INTERIOR SIGNAGE SPEC
SECTION 10440 !
! ! ! ! !
CLARITY! !
FROM CREATIVE SIGN DESIGN
A complete architectural signage system intended to simplify decision-making, Clarity removes the guesswork. The selection is organized into sign families by graphic shape and further segmented with additional features. Clients may begin the customization by selecting shape, orientation and finish materials to coordinate with interior elements, branding criteria and architect specifications.
CONTENTS Clarity Studio 1 Drawings Clarity Studio 1 Specifications Clarity Studio 2 Drawings Clarity Studio 2 Specifications Clarity Studio 3 Drawings Clarity Studio 3 Specifications Standard Colors Color Contrast Chart Fonts ADA Overview Sheets
…… ....... …... …... …… …... …… …… …… ……
4 7 18 21 33 36 48 49 50 51
Creative Sign Designs
SECTION 10440 INTERIOR SIGNAGE Clarity Studio 1 Display hidden notes to specifier. (Don't know how? Click Here)
NOTE TO SPECIFIER ** Creative Sign Designs; Interior Signage. This section is based on the products manufactured Creative Sign Designs, which is located at: 12801 Commodity Place Tampa, FL 33626 Tel: (800) 804.4809 Tel: (813) 915.1900 Fax: (813) 818.7200 Email: info@creativesigndesigns.com Website: www.creativesigndesigns.com With a consultative approach to architectural signage, Creative Sign Designs specializes in guiding people in and around places. Whether it’s guiding you through the design of a project and the selection of materials or guiding the end user to, through and around the space, we are guiding every step of the way. As a custom sign fabricator, we believe a successful program involves more than just investing in first-rate products. It requires meticulous planning and execution for the end result to be functional, cost efficient and compliant with pertinent regulations, such as the Americans with Disabilities Act (ADA). With over a quarter century of experience in the sign industry, Creative Sign Designs has the know how to successfully complete projects for clients in any industry, anywhere. PART 1GENERAL 1.1 SECTION INCLUDES ** NOTE TO SPECIFIER ** Remove items below not required for project.
1.2
A.
Room Identification.
B.
Stairs.
C.
Restroom.
D.
Elevator Lobby.
E.
Informational Signage.
F.
Directory Signage.
RELATED SECTIONS
** NOTE TO SPECIFIER ** Remove any sections below not relevant to this project; add others as required.
1.3
1.4
A.
Section 10410 - Directories.
B.
Section 10420 - Plaques.
C.
Section 10430 - Exterior Signage.
REFERENCES A.
ANSI 117.1 – For Buildings and Facilities
B.
ASTM International (ASTM) D635 - Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.
C.
ASTM International (ASTM) E84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
D.
ASTM International (ASTM) D1929 - Standard Test Method for Determining Ignition Temperature of Plastics.
E.
Underwriters Laboratories (UL) 94 - Tests for Flammability of Plastic Materials for Parts in Devices and Appliances.
F.
Underwriters Laboratories (UL) 723 - Standard for Test for Surface Burning Characteristics of Building Materials.
G.
ASTM E2072-04 - Standard Specification for Photoluminescent (Phosphorescent) Safety Marketing.
H.
ASTM E2073-02 - Standard Test Method for Photopic Luminance of Photo Luminescent (Phosphorescent) Markings.
PERFORMANCE REQUIREMENTS A.
Provide photopolymer signage that conforms to the requirements of all regulatory agencies holding jurisdiction and the quality control of CSD. ** NOTE TO SPECIFIER ** Retain the next paragraph only if glow in the dark signage is specified. B.
Provide glow in the dark, photo luminescent material that complies with applicable provisions of ASTM E 2073-02 and DIN 67510. Photo luminescent material must have up to eight hours of luminance. ** NOTE TO SPECIFIER ** Remove the next paragraph if ADA conformance is not required. C.
Requirements: 1. Comply with all applicable provisions of the ADA and ANSI A117.1-1998. 2. Character Proportion: Letters and numbers on signs must have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10. 3. Color Contrast: Characters and symbols must contrast with their background - either light characters on a dark background or dark characters on a light background. 4. Raised Characters or Symbols: Letters and numbers on signs must be raised 1/32 in (0.8 mm) minimum and be sans serif characters. Raised characters or symbols must be at least 5/8 in (16 mm) high but no higher than 2 in (50
5. 6. D.
1.5
mm). Symbols or pictograms on signs must be raised 1/32 in (0.8 mm) minimum. Symbols of Accessibility: Accessible facilities required to be identified must use the international symbol of accessibility. Braille: Grade II with accompanying text.
Fire Performance Characteristics: 1. Provide photopolymer signage with surface burning characteristics that consist of a flame spread of 75 and a smoke development of 120 when tested in accordance to UL 723 (ASTM E 84). 2. Self-Extinguishing: Provide photopolymer signage with a CC1 classification for .060 in thick material when tested in accordance with the procedures in ASTM D 635, Standard Test Method for Rate of Burning and/or Extent and Time of Burning Plastics in a Horizontal Position. 3. Vertical Burn: Provide photopolymer material that is classified as 94V-2 for material .118 in thick or greater and 94HB for material .118 in thick or less when tested in accordance with UL 94, Tests for Flammability of Plastic Materials for Parts in Devices and Appliances. 4. Self-Ignition Temperature: Provide photopolymer material that has a o o self-ignition temperature of 800 F (427 C) when tested in accordance with ASTM D 1929.
SUBMITTALS A.
Submit under provisions of Section 01300.
B.
Product Data: Manufacturer's data sheets on each product to be used including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods.
C.
Shop Drawings: Detail drawings showing sizes, lettering and graphics, construction details of each type of sign and mounting details with appropriate fasteners for specific project substrates. ** NOTE TO SPECIFIER ** Remove selection samples if colors already have been selected.
1.6
D.
Selection Samples: For each finish product specified, two sets of color sheets representing manufacturer's full range of available colors and patterns.
E.
Verification Samples: For each sign type and color specified, two samples, minimum size 6 in (150 mm) square, representing actual product, color and patterns.
F.
Manufacturer's Installation Instructions: Printed installation instructions for each signage system.
G.
Message Schedule: Signage report indicating signage location, text and sign type.
DELIVERY, STORAGE AND HANDLING A.
Deliver materials in unopened factory packaging.
B.
Inspect materials at delivery to verify there are no defects or damage.
C.
Store products in manufacturer's original packaging until ready for installation in climate controlled location away from direct sunlight.
D.
Store and dispose of solvent-based materials, and materials used with solvent-based
materials in accordance with requirements of local authorities having jurisdiction. 1.7
1.8
PROJECT CONDITIONS A.
Install products in an interior climate controlled environment.
B.
Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
WARRANTY A.
PART 2 2.1
At project closeout, provide to the Owner or Owner’s representative a copy of the manufacturer's standard limited warranty against manufacturing defect outlining the terms, conditions and exclusions from coverage. 1. Duration: One (1) year. PRODUCTS
MANUFACTURERS A.
Acceptable Manufacturer: Creative Sign Designs, 12801 Commodity Place, Tampa, FL 33626; Toll Free Tel: 800.804.4809; Tel: 813.818.7200; e-mail: info@creativesigndesigns.com; website: www.creativesigndesigns.com
B.
Substitutions: Not permitted unless bidder obtains approval from the Architect and/or Owner to bid alternates or substitutions to the specifications at least four weeks prior to bid date.
C.
Provide all signage from one manufacturer.
2.2 SIGNAGE – GENERAL ** NOTE TO SPECIFIER ** Remove products from the list below that are not required. The signage in this specification is manufactured using the photopolymer process. The specific photopolymer used in the manufacture of signage from CSD is manufactured by Nova Polymers and incorporates the use of the Novacryl product line. Novacryl is photopolymer integrally bonded to a Polyethylene Terephthalate Glycol (PETG) base. All materials must have a topcoat of acrylic polyurethane to ensure protection from cleaning agents, UV and moisture. Novacryl is fire rated for use in applications where fire hazard classification is required. A.
It is the intent of these specifications to establish a sign standard for the Owner including but not limited to primary and secondary directories, wall-mounted directional signs, primary room identification, restrooms, conference rooms, work station identification and all code compliant signage. While the Owner may not obtain all signs and sign types, the signage contractor shall design and submit approval drawings for all sign types relevant to the project.
B.
Comply with all applicable provisions of the ADAAG and ANSI A117.1 codes that apply to the State and Local jurisdiction of the project.
C.
If required text and graphics are not indicated in specification or on drawings, obtain Owner's instructions as to text and graphics prior to preparation of shop drawings.
D.
Typography: See Drawings. Copy shall be a clean and accurate reproduction of typeface(s) specified. Upper and lower case and all caps as indicated in Sign Type drawings and Signage Schedule. Letter spacing to be set by manufacturer.
E.
