Brandgennemføringer

Page 1

Innovations 2010.

Sound insulation

Energy efficiency

Fire protection


Innovations 2010.

Fire protection: • Portal with all applications • Action Centre to explain the new products for expert guidance and training


Innovations 2010.

Fire protection


Basic principles of building supervision.

General clause in its currently valid form: „Buildings must be constructed in such a way that fires and smoke are prevented from starting and spreading. In the event of a fire the construction of the building must also enable effective fire-fighting and fire-extinguishing prcedures and enable humans and animals to be rescued.“


Basic principles of building supervision.

• Model building regulation (MBO) • State building regulations (LBO) • • • •

Technical building regulations and norms: DIN EN 1363, DIN EN 1364, DIN 4102 MLAR, LAR, RbALei Supplementary regulations (z. B. KhBauVO, MVStättV, MvkVO, MschulbauR, MidBauRL)


Basic principles of building supervision. WE = Wohneinheit OKF = Oberkante Fußboden

Building Class 1 • free-standing building.. • bis zu 7 m Höup to 7 m high • Maximum of 1 housing unit (max. 400 m2). and • free-standing building used for agricultural forestry purposes

Building Class 2 • up to 7 m high. • maximum of two hosing unites (total of max. 400 m2).

Building Class 3 • other buildings. • up to 7 m high. • minimum of three housing units.

Building Class 4 • up to 13 m high

Building Class 5 • other buildings including unterground buildings.


Basic principles. Fire resistance class.

• Minimum preriod in minutes in which a component exposed to fire must not exceed a mean temperature rise of 140 K (max. 180 K in places) on the side not exposed to the fire. • Classes: 30 / 60 / 90 / 120 / 180 mins.


Basic principles. Fire resistance period.

Temperature increase of 140 K Ambient temperature before the fire: 22 °C < 162 °C

• Minimum period in minutes in which a component exposed to fire must not exceed a mean temperature rise of 140K (max. 180 K in places) on the side not exposed to the fire. • Classes: 30 / 60 / 90 / 120 / 180 mins.


Basic principles. Building materials. A1 non-flammable building materials

No organic components

A2 non-flammable building materials

With organic components

B1 flammable buildingmaterials

B2 flammable building materials

Hardly inflammable

Normal flammable

Example of definitions: (walls, ceilings, pillars) F30-A fire-retardant/non-flammable building materials F30-B fire-retardant / flammable building materials F90-A fireproof / non-flammable building materials F30-AB fire-retardant / non-flammable and flammable building materials


Basic principles. Fire resistance class.

Fire resistance classes acc. to DIN 4102 are designated with abbreviations depending on the component: Examples of fire resistance classes: Walls, ceilings, supports F 30 / 60 / ... Fire walls F 90 / 120 / .. FS separations (doors, etc.) T 30 / 60 / .. Cable sealings S 30 / 60 / 90 / ... Installation ducts I 30 / 60 / 90 / ... Conduit entries R 30 / 60 / 90 / ...


Fire protection according to the criminal code.

• Inadequate fire protection is not covered under VOB or BGB, but is regarded as a deliberately concealed defect. • 30-year liability for concealed defects. • In the event of harm to persons (death) the laws of the StGB § 319 (violation of building regulations endangering public safety) and § 323a (full intoxication) apply in full.


Fire protection according to the criminal code.

§ 319 Violation of building regulations (1) Any person who, during the planning, management or execution of the construction of a building … violates the generally accepted rules of technology and in so doing endangers the body or life of another person shall be punished by being sentenced to a term of imprisonment of up to five years or by a fine. (2) Equally, any person shall be punished who, in the execution of his profession or trade, violates the generally accepted rules of technology during the planning, management or execution of a plan to install technical equipment in a building, or to change installed equipment of this kind, and as a result endangers the body or life of another person. (3) Any person who causes the danger by negligence shall be punished by being sentenced to a term of imprisonment of up to three years or by a fine. (4) Any person who, in the cases as per paras. 1 and 2, acts negligently and causes the danger by reason of his negligence, shall be punished by being sentenced to a term of imprisonment of up to two years or by a fine.

• Inadequate fire protection is not covered under VOB or BGB, but is regarded as a deliberately concealed defect. • 30-year liability for concealed defects. • In the event of harm to persons (death) the laws of the StGB § 319 (violation of building regulations endangering public safety) and § 323a (full intoxication) apply in full.


AFS technology.


AFS technology.


AFS technology.


KAISER completes the range of fire protection products.


Applications.

Fire-protection FlamoX H housing For the installation of luminaires and loudspeakers in fire-protection ceilings. .


Applications.

