Fibrain FOC 2016

Page 1


fiber optic cables fibrain Information

Application FOC Parameters Low Loss Fibers SM/MM Bendsafe Fibers Fiber and Cables Information Fiber Identification

Page 5

Page 5 Page 6 Page 7 Page 8 Page 9 Page 10

DATACOM

Page 16

FTTH

Page 34

Furcation tube FSMX Buffer BFR Simplex SMX Duplex ZIP LDC LBR DC-PRIM DC-DRIM EXO-CU EXO-C0 EXO-CI EXO-GU EXO-G0 EXO-GI BDC-MSA

VC-D20 VC-D30 VC-D40 VC-DCY Resibend® Cables VC-D30 Resibend® VC-D30 Resibend Plus® Easy Section Module Cables VC-D30 Easy Section Module VC-D40 Easy Section Module DC-PRIM EAC-RAs EAC-RAm DAC-BURRY VC-T60 Aero-DF03

Page 17 Page 18 Page 19 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32

Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50

content

5

16

34


fiber optic cables fibrain MICRODUCT

Page 51

Telecom Duct

Page 63

Telecom Aerial

Page 71

Special Cable Designs

Page 83

MK-AX2 MK-DX2/25/3 MK-LX4 MK-LXS6/7/8 MK-LXS9/10 MK-LX6 MK-LX7 MK-LX8 MK-LX9 MK-LX11

BDC-MSA BDC-MIB BDC-C0 BDC-CI BDC-CK DDC-SI DDC-CI

Aero-DF03 Aero-AS02 2.0 mm Aero-AS03 2.0 mm Aero-AS03 2.5 mm Aero-AS04 2.0 mm Aero-AS04 2.5 mm Aero-AS06 2.0 mm Aero-AS06 2.5 mm Aero-AS09 2.5 mm Aero-AS12 2.5 mm Aero-AS14 2.5 mm

FTTA-DAC BDC-CIP 1.5 mm2 BDC-CIP 0.5 mm2 H05V-U BDC-CIP 0.75 mm2 H05V-U BDC-CIP 1.00 mm2 H05V-U BDC-DIP 1.50 mm2 H07V-U BDC-DIP 2.50 mm2 H05V-U BDC-DID 0.80 mm

Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62

Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70

Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82

Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91

content

51

63

71

83


Information


Mechanical features

symbols Basic Rodent Protection

High Rodent Protection

Rodent Protection Extreme

Flexible

Last mile connection outdoor

Aerial

Hi-crush

Direct buried

Duct

Microduct Generation 1

ETR

Industrial

Mining

Military

Oil resistance

Ship and oshore

Robotic

Windfarms

Datacenter

Datacom

Telecom

FTTH

FTTA

Semi-tight

Easy-strip

LSOH

Compact design

Flexible

MultiďŹ ber connectors termination

Easy to terminate

Last mile connection indoor

Bendsafe

Low Friction

Blowing installation

Design features

Branch of business

Optimal Diameter

Hybrid FO + Power

symbols | 5


FOC

FOC Parameters

parameters single-mode fiber types

Fiber types and applications

Maximum attenuation for uncabled fibers IL [dB/km]

Fiber type ITU-IT

Possibility to remove the 900 μm coat at the distance of 3-5 cm

1383 nm

1410 nm

1450 nm

1490 nm

≤0.34

≤0.31

-

-

≤0.24

≤0.20

≤0.23

Premium single mode fiber low loss G.652D LL with zero water-peak and lower attenuation in whole bandwidth

≤0.32

≤0.31

-

-

≤0.21

≤0.18

≤0.20

Long distance single mode fiber with non-zero dispersion shifted G.655 – (NZDSF) for CWDM and DWDM A,B,C,D system 10G and future 40G or 100G

-

≤0.40

≤0.32

≤0.26

-

≤0.19

≤0.21

Long distance single mode fiber G.656 – with non-zero dispersion shifted A,B,C,D (NZDSF) for CWDM and DWDM system 10G and future 40G or 100G

-

≤0.40

≤0.32

≤0.26

-

≤0.19

≤0.21

Available bend radius

Bend insensitive fiber fully G.657A1 compatible with G.652D standard, bend radius 10-15 mm

≤0.35

≤0.35

-

-

≤0.24

≤0.20

≤0.23

BEND RADIUS

Bend insensitive fiber fully G.657A2 compatible with G.652D standard, bend radius 7.5 mm

≤0.35

≤0.35

-

-

≤0.24

≤0.20

≤0.23

Bend insensitive fiber fully G.657B3 (A3) compatible with G.652D standard, bend radius 5 mm

≤0.35

≤0.35

-

-

≤0.24

≤0.20

≤0.23

Bend insensitive fiber, non-compatible with G.652D standard, for G.657B3 Plus connectorization application, bend radius 2.5 mm

≤0.35

Standard single mode telecommuG.652D nication fiber with zero water-peak attenuation

-

≤0.35

-

1550 nm 1625 nm

Tight 900 μm fiber

1310 nm

≤0.24

≤0.21

≤0.23

Semi-tight 900 μm fiber

Possibility to remove the 900 μm coat at the distance of 10-20 cm

Easy strip 900 μm fiber

Possibility to remove the 900 μm coat at the distance of 100-150 cm

7.5

BEND RADIUS

10

mm

mm

BEND RADIUS

BEND RADIUS

15

mm

30

mm

multimode fiber types BEND RADIUS

Overfilled modal bandwidth [MHz/km]

Fiber type ITU-T

Fiber Capacity [m]

Attenuation [dB/km]

Bending loss 2 turns [dB]

Bending loss 10 turns [dB]

Radius = 7.5 mm Radius = 15 mm

Radius = 30 mm

850 nm

40GBASE1300 SR4/ 1GBase-SR 10GBase-SR nm 100GBASESR10

850 nm

1300 nm

62.5/125 OM1

≥ 160

≥ 500

275

-

-

2.6

0.5

50/125 OM2 Bend Insensitive

≥ 500

≥ 500

600

83

-

2.3

0.5

≥ 0.2

≥ 0.5

≥ 0.1

≥ 0.3

-

50/125 OM3 Bend Insensitive

≥ 1500

≥ 500

1000

300

140*

2.4

0.5

≥ 0.2

≥ 0.5

≥ 0.1

≥ 0.3

-

50/125 OM4 Bend Insensitive

≥ 3500

≥ 500

1100

550

170*

2.4

0.6

≥ 0.2

≥ 0.5

≥ 0.1

≥ 0.3

-

850 nm

1300 nm

850 nm

1300 nm

-

850 nm 1300 nm ≥ 0.5

* Maximum cabled fiber attenuation 3.0 dB/km at 850 nm, maximum total connector loss of 1.0 dB and VCSELs maximum RMS spectral width of 0.29 nm (according to IEEE 10GbE model: http://grouper.ieee.org/groups/802/3/ae/public/adhoc/serial_pmd/documents/10GEPBud3_1_16a.xls).

Bending loss G.652D

Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.03 dB

Mandrel R=25 mm 1310/1550 nm 100 turns 0.03 dB

Mandrel R=15 mm 10 turn 1550 nm ≤0.25 dB 1625 nm ≤1.0 dB

G.652D LL

Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.03 dB

Mandrel R=25 mm 1310/1550 nm 100 turns 0.03 dB

Mandrel R=15 mm 10 turn 1550 ≤0.25 dB 1625 nm≤1.0 dB

G.655 – A.B.C.D

Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.05dB

Mandrel R=15 mm 1550/1625 nm 1 turn ≤0.5 dB

G.656 – A.B.C.D

Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.05 dB

Mandrel R=15 mm 1550/1625 nm 1 turn ≤0.5 dB

G.657A1

Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn 1550 nm 1550nm≥0.20 dB. 1625 nm ≤0.50 dB ≥0.50 dB. 1625 nm ≤1.50 dB

G.657A2

Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn 1550 nm≥0.03 dB. 1625nm ≤0.10 dB 1550 nm≥0.10 dB. 1625 nm ≤0.2dB;

Mandrel R=7.5 mm 1 turn 1550 nm ≥0.50 dB. 1625 nm ≤1.0 dB

G.657B3 (A3)

Mandrel R=10 mm 1 turn Mandrel R=7.5 mm 1 turn 1550 nm 1550 nm≥0.03 dB. 1625 nm ≤0.10 dB ≥0.05 dB. 1625 nm ≤0.15 dB

Mandrel R=5 mm 1 turn 1550 nm≥0.10 dB. 1625 nm ≤0.30 dB

G.657B3 Plus

Mandrel R=5 mm 1 turn Mandrel R=2.5 mm 1 turn 1550 nm 1550 nm≥0.10 dB. 1625nm ≤0.20 dB ≥0.20 dB. 1625 nm ≤0.30dB

40

mm

BEND RADIUS

60

mm


low loss

Low Loss Fibers

fibers

At present, low loss and pure quartz optic fibers with max. 0.17 dB/km attenuation at 1550 nm wavelength and max. 0.31 dB/km at 1310 nm wavelength are ready for use. Low loss and pure quartz optic fibers have at least 0.02 dB/km lower spectral attenuation in comparison to the standard ones G.652D. In such fibers, the retention of flat spectral characteristics within the transmission windows provide the possibility of achieving substantially smaller deviations of attenuation: ÆÆ 1310 nm (+ 20 nm / -35 nm) wavelength – max. deviation is 0.03 dB/km ÆÆ 1550 nm ( + 25 nm / -25 nm) wavelength – max. deviation is 0.02 dB/km with the retention of 1625 nm attenuation 0.20 dB/km.

The chromatic dispersion complies with ITU-T G.652 and the polarizing at the level of ≤ 0.04 ps/√km of these fibers provides the possibility of using such fibers in high- speed systems e.g. transmission of 10 GBit/s or even higher. Low loss fibers which are obtained in the pure quartz technology can work properly in telecommunication networks at the distance of even thousand kilometers far, which significantly limits the number of necessary amplifiers and repeaters in a fiber optic connection.

0.40 0.30

G.657.A1

G.652.D LL

G.652.D

G.657.A1

G.652.D LL

G.652.D

G.657.A1

G.652.D LL

G.652.D

G.657.A1

G.652.D LL

G.652.D

0

G.657.A1

0.10

G.652.D LL

0.20 G.652.D

Attenuation [dB/km]

Attenuation / Wavelength

25 16

50 15

90 14

83 13

10 13

Wavelength [nm]

low loss Fibers Introduction | 7


low loss

Low Loss Fibers

fibers

Performance Specifications Parameter

Value

Attenuation [dB/km] 1310 nm 1383 ± 3 nm 1490 nm 1550 nm 1625 nm

≤ 0.32 ≤ 0.32 ≤ 0.21 ≤ 0.18 ≤ 0.20

Attenuation Difference [dB/km] The attenuation from λ1 [nm] to λ2 [nm] shall not exceed the attenuation at λ3 [nm] by more than Δ

λ1 1285 1525

λ2 1330 1575

λ3 1310 1550

Δ 0.03 0.02

nm 1550 1310 1550 1625

dB ≤0.03 ≤0.03 ≤0.03 ≤0.03

Point Discontinuity [dB] 1310 nm and 1550 nm

≤ 0.05

Optical Return Loss [dB] Absolute value at all points along the fiber

Attenuation with Bending [dB]

Cable Cutoff Wavelength [nm]

≥ 60 Turns 1 100 100 100

mm 32 50 50 60 ≤ 1260

Mode Field Diameter [µm] 1310 nm

9.2±0.4

1550 nm

10.4±0.5

Dispersion [ps/(nm•km)] 1550 nm 1625 nm Zero Dispersion Wavelength - λo [nm] Zero Dispersion Slope - So [ps/(nm2•km)]

≤ 18.0 ≤ 22.0 1304 to 1324 ≤ 0.092

Polarization Mode Dispersion (ps/√km) Individual fiber

≤ 0.1

Link value

≤ 0.04

Environmental / Attenuation Effects (dB/km) Temperature Dependence (–60°C to +85°C) Temperature-Humidity Cycling (-10°C to +85°C with humidity cycling up to 98% RH)

1310 / 1550 / 1625 nm ≤ 0.05 ≤ 0.05

Dry Heat Soak (85±2°C)

≤ 0.05

Water Immersion (23±2°C)

≤ 0.05

Damp Heat Soak (85±2°C, 85% RH, 30 Days)

≤ 0.05

Fiber Curl

≤ 0.05

Deflection for 10 mm overhang (µm)

≤12.4

Corresponding radius of curvature (meters)

≥ 4.0

Minimum Strength (by Proof Test) Operating Temperature Range

8 | foc low loss fibers

0.69 GPa (100 kpsi) -60°C to +85°C


SM/MM

SM/MM Fibers

BENDSAFE FIBERS

Available bend radius BEND RADIUS

BEND RADIUS

BEND RADIUS

10

7.5

BEND RADIUS

15

BEND RADIUS

30

mm

mm

mm

mm

G.657B2,B3

G.657B3

G.652A1,A2

G.652D

BEND RADIUS

40

60

mm

mm

Bendsafe SM Fibers

10 7,5

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

0.10dB 0.03dB

G.657B3 (A3)

1.00dB 0.50dB

0.20dB 0.10dB

G.657A2 0.10dB 0.03dB

1.50dB 0.50dB

0.50dB 0.20dB

G.657A1

Max. attenuation for wavelength 1550 nm 1625 nm/both [dB]

15

0.50dB

0.05dB

0.05dB

G.656 - A.B.C.D

0.50dB

G.655 - A.B.C.D

1.00dB 0.25dB

0.03dB

0.03dB

30

0.03dB

0.03dB

Bend radius [mm]

40

G.652D LL

1.00dB 0.25dB

G.652D

60

Bendsafe MM Fibers

10

0.20dB 0.50dB

0.10dB 0.30dB

0.20dB 0.50dB

50/125 OM4 Bend Insensitive

Bending loss for wavelength 850nm 1300nm/both [dB]

15

0.10dB 0.30dB

30

0.20dB 0.50dB

Bend radius [mm]

40

50/125 OM2 50/125 OM3 Bend Insensitive Bend Insensitive

0.10dB 0.30dB

60

7,5

FOC sm/mm bendsafe fibers | 9


FOC

Post-production fiber parameters Type

Fiber and cables Information

fiber and cables information

Tight buffer vs. Loose tube Attenuation [dB/km]

1310

1550

850

1300

Low Loss (LL)

0.34

0.22

-

-

Telecom

0.35

0.25

-

-

Standard

0.40

0.30

-

-

Datacom

0.40

0.30

3.50

1.50

2-3mm 900µm

900 µm outer coating

Tube

Gel

Core

125 µm coating

Stripping Tight buffer Tight 900 μm fiber

Semi-tight Semi-tight 900 μm fiber

Easy strip Easy strip 900 μm fiber

Possibility to remove the 900 μm coat at the distance of 3-5 cm

Possibility to remove the 900 μm coat at the distance of 10-20 cm

Possibility to remove the 900 μm coat at the distance of 100-150 cm.

