969syv38n9ph8m9v

Page 1

Committing to the future

The Digital Headstart for Refrigeration Engineers! testo 523, 556, 560 Precision and assurance with the new generation of digital refrigeration system analyzers

NEW!


1

Precision - the basis for perfect results Highly accurate pressure and temperature sensors The use of digital measurement technology with highly accurate sensors sets new standards in precision and assurance of measurement. The accuracy of the analyzers is +/- 0.5% fs + 1 digit. This provides assurance in day-to-day working, and forms the basis for the refrigeration engineers’s proof of quality. Digital display The digital display guarantees that readout errors are eliminated in the future. The risk of inaccuracy in reading analog displays is always present, caused by the so-called parallax error, i.e.the respective angle of sight has an effect on the result read. Frequent vibrations can also make reading the display additionally difficult.


2

Indestructible in tough applications Practice in a multitude of applications show that the instruments are placed under a great deal of strain during transport and on site. For this reason, the new digitial refrigeration system analyzers are put through extreme endurance tests. Among these are drop tests (the instrument must not only be undamaged, but also work faultlessly, after a fall from a height of 1.5 m onto a concrete floor).

1

The second skin made of shockabsorbent material protects from mechanical damage.

2

The valves can be stowed, avoiding damage from shearing forces.

1

Vibration tests according to DIN/EN 50379 guarantee the functionality of the construction far beyond the demands of dayto-day use. 2

The IP54 protection class documents the resistance towards splash-water. However, there is no substitute for practice: years of experience as a pioneer in the field of digital refrigeration system analyzers, and countless field tests with users, show that tough conditions are no problem for the new generation of measuring instruments.


3

Highly versatile and user-friendly 30 refrigerants integrated in the instrument optimum refrigerant management The temperature/pressure curves of 30 refrigerants are stored in the instrument. If other refrigerants are required, they can be downloaded free of charge fromm the Testo website and transferred to the instrument. This makes the refrigeration system extremely versatile for all systems and requirements. Versatility with wireless probes With testo 556 and 560, wireless measurement at distances of up to 20 m (without obstruction) are possible, in addition to measurements with classical probes. A selection: pipe wrap probes, immersion, penetration and air probes allow the measurement of different media and objects. Damage to the probe cable or hindrances in use are thus eliminated.

Superheating/subcooling are calculated in real time. Evacuation with the display of the evaporation temperature of water During the evacuation of a system, the integrated vacuum sensor (testo 560) measures the absolute pressure and the evaporation temperature of water. The measured values provide information on whether the system is being optimally dried, i.e whether the water vapour is being withdrawn. The evacuation can be carried out considerably quicker than has been possible up to now. Easy to operate Easily comprehensible, clear and practice-oriented menu structures allow fast and intuitive operation. The large backlit display and the sight glass guarantee good handling even in dark surroundings. Practical accessories can be easily connected, and operated via the instrument.


4

Security for data and instrument Theft protection The instruments can be secured against theft with a padlock. Data protection A code prevents unauthorized termination of the measurement. The data are manipulation-proof and can therefore be used as proof.


5

Fast and easy documentation Data store with report printout The data store in the instruments testo 556 and testo 560 allows easy and fast documentation of the measurement results. Stored values can be effortlessly logged with the help of the software EasyKool. Company logos can be integrated in the reports. All analyzers additionally have the possibility of printing readings on the Testo infrared report printer. Easy refrigerant inventory management according to the F-gas regulation The filling or refilling of a system can be documented. The quantities are stored in the instrument.


6

Software Software „EasyKool“ Readings can be displayed graphically or in tabular form with the software EasyKool. A commissioning report can be created if all actions taken during commissioning are recorded. The uninterrupted documentation of the data over a defined period allows the targeted diagnosis of the causes of malfunctions. The commissioning data as well as all inspection data are available at all times. This makes all interference with the system - including unauthorized interference - transparent. The data are manipulation-proof. The use of the measurement system, (instrument and software), thus not only helps to be more accurate and considerably faster, it also increases customer satisfaction, as all relevant data are available.


An overview testo 523

testo 556

testo 560

The starting instrument for service and maintenance

The professional solution for service and maintenance

testo 523 is suitable for service and maintenance on air conditioning and refrigeration systems, and heat pumps:

testo 556 is suitable for service and maintenance on air conditioning, refrigeration systems and heat pumps, with extended professional documentation option.

