fiber optic cables fibrain Information
Application FOC Parameters Low Loss Fibers SM/MM Bendsafe Fibers Fiber and Cables Information Fiber Identification
Page 5
Page 5 Page 6 Page 7 Page 8 Page 9 Page 10
DATACOM
Page 16
FTTH
Page 34
Furcation tube FSMX Buffer BFR Simplex SMX Duplex ZIP LDC LBR DC-PRIM DC-DRIM EXO-CU EXO-C0 EXO-CI EXO-GU EXO-G0 EXO-GI BDC-MSA
VC-D20 VC-D30 VC-D40 VC-DCY Resibend® Cables VC-D30 Resibend® VC-D30 Resibend Plus® Easy Section Module Cables VC-D30 Easy Section Module VC-D40 Easy Section Module DC-PRIM EAC-RAs EAC-RAm DAC-BURRY VC-T60 Aero-DF03
Page 17 Page 18 Page 19 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32
Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50
content
5
16
34
fiber optic cables fibrain MICRODUCT
Page 51
Telecom Duct
Page 63
Telecom Aerial
Page 71
Special Cable Designs
Page 83
MK-AX2 MK-DX2/25/3 MK-LX4 MK-LXS6/7/8 MK-LXS9/10 MK-LX6 MK-LX7 MK-LX8 MK-LX9 MK-LX11
BDC-MSA BDC-MIB BDC-C0 BDC-CI BDC-CK DDC-SI DDC-CI
Aero-DF03 Aero-AS02 2.0 mm Aero-AS03 2.0 mm Aero-AS03 2.5 mm Aero-AS04 2.0 mm Aero-AS04 2.5 mm Aero-AS06 2.0 mm Aero-AS06 2.5 mm Aero-AS09 2.5 mm Aero-AS12 2.5 mm Aero-AS14 2.5 mm
FTTA-DAC BDC-CIP 1.5 mm2 BDC-CIP 0.5 mm2 H05V-U BDC-CIP 0.75 mm2 H05V-U BDC-CIP 1.00 mm2 H05V-U BDC-DIP 1.50 mm2 H07V-U BDC-DIP 2.50 mm2 H05V-U BDC-DID 0.80 mm
Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62
Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70
Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82
Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91
content
51
63
71
83
Information
Mechanical features
symbols Basic Rodent Protection
High Rodent Protection
Rodent Protection Extreme
Flexible
Last mile connection outdoor
Aerial
Hi-crush
Direct buried
Duct
Microduct Generation 1
ETR
Industrial
Mining
Military
Oil resistance
Ship and oshore
Robotic
Windfarms
Datacenter
Datacom
Telecom
FTTH
FTTA
Semi-tight
Easy-strip
LSOH
Compact design
Flexible
MultiďŹ ber connectors termination
Easy to terminate
Last mile connection indoor
Bendsafe
Low Friction
Blowing installation
Design features
Branch of business
Optimal Diameter
Hybrid FO + Power
symbols | 5
FOC
FOC Parameters
parameters single-mode fiber types
Fiber types and applications
Maximum attenuation for uncabled fibers IL [dB/km]
Fiber type ITU-IT
Possibility to remove the 900 μm coat at the distance of 3-5 cm
1383 nm
1410 nm
1450 nm
1490 nm
≤0.34
≤0.31
-
-
≤0.24
≤0.20
≤0.23
Premium single mode fiber low loss G.652D LL with zero water-peak and lower attenuation in whole bandwidth
≤0.32
≤0.31
-
-
≤0.21
≤0.18
≤0.20
Long distance single mode fiber with non-zero dispersion shifted G.655 – (NZDSF) for CWDM and DWDM A,B,C,D system 10G and future 40G or 100G
-
≤0.40
≤0.32
≤0.26
-
≤0.19
≤0.21
Long distance single mode fiber G.656 – with non-zero dispersion shifted A,B,C,D (NZDSF) for CWDM and DWDM system 10G and future 40G or 100G
-
≤0.40
≤0.32
≤0.26
-
≤0.19
≤0.21
Available bend radius
Bend insensitive fiber fully G.657A1 compatible with G.652D standard, bend radius 10-15 mm
≤0.35
≤0.35
-
-
≤0.24
≤0.20
≤0.23
BEND RADIUS
Bend insensitive fiber fully G.657A2 compatible with G.652D standard, bend radius 7.5 mm
≤0.35
≤0.35
-
-
≤0.24
≤0.20
≤0.23
Bend insensitive fiber fully G.657B3 (A3) compatible with G.652D standard, bend radius 5 mm
≤0.35
≤0.35
-
-
≤0.24
≤0.20
≤0.23
Bend insensitive fiber, non-compatible with G.652D standard, for G.657B3 Plus connectorization application, bend radius 2.5 mm
≤0.35
Standard single mode telecommuG.652D nication fiber with zero water-peak attenuation
-
≤0.35
-
1550 nm 1625 nm
Tight 900 μm fiber
1310 nm
≤0.24
≤0.21
≤0.23
Semi-tight 900 μm fiber
Possibility to remove the 900 μm coat at the distance of 10-20 cm
Easy strip 900 μm fiber
Possibility to remove the 900 μm coat at the distance of 100-150 cm
7.5
BEND RADIUS
10
mm
mm
BEND RADIUS
BEND RADIUS
15
mm
30
mm
multimode fiber types BEND RADIUS
Overfilled modal bandwidth [MHz/km]
Fiber type ITU-T
Fiber Capacity [m]
Attenuation [dB/km]
Bending loss 2 turns [dB]
Bending loss 10 turns [dB]
Radius = 7.5 mm Radius = 15 mm
Radius = 30 mm
850 nm
40GBASE1300 SR4/ 1GBase-SR 10GBase-SR nm 100GBASESR10
850 nm
1300 nm
62.5/125 OM1
≥ 160
≥ 500
275
-
-
2.6
0.5
50/125 OM2 Bend Insensitive
≥ 500
≥ 500
600
83
-
2.3
0.5
≥ 0.2
≥ 0.5
≥ 0.1
≥ 0.3
-
50/125 OM3 Bend Insensitive
≥ 1500
≥ 500
1000
300
140*
2.4
0.5
≥ 0.2
≥ 0.5
≥ 0.1
≥ 0.3
-
50/125 OM4 Bend Insensitive
≥ 3500
≥ 500
1100
550
170*
2.4
0.6
≥ 0.2
≥ 0.5
≥ 0.1
≥ 0.3
-
850 nm
1300 nm
850 nm
1300 nm
-
850 nm 1300 nm ≥ 0.5
* Maximum cabled fiber attenuation 3.0 dB/km at 850 nm, maximum total connector loss of 1.0 dB and VCSELs maximum RMS spectral width of 0.29 nm (according to IEEE 10GbE model: http://grouper.ieee.org/groups/802/3/ae/public/adhoc/serial_pmd/documents/10GEPBud3_1_16a.xls).
Bending loss G.652D
Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.03 dB
Mandrel R=25 mm 1310/1550 nm 100 turns 0.03 dB
Mandrel R=15 mm 10 turn 1550 nm ≤0.25 dB 1625 nm ≤1.0 dB
G.652D LL
Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.03 dB
Mandrel R=25 mm 1310/1550 nm 100 turns 0.03 dB
Mandrel R=15 mm 10 turn 1550 ≤0.25 dB 1625 nm≤1.0 dB
G.655 – A.B.C.D
Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.05dB
Mandrel R=15 mm 1550/1625 nm 1 turn ≤0.5 dB
G.656 – A.B.C.D
Mandrel R=30 mm 100 turns 1550/1625 nm ≤0.05 dB
Mandrel R=15 mm 1550/1625 nm 1 turn ≤0.5 dB
G.657A1
Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn 1550 nm 1550nm≥0.20 dB. 1625 nm ≤0.50 dB ≥0.50 dB. 1625 nm ≤1.50 dB
G.657A2
Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn 1550 nm≥0.03 dB. 1625nm ≤0.10 dB 1550 nm≥0.10 dB. 1625 nm ≤0.2dB;
Mandrel R=7.5 mm 1 turn 1550 nm ≥0.50 dB. 1625 nm ≤1.0 dB
G.657B3 (A3)
Mandrel R=10 mm 1 turn Mandrel R=7.5 mm 1 turn 1550 nm 1550 nm≥0.03 dB. 1625 nm ≤0.10 dB ≥0.05 dB. 1625 nm ≤0.15 dB
Mandrel R=5 mm 1 turn 1550 nm≥0.10 dB. 1625 nm ≤0.30 dB
G.657B3 Plus
Mandrel R=5 mm 1 turn Mandrel R=2.5 mm 1 turn 1550 nm 1550 nm≥0.10 dB. 1625nm ≤0.20 dB ≥0.20 dB. 1625 nm ≤0.30dB
40
mm
BEND RADIUS
60
mm
low loss
Low Loss Fibers
fibers
At present, low loss and pure quartz optic fibers with max. 0.17 dB/km attenuation at 1550 nm wavelength and max. 0.31 dB/km at 1310 nm wavelength are ready for use. Low loss and pure quartz optic fibers have at least 0.02 dB/km lower spectral attenuation in comparison to the standard ones G.652D. In such fibers, the retention of flat spectral characteristics within the transmission windows provide the possibility of achieving substantially smaller deviations of attenuation: ÆÆ 1310 nm (+ 20 nm / -35 nm) wavelength – max. deviation is 0.03 dB/km ÆÆ 1550 nm ( + 25 nm / -25 nm) wavelength – max. deviation is 0.02 dB/km with the retention of 1625 nm attenuation 0.20 dB/km.
The chromatic dispersion complies with ITU-T G.652 and the polarizing at the level of ≤ 0.04 ps/√km of these fibers provides the possibility of using such fibers in high- speed systems e.g. transmission of 10 GBit/s or even higher. Low loss fibers which are obtained in the pure quartz technology can work properly in telecommunication networks at the distance of even thousand kilometers far, which significantly limits the number of necessary amplifiers and repeaters in a fiber optic connection.
0.40 0.30
G.657.A1
G.652.D LL
G.652.D
G.657.A1
G.652.D LL
G.652.D
G.657.A1
G.652.D LL
G.652.D
G.657.A1
G.652.D LL
G.652.D
0
G.657.A1
0.10
G.652.D LL
0.20 G.652.D
Attenuation [dB/km]
Attenuation / Wavelength
25 16
50 15
90 14
83 13
10 13
Wavelength [nm]
low loss Fibers Introduction | 7
low loss
Low Loss Fibers
fibers
Performance Specifications Parameter
Value
Attenuation [dB/km] 1310 nm 1383 ± 3 nm 1490 nm 1550 nm 1625 nm
≤ 0.32 ≤ 0.32 ≤ 0.21 ≤ 0.18 ≤ 0.20
Attenuation Difference [dB/km] The attenuation from λ1 [nm] to λ2 [nm] shall not exceed the attenuation at λ3 [nm] by more than Δ
λ1 1285 1525
λ2 1330 1575
λ3 1310 1550
Δ 0.03 0.02
nm 1550 1310 1550 1625
dB ≤0.03 ≤0.03 ≤0.03 ≤0.03
Point Discontinuity [dB] 1310 nm and 1550 nm
≤ 0.05
Optical Return Loss [dB] Absolute value at all points along the fiber
Attenuation with Bending [dB]
Cable Cutoff Wavelength [nm]
≥ 60 Turns 1 100 100 100
mm 32 50 50 60 ≤ 1260
Mode Field Diameter [µm] 1310 nm
9.2±0.4
1550 nm
10.4±0.5
Dispersion [ps/(nm•km)] 1550 nm 1625 nm Zero Dispersion Wavelength - λo [nm] Zero Dispersion Slope - So [ps/(nm2•km)]
≤ 18.0 ≤ 22.0 1304 to 1324 ≤ 0.092
Polarization Mode Dispersion (ps/√km) Individual fiber
≤ 0.1
Link value
≤ 0.04
Environmental / Attenuation Effects (dB/km) Temperature Dependence (–60°C to +85°C) Temperature-Humidity Cycling (-10°C to +85°C with humidity cycling up to 98% RH)
1310 / 1550 / 1625 nm ≤ 0.05 ≤ 0.05
Dry Heat Soak (85±2°C)
≤ 0.05
Water Immersion (23±2°C)
≤ 0.05
Damp Heat Soak (85±2°C, 85% RH, 30 Days)
≤ 0.05
Fiber Curl
≤ 0.05
Deflection for 10 mm overhang (µm)
≤12.4
Corresponding radius of curvature (meters)
≥ 4.0
Minimum Strength (by Proof Test) Operating Temperature Range
8 | foc low loss fibers
0.69 GPa (100 kpsi) -60°C to +85°C
SM/MM
SM/MM Fibers
BENDSAFE FIBERS
Available bend radius BEND RADIUS
BEND RADIUS
BEND RADIUS
10
7.5
BEND RADIUS
15
BEND RADIUS
30
mm
mm
mm
mm
G.657B2,B3
G.657B3
G.652A1,A2
G.652D
BEND RADIUS
40
60
mm
mm
Bendsafe SM Fibers
10 7,5
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
0.10dB 0.03dB
G.657B3 (A3)
1.00dB 0.50dB
0.20dB 0.10dB
G.657A2 0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
G.657A1
Max. attenuation for wavelength 1550 nm 1625 nm/both [dB]
15
0.50dB
0.05dB
0.05dB
G.656 - A.B.C.D
0.50dB
G.655 - A.B.C.D
1.00dB 0.25dB
0.03dB
0.03dB
30
0.03dB
0.03dB
Bend radius [mm]
40
G.652D LL
1.00dB 0.25dB
G.652D
60
Bendsafe MM Fibers
10
0.20dB 0.50dB
0.10dB 0.30dB
0.20dB 0.50dB
50/125 OM4 Bend Insensitive
Bending loss for wavelength 850nm 1300nm/both [dB]
15
0.10dB 0.30dB
30
0.20dB 0.50dB
Bend radius [mm]
40
50/125 OM2 50/125 OM3 Bend Insensitive Bend Insensitive
0.10dB 0.30dB
60
7,5
FOC sm/mm bendsafe fibers | 9
FOC
Post-production fiber parameters Type
Fiber and cables Information
fiber and cables information
Tight buffer vs. Loose tube Attenuation [dB/km]
1310
1550
850
1300
Low Loss (LL)
0.34
0.22
-
-
Telecom
0.35
0.25
-
-
Standard
0.40
0.30
-
-
Datacom
0.40
0.30
3.50
1.50
2-3mm 900µm
900 µm outer coating
Tube
Gel
Core
125 µm coating
Stripping Tight buffer Tight 900 μm fiber
Semi-tight Semi-tight 900 μm fiber
Easy strip Easy strip 900 μm fiber
Possibility to remove the 900 μm coat at the distance of 3-5 cm
Possibility to remove the 900 μm coat at the distance of 10-20 cm
Possibility to remove the 900 μm coat at the distance of 100-150 cm.