Arrows, symbols and pictograms will be provided in style, sizes, colors and spacing as indicated in drawings for each sign system. ** NOTE TO SPECIFIER ** Remove all but one of the following. F.
Braille 1. Grade 2 Braille 2. California Braille ** NOTE TO SPECIFIER ** Remove all but one of the following four placements. If more than one is required, indicate clearly where each will be applied. 1. Text/Graphics Placement: Right justified. 2. Text/Graphics Placement: Centered. 3. Text/Graphics Placement: Left justified. 4. Text/Graphics Placement: As indicated on contract drawings. ** NOTE TO SPECIFIER ** Remove all but one of the following 4 font options. If more than one is required, indicate clearly where each will be applied. 5. Font: As Indicated on the Contract Drawings. 6. Font: Optima Medium. 7. Font: Frutiger. 8. Font: Helvetica Bold. 9. Font: Myriad Pro. 10. Font: ________________ 2.3
IDENTIFICATION SIGNAGE
A. System: Clarity: Studio 1. ** NOTE TO SPECIFIER ** Make one selection from sections B-F and one selection from section C. If making more than one selection per section, please be specific. Remove what is not needed. B.
ADA Plate Color Selection 1. Red 101 2. Burgundy 102 3. TERRA COTTA 103 4. Yellow 104 5. Green 105 6. Pine 106 7. Forest Green 107 8. Island Blue 108 9. Blue 109 10. Royal Blue 110 11. Union Blue 111 12. Shadow Blue 112 13. Ivory 113 14. Sand 114 15. Beige 115 16. Ash 116 17. Off-White 117 18. Bright White 118 19. Birch Grey 119 20. Medium Grey 120 21. Dark Grey 121 22. Charcoal 122 23. Taupe 123 24. Stone 124 25. Mink 125
26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41.
Dark Brown 126 Black 127 Gold 128 Silver 129 Graphite 130 LAM-Biltmore Cherry LAM-Brighton Walnut LAM-Cocobala LAM-Kensington Maple LAM-Monticello Maple ECO-Aqua ECO-Banana Fiber Lite ECO-Bear Grass Lite ECO-Bronze Weave ECO-Fossil Leaf Color: ________________
C.
ADA Plate Gauge Selection 1. 1/8” 2. 1/4” 3. Other: ________________
D.
ADA Raised Copy Color Selection 1. Black 2. White 3. Gold 1255 4. Grey 430 5. Metallic silver 877 6. Tan 7501 7. Brown 7518 8. Color: _____________
E.
ADA Font Choices 1. Font: As Indicated on the Contract Drawings. 2. Font: Optima Medium. 3. Font: Frutger. 4. Font: Helvetica Bold. 5. Font: Myriad Pro. 6. Font: ________________
F.
Corner Finishes 1. Square 2. Round 3. Scallop 4. Bevel ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. Each line of copy has up to 14 characters per line (5/8” copy). G.
Sign Type – Standard Room ID 1. R.0 - Room ID - Small a. Size: 2.5” x 5.5” b. Qty: _________ 2.
R.1 - Room ID – 1 Line a. Size: 2.5” x 8.5” b. Qty: _________
3.
R.2 - Room ID – 2 Line a. Size: 3.5” x 8.5” b. Qty: _________
4.
R.3 - Room ID – 3 Line a. Size: 5.5” x 8.5” b. Qty: _________
5.
CR - Conference Room – 3 Line (In Use/Vacant Slider) a. Size: 7.5” x 8.5” b. Qty: _________
6.
RIN.0 - Room ID – Small Insert (Insert Size: 8.5”x3”) a. Size: 6.5” x 8.5” b. Qty: _________
7.
RIN.1 - Room ID – Large Insert (Insert Size: 8.5”x5.5”) a. Size: 9” x 8.5” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. Note the pictograms are 6”x6” with one line of copy. Each line of copy has up to 14 characters per line (5/8” copy). H. Sign Type – Room ID (Code Required Signage) 1. RR-M - Men a. Size: 9” x 9” b. Qty: _________ 2.
RR-W - Women a. Size: 9” x 9” b. Qty: _________
3.
RR-U - Unisex a. Size: 9” x 9” b. Qty: _________
4.
RR-MA - Men / Accessible a. Size: 9” x 9” b. Qty: _________
5.
RR-WA - Women / Accessible a. Size: 9” x 9” b. Qty: _________
6.
RR-UA - Unisex / Accessible a. Size: 9” x 9” b. Qty: _________
7.
S - Stairwell a. Size: 9” x 9” b. Qty: _________
8.
P – Misc. Pictogram a. Size: 9” x 9” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. All artwork for E.2P and E.4P Evacuation Maps are to be provided by client or architect.
Remove what is not needed. I.
Sign Type – Life Safety Signage (Code Required Signage) 1. EXIT – Exit - Up to 10 Character with 5/8” Copy a. Size: 2.5” x 5.5” b. Qty: _________ 2.
LS-MO - Informational – Up to 14 Characters Per Line with 5/8” Copy a. Size: 5.5” x 8.5” b. Qty: _________
3.
LS-F - Fire Extinguisher - Up to 14 Characters Per Line with 5/8” Copy a. Size: 5.5” x 8.5” b. Qty: _________
4.
LS-S - In Case of Fire - Up to 14 Characters Per Line with 5/8” Copy a. Size: 9” x 9” b. Qty: _________
5.
L - Level Indicator a. Size: 14” x 12” b. Qty: _________
6.
E.2P - Evacuation Map (Insert Size: 8.5”x11”) a. Size: 14.5” x 8.5” b. Qty: _________
7.
E.4P - Evacuation Map (Insert Size: 11”x17”) a. Size: 20.5” x 11” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. J.
Sign Type – Work Station and Miscellaneous Inserts 1. IN.0 – Extra Small Inserts (Insert Size 8.5”x3”) a. Size: 4” x 8.5” b. Qty: _________ 2.
IN.1L – Small Landscape Insert (Insert Size: 8.5”x5.5”) a. Size: 6.5” x 8.5” b. Qty: _________
3.
N.2L – Letter Landscape Inserts (Insert Size: 8.5”x11”) a. Size: 9.5” x 11” b. Qty: _________
4.
IN.3L – Legal Landscape Insert (Insert Size: 8.5”x14”) a. Size: 9.5” x 14” b. Qty: _________
5.
IN.4L – Tabloid Landscape Insert (Insert Size: 11”x17”) a. Size: 12” x 17” b. Qty: _________
6.
IN.1P - Small Portrait Insert (Insert Size: 8.5”x5.5”) a. Size: 9.5” x 5.5” b. Qty: _________
7.
IN.2P - Letter Portrait Insert (Insert Size: 8.5”x11”) a. Size: 12” x 8.5” b. Qty: _________
8.
IN.3P – Legal Portrait Insert (Insert Size: 8.5”x14”) a. Size: 15” x 8.5” b. Qty: _________
9.
IN.4P – Tabloid Portrait Insert (Insert Size: 11”x17”) a. Size: 18” x 11” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. K.
Sign Type – Wall Directionals 1. WD.2P-1 - Single Insert Directory - 1 Slot with 5/8” Copy (Insert Size: 8.5”x11”) a. Size: 14.5” x 8.5” b. Qty: _________ 2.
WD.2P-5 - Single Insert Directory – 5 Slots with 5/8” Copy (Insert Size: 8.5”x2”) a. Size: 14.5” x 8.5” b. Qty: _________
3.
WD.2P-9 - Single Insert Directory - 9 Slots with 5/8” Copy (Insert Size: 8.5”x1”) a. Size: 14” x 8.5” b. Qty: _________
4.
WD.4P-1 - Single Insert Directory - 1Slot with 1” Copy (Insert Size: 11”x17”) a. Size: 20.5” x 11” b. Qty: _________
5.
WD.4P-9 - Single Insert Directory - 9 Slots with 5/8” Copy (Insert Size: 11”x7.5”) a. Size: 20.5” x 11” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. L.
Sign Type – Flagmounts 1. F-L - Flagmount Landscape Double Sided a. Size: 5” x 15.57” b. Qty: _________ 2.
F-P - Flagmount Portrait Double Sided a. Size: 5” x 16” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. There must be 80” clearance from the floor to the bottom on the signs in this section. ADA requires at least 3” copy on directionals. M.
Sign Type – Overhead Directionals 1. OD.8-48 - Overhead Directory Standard - Double Sided with Up To 2 Lines of Copy
a. b.
Size: 8” x 48” Qty: _________
2.
OD.12-48 - Overhead Directory Standard – Double Sided with up to 3 Lines of Copy a. Size: 12” x 48” b. Qty: _________
3.
OD.8-72 - Overhead Directory Large – Double Sided with up to 2 Lines of Copy a. Size: 8” x 72” b. Qty: _________
4.
