Track and Curtain Specification by On The Right Track

Page 1

(Section 102123)

www.OnTheRightTrack.com

TRACK & CURTAIN SPEC


Â

All On The Right Track (OTRT) cubicle curtains and track systems are designed to reduce Hospital-Acquired Infections (HAI) such as C Diff, MRSA and VRE. These dangerous and potentially deadly infections have become a threat to patients in hospitals everywhere. HAI’s are transferred by hand to cubicle curtains that are in direct contact with most patients. The solution is to wash the curtain more frequently. OTRT provides a modular panel system with a unique, engineered snap design that enables soiled curtains to be removed and replaced in seconds.

www.OnTheRightTrack.com


Universal Curtain Height

Retrofit

The Grabber

CONTENTS Curtains & Tracks Specifications Track Drawings Installation Guide Blocking for State of FL

www.OnTheRightTrack.com

…… 4 …... 8 ...… 10 ...… 28


SECTION 10 21 23 CUBICLE CURTAINS AND TRACKS Display hidden notes to specifier. (Don't know how? Click Here)

NOTE TO SPECIFIER ** On The Right Track; Cubicle Curtains and Tracks. This section is based on the products manufactured On The Right Track Systems Inc. which is located at: 174 Hudson Street, 4th Floor New York, NY 10013 Tel: (212) 625.6630 Tel: (804) 726-6999 Fax: (804) 726-6998 Email: moreinfo@ontherighttrack.com Website: http://www.ontherighttrack.com On The Right Track (OTRT) is the manufacturer of a cubicle curtains and track systems that are designed to reduce Hospital-Acquired Infections (HAI) such as C Diff, MRSA and VRE. These dangerous and potentially deadly infections have become a threat to patients in hospitals everywhere. HAI’s are transferred by hand to cubicle curtains that are in direct contact with most patients. The solution is to wash and /or change the curtain more frequently. The OTRT cubical curtain track system uses a patented split ring header system and comes in 69” standard panels and other custom sizes. It is convenient to hang and remove, making frequent curtain replacement easy, and putting infection control in your control. Other features include snap panels for efficient change out, a Grabber Tool for easier reaching, a mesh top for fire safety, a whisper quiet operation for patient satisfaction and a wide selection of fabrics for matching décor. PART 1 - GENERAL 1.01 SUMMARY ** NOTE TO SPECIFIER ** Remove items below not required for project. A.

Provide cubicle curtains and tracks for the following applications. 1. Hospital bed cubicles. 2. Examination areas. 3. Emergency areas. 4. Dressing areas.

www.OnTheRightTrack.com


** NOTE TO SPECIFIER ** Cubical curtains are often used for shower curtains. If this is not the intent, make sure to clarify shower curtain by naming either Hookless™ or OTRT shower curtains. B. Provide shower curtains at tubs and showers. C.

1.02

Related Work: 1. Section 09 21 16 - Gypsum Board Assemblies, for wallboard ceilings. 2. Section 09 51 00 - Acoustical Ceilings, for acoustical ceiling panels. SUBMITTALS

A.

Product Data: instructions.

B.

Verification Samples: and color.

C.

Shop Drawings: and tracks.

1.03

Submit manufacturer's product data, installation and maintenance Submit representative of curtain fabric specified to verify style

Submit reflected ceiling plans indicating locations of cubicle curtain

QUALITY ASSURANCE

A.

Flammability: Curtains shall pass NFPA 701 - Standard Methods of Fire Tests for Flame Propagation of Textiles and Films.

B.

Mock-Ups: Install one complete unit for approval prior to installation of remaining cubicle curtains and tracks. Approved mock-ups may remain in place.

1.04 A.

DELIVERY, STORAGE, AND HANDLING Deliver materials and products in unopened factory labeled packages. Store and handle in strict compliance with manufacturer's instructions and recommendations.

PART 2 - PRODUCTS 2.01

MANUFACTURER

A.

Acceptable Manufacturer: On the Right Track Systems, Inc., 174 Hudson Street, New York, NY 10013, Tel. 212-625-6630, www.ontherighttrack.com.

B.

Substitutions: Not permitted unless bidder obtains approval from the Architect and/or Owner to bid alternates or substitutions to the specifications at least four weeks prior to bid date.

