 regolabile 17 17 regolabile 30 regolabile adjustable 30 regolabile 30 regolabile
minimum
kg p 350 350 350 500 500 500
350 350 350 500 500 500
1~ 4.7 5.7 12.0 13.0 14.0
3~ 5.5 10.7 11.7 12.7
VORTEX submersible electropump for dirty waters
VORTEX sturdy high-quality submersible pumps in stainless steel. Thanks to the well-tested VORTEX system it allows the evacuation of dirty waters containing suspended solid bodies.
RANGEOFPERFORMANCE Flow rate up to 450 l/min (27 m3/h) Head up to 14.5 m
CONSTRUCTIONCHARACTERISTICS
LIMITS OF USE Depth up to 10 m Liquid temperature up to + 50°C
●
Liquid temperature up to + 60°C for intermittent duty. Liquid temperature up to + 90°C for intermittent duty maximum 3 minutes.
●
Passage of solid bodies: up to 20 mm for RX2 - up to 40 mm for RX3-4-5 Drainage level from the bottom: up to 25 mm for RX2 - up to 40 mm forRX3-4-5 EXECUTIONANDSAFETYSTANDARDS
● ● ● ●
●
● ●
EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
DELIVERY BODY: stainless steel AISI 304, with threaded inlet ISO 228/1. SUCTION GRID: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SUPPORT: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carborundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous single-phase for continuous duty. RXm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. RX: three-phase380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68. REGISTERED MODEL.
THE ELECTROPUMPS ARE COMPLETE WITH: RX m (single-phase) float switch. Xm Neoprene power cable "H05 RN-F" length 5 metres with Schuko plug.
USESANDINSTALLATIONS RX-VORTEX PUMPS ARE SUITABLE FOR DRAINING DIRTY WATERS. THE CONSTRUCTIVE SOLUTIONS GUARANTEE SAFE OPERATION, EVEN IN THE CASE OF CONTINUOUS USE, THANKS TO THE TOTAL COOLING OF THE MOTOR BY THE PUMPED LIQUID. THEY ARE RECOMMENDED FOR DOMESTIC USE, FOR DRAINING DIRTY WATER CONTAINING SUSPENDED SOLID BODIES.
GUARANTEE12YEAR YEARS accordingto to our general termsterms of sale. of sale. GUARANTEE subject our general
RX
(three-phase) Neoprene power cable "H05 RN-F" length 5 metres .
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒ ⇒
special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Head H
(metres)
RX5/40
RX4/40
RX3/40
RX2/20
Flow rate Q
TYPE Single-phase RXm 2/20 RXm 3/40 RXm 4/40 RXm 5/40
Three-phase RX 2/20 RX 3/40 RX 4/40 RX 5/40
POWER
m3/h
0
1.2
2.4
l/min
0
20
40
60
0.50 7 6.5 0.75 H metres 9 8.5 1 11 10.5 15 14.5 1.5
6 8 10 14
5.4 7.4 9.4 13.3
kW
Q
HP
0.37 0.55 0.75 1.1
Q = Flow rate H = Total manometric head
3.6
4.8 80
6
7.2
8.4
9.6 10.8
12
15
100 120 140
160 180
200 250
18
19.5
21
300 325 350
24
27
400 450
4.8 4.3 3.7 3.1 2.5 2 6.8 6.3 5.7 5.1 4.5 4 3.4 2 8.8 8.3 7.7 7.1 6.6 6 5.5 4 2.7 2 12.8 12.2 11.6 11 10.4 9.8 9.2 7.8 6.3 5.6 4.9 3.5 2 Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typical single-phase installation
a
TYPE Single-phase Three-phase RXm 2/20 RX 2/20 RXm 3/40 RX 3/40 RXm 4/40 RX 4/40 RXm 5/40 RX 5/40
minimum
INLET DN
11/4" 11/2"
11/2" 11/2"
e d
p minimum
h1 h
DN
a 147 215 215 215
h 286 405 405 405
h1 278 386 386 386
DIMENSIONS mm d e 25 regolabile 40 regolabile adjustable 40 regolabile 40 regolabile
kg p 350 500 500 500
350 500 500 500
1~ 5.9 12.4 13.4 14.4
3~ 5.7 11.1 12.1 13.1
DRAINAGE submersible electropumps for clear waters
Submersible pumps for domestic use, economic, compact, reliable. Recommended for draining clear or slightly dirty waters.
RANGE OF PERFORMANCE Flow rate up to 300 l/min (18 m3/h) Head up to 14 m LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 10 mm Drainage level up to 15 mm from the bottom For continuous duty: minimum immersion 180 mm EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
GUARANTEE YEARS accordingto to our termsterms of sale. of sale. GUARANTEE 12YEAR subject ourgeneral general CONSTRUCTIONCHARACTERISTICS ● ● ● ● ● ● ●
●
THE ELECTROPUMPS ARE COMPLETE WITH: ZD m Float switch. Dm Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
USESANDINSTALLATIONS DESIGNED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATERS, THEY ARE SUITABLE FOR DOMESTIC USE FOR DRAINING FLOODED AREAS SUCH AS CELLARS AND FOR EMPTYING TANKS AND RESERVOIRS; THEY ARE OUTSTANDING FOR THEIR SIMPLICITY OF INSTALLATION AND THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.
DELIVERY BODY: cast iron, with threaded inlet ISO 228/1. MOTOR CASING: stainless steel AISI 304. SUCTION GRID: stainless steel AISI 304. IMPELLER: open, in technopolymer. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. MOTOR: submersible asynchronous single-phase for continuous duty. ZDm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. INSULATION: class F. ● PROTECTION: IP 68.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 10
0
20
30
10
0
40
20
50
30
60
40
70
50
US g.p.m. 60
Imp. g.p.m. feet
15 14
45
ZD1AR-E
13 40
12
Head H (metesi)
11
35
ZD1A-E
10 30
9 ZD1B-E
8
25
7 20
6 5
15
4 10
3 2
5
1 0
0
25
50
75
100
0
125
150
5
TYPE
kW
225
250
10
Q
HP
0.37 0.50 0.60
200
275
300
l/min m3 /h
15
Flow rate Q
POWER
Single-phase ZDm 1B-E ZDm 1A-E ZDm 1AR-E
175
m3/h
0
1.5
3.0
4.5
6.0
7.5
9.0
10.5
12.0
13.5
15.0
16.5
18.0
l/min
0
25
50
75
100
125
150
175
200
225
250
275
300
8.5 11 14
8 10.5 13.5
7.5 10 13
6.5 9 12.2
5.5 8.5 11.5
4.8 7.5 10.5
3.5 6.5 9.5
2.5 5.5 8.3
1 4 7
2.5 5.7
1.5 4.5
3.2
2
0.50 0.70 H metres 0.85
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typicalinstallation
h
p minimo
a
d
h1
DN
e
0
TYPE Single-phase ZDm 1B-E ZDm 1A-E ZDm 1AR-E
INLET DN
11/2"
11/2" 11/2"
minimum
c
b
a 105 110 105
b 81 81 81
c 136 142 136
DIMENSIONS mm h h1 d 258 66 15 310 258 66 15 273 66 15
kg e regolabile regolabile adjustable regolabile
p 450 450 450
450 450 450
9.8 10.4 11.3
VORTEX submersible electropumps for very dirty waters
VORTEX submersible pumps, economic, compact, reliable, recommended for domestic use. Thanks to the well-tested VORTEX system it allows the evacuation of dirty waters containing suspended solid bodies.
RANGE OF PERFORMANCE Flow rate up to 300 l/min (18 m3/h) Head up to 10 m LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 40 mm Drainage level up to 40 mm from the bottom For continuous duty: minimum immersion 240 mm EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
GUARANTEE YEARS according our general termsterms of sale. of sale. GUARANTEE 12 YEAR subject totoour general CONSTRUCTIONCHARACTERISTICS ● ● ● ● ● ●
●
DELIVERY BODY: cast iron, with threaded inlet ISO 228/1. MOTOR JACKET: stainless steel AISI 304. IMPELLER: open, in technopolymer charged with glass fibre. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. MOTOR: submersible asynchronous single-phase for continuous duty. ZXm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: ZX m Float switch. Xm Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
USESANDINSTALLATIONS
EXECUTIONS ON REQUEST
ZX PUMPS ARE RECOMMENDED FOR DRAINING SOLID-LADEN WASTE WATER IN THE DOMESTIC SECTOR, FOR THE EVACUATION OF DIRTY WATER, EVEN IN THE PRESENCE OF SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 40 mm. THEY ARE OUTSTANDING FOR THEIR SIMPLICITY OF INSTALLATION AND THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.
⇒ ⇒ ⇒ ⇒
special mechanical seal electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
ZX1A
Head H (metres)
ZX1B
Flow rate Q
TYPE
POWER
Single-phase ZXm 1B/40 ZXm 1A/40
kW
HP
0.50 0.60
Q
m3/h
0
1.5
3.0
4.5
6.0
9.0
12.0
15.0
18.0
21.0
24.0
l/min
0
25
50
75
100
150
200
250
300
350
400
9 11
8.5 10.5
8.3 10
8 9.5
7.5 9.2
6.5 8.2
5.2 7
4 5.7
2.5 4.3
1 2.8
1.5
0.70 H metres 0.85
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
a
h
Typicalinstallation
c
b
TYPE Single-phase ZXm 1B/40 ZXm 1A/40
DN
passage of solid bodies
11/2" 11/2"
Ø Ø 35 40 mm mm Ø 35 mm
INLET
11/2"
e d
h1
p minimum
DN
a 105 110 105
b 86 93 86
c 136 150 136
DIMENSIONS mm h h1 d 372 120 40 40 372 128 325 120 40
minimum
kg e regolabile adjustable regolabile
p 450 450 450
450 450 450
10.8 12.4
DRAINAGE submersible electropumps for clear or slightly dirty waters
DRAINAGE submersible pumps for professional use, with generous dimensions, particularly reliable.
RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 27 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 10 mm Drainage level up to 15 mm from the bottom For continuous duty: minimum immersion 220 mm EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ● ●
●
●
THE ELECTROPUMPS ARE COMPLETE WITH: Dm
(single-phase) Float switch. Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
D
(three-phase) Neoprene power cable "H07 RN-F" length 5 metres.
USESANDINSTALLATIONS DESIGNED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATERS, THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL AND PROFESSIONAL USE, FOR DRAINING FLOODED AREAS SUCH AS CELLARS, GARAGES OR FOR EMPTYING SWIMMING POOLS OR TANKS, FOR DISPOSING OF NON-SEWAGE WASTE WATERS. THESE PUMPS ARE OUTSTANDING FOR THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.
GUARANTEE YEARS accordingto to our general terms terms of sale. of sale. GUARANTEE 12YEAR subject our general
DELIVERY BODY: cast iron, with threaded inlet ISO 228/1. MOTOR JACKET: stainless steel AISI 304. SUCTION GRID: stainless steel AISI 304. IMPELLER: open, in technopolymer charged with glass fibre. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. Dm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. D: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒
electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
D30
D20
Head H (metres)
D15 D18 D10
D8
D6
Flow rate Q
TYPE Single-phase Dm 6 Dm 8 Dm 10 Dm 15 Dm 18 Dm 20 Dm 30
POWER
Three-phase ––– ––– D 10 D 15 ––– D 20 D 30
kW
HP
0.45 0.60 0.75 1.1 0.6 0.75 1.1
Q
m3/h
0
1.5
3.0
4.5
6.0
7.5
9.0
10.5 12.0
13.5 15.0 16.5 18.0
19.5 21.0 24.0
l/min
0
25
50
75
100
125
150
175 200
225
0.60 0.85 1 H metres 1.5 0.85 1 1.5
9 8.5 8 12 11.5 11 15 14.5 14 19.5 19 18.5 17 16.5 15 21 20 19 27 26 25
Q = Flow rate H = Total manometric head
7.5 6.8 6 10.5 9.8 9 13.2 12.5 11.8 18 17.5 16.5 13.5 12 10.7 17.5 16 15 23.5 22 21
5.2 4 8.2 7.2 11 10 16 15 9 7.7 13.5 12 19.5 18
2.6 1 6 4.8 9 8 14 13 5 10 16 14.5
250
275
300
325
350
400
3.5 2 6.8 5.4 11.8 10.5
3.5 9.2
2 8
7
4
13
11.5
10
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typical single-phase installation
b
TYPE Single-phase Three-phase Dm 6 ––– Dm 8 ––– Dm 10 D 10 Dm 15 D 15 Dm 18 ––– Dm 20 D 20 Dm 30 D 30
d
h1
DN
e
h
p minimo
a
c
INLET DN
11/2" 11/2" 11/2" 111/2 " 1/2" 11/2" 11/2" 11/2"
a 105 105 105 110 105 105 105 110
b 81 81 81 90 81 81 81 90
c 136 136 136 140 136 136 136 140
DIMENSIONS mm h h1 d 320 66 15 320 66 15 320 66 15 15 340 80 320 66 15 320 66 320 66 15 340 80 15
minimum
kg e regolabile regolabile regolabile adjustable regolabile regolabile regolabile regolabile
p 500 500 500 500 500 500 500
500 500 500 500 500 500 500 500
1~ 10.6 11.9 13.0 15.2 12.0 13.0 15.2
3~ 11.9 14.1 11.9 14.1
VORTEX submersible electropumps forsewagewaters
VORTEX submersible pumps for professional use, with generousdimensions,particularlyreliable.Thanks to the welltested VORTEX system it allows the evacuation of dirty waters containing suspended solid bodies.
RANGE OF PERFORMANCE Flow rate up to 500 l/min (30 m3/h) Head up to 15 m LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 50 mm For continuous duty: minimum immersion 290 mm
CONSTRUCTIONCHARACTERISTICS ● ● ● ● ● ●
●
EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
●
DELIVERY BODY: cast iron, with threaded inlet ISO 228/1. MOTOR JACKET: stainless steel AISI 304. BASE: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. VXm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. VX: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR DOMESTIC, CIVIL AND INDUSTRIAL USE, IN ALL CASES IN WHICH THE WATERS CONTAIN SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 50 mm, FOR EXAMPLE WATER MIXED WITH MUD, GROUNDWATER, SURFACE WATER, SOLID-LADEN WATER AND SEWAGE. THEIR USE IS RECOMMENDED FOR DRYING FLOODED AREAS SUCH AS CELLARS, UNDERGROUND CAR PARKS, CAR WASHING AREAS, FOR DOMESTIC DRAINS, FOR EMPTYING CESSPITS, SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING FOR THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION. GUARANTEE 12YEAR subject our general GUARANTEE YEARS accordingto to our general terms terms of sale. of sale.
VX m (single-phase) Float switch. Xm Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
VX
(three-phase) Neoprene power cable "H07 RN-F" length 5 metres.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒
electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
Head H (metres)
VX15/35
VX15/50 VX10/35
VX8/35 VX10/50 VX8/50
Flow rate Q
TYPE Single-phase VXm 8/35 VXm 10/35 VXm 15/35 VXm 8/50 VXm 10/50 VXm 15/50
POWER
Three-phase ––– VX 10/35 VX 15/35 ––– VX 10/50 VX 15/50
kW
HP
0.60 0.75 1.1 0.60 0.75 1.1
Q
m3/h
0
3
6
9
12
15
18
21
24
27
30
l/min
0
50
100
150
200
250
300
350
400
450
500
8.4 10
7.5 9.5
6.5 8.5
5.2 7.2
3.7 5.8
2 4
2
15
14
13
11.8
10.5
9
7.5
6
4
2
6
5.5
5
4.4
3.6
2.8
2
1
7.5
7
6.5
5.8
5
4
3.2
2.4
1.5
11
10.5
10
9.5
9
8.3
7.5
6.8
6
0.85 1 1.5 H metres 0.85 1 1.5
Q = Flow rate H = Total manometric head
5
4
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typicalsingle-phaseinstallation
h1
DN
e
p minimum
h
a
TYPE Single-phase Three-phase VXm 8/35 ––– VXm 10/35 VX 10/35 VXm 15/35 VX 15/35 VXm 8/50 ––– VXm 10/50 VX 10/50 VXm 15/50 VX 15/50
c
DN
passage of solid bodies
11/2" 1/2" 111/2 " 11/2" 2" 2" 2" 2"
Ø 35 mm Ø 35 mm Ø 35 mm Ø 50 mm Ø 50 mm Ø 50 mm
INLET
d
b
a 105 105 105 110 110 110 120
b 87 87 87 92 90 90 90 97
c 137 137 137 143 150 150 150 163
DIMENSIONS mm h h1 380 123 380 123 380 123 400 133 410 153 410 153 410 153 430 158
minimum
kg d 40 40 40 55 55 55 55 65
e regolabile regolabile regolabile adjustable regolabile regolabile regolabile
p 500 500 500 500 500 500 500
500 500 500 500 500 500 500
1~ 12.4 13.5 15.7 13.4 13.9 16.1
3~ 12.1 14.6 12.1 15.0
TWO-CHANNEL submersible electropumps forsewagewaters
TWO-CHANNEL submersible pumps for professional use, withgenerousdimensions,particularlyreliable;characterised by high yield.
RANGE OF PERFORMANCE Flow rate up to 800 l/min (48 m3/h) Head up to 15 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 50 mm For continuous duty: minimum immersion 290 mm EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ● ●
●
●
DELIVERY BODY: cast iron, with threaded inlet ISO 228/1. MOTOR JACKET: stainless steel AISI 304. BASE: stainless steel AISI 304. IMPELLER: two-channel, in stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. MCm: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. MC: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS MC SUBMERSIBLE PUMPS ARE RECOMMENDED FOR DRAINING DIRTY WATER AND SEWAGE IN THE DOMESTIC AND CIVIL SECTORS. THEY ARE EQUIPPED WITH A “TWO-CHANNEL" STAINLESS STEEL IMPELLER WHICH ALLOWS THE PUMPING OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 50 mm, WITH SHORT FIBRE. THEY ARE INDICATED FOR CONVEYING DRAINAGE WATERS AND SEWAGE, WASTE WATERS, SURFACE WATERS, WATERS MIXED WITH MUD IN USES SUCH AS: HOLIDAY HOMES, BUNGALOWS AND SINGLEFAMILY HOMES. THESE PUMPS ARE OUTSTANDING FOR THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION. subject our general GUARANTEE 12YEAR GUARANTEE YEARS accordingto to our general termsterms of sale. of sale.
MC m (single-phase) Float switch. Cm Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
MC
(three-phase) Neoprene power cable "H07 RN-F" length 5 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
20
0
40
60
20
80
40
100
60
120
80
140
100
160
120
180
200
140
220
160
180
16
feet 50
14
MC12/50 45
40
12
Head H (metres)
MC10/50
35
10 30
8
25
6
20
15
4 10
2 5
0
0
100
0
200
0
300
10
TYPE Monofase MCm 10/50 MCm 12/50
20
POWER
Trifase MC 10/50 MC 12/50
400
Q
0
m3/h
kW
HP
0.75 1.1
1 H metres 1.5
l/min
500
Flow rate Q
600
700
30
800
40
50
3
6
9
12
15
18
21
24
27
30
36
42
48
0
50
100
150
200
250
300
350
400
450
500
600
700
800
12 15
10.7 14
9.7 13
8.7 12.3
7.8 11.5
6.8 10.5
5.9 9.7
5 8.8
4 8
3 7
2 6.2
4.5
2.7
1
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typicalsingle-phaseinstallation
h1
DN
e
p minimum
h
a
TYPE Single-phase Three-phase MCm 10/50 MC 10/50 MCm 12/50 MC 12/50
c
DN
passage of solid bodies
2" 2" 2"
Ø 50 mm Ø 50 mm Ø 50 mm
INLET
d
b
a 110 120
b 90 97
c 150 163
DIMENSIONS mm h h1 d 410 153 55 430 158 65
minimum
kg e regolabile adjustable regolabile
p 500 500 500
500 500 500
1~ 14.3 16.5
3~ 13.3 14.3
VORTEX submersible electropumps forsewagewaters
VORTEX submersible pumps made completely of stainless steel, for professional use, with generous dimensions, particularlyreliable. Thanks to the well-tested vortex system it allows the evacuation of dirty waters containing suspended solid bodies.
RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 10 m LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 50 mm For continuous duty: minimum immersion 280 mm EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
CONSTRUCTIONCHARACTERISTICS ● ● ● ● ●
●
●
DELIVERY BODY: stainless steel AISI 304, with threaded inlet ISO 228/1. MOTOR JACKET AND BASE: stainless steel AISI 304. IMPELLER: stainless steel AISI 304. MOTOR SHAFT: stainless steel AISI 316. DOUBLE MECHANICAL SEAL: carburundum - NBR - stainless steel AISI 316 pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. VXm-I: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. VX-I: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS THEY ARE RECOMMENDED FOR DRAINING SOLID-LADEN WASTE WATER IN THE DOMESTIC , CIVIL AND INDUSTRIAL SECTOR, IN ALL CASES WHERE THE WATERS CONTAIN SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 50 mm, FOR EXAMPLE WATERS MIXED WITH MUD, GROUNDWATER, SURFACE WATERS. THEIR USE IS RECOMMENDED FOR DRYING FLOODED AREAS SUCH AS CELLARS, UNDERGROUND CAR PARKS, CAR WASHING AREAS, FOR EMPTYING CESSPITS, SEWAGE DISPOSAL. THESE PUMPS ARE OUTSTANDING FOR THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION. GUARANTEE 12YEAR our general GUARANTEE YEARSsubject accordingto to our general terms terms of sale. of sale.
VX m-I Xm-I
(single-phase) Flow switch. Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
VX-I
(three-phase) Neoprene power cable "H07 RN-F" length 5 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
VX10/35-I
Head H (metres)
VX8/35-I VX10/50-I
VX8/50-I
Flow rate Q
TYPE Single-phase VXm 8/35-I VXm 10/35-I VXm 8/50-I VXm 10/50-I
POWER
Three-phase ––– VX 10/35-I ––– VX 10/50-I
kW
HP
0.60 0.75 0.60 0.75
0
m3/h
Q
l/min
0.85 1 H metres 0.85 1
3
6
9
12
15
18
21
24
0
50
100
150
200
250
300
350
400
8.4 10 6 7.5
7.5 9.5 5.5 7
6.5 8.5 5 6.5
5.2 7.2 4.4 5.8
3.7 5.8 3.6 5
2 4 2.8 4
2 2 3.2
1 2.4
1.5
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
a
e
h1
DN
p minimum
h
Typicalsingle-phaseinstallation
TYPE Single-phase Three-phase VXm 8/35-I ––– VXm 10/35-I VX 10/35-I VXm 8/50-I ––– VXm 10/50-I VX 10/50-I
DN
passage of solid bodies
11/2" 11/2" 2" 2" 2"
Ø 35 mm Ø 35 mm Ø 35 mm Ø Ø 50 50 mm mm Ø 50 mm
INLET
11/2"
d
b
a 108 108 108 118 118 118
b 166 166 166 166 166
DIMENSIONS mm h h1 d 380 87 40 380 87 40 380 87 40 410 108 55 410 108 55 410 108 55
minimum
kg e regolabile regolabile adjustable regolabile regolabile
p 500 500 500 500 500
500 500 500 500 500
1~ 9.7 9.6 12.8 10.7
3~ 9.3 9.7
TWO-CHANNEL submersible electropumps forsewagewaters
TWO-CHANNEL submersible pumps, in stainless steel, for professional use, with generous dimensions, particularly reliable; characterised by high yield.
RANGE OF PERFORMANCE Flow rate up to 800 l/min (48 m3/h) Head up to 15 m LIMITS OF USE Depth of use up to 5 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 50 mm For continuous duty: minimum immersion 280 mm EXECUTION AND SAFETY STANDARDS EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
CONSTRUCTIONCHARACTERISTICS ● ● ● ● ●
●
●
DELIVERY BODY: stainless steel AISI 304, with threaded inlet ISO 228/1. MOTOR JACKET AND BASE: stainless steel AISI 304. IMPELLER: two-channel, in stainless steel AISI 304. MOTOR SHAFT: stainless steel AISI 316. DOUBLE MECHANICAL SEAL: carburundum - NBR - stainless steel AISI 316 pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. MCm-I: single-phase 220÷240 V - 50 Hz with condenser and thermal overload protector built into the winding. MC-I: three-phase 380÷415V - 50 Hz. INSULATCION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS MC-I SUBMERSIBLE PUMPS ARE RECOMMENDED FOR DRAINING DIRTY WATER AND SEWAGE IN THE DOMESTIC AND CIVIL SECTORS. THEY ARE EQUIPPED WITH A “TWO-CHANNEL" IMPELLER WHICH ALLOWS THE PUMPING OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 50 mm WITH SHORT FIBRE. THEY ARE INDICATED FOR CONVEYING DRAINAGE WATERS AND SEWAGE, WASTE WATERS, SURFACE WATERS, WATERS MIXED WITH MUD IN USES SUCH AS: HOLIDAY HOMES, BUNGALOWS AND SINGLE-FAMILY HOMES. THESE PUMPS ARE OUTSTANDING FOR THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION.