OD.12-72 - Overhead Directory Large – Double Sided with up to 2 Lines of Copy a. Size: 12” x 72” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. N.
Sign Type – Directories 1. D.1 - Single Insert Directory – Single Insert with 1.25” Copy (Insert Size: 22’x30”) a. Size: 36” x 22” b. Qty: _________ 2.
D.12- Multiple Insert Directory – 12 Slots with 1.25” Copy (Insert Size: 22”x2”) a. Size: 36” x 22” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required mounting method. Remove what is not needed. O.
Mounting 1. Double face tape and silicone mount. 2. Mechanical, tamper resistant fasteners.
P.
EXECUTION 1. EXAMINATION a. Verify that wall surface is dry and free from dirt, grease and loose paint. b. Complete all finishing operations, including painting, before beginning installation of signage systems. c. Do not begin installation until substrates have been properly prepared. d. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. e. Examine signage for defects prior to installation. Do not install damaged signage. 2.
PREPARATION a. Verify mounting heights and locations comply with referenced standards. b. Clean surfaces thoroughly prior to installation to remove dust, debris and loose particles. c. Prepare surfaces using the methods recommended by the
manufacturer for achieving the best results for the substrate under the project conditions. 3.
INSTALLATION a. Locate the signage system as indicated on drawings for the appropriate substrate and in accordance with manufacturer's installation instructions. b. Install signage systems level and plumb at the height indicated on the drawings. c. Mount in accordance with current ADA and state regulations.
4.
CLEANING a. At completion of installation, clean surfaces in accordance with manufacturer's instructions.
5.
PROTECTION a. Protect installed products until completion of project. b. Touch up, repair or replace damaged products before substantial completion. END OF SECTION
Creative Sign Designs
SECTION 10440 INTERIOR SIGNAGE Clarity Studio 2 Display hidden notes to specifier. (Don't know how? Click Here)
NOTE TO SPECIFIER ** Creative Sign Designs; Interior Signage. This section is based on the products manufactured Creative Sign Designs, which is located at: 12801 Commodity Place Tampa, FL 33626 Tel: (800) 804.4809 Tel: (813) 915.1900 Fax: (813) 818.7200 Email: info@creativesigndesigns.com Website: www.creativesigndesigns.com With a consultative approach to architectural signage, Creative Sign Designs specializes in guiding people in and around places. Whether it’s guiding you through the design of a project and the selection of materials or guiding the end user to, through and around the space, we are guiding every step of the way. As a custom sign fabricator, we believe a successful program involves more than just investing in first-rate products. It requires meticulous planning and execution for the end result to be functional, cost efficient and compliant with pertinent regulations, such as the Americans with Disabilities Act (ADA). With over a quarter century of experience in the sign industry, Creative Sign Designs has the know how to successfully complete projects for clients in any industry, anywhere. PART 1GENERAL 1.1 SECTION INCLUDES ** NOTE TO SPECIFIER ** Remove items below not required for project.
1.2
A.
Room Identification.
B.
Stairs.
C.
Restroom.
D.
Elevator Lobby.
E.
Informational Signage.
F.
Directory Signage.
RELATED SECTIONS
** NOTE TO SPECIFIER ** Remove any sections below not relevant to this project; add others as required.
1.3
1.4
A.
Section 10410 - Directories.
B.
Section 10420 - Plaques.
C.
Section 10430 - Exterior Signage.
REFERENCES A.
ANSI 117.1 – For Buildings and Facilities
B.
ASTM International (ASTM) D635 - Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.
C.
ASTM International (ASTM) E84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
D.
ASTM International (ASTM) D1929 - Standard Test Method for Determining Ignition Temperature of Plastics.
E.
Underwriters Laboratories (UL) 94 - Tests for Flammability of Plastic Materials for Parts in Devices and Appliances.
F.
Underwriters Laboratories (UL) 723 - Standard for Test for Surface Burning Characteristics of Building Materials.
G.
ASTM E2072-04 - Standard Specification for Photoluminescent (Phosphorescent) Safety Marketing.
H.
ASTM E2073-02 - Standard Test Method for Photopic Luminance of Photo Luminescent (Phosphorescent) Markings.
PERFORMANCE REQUIREMENTS A.
Provide photopolymer signage that conforms to the requirements of all regulatory agencies holding jurisdiction and the quality control of CSD. ** NOTE TO SPECIFIER ** Retain the next paragraph only if glow in the dark signage is specified. B.
Provide glow in the dark, photo luminescent material that complies with applicable provisions of ASTM E 2073-02 and DIN 67510. Photo luminescent material must have up to eight hours of luminance. ** NOTE TO SPECIFIER ** Remove the next paragraph if ADA conformance is not required. C.
Requirements: 1. Comply with all applicable provisions of the ADA and ANSI A117.1-1998. 2. Character Proportion: Letters and numbers on signs must have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10. 3. Color Contrast: Characters and symbols must contrast with their background - either light characters on a dark background or dark characters on a light background. 4. Raised Characters or Symbols: Letters and numbers on signs must be raised 1/32 in (0.8 mm) minimum and be sans serif characters. Raised characters or symbols must be at least 5/8 in (16 mm) high but no higher than 2 in (50
5. 6. D.
1.5
mm). Symbols or pictograms on signs must be raised 1/32 in (0.8 mm) minimum. Symbols of Accessibility: Accessible facilities required to be identified must use the international symbol of accessibility. Braille: Grade II with accompanying text.
Fire Performance Characteristics: 1. Provide photopolymer signage with surface burning characteristics that consist of a flame spread of 75 and a smoke development of 120 when tested in accordance to UL 723 (ASTM E 84). 2. Self-Extinguishing: Provide photopolymer signage with a CC1 classification for .060 in thick material when tested in accordance with the procedures in ASTM D 635, Standard Test Method for Rate of Burning and/or Extent and Time of Burning Plastics in a Horizontal Position. 3. Vertical Burn: Provide photopolymer material that is classified as 94V-2 for material .118 in thick or greater and 94HB for material .118 in thick or less when tested in accordance with UL 94, Tests for Flammability of Plastic Materials for Parts in Devices and Appliances. 4. Self-Ignition Temperature: Provide photopolymer material that has a o o self-ignition temperature of 800 F (427 C) when tested in accordance with ASTM D 1929.
SUBMITTALS A.
Submit under provisions of Section 01300.
B.
Product Data: Manufacturer's data sheets on each product to be used including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods.
C.
Shop Drawings: Detail drawings showing sizes, lettering and graphics, construction details of each type of sign and mounting details with appropriate fasteners for specific project substrates. ** NOTE TO SPECIFIER ** Remove selection samples if colors already have been selected.
1.6
D.
Selection Samples: For each finish product specified, two sets of color sheets representing manufacturer's full range of available colors and patterns.
E.
Verification Samples: For each sign type and color specified, two samples, minimum size 6 in (150 mm) square, representing actual product, color and patterns.
F.
Manufacturer's Installation Instructions: Printed installation instructions for each signage system.
G.
Message Schedule: Signage report indicating signage location, text and sign type.
DELIVERY, STORAGE AND HANDLING A.
Deliver materials in unopened factory packaging.
B.
Inspect materials at delivery to verify there are no defects or damage.
C.
Store products in manufacturer's original packaging until ready for installation in climate controlled location away from direct sunlight.
D.
Store and dispose of solvent-based materials, and materials used with solvent-based
materials in accordance with requirements of local authorities having jurisdiction. 1.7
1.8
PROJECT CONDITIONS A.
Install products in an interior climate controlled environment.
B.
Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
WARRANTY A.
PART 2 2.1
At project closeout, provide to the Owner or Owner’s representative a copy of the manufacturer's standard limited warranty against manufacturing defect outlining the terms, conditions and exclusions from coverage. 1. Duration: One (1) year. PRODUCTS
MANUFACTURERS A.
Acceptable Manufacturer: Creative Sign Designs, 12801 Commodity Place, Tampa, FL 33626; Toll Free Tel: 800.804.4809; Tel: 813.818.7200; e-mail: info@creativesigndesigns.com; website: www.creativesigndesigns.com
B.
Substitutions: Not permitted unless bidder obtains approval from the Architect and/or Owner to bid alternates or substitutions to the specifications at least four weeks prior to bid date.
C.
Provide all signage from one manufacturer.
2.2 SIGNAGE – GENERAL ** NOTE TO SPECIFIER ** Remove products from the list below that are not required. The signage in this specification is manufactured using the photopolymer process. The specific photopolymer used in the manufacture of signage from CSD is manufactured by Nova Polymers and incorporates the use of the Novacryl product line. Novacryl is photopolymer integrally bonded to a Polyethylene Terephthalate Glycol (PETG) base. All materials must have a topcoat of acrylic polyurethane to ensure protection from cleaning agents, UV and moisture. Novacryl is fire rated for use in applications where fire hazard classification is required. A.