2.02 CUBICAL CURTAINS AND TRACK SYSTEM ** NOTE TO SPECIFIER ** The following section outlines cubical curtains and track systems made by On The Right Track (OTRT). Section C describes shower curtains that can be used as shower curtains or cubical curtains. While OTRT offers a variety of curtains, any fabric can be custom fabricated with the track system. Make one selection from the following sections. If making more than one selection per section, please be specific. Remove what is not needed. A.

Cubicle Curtain Track: Provide a cubicle track system by On the Right Track Systems, Inc. with the following characteristics:

www.OnTheRightTrack.com


1. Surface Mounted Track: Extruded aluminum. ** NOTE TO SPECIFIER ** The Brushed Stainless and Oil Rubber Bronzes Finishes are considered custom options and require a minimum order quantity of 3,000 ft. Contact OTRT for more information. a. Powder Coated White Finish. b. Brushed Stainless Finish. c. Oil Rubbed Bronze Finish. d. Custom: ___________ 2. Dimensions: 1 1/2 inches (39 mm) high by 3/8 inch (10 mm) wide. ** NOTE TO SPECIFIER ** Straight sections are available in the following lengths: 3 feet (914 mm), 4 feet (1219 mm), 5 feet (1524 mm), and 8 feet (2438 mm). Bent sections are 1 and 2-foot (305 and 610 mm) radiused, and angled at 90 degrees or 135 degrees. 3. Provide straight and bent sections as indicated on drawings. 4. Accessories: Provide the following components. Coordinate locations with those found on the Contract Drawings. ** NOTE TO SPECIFIER ** Retain only accessories required on the project and delete all others. a. CE-OPTS-S02, Swivel Clip with Drop Ceiling Grid Mounting Plate. b. CE-OPTS-C02, End Wall Plate. c. CE-OPTS-E02, Hanger and Track Connector. d. CE-OPTS-F02, Track Connector. e. CE-OPTS-B02, Hard Ceiling Mounting Plate. f. CE-OPTS-M02, End Cap. g. CE-OPTS-G02, Hanger. h. CE-OPTS-P02, Ceiling Vertical Mount Plate. i. CE-OPTS-DO2, Hanger and Tube Connector. j. CE-OPTS-J02, Extensible Square Tube. k. CE-OPTS-001, Grabber (curtain loading tool). ** NOTE TO SPECIFIER ** Any curtain can be used with OTRT Cubical Curtain Track. If you are specifying another curtain or fabric from another manufacturer, specify the fabric manufacturer, pattern, style, repeat and size. Make one selection from the following sections. If making more than one selection per section, please be specific. Remove what is not needed. B. Cubical Curtains: Manufacturer’s inherently fire-retardant (IFR) curtain with panel, mesh and top designed for attachment to track without separate hooks. 1. Panel Size: 69 inches wide by 92 inches high including 19 inches of mesh, hemmed as required. 2. Style: a. Mini-Squares with Mesh IFR. 1) Color: Beige. 2) Color: Blue. 3) Color: Sage. 4) Color: Rose. b. Botanical Vines with Mesh IFR. c. Botanical Leaves with Mesh IFR. d. Custom Style: _____________ 4. Curtain Loading Tool: Manufacturer’s standard loading tool, The Grabber. 5. Curtain Ring a. Cream. b. Custom Color: __________ C.

Shower Curtains: Provide Hookless® Shower Curtains distributed by On the Right Track Systems, Inc.:

www.OnTheRightTrack.com


** NOTE TO SPECIFIER ** Select the size, style and color required. Remove what is not needed. 1. Panel Size: a. 71” x 74” b. 42” x 74” 2. Style: a. Pindot Vinyl. 1) Color: Beige. 2) Color: White. 3) Custom Color: __________ b. Vision Vinyl 1) Color: Beige. 2) Custom Color: __________ c. The Major Reversed Ring 1) Color: Beige. 2) Custom Color: __________ d. Litchfield Fabric 1) Color: White. 2) Color: Beige. 3) Custom Color: __________ e. Mini-Square FR 1) Color: Beige. 2) Color: Blue. 3) Color: Sage. 4) Custom Color: __________ 3. Curtain Loading Tool: Manufacturer’s standard loading tool, The Grabber. 4. Curtain Ring: Mystery Chrome Rings a. Beige. b. Blue. c. Sage. d. Rose. e. White. f. Lilac. g. Custom Color: __________ PART 3 - EXECUTION 3.01

INSTALLATION

A.