10 | foc fiber and cables information
Loose tube
Tight buffer
250 µm coating
FOC
telecom
fiber identification
Fiber color codes in Loose tube cable design Other colors available on demand T-Telecom (according to IEC 60304) 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Code
12
1
2 3
11
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
10
4 9
Color
5 8
Code red
green
blue
white
violet
orange
grey
yellow
brown
pink
natural
7
6
aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
T1-TELecom (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02) 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Code
12
Color
red
blue
white
green
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
2 3
10
4 9
5 8
Code Color
1
11
red
blue
white
green
violet
orange
grey
yellow
brown
pink
natural
7
6
aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
T2-TELecom (according to EIA 598A) 1-12
1
2
3
4
5
6
7
8
9
10
11
12 12
Code
2 3
11
Color
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
10
4 9
5 8
Code Color
1
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
7
6
aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
FOC fiber color codes | 11
FOC
telecom
fiber in Loose tube color codes
Loose tube color codes in Loose tube cable design Other colors available on demand t-telecom - Loose tube in cable (according to iec60304): Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code Color
1
2
11
3
9
5
10
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
4
8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
7
6
t1-telecom - Loose tube in cable (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02) Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code Color
1
2
11
3
9
5
10
red
blue
white
green
violet
orange
grey
yellow
brown
pink
black
aqua
4
8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
7
6
t2-telecom - Loose tube in cable (according to EIA 598A) Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code Color
1
2
11
3
9
5
10
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
4
8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
7
6
t3-telecom - Loose tube in cable according to IEC 60304) Tube
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Code Color
3
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
luminous red
patina green
1
2
3
4
5
6
7
8
9
10
11
12
signal blue
red
green
white
white
white
white
white
white
white
white
white
white
Code
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
12 | foc fiber color codes
1
4
12
5 6
11 10
E-telecom - Loose tube in cable (according to EIA 598A)
Color
2
13
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
Tube
1
15 14
2
9
8
7
FOC
datacom
fiber color codes
Fiber, buffer and tubes color codes for Datacom cables range Other colors available on demand D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) Fiber in buffer 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
natural orange
pink
Color*
red
green
blue
yellow
white
grey
brown
violet
brown
dark green
orange
pink
5
6
7
8
9
10
11
12
Fiber Buffer 250/900/600 µm
Fiber Buffer 250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
Fibers in tubes 1-12
1
2
3
4
24
Code
13 1
23
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark green
orange
15
22
16
21
17 20
Code Color
14 2
19
18
pink
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Loose tubes in cables Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code Color
1
2 3
11
red
green
blue
white
violet
orange
grey
yellow
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
brown
pink
black
aqua
10
4 9
5 8
7
6
FOC fiber color codes | 13
FOC
datacom
fiber color codes
Fiber and buffer color codes for datacom cables range Other colors available on demand D1-DATACOM (according to IEC 60304 ; TIA/EIA 598-A ; TIA/EIA 598-C /Data Center cables) Fiber in buffer 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Color
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
aqua
Color*
blue
orange
green
brown
grey
white
red
dark green
yellow
violet
pink
aqua
5
6
7
8
9
10
11
12
Fiber Buffer 250/900/600 µm
Fiber Code 250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
Fibers in tubes 1-12
1
2
3
4
24
Code
13 1
23
Color
blue
orange
green
brown
grey
white
red
yellow
yellow
violet
pink
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
aqua
14 2
15
22
16
21
17 20
19
18
Code Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Loose tubes in cables Tube
1
2
3
4
5
6
7
8
9
10
11
12 12
Code Color
1
2 3
11
red
green
blue
white
violet
orange
grey
yellow
**In cable with a multi-layer construction color of the tubes will be repeated in second layer ***In case of lower fiber count some tubes can be replaced by fillers
14 | foc fiber color codes
brown
pink
black
aqua
10
4 9
5 8
7
6
FOC
ftth
fiber color codes
Fiber and buffer color codes for FTTH cables range Other colors available on demand F-FTTH (according to DIN VDE 0888 & IEC 60304) 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color*
red
blue
green
yellow
violet
white
orange
grey
brown
dark green
aqua
pink
Fiber Buffer 250 µm
600/900 µm
Fiber Code 250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
FOC fiber color codes | 15
FIBRAIN COATINGS
Industrial
Oil resistance
Mining
Ship and oshore
Military
Windfarms
Robotic
Datacenter
Telecom
Physical properties of coatings PE polyethylene
LSOH
PVC polyvinyl chloride
PUR polyurethane
PA polyamide
NBR nitrile rubber
Mechanical resistance
Mechanical resistance
Mechanical resistance
Mechanical resistance
Mechanical resistance
Mechanical resistance
Temperature resistance
Temperature resistance
Temperature resistance
Temperature resistance
Temperature resistance
Temperature resistance
Chemical resistance
Chemical resistance
Chemical resistance
Chemical resistance
Chemical resistance
Chemical resistance
datacom
Furcation tube FSMX 1.6 - 2.8 mm
furcation tube fsmx Cable structure
1
1. LSOH outer jacket 2. Aramid yarns 3. Central Tube 900 μm
2 3
TRUE COLORS
Flexible
Easy to terminate
Bendsafe
Configuration
FSMX Ø nominal ± 5% [mm]
Version
Nominal weight ± 5% [kg/km]
Max. installation tension (ε=0.5 %) [N]
Crush [N/10 cm]
FSMX 1.8
1.8/0.9/0.5
4
100
200
FSMX 2.8
2.8/0.9/0.5
8
350
300
Applications ÆÆ
Distribution systems cable
ÆÆ
For patchcords and pigtails
ÆÆ
Terminals connection
Jacket colors
Standard
Features
Yellow RAL 1021 White RAL 9010
Blue RAL 5015
Orange RAL 2003
Aqua RAL 6027
Violet RAL 4003
ÆÆ
LSOH with low coefficient of friction
ÆÆ
Aramid yarns
ÆÆ
Central tube 900 µm
Low-radius bending resistance SM
Color codes 30 mm
4
5
6
7
8
9
10
11
12
Fiber Buffer Color 900 µm
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
15 mm
G.657A1
7.5 mm
G.657A2
pink
Operating temperature +100 +70°C +55°C
-5°C -10°C
TRANSPORT
3
OPERATION
2
G.652D
INSTALLATION
1
temperature [°C]
1-12
bend radius [mm]
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
-40°C
-100
datacom furcation tube fsmx | 17
datacom
Buffer BFR 0.6 - 0.9 mm
Buffer bFR Cable structure
1
1. Outer Tight Buffer Tube 600/900 µm (LSOH) 2. Colored coating on fiber 250 µm 3. Optical Fiber with cladding 125 µm
3
2
TRUE COLORS
Flexible
Easy to terminate
Semi-tight
Easy-strip
Bendsafe
Configuration
BFR Version
Fiber qty
Ø nominal ± 5% [mm]
Max. installation tension ± 5% [N]
1F
1
0.6
4
1F
1
0.9
5
Applications
Crush [N/10cm] 200
ÆÆ
Distribution systems cable
ÆÆ
For patchcords and pigtails
ÆÆ
Terminals connections
Available outer jacket colors
SM G.652D Yellow RAL 1021
Features
SM G.657 MM 62.5/125 OM1 A1 / A2 / A3 Blue RAL 5015 White RAL 9010
MM 50/125 OM2 Orange RAL 2003
MM 50/125 OM3 Aqua RAL 6027
MM 50/125 OM4 Violet RAL 4003
Stripping
250 µm fiber
ÆÆ
Variants with different stripability
1
TB00 / TB05 / TB10
+100 +70°C +55°C
3-5 / 10-20 / 100-150
Color codes D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers 1
2
3
4
5
6
7
8
9
10
11
-5°C -10°C
12 -40°C
Fiber
-100
Buffer red
green
blue
yellow
white
18 | datacom buffer bfr cables
grey
brown
violet
aqua
black
orange
pink
TRANSPORT
1F
Stripping - length in one piece [cm]
OPERATION
1
Stripping
INSTALLATION
1F
Color
ÆÆ
temperature [°C]
Fiber qty
250/600/900 µm
Buffer made of LSOH with low coefficient of friction
Operating temperature
Version
1-12
ÆÆ
datacom
Simplex SMX 1.2 - 2.8 mm
simplex smx cable Cable structure
1
1. LSOH outer jacket 2. Aramid yarns 3. Central tight buffer Tube 600/900 μm
2 3
TRUE COLORS
Flexible
Easy to terminate
Semi-tight
Easy-strip
Bendsafe
Configuration
smx Version
Ø nominal ± 5% [mm]
Fiber qty
Max. installation tension (ε=0.5 %) [N]
Crush [N/10 cm]
1F
1
1.2
50
200
1F
1
1.6
100
300
1F
1
1.8
150
400
1F
1
2.0
200
500
1F
1
2.8
300
800
Applications ÆÆ
Distribution systems cable
ÆÆ
For patchcords and pigtails
ÆÆ
Terminals connection
Features
Jacket colors
Standard
ÆÆ
LSOH with low coefficient of friction
ÆÆ
Aramid yarns
ÆÆ
Central tight buffer tube 600/900 µm
ÆÆ
250 µm colored fiber
Low-radius bending resistance SM Blue RAL 5015
Orange RAL 2003
Aqua RAL 6027
Violet RAL 4003
Color codes D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers 1-12
1
2
3
4
5
6
7
8
9
30 mm bend radius [mm]
Yellow RAL 1021 White RAL 9010
10
11
G.652D
15 mm
G.657A1
7.5 mm
G.657A2
12
Fiber
Operating temperature blue
yellow
white
grey
brown
violet
aqua
black
orange
+100
pink
+70°C +55°C
-5°C -10°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color
250/600/900 µm
INSTALLATION
Buffer
-40°C
-100
datacom simplex smx cables | 19
DATACOM CABLES
TRUE COLORS
Selection of tubes and cables colors Other colors available on demand
orange
green
grey
red
violet
yellow
black
brown
pink
aqua
datacom
Duplex Zip Cables 1.6 - 2.8 mm
duplex zip cables
1
Cable structure 1. LSOH outer jacket 2. Aramid yarns 3. Central tight buffer Tube 600/900 µm with colored fibers 250 µm
2
3
TRUE COLORS
LSOH
Bendsafe
Easy to terminate
Easy-strip
Semi-tight
Configuration
ZIP Fiber qty
Dimensions nominal ± 5% [mm]
Max. installation tension (ε=0.5 %) [N]
Crush [N/10 cm]
2F
2
1.6 x 3.3
200
500
2F
2
1.8 x 3.7
300
500
2F
2
2.0 x 4.1
400
500
2F
2
2.8 x 5.7
600
1000
Applications ÆÆ
Distribution systems cable
ÆÆ
Patchcords and pigtails
ÆÆ
Terminals connection
Structure and composition
Jacket colors
Standard
MM 50/125 OM2 Orange RAL 2003
250 µm colored fibers
SM low-radius bending resistance 30 mm
15 mm
G.657A1
7.5 mm
G.657A2
Operating temperature +100 +70°C +55°C
-5°C -10°C
TRANSPORT
MM 50/125 OM4 Violet RAL 4003
G.652D
OPERATION
MM 50/125 OM3 Aqua RAL 6027
MM 62,5/125 OM1 Blue RAL 5015
Aramid yarns
ÆÆ
bend radius [mm]
SM G.657 A1 / A2 / A3 White RAL 9010
LSOH with low coefficient of friction
ÆÆ
temperature [°C]
SM G.652D Yellow RAL 1021
ÆÆ
INSTALLATION
Version
-40°C
-100
datacom DUPLEX ZIP CABLES | 21
datacom
LDC
LDC Cable structure
1
3
2
1. Outer jacket LSOH UV Stabilized 2. Tight Tubes 900 µm (LSOH) with colored fibers 250 µm 3. Aramid yarns
TRUE COLORS
LSOH
Bendsafe
Easy to terminate
Semi-tight
Easy-strip
Datacenter
Configuration
LDC Version
Tight buffers [pcs]
Ø ± 5% [mm]
Nominal weight LSOH ± 5% [kg/km]
2F
2
4.5
21
4F
4
5.0
26
6F
6
5.5
30
8F
8
5.5
35
10F
10
6.5
40
12F
12
6.5
45
16F
16
7.0
50
24F
24
8.0
65
Max. tensile load [N] installation
operation
500
Crush [N/10 cm]
125 500
700
175
1000
250
Applications ÆÆ
Indoor/outdoor installations
ÆÆ
Distribution networks in multifamily buildings
ÆÆ
FTTD Connections
ÆÆ
Distribution systems
ÆÆ
Fully dielectric
ÆÆ
LAN and FTTX network
ÆÆ
ODF connection
ÆÆ
Datacenter distribution
Features Jacket colors
ÆÆ
Compact design
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
ÆÆ
Lightweight
ÆÆ
Flexible
ÆÆ
Easy to strip
ÆÆ
Fully dielectric
ÆÆ
Reduced diameter
ÆÆ
Direct connectorization
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Fiber Buffer Color
250/600/900 µm
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Operating temperature +100
Fiber
+70°C
Code yellow
white
grey
brown
violet
aqua
natural orange
pink
Color*
red
green
blue
yellow
white
grey
brown
violet
brown
dark green
pink
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
orange
-5°C -10°C
-40°C
-100
22 | datacom LDC
TRANSPORT
blue
OPERATION
green
INSTALLATION
red
250 µm
temperature [°C]
+55°C
Color
datacom
LBR
LBR Cable structure 1. Outer jacket LSOH UV Stabilized 2. Subcables 1.8 mm with tight tubes 900 µm (LSOH) with 250 µm colored fibers
1 2
3
3. Aramid yarns 4. Central FRP strength member 5. Ripcord
1 2
3
4
TRUE COLORS
LSOH
Bendsafe
Easy to terminate
Semi-tight
Easy-strip
5
Datacenter
Configuration
LBR Version
Fiber qty
Ø ± 5% [mm]
Nominal weight LSOH ± 5% [kg/km]
installation
operation
4F
4
6.5
48
750
250
6F
6
7.5
63
1200
400
8F
8
8.7
85
1500
12F
12
10.9
131
Max. tensile load [N]
1500
Crush [N/10 cm]
Applications ÆÆ
Indoor/outdoor installations
ÆÆ
Distribution networks in multifamily buildings
ÆÆ
FTTD Connections
ÆÆ
Distribution systems
500
ÆÆ
Fully dielectric
500
ÆÆ
LAN and FTTX network
ÆÆ
ODF connection
ÆÆ
Datacenter distribution
16F
16
11.3
119
1700
550
18F
18
11.3
131
1700
550
24F
24
13.0
179
2000
660
2000
Features
Standard jacket colors:
PE Black RAL9005
LSOH Grey RAL7022
ÆÆ
Simplex sub cable up to 24 fibers
ÆÆ
Fully dielectric cable
ÆÆ
Aramid yarns as tensile elements
ÆÆ
UV Resistant and LSOH flame retardant outer jacket
LSOH Light Grey RAL7037
Operating temperature +100
Outer jacket color options:
+70°C
SM G.652D RAL 1021
SM G657A1, A2, A3 RAL 9010
MM 50/125 OM2 RAL 2003
MM 50/125 OM3 RAL6027
MM 50/125 OM4 RAL4003
TRANSPORT
OPERATION
-5°C
INSTALLATION
temperature [°C]
+55°C
-20°C -40°C
-100
datacom LBR | 23
datacom
DC-PRIM
DC-PRIM Cable structure
1
1. LSOH outer jacket 2. Aramid yarns 3. 250 µm optical fibers
2 3
TRUE COLORS
LSOH
Bendsafe
Easy to terminate
Datacenter
Configuration
DC-PRIM No. of fibers
12
24
Outer diameter [mm] (±5%)
3.0
3.5
Max tensile load (ε=0.5%) [N]
350
350
8
9
Weight [kg/km] (±10%) Crush [N/10 cm]
Applications
350
Min. bend radius [mm]
45 (depends on fiber type)
60 (depends on fiber type)
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection, fully dielectric cable
ÆÆ
MTP/MPO termination cable
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
Inside house OLT connection
ÆÆ
Data Center connections cable
Outer jacket color options:
Features Ivory RAL 1015
Yellow RAL 1021
White RAL 9010
Blue RAL 5015
Orange RAL 2003
Green RAL 6018
Aqua RAL 6027
Violet RAL 4003
ÆÆ
Aramid strength element
ÆÆ
250 µm optical fibers (12-24)
ÆÆ
LSOH outer jacket
Available colors Operating temperature
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1
2
3
4
5
6
7
8
9
10
11
+100
12
+70°C
Fiber blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Fiber Code Color*
red
green
blue
*Fiber with black mark to identify fibers 13-24
24 | datacom DC-PRIM
yellow
white
grey
brown
violet
brown
dark green
orange
pink
-5°C -10°C
-40°C
-100
TRANSPORT
green
OPERATION
red
temperature [°C]
+55°C
Color
INSTALLATION
1-12
datacom
DC-DRIM
DC-DRIM
1
1
Cable structure
2
2
1. LSOH outer jacket 2. Aramid yarns 3. LSOH inner jacket 4. Aramid yarns 5. 250 µm optical fibers
3
3 5
4
TRUE COLORS
LSOH
Bendsafe
Easy to terminate
Datacenter
Configuration
DC-DRIM No. of fibers
12
24
Outer diameter [mm] (±5%)
4.5
5.0
Max tensile load (ε=0.5%) [N]
600
600
8
9
Weight [kg/km] (±10%) Crush [N/10cm]
Applications
300
Min. bend radius [mm]
65 (depends on fiber type)
75 (depends on fiber type)
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection, fully dielectric cable
ÆÆ
MTP/MPO termination cable
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
Inside house OLT connection
ÆÆ
Data Center connections cable
Outer jacket color options:
Features Ivory RAL 1015
Yellow RAL 1021
White RAL 9010
Blue RAL 5015
Orange RAL 2003
Green RAL 6018
Aqua RAL 6027
Violet RAL 4003
ÆÆ
Aramid strength element in two layers
ÆÆ
250 µm optical fibers (12-24)
ÆÆ
LSOH double jacket
Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1
2
3
4
5
6
7
Operating temperature 8
9
10
11
12
+100 +70°C
Fiber blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Fiber Code Color*
red
green
blue
*Fiber with black mark to identify fibers 13-24
yellow
white
grey
brown
violet
brown
dark green
orange
+55°C
-5°C -10°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color
INSTALLATION
1-12
pink -40°C
-100
datacom DC-DRIM | 25
datacom
EXO-CU Cables Loose tube
exo-cU cables
1
Cable structure
Datacom
ETR
Compact design
1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord
Basic Rodent Protection
LSOH
LSOH Jacket
Exo-CU Version
Fiber qty
Ø ± 5% [mm]
Max. tensile load [N] installation
1T x 2F
2
6.4
47
1T x 4F
4
6.8
48
1T x 6F
6
6.8
51
(ε=0,33%)
1T x 8F
8
6.8
51
1600
1T x 12F
12
6.8
52
1T x 24F
24
7.1
62
4
5
Configuration Nominal weight LSOH ± 5% [kg/km]
3
2
Crush [N/10 cm]
operation
1100
300
700
Applications ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
(ε=0,5%)
Features
Available colors
ÆÆ
Fiberglass strength element
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound
ÆÆ
Loose tube (PBT)
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
LSOH outer jacket
1
2
3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
aqua
dark green
Code green
blue
yellow
white
grey
brown
violet
orange
pink
+100 +70°C
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Fiber identification
Jacket colors
Standard 24
13 1
23
14 2
16
21
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3 RAL 9010
MM 50/1025 OM2 RAL 2003
26 | datacom exo-CU cables
MM 50/1025 OM3 RAL6027
MM 50/1025 OM4 RAL4003
-40°C
17 20
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-5°C -10°C
15
22
PE Black RAL 9005
temperature [°C]
+55°C
19
18
-100
TRANSPORT
red
OPERATION
Color
Operating temperature
INSTALLATION
1-12
datacom
EXO-C0 Cables Loose tube
exo-c0 cables
1
Cable structure
Datacom
ETR
Compact design
1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord
Basic Rodent Protection
LSOH
LSOH Jacket
Exo-C0 Fiber qty
1T x 2F
2
6.8
52
1T x 4F
4
7.2
53
1Tx 6F
6
7.2
57
1T x 8F
8
7.2
58
1T x 12F
12
7.2
58
1T x 16F
16
7.4
62
1T x 24F
24
7.4
62
Max. tensile load [N] installation
Crush [N/10 cm]
operation
1300
(ε=0,33%)
500
1900
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1500
(ε=0,5%)
Features
Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Code
ÆÆ
Fiberglass strength element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound
ÆÆ
Loose tube (PBT)
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
LSOH outer jacket
Operating temperature +100
Code green
blue
yellow
white
grey
brown
violet
dark green
aqua
orange
pink
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Fiber identification
Jacket colors
+55°C
-5°C -10°C
TRANSPORT
red
temperature [°C]
Color
+70°C
OPERATION
1-12
Applications
INSTALLATION
Version
Ø ± 5% [mm]
4
5
Configuration Nominal weight LSOH ± 5% [kg/km]
3
2
Standard 24
13 1
23
-40°C
14 2
15
22
16
21
17 20
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-100
19
18
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3 RAL 9010
MM 50/1025 OM2 RAL 2003
MM 50/1025 OM3 RAL6027
MM 50/1025 OM4 RAL4003
datacom exo-c0 Cables | 27
1
Cable structure
Compact design
Basic Rodent Protection
LSOH
5
LSOH Jacket
Configuration
Exo-CI Version
Fiber qty
Nominal weight LSOH ± 5% [kg/km]
Ø ± 5% [mm]
1T x 2F
2
7.1
52
1T x 4F
4
7.4
53
1Tx 6F
6
7.4
57
1T x 8F
8
7.4
58
1T x 12F
12
7.4
58
1T x 16F
16
7.7
62
1T x 24F
24
7.7
62
Max. tensile load [N] installation
Crush [N/10 cm]
operation
1800
(ε=0,33%)
1000
2700
2
3
4
5
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1500
Features
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1
Applications
(ε=0,5%)
Available colors 1-12
6
7
8
9
10
11
12
Code Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
aqua
dark green
ÆÆ
Fiberglass strength element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound
ÆÆ
Loose tube (PBT)
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
LSOH outer jacket
Operating temperature
Code red
green
blue
yellow
white
grey
brown
violet
+100 orange
+55°C
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Fiber identification
Jacket colors
Standard 24
13 1
23
15
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
PE Black RAL 9005
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3 RAL 9010
17 19
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
MM 50/1025 OM2 RAL 2003
28 | datacom exo-CI CABLES
MM 50/1025 OM3 RAL6027
MM 50/1025 OM4 RAL4003
-40°C 16
21
PE Black RAL 9005
-5°C -10°C
14 2
22
20
+70°C
pink temperature [°C]
Color
4
18
-100
TRANSPORT
ETR
3
2
INSTALLATION
Datacom
1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord
OPERATION
datacom
EXO-CI Cables Loose tube
exo-cI cables
datacom
EXO-GU Cables Loose tube
exo-GU cables
1
Cable structure
Datacom
ETR
Compact design
1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord
Basic Rodent Protection
LSOH
LSOH Jacket
Exo-GU Version
Fibers per tube
Fiber qty
Ø ± 5% [mm]
1T x 2F
2
2
5.8
34
1T x 4F
4
4
5.8
34
1T x 6F
6
6
5.8
35
1T x 8F
8
8
5.8
35
1T x 12F
12
12
5.8
35
1T x 16F
16
16
5.8
35
1T x 18F
18
18
5.8
36
1T x 24F
24
24
5.8
36
Max. tensile load [N] installation
4
5
Configuration Nominal weight LSOH ± 5% [kg/km]
3
2
Crush [N/10 cm]
operation
1200
(ε=0,33%)
400
1500
Applications ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1500
(ε=0,5%)
Features
Available colors
ÆÆ
Central Loose tube (PBT) with filling compound
ÆÆ
Optical fibers
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
LSOH outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark green
orange
pink
Code
Code Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
Fiber identification
Jacket colors
Standard 24 23
+55°C
-5°C -20°C
15
16
21
17 20
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
+70°C
14 2
22
PE Black RAL 9005
+100
-100
13 1
Operating temperature
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
19
18
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3 RAL 9010
MM 50/1025 OM2 RAL 2003
MM 50/1025 OM3 RAL 6027
MM 50/1025 OM4 RAL 4003
datacom exo-GU Cables | 29
datacom
EXO-G0 Cables Loose tube
exo-G0 cables
1
Cable structure
Datacom
ETR
Compact design
1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord
Basic Rodent Protection
LSOH
LSOH Jacket
Exo-G0 Version
1T x 2F
Fiber qty 2
2
Ø ± 5% [mm] 5.9
Applications
Max. tensile load [N]
Nominal weight LSOH ± 5% [kg/km]
Crush [N/10 cm]
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
37
ÆÆ
Distribution network
ÆÆ
ODF connections
1T x 4F
4
4
5.9
37
1T x 6F
6
6
5.9
37
1T x 8F
8
8
5.9
37
1T x 12F
12
12
5.9
38
1T x 16F
16
16
5.9
38
1T x 18F
18
18
5.9
38
1T x 24F
24
24
5.9
40
installation
4
5
Configuration
Fibers per tube
3
2
operation
1500
(ε=0,33%)
500
2200
1500
Features
(ε=0,5%)
Available colors
ÆÆ
Central Loose tube (PBT) with filling compound
ÆÆ
Optical fibers
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
LSOH outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark green
orange
pink
Code
Code Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
Fiber identification
Jacket colors
Standard 24 23
14 2
15
22
16
21
17 20
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3 RAL 9010
MM 50/1025 OM2 RAL 2003
30 | datacom exo-g0 CABLES
MM 50/1025 OM3 RAL 6027
MM 50/1025 OM4 RAL 4003
19
+100 +70°C +55°C
-5°C -20°C
-100
13 1
Operating temperature
18
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
datacom
EXO-GI Cables Loose tube
exo-GI cables
1
Cable structure
Datacom
ETR
Compact design
1. LSOH outer jacket 2. Central Loose tube (PBT) with colored fibers in filling compound 3. Optical fibers 4. Fiberglass yarns 5. Ripcord
Basic Rodent Protection
LSOH
3
2
5
LSOH Jacket
Configuration
Exo-GI Version
Fiber qty
Ø ± 5% [mm]
Fibers per tube
Applications
Max. tensile load [N]
Nominal weight LSOH ± 5% [kg/km]
installation
4
Crush [N/10 cm]
operation
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1T x 2F
2
2
6.1
38
1T x 4F
4
4
6.1
38
1T x 6F
6
6
6.1
39
1T x 8F
8
8
6.1
40
1T x 12F
12
12
6.1
40
1T x 16F
16
16
6.1
41
1T x 18F
18
18
6.1
42
ÆÆ
Central Loose tube (PBT) with filling compound
42
ÆÆ
Optical fibers
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
LSOH outer jacket
1T x 24F
24
24
6.1
1800
(ε=0,33%)
600
2700
1500
(ε=0,5%)
Features
Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark green
orange
pink
Code
Code Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
Fiber identification
Jacket colors
Standard 24 23
+70°C +55°C
-5°C -20°C
14 2
15
22
16
21
17 20
PE Black RAL 9005
+100
-100
13 1
Operating temperature
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
19
18
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3 RAL 9010
MM 50/1025 OM2 RAL 2003
MM 50/1025 OM3 RAL 6027
MM 50/1025 OM4 RAL 4003
datacom exo-GI Cables | 31
datacom
DATACOM BDC-MSA
bdc-MSA
1
Cable structure 6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord
1. LSOH outer jacket 2. Water-blocking fiberglass yarns 3. Water blocking yarns 4. PET tape 5. Central strength member (FRP)
Datacom
ETR
Compact design
2 4
5
3 6
7 8
Basic Rodent Protection Datacenter
LSOH
Configuration
BDC-msa Fibers per tube
Total elements
Ø ± 5% [mm]
Active tubes
installation
Crush
[N/10 cm]
operation
1T x 12F
12
12
6
1
8.2
50
65
1500
550
2T x 6F
12
6
6
2
8.2
50
65
1550
780
2T x 12F
24
12
6
2
8.2
51
65
1500
550
4T x 6F
24
6
6
4
8.2
51
66
1550
780
3T x 12F
36
12
6
3
8.2
52
67
1500
550
6T x 6F
36
6
6
6
8.2
53
68
1550
780
4T x 12F
48
12
6
4
8.2
53
68
1500
550
5T x 12F
60
12
6
5
8.2
54
69
1500
550
6T x 12F
72
12
6
6
8.2
54
69
1500
550
8T x 12F
96
12
8
8
9.3
71
86
1620
750
12T x 12F
144
12
12
12
11.5
104
126
1620
850
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
Features 1500
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 1.8 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass as water absorbent and strain relief element
ÆÆ
UV stabilized LSOH jacket
Operating temperature
Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 2
3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Tubes Tube
1
2
3
4
5
6
7
8
9
10
11
12
Code Color
+70°C +55°C
-5°C -20°C -40°C
red
green
blue
yellow
white
*In case of lower fiber count some tubes can be replaced by fillers.