The professional solution for commissioning, service and maintenance

Printout on site with Testo report printer (optional). High quality sensors measure high and low pressure and temperature. Pressure probes temperature-compensated Calculation of superheating/subcooling in real time.

Additionally to testo 523 · 4-way valve block with sight glass · 4 temperature probe connections · Wireless temperature measurement up to 20 m distance (without obstruction) · 30 refrigerants, updatable via internet free of charge

Display and sight glass illumination · 2-way valve block with sight glass · 1 temperature probe connection

testo 560 with a vacuum measuring cell is suitable for system evacuations. Commissioning can also be carried out with it. Additionally to testo 523 and 556: · Vacuum sensor/evacuation · The sensor measures the absolute pressure and displays the corresponding evaporation temperature of water. · The vacuum cell is protected from high pressures by a special valve.

· 60,000 readings can be stored use of software EasyKool (optional) · Extensive range of accessories can be connected

· 30 refrigerants are stored in the instrument testo 556-1

testo 560-1

The refrigeration system analyzer for service and maintenance, incl. calibration protocol and batteries

The refrigeration system analyzer for service, maintenance and commissioning, incl. calibration protocol and batteries

Order no. 0560 5563

Order no. 0560 5603

testo 523

testo 556-2

testo 560-2

The refrigeration system analyzer for service and maintenance, incl. calibration protocol and batteries

The refrigeration system analyzer for service and maintenance, incl. calibration protocol and batteries, stainless steel version for NH3

The refrigeration system analyzer for service and maintenance, incl. calibration protocol and batteries, stainless steel version for NH3

Order no. 0560 5231

Order no. 0560 5564

Order no. 0560 5604


Technical data

testo 523

testo 556

testo 560

Operating temperature

-20°C to + 60°C

Storage temperature

-20°C to + 60°C LCD

Display Battery life

40h (without illumination)

Dimensions

260 x 130 x 70 mm

Weight

1250 g

1400 g

Pressure media

CFC, HFC, N, H2O, CO2,- 2 stainless steel versions: NH3

Protection class

IP 54

Low pressure (LP) High pressure (HP)

25/50 barrel

Overload (LP/HP)

40/100 bar

Saves a lot of trouble!

± 0.5% of full scale value ± 1 digit (Class 0.5)

Accuracy Connections

3x7/16“ – UNF

3x7/16“ – UNF+1x 5/8“ – UNF

Vacuum

0 to 200hPaabs

Overload vacuum

3bar/sensor protected from high pressures

Temperature - 50 to + 200°C

Measuring range Accuracy

Pt 100 class B ± (0.3 + 0.005 tl) 0.1 °C

Resolution Probe connections

1x plug-in

Refrigerants in the instrument

30

2x plug-in and 2x wireless 30 (further refrigerants can be downloaded free of charge from the Testo homepage using the software)

Refrigerants in the instrument: R12 R 401A R 404A R 408A R422a* R 1270 R 401B R 406a* R 409A R500 R 134a R 401C R 407A R 410A R502 R 22

R 402A R 407B R 413A R507 R 23 R 402B R 407C R 414b* R718 R 290 R 403B R 407D R 417A R744 R 508** R 717** R 723**

Documentation

Data store in instrument

* in –1 version only (brass) / ** in –2 version only (stainless steel)

IR printer

Printer –

60,000 readings


Accessories

Accessories for all instruments

Order no.

Testo report printer with wireless IRDA and infrared interface, 1 roll thermal paper and 4 AA batteries Spare thermal paper for printer (6 rolls), long-term legible measurement data documentation up to 10 years Padlock for securing instrument External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries, with single cell charging and charge control display, incl. impulse trickle charging, discharge function, with internat. mains plug, 100-240 V, 300 mA, 50/60 Hz Transport case for measuring instrument and accessories System case for measuring instrument and extended accessories

0554 0547 0554 0568 0554 1747 0554 0610 0516 5013 0516 5602

Calibration certificates

Order no.