It is the intent of these specifications to establish a sign standard for the Owner including but not limited to primary and secondary directories, wall-mounted directional signs, primary room identification, restrooms, conference rooms, work station identification and all code compliant signage. While the Owner may not obtain all signs and sign types, the signage contractor shall design and submit approval drawings for all sign types relevant to the project.
B.
Comply with all applicable provisions of the ADAAG and ANSI A117.1 codes that apply to the State and Local jurisdiction of the project.
C.
If required text and graphics are not indicated in specification or on drawings, obtain Owner's instructions as to text and graphics prior to preparation of shop drawings.
D.
Typography: See Drawings. Copy shall be a clean and accurate reproduction of typeface(s) specified. Upper and lower case and all caps as indicated in Sign Type drawings and Signage Schedule. Letter spacing to be set by manufacturer.
E.
Arrows, symbols and pictograms will be provided in style, sizes, colors and spacing as indicated in drawings for each sign system. ** NOTE TO SPECIFIER ** Remove all but one of the following. F.
Braille 1. Grade 2 Braille 2. California Braille ** NOTE TO SPECIFIER ** Remove all but one of the following four placements. If more than one is required, indicate clearly where each will be applied. G.
Design 1. Text/Graphics Placement: Right justified. 2. Text/Graphics Placement: Centered. 3. Text/Graphics Placement: Left justified. 4. Text/Graphics Placement: As indicated on contract drawings. ** NOTE TO SPECIFIER ** Remove all but one of the following 4 font options. If more than one is required, indicate clearly where each will be applied. 5. Font: As Indicated on the Contract Drawings. 6. Font: Optima Medium. 7. Font: Frutiger. 8. Font: Helvetica Bold. 9. Font: Myriad Pro. 10. Font: ________________ 2.3
IDENTIFICATION SIGNAGE
A. System: Clarity: Studio 2. ** NOTE TO SPECIFIER ** All Clarity Studio 2 signs contain a colored backplate and an ADA plate with the exception of the F-P Flagmount Portrait and the LS-F Fire Extinguisher. Make one selection from sections B – H. If making more than one selection per section, please be specific. Remove what is not needed. B.
ADA Plate Color Selection 1. Red 101 2. Burgundy 102 3. TERRA COTTA 103 4. Yellow 104 5. Green 105 6. Pine 106 7. Forest Green 107 8. Island Blue 108 9. Blue 109 10. Royal Blue 110 11. Union Blue 111 12. Shadow Blue 112 13. Ivory 113 14. Sand 114 15. Beige 115 16. Ash 116 17. Off-White 117 18. Bright White 118 19. Birch Grey 119 20. Medium Grey 120 21. Dark Grey 121 22. Charcoal 122
23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. C.
Taupe 123 Stone 124 Mink 125 Dark Brown 126 Black 127 Gold 128 Silver 129 Graphite 130 LAM-Biltmore Cherry LAM-Brighton Walnut LAM-Cocobala LAM-Kensington Maple LAM-Monticello Maple ECO-Aqua ECO-Banana Fiber Lite ECO-Bear Grass Lite ECO-Bronze Weave ECO-Fossil Leaf Color: ________________
Backplate Color Selection 1. Red 101 2. Burgundy 102 3. TERRA COTTA 103 4. Yellow 104 5. Green 105 6. Pine 106 7. Forest Green 107 8. Island Blue 108 9. Blue 109 10. Royal Blue 110 11. Union Blue 111 12. Shadow Blue 112 13. Ivory 113 14. Sand 114 15. Beige 115 16. Ash 116 17. Off-White 117 18. Bright White 118 19. Birch Grey 119 20. Medium Grey 120 21. Dark Grey 121 22. Charcoal 122 23. Taupe 123 24. Stone 124 25. Mink 125 26. Dark Brown 126 27. Black 127 28. Gold 128 29. Silver 129 30. Graphite 130 31. LAM-Biltmore Cherry 32. LAM-Brighton Walnut 33. LAM-Cocobala 34. LAM-Kensington Maple 35. LAM-Monticello Maple
36. 37. 38. 39. 40. 41.
ECO-Aqua ECO-Banana Fiber Lite ECO-Bear Grass Lite ECO-Bronze Weave ECO-Fossil Leaf Color: ________________
D.
ADA Raised Copy Color Selection 1. Black 2. White 3. Gold 1255 4. Grey 430 5. Metallic silver 877 6. Tan 7501 7. Brown 7518 8. Color: _____________
E.
ADA Font Choices 1. Font: As Indicated on the Contract Drawings. 2. Font: Optima Medium. 3. Font: Frutger. 4. Font: Helvetica Bold. 5. Font: Myriad Pro. 6. Font: ________________
F.
ADA Plate Gauge Selection 1. 1/8” 2. 1/4” 3. Other: ________________
G.
Backplate Gauge Selection 1. 1/8” 2. 1/4” 3. Other: ________________
H.
Corner Finishes 1. Square 2. Round 3. Scallop 4. Bevel ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. Each line of copy has up to 14 characters per line (5/8” copy). I.
Sign Type – Standard Room ID 1. R.0 - Room ID - Small a. Size: 3.5” x 6.5” b. Qty: _________ 2.
R.1 - Room ID – 1 Line a. Size: 3.5” x 9.5” b. Qty: _________
3.
R.2 - Room ID – 2 Line a. Size: 4.5” x 9.5” b. Qty: _________
4.
R.3 - Room ID – 3 Line
a. b.
Size: 6.5” x 9.5” Qty: _________
5.
CR - Conference Room – 3 Line (In Use/Vacant Slider) a. Size: 8.5” x 9.5” b. Qty: _________
6.
RIN.0 - Room ID – Small Insert (Insert Size: 8.5”x3”) a. Size: 7.5” x 9.5” b. Qty: _________
7.
RIN.1 - Room ID – Large Insert (Insert Size: 8.5”x5.5”) a. Size: 9” x 9.5” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. The pictograms are 6”x6” with one line of copy. Each line of copy has up to 14 characters per line (5/8” copy). J.
Sign Type – Room ID (Code Required Signage) 1. RR-M - Men a. Size: 10” x 10” b. Qty: _________ 2.
RR-W - Women a. Size: 10” x 10” b. Qty: _________
3.
RR-U - Unisex a. Size: 10” x 10” b. Qty: _________
4.
RR-MA - Men / Accessible a. Size: 10” x 10” b. Qty: _________
5.
RR-WA - Women / Accessible a. Size: 10” x 10” b. Qty: _________
6.
RR-UA - Unisex / Accessible a. Size: 10” x 10” b. Qty: _________
7.
S - Stairwell a. Size: 10” x 10” b. Qty: _________
8.
P – Misc. Pictogram a. Size: 10” x 10” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. All artwork for E.2P and E.4P Evacuation Maps are to be provided by client or architect. Remove what is not needed. K. Sign Type – Life Safety Signage (Code Required Signage) 1. EXIT – Exit - Up to 10 Character with 5/8” Copy a. Size: 3.5” x 6.5”
b.
Qty: _________
2.
LS-MO Informational – Up to 14 Characters Per Line with 5/8” Copy a. Size: 6.5” x 9.5” b. Qty: _________
3.
LS-F Fire Extinguisher - Up to 14 Characters Per Line with 5/8” Copy a. Size: 5.5” x 8.5” b. Qty: _________
4.
LS-S - In Case of Fire - Up to 14 Characters Per Line with 5/8” Copy a. Size: 10” x 10” b. Qty: _________
5.
L - Level Indicator a. Size: 14” x 12” b. Qty: _________
6.
E.2P - Evacuation Map (Insert Size: 8.5”x11”) a. Size: 15.5” x 9.5” b. Qty: _________
7.
E.4P - Evacuation Map (Insert Size: 11”x17”) a. Size: 21.5” x 12” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. L.
Sign Type – Work Station and Miscellaneous Inserts 1. IN.0 – Extra Small Inserts (Insert Size 8.5”x3”) a. Size: 4” x 9.5” b. Qty: _________ 2.
IN.1L – Small Landscape Insert (Insert Size: 8.5”x5.5”) a. Size: 6.5” x 9.5” b. Qty: _________
3.
N.2L – Letter Landscape Inserts (Insert Size: 8.5”x11”) a. Size: 10.5” x 12” b. Qty: _________
4.
IN.3L – Legal Landscape Insert (Insert Size: 8.5”x14”) a. Size: 10.5” x 15” b. Qty: _________
5.
IN.4L – Tabloid Landscape Insert (Insert Size: 11”x17”) a. Size: 12” x 18” b. Qty: _________
6.
IN.1P - Small Portrait Insert (Insert Size: 8.5”x5.5”) a. Size: 10.5” x 6.5” b. Qty: _________
7.