GUARANTEE subject to general GUARANTEE12YEAR YEARS according to our our general termsterms of sale. of sale.
MC m-I (single-phase) Float switch. MCm-I Neoprene power cable "H07 RN-F" length 5 metres with Schuko plug.
MC-I
(three-phase) Neoprene power cable "H07 RN-F" length 5 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
electropumps with 10 metre power cable. N.B. obligatory for outdoor use according to standard EN 60335-2-41 electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
20
0
40
60
20
40
80
100
60
120
80
140
100
160
120
180
200
140
160
220 180
16
feet 50
MC15/50-I
14
45
40
12
Head H (metres)
MC10/50-I
35
10 30
8
25
6
20
15
4 10
2 5
0
0
100
0
200
0
300
400
10
20
TYPE Single-phase MCm 10/50-I –––
POWER
Three-phase MC 10/50-I MC 15/50-I
0
m3/h
Q
kW
HP
0.75 1.1
1 H metres 1.5
l/min
500
600
700
30
800
40
Flow rate Q
50
3
6
9
12
15
18
21
24
27
30
36
42
48
0
50
100
150
200
250
300
350
400
450
500
600
700
800
12 15
10.7 14
9.7 13
8.7 12.3
7.8 11.5
6.8 10.5
5.9 9.7
5 8.8
4 8
3 7
2 6.2
4.5
2.7
1
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
a
e
h1
DN
p minimum
h
Typicalsingle-phaseinstallation
TYPE Single-phase Three-phase MCm 10/50-I MC 10/50-I ––– MC 15/50-I
DN
passage of solid bodies
2" 2" 2"
ØØ50 50mm mm Ø 50 mm
INLET
d
b
a 118 118 118
b 166 166 166
DIMENSIONS mm h h1 d 410 109 55 55 109 410 410 109 55
minimum
kg e regolabile adjustable regolabile
p 500 500 500
500 500 500
1~ 12.8 -
3~ 9.8 12.8
DRAINAGE submersible electropumps for clear or slightly dirty waters
DRAINAGE submersible pumps in cast iron, particularly robust and reliable. Indicated in fixed installations
RANGE OF PERFORMANCE Flow rate up to 400 l/min (24 m3/h) Head up to 27 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 10 mm Drainage level up to 15 mm from the bottom For continuous duty: minimum immersion 210 mm
● ● ●
●
EXECUTION AND SAFETY STANDARDS EN EN 60034-1 60 335-1 IEC IEC 34-1 335-1 CEI CEI 2-3 61-150
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS DC SUBMERSIBLE PUMPS, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONGLASTING, ARE RECOMMENDED FOR DRAINING CLEAR OR SLIGHTLY DIRTY WATERS, FOR DISPOSING OF NON-SEWAGE WASTE WATERS ; THEY ARE OUTSTANDING FOR THEIR STURDINESS AND THEIR RELIABILITY IN FIXED INSTALLATIONS WITH AUTOMATIC OPERATION .
GUARANTEE YEARS accordingto to our general terms terms of sale. of sale. GUARANTEE 12YEAR subject our general
●
PUMP BODY: cast iron, with threaded inlet ISO 228/1. MOTOR CASING: cast iron. SUCTION GRID: stainless steel AISI 304. IMPELLER: cast iron. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. DCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding . DC: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: DC m Cm
(single-phase) Float switch. Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. Electric panel with condenser.
DC
(three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
DC30
DC20
Head H (metres)
DC15 DC18 DC10
DC8
DC6
Flow rate Q
TYPE Single-phase DCm 6 DCm 8 DCm 10 DCm 15 DCm 18 DCm 20 DCm 30
POWER
Three-phase ––– ––– DC 10 DC 15 ––– DC 20 DC 30
kW
0.45 0.60 0.75 1.1 0.6 0.75 1.1
Q
HP
m3/h
0
1.5
3.0
l/min
0
25
50
0.60 0.85 1 1.5 H metres 0.85 1 1.5
9 8.5 8 12 11.5 11 15 14.5 14 19.5 19 18.5 17 16.5 15 21 20 19 27 26 25
4.5
6.0
7.5
9.0
10.5 12.0
13.5 15.0 16.5 18.0
19.5 21.0 24.0
75
100
125
150
175 200
225
7.5 6.8 6 10.5 9.8 9 13.2 12.5 11.8 18 17.5 16.5 13.5 12 10.7 17.5 16 15 23.5 22 21
Q = Flow rate H = Total manometric head
5.2 4 8.2 7.2 11 10 16 15 9 7.7 13.5 12 19.5 18
2.6 1 6 4.8 9 8 14 13 5 10 16 14.5
250
275
300
325
350
400
3.5 2 6.8 5.4 11.8 10.5
3.5 9.2
2 8
7
4
13
11.5
10
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS a
Typicalsingle-phaseinstallation
h1
n
DN
e
p minimum
h
SINGLE-PHASE CONTROL PANEL
o c
b
TYPE Single-phase Three-phase DCm 6 ––– DCm 8 ––– DCm 10 DC10 DCm 15 DC15 DCm 18 ––– DCm 20 DC 20 DCm 30 DC 30
d
m
INLET DN
11/2" 11/2" 11/2"
11/2" 11/2" 11/2" 11/2"
a 105 105 105 110 105 105 105 110
b 90 90 90 90 90 90 90
c 136 136 136 140 136 136 136 140
h 285 285 285 310 285 285 285 310
h1 66 66 66 80 66 66 66 80
DIMENSIONS mm m n o 81 200 66 81 200 66 81 200 66 81 200 66 81 200 66 81 200 66 81 200 66
minimum kg
d 15 15 15 15 15 15 15
e p regolabile 500 regolabile 500 regolabile 500 adjustable regolabile 500 regolabile 500 regolabile 500 regolabile 500
500 500 500 500 500 500 500
1~ 14.8 16.1 17.1 19.3 16.1 17.1 19.3
3~ 16.1 18.2 16.1 18.2
VORTEX submersible electropumps forsewagewaters
VORTEX submersible pumps made of cast iron, particularly sturdy and reliable, indicated in fixed installations. Thanks to the well-tested vortex system it allows the evacuation of dirty waters containing suspended solid bodies.
RANGE OF PERFORMANCE Flow rate up to 500 l/min (30 m3/h) Head up to 15 m
CONSTRUCTIONCHARACTERISTICS ● l ● ●
LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of solid bodies max Ø 35 mm for VXC/35 Passage of solid bodies max Ø 45 mm for VXC/45 For continuous duty: minimum immersion 290 mm EXECUTION AND SAFETY STANDARDS EN 60034-1 60 335-1 IEC IEC 34-1 335-1 CEI CEI 2-3 61-150
EN 60034-1 IEC 34-1 CEI 2-3
● ●
●
●
PUMP BODY: cast iron, with threaded inlet ISO 228/1. MOTOR CASING AND BASE: cast iron. IMPELLER: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. VXCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding. VXC: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: VXC m (single-phase) Float switch. Cm Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. Electric panel with condenser(Protection IP 64).
USESANDINSTALLATIONS THE PUMPS IN THE VXC SERIES, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION, ARE EQUIPPED WITH A VORTEX TYPE IMPELLER, THEY ARE RECOMMENDED FOR DRAINING WASTE WATERS CONTAINING SUSPENDED SOLID BODIES, SEWAGE, WASTE WATERS AND WATERS MIXED WITH MUD.
GUARANTEE YEARS accordingto to our general termsterms of sale. of sale. GUARANTEE 12YEAR subject our general
VXC
(three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
VXC15/35
Head H (metres)
VXC15/45 VXC10/35
VXC8/35 VXC10/45 VXC8/45
Flow rate Q
TYPE Single-phase VXCm 8/35 VXCm 10/35 VXCm 15/35 VXCm 8/45 VXCm 10/45 VXCm 15/45
POWER
Three-phase ––– VXC 10/35 VXC 15/35 ––– VXC 10/45 VXC 15/45
kW
0.60 0.75 1.1 0.60 0.75 1.1
Q
HP
m3/h
0
3
6
9
12
15
18
21
24
27
30
l/min
0
50
100
150
200
250
300
350
400
450
500
8.4 10 15 6 7.5 11
7.5 9.5 14 5.5 7 10.5
6.5 8.5 13 5 6.5 10
5.2 7.2 11.8 4.4 5.8 9.5
3.7 5.8 10.5 3.6 5 9
2 4 9 2.8 4 8.3
2 7.5 2 3.2 7.5
6 1 2.4 6.8
4
2
1.5 6
5
0.85 1 1.5 H metres 0.85 1 1.5
Q = Flow rate H = Total manometric head
4
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typicalsingle-phaseinstallation a
SINGLE-PHASE CONTROL PANEL
e
h1
n
p minimum
h
DN
o b
TYPE Single-phase Three-phase VXCm 8/35 ––– VXCm 10/35 VXC 10/35 VXCm 15/35 VXC 15/35 VXCm 8/45 ––– VXCm 10/45 VXC 10/45 VXCm 15/45 VXC 15/45
INLET DN
11/2"
11/2" 11/2" 2"
2" 2"
passage of solid bodies
Ø 35 mm Ø 35 mm Ø 35 mm Ø 45 mm Ø 45 mm Ø 45 mm
a 105 105 105 110 110 110 120
c
b 87 90 87 92 90 90 90 97
d
m
c 137 137 137 143 150 150 150 163
h 350 350 350 370 375 375 375 395
h1 123 123 123 133 148 148 148 153
DIMENSIONS mm m n o 81 200 66 81 200 66 81 200 66 66 81 200 81 200 66 81 200 66 81 200 66
minimum
kg d 40 40 40 55 55 55
e p regolabile 500 regolabile 500 regolabile 500 adjustable 500 regolabile 500 regolabile 500 regolabile 500
500 500 500 500 500 500 500
1~ 17.0 18.7 20.9 18.0 19.7 21.9
3~ 17.1 19.8 18.0 20.8
TWO-CHANNEL submersible electropumps forsewagewaters
TWO-CHANNEL submersible pumps in cast iron, characterised by high yield; particularly sturdy and reliable, indicated in fixed installations.
RANGE OF PERFORMANCE Flow rate up to 800 l/min (48 m3/h) Head up to 15 m
GUARANTEE 1 YEAR subject to our terms of sale. GUARANTEE 2 YEARS according to ourgeneral general terms of sale.
CONSTRUCTIONCHARACTERISTICS ● l
LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of suspended solid bodies up to Ø 45 mm For continuous duty: minimum immersion 290 mm
● ● ● ●
●
EXECUTION AND SAFETY STANDARDS EN EN 60034-1 60 335-1 IEC IEC 34-1 335-1 CEI CEI 2-3 61-150
EN 60034-1 IEC 34-1 CEI 2-3
●
PUMP BODY: cast iron, with threaded inlet ISO 228/1. MOTOR CASING AND BASE: cast iron. IMPELLER: two-channel, in stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. DOUBLE MECHANICAL SEAL: carburundum - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous for continuous duty. MCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding. MC: three-phase 380÷415 V - 50 Hz. INSULATION: class F. ● PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: USESANDINSTALLATIONS THE PUMPS IN THE MC SERIES, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONGLASTING, ARE EQUIPPED WITH A TWO-CHANNEL IMPELLER WHICH ALLOWS THE DRAINAGE OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES WITH DIMENSIONS UP TO Ø 45 mm WITH SHORT FIBRE. THEY ARE RECOMMENDED FOR CONVEYING DRAINAGE WATERS AND SEWAGE, WASTE WATERS, WATERS MIXED WITH MUD, GROUNDWATER AND SURFACE WATERS FOR USES SUCH AS: CONDOMINIUMS, INDUSTRIES, MULTI-STOREY CAR PARKS, UNDERGROUND CAR PARKS, WASHING AREAS, ETC. .
Cm MC m
(single-phase) Float switch. Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. Electric panel with condenser.
MC
(three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒
electric panel for three-phase electropumps 1.1 kW single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
20
0
40
60
20
80
40
100
60
120
80
140
100
160
120
180
200
140
160
220 180
16
feet 50
MC15/45
14
45
40
12
Head H (metres)
MC10/45
35
10 30
8
25
6
20
15
4 10
2 5
0
0
100
0 0
200
300
400
10
20
TYPE Single-phase MCm 10/45 MCm 15/45
POWER
Three-phase MC 10/45 MC 15/45
Q
500
600
700
30
800
40
Flow rate Q
50
m3/h
0
3
6
9
12
15
18
21
24
27
30
36
42
48
l/min
0
50
100
150
200
250
300
350
400
450
500
600
700
800
12 15
10.7 14
9.7 13
8.7 12.3
7.8 11.5
6.8 10.5
5.9 9.7
5 8.8
4 8
3 7
2 6.2
4.5
2.7
1
kW
HP
0.75 1.1
1 H metres 1.5
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typicalsingle-phaseinstallation a
SINGLE-PHASE CONTROL PANEL
e
h1
n
p minimum
h
DN
o b
TYPE Single-phase MCm 10/45 MCm 15/45
INLET Three-phase MC 10/45 MC 15/45
DN
2" 2" 2"
passage of solid bodies
Ø 45 mm Ø 45 mm Ø 45 mm
c
a 110 120
b 90 97
d
m
c 150 163
h 375 395
h1 148 153
DIMENSIONS mm m n o 81 200 66 81 66 200 81 200 66
minimum
kg d 55 55 55
e p regolabile 500 adjustable 500 adjustable 500
500 500 500
1~ 19.9 22.1
3~ 18.3 21.0
VORTEX submersible electropumps forsewagewaters
VORTEX submersible pumps made of cast iron, particularly sturdyandreliable,indicatedinfixedinstallations,forcontinuous heavy-dutyuseonbuildingsitesandinindustries,recommended for pumping sewage and waste waters of all types with solid impurities.
RANGE OF PERFORMANCE Flow rate up to 1200 l/min (72 m3/h) Head up to 16 m
CONSTRUCTIONCHARACTERISTICS ● ● ● ●
LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of solid bodies max Ø 50 mm for VXC 15-20-30/50 Passage of solid bodies max Ø 70 mm for VXC 15-20-30/70 For continuous duty: minimum immersion 420 mm
●
●
PUMP BODY, MOTOR CASING: cast iron. IMPELLER: cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE MECHANICAL SEAL: carburundum - widia - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous, 2 pole, for continuous duty. VXCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW. - In the 2.2 kW single-phase versions the built-in motor protector is to be suitably connected to the coil of the contactor,
EXECUTION AND SAFETY STANDARDS VXC:
60034-1 EN 60 335-1 IEC 335-1 34-1 IEC CEI 61-150 2-3 CEI
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS THE PUMPS IN THE VXC SERIES, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONGLASTING, ARE EQUIPPED WITH A VORTEX TYPE IMPELLER, SO THEY ARE SUITABLE FOR DRAINING SOLID-LADEN WATERS, SEWAGE, WASTE WATERS, WATERS MIXED WITH MUD, STIRRED SLUDGE AND ROTTEN SLUDGE. THEY ARE INDICATED FOR INSTALLATION IN SEWERS, TUNNELS, EXCAVATIONS, CHANNELS, UNDERGROUND CAR PARKS, ETC.
three-phase 380÷415 V - 50 Hz. - In the three-phase versions , three thermal protectors, in series, are positioned in the winding, to be suitably connected to the coil of the contactor.
●
INSULATION: class F.
●
PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: VXC m (single-phase) Float switch. Cm Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. For powers from 1.1 to 1.5 kW, electric panel with condenser and motor protector with manual reset For power 2.2 kW electric panel type QES 300 MONO.
VXC
GUARANTEE YEARS accordingto to our general termsterms of sale. of sale. GUARANTEE 12YEAR subject our general
(three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONSONREQUEST
⇒ ⇒ ⇒ ⇒
electric panel for three-phase electropumps dual voltage: 230/400 V or 400/690 V single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
VXC30/50
Head H (metres)
VXC20/50
VXC15/50 VXC30/70
VXC20/70
VXC15/70
Flow rate Q
TYPE Single-phase VXCm 15/50 VXCm 20/50 VXCm 30/50 VXCm 15/70 VXCm 20/70 VXCm 30/70
POWER
Three-phase VXC 15/50 VXC 20/50 VXC 30/50 VXC 15/70 VXC 20/70 VXC 30/70
Q
0
m3/h
kW
HP
1.1 1.5 2.2 1.1 1.5 2.2
1.5 2 3 H metres 1.5 2 3
6
12
18
21
24
30
36
42
48
51
54
60
0
100
200
300
350
400
500
600
700
800
850
900
1000
11.5 13 16 6.5 8.5 11
10.5 12 15 ––– ––– –––
9.5 11 14 5.5 7.4 9.7
8.2 9.5 13 5 6.7 9
7.2 9 12.3 4.7 6.3 8.6
6.5 8 11.5 4.4 6 8.2
4.5 6.5 10 3.7 5.2 7.5
2 4.5 8 3 4.5 6.7
2 5.9 2.2 3.6 5.8
3.3 1.5 2.8 5
2 1 2.4 4.6
2 4.2
1 3.3
l/min
Q = Flow rate H = Total manometric head
66
72
1100 1200
2.5
1.5
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS Typicalsingle-phaseinstallation a
DN
e
h1
n
p minimum
h
SINGLE-PHASE CONTROL PANEL
o
c
b TYPE Single-phase Three-phase VXCm 15/50 VXC 15/50 VXCm 20/50 VXC 20/50 VXCm 30/50 VXC 30/50 VXCm 15/70 VXC 15/70 VXCm 20/70 VXC 20/70 VXCm 30/70 VXC 30/70
INLET DN
21/2"
21/2" 21/2" 3"
3" 3"
passage of solid bodies
Ø 50 mm Ø 50 mm Ø 50 mm Ø 70 mm Ø 70 mm Ø 70 mm
a 162 162 162 180 180 180
b 135 135 135 150 150 150
d
m
c h h1 212 490 188 490 212 490 188 212 500/490 188 240 530 530 230 240 530 230 240 540/530 230
DIMENSIONS mm m n o
81
200
85
minimum kg
d 75 75 75 85 85 85
e p regolabile 800 regolabile 800 regolabile 800 adjustable 800 regolabile 800 regolabile 800 regolabile 800
800 75 800 800 800 85 800
1~ 33.3 34.8 40.7 38.9 40.8 47.0
3~ 31.0 33.3 34.8 36.6 38.9 41.1
SINGLE-CHANNEL submersible electropumps forsewagewaters
SINGLE-.CHANNEL submersible pumps characterised by high yield, particularly sturdy and reliable, indicated in fixed installations, for continuous heavy-duty use on building sites andinindustries;recommendedforpumpingsewageandwaste waters of all types with solid impurities.
RANGE OF PERFORMANCE Flow rate up to 1600 l/min (96 m3/h) Head up to 24 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of solid bodies max Ø 50 mm for MC 15-20-30/50 Passage of solid bodies max Ø 70 mm for MC 30/70 For continuous duty: minimum immersion 420 mm
● ●
●
PUMP BODY, MOTOR CASING: cast iron. IMPELLER: single-channel, in cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE MECHANICAL SEAL: carburundum - widia - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous, 2 pole, for continuous duty. MCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW. - In the 2.2 kW single-phase versions the built-in motor protector is to be suitably connected to the coil of the contactor,
EXECUTION AND SAFETY STANDARDS EN EN 60034-1 60 335-1 IEC IEC 34-1 335-1 CEI CEI 2-3 61-150
MC:
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS THE ELECTROPUMPS IN THE MC SERIES, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONG-LASTING, ARE EQUIPPED WITH A SINGLE-CHANNEL IMPELLER WHICH ALLOWS THE DRAINAGE OF LIQUIDS CONTAINING SUSPENDED SOLID BODIES , WITH SHORT FIBRE, SO THEY ARE INDICATED FOR CONVEYING DRAINAGE WATERS AND SEWAGE, WASTE WATERS, WATERS MIXED WITH MUD, GROUNDWATER AND SURFACE WATERS FOR USES SUCH AS: CONDOMINIUMS, PUBLIC BUILDINGS, INDUSTRIES, MULTISTOREY CAR PARKS, UNDERGROUND CAR PARKS, WASHING AREAS, ETC. GUARANTEE 12 YEAR subject totoour general terms GUARANTEE YEARS according our general terms of sale. of sale.
three-phase 380÷415 V - 50 Hz. - In the three-phase versions , three thermal protectors, in series, are positioned in the winding, to be suitably connected to the coil of the contactor.
●
INSULATION: class F.
●
PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: MC m Cm
MC
(single-phase) Float switch. Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. For powers from 1.1 to 1.5 kW, electric panel with condenser and motor protector with manual reset For power 2.2 kW electric panel type QES 300 MONO. (three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
electric panel for three-phase electropumps dual voltage: 230/400 V or 400/690 V single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
MC30/50
Head H (metres)
MC20/50
MC15/50
MC30/70
Flow rate Q
TYPE Single-phase MCm 15/50 MCm 20/50 MCm 30/50 MCm 30/70
POWER
Three-phase MC 15/50 MC 20/50 MC 30/50 MC 30/70
0
3
6
0
50
100
16 18 24 13
––– 14 ––– 16 ––– 22 ––– –––
m3/h
Q
kW
HP
1.1 1.5 2.2 2.2
1.5 2 H metres 3 3
l/min
12
18
24
30
36
42
48
200 300
400
500
600
700
800
900 1000 1100 1200 1400 1600
12.5 10.5 8.5 14 12.5 10.5 20 18 16 11.5 11 10.2
7 9 14 9.5
5 7 12 8.8
3 5 10 8.2
1 3 8 7.6
1 6 6.8
Q = Flow rate H = Total manometric head
54
60
66
4 6
2 5.3
72
4.8
84
96
3.2
2
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Typicalsingle-phaseinstallation a
DN
e
h1
n
p minimum
h
SINGLE-PHASE CONTROL PANEL
o
c
b
TYPE Single-phase Three-phase MCm 15/50 MC 15/50 MCm 20/50 MC 20/50 MCm 30/50 MC 30/50 MCm 30/70 MC 30/70
INLET DN
21/2"
21/2" 21/2"
3"
passage of solid bodies
Ø 50 mm Ø 50 mm Ø 50 mm Ø 70 mm
a 162 162 162 180
b 135 135 135 150
d
m
c h h1 212 490 188 490 212 490 188 212 500/490 188 240 540/530 230
DIMENSIONS mm m n o 81
200
85
minimum
kg d 75 75 75 85
e regolabile regolabile regolabile regolabile regolabile
p 800 800 800 800 800
800 800 800 800 800
1~ 34.0 35.7 41.7 48.0
3~ 31.8 34.0 35.8 42.1
VORTEX submersible electropumps forsewagewaters
stationaryversion The pumps in the PVXC series are complete with a support foot, movable slide, tube guides and hydraulic couplings, for connectiontothesewernetwork.
RANGE OF PERFORMANCE Flow rate up to 1200 l/min (72 m3/h) Head up to 16 m LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of solid bodies max Ø 50 mm for PVXC 15-20-30/50 Passage of solid bodies max Ø 70 mm for PVXC 15-20-30/70 For continuous duty: minimum immersion 430 mm
CONSTRUCTIONCHARACTERISTICS ● ● ● ● ●
●
PUMPBODY,MOTORCASINGAND CONNECTINGFOOT:castiron. IMPELLER: cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE MECHANICAL SEAL: carburundum - widia - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous, 2 pole, for continuous duty. PVXCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW. - In the 2.2 kW single-phase versions the built-in motor protector is to be suitably connected to the coil of the contactor,
EXECUTION AND SAFETY STANDARDS EN EN 60034-1 60 335-1 IEC IEC 34-1 335-1 CEI CEI 2-3 61-150
EN 60034-1 IEC 34-1 CEI 2-3
PVXC:
three-phase 380÷415 V - 50 Hz. - In the three-phase versions , three thermal protectors, in series, are positioned in the winding, to be suitably connected to the coil of the contactor.
●
INSULATION: class F.
●
PROTECTION: IP 68.