Fire-protection FlamoX H housing For the installation of luminaires and loudspeakers in fire-protection ceilings. .


Applications.

Fire protection one-gang boxes HWD 90 For the installation of switches, sockets in fire-protection walls.


Applications.

Fire-protection one-gang boxes HWD 30 For attached luminaires, motion and fire detectors in fire-protection ceilings


Applications.

Fire-protection one-gang box HWD 90 with screw-on cover For installation as a junction box in fire protection walls.


Applications.

Box sealing system DS 90 For the wall entry and feed-through (EI 90) of cable bundles or individual electrical installation conduits.


Applications.

Cable sealing system LS 90 For the wall entry and feed-through (EI 90) of 5-15 mm electrical installation cables.


Applications.

Conduit sealing system RS 90 For the wall entry and feed-through (EI 90) of M16/20/M25 electrical installation conduits.


Examples of necessary sealings.


Sealing in accordance with MLAR. Lightweight partition wall

1. Seal e.g. mineral fibre, Melting point >1000°C, Room weight >=90 kg/m³, max. annular gap width 50 mm (e.g. exact-fitting insulating shells)

2. Seal with building materials (component thickness) which intumesce if a fire breaks out, max, annular gap width 15 mm 3. Sealing with wall manufacturer’s gypsum mortar in boarding thickness


Sealings in accordance with MLAR. Solid partition wall

1. Seal e.g. mineral fibre, Melting point >1000°C, Room weight >=90 kg/m³, max. annular gap width 50 mm (e.g. exact-fitting insulating shells) 2. Seal with building materials (component thickness) which intumesce if a fire breaks out, max, annular gap width 15 mm 3. Seal with mortar in thickness of min 40 mm)


Training courses and processing regulations for sealings.

• •

Processing regulations for craftsmen carrying out the work (a lot of training is needed) On-site stirring and processing of auxiliary materials


Disadvantages of today’s sealings. • insufficient filling depths • create a bulge • takes a long time • unclear processing • reworking in some cases • faulty processing • large number of different components • a lot of training needed • retrofitting is difficult


Goals for KAISER sealings. • guarenteed sealing

• insufficient filling depth

• without bulging

• creates a bulge

• fast and easy

• takes a long time

• clean processing

• unclean processing

• no reworking

• reworking in some cases

• fault-free

• faulty processing

• only one article

• large number of different components

• no training needed

• a lot of training needed

• easy retrofitting

• retrofitting is difficult


Sealings of feed-throughs with more than one cable. • For wall entries and feed-throughs (EI 90) • Cable bundles up to 6 cables or for individual installation conduits up to M40 • Up to 3-way group arrangement


Installation.

Hole Insert ØFX4 seal 74 mm. screw. cylinder. Multi 4000.

Bayonet fitting.


Retrofitting.

Through the wall.

Easy retrofitting. Into the wall.


Cable and Conduit arrangement .

• Group arrangement (spacing 91) up to 3 box seals • Also as reserve seal • Up to 6 NYM cables 5x1.5² • Up to 6 NYM cables 5x2.5² • Up to 3 coaxial cables • Up to 3 EDP/network cables • Up to 3 IY(ST)Y 20x2x0.6² • Individual installation conduits up to M40


Product characteristics of sealing cylinder. 2-part: • Processing around existing cables or conduits • Easy and fast installation


Product characteristics of sealing cylinder.

FX4 screw: • well-known, tried and tested fitting method • fast, safe installation


Product characteristics of sealing cylinder.

Radii in rear area:: • no sharp edges • no damage to cables with wall entries


Produkteigenschaften Dichtelement.

Hingend device: • processing around existing cables or conduits • easy, non-destructive retrofitting is possible at any time


Product characteristics of sealing element.

Bayonet fitting: • secure mechanical fitting • easy installation and removal


Product characteristics of sealing element.

Sealing element: • smoke-proof room separation (including against cold smoke) • no closing of the gusset required


Product characteristics of box sealing system DS 90.

Opposing installation: • for wall feed-throughs and entries • no filling with insulating material necessary


Product characteristics of box sealing system DS 90.

Material forms insulation layer: • intumesces if a fire breaks out • closes wall feed-throughs and entries automatically and safely


Test passed, approval applied for.

EOTA approval (European Organisation for Technical Approvals): • fire-proof

and smoke-proof room separation for at least 90 minutes (EI 90)

• visible, certified protection without on-site processing of auxiliary materials • maximum security and safety in fire protection


Additional advantages.

Installation without fire protection foam, fire protection putty or fire protection mortar: • • • • • • •

avoids insufficient filling depths no opened, encrusted cartridges no limit on service life of opened cartridges no need to use special tools no bulge or additonal planking necessary no need for training faster, safer sealing (EI 90)


Sealing of a cable.