IN.2P - Letter Portrait Insert (Insert Size: 8.5”x11”) a. Size: 13” x 9.5” b. Qty: _________
8.
IN.3P – Legal Portrait Insert (Insert Size: 8.5”x14”) a. Size: 16” x 9.5” b. Qty: _________
9.
IN.4P – Tabloid Portrait Insert (Insert Size: 11”x17”) a. Size: 19” x 12” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. M.
Sign Type – Wall Directionals 1. WD.2P-1 - Single Insert Directory - 1 Slot with 5/8” Copy (Insert Size: 8.5”x11”) a. Size: 15.5” x 9.5” b. Qty: _________ 2.
WD.2P-5 - Single Insert Directory – 5 Slots with 5/8” Copy (Insert Size: 8.5”x2”) a. Size: 15.5” x 9.5” b. Qty: _________
3.
WD.2P-9 - Single Insert Directory - 9 Slots with 5/8” Copy (Insert Size: 8.5”x1”) a. Size: 15.5” x 9.5” b. Qty: _________
4.
WD.4P-1 - Single Insert Directory - 1Slot with 1” Copy (Insert Size: 11”x17”) a. Size: 21.5” x 12” b. Qty: _________
5.
WD.4P-9 - Single Insert Directory - 9 Slots with 5/8” Copy (Insert Size: 11”x7.5”) a. Size: 21.5” x 12” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. N.
Sign Type – Flagmounts 1. F-L - Flagmount Landscape Double Sided a. Size: 6” x 17” b. Qty: _________ 2.
F-P - Flagmount Portrait Double Sided a. Size: 5” x 16” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. There must be 80” clearance from the floor to the bottom on the signs in this section. ADA requires at least 3” copy on directionals. O.
Sign Type – Overhead Directionals 1. OD.8-48 - Overhead Directory Standard - Double Sided with Up To 2 Lines of Copy a. Size: 8” x 48” b. Qty: _________ 2.
OD.12-48 - Overhead Directory Standard – Double Sided with up to 3 Lines
of Copy a. Size: 12” x 48” b. Qty: _________ 3.
OD.8-72 - Overhead Directory Large – Double Sided with up to 2 Lines of Copy a. Size: 8” x 72” b. Qty: _________
4.
OD.12-72 - Overhead Directory Large – Double Sided with up to 2 Lines of Copy a. Size: 12” x 72” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. P.
Sign Type – Directories 1. D.1 - Single Insert Directory – Single Insert with 1.25” Copy (Insert Size: 22’x30”) a. Size: 36” x 22” b. Qty: _________ 2.
D.12 - Multiple Insert Directory – 12 Slots with 1.25” Copy (Insert Size: 22”x2”) a. Size: 36” x 22” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required mounting method. Remove what is not needed. Q.
Mounting 1. Double face tape and silicone mount. 2. Mechanical, tamper resistant fasteners.
R.
EXECUTION 1. EXAMINATION a. Verify that wall surface is dry and free from dirt, grease and loose paint. b. Complete all finishing operations, including painting, before beginning installation of signage systems. c. Do not begin installation until substrates have been properly prepared. d. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. e. Examine signage for defects prior to installation. Do not install damaged signage. 2.
PREPARATION a. Verify mounting heights and locations comply with referenced standards. b. Clean surfaces thoroughly prior to installation to remove dust, debris and loose particles. c. Prepare surfaces using the methods recommended by the manufacturer for achieving the best results for the substrate under the project conditions.
3.
INSTALLATION
a. b. c.
Locate the signage system as indicated on drawings for the appropriate substrate and in accordance with manufacturer's installation instructions. Install signage systems level and plumb at the height indicated on the drawings. Mount in accordance with current ADA and state regulations.
4.
CLEANING a. At completion of installation, clean surfaces in accordance with manufacturer's instructions.
5.
PROTECTION a. Protect installed products until completion of project. b. Touch up, repair or replace damaged products before substantial completion. END OF SECTION
Creative Sign Designs
SECTION 10440 INTERIOR SIGNAGE Clarity Studio 3 Display hidden notes to specifier. (Don't know how? Click Here)
NOTE TO SPECIFIER ** Creative Sign Designs; Interior Signage. This section is based on the products manufactured Creative Sign Designs, which is located at: 12801 Commodity Place Tampa, FL 33626 Tel: (800) 804.4809 Tel: (813) 915.1900 Fax: (813) 818.7200 Email: info@creativesigndesigns.com Website: www.creativesigndesigns.com With a consultative approach to architectural signage, Creative Sign Designs specializes in guiding people in and around places. Whether it’s guiding you through the design of a project and the selection of materials or guiding the end user to, through and around the space, we are guiding every step of the way. As a custom sign fabricator, we believe a successful program involves more than just investing in first-rate products. It requires meticulous planning and execution for the end result to be functional, cost efficient and compliant with pertinent regulations, such as the Americans with Disabilities Act (ADA). With over a quarter century of experience in the sign industry, Creative Sign Designs has the know how to successfully complete projects for clients in any industry, anywhere. PART 1GENERAL 1.1 SECTION INCLUDES ** NOTE TO SPECIFIER ** Remove items below not required for project.
1.2
A.
Room Identification.
B.
Stairs.
C.
Restroom.
D.
Elevator Lobby.
E.
Informational Signage.
F.
Directory Signage.
RELATED SECTIONS
** NOTE TO SPECIFIER ** Remove any sections below not relevant to this project; add others as required.
1.3
1.4
A.
Section 10410 - Directories.
B.
Section 10420 - Plaques.
C.
Section 10430 - Exterior Signage.
REFERENCES A.
ANSI 117.1 – For Buildings and Facilities
B.
ASTM International (ASTM) D635 - Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.
C.
ASTM International (ASTM) E84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
D.
ASTM International (ASTM) D1929 - Standard Test Method for Determining Ignition Temperature of Plastics.
E.
Underwriters Laboratories (UL) 94 - Tests for Flammability of Plastic Materials for Parts in Devices and Appliances.
F.
Underwriters Laboratories (UL) 723 - Standard for Test for Surface Burning Characteristics of Building Materials.
G.
ASTM E2072-04 - Standard Specification for Photoluminescent (Phosphorescent) Safety Marketing.
H.
ASTM E2073-02 - Standard Test Method for Photopic Luminance of Photo Luminescent (Phosphorescent) Markings.
PERFORMANCE REQUIREMENTS A.
Provide photopolymer signage that conforms to the requirements of all regulatory agencies holding jurisdiction and the quality control of CSD. ** NOTE TO SPECIFIER ** Retain the next paragraph only if glow in the dark signage is specified. B.
Provide glow in the dark, photo luminescent material that complies with applicable provisions of ASTM E 2073-02 and DIN 67510. Photo luminescent material must have up to eight hours of luminance. ** NOTE TO SPECIFIER ** Remove the next paragraph if ADA conformance is not required. C.
Requirements: 1. Comply with all applicable provisions of the ADA and ANSI A117.1-1998. 2. Character Proportion: Letters and numbers on signs must have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10. 3. Color Contrast: Characters and symbols must contrast with their background - either light characters on a dark background or dark characters on a light background. 4. Raised Characters or Symbols: Letters and numbers on signs must be raised 1/32 in (0.8 mm) minimum and be sans serif characters. Raised characters or symbols must be at least 5/8 in (16 mm) high but no higher than 2 in (50
5. 6. D.
1.5
mm). Symbols or pictograms on signs must be raised 1/32 in (0.8 mm) minimum. Symbols of Accessibility: Accessible facilities required to be identified must use the international symbol of accessibility. Braille: Grade II with accompanying text.
Fire Performance Characteristics: 1. Provide photopolymer signage with surface burning characteristics that consist of a flame spread of 75 and a smoke development of 120 when tested in accordance to UL 723 (ASTM E 84). 2. Self-Extinguishing: Provide photopolymer signage with a CC1 classification for .060 in thick material when tested in accordance with the procedures in ASTM D 635, Standard Test Method for Rate of Burning and/or Extent and Time of Burning Plastics in a Horizontal Position. 3. Vertical Burn: Provide photopolymer material that is classified as 94V-2 for material .118 in thick or greater and 94HB for material .118 in thick or less when tested in accordance with UL 94, Tests for Flammability of Plastic Materials for Parts in Devices and Appliances. 4. Self-Ignition Temperature: Provide photopolymer material that has a o o self-ignition temperature of 800 F (427 C) when tested in accordance with ASTM D 1929.
SUBMITTALS A.
Submit under provisions of Section 01300.
B.
Product Data: Manufacturer's data sheets on each product to be used including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods.
C.
Shop Drawings: Detail drawings showing sizes, lettering and graphics, construction details of each type of sign and mounting details with appropriate fasteners for specific project substrates. ** NOTE TO SPECIFIER ** Remove selection samples if colors already have been selected.
1.6
D.