USESANDINSTALLATIONS THE ELECTROPUMPS IN THE PVXC SERIES, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION AND LONG-LASTING, ARE EQUIPPED WITH A VORTEX TYPE IMPELLER, SO THEY ARE SUITABLE FOR DRAINING WASTE WATERS, WATERS MIXED WITH MUD, LIQUIDS CONTAINING AIR OR GAS, AS WELL AS STIRRED SLUDGE AND ROTTEN SLUDGE. THEY ARE RECOMMENDED FOR FIXED INSTALLATION IN SEWERS, TUNNELS, WELLS, UNDERGROUND CAR PARKS, IN SPECIAL TRAPS.
THE ELECTROPUMPS ARE COMPLETE WITH: Connecting foot Threaded counterflange on delivery Supports for guide tubes
PVXC m (single-phase) Flow switch. PVXCm Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. For powers from 1.1 to 1.5 kW, electric panel with condenser and motor protector with manual reset For power 2.2 kW electric panel type QES 300 MONO.
GUARANTEE 12YEAR subject our general GUARANTEE YEARS accordingto to our general termsterms of sale. of sale.
PVXC
(three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
electric panel for three-phase electropumps dual voltage : 230/400 V or 400/690 V single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PVXC30/50
Head H (metres)
PVXC20/50
PVXC15/50 PVXC30/70
PVXC20/70
PVXC15/70
Flow rate Q
TYPE Single-phase PVXCm 15/50 PVXCm 20/50 PVXCm 30/50 PVXCm 15/70 PVXCm 20/70 PVXCm 30/70
Three-phase PVXC 15/50 PVXC 20/50 PVXC 30/50 PVXC 15/70 PVXC 20/70 PVXC 30/70
POWER kW
HP
1.1 1.5 2.2 1.1 1.5 2.2
1.5 2 3 1.5 2 3
Q
m3/h
0
l/min
0
11.5 13 H metres 16 6.5 8.5 11
6
12
18
21
24
27
30
36
42
48
51
54
100
200
10.5 12 15 ––– ––– –––
9.5 11 14 5.5 7.4 9.7
300
350
400
450
500
600 700
800
850
900 1000 1100 1200
8.2 9.5 13 5 6.7 9
7.2 9 12.3 4.7 6.3 8.6
2 4.5 8 3 4.5 6.7
3.3 1.5 2.8 5
2 1 2.4 4.6
2 4.2
Q = Flow rate H = Total manometric head
6.5 5.6 4.5 8 7,2 6.5 11.5 10.8 10 4.4 4 3.7 6 5.6 5.2 8.2 7.8 7.5
2 5.9 2.2 3.6 5.8
60
1 3.3
66
2.5
72
1.5
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS a
Typicalinstallation
Guidetubes Ø external 27 mm maximum Ø internal 19.5÷21.5 mm
w DN
b
m
d
h
c
f
g
e n TYPE Single-phase Three-phase PVXCm 15/50 PVXC 15/50 PVXCm 20/50 PVXC 20/50 PVXCm 30/50 PVXC 30/50 PVXCm 15/70 PVXC 15/70 PVXCm 20/70 PVXC 20/70 PVXCm 30/70 PVXC 30/70
INLET DN
21/2"
21/2" 21/2" 3"
3" 3"
passage of solid bodies
Ø 50 mm Ø 50 mm Ø 50 mm Ø 70 mm Ø 70 mm Ø 70 mm
a 60 60 60 60 60 60 60
b 116 116 116 150 150 150
c 51 51 51 70 70 70
d 501 501 501 585 585 585
DIMENSIONS e f 62 270 62 270 62 270 95 300 95 300 95 300
mm g h m 10 387 200 387 10 387 200 10 397/387 200 10 10 405 256 405 10 405 256 10 415/405 256
kg* n w 1~ 3~ 120 72 42.0 40.0 120 72 43.8 42.3 120 72 49.7 43.8 150 92 53.0 50.7 150 92 54.9 53.0 150 92 61.1 55.2 (*weight with counterflange)
SINGLE-CHANNEL submersible electropumps forsewagewaters
stationaryversion The pumps in the PMC series are complete with a support foot, movable slide, tube guides and hydraulic couplings, for connectiontothesewernetwork.
RANGE OF PERFORMANCE Flow rate up to 1600 l/min (96 m3/h) Head up to 24 m
CONSTRUCTIONCHARACTERISTICS ● ● ●
LIMITS OF USE Depth of use up to 10 m Liquid temperature up to + 40°C Passage of solid bodies max Ø 50 mm for PMC 15-20-30/50 Passage of solid bodies max Ø 70 mm for PMC 30/70 For continuous duty: minimum immersion 430 mm
● ●
●
- In the 2.2 kW single-phase versions the built-in motor protector is to be suitably connected to the coil of the contactor.
EXECUTION AND SAFETY STANDARDS EN 60 60034-1 335-1 IEC 34-1 IEC 335-1 CEI 61-150 2-3 CEI
EN 60034-1 IEC 34-1 CEI 2-3
USESANDINSTALLATIONS THE ELECTROPUMPS IN THE PMC SERIES, MADE OF EXCEPTIONALLY STURDY HEAVY-GAUGE CAST IRON, RESISTANT TO ABRASION, ARE EQUIPPED WITH ASINGLE-CHANNEL IMPELLER IN CAST IRON WHICH ALLOWS THE DRAINAGE OF LIQUIDS CONTAINING SUSPENDED SOLID PARTS, WITH SHORT FIBRE. THEY ARE INDICATED FOR CONVEYING DRAINAGE WATERS AND SEWAGE, WASTE WATERS, WATERS MIXED WITH MUD, GROUNDWATER AND SURFACE WATERS FOR USES SUCH AS: CONDOMINIUMS, PUBLIC BUILDINGS, INDUSTRIES, MULTI-STOREY CAR PARKS, UNDERGROUND CAR PARKS, WASHING AREAS, IN SPECIAL TRAPS. GUARANTEE 1 2 YEAR subject to toour terms of sale. GUARANTEE YEARS according our general general terms of sale.
PUMPBODY,MOTORCASINGAND CONNECTINGFOOT:castiron. IMPELLER: single-channel, in cast iron. BASE: stainless steel AISI 304. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4057. DOUBLE MECHANICAL SEAL: carburundum - widia - NBR pump side and sealing ring on motor side (with interposed oil barrier chamber for lubricating and cooling the seal surfaces in case of lack of water). MOTOR: submersible asynchronous, 2 pole, for continuous duty. PMCm: single-phase 220÷240 V - 50 Hz with thermal overload protector built into the winding up to 1.5 kW.
PMC:
three-phase 380÷415 V - 50 Hz. - In the three-phase versions , three thermal protectors, in series, are positioned in the winding, to be suitably connected to the coil of the contactor.
●
INSULATION: class F.
●
PROTECTION: IP 68.
THE ELECTROPUMPS ARE COMPLETE WITH: Connecting foot Threaded counterflange on delivery Supports for guide tubes
PMC m PMCm
(single-phase) Float switch. Neoprene power cable "H07 RN-F" length 10 metres with Schuko plug. For powers from 1.1 to 1.5 kW, electric panel with condenser and motor protector with manual reset For power 2.2 kW electric panel type QES 300 MONO.
PMC
(three-phase) Neoprene power cable "H07 RN-F" length 10 metres.
EXECUTIONS ON REQUEST
⇒ ⇒ ⇒ ⇒
electric panel for three-phase electropumps dual voltage: 230/400 V or 400/690 V single-phase electropumps without float switch other voltages or frequency 60 Hz
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
PMC30/50
Head H (metres)
PMC20/50 PMC15/50
PMC30/70
Flow rate Q
TYPE Single-phase PMCm 15/50 PMCm 20/50 PMCm 30/50 PMCm 30/70
Three-phase PMC 15/50 PMC 20/50 PMC 30/50 PMC 30/70
POWER
Q
m3/h
0
6
0
kW
HP
l/min
1.1 1.5 2.2 2.2
1.5 2 3 3
16 H metres 18 24 13
12
15
18
24
30
36
42
100
200
250
300
400
500
600
700 800
900 1000 1100 1200 1400 1600
14 16 22 –––
12.5 11.5 10.5 14 13 12.5 20 19 18 11.5 11.2 11
8.5 10.5 16 10.2
7 9 14 9.5
5 7 12 8.8
3 5 10 8.2
1 6 6.8
Q = Flow rate H = Total manometric head
48
1 3 8 7.6
54
60
4 6
66
2 5.3
72
4.8
84
3.2
96
2
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS a
Typicalinstallation Guidetubes Ø external 27 mm maximum Ø internal 19.5÷21.5 mm
w DN
b
m
d
h
c
f
g
e n
TYPE Single-phase Three-phase PMCm 15/50 PMC 15/50 PMCm 20/50 PMC 20/50 PMCm 30/50 PMC 30/50 PMCm 30/70 PMC 30/70
INLET DN
21/2"
21/2" 21/2"
3"
passage of solid bodies
Ø 50 mm Ø 50 mm Ø 50 mm Ø 70 mm
a 60 60 60 60 60
b 116 116 116 150
c 51 51 51 70
d 501 501 501 585
DIMENSIONS e f 62 270 62 270 62 270 95 300
mm g h m 10 387 200 387 10 387 200 10 10 397/387 200 10 415/405 256
kg* n w 1~ 3~ 120 72 43.0 40.8 120 72 44.7 43.0 120 72 50.7 44.8 150 92 62.0 56.1 (*weight with counterflange)
portableself-primingelectropumps
RANGE OF PERFORMANCE Flow range up to 50 l/min (3 m3/h) Head up to 70 m
GUARANTEE YEARS accordingto to our general terms of sale. of sale. subject our general terms GUARANTEE 12YEAR CONSTRUCTIONCHARACTERISTICS ●
LIMITS OF USE Manometric suction height up to 9 m Liquid temperature up to + 40°C Environment temperature up to + 40°C EXECUTIONANDSAFETYSTANDARDS
● ●
● ●
EN 60 335-1 IEC 335-1 CEI 61-150
EN 60034-1 IEC 34-1 CEI 2-3
●
●
PUMP BODY:
BETTY: cast iron; BETTYNOX: stainless steel AISI 304. BETTY 60, 65, 70, 80: CHECK FLAP VALVE built into the suction inlet. IMPELLER: BETTY 60, 65, 70, 80: brass, type with radial peripheral vanes; BETTY 1, 2, 3 BETTYNOX:technopolymer, centrifugal type. MOTOR SHAFT: stainless steel EN 10088-3 - 1.4104. MECHANICAL SEAL: ceramic - graphite - NBR. ELECTRIC MOTOR : induction motor, for continuous duty. Single-phase: 230 V - 50 Hz with condenser and thermal overload protector built into the winding . INSULATION: class F. ● PROTECTION: IP 44.
USESANDINSTALLATIONS
THE ELECTROPUMPS ARE COMPLETE WITH:
PORTABLE SELF-PRIMING ELECTROPUMPS ABLE TO EXPEL ANY AIR BUBBLES MIXED WITH THE WATER, PRESENT IN THE SUCTION PIPE. RECOMMENDED FOR: GARDENING, VEGETABLE GARDENS, WASHING, HOBBY APPLICATIONS AND THEY ARE SUITABLE FOR CONVEYING LIQUIDS COMPATIBLE WITH THE COMPONENTS OF WHICH THE PUMP IS MADE.
BETTY
Carrying handle. Hosetails Ø 20 mm. 1.5 m power cable with Schuko plug.
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
BETTY 80 BETTY 70
BETTY 60
Head H
(metres)
BETTY 65
Flow rate Q
TYPE Single-phase BETTY 60 BETTY 65 BETTY 70 BETTY 80
POWER kW
Q
HP
0.37 0.50 0.60 0.75
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
5
10
15
20
25
30
35
40
45
50
40 55 65 70
38 50 62 66
33.5 45.5 57 61
29 40.5 52 56
24 36 47 51
19.5 31 42 46
15 27 37 41
10 22 32 36.5
5 17 27 31
12.5 22 27
8 18 22
0.50 0.70 H metres 0.85 1
Q = Flow rate H = Total manometric head
Tolerance of the performance curves according to EN ISO 9906 App. A.
DIMENSIONSANDWEIGHTS
Ø2
n1
h1
h
Ø1
DN1
DN2
f
TYPE Single-phase BETTY 60 BETTY 65 BETTY 70 BETTY 80
n
INLETS DN1
DN2
1"
1"
1" 1”
1" 1”
1" 1"
1" 1"
Ø1
Ø2
20
20
f 270 270 270 277 277 277
DIMENSIONS mm h h1 273 267 273 267 267 273 273 267 273 267
kg n 220 220 220 220 220
n1 160 160 160 160 160
7.9 9.5 12.6 12.8
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
BETTY 3
BETTY 2
Head H
(metres)
BETTY 1
Flow rate Q
TYPE
POWER
Single-phase BETTY 1 BETTY 2 BETTY 3
kW
Q
HP
0.37 0.50 0.60
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
5
10
15
20
25
30
35
40
45
50
35 41 47
32 36 42
27 31 38
24 27 34
21 24 31
19 22 28.5
17 20 26
16 19 24
15 17 22
14 16 21.5
13 15 19
0.50 0.70 H metres 0.85
Q = Flow rate H = Total manometric head Hs = Suction height
Tolerance of the performance curves according to EN ISO 9906 App. A.
Ø2
DIMENSIONSANDWEIGHTS
h
h1
Ø1
DN1
DN2
f1 f
TYPE Single-phase BETTY 1 BETTY 2 BETTY 3
n
INLETS DN1
DN2
1"
1"
1" 1”
1" 1”
1"
1"
Ø1
Ø2
20
20
f 439 439 439 447
DIMENSIONS mm f1 h 379 379 379 260 387
kg h1
n
255
230
10.0 10.7 10.9
CURVES AND PERFORMANCE DATA AT n= 2900 1/min
BETTYNOX 3
BETTYNOX 2
Head H
(metres)
BETTYNOX 1
Flow rate Q
TYPE
POWER
Single-phase BETTYNOX 1 BETTYNOX 2 BETTYNOX 3
kW
Q
HP
0.37 0.50 0.60
m3/h
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
l/min
0
5
10
15
20
25
30
35
40
45
50
35 41 47
32 36 42
27 31 38
24 27 34
21 24 31
19 22 28.5
17 20 26
16 19 24
15 17 22
14 16 21.5
13 15 19
0.50 0.70 H metres 0.85
Q = Flow rate H = Total manometric head Hs = Suction height
Tolerance of the performance curves according to EN ISO 9906 App. A.
Ø2
DIMENSIONSANDWEIGHTS
h
Ø1
h1
DN1
DN2
f1 n
f
TYPE Single-phase BETTYNOX 1 BETTYNOX 2 BETTYNOX 3
INLETS DN1
DN2
1"
1"
1" 1”
1" 1”
1"
1"
Ø1
Ø2
20
20
f 439 405 439 413
DIMENSIONS mm f1 h 379 345 379 270 353
kg h1
n
260
198
7.9 8.0 9.2
Smallautoclavesetswith 20litrecylindricaltank,with automatic operation, suitable for the distribution of pressurisedwaterinthehomeorinholidayhomes.
PERFORMANCE AND DIMENSIONS
Single-phase
suc. deliv.
kW
HP
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"
0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.55 0.75 1.1 1.1 0.75 1.1 1.1 0.45 0.60 0.60 0.75 0.45 0.60 0.60 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1
0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 0.75 1 1.5 1.5 1 1.5 1.5 0.60 0.85 0.85 1 0.60 0.85 0.85 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5
PKm 60 - 24 CL PKm 65 - 24 CL PKm 70 - 24 CL PKm 80 - 24 CL PKm 100 - 24 CL PKSm 60 - 24 CL PKSm 65 - 24 CL PKSm 70 - 24 CL PKSm 80 - 24 CL CPm 152 - 24 CL CPm 158 - 24 CL CPm 170 - 24 CL CPm 170M-24 CL 2CPm 25/130N - 24 CL 2CPm 25/140H - 24 CL 2CPm 25/140M - 24 CL 3CPm 80E - 24 CL 4CPm 80E - 24 CL 3CPm 100E- 24 CL 4CPm 100E- 24 CL 3CRm 80 - 24 CL 4CRm 80 - 24 CL 3CRm 100 - 24 CL JSWm 1C - 24 CL JSWm 1B - 24 CL JSWm 1A - 24 CL JSWm 10H - 24 CL JSWm 12H - 24 CL JSWm 15H - 24 CL JSWm 10M - 24 CL JSWm 12M - 24 CL JSWm 15M - 24 CL JSWm 3CH - 24 CL JSWm 3CM- 24 CL JSWm 3CL - 24 CL JCRm 1C - 24 CL JCRm 1B - 24 CL JCRm 1A - 24 CL JCRm 10H - 24 CL JCRm 12H - 24 CL JCRm 15H - 24 CL JCRm 10M - 24 CL JCRm 12M - 24 CL JCRm 15M - 24 CL
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
POWER
FLOW SETTING RATE (recommended) (2) (1) min max
l/min 32 40 50 50 50 32 40 50 50 80 90 120 150 100 100 140 60 60 100 100 60 60 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80
1.4 1.5 1.8 2.2 3.5 1.4 1.5 1.8 2.2 1.4 1.8 2.2 2.0 1.4 2.2 2.2 1.4 2.2 1.4 2 1.4 2.2 1.4 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5
2.8 3.0 3.2 3.6 4.5 2.8 3.0 3.2 3.6 2.8 3.2 3.5 3.5 2.8 3.6 3.6 2.8 3.6 2.8 3.5 2.8 3.6 2.8 2.6 2.8 3.2 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0
DIMENSIONS mm
l
a
h
540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540
255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 265 265 265 315 315 315 315 315 315 290 290 290 255 255 255 255 255 255 255 255 255
475 480 490 490 510 540 540 550 550 580 580 595 595 538 562 562 510 510 510 510 509 509 509 497 497 497 515 515 515 515 515 515 545 545 545 509 509 509 539 539 539 539 539 539
DN2
h
INLETS
DN1
TYPE
l
a
HYDROFRESH24CLCOMPONENTS - Single-phase electropump - 20 litre cylindrical tank - Hose - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended)
N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
Smallautoclavesetswith 24litresphericaltank,with automatic operation, suitable for the distribution of pressurisedwaterinthehomeorinholidayhomes.
PERFORMANCE AND DIMENSIONS
suc. deliv.
kW
HP
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"
0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.55 0.75 1.1 1.1 0.75 1.1 1.1 0.45 0.60 0.60 0.75 0.45 0.60 0.60 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1
0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 0.75 1 1.5 1.5 1 1.5 1.5 0.60 0.85 0.85 1 0.60 0.85 0.85 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5
PKm 60 - 24 SF PKm 65 - 24 SF PKm 70 - 24 SF PKm 80 - 24 SF PKm 100 - 24 SF PKSm 60 - 24 SF PKSm 65 - 24 SF PKSm 70 - 24 SF PKSm 80 - 24 SF CPm 152 - 24 SF CPm 158 - 24 SF CPm 170 - 24 SF CPm 170M-24 SF 2CPm 25/130N - 24 SF 2CPm 25/140H - 24 SF 2CPm 25/140M - 24 SF 3CPm 80E - 24 SF 4CPm 80E - 24 SF 3CPm 100E - 24 SF 4CPm 100E - 24 SF 3CRm 80 - 24 SF 4CRm 80 - 24 SF 3CRm 100 - 24 SF JSWm 1C - 24 SF JSWm 1B - 24 SF JSWm 1A - 24 SF JSWm 10H - 24 SF JSWm 12H - 24 SF JSWm 15H - 24 SF JSWm 10M - 24 SF JSWm 12M - 24 SF JSWm 15M - 24 SF JSWm 3CH - 24 SF JSWm 3CM - 24 SF JSWm 3CL - 24 SF JCRm 1C - 24 SF JCRm 1B - 24 SF JCRm 1A - 24 SF JCRm 10H - 24 SF JCRm 12H - 24 SF JCRm 15H - 24 SF JCRm 10M - 24 SF JCRm 12M - 24 SF JCRm 15M - 24 SF
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
FLOW SETTING RATE (recommended) (2) (1) min max
l/min 32 40 50 50 50 32 40 50 50 80 90 120 150 100 100 140 60 60 100 100 60 60 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80
1.4 1.5 1.8 2.2 3.5 1.4 1.5 1.8 2.2 1.4 1.8 2.2 2.0 1.4 2.2 2.2 1.4 2.2 1.4 2 1.4 2.2 1.4 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5
2.8 3.0 3.2 3.6 4.5 2.8 3.0 3.2 3.6 2.8 3.2 3.5 3.5 2.8 3.6 3.6 2.8 3.6 2.8 3.5 2.8 3.6 2.8 2.6 2.8 3.2 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0
DIMENSIONS mm
l
a
h
381 389 409 409 447 381 389 409 409 434 434 470 470 437 462 462 401 408 408 423 435 443 423 434 434 441 460 460 460 460 460 460 522 522 522 435 435 443 460 460 460 460 460 460
360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360
513 518 531 531 549 565 565 577 577 617 617 635 635 576 599 599 550 550 550 550 548 548 548 536 536 536 555 555 555 555 555 555 583 583 583 548 548 548 579 579 579 579 579 579
l
a
h
Sungle-phase
POWER
DN2
INLETS
DN1
TYPE
HYDROFRESH24SFCOMPONENTS - Single-phase electropump 230 V - 50 Hz - 24 litre spherical tank - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended)
N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
Autoclavesetswith60litrecylindricaltank,withautomatic operation,suitableforthedistributionofpressurisedwater in the home .
PERFORMANCE AND DIMENSIONS
Single-phase
suc.
POWER
deliv. kW
HP
FLOW SETTING RATE (recommended) (2) (1) min max
DIMENSIONS mm
a
h
50
2.2
3.6
750
380
630
1
90
1.8
3.2
750
380
720
1.5
120
2.2
3.5
750
380
735
1.1
1.5
150
2.0
3.5
750
380
735
1"
0.75
1
100
1.4
2.8
750
380
678
1"
1.1
1.5
100
2.2
3.6
750
380
702 702
1"
1"
0.75
1
CPm 158 - 60 CL
1"
1"
0.75
CPm 170 - 60 CL
11/4"
1"
1.1
CPm 170M-60 CL
11/4"
1"
2CPm 25/130N - 60 CL
11/4"
2CPm 25/140H - 60 CL
11/4"
2CPm 25/140M - 60 CL
l/min
l
DN2
h
PKSm 80 - 60 CL
INLETS
11/2"
1"
1.1
1.5
140
2.2
3.6
750
380
4CPm 100E- 60 CL
1"
1"
0.75
1
100
2
3.5
750
380
650
JSWm 10H - 60 CL
1"
1"
0.75
1
50
2.0
3.2
750
380
655
JSWm 12H - 60 CL
1"
1"
0.90
1.25
50
2.5
4.0
750
380
655
JSWm 15H - 60 CL
1"
1"
1.1
1.5
50
3.0
4.5
750
380
655
JSWm 10M - 60 CL
1"
1"
0.75
1
80
1.4
2.8
750
380
655
JSWm 12M - 60 CL
1"
1"
0.90
1.25
80
2.0
3.5
750
380
655
JSWm 15M - 60 CL
1"
1"
1.1
1.5
80
2.5
4.0
750
380
655
JSWm 3CH - 60 CL
11/4"
1"
1.1
1.5
70
3.0
4.5
750
380
685
JSWm 3CM- 60 CL
11/4"
1"
1.1
1.5
120
2.0
3.5
750
380
685
JSWm 3CL - 60 CL
11/4"
1"
1.1
1.5
160
1.4
2.8
750
380
685
JCRm 10H - 60 CL
11/4"
1"
0.75
1
50
2.0
3.4
750
380
679
JCRm 12H - 60 CL
11/4"
1"
0.90
1.25
50
2.4
3.8
750
380
679
JCRm 15H - 60 CL
11/4"
1"
1.1
1.5
50
3.0
4.0
750
380
679
JCRm 10M - 60 CL
11/4"
1"
0.75
1
80
1.4
2.8
750
380
679
JCRm 12M - 60 CL
11/4"
1"
0.90
1.25
80
2.0
3.5
750
380
679
JCRm 15M - 60 CL
11/4"
1"
1.1
1.5
80
2.5
4.0
750
380
679
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch. (2) Pressure switch setting (recommended) N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
l
HYDROFRESH60CLCOMPONENTS - Single-phase electropump - 60 litre cylindrical tank - Hose - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
DN1
TYPE
a
Autoclavesetswith100litrecylindricaltank,withautomatic operation,suitableforthedistributionofpressurisedwater in the home .