10 | foc fiber and cables information

Loose tube

Tight buffer

250 µm coating


FOC

telecom

fiber identification

Fiber color codes in Loose tube cable design Other colors available on demand T-Telecom (according to IEC 60304) 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Code

12

1

2 3

11

Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

10

4 9

Color

5 8

Code red

green

blue

white

violet

orange

grey

yellow

brown

pink

natural

7

6

aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

T1-TELecom (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02) 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Code

12

Color

red

blue

white

green

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

2 3

10

4 9

5 8

Code Color

1

11

red

blue

white

green

violet

orange

grey

yellow

brown

pink

natural

7

6

aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

T2-TELecom (according to EIA 598A) 1-12

1

2

3

4

5

6

7

8

9

10

11

12 12

Code

2 3

11

Color

blue

orange

green

brown

grey

white

red

black

yellow

violet

pink

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

10

4 9

5 8

Code Color

1

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

7

6

aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

FOC fiber color codes | 11


FOC

telecom

fiber in Loose tube color codes

Loose tube color codes in Loose tube cable design Other colors available on demand t-telecom - Loose tube in cable (according to iec60304): Tube

1

2

3

4

5

6

7

8

9

10

11

12

12

Code Color

1

2

11

3

9

5

10

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

4

8

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

7

6

t1-telecom - Loose tube in cable (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02) Tube

1

2

3

4

5

6

7

8

9

10

11

12

12

Code Color

1

2

11

3

9

5

10

red

blue

white

green

violet

orange

grey

yellow

brown

pink

black

aqua

4

8

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

7

6

t2-telecom - Loose tube in cable (according to EIA 598A) Tube

1

2

3

4

5

6

7

8

9

10

11

12

12

Code Color

1

2

11

3

9

5

10

blue

orange

green

brown

grey

white

red

black

yellow

violet

pink

aqua

4

8

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

7

6

t3-telecom - Loose tube in cable according to IEC 60304) Tube

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Code Color

3

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

luminous red

patina green

1

2

3

4

5

6

7

8

9

10

11

12

signal blue

red

green

white

white

white

white

white

white

white

white

white

white

Code

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

12 | foc fiber color codes

1

4

12

5 6

11 10

E-telecom - Loose tube in cable (according to EIA 598A)

Color

2

13

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

Tube

1

15 14

2

9

8

7


FOC

datacom

fiber color codes

Fiber, buffer and tubes color codes for Datacom cables range Other colors available on demand D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) Fiber in buffer 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark green

orange

pink

5

6

7

8

9

10

11

12

Fiber Buffer 250/900/600 µm

Fiber Buffer 250 µm

600/900 µm

*Buffer with black mark to identifiy fibers 13-24

Fibers in tubes 1-12

1

2

3

4

24

Code

13 1

23

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

yellow

white

grey

brown

violet

aqua

dark green

orange

15

22

16

21

17 20

Code Color

14 2

19

18

pink

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Loose tubes in cables Tube

1

2

3

4

5

6

7

8

9

10

11

12

12

Code Color

1

2 3

11

red

green

blue

white

violet

orange

grey

yellow

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

brown

pink

black

aqua

10

4 9

5 8

7

6

FOC fiber color codes | 13


FOC

datacom

fiber color codes

Fiber and buffer color codes for datacom cables range Other colors available on demand D1-DATACOM (according to IEC 60304 ; TIA/EIA 598-A ; TIA/EIA 598-C /Data Center cables) Fiber in buffer 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Color

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

Color*

blue

orange

green

brown

grey

white

red

dark green

yellow

violet

pink

aqua

5

6

7

8

9

10

11

12

Fiber Buffer 250/900/600 µm

Fiber Code 250 µm

600/900 µm

*Buffer with black mark to identifiy fibers 13-24

Fibers in tubes 1-12

1

2

3

4

24

Code

13 1

23

Color

blue

orange

green

brown

grey

white

red

yellow

yellow

violet

pink

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

blue

orange

green

brown

grey

white

red

natural

yellow

violet

pink

aqua

14 2

15

22

16

21

17 20

19

18

Code Color

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Loose tubes in cables Tube

1

2

3

4

5

6

7

8

9

10

11

12 12

Code Color

1

2 3

11

red

green

blue

white

violet

orange

grey

yellow

**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers

14 | foc fiber color codes

brown

pink

black

aqua

10

4 9

5 8

7

6


FOC

ftth

fiber color codes

Fiber and buffer color codes for FTTH cables range Other colors available on demand F-FTTH (according to DIN VDE 0888 & IEC 60304) 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

Color*

red

blue

green

yellow

violet

white

orange

grey

brown

dark green

aqua

pink

Fiber Buffer 250 µm

600/900 µm

Fiber Code 250 µm

600/900 µm

*Buffer with black mark to identifiy fibers 13-24

FOC fiber color codes | 15


FIBRAIN COATINGS

Industrial

Oil resistance

Mining

Ship and oshore

Military

Windfarms

Robotic

Datacenter

Telecom

Physical properties of coatings PE polyethylene

LSOH

PVC polyvinyl chloride

PUR polyurethane

PA polyamide

NBR nitrile rubber

Mechanical resistance

Mechanical resistance

Mechanical resistance

Mechanical resistance

Mechanical resistance

Mechanical resistance

Temperature resistance

Temperature resistance

Temperature resistance

Temperature resistance

Temperature resistance

Temperature resistance

Chemical resistance

Chemical resistance

Chemical resistance

Chemical resistance

Chemical resistance

Chemical resistance


datacom

Furcation tube FSMX 1.6 - 2.8 mm

furcation tube fsmx Cable structure

1

1. LSOH outer jacket 2. Aramid yarns 3. Central Tube 900 μm

2 3

TRUE COLORS

Flexible

Easy to terminate

Bendsafe

Configuration

FSMX Ø nominal ± 5% [mm]

Version

Nominal weight ± 5% [kg/km]

Max. installation tension (ε=0.5 %) [N]

Crush [N/10 cm]

FSMX 1.8

1.8/0.9/0.5

4

100

200

FSMX 2.8

2.8/0.9/0.5

8

350

300

Applications ÆÆ

Distribution systems cable

ÆÆ

For patchcords and pigtails

ÆÆ

Terminals connection

Jacket colors

Standard

Features

Yellow RAL 1021 White RAL 9010

Blue RAL 5015

Orange RAL 2003

Aqua RAL 6027

Violet RAL 4003

ÆÆ

LSOH with low coefficient of friction

ÆÆ

Aramid yarns

ÆÆ

Central tube 900 µm

Low-radius bending resistance SM

Color codes 30 mm

4

5

6

7

8

9

10

11

12

Fiber Buffer Color 900 µm

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

15 mm

G.657A1

7.5 mm

G.657A2

pink

Operating temperature +100 +70°C +55°C

-5°C -10°C

TRANSPORT

3

OPERATION

2

G.652D

INSTALLATION

1

temperature [°C]

1-12

bend radius [mm]

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers

-40°C

-100

datacom furcation tube fsmx | 17


datacom

Buffer BFR 0.6 - 0.9 mm

Buffer bFR Cable structure

1

1. Outer Tight Buffer Tube 600/900 µm (LSOH) 2. Colored coating on fiber 250 µm 3. Optical Fiber with cladding 125 µm

3

2

TRUE COLORS

Flexible

Easy to terminate

Semi-tight

Easy-strip

Bendsafe

Configuration

BFR Version

Fiber qty

Ø nominal ± 5% [mm]

Max. installation tension ± 5% [N]

1F

1

0.6

4

1F

1

0.9

5

Applications

Crush [N/10cm] 200

ÆÆ

Distribution systems cable

ÆÆ

For patchcords and pigtails

ÆÆ

Terminals connections

Available outer jacket colors

SM G.652D Yellow RAL 1021

Features

SM G.657 MM 62.5/125 OM1 A1 / A2 / A3 Blue RAL 5015 White RAL 9010

MM 50/125 OM2 Orange RAL 2003

MM 50/125 OM3 Aqua RAL 6027

MM 50/125 OM4 Violet RAL 4003

Stripping

250 µm fiber

ÆÆ

Variants with different stripability

1

TB00 / TB05 / TB10

+100 +70°C +55°C

3-5 / 10-20 / 100-150

Color codes D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers 1

2

3

4

5

6

7

8

9

10

11

-5°C -10°C

12 -40°C

Fiber

-100

Buffer red

green

blue

yellow

white

18 | datacom buffer bfr cables

grey

brown

violet

aqua

black

orange

pink

TRANSPORT

1F

Stripping - length in one piece [cm]

OPERATION

1

Stripping

INSTALLATION

1F

Color

ÆÆ

temperature [°C]

Fiber qty

250/600/900 µm

Buffer made of LSOH with low coefficient of friction

Operating temperature

Version

1-12

ÆÆ


datacom

Simplex SMX 1.2 - 2.8 mm

simplex smx cable Cable structure

1

1. LSOH outer jacket 2. Aramid yarns 3. Central tight buffer Tube 600/900 μm

2 3

TRUE COLORS

Flexible

Easy to terminate

Semi-tight

Easy-strip

Bendsafe

Configuration

smx Version

Ø nominal ± 5% [mm]

Fiber qty

Max. installation tension (ε=0.5 %) [N]

Crush [N/10 cm]

1F

1

1.2

50

200

1F

1

1.6

100

300

1F

1

1.8

150

400

1F

1

2.0

200

500

1F

1

2.8

300

800

Applications ÆÆ

Distribution systems cable

ÆÆ

For patchcords and pigtails

ÆÆ

Terminals connection

Features

Jacket colors

Standard

ÆÆ

LSOH with low coefficient of friction

ÆÆ

Aramid yarns

ÆÆ

Central tight buffer tube 600/900 µm

ÆÆ

250 µm colored fiber

Low-radius bending resistance SM Blue RAL 5015

Orange RAL 2003

Aqua RAL 6027

Violet RAL 4003

Color codes D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers 1-12

1

2

3

4

5

6

7

8

9

30 mm bend radius [mm]

Yellow RAL 1021 White RAL 9010

10

11

G.652D

15 mm

G.657A1

7.5 mm

G.657A2

12

Fiber

Operating temperature blue

yellow

white

grey

brown

violet

aqua

black

orange

+100

pink

+70°C +55°C

-5°C -10°C

TRANSPORT

green

OPERATION

red

temperature [°C]

Color

250/600/900 µm

INSTALLATION

Buffer

-40°C

-100

datacom simplex smx cables | 19


DATACOM CABLES

TRUE COLORS

Selection of tubes and cables colors Other colors available on demand

orange

green

grey

red

violet

yellow

black

brown

pink

aqua


datacom

Duplex Zip Cables 1.6 - 2.8 mm

duplex zip cables

1

Cable structure 1. LSOH outer jacket 2. Aramid yarns 3. Central tight buffer Tube 600/900 µm with colored fibers 250 µm

2

3

TRUE COLORS

LSOH

Bendsafe

Easy to terminate

Easy-strip

Semi-tight

Configuration

ZIP Fiber qty

Dimensions nominal ± 5% [mm]

Max. installation tension (ε=0.5 %) [N]

Crush [N/10 cm]

2F

2

1.6 x 3.3

200

500

2F

2

1.8 x 3.7

300

500

2F

2

2.0 x 4.1

400

500

2F

2

2.8 x 5.7

600

1000

Applications ÆÆ

Distribution systems cable

ÆÆ

Patchcords and pigtails

ÆÆ

Terminals connection

Structure and composition

Jacket colors

Standard

MM 50/125 OM2 Orange RAL 2003

250 µm colored fibers

SM low-radius bending resistance 30 mm

15 mm

G.657A1

7.5 mm

G.657A2

Operating temperature +100 +70°C +55°C

-5°C -10°C

TRANSPORT

MM 50/125 OM4 Violet RAL 4003

G.652D

OPERATION

MM 50/125 OM3 Aqua RAL 6027

MM 62,5/125 OM1 Blue RAL 5015

Aramid yarns

ÆÆ

bend radius [mm]

SM G.657 A1 / A2 / A3 White RAL 9010

LSOH with low coefficient of friction

ÆÆ

temperature [°C]

SM G.652D Yellow RAL 1021

ÆÆ

INSTALLATION

Version

-40°C

-100

datacom DUPLEX ZIP CABLES | 21


datacom

LDC

LDC Cable structure

1

3

2

1. Outer jacket LSOH UV Stabilized 2. Tight Tubes 900 µm (LSOH) with colored fibers 250 µm 3. Aramid yarns

TRUE COLORS

LSOH

Bendsafe

Easy to terminate

Semi-tight

Easy-strip

Datacenter

Configuration

LDC Version

Tight buffers [pcs]

Ø ± 5% [mm]

Nominal weight LSOH ± 5% [kg/km]

2F

2

4.5

21

4F

4

5.0

26

6F

6

5.5

30

8F

8

5.5

35

10F

10

6.5

40

12F

12

6.5

45

16F

16

7.0

50

24F

24

8.0

65

Max. tensile load [N] installation

operation

500

Crush [N/10 cm]

125 500

700

175

1000

250

Applications ÆÆ

Indoor/outdoor installations

ÆÆ

Distribution networks in multifamily buildings

ÆÆ

FTTD Connections

ÆÆ

Distribution systems

ÆÆ

Fully dielectric

ÆÆ

LAN and FTTX network

ÆÆ

ODF connection

ÆÆ

Datacenter distribution

Features Jacket colors

ÆÆ

Compact design

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers

ÆÆ

Lightweight

ÆÆ

Flexible

ÆÆ

Easy to strip

ÆÆ

Fully dielectric

ÆÆ

Reduced diameter

ÆÆ

Direct connectorization

1-12

1

2

3

4

5

6

7

8

9

10

11

12

Fiber Buffer Color

250/600/900 µm

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Operating temperature +100

Fiber

+70°C

Code yellow

white

grey

brown

violet

aqua

natural orange

pink

Color*

red

green

blue

yellow

white

grey

brown

violet

brown

dark green

pink

600/900 µm

*Buffer with black mark to identifiy fibers 13-24

orange

-5°C -10°C

-40°C

-100

22 | datacom LDC

TRANSPORT

blue

OPERATION

green

INSTALLATION

red

250 µm

temperature [°C]

+55°C

Color


datacom

LBR

LBR Cable structure 1. Outer jacket LSOH UV Stabilized 2. Subcables 1.8 mm with tight tubes 900 µm (LSOH) with 250 µm colored fibers

1 2

3

3. Aramid yarns 4. Central FRP strength member 5. Ripcord

1 2

3

4

TRUE COLORS

LSOH

Bendsafe

Easy to terminate

Semi-tight

Easy-strip

5

Datacenter

Configuration

LBR Version

Fiber qty

Ø ± 5% [mm]

Nominal weight LSOH ± 5% [kg/km]

installation

operation

4F

4

6.5

48

750

250

6F

6

7.5

63

1200

400

8F

8

8.7

85

1500

12F

12

10.9

131

Max. tensile load [N]

1500

Crush [N/10 cm]

Applications ÆÆ

Indoor/outdoor installations

ÆÆ

Distribution networks in multifamily buildings

ÆÆ

FTTD Connections

ÆÆ

Distribution systems

500

ÆÆ

Fully dielectric

500

ÆÆ

LAN and FTTX network

ÆÆ

ODF connection

ÆÆ

Datacenter distribution

16F

16

11.3

119

1700

550

18F

18

11.3

131

1700

550

24F

24

13.0

179

2000

660

2000

Features

Standard jacket colors:

PE Black RAL9005

LSOH Grey RAL7022

ÆÆ

Simplex sub cable up to 24 fibers

ÆÆ

Fully dielectric cable

ÆÆ

Aramid yarns as tensile elements

ÆÆ

UV Resistant and LSOH flame retardant outer jacket

LSOH Light Grey RAL7037

Operating temperature +100

Outer jacket color options:

+70°C

SM G.652D RAL 1021

SM G657A1, A2, A3 RAL 9010

MM 50/125 OM2 RAL 2003

MM 50/125 OM3 RAL6027

MM 50/125 OM4 RAL4003

TRANSPORT

OPERATION

-5°C

INSTALLATION

temperature [°C]

+55°C

-20°C -40°C

-100

datacom LBR | 23


datacom

DC-PRIM

DC-PRIM Cable structure

1

1. LSOH outer jacket 2. Aramid yarns 3. 250 µm optical fibers

2 3

TRUE COLORS

LSOH

Bendsafe

Easy to terminate

Datacenter

Configuration

DC-PRIM No. of fibers

12

24

Outer diameter [mm] (±5%)

3.0

3.5

Max tensile load (ε=0.5%) [N]

350

350

8

9

Weight [kg/km] (±10%) Crush [N/10 cm]

Applications

350

Min. bend radius [mm]

45 (depends on fiber type)

60 (depends on fiber type)

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

Customer connection, fully dielectric cable

ÆÆ

MTP/MPO termination cable

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

Inside house OLT connection

ÆÆ

Data Center connections cable

Outer jacket color options:

Features Ivory RAL 1015

Yellow RAL 1021

White RAL 9010

Blue RAL 5015

Orange RAL 2003

Green RAL 6018

Aqua RAL 6027

Violet RAL 4003

ÆÆ

Aramid strength element

ÆÆ

250 µm optical fibers (12-24)

ÆÆ

LSOH outer jacket

Available colors Operating temperature

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1

2

3

4

5

6

7

8

9

10

11

+100

12

+70°C

Fiber blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fiber Code Color*

red

green

blue

*Fiber with black mark to identify fibers 13-24

24 | datacom DC-PRIM

yellow

white

grey

brown

violet

brown

dark green

orange

pink

-5°C -10°C

-40°C

-100

TRANSPORT

green

OPERATION

red

temperature [°C]

+55°C

Color

INSTALLATION

1-12


datacom

DC-DRIM

DC-DRIM

1

1

Cable structure

2

2

1. LSOH outer jacket 2. Aramid yarns 3. LSOH inner jacket 4. Aramid yarns 5. 250 µm optical fibers

3

3 5

4

TRUE COLORS

LSOH

Bendsafe

Easy to terminate

Datacenter

Configuration

DC-DRIM No. of fibers

12

24

Outer diameter [mm] (±5%)

4.5

5.0

Max tensile load (ε=0.5%) [N]

600

600

8

9

Weight [kg/km] (±10%) Crush [N/10cm]

Applications

300

Min. bend radius [mm]

65 (depends on fiber type)

75 (depends on fiber type)

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

Customer connection, fully dielectric cable

ÆÆ

MTP/MPO termination cable

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

Inside house OLT connection

ÆÆ

Data Center connections cable

Outer jacket color options:

Features Ivory RAL 1015

Yellow RAL 1021

White RAL 9010

Blue RAL 5015

Orange RAL 2003

Green RAL 6018

Aqua RAL 6027

Violet RAL 4003

ÆÆ

Aramid strength element in two layers

ÆÆ

250 µm optical fibers (12-24)

ÆÆ

LSOH double jacket

Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1

2

3

4

5

6

7

Operating temperature 8

9

10

11

12

+100 +70°C

Fiber blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Fiber Code Color*

red

green

blue

*Fiber with black mark to identify fibers 13-24

yellow

white

grey

brown

violet

brown

dark green

orange

+55°C

-5°C -10°C

TRANSPORT

green

OPERATION

red

temperature [°C]

Color

INSTALLATION

1-12

pink -40°C

-100

datacom DC-DRIM | 25


datacom

EXO-CU Cables Loose tube

exo-cU cables

1

Cable structure

Datacom

ETR

Compact design

1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord

Basic Rodent Protection

LSOH

LSOH Jacket

Exo-CU Version

Fiber qty

Ø ± 5% [mm]

Max. tensile load [N] installation

1T x 2F

2

6.4

47

1T x 4F

4

6.8

48

1T x 6F

6

6.8

51

(ε=0,33%)

1T x 8F

8

6.8

51

1600

1T x 12F

12

6.8

52

1T x 24F

24

7.1

62

4

5

Configuration Nominal weight LSOH ± 5% [kg/km]

3

2

Crush [N/10 cm]

operation

1100

300

700

Applications ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

(ε=0,5%)

Features

Available colors

ÆÆ

Fiberglass strength element

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound

ÆÆ

Loose tube (PBT)

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

LSOH outer jacket

1

2

3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

aqua

dark green

Code green

blue

yellow

white

grey

brown

violet

orange

pink

+100 +70°C

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Fiber identification

Jacket colors

Standard 24

13 1

23

14 2

16

21

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3 RAL 9010

MM 50/1025 OM2 RAL 2003

26 | datacom exo-CU cables

MM 50/1025 OM3 RAL6027

MM 50/1025 OM4 RAL4003

-40°C

17 20

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

-5°C -10°C

15

22

PE Black RAL 9005

temperature [°C]

+55°C

19

18

-100

TRANSPORT

red

OPERATION

Color

Operating temperature

INSTALLATION

1-12


datacom

EXO-C0 Cables Loose tube

exo-c0 cables

1

Cable structure

Datacom

ETR

Compact design

1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord

Basic Rodent Protection

LSOH

LSOH Jacket

Exo-C0 Fiber qty

1T x 2F

2

6.8

52

1T x 4F

4

7.2

53

1Tx 6F

6

7.2

57

1T x 8F

8

7.2

58

1T x 12F

12

7.2

58

1T x 16F

16

7.4

62

1T x 24F

24

7.4

62

Max. tensile load [N] installation

Crush [N/10 cm]

operation

1300

(ε=0,33%)

500

1900

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

1500

(ε=0,5%)

Features

Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1

2

3

4

5

6

7

8

9

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Code

ÆÆ

Fiberglass strength element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound

ÆÆ

Loose tube (PBT)

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

LSOH outer jacket

Operating temperature +100

Code green

blue

yellow

white

grey

brown

violet

dark green

aqua

orange

pink

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Fiber identification

Jacket colors

+55°C

-5°C -10°C

TRANSPORT

red

temperature [°C]

Color

+70°C

OPERATION

1-12

Applications

INSTALLATION

Version

Ø ± 5% [mm]

4

5

Configuration Nominal weight LSOH ± 5% [kg/km]

3

2

Standard 24

13 1

23

-40°C

14 2

15

22

16

21

17 20

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

-100

19

18

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3 RAL 9010

MM 50/1025 OM2 RAL 2003

MM 50/1025 OM3 RAL6027

MM 50/1025 OM4 RAL4003

datacom exo-c0 Cables | 27


1

Cable structure

Compact design

Basic Rodent Protection

LSOH

5

LSOH Jacket

Configuration

Exo-CI Version

Fiber qty

Nominal weight LSOH ± 5% [kg/km]

Ø ± 5% [mm]

1T x 2F

2

7.1

52

1T x 4F

4

7.4

53

1Tx 6F

6

7.4

57

1T x 8F

8

7.4

58

1T x 12F

12

7.4

58

1T x 16F

16

7.7

62

1T x 24F

24

7.7

62

Max. tensile load [N] installation

Crush [N/10 cm]

operation

1800

(ε=0,33%)

1000

2700

2

3

4

5

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

1500

Features

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1

Applications

(ε=0,5%)

Available colors 1-12

6

7

8

9

10

11

12

Code Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

aqua

dark green

ÆÆ

Fiberglass strength element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound

ÆÆ

Loose tube (PBT)

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

LSOH outer jacket

Operating temperature

Code red

green

blue

yellow

white

grey

brown

violet

+100 orange

+55°C

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Fiber identification

Jacket colors

Standard 24

13 1

23

15

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

PE Black RAL 9005

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3 RAL 9010

17 19

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

MM 50/1025 OM2 RAL 2003

28 | datacom exo-CI CABLES

MM 50/1025 OM3 RAL6027

MM 50/1025 OM4 RAL4003

-40°C 16

21

PE Black RAL 9005

-5°C -10°C

14 2

22

20

+70°C

pink temperature [°C]

Color

4

18

-100

TRANSPORT

ETR

3

2

INSTALLATION

Datacom

1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord

OPERATION

datacom

EXO-CI Cables Loose tube

exo-cI cables


datacom

EXO-GU Cables Loose tube

exo-GU cables

1

Cable structure

Datacom

ETR

Compact design

1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord

Basic Rodent Protection

LSOH

LSOH Jacket

Exo-GU Version

Fibers per tube

Fiber qty

Ø ± 5% [mm]

1T x 2F

2

2

5.8

34

1T x 4F

4

4

5.8

34

1T x 6F

6

6

5.8

35

1T x 8F

8

8

5.8

35

1T x 12F

12

12

5.8

35

1T x 16F

16

16

5.8

35

1T x 18F

18

18

5.8

36

1T x 24F

24

24

5.8

36

Max. tensile load [N] installation

4

5

Configuration Nominal weight LSOH ± 5% [kg/km]

3

2

Crush [N/10 cm]

operation

1200

(ε=0,33%)

400

1500

Applications ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

1500

(ε=0,5%)

Features

Available colors

ÆÆ

Central Loose tube (PBT) with filling compound

ÆÆ

Optical fibers

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

LSOH outer jacket

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 4

5

6

7

8

9

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

yellow

white

grey

brown

violet

aqua

dark green

orange

pink

Code

Code Color

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;

Fiber identification

Jacket colors

Standard 24 23

+55°C

-5°C -20°C

15

16

21

17 20

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

+70°C

14 2

22

PE Black RAL 9005

+100

-100

13 1

Operating temperature

TRANSPORT

3

OPERATION

2

INSTALLATION

1

temperature [°C]

1-12

19

18

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3 RAL 9010

MM 50/1025 OM2 RAL 2003

MM 50/1025 OM3 RAL 6027

MM 50/1025 OM4 RAL 4003

datacom exo-GU Cables | 29


datacom

EXO-G0 Cables Loose tube

exo-G0 cables

1

Cable structure

Datacom

ETR

Compact design

1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord

Basic Rodent Protection

LSOH

LSOH Jacket

Exo-G0 Version

1T x 2F

Fiber qty 2

2

Ø ± 5% [mm] 5.9

Applications

Max. tensile load [N]

Nominal weight LSOH ± 5% [kg/km]

Crush [N/10 cm]

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

37

ÆÆ

Distribution network

ÆÆ

ODF connections

1T x 4F

4

4

5.9

37

1T x 6F

6

6

5.9

37

1T x 8F

8

8

5.9

37

1T x 12F

12

12

5.9

38

1T x 16F

16

16

5.9

38

1T x 18F

18

18

5.9

38

1T x 24F

24

24

5.9

40

installation

4

5

Configuration

Fibers per tube

3

2

operation

1500

(ε=0,33%)

500

2200

1500

Features

(ε=0,5%)

Available colors

ÆÆ

Central Loose tube (PBT) with filling compound

ÆÆ

Optical fibers

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

LSOH outer jacket

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 4

5

6

7

8

9

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

yellow

white

grey

brown

violet

aqua

dark green

orange

pink

Code

Code Color

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;

Fiber identification

Jacket colors

Standard 24 23

14 2

15

22

16

21

17 20

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3 RAL 9010

MM 50/1025 OM2 RAL 2003

30 | datacom exo-g0 CABLES

MM 50/1025 OM3 RAL 6027

MM 50/1025 OM4 RAL 4003

19

+100 +70°C +55°C

-5°C -20°C

-100

13 1

Operating temperature

18

TRANSPORT

3

OPERATION

2

INSTALLATION

1

temperature [°C]

1-12


datacom

EXO-GI Cables Loose tube

exo-GI cables

1

Cable structure

Datacom

ETR

Compact design

1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord

Basic Rodent Protection

LSOH

3

2

5

LSOH Jacket

Configuration

Exo-GI Version

Fiber qty

Ø ± 5% [mm]

Fibers per tube

Applications

Max. tensile load [N]

Nominal weight LSOH ± 5% [kg/km]

installation

4

Crush [N/10 cm]

operation

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

1T x 2F

2

2

6.1

38

1T x 4F

4

4

6.1

38

1T x 6F

6

6

6.1

39

1T x 8F

8

8

6.1

40

1T x 12F

12

12

6.1

40

1T x 16F

16

16

6.1

41

1T x 18F

18

18

6.1

42

ÆÆ

Central Loose tube (PBT) with filling compound

42

ÆÆ

Optical fibers

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

LSOH outer jacket

1T x 24F

24

24

6.1

1800

(ε=0,33%)

600

2700

1500

(ε=0,5%)

Features

Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 4

5

6

7

8

9

10

11

12

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

yellow

white

grey

brown

violet

aqua

dark green

orange

pink

Code

Code Color

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;

Fiber identification

Jacket colors

Standard 24 23

+70°C +55°C

-5°C -20°C

14 2

15

22

16

21

17 20

PE Black RAL 9005

+100

-100

13 1

Operating temperature

TRANSPORT

3

OPERATION

2

INSTALLATION

1

temperature [°C]

1-12

19

18

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

Optional

SM G.652D RAL 1021

SM G657 A1, A2, A3 RAL 9010

MM 50/1025 OM2 RAL 2003

MM 50/1025 OM3 RAL 6027

MM 50/1025 OM4 RAL 4003

datacom exo-GI Cables | 31


datacom

DATACOM BDC-MSA

bdc-MSA

1

Cable structure 6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord

1. LSOH outer jacket 2. Water-blocking fiberglass yarns 3. Water blocking yarns 4. PET tape 5. Central strength member (FRP)

Datacom

ETR

Compact design

2 4

5

3 6

7 8

Basic Rodent Protection Datacenter

LSOH

Configuration

BDC-msa Fibers per tube

Total elements

Ø ± 5% [mm]

Active tubes

installation

Crush

[N/10 cm]

operation

1T x 12F

12

12

6

1

8.2

50

65

1500

550

2T x 6F

12

6

6

2

8.2

50

65

1550

780

2T x 12F

24

12

6

2

8.2

51

65

1500

550

4T x 6F

24

6

6

4

8.2

51

66

1550

780

3T x 12F

36

12

6

3

8.2

52

67

1500

550

6T x 6F

36

6

6

6

8.2

53

68

1550

780

4T x 12F

48

12

6

4

8.2

53

68

1500

550

5T x 12F

60

12

6

5

8.2

54

69

1500

550

6T x 12F

72

12

6

6

8.2

54

69

1500

550

8T x 12F

96

12

8

8

9.3

71

86

1620

750

12T x 12F

144

12

12

12

11.5

104

126

1620

850

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

Features 1500

ÆÆ

FRP strength and anti-buckling element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 1.8 mm)

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass as water absorbent and strain relief element

ÆÆ

UV stabilized LSOH jacket

Operating temperature

Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 2

3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Tubes Tube

1

2

3

4

5

6

7

8

9

10

11

12

Code Color

+70°C +55°C

-5°C -20°C -40°C

red

green

blue

yellow

white

*In case of lower fiber count some tubes can be replaced by fillers.

32 | datacom bdc-MSA cables

grey

brown

violet

aqua

black

orange

pink

-100

TRANSPORT

1

temperature [°C]

1-12

+100

OPERATION

Fibers

INSTALLATION

Version

Applications

Max. tensile load [N]

Nominal weight LSOH ±5% [kg/km]

Nominal weight PE ±5% [kg/km]


FTTH Cables


VC-D20/VC-D30 VC-D40/VC-DCY SOLID CONNECTION TO YOUR PROVIDER

BEND

RESISTANCE

EASY TO

TERMINATE

LSOH

SAFE COVER

SMALL DIMENSIONS

SAFE

DAILY USE


ftth

FTTH VC-D20

VC-d20

1

Cable structure

2 3

1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber

Last mile connection outdoor

LSOH

Flexible

Easy to terminate

Bendsafe

FTTH

Configuration

VC-d20 No. of fibers

Applications

1F 900 µm ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

Customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

10-60 mm*

ÆÆ

LAN and FTTX networks

300

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

Outer diam [mm]

2.0

Tensile load perm/inst. [N]

75/200

Weight [kg/km]

7

Min. bend radius [mm] Crush [N/10 cm] *Depends on fiber type

Bend radius/maximum attenuation Features ÆÆ

Aramid strength element

ÆÆ

Optical 900 µm semi tight tube

ÆÆ

LSOH outer jacket

Operating temperature +100 +70°C

-5°C

TRANSPORT

+55°C OPERATION

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.657B3 (A3) 0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

1.50dB 0.50dB

0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

0.03dB

G.657A2

INSTALLATION

7,5

G.657A1

temperature [°C]

10

G.652D LL

Max. attenuation for wavelength 1550 nm 1625nm/both [dB]

15

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

-20°C -40°C

-100

ftth VC-D20 cables

| 35


ftth

FTTH VC-D30

VC-d30

1

2 3

Cable structure 1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber

Last mile connection outdoor

LSOH

Flexible

Easy to terminate

Bendsafe

FTTH

Configuration

VC-d30 No. of fibers

Applications

1F 900 µm

Outer diam [mm]

3.0

Tensile load perm/inst. [N]

60/170

Weight [kg/km]

8

Min. bend radius [mm]

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

Customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

10-60 mm*

ÆÆ

LAN and FTTX networks

500

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

Crush [N/10 cm] *Depends on fiber type

Bend radius/maximum attenuation

10 7,5

Features

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.657B3 (A3) 0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

1.50dB 0.50dB

G.657A2

Max. attenuation for wavelength 1550 nm 1625nm/both [dB]

15

G.657A1 0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

G.652D LL

0.03dB

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

ÆÆ

Aramid strength element

ÆÆ

Optical 900 µm semi tight tube

ÆÆ

LSOH outer jacket

Operating temperature +100

-20°C -40°C

-100

36 | ftth VC-D30 cables

TRANSPORT

-5°C

OPERATION

+55°C INSTALLATION

temperature [°C]

+70°C


ftth

FTTH VC-D40

VC-d40

1

Cable structure 1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber

Last mile connection outdoor

LSOH

Flexible

Easy to terminate

2

3

Bendsafe

FTTH

Configuration

VC-d40 No. of fibers

Applications

1-2F 900 µm ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

Customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

10-60 mm*

ÆÆ

LAN and FTTX networks

1000

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

Outer diam [mm]

4.0

Tensile load perm/inst. [N]

150/400

Weight [kg/km]

15

Min. bend radius [mm] Crush [N/10 cm] *Depends on fiber type

Bend radius/maximum attenuation Features ÆÆ

Aramid strength element

ÆÆ

Optical 900 µm semi tight tube

ÆÆ

LSOH outer jacket

Operating temperature +100 +70°C

-5°C

TRANSPORT

+55°C OPERATION

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.657B3 (A3) 0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

1.50dB 0.50dB

0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

0.03dB

G.657A2

INSTALLATION

7,5

G.657A1

temperature [°C]

10

G.652D LL

Max. attenuation for wavelength 1550 nm 1625nm/both [dB]

15

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

-20°C -40°C

-100

ftth VC-D40 cables

| 37


ftth

FTTH VC-DCY

VC-dcy

3

2

Cable structure 1. LSOH outer jacket (white/ivory/black) 2. FRP rod 3. 250 µm optical fibers

Last mile connection outdoor

LSOH

Flexible

Easy to terminate

Bendsafe

FTTH

Hi-crush

Configuration

VC-dCY No. of fibers

Applications

1-4F 900 µm

Outer diam [mm]

ÆÆ

FTTH drop cable reinforced with FRP rods

ÆÆ

Customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

15-40 mm*

ÆÆ

LAN and FTTX networks

1000

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

2.0x3.1 ±0.1

Tensile load perm/inst. [N]