32 | datacom bdc-MSA cables
grey
brown
violet
aqua
black
orange
pink
-100
TRANSPORT
1
temperature [°C]
1-12
+100
OPERATION
Fibers
INSTALLATION
Version
Applications
Max. tensile load [N]
Nominal weight LSOH ±5% [kg/km]
Nominal weight PE ±5% [kg/km]
FTTH Cables
VC-D20/VC-D30 VC-D40/VC-DCY SOLID CONNECTION TO YOUR PROVIDER
BEND
RESISTANCE
EASY TO
TERMINATE
LSOH
SAFE COVER
SMALL DIMENSIONS
SAFE
DAILY USE
ftth
FTTH VC-D20
VC-d20
1
Cable structure
2 3
1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber
Last mile connection outdoor
LSOH
Flexible
Easy to terminate
Bendsafe
FTTH
Configuration
VC-d20 No. of fibers
Applications
1F 900 µm ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
10-60 mm*
ÆÆ
LAN and FTTX networks
300
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Outer diam [mm]
2.0
Tensile load perm/inst. [N]
75/200
Weight [kg/km]
7
Min. bend radius [mm] Crush [N/10 cm] *Depends on fiber type
Bend radius/maximum attenuation Features ÆÆ
Aramid strength element
ÆÆ
Optical 900 µm semi tight tube
ÆÆ
LSOH outer jacket
Operating temperature +100 +70°C
-5°C
TRANSPORT
+55°C OPERATION
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3) 0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
0.03dB
G.657A2
INSTALLATION
7,5
G.657A1
temperature [°C]
10
G.652D LL
Max. attenuation for wavelength 1550 nm 1625nm/both [dB]
15
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
-20°C -40°C
-100
ftth VC-D20 cables
| 35
ftth
FTTH VC-D30
VC-d30
1
2 3
Cable structure 1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber
Last mile connection outdoor
LSOH
Flexible
Easy to terminate
Bendsafe
FTTH
Configuration
VC-d30 No. of fibers
Applications
1F 900 µm
Outer diam [mm]
3.0
Tensile load perm/inst. [N]
60/170
Weight [kg/km]
8
Min. bend radius [mm]
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
10-60 mm*
ÆÆ
LAN and FTTX networks
500
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Crush [N/10 cm] *Depends on fiber type
Bend radius/maximum attenuation
10 7,5
Features
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3) 0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
G.657A2
Max. attenuation for wavelength 1550 nm 1625nm/both [dB]
15
G.657A1 0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
G.652D LL
0.03dB
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
ÆÆ
Aramid strength element
ÆÆ
Optical 900 µm semi tight tube
ÆÆ
LSOH outer jacket
Operating temperature +100
-20°C -40°C
-100
36 | ftth VC-D30 cables
TRANSPORT
-5°C
OPERATION
+55°C INSTALLATION
temperature [°C]
+70°C
ftth
FTTH VC-D40
VC-d40
1
Cable structure 1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber
Last mile connection outdoor
LSOH
Flexible
Easy to terminate
2
3
Bendsafe
FTTH
Configuration
VC-d40 No. of fibers
Applications
1-2F 900 µm ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
10-60 mm*
ÆÆ
LAN and FTTX networks
1000
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Outer diam [mm]
4.0
Tensile load perm/inst. [N]
150/400
Weight [kg/km]
15
Min. bend radius [mm] Crush [N/10 cm] *Depends on fiber type
Bend radius/maximum attenuation Features ÆÆ
Aramid strength element
ÆÆ
Optical 900 µm semi tight tube
ÆÆ
LSOH outer jacket
Operating temperature +100 +70°C
-5°C
TRANSPORT
+55°C OPERATION
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3) 0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
0.03dB
G.657A2
INSTALLATION
7,5
G.657A1
temperature [°C]
10
G.652D LL
Max. attenuation for wavelength 1550 nm 1625nm/both [dB]
15
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
-20°C -40°C
-100
ftth VC-D40 cables
| 37
ftth
FTTH VC-DCY
VC-dcy
3
2
Cable structure 1. LSOH outer jacket (white/ivory/black) 2. FRP rod 3. 250 µm optical fibers
Last mile connection outdoor
LSOH
Flexible
Easy to terminate
Bendsafe
FTTH
Hi-crush
Configuration
VC-dCY No. of fibers
Applications
1-4F 900 µm
Outer diam [mm]
ÆÆ
FTTH drop cable reinforced with FRP rods
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
15-40 mm*
ÆÆ
LAN and FTTX networks
1000
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
2.0x3.1 ±0.1
Tensile load perm/inst. [N]
50/100
Weight [kg/km]
8.3
Min. bend radius [mm] Crush [N/10 cm] *Depends on fiber type
Bend radius/maximum attenuation
10 7,5
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3) 0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
G.657A2
Max. attenuation for wavelength 1550 nm 1625nm/both [dB]
15
G.657A1 0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
G.652D LL
0.03dB
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
Features ÆÆ
FRP rods
ÆÆ
250 µm optical fibers
ÆÆ
LSOH outer jacket
Operating temperature +100
-30°C
-100
38 | ftth VC-Dcy cables
TRANSPORT
OPERATION
INSTALLATION
temperature [°C]
+70°C +55°C
1
ftth
FTTH VC-D30 RESIBEND®
VC-d30 resibend®
1 3
Cable structure
2
1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber
Resibend®
Last mile connection outdoor
LSOH
Flexible
Easy to terminate
FTTH
Bendsafe
Configuration
VC-d30 resibend® No. of fibers
Applications
1F 900 µm
Outer diam [mm]
3.0
Tensile load perm/inst. [N]
60/170
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
Weight [kg/km]
8
Min. bend radius [mm]
ÆÆ
Last mile connection
10
ÆÆ
LAN and FTTX networks
Crush [N/10 cm]
500
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Bend radius/maximum attenuation
G.657B3 (A3) Fiber bending radius [mm] 5
Max. change in attenuation [dB]
Features
1550 nm
1625 nm
0.10
0.25
ÆÆ
Aramid yarns as strain relief
ÆÆ
Optical fiber in 900 µm semi tight buffer
ÆÆ
LSOH outer jacket (various colors available)
ÆÆ
G.657B3 A3 optical fibers
7.5
0.05
0.15
10
0.03
0.10
Operating temperature +100
-20°C -40°C
-100
40 | ftth VC-D30 resibend® cables
TRANSPORT
-5°C
OPERATION
+55°C INSTALLATION
temperature [°C]
+70°C
ftth
FTTH VC-D30 RESIBEND PLUS®
VC-d30 resibend plus®
1 3
Cable structure
2
1. LSOH outer jacket 2. Aramid yarns 3. 900 µm central semi tight buffer tube with 250 µm colored fiber
Resibend Plus®
Last mile connection outdoor
LSOH
Flexible
Easy to terminate
FTTH
Bendsafe
Configuration
VC-d30 resibend plus® No. of fibers
Applications
1F 900 µm
Outer diam [mm]
3.0
Tensile load perm/inst. [N]
60/170
Weight [kg/km]
8
Min. bend radius [mm]
7.5
Crush [N/10 cm]
500
Bend radius/maximum attenuation
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
G.657B3 Plus Fiber bending radius [mm]
Max. change in attenuation [dB]
Features
1550 nm
1625 nm
2.5
0.20
0.30
ÆÆ
Aramid yarns as strain relief
5
0.10
0.20
ÆÆ
Optical fiber in 900 µm semi tight buffer
ÆÆ
LSOH outer jacket (various colors available)
ÆÆ
G.657B3 optical fibers
Operating temperature +100
TRANSPORT
-5°C
OPERATION
+55°C INSTALLATION
temperature [°C]
+70°C
-20°C -40°C
-100
ftth VC-D30 resibend plus® cables
| 41
ftth
FTTH VC-D30 Easy Section Module
VC-d30 Easy Section Module
1 3
Cable structure
2
1. LSOH outer jacket 2. Aramid yarns 3. Optical fibers (250 µm) in Easy Section Module
Last mile connection outdoor Last mile connection outdoor
Easy Section Module
Bendsafe LSOH
Easy to terminate
Flexible
Bendsafe
FTTH
Configuration
VC-D30 Easy Section Module Active modules
2F
2
2
1
1
3.1
9
4F
4
4
1
1
3.1
9
allowed
170
static
60
Applications Crush [N/10 cm]
1000
Bend radius/maximum attenuation
7,5
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3) 0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
G.657A2 0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
0.03dB
G.657A1
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Features ÆÆ
Aramid strength element
ÆÆ
Optical fibers (up to 4 pcs) inside 900µm FlexModule
ÆÆ
LSOH outer jacket
Operating temperature +100 +70°C temperature [°C]
10
G.652D LL
Max. attenuation for wavelength 1550 nm 1625nm/both [dB]
15
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
ÆÆ
+55°C
-5°C
TRANSPORT
Total elements
Max. tension [N]
OPERATION
Fibers
Nominal weight ±5% [kg/km]
Ø ± 5% [mm]
INSTALLATION
Version
Fibers per module
-20°C -40°C
-100
ftth Vc-d30 Easy Section Module
| 43
ftth
FTTH VC-D40 Easy Section Module
VC-d40 Easy Section Module
1 3
Cable structure
2
1. LSOH outer jacket 2. Aramid yarns 3. Optical fibers (250 µm) in Easy Section Module
Easy Section Module
Last mile connection outdoor
LSOH
Easy to terminate
Flexible
Bendsafe
FTTH
Configuration
VC-D40 Easy Section Module Version
Fibers
Fibers per module
Total elements
Active modules
Nominal weight ±5% [kg/km]
Ø ± 5% [mm]
2F
2
2
1
1
4.1
15
4F
4
4
1
1
4.1
15
Max. tension [N] allowed
420
static
150
Applications Crush [N/10 cm]
1000
Bend radius/maximum attenuation
10 7,5
0.30dB 0.20dB
G.657B3 Plus 0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
0.10dB 0.03dB
1.00dB 0.50dB
G.657B3 (A3)
Max. attenuation for wavelength 1550 nm 1625nm/both [dB]
15
0.20dB 0.10dB
G.657A2 0.10dB 0.03dB
1.50dB 0.50dB
G.657A1 0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
G.652D LL
0.03dB
30
0.03dB
Bend radius [mm]
40
0.03dB
60
1.00dB 0.25dB
G.652D
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Features ÆÆ
Aramid strength element
ÆÆ
Optical fibers (up to 4 pcs) inside 900µm FlexModule
ÆÆ
LSOH outer jacket
Operating temperature +100
-20°C -40°C
-100
44 | ftth VC-D40 Easy Section Module
TRANSPORT
-5°C
OPERATION
+55°C INSTALLATION
temperature [°C]
+70°C
ftth
DC-PRIM
DC-PRIM
1
Cable structure
2
1. LSOH outer jacket 2. Aramid yarns 3. 250 µm optical fibers
3
TRUE COLORS
LSOH
Bendsafe
Datacenter
Easy to terminate
Configuration
DC-PRIM
Applications
No. of fibers
12
24
Outer diameter [mm]
3.0
3.5
350/150
350/150
8
9
45 (depends on fiber type)
50 (depends on fiber type)
Tensile load perm/inst. [N] Weight [kg/km] Min. bend radius [mm] Min. bend radius [mm]
150
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection, fully dielectric cable
ÆÆ
MTP/MPO termination cable
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
Inside house OLT connection
ÆÆ
Data Center connections cable
Available colors D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Features
Fiber
ÆÆ
Aramid strength element
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
ÆÆ
250 µm optical fibers (12-24)
13-24
13
14
15
16
17
18
19
20
21
22
23
24
ÆÆ
LSOH outer jacket
Fiber
Operating temperature blue
*Fiber with black mark to identify fibers 13-24
yellow
white
grey
brown
violet
brown
dark green
orange
+100
pink
+70°C +55°C
-5°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color*
INSTALLATION
Code
-20°C -40°C
-100
ftth DC-PRIM
| 45
ftth
FTTH EAC-RAs
EAC-Ras Cable structure 1. LSOH outer jacket 2. Dielectric strength members 3. 900 µm semi tight buffer (LSOH) with colored 250 µm optical fiber
1 2
3
Last mile connection outdoor
LSOH
FlexibleEasy to Easy to terminate terminate
Bendsafe
FTTH
Configuration
EAC-Ras
Version
Fibers
Nominal weight ±5% [kg/km]
Ø ± 5% [mm]
Buffers
Max. tensile load [N]
Applications Crush [N/10 cm]
installation
8F
8
8
8.7
68
400
12F
12
12
8.7
72
400
16F
16
16
12.0
98
600
24F
24
24
12.0
106
600
2
3
4
5
6
7
For laying in risers
ÆÆ
FTTH feeder
ÆÆ
Easy access and installation
Features
F-FTTH (according to DIN VDE 0888 & IEC 60304) 1
Distribution cable
ÆÆ
1000
Available colors 1-12
ÆÆ
8
9
10
11
ÆÆ
FRP strength members inside cable jacket
ÆÆ
Optical fibers in bundles
ÆÆ
2-24 elements in cable
ÆÆ
LSOH UV resistant outer jacket (ivory by default, various colors available)
12
Fiber
Operating temperature green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
600/900 µm
Fiber Code Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color*
red
blue
green
yellow
violet
white
orange
grey
brown
dark green
aqua
pink
250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
+100 +70°C +55°C
-5°C
TRANSPORT
blue
OPERATION
red
250 µm
INSTALLATION
Color
temperature [°C]
Buffer
-20°C -40°C
-100
Fiber extraction up to 25 m
Fiber extraction
46 | ftth EAC-RAs cables
ftth
FTTH EAC-RAm
EAC-RAm Cable structure 1. LSOH outer jacket 2. Dielectric strength members 3. FlexModules with 250 µm colored fiber
1 2
3
Easy Section Module
Last mile connection outdoor
LSOH
Easy to terminate
Flexible
Bendsafe
FTTH
Configuration Last mile
connection outdoor
Version
EAC-RAm
Fibers
Ø ± 5% [mm]
FlexModules
Nominal weight ±10% [kg/km]
Max. tensile load [N] ε=0.6% Δ α≤ 0.1 dB, reversible
Crush [N/10 cm]
2F FlexModules 12-18
6-9
8,7
69
400
20-30
10-15
9,5
79
400
32-48
16-24
12,0
106
600
16-36
4-9
8,7
70
400
40-48
10-12
9,5
78
400
52-60
13-15
10,5
85
400
64-96
16-24
12,0
110
600
500
Applications ÆÆ
Distribution cable
ÆÆ
For laying in risers
ÆÆ
FTTH feeder
ÆÆ
Easy access and installation
4F FlexModules
Features
500
6F FlexModules 70
400
30-72
5-12
78-96
13-16
10,5
90
400
12,0
112
600
102-144
17-24
13,0
130
600
16-32
2-4
8,7
67
400
40-96
5-12
10,5
89
400
24-48
2-4
8,7
70
400
60-120
5-8
10,5
90
400
48
9-12
12,0
115
600
2-24 elements in cable
ÆÆ
LSOH UV resistant outer jacket (ivory by default, various color available)
500
Operating temperature +100
8F FlexModules
+70°C
temperature [°C]
500
12F FlexModules 500
+55°C
-5°C
TRANSPORT
8,7
Optical fibers in bundles
ÆÆ
OPERATION
2-4
FRP strength members inside cable jacket
ÆÆ
INSTALLATION
12-24
ÆÆ
-20°C -40°C
F-FTTH (according to DIN VDE 0888 & IEC 60304) 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color 250 µm
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
blue
green
yellow
violet
white
orange
grey
brown
dark green
aqua
pink
-100
Fiber
Fiber extraction up to 25 m
Module Fiber extraction
Module Color*
*Black mark to identify FlexModules 13-24
ftth EAC
| 47
ftth
FTTH DAC-BURRY
DAC-Burry
1
Cable structure
2
1. PP/HDPE outer jacket 2. Aramid yarns 3. Central Loose tube (PBT) with 250 µm colored fibers in filling gel 4. Dielectric strength members in the jacket
Direct buried
Last mile connection outdoor
FTTH
Hi-crush
4
3
Compact design
Configuration
DAC-BURRY Version
Fibers
Fibers per tube
Ø ± 5% [mm]
Nominal weight PE ± 5% [kg/km]
1T x 2F
2
2
6.2
32
1T x 4F
4
4
6.2
32
1Tx 6F
6
6
6.2
32
1T x 8F
8
8
6.2
32
1T x 12F
12
12
6.2
32
Max. tensile load [N] installation
operation
650
Applications Crush [N/10 cm]
250
3500
ÆÆ
Optical access cable with aramid yarns reinforcement
ÆÆ
Direct buried design
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
High crush resistance (3,5kN)
ÆÆ
Installation into existing ducts or direct buried
Features
Available colors T-Telecom (according to IEC 60304) - Fibers in tube 1-12
1
2
3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
ÆÆ
Central Loose tube (PBT) with filling compound
ÆÆ
Up to 12 optical fibers (250 µm)
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