PERFORMANCE AND DIMENSIONS
Single-phase
suc. deliv.
kW
HP
- 100 CL
11/4"
1"
1.1
1.5
120
2.2
CPm 170M - 100 CL
11/4"
1"
1.1
1.5
150
2.0
2CPm 25/130N - 100 CL 11/4"
1"
0.75
1
100
2CPm 25/140H - 100 CL 11/4"
1"
1.1
1.5
CPm 170
POWER
DIMENSIONS mm
DN2
l
a
h
3.5
860
450
800
3.5
860
450
800
1.4
2.8
860
450
743
100
2.2
3.6
860
450
767 767
l/min
2CPm 25/140M -100 CL 11/2"
1"
1.1
1.5
140
2.2
3.6
860
450
4CPm 100E - 100 CL
1"
1"
0.75
1
100
2
3.5
860
450
715
JSWm 10H - 100 CL
1"
1"
0.75
1
50
2.0
3.2
860
450
720
JSWm 12H - 100 CL
1"
1"
0.90
1.25
50
2.5
4.0
860
450
720
JSWm 15H - 100 CL
1"
1"
1.1
1.5
50
3.0
4.5
860
450
720
JSWm 10M - 100 CL
1"
1"
0.75
1
80
1.4
2.8
860
450
720
JSWm 12M - 100 CL
1"
1"
0.90
1.25
80
2.0
3.5
860
450
720
JSWm 15M - 100 CL
1"
1"
1.1
1.5
80
2.5
4.0
860
450
720
JSWm 3CH - 100 CL
11/4"
1"
1.1
1.5
70
3.0
4.5
860
450
750
JSWm 3CM - 100 CL
11/4"
1"
1.1
1.5
120
2.0
3.5
860
450
750
JSWm 3CL - 100 CL
11/4"
1"
1.1
1.5
160
1.4
2.8
860
450
750
JCRm 10H - 100 CL
11/4"
1"
0.75
1
50
2.0
3.4
860
450
744
JCRm 12H - 100 CL
11/4"
1"
0.90
1.25
50
2.4
3.8
860
450
744
JCRm 15H - 100 CL
11/4"
1"
1.1
1.5
50
3.0
4.0
860
450
744
JCRm 10M - 100 CL
11/4"
1"
0.75
1
80
1.4
2.8
860
450
744
JCRm 12M - 100 CL
11/4"
1"
0.90
1.25
80
2.0
3.5
860
450
744
JCRm 15M - 100 CL
11/4"
1"
1.1
1.5
80
2.5
4.0
860
450
744
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended) N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
DN1
INLETS
h
FLOW SETTING RATE (recommended) (2) (1) min max
TYPE
l
HYDROFRESH100CLCOMPONENTS - Single-phase electropump - 100 litre cylindrical tank - Hose - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
a
Autoclavesetswith100litrecylindricaltank,withautomatic operation,suitableforthedistributionofpressurisedwater in the home .
PERFORMANCE AND DIMENSIONS
Single-phase
suc. deliv.
kW
HP
- 100 CL
11/4"
1"
1.1
1.5
120
2.2
CPm 170M - 100 CL
11/4"
1"
1.1
1.5
150
2.0
2CPm 25/130N - 100 CL 11/4"
1"
0.75
1
100
2CPm 25/140H - 100 CL 11/4"
1"
1.1
1.5
CPm 170
POWER
DIMENSIONS mm
DN2
l
a
h
3.5
860
450
800
3.5
860
450
800
1.4
2.8
860
450
743
100
2.2
3.6
860
450
767 767
l/min
2CPm 25/140M -100 CL 11/2"
1"
1.1
1.5
140
2.2
3.6
860
450
4CPm 100E - 100 CL
1"
1"
0.75
1
100
2
3.5
860
450
715
JSWm 10H - 100 CL
1"
1"
0.75
1
50
2.0
3.2
860
450
720
JSWm 12H - 100 CL
1"
1"
0.90
1.25
50
2.5
4.0
860
450
720
JSWm 15H - 100 CL
1"
1"
1.1
1.5
50
3.0
4.5
860
450
720
JSWm 10M - 100 CL
1"
1"
0.75
1
80
1.4
2.8
860
450
720
JSWm 12M - 100 CL
1"
1"
0.90
1.25
80
2.0
3.5
860
450
720
JSWm 15M - 100 CL
1"
1"
1.1
1.5
80
2.5
4.0
860
450
720
JSWm 3CH - 100 CL
11/4"
1"
1.1
1.5
70
3.0
4.5
860
450
750
JSWm 3CM - 100 CL
11/4"
1"
1.1
1.5
120
2.0
3.5
860
450
750
JSWm 3CL - 100 CL
11/4"
1"
1.1
1.5
160
1.4
2.8
860
450
750
JCRm 10H - 100 CL
11/4"
1"
0.75
1
50
2.0
3.4
860
450
744
JCRm 12H - 100 CL
11/4"
1"
0.90
1.25
50
2.4
3.8
860
450
744
JCRm 15H - 100 CL
11/4"
1"
1.1
1.5
50
3.0
4.0
860
450
744
JCRm 10M - 100 CL
11/4"
1"
0.75
1
80
1.4
2.8
860
450
744
JCRm 12M - 100 CL
11/4"
1"
0.90
1.25
80
2.0
3.5
860
450
744
JCRm 15M - 100 CL
11/4"
1"
1.1
1.5
80
2.5
4.0
860
450
744
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended) N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
DN1
INLETS
h
FLOW SETTING RATE (recommended) (2) (1) min max
TYPE
l
HYDROFRESH100CLCOMPONENTS - Single-phase electropump - 100 litre cylindrical tank - Hose - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
a
Autoclavesetswith60litrecylindricaltank,withautomatic operation,suitableforthedistributionofpressurisedwater in the home .
PERFORMANCE AND DIMENSIONS
Single-phase
suc.
POWER
deliv. kW
HP
FLOW SETTING RATE (recommended) (2) (1) min max
DIMENSIONS mm
a
h
50
2.2
3.6
750
380
630
1
90
1.8
3.2
750
380
720
1.5
120
2.2
3.5
750
380
735
1.1
1.5
150
2.0
3.5
750
380
735
1"
0.75
1
100
1.4
2.8
750
380
678
1"
1.1
1.5
100
2.2
3.6
750
380
702 702
1"
1"
0.75
1
CPm 158 - 60 CL
1"
1"
0.75
CPm 170 - 60 CL
11/4"
1"
1.1
CPm 170M-60 CL
11/4"
1"
2CPm 25/130N - 60 CL
11/4"
2CPm 25/140H - 60 CL
11/4"
2CPm 25/140M - 60 CL
l/min
l
DN2
h
PKSm 80 - 60 CL
INLETS
11/2"
1"
1.1
1.5
140
2.2
3.6
750
380
4CPm 100E- 60 CL
1"
1"
0.75
1
100
2
3.5
750
380
650
JSWm 10H - 60 CL
1"
1"
0.75
1
50
2.0
3.2
750
380
655
JSWm 12H - 60 CL
1"
1"
0.90
1.25
50
2.5
4.0
750
380
655
JSWm 15H - 60 CL
1"
1"
1.1
1.5
50
3.0
4.5
750
380
655
JSWm 10M - 60 CL
1"
1"
0.75
1
80
1.4
2.8
750
380
655
JSWm 12M - 60 CL
1"
1"
0.90
1.25
80
2.0
3.5
750
380
655
JSWm 15M - 60 CL
1"
1"
1.1
1.5
80
2.5
4.0
750
380
655
JSWm 3CH - 60 CL
11/4"
1"
1.1
1.5
70
3.0
4.5
750
380
685
JSWm 3CM- 60 CL
11/4"
1"
1.1
1.5
120
2.0
3.5
750
380
685
JSWm 3CL - 60 CL
11/4"
1"
1.1
1.5
160
1.4
2.8
750
380
685
JCRm 10H - 60 CL
11/4"
1"
0.75
1
50
2.0
3.4
750
380
679
JCRm 12H - 60 CL
11/4"
1"
0.90
1.25
50
2.4
3.8
750
380
679
JCRm 15H - 60 CL
11/4"
1"
1.1
1.5
50
3.0
4.0
750
380
679
JCRm 10M - 60 CL
11/4"
1"
0.75
1
80
1.4
2.8
750
380
679
JCRm 12M - 60 CL
11/4"
1"
0.90
1.25
80
2.0
3.5
750
380
679
JCRm 15M - 60 CL
11/4"
1"
1.1
1.5
80
2.5
4.0
750
380
679
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch. (2) Pressure switch setting (recommended) N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
l
HYDROFRESH60CLCOMPONENTS - Single-phase electropump - 60 litre cylindrical tank - Hose - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
DN1
TYPE
a
Smallautoclavesetswith 24litresphericaltank,with automatic operation, suitable for the distribution of pressurisedwaterinthehomeorinholidayhomes.
PERFORMANCE AND DIMENSIONS
suc. deliv.
kW
HP
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"
0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.55 0.75 1.1 1.1 0.75 1.1 1.1 0.45 0.60 0.60 0.75 0.45 0.60 0.60 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1
0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 0.75 1 1.5 1.5 1 1.5 1.5 0.60 0.85 0.85 1 0.60 0.85 0.85 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5
PKm 60 - 24 SF PKm 65 - 24 SF PKm 70 - 24 SF PKm 80 - 24 SF PKm 100 - 24 SF PKSm 60 - 24 SF PKSm 65 - 24 SF PKSm 70 - 24 SF PKSm 80 - 24 SF CPm 152 - 24 SF CPm 158 - 24 SF CPm 170 - 24 SF CPm 170M-24 SF 2CPm 25/130N - 24 SF 2CPm 25/140H - 24 SF 2CPm 25/140M - 24 SF 3CPm 80E - 24 SF 4CPm 80E - 24 SF 3CPm 100E - 24 SF 4CPm 100E - 24 SF 3CRm 80 - 24 SF 4CRm 80 - 24 SF 3CRm 100 - 24 SF JSWm 1C - 24 SF JSWm 1B - 24 SF JSWm 1A - 24 SF JSWm 10H - 24 SF JSWm 12H - 24 SF JSWm 15H - 24 SF JSWm 10M - 24 SF JSWm 12M - 24 SF JSWm 15M - 24 SF JSWm 3CH - 24 SF JSWm 3CM - 24 SF JSWm 3CL - 24 SF JCRm 1C - 24 SF JCRm 1B - 24 SF JCRm 1A - 24 SF JCRm 10H - 24 SF JCRm 12H - 24 SF JCRm 15H - 24 SF JCRm 10M - 24 SF JCRm 12M - 24 SF JCRm 15M - 24 SF
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
FLOW SETTING RATE (recommended) (2) (1) min max
l/min 32 40 50 50 50 32 40 50 50 80 90 120 150 100 100 140 60 60 100 100 60 60 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80
1.4 1.5 1.8 2.2 3.5 1.4 1.5 1.8 2.2 1.4 1.8 2.2 2.0 1.4 2.2 2.2 1.4 2.2 1.4 2 1.4 2.2 1.4 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5
2.8 3.0 3.2 3.6 4.5 2.8 3.0 3.2 3.6 2.8 3.2 3.5 3.5 2.8 3.6 3.6 2.8 3.6 2.8 3.5 2.8 3.6 2.8 2.6 2.8 3.2 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0
DIMENSIONS mm
l
a
h
381 389 409 409 447 381 389 409 409 434 434 470 470 437 462 462 401 408 408 423 435 443 423 434 434 441 460 460 460 460 460 460 522 522 522 435 435 443 460 460 460 460 460 460
360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360
513 518 531 531 549 565 565 577 577 617 617 635 635 576 599 599 550 550 550 550 548 548 548 536 536 536 555 555 555 555 555 555 583 583 583 548 548 548 579 579 579 579 579 579
l
a
h
Sungle-phase
POWER
DN2
INLETS
DN1
TYPE
HYDROFRESH24SFCOMPONENTS - Single-phase electropump 230 V - 50 Hz - 24 litre spherical tank - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended)
N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
Smallautoclavesetswith 20litrecylindricaltank,with automatic operation, suitable for the distribution of pressurisedwaterinthehomeorinholidayhomes.
PERFORMANCE AND DIMENSIONS
Single-phase
suc. deliv.
kW
HP
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/2" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 11/4" 11/4" 11/4" 1" 1" 1" 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"
0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.55 0.75 1.1 1.1 0.75 1.1 1.1 0.45 0.60 0.60 0.75 0.45 0.60 0.60 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1
0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 0.75 1 1.5 1.5 1 1.5 1.5 0.60 0.85 0.85 1 0.60 0.85 0.85 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5
PKm 60 - 24 CL PKm 65 - 24 CL PKm 70 - 24 CL PKm 80 - 24 CL PKm 100 - 24 CL PKSm 60 - 24 CL PKSm 65 - 24 CL PKSm 70 - 24 CL PKSm 80 - 24 CL CPm 152 - 24 CL CPm 158 - 24 CL CPm 170 - 24 CL CPm 170M-24 CL 2CPm 25/130N - 24 CL 2CPm 25/140H - 24 CL 2CPm 25/140M - 24 CL 3CPm 80E - 24 CL 4CPm 80E - 24 CL 3CPm 100E- 24 CL 4CPm 100E- 24 CL 3CRm 80 - 24 CL 4CRm 80 - 24 CL 3CRm 100 - 24 CL JSWm 1C - 24 CL JSWm 1B - 24 CL JSWm 1A - 24 CL JSWm 10H - 24 CL JSWm 12H - 24 CL JSWm 15H - 24 CL JSWm 10M - 24 CL JSWm 12M - 24 CL JSWm 15M - 24 CL JSWm 3CH - 24 CL JSWm 3CM- 24 CL JSWm 3CL - 24 CL JCRm 1C - 24 CL JCRm 1B - 24 CL JCRm 1A - 24 CL JCRm 10H - 24 CL JCRm 12H - 24 CL JCRm 15H - 24 CL JCRm 10M - 24 CL JCRm 12M - 24 CL JCRm 15M - 24 CL
1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
POWER
FLOW SETTING RATE (recommended) (2) (1) min max
l/min 32 40 50 50 50 32 40 50 50 80 90 120 150 100 100 140 60 60 100 100 60 60 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80
1.4 1.5 1.8 2.2 3.5 1.4 1.5 1.8 2.2 1.4 1.8 2.2 2.0 1.4 2.2 2.2 1.4 2.2 1.4 2 1.4 2.2 1.4 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5
2.8 3.0 3.2 3.6 4.5 2.8 3.0 3.2 3.6 2.8 3.2 3.5 3.5 2.8 3.6 3.6 2.8 3.6 2.8 3.5 2.8 3.6 2.8 2.6 2.8 3.2 3.2 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0
DIMENSIONS mm
l
a
h
540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540 540
255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 265 265 265 315 315 315 315 315 315 290 290 290 255 255 255 255 255 255 255 255 255
475 480 490 490 510 540 540 550 550 580 580 595 595 538 562 562 510 510 510 510 509 509 509 497 497 497 515 515 515 515 515 515 545 545 545 509 509 509 539 539 539 539 539 539
DN2
h
INLETS
DN1
TYPE
l
a
HYDROFRESH24CLCOMPONENTS - Single-phase electropump - 20 litre cylindrical tank - Hose - Pressure switch“SQUARE-D” - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended)
N.B. The preloading of air in diaphragm tanks must be regulated at a value 0.2 bar lower than the minimum regulating value of the pressure switch.
convertibleautomaticsetsforautoclaves
CB2-VL
CB2-F
CB2-2CP
CB2-CP
COMBIPRESS are sets composed of two electropumps for lifting and
CB2-JSW
subject to our general terms of sale. GUARANTEE 1 YEAR GUARANTEE 2 YEARS according to our general terms of sale.
pressurising water, the range satisfies the demands for use in the domestic, civil, agricultural and industrial field.
CONSTRUCTIONCHARACTERISTICS PRINCIPLE OF OPERATION
● l
COMBIPRESS are pressure booster sets in which two electropumps are
asxsembled in a unit ready for installation. The sets are arranged in such a way that, at each increase in the request from the user, one or both of the pumps start automatically in succession. In this way there is a sure energy saving, because only the pumps necessary to satisfy the demand for water are started. The electronic circuit in the electric panel alternates the pump operation.
USES Clean water and chemically non aggressive liquids. - Water supply: pressure boosting for industry, condominiums, hotels, communities, water treatment plants, camping sites, schools, hospitals, barracks, etc. - Irrigation: sports grounds in general (football grounds, golf courses, etc.), farming crops, artifical snow systems.
● ●
●
ELECTROPUMPS complete with suction and delivery manifolds, ball valves and non return valves. BASE made of powder-painted metal sections. Command and control COMPONENTS installed on the delivery manifold and composed of the pressure gauge, two pressure switches that may be set by the user (the factory setting is regulated on a mean range of use of the set, given in the following tables). ELECTRIC PANEL with door blocking switch, low voltage pressure switch control circuit, electronic circuit for alternating the operation of the electropumps, thermal protection (motor protector) and debounce system on starting of the electropumps (to avoid continuous false starts in the event of brief and limited user requests). CB2m: single-phase 230 V - 50 Hz with condenser and thermal overload protector built into the winding CB2: three-phase 230/400 V - 50 Hz up to 4 kW. 400/690 V - 50 Hz from 5.5 to 18.5 kW.
setswith twosingle-impeller centrifugal pumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
15
30
10
0
US g.p.m.
0
Imp. g.p.m.
0
45 30
20
40
45
Imp. g.p.m.
60
34 Prevalenza H (metri) 4
(feet)
120
CB2 - CP170M
90
CB2 - CP150
26
(feet)
30
22 60
18 1 pompa CP150
14
26
2 pompe CP150
1 pompa CP170M
22
80
2 pompe CP170M
18
10 30
14
6
40
10
2 0
50
25
0
3
0
10
75
100
125
6
Portata Q
150
175
30
35
70
0
105
140
175
5
210
10
US g.p.m.
0 0
20
245
315 l/min m3/h
US g.p.m.
60
40
15
280
15
4
Portata Q
Imp. g.p.m.
40
20
0
m3/h
12
4
10
225 l/min
200
9
30
20 10
0
30
Imp. g.p.m.
45
52
38 120
CB2 - CP158
(feet)
100
30 26
1 pompa CP158
22
(feet)
40 120
34
2 pompe CP158
80
1 pompa CP190
28
60
18
160
CB2 - CP190
46 Prevalenza H (metri) 4
34 Prevalenza H (metri) 4
US g.p.m.
75
50 30
38
30
Prevalenza H (metri) 4
25 15
2 pompe CP190 80
22 16
14 40
40
10
10 0
40
20
60
2
80 4
100 6
Portata Q
120
140 8
4
0
180 l/min
160
m3/h
10
60
30
90
120
5
0
150
180
210
240
m3/h
15
10
Portata Q
270 l/min
4
0 0
15
45
30
12
0
24
60 US g.p.m.
0
Imp. g.p.m.
0
48
36
42
50 30
75 45
60
US g.p.m. Imp. g.p.m.
70
CB2 - CP170
37
CB2 - CP200
(feet)
60
120
Prevalenza H (metri) 4
Prevalenza H (metri) 4
25 15
32
200 (feet)
50
27
90
22
1 pompa CP170
150
40 1 pompa CP200
30
2 pompe CP170
60
17
2 pompe CP200
100
20 50
12
10 30
7
0 0 0
26
52
78
3
104
130
156
182
9
6
Portata Q
4
208
234 l/min 15 m3/h
12
0
0
35
70
0
105
140
175 10
5
Portata Q
210
4
245 15
280
315 l/min m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - CPm 150 CB2 - CPm 158 CB2 - CPm 170 CB2 - CPm 170M CB2 - CPm 190 –––
POWER Three-phase CB2 - CP 150 CB2 - CP 158 CB2 - CP 170 CB2 - CP 170M CB2 - CP 190 CB2 - CP 200
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.75 + 0.75 0.75 + 0.75 1.1 + 1.1 1.1 + 1.1 1.5 + 1.5 2.2 + 2.2
1+1 1+1 1.5 + 1.5 1.5 + 1.5 2+2 3+3
14.4 10.8 14.4 19.2 16.8 18
240 180 240 320 280 300
29.5 36 41 36 50 58
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 1.5÷2.5 2÷3 2÷3 2÷3 3÷4 4÷5
1÷2 1.5÷2.5 1.5÷2.5 1.5÷2.5 2.5÷3.5 3.5÷4.5
setswith twosingle-impeller centrifugal pumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
50
100
150
50
0
100
200 150
US g.p.m.
0
Imp. g.p.m.
0
100 50
150
US g.p.m.
200
100
Imp. g.p.m.
150
51
35 110 (feet)
CB2 - CP220C
32
CB2 - CP220A
48
160
Prevalenza H (metri)
Prevalenza H (metri)
(feet)
45
29 90
140
42
26 23
1 pompa CP220C
20
39
2 pompe CP220C
70
1 pompa CP220A
36
2 pompe CP220A
120
33
17 50
14 0
100
200
300
400
500
20
10
0
600
30
Portata Q
0
50
100 50
0
700 40
100
200 10
0
300
400
500
20
600
30
Portata Q
150 100
0
m3/h
50
100
30
900 l/min
800
200 150
US g.p.m.
0
Imp. g.p.m.
0
40
120
37
50
100 50
700
800
40
150
m3/h
US g.p.m.
200
100
900 l/min
50
Imp. g.p.m. 180
150
55
(feet)
CB2 - CP220B
CB2 - CP220AH
52
Prevalenza H (metri)
Prevalenza H (metri)
(feet)
49
34
28
1 pompa CP220B
160
46
100
31
43
2 pompe CP220B
1 pompa CP220AH
40
25
80
140
2 pompe CP220AH
37
22 19
50
120
34 0 0
100
200 10
300
400
20
500 30
Portata Q
600
700 40
800
0
900 l/min m3/h
50
0
100
200 10
300
400
20
500 30
Portata Q
600
700 40
800 50
900 l/min m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Three-phase CB2 - CP 220C CB2 - CP 220B CB2 - CP 220A CB2 - CP 220AH
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
2.2 + 2.2 3+3 4+4 5.5 + 5.5
3+3 4+4 5.5 + 5.5 7.5 + 7.5
54 54 54 54
900 900 900 900
32 38 49 52
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 1.5÷2.5 2.5÷3.5 3÷4 3.5÷4.5
1÷2 2÷3 2.5÷3.5 3÷4
setswithtwosingle-impeller centrifugal pumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
30
60
90
US g.p.m.
0
30
60
90
US g.p.m.
0
25
50
75
Imp. g.p.m.
0
25
50
75
Imp. g.p.m.
45
35 (feet)
CB2 - CP25/160B
Prevalenza H (metri) 4
Prevalenza H (metri) 4
100
29 90
26 80
23
1 pompa CP25/160B
2 pompe CP25/160B
70
20
140
CB2 - CP25/160AR
40
32
(feet)
35 105
30 25
1 pompa CP25/160AR
20
2 pompe CP25/160AR
70
60
15
17 50
14
35
10 0
50
100
150
200
250
10
0
Portata Q
300
4
350
400
0
450 l/min m3/h
20
100
50
150 10
0
200
250
300
Portata Q
4
350
400
450 l/min m3/h
20
0
30
60
90
US g.p.m.
0
30
60
90
US g.p.m.
0
25
50
75
Imp. g.p.m.
0
25
50
75
Imp. g.p.m.
50
40
CB2 - CP25/160A
35
45
150 (feet)
Prevalenza H (metri) 4
(feet)
Prevalenza H (metri) 4
CB2 - CP25/200B
120
40
30 90
125
35
25 20
1 pompa CP25/160A
15
100
30
2 pompe CP25/160A
60
1 pompa CP25/200B
25
10
2 pompe CP25/200B 75
20
30
50
15
5 0
50
100
150
200
10
0
250
Portata Q
300
4
350
400
0
450 l/min m3/h
20
50
100
150
200
10
0
250
300
Portata Q
4
350 20
400
450 l/min m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - CPm 25/160B CB2 - CPm 25/160A ––– CB2 - CPm 25/200B
Three-phase CB2 -CP 25/160B CB2 - CP 25/160A CB2 - CP 25/160AR CB2 - CP 25/200B
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
1.1 + 1.1 1.5 + 1.5 2.2 + 2.2 2.2 + 2.2
1.5 + 1.5 2+2 3+3 3+3
24 26.4 26.4 26.4
400 440 440 440
33 38 42 49
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 1.5÷2.5 2÷3 2.5÷3.5 3.5÷4.5
1÷2 1.5÷2.5 2÷3 3÷4
setswithtwotwin-impellercentrifugalpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
15
30
10
0
45 30
20
40
US g.p.m.