Selection Samples: For each finish product specified, two sets of color sheets representing manufacturer's full range of available colors and patterns.
E.
Verification Samples: For each sign type and color specified, two samples, minimum size 6 in (150 mm) square, representing actual product, color and patterns.
F.
Manufacturer's Installation Instructions: Printed installation instructions for each signage system.
G.
Message Schedule: Signage report indicating signage location, text and sign type.
DELIVERY, STORAGE AND HANDLING A.
Deliver materials in unopened factory packaging.
B.
Inspect materials at delivery to verify there are no defects or damage.
C.
Store products in manufacturer's original packaging until ready for installation in climate controlled location away from direct sunlight.
D.
Store and dispose of solvent-based materials, and materials used with solvent-based
materials in accordance with requirements of local authorities having jurisdiction. 1.7
1.8
PROJECT CONDITIONS A.
Install products in an interior climate controlled environment.
B.
Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
WARRANTY A.
PART 2 2.1
At project closeout, provide to the Owner or Owner’s representative a copy of the manufacturer's standard limited warranty against manufacturing defect outlining the terms, conditions and exclusions from coverage. 1. Duration: One (1) year. PRODUCTS
MANUFACTURERS A.
Acceptable Manufacturer: Creative Sign Designs, 12801 Commodity Place, Tampa, FL 33626; Toll Free Tel: 800.804.4809; Tel: 813.818.7200; e-mail: info@creativesigndesigns.com; website: www.creativesigndesigns.com
B.
Substitutions: Not permitted unless bidder obtains approval from the Architect and/or Owner to bid alternates or substitutions to the specifications at least four weeks prior to bid date.
C.
Provide all signage from one manufacturer.
2.2 SIGNAGE – GENERAL ** NOTE TO SPECIFIER ** Remove products from the list below that are not required. The signage in this specification is manufactured using the photopolymer process. The specific photopolymer used in the manufacture of signage from CSD is manufactured by Nova Polymers and incorporates the use of the Novacryl product line. Novacryl is photopolymer integrally bonded to a Polyethylene Terephthalate Glycol (PETG) base. All materials must have a topcoat of acrylic polyurethane to ensure protection from cleaning agents, UV and moisture. Novacryl is fire rated for use in applications where fire hazard classification is required. A.
It is the intent of these specifications to establish a sign standard for the Owner including but not limited to primary and secondary directories, wall-mounted directional signs, primary room identification, restrooms, conference rooms, work station identification and all code compliant signage. While the Owner may not obtain all signs and sign types, the signage contractor shall design and submit approval drawings for all sign types relevant to the project.
B.
Comply with all applicable provisions of the ADAAG and ANSI A117.1 codes that apply to the State and Local jurisdiction of the project.
C.
If required text and graphics are not indicated in specification or on drawings, obtain Owner's instructions as to text and graphics prior to preparation of shop drawings.
D.
Typography: See Drawings. Copy shall be a clean and accurate reproduction of typeface(s) specified. Upper and lower case and all caps as indicated in Sign Type drawings and Signage Schedule. Letter spacing to be set by manufacturer.
E.
Arrows, symbols and pictograms will be provided in style, sizes, colors and spacing as indicated in drawings for each sign system. ** NOTE TO SPECIFIER ** Remove all but one of the following. F.
Braille 1. Grade 2 Braille 2. California Braille ** NOTE TO SPECIFIER ** Remove all but one of the following four placements. If more than one is required, indicate clearly where each will be applied. G.
Design 1. Text/Graphics Placement: Right justified. 2. Text/Graphics Placement: Centered. 3. Text/Graphics Placement: Left justified. 4. Text/Graphics Placement: As indicated on contract drawings. ** NOTE TO SPECIFIER ** Remove all but one of the following 4 font options. If more than one is required, indicate clearly where each will be applied. 5. Font: As Indicated on the Contract Drawings. 6. Font: Optima Medium. 7. Font: Frutiger. 8. Font: Helvetica Bold. 9. Font: Myriad Pro. 10. Font: ________________ 2.3
IDENTIFICATION SIGNAGE
A. System: Clarity: Studio 3. ** NOTE TO SPECIFIER ** All Clarity Studio 3 signs contain a colored backplate and an ADA plate with the exception of the F-P Flagmount Portrait and the LS-F Fire Extinguisher. Make one selection from sections B – H. If making more than one selection per section, please be specific. Remove what is not needed. B.
ADA Plate Color Selection 1. Red 101 2. Burgundy 102 3. TERRA COTTA 103 4. Yellow 104 5. Green 105 6. Pine 106 7. Forest Green 107 8. Island Blue 108 9. Blue 109 10. Royal Blue 110 11. Union Blue 111 12. Shadow Blue 112 13. Ivory 113 14. Sand 114 15. Beige 115 16. Ash 116 17. Off-White 117 18. Bright White 118 19. Birch Grey 119 20. Medium Grey 120 21. Dark Grey 121 22. Charcoal 122
23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. C.
Taupe 123 Stone 124 Mink 125 Dark Brown 126 Black 127 Gold 128 Silver 129 Graphite 130 LAM-Biltmore Cherry LAM-Brighton Walnut LAM-Cocobala LAM-Kensington Maple LAM-Monticello Maple ECO-Aqua ECO-Banana Fiber Lite ECO-Bear Grass Lite ECO-Bronze Weave ECO-Fossil Leaf Color: ________________
Backplate Color Selection 1. Red 101 2. Burgundy 102 3. TERRA COTTA 103 4. Yellow 104 5. Green 105 6. Pine 106 7. Forest Green 107 8. Island Blue 108 9. Blue 109 10. Royal Blue 110 11. Union Blue 111 12. Shadow Blue 112 13. Ivory 113 14. Sand 114 15. Beige 115 16. Ash 116 17. Off-White 117 18. Bright White 118 19. Birch Grey 119 20. Medium Grey 120 21. Dark Grey 121 22. Charcoal 122 23. Taupe 123 24. Stone 124 25. Mink 125 26. Dark Brown 126 27. Black 127 28. Gold 128 29. Silver 129 30. Graphite 130 31. LAM-Biltmore Cherry 32. LAM-Brighton Walnut 33. LAM-Cocobala 34. LAM-Kensington Maple 35. LAM-Monticello Maple
36. 37. 38. 39. 40. 41.
ECO-Aqua ECO-Banana Fiber Lite ECO-Bear Grass Lite ECO-Bronze Weave ECO-Fossil Leaf Color: ________________
D.
ADA Raised Copy Color Selection 1. Black 2. White 3. Gold 1255 4. Grey 430 5. Metallic silver 877 6. Tan 7501 7. Brown 7518 8. Color: _____________
E.
ADA Font Choices 1. Font: As Indicated on the Contract Drawings. 2. Font: Optima Medium. 3. Font: Frutger. 4. Font: Helvetica Bold. 5. Font: Myriad Pro. 6. Font: ________________
F.
ADA Plate Gauge Selection 1. 1/8” 2. 1/4” 3. Other: ________________
G.
Backplate Gauge Selection 1. 1/8” 2. 1/4” 3. Other: ________________
H.
Corner Finishes 1. Square 2. Round 3. Scallop 4. Bevel ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. Each line of copy in this section has up to 14 characters per line (5/8” copy) with the exception of R.0, which allows up to 10 characters with 5/8” copy. I.
Sign Type – Standard Room ID 1. R.0 - Room ID – Small (Diamond Shaped) a. Size: 6” x 6” b. Qty: _________ 2.
R.1 - Room ID – 1 Line (Diamond Shaped) a. Size: 7.5” x 7.5” b. Qty: _________
3.
R.2 - Room ID – 2 Line (Diamond Shaped) a. Size: 7.5” x 7.5” b. Qty: _________
4.
R.3 - Room ID – 3 Line (Diamond Shaped) a. Size: 7.5” x 7.5” b. Qty: _________
5.
CR - Conference Room – 3 Line (Diamond Shaped with Vertical In Use/Vacant Slider) a. Size: 10.59” x 9.5” b. Qty: _________
6.
RIN.0 - Room ID – Small Insert (Diamond Shaped Top Tactile Piece with Insert - Size: 8.5”x3”) a. Size: 7.5” x 9.5” b. Qty: _________
7.
RIN.1 - Room ID – Large Insert (Diamond Shaped Top Tactile Piece with Insert - Size: 8.5”x5.5”) a. Size: 9” x 9.5” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. Note the pictograms are 6”x6” with one line of copy. Each line of copy in this section has up to 14 characters per line (5/8” copy). J.
Sign Type – Room ID (Code Required Signage) 1. RR-M - Men (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________ 2.
RR-W – Women (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
3.
RR-U – Unisex (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
4.
RR-MA - Men / Accessible (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
5.
RR-WA - Women / Accessible (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
6.
RR-UA - Unisex / Accessible (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
7.
S – Stairwell (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
8.