Embedded FRP strength members
ÆÆ
Highly resistant outer jacket made of hard polyolefin material, UV resistant
Operating temperature +100
-40°C
-100
48 | ftth DAC-BURRY cables
TRANSPORT
OPERATION
-15°C
INSTALLATION
temperature [°C]
+70°C +55°C
ftth
VC-T60
vc-t60 Cable structure 1. HDPE UV resistant outer jacket 2. Aramid yarns 3. Inner LSOH jacket 4. FRP rods 5. Module with optical fibers
1
3
2
5 4
TRUE COLORS
LSOH
Bendsafe
Easy-strip
Easy to terminate
Semi-tight
Datacenter
Configuration
VC-t60
1-4
allowed
static
1
5.6
30
1200
400
Applications Crush [N/10 cm] 2000
ÆÆ
Drop cable for FTTH networks
ÆÆ
Optical access cable with aramid yarns reinforcement
ÆÆ
Direct buried construction
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
Features ÆÆ
Aramid yarns as strength and water absorbent elements
ÆÆ
Easy strip buffer or modules with optical fibers
ÆÆ
Embedded strength members (FRP)
ÆÆ
Highly resistant outer jacket made of HDPE material
ÆÆ
UV stabilized
Operating temperature +100 +70°C span: 100 m
sag: 2.2 m
+55°C
-5°C
TRANSPORT
NESC Light
OPERATION
1-4
Total elements
Nominal weight ±5% [kg/km]
INSTALLATION
1-4F
Fibers
Max. tensile load [N]
Ø ± 5% [mm]
temperature [°C]
Version
Fibers per module
-20°C -40°C
NSC Medium span: 55 m
-100 sag: 1.1 m
NESC Heavy span: 30 m
sag: 0.6 m
ftth VC-t60
| 49
ftth
FTTH aero-df03
aero-df03 Cable structure 4. Central Loose tube (PBT) with 250 µm colored fibers in filling gel 5. FRP strength member
1. PE jacket 2. Ripcord 3. Water blocking yarns
Last mile connection outdoor
Aerial
4
3
5
Telecom
Hi-crush
FTTH
1 2
Cable variants Version
AERO-DF03
AERO-DF03
Fiber count
1-12
16-24
Cable dimensions [mm]
8.3 x 4.6 (±3%)
8.7 x 5.0 (-3%)
Cable weight [kg/km]
37
38
Max. installation tension[N]
1300
1300
Applications
Mechanical and enviromental characteristics
ÆÆ
Installation on poles or walls
ÆÆ
Can be installed in pipelines
ÆÆ
Fully dielectric cable
Parameter Crush performance
5000 N
Bending performance
10 cycles [20 x D]
Water Penetration
3 m sample, 1 m head, 24 h
Features ÆÆ
Loose tube with filling compound (PBT)
ÆÆ
Up to 24 fibers in a cable
Available colors
ÆÆ
Two FRP strength elements
T-Telecom (according to IEC 60304) - Fibers in tube
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Ripcord yarns For easy jacket removal
ÆÆ
PE UV resistant Jacket
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Code
Operating temperature +100
Code white
violet
orange
grey
yellow
brown
pink
natural
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm NESC Light
aqua
-15°C
span: 120 m
-40°C
sag: 2.4 m
NSC Medium span: 70 m
sag: 1.4 m
NESC Heavy span: 40 m
sag: 0.8 m
50 | ftth AERO-DF03
-100
TRANSPORT
blue
OPERATION
green
INSTALLATION
red
temperature [°C]
Color
+70°C +55°C
Microduct
TRENCH
MICROCABLES
OPTIMAL DIAMETER HIGH BLOWING RANGE HIGH FIBERS DENSITY
LOW FRICTION COEFFICIENT
UNIT DESIGN
microduct
MICRODUCT MK-AX2
MK-AX2
1
Cable structure 1. Polymeric jacket with low coefficient of friction 2. 250 µm colored fibers
Microduct Generation 1
Last mile connection outdoor
FTTH
Blowing installation
Flexible
Compact design
2
Bendsafe
Configuration
MetroJET MK-AX2 Fibers
1T x 2F
2
1.1
1.2
1T x 4F
4
1.1
Max. install. tension [N]
Crush [N/10 cm]
ÆÆ
Microduct air-blowing application
ÆÆ
Metro networks
1.4
ÆÆ
Flexible network design
ÆÆ
Distribution network
1.6
1T x 8F
8
1.5
1.8
1T x 10F
10
1.6
2.0
1T x 12F
12
1.6
2.2
15
100
Features
Compatibility table
standard microduct Version
[mm]
Inner Ø [mm]
Direct burried ducts
MK-AX2 2-4F
6-12F
Outer Ø [mm]
Inner Ø [mm]
7/3.5
7
3.5
Version
2-4F
5/3.5
5
3.5
7/3.8
7
3.8
7/5.5
7
5.5
7/4
7
4
10/8
10
8
10/5.5
10
5.5
12/10
12
10
12/8
12
8
-
12
14/10
14
10
-
Fiber qty
Available colors
2-12
Fiber qty
ÆÆ
250 µm colored fibers
Operating temperature
2.1
14
Central tube without gel
6-12F
3
14/12
Polymeric jacket with low coefficient of friction
ÆÆ
MK-AX2
3/2.1
-
ÆÆ
+100 +70°C +55°C
2-12
-15°C
OPERATION
1.5
INSTALLATION
6
Outer Ø
Applications
temperature [°C]
1T x 6F
Nominal weight ±10% [kg/km]
TRANSPORT
Version
Ø ± 5% [mm]
-30°C -40°C
-100
microduct MK-Ax2 | 53
microduct
MICRODUCT MK-DX2/25
MK-DX2/25
1
Cable structure
2
1. HDPE with low coefficient of friction 2. Aramid yarns 3. Central Loose tube (PBT) with 250 µm colored fibers in filling gel
Blowing installation
Flexible
Compact design
Bendsafe
MetroJET MK-DX2/25 Nominal weight ±10% [kg/km]
Ø ± 5% [mm]
Fibers
1T x 2F
2
2.0
3,9
1T x 4F
4
2.0
3.9
1T x 6F
6
2.3
4.4
1T x 8F
8
2.3
4.5
1T x 10F
10
2.3
4.6
1T x 12F
12
2.3
4.6
Applications
Max. installation tension [N]
Crush [N/10 cm]
300
500
direct burried ducts
Inner Ø
MK-DX2
MK-DX25
3/2.1
3
2.1
-
-
5/3.5
5
3.5
-
7/5.5
7
5.5
10/8
10
8
12/10
12
10
-
14/12
14
12
[mm]
[mm]
Fiber qty
FTTH & Distribution networks
ÆÆ
Flexible network design
ÆÆ
Last mile connection
ÆÆ
Blowing & pulling installation method
Outer Ø
Inner Ø
7/3.5
7
3.5
7/3.8
7
3.8
7/4
7
4
10/5.5
10
5.5
-
12/8
12
8
-
-
14/10
14
10
2-4
4-12
Version
[mm]
[mm]
Fiber qty
MKDX2
MKDX25 -
ÆÆ
HDPE with low coefficient of friction
ÆÆ
Aramid yarns
ÆÆ
Central tube with gel
ÆÆ
250 µm colored fibers
ÆÆ
Microbending resistant fiber G657A1 as standard
Operating temperature +100 +70°C +55°C
-
-
2-4
4-12
temperature [°C]
standard microduct Outer Ø
Microduct cabling system
ÆÆ
Features
Compatibility table
Version
ÆÆ
INSTALLATION
Version
-15°C -30°C
Available colors
-40°C
T-Telecom (according to IEC 60304) - Fibers in tube 1-12
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
54 | Microduct MK-DX2/25
-100
TRANSPORT
Last mile connection outdoor
FTTH
OPERATION
Microduct Generation 1
3
microduct
MICRODUCT MK-LX4
MK-LX4
Cable structure (MK-LX4) 5. Water blocking yarns 1. HDPE outer jacket 6. Water blocking yarns 2. Loose tubes (PBT) on strand element with colored fibers in 7. Ripcord filling gel 3. Fillers 4. Central strength member (FRP)
1
2
3
4
5 6
7 Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LX4 Version
Fibers per tube
Fibers
Total elements
Active tubes
Fillers
Max. tensile load [N]
Nominal weight ±10% [kg/km]
Ø ± 5% [mm]
1T x 4F
4
4
6
1
5
4.2
8
2T x 4F
6
4
6
2
4
4.2
8
3T x 4F
12
4
6
3
3
4.2
9
4T x 4F
16
4
6
4
2
4.2
9
5T x 4F
20
4
6
5
1
4.2
10
6T x 4F
24
4
6
6
0
4.2
10
installation
operation
250
150
Applications Crush
[N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
500
Features ÆÆ
HDPE, UV stabilized outer jacket with low friction
Other fiber counts available on demand
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
Compatibility table
ÆÆ
PBT tubes containing up to 4 optical fibers
ÆÆ
Smallest outer diameter for blowing into 5.5 mm (ID) ducts
Direct burried ducts
3
2.1
-
5/3.5
5
3.5
-
7/5.5
7
5.5
10/8
10
8
12/10
12
10
14/12
14
12
MK-LX4
-
Fiber qty
4-24
Outer Ø [mm]
Inner Ø
7/3.5
7
3.5
-
7/3.8
7
3.8
-
7/4
7
4
-
10/5.5
10
5.5
12/8
12
8
14/10
14
10
Version
MK-LX4
[mm]
Operating temperature +100 +70°C +55°C
Fiber qty
4-24
Available colors
-30°C
T-Telecom (according to IEC 60304) - Fibers 1-12
1
2
3
4
Code Color
-40°C
T-Telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
red
green
blue
white
violet
orange
Code red
-15°C
TRANSPORT
3/2.1
[mm]
OPERATION
Inner Ø
[mm]
INSTALLATION
Outer Ø
Version
temperature [°C]
standard microduct
green
blue
white
Color
-100
*In case of lower fiber count some tubes can be replaced by fillers.
microduct MK-LX4 | 55
microduct
MICRODUCT MK-LXS6/7/8
MK-LXs6/7/8 Cable structure (MK-LXS6) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord
1
2
3
4
5 6
7 Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LXS6 Active tubes
Fillers
6T x 4F
24
4
6
6
0
5.3
18
6T x 6F
36
6
6
6
0
5.3
18
6T x 8F
48
8
6
6
0
5.3
19
6T x 10F
60
10
6
6
0
5.3
19
4T x 12F
48
10
6
4
2
5.3
20
6T x 12F
72
12
6
6
0
5.3
21
Max. tensile load [N] installation
650
operation
200
Applications Crush
[N/10 cm]
Nominal weight ±10% [kg/km]
Fibers
8T x 4F
32
4
8
8
0
6.2
28
8T x 6F
48
6
8
8
0
6.2
28
8T x 8F
64
8
8
8
0
6.2
29
8T x 10F
80
10
8
8
0
6.2
30
8T x 12F
96
12
8
8
0
6.2
31
Active tubes
Fillers
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Version
Fibers
12T x 4F
48
4
12
12
0
7.8
47
12T x 6F
72
6
12
12
0
7.8
48
12T x 8F
96
8
12
12
0
7.8
49
12T x 10F
120
10
12
12
0
7.8
50
12T x 12F
144
12
12
12
0
7.8
52
Total elements
Active tubes
Other fiber counts available on demand
56 | Microduct MK-LXs6/7/8
Flexible network design
ÆÆ
Distribution network
Features
Max. tensile load [N] installation
operation
Crush
ÆÆ
HDPE, UV stabilized outer jacket with low coefficient of friction
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
ÆÆ
PBT tubes containing up to 12 optical fibers
[N/10 cm]
Operating temperature 1200
350
Max. tensile load [N] installation
operation
+100 +100
500
MetroJET MK-LXS8 Fibers per tube
Metro networks
ÆÆ
temperature temperature [°C][°C]
Fillers
Ø ± 5% [mm]
Version
Total elements
Microduct cabling air-blowing system
ÆÆ
500
MetroJET MK-LXS7 Fibers per tube
ÆÆ
Crush [N/10 cm]
+70°C +70°C +55°C +55°C
-15°C -30°C -30°C -40°C
-100 -100
1500
550
500
TRANSPORT TRANSPORT
Total elements
Nominal weight ±10% [kg/km]
OPERATION OPERATION
Fibers
Ø ± 5% [mm]
INSTALLATION INSTALLATION
Version
Fibers per tube
microduct
MICRODUCT MK-LXS9/10
MK-LXs9/10 Cable structure (MK-LX9) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking tape on strand element 7. Ripcord
3
1
2
4
5 6
7
Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LXS9 Fillers
14T x 12F
168
12
18
14
4
8.7
53
16T x 12F
192
12
18
16
2
8.7
54
18T x 12F
216
12
18
18
0
8.7
55
installation
650
operation
200
Applications Crush
[N/10 cm]
24T x 12F
Fibers
288
Fibers per tube
Total elements
12
24
Active tubes
Other fiber counts available on demand
24
Fillers
0
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
500
Features
MetroJET MK-LXS10 Version
ÆÆ
Max. tensile load [N]
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
installation
operation
[N/10 cm]
9.4
72
1000
250
500
Crush
ÆÆ
HDPE, UV stabilized outer jacket with low coefficient of friction
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
ÆÆ
PBT tubes containing up to 12 optical fibers
Operating temperature +100 +100
+70°C +70°C +55°C +55°C
-15°C
TRANSPORT TRANSPORT
Active tubes
Max. tensile load [N]
OPERATION OPERATION
Total elements
Nominal weight ±10% [kg/km]
INSTALLATION INSTALLATION
Fibers
Ø ± 5% [mm]
temperature temperature [°C][°C]
Version
Fibers per tube
-30°C -30°C -40°C
-100 -100
microduct MK-LXS9/10 | 57
microduct
MICRODUCT MK-LX6
MK-LX6 Cable structure (MK-LX6) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord
1
2
3
4
5 6
7 Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LX6 Fibers
Total elements
Active tubes
Fillers
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
1T x 4F
4
4
6
1
5
5.6
28
1T x 6F
6
6
6
1
5
5.6
28
1T x 8F
8
8
6
1
5
5.6
28
2T x 6F
12
6
6
2
4
5.6
29
4T x 6F
24
6
6
4
2
5.6
29
6T x 6F
36
6
6
6
0
5.6
29
1T x 12F
12
12
6
1
5
5.6
30
2T x 12F
24
12
6
2
4
5.6
30
3T x 12F
36
12
6
3
3
5.6
30
4T x 12F
48
12
6
4
2
5.6
31
5T x 12F
60
12
6
5
1
5.6
32
6T x 12F
72
12
6
6
0
5.6
33
Max. tensile load [N] installation
operation
Applications Crush [N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
Features 750
250
1000
ÆÆ
HDPE, UV stabilized outer jacket with low friction
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
ÆÆ
PBT tubes containing 4-12 optical fibers
ÆÆ
Smallest diameter for blowing into 8 mm (ID) ducts
Operating temperature +100
Other fiber counts available on demand
1
2
3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
-15°C -30°C -40°C
T-Telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
red
green
blue
white
violet
orange
Code Color
*In case of lower fiber count some tubes can be replaced by fillers.
58 | Microduct MK-LX6
-100
TRANSPORT
1-12
OPERATION
T-Telecom (according to IEC 60304) - Fibers
temperature [°C]
+70°C +55°C
Available colors
INSTALLATION
Version
Fibers per tube
microduct
MICRODUCT MK-LX7
MK-LX7 Cable structure (MK-LX7) 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers 4 in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord
1
3
2
5 6
7 Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LX7 Version
Fibers per tube
Fibers
Total elements
Active Fillers tubes
Ø ± 5% [mm]
Max. tensile load [N]
Nominal weight ±10% [kg/km]
8T x 4F
32
4
8
8
0
6.7
36
8T x 6F
48
6
8
8
0
6.7
37
8T x 8F
64
8
8
8
0
6.7
38
8T x 12F
96
12
8
8
0
6.7
39
installation
1600
operation
600
Applications Crush
[N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
1000
Features
Other fiber counts available on demand Available colors T-Telecom (according to IEC 60304) - Fibers 1-12
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
Code Color
ÆÆ
HDPE, UV stabilized outer jacket with low friction
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
ÆÆ
PBT tubes containing 4-12 optical fibers
ÆÆ
Smallest diameter for blowing into 8* and 10 mm (ID) ducts
* - blowing range may be lower
T-Telecom (according to IEC 60304) - Tubes 1
2
3
4
5
6
Operating temperature +100
green
blue
white
violet
orange
*In case of lower fiber count some tubes can be replaced by fillers.
grey
yellow
-15°C
TRANSPORT
red
temperature [°C]
Color
OPERATION
+70°C +55°C
Code
INSTALLATION
Tube
-30°C -40°C
-100
Microduct MK-LX7 | 59
microduct
MICRODUCT MK-LX8
MK-LX8 Cable structure 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord
1
2
3 4 5
6 Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1 7
Configuration
MetroJET MK-LX8 Version
Fibers per tube
Fibers
Total elements
Active tubes
Fillers
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
Applications Crush [N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
1T x 12F
12
12
12
1
11
8.6
53
2T x 12F
24
12
12
2
10
8.6
54
3T x 12F
36
12
12
3
9
8.6
55
4T x 12F
48
12
12
4
8
8.6
56
5T x 12F
60
12
12
5
7
8.6
57
6T x 12F
72
12
12
6
6
8.6
57
ÆÆ
HDPE, UV stabilized outer jacket with low friction
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
ÆÆ
PBT tubes containing 4-12 optical fibers
ÆÆ
Smallest diameter for blowing into 12 mm (ID) ducts
8T x 12F
96
12
12
8
4
8.6
59
12T x 12F
144
12
12
12
0
8.6
62
2500
600
1000
Other fiber counts available on demand
Features
Available colors Operating temperature
T-Telecom (according to IEC 60304) - Fibers 1
2
3
4
5
6
7
8
9
10
11
12
+100
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
9
10
11
12
T-Telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
-30°C
Code Color
-15°C -40°C
red
green
blue
white
violet
orange
*In case of lower fiber count some tubes can be replaced by fillers.