ISO Calibration certificate relative pressure, 3 measurement points spread over measurement range ISO Calibration certificate absolute pressure, 3 measurement points spread over measurement range ISO Calibration certificate surface temperature, measurement points: +60/+120/+180 °C ISO Calibration certificate air/immersion temperature, measurement points: -18/0/+60 °C ISO Calibration certificate surface temperature in refrigerator, measurement points: -18/0/+60 °C

0520 0085 0520 0185 0520 0071 0520 0001 0520 0151

Note: calibration certificates are valid only for one sensor

Probes

Illustration

Pipe wrap probe with Velcro tape for pipes from Ø 6 mm to Ø 120 mm, Pt100, 2.9 m cable length

Robust, waterproof immersion/penetration probe

280 mm

t99

Meas. range

Accuracy

-50 to +120 °C

Class B

-50 to +400 °C

Class A

12 sec

0609 1273

-50 to +200 °C

Class B

40 sec

0609 1973

-50 to +400 °C

Class A

70 sec

0609 1773

-50 to +120 °C

Class B

5 sec

0609 5605

Order no. 0609 5602

20 mm

Fixed cable 1.2 m

114 mm

50 mm

Ø 5 mm

Ø 3.7 mm

114 mm

Robust, waterproof surface temperature probe, Pt 100

Ø 5 mm

Ø 9 mm

Fixed cable 1.2 m

Robust air probe Fixed cable 1.2 m

Pipe wrap probe for pipe diameters 5 to 65 mm

114 mm

50 mm

Ø 5 mm

Ø 4 mm

Fixed cable

Accessories for testo 556 and testo 560 Mains unit, 5 VDC 500 mA with multi-standard plug USB data transfer cable, instrument – PC Software „EasyKool“ with measurement data management, incl. USB data cable Stainless steel adapter for NH3 (ammonia), 3 connection hoses 7/16” to 1/2” and 1 connection hose from 5/8" to 1/2”, hose length 24 cm

Order no. 0554 0447 0449 0047 0554 5604 0554 5561


Radio module for upgrading measuring instrument with radio option Country versions

Radio frequency

Order no.

Radio module for measuring instrument, 869.85 MHz, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

869.85 MHz FSK

0554 0188

Radio module for measuring instrument, 915.00 MHz FSK, approval for USA, CA, CL

915.00 MHz FSK

0554 0190

Radio probes for immersion/penetration measurements Immersion/penetration probes Immersion/penetration probe, NTC

105 mm

30 mm

Ø 5 mm

Ø 3.4 mm

Meas. range

Accuracy

Resolution

t99

-50 ... +275 °C

±0.5 °C (-20 to +80 °C) ±0.8 °C (-50 to -20.1 °C) ±0.8 °C (+80.1 to +200 °C) ±1.5 °C (remaining range)

0.1 °C

t99 (in water) 12 sec

Country versions

Radio frequency

Order no.

Wireless immersion/penetration probe, NTC, approval for the countries DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

869.85 MHz FSK

0613 1001

Wireless immersion/penetration probe, NTC, adapter, approval for USA, CA, CL

915.00 MHz FSK

0613 1002

Assembled for you: radio handles with probe head Radio handles incl. probe head for air/immersion/penetration measurements Radio handle for plug-in probe heads with TC probe head for air/immersion/penetration measurements

100 mm

30 mm

Ø 5 mm

Ø 3.4 mm

Meas. range

Accuracy

Resolution

t99

-50 to +350 °C short term to +500 °C

Radio handle: ±(0.5 °C +0.3% of m.v.) (-40 to +500 °C) ±(0.7 °C +0.5% of m.v.) (remaining range) TC probe head: Class 2

0.1 °C (-50 to +199.9 °C) 1.0 °C (remaining range)

t99 (in water) 10 sec

Country versions

Radio frequency

Order no.

Radio handle for plug-in probe heads, incl. TC adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

869.85 MHz FSK

0554 0189

TC probe head for air/immersion/penetration measurement, attachable to radio handle, TC Type K

0602 0293 915.00 MHz FSK

Radio handle for plug-in probe heads, incl. TC adapter, approval for USA, CA, CL

0554 0191

TC probe head for air/immersion/penetration measurements,plugs onto radio handle, TC Type K

0602 0293

Radio handles incl. probe head for surface measurements 120 mm

Radio handle for plug-in probe heads with TC probe head for surface measurments

Ø 5 mm

40 mm

Meas. range

Accuracy

Resolution

t99

-50 to +350 °C short term to +500 °C

Radio handle ±(0.5 °C +0.3% of m.v.) (-40 to +500 °C) ±(0.7 °C +0.5% of m.v.) (remaining range) TC probe head: Class 2

0.1 °C (-50 to +199.9 °C) 1.0 °C (remaining range)

5 sec

Ø 12 mm

Country versions

Radio frequency

Order no.