P – Misc. Pictogram (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. All artwork for E.2P and E.4P Evacuation Maps are to be provided by client or architect. Remove what is not needed.
K. Sign Type – Life Safety Signage (Code Required Signage) 1. EXIT – Exit - Up to 10 Character with 5/8” Copy (Diamond Shaped) a. Size: 6” x 6.” b. Qty: _________ 2.
LS-MO - Informational – Up to 14 Characters Per Line with 5/8” Copy (Diamond Shaped) a. Size: 8.5” x 8.5” b. Qty: _________
3.
LS-F - Fire Extinguisher - Up to 14 Characters Per Line with 5/8” Copy (Diamond Shaped) a. Size: 8.5” x 8.5” b. Qty: _________
4.
LS-S - In Case of Fire - Up to 14 Characters Per Line with 5/8” Copy (Diamond Shaped) a. Size: 10” x 10” b. Qty: _________
5.
L - Level Indicator a. Size: 15” x 13” b. Qty: _________
6.
E.2P - Evacuation Map (Insert Size: 8.5”x11”) a. Size: 15.5” x 9.5” b. Qty: _________
7.
E.4P - Evacuation Map (Insert Size: 11”x17”) a. Size: 21.5” x 12” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. L.
Sign Type – Work Station and Miscellaneous Inserts 1. IN.0 – Extra Small Inserts (Insert Size 8.5”x3”) a. Size: 4” x 9.5” b. Qty: _________ 2.
IN.1L – Small Landscape Insert (Insert Size: 8.5”x5.5”) a. Size: 6.5” x 9.5” b. Qty: _________
3.
N.2L – Letter Landscape Inserts (Insert Size: 8.5”x11”) a. Size: 10.5” x 12” b. Qty: _________
4.
IN.3L – Legal Landscape Insert (Insert Size: 8.5”x14”) a. Size: 10.5” x 15” b. Qty: _________
5.
IN.4L – Tabloid Landscape Insert (Insert Size: 11”x17”) a. Size: 12” x 18” b. Qty: _________
6.
IN.1P - Small Portrait Insert (Insert Size: 8.5”x5.5”) a. Size: 10.5” x 6.5”
b.
Qty: _________
7.
IN.2P - Letter Portrait Insert (Insert Size: 8.5”x11”) a. Size: 13” x 9.5” b. Qty: _________
8.
IN.3P – Legal Portrait Insert (Insert Size: 8.5”x14”) a. Size: 16” x 9.5” b. Qty: _________
9.
IN.4P – Tabloid Portrait Insert (Insert Size: 11”x17”) a. Size: 19” x 12” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. M.
Sign Type – Wall Directionals 1. WD.2P-1 - Single Insert Directory - 1 Slot with 5/8” Copy (Insert Size: 8.5”x11”) a. Size: 15.5” x 9.5” b. Qty: _________ 2.
WD.2P-5 - Single Insert Directory – 5 Slots with 5/8” Copy (Insert Size: 8.5”x2”) a. Size: 15.5” x 9.5” b. Qty: _________
3.
WD.2P-9 - Single Insert Directory - 9 Slots with 5/8” Copy (Insert Size: 8.5”x1”) a. Size: 15.5” x 9.5” b. Qty: _________
4.
WD.4P-1 - Single Insert Directory - 1Slot with 1” Copy (Insert Size: 11”x17”) a. Size: 21.5” x 12” b. Qty: _________
5.
WD.4P-9 - Single Insert Directory - 9 Slots with 5/8” Copy (Insert Size: 11”x7.5”) a. Size: 21.5” x 12” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. N.
Sign Type – Flagmounts 1. F-L - Flagmount Landscape Double Sided a. Size: 6” x 17” b. Qty: _________ 2.
F-P - Flagmount Portrait Double Sided a. Size: 5” x 16” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. There must be 80” clearance from the floor to the bottom on the signs in this section. ADA requires at least 3” copy on directionals. O.
Sign Type – Overhead Directionals 1. OD.8-48 - Overhead Directory Standard - Double Sided with Up To 2 Lines
of Copy a. Size: 8” x 48” b. Qty: _________ 2.
OD.12-48 - Overhead Directory Standard – Double Sided with up to 3 Lines of Copy a. Size: 12” x 48” b. Qty: _________
3.
OD.8-72 - Overhead Directory Large – Double Sided with up to 2 Lines of Copy a. Size: 8” x 72” b. Qty: _________
4.
OD.12-72 - Overhead Directory Large – Double Sided with up to 2 Lines of Copy a. Size: 12” x 72” b. Qty: _________ ** NOTE TO SPECIFIER ** Select the required sizes and quantities in this section. Remove what is not needed. P.
Sign Type – Directories 1. D.1 - Single Insert Directory – Single Insert with 1.25” Copy (Insert Size: 22’x30”) a. Size: 36” x 22” b. Qty: _________ 2.
D.12 - Multiple Insert Directory – 12 Slots with 1.25” Copy (Insert Size: 22”x2”) a. Size: 36” x 22” b. Qty: _________
Q.
Mounting 1. Brushed silver stand-off hardware.
R.
EXECUTION 1. EXAMINATION a. Verify that wall surface is dry and free from dirt, grease and loose paint. b. Complete all finishing operations, including painting, before beginning installation of signage systems. c. Do not begin installation until substrates have been properly prepared. d. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. e. Examine signage for defects prior to installation. Do not install damaged signage. 2.
PREPARATION a. Verify mounting heights and locations comply with referenced standards. b. Clean surfaces thoroughly prior to installation to remove dust, debris and loose particles. c. Prepare surfaces using the methods recommended by the manufacturer for achieving the best results for the substrate under the project conditions.
3.
INSTALLATION a. Locate the signage system as indicated on drawings for the appropriate substrate and in accordance with manufacturer's installation instructions. b. Install signage systems level and plumb at the height indicated on the drawings. c. Mount in accordance with current ADA and state regulations.
4.
CLEANING a. At completion of installation, clean surfaces in accordance with manufacturer's instructions.
5.
PROTECTION a. Protect installed products until completion of project. b. Touch up, repair or replace damaged products before substantial completion. END OF SECTION
ADA SIGNAGE REGULATIONS
a rm ms oo l/Info R t na en ad an ectio he r m e r Dir Pe Ov
C HA RAC TER P R O P O R T I O N ( ADA 4 . 3 0. 2) Characters must have a width-to-height ratio between 3:5 and 1:1
s
s
s
Characters must have a stroke-to-height ratio between 1:5 and 1:10
s
s
s
C HA RAC TER H E I G H T ( A DA 4 . 3 0. 3) Characters must be sized according to the viewing distance
s
Characters must be 3” minimum in height
s
Characters shall be at least 5/8” in height, but no higher than 2”
s
RA I S ED & BR AI LLE CH AR AC T E R S A ND PIC TO GR A M S I GN S (A DA 4.30.4) Tactile characters and Grade 2 Braille must be raised 1/32”
s
Tactile characters must be accompanied with Grade 2 Braille
s
Characters must be upper case, sans serif
s
Characters must be a minimum of 5/8” high, maximum of 2” high
s
Equivalent verbal descriptions must be placed directly below the pictogram
s
Pictogram can be any size within a minimum field of 6” in height
s
FI N I S H A ND CO N T R AS T ( A DA 4. 30 . 5 ) Characters and background must have an eggshell, matte, or non-glare finish
s
s
s
Characters must contrast with the background (recommended 70%)
s
s
s
MOUN TI N G L O CAT I O N A N D H EI GH T (ADA 4 . 3 0. 6) Mount on the wall adjacent to the latch side of the door
s
Where there is no wall space, mount on the nearest adjacent wall
s
Mounting height of 60” from the floor to the center line of the sign
s
Mounting location clear of protruding objects or door swing
s
Minimum 80” clearance between overhead sign and floor (ADA 4.4.2)
SU G G ES TE D VI EWI N G D I S TAN C E CHAR T Letter Size:
Distance Viewed From:
5/8”
13 ft.
1”
20 ft.
3”
120 ft.
s s
There must be a minimum 6" x 6" area for the pictogram with no text in the area. A verbal description must go directly below the pictogram.
This information is presented as an informational summary only. We cannot assume liability for errors, omissions, or any damages resulting from the use of interpretation of this material. For more information about the Americans with Disabilities Act, contact the US Department of Justice or visit ada.gov.
Visit us at www.CreativeSignDesigns.com, call 800.804.4809 or email Sales@CreativeSignDesigns.com to learn more. 100% RECYCLED
n
tio
ADA TYPESIZING REQUIREMENTS The new ADAAG is significantly more stringent in the area of typography for the blind. Reading tactile letters is extremely difficult. The letters must be relatively consistent in size and shape on every sign in the environment in order to be easily read. Tactile letters must also be smaller in size and simpler than most visual letters in the environment. Tactile type, though, applies only to permanent room identification signs; these apply to rooms that will not change names for at least a year.