60 | Microduct MK-LX8
grey
yellow
brown
pink
black
aqua -100
TRANSPORT
red
temperature [°C]
Color
OPERATION
+70°C +55°C
Code
INSTALLATION
1-12
microduct
MICRODUCT MK-LX9
MK-LX9 Cable structure 1. HDPE outer jacket 2. Loose tubes (PBT) with colored fibers in filling gel 3. Fillers 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord
1
3
2
4
5 6
7 Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LX9 Total elements
Active tubes
Fillers
±10% [kg/km]
14T x 12F
168
12
18
14
4
9.2
62
16T x 12F
192
12
18
16
2
9.2
63
18T x 12F
216
12
18
18
0
9.2
64
Max. tensile load [N] installation
750
operation
250
Applications Crush [N/10 cm]
1000
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
Other fiber counts available on demand
Features
Available colors T-Telecom (according to IEC 60304) - Fibers 1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
ÆÆ
PBT tubes containing up to 12 optical fibers
ÆÆ
Smallest diameter for blowing into 12 mm (ID) ducts
Operating temperature
T-Telecom (according to IEC 60304) - Tubes Tube
Loose tubes (and fillers), SZ stranded around the CSM
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
+100 +70°C +55°C INSTALLATION
Color
HDPE, UV stabilized outer jacket with low friction
ÆÆ
temperature [°C]
1-12
ÆÆ
-15°C
TRANSPORT
Fibers
Nominal weight
Ø ± 5% [mm]
OPERATION
Version
Fibers per tube
-30°C -40°C
-100
Microduct MK-LX9 | 61
microduct
MICRODUCT MK-LX11
MK-LX11 Cable structure 1. HDPE outer jacket 2. Fillers 3. Loose tubes (PBT) with colored fibers in filling gel 4. Central strength member (FRP) 5. Water blocking yarns on FRP 6. Water blocking yarns on strand element 7. Ripcord
1 2 3 4
5 6
7
Optimal Diameter
Low Friction
Blowing installation
Telecom
Microduct Generation 1
Configuration
MetroJET MK-LX11 Version
Fibers per tube
Fibers
Total elements
Active tubes
Fillers
Nominal weight
Ø ± 5% [mm]
±10% [kg/km]
20T x 12F
240
12
24
20
4
10.8
85
22T x 12F
264
12
24
22
2
10.8
86
24T x 12F
288
12
24
24
0
10.8
87
Max. tensile load [N] installation
900
operation
350
Applications Crush [N/10 cm]
1000
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
Other fiber counts available on demand
Features
Available colors
ÆÆ
HDPE, UV stabilized outer jacket with low friction
T-Telecom (according to IEC 60304) - Fibers
ÆÆ
Loose tubes (and fillers), SZ stranded around the CSM
ÆÆ
PBT tubes containing up to 12 optical fibers
ÆÆ
Smallest outer diameter for blowing into 12 mm (ID) ducts
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Operating temperature
T-Telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
+100 +70°C +55°C
-15°C -30°C -40°C
-100
62 | Microduct MK-LX11
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
temperature [°C]
-5°C
-30°C -40°C
-100
TRANSPORT
OPERATION
INSTALLATION
Telecom Duct
+100
+70°C +55°C
telecom duct
TELECOM DUCT BDC-MSA
bdc-MSA
1
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. PET tape 4. Water blocking yarns on FRP 5. Central strength member (FRP) 6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord Basic Rodent Protection
Telecom
2 3
7 4
5
6 8
Duct
Configuration
telecom duct BDC-msa Version
Fibers
1T x 12F
12
1-6T x 4F
4-24
1T x 6F
6
2T x 6F
12
2T x 12F
24
Fibers per tube
Total elements
12
Ø ± 5% [mm]
Active tubes
Max. tensile load [N]
Nominal weight PE ±5% [kg/km]
8.2
installation
operation
1500
550
50
Applications Crush
[N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
6
1
4
6
1-6
8.2
50
1550
780
6
6
1
8.2
50
1550
780
6
6
2
8.2
50
1550
780
12
6
2
8.2
51
1500
550
ÆÆ
HDPE outer jacket
Features
4T x 6F
24
6
6
4
8.2
51
1550
780
ÆÆ
Optical fibers
3T x 12F
36
12
6
3
8.2
52
1500
550
ÆÆ
Jelly into the Loose tube
6T x 6F
36
6
6
6
8.2
53
1550
780
ÆÆ
4T x 12F
48
12
6
4
8.2
53
1500
550
Loose tubes (PBT Ø 1.8 mm) with filling compound
ÆÆ
PET tape to prevent moisture into the cable
5
8.2
54
1500
550
6
8.2
54
1500
550
8T x 4F
48
4
8
8
9.3
70
1650
750
8T x 12F
96
12
8
8
9.3
71
1620
750
11T x 12F
132
12
12
11
11.5
102
1620
850
12T x 12F
144
12
12
12
11.5
104
1620
850
13T x 12F
156
12
14
13
12.6
126
2100
850
14T x 12F
168
12
14
14
12.6
126
2100
850
Operating temperature +100 +70°C
Other fiber counts available on demand
-40°C
T-Telecom (according to IEC 60304) - Fibers
-100
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
t-telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
-5°C -20°C
Available colors 1-12
+55°C
*In case of lower fiber count some tubes can be replaced by fillers.
64 | telecom duct BDC-MSA
TRANSPORT
6 6
OPERATION
12 12
INSTALLATION
60 72
temperature [°C]
5T x 12F 6T x 12F
1500
telecom duct
TELECOM BDC-MIB
BDC-MIB
1
Cable structure
Basic Rodent Protection
Telecom
1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)
Duct
6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord
2 5
3
4
7 6 8
Configuration
telecom duct BDC-MIB Version
Fibers
Fibers per tube
Total elements
Ø ± 5% [mm]
Active tubes
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
Applications Crush [N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
1-6T x 6F
6-36
6
6
1-6
8.8
63
2800
1500
1-6T x 12F
12-72
12
6
1-6
8.8
66
2800
1000
8T x 6F
48
6
8
8
10.0
77
2800
1500
8T x 12F
96
12
8
8
10.0
82
2800
1000
12T x 12F
144
12
12
12
12.2
117
2800
1000
ÆÆ
FRP strength and anti-buckling rod
16-18T x 12F
192-216
12
18
16-18
12.6
122
2800
1000
ÆÆ
Dry yarns to prevent moisture into the cable
20-24T x 12F
240-288
12
24
20-24
14.2
156
2800
1000
ÆÆ
Loose tubes (PBT Ø 1,8mm) with filling compound
ÆÆ
Optical fibers
ÆÆ
Fibreglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
Features
1500
Other fiber counts available on demand Available colors T-Telecom (according to IEC 60304) - Fibers 1
2
3
4
5
6
7
8
9
10
11
12
Operating temperature
Code blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
9
10
11
12
t-telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
PE Black RAL 9005
aqua
+70°C +55°C
-15°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color
+100
INSTALLATION
1-12
-40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom duct BDC-MIB | 65
telecom duct
TELECOM DUCT BDC-C0
BDC-c0
1
Cable structure
Basic Rodent Protection
Telecom
6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord
1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)
Duct
2 5
3
4
7 6 8
Configuration
telecom duct bdc-c0 Version
Fibers per tube
Fibers
Total elements
Ø ± 5% [mm]
Active tubes
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
Applications Crush [N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
1T x 4F
4
4
6
1
1T x 6F
6
6
6
2
2T x 6F
12
6
6
2
4T x 6F
24
6
6
4
1T x 12F
12
12
6
1
2T x 12F
24
12
6
2
ÆÆ
FRP strength and anti-buckling element
3T x 12F
36
12
6
3
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
10.0
71
2100
1300
10.0
71
2100
1300
Features
1000
4T x 12F
48
12
6
4
5T x 12F
60
12
6
5
6T x 12F
72
12
6
6
8T x 12F
96
12
8
8
11.3
97
2100
1000
12T x 12F
144
12
12
12
13.8
144
2200
1100
16T x 12F
192
12
18
16
14.2
148
2200
1100
18T x 12F
216
12
18
18
14.2
150
2200
1100
24T x 12F
288
12
24
24
16.2
190
2500
1200
2000
Operating temperature +100 +70°C +55°C temperature [°C]
Other fiber counts available on demand Available colors T-Telecom (according to IEC 60304) - Fibers 1-12
1
2
3
4
5
6
7
8
9
10
11
12 -40°C
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
t-telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
66 | telecom duct BDC-C0
-100
TRANSPORT
2000
OPERATION
74
INSTALLATION
10.0
telecom duct
TELECOM BDC-CI
BDC-CI
1
Cable structure
Basic Rodent Protection
Telecom
1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)
Duct
6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcord
2 5
3
4
7 6
Configuration
8
telecom duct bdc-cI Max. tensile load [N]
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
installation
operation
10.0
74
2800
1700
10.0
74
2800
1700
4
4
6
1
1T x 6F
6
6
6
1
2T x 6F
12
6
6
2
1T x 12F
12
12
6
1
10.0
73
2700
1200
4Tx 6F
24
6
6
4
10.0
74
2800
1600
2T x 12F
24
12
6
2
10.0
75
2700
1200
3Tx 12F
36
12
6
3
4T x 12F
48
12
6
4
10.0
82
2700
1200
6T x 12F
72
12
6
6
8T x 12F
96
12
8
8
11.4
101
2700
1200
12T x 12F
144
12
12
12
13.8
146
13T x 12F
156
12
18
13
14.2
149
14T x 12F
168
12
18
14
14.2
150
15T x 12F
180
12
18
15
14.2
151
16T x 12F
192
12
18
16
14.2
152
17T x 12F
204
12
18
17
14.2
153
18T x 12F
216
12
18
18
14.2
154
24T x 12F
288
12
24
24
16.3
191
2700
2900
Applications
2000
1200
3
4
5
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
+100
2900
+70°C +55°C
1400 temperature [°C]
6
7
8
9
10
11
-15°C
12 -40°C
Code Color
ÆÆ
Operating temperature
T-Telecom (according to IEC 60304) - Fibers 2
High tensile and crush performance
1400
Available colors 1
Installation into existing ducts
ÆÆ
Features
Other fiber counts available on demand
1-12
ÆÆ
TRANSPORT
1T x 4F
Crush [N/10 cm]
OPERATION
Fibers
INSTALLATION
Version
Fibers per tube
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
9
10
11
12
-100
t-telecom (according to IEC 60304) - Tubes Tube
1
Code PE Black Color
red
2
3
RAL 9005 green
4
5
6
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
telecom duct BDC-CI | 67
telecom duct
TELECOM DUCT BDC-CK
BDC-ck
1
Cable structure
Basic Rodent Protection
Telecom
6. Loose tubes (PBT) with colored fibers 3 in filling gel 7. Fillers 7 8. Ripcord
1. HDPE outer jacket 2. Water blocking fiberglass yarns 3. Water blocking yarns 4. Water blocking tape 5. Central strength member (FRP)
Duct
2 5 4
6
Configuration
8
telecom duct bdc-ck Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight
Max. tensile load [N]
Version
Fibers
Fibers per tube
1T x 4F
4
4
6
1
10.1
77
1T x 6F
6
6
6
1
10.1
78
1T x 8F
8
8
6
1
10.1
79
1T x 10F
10
10
6
1
10.1
80
1T x 12F
12
12
6
1
10.2
81
4100
2000
2T x 6F
12
6
6
2
10.1
78
4000
2400
2T x 12F
24
12
6
2
10.2
81
4100
2000
4T x 6F
24
6
6
4
10.1
79
4000
2400
3T x 12F
36
12
6
3
10.2
82
4100
2000
6T x 6F
36
6
6
6
10.1
82
4000
2400
±10% [kg/km]
installation
operation
Crush [N/10 cm]
Applications 2400
12
6
4
10.2
83
4100
2000
8T x 6F
48
6
8
8
11.4
98
4100
2700
5T x 12F
60
12
6
5
10.2
84
6T x 12F
72
12
6
6
10.2
85
4100
2000
96
12
8
8
11.4
104
4200
2300
144
12
12
12
13.9
151
4200
2000
16T x 12F
192
12
18
16
14.1
191
18T x 12F
216
12
18
18
14.1
191
4100
1800
24T x 12F
288
12
24
24
15.9
240
4000
1900
2000
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
t-telecom (according to IEC 60304) - Tubes 1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
68 | telecom duct BDC-Ck
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
+70°C +55°C
Code
Color
FRP strength and anti-buckling element
ÆÆ
+100
T-Telecom (according to IEC 60304) - Fibers
Tube
ÆÆ
Operating temperature
Available colors
Color
Basic rodent protection
Features
Other fiber counts available on demand
1-12
Fully dielectric cable
ÆÆ
temperature [°C]
8T x 12F 12T x 12F
High tensile and crush performance
ÆÆ
-15°C -40°C
-100
TRANSPORT
48
Installation into existing ducts
ÆÆ
OPERATION
4T x 12F
ÆÆ
INSTALLATION
4000
telecom duct
TELECOM DUCT DDC-SI
ddc-SI
1
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. HDPE inner jacket 4. Water blocking yarns 5. Central strength member (FRP) 6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcords High Rodent Protection
Telecom
Duct
2 3
7
4 5
6
Direct buried 8
Configuration
telecom duct DDC-SI Version
Fibers per tube
Fibers
Total elements
Ø ± 5% [mm]
Active tubes
Nominal weight ±10% [kg/km]
Max. tensile load [N] allowed
static
1-6T x 4F
4 - 24
4
6
1-6
9.3
67
2800
800
8T x 4F
32
4
8
8
10.3
83
2700
650
1-6T x 6F
6 - 36
6
6
1-6
9.4
68
2800
800
Applications Crush [N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
High rodent protection
8T x 6F
48
6
8
8
10.4
85
2800
800
1-6T x 12F
12 - 72
12
6
1-6
9.4
73
2700
650
8T x 12F
96
12
8
8
10.4
88
2700
670
ÆÆ
FRP strength and anti-buckling element
670
ÆÆ
Optical fibers
ÆÆ
Loose tube (PBT Ø 1.6mm) with filling compound
ÆÆ
Dry yarns to prevent moisture into the cable
Available colors
ÆÆ
T-Telecom (according to IEC 60304) - Fibers
Fiberglass yarns as tensile and water absorbent elements
ÆÆ
Double HDPE jacket
ÆÆ
LSOH, PA etc. outer jacket option
12T x 12F
144
12
12
12
12.3
122
2800
2000
Features
Other fiber counts available on demand
1-12
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Operating temperature +100
t-telecom (according to IEC 60304) - Tubes 3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
+70°C +55°C
-15°C
TRANSPORT
2
OPERATION
1
temperature [°C]
Tube
INSTALLATION
Color
-40°C
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-100
telecom duct DDC-SI | 69
telecom duct
TELECOM DUCT DDC-CI
ddc-ci
1
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. HDPE inner jacket 4. Water blocking yarns 5. Central strength member (FRP)
6. Loose tubes (PBT) with colored fibers in filling gel 7. Fillers 8. Ripcords
2 3
7
4 5
6 High Rodent Protection
Telecom
Hi-crush
Direct buried
Duct
8 Configuration
telecom duct DDC-ci Version
Fibers per tube
Fibers
Total elements
Ø ± 5% [mm]
Active tubes
Nominal weight ±10% [kg/km]
Max. tensile load [N] allowed
static
1-6T x 4F
4 - 24
4
6
1-6
11.7
73
4400
2600
1-6T x 6F
6 - 36
6
6
1-6
11.7
73
4400
2600
1-6T x 12F
12 - 72
12
6
1-6
11.8
105
4100
2000
Applications Crush [N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
High rodent protection
8T x 6F
48
6
8
8
13.0
124
4100
2300
8T x 12F
96
12
8
8
13.0
128
4100
2000
12T x 12F
144
12
12
12
15.5
180
4600
2200
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns and tape to prevent moisture into the cable
ÆÆ
Glass yarns as tensile elements
ÆÆ
Double HDPE jacket
ÆÆ
LSOH, PA etc. outer jacket option
16T x 12F
192
12
16
16
15.9
185
4600
2200
18T x 12F
216
12
18
18
15.9
187
4600
2200
24T x 12F
288
12
24
24
17.9
193
5000
2600
Features
3500
Other fiber counts available on demand
Available colors
Operating temperature
T-Telecom (according to IEC 60304) - Fibers 4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
t-telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code Color
*In cable with a multi-layer construction color of the tubes will be repeated in second layer **In case of lower fiber count some tubes can be replaced by fillers
70 | telecom duct DDC-ci
+100 +70°C +55°C
-15°C -40°C
-100
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
Telecom Aerial
telecom aerialAero-DF03 Cable structure 1. PE jacket 2. Ripcord 3. Water blocking yarns
Last mile connection outdoor
Aerial
1
4. Central Loose tube (PBT) with 250 µm colored fibers in filling gel 5. FRP strength member
2 4
3
5
Telecom
Hi-crush
FTTH
TELECOM AERIAL Aero-DF03
Cable variants Version
AERO-DF03
AERO-DF03
Fiber count
1-12
16-24
Cable dimensions [mm]
8.3 x 4.6 (±3%)
8.7 x 5.0 (-3%)
Cable weight [kg/km]
37
38
Max. installation tension[N]
1300
1300
Applications
Mechanical and enviromental characteristics
ÆÆ
Installation on poles or walls
ÆÆ
Can be installed in pipelines
ÆÆ
Fully dielectric cable
Parameter Crush performance
5000 N
Bending performance
10 cycles [20 x D]
Water Penetration
3 m sample, 1 m head, 24 h
Features ÆÆ
Loose tube with filling compound (PBT)
ÆÆ
Up to 24 fibers in a cable
Available colors
ÆÆ
Two FRP strength elements
T-Telecom (according to IEC 60304) - Fibers in tube
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Ripcord yarns For easy jacket removal
ÆÆ
PE UV resistant Jacket
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Code
Operating temperature +100
Code white
violet
orange
grey
yellow
brown
pink
natural
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm NESC Light
aqua
-15°C
TRANSPORT
blue
OPERATION
green
INSTALLATION
red
temperature [°C]
Color
+70°C +55°C
span: 120 m
-40°C
sag: 2.4 m
-100
NSC Medium span: 70 m
sag: 1.4 m
NESC Heavy span: 40 m
sag: 0.8 m
72 | telecom AERIAL Aero-DF03
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS02 2.0 mm
TELECOM AERIAL Aero-AS02 2.0 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
6
2 3 4
7
5
8
Configuration
AERO-AS02 PBT TUBES 2.0 mm Version 1-6T x 6F
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Tensile load [N] allowed
static
6 – 36
6
6
1–6
10.0
73
2200
1200
1-6T x 12F 12 – 72
12
6
1–6
10.0
75
2100
1000
8T x 12F
96
12
8
8
11.3
98
2200
1100
12T x 12F
144
12
12
12
13.8
143
2100
1000
Applications Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
2000
Other fiber counts available on demand
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction) NESC Light span: 130 m
sag: 2.6 m
NSC Medium span: 85 m
PE Black RAL 9005
sag: 1.7Grey m LSOH RAL 7022 LSOH Light Grey RAL 7037
NESC Heavy span: 45 m
sag: 0.9 m
telecom AERIAL AERO-AS02 2.0 mm | 73
telecom aerialAero-AS03 2.0 mm
TELECOM AERIAL Aero-AS03 2.0 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
2
6
3 4 7
5
8
Configuration
AERO-AS02 PBT TUBES 2.0 mm Version
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
1-6T x 6F
6-36
6
6
1-6
10.0
1-6T x 12F
12-72
12
6
1-6
8T x 12F
96
12
8
12T x 12F
144
12
12
Tensile load [N] allowed
static
75
3200
1800
10.1
77
3100
1500
8
11.3
100
3100
1500
12
13.8
146
3100
1500
Crush
[N/10 cm]
2000
Applications ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
Other fiber counts available on demand Available colors Features
T-Telecom (according to IEC 60304) - Fibers 3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
t-telecom (according to IEC 60304) - Tubes Tube
1
2
3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
*In case of lower fiber count some tubes can be replaced by fillers.
