Trade Professional Generators 2019/2020

Page 1

R

3

GENERATORS

Page 1


TM

Any engine oil may be used ie.: SAE30, SAE40 10W50, 20W50. 5.5/6.5kW oil capacity ±500ml , 2.1/1.0kW oil capacity ±300ml.

TP 1200 4S

1.0kW 2.9HP 1.25kVA Petrol Gen Set

TP 2800 4S

TP 6000 4S

2.8kW 5.5HP 3.5kVA Petrol Gen Set

5.5kW 13HP 6.8kVA Petrol Gen Set

Domestic Use

Domestic Use

Domestic to Site Use

• Output: 1.0kW • Rated A.C. Output: 0.9kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Recoil Start • Fuel Capacity: 6L • Air Cooled • Continuous Operation Time: ±9H

• Output: 2.8kW • Rated A.C. Output: 2.5kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Recoil Start • Fuel Capacity: 15L • Automatic Regulator • Air Cooled • Continuous Operation Time: ±13H (On a full fuel tank) • 4 Stroke (Unleaded fuel) • Noise level: 65db

• Output: 5.5kW • Rated A.C. Output: 5.0kW • A.C.Frequency: 50/60Hz • Rated Voltage: 220V • Start: Recoil/Electric • Fuel Capacity: 25L • Automatic Regulator • Air Cooled • Continuous Operation Time: ±10H

(On a full fuel tank)

• 4 Stroke (Unleaded fuel) • Noise level: 65db YEAR

MCOG702

WARRANTY

x15

> 20W

> 300W

(On a full fuel tank)

YEAR WARRANTY

> 800W

> 400W

YEAR

MCOG707EW

x15

> 20W

> 400W

• Output: 6.5kW • Rated A.C. Output: 6.0kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Start: Electric • Fuel Capacity: 25L • Automatic Regulator • Air Cooled • Continuous Operation Time: ±8H • 4 Stroke (Unleaded fuel) • Noise level: 76db

MCOG706EW

x15

> 20W

> 100W

(On a full fuel tank)

WARRANTY

6.5kW 15HP 8.1kVA Petrol Gen Set Domestic to Site Use

• 4 Stroke (Unleaded fuel) • Noise level: 74db

YEAR

MCOG701A

TP 7000 4S

WARRANTY

x15

> 100W

> 300W

> 20W

> 300W

> 1000W

> 1000W

> 1200W

> 1000W

800W

1000W

3500W

4800W

N/A

400W

1000W

1200W

800W

1400W

4500W

6000W

START UP WATTAGE

RUNNING WATTAGE

> 1000W

> 1000W

REQUIRED WATTAGE

If start up wattage is not stated: • Anything with a motor has a start up wattage. • Start up wattage = ±3/4x appliance wattage. General appliances with a start up wattage:

> 20W

> 100W

> 300W

> 1000W

> 1000W

> 1000W

> 1200W

> 2000W

For most effective use:

> 1000W

> 1000W

> 1000W

> 1000W

> 1000W

* Run time may vary up to 2 - 3 hours less than stated depending on altitude level; how much load is being applied and fuel type/brand.

run at 90% in 2 hour sessions

This chart is to illustrate how to calculate your total electricity consumption by adding the highest startup wattage to the combined amount of running wattage. Rather select the next model up as fluctuation in electrical current caused by large appliances such as washing machines, can cause spikes that can be harmful to your appliances and generating set. Check your wattage consumption on the back of your electrical appliance. Please ensure that the instruction booklet or user guide provided in the packaging are well read, understood & adhered to. IMAGES ARE FOR DISPLAY PURPOSES ONLY.