50/100

Weight [kg/km]

8.3

Min. bend radius [mm] Crush [N/10 cm] *Depends on fiber type

Bend radius/maximum attenuation

10 7,5

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.657B3 (A3) 0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

0.10dB 0.03dB

1.50dB 0.50dB

G.657A2

Max. attenuation for wavelength 1550 nm 1625nm/both [dB]

15

G.657A1 0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

G.652D LL

0.03dB

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

Features ÆÆ

FRP rods

ÆÆ

250 µm optical fibers

ÆÆ

LSOH outer jacket

Operating temperature +100

-30°C

-100

38 | ftth VC-Dcy cables

TRANSPORT

OPERATION

INSTALLATION

temperature [°C]

+70°C +55°C

1



ftth

FTTH VC-D30 RESIBEND®

VC-d30 resibend®

1 3

Cable structure

2

1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber

Resibend®

Last mile connection outdoor

LSOH

Flexible

Easy to terminate

FTTH

Bendsafe

Configuration

VC-d30 resibend® No. of fibers

Applications

1F 900 µm

Outer diam [mm]

3.0

Tensile load perm/inst. [N]

60/170

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

For customer connection

ÆÆ

Fully dielectric cable

Weight [kg/km]

8

Min. bend radius [mm]

ÆÆ

Last mile connection

10

ÆÆ

LAN and FTTX networks

Crush [N/10 cm]

500

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

Bend radius/maximum attenuation

G.657B3 (A3) Fiber bending radius [mm] 5

Max. change in attenuation [dB]

Features

1550 nm

1625 nm

0.10

0.25

ÆÆ

Aramid yarns as strain relief

ÆÆ

Optical fiber in 900 µm semi tight buffer

ÆÆ

LSOH outer jacket (various colors available)

ÆÆ

G.657B3 A3 optical fibers

7.5

0.05

0.15

10

0.03

0.10

Operating temperature +100

-20°C -40°C

-100

40 | ftth VC-D30 resibend® cables

TRANSPORT

-5°C

OPERATION

+55°C INSTALLATION

temperature [°C]

+70°C


ftth

FTTH VC-D30 RESIBEND PLUS®

VC-d30 resibend plus®

1 3

Cable structure

2

1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber

Resibend Plus®

Last mile connection outdoor

LSOH

Flexible

Easy to terminate

FTTH

Bendsafe

Configuration

VC-d30 resibend plus® No. of fibers

Applications

1F 900 µm

Outer diam [mm]

3.0

Tensile load perm/inst. [N]

60/170

Weight [kg/km]

8

Min. bend radius [mm]

7.5

Crush [N/10 cm]

500

Bend radius/maximum attenuation

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

For customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

G.657B3 Plus Fiber bending radius [mm]

Max. change in attenuation [dB]

Features

1550 nm

1625 nm

2.5

0.20

0.30

ÆÆ

Aramid yarns as strain relief

5

0.10

0.20

ÆÆ

Optical fiber in 900 µm semi tight buffer

ÆÆ

LSOH outer jacket (various colors available)

ÆÆ

G.657B3 optical fibers

Operating temperature +100

TRANSPORT

-5°C

OPERATION

+55°C INSTALLATION

temperature [°C]

+70°C

-20°C -40°C

-100

ftth VC-D30 resibend plus® cables

| 41



ftth

FTTH VC-D30 Easy Section Module

VC-d30 Easy Section Module

1 3

Cable structure

2

1. LSOH outer jacket 2. Aramid yarns 3. Optical fibers (250 µm) in Easy Section Module

Last mile connection outdoor Last mile connection outdoor

Easy Section Module

Bendsafe LSOH

Easy to terminate

Flexible

Bendsafe

FTTH

Configuration

VC-D30 Easy Section Module Active modules

2F

2

2

1

1

3.1

9

4F

4

4

1

1

3.1

9

allowed

170

static

60

Applications Crush [N/10 cm]

1000

Bend radius/maximum attenuation

7,5

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

G.657B3 (A3) 0.10dB 0.03dB

1.00dB 0.50dB

0.20dB 0.10dB

G.657A2 0.10dB 0.03dB

1.50dB 0.50dB

0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

0.03dB

G.657A1

Optical cable with aramid yarns reinforcement

ÆÆ

For customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

Features ÆÆ

Aramid strength element

ÆÆ

Optical fibers (up to 4 pcs) inside 900µm FlexModule

ÆÆ

LSOH outer jacket

Operating temperature +100 +70°C temperature [°C]

10

G.652D LL

Max. attenuation for wavelength 1550 nm 1625nm/both [dB]

15

0.03dB

30

0.03dB

Bend radius [mm]

40

1.00dB 0.25dB

G.652D

60

ÆÆ

+55°C

-5°C

TRANSPORT

Total elements

Max. tension [N]

OPERATION

Fibers

Nominal weight ±5% [kg/km]

Ø ± 5% [mm]

INSTALLATION

Version

Fibers per module

-20°C -40°C

-100

ftth Vc-d30 Easy Section Module

| 43


ftth

FTTH VC-D40 Easy Section Module

VC-d40 Easy Section Module

1 3

Cable structure

2

1. LSOH outer jacket 2. Aramid yarns 3. Optical fibers (250 µm) in Easy Section Module

Easy Section Module

Last mile connection outdoor

LSOH

Easy to terminate

Flexible

Bendsafe

FTTH

Configuration

VC-D40 Easy Section Module Version

Fibers

Fibers per module

Total elements

Active modules

Nominal weight ±5% [kg/km]

Ø ± 5% [mm]

2F

2

2

1

1

4.1

15

4F

4

4

1

1

4.1

15

Max. tension [N] allowed

420

static

150

Applications Crush [N/10 cm]

1000

Bend radius/maximum attenuation

10 7,5

0.30dB 0.20dB

G.657B3 Plus 0.20dB 0.10dB

0.30dB 0.10dB

0.15dB 0.05dB

0.10dB 0.03dB

1.00dB 0.50dB

G.657B3 (A3)

Max. attenuation for wavelength 1550 nm 1625nm/both [dB]

15

0.20dB 0.10dB

G.657A2 0.10dB 0.03dB

1.50dB 0.50dB

G.657A1 0.50dB 0.20dB

1.00dB 0.25dB

0.03dB

G.652D LL

0.03dB

30

0.03dB

Bend radius [mm]

40

0.03dB

60

1.00dB 0.25dB

G.652D

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

For customer connection

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

ODF connections

ÆÆ

Inside house OLT connection

Features ÆÆ

Aramid strength element

ÆÆ

Optical fibers (up to 4 pcs) inside 900µm FlexModule

ÆÆ

LSOH outer jacket

Operating temperature +100

-20°C -40°C

-100

44 | ftth VC-D40 Easy Section Module

TRANSPORT

-5°C

OPERATION

+55°C INSTALLATION

temperature [°C]

+70°C


ftth

DC-PRIM

DC-PRIM

1

Cable structure

2

1. LSOH outer jacket 2. Aramid yarns 3. 250 µm optical fibers

3

TRUE COLORS

LSOH

Bendsafe

Datacenter

Easy to terminate

Configuration

DC-PRIM

Applications

No. of fibers

12

24

Outer diameter [mm]

3.0

3.5

350/150

350/150

8

9

45 (depends on fiber type)

50 (depends on fiber type)

Tensile load perm/inst. [N] Weight [kg/km] Min. bend radius [mm] Min. bend radius [mm]

150

ÆÆ

Optical cable with aramid yarns reinforcement

ÆÆ

Customer connection, fully dielectric cable

ÆÆ

MTP/MPO termination cable

ÆÆ

LAN and FTTX networks

ÆÆ

Distribution network

ÆÆ

Inside house OLT connection

ÆÆ

Data Center connections cable

Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Features

Fiber

ÆÆ

Aramid strength element

Color

red

green

blue

yellow

white

grey

brown

violet

aqua

black

orange

pink

ÆÆ

250 µm optical fibers (12-24)

13-24

13

14

15

16

17

18

19

20

21

22

23

24

ÆÆ

LSOH outer jacket

Fiber

Operating temperature blue

*Fiber with black mark to identify fibers 13-24

yellow

white

grey

brown

violet

brown

dark green

orange

+100

pink

+70°C +55°C

-5°C

TRANSPORT

green

OPERATION

red

temperature [°C]

Color*

INSTALLATION

Code

-20°C -40°C

-100

ftth DC-PRIM

| 45


ftth

FTTH EAC-RAs

EAC-Ras Cable structure 1. LSOH outer jacket 2. Dielectric strength members 3. 900 µm semi tight buffer (LSOH) with colored 250 µm optical fiber

1 2

3

Last mile connection outdoor

LSOH

FlexibleEasy to Easy to terminate terminate

Bendsafe

FTTH

Configuration

EAC-Ras

Version

Fibers

Nominal weight ±5% [kg/km]

Ø ± 5% [mm]

Buffers

Max. tensile load [N]

Applications Crush [N/10 cm]

installation

8F

8

8

8.7

68

400

12F

12

12

8.7

72

400

16F

16

16

12.0

98

600

24F

24

24

12.0

106

600

2

3

4

5

6

7

For laying in risers

ÆÆ

FTTH feeder

ÆÆ

Easy access and installation

Features

F-FTTH (according to DIN VDE 0888 & IEC 60304) 1

Distribution cable

ÆÆ

1000

Available colors 1-12

ÆÆ

8

9

10

11

ÆÆ

FRP strength members inside cable jacket

ÆÆ

Optical fibers in bundles

ÆÆ

2-24 elements in cable

ÆÆ

LSOH UV resistant outer jacket (ivory by default, various colors available)

12

Fiber

Operating temperature green

yellow

violet

white

orange

grey

brown

black

aqua

pink

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

600/900 µm

Fiber Code Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

Color*

red

blue

green

yellow

violet

white

orange

grey

brown

dark green

aqua

pink

250 µm

600/900 µm

*Buffer with black mark to identifiy fibers 13-24

+100 +70°C +55°C

-5°C

TRANSPORT

blue

OPERATION

red

250 µm

INSTALLATION

Color

temperature [°C]

Buffer

-20°C -40°C

-100

Fiber extraction up to 25 m

Fiber extraction

46 | ftth EAC-RAs cables


ftth

FTTH EAC-RAm

EAC-RAm Cable structure 1. LSOH outer jacket 2. Dielectric strength members 3. FlexModules with 250 µm colored fiber

1 2

3

Easy Section Module

Last mile connection outdoor

LSOH

Easy to terminate

Flexible

Bendsafe

FTTH

Configuration Last mile

connection outdoor

Version

EAC-RAm

Fibers

Ø ± 5% [mm]

FlexModules

Nominal weight ±10% [kg/km]

Max. tensile load [N] ε=0.6% Δ α≤ 0.1 dB, reversible

Crush [N/10 cm]

2F FlexModules 12-18

6-9

8,7

69

400

20-30

10-15

9,5

79

400

32-48

16-24

12,0

106

600

16-36

4-9

8,7

70

400

40-48

10-12

9,5

78

400

52-60

13-15

10,5

85

400

64-96

16-24

12,0

110

600

500

Applications ÆÆ

Distribution cable

ÆÆ

For laying in risers

ÆÆ

FTTH feeder

ÆÆ

Easy access and installation

4F FlexModules

Features

500

6F FlexModules 70

400

30-72

5-12

78-96

13-16

10,5

90

400

12,0

112

600

102-144

17-24

13,0

130

600

16-32

2-4

8,7

67

400

40-96

5-12

10,5

89

400

24-48

2-4

8,7

70

400

60-120

5-8

10,5

90

400

48

9-12

12,0

115

600

2-24 elements in cable

ÆÆ

LSOH UV resistant outer jacket (ivory by default, various color available)

500

Operating temperature +100

8F FlexModules

+70°C

temperature [°C]

500

12F FlexModules 500

+55°C

-5°C

TRANSPORT

8,7

Optical fibers in bundles

ÆÆ

OPERATION

2-4

FRP strength members inside cable jacket

ÆÆ

INSTALLATION

12-24

ÆÆ

-20°C -40°C

F-FTTH (according to DIN VDE 0888 & IEC 60304) 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color 250 µm

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color

red

blue

green

yellow

violet

white

orange

grey

brown

black

aqua

pink

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

blue

green

yellow

violet

white

orange

grey

brown

dark green

aqua

pink

-100

Fiber

Fiber extraction up to 25 m

Module Fiber extraction

Module Color*

*Black mark to identify FlexModules 13-24

ftth EAC

| 47


ftth

FTTH DAC-BURRY

DAC-Burry

1

Cable structure

2

1. PP/HDPE outer jacket 2. Aramid yarns 3. Central Loose tube (PBT) with 250 µm colored fibers in filling gel 4. Dielectric strength members in the jacket

Direct buried

Last mile connection outdoor

FTTH

Hi-crush

4

3

Compact design

Configuration

DAC-BURRY Version

Fibers

Fibers per tube

Ø ± 5% [mm]

Nominal weight PE ± 5% [kg/km]

1T x 2F

2

2

6.2

32

1T x 4F

4

4

6.2

32

1Tx 6F

6

6

6.2

32

1T x 8F

8

8

6.2

32

1T x 12F

12

12

6.2

32

Max. tensile load [N] installation

operation

650

Applications Crush [N/10 cm]

250

3500

ÆÆ

Optical access cable with aramid yarns reinforcement

ÆÆ

Direct buried design

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

ÆÆ

High crush resistance (3,5kN)

ÆÆ

Installation into existing ducts or direct buried

Features

Available colors T-Telecom (according to IEC 60304) - Fibers in tube 1-12

1

2

3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

ÆÆ

Central Loose tube (PBT) with filling compound

ÆÆ

Up to 12 optical fibers (250 µm)

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

Embedded FRP strength members

ÆÆ

Highly resistant outer jacket made of hard polyolefin material, UV resistant

Operating temperature +100

-40°C

-100

48 | ftth DAC-BURRY cables

TRANSPORT

OPERATION

-15°C

INSTALLATION

temperature [°C]

+70°C +55°C


ftth

VC-T60

vc-t60 Cable structure 1. HDPE UV resistant outer jacket 2. Aramid yarns 3. Inner LSOH jacket 4. FRP rods 5. Module with optical fibers

1

3

2

5 4

TRUE COLORS

LSOH

Bendsafe

Easy-strip

Easy to terminate

Semi-tight

Datacenter

Configuration

VC-t60

1-4

allowed

static

1

5.6

30

1200

400

Applications Crush [N/10 cm] 2000

ÆÆ

Drop cable for FTTH networks

ÆÆ

Optical access cable with aramid yarns reinforcement

ÆÆ

Direct buried construction

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

Features ÆÆ

Aramid yarns as strength and water absorbent elements

ÆÆ

Easy strip buffer or modules with optical fibers

ÆÆ

Embedded strength members (FRP)

ÆÆ

Highly resistant outer jacket made of HDPE material

ÆÆ

UV stabilized

Operating temperature +100 +70°C span: 100 m

sag: 2.2 m

+55°C

-5°C

TRANSPORT

NESC Light

OPERATION

1-4

Total elements

Nominal weight ±5% [kg/km]

INSTALLATION

1-4F

Fibers

Max. tensile load [N]

Ø ± 5% [mm]

temperature [°C]

Version

Fibers per module

-20°C -40°C

NSC Medium span: 55 m

-100 sag: 1.1 m

NESC Heavy span: 30 m

sag: 0.6 m

ftth VC-t60

| 49


ftth

FTTH aero-df03

aero-df03 Cable structure 4. Central Loose tube (PBT) with 250 µm colored fibers in filling gel 5. FRP strength member

1. PE jacket 2. Ripcord 3. Water blocking yarns

Last mile connection outdoor

Aerial

4

3

5

Telecom

Hi-crush

FTTH

1 2

Cable variants Version

AERO-DF03

AERO-DF03

Fiber count

1-12

16-24

Cable dimensions [mm]

8.3 x 4.6 (±3%)

8.7 x 5.0 (-3%)

Cable weight [kg/km]

37

38

Max. installation tension[N]

1300

1300

Applications

Mechanical and enviromental characteristics

ÆÆ

Installation on poles or walls

ÆÆ

Can be installed in pipelines

ÆÆ

Fully dielectric cable

Parameter Crush performance

5000 N

Bending performance

10 cycles [20 x D]

Water Penetration

3 m sample, 1 m head, 24 h

Features ÆÆ

Loose tube with filling compound (PBT)