Radio handle for plug-in probe heads, incl. TC adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

869.85 MHz FSK

0554 0189

TC probe head for surface measurement, attachable to radio handle, TC Type K

0602 0394

Radio handle for plug-in probe heads, incl. TC adapter, approval for USA, CA, CL

915.00 MHz FSK

0554 0191

TC probe head for surface measurement, attachable to radio handle, TC Type K

0602 0394

Separate radio handles Radio handles for plug-in TC probes Radio handles for plug-in probe heads incl. adapter for connecting (Type K)

Meas. range

Accuracy

Resolution

-50 to +1000 °C

±(0.7 °C +0.3% of m.v.) (-40 to +900 °C) ±(0.9 °C +0.5% of m.v.) (remaining range)

0.1 °C (-50 to +199.9 °C) 1.0 °C (remaining range)

Country versions

Radio frequency

Order no.

Radio handle for plug-in probe heads, incl. TC adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO

869.85 MHz FSK

0554 0189

Radio handle for plug-in probe heads, incl. TC adapter, approval for USA, CA, CL

915.00 MHz FSK

0554 0191

Radio probes: general technical data Probe type

Wireles immersion/penetration probe NTC

Radio handle

Battery type

2 x 3V button cell (CR 2032)

2 AAA

Battery life

150 h (meas. rate 0.5 sec) 2 months (meas. rate 10 sec)

215 h (meas. rate 0.5 sec) 1/2 year (meas. rate 10 sec)

Fühler für Funkhandgriff

115 mm

Efficient, waterproof surface probe with small measurement head for flat surfaces, TC Type K

150 mm

Ø 5 mm

Ø 2.5 mm

Pipe wrap probe with Velcro strip, for temperature measurement on pipes with diameter up to max. 120 mm, Tmax +120°C, TC Type K

Radio range

up to 20 m (without obstruction)

Radio ransmission

unidirectional

Oper. temp.

-20 to +50 °C

Storage temp.

-40 to +70 °C

Meas. range

Accuracy

t99

-60 to +300 °C

Class 2

3 sec

Order no. 0602 0393 Conn.: fixed cable1,2 m

Ø 12 mm

-60 to +1000 °C

Class 1

20 sec

0602 0693

-50 to +120 °C

Class 1

90 sec

0628 0020

-60 to +130 °C

Class 2

5 sec

0602 4592

-60 to +130 °C

Class 2

5 sec

0602 0092

-50 to +100 °C

Class 2

5 sec

0602 4692

Ø 4 mm

395 mm 20 mm

Pipe wrap probe for pipe diameter 5 to 65 mm, with exchangeable measuring head. TC Type K

15 mm

35 mm

Clamp probe for measurements on pipes, pipe diameter 15 to 25 mm (max. 1"), meas. range short-term up to +130°C, TC Type K

0.5 sec or 10 sec, adjustable on handle

Illustration

Fast-action surface probe with sprung thermocouple strip, also for uneven surfaces, measurement range short-term to +500°C, TC Type K

Spare meas. head for pipe wrap probe, TC Type K

Meas. rate


路 50 YEARS

OF TESTO

路 More innovative than ever 路 50 innovations in the anniversary year

I N N O VAT I O N 2 0 0 7

The sets

Starter set testo 523-1 for service and maintenance Measuring instrument and Velcro surface probe without case

Order no. 0563 5234 Measuring instrument and Velcro surface probe incl. transport case

Order no. 0563 5235

Set testo 556-1 for service and maintenance Measuring instrument and Velcro surface probe, software, mains unit, USB data cable, lock, system case

Order no. 0563 5561

Set testo 556-2 for service and maintenance Measuring instrument with stainless steel connections, Velcro surface probe software, mains unit, USB data cable, lock, NH3 adapter, system case

Set testo 560-1 for service, maintenance and commissioning Measuring instrument and Velcro surface probe, software, mains unit, USB data cable, lock, system case

Subject to change without notice

Order no. 0563 5562

Set testo 560-2 for service, maintenance and commissioning Measuring instrument with stainless steel connections, Velcro surface probe software, mains unit, USB data cable, lock, NH3 adapter, system case

Order no. 0563 5603

www.testo.com

0981 3564/msp/R/Q/02.2007

Order no. 0563 5602


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.