Page 2


GENERATING SET INFO SHEET TP 5020 4S

7.5kW 16HP 9.4kVA Petrol Gen Set Domestic to Site Use

• Output: 5.5kW • Rated AC output: 5kW • AC Frequency: 50Hz • Rated voltage: 220V • Start: Recoil/Electric • Fuel capacity: 25L • Automatic Regulator • Oil capacity: 1.1L • Welding current: 200A • Welding electrode size: 2.5 - 5.0mm • Air Cooled • Continuous Operation Time: ±8H (On a full fuel tank) • 4 Stroke (Unleaded fuel) • Noise level: 78db

(On a full fuel tank)

• 4 Stroke (Unleaded fuel) • Noise level: 78db YEAR

MCOG708EW

WARRANTY

x15

1 YEAR

• Output: 7.5kW • Rated A.C. Output: 7.0kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Start: Recoil/Electric • Fuel Capacity: 25L • Automatic Regulator • Air Cooled • Continuous Operation Time: ±7H

TP 5025 4S

5.5kW PETROL Welding Gen Set Domestic 6.8kVA to Site Use

MCOG720EW

WARRANTY

5.5kW DIESEL Welding Gen Set 6.8kVA

• Output: 5.5kW • Rated AC output: 5kW • AC Frequency: 50Hz • Rated voltage: 220V • Start: Recoil/Electric • Fuel capacity: 25L • Automatic Regulator • Oil capacity: 1.65L • Welding current: 200A • Welding electrode size: 2.5 - 4.0mm • Air Cooled • Continuous Operation Time: ±8H (On a full fuel tank) • Noise level: 76db

1

MCOG721EW

x15

WARRANTY

x15

> 20W

> 300W

> 1000W

> 20W

> 100W

> 1000W

> 20W

> 100W

> 1200W

> 1000W

> 2000W

> 1000W

> 1200W

> 2000W

> 1000W

> 1000W

5800W

3600W

3400W

1200W

1200W

1000W

7000W

4800W

4400W

HOW TO CHOOSE THE RIGHT GENERATING SET >> > 400W

> 1000W

> 800W

> 1000W

> 1000W

> 1200W

SELECT YOUR ITEM / WATTS

1000 W = 1 kW (1.25kVA)

Domestic to Site Use

YEAR

TP 8000 4S

1. Choose the appliances that you would like to power simultaneously. 2. Record all the running Watts listed for each appliance. 3. Record the additional starting Watts listed for each appliance. 4. Add the starting Watts from the highest starting Watt appliance to the total of the running watts. 5. The total will guide you to select the correct generator set model.

> 1000W

RUNNING WATTAGE

START UP WATTAGE

1 x GLOBE

60W

60W

TELEVISION

300W

300W

MICROWAVE

1000W

1000W

REFRIDGERATOR

1000W

3000W

SELECT THE HIGHEST STARTING WATTS

2360W + 3000W

DEVICE

TOTAL

5360W

This chart is to illustrate how to calculate your total electricity consumption by adding the highest startup wattage to the combined amount of running wattage. Rather select the next model up as fluctuation in electrical current caused by large appliances such as washing machines, can cause spikes that can be harmful to your appliances and generating set. Check your wattage consumption on the back of your electrical appliance. Please ensure that the instruction booklet or user guide provided in the packaging are well read, understood & adhered to. IMAGES ARE FOR DISPLAY PURPOSES ONLY.

Page 3


GENERATORS

Any engine oil may be used ie.: SAE30, SAE40 10w50, 20w50. Oil capacity for 5.5/6.5Kw is ±500ml. Oil capacity for 2.1/1.0Kw is ±300ml. Domestic Use

TP 1200 4S - 1.0kW 2.9HP 1.25kVA Petrol Gen Set • Output: 1.0kW • Rated A.C. Output: 0.9kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Start: Recoil • Fuel Capacity: 6L • Air Cooled: Yes • Cont. Operation Time: ±9H (On a full fuel tank) • 4 Stroke (Unleaded fuel) • Noise level: 65db