black
aqua
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C temperature [°C]
span: 190 m
sag: 3.8 m
NSC Medium span: 130 m
sag: 2.6 m
NESC Heavy span: 75 m
sag: 1.5 m
74 | telecom AERIAL AERO-AS03 2.0 mm
+55°C TRANSPORT
2
OPERATION
1
INSTALLATION
1-12
-15°C -40°C
PE Black RAL 9005
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS03 2.5 mm
TELECOM AERIAL Aero-AS03 2.5 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
2
6
3 4 7
5
8
Configuration
AERO-AS03 PBT TUBES 2.5 mm Version
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
11.4
97
3300
2200
1-6T x 12F
12-72
12
6
1-6
11.4
98
3200
2100
8T x 12F
96
12
8
8
13.0
127
3200
2100
12T x 12F
144
12
12
12
16.1
193
3300
2200
Applications Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
3000
Other fiber counts available on demand
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium span: 140 m
PE Black RAL 9005
sag: 2.8 m LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
TRANSPORT
OPERATION
+55°C INSTALLATION
sag: 3.8 m
temperature [°C]
span: 190 m
-15°C -40°C
-100
NESC Heavy span: 80 m
sag: 1.6 m
telecom AERIAL AERO-AS03 2.5 mm | 75
telecom aerialAero-AS04 2.0 mm
TELECOM AERIAL Aero-AS04 2.0 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
2
6
3 4 7
5
8
Configuration
AERO-AS04 PBT TUBES 2.0 mm Version
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1T x 12F
12
12
6
1
10,1
75
4000
2000
2T x 6F
12
6
6
2
10,1
75
4100
2400
2T x 12F
24
12
6
2
10,1
76
4000
2000
4T x 6F
24
6
6
4
10,1
76
4100
2400
3T x 12F
36
12
6
3
10,1
80
4000
2000
6T x 6F
36
6
6
6
10,1
76
4100
2400
4T x 12F
48
12
6
4
10,1
80
4000
2000
8T x 6F
48
6
8
8
11.3
97
4200
2500
6T x 12F
72
12
6
6
10,1
82
4000
2000
8T x 12F
96
12
8
8
11,4
103
4200
12T x 12F
144
12
12
12
13,9
149
4100
Other fiber counts available on demand
Applications Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
Features
2000 ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
2100
ÆÆ
Optical fibers
2000
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NSC Light
+70°C
NSC Medium span: 170 m
PE Black RAL 9005
TRANSPORT
OPERATION
+55°C INSTALLATION
sag: 5.0 m
temperature [°C]
span: 250 m
-15°C -40°C
-100
LSOH RAL 7022PELSOH BlackLight RAL 9005 Grey RAL 7037 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 sag: 3.4Grey m
NSC Heavy span: 95 m
sag: 1.9 m
76 | telecom AERIAL AERO-AS04 2.0 mm
telecom aerialAero-AS04 2.5 mm
TELECOM AERIAL Aero-AS04 2.5 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
2
6
3 4 7
5
8
Configuration
AERO-AS04 PBT TUBES 2.5 mm Version
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
11.4
98
4200
2900
1-6T x 12F
12-72
12
6
1-6
11.4
99
4100
2600
8T x 12F
96
12
8
8
13.1
128
4200
2800
12T x 12F
144
12
12
12
16.2
194
4100
2700
Applications Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
3000
Other fiber counts available on demand
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium span: 190 m
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 sag: 3.8 m
TRANSPORT
OPERATION
+55°C INSTALLATION
sag: 5.2 m
temperature [°C]
span: 260 m
-15°C -40°C
-100
NESC Heavy span: 110 m
sag: 2.2 m
telecom AERIAL AERO-AS04 2.5 mm | 77
telecom aerialAero-AS06 2.0 mm
TELECOM AERIAL Aero-AS06 2.0 mm 1
Cable structure
Aerial
Telecom
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
6. Fillers 7. Water blocking tape 8. Ripcord
2
6
3 4 7
5
8
Configuration
AERO-AS06 PBT TUBES 2.0 mm Qnt Version Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
10.2
82
6100
3600
1-6T x 12F
12
12
6
1-6
10.3
88
6200
3000
8T x 12F
96
12
8
8
11.5
110
6200
2800
12T x 12F
144
12
12
12
13.9
154
6100
3000
Applications Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
2000
Features
Other fiber counts available on demand ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium
NESC Heavy span: 140 m
sag: 2.8 m
78 | telecom AERIAL Aero-AS06 2.0 mm
TRANSPORT
-15°C -40°C
span: 250 m
sag: 5.0 m
OPERATION
sag: 7.2 m
+55°C INSTALLATION
temperature [°C]
span: 360 m
PE Black RAL 9005
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS06 2.5 mm
TELECOM AERIAL Aero-AS06 2.5 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
2
6
3 4 7
5
8
Configuration
AERO-AS06 PBT TUBES 2.5 mm Version
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
11.6
101
6100
4200
1-6T x 12F
12-72
12
6
1-6
11.6
104
6300
4100
8T x 12F
96
12
8
8
13.2
132
6100
4000
12T x 12F
144
12
12
12
16.2
198
6100
4000
Applications Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
3000
Other fiber counts available on demand
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.5 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium span: 270 m
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 sag: 5.4 m
TRANSPORT
OPERATION
+55°C INSTALLATION
sag: 7.4 m
temperature [°C]
span: 370 m
-15°C -40°C
-100
NESC Heavy span: 150 m
sag: 3.0 m
telecom AERIAL Aero-AS06 2.5 mm | 79
telecom aerialAero-AS09 2.5 mm
TELECOM AERIAL Aero-AS09 2.5 mm 1
Cable structure
Aerial
Telecom
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
6. Fillers 7. Water blocking tape 8. Ripcord
2
6
3 4 7
5
8
Configuration
AERO-AS09 PBT TUBES 2.5 mm Qnt Version Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
11.6
101
9300
6600
1-6T x 12F
12-72
12
6
1-6
11.7
104
9200
6000
8T x 12F
96
12
8
8
13.2
138
9200
6100
12T x 12F
144
12
12
12
16.2
203
9200
6100
Applications Crush
[N/10 cm]
3000
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
ÆÆ
UV resistant
Other fiber counts available on demand
Features ÆÆ
FRP strength and anti-buckling element Ø 2.5 mm
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Aramid yarns as tensile elements
Operating temperature +100 +70°C
sag: 10.6 m
TRANSPORT
span: 530 m
+55°C OPERATION
temperature [°C]
NESC Light
INSTALLATION
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
-15°C -40°C
NSC Medium span: 400 m
-100
sag: 8.0 m
NESC Heavy span: 230 m
sag: 4.6 m
80 | telecom AERIAL Aero-AS09 2.5 mm
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS12 2.5 mm
TELECOM AERIAL Aero-AS12 2.5 mm 1
Cable structure
Aerial
Telecom
6. Fillers 7. Water blocking tape 8. Ripcord
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
2
6
3 4 7
5
8
Configuration
AERO-AS12 PBT TUBES 2.5 mm Version
Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
11.7
106
12700
9000
1-6T x 12F
12-72
12
6
1-6
11.8
110
12500
8000
8T x 12F
96
12
8
8
13.3
143
12200
7800
12T x 12F
144
12
12
12
16.3
208
12100
8000
Applications Crush
[N/10 cm]
3000
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
ÆÆ
UV resistant
Other fiber counts available on demand Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Aramid yarns as tensile elements
Operating temperature +100 +70°C
sag: 14 m
TRANSPORT
OPERATION
span: 700 m
+55°C INSTALLATION
NESC Light
temperature [°C]
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
-15°C -40°C
NSC Medium span: 530 m
-100
PE Black RAL 9005
sag: 10.6 m LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
NESC Heavy span: 310 m
sag: 6.2 m
telecom AERIAL Aero-AS12 2.5 mm | 81
telecom aerialAero-AS14 2.5 mm
TELECOM AERIAL Aero-AS14 2.5 mm 1
Cable structure
Aerial
Telecom
1. HDPE outer jacket 2. Aramid yarns 3. Central strength member (FRP) 4. Loose tubes (PBT) with colored fibers in filling gel 5. Water blocking yarns
FTTH
6. Fillers 7. Water blocking tape 8. Ripcord
2
6
3 4 7
5
8
Configuration
AERO-AS14 PBT TUBES 2.5 mm Qnt Version Fibers
Fibers per tube
Total elements
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] installation
operation
1-6T x 6F
6-36
6
6
1-6
11.8
109
14400
10100
1-6T x 12F
12-72
12
6
1-6
11.8
113
14500
9400
8T x 12F
96
12
8
8
13.4
147
14200
9100
12T x 12F
144
12
12
12
16.4
211
14000
9200
Applications Crush
[N/10 cm]
3000
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
ÆÆ
UV resistant
Other fiber counts available on demand
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Aramid yarns as tensile elements
Operating temperature +100 +70°C
sag: 16.0 m
TRANSPORT
span: 800 m
+55°C OPERATION
temperature [°C]
NESC Light
INSTALLATION
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
-15°C -40°C
NSC Medium span: 600 m
-100
sag: 12.0 m
NESC Heavy span: 350 m
sag: 7.0 m
82 | telecom AERIAL AERO-AS14 2.5 mm
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Special Cable Designs
special design FTTA-DAC
special design FTTA-DAC 1
Cable structure 1. Outer jacket PE 2. Fiberglass yarns 3. Loose tube (PBT) with colored fibers in filling gel 4. Ripcords 5. Embedded strength members (FRP)
2
5
3
4
FTTA
Hi-crush
Aerial
Compact design
Configuration
FTTA-DAC Version
Fibers
Fibers per tube
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
1T x 2F
2
2
5.8
31
1T x 4F
4
4
5.8
31
1T x 6F
6
1T x 8F
8
8
5.8
32
1T x 12F
12
12
5.8
32
1T x 24F
24
24
6.3
38
6
5.8
Max. tensile load [N] installation
operation
800 (ε=0.33%)
31
Crush
[N/10 cm]
250
1200 (ε=0.50%)
3500
Applications ÆÆ
Fiber to the antenna system ( FTTA)
ÆÆ
Optical access cable with fiber glass yarns reinforcement
ÆÆ
Direct buried construction
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
Features Available colors T-Telecom (according to IEC 60304) - Fibers 1
2
3
4
5
6
7
8
9
10
11
12
Code Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
white
violet
orange
grey
yellow
brown
pink
natural
aqua
Fiberglass yarns as water-blocking and strain relief elements
ÆÆ
Loose tube (PBT) with filing compound
ÆÆ
Optical fibers
ÆÆ
Embedded strength members (FRP)
Operating temperature
Code
+100 +70°C
TRANSPORT
+50°C OPERATION
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
temperature [°C]
Color
INSTALLATION
1-12
ÆÆ
-15°C -45°C
-100
PE Black RAL 9005
84 | special design FTTA-DAC
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid power+fo
BDC-CIP 1.5 mm2
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-CIP 1
5. Water blocking tape 6. Central strength member (FRP) 7. 1.5 mm2 Cu – insulated copper wire 8. Ripcord
2 3 5 4 7 6
Duct
FTTH
Basic Rodent Protection
8
Hybrid FO + Power
Configuration
BDC-CIP 1.5 mm2 Version
Fibers
Fibers Total per elements tube
Active tubes
Ø ± 5% [mm]
Nominal weight ±10% [kg/km]
Max. tensile load [N] allowed
static
Applications Crush
[N/10 cm]
ÆÆ
Installation into existing ducts or directly buried
ÆÆ
High tensile and crush performance
1T x 12F +2x1.5 mm2
12
12
6
1
10.7
127
2700
1300
1T x 12F +4x1.5 mm2
12
12
6
1
10.7
170
2700
1300
2T x 12F +1x1.5 mm2
24
12
6
2
10.7
107
2700
1300
2T x 12F +2x1.5 mm2
24
12
6
2
10.7
128
2700
1300
ÆÆ
FRP strength and anti-buckling element
2T x 12F +4x1.5 mm2
ÆÆ
Loose tube with filling compound (PBT Ø 2.2mm)
24
12
6
2
10.7
171
2700
1300
ÆÆ
Tubes with copper core
3T x 12F +2x1.5 mm2
36
12
6
3
10.7
129
2700
1300
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
UV stabilized HDPE jacket
4T x 12F +2x1.5 mm2
48
12
6
4
10.7
130
2700
1300
ÆÆ
LSOH, PA etc Jacket option
1T x 12F +6x1.5 mm2
12
12
8
1
12.1
231
2700
1300
2T x 12F +6x1.5 mm2
24
12
8
2
12.1
232
2700
1300
3T x 12F +4x1.5 mm2
36
12
8
3
12.1
190
2700
1300
4T x 12F +4x1.5 mm2
48
12
8
4
12.1
191
2700
1300
Technical copper wire characteristics Max DC resistance
12,1±0,2 Ω/km@20°C
Electric strength
3400 V DC/1 minute
Current carrying capacity
7A
Operating voltage
65V AC/DC
Conductor material
Bare copper
PE Blackcross RALsection 9005 Conductor
Operating temperature +100 +70°C
TRANSPORT
OPERATION
+55°C INSTALLATION
2700
temperature [°C]
Other fiber and copper wire counts available on demand
Features
-15°C -40°C
-100
LSOH 1,5mm2Grey RAL 7022 LSOH Light Grey RAL 7037
Insulated conductor dia.
