wca E
ARCHITECT West Chin Architect, PLLC 137 Fifth Avenue, Penthouse New York, NY 10010 t. 212.242.4945 f. 212.242.9403 New York License #030214
© 2019 West Chin Architect, PLLC All design elements and visual ideas specified or illustrated within this project are the intellectual property of West Chin Architect, pllc.
CONSULTANTS MECHANICAL ENGINEER: RJD Engineering 590 Franklin Avenue, Suite 4 Nutley, NJ 07110 t. 937.661.5785
D
1 4 5 LEGEND/NOTES 1. 2.
new exposed HVAC round duct; refer to mechanical drawing
3.
±14'-6" AFF B.O. EX. CLG.
4.
+9'-0" AFF T.O. DOOR OPEN.
±7'-9 1/2"
+9'-0" AFF T.O. DOOR OPEN.
±4 1/2" to match existing
±5'-3 1/2"
C
Contractor to refer to A-020 for material schedule Contractor to protect facade during demo & construction as required Details shown schematically only and shall be verified in field by contractor for site condition and feasibility. Contractor to provide shop drawings and samples of finishes for architect & clients' approval prior to fabrication.
±10" to match existing
ADA actuator
+0'-0" AFF T.O. FIN. FL.
B
+0'-0" AFF T.O. FIN. FL. automatic door leaf
ADA actuator ±1'-9 1/2"
3'-0"
3'-0"
automatic door leaf
±1'-9 1/2"
±6'-0 3/4"
3'-0"
±10'-0" VIF
3'-0"
±12'-3 1/4" VIF
ISSUED / REVISIONS
A
1
PROPOSED FRONT ENTRY DOOR ELEVATION
A-300
2
1/2"=1'-0"
A-300
NO.
DATE
1
10.29.19
BY
DESCRIPTION issued for pricing
PROPOSED VESTIBULE DOOR ELEVATION 1/2"=1'-0"
PROJECT LOCATION 145 Hudson Street, New York, NY 10013
PROJECT NUMBER 1060
DESCRIPTION Proposed entry & vestibule doors elevations
SCALE
DATE 10.29.19
7
145 HUDSON LOBBY
6
5
4
3
2
as noted
1
not for construction - for pricing only
A-300
wca
2 A-620
1'-0"
±14'-6" AFF T.O. EX. CLG.
1'-0"
±14'-6" AFF T.O. EX. CLG.
E
new flush-mounted adjustable LED light fixture as per light fixture schedule
ARCHITECT West Chin Architect, PLLC 137 Fifth Avenue, Penthouse New York, NY 10010 t. 212.242.4945 f. 212.242.9403 New York License #030214
±14'-6" AFF T.O. EX. CLG.
knife edge detail & niche by GC
© 2019 West Chin Architect, PLLC All design elements and visual ideas specified or illustrated within this project are the intellectual property of West Chin Architect, pllc.
versa wall irrigation system by gsky; plants selection by John Mini
CONSULTANTS MECHANICAL ENGINEER: RJD Engineering 590 Franklin Avenue, Suite 4 Nutley, NJ 07110 t. 937.661.5785
12'-6" VIF
3/4'' plywood backing & wall construction by GC
D
3/4'' supply line by gsky; connection line to remote gsky nutrient injector by GC; location of nutrient injector TBD
fastener to mount 3/4'' plywood backing by GC
LEGEND/NOTES
+0'-0" AFF T.O. FIN. FL. 1'-0"
5'-7" VIF
1'-3" VIF
1'' drain line by gsky; 1'' drain pipe stub out by GC; Copper or PEX required; building drainage line by GC
1'-0"
1'-0"
existing wall to remain
+0'-0" AFF T.O. FIN. FL.
new interior walls
+0'-0" AFF T.O. FIN. FL.
C
1.
7'-7" VIF 2.
as req'd
( note: glass door not shown )
3.
4. 1 A-620
GREEN WALL FRONT ELEVATION
2
1/2"=1'-0"
A-620
SCHEMATIC SECTION
3
1/2"=1'-0"
A-620
SIDE ELEVATION
5.
1/2"=1'-0"
6.
Green wall design including irrigation system & installation by others. Contractor to coordinate with consultant buildings accordingly. Contractor to provide water drainage connections, and outlets as req'd. Contractor to provide concealed blocking / bracing as required for installation as req'd for the green wall. Contractor to provide wall construction & waterproofing of niche for the green wall as req'd. Contractor to refer to A-400 for wall assembly details. Details shown schematically only and shall be verified in field by contractor for site condition and feasibility.
3' 1'-2"
1'-10" 1'
4"
gsky timer with lock
6 3/4"
main water supply line to gsky nutrient injector by GC
B
6"
dual receptacle (120 vac; 15amp) by others
gsky 3/4" push & fit ball valve
gsky nutrient injector
5'-7" VIF
1'-3" VIF
7'-7" VIF
7 1/4"
1'-0"
gsky valve assembly (zone) water supply line from gsky nutrient injector to stub-out at green wall by GC
GREEN WALL ENLARGED PLAN 1/2"=1'-0"
4'-8"
A-620
INSPIRATION IMAGES FOR REFERENCE ONLY
A-620
N *REQUIREMENTS: *gsky nutrient injector - 7 1/4"h x 22"w x 7 1/8"d *3/4" fipt inlet / outlet *easy access for maintenance *adequate pressure to get min 40 psi at Green wall stub-out(s) *120v / 15amp gfci power receptacle *back-flow preventor as required by others (with drain) *floor drain for maintenance
3'
4
6
NOTE AS PER GSKY: If there is no drain under Green wall, a remote overflow tank and sump pump by GSKY could be installed depending on site conditions.
Recommendation as per John Mini Green wall consultant: • A suitable structure, capable of carrying the gravity weight (10 PSF) of the Versa Wall System, must be provided by others for the Versa Wall System to attach to. • Trim (if necessary) to be a Standard Maple Veneer wood white. • Backing of green wall to receive a ¾” plywood to attach system to. Final specs on existing conditions required. • Water – provide 3/4” water supply to ICU. JMDL will provide the following material but any plumbing work required to wall connection to be by others • Electric – Provide Quad outlet 120V15A GFCI at ICU • Drainage – Provide 1-1/2"drain pipe below each green wall section. • Inclusion of a floor drain below the Green Wall irrigation components is recommended for all interior walls. By not including a drain, the customer is assuming all risks associated with Green Wall water usage. • For the basic survival of the plants, a minimum of one hundred fifty (150) foot candles of light must be provided in an even flood across the entire surface of the wall for a minimum of ten to twelve (10~12) hours per day (adjustable timer) using appropriate lamps (LED or Metal Halide) with a color temperature of 4,300K. Metal Halide fixtures must be mounted at an appropriate distance from the wall to ensure even light distribution and to mitigate any heat issues (recommend 5’ distance minimum).
ISSUED / REVISIONS
A
NO. 1
DATE 10.29.19
145 Hudson Street, New York, NY 10013
PROJECT NUMBER
Plant Schedule: • Pothos • Philodendron • Dracaena • Aglaonema • Bird Nest Fern .
A-620
7
145 HUDSON LOBBY
6
5
1060
DESCRIPTION Green wall detail
SCALE
DATE
REMOTE SINGLE ZONE IRRIGATION NUTRIENT INJECTOR BY GSKY - ELEVATION
10.29.19
N. T. S.
4
DESCRIPTION issued for pricing
PROJECT LOCATION
FLOOR DRAIN
5
BY
3
2
as noted
1
not for construction - for pricing only
A-620