0
Imp. g.p.m.
0
45
40
US g.p.m.
80
60
20
40
Imp. g.p.m.
60
70 140
CB2 - 2CP25/130N
40 35
(feet)
CB2 - 2CP25/160B
60
(feet)
Prevalenza H (metri) 4
Prevalenza H (metri) 4
20
200
50
105
30
150
40
25
30
70
20
1 pompa 2CP25/130N
15
20
2 pompe 2CP25/130N
35
25
50
75
100
3
0
0
150
6
Portata Q
15
175
200
40
50
0
0
m3/h
45 30
20
2 pompe 2CP25/160B
0
225 l/min
12
9
4
30
10
0
125
1 pompa 2CP25/160B
10
10 0
100
80
40
0
US g.p.m.
0
Imp. g.p.m.
0
55
120
160
5
200
10
Portata Q
20
40
240
4
280
US g.p.m.
80
40
m3/h
20
15
60
20
360 l/min
320
Imp. g.p.m.
60
70
CB2 - 2CP25/140H
50
170
Prevalenza H (metri) 4
Prevalenza H (metri) 4
45 140
40 35 110
30
1 pompa 2CP25/140H
25
2 pompe 2CP25/140H
(feet)
CB2 - 2CP25/160A
60
(feet)
200
50 150
40 30
100
20
1 pompa 2CP25/160A
2 pompe 2CP25/160A
50
10
80
20
0 0
25
50
75
100
150
6
3
0
125
0
20
225 l/min m /h
60
30
45
US g.p.m.
0 0
Prevalenza H (metri) 4
Prevalenza H (metri) 4
40 120
35 30 2 pompe 2CP25/140M
160
200
10
5
Portata Q
30
60
240
4
280
360 l/min
320
US g.p.m.
120
60
m3/h
20
15
90
30
Imp. g.p.m.
90
250
CB2 - 2CP32/200C
70
(feet)
1 pompa 2CP25/140M
120
80
160
CB2 - 2CP25/140M
25
80
40
0
Imp. g.p.m.
50 45
0
0
3
12
4
40
15
200
9
Portata Q
0
175
80
20
(feet)
200
60 50
150
40 30
1 pompa 2CP32/200C
100
2 pompe 2CP32/200C
20 50
15
50
0 0
30
60
90
120
150
180
210
10
5
Portata Q
4
240
10
270 l/min
0
m3/h
15
0
120
60 5
180
240
10
300
15
Portata Q
360 20
4
420 25
540 l/min
480 30
m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - 2CPm 25/130N CB2 - 2CPm 25/140H CB2 - 2CPm 25/140M CB2 - 2CPm 25/160B ––– –––
Three-phase CB2 - 2CP 25/130N CB2 - 2CP 25/140H CB2 - 2CP 25/140M CB2 - 2CP 25/160B CB2 - 2CP 25/160A CB2 - 2CP 32/200C
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.75 + 0.75 1.1 + 1.1 1.1 + 1.1 1.5 + 1.5 2.2 + 2.2 3+3
1+1 1.5 + 1.5 1.5 + 1.5 2+2 3+3 4+4
12 10.8 15 18 19.2 27.6
200 180 250 300 320 460
42 54 47 58 68 70
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 2÷3 3.5÷4.5 3÷4 3.5÷4.5 4÷5 4.5÷5.5
1.5÷2.5 3÷4 2.5÷3.5 3÷4 3.5÷4.5 4÷5
setswithtwotwin-impellercentrifugalpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min
90
Prevalenza H (metri) 4
Prevalenza H (metri) 4
CB2 - 2CP40/180C
CB2 - 2CP32/200B
80 70 60 50
1 pompa 2CP32/200B
40
2 pompe 2CP32/200B
1 pompa 2CP40/180C
2 pompe 2CP40/180C
30 20 0
60
120
180
240
300
Portata Q
360
420
480
540
4
Portata Q
80
100
CB2 - 2CP32/210B
CB2 - 2CP40/180B
70
Prevalenza H (metri) 4
Prevalenza H (metri) 4
90
60
80
50
70 60
1 pompa 2CP32/210B
50
40
2 pompe 2CP32/210B
1 pompa 2CP40/180B
30
2 pompe 2CP40/180B
20
40
10
30 0
60
120
180
240
300
Portata Q
360
420
480
0
540
100
200
300
4
400
500
600
Portata Q
120
700
800
900
4
90
CB2 - 2CP32/210A
100 90 80
1 pompa 2CP32/210A
70
CB2 - 2CP40/180A
80
Prevalenza H (metri) 4
110
Prevalenza H (metri) 4
4
2 pompe 2CP32/210A
60
70 60 50
1 pompa 2CP40/180A
40
2 pompe 2CP40/180A
30
50
20 0
60
120
180
240
300
Portata Q
360
420
480
540
0
100
200
300
4
400
500
600
Portata Q
700
800
900
4
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Three-phase CB2 - 2CP 32/200B CB2 - 2CP 32/210B CB2 - 2CP 32/210A CB2 - 2CP 40/180C CB2 - 2CP 40/180B CB2 - 2CP 40/180A
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
4+4 5.5 + 5.5 7.5 + 7.5 4.0 + 4.0 5.5 + 5.5 7.5 + 7.5
5.5 + 5.5 7.5 + 7.5 10 + 10 5.5 + 5.5 7.5 + 7.5 10 + 10
27.6 26.4 26.4 38.4 48 48
460 440 440 640 800 800
85 94 112 64 76 88
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 6÷7 7÷8 9÷10 4.5÷5.5 5÷6 6÷7
5.5÷6.5 6.5÷7.5 8.5÷9.5 4÷5 4.5÷5.5 5.5÷6.5
setswithtwomulti-impellerpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
10
20
30
10
0
US g.p.m.
0
Imp. g.p.m.
0
40
20
30
CB2 - 3CP80E
120 (feet)
30
40
20
US g.p.m. Imp. g.p.m.
30
30 90
24 60
18 12
1 pompa 3CP80E
2 pompe 3CP80E
180
CB2 - 4CP80E
48 Prevalenza H (metri) 4
Prevalenza H (metri) 4
36
(feet)
40 120
32 24 60
16
1 pompa 4CP80E
30
2 pompe 4CP80E
8
6
0
0
0
18
0
36
54
2
0
72 4
90
108
Portata Q
15
126
144
10
40
m3/h
36
18
0
54
2
72
90
108
4
US g.p.m.
0 0
15
126
4
30
162 l/min 10
60
45
30 15
144 8
6
Portata Q
Imp. g.p.m.
45 30
20
0
0
162 l/min
8
6
4
30
10
0
m3/h
US g.p.m. Imp. g.p.m.
45
160
49
42
CB2 - 3CP100E
120 (feet)
CB2 - 4CP100E
42 Prevalenza H (metri) 4
36 Prevalenza H (metri) 4
20 10
56
42
0
10
(feet) 120
35
30 90
28
24 60
18 12
1 pompa 3CP100E
8
14
2 pompe 3CP100E
7
0
50
75
3
100 6
125
Portata Q
150 9
4
175
200
40
0
0
225 l/min m3/h
12
2 pompe 4CP100E
0
0
25
1 pompa 4CP100E
30
0 0
80
21
56
28
84
112
4
0
140
168
8
Portata Q
196 12
4
224
252 l/min 16 m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - 3CPm 80E CB2 - 3CPm100E CB2 - 4CPm 80E CB2 - 4CPm100E
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.45 + 0.45 0.60 + 0.60 0.60 + 0.60 0.75 + 0.75
0.60 + 0.60 0.85 + 0.85 0.85 + 0.85 1+1
7.2 12 7.2 10.8
120 200 120 180
38 36 50 46
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 2÷3 2÷3 3÷4 3÷4
1.5÷2.5 1.5÷2.5 2.5÷3.5 2.5÷3.5
setswithtwomulti-impellerpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
10
20
30
10
0
40
20
30
US g.p.m.
0
Imp. g.p.m.
0
20
30
10
40
20
US g.p.m. Imp. g.p.m.
30
56
42
CB2 - 3CR80
120 (feet)
30 90
24 18
1 pompa 3CR80
60
2 pompe 3CR80
12
180
CB2 - 4CR80
48
Prevalenza H (metri) 4
36
Prevalenza H (metri) 4
10
(feet)
40 120
32 24
1 pompa 4CR80
16
2 pompe 4CR80
60
30
8
6 0
0
0
0
18
0
36
54
72
2
0
4
108
Portata Q
15
126
144 8
6
4
30
10
0
90
10
m3/h
18
0
36
54
2
72
90
108
4
144 8
6
Portata Q
126
4
162 l/min 10
m3/h
US g.p.m.
45 30
20
0
0
162 l/min
Imp. g.p.m.
40
42
CB2 - 3CR100
Prevalenza H (metri) 4
36
120 (feet)
30 90
24 60
18 12
1 pompa 3CR100
8
2 pompe 3CR100
30
0
0
0 0
25
50
75
3
100 6
125
Portata Q
150 9
4
175
200
225 l/min m3/h
12
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - 3CRm 80 CB2 - 3CRm 100 CB2 - 4CRm 80
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.45 + 0.45 0.60 + 0.60 0.60 + 0.60
0.60 + 0.60 0.85 + 0.85 0.85 + 0.85
7.2 12 7.2
120 200 120
38 36 50
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 2÷3 2÷3 3÷4
1.5÷2.5 1.5÷2.5 2.5÷3.5
setswithtwoself-primingpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
10
20 10
0
40
30 20
30
US g.p.m.
0
Imp. g.p.m.
0
49
160
Imp. g.p.m.
40
CB2 - JSW3BM
200 (feet)
Prevalenza H (metri) 4
120
Prevalenza H (metri) 4
US g.p.m.
45 30
60
(feet)
35
30 20
70
CB2 - JSW10M
42
15 10
50
28
150
40
80
21
1 pompa JSW10M
14
30
2 pompe JSW10M
1 pompa JSW3BM
20
40
100
2 pompe JSW3BM
50
7
10
0
0
0
40
20
60 4
2
0
0
80
10
120
6
Portata Q
20
4
140
160
40
20
30
0
180 l/min
US g.p.m.
0 0
75
100
3
125
150
6
Portata Q
15
175
m3/h
12
9
30
10
225 l/min
200
4
US g.p.m.
45 30
20
Imp. g.p.m.
40
240
CB2 - JSW3AM
68
(feet)
Prevalenza H (metri) 4
(feet)
Prevalenza H (metri) 4
50
76
180
CB2 - JSW12M
42
25
0
Imp. g.p.m.
56 49
0
0
m3/h
10
8
30
10
0
100
200
60
135
52
35 28
1 pompa JSW12M
21
2 pompe JSW12M
160
44
90
1 pompa JSW3AM
36
14
2 pompe JSW3AM
120
28
45
80
20
7 0
40
20
60
80 4
2
0
0
120
6
Portata Q
15
4
30
10
0
100
140
160
45 30
20
40
0
180 l/min m3/h
10
8
US g.p.m.
0
Imp. g.p.m.
0
56
50
75
100
3
125
6
Portata Q
20
40
150
175
m3/h
12
4
US g.p.m.
80
60
20
225 l/min
200
9
40
Imp. g.p.m.
60
70
180
CB2 - JSW3CM
48
25
0
(feet)
CB2 - JSW3AL
60
200
Prevalenza H (metri) 4
Prevalenza H (metri) 4
(feet) 135
40
50
32
150
40
90
24
1 pompa JSW3CM
16
30
2 pompe JSW3CM
1 pompa JSW3AL
20
45
100
2 pompe JSW3AL
50
8
10
0
0
0
0 0
25
50
75
100
3
125
6
Portata Q
150
175
9
4
200
m3/h
12
0
0
225 l/min
40
80
0
120
5
160
200
10
Portata Q
240
4
15
280
360 l/min
320 20
m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - JSWm 10M CB2 - JSWm 12M CB2 - JSWm 3CM CB2 - JSWm 3BM ––– –––
POWER Three-phase ––– ––– CB2 - JSW 3CM CB2 - JSW 3BM CB2 - JSW 3AM CB2 - JSW 3AL
MAXIMUM FLOW RATE*
kW
HP
0.75 + 0.75 0.90 + 0.90 1.1 + 1.1 1.5 + 1.5 2.2 + 2.2 2.2 + 2.2
1+1 1.25 + 1.25 1.5 + 1.5 2+2 3+3 3+3
m3/h 9.6 9.6 12 14.4 14.4 19.2
l/min 160 160 200 240 240 320
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
MAXIMUM HEAD metres 46 50 52 60 74 62
PRESSURE SWITCH SETTING -1-2bar bar 2÷3 1.5÷2.5 2.5÷3.5 2÷3 3÷4 2.5÷3.5 3.5÷4.5 3÷4 4÷5 3.5÷4.5 4÷5 3.5÷4.5
setswithtwoself-primingpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
10
20
30
10
0
20
40 30
US g.p.m.
0
Imp. g.p.m.
0
49
160
10
20
30
10
56
180
(feet)
Prevalenza H (metri) 4
Prevalenza H (metri) 4
CB2 - JCR12M
49
(feet) 120
35
Imp. g.p.m.
30
CB2 - JCR10M
42
US g.p.m.
40
20
42
28
135
35
80
21
1 pompa JCR10M
14
28
2 pompe JCR10M
1 pompa JCR12M
21
40
7
90
2 pompe JCR12M
14
0
0
0 0
40
20 2
60
80
100
4
6
Portata Q
120
4
140 8
7
180 l/min
160 10
45
0
m3/h
0
40
20
60
2
80 4
100 6
120
Portata Q
4
140 8
160 10
180 l/min m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - JCRm 10M CB2 - JCRm 12M
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.75 + 0.75 0.90 + 0.90
1+1 1.25 + 1.25
9.6 9.6
160 160
46 50
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar
2รท3 2.5รท3.5
1.5รท2.5 2รท3
setswith two single-impeller centrifugal pumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
50
100
150
50
0
200
100
150
US g.p.m.
0
Imp. g.p.m.
0
100 50
150
200
250
150
100
300
350 US g.p.m.
250
Imp. g.p.m.
200
50
50
CB2 - F32/200C
45
150
Prevalenza H (metri) 4
(feet)
Prevalenza H (metri) 4
CB2 - F40/200B
45
150
(feet)
40
40 125
35
1 pompa F32/200C
30
125
35
2 pompe F32/200C
100
1 pompa F40/200B
30
2 pompe F40/200B
100
25
25 75
75
20
20 50
15 0
200
100
10
0
300
400
500
600
30
20
Portata Q
0
50
700
0
m3/h
0
50
US g.p.m.
0
Imp. g.p.m.
0
250
150
200
55
300
150
450
15
600
750
30
900
45
CB2 - F32/200B
50
150
100 50
200
100
60
4 250
150
1350 l/min
1200
1050
m3/h
75
300
350 US g.p.m.
250
Imp. g.p.m.
200
60
180
50
50
15
900 l/min
Portata Q
200
100
800
40
4
150
100 50
0
(feet) 155
45
190
CB2 - F40/200A
55 Prevalenza H (metri) 4
Prevalenza H (metri) 4
50
(feet)
50
40
1 pompa F32/200B
35
45
130
2 pompe F32/200B
160
1 pompa F40/200A
40
105
30
2 pompe F40/200A 130
35
25
100
30
80
20
25 0
240
120
0
360
480
15
600
720
30
Portata Q
50
0
100 50
0
4
150
840
1080 l/min
0
m3/h
0
60
45
200
250
150
100
960
200
US g.p.m.
0
Imp. g.p.m.
0
150
300
450
15
600
30
200
750
900
45
Portata Q
400
150
300
1050
4 600
1350 l/min
1200
m3/h
75
60
US g.p.m.
800
450
750 Imp. g.p.m.
600
50
70
CB2 - F32/200A
60
200
CB2 - F50/200C
45 Prevalenza H (metri) 4
Prevalenza H (metri) 4
50 150
40
1 pompa F32/200A
30
2 pompe F32/200A
100
20
150 (feet)
(feet)
40 125
35
1 pompa F50/200C
30
2 pompe F50/200C
100
25 75
50
20
10
50
15
0 0 0
120
240
360
480 30
15
600
Portata Q
720
4
45
840
960
1080 l/min
0
m3/h
0
60
400
800 40
1200
1600
80
2000 120
Portata Q
2400
4
2800 160
3600 l/min
3200 200
m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Three-phase CB2 - F 32/200C CB2 - F 32/200B CB2 - F 32/200A CB2 - F 40/200B CB2 - F 40/200A CB2 - F 50/200C
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
4+4 5.5 + 5.5 7.5 + 7.5 5.5 + 5.5 7.5 + 7.5 11 + 11
5.5 + 5.5 7.5 + 7.5 10 + 10 7.5 + 7.5 10 + 10 15 + 15
54 60 60 84 84 204
900 1000 1000 1400 1400 3400
46 54 60 48 56 44
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 3÷4 3.5÷4.5 4.5÷5.5 3÷4 3.5÷4.5 3÷4
2.5÷3.5 3÷4 4÷5 2.5÷3.5 3÷4 2.5÷3.5
setswith two single-impeller centrifugal pumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
200
400
150
0
300
US g.p.m.
0
750 Imp. g.p.m.
0
800
600 450
600
55
(m)
CB2 - F50/200B
50
180
65
(feet)
(m)
100
300
200 100
200
CB2 - F50/250C
(feet)
Prevalenza H (metri) 4
Prevalenza H (metri) 4
155
Imp. g.p.m.
300
60
45
US g.p.m.
400
200
55
40
130
45
1 pompa F50/200B
30
50
105
0
1200
1600
80
40
2400
2000 120
Portata Q
0
200
400
150
0
450
600
US g.p.m.
0 0
400
200
0
750 Imp. g.p.m.
800
600
300
100
0
m3/h
200
160
4
125
30
3600 l/min
3200
2800
2 pompe F50/250C
35
20 800
1 pompa F50/250C
40
80
400
150
45
2 pompe F50/200B
25
0
175
600
800 40
20
100
1200
1000 60
Portata Q
200 200
400
500
300
1800 l/min m3/h
100
80
4
300
100
1600
1400
400
US g.p.m. Imp. g.p.m.
75
65
CB2 - F50/200A
200 (feet)
60
Prevalenza H (metri) 4
(m)
240 (feet)
CB2 - F50/250B
70 220
Prevalenza H (metri) 4
(m)
65
55 175
50
1 pompa F50/200A
45
200
60
2 pompe F50/200A
150
1 pompa F50/250B
55
2 pompe F50/250B
180
50
40 125
160
45
35
140
40
100
30 0
400
0
800
0
1200
1600
80
40
100
120
Portata Q
4
3600 l/min
3200
2800
400
200
300
0
m3/h
200
160
300
200 100
0
2400
2000
US g.p.m.
0
Imp. g.p.m.
0
56
Prevalenza H (metri) 4
Prevalenza H (metri) 4
135
40
1 pompa F50/250D
24
100
1200
50
Portata Q
200
100
1440
2 pompe F50/250D
90
16
2160 l/min 140 m3/h
100
4
300 200
1920
1680
75
400
500
300
400
US g.p.m. Imp. g.p.m.
45
290
CB2 - F50/250A
85
(feet)
32
960
(m)
CB2 - F50/250D
48
720
25
90
180
(m)
480
240
0
(feet)
80
260
75
1 pompa F50/250A
70
2 pompe F50/250A
230
65 200
60
8 0
55
0
0 0
200
400 20
600
800
1000
40
60
Portata Q
1200
4
1400 80
1600
1800 l/min
0
m3/h
0
100
240
480
720
25
960
1200
50
Portata Q
1440
1680
75
1920 100
4
2160 l/min 140 m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Three-phase CB2 - F 50/200B CB2 - F 50/200A CB2 - F 50/250D CB2 - F 50/250C CB2 - F 50/250B CB2 - F 50/250A
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
15 + 15 18.5 + 18.5 9.2 + 9.2 11 + 11 15 + 15 18.5 + 18.5
20 + 20 25 + 25 12.5 + 12.5 15 + 15 20 + 20 25 + 25
204 216 108 108 120 120
3400 3600 1800 1800 2000 2000
52 61 51 59 72 85
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 3.5÷4.5 4.5÷5.5 3.5÷4.5 4.5÷5.5 5.5÷6.5 7÷8
3÷4 4÷5 3÷4 4÷5 5÷6 6.5÷7.5
sets with two single-impeller centrifugal pumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
200
400
600
200
0
US g.p.m.
0
800 Imp. g.p.m.
0
800
400
600
50
400
200
600
1000 US g.p.m.
800
400
600
800
Imp. g.p.m.
55
CB2 - F65/200B
45
50
(feet)
40
1 pompa F65/200B
35
180
CB2 - F65/200A
150
2 pompe F65/200B
45
125
1 pompa F65/200A
40
100
30
(feet) 155
Prevalenza H (metri) 4
Prevalenza H (metri) 4
200
2 pompe F65/200A 130
45
25
105
30
75
20
25
15
20
50
0 0
420
840 50
1260
1680
2100
100
Portata Q
2520 150
4
2940
3360
80
3780 l/min
0
m3/h
0
200
440
880
1320
50
1760
2640
2200
100
Portata Q
3080
3520 200
150
4
3960 l/min 250
m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Three-phase CB2 - F 65/200B CB2 - F 65/200A
POWER
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
15 + 15 18.5 + 18.5
20 + 20 25 + 25
240 252
4000 4200
45 51
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 3รท4 3.5รท4.5
2.5รท3.5 3รท4
setswithtwoverticalmulti-impellerpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
10
20 10
0
40
30 20
30
US g.p.m.
0
Imp. g.p.m.
0
10
20
US g.p.m.
40
30
10
20
Imp. g.p.m.
30
95
70
300
CB2 - VL2/7
60
200
(feet)
Prevalenza H (metri) 4
(feet)
Prevalenza H (metri) 4
CB2 - VL2/15
85
250
75
50 150
65
40 30
1 pompa VL2/7
20
100
2 pompe VL2/7
200
55
1 pompa VL2/15
45
2 pompe VL2/15
150
50
35
10
100
0 0
25
0
40
20
60
80
100
4
2
0
120
6
Portata Q
0
10
20
4
20
0
180 l/min
160
m3/h
10
40 30
US g.p.m.
0
Imp. g.p.m.
0
80
40
60
80
100
4
2
70
20
4
180 m3/h
10
US g.p.m.
40
30 20
10
160
8
Imp. g.p.m.
30
450
CB2 - VL2/18
120
(feet) 360
Prevalenza H (metri) 4
(feet)
60
10
140
120
6
140
260
CB2 - VL2/11
Prevalenza H (metri) 4
20
0
Portata Q
30
10
0
140 8
100
195
270
80
50 40
1 pompa VL2/11
30
60
130
2 pompe VL2/11
1 pompa VL2/18
40
2 pompe VL2/18
180
90
20 10 0 0
20
40 2
60
80 4
100 6
Portata Q
140
120
4
8
160
180 l/min
65
20
0
0
m3/h
10
0
0 0
40
20 2
60
80 4
100 6
Portata Q
120
4
140 8
160 10
180 l/min m3/h
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - VLm 2/7 CB2 - VLm 2/11 CB2 - VLm 2/15 CB2 - VLm 2/18
POWER Three-phase CB2 - VL 2/7 CB2 - VL 2/11 CB2 - VL 2/15 CB2 - VL 2/18
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.75 + 0.75 1.1 + 1.1 1.5 + 1.5 1.8 + 1.8
1+1 1.5 + 1.5 2+2 2.5 + 2.5
7.8 7.8 7.2 7.2
130 130 120 120
60 75 90 105
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 3.5÷4.5 5÷6 6.5÷7.5 7÷8
3÷4 4.5÷5.5 6÷7 6.5÷7.5
setswithtwoverticalmulti-impellerpumps CURVES AND PERFORMANCE DATA AT n= 2900 1/min 0
15
30
10
0
US g.p.m.
0
Imp. g.p.m.
0
45 30
20
40
56
15
30
10
US g.p.m.
45 30
20
Imp. g.p.m.
40
100
(m)
CB2 - VL4/7
48
(m)
160
40
300 (feet)
Prevalenza H (metri) 4
(feet)
Prevalenza H (metri) 4
CB2 - VL4/18
90 80
120
32
250
70
24
1 pompa VL4/7
16
80
2 pompe VL4/7
60
1 pompa VL4/18
50
200
2 pompe VL4/18
150
40
8
40
20
0
30 0
25
50
75
100
0
Portata Q
15
4
175
9
30
10
0
150
6
3
0
125
200
225 l/min m3/h
12
40
50
25
US g.p.m.