HEIGHT OF TACTILE LETTERS There is only a narrow band of allowable heights for tactile letters: 5/8” minimum and 2” maximum based on the letter “I” (703.2.5); minimum letters are allowed on dual signs. Tactile letters must always be capitalized. Tactile letters must also be a minimum 1/32” in height from the surface of the sign. They may be beveled or chamfered.
CHARACTER PROPORTION AND STROKE WIDTH Tactile letters must be sans serif and always capitalized. Characters must be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I” at the top of the tactile text (703.5.4). The stroke width may be only 15% maximum of the height of the letter “I” (703.5.6). Two fonts that traditionally work well under these guidelines are Futura Regular and Optima Medium. Under the new ADAAG, very few fonts are allowed (some of the commonly used typefaces that are NOT allowed include Times Roman, Optima, and most bold fonts, including Helvetica Medium and Futura Bold), so you should test each font’s stroke width to be sure. Stroke width rules are only for the top of tactile letters. If bold characters are beveled, they may comply.
LETTER SPACING Character spacing is measured between the two closest points of adjacent tactile characters within a message, excluding word spaces. For unbeveled letters, there must be a 1/8” minimum spacing between letters and a maximum spacing of 4 times the letter stroke width. When characters are beveled, there must be a 1/16” spacing minimum at the letter base and 4 times the stroke width maximum at the base (703.2.7). Spacing requirements for the top of the letters are the same as for unbeveled letters. Characters must be separated from raised borders and decorative elements by 3/8” minimum.
This information is presented as an informational summary only. We cannot assume liability for errors, omissions, or any damages resulting from the use of interpretation of this material. For more information about the Americans with Disabilities Act, contact the US Department of Justice or visit ada.gov.
Visit us at www.CreativeSignDesigns.com, call 800.804.4809 or email Sales@CreativeSignDesigns.com to learn more. 100% RECYCLED
LETTER VISIBILITY CHARTS READING DISTANCE LETTER HEIGHT
R E A DA BLE DISTANCE F O R M A XI M U M I M PAC T
M A XI M U M REA DABLE DI S TA NC E
3 inches
30 feet
100 feet
4 inches
40 feet
150 feet
6 inches
60 feet
200 feet
8 inches
80 feet
350 feet
9 inches
90 feet
400 feet
10 inches
100 feet
450 feet
12 inches
120 feet
525 feet
15 inches
150 feet
630 feet
18 inches
180 feet
750 feet
24 inches
240 feet
1000 feet
30 inches
300 feet
1250 feet
36 inches
360 feet
1500 feet
42 inches
420 feet
1750 feet
48 inches
480 feet
2000 feet
54 inches
540 feet
2250 feet
60 inches
600 feet
2500 feet
NOTE: The distances will vary approximately 10% with different color variations. Maximum distance is in color with RED or BLACK on a white background. 5,280 feet equals one (1) mile.
READING TIME
(Length of time letters are readable when moving)
LETTER HEIGHT
3 0 M PH
4 0 M PH
6 0 M PH
80 MP H
6 inches
1.4 seconds
1.0 seconds
0.7 seconds
0.5 seconds
8 inches
1.8 seconds
1.4 seconds
0.9 seconds
0.7 seconds
12 inches
3.0 seconds
2.0 seconds
1.5 seconds
1.0 seconds
18 inches
4.0 seconds
3.0 seconds
2.0 seconds
1.5 seconds
24 inches
5.5 seconds
4.0 seconds
2.75 seconds
2.0 seconds
36 inches
8.0 seconds
6.0 seconds
4.0 seconds
3.0 seconds
Prepared by the California Institute of Technology. This information is presented as an informational summary only. We cannot assume liability for errors, omissions, or any damages resulting from the use of interpretation of this material.
Visit us at www.CreativeSignDesigns.com, call 800.804.4809 or email Sales@CreativeSignDesigns.com to learn more. 100% RECYCLED
ot ough om
3"
60"
ADA MOUNTING REQUIREMENTS
cu
3"
not enough room
60"
Typical Mounting Location
3"
ADA signs are typically wall mounted on the door handle side, 3� off door jamb, 60� above floor level (AFL) to the center-point of the sign. In certain situations (for example, in elementary schools), height AFL may, at owners choice, be changed to 48�. Signs mounted on doors are not ADA acceptable.
60"
3
3" not enough room
not enough room
not enough room
obstruction in typical mounting location
3"
3"
not enough room
3"
not enough room
60"
not enough room
3"
60"
60" Mounting Location Exceptions to the Typical
60"
60"
s )F THERE IS NOT ENOUGH ROOM MOUNT ON CLOSEST ADJACENT WALL v CLEAR OF OBSTRUCTIONS PROTRUDING OBJECTS OR SWING OF DOUBLE DOORS s )F GLASS PANELS ARE NEXT TO THE DOOR THE CUSTOMER SHOULD ADVISE IF THE SIGNS WILL BE INSTALLED ON GLASS MAY DICTATE AN ADDITIONAL back-up panel) or adjacent wall. s )N CIRCUMSTANCES WHEN NONE OF THE OPTIONS ABOVE APPLY USE YOUR BEST JUDGEMENT
customer choice
3"
3" not enough customer choice
3"
3"
room
3"
3"
not enough room
not enough room
60" 60"
60"
3"
not enough room
60"
60"
60"
customer choice
3" not enough room
3"
not enough room
60"
3"
not enough room
3"
60"
60"
60" swing of double door
if glass mount, back-up plate is required
60"
if glass mount, back-up plate
if glass mount, back-up plate is required
obstruction in typical mounting location obstruction in typical mounting location
not enough room
3"
3"
customer choice
3"
3"
swing of double door
60"
60"
obstruction in typical mounting location
3" 60"
60"
customer choice
3"
3"
60"
60" swing of double door
60"
3"
swin double
3" 60"
if glass mount, back-up plate is required
60" This information is presented as an informational summary only.if We cannot liability for errors, omissions, or any damages resulting from the use of interpretation of this back-up plate is required glass mount, assume material. For more information about the Americans with Disabilities Act, contact the US Department of Justice or visit ada.gov.
Visit us at www.CreativeSignDesigns.com, call 800.804.4809 or email Sales@CreativeSignDesigns.com to learn more. obstruction in typical mounting location
100% RECYCLED
ADA SUMMARY The Americans with Disabilities Act (ADA) mandates sign position, finish and contrast, typestyles, character height, and Braille requirements. All facilities, both public and private, with ten or more employees are affected.
FINISH AND CONTRAST Characters and background must be eggshell, matte or other non-glare finish. There also must be adequate contrast between background and copy colors. ADA requires a minimum of 70% contrast between copy and background.
TYPESTYLES AND CHARACTER HEIGHT Characters must utilize a sans serif typestyle. For permanent room signs, tactile characters must be upper case and a minimum of 5/8” and no more than 2” in height. They must have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:15 and 1:10. Overhead and flag mounts have a minimum character size of 3”. Upper and lower case are permissible. For directional signage, character height must be appropriate for the viewing distance. Again, upper and lower case characters may be utilized.
TACTILE CHARACTERS AND BRAILLE For permanent room signs, characters must be raised a minimum of 1/32” (0.8 mm) and accompanied with grade II Braille. Braille shall be domed in shape. Flat, square cornered Braille shall be avoided. Raised copy and Braille are not required on overhead or directional signage and minimum height is measured using an upper case “X.” Lower case characters are permitted.
PICTOGRAMS Pictograms must have a background field of at least 6” minimum in height. Pictograms shall be accompanied by the equivalent verbal description placed directly below the symbol and not within the field.
SIGN POSITION s Room with a single door – the tactile room identification sign shall be on the latch side s Double doors with one active leaf – the tactile room identification sign shall be on the inactive leaf s Double doors with two active leafs – the tactile room identification sign shall be to the right of the right hand door s )F A LACK OF WALL SPACE PRECLUDES ANY OF THE PRESCRIBED LOCATIONS THE TACTILE ROOM IDENTIlCATION SIGN MAY BE LOCATED AT THE NEAREST adjacent wall.
MOUNTING HEIGHT s Room Identification – Signs shall be located at 60” from floor to centerline of sign. s Overhead Signage – Signs shall have an 80”clearance from floor to bottom of sign. s Flag Mounted Signage – Signs shall have an 80” clearance from floor to bottom of sign if the projection from the wall is 4” or greater s Directories – Signs shall be mounted a minimum of 27” from floor with no more than 80” at the top.
This information is presented as an informational summary only. We cannot assume liability for errors, omissions, or any damages resulting from the use of interpretation of this material.
Visit us at www.CreativeSignDesigns.com, call 800.804.4809 or email Sales@CreativeSignDesigns.com to learn more. 100% RECYCLED