Final design
Module name: Virtual project Module code: BE1341 Student number: W12033145
1
Contents Page •
Ground floor plan
3
•
Mezzanine floor plan
4
•
North and east elevation
5
•
South and west elevation
6
•
Sections
7
Detailed drawings:
8
•
Wall and floor junction
8
•
Wall and window junction
9
2
Room Schedule 2
New blockwork Construction 450mm
Number
A106
with 200mm wool insulaltion of 0.18 U-Value and plasterboard finish
1 2 3 4 5 6 7 8 9 10 11 12
9817
8380
Kit storage 62 m²
Existing stone wall Existing stone wall 480mm with internal wool insualtion providing U vlaue of 0.25
2673 3810
Meeting Room 20 m²
2790
Steel columns
Name Meeting Room Kit storage Main teaching space Entrance/Lobby Drying kit space Disabled Male W.C F-W.C Room Staff space Staff W.C Staff W.C
Area
Volume
20 m² 62 m² 71 m² 72 m² 33 m² 4 m² 9 m² 7 m² Not Placed 33 m² 4 m² 4 m²
48.27 m³ 151.79 m³ 172.10 m³ 170.58 m³ 67.06 m³ 9.75 m³ 21.55 m³ 18.22 m³ Not Placed 79.27 m³ 10.06 m³ 10.06 m³
12560
4020
5690
6270
Triple glazed gable Main teaching space 71 m²
1 A106
Entrance/Lobby 72 m²
UP
By Room Name Legend
1340 Disabled 4 m² F-W.C 7 m²
1770
Staff W.C 4 m²
Drying kit space Entrance/Lobby
Male W.C 9 m²
F-W.C Kit storage
3140
Internal wall Timber frame wall with wool insulation and plasterboard finish
Main teaching space
4285
7
6
5
4
3
Male W.C
2
Meeting Room
Level 0
Staff W.C
1 : 100 No.
Description
Date
PROJECT
CLIENT
Boulmer www.autodesk.com/revit CODE
STATUS
SUITABILITY DESCRIPTION
SHEET PURPOSE OF ISSUE
Ground floor plan
Date
Owner Project number
30/03/2014
Project Number
Drawn by
DRWAING NUMBER
Adam Husseini Checked by
Checker
A101
Scale (@ A3)
1 : 100 REV
08/04/2014 17:08:12
1
Disabled
Drying kit space 33 m²
Staff W.C 4 m²
Room Schedule
2 A106
Number
Timber suspended floor Attached by the use of steel bolts and joist hangers 8770
Meeting Room Kit storage Main teaching space Entrance/Lobby Drying kit space Disabled Male W.C F-W.C Room Staff space Staff W.C Staff W.C
Area
Volume
20 m² 62 m² 71 m² 72 m² 33 m² 4 m² 9 m² 7 m² Not Placed 33 m² 4 m² 4 m²
48.27 m³ 151.79 m³ 172.10 m³ 170.58 m³ 67.06 m³ 9.75 m³ 21.55 m³ 18.22 m³ Not Placed 79.27 m³ 10.06 m³ 10.06 m³
1 A106
5533
Staff space 33 m²
1 2 3 4 5 6 7 8 9 10 11 12
Name
5141 DN
Level 1
6
5
4
3
By Room Name Legend
2
Staff space
1 : 100 No.
Description
Date
PROJECT
CLIENT
Boulmer www.autodesk.com/revit CODE
STATUS
SUITABILITY DESCRIPTION
SHEET PURPOSE OF ISSUE
Mezzanine floor
Date
Owner Project number
30/03/2014
Project Number
Drawn by
DRWAING NUMBER
Adam Husseini Checked by
Checker
A107
Scale (@ A3)
1 : 100 REV
08/04/2014 17:28:24
1
7
Roof level 7520
2890
Level 6
Level 2
Level 4
2270
2820
2554
2254
3510
1
East 1 : 100 Roof level 7520 343500
372425 855
2527
2673
2417
1000
Level 1
2554
2500 2500
Level 2
Level 0 0
No.
Description
North elevation 1 : 100
Date
PROJECT
CLIENT
Boulmer www.autodesk.com/revit CODE
STATUS
SUITABILITY DESCRIPTION
SHEET PURPOSE OF ISSUE
East elevation
Date
Owner Project number
30/03/2014
Project Number
Drawn by
DRWAING NUMBER
Author Checked by
Checker
N & E elevations
Scale (@ A3)
1 : 100 REV
18/04/2014 19:10:45
2
Roof level 7520
8790
4285
2792
1558
11164
Level 1 2500
Level 0 0
South
1
1 : 100
Roof level 7520
1190
1810
1860
4790
3810
2716
Level 5 3600
Level 1 2500
Level 6 2820
Level 0 0
No.
Description
West 1 : 100
Date
PROJECT
CLIENT
Boulmer www.autodesk.com/revit CODE
STATUS
SUITABILITY DESCRIPTION
SHEET PURPOSE OF ISSUE
South&West elevation
Date
Owner Project number
30/03/2014
Project Number
Drawn by
DRWAING NUMBER
Adam Husseini Checked by
Checker
A104
Scale (@ A3)
1 : 100 REV
18/04/2014 18:57:40
2
6011
2527
937
400
Roof level 7520 290
12430
2792
Level 2 2554
1
Section A-A 1 : 100 Roof level 7520
Level 1 2500
Level 0 0 493
No.
493
5684
Section B-B 1 : 100
Description
Date
PROJECT
CLIENT
Boulmer www.autodesk.com/revit CODE
STATUS
SUITABILITY DESCRIPTION
SHEET PURPOSE OF ISSUE
Sections
Date
Owner Project number
30/03/2014
Project Number
Drawn by
DRWAING NUMBER
Adam Husseini Checked by
Checker
A106
Scale (@ A3)
1 : 100 REV
01/04/2014 20:36:18
2
3185