0 0
75
100
125
150
6
3
0
Imp. g.p.m.
45 30
20
100
0
Portata Q
15
9
200
m3/h
US g.p.m.
45 30
20
225 l/min
12
4
30
10
175
Imp. g.p.m.
40
140
70
(m)
(m)
CB2 - VL4/11
60
200
400 (feet)
Prevalenza H (metri) 4
(feet)
Prevalenza H (metri) 4
CB2 - VL4/22
120 100
50 150
300
80
40 30
1 pompa VL4/11
20
60
100
2 pompe VL4/11
1 pompa VL4/22
40
50
200
2 pompe VL4/22
100
20
10 0
0
0
0
25
50
75
100
0
Portata Q
15
4
175
9
30
10
0
150
6
3
0
125
200
m3/h
12
50
25
75
3
0
100
125
150
6
175
9
Portata Q
4
200 12
225 l/min 3
m /h
US g.p.m.
45 30
20
0
0
225 l/min
Imp. g.p.m.
40
80
250
(m)
CB2 - VL4/15
70 Prevalenza H (metri) 4
(feet) 200
60 50
1 pompa VL4/15
40
2 pompe VL4/15
150
100
30 20
50
10 0 0
25
50
75
100 6
3
125
Portata Q
150 9
4
175
200
225 l/min m3/h
12
Tolerance of the performance curves according to EN ISO 9906 App. A.
TYPE Single-phase CB2 - VLm 4/7 CB2 - VLm 4/11 CB2 - VLm 4/15 CB2 - VLm 4/18 –––
POWER Three-phase CB2 - VL 4/7 CB2 - VL 4/11 CB2 - VL 4/15 CB2 - VL 4/18 CB2 - VL 4/22
MAXIMUM FLOW RATE*
kW
HP
m3/h
l/min
MAXIMUM HEAD metres
0.75 + 0.75 1.1 + 1.1 1.5 + 1.5 1.8 + 1.8 2.2 + 2.2
1+1 1.5 + 1.5 2+2 2.5 + 2.5 3+3
13.2 13.2 12 10.8 10.8
220 220 200 180 180
50 60 75 90 105
* Indicates the maximum flow rate of the two pumps, for the minimum setting pressure of the pressure switch - 2 -
PRESSURE SWITCH SETTING -1-2bar bar 2.5÷3.5 3.5÷4.5 4.5÷5.5 6÷7 7÷8
2÷3 3÷4 4÷5 5.5÷6.5 6.5÷7.5
DIMENSIONSANDWEIGHTS g g d DN2
d
c
DN2
c
DN1
e
e
f
f
DN1
h
h a
a
b
CB2 - CP
b
CB2 - 2CP
g
DN2
d
e
f
c
DN1
h
a
b
CB2 - 3-4CP TYPE Single-phase Three-phase CB2 - CPm 150 CB2 - CP 150 CB2 - CPm 158 CB2 - CP 158 CB2 - CPm 170 CB2 - CP 170 CB2 - CPm 170M CB2 - CP 170M CB2 - CPm 190 CB2 - CP 190 ––– CB2 - CP 200 ––– CB2 - CP 220C ––– CB2 - CP 220B ––– CB2 - CP 220A ––– CB2 - CP 220AH CB2 - CPm 25/160B CB2 - CP 25/160B CB2 - CPm 25/160A CB2 - CP 25/160A ––– CB2 - CP 25/160AR CB2 - CPm 25/200B CB2 - CP 25/200B CB2 - 2CPm 25/130N CB2 - 2CP 25/130N CB2 - 2CPm 25/140H CB2 - 2CP 25/140H CB2 - 2CPm 25/140M CB2 - 2CP 25/140M CB2 - 2CPm 25/160B CB2 - 2CP 25/160B ––– CB2 - 2CP 25/160A ––– CB2 - 2CP 32/200C ––– CB2 - 2CP 32/200B ––– CB2 - 2CP 32/210B ––– CB2 - 2CP 32/210A ––– CB2 - 2CP 40/180C ––– CB2 - 2CP 40/180B ––– CB2 - 2CP 40/180A CB2 - 3CPm 80E ––– CB2 - 3CPm 100E ––– CB2 - 4CPm 80E ––– CB2 - 4CPm 100E –––
INLETS DN1
DN2
11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 100 100 100 100 100 2" 2" 2" 2" 2" 11/2" 2" 2" 2" 2" 2" 3" 3" 3" 3" 3" 4" 100 4" 4" 11/2" 11/2" 11/2" 11/2" 11/2"
11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 80 80 80 80 80 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 11/2" 1 11/2" 1/2" 11/2" 11/2" 2" 2" 2" 2" 2" 3" 80 3" 3" 11/2" 11/2" 11/2" 11/2" 11/2"
a 520 520 520 615 615 615 615 615 700 700 700 700 700 615 615 615 615 615 520 615 615 615 615 615 700 700 700 700 700 700 700 520 520 520 520 520
b 560 560 560 625 625 625 625 625 1000 1000 1000 1000 1000 645 645 645 645 645 600 595 596 670 625 910 910 910 920 920 920 980 980 980 600 596 595 670
c 620 620 620 630 630 630 630 630 780 780 780 780 780 630 630 630 680 620 630 630 630 630 630 780 780 780 895 895 895 780 780 780 620 630 630 630
DIMENSIONS mm d e 255 160 160 255 255 160 280 190 280 280 190 190 300 190 300 300 190 430 220 430 220 430 220 430 220 430 220 320 180 320 180 320 180 320 180 350 200 300 155 330 170 170 350 170 340 190 385 130 400 200 400 400 200 200 430 200 430 430 200 420 210 420 420 210 420 210 300 155 350 170 170 330 170 340 190
kg f 450 450 450 480 480 480 520 520 520 650 650 650 650 650 480 480 480 480 530 420 455 445 495 490 600 600 600 590 590 590 610 610 610 420 445 455 495
g 500 500 500 500 500 500 500 700 700 700 700 700 500 500 500 500 500 500 500 500 500 700 700 700 700 700 700 700 700 500 500 500 500 500
h 305 305 305 370 370 370 370 370 560 560 560 560 560 370 370 370 370 370 305 370 370 370 370 370 565 565 565 565 565 565 565 565 305 305 305 305 305
1~ 45.0 45.0 65.0 65.0 77.0 70.0 70.0 85.5 51.0 67.5 67.5 77.5 51.0 67.5 67.5 77.5
3~ 43.8 45.5 64.3 64.3 76.0 80.0 173.0 175.0 181.0 181.0 69.0 69.0 70.0 83.0 50.5 67.0 67.0 77.0 80.0 119.0 125.0 156.0 163.0 175.0 185.0 195.0 -
DIMENSIONS AND WEIGHTS
g
g
d DN2
d
DN2
DN1
e
e
f
f
c
c
DN1
h
a
h
a b
b
CB2 - JSW
CB2 - 3-4CR
g g d DN2
d
DN1
c
DN2
e
e
f
f
c
DN1
h
a
h a
b
CB2 - F
CB2 - JCR
TYPE Single-phase Three-phase CB2 - 3CRm 80 ––– CB2 - 3CRm100 ––– CB2 - 4CRm 80 ––– CB2 - JSWm 10M ––– CB2 - JSWm 12M ––– CB2 - JSWm 3CM CB2 - JSW 3CM CB2 - JSWm 3BM CB2 - JSW 3BM ––– CB2 - JSW 3AM ––– CB2 - JSW 3AL CB2 - JCRm 10M ––– CB2 - JCRm 12M ––– ––– CB2 - F 32/200C ––– CB2 - F 32/200B ––– CB2 - F 32/200A ––– CB2 - F 40/200B ––– CB2 - F 40/200A ––– CB2 - F 50/200C ––– CB2 - F 50/200B ––– CB2 - F 50/200A ––– CB2 - F 50/250D ––– CB2 - F 50/250C ––– CB2 - F 50/250B ––– CB2 - F 50/250A ––– CB2 - F 65/200B ––– CB2 - F 65/200A
b
INLETS DN1
DN2
11/2" 11/2" 1/2" 11/2" 11/2" 11/2" 2" 2" 2" 2" 2" 1/2" 111/2 " 11/2" 4" 4" 100 4" 4" 4" 125 125 125 125 125 125 125 150 150 150
11/2" 11/2" 1/2" 11/2" 11/2" 11/2" 11/2" 1/2" 111/2 " 11/2" 11/2" 1/2" 111/2 " 11/2" 3" 3" 80 3" 3" 3" 100 100 100 100 100 100 100 125 125 125
a 520 520 520 520 520 520 520 520 520 520 520 520 700 700 700 700 700 800 800 800 800 800 800 800 800 800 800
b 600 596 595 630 630 630 710 710 710 710 710 700 700 700 910 910 910 920 920 920 1200 1200 1200 1200 1200 1200 1200 1300 1300 1300
c 620 630 630 630 620 620 620 620 620 620 620 620 620 780 780 780 895 780 895 1330 1330 1330 1330 1330 1330 1330 1330 1330
DIMENSIONS mm d e 300 155 350 170 170 330 170 340 220 220 340 340 220 400 230 400 230 400 230 400 230 400 230 350 210 210 350 350 210 440 230 440 230 440 230 440 230 440 230 450 310 450 310 450 310 450 330 450 330 330 450 330 450 330 520 320 520 320 520 320
kg f 420 445 455 400 400 400 425 425 425 425 425 420 420 420 660 660 660 660 660 725 725 725 770 770 770 770 770 800 800 800
g 500 500 500 500 500 500 500 500 500 500 500 500 700 700 700 700 700 700 800 800 800 800 800 800 800 800 780 780 780
h 305 305 305 305 305 305 305 305 305 305 305 565 565 565 565 565 700 700 700 700 700 700 700 700 700
1~ 51.0 67.5 67.5 48.0 48.0 78.5 78.5 41.0 41.0 -
3~ 76.5 76.5 78.5 78.5 161.0 173.0 181.0 182.0 189.0 383.0 415.0 440.0 398.0 408.0 442.0 468.0 455.0 475.0
DIMENSIONSANDWEIGHTS
g d
f
c
DN2
e
DN1
h a b
CB2 - VL
TYPE Single-phase CB2 - VLm 2/7 CB2 - VLm 2/11 CB2 - VLm 2/15 CB2 - VLm 2/18 CB2 - VLm 4/7 CB2 - VLm 4/11 CB2 - VLm 4/15 CB2 - VLm 4/18 –––
INLETS Three-phase CB2 - VL 2/7 CB2 - VL 2/11 CB2 - VL 2/15 CB2 - VL 2/18 CB2 - VL 4/7 CB2 - VL 4/11 CB2 - VL 4/15 CB2 - VL 4/18 CB2 - VL 4/22
DN1
DN2
2" 2" 2" 2" 2" 2" 2" 2" 2"
2" 2" 2" 2" 2" 2" 2" 2" 2"
a 615 615 615 615 615 615 615 615 615
b 700 700 700 700 700 700 700 700 700 700
c 835 908 938 1000 835 880 880 880 938 1000
DIMENSIONS mm d e 500 130 500 140 500 140 500 140 500 500 130 500 140 500 140 140 500 140 500 140
kg f 765 838 868 943 765 810 810 810 868 943
g 350 350 350 350 350 350 350 350 350 350
h 370 370 370 370 370 370 370 370 370 370
1~ 65.3 76.0 78.0 80.0 65.3 75.0 77.0 79.0 -
3~ 63.8 71.0 74.0 76.0 63.8 70.0 73.0 75.0 87.0
asynchronous single-phase electric motors
Asynchronous single-phase electric motors made using the best materials in order to obtain a product of superior quality as regards sturdiness and low consumption.
RATED POWERS AT 50 Hz 0.25 ÷ 2.2 kW (0.33 ÷ 3 HP) 2 pole 0.37 ÷ 1.5 kW (0.50 ÷ 2 HP) 4 pole LIMITS OF USE Rated voltage ± 5% Environment temperature up to +40 °C Altitude up to 1000 metres a.s.l.
● ● ● ● ●
EXECUTION AND SAFETY STANDARDS:
● ●
EN 60034-1 IEC 34-1 CEI 2-3
CE I 1110
GUARANTEE YEARSsubject accordingto to our general terms terms of sale. of sale. GUARANTEE 12YEAR our general
● ● ● ●
wire; the heads are accurately tied and shaped by pressing. Impregnation is carried out in a continuous cycle with the "PREHEATING - IMMERSION - BAKING" system using class F polyester resin. In this way a perfect insulation and filling is realised which improves the transmission of heat towards the outside. MOTOR CASING: aluminium SHIELDS: die-cast aluminium. SHIELD: fan side in technopolymer for motor H 56. FAN: in glass-charged thermoplastic material. ROTOR: die-cast, dynamically balanced, with protected bearings, greased for life. TERMINAL BOX: with cable clamp. CONDENSER: permanent, to standards VDE-IMQ. INSULATION: class F. DEGREE OF PROTECTION: IP 44 according to IEC 34-5 BALANCING: according to degree N of standard IEC 34-14. PAINTING: the surface protection of the motor is obtained thanks to a cycle comprising pickling, phosphatizing, passivation, first coat and second finishing coat with paint deposited with an electrostatic process and oven-hardened Km 1: single-phase 230 V - 50 Hz.
CONSTRUCTIONCHARACTERISTICS ●
-
-
MOTOR: The asynchronous single-phase motors of the Km1 series are of closed type, with external ventilation and with permanent condenser, suitable for continuous duty. the motor casing is made of die-cast aluminium. At the top it is equipped with a housing for the condenser and a base for connection to the electric power supply . the stator pack is made of magnetic sheet metal with a low loss figure. the stator windings, automatically made, use class H double insulated
EXECUTIONSONREQUEST
⇒ protection IP 55 ⇒ different voltages ⇒ motors for frequency
60 Hz
TECHNICALCHARACTERISTICS TYPE
Rated power
kW
HP
Revs
Rated current
Condenser capacity
Power factor
Yield
Static torque
Static current
1/min
A
µF
cos ϕ
1.8 2.75 3.0 4.2 5.2 7.5 9.7 9.6 16.0
8 12.5 10 20 25 35 45 45 50
3.1 4.5 5.5 7.8 10.8
14 20 25 31.5 40
J
WEIGHT
η
Rated torque
Rated current
kgm2
kg
0.90 0.90 0.83 0.86 0.93 0.90 0.93 0.93 0.83
63% 67% 65% 66% 68% 72% 74% 74% 76%
0.70 0.70 0.72 0.70 0.71 0.77 0.70 0.72 0.70
2.5 3.1 3.4 3.0 3.2 3.3 3.5 3.6 3.6
0.00020 0.00035 0.00045 0.00053 0.00058 0.00120 0.00140 0.00130 0.00260
3.35 4.6 6.8 8.0 8.0 11.6 12.6 15.7 17.2
0.91 0.93 0.95 0.98 0.95
62% 62% 65% 67% 70%
0.75 0.78 0.73 0.72 0.75
2.6 2.6 2.7 2.6 2.8
0.00073 0.00220 0.00280 0.00370 0.00490
7.8 9.8 11.5 14.0 17.0
2 POLE SINGLE-PHASE - 230 V - 50 Hz Km1 - 56 A/2 Km1 - 63 B/2 Km1 - 71 A/2 Km1 - 71 B/2 Km1 - 71 C/2 Km1 - 80 B/2 Km1 - 80 C/2 Km1 - 90 S/2 Km1 - 90 LB/2
0.25 0.37 0.37 0.55 0.75 1.1 1.5 1.5 2.2
0.33 0.50 0.50 0.75 1 1.5 2 2 3
2730 2730 2800 2800 2800 2800 2800 2850 2840
4 POLE SINGLE-PHASE - 230 V - 50 Hz Km1 - 71 B/4 Km1 - 80 A/4 Km1 - 80 B/4 Km1 - 90 S/4 Km1 - 90 LA/4
0.37 0.55 0.75 1.1 1.5
0.50 0.75 1 1.5 2
1380 1400 1400 1420 1420
DIMENSIONS CONSTRUCTION SHAPE B3 (IM 1001)
CONSTRUCTION SHAPE B5 (IM 3001)
l
l
e
e
ha
h
p n d
d
hd
z
he
m
f
ga
bc
k b bb
t
a ab
la
f
ga
c
s
aa ba
CONSTRUCTION SHAPE B14 (IM 3601) l e
he
C E Italian Electrical I 1110 C o m m i t t e e
m1
p1 n1 d
Authorisation n° prot. 1064 / 27.3.87
s1
t1
ga
F
TYPE
2 Pole Km1-56 A/2 Km1-63 B/2 Km1-71 A/2 Km1-71 B/2 Km1-71 C/2 ––– Km1-80 B/2 Km1-80 C/2 Km1-90 S/2 ––– Km1-90 LB/2
4 Pole a aa ab b ba bb bc ––– 90 20 110 71 20 90 10.5 ––– 100 22 120 80 23.5 98 9 ––– 112 23 134 90 24.5 110 10 Km1-71 B/4 112 23 134 90 24.5 110 10 ––– 112 23 134 90 24.5 110 10 Km1-80 A/4 125 27.5 152 100 32 124 12 Km1-80 B/4 125 27.5 152 100 32 124 12 ––– 125 27.5 152 100 32 124 12 Km1-90 S/4 140 30 170 100 32.5 125 12.5 Km1-90 LA/4 140 30 170 125 32.5 150 12.5 ––– 140 30 170 125 32.5 150 12.5
DIMENSIONS mm c
d
e
f
ga
h
ha
hd
he
k
36
9
20
3
10.2
56
8
121
65
14 181
l
la
m
m1
n
n1
p1
s
s1
t
t1
z
8
100
65
80
50 120 80
p
7
M5
3
2.5
45
M5
3
2.5 49.5
40
11
23
4
12.5
63
8
152
91
7
209
9
115
75
95
60 140 90
9
45
14
30
5
16
71
8
162.5 91.5
7
243
9
130
85
110
70 160 105
9.5
M6 3.5 2.5
61
45
14
30
5
16
71
8
162.5 91.5
7
243
9
130
85
110
70 160 105
9.5
M6 3.5 2.5
61
45
14
30
5
16
71
8
162.5 91.5
7
243
9
130
85
110
70 160 105
9.5
M6 3.5 2.5
61
50
19
40
6
21.5
80
10 202.5 122.5
9
279 10.5 165 100 130
80 200 120 11.5 M6 3.5
3
69
50
19
40
6
21.5
80
10 202.5 122.5
9
279 10.5 165 100 130
80 200 120 11.5 M6 3.5
3
69
60
19
40
6
21.5
80
10 202.5 122.5
9
299 10.5 165 100 130
80 200 120 11.5 M6 3.5
3
69
56
24
50
8
27
90
10 218.5 128.5
9
297 10
165 115 130
95 200 140 11.5 M8 3.5
3
75
56
24
50
8
27
90
10 218.5 128.5
9
322 10
165 115 130
95 200 140 11.5 M8 3.5
3
75
56
24
50
8
27
90
10 218.5 128.5
9
322 10
165 115 130
95 200 140 11.5 M8 3.5
3
75
SPHERICAL TANK TYPE
FITTING
CAPACITY
24 SF
1"
24 litres
FITTING
CAPACITY
1" 1" 1" 11/2" 11/2"
20 litres
Maximum working pressure 8 bar. Interchangeable diaphragm in butyl rubber.
CYLINDRICAL TANKS TYPE 24 CL 60 CL 100 CL 200 CL 300 CL
60 litres 100 litres 200 litres 300 litres
Maximum working pressure 10 bar. Interchangeable diaphragm in butyl rubber.
VERTICAL TANKS TYPE 8 VT 18 VT 60 VT 100 VT 200 VT 300 VT 500 VT Maximum working pressure 10 bar. Interchangeable diaphragm in butyl rubber.
SPHERICAL KIT TYPE KS 24 24 litre spherical tank pressure gauge 0 ÷ 6 bar 5-way fitting - 1" gas pressure switch “SQUARE D” Maximum working pressure 8 bar. Interchangeable diaphragm in butyl rubber.
FITTING
1" 1" 1" 1" 11/2" 11/2" 11/2"
CAPACITY 8 litres 18 litres 60 litres 100 litres 200 litres 300 litres 500 litries
CYLINDRICAL KIT TYPE KC 24
TYPE KC 60
20 litre cylindrical tank
60 litre cylindrical tank
pressure gauge 0 ÷ 6 bar
pressure gauge 0 ÷ 6 bar
5-way fitting - 1" gas
5-way fitting - 1" gas
pressure switch “SQUARE D”
pressure switch “SQUARE D”
hose 1" gas (600 mm)
hose 1" gas (600 mm)
Maximum working pressure 10 bar. Interchangeable diaphragm in butyl rubber.
AUTOMATIC AIR FEEDERS TYPE
TANK CAPACITY
AIRFLO 1
100 ÷ 500 litres
AIRFLO 2
600 ÷ 1000 litres
Automatic air feeders suitable for maintianing the air cushion in the autoclave tanks (without diaphragm).
3-WAY NIPPLE FOR AIR FEEDERS TYPE
FITTING
DOUBLE CENTRAL FITTING
NA 1.00
1" x 1"
1/2"
x 1/4" (male/female)
NA 1.25
11/4" x 11/4"
1/2"
x 1/4" (male/female)
NA 1.50
11/2" x 11/2"
1/2"
x 1/4" (male/female)
NA 2.00
2" x 2"
1/2"
x 1/4" (male/female)
3-way brass fittings for connections with air feeders (AIRFLO)
PRESSURE SWITCHES TYPE
MANUFACTURER
STANDARD SETTING*
FSG2
SQUARE D
1.4 ÷ 2.8 bar
FYG 22
SQUARE D
5.4 ÷ 7.0 bar
FYG 32
SQUARE D
8 ÷ 10.5 bar
PM/5
ITALTECNICA
1.4 ÷ 2.8 bar
PM/5 SK(1)
ITALTECNICA
1.4 ÷ 2.8 bar
* Adjustable (1) Approved pressure switch
PRESSURE GAUGES TYPE MC 6 MR 6 MR 10
FITTING
DIAMETER
SCALE
1/4" - central
50 mm
0 ÷ 6 bar
1/4" - radial
63 mm
0 ÷ 6 bar
1/4" - radial
63 mm
0 ÷10 bar
PRESSURE GAUGES IN A GLYCERIN BATH TYPE MCG 6 MRG 6 MRG 10
FITTING
DIAMETER
SCALE
1/4" - central
50 mm
0 ÷ 6 bar
1/4" - radial
63 mm
0 ÷ 6 bar
1/4" - radial
63 mm
0 ÷10 bar
3 - 5 WAY FITTINGS TYPE
FITTING
R 3 - 3 way
1"
R 5 - 5 way
1"
R 3: three-way fittings in moulded brass with 1" gas.connections R 5: five-way fittings in moulded brass with 1" gas and 1/4" gas connections.
HOSES TYPE TF 5 TF 6 TF 10
PIPE
FITTINGS
LENGTH
1"
1" X 1"
500 mm
1"
1" X 1"
600 mm
1"
1" X 1"
1000 mm
Hoses with 1" gas male/female fittings, in non-toxic EPDM rubber reinforced on the outside with blue spiral galvanised steel wire for cold water. Maximum working pressure 10 bar.
HOSES COMPLETE WITH ELBOW TYPE TFG 5 TFG 6
PIPE
FITTINGS
LENGTH
3/4"
1" X 1"
500 mm
1"
1" X 1"
600 mm
Hoses with 1" gas male/female fittings, in non-toxic EPDM rubber reinforced on the outside with blue spiral galvanised steel wire for cold water. Maximum working pressure 10 bar.
*ELECTRONIC PRESSURE REGULATORS execution TYPE EKO EASYPRESS
approved
VOLT
Hz
CURRENT
FITTINGS
FLOW RATE
230 ±10%
50/60
max 6 A
1” x 1”
8 m3/h
The pressure generated by the pump must be minimum 2.5 bar and maximum 10 bar. The column of water between the appliance and the highest user must not exceed 6 metres. Liquid temperature up to +60°C. Protection IP 65.
TYPE EASYPRESS
VOLT
Hz
CURRENT
FITTINGS
FLOW RATE
230 ±10%
50/60
max 8 A
1” x 1”
10 m3/h
The pressure generated by the pump must be minimum 3 bar and maximum 10 bar. The column of water between the appliance and the highest user must not exceed 15 metres. Liquid temperature up to +65°C. Protection IP 65.