2,2mm
Insulation material
PVC
hybrid cables BDC-CIP | 85
hybrid power+fo
BDC-CIP 0.5 mm2 H05V-U
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-CIP 1
5. Water blocking tape 6. Central strength member (FRP) 7. 0.5 mm2 Cu – insulated copper wire 8. Ripcord
2 3 5 4 7 6
Duct
FTTH
Basic Rodent Protection
8
Hybrid FO + Power
Configuration
BDC-CIP 0.5 mm2 H05V-U Max. tensile load [N] allowed
static
1T x 12F +2x0.5 mm2
12
12
6
1
10.1
89
2700
1000
1T x 12F +4x0.5 mm2
12
12
6
1
10.1
105
2700
1000
1T x 12F +5x0.5 mm2
12
12
6
1
10.1
113
2700
1000
2T x 12F +2x0.5 mm2
24
12
6
2
10.1
90
2700
1000
2T x 12F +4x0.5 mm2
24
12
6
2
10.1
106
2700
1000
3T x 12F +2x0.5 mm2
36
12
6
3
10.1
91
2700
1000
4T x 12F +2x0.5 mm2
48
12
6
4
10.1
92
2700
1000
5T x 12F +1x0.5 mm2
60
12
6
5
10.1
85
2700
1000
1T x 12F +6x0.5 mm2
12
12
8
1
11.4
127
2800
1100
2T x 12F +6x0.5 mm2
24
12
8
2
11.4
128
2800
1100
4T x 12F +4x0.5 mm2
48
12
8
4
11.4
120
2800
1100
Other fiber and copper wire counts available on demand
Technical copper wire characteristics Max DC resistance
36,0 Ω/km@20°C
Conductor material
Bare copper
Conductor cross section
0.5 mm2
Insulated conductor dia.
2.0 mm
Insulation material
PVC
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 0.5 mm2 (Ø 2.0 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.0 mm)
ÆÆ
Tape and dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
Operating temperature +100 +70°C +55°C
-15°C -40°C
-100
PE Black RAL 9005
86 | hybrid cables BDC-CIP
Applications Crush
TRANSPORT
Nominal weight ±10% [kg/km]
OPERATION
Ø ± 5% [mm]
INSTALLATION
Fibers
Active tubes
temperature [°C]
Version
Fibers Total per elements tube
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
BDC-CIP 0.75 mm2 H05V-U
hybrid power+fo
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-CIP 1
5. Water blocking tape 6. Central strength member (FRP) 7. 0.75 mm2 Cu – insulated copper wire 8. Ripcord
2 3 5 4 7 6
Basic Rodent Protection
Duct
FTTH
8
Hybrid FO + Power
Configuration
BDC-CIP 0.75 mm2 H05V-U Nominal weight ±10% [kg/km]
Max. tensile load [N] allowed
static
1T x 12F +2x0.75 mm2
12
12
6
1
10.7
99
2700
1300
1T x 12F +4x0.75 mm2
12
12
6
1
10.7
114
2700
1300
2T x 12F +2x0.75 mm2
24
12
6
2
10.7
100
2700
1300
2T x 12F +4x0.75 mm2
24
12
6
2
10.7
115
2700
1300
3T x 12F +2x0.75 mm2
36
12
6
3
10.7
101
2700
1300
4T x 12F +2x0.75 mm2
48
1T x 12F +6x0.75 mm2
12
12
8
1
12.1
147
2700
1300
2T x 12F +6x0.75 mm2
24
12
8
2
12.1
148
2700
1300
3T x 12F +4x0.75 mm2
36
12
8
3
12.1
134
2700
1300
4T x 12F +4x0.75 mm2
48
12
8
4
12.1
135
2700
1300
Applications Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 0.75mm2 (Ø 2.2mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.2mm)
ÆÆ
Tape and dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700 6
4
10.7
102
2700
1300
Other fiber and copper wire counts available on demand
Technical copper wire characteristics Max DC resistance
24.0 Ω/km@20°C
Conductor material
Bare copper
Conductor cross section
0.75 mm2
Insulated conductor dia.
2.2 mm
Insulation material
PVC
PE Black RAL 9005
Operating temperature +100 +70°C +55°C INSTALLATION
12
TRANSPORT
Ø ± 5% [mm]
OPERATION
Fibers
Active tubes
temperature [°C]
Version
Fibers Total per elements tube
-15°C -40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid cables BDC-CIP | 87
BDC-CIP 1.00 mm2 H05V-U
hybrid power+fo
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-CIP 1
5. Water blocking tape 6. Central strength member (FRP) 7. 1.0 mm2 Cu – insulated copper wire 8. Ripcord
2 3 5 4 7 6
Basic Rodent Protection
Duct
FTTH
8
Hybrid FO + Power
Configuration
BDC-CIP 1.0 mm2 H05V-U Max. tensile load [N] allowed
static
1T x 12F +2x1.00 mm2
12
12
6
1
10.7
104
2700
1300
1T x 12F +4x1.00 mm2
12
12
6
1
10.7
124
2700
1300
2T x 12F +2x1.00 mm2
24
12
6
2
10.7
105
2700
1300
2T x 12F +4x1.00 mm2
24
12
6
2
10.7
125
2700
1300
3T x 12F +2x1.00 mm2
24
12
6
2
10.7
125
2700
1300
4T x 12F +2x1.00 mm2
48
12
6
4
10.7
107
2700
1300
5T x 12F +1x1.00 mm2
60
12
6
5
10.7
98
2700
1300
1T x 12F +6x1.00 mm2
12
12
8
1
12.1
162
2700
1300
1T x 12F +6x1.00 mm2
12
12
8
1
12.1
162
2700
1300
2T x 12F +6x1.00 mm2
24
12
8
2
12.1
163
2700
1300
3T x 12F +4x1.00 mm2
36
12
8
3
12.1
144
2700
1300
3T x 12F +4x1.00 mm2
36
12
8
3
12.1
144
2700
1300
4T x 12F +4x1.00 mm2
48
12
8
4
12.1
145
2700
1300
Other fiber and copper wire counts available on demand
Applications Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
2700
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 1.00 mm2 (Ø 2.3 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.2 mm)
ÆÆ
Tape and dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
Operating temperature +100 +70°C +55°C
-15°C -40°C
Technical copper wire characteristics Max DC resistance
18.1 Ω/km@20°C
Conductor material
Bare copper
Conductor cross section
1.00 mm2
Insulated conductor dia.
2.3 mm
Insulation material
PVC
88 | hybrid cables BDC-CIP
-100
TRANSPORT
Nominal weight ±10% [kg/km]
OPERATION
Ø ± 5% [mm]
INSTALLATION
Fibers
Active tubes
temperature [°C]
Version
Fibers Total per elements tube
BDC-DIP 1.5 mm2 H07V-U
hybrid power+fo
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-DIP 1
5. Water blocking tape 6. Central strength member (FRP) 7. 1.5 mm2 Cu – insulated copper wire 8. Ripcord
2 3 5 4 7 6
Basic Rodent Protection
Duct
FTTH
8
Hybrid FO + Power
Configuration
BDC-DIP 1.5 mm2 H07V-U Max. tensile load [N] allowed
static
1T x 12F +2x1.5 mm2
12
12
6
1
12.4
137
2700
1500
1T x 12F +4x1.5 mm2
12
12
6
1
12.4
166
2700
1500
2T x 12F +2x1.5 mm2
24
12
6
2
12.4
138
2700
1500
2T x 12F +4x1.5 mm2
24
12
6
2
12.4
167
2700
1500
3T x 12F +2x1.5 mm2
36
12
6
3
12.4
140
2700
1500
4T x 12F +2x1.5 mm2
48
12
6
4
12.4
141
2700
1500
5T x 12F +1x1.5 mm2
60
12
6
5
12.4
128
2700
1500
1T x 12F +6x1.5 mm2
12
12
8
1
14.2
228
3000
1800
2T x 12F +6x1.5 mm2
24
12
8
2
14.2
229
3000
1800
3T x 12F +4x1.5 mm2
36
12
8
3
14.2
202
3000
1800
4T x 12F +4x1.5 mm2
48
12
8
4
14.2
203
3000
1800
Applications [N/10 cm]
Other fiber and copper wire counts available on demand
Technical copper wire characteristics Max DC resistance
12.1 Ω/km@20°C
Conductor material
Bare copper
Conductor cross section
1.5 mm2
Insulated conductor dia.
2.8 mm
Insulation material
PVC
PE Black RAL 9005
Crush
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 1.50 mm2 (Ø 2.8 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.8 mm)
ÆÆ
Tape and dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
Operating temperature +100 +70°C +55°C TRANSPORT
Nominal weight ±10% [kg/km]
OPERATION
Ø ± 5% [mm]
INSTALLATION
Fibers
Active tubes
temperature [°C]
Version
Fibers Total per elements tube
-15°C -40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid cables BDC-DIP | 89
BDC-DIP 2.5 mm2 H07V-U
hybrid power+fo
Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-DIP 1
5. Water blocking tape 6. Central strength member (FRP) 7. 2.5 mm2 Cu – insulated copper wire 8. Ripcord
2 3 5 4 7 6
Basic Rodent Protection
Duct
FTTH
8
Hybrid FO + Power
Configuration
BDC-DIP 2.5 mm2 H07V-U Max. tensile load [N] allowed
static
1T x 12F +2x2.5 mm2
12
12
6
1
13.7
175
2800
1700
1T x 12F +4x2.5 mm2
12
12
6
1
13.7
223
2800
1700
2T x 12F +2x2.5 mm2
24
12
6
2
13.7
177
2800
1700
2T x 12F +4x2.5 mm2
24
12
6
2
13.7
225
2800
1700
3T x 12F +2x2.5 mm2
36
12
6
3
13.7
179
2800
1700
4T x 12F +2x2.5 mm2
48
12
6
4
13.7
180
2800
1700
5T x 12F +1x2.5 mm2
60
12
6
5
13.7
158
2800
1700
1T x 12F +6x2.5 mm2
12
12
8
1
15.7
311
2800
1700
2T x 12F +6x2.5 mm2
24
12
8
2
15.7
313
2800
1700
3T x 12F +4x2.5 mm2
36
12
8
3
15.7
267
2800
1700
4T x 12F +4x2.5 mm2
48
12
8
4
15.7
268
2800
1700
Other fiber and copper wire counts available on demand
Technical copper wire characteristics Max DC resistance
7.41 Ω/km@20°C
Conductor material
Bare copper
Conductor cross section
2.5 mm2
Insulated conductor dia.
3.3 mm
Insulation material
PVC
90 | hybrid cables BDC-DIP
Applications Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 2.50 mm2 (Ø 3.3 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 3.2 mm)
ÆÆ
Tape and dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
Operating temperature +100 +70°C +55°C
-15°C -40°C
-100
TRANSPORT
Nominal weight ±10% [kg/km]
OPERATION
Ø ± 5% [mm]
INSTALLATION
Fibers
Active tubes
temperature [°C]
Version
Fibers Total per elements tube
hybrid power+fo BDC-DID 0.8 mm Cable structure 1. HDPE outer jacket 2. Fiberglass yarns 3. Loose tubes (PBT) with colored fibers in filling gel 4. Water blocking yarns on FRP
hybrid cables BDC-DID
3
5. Water blocking tape 6. Central strength member (FRP) 7. 2x Ø 0.8/1.3 insulated Cu pair 8. Ripcord
1
2 3
5
4
6 7
Basic Rodent Protection
Duct
FTTH
8
Hybrid FO + Power
Configuration
BDC-DID 0.8 mm
1T x 12F + 7x2x0,8Cu
12
12
8
1
13.1
162
2T x 12F + 6x2x0,8Cu
24
12
8
2
13.1
161
3T x 12F + 5x2x0,8Cu
36
12
8
3
13.1
160
4T x 12F + 4x2x0,8Cu
48
12
8
4
13.1
158
5T x 12F + 3x2x0,8Cu
60
12
8
5
13.1
157
6T x 12F + 2x2x0,8Cu
72
12
8
6
13.1
156
7T x 12F + 1x2x0,8Cu
84
12
8
7
13.1
154
Max. tensile load [N] allowed
static
Applications [N/10 cm]
2900
1900
Technical copper wire characteristics PN-EN 50290-1-1:2002
Maximum resistance of wire loop
75 Ω/km@20°C
Insulation resistance
1500 MΩ·km
Material of conductor
Copper
Nominal diameter of conductor
0.8 mm
Nominal diameter of insulation
1.3 mm
Insulation material
PE
PE Black RAL 9005
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
Other fiber and copper wire counts available on demand
Standard
Crush
2000
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper pairs 2xØ 0.8/1.3 mm
ÆÆ
Loose tubes with filling compound (PBT Ø 2.5 mm)
ÆÆ
Tape and dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
Operating temperature +100 +70°C +55°C TRANSPORT
Nominal weight ±10% [kg/km]
OPERATION
Ø ± 5% [mm]
INSTALLATION
Fibers
Active tubes
temperature [°C]
Version
Fibers Total per elements tube
-15°C -40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid cables BDC-DID | 91
NOTES
92 | fiber optic cables NOTES
NOTES
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
fiber optic cables NOTES | 93
NOTES
94 | fiber optic cables NOTES
NOTES
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
fiber optic cables NOTES | 95
FIBRAIN SP. Z O.O. Rogoźnica 312 36-060 Głogów Małopolski Poland phone: (+48) 17 866-08-14 fax: (+48) 17 866-08-11 e-mail: info@fibrain.com
FIBRAIN MÉXICO Paseo de la Reforma 250 / Piso 9 Esquina c/Niza, Col. Juárez Del. Cuahtémoc México D.F. 06600 phone: (+52) 55 3600 7546 e-mail: info@fibrain.com.mx
www.fibrain.com