ÆÆ

Up to 24 fibers in a cable

Available colors

ÆÆ

Two FRP strength elements

T-Telecom (according to IEC 60304) - Fibers in tube

ÆÆ

Dry yarns to prevent moisture into cable

ÆÆ

Ripcord yarns For easy jacket removal

ÆÆ

PE UV resistant Jacket

1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Code

Operating temperature +100

Code white

violet

orange

grey

yellow

brown

pink

natural

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm NESC Light

aqua

-15°C

span: 120 m

-40°C

sag: 2.4 m

NSC Medium span: 70 m

sag: 1.4 m

NESC Heavy span: 40 m

sag: 0.8 m

50 | ftth AERO-DF03

-100

TRANSPORT

blue

OPERATION

green

INSTALLATION

red

temperature [°C]

Color

+70°C +55°C


Microduct


TRENCH

MICROCABLES

OPTIMAL DIAMETER HIGH BLOWING RANGE HIGH FIBERS DENSITY

LOW FRICTION COEFFICIENT

UNIT DESIGN


microduct

MICRODUCT MK-AX2

MK-AX2

1

Cable structure 1. Polymeric jacket with low coefficient of friction 2. 250 µm colored fibers

Microduct Generation 1

Last mile connection outdoor

FTTH

Blowing installation

Flexible

Compact design

2

Bendsafe

Configuration

MetroJET MK-AX2 Fibers

1T x 2F

2

1.1

1.2

1T x 4F

4

1.1

Max. install. tension [N]

Crush [N/10 cm]

ÆÆ

Microduct air-blowing application

ÆÆ

Metro networks

1.4

ÆÆ

Flexible network design

ÆÆ

Distribution network

1.6

1T x 8F

8

1.5

1.8

1T x 10F

10

1.6

2.0

1T x 12F

12

1.6

2.2

15

100

Features

Compatibility table

standard microduct Version

[mm]

Inner Ø [mm]

Direct burried ducts

MK-AX2 2-4F

6-12F

Outer Ø [mm]

Inner Ø [mm]

7/3.5

7

3.5

Version

2-4F

5/3.5

5

3.5

7/3.8

7

3.8

7/5.5

7

5.5

7/4

7

4

10/8

10

8

10/5.5

10

5.5

12/10

12

10

12/8

12

8

-

12

14/10

14

10

-

Fiber qty

Available colors

2-12

Fiber qty

ÆÆ

250 µm colored fibers

Operating temperature

2.1

14

Central tube without gel

6-12F

3

14/12

Polymeric jacket with low coefficient of friction

ÆÆ

MK-AX2

3/2.1

-

ÆÆ

+100 +70°C +55°C

2-12

-15°C

OPERATION

1.5

INSTALLATION

6

Outer Ø

Applications

temperature [°C]

1T x 6F

Nominal weight ±10% [kg/km]

TRANSPORT

Version

Ø ± 5% [mm]

-30°C -40°C

-100

microduct MK-Ax2 | 53


microduct

MICRODUCT MK-DX2/25

MK-DX2/25

1

Cable structure

2

1. HDPE with low coefficient of friction 2. Aramid yarns 3. Central Loose tube (PBT) with 250 µm colored fibers in filling gel

Blowing installation

Flexible

Compact design

Bendsafe

MetroJET MK-DX2/25 Nominal weight ±10% [kg/km]

Ø ± 5% [mm]

Fibers

1T x 2F

2

2.0

3,9

1T x 4F

4

2.0

3.9

1T x 6F

6

2.3

4.4

1T x 8F

8

2.3

4.5

1T x 10F

10

2.3

4.6

1T x 12F

12

2.3

4.6

Applications

Max. installation tension [N]

Crush [N/10 cm]

300

500

direct burried ducts

Inner Ø

MK-DX2

MK-DX25

3/2.1

3

2.1

-

-

5/3.5

5

3.5

-

7/5.5

7

5.5

10/8

10

8

12/10

12

10

-

14/12

14

12

[mm]

[mm]

Fiber qty

FTTH & Distribution networks

ÆÆ

Flexible network design

ÆÆ

Last mile connection

ÆÆ

Blowing & pulling installation method

Outer Ø

Inner Ø

7/3.5

7

3.5

7/3.8

7

3.8

7/4

7

4

10/5.5

10

5.5

-

12/8

12

8

-

-

14/10

14

10

2-4

4-12

Version

[mm]

[mm]

Fiber qty

MKDX2

MKDX25 -

ÆÆ

HDPE with low coefficient of friction

ÆÆ

Aramid yarns

ÆÆ

Central tube with gel

ÆÆ

250 µm colored fibers

ÆÆ

Microbending resistant fiber G657A1 as standard

Operating temperature +100 +70°C +55°C

-

-

2-4

4-12

temperature [°C]

standard microduct Outer Ø

Microduct cabling system

ÆÆ

Features

Compatibility table

Version

ÆÆ

INSTALLATION

Version

-15°C -30°C

Available colors

-40°C

T-Telecom (according to IEC 60304) - Fibers in tube 1-12

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

54 | Microduct MK-DX2/25

-100

TRANSPORT

Last mile connection outdoor

FTTH

OPERATION

Microduct Generation 1

3


microduct

MICRODUCT MK-LX4

MK-LX4

Cable structure (MK-LX4) 5. Water blocking yarns 1. HDPE outer jacket 6. Water blocking yarns 2. Loose tubes (PBT) on strand element with colored fibers in 7. Ripcord filling gel 3. Fillers 4. Central strength member (FRP)

1

2

3

4

5 6

7 Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LX4 Version

Fibers per tube

Fibers

Total elements

Active tubes

Fillers

Max. tensile load [N]

Nominal weight ±10% [kg/km]

Ø ± 5% [mm]

1T x 4F

4

4

6

1

5

4.2

8

2T x 4F

6

4

6

2

4

4.2

8

3T x 4F

12

4

6

3

3

4.2

9

4T x 4F

16

4

6

4

2

4.2

9

5T x 4F

20

4

6

5

1

4.2

10

6T x 4F

24

4

6

6

0

4.2

10

installation

operation

250

150

Applications Crush

[N/10 cm]

ÆÆ

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

500

Features ÆÆ

HDPE, UV stabilized outer jacket with low friction

Other fiber counts available on demand

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

Compatibility table

ÆÆ

PBT tubes containing up to 4 optical fibers

ÆÆ

Smallest outer diameter for blowing into 5.5 mm (ID) ducts

Direct burried ducts

3

2.1

-

5/3.5

5

3.5

-

7/5.5

7

5.5

10/8

10

8

12/10

12

10

14/12

14

12

MK-LX4

-

Fiber qty

4-24

Outer Ø [mm]

Inner Ø

7/3.5

7

3.5

-

7/3.8

7

3.8

-

7/4

7

4

-

10/5.5

10

5.5

12/8

12

8

14/10

14

10

Version

MK-LX4

[mm]

Operating temperature +100 +70°C +55°C

Fiber qty

4-24

Available colors

-30°C

T-Telecom (according to IEC 60304) - Fibers 1-12

1

2

3

4

Code Color

-40°C

T-Telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

red

green

blue

white

violet

orange

Code red

-15°C

TRANSPORT

3/2.1

[mm]

OPERATION

Inner Ø

[mm]

INSTALLATION

Outer Ø

Version

temperature [°C]

standard microduct

green

blue

white

Color

-100

*In case of lower fiber count some tubes can be replaced by fillers.

microduct MK-LX4 | 55


microduct

MICRODUCT MK-LXS6/7/8

MK-LXs6/7/8 Cable structure (MK-LXS6) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord

1

2

3

4

5 6

7 Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LXS6 Active tubes

Fillers

6T x 4F

24

4

6

6

0

5.3

18

6T x 6F

36

6

6

6

0

5.3

18

6T x 8F

48

8

6

6

0

5.3

19

6T x 10F

60

10

6

6

0

5.3

19

4T x 12F

48

10

6

4

2

5.3

20

6T x 12F

72

12

6

6

0

5.3

21

Max. tensile load [N] installation

650

operation

200

Applications Crush

[N/10 cm]

Nominal weight ±10% [kg/km]

Fibers

8T x 4F

32

4

8

8

0

6.2

28

8T x 6F

48

6

8

8

0

6.2

28

8T x 8F

64

8

8

8

0

6.2

29

8T x 10F

80

10

8

8

0

6.2

30

8T x 12F

96

12

8

8

0

6.2

31

Active tubes

Fillers

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Version

Fibers

12T x 4F

48

4

12

12

0

7.8

47

12T x 6F

72

6

12

12

0

7.8

48

12T x 8F

96

8

12

12

0

7.8

49

12T x 10F

120

10

12

12

0

7.8

50

12T x 12F

144

12

12

12

0

7.8

52

Total elements

Active tubes

Other fiber counts available on demand

56 | Microduct MK-LXs6/7/8

Flexible network design

ÆÆ

Distribution network

Features

Max. tensile load [N] installation

operation

Crush

ÆÆ

HDPE, UV stabilized outer jacket with low coefficient of friction

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

ÆÆ

PBT tubes containing up to 12 optical fibers

[N/10 cm]

Operating temperature 1200

350

Max. tensile load [N] installation

operation

+100 +100

500

MetroJET MK-LXS8 Fibers per tube

Metro networks

ÆÆ

temperature temperature [°C][°C]

Fillers

Ø ± 5% [mm]

Version

Total elements

Microduct cabling air-blowing system

ÆÆ

500

MetroJET MK-LXS7 Fibers per tube

ÆÆ

Crush [N/10 cm]

+70°C +70°C +55°C +55°C

-15°C -30°C -30°C -40°C

-100 -100

1500

550

500

TRANSPORT TRANSPORT

Total elements

Nominal weight ±10% [kg/km]

OPERATION OPERATION

Fibers

Ø ± 5% [mm]

INSTALLATION INSTALLATION

Version

Fibers per tube


microduct

MICRODUCT MK-LXS9/10

MK-LXs9/10 Cable structure (MK-LX9) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking tape on strand element 7. Ripcord

3

1

2

4

5 6

7

Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LXS9 Fillers

14T x 12F

168

12

18

14

4

8.7

53

16T x 12F

192

12

18

16

2

8.7

54

18T x 12F

216

12

18

18

0

8.7

55

installation

650

operation

200

Applications Crush

[N/10 cm]

24T x 12F

Fibers

288

Fibers per tube

Total elements

12

24

Active tubes

Other fiber counts available on demand

24

Fillers

0

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

500

Features

MetroJET MK-LXS10 Version

ÆÆ

Max. tensile load [N]

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

installation

operation

[N/10 cm]

9.4

72

1000

250

500

Crush

ÆÆ

HDPE, UV stabilized outer jacket with low coefficient of friction

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

ÆÆ

PBT tubes containing up to 12 optical fibers

Operating temperature +100 +100

+70°C +70°C +55°C +55°C

-15°C

TRANSPORT TRANSPORT

Active tubes

Max. tensile load [N]

OPERATION OPERATION

Total elements

Nominal weight ±10% [kg/km]

INSTALLATION INSTALLATION

Fibers

Ø ± 5% [mm]

temperature temperature [°C][°C]

Version

Fibers per tube

-30°C -30°C -40°C

-100 -100

microduct MK-LXS9/10 | 57


microduct

MICRODUCT MK-LX6

MK-LX6 Cable structure (MK-LX6) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord

1

2

3

4

5 6

7 Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LX6 Fibers

Total elements

Active tubes

Fillers

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

1T x 4F

4

4

6

1

5

5.6

28

1T x 6F

6

6

6

1

5

5.6

28

1T x 8F

8

8

6

1

5

5.6

28

2T x 6F

12

6

6

2

4

5.6

29

4T x 6F

24

6

6

4

2

5.6

29

6T x 6F

36

6

6

6

0

5.6

29

1T x 12F

12

12

6

1

5

5.6

30

2T x 12F

24

12

6

2

4

5.6

30

3T x 12F

36

12

6

3

3

5.6

30

4T x 12F

48

12

6

4

2

5.6

31

5T x 12F

60

12

6

5

1

5.6

32

6T x 12F

72

12

6

6

0

5.6

33

Max. tensile load [N] installation

operation

Applications Crush [N/10 cm]

ÆÆ

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

Features 750

250

1000

ÆÆ

HDPE, UV stabilized outer jacket with low friction

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

ÆÆ

PBT tubes containing 4-12 optical fibers

ÆÆ

Smallest diameter for blowing into 8 mm (ID) ducts

Operating temperature +100

Other fiber counts available on demand

1

2

3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

-15°C -30°C -40°C

T-Telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

red

green

blue

white

violet

orange

Code Color

*In case of lower fiber count some tubes can be replaced by fillers.

58 | Microduct MK-LX6

-100

TRANSPORT

1-12

OPERATION

T-Telecom (according to IEC 60304) - Fibers

temperature [°C]

+70°C +55°C

Available colors

INSTALLATION

Version

Fibers per tube


microduct

MICRODUCT MK-LX7

MK-LX7 Cable structure (MK-LX7) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers 4 in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord

1

3

2

5 6

7 Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LX7 Version

Fibers per tube

Fibers

Total elements

Active Fillers tubes

Ø ± 5% [mm]

Max. tensile load [N]

Nominal weight ±10% [kg/km]

8T x 4F

32

4

8

8

0

6.7

36

8T x 6F

48

6

8

8

0

6.7

37

8T x 8F

64

8

8

8

0

6.7

38

8T x 12F

96

12

8

8

0

6.7

39

installation

1600

operation

600

Applications Crush

[N/10 cm]

ÆÆ

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

1000

Features

Other fiber counts available on demand Available colors T-Telecom (according to IEC 60304) - Fibers 1-12

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

7

8

Code Color

ÆÆ

HDPE, UV stabilized outer jacket with low friction

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

ÆÆ

PBT tubes containing 4-12 optical fibers

ÆÆ

Smallest diameter for blowing into 8* and 10 mm (ID) ducts

* - blowing range may be lower

T-Telecom (according to IEC 60304) - Tubes 1

2

3

4

5

6

Operating temperature +100

green

blue

white

violet

orange

*In case of lower fiber count some tubes can be replaced by fillers.

grey

yellow

-15°C

TRANSPORT

red

temperature [°C]

Color

OPERATION

+70°C +55°C

Code

INSTALLATION

Tube

-30°C -40°C

-100

Microduct MK-LX7 | 59


microduct

MICRODUCT MK-LX8

MK-LX8 Cable structure 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord

1

2

3 4 5

6 Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1 7

Configuration

MetroJET MK-LX8 Version

Fibers per tube

Fibers

Total elements

Active tubes

Fillers

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

Applications Crush [N/10 cm]

ÆÆ

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

1T x 12F

12

12

12

1

11

8.6

53

2T x 12F

24

12

12

2

10

8.6

54

3T x 12F

36

12

12

3

9

8.6

55

4T x 12F

48

12

12

4

8

8.6

56

5T x 12F

60

12

12

5

7

8.6

57

6T x 12F

72

12

12

6

6

8.6

57

ÆÆ

HDPE, UV stabilized outer jacket with low friction

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

ÆÆ

PBT tubes containing 4-12 optical fibers

ÆÆ

Smallest diameter for blowing into 12 mm (ID) ducts

8T x 12F

96

12

12

8

4

8.6

59

12T x 12F

144

12

12

12

0

8.6

62

2500

600

1000

Other fiber counts available on demand

Features

Available colors Operating temperature

T-Telecom (according to IEC 60304) - Fibers 1

2

3

4

5

6

7

8

9

10

11

12

+100

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

7

8

9

10

11

12

T-Telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

-30°C

Code Color

-15°C -40°C

red

green

blue

white

violet

orange

*In case of lower fiber count some tubes can be replaced by fillers.