TYPE MAXI EASYPRESS
VOLT
Hz
CURRENT
FITTINGS
FLOW RATE
230 ±10%
50/60
max 16 A
11/4” x 11/4”
12 m3/h
The pressure generated by the pump must be minimum 3 bar and maximum 10 bar. The column of water between the appliance and the highest user must not exceed 15 metres. Liquid temperature up to +65°C. Protection IP 65.
TYPE EASYPRESS VARIO
VOLT
Hz
CURRENT
FITTINGS
FLOW RATE
230 ±10%
50/60
max 16 A
11/4” x 11/4”
12 m3/h
Electronic device with possibility of manually regulating the system pressure from 3 to 6.5 bar (complete with pressure gauge), For the system pressure regulated at 3 bar the pressure generated by the pump must be minimum 4.5 bar and maximum 12 bar and the column of water between the appliance and the highest user must not exceed 6 metres; for the system pressure regulated at 6.5 bar the pressure generated by the pump must be minimum 8 bar and maximum12 bar and the column of water between the appliance and the highest user must not exceed 45 metres. Liquid temperature up to +65°C. Protection IP 65.
*Electronic devices for starting (when the tap is turned on) and stopping (when the tap is turned off) single-phase electropumps; they regulate the water flow rate and pressure, keeping them constant. In the event of lack of water, they ensure automatic stopping of the pump.
FLOATS
(APPROVED V.D.E.- I.M.Q.)
TYPE 0315/3 0315/5 0315/10 With H07 RN-F cable: With PVC cable:
T 80/3 T 80/5 T 80/10
With PVC cable:
H07 RN-F or PVC
3 metres
H07 RN-F or PVC
5 metres
H07 RN-F or PVC
10 metres
CABLE
LENGTH
H07 RN-F or PVC
3 metres
H07 RN-F or PVC
5 metres
H07 RN-F or PVC
10 metres
floats with simple function (emptying), with double watertight protection chamber, with 10 A switch. floats with dual function (emptying and filling). Double watertight protection chamber, with 10 A switch.
TYPE SMALL 3 SMALL 5 With H07 RN-F cable: With PVC cable:
LENGTH
floats with simple function (emptying), with 10 A switch. floats with dual function (emptying and filling), with 10 A switch.
TYPE
With H07 RN-F cable:
CABLE
CABLE
LENGTH
H07 RN-F or PVC
3 metres
H07 RN-F or PVC
5 metres
floats with simple function (emptying), with simple protection, with 20 A switch. floats with dual function (emptying and filling). With simple protection, with 20 A switch.
FLOATS WITH SOCKET TYPE 0315 SI/3 0315 SI/5 0315 SI/10
(APPROVED V.D.E.- I.M.Q.) CABLE
LENGTH
H07 RN-F
3 metres
H07 RN-F
5 metres
H07 RN-F
10 metres
CABLE
LENGTH
H07 RN-F
3 metres
Floats with emptying function, with 10 A switch.
TYPE T 80 SI/3 T 80 SI/5 T 80 SI/10
H07 RN-F
5 metres
H07 RN-F
10 metres
Floats with emptying function, with double watertight protection chamber, with 10 A switch.
TYPE SMALL SI/3 SMALL SI/5 SMALL SI/10
CABLE
LENGTH
H07 RN-F
3 metres
H07 RN-F
5 metres
H07 RN-F
10 metres
Floats with emptying function, with simple protection, with 20 A switch.
FOOT VALVES TYPE VF 0.5 VF 0.75 VF 1 VF 1.25 VF 1.5 VF 2
FITTINGS 1/2" 3/4"
1" 11/4" 11/2" 2"
Brass foot valves, stainless steel suction filter.
CHECK VALVES TYPE VR 0.5 VR 0.75 VR 1 VR 1.25 VR 1.5 VR 2
FITTINGS 1/2" 3/4"
1" 11/4" 11/2" 2"
Brass check valves.
BALL CHECK VALVES WITH THREADED FITTINGS TYPE VR-FT 1.25 VR-FT 1.5 VR-FT 2
FITTINGS
11/4" 11/2" 2"
Check valves for submersible pumps (solid-laden waste waters).
BALL CHECK VALVES WITH FLANGED FITTINGS TYPE VR-FF DN 65 VR-FF DN 80 Check valves for submersible pumps (solid-laden waste waters).
FITTINGS Ø 65 mm Ø 80 mm
FILTER HOLDERS WITH PLASTIC HEAD TYPE MEDIUM MEDIUM JUNIOR JUNIOR SENIOR SENIOR -
CARTRIDGE HEIGHT
THREADED FITTINGS
5"
3/4"
F 0.75 F1 F 0.75 F1 F 0.75 F1
5"
1"
7"
3/4"
7"
1"
10"
3/4"
10"
1"
Maximum working pressure 10 bar (at temp. +20째C) Maximum temperature + 50째C (at pressure 3 bar). - Filter holder for RL, FA, HA and LA cartridges.
FILTER HOLDERS WITH BRASS HEAD AND AIR VENT TYPE MEDIUM MEDIUM JUNIOR JUNIOR SENIOR SENIOR -
CARTRIDGE HEIGHT
THREADED FITTINGS
5"
3/4"
K 0.75 K1 K 0.75 K1 K 1.5 K2
5"
1"
7"
3/4"
7" 10"
1" 11/2" 2"
CARTRIDGE HEIGHT
CARTRIDGE MATERIAL
10"
polypropylene
10"
Maximum working pressure 10 bar (at temp. +20째C) Maximum temperature + 50째C (at pressure 3 bar). - Filter holder for RL and FA cartridges.
MOBILE FILTER TYPE DEPURAL 10
Head in ABS for use with foodstuffs. Cup in AS for use with foodstuffs. It is suitable for connection by means of a hose to any tap in order to supply filtered water, free from impurities.
WRENCHES FOR FILTER HOLDERS TYPE WRENCH F WRENCH K WRENCH DEPURAL Suitable for fitting and removing the cartridge from the filter holder.
FILTER HOLDER F K DEPURAL 10
POLYESTER FILTER CARTRIDGES TYPE
FILTRATION
HEIGHT
RL 5
50 µ
5"
RL 7
50 µ
7"
RL 10
50 µ
10"
Cartridge suitable for filter holders type F - K.
POLYPROPYLENE FILTER CARTRIDGES TYPE
FILTRATION
HEIGHT
FA 5
50 µ
5"
FA 7
50 µ
7"
FA 10
50 µ
10"
Cartridge suitable for filter holders type F - K - DEPURAL 10.
FILTER CARTRIDGE WITH POLYPHOSPHATE CRYSTALS TYPE HA 10
HEIGHT 10”
Cartridge suitable for filter holders type F.
FILTER CARTRIDGE WITH ACTIVATED CARBON TYPE LA 10 Cartridge suitable for filter holders type F.
HEIGHT 10”
FLAT PVC HOSE TYPE
FITTING
LENGTHS
TP 1.25
11/4"
5 - 10 - 20 metres
TP 1.50
11/2"
5 - 10 - 20 metres
TP 2.00
2"
5 - 10 - 20 metres
TP 2.50
21/2"
5 - 10 - 20 metres
TP 3.00
3"
5 - 10 - 20 metres
Plasticized flat delivery hose, complete with PVC hosetail, resistant to abrasions and to atmospheric agents. Indicated for irrigation even with fertilisers and for draining water in combination with DRAINAGE ELECTROPUMPS.
SUCTION HOSE TYPE GARDEN KIT
FITTING
LENGTH
1"
7 metres
Hose, complete with foot valve. RECOMMENDED FOR PORTABLE GARDEN ELECTROPUMPS, BETTY TYPE
MECHANICAL LITRE COUNTER TYPE
MAXIMUM FLOW RATE
MAXIMUM PRESSURE
FITTINGS
MT 1
80 l/min
3.5 bar
1" x 1"
Mechanical litre counter for private use, suitable for measuring diesel fuel. RECOMMENDED FOR USE WITH TYPE CK PUMPS
SPRAY GUN WITH HOSE TYPE NZ 0.75 NZ 1.00
ELBOW FITTING 3/4"
1"
Aluminium spray gun complete with hose, reinforced with steel spiral , 4 metres long, with threaded fittings. RECOMMENDED FOR USE WITH TYPE CK PUMPS
STRAIGHT HOSETAIL FITTINGS TYPE RP 0.75 RP 1 RP 1.25 RP 1.5 RP 2
Ø HOSETAIL
THREADED FITTING
25 mm
3/4"
30 mm
50 mm
1" 11/4" 11/2" 2"
Ø HOSETAIL
THREADED FITTING
RPG 0.75
25 mm
3/4"
RPG 1
30 mm
1"
RPG 1.25
35 mm
11/4"
RPG 1.5
40 mm
11/2"
RPG 2
50 mm
2"
35 mm 40 mm
Nylon fittings.
CURVED HOSETAIL FITTINGS TYPE
Nylon fittings.
TEFLON FOR HYDRAULIC JOINS TYPE
LENGTH
TFN 1
12 metres
TFN 2
50 metres
SPRAY CAN TYPE SPRAY 1
COLOUR
CAPACITY
pedrollo blue
400 ml
CONDENSERS FOR SURFACE ELECTROPUMPS
type F= FASTON
TYPE 06 F 10 F 12 F 14 F 16 F 16 F 20 F 20 F 25 F 25 F 30 F 30 F 31 F 40 F 45 F 50 F 55 F 60 F 70 F 80 F 80 F
CAPACITY
VOLTAGE
FREQUENCY
6.3 µF
450 V
50 ÷ 60 Hz
10 µF
450 V
50 ÷ 60 Hz
12.5 µF
450 V
50 ÷ 60 Hz
14 µF
450 V
50 ÷ 60 Hz
16 µF
450 V
50 ÷ 60 Hz
16 µF
250 V
50 ÷ 60 Hz
20 µF
450 V
50 ÷ 60 Hz
20 µF
250 V
50 ÷ 60 Hz
25 µF
450 V
50 ÷ 60 Hz
25 µF
250 V
50 ÷ 60 Hz
30 µF
450 V
50 ÷ 60 Hz
30 µF
250 V
50 ÷ 60 Hz
31.5 µF
450 V
50 ÷ 60 Hz
40 µF
450 V
50 ÷ 60 Hz
45 µF
450 V
50 ÷ 60 Hz
50 µF
450 V
50 ÷ 60 Hz
55 µF
450 V
50 ÷ 60 Hz
60 µF
450 V
50 ÷ 60 Hz
70 µF
450 V
50 ÷ 60 Hz
80 µF
450 V
50 ÷ 60 Hz
80 µF
250 V
50 ÷ 60 Hz
- Condensers with CE marking and VDE-IMQ approval.
CONDENSERS FOR SUBMERGED AND SUBMERSIBLE ELECTROPUMPS
type C= OUTGOING CABLES
TYPE 08 C 10 C 12 C 14 C 16 C 20 C 25 C 30 C 30 C 31 C 35 C 40 C 45 C 50 C 60 C 75 C 80 C
CAPACITY
VOLTAGE
FREQUENCY
8 µF
450 V
50 ÷ 60 Hz
10 µF
450 V
50 ÷ 60 Hz
12.5 µF
450 V
50 ÷ 60 Hz
14 µF
450 V
50 ÷ 60 Hz
16 µF
450 V
50 ÷ 60 Hz
20 µF
450 V
50 ÷ 60 Hz
25 µF
450 V
50 ÷ 60 Hz
30 µF
450 V
50 ÷ 60 Hz
30 µF
250 V
50 ÷ 60 Hz
31.5 µF
450 V
50 ÷ 60 Hz
35 µF
450 V
50 ÷ 60 Hz
40 µF
450 V
50 ÷ 60 Hz
45 µF
450 V
50 ÷ 60 Hz
50 µF
450 V
50 ÷ 60 Hz
60 µF
250 V
50 ÷ 60 Hz
75 µF
450 V
50 ÷ 60 Hz
80 µF
250 V
50 ÷ 60 Hz
- Condensers with CE marking and VDE-IMQ approval
BEARINGS TYPE
INTERNAL PLAY
6201 ZZ 6201 ZZ 6202 ZZ 6203 6203 ZZ 6203 ZZ 6203 2RS 6204 ZZ 6204 ZZ 6205 ZZ 6206 ZZ 6304 ZZ 6304 ZZ 6304 2RS 6306 ZZ 6307 ZZ 6308 ZZ 6310 ZZ 7203 B 7303 B
DIMENSIONS
Normal
12 x 32 x 10 mm
C3 (increased)
12 x 32 x 10 mm
Normal
15 x 35 x 11 mm
Normal
17 x 40 x 12 mm
Normal
17 x 40 x 12 mm
C3 (increased)
17 x 40 x 12 mm
Normal
17 x 40 x 12 mm
Normal
20 x 47 x 14 mm
C3 (increased)
20 x 47 x 14 mm
Normal
25 x 52 x 15 mm
C3 (increased)
30 x 62 x 16 mm
Normal
20 x 52 x 15 mm
C3 (increased)
20 x 52 x 15 mm
Normal
20 x 52 x 15 mm
C3 (increased)
30 x 72 x 19 mm
C3 (increased)
35 x 80 x 21 mm
C3 (increased)
40 x 90 x 23 mm
C3 (increased)
40 x 90 x 23 mm
Normal
17 x 40 x 12 mm
Normal
17 x 47 x 14 mm
SEALS FOR SURFACE ELECTROPUMPS TYPE
AR
FN
PNL
RN
AR 12 AR 13 AR 14 PNL 12 FN 14 FN 18 FN 18 NU (Dimensions DIN 24960) FN 20 FN 24 FN 32 NU (Dimensions DIN 24960) FN 38
MATERIALS Rotating ring
Elastomer
Spring
Ceramica
Grafite
NBR
AISI 304
Ceramica
Grafite
NBR
Ceramica
Grafite
NBR
AISI 304 AISI 304 AISI 304
Ceramica
Grafite
NBR
AISI 304
Ceramica
Grafite
NBR
AISI 316
Ceramic
Graphite
NBR
AISI 316
Ceramica
Grafite
NBR
AISI 316
Ceramica
Grafite
NBR
AISI 316
Ceramica
Grafite
NBR
AISI 316
Ceramica
Grafite
NBR
AISI 316
Ceramica
Grafite
NBR
AISI 316
MATERIALS Fixed ring
FN DV
Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø
12 mm 13 mm 14 mm 12 mm 14 mm 18 mm 18 mm 20 mm 24 mm 32 mm 38 mm
SEALS FOR SUBMERGED AND SUBMERSIBLE ELECTROPUMPS TYPE
MG
SHAFT
Fixed ring
AR 12/R AR 13/R PNL 16 FN 20 DV RN 15/17 MG1S1/14 MG1S2/14 Special mechanical seals on request.
Rotating ring
SHAFT
Elastomer
Spring AISI 304 AISI 304 AISI 304
Ceramica
Graphite
NBR
Ceramic
Carburundum
NBR
Ceramica
Graphite
NBR
Widia
Carburundum
NBR
AISI 316 AISI 316 AISI 316
Graphite
AISI 431
NBR
AISI 431
Carburundum
Carburundum
NBR
Ceramic
Graphite
NBR
AISI 316 AISI 316 AISI 316
Ø Ø Ø Ø Ø Ø Ø
12 13 16 20 17 14 14
mm mm mm mm mm mm mm
CABLE FOR LEVEL PROBES TYPE
SECTION
CSL
1.5 mm
2
WEIGHT PER METRE 0.019 kg
CABLES FOR SUBMERGED ELECTROPUMPS TYPE 4x1 4 x 1.5 4 x 2.5 4x4 4x6 4 x 10 4 x 16
WEIGHT PER METRE 2
mm H07 RN-F
0,165 kg
mm2 H07 RN-F
0,205 kg
mm2 H07 RN-F
0,290 kg
mm2 H07 RN-F
0,420 kg
mm2 H07 RN-F
0,505 kg
mm2 H07 RN-F
1,030 kg
mm2 H07 RN-F
2,050 kg
“3M” RESIN JUNCTION KIT FOR ELECTRIC CABLES TYPE RPS 1 RPS 2 RPS 3 RPS 4 RPS 5 RPS 6
N° LEADS
CABLE SECTION
Ø EXT. JUNCTION
4
1 ÷ 2.5 mm2
Ø 32 mm
4
1 ÷ 10 mm2
Ø 42 mm
4
4 ÷ 16 mm2
Ø 48 mm
4
14 ÷ 25 mm2
Ø 60 mm
4
16 ÷ 35 mm2
Ø 65 mm
4
35 ÷ 95 mm2
Ø 80 mm
“3M” HEAT-SHRINKING JUNCTION KIT FOR ELECTRIC CABLES TYPE
N° LEADS
GPS 1 GPS 2 GPS 3 GPS 4 GPS 5 GPS 6
4
1 ÷ 2.5 mm2
4
4 ÷ 6
CABLE SECTION
mm2
4
10 mm2
4
16 mm2
4
25 mm2
4
35 mm2
CABLES WITH PLUG FOR SINGLE-PHASE SURFACE ELECTROPUMPS TYPE H05 VV-F (PVC) H07 RN-F (NEOPRENE)
CABLE SECTION 2
3 x 0.75 mm 2
3 x 1 mm
LENGTH
PLUG
150 cm
Schuko
150 cm
Schuko
FANS TYPE
DIMENSIONS
SHAFT DIAMETER
14VN05
85 x 18 mm
12 mm
14VN06
104 x 21 mm
12 mm
14VN07
125 x 24 mm
14.5 mm
14VN08
138 x 27 mm
20 mm
14VN08L
138 x 27 mm
20 mm
14VN09
162 x 32 mm
24 mm
14VN10
176 x 38 mm
28 mm
14VN1062
155 x 37 mm
28 mm
14VN13
165 x 45 mm
36 mm
FOR 4” SINGLE-PHASE SUBMERGED ELECTROPUMPS TYPE
MOTOR POWER kW HP
QEM 033 QEM 050 QEM 075 QEM 100 QEM 150 QEM 200 QEM 300
0.25 0.37 0.55 0.75 1.1 1.5 2.2
0.33 0.50 0.75 1 1.5 2 3
CONDENSER µF
RATED CURRENT
12.5 16 20 30 40 50 75
3.5 4.5 6 7 11 13 18
A A A A A A A
- Single-phase 220 ÷ 230V 50 Hz The control panel is supplied on a box made of self-extinguishing thermoplastic material; it protects the electropump against overloads and short circuits and may be connected to a float (or a pressure switch, etc.). COMPONENTS: • Isolating switch with fuses • Start-stop selector • Terminal board for connecting the electropump and the float (or the pressure switch, etc.) • Thermal protection with manual reset • Green warning light that indicates when the electropump is running• Condenser For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
FOR 4” AND 6” THREE-PHASE SUBMERGED ELECTROPUMPS TYPE QET QET QET QET QET QET QET QET QET QET QET QET QET QET QET QET QET
MOTOR POWER kW HP
050 075 100 150 200 300 400 550 750 1000 1250 1500 1750 2000 2500 3000 4000
0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9.2 11 13 15 18.5
0.50 0.75 1 1.5 2 3 4 5.5 7.5 10 12.5 15 17.5 20 25
RATED CURRENT 1.7 2 2.5 3.9 4.8 7 9 11.5 15.5 21.5 23.5 27.5 31.5 36 45
A A A A A A A A A A A A A A A
22
30
54 A
30
40
68 A
- Three-phase 380 ÷ 415V 50 Hz The control panel is supplied on a box made of self-extinguishing thermoplastic material; it protects the electropump against overloads and short circuits and has a selector for manual or automatic operation (with float, pressure switch, etc.). COMPONENTS: • Isolating switch with fuses • Selector for manual or automatic operation • Three-pole contactor • Adjustable three-pole thermal relay with manual reset • Terminal board for connecting the electropump and the float (or the pressure switch, etc.) • Green warning light that indicates when the electropump is running For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
FOR 4” SINGLE-PHASE ELECTROPUMPS WITH LEVEL PROBES TYPE QSM QSM QSM QSM QSM QSM QSM
MOTOR CURRENT kW HP
033 050 075 100 150 200 300
CONDENSER µF
0.25 0.37 0.55 0.75 1.1 1.5
0.33 0.50 0.75 1 1.5 2
12.5 16 20 30 40 50
2.2
3
75
RATED CURRENT 3.5 4.5 6 7 11 13
A A A A A A
17.5 A
- Single-phase 220 ÷ 230V 50 Hz The control panel is supplied on a box made of self-extinguishing thermoplastic material; it protects the electropump against overloads and short circuits. It has a selector for manual or automatic operation (with float, pressure swich, etc.) and may be connected to level probes that protect the pump against dry operation.
Level probes
COMPONENTS: • Isolating switch with fuses • Selector for manual or automatic operation • Three-pole contactor • Thermal protection with manual reset • Condensatore • Terminal board for connecting the electropump, the float (or the pressure switch, etc.) and the level probes • Green warning light that indicates when the electropump is running • Red warning light that indicates tripping of the thermal relay • Level probes (the CSL type cables for connection of the probes are excluded) For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
FOR 4” AND 6” THREE-PHASE ELECTROPUMPS WITH LEVEL PROBES TYPE
Level probes
QST QST QST QST QST QST QST QST QST QST QST QST QST QST QST QST
MOTOR POWER kW HP
050 075 100 150 200 300 400 550 750 1000 1250 1500 1750 2000 2500 3000
0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9.2 11 13 15 18.5 22
0.50 0.75 1 1.5 2 3 4 5.5 7.5 10 12.5 15 17.5 20 25 30
RATED CURRENT 1.7 2 2.5 3.9 4.8 7 9 11.5 15.5 21.5 23.5 27.5 31.5 36 45 54
A A A A A A A A A A A A A A A A
- Three-phase 380 ÷ 415V 50 Hz The control panel is supplied on a box made of self-extinguishing thermoplastic material; it protects the electropump against overloads and short circuits . It has a selector for manual or automatic operation (with float, pressure swich, etc.) and may be connected to level probes that protect the pump against dry operation. COMPONENTS: • Isolating switch with fuses • Selector for manual or automatic operation • Three-pole contactor • Adjustable three-pole thermal relay with manual reset • Terminal board for connecting the electropump, the float (or the pressure switch, etc.) and the level probes • Green warning light that indicates when the electropump is running • Red warning light that indicates tripping of the thermal relay • Level probes (the CSL type cables for connection of the probes are excluded) For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
FOR 4” AND 6” SUBMERGED ELECTROPUMPS TYPE
ADJUSTABLE POWER kW HP
(ADJUSTABLE POWER)*
VOLTAGE
RATED CURRENT
EVOLUTION MONO
from 0.37to2.2from 0.5 to 3
single-phase
from 2 to 16 A
EVOLUTION TRI/1
from 0.55to7.5from 0.75to10
three-phase
from 2 to 15 A
EVOLUTION TRI/2
from 7.5 to10from 10 to15
three-phase
from16 to24 A
- Single-phase 220 ÷ 230V 50 Hz - Three-phase 380 ÷ 415V 50 Hz The control panel is supplied on a box made of IP55 self-extinguishing thermoplastic material and contains an electronic card that allows you to regulate the current of intervention of the protection against overloads and short circuits and controls the cosϕ value to avoid dry operation of the electropump without the aid of level probes. It may be connected to a float (or a pressure switch, etc.). COMPONENTS: • Isolating switch with fuses • Start-stop selector with door blocking device • Electronic card with trimmer for regulating the protections • Three-pole contactor (only in the three-phase versions) • Terminal board for connecting the electropump • Terminals for connecting the float (or the pressure switch, etc.) • External panel with warning led. N.B. For single-phase models, the condenser is excluded and is applied according to the power of the pump. For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
FOR SINGLE -PHASE DRAINAGE ELECTROPUMPS TYPE
MOTOR POWER kW HP
QES 300 MONO
2.2
CONDENSER µF
3
60
RATED CURRENT 16 A
- Single-phase 220 ÷ 230V 50 Hz The control panel is supplied on a box made of IP55 self-extinguishing thermoplastic material; it protects the electropump against overloads and short circuits. It may be connected to the thermal protector built into the winding of the drainage pumps VXCm30, PVXCm30, MCm30, PMCm30. COMPONENTS: • Isolating switch with fuses • Start-stop selector • Three-pole contactor • Adjustable three-pole thermal relay with manual reset • Condenser • Terminal board for connecting the electropump • Terminals for connecting the thermal protector built into the winding of the electropump• Green warning light that indicates when the pump is running• Red warning light that indicates tripping of the thermal relay . COMPONENTS ON REQUEST: • Terminals for connecting the auxiliary alarm level float • Red warning light that indicates when the alarm level has been exceeded • power supply termilnals (220÷230V / 50Hz) of the remote alarm device (lamp, siren etc.). For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
FOR THREE-PHASE DRAINAGE ELECTROPUMPS TYPE
MOTOR POWER kW HP
QES 150 QES 200 QES 300
1.1 1.5 2.2
1.5 2 3
RATED CURRENT 4.2 A 5.2 A 6.5 A
- Three-phase 380 ÷ 415V 50 Hz The control panel is supplied on a box made of self-extinguishing thermoplastic material; it protects the electropump against overloads and short circuits. It has a selector for manual or automatic operation (with float) and may be connected to the thermal protector built into the winding of the drainage pumps VXC, PVXC, MC, PMC. COMPONENTS: • Isolating switch with fuses • Selector for manual or automatic operation • Three-pole contactor • Adjustable three-pole thermal relay with manual reset • Terminal board for connecting the electropump • Terminals for connecting the thermal protector built into the winding of the drainage pumps VXC, PVXC, MC, PMC • Terminals for connecting the float • Green warning light that indicates when the pump is running For a correct choice of control panel, ensure that the current absorbed by the pump corresponds to the values in the table.
