Online Steam Sodium Analyzer

Page 1

R

ONLINE STEAM SODIUM ANALYZER MODEL NO.- ACM-HK-358


R

ONLINE STEAM SODIUM ANALYZER The Online Steam Sodium Analyzer have been modernized record online steam sodium meters. They have been most appropriate matched for modernized industrial applications, preferred for energy plants as well as alternative associated application, granted with Professional ppb turn sodium electrode that is specifically written for cation sodium measurement. Beside being rarely correct the online sodium meters have been really low maintenance. The singular underline of the meters have been tall grade of fortitude as well as Large LCD, display. These units have been row mounted for easy operation.

Features ? Professional ppb turn sodium electrode. ? Special designmen for cation sodium measurement. ? The lowest upkeep of a analyzer. ? Large LCD display. ? The fortitude is high. ? Low upkeep consumption. ? The row ascent is easy for operating.

Technical Specifications Transmitter Data Measuring Range:

0.00∼9.36) pNa,0.01µg/L∼23.0g/L,(-1000∼+1000)mV

Min. Resolution:

0.01pNa,0.01ug/L,0.1mV

Accuracy:

0.01pNa, 1display byte, ±0.5mV(between ±10? of the calibration temperature)

Stability:

±0.01pNa/24h,±1display byte/24h,±0.5mV/24h

Current Output:

(0∼10)mA or (0∼20)mA or (4∼20)mA(two channel isolated output)

Output Precision:

±1%F.

Max. Output loading:

800Ω

Power Supply:

(220±22)VAC, (50±1)Hz


R

Power Consumption:

8W

Insulation:

Line & Neutral of power supply to earth, 1500V/1minute, no flying arc

Alarm Output

high concentration alarm、low concentration alarm、high temperature alarm、 low temperature alarm(the alarm value can be changed by program, two items in four can be set.)

Conmmunication:

CAN bus(optional)

Auto Data Record

It can record the history data, history event and calibration record automatically

Instrument Data Measuring Range:

(1.00∼8.00)pNa, 0.23ug/L~2300mg/L

Min. Resolution:

0.01pna or 0.01ug/l

Accuracy:

±0.02pna or ±0.5ug/l, the larger one (during the ±10? of the calibration temperature)

Responding Time:

reach 90% in 2 minutes at 25?

Temperature Electrode:

Pt1000 Temperature Range: Temperature Precision: Temperature Resolution: Temperature Compensation Range: (0.1∼60.0)? (automatic or manual)

Calibration:

sample and two points standard solution calibration.

Overall Dimension:

450W×690H×190Dmm(panel mounting)

Panel Cutout:

410mm×645mm

Weight:

20kg

Sample Data Temperature:

(5∼50)?

Pressure:

( 50∼300)Kpa

Flow:

(6∼40)L/H

Solid allows in sample: ≤5 um (no jelly and grease in the sample) Environment Data Ambient Temperature:

(5∼45)?

Ambient Humidity:

≤90%RH (no condensation)

Transportation Temp.:

(-25∼55)? than 0?

(the transportation temperature of the electrode should be higher


An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products

www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com

TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com

SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com

SHOWROOM J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com

SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.