60 | Microduct MK-LX8

grey

yellow

brown

pink

black

aqua -100

TRANSPORT

red

temperature [°C]

Color

OPERATION

+70°C +55°C

Code

INSTALLATION

1-12


microduct

MICRODUCT MK-LX9

MK-LX9 Cable structure 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord

1

3

2

4

5 6

7 Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LX9 Total elements

Active tubes

Fillers

±10% [kg/km]

14T x 12F

168

12

18

14

4

9.2

62

16T x 12F

192

12

18

16

2

9.2

63

18T x 12F

216

12

18

18

0

9.2

64

Max. tensile load [N] installation

750

operation

250

Applications Crush [N/10 cm]

1000

ÆÆ

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

Other fiber counts available on demand

Features

Available colors T-Telecom (according to IEC 60304) - Fibers 1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

ÆÆ

PBT tubes containing up to 12 optical fibers

ÆÆ

Smallest diameter for blowing into 12 mm (ID) ducts

Operating temperature

T-Telecom (according to IEC 60304) - Tubes Tube

Loose tubes (and fillers), SZ stranded around the CSM

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

+100 +70°C +55°C INSTALLATION

Color

HDPE, UV stabilized outer jacket with low friction

ÆÆ

temperature [°C]

1-12

ÆÆ

-15°C

TRANSPORT

Fibers

Nominal weight

Ø ± 5% [mm]

OPERATION

Version

Fibers per tube

-30°C -40°C

-100

Microduct MK-LX9 | 61


microduct

MICRODUCT MK-LX11

MK-LX11 Cable structure 1. HDPE outer jacket 2. Fillers 3. Loose tubes (PBT) with colored fibers in filling gel 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord

1 2 3 4

5 6

7

Optimal Diameter

Low Friction

Blowing installation

Telecom

Microduct Generation 1

Configuration

MetroJET MK-LX11 Version

Fibers per tube

Fibers

Total elements

Active tubes

Fillers

Nominal weight

Ø ± 5% [mm]

±10% [kg/km]

20T x 12F

240

12

24

20

4

10.8

85

22T x 12F

264

12

24

22

2

10.8

86

24T x 12F

288

12

24

24

0

10.8

87

Max. tensile load [N] installation

900

operation

350

Applications Crush [N/10 cm]

1000

ÆÆ

Microduct cabling air-blowing system

ÆÆ

Metro networks

ÆÆ

Flexible network design

ÆÆ

Distribution network

Other fiber counts available on demand

Features

Available colors

ÆÆ

HDPE, UV stabilized outer jacket with low friction

T-Telecom (according to IEC 60304) - Fibers

ÆÆ

Loose tubes (and fillers), SZ stranded around the CSM

ÆÆ

PBT tubes containing up to 12 optical fibers

ÆÆ

Smallest outer diameter for blowing into 12 mm (ID) ducts

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Operating temperature

T-Telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

+100 +70°C +55°C

-15°C -30°C -40°C

-100

62 | Microduct MK-LX11

TRANSPORT

3

OPERATION

2

INSTALLATION

1

temperature [°C]

1-12


temperature [°C]

-5°C

-30°C -40°C

-100

TRANSPORT

OPERATION

INSTALLATION

Telecom Duct

+100

+70°C +55°C


telecom duct

TELECOM DUCT BDC-MSA

bdc-MSA

1

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. PET tape 4. Water blocking yarns on FRP 5. Central strength member (FRP) 6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord Basic Rodent Protection

Telecom

2 3

7 4

5

6 8

Duct

Configuration

telecom duct BDC-msa Version

Fibers

1T x 12F

12

1-6T x 4F

4-24

1T x 6F

6

2T x 6F

12

2T x 12F

24

Fibers per tube

Total elements

12

Ø ± 5% [mm]

Active tubes

Max. tensile load [N]

Nominal weight PE ±5% [kg/km]

8.2

installation

operation

1500

550

50

Applications Crush

[N/10 cm]

ÆÆ

Installation into existing ducts

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

6

1

4

6

1-6

8.2

50

1550

780

6

6

1

8.2

50

1550

780

6

6

2

8.2

50

1550

780

12

6

2

8.2

51

1500

550

ÆÆ

HDPE outer jacket

Features

4T x 6F

24

6

6

4

8.2

51

1550

780

ÆÆ

Optical fibers

3T x 12F

36

12

6

3

8.2

52

1500

550

ÆÆ

Jelly into the Loose tube

6T x 6F

36

6

6

6

8.2

53

1550

780

ÆÆ

4T x 12F

48

12

6

4

8.2

53

1500

550

Loose tubes (PBT Ø 1.8 mm) with filling compound

ÆÆ

PET tape to prevent moisture into the cable

5

8.2

54

1500

550

6

8.2

54

1500

550

8T x 4F

48

4

8

8

9.3

70

1650

750

8T x 12F

96

12

8

8

9.3

71

1620

750

11T x 12F

132

12

12

11

11.5

102

1620

850

12T x 12F

144

12

12

12

11.5

104

1620

850

13T x 12F

156

12

14

13

12.6

126

2100

850

14T x 12F

168

12

14

14

12.6

126

2100

850

Operating temperature +100 +70°C

Other fiber counts available on demand

-40°C

T-Telecom (according to IEC 60304) - Fibers

-100

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

t-telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

-5°C -20°C

Available colors 1-12

+55°C

*In case of lower fiber count some tubes can be replaced by fillers.

64 | telecom duct BDC-MSA

TRANSPORT

6 6

OPERATION

12 12

INSTALLATION

60 72

temperature [°C]

5T x 12F 6T x 12F

1500


telecom duct

TELECOM BDC-MIB

BDC-MIB

1

Cable structure

Basic Rodent Protection

Telecom

1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)

Duct

6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord

2 5

3

4

7 6 8

Configuration

telecom duct BDC-MIB Version

Fibers

Fibers per tube

Total elements

Ø ± 5% [mm]

Active tubes

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

Applications Crush [N/10 cm]

ÆÆ

For installation into existing duct or directly buried

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

1-6T x 6F

6-36

6

6

1-6

8.8

63

2800

1500

1-6T x 12F

12-72

12

6

1-6

8.8

66

2800

1000

8T x 6F

48

6

8

8

10.0

77

2800

1500

8T x 12F

96

12

8

8

10.0

82

2800

1000

12T x 12F

144

12

12

12

12.2

117

2800

1000

ÆÆ

FRP strength and anti-buckling rod

16-18T x 12F

192-216

12

18

16-18

12.6

122

2800

1000

ÆÆ

Dry yarns to prevent moisture into the cable

20-24T x 12F

240-288

12

24

20-24

14.2

156

2800

1000

ÆÆ

Loose tubes (PBT Ø 1,8mm) with filling compound

ÆÆ

Optical fibers

ÆÆ

Fibreglass yarns as tensile elements

ÆÆ

UV stabilized HDPE jacket

Features

1500

Other fiber counts available on demand Available colors T-Telecom (according to IEC 60304) - Fibers 1

2

3

4

5

6

7

8

9

10

11

12

Operating temperature

Code blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

7

8

9

10

11

12

t-telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

PE Black RAL 9005

aqua

+70°C +55°C

-15°C

TRANSPORT

green

OPERATION

red

temperature [°C]

Color

+100

INSTALLATION

1-12

-40°C

-100

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

telecom duct BDC-MIB | 65


telecom duct

TELECOM DUCT BDC-C0

BDC-c0

1

Cable structure

Basic Rodent Protection

Telecom

6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord

1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)

Duct

2 5

3

4

7 6 8

Configuration

telecom duct bdc-c0 Version

Fibers per tube

Fibers

Total elements

Ø ± 5% [mm]

Active tubes

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

Applications Crush [N/10 cm]

ÆÆ

Installation into existing ducts

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Basic rodent protection

1T x 4F

4

4

6

1

1T x 6F

6

6

6

2

2T x 6F

12

6

6

2

4T x 6F

24

6

6

4

1T x 12F

12

12

6

1

2T x 12F

24

12

6

2

ÆÆ

FRP strength and anti-buckling element

3T x 12F

36

12

6

3

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.0 mm)

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as tensile elements

ÆÆ

UV stabilized HDPE jacket

10.0

71

2100

1300

10.0

71

2100

1300

Features

1000

4T x 12F

48

12

6

4

5T x 12F

60

12

6

5

6T x 12F

72

12

6

6

8T x 12F

96

12

8

8

11.3

97

2100

1000

12T x 12F

144

12

12

12

13.8

144

2200

1100

16T x 12F

192

12

18

16

14.2

148

2200

1100

18T x 12F

216

12

18

18

14.2

150

2200

1100

24T x 12F

288

12

24

24

16.2

190

2500

1200

2000

Operating temperature +100 +70°C +55°C temperature [°C]

Other fiber counts available on demand Available colors T-Telecom (according to IEC 60304) - Fibers 1-12

1

2

3

4

5

6

7

8

9

10

11

12 -40°C

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

t-telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

-15°C

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

66 | telecom duct BDC-C0

-100

TRANSPORT

2000

OPERATION

74

INSTALLATION

10.0


telecom duct

TELECOM BDC-CI

BDC-CI

1

Cable structure

Basic Rodent Protection

Telecom

1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)

Duct

6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord

2 5

3

4

7 6

Configuration

8

telecom duct bdc-cI Max. tensile load [N]

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

installation

operation

10.0

74

2800

1700

10.0

74

2800

1700

4

4

6

1

1T x 6F

6

6

6

1

2T x 6F

12

6

6

2

1T x 12F

12

12

6

1

10.0

73

2700

1200

4Tx 6F

24

6

6

4

10.0

74

2800

1600

2T x 12F

24

12

6

2

10.0

75

2700

1200

3Tx 12F

36

12

6

3

4T x 12F

48

12

6

4

10.0

82

2700

1200

6T x 12F

72

12

6

6

8T x 12F

96

12

8

8

11.4

101

2700

1200

12T x 12F

144

12

12

12

13.8

146

13T x 12F

156

12

18

13

14.2

149

14T x 12F

168

12

18

14

14.2

150

15T x 12F

180

12

18

15

14.2

151

16T x 12F

192

12

18

16

14.2

152

17T x 12F

204

12

18

17

14.2

153

18T x 12F

216

12

18

18

14.2

154

24T x 12F

288

12

24

24

16.3

191

2700

2900

Applications

2000

1200

3

4

5

Fully dielectric cable

ÆÆ

Basic rodent protection

ÆÆ

FRP strength and anti-buckling element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.0 mm)

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as tensile elements

ÆÆ

UV stabilized HDPE jacket

+100

2900

+70°C +55°C

1400 temperature [°C]

6

7

8

9

10

11

-15°C

12 -40°C

Code Color

ÆÆ

Operating temperature

T-Telecom (according to IEC 60304) - Fibers 2

High tensile and crush performance

1400

Available colors 1

Installation into existing ducts

ÆÆ

Features

Other fiber counts available on demand

1-12

ÆÆ

TRANSPORT

1T x 4F

Crush [N/10 cm]

OPERATION

Fibers

INSTALLATION

Version

Fibers per tube

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

7

8

9

10

11

12

-100

t-telecom (according to IEC 60304) - Tubes Tube

1

Code PE Black Color

red

2

3

RAL 9005 green

4

5

6

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

telecom duct BDC-CI | 67


telecom duct

TELECOM DUCT BDC-CK

BDC-ck

1

Cable structure

Basic Rodent Protection

Telecom

6. Loose tubes (PBT) with colored fibers 3 in filling gel 7. Fillers 7 8. Ripcord

1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)

Duct

2 5 4

6

Configuration

8

telecom duct bdc-ck Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight

Max. tensile load [N]

Version

Fibers

Fibers per tube

1T x 4F

4

4

6

1

10.1

77

1T x 6F

6

6

6

1

10.1

78

1T x 8F

8

8

6

1

10.1

79

1T x 10F

10

10

6

1

10.1

80

1T x 12F

12

12

6

1

10.2

81

4100

2000

2T x 6F

12

6

6

2

10.1

78

4000

2400

2T x 12F

24

12

6

2

10.2

81

4100

2000

4T x 6F

24

6

6

4

10.1

79

4000

2400

3T x 12F

36

12

6

3

10.2

82

4100

2000

6T x 6F

36

6

6

6

10.1

82

4000

2400

±10% [kg/km]

installation

operation

Crush [N/10 cm]

Applications 2400

12

6

4

10.2

83

4100

2000

8T x 6F

48

6

8

8

11.4

98

4100

2700

5T x 12F

60

12

6

5

10.2

84

6T x 12F

72

12

6

6

10.2

85

4100

2000

96

12

8

8

11.4

104

4200

2300

144

12

12

12

13.9

151

4200

2000

16T x 12F

192

12

18

16

14.1

191

18T x 12F

216

12

18

18

14.1

191

4100

1800

24T x 12F

288

12

24

24

15.9

240

4000

1900

2000

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

t-telecom (according to IEC 60304) - Tubes 1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

68 | telecom duct BDC-Ck

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.0 mm)

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as tensile elements

ÆÆ

UV stabilized HDPE jacket

+70°C +55°C

Code

Color

FRP strength and anti-buckling element

ÆÆ

+100

T-Telecom (according to IEC 60304) - Fibers

Tube

ÆÆ

Operating temperature

Available colors

Color

Basic rodent protection

Features

Other fiber counts available on demand

1-12

Fully dielectric cable

ÆÆ

temperature [°C]

8T x 12F 12T x 12F

High tensile and crush performance

ÆÆ

-15°C -40°C

-100

TRANSPORT

48

Installation into existing ducts

ÆÆ

OPERATION

4T x 12F

ÆÆ

INSTALLATION

4000


telecom duct

TELECOM DUCT DDC-SI

ddc-SI

1

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. HDPE inner jacket 4. Water blocking yarns 5. Central strength member (FRP) 6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcords High Rodent Protection

Telecom

Duct

2 3

7

4 5

6

Direct buried 8

Configuration

telecom duct DDC-SI Version

Fibers per tube

Fibers

Total elements

Ø ± 5% [mm]

Active tubes

Nominal weight ±10% [kg/km]

Max. tensile load [N] allowed

static

1-6T x 4F

4 - 24

4

6

1-6

9.3

67

2800

800

8T x 4F

32

4

8

8

10.3

83

2700

650

1-6T x 6F

6 - 36

6

6

1-6

9.4

68

2800

800

Applications Crush [N/10 cm]

ÆÆ

Installation into existing ducts

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

High rodent protection

8T x 6F

48

6

8

8

10.4

85

2800

800

1-6T x 12F

12 - 72

12

6

1-6

9.4

73

2700

650

8T x 12F

96

12

8

8

10.4

88

2700

670

ÆÆ

FRP strength and anti-buckling element

670

ÆÆ

Optical fibers

ÆÆ

Loose tube (PBT Ø 1.6mm) with filling compound

ÆÆ

Dry yarns to prevent moisture into the cable

Available colors

ÆÆ

T-Telecom (according to IEC 60304) - Fibers

Fiberglass yarns as tensile and water absorbent elements

ÆÆ

Double HDPE jacket

ÆÆ

LSOH, PA etc. outer jacket option

12T x 12F

144

12

12

12

12.3

122

2800

2000

Features

Other fiber counts available on demand

1-12

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code

Operating temperature +100

t-telecom (according to IEC 60304) - Tubes 3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

+70°C +55°C

-15°C

TRANSPORT

2

OPERATION

1

temperature [°C]

Tube

INSTALLATION

Color

-40°C

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

-100

telecom duct DDC-SI | 69


telecom duct

TELECOM DUCT DDC-CI

ddc-ci

1

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. HDPE inner jacket 4. Water blocking yarns 5. Central strength member (FRP)

6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcords

2 3

7

4 5

6 High Rodent Protection

Telecom

Hi-crush

Direct buried

Duct

8 Configuration

telecom duct DDC-ci Version

Fibers per tube

Fibers

Total elements

Ø ± 5% [mm]

Active tubes

Nominal weight ±10% [kg/km]

Max. tensile load [N] allowed

static

1-6T x 4F

4 - 24

4

6

1-6

11.7

73

4400

2600

1-6T x 6F

6 - 36

6

6

1-6

11.7

73

4400

2600

1-6T x 12F

12 - 72

12

6

1-6

11.8

105

4100

2000

Applications Crush [N/10 cm]

ÆÆ

Installation into existing ducts

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

High rodent protection

8T x 6F

48

6

8

8

13.0

124

4100

2300

8T x 12F

96

12

8

8

13.0

128

4100

2000

12T x 12F

144

12

12

12

15.5

180

4600

2200

ÆÆ

FRP strength and anti-buckling element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.0 mm)

ÆÆ

Dry yarns and tape to prevent moisture into the cable

ÆÆ

Glass yarns as tensile elements

ÆÆ

Double HDPE jacket

ÆÆ

LSOH, PA etc. outer jacket option

16T x 12F

192

12

16

16

15.9

185

4600

2200

18T x 12F

216

12

18

18

15.9

187

4600

2200

24T x 12F

288

12

24

24

17.9

193

5000

2600

Features

3500

Other fiber counts available on demand

Available colors

Operating temperature

T-Telecom (according to IEC 60304) - Fibers 4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

t-telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

7

8

9

10

11

12

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

Code Color

*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers

70 | telecom duct DDC-ci

+100 +70°C +55°C

-15°C -40°C

-100

TRANSPORT

3

OPERATION

2

INSTALLATION

1

temperature [°C]

1-12


Telecom Aerial


telecom aerialAero-DF03 Cable structure 1. PE jacket 2. Ripcord 3. Water blocking yarns

Last mile connection outdoor

Aerial

1

4. Central Loose tube (PBT) with 250 µm colored fibers in filling gel 5. FRP strength member

2 4

3

5

Telecom

Hi-crush

FTTH

TELECOM AERIAL Aero-DF03

Cable variants Version

AERO-DF03

AERO-DF03

Fiber count

1-12

16-24

Cable dimensions [mm]

8.3 x 4.6 (±3%)

8.7 x 5.0 (-3%)

Cable weight [kg/km]

37

38

Max. installation tension[N]