Verarbeitung.

Through the wall.

Into the wall.


Sealing of a conduit.


Sealing of a conduit.

Cut hole Ø 35 mm. MULTI 4000.


Installation in masonry or concrete construction.

Installation Make 20 mm drill hole and insert cable Fit seal around the cable Press seal on both sides into the opening Apply the identification tag


Installation in masonry or concrete construction.

Installation Make 32 mm drill hole and insert the cable Remove the pull-off lug Fit the seal around the cable Press the seal on both sides into the opening Apply the identification tag


Product characteristics of conduit sealing system RS 90.

Opens up: • processing around existing conduits • easy, fast installation


Product characteristics of conduit sealing system RS 90. Flexible material: • permits the introduction of different conduit sizes • use of conduit sizes M20 or M25

M16,


Product characteristics of conduit sealing RS 90. Material forms an insulating layer: • intumesces if a fire starts • closes wall feed-throughs and entries automatically and safely


Product characteristics of conduit sealing RS 90. Pull-off lug: • use in solid walls • easy, toolless adaptation to Ø 32 mm drill holes


More advantages.

Installation without fire-protection foam, putty or mortar: • avoids insufficient filling depths • no opened, encrusted cartridges • no limit on service life of opened cartridges • no need to use special tools • keine Ausleibung oder Aufdoppelung notwendig • no need for training • faster and safer sealing (EI 90)


Product characteristics of cable sealing system LS 90.

Opens up: • processing around existing cables • easy, fast installation


Product characteristics of cable sealing system LS 90.

Flexible material: • permits the use of different cables • use of cable diameters from 5 to 15 mm


Product characteristics of cable sealing system LS 90. Material forms an insulating layer: • intumesces if a fire starts • closes wall feed-throughs and entries automatically and safely


Test passed, approval applied for.

EOTA approval (European Organisation for Technical Approvals): • fire-proof and smoke-proof room separation (EI 90) for at least 90 minutes • visible, certified protection without on-site processing of auxiliary materials • maximum safety in fire protection


More advantages.

Installation without fire protection foam, fire protection putty or fire protection mortar: • • • • • • •

avoids insufficient filling depths no opened, encrusted cartridges no limit on service life of opened cartridges no need to use special tools no bulge or additonal planking necessary no need for training faster, safer sealing (EI 90)


Identification of the sealings.

Proof • •

All sealings must be identified Identification tag in 4 languages - D/GB, F, I - D/GB, NL, F


Technical data.

Identification tag •

for all KAISER sealings

made of plastic

with two 4.5 mm drill holes


Box sealing system DS 90.

• • • • • •

Safe, visible, certified fire sealings For wall feed-throughs and entries No filling or smearing Automatic sealing of the joints and gusset Non-destructive retrofitting of cables For cable bundles or individual installation conduits


Cable sealing system LS 90.

• • • • • •

Safe, visible, certified fire sealings For wall feed-throughs and entries No filling or smearing Also for use as wall entry Automatic sealing of the joints For cables of Ø 5-15 mm


Conduit sealing system RS 90.

• • • • •

Safe, visible, certified fire sealings No filling or smearing Also for use as wall entry Automatic sealing of the joints For M16-M25 conduits


The product range FlamoX-E Art. No. 9435-01

FlamoX-E Art. No. 9435-02

FlamoX-H Art. No. 9430-01 Fire protection putty Art. No. 9400-05


The product range One-gang box HWD 90 Art. No. 9463-01

One-gang junction box HWD 90 Art. No. 9464-01


The product range Ceiling box HWD 30 Art. No. 9463-50

Ceiling junction box HWD 30 Art. No. 9464-50

Fire-protection cover HWD 30 - 90 Art. No. 1184-94


The product range Box sealing system DS 90 Art. No. 9459-03

Cable sealing system LS 90 Art. No. 9459-01

Identification tag

Conduit sealing system RS 90

Art. No. 9473-91, -92

Art. No. 9459-02


The product range Box sealing system DS 90 Art. No. 9459-03

Cable sealing system LS 90 Art. No. 9459-01

Identification tag Art. No. 9473-91, -92

Conduit sealing system RS 90 Art. No. 9459-02


The product range One-gang box HWD B15 Art. No. 9463-15

One-gang box HWD B15 One-gang junction box HWD B15

- for thin boarding Art. No. 9463-14

Art. No. 9464-15 One-gang box HWD B15 Art. No. 9461-15 One-gang junction box HWD B15 - for thin boarding

One-gang box HWD B15

Art. No. 9464-15

- for thin boarding Art. No. 9461-14


Light & Building 2010.

2010 Thank you.