EXAMPLESOFINSTALLATION
12
10
9 8
5
5
7
11
7 8 4
6 6 4 STATIC LEVEL
DYNAMIC LEVEL
2
2
3
1
1
min 1 metre
1) 2) 3) 4) 5) 6)
4SR submerged electropump Clamps for securing the power cable Level control probes against dry operation Anchorage of the electropump support cables to the cover of the borehole Pressure gauge Non return valve
min 1 metre
7) 8) 9) 10) 11) 12)
Flow rate regulating gate valve Electric power cable Control panel with level probes Autoclave Pressure switch Electrovalve/electrocompressor
4SR electropumps may be installed in boreholes with a diameter not less than 4" (100 mm). The submerged electropump is lowered into the borehole by means of the delivery pipe to such a depth as to guarantee its complete immersion (min. 50 cm and at least one metre from the bottom of the borehole) even during operation, when a lowering of the level of liquid in the borehole may occur. When the submerged electropump is installed in a borehole, it is recommended to secure it with a stainless steel or nylon cable, connected to the holes provided on the delivery body
.
PEDROLLO MOTORS
4PD PEDROLLO 4” SUBMERGED ELECTRIC MOTORS - 1~ P2
230 V / 50 Hz 4PDm / 0.50 4PDm / 0.75 4PDm / 1 4PDm / 1.5 4PDm / 2
kW
HP
0.37 0.55 0.75 1.1 1.5
0.50 0.75 1 1.5 2
Axial
load
Revs
Rated current
Starting current
Power factor
Yield
N
1500
1500 2500 2500 2500
1/min
A
A
η
cos ϕ
Rated torque
2810 2820 2840 2840 2850
3.1 4.2 6.4 8.3 10.8
8.5 14.5 20.5 27 34
64% 66% 68% 70% 71%
0.85 0.86 0.84 0.85 0.85
0.70 0.75 0.79 0.78 0.76
PEDROLLO 4” SUBMERGED ELECTRIC MOTORS TYPE
Rated power
Three-phase
P2
400 V / 50 Hz 4PD / 0.50 4PD / 0.75 4PD / 1 4PD / 1.5 4PD / 2 4PD / 3 4PD / 4 4PD / 5.5 4PD / 7.5 4PD / 10
kW
HP
0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5
0.50 0.75 1 1.5 2 3 4 5.5 7.5 10
Starting Condenser t o r q u e (Vc=450V)
Axial
load
h
Weight
µF
mm
kg
16 20 31.5 40 55
294 319 344 404 454
6.8 8.0 9.1 11.5 13.7
h
Weight
38
Rated power
- 3~ -
Revs
Rated current
Starting current
Yield
Power factor
Starting torque
1/min
A
A
η
cos ϕ
Rated torque
mm
kg
1500 1500 1500 1500 2500 2500 2500 2500 2500
2815 2815 2820 2835 2830 2840 2830
1.2 1.7 2.1 2.9 4.1 5.6 7.4
4.5 6.4 8 12 16.5 23 35.2
67% 69% 70% 73% 75% 76% 77%
0.68 0.69 0.74 0.75 0.75 0.75 0.76
2.20 2.00 2.30 2.60 2.80 3.10 3.20
294 294 319 344 404 454 560
6.8 6.8 8.0 9.1 11.5 13.7 16.1
4500 4500 4500 4500
2840 2830 2840
9.9 12.9 18.2
45 62 94.3
79% 79% 80%
0.75 0.76 0.75
2.44 2.10 2.73
660 745 850
21.5 25.0 30.0
N
h
TYPE
Single-phase
Ø 96
PEDROLLO rewindable submerged motors in an oil bath, suitable for food uses, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 1.5 metres (2.5 metres for powers higher than 3 kW) submersible type, certified for drinking water. LIMITS OF USE: Water temperature: up to +30 °C Starts/hour: 25 at regular intervals Cooling: water flow rate not less than 5 cm/s
73
6PD TYPE
Rated power
400 V / 50 Hz 6PD / 5.5 6PD / 7.5 6PD / 10 6PD / 12.5 6PD / 15 6PD / 17.5 6PD / 20 6PD / 25 6PD / 30 6PD / 40 6PD / 50
Axial
load
Revs
P2
Three-phase
Rated current
Starting current
N
kW
HP
4 5.5 7.5 9.2 11 13 15 18.5 22 30 37
5.5 7.5 10 12.5 15 17.5 20 25 30 40 50
10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 20000 20000 20000
- 3~ Yield
Power factor
Starting torque
mm
kg
599 629 659 689 719 754 784 844 904 1029 1189
36.0 38.0 41.0 44.0 47.0 49.0 51.0 55.0 61.0 82.0 98.0
1/min
A
A
η
cos ϕ
Rated torque
2830 2840 2850 2830 2840 2820 2825 2870 2810 2820 2840
9 12.5 16 19.2 22.9 27 31.1 37.8 43.9 62.7 74.4
41.6 64 83 104 127 146 168 227 260 388 418
79% 80% 81% 82% 82% 83% 83% 84% 85% 85% 86%
0.82 0.82 0.84 0.85 0.85 0.84 0.84 0.83 0.85 0.82 0.84
1.8 2 2 2.3 2.2 2.1 2.1 2.4 2.5 2.7 2.4
h
Weight
h
PEDROLLO 6” SUBMERGED ELECTRIC MOTORS
PEDROLLO rewindable submerged motors in an oil bath, suitable for food uses, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 4 metres long, submersible type, certified for drinking water. LIMITS OF USE: Water temperature: up to +30 °C Starts/hour: 20 at regular intervals Cooling: water flow rate not less than 16 cm/s
Ø 143
FRANKLIN ELECTRIC® MOTORS
4FK Rated power
P2
230 V / 50 Hz 4FKm / 0.50 4FKm / 0.75 4FKm / 1 4FKm / 1.5 4FKm / 2
Axial
load
Revs
Rated current
Starting current
Power factor
Yield
1/min
A
A
η
cos ϕ
Rated torque
2860 2855 2855 2855 2825
3.4 4.3 5.7 8.6 10.6
11.2 15.9 21.1 31.8 35
53% 63% 60% 62% 66%
0.93 0.94 0.98 0.94 0.95
0.84 0.76 0.89 0.84 0.73
N
kW
HP
0.37 0.55 0.75 1.1 1.5
0.50 0.75 1 1.5 2
1500 1500 1500 1500 3000 3000 3000
FRANKLIN E. 4” SUBMERGED ELECTRIC MOTORS TYPE
Rated power
Three-phase
P2
400 V / 50 Hz 4FK / 0.50 4FK / 0.75 4FK / 1 4FK / 1.5 4FK / 2 4FK / 3 4FK / 4 4FK / 5.5 4FK / 7.5 4FK / 10
Starting Condenser t o r q u e (Vc=450V)
HP
0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5
0.50 0.75 1 1.5 2 3 4 5.5 7.5 10
Weight
µF
mm
kg
16 20 31.5 40 55
242 271 299 327 356
8.7 10.0 11.4 12.7 14.0
h
Weight
- 3~ -
Revs
Rated current
Starting current
Yield
Power factor
Starting torque
1/min
A
A
η
cos ϕ
Rated torque
mm
kg
1500 1500 1500 2500 2500 2500 2500
2815 2815 2820 2835 2830 2840
1.1 1.6 2.1 3 4 5.9
4.8 6.4 9.3 14.4 19.2 28.9
66% 67% 69% 73% 73% 75%
0.70 0.75 0.75 0.76 0.76 0.75
2.1 1.9 2.1 2.8 2.5 3.1
223 242 271 299 327 356
7.4 8.3 9.5 10.9 12.1 13.5
2500 4500 4500
2830 2840 2830 2840
7.8 10 13.7 18.4
41.3 58 75.4 101.2
76% 78% 76% 74%
0.75 0.78 0.79 0.79
3.2 3.4 2.8 3.6
423 584 698 774
16.5 24.1 29.4 33.0
Axial
load
N
kW
h
4500
h
TYPE
Single-phase
- 1~ -
38
FRANKLIN E. 4” SUBMERGED ELECTRIC MOTORS
Ø 95.5
FRANKLIN ELECTRIC resin-impregnated submerged motors, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 1.5 metres (2.5 metres for powers higher than 3 kW) submersible type, certified for drinking water. LIMITS OF USE: Water temperature: maximum 30 °C Starts/hour: 20 at regular intervals Cooling: water flow rate not less than 8 cm/s
73
6FK TYPE
Rated power
Three-phase
P2
400 V / 50 Hz 6FK / 5.5 6FK / 7.5 6FK / 10 6FK / 12.5 6FK / 15 6FK / 20 6FK / 25 6FK / 30 6FK / 40 6FK / 50 6FK / 60
Axial
load
Revs
Rated current
Starting current
- 3~ -
Yield
Power factor
Starting torque
mm
kg
582 615 647 679 712 777 842 907 1037 1405 1558
37.5 41.1 45.2 47.5 50.9 56.7 63.3 69.3 83.9 135.0 148.0
N
kW
HP
4 5.5 7.5 9.2 11 15 18.5 22 30 37 44
5.5 7.5 10 12.5 15 20 25 30 40 50 60
15500 15500 15500 15500 15500 15500 15500 15500 15500 27500 27500 27500 27500
1/min
A
A
η
cos ϕ
Rated torque
2860 2870 2860 2870 2860 2860 2850 2860 2860 2880 2870
9.3 12.5 16 20.7 23.3 31.3 38.5 45.3 63.5 73 93.9
43 64 83 112 129 169 231 268 393 410 514
78% 79% 79% 81% 81% 81% 82% 83% 83% 84.5% 86%
0.82 0.82 0.86 0.80 0.85 0.85 0.85 0.86 0.84 0.87 0.84
1.6 1.9 1.9 2.2 2.1 2.1 2.5 2.4 2.6 2.3 2.2
h
Weight
h
FRANKLIN E. 6” SUBMERGED ELECTRIC MOTORS
FRANKLIN ELECTRIC resin-impregnated submerged motors, 50 Hz (n=2900 1/min) Insulation: class F. - Protection: IP 68. Power cable: 4 metres long, submersible type, certified for drinking water. LIMITS OF USE: Water temperature: maximum 30 °C Starts/hour: 20 at regular intervals Cooling: water flow rate not less than 16 cm/s
Ø 137
electropumpswithelectronicpressureregulator
Smallelectropumpscompletewithelectronicdeviceforstarting andstoppingthepump,onturningthetaponandoff.Itregulates theflowrateandpressure,keepingthemconstant. In the event of lack of water it ensures that the pump stops .
DIMENSIONSmm
POWER
TYPE
229 61
HP
0.37 0.50 0.60 0.75 1.1 0.37 0.50 0.60 0.75 0.75 0.75 1.1 1.1 0.75 1.1 1.1 0.37 0.45 0.60 0.60 0.75 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.45 0.60 0.60 0.75
0.50 0.70 0.85 1 1.5 0.50 0.70 0.85 1 1 1 1.5 1.5 1 1.5 1.5 0.50 0.60 0.85 0.85 1 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.60 0.85 0.85 1
60
110
Power on Pump on Failure Restart 230V~
G1”
50-60 Hz
37047 San Bonifacio (Verona) ITALY Tel. +39 045 6136311 Fax +39 045 7614663 - 045 7612253 www.pedrollo.com
EASYPRESS
®
Max 65 ºC Max 1 MPa (10 bar) Max 16 (8) A Max 1.5 kW
Weight1.1 kg
Typicalinstallation
COMPONENTS - Single-phase electropump 230V - 50Hz - EASYPRESS - 1.5 metre cable with Schuko plug
*For correct operation of the EASYPRESS device, the height of the column of water must not exceed 15 metres.
*maximum height approx.. 15 metres
PKm 60 - EP PKm 65 - EP PKm 70 - EP PKm 80 - EP PKm 100 - EP PKSm 60 - EP PKSm 65 - EP PKSm 70 - EP PKSm 80 - EP CPm 150 - EP CPm 158 - EP CPm 170 - EP CPm 170M -EP 2CPm 25/130N - EP 2CPm 25/140H - EP 2CPm 25/140M - EP 2CPm 80E - EP 3CPm 80E - EP 4CPm 80E - EP 3CPm 100E - EP 4CPm 100E - EP JSWm 1C - EP JSWm 1B - EP JSWm 1A - EP JSWm 10H - EP JSWm 12H - EP JSWm 15H - EP JSWm 10M - EP JSWm 12M - EP JSWm 15M - EP JSWm 3CH - EP JSWm 3CM - EP JSWm 3CL - EP PLURIJETm 3/80 - EP PLURIJETm 4/80 - EP PLURIJETm 3/100 - EP PLURIJETm 4/100 - EP
kW
165
Single-phase
168 G1”
convertible electropumps
Convertibleelectropumpsforconnectiontoanautoclavefor automaticoperation.
PERFORMANCE TYPE
Single-phase PKm 60 - PR PKm 65 - PR PKm 70 - PR PKm 80 - PR PKSm 60 - PR PKSm 65 - PR PKSm 70 - PR PKSm 80 - PR CPm 158 - PR 2CPm 25/130N - PR 2CPm 25/140H - PR 2CPm 25/140M - PR 2CPm 80E - PR 3CPm 80E - PR 4CPm 80E - PR 3CPm 100E - PR 4CPm 100E - PR JSWm 1C - PR JSWm 1B - PR JSWm 1A - PR JSWm 10H - PR JSWm 12H - PR JSWm 15H - PR JSWm 10M - PR JSWm 12M - PR JSWm 15M - PR JSWm 3CH - PR JSWm 3CM - PR JSWm 3CL - PR JCRm 1C - PR JCRm 1B - PR JCRm 1A - PR JCRm 10H - PR JCRm 12H - PR JCRm 15H - PR JCRm 10M - PR JCRm 12M - PR JCRm 15M - PR
FLOW RATE (1)
POWER
INLETS
COMPONENTS PR
suc.
deliv.
kW
HP
Q l/min
1” 1” 1” 1” 1” 1” 1” 1” 1” 11/4" 11/4" 11/2" 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 11/4" 11/4" 11/4" 1” 1” 1” 11/4" 11/4" 11/4" 11/4" 11/4" 11/4"
1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1” 1”
0.37 0.50 0.60 0.75 0.37 0.50 0.60 0.75 0.75 0.75 1.1 1.1 0.37 0.45 0.60 0.60 0.75 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1 1.1 1.1 1.1 0.37 0.50 0.60 0.75 0.90 1.1 0.75 0.90 1.1
0.50 0.70 0.85 1 0.50 0.70 0.85 1 1 1 1.5 1.5 0.50 0.60 0.85 0.85 1 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5 1.5 1.5 1.5 0.50 0.70 0.85 1 1.25 1.5 1 1.25 1.5
32 40 50 50 32 40 50 50 90 100 100 140 50 60 60 100 100 45 50 50 50 50 50 80 80 80 70 120 160 50 50 50 50 50 50 80 80 80
(1) Maximum flow rate for the minimum recommended pressure of the pressure switch (2) Pressure switch setting (recommended)
SETTING (2) bar 1.4 1.5 1.8 2.2 1.4 1.5 1.8 2.2 1.8 1.4 2.2 2.2 1.0 1.4 2.2 1.4 2.0 1.2 1.4 1.8 2.0 2.5 3.0 1.4 2.0 2.5 3.0 2.0 1.4 1.2 1.4 1.8 2.0 2.4 3.0 1.4 2.0 2.5
÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷ ÷
2.8 3.0 3.2 3.6 2.8 3.0 3.2 3.6 3.2 2.8 3.6 3.6 2.2 2.8 3.6 2.8 3.5 2.6 2.8 3.2 3.4 4.0 4.5 2.8 3.5 4.0 4.5 3.5 2.8 2.6 2.8 3.2 3.4 3.8 4.0 2.8 3.5 4.0
- Single-phase electropump 230V - 50Hz - Pressure switch - Pressure gauge - 3 or 5-way brass fitting - 1.5 metre cable with Schuko plug
DIMENSIONS OF THE CABLES FOR SUBMERGED MOTORS SINGLE-PHASE 230 V - 50 Hz MOTOR
cable section in mm2
POWER kW
HP
0,25 0,37 0,55 0,75 1,1 1,5 2,2
0,33 0,50 0,75 1 1,5 2 3
4x1
4 x 1.5
4 x 2.5
70 60 45 35 25
105 90 70 50 35 30
170 140 110 85 60 45 30
4x4
4x6
4 x 10
4 x 16
210 145 115 75
240 190 125
305 200
cable length in metres
180 140 95 75 50
THREE-PHASE 230 V - 50 Hz MOTOR
cable section in mm2
POWER kW
HP
0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 9,2 11 13 15 18,5 22 30
0,50 0,75 1 1,5 2 3 4 5,5 7,5 10 12,5 15 17,5 20 25 30 40
4x1
4 x 1.5
4 x 2.5
100 83 65 48
152 126 99 72 53
255 210 165 120 88 60 47
4x4
4x6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
385 275 220 190 164 144 114 95 70
395 315 270 236 205 162 137 102
378 330 287 225 190 142
4 x 25
4 x 35
4 x 50
4 x 70
585 470 405 350 305 245 205 152
490 430 340 285 210
485 410 305
570 425
cable length in metres 338 265 192 142 97 73 55
405 292 215 147 110 83 60 45
485 360 245 183 138 100 73 64 54
392 295 220 160 114 100 87 75 65
510 380 275 195 157 135 117 102 82 69
THREE-PHASE 400 V - 50 Hz MOTOR
cable section in mm2
POWER
4x1
kW
HP
0,37 0,55 0,75 1,1 1,5 2,2 3 4 5,5 7,5 9,2 11 13 15 18,5 22 30
0,50 0,75 1 1,5 2 3 4 5,5 7,5 10 12,5 15 17,5 20 25 30 40
4 x 1.5
4 x 2.5
4x4
4x6
4 x 10
4 x 16
cable length in metres 300 250 195 145 105 70 55 40
380 295 215 160 110 85 60 45 35
360 265 180 140 105 75 55 47 40
425 290 220 165 120 95 75 65 60 50
Voltage drop 3% - Maximum environment temperature + 30 째C
440 330 250 180 135 115 95 85 75 58 49 36
415 300 220 190 160 140 125 100 85 63
480 340 300 260 225 195 155 130 96
DIAGRAM OF LOAD LOSSES for straight pipes 15-250 mm internal diameter and flow rate from 8 to 8330 l/min.
ter in spee m/ s d
100
Wa
50
30 20
Losses in metres for each 100 metres of pipe
10
4.6
5
3 2
1
0.5
0.3 0.2
0.1
0.05
0.03 0.02
0.01 8
16
30
50
83
160
330
500
830
1660
3330 5000
8330 Q l/min
0.5
1
2
3
5
10
20
30
50
100
200
500
300
Q m3/h
Flow rate Q
The data in the table refer to cold water and to liquids with the same kinematic viscosity, for new pipes straight from the factory, made of cast iron. The load losses hv resulting from the tables must be multiplied by: 0.8 for steel pipes, new laminates. 1.25 for old, slightly rusty, iron pipes. 1.7 for old pipes for which it is necessary to consider the reduced section due to the effect of encrustation. EXAMPLE: Flow rate data Q = 500 l/min, new steel pipe Ă˜ 80 mm, pipe length 50 m. Find the flow rate on the horizontal axis and continue vertically until you meet the line DN 80 mm. The load losses can then be read on the vertical axis. hv = 4.6 m every 100 m of pipe. hv1 = 4.6 x 0.8 = 3.68 m/100 (steel pipe). To consider the real length of the pipe: hv2 = 3.68 x 50:100 = 1.84 m (for 50 m of pipe). The speed of flow is determined considering the point of intersection which is between the oblique lines with value 1.5-2 m/sec. So in the case considered that gives: C = 1.7 metres/sec.
CONVERSION OF UNITS OF MEASUREMENT
LENGTH millimetre
centimetre
metre
inch
foot
yard
mm
cm
m
in
ft
yd
0.001 0.01 1 0.0254 0.3048 0.9144
0.0394 0.3937 39.3701 1 12 36
0.0033 0.0328 3.2808 0.0833 1 3
0.0011 0.0109 1.0936 0.0278 0.3333 1
1 10 1000 25.4 304.8 914.4
0.1 1 100 2.54 30.48 91.44
1 kilometre = 1000 metres = 0.62137 miles - 1 mile = 1609.34 metres = 1.60934 kilometres
VOLUME cubic metre
litre
millilitre
imperial gallon
US gallon
cubic foot
m3
l
ml
Imp. gal
US gal
ft3
264.2 0.2642 2.642 x 10-4 1.201 1 7.4805
35.3147 0.0353 3.53 x 10-5 0.1605 0.1337 1
long ton
short ton
1 0.001 1 x 10-6 0.00455 0.00378 0.0283
1000 1 0.001 4.546 3.785 28.317
1 x 10 1000 1 4546 3785 28.317
6
220 0.22 2.2 x 10-4 1 0.8327 6.2288
WEIGHT kilogram
pound
kg
lb
cwt
2.205 1 112 2204.6 2240 2000
0.0197 0.0089 1 19.684 20 17.857
1 0.454 50.802 1000 1016 907.2
hundredweight
ton t 0.001 4.54 x 10-4 0.0508 1 1.0161 0.9072
tn
sh. tn
9.84 x 10-4 4.46 x 10-4 0.05 0.9842 1 0.8929
0.0011 5.0 x 10-4 0.056 1.1023 1.102 1
VOLUMETRIC FLOW RATE litres
litres
cubic metres
cubic feet
cubic feet
Imp. gal.
US gal.
US barrel
second
minute
hour
hour
minute
minute
minute
day
l/s
l/min
m3/h
ft3/h
ft3/min
Imp. gal/min
US gal/min
US barrel/g
60 1 16.667 0.472 28.317 4.546 3.785 0.110
3.6 0.06 1 0.0283 1.6990 0.2728 0.2271 0.0066
127.133 2.1189 35.3147 1 60 9.6326 8.0209 0.2339
2.1189 0.0353 0.5886 0.0167 1 0.1605 0.1337 0.0039
(oil) 1 0.017 0.278 0.008 0.472 0.076 0.063 0.002
13.2 0.22 3.666 0.104 6.229 1 0.833 0.024
15.85 0.264 4.403 0.125 7.480 1.201 1 0.029
543.439 9.057 150.955 4.275 256.475 41.175 34.286 1
PRESSURE AND HEAD Newton square metre N/m 2
kiloPascal
bar
(Pa)
kPa
bar
1 1000 100000 98067 6895 2984 9789 133.3 3386
0.001 1 100 98.07 6.895 2.984 9.789 0.133 3.386
kilogram force square centimetre 5
1 x 10 0.01 1 0.981 0.069 0.03 0.098 0.0013 0.0338
pound force square inch
foot of water
metre of water
millimetre mercury
inch mercury
kgf/cm2
psi
ft H20
m H20
mm Hg
In Hg
1.02 x 105 1.02 x 105 1.02 1 0.0703 0.0305 0.1 0.0014 0.0345
1.45 x 10-4 0.145 14.5 14.22 1 0.433 1.42 0.019 0.491
3.35 x 10-4 0.335 33.52 32.81 2.31 1 3.28 0.045 1.133
1.02 x 10-4 0.102 10.2 10 0.703 0.305 1 0.014 0.345
0.0075 7.5 750.1 735.6 51.72 22.42 73.42 1 25.4
2.95 x 10-4 0.295 29.53 28.96 2.036 0.882 2.891 0.039 1
NOTES