1300

1300

Applications

Mechanical and enviromental characteristics

ÆÆ

Installation on poles or walls

ÆÆ

Can be installed in pipelines

ÆÆ

Fully dielectric cable

Parameter Crush performance

5000 N

Bending performance

10 cycles [20 x D]

Water Penetration

3 m sample, 1 m head, 24 h

Features ÆÆ

Loose tube with filling compound (PBT)

ÆÆ

Up to 24 fibers in a cable

Available colors

ÆÆ

Two FRP strength elements

T-Telecom (according to IEC 60304) - Fibers in tube

ÆÆ

Dry yarns to prevent moisture into cable

ÆÆ

Ripcord yarns For easy jacket removal

ÆÆ

PE UV resistant Jacket

1-12

1

2

3

4

5

6

7

8

9

10

11

12

Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

Code

Operating temperature +100

Code white

violet

orange

grey

yellow

brown

pink

natural

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm NESC Light

aqua

-15°C

TRANSPORT

blue

OPERATION

green

INSTALLATION

red

temperature [°C]

Color

+70°C +55°C

span: 120 m

-40°C

sag: 2.4 m

-100

NSC Medium span: 70 m

sag: 1.4 m

NESC Heavy span: 40 m

sag: 0.8 m

72 | telecom AERIAL Aero-DF03

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


telecom aerialAero-AS02 2.0 mm

TELECOM AERIAL Aero-AS02 2.0 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

6

2 3 4

7

5

8

Configuration

AERO-AS02 PBT TUBES 2.0 mm Version 1-6T x 6F

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Tensile load [N] allowed

static

6 – 36

6

6

1–6

10.0

73

2200

1200

1-6T x 12F 12 – 72

12

6

1–6

10.0

75

2100

1000

8T x 12F

96

12

8

8

11.3

98

2200

1100

12T x 12F

144

12

12

12

13.8

143

2100

1000

Applications Crush

[N/10 cm]

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

2000

Other fiber counts available on demand

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.0 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Optical fibers

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction) NESC Light span: 130 m

sag: 2.6 m

NSC Medium span: 85 m

PE Black RAL 9005

sag: 1.7Grey m LSOH RAL 7022 LSOH Light Grey RAL 7037

NESC Heavy span: 45 m

sag: 0.9 m

telecom AERIAL AERO-AS02 2.0 mm | 73


telecom aerialAero-AS03 2.0 mm

TELECOM AERIAL Aero-AS03 2.0 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

2

6

3 4 7

5

8

Configuration

AERO-AS02 PBT TUBES 2.0 mm Version

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

1-6T x 6F

6-36

6

6

1-6

10.0

1-6T x 12F

12-72

12

6

1-6

8T x 12F

96

12

8

12T x 12F

144

12

12

Tensile load [N] allowed

static

75

3200

1800

10.1

77

3100

1500

8

11.3

100

3100

1500

12

13.8

146

3100

1500

Crush

[N/10 cm]

2000

Applications ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

Other fiber counts available on demand Available colors Features

T-Telecom (according to IEC 60304) - Fibers 3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

t-telecom (according to IEC 60304) - Tubes Tube

1

2

3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

*In case of lower fiber count some tubes can be replaced by fillers.

black

aqua

ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.0 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Optical fibers

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

Operating temperature

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70°C temperature [°C]

span: 190 m

sag: 3.8 m

NSC Medium span: 130 m

sag: 2.6 m

NESC Heavy span: 75 m

sag: 1.5 m

74 | telecom AERIAL AERO-AS03 2.0 mm

+55°C TRANSPORT

2

OPERATION

1

INSTALLATION

1-12

-15°C -40°C

PE Black RAL 9005

-100

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


telecom aerialAero-AS03 2.5 mm

TELECOM AERIAL Aero-AS03 2.5 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

2

6

3 4 7

5

8

Configuration

AERO-AS03 PBT TUBES 2.5 mm Version

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

11.4

97

3300

2200

1-6T x 12F

12-72

12

6

1-6

11.4

98

3200

2100

8T x 12F

96

12

8

8

13.0

127

3200

2100

12T x 12F

144

12

12

12

16.1

193

3300

2200

Applications Crush

[N/10 cm]

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

3000

Other fiber counts available on demand

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.0 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Optical fibers

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70°C

NSC Medium span: 140 m

PE Black RAL 9005

sag: 2.8 m LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

TRANSPORT

OPERATION

+55°C INSTALLATION

sag: 3.8 m

temperature [°C]

span: 190 m

-15°C -40°C

-100

NESC Heavy span: 80 m

sag: 1.6 m

telecom AERIAL AERO-AS03 2.5 mm | 75


telecom aerialAero-AS04 2.0 mm

TELECOM AERIAL Aero-AS04 2.0 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

2

6

3 4 7

5

8

Configuration

AERO-AS04 PBT TUBES 2.0 mm Version

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1T x 12F

12

12

6

1

10,1

75

4000

2000

2T x 6F

12

6

6

2

10,1

75

4100

2400

2T x 12F

24

12

6

2

10,1

76

4000

2000

4T x 6F

24

6

6

4

10,1

76

4100

2400

3T x 12F

36

12

6

3

10,1

80

4000

2000

6T x 6F

36

6

6

6

10,1

76

4100

2400

4T x 12F

48

12

6

4

10,1

80

4000

2000

8T x 6F

48

6

8

8

11.3

97

4200

2500

6T x 12F

72

12

6

6

10,1

82

4000

2000

8T x 12F

96

12

8

8

11,4

103

4200

12T x 12F

144

12

12

12

13,9

149

4100

Other fiber counts available on demand

Applications Crush

[N/10 cm]

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

Features

2000 ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.0 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

2100

ÆÆ

Optical fibers

2000

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NSC Light

+70°C

NSC Medium span: 170 m

PE Black RAL 9005

TRANSPORT

OPERATION

+55°C INSTALLATION

sag: 5.0 m

temperature [°C]

span: 250 m

-15°C -40°C

-100

LSOH RAL 7022PELSOH BlackLight RAL 9005 Grey RAL 7037 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 sag: 3.4Grey m

NSC Heavy span: 95 m

sag: 1.9 m

76 | telecom AERIAL AERO-AS04 2.0 mm


telecom aerialAero-AS04 2.5 mm

TELECOM AERIAL Aero-AS04 2.5 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

2

6

3 4 7

5

8

Configuration

AERO-AS04 PBT TUBES 2.5 mm Version

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

11.4

98

4200

2900

1-6T x 12F

12-72

12

6

1-6

11.4

99

4100

2600

8T x 12F

96

12

8

8

13.1

128

4200

2800

12T x 12F

144

12

12

12

16.2

194

4100

2700

Applications Crush

[N/10 cm]

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

3000

Other fiber counts available on demand

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.0 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Optical fibers

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70°C

NSC Medium span: 190 m

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 sag: 3.8 m

TRANSPORT

OPERATION

+55°C INSTALLATION

sag: 5.2 m

temperature [°C]

span: 260 m

-15°C -40°C

-100

NESC Heavy span: 110 m

sag: 2.2 m

telecom AERIAL AERO-AS04 2.5 mm | 77


telecom aerialAero-AS06 2.0 mm

TELECOM AERIAL Aero-AS06 2.0 mm 1

Cable structure

Aerial

Telecom

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

6. Fillers 7. Water blocking tape 8. Ripcord

2

6

3 4 7

5

8

Configuration

AERO-AS06 PBT TUBES 2.0 mm Qnt Version Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

10.2

82

6100

3600

1-6T x 12F

12

12

6

1-6

10.3

88

6200

3000

8T x 12F

96

12

8

8

11.5

110

6200

2800

12T x 12F

144

12

12

12

13.9

154

6100

3000

Applications Crush

[N/10 cm]

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

2000

Features

Other fiber counts available on demand ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.0 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Optical fibers

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70°C

NSC Medium

NESC Heavy span: 140 m

sag: 2.8 m

78 | telecom AERIAL Aero-AS06 2.0 mm

TRANSPORT

-15°C -40°C

span: 250 m

sag: 5.0 m

OPERATION

sag: 7.2 m

+55°C INSTALLATION

temperature [°C]

span: 360 m

PE Black RAL 9005

-100

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


telecom aerialAero-AS06 2.5 mm

TELECOM AERIAL Aero-AS06 2.5 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

2

6

3 4 7

5

8

Configuration

AERO-AS06 PBT TUBES 2.5 mm Version

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

11.6

101

6100

4200

1-6T x 12F

12-72

12

6

1-6

11.6

104

6300

4100

8T x 12F

96

12

8

8

13.2

132

6100

4000

12T x 12F

144

12

12

12

16.2

198

6100

4000

Applications Crush

[N/10 cm]

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

3000

Other fiber counts available on demand

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

Loose tube (PBT Ø 2.5 mm) with filing compound

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Optical fibers

ÆÆ

Fillers (if applicable)

ÆÆ

Water-swellable tape

ÆÆ

Aramid yarns as strain relief and water absorbent

ÆÆ

UV stabilized HDPE jacket

Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

+100

NESC Light

+70°C

NSC Medium span: 270 m

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 sag: 5.4 m

TRANSPORT

OPERATION

+55°C INSTALLATION

sag: 7.4 m

temperature [°C]

span: 370 m

-15°C -40°C

-100

NESC Heavy span: 150 m

sag: 3.0 m

telecom AERIAL Aero-AS06 2.5 mm | 79


telecom aerialAero-AS09 2.5 mm

TELECOM AERIAL Aero-AS09 2.5 mm 1

Cable structure

Aerial

Telecom

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

6. Fillers 7. Water blocking tape 8. Ripcord

2

6

3 4 7

5

8

Configuration

AERO-AS09 PBT TUBES 2.5 mm Qnt Version Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

11.6

101

9300

6600

1-6T x 12F

12-72

12

6

1-6

11.7

104

9200

6000

8T x 12F

96

12

8

8

13.2

138

9200

6100

12T x 12F

144

12

12

12

16.2

203

9200

6100

Applications Crush

[N/10 cm]

3000

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

ÆÆ

UV resistant

Other fiber counts available on demand

Features ÆÆ

FRP strength and anti-buckling element Ø 2.5 mm

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.5 mm)

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Dry yarns to prevent moisture into cable

ÆÆ

Aramid yarns as tensile elements

Operating temperature +100 +70°C

sag: 10.6 m

TRANSPORT

span: 530 m

+55°C OPERATION

temperature [°C]

NESC Light

INSTALLATION

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

-15°C -40°C

NSC Medium span: 400 m

-100

sag: 8.0 m

NESC Heavy span: 230 m

sag: 4.6 m

80 | telecom AERIAL Aero-AS09 2.5 mm

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


telecom aerialAero-AS12 2.5 mm

TELECOM AERIAL Aero-AS12 2.5 mm 1

Cable structure

Aerial

Telecom

6. Fillers 7. Water blocking tape 8. Ripcord

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

2

6

3 4 7

5

8

Configuration

AERO-AS12 PBT TUBES 2.5 mm Version

Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

11.7

106

12700

9000

1-6T x 12F

12-72

12

6

1-6

11.8

110

12500

8000

8T x 12F

96

12

8

8

13.3

143

12200

7800

12T x 12F

144

12

12

12

16.3

208

12100

8000

Applications Crush

[N/10 cm]

3000

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

ÆÆ

UV resistant

Other fiber counts available on demand Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.5 mm)

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Dry yarns to prevent moisture into cable

ÆÆ

Aramid yarns as tensile elements

Operating temperature +100 +70°C

sag: 14 m

TRANSPORT

OPERATION

span: 700 m

+55°C INSTALLATION

NESC Light

temperature [°C]

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

-15°C -40°C

NSC Medium span: 530 m

-100

PE Black RAL 9005

sag: 10.6 m LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

NESC Heavy span: 310 m

sag: 6.2 m

telecom AERIAL Aero-AS12 2.5 mm | 81


telecom aerialAero-AS14 2.5 mm

TELECOM AERIAL Aero-AS14 2.5 mm 1

Cable structure

Aerial

Telecom

1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns

FTTH

6. Fillers 7. Water blocking tape 8. Ripcord

2

6

3 4 7

5

8

Configuration

AERO-AS14 PBT TUBES 2.5 mm Qnt Version Fibers

Fibers per tube

Total elements

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] installation

operation

1-6T x 6F

6-36

6

6

1-6

11.8

109

14400

10100

1-6T x 12F

12-72

12

6

1-6

11.8

113

14500

9400

8T x 12F

96

12

8

8

13.4

147

14200

9100

12T x 12F

144

12

12

12

16.4

211

14000

9200

Applications Crush

[N/10 cm]

3000

ÆÆ

Duct & pole mount

ÆÆ

High tensile and crush performance

ÆÆ

Fully dielectric cable

ÆÆ

Self-supported aerial cable with aramid reinforcements

ÆÆ

UV resistant

Other fiber counts available on demand

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Optical fibers

ÆÆ

Loose tube with filling compound (PBT Ø 2.5 mm)

ÆÆ

6-12 elements SZ stranded cable core

ÆÆ

Dry yarns to prevent moisture into cable

ÆÆ

Aramid yarns as tensile elements

Operating temperature +100 +70°C

sag: 16.0 m

TRANSPORT

span: 800 m

+55°C OPERATION

temperature [°C]

NESC Light

INSTALLATION

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)

-15°C -40°C

NSC Medium span: 600 m

-100

sag: 12.0 m

NESC Heavy span: 350 m

sag: 7.0 m

82 | telecom AERIAL AERO-AS14 2.5 mm

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


Special Cable Designs


special design FTTA-DAC

special design FTTA-DAC 1

Cable structure 1. Outer jacket PE 2. Fiberglass yarns 3. Loose tube (PBT) with colored fibers in filling gel 4. Ripcords 5. Embedded strength members (FRP)

2

5

3

4

FTTA

Hi-crush

Aerial

Compact design

Configuration

FTTA-DAC Version

Fibers

Fibers per tube

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

1T x 2F

2

2

5.8

31

1T x 4F

4

4

5.8

31

1T x 6F

6

1T x 8F

8

8

5.8

32

1T x 12F

12

12

5.8

32

1T x 24F

24

24

6.3

38

6

5.8

Max. tensile load [N] installation

operation

800 (ε=0.33%)

31

Crush

[N/10 cm]

250

1200 (ε=0.50%)

3500

Applications ÆÆ

Fiber to the antenna system ( FTTA)

ÆÆ

Optical access cable with fiber glass yarns reinforcement

ÆÆ

Direct buried construction

ÆÆ

Fully dielectric cable

ÆÆ

Last mile connection

Features Available colors T-Telecom (according to IEC 60304) - Fibers 1

2

3

4

5

6

7

8

9

10

11

12

Code Color

red

green

blue

white

violet

orange

grey

yellow

brown

pink

black

aqua

13-24

13

14

15

16

17

18

19

20

21

22

23

24

red

green

blue

white

violet

orange

grey

yellow

brown

pink

natural

aqua

Fiberglass yarns as water-blocking and strain relief elements

ÆÆ

Loose tube (PBT) with filing compound

ÆÆ

Optical fibers

ÆÆ

Embedded strength members (FRP)

Operating temperature

Code

+100 +70°C

TRANSPORT

+50°C OPERATION

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

temperature [°C]

Color

INSTALLATION

1-12

ÆÆ

-15°C -45°C

-100

PE Black RAL 9005

84 | special design FTTA-DAC

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


hybrid power+fo

BDC-CIP 1.5 mm2

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-CIP 1

5. Water blocking tape 6. Central strength member (FRP) 7. 1.5 mm2 Cu – insulated copper wire 8. Ripcord

2 3 5 4 7 6

Duct

FTTH

Basic Rodent Protection

8

Hybrid FO + Power

Configuration

BDC-CIP 1.5 mm2 Version

Fibers

Fibers Total per elements tube

Active tubes

Ø ± 5% [mm]

Nominal weight ±10% [kg/km]

Max. tensile load [N] allowed

static

Applications Crush

[N/10 cm]

ÆÆ

Installation into existing ducts or directly buried

ÆÆ

High tensile and crush performance

1T x 12F +2x1.5 mm2

12

12

6

1

10.7

127

2700

1300

1T x 12F +4x1.5 mm2

12

12

6

1

10.7

170

2700

1300

2T x 12F +1x1.5 mm2

24

12

6

2

10.7

107

2700

1300

2T x 12F +2x1.5 mm2

24

12

6

2

10.7

128

2700

1300

ÆÆ

FRP strength and anti-buckling element

2T x 12F +4x1.5 mm2

ÆÆ

Loose tube with filling compound (PBT Ø 2.2mm)

24

12

6

2

10.7

171

2700

1300

ÆÆ

Tubes with copper core

3T x 12F +2x1.5 mm2

36

12

6

3

10.7

129

2700

1300

ÆÆ

Dry yarns to prevent moisture into the cable

ÆÆ

UV stabilized HDPE jacket

4T x 12F +2x1.5 mm2

48

12

6

4

10.7

130

2700

1300

ÆÆ

LSOH, PA etc Jacket option

1T x 12F +6x1.5 mm2

12

12

8

1

12.1

231

2700

1300

2T x 12F +6x1.5 mm2

24

12

8

2

12.1

232

2700

1300

3T x 12F +4x1.5 mm2

36

12

8

3

12.1

190

2700

1300

4T x 12F +4x1.5 mm2

48

12

8

4

12.1

191

2700

1300

Technical copper wire characteristics Max DC resistance

12,1±0,2 Ω/km@20°C

Electric strength

3400 V DC/1 minute

Current carrying capacity

7A

Operating voltage

65V AC/DC

Conductor material

Bare copper

PE Blackcross RALsection 9005 Conductor

Operating temperature +100 +70°C

TRANSPORT

OPERATION

+55°C INSTALLATION

2700

temperature [°C]

Other fiber and copper wire counts available on demand

Features

-15°C -40°C

-100

LSOH 1,5mm2Grey RAL 7022 LSOH Light Grey RAL 7037

Insulated conductor dia.