Installation of Cubicle Curtains and Tracks: Install in accordance with manufacturer’s recommendations, including the following: 1. Verify that ceilings are suitable for installation prior to installation. 2. Mechanically attach tracks using manufacturer’s recommended anchors and attachment devices. 3. Install accessories and curtains and test for proper operation. Replace damaged units.

B.

Installation of Shower Curtains: Install in accordance with manufacturer’s recommendations, on shower rod provided by others. END OF SECTION

www.OnTheRightTrack.com




Installation Guide


Installation Introduction The On The Right Track system is a very versatile system, it can being installed several different ways and on various ceiling types. Here are the installation types that you might encounter and the respective install instructions for each:

See all of the Parts -

Page 1-5

15/16th Grid acoustical Ceiling -

Page 6-7

9/16th Grid acoustical Ceiling -

Page 8

Gypsum board (drywall/hard Ceiling) -

Page 9

Attaching the Hangers -

Page 10

Wall mounts -

Page 11

Connection Track -

Page 12

Track End Connections -

Page 13

Using Extensible Tubing -

Page 14

Retro Fit Installing in the Existing rail

Page 15

Track Detail -

Page 16


Chapter 1: parts glossary Part # OPTS-S02 Swivel Clip with Drop Ceiling Grid Mounting Plate

Part # OPTS-C02 End Wall Plate

Part # OPTS-E02 Hanger & Track Connector

Part # OPTS-Q02 Room Divider Wall Mount


Chapter 1: parts glossary Part # OPTS-F02 Track Connector

Part # OPTS-B02 Hard Ceiling Mounting Plate

Part # OPTS-M02 End Cap

Part # OPTS-G02 Hanger


Chapter 1: parts glossary

Part # OPTS-P02 Ceiling Vertical Mount Plate

Part # OPTS-D02 Swivel Wall Plate

Part # OPTS-D02 Hanger & Tube Connector

Part # O-Spacers


Chapter 1: parts glossary Part # set screw OPTS-S102 5/32”x8mm

Part # Curtain Stopper OPTS UO2

Part # set screw OPTS-S602 5/32”x13mm

Part # OPTS-S302 5/32”x13mm self tap screw

Part # OPTS-S402 5/32”x1-1/4” mount screw

Part # OPTS-S802 Plastic Anchor

Part # OPTS-S902-1 (5/32 x 1” 5/32”x ¾”self tap screw

Part # OPTS-J02 Extensible Square Tube


Chapter 1: parts glossary cont. Part # OPTS-H802 180°8 Ft Track

Curved Track part numbers*

Part # OPTS-H502 180°5 Ft Track

Part # OPTS-K102 90°1 Ft Radius Track Part # OPTS-H402 180°4 Ft Track

Part # OPTS-H302 180°3 Ft Track

Part # OPTS-K1R02 90°Reversed 1 Ft Radius Track Part # OPTS-K202 90°2 Ft Radius Track Part # OPTS-K2R02 90°Reversed 2 Ft Radius Track Part # OPTS-L102 135°1 Ft Radius Track Part # OPTS-L1R02 135°Reversed 1 Ft Radius Track Part # OPTS-L202 135°2 Ft Radius Track Part # OPTS-L2R02 135°Reversed 2 Ft Radius Track *Contingent on Installation needs


Special Installation Instructions 15/16th Drop Ceiling Grid Mount The “Drop Ceiling Grid Mount” is a two piece mount. The center of the mount can be positioned and locked in place prior to attaching to drop ceiling grid work.

The center of the mount can be placed in one of 8 positions to accommodate installment needs.

Swivel Clips should be secured 24” apart.

This also allows the grabber enough space to remove and replace curtains. Please remember that if the track is secured with a wall plate then a ceiling support is not needed. 15/16th Drop ceiling grid.

Use the OPTS S902 screws to attach to ceiling grid.


Special Installation Instructions Drop Ceiling Grid Mount with RECESSED tiles.

In some cases, it may be necessary to use spacers under the each swivel clip due to the use of recessed tiles. Recessed Acoustical ceiling tiles

Drop ceiling grid.

Nylon spacers are available at most home improvement stores.

Using white nylon spacers will allow the swivel clip to be installed without interfering with the recessed acoustic tiles.


Special Installation Instructions 9/16th Inch Drop Ceiling Grid Mount To install into the smaller 9/16th drop ceiling grid, be sure to line up the hanger slot with the screw holes of the swivel clip.