• Output: 2.8kW • Rated A.C. Output: 2.5kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Start: Recoil • Fuel Capacity: 15L • Automatic Regulator: Yes • Air Cooled: Yes • Cont. Operation Time: ±13H (On a full fuel tank) • 4 Stroke (Unleaded fuel) • Noise level: 65db Code no: Barcode: MCOG701A 6003398094846

TM

YEAR

Domestic Use

TP 2800 4S - 2.8kW 5.5HP 3.5kVA Petrol Gen Set

WARRANTY

PETROL GEN SETS

Code no: Barcode: MCOG702 6003751342171

Page 4

Please note that running times can change depending on altitude level, load being applied and fuel type/brand. Running times can vary up to 2-3 hours less than stated.


GENERATORS TP 6000 4S - 5.5kW 13HP 6.8kVA Petrol Gen Set • Output: • Rated A.C. Output: • A.C.Frequency: • Rated Voltage: • Start: • Fuel Capacity: • Automatic Regulator: • Air Cooled: • Cont. Operation Time: (On a full fuel tank) • 4 Stroke • Noise level:

Domestic to Site Use

5.5kW 5.0kW 50/60Hz 220V Recoil/Electric 25L Yes Yes ±10H (Unleaded fuel) 74db

Code no: Barcode: MCOG706EW 6003751359711

TP 7000 4S - 6.5kW 15HP 8.1kVA Petrol Gen Set • Output: • Rated A.C. Output: • A.C.Frequency: • Rated Voltage: • Start: • Fuel Capacity: • Automatic Regulator: • Air Cooled: • Cont. Operation Time: (On a full fuel tank) • 4 Stroke • Noise level:

Domestic to Site Use

6.5kW 6.0kW 50Hz 220V Electric 25L Yes Yes ±8H (Unleaded fuel) 76db

Domestic to Site Use

YEAR

• Output: 7.5kW • Rated A.C. Output: 7.0kW • A.C.Frequency: 50Hz • Rated Voltage: 220V • Start: Recoil/Electric • Fuel Capacity: 25L • Automatic Regulator: Yes • Air Cooled: Yes • Cont. Operation Time: ±7H (On a full fuel tank) • 4 Stroke ( Unleaded fuel) • Noise level: 78db

Please note that running times can change depending on altitude level, load being applied and fuel type/brand. Running times can vary up to 2-3 hours less than stated.

TM

Code no: Barcode: MCOG708EW 6003398100875

Page 5

WARRANTY

TP 8000 4S - 7.5kW 16HP 9.4kVA Petrol Gen Set

PETROL GEN SETS

Code no: Barcode: MCOG707EW 6003398071007


GENERATORS

WELDING GENSETS

TP 5025 4S - 5.5kW DIESEL Welding GenSet

Domestic to Site Use

WELDING GEN SETS - DIESEL AND PETROL

• Output: 5.5kW • Rated AC output: 5kW • AC Frequency: 50Hz • Rated voltage: 220V • Start: Recoil/Electric • Fuel capacity: 25L • Automatic Regulator: Yes • Oil capacity: 1.1L • Welding current: 200A • Welding electrode size: 2.5 - 5.0mm • Air Cooled: Yes • Cont. Operation Time: ±8H (On a full fuel tank) • 4 Stroke (Unleaded fuel) • Noise level: 78db Code no: Barcode: MCOG721EW 6003398100899

TP 5020 4S - 5.5kW PETROL Welding GenSet

1

WARRANTY

• Output: 5.5kW • Rated AC output: 5kW • AC Frequency: 50Hz • Rated voltage: 220V • Start: Recoil/Electric • Fuel capacity: 25L • Automatic Regulator: Yes • Oil capacity: 1.65L • Welding current: 200A • Welding electrode size: 2.5 - 4.0mm • Air Cooled: Yes • Cont. Operation Time: ±8H (On a full fuel tank) • Noise level: 76db

YEAR TM

Code no: Barcode: MCOG720EW 6003398100882

Page 6

Domestic to Site Use


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.