2,2mm

Insulation material

PVC

hybrid cables BDC-CIP | 85


hybrid power+fo

BDC-CIP 0.5 mm2 H05V-U

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-CIP 1

5. Water blocking tape 6. Central strength member (FRP) 7. 0.5 mm2 Cu – insulated copper wire 8. Ripcord

2 3 5 4 7 6

Duct

FTTH

Basic Rodent Protection

8

Hybrid FO + Power

Configuration

BDC-CIP 0.5 mm2 H05V-U Max. tensile load [N] allowed

static

1T x 12F +2x0.5 mm2

12

12

6

1

10.1

89

2700

1000

1T x 12F +4x0.5 mm2

12

12

6

1

10.1

105

2700

1000

1T x 12F +5x0.5 mm2

12

12

6

1

10.1

113

2700

1000

2T x 12F +2x0.5 mm2

24

12

6

2

10.1

90

2700

1000

2T x 12F +4x0.5 mm2

24

12

6

2

10.1

106

2700

1000

3T x 12F +2x0.5 mm2

36

12

6

3

10.1

91

2700

1000

4T x 12F +2x0.5 mm2

48

12

6

4

10.1

92

2700

1000

5T x 12F +1x0.5 mm2

60

12

6

5

10.1

85

2700

1000

1T x 12F +6x0.5 mm2

12

12

8

1

11.4

127

2800

1100

2T x 12F +6x0.5 mm2

24

12

8

2

11.4

128

2800

1100

4T x 12F +4x0.5 mm2

48

12

8

4

11.4

120

2800

1100

Other fiber and copper wire counts available on demand

Technical copper wire characteristics Max DC resistance

36,0 Ω/km@20°C

Conductor material

Bare copper

Conductor cross section

0.5 mm2

Insulated conductor dia.

2.0 mm

Insulation material

PVC

[N/10 cm]

ÆÆ

For installation into existing duct or directly buried

ÆÆ

High tensile and crush performance

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Insulated copper cores 0.5 mm2 (Ø 2.0 mm)

ÆÆ

Loose tubes with filling compound (PBT Ø 2.0 mm)

ÆÆ

Tape and dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as strain relief elements

ÆÆ

UV stabilized HDPE outer jacket

ÆÆ

Other outer jackets materials available

2700

Operating temperature +100 +70°C +55°C

-15°C -40°C

-100

PE Black RAL 9005

86 | hybrid cables BDC-CIP

Applications Crush

TRANSPORT

Nominal weight ±10% [kg/km]

OPERATION

Ø ± 5% [mm]

INSTALLATION

Fibers

Active tubes

temperature [°C]

Version

Fibers Total per elements tube

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037


BDC-CIP 0.75 mm2 H05V-U

hybrid power+fo

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-CIP 1

5. Water blocking tape 6. Central strength member (FRP) 7. 0.75 mm2 Cu – insulated copper wire 8. Ripcord

2 3 5 4 7 6

Basic Rodent Protection

Duct

FTTH

8

Hybrid FO + Power

Configuration

BDC-CIP 0.75 mm2 H05V-U Nominal weight ±10% [kg/km]

Max. tensile load [N] allowed

static

1T x 12F +2x0.75 mm2

12

12

6

1

10.7

99

2700

1300

1T x 12F +4x0.75 mm2

12

12

6

1

10.7

114

2700

1300

2T x 12F +2x0.75 mm2

24

12

6

2

10.7

100

2700

1300

2T x 12F +4x0.75 mm2

24

12

6

2

10.7

115

2700

1300

3T x 12F +2x0.75 mm2

36

12

6

3

10.7

101

2700

1300

4T x 12F +2x0.75 mm2

48

1T x 12F +6x0.75 mm2

12

12

8

1

12.1

147

2700

1300

2T x 12F +6x0.75 mm2

24

12

8

2

12.1

148

2700

1300

3T x 12F +4x0.75 mm2

36

12

8

3

12.1

134

2700

1300

4T x 12F +4x0.75 mm2

48

12

8

4

12.1

135

2700

1300

Applications Crush

[N/10 cm]

ÆÆ

For installation into existing duct or directly buried

ÆÆ

High tensile and crush performance

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Insulated copper cores 0.75mm2 (Ø 2.2mm)

ÆÆ

Loose tubes with filling compound (PBT Ø 2.2mm)

ÆÆ

Tape and dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as strain relief elements

ÆÆ

UV stabilized HDPE outer jacket

ÆÆ

Other outer jackets materials available

2700 6

4

10.7

102

2700

1300

Other fiber and copper wire counts available on demand

Technical copper wire characteristics Max DC resistance

24.0 Ω/km@20°C

Conductor material

Bare copper

Conductor cross section

0.75 mm2

Insulated conductor dia.

2.2 mm

Insulation material

PVC

PE Black RAL 9005

Operating temperature +100 +70°C +55°C INSTALLATION

12

TRANSPORT

Ø ± 5% [mm]

OPERATION

Fibers

Active tubes

temperature [°C]

Version

Fibers Total per elements tube

-15°C -40°C

-100

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

hybrid cables BDC-CIP | 87


BDC-CIP 1.00 mm2 H05V-U

hybrid power+fo

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-CIP 1

5. Water blocking tape 6. Central strength member (FRP) 7. 1.0 mm2 Cu – insulated copper wire 8. Ripcord

2 3 5 4 7 6

Basic Rodent Protection

Duct

FTTH

8

Hybrid FO + Power

Configuration

BDC-CIP 1.0 mm2 H05V-U Max. tensile load [N] allowed

static

1T x 12F +2x1.00 mm2

12

12

6

1

10.7

104

2700

1300

1T x 12F +4x1.00 mm2

12

12

6

1

10.7

124

2700

1300

2T x 12F +2x1.00 mm2

24

12

6

2

10.7

105

2700

1300

2T x 12F +4x1.00 mm2

24

12

6

2

10.7

125

2700

1300

3T x 12F +2x1.00 mm2

24

12

6

2

10.7

125

2700

1300

4T x 12F +2x1.00 mm2

48

12

6

4

10.7

107

2700

1300

5T x 12F +1x1.00 mm2

60

12

6

5

10.7

98

2700

1300

1T x 12F +6x1.00 mm2

12

12

8

1

12.1

162

2700

1300

1T x 12F +6x1.00 mm2

12

12

8

1

12.1

162

2700

1300

2T x 12F +6x1.00 mm2

24

12

8

2

12.1

163

2700

1300

3T x 12F +4x1.00 mm2

36

12

8

3

12.1

144

2700

1300

3T x 12F +4x1.00 mm2

36

12

8

3

12.1

144

2700

1300

4T x 12F +4x1.00 mm2

48

12

8

4

12.1

145

2700

1300

Other fiber and copper wire counts available on demand

Applications Crush

[N/10 cm]

ÆÆ

For installation into existing duct or directly buried

ÆÆ

High tensile and crush performance

Features

2700

ÆÆ

FRP strength and anti-buckling element

ÆÆ

Insulated copper cores 1.00 mm2 (Ø 2.3 mm)

ÆÆ

Loose tubes with filling compound (PBT Ø 2.2 mm)

ÆÆ

Tape and dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as strain relief elements

ÆÆ

UV stabilized HDPE outer jacket

ÆÆ

Other outer jackets materials available

Operating temperature +100 +70°C +55°C

-15°C -40°C

Technical copper wire characteristics Max DC resistance

18.1 Ω/km@20°C

Conductor material

Bare copper

Conductor cross section

1.00 mm2

Insulated conductor dia.

2.3 mm

Insulation material

PVC

88 | hybrid cables BDC-CIP

-100

TRANSPORT

Nominal weight ±10% [kg/km]

OPERATION

Ø ± 5% [mm]

INSTALLATION

Fibers

Active tubes

temperature [°C]

Version

Fibers Total per elements tube


BDC-DIP 1.5 mm2 H07V-U

hybrid power+fo

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-DIP 1

5. Water blocking tape 6. Central strength member (FRP) 7. 1.5 mm2 Cu – insulated copper wire 8. Ripcord

2 3 5 4 7 6

Basic Rodent Protection

Duct

FTTH

8

Hybrid FO + Power

Configuration

BDC-DIP 1.5 mm2 H07V-U Max. tensile load [N] allowed

static

1T x 12F +2x1.5 mm2

12

12

6

1

12.4

137

2700

1500

1T x 12F +4x1.5 mm2

12

12

6

1

12.4

166

2700

1500

2T x 12F +2x1.5 mm2

24

12

6

2

12.4

138

2700

1500

2T x 12F +4x1.5 mm2

24

12

6

2

12.4

167

2700

1500

3T x 12F +2x1.5 mm2

36

12

6

3

12.4

140

2700

1500

4T x 12F +2x1.5 mm2

48

12

6

4

12.4

141

2700

1500

5T x 12F +1x1.5 mm2

60

12

6

5

12.4

128

2700

1500

1T x 12F +6x1.5 mm2

12

12

8

1

14.2

228

3000

1800

2T x 12F +6x1.5 mm2

24

12

8

2

14.2

229

3000

1800

3T x 12F +4x1.5 mm2

36

12

8

3

14.2

202

3000

1800

4T x 12F +4x1.5 mm2

48

12

8

4

14.2

203

3000

1800

Applications [N/10 cm]

Other fiber and copper wire counts available on demand

Technical copper wire characteristics Max DC resistance

12.1 Ω/km@20°C

Conductor material

Bare copper

Conductor cross section

1.5 mm2

Insulated conductor dia.

2.8 mm

Insulation material

PVC

PE Black RAL 9005

Crush

ÆÆ

For installation into existing duct or directly buried

ÆÆ

High tensile and crush performance

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Insulated copper cores 1.50 mm2 (Ø 2.8 mm)

ÆÆ

Loose tubes with filling compound (PBT Ø 2.8 mm)

ÆÆ

Tape and dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as strain relief elements

ÆÆ

UV stabilized HDPE outer jacket

ÆÆ

Other outer jackets materials available

2700

Operating temperature +100 +70°C +55°C TRANSPORT

Nominal weight ±10% [kg/km]

OPERATION

Ø ± 5% [mm]

INSTALLATION

Fibers

Active tubes

temperature [°C]

Version

Fibers Total per elements tube

-15°C -40°C

-100

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

hybrid cables BDC-DIP | 89


BDC-DIP 2.5 mm2 H07V-U

hybrid power+fo

Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-DIP 1

5. Water blocking tape 6. Central strength member (FRP) 7. 2.5 mm2 Cu – insulated copper wire 8. Ripcord

2 3 5 4 7 6

Basic Rodent Protection

Duct

FTTH

8

Hybrid FO + Power

Configuration

BDC-DIP 2.5 mm2 H07V-U Max. tensile load [N] allowed

static

1T x 12F +2x2.5 mm2

12

12

6

1

13.7

175

2800

1700

1T x 12F +4x2.5 mm2

12

12

6

1

13.7

223

2800

1700

2T x 12F +2x2.5 mm2

24

12

6

2

13.7

177

2800

1700

2T x 12F +4x2.5 mm2

24

12

6

2

13.7

225

2800

1700

3T x 12F +2x2.5 mm2

36

12

6

3

13.7

179

2800

1700

4T x 12F +2x2.5 mm2

48

12

6

4

13.7

180

2800

1700

5T x 12F +1x2.5 mm2

60

12

6

5

13.7

158

2800

1700

1T x 12F +6x2.5 mm2

12

12

8

1

15.7

311

2800

1700

2T x 12F +6x2.5 mm2

24

12

8

2

15.7

313

2800

1700

3T x 12F +4x2.5 mm2

36

12

8

3

15.7

267

2800

1700

4T x 12F +4x2.5 mm2

48

12

8

4

15.7

268

2800

1700

Other fiber and copper wire counts available on demand

Technical copper wire characteristics Max DC resistance

7.41 Ω/km@20°C

Conductor material

Bare copper

Conductor cross section

2.5 mm2

Insulated conductor dia.

3.3 mm

Insulation material

PVC

90 | hybrid cables BDC-DIP

Applications Crush

[N/10 cm]

ÆÆ

For installation into existing duct or directly buried

ÆÆ

High tensile and crush performance

Features ÆÆ

FRP strength and anti-buckling element

ÆÆ

Insulated copper cores 2.50 mm2 (Ø 3.3 mm)

ÆÆ

Loose tubes with filling compound (PBT Ø 3.2 mm)

ÆÆ

Tape and dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as strain relief elements

ÆÆ

UV stabilized HDPE outer jacket

ÆÆ

Other outer jackets materials available

2700

Operating temperature +100 +70°C +55°C

-15°C -40°C

-100

TRANSPORT

Nominal weight ±10% [kg/km]

OPERATION

Ø ± 5% [mm]

INSTALLATION

Fibers

Active tubes

temperature [°C]

Version

Fibers Total per elements tube


hybrid power+fo BDC-DID 0.8 mm Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP

hybrid cables BDC-DID

3

5. Water blocking tape 6. Central strength member (FRP) 7. 2x Ø 0.8/1.3 insulated Cu pair 8. Ripcord

1

2 3

5

4

6 7

Basic Rodent Protection

Duct

FTTH

8

Hybrid FO + Power

Configuration

BDC-DID 0.8 mm

1T x 12F + 7x2x0,8Cu

12

12

8

1

13.1

162

2T x 12F + 6x2x0,8Cu

24

12

8

2

13.1

161

3T x 12F + 5x2x0,8Cu

36

12

8

3

13.1

160

4T x 12F + 4x2x0,8Cu

48

12

8

4

13.1

158

5T x 12F + 3x2x0,8Cu

60

12

8

5

13.1

157

6T x 12F + 2x2x0,8Cu

72

12

8

6

13.1

156

7T x 12F + 1x2x0,8Cu

84

12

8

7

13.1

154

Max. tensile load [N] allowed

static

Applications [N/10 cm]

2900

1900

Technical copper wire characteristics PN-EN 50290-1-1:2002

Maximum resistance of wire loop

75 Ω/km@20°C

Insulation resistance

1500 MΩ·km

Material of conductor

Copper

Nominal diameter of conductor

0.8 mm

Nominal diameter of insulation

1.3 mm

Insulation material

PE

PE Black RAL 9005

ÆÆ

For installation into existing duct or directly buried

ÆÆ

High tensile and crush performance

Features

Other fiber and copper wire counts available on demand

Standard

Crush

2000

ÆÆ

FRP strength and anti-buckling element

ÆÆ

Insulated copper pairs 2xØ 0.8/1.3 mm

ÆÆ

Loose tubes with filling compound (PBT Ø 2.5 mm)

ÆÆ

Tape and dry yarns to prevent moisture into the cable

ÆÆ

Fiberglass yarns as strain relief elements

ÆÆ

UV stabilized HDPE outer jacket

ÆÆ

Other outer jackets materials available

Operating temperature +100 +70°C +55°C TRANSPORT

Nominal weight ±10% [kg/km]

OPERATION

Ø ± 5% [mm]

INSTALLATION

Fibers

Active tubes

temperature [°C]

Version

Fibers Total per elements tube

-15°C -40°C

-100

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

hybrid cables BDC-DID | 91


NOTES

92 | fiber optic cables NOTES


NOTES

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

fiber optic cables NOTES | 93


NOTES

94 | fiber optic cables NOTES


NOTES

PE Black RAL 9005

LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

fiber optic cables NOTES | 95


FIBRAIN SP. Z O.O. Rogoźnica 312 36-060 Głogów Małopolski Poland phone: (+48) 17 866-08-14 fax: (+48) 17 866-08-11 e-mail: info@fibrain.com

FIBRAIN MÉXICO Paseo de la Reforma 250 / Piso 9 Esquina c/Niza, Col. Juárez Del. Cuahtémoc México D.F. 06600 phone: (+52) 55 3600 7546 e-mail: info@fibrain.com.mx

www.fibrain.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.