If the ceiling tiles are recessed, spacers will need to be used. Please refer to page 7.

Swivel Clips should be secured 24� apart. This also allows the grabber enough space to remove and replace curtains. Please remember that if the track is secured with a wall plate then a ceiling support is not needed. 9/16th Drop ceiling grid.

Use the OPTS S902-1 screws to attach to ceiling grid.


Special Installation Instructions Hard Ceiling Installation After determining location for hard ceiling mount plate, pre-drill 3/8” holes to accommodate plastic anchors. Insert anchors and secure with OPTS-S402 5/32”x1-1/4” mount screws

A laser level is very useful when laying out locations for the hard ceiling mount plates.


Installation Instructions

Mount with 11/4 inch screws and anchors.

PARTS ASSEMBLY

Mount with 3/8 inch self tapping screws.

Hard ceiling mount. Drop ceiling grid mount.

Mount track hanger with 1/8 inch set screws.

After positioning track arm on rail, secure arm to hanger with set screw.


Special Installation Instructions Hard Ceiling Installation After determining location for wall mounts, pre-drill 3/8” holes to accommodate plastic anchors. Insert anchors and secure with OPTS-S402 5/32”x1-1/4” mount screws

After the track and hanger connector has been inserted into the back of the track, slide unto the wall mount and secure with a OPTS-S102 set screw..

A laser level is very useful when laying out locations for the wall mount plates.


Installation Instructions

PARTS ASSEMBLY

Join track pieces by sliding the Track Connector into each adjoining end of track.

Once the Track Connector is in place, secure with Set Screws. SPECIAL NOTE: During the installation process it will become necessary to cut track to fit. Be sure to take care in cutting the end of the track that does not join to another track. Manufactured ends of track are ideal for joining with connector. Cut ends may be capped off at the end of the track using the End Cap or the End Wall Plate. Example:

Cut

Manufactured Cut

Manufactured


Installation Instructions

PARTS ASSEMBLY

To connect End Wall Plates* and End Caps, simply slide into place and secure with Self Tap Screw.

*Special Note: Securing the End Wall Plate with the Self Tap Screw will be the last step in the entire installation. (This does not apply to the End Cap, feel free to secure with Self Tap Screw after determining proper length of track.)

One of the final steps of installation involves placing the Hanger & Track Connector. Place the end of the H&T Connector into the groove on the back side of the Track and turn clockwise 1/4 turn. This will lock the H&T Connector into place. To reposition, simply reverse the process.

Special Note: The H&T Connector can only be turned into the track in a clockwise direction due to the tapered end.


Installation Instructions

Extensible Tubes

To connect Extensible Tube to the Ceiling Vertical Mount Plate, you may need a rubber mallet to completely insert the tube. Do this before you attach the mount plate to the ceiling. The mount plate is designed to taper so that once the tube has been completely inserted it will not flex. Be sure to insert cut end or end that does not have the manufactured hole.

Insert Hanger into Tube/Hanger Connector and secure with long set screw.

Special Note: Extensible tubes can be used to drop the rail up to 18�.

Part # set screw OPTS-S602 5/32�x13mm


Installation Instructions

“Retro Fit� Into Existing Rail

The Swivel clip can be installed directly into the existing track using the TO2 track Adapter. This track adapter is designed to fit in most rail. In some cases very thin rail will not work with the track adapter


MATERIAL

Extruded Aluminum

FINISH

White Baked Enamel

BENDS

All bends shall be between 12” and 24” radius up to 90 degrees

CONNECTORS

Extruded aluminum hangar and nylon assembly parts.

Top of Track

0174RT Track Detail OPTS-E02

OPTS-F02

Front of Track

38mm

OPTS-G02

OPTS-B02

OPTS-M02

OPTS-C02

10mm

OPTS-S02

ARCHITECT

DATE

CONTRACTOR

DATE REV

DISTRIBUTOR

DRAWN BY

PROJECT

JOB #

SHEET 174 HUDSON STREET, 4TH FLOOR, NY NEW YORK 10013 212-625-6636


Blocking Option 1

The ability to “Block� above drop ceiling to superstructure above with12 gauge taught Guy wire.

15/16th T-Bar Grid Two part clip secured with 8/32 16mm screw

Hanger set screw


Blocking Option 2

Fire rated blocking above drop ceiling. (to be provided and installed by General Contractor)

Two part clip secured to blocking with four (4) appropriate 他 inch screws